• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4624131)   Today's Articles (6046)   Subscriber (49410)
For: Att W, Komine F, Gerds T, Strub JR. Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses. J Prosthet Dent 2009;101:239-47. [PMID: 19328277 DOI: 10.1016/s0022-3913(09)60047-0] [Citation(s) in RCA: 78] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Number Cited by Other Article(s)
1
Chang MC, Cheng LW, Chuang SF, Chen YC. The influence of pontic distribution on the marginal and internal gaps of CAD/CAM five-unit anterior zirconia framework. J Dent Sci 2024;19:1105-1115. [PMID: 38618091 PMCID: PMC11010717 DOI: 10.1016/j.jds.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/12/2023] [Indexed: 04/16/2024]  Open
2
Lopez D, Ziada H, Abubakr NH. Influence of thermal aging on the marginal integrity of computer aided design/computer aided manufacturing fabricated crowns. J Dent Sci 2024;19:971-977. [PMID: 38618116 PMCID: PMC11010792 DOI: 10.1016/j.jds.2023.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/07/2023] [Indexed: 04/16/2024]  Open
3
Temizkan Nizaroglu R, Küçük C. Evaluation of Marginal and Internal Adaptation of Crowns Fabricated with Three Different Zirconia CAD/CAM Materials. Niger J Clin Pract 2024;27:54-61. [PMID: 38317035 DOI: 10.4103/njcp.njcp_410_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 11/09/2023] [Indexed: 02/07/2024]
4
Nasir MQ, kadhim AJ. Marginal adaptation of different monolithic zirconia crowns with horizontal and vertical finish lines: A comparative in vitro study. J Dent Res Dent Clin Dent Prospects 2023;17:235-241. [PMID: 38584994 PMCID: PMC10998165 DOI: 10.34172/joddd.2023.40589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 10/25/2023] [Indexed: 04/09/2024]  Open
5
Althaqafi KA. Performance of direct and indirect onlay restorations for structurally compromised teeth. J Prosthet Dent 2023:S0022-3913(23)00549-8. [PMID: 37696748 DOI: 10.1016/j.prosdent.2023.07.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 07/21/2023] [Accepted: 07/21/2023] [Indexed: 09/13/2023]
6
Emam M, Metwally MF. Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering. BMC Oral Health 2023;23:546. [PMID: 37559037 PMCID: PMC10413631 DOI: 10.1186/s12903-023-03247-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 07/21/2023] [Indexed: 08/11/2023]  Open
7
Attia MA, Blunt L, Bills P, Tawfik A, Radawn M. Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns. J Prosthet Dent 2023:S0022-3913(23)00183-X. [PMID: 37072286 DOI: 10.1016/j.prosdent.2023.03.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/18/2023] [Accepted: 03/20/2023] [Indexed: 04/20/2023]
8
Mostafa ARA, Kotb SN, El-Shihy OAH. Internal Adaptation and Marginal Accuracy of Two Different Techniques-based Poly (ether ether ketone) Single Crowns: An In Vitro Study. J Contemp Dent Pract 2023;23:1106-1110. [PMID: 37073933 DOI: 10.5005/jp-journals-10024-3429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2023]
9
Ceylan G, Emir F. Evaluating the accuracy of CAD/CAM optimized stones compared to conventional type IV stones. PLoS One 2023;18:e0282509. [PMID: 36877717 PMCID: PMC9987827 DOI: 10.1371/journal.pone.0282509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 02/16/2023] [Indexed: 03/07/2023]  Open
10
Kim YK, Han JS, Yoon HI. Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing. J Adv Prosthodont 2022;14:122-132. [PMID: 35601347 PMCID: PMC9095451 DOI: 10.4047/jap.2022.14.2.122] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 03/15/2022] [Accepted: 03/17/2022] [Indexed: 11/08/2022]  Open
11
Morsy N, El Kateb M, Azer A, Fathalla S. Fit of zirconia fixed partial dentures fabricated from conventional impressions and digital scans: A systematic review and meta-analysis. J Prosthet Dent 2021:S0022-3913(21)00496-0. [PMID: 34696907 DOI: 10.1016/j.prosdent.2021.08.025] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 08/20/2021] [Accepted: 08/23/2021] [Indexed: 10/20/2022]
12
Belgin HB, Kale E, Özçelik TB, Yilmaz B. Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study. Odontology 2021;110:339-348. [PMID: 34665345 DOI: 10.1007/s10266-021-00668-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 10/12/2021] [Indexed: 11/30/2022]
13
Freire Y, Gonzalo E, Lopez-Suarez C, Pelaez J, Suarez MJ. Evaluation of the marginal fit of monolithic crowns fabricated by direct and indirect digitization. J Prosthodont Res 2021;65:291-297. [PMID: 33041277 DOI: 10.2186/jpr.jpr_d_20_00003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
14
Kayikci O, Ates SM. Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems. Clin Oral Investig 2021;26:1283-1291. [PMID: 34331593 DOI: 10.1007/s00784-021-04102-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 07/23/2021] [Indexed: 11/25/2022]
15
Villias AA, Kourtis SG, Karkazis HC, Polyzois GL. In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns. Int J Implant Dent 2021;7:12. [PMID: 33585971 PMCID: PMC7882652 DOI: 10.1186/s40729-021-00290-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Accepted: 01/20/2021] [Indexed: 11/10/2022]  Open
16
Al-Aali KA, Bin-Shuwaish MS, Alhenaki AM, Al Ahdal K, Al Deeb L, Maawadh AM, AlHelal A, Alshehri H, Vohra F, Abduljabbar T. Influence of milling systems and marginal configurations on the fit of yttrium stabilized tetragonal zirconia polycrystals (Y-TZP)' copings. J Appl Biomater Funct Mater 2020;18:2280800020924514. [PMID: 33356766 DOI: 10.1177/2280800020924514] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]  Open
17
Al-Aali KA, Alhamdan RS, Maawadh AM, Vohra F, Abduljabbar T. Influence of contemporary CAD-CAM milling systems on the fit and adaptation of partially stabilized Zirconia fixed partial dentures. Pak J Med Sci 2020;37:45-51. [PMID: 33437249 PMCID: PMC7794152 DOI: 10.12669/pjms.37.1.3490] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]  Open
18
Effect of cementation and aging on the marginal fit of veneered and monolithic zirconia and metal-ceramic CAD-CAM crowns. J Prosthet Dent 2020;125:323.e1-323.e7. [PMID: 33176924 DOI: 10.1016/j.prosdent.2020.06.036] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 06/21/2020] [Accepted: 06/22/2020] [Indexed: 10/23/2022]
19
Emir F, Ayyildiz S. Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies: a three-dimensional analysis. J Prosthodont Res 2020;65:365-370. [PMID: 33177305 DOI: 10.2186/jpr.jpor_2019_579] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
20
Rues S, Stober T, Bargum T, Rammelsberg P, Zenthöfer A. Disposable plastic trays and their effect on polyether and vinyl polysiloxane impression accuracy-an in vitro study. Clin Oral Investig 2020;25:1475-1484. [PMID: 32885321 PMCID: PMC7878258 DOI: 10.1007/s00784-020-03455-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 07/08/2020] [Indexed: 11/24/2022]
21
Effect of different fabrication techniques on the marginal precision of polyetheretherketone single-crown copings. J Prosthet Dent 2020;124:565.e1-565.e7. [PMID: 32636071 DOI: 10.1016/j.prosdent.2020.04.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 04/10/2020] [Accepted: 04/10/2020] [Indexed: 11/20/2022]
22
Hasanzade M, Koulivand S, Moslemian N, Alikhasi M. Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations. J Adv Prosthodont 2020;12:173-180. [PMID: 32601537 PMCID: PMC7314633 DOI: 10.4047/jap.2020.12.3.173] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 04/07/2020] [Accepted: 04/29/2020] [Indexed: 11/08/2022]  Open
23
Neto CF, Santos GC, Santos MJMC. Influence of the Fabrication Technique on the Marginal and Internal Adaptation of Ceramic Onlays. Oper Dent 2020;45:163-172. [DOI: 10.2341/19-014-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
24
García-Martínez I, CáceresMonllor D, Solaberrieta E, Ferreiroa A, Pradíes G. Accuracy of digitization obtained from scannable and nonscannable elastomeric impression materials. J Prosthet Dent 2020;125:300-306. [PMID: 32089364 DOI: 10.1016/j.prosdent.2020.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 12/09/2019] [Accepted: 01/21/2020] [Indexed: 10/25/2022]
25
Chiu A, Chen YW, Hayashi J, Sadr A. Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters. SENSORS 2020;20:s20041157. [PMID: 32093174 PMCID: PMC7071446 DOI: 10.3390/s20041157] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 02/15/2020] [Accepted: 02/17/2020] [Indexed: 11/29/2022]
26
Kwong B, Dudley J. A comparison of the marginal gaps of lithium disilicate crowns fabricated by two different intraoral scanners. Aust Dent J 2020;65:150-157. [PMID: 32037559 DOI: 10.1111/adj.12748] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/06/2020] [Indexed: 11/28/2022]
27
Alikhasi M, Ameri N, Siadat H, Shamshiri AR, Nejati M. Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering. Front Dent 2019;16:194-205. [PMID: 31858085 PMCID: PMC6911669 DOI: 10.18502/fid.v16i3.1591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Accepted: 11/03/2018] [Indexed: 11/26/2022]  Open
28
Bousnaki M, Chatziparaskeva M, Bakopoulou A, Pissiotis A, Koidis P. Variables affecting the fit of zirconia fixed partial dentures: A systematic review. J Prosthet Dent 2019;123:686-692.e8. [PMID: 31703922 DOI: 10.1016/j.prosdent.2019.06.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 06/02/2019] [Accepted: 06/03/2019] [Indexed: 10/25/2022]
29
Al Maaz A, Thompson GA, Drago C, An H, Berzins D. Effect of finish line design and metal alloy on the marginal and internal gaps of selective laser melting printed copings. J Prosthet Dent 2019;122:143-151. [PMID: 30948295 DOI: 10.1016/j.prosdent.2019.02.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Revised: 02/07/2019] [Accepted: 02/07/2019] [Indexed: 10/27/2022]
30
Dolev E, Bitterman Y, Meirowitz A. Comparison of marginal fit between CAD-CAM and hot-press lithium disilicate crowns. J Prosthet Dent 2019;121:124-128. [DOI: 10.1016/j.prosdent.2018.03.035] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2017] [Revised: 03/26/2018] [Accepted: 03/26/2018] [Indexed: 10/28/2022]
31
Kim MW, Kim JY, Shim JS, Kim S. Effect of the number of splinted abutments on the accuracy of zirconia copings. J Prosthet Dent 2018;120:790.e1-790.e7. [DOI: 10.1016/j.prosdent.2018.07.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Revised: 07/23/2018] [Accepted: 07/23/2018] [Indexed: 10/27/2022]
32
Micro-CT Analysis of Y-TZP Copings Made by Different CAD/CAM Systems: Marginal and Internal Fit. Int J Dent 2018;2018:5189767. [PMID: 30254675 PMCID: PMC6145157 DOI: 10.1155/2018/5189767] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 07/05/2018] [Accepted: 08/01/2018] [Indexed: 11/17/2022]  Open
33
Edwards Rezende CE, Sanches Borges AF, Macedo RM, Rubo JH, Griggs JA. Dimensional changes from the sintering process and fit of Y-TZP copings: Micro-CT analysis. Dent Mater 2017;33:e405-e413. [DOI: 10.1016/j.dental.2017.08.191] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Revised: 07/19/2017] [Accepted: 08/31/2017] [Indexed: 11/29/2022]
34
Lee H, Lee DH, Lee KB. In vitro evaluation methods on adaptation of fixed dental prosthesis. ACTA ACUST UNITED AC 2017. [DOI: 10.14368/jdras.2017.33.2.63] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
35
Ates SM, Yesil Duymus Z, Caglar I, Hologlu B. The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings. Clin Oral Investig 2017;21:2553-2560. [PMID: 28091875 DOI: 10.1007/s00784-017-2054-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 01/09/2017] [Indexed: 10/20/2022]
36
Digital approach to assessing the 3-dimensional misfit of fixed dental prostheses. J Prosthet Dent 2016;116:836-839. [PMID: 27460325 DOI: 10.1016/j.prosdent.2016.05.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 04/29/2016] [Accepted: 05/06/2016] [Indexed: 11/21/2022]
37
Jianming Y, Ying T, Feng P, Weixing X. [Comparative evaluation of the marginal accuracy of single crowns fabricated computer using aided design/computer aided manufacturing methods, self-curing resin and Luxatemp]. HUA XI KOU QIANG YI XUE ZA ZHI = HUAXI KOUQIANG YIXUE ZAZHI = WEST CHINA JOURNAL OF STOMATOLOGY 2016;34:575-578. [PMID: 28318156 DOI: 10.7518/hxkq.2016.06.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
38
Kale E, Seker E, Yilmaz B, Özcelik TB. Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J Prosthet Dent 2016;116:890-895. [DOI: 10.1016/j.prosdent.2016.05.006] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Revised: 05/03/2016] [Accepted: 05/04/2016] [Indexed: 10/21/2022]
39
Emir F, Piskin B, Sipahi C. Effect of dental technician disparities on the 3-dimensional accuracy of definitive casts. J Prosthet Dent 2016;117:410-418. [PMID: 27677213 DOI: 10.1016/j.prosdent.2016.06.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Revised: 06/22/2016] [Accepted: 06/22/2016] [Indexed: 10/20/2022]
40
Rani S, Verma M, Gill S, Gupta R. Comparative evaluation of bonding strength of computer aided machined ceramic, pressable ceramic, and milled metal implant abutment copings and effect of surface conditioning on bonding strength: An in vitro study. J Indian Prosthodont Soc 2016;16:142-7. [PMID: 27141163 PMCID: PMC4837770 DOI: 10.4103/0972-4052.176517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]  Open
41
Ates SM, Yesil Duymus Z. Influence of Tooth Preparation Design on Fitting Accuracy of CAD-CAM Based Restorations. J ESTHET RESTOR DENT 2016;28:238-46. [PMID: 27061751 DOI: 10.1111/jerd.12208] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
42
Rajan BN, Jayaraman S, Kandhasamy B, Rajakumaran I. Evaluation of marginal fit and internal adaptation of zirconia copings fabricated by two CAD - CAM systems: An in vitro study. J Indian Prosthodont Soc 2016;15:173-8. [PMID: 26929507 PMCID: PMC4762301 DOI: 10.4103/0972-4052.159970] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]  Open
43
Neppelenbroek KH. The clinical challenge of achieving marginal adaptation in direct and indirect restorations. J Appl Oral Sci 2015;23:448-9. [PMID: 26537713 PMCID: PMC4621935 DOI: 10.1590/1678-77572015ed005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]  Open
44
Bayramoğlu E, Kulak Özkan Y, Yildiz C. Comparison of marginal and internal fit of press-on-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study. J Prosthet Dent 2015;114:52-8. [DOI: 10.1016/j.prosdent.2015.01.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Revised: 01/12/2015] [Accepted: 01/14/2015] [Indexed: 11/29/2022]
45
El-Dessouky R, Salama M, Shakal M, Korsel A. Marginal adaptation of CAD/CAM zirconia-based crown during fabrication steps. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.tdj.2014.12.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
46
Karaman T, Ulku SZ, Zengingul AI, Guven S, Eratilla V, Sumer E. Evaluation and comparison of the marginal adaptation of two different substructure materials. J Adv Prosthodont 2015;7:257-63. [PMID: 26140178 PMCID: PMC4486622 DOI: 10.4047/jap.2015.7.3.257] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Revised: 03/16/2015] [Accepted: 04/07/2015] [Indexed: 11/25/2022]  Open
47
Habib SR, Asiri W, Hefne MJ. Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings. J Adv Prosthodont 2014;6:444-50. [PMID: 25551003 PMCID: PMC4279041 DOI: 10.4047/jap.2014.6.6.444] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2014] [Revised: 09/04/2014] [Accepted: 10/07/2014] [Indexed: 11/16/2022]  Open
48
Demir N, Ozturk AN, Malkoc MA. Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique. Eur J Dent 2014;8:437-444. [PMID: 25512721 PMCID: PMC4253096 DOI: 10.4103/1305-7456.143612] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
49
Lins L, Bemfica V, Queiroz C, Canabarro A. In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings. J Prosthet Dent 2014;113:205-11. [PMID: 25453562 DOI: 10.1016/j.prosdent.2014.09.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2014] [Revised: 09/15/2014] [Accepted: 09/15/2014] [Indexed: 11/30/2022]
50
Abduo J. Fit of CAD/CAM Implant Frameworks: A Comprehensive Review. J ORAL IMPLANTOL 2014;40:758-66. [DOI: 10.1563/aaid-joi-d-12-00117] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
PrevPage 1 of 2 12Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA