1
|
Hatoum H, Maureira P, Dasi LP. A turbulence in vitro assessment of On-X and St Jude Medical prostheses. J Thorac Cardiovasc Surg 2019; 159:88-97. [PMID: 30905419 PMCID: PMC6703975 DOI: 10.1016/j.jtcvs.2019.02.046] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 01/17/2019] [Accepted: 02/09/2019] [Indexed: 02/08/2023]
Abstract
OBJECTIVE The objective of this study was to investigate and compare the hemodynamic and turbulence characteristics upon implantation of St Jude Medical (SJM) (St Jude Medical, St Paul, Minn) and On-X (On-X Life Technologies, Kennesaw, Ga) bileaflet mechanical valves. Both valves are considered highly successful bileaflet mechanical valves characterized by good clinical outcomes despite their numerous design differences. Although thromboembolism remains the main disadvantage of bileaflet mechanical valves, On-X valves have been shown to need less anticoagulation therapy. METHODS Hemodynamic assessment of a 23-mm On-X bileaflet mechanical valve and a 23-mm bileaflet SJM valve implanted in an aortic root was performed under pulsatile physiologic conditions. Time-resolved and phase-locked particle-image-velocimetry images and high-speed imaging data were acquired. Pressure gradients, effective orifice areas, dimensionless area index, leaflet position tracking, velocity, and principal Reynolds shear stress were calculated. RESULTS Pressure gradient for the On-X valve was 4.15 ± 0.099 mm Hg versus 4.75 ± 0.048 mm Hg for SJM (P < .001). Effective orifice area for the On-X valve was 2.61 ± 0.045 cm2 versus 2.36 ± 0.022 cm2 for SJM (P < .001). Area index was higher with SJM (0.87 ± 0.008) than with On-X (0.73 ± 0.013) (P < .001). On-X showed fluctuating leaflet behavior during systole, whereas SJM leaflets were stable. At peak systole, the maximal velocity with On-X was 1.86 m/s versus 2.33 m/s with SJM. Reynolds shear stress was higher with On-X compared with SJM at peak systole (95 vs 72 Pa). Higher velocity fluctuation was noted with the On-X valve. CONCLUSIONS This study shows that despite the design differences that characterize the On-X valve, the hemodynamic and turbulence parameters were not necessarily improved compared with SJM.
Collapse
Affiliation(s)
- Hoda Hatoum
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio
| | - Pablo Maureira
- Department of Cardiovascular Surgery, CHU de Nancy, Nancy, France
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio.
| |
Collapse
|
2
|
Mannam G, Mishra Y, Modi R, Gokhale AGK, Sethuratnam R, Pandey K, Malhotra R, Anand S, Borah A, Mukhopadhyay S, Shah D, Mahant TS. Early hemodynamic performance of the Trifecta™ surgical bioprosthesis aortic valve in Indian patient population: 12 month outcomes of the EVEREST post-market study. J Cardiothorac Surg 2018; 13:96. [PMID: 30253784 PMCID: PMC6157043 DOI: 10.1186/s13019-018-0783-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Accepted: 08/29/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Indian patients undergoing surgical aortic valve replacement (SAVR) differ from western populations with respect to aortic annulus size and valve disease morphology. The purpose of this post-market, non-randomized observational study was to evaluate the early hemodynamic performance of the Trifecta™ bioprosthesis (Abbott, previously St. Jude Medical, Minneapolis, US) in an Indian patient population. METHODS From January 2014 to September 2015, 100 patients (mean age 64.4 ± 7.1 years, 62% male) undergoing SAVR for valve disease (68% stenosis, 7% insufficiency, 25% mixed pathology) were enrolled across 10 centers in India. Patients implanted with a 19-27 mm Trifecta™ valve were eligible to participate and were prospectively followed for 12-months post-implantation. Echocardiographic hemodynamic performance was evaluated at pre-implant, pre-discharge and at 12-months by an independent core laboratory. Adverse events were adjudicated by the study sponsor. Functional status at 12-months was assessed according to NYHA classification. Continuous data was summarized using descriptive statistics (mean &standard deviation,) and categorical data was summarized using frequencies and percentages. RESULT Ninety patients (mean age 64.5, 62.2% male) completed the 12-month follow up. Significant improvements in hemodynamic valve performance were reported in 81 patients with available echocardiographic data at 12 months. Compared to baseline at 12-month follow up visit, mean effective orifice area increased from 0.75cm2 to 1.61cm2 (p < 0.0001), mean pressure gradient reduced to 10.42 mmHg from 51.47 mmHg (p < 0.0001), cardiac output increased from 4.46 l/min to 4.85 l/min (P 0.9254). Compared to baseline, functional status improved by ≥1 NYHA class in 75% of patients at 12 months (95% Clopper-Pearson (Exact) confidence limit [64.6%, 83.6%]). No instances of early mortality (< 30 days from index procedure) or structural valve dysfunction were reported. CONCLUSION In an Indian patient population, implantation of the Trifecta™ bioprosthesis is shown to be safe and associated with favorable early hemodynamic performance and improved functional status at 12 months. TRIAL REGISTRATION The clinical study has been registered under Clinical Trial Registry-India ( http://www.ctri.nic.in ) and registration number is CTRI/2014/02/004434 registered on 25 February 2014 retrospectively registered.
Collapse
Affiliation(s)
- Gopichand Mannam
- Department of cardiac surgery, Star Hospital Banjara Hills, 8-2-596/5, Road No.10, Banjara Hills, Hyderabad, Telangana, 500034, India.
| | - Yugal Mishra
- Department of cardiac surgery, Escorts Heart Institute and Research Centre, New Delhi, India
| | - Rajan Modi
- Department of cardiac surgery, SAL Hospital, Ahmedabad, India
| | | | - Rajan Sethuratnam
- Department of cardiac surgery, The Madras Medical Mission, Chennai, India
| | - Kaushal Pandey
- Department of cardiac surgery, P. D. Hinduja National Hospital & Medical Research Center, Mumbai, India
| | - Rajneesh Malhotra
- Department of cardiac surgery, Max Super Speciality Hospital, New Delhi, India
| | | | | | | | - Dhiren Shah
- Department of cardiac surgery, Care Institute of Medical Sciences, Ahmedabad, India
| | | |
Collapse
|
3
|
Early and Mid-term Outcome of the St. Jude Medical Regent 19-mm Aortic Valve Mechanical Prosthesis. Functional and Haemodynamic Evaluation. Heart Lung Circ 2017; 27:235-247. [PMID: 28400190 DOI: 10.1016/j.hlc.2017.02.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 01/23/2017] [Accepted: 02/14/2017] [Indexed: 11/21/2022]
Abstract
BACKGROUND AND OBJECTIVES The aim of the present study is to report the early and mid-term clinical and haemodynamic results of the St Jude Medical Regent 19-mm aortic mechanical prothesis (SJMR-19). MATERIALS AND METHODS Between January 2002 and January 2012, 265 patients with aortic valve disease underwent AVR (Aortic Valve Replacement) with a SJMR-19 (St Jude Medical Regent Nr.19). There were 51 males. Mean age was 67.5±12.72years and mean body surface area (BSA) was 1.67±0.14m2. Thirty-six patients required annulus enlargement. The mean follow-up was 34.5±18.8months (range 6-60 months). All patients underwent echocardiographic examination at discharge and within 1 year after surgery. RESULTS There were 14 (5.3%) hospital deaths. Six of the hospital deaths were identified in patients undergoing reoperation, significantly higher than patients undergoing first time operation (p=0.0001). Also the postoperative mortality was significantly higher in patients undergoing annulus enlargement versus patients not requiring annulus enlargement (p=0.02). The mean transprosthesis gradient at discharge was 19±9mmHg. At 6 months follow-up the mean NYHA FC class was 1.6±0.5 significantly lower than preoperatively 2.4±0.75 (p <0.0001). The M-TPG was 15.2±6.5mmHg within 1 year after surgery. Left ventricular mass (LVM) and indexed left ventricular mass (LVMi) were significantly lower than preoperatively The actuarial survival and cumulative freedom from reoperation at 1, 2 and 3 years follow-up were 99.5%, 97.5%, 96.7% and 99.2%, 96.5%, 94.5% respectively. The cumulative actuarial free-events survival at 4 years was 92%. The Cox model identified age (p=0.015), LVEF≤35% (p=0.043), reoperation (p=0.031), combined surgery (p=0.00002), and annulus enlargement (p=0.015) as strong predictors for poor actuarial free-major events survival. CONCLUSIONS The SJMR-19 offers excellent postoperative clinical, haemodynamic outcome and LVMi reduction in patients with small aortic annulus. These data demonstrate that the modern St Jude small mechanical protheses do not influence the intermediate free-reoperation survival.
Collapse
|
4
|
Bertrand PB, Pettinari M, De Cannière H, Gutermann H, Smeets CJ, Verhaert D, Dion RA, Verdonck P, Vandervoort PM. Effective Orifice Area during Exercise in Bileaflet Mechanical Valve Prostheses. J Am Soc Echocardiogr 2017; 30:404-413. [DOI: 10.1016/j.echo.2016.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Indexed: 10/20/2022]
|
5
|
Offstad J, Andersen K, Paulsson P, Andreasson J, Kjellman U, Lundblad O, Engstrøm KG, Haaverstad R, Svennevig JL. The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve. J Cardiothorac Surg 2011; 6:163. [PMID: 22182835 PMCID: PMC3265416 DOI: 10.1186/1749-8090-6-163] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2011] [Accepted: 12/19/2011] [Indexed: 11/25/2022] Open
Abstract
Background 112 patients who received small and medium sized St.Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. Material and methods 46 woman and 66 men, aged 61.8 ± 9.7 (18-75) years, were operated on for aortic regurgitation (17), stenosis (65), or mixed dysfunction (30). Valve sizes were 19 mm (6), 21 mm (33), 23 mm (41), 25 mm (30). Two patients receiving size 27 valves were excluded from the hemodynamic evaluation. Pledgets were used in 100 patients, everted mattress in 66 and simple interrupted sutures in 21. Valve orientation varied and was dependent on the surgeons' choice. 34 patients (30.4%) underwent concomitant coronary artery surgery. Results There were two early deaths (1.8%) and three late deaths, one because of pancreatic cancer. Late events during follow-up were: non structural dysfunction (1), bleeding (2), thromboembolism (2). At one year follow up 93% of the patients were in NYHA classes 1-2 versus 47.8% preoperatively. Dobutamine stress echocardiography (DSE) was performed in a total of 66 and maximal peak stress was reached in 61 patients. During DSE testing, the following statistically significant changes took place: Heart rate increased by 73.0%, cardiac output by 85.5%, left ventriclular ejection fraction by 19.6%, and maximal mean prosthetic transvalvular gradient by 133.8%, whereas the effective orifice area index did not change. Left ventricular mass fell during one year from 215 ± 63 to 197 ± 62 g (p < 0.05). Conclusion The Dobutamine test induces a substantial stress, well suitable for echocardiographic assessment of prosthesis valve function and can be performed in the majority of the patients. The changes in pressure gradients add to the hemodynamic characteristics of the various valve sizes. In our patients the St. Jude Regent valve performed satisfactory at rest and under pharmacological stress situation.
Collapse
Affiliation(s)
- Jon Offstad
- Oslo University Hospital, Rikshospitalet, PO box 4950, Nydalen, NO 0424 Oslo, Norway
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Guenzinger R, Eichinger WB, Hettich I, Bleiziffer S, Ruzicka D, Bauernschmitt R, Lange R. A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: Is there an additional benefit of supra-annular valve positioning? J Thorac Cardiovasc Surg 2008; 136:462-71. [PMID: 18692658 DOI: 10.1016/j.jtcvs.2007.12.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2007] [Revised: 12/06/2007] [Accepted: 12/18/2007] [Indexed: 11/27/2022]
|
7
|
Minardi G, Manzara C, Creazzo V, Maselli D, Casali G, Pulignano G, Musumeci F. Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography. J Cardiothorac Surg 2006; 1:27. [PMID: 16984626 PMCID: PMC1586008 DOI: 10.1186/1749-8090-1-27] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2006] [Accepted: 09/19/2006] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 +/- 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 microg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 +/- 7.1 and 16.6 +/- 5.8 mmHg, respectively; EOA and EOAi resulted 1.14 +/- 0.3 cm(2) and 0.76 +/- 0.2 cm(2)/m(2); DVI was normal (0.50 +/- 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 +/- 43 g and 157.4 +/- 27.7 g/m(2) to 191 +/- 23.8 g and 114.5 +/- 10.6 g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 +/- 2 1.9 mmHg), MnPG (up to 43.2 +/- 12.7 mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 +/- 0.4 cm(2), 0.75 +/- 0.3 cm(2)/m(2) and 0.48 +/- 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression.
Collapse
Affiliation(s)
- Giovanni Minardi
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| | - Carla Manzara
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| | - Vittorio Creazzo
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| | - Daniele Maselli
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| | - Giovanni Casali
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| | - Giovanni Pulignano
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| | - Francesco Musumeci
- Department of Cardiology and Cardiovascular Surgery, Azienda Ospedaliera, S.Camillo-Forlanini, Rome, Italy
| |
Collapse
|
8
|
Zeng YJ, Xu SW, Wang Q, Chang Y, Dong AQ, Chen RK, Yu XJ. Assessment of hemodynamics properties of a new-type artificial heart valve prosthesis using catheterization and echocardiography. Am J Hematol 2006; 81:563-7. [PMID: 16823819 DOI: 10.1002/ajh.20686] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The objectives of this study were to assess the hemodynamic properties of the newly developed artificial heart valve prosthesis experimentally in laboratory simulation, in an animal model, and clinically in a human model and to compare the results measured by catheterization and echocardiography. METHODS (1) Laboratory simulation. The prosthesis was tested using a pulsatile flow simulator in the aortic position. Hydrodynamics parameters were automatically analyzed through a custom-designed data processing program. (2) Animal experiment. Six sheep subjected to mitral replacement with 21-mm-valve prosthesis were measured by open cardiac catheterization intraoperatively. Doppler echocardiography and open cardiac catheterization under dobutamine stress were performed in two sheep subjected to implantation 2.5 years ago. (3) Clinical patient observation. Observations were carried out on 14 patients with aortas replacement and 10 patients with bicuspid replacement using both doppler echocardiography and open cardiac catheterization. RESULTS (1) Laboratory simulation. The results showed that the value of the transvalvular gradient (DeltaP) decreased with the increase of heart rate, and the values were not greater that 10 mm Hg at any given tissue annulus diameter. (2) Animal experiment. The mean DeltaP value of the six sheep was 5.2 +/- 1.7 mm Hg intraoperatively, while the corresponding DeltaP value of the two sheep 2.5 years after implantation was 6.1 +/- 0.3 mm Hg measured by open cardiac catheterization. (3) Clinical patient observation. The mean DeltaP values in the aortic position measured by catheterization and echocardiography were 6.26 approximately 4.10 and 9.42 approximately 7.48 mm Hg, respectively. The gradients in the mitral position were 2.10 approximately 1.9 and 5.28 approximately 4.10 mm Hg, respectively. CONCLUSIONS The results demonstrate that the new-type bileaflet heart valve prosthesis only generates a relatively low transvalvar gradient and thus has good hemodynamic properties.
Collapse
Affiliation(s)
- Y J Zeng
- Shantou Medical College, Shantou University, Shantou 515031, China.
| | | | | | | | | | | | | |
Collapse
|
9
|
Guenzinger R, Eichinger WB, Botzenhardt F, Bleiziffer S, Wagner I, Bauernschmitt R, Wildhirt SM, Lange R. Rest and Exercise Performance of the Medtronic Advantage Bileaflet Valve in the Aortic Position. Ann Thorac Surg 2005; 80:1319-26. [PMID: 16181862 DOI: 10.1016/j.athoracsur.2005.02.094] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2004] [Revised: 01/25/2005] [Accepted: 02/01/2005] [Indexed: 11/29/2022]
Abstract
BACKGROUND The aim of the study was to evaluate rest and exercise performance and left ventricular mass regression of the Medtronic Advantage (Medtronic, Inc, Minneapolis, MN) prosthesis in the aortic position at 1 year at a single center as part of a multicenter, prospective clinical trial. METHODS Between May 2002 and June 2003, 63 consecutive patients underwent aortic valve replacement with a Medtronic Advantage prosthesis (84.1% male; mean age, 56.0 +/- 9.7 years; ejection fraction, 56.5 +/- 15.8%). Valve lesions were stenosis (n = 20), mixed (n = 34), and insufficiency (n = 9). Concomitant procedures were performed in 34.9%. Follow-up was 100% complete. Echocardiographic data were obtained early postoperatively and at 1 year, combined with stress echocardiography by treadmill. Mean pressure gradients, stroke volume, and left ventricular mass were determined by echocardiography. Data are presented as mean +/- standard deviation. RESULTS Operative mortality was 0%. Valve-related complications were observed in 2 patients (endocarditis, n = 1; thromboembolic event, n = 1). There was no case of antithromboembolic hemorrhage, prosthesis-related explant, or reoperation. One patient showed moderate paravalvular regurgitation. Mean pressure gradients 1 year postoperatively ranged from 6.3 to 11.0 mm Hg across all valve sizes. Left ventricular mass regression at 1 year was 18.4% across all valve sizes (p < 0.001). No severe patient-prosthesis mismatch (effective orifice area index < or = 0.65 cm2/m2) could be observed. CONCLUSIONS After 1 year, the Medtronic Advantage valve shows comparable transvalvular mean pressure gradients across the valve sizes used during rest and exercise. This is accompanied by a significant left ventricular mass regression, an important indicator for long-term survival.
Collapse
Affiliation(s)
- Ralf Guenzinger
- Department of Cardiothoracic Surgery, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Abstract
Stress echocardiography is a safe and valuable test to aid in the diagnosis and management of patients with aortic valve disorders. In patients with suspected severe aortic stenosis (AS) and low aortic gradients secondary to low cardiac output, dobutamine echocardiography distinguishes those patients with contractile reserve (CR) from those without it. By increasing the stroke volume in subjects with CR, true severe AS patients have an increase in transaortic gradients without a significant change in the valve area, whereas patients with pseudostenosis have an increase in the gradients with concomitant increase in the aortic valve area to >1 cm(2). Patients without CR are indeterminate in their AS status and have a poor prognosis. The presence of CR is also important in patients suffering from aortic insufficiency, as it may predict the development of symptoms, myocardial dysfunction, or death in the asymptomatic phase of the disease, and the potential for left ventricular functional recovery after valve replacement. Finally, both exercise and dobutamine echocardiography can help in the assessment of valve malfunction or mismatch in patients with aortic valve prostheses experiencing exercise intolerance by correlating the symptoms with the change in the aortic gradients induced during stress testing.
Collapse
Affiliation(s)
- Wen-Chih Wu
- Division of Cardiology, Providence VA Medical Center, and The Miriam Hospital, Brown Medical School, Providence, Rhode Island 02908, USA.
| | | | | |
Collapse
|
11
|
Milano AD, De Carlo M, Mecozzi G, D'Alfonso A, Scioti G, Nardi C, Bortolotti U. Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses: comparison at long-term follow-up. Ann Thorac Surg 2002; 73:37-43. [PMID: 11834061 DOI: 10.1016/s0003-4975(01)03306-9] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Small-sized prostheses for aortic valve replacement may result in residual left ventricular outflow tract obstruction. Aim of the study was to verify whether implantation of 19-mm versus 21-mm St. Jude Medical standard prostheses (St. Jude Medical, Inc, St. Paul, MN) influences long-term clinical outcome. METHODS Two hundred twenty-nine patients who underwent aortic valve replacement with 19 mm (group 1, 53 patients) or 21-mm St. Jude Medical standard prostheses (group 2, 176 patients) were included in the study. Mean follow-up of current survivors was 10+/-4 years. RESULTS Operative mortality was 7.5% in group 1 and 8.5% in group 2. At discharge, an important patient-prosthesis mismatch (effective orifice area index < or = 0.60 cm2/m2) was present in 18% of group 1 versus 5% in group 2 (p = 0.004). Among patients with body surface area less than 1.70 m2, such mismatch was present in 15% of group 1 versus 2% of group 2 (p = 0.008). At last follow-up New York Heart Association (NYHA) functional class (p < 0.001), left ventricular mass reduction (p = 0.02), mean (p = 0.002) and peak transprosthetic gradients (p < 0.001), and effective orifice area index (p = 0.005) were significantly better in group 2. Freedom from sudden death (92%+/-5% vs 99%+/-1%, p = 0.01), valve-related death (84%+/-6% vs 90%+/-5%, p = 0.02), and cardiac events (56%+/-13% vs 86%+/-4%, p = 0.008), were significantly lower in group 1. Effective orifice area index was an independent predictor of late cardiac events. CONCLUSIONS Although long-term results after aortic valve replacement with small-sized St. Jude Medical standard prostheses are satisfactory, 19-mm valve recipients show a high prevalence of important patient-prosthesis mismatch with less evident functional improvement and higher rate of cardiac events, suggesting a very cautious use of this prosthesis.
Collapse
Affiliation(s)
- Aldo D Milano
- Divisions of Cardiac Surgery and Cardiology, Cardio-Thoracic Department University of Pisa Medical School, Italy
| | | | | | | | | | | | | |
Collapse
|
12
|
Silberman S, Shaheen J, Merin O, Fink D, Shapira N, Liviatan-Strauss N, Bitran D. Exercise hemodynamics of aortic prostheses: comparison between stentless bioprostheses and mechanical valves. Ann Thorac Surg 2001; 72:1217-21. [PMID: 11603439 DOI: 10.1016/s0003-4975(01)03064-8] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Nonstented bioprostheses have been associated with lower resting gradients than stented bioprostheses or mechanical valves. We compared the hemodynamic performance of nonstented bioprostheses and mechanical valves with normal native aortic valves at rest and exercise. METHODS Dobutamine echocardiography was used to assess gradients and effective orifice area index at rest and exercise in patients with the Toronto stentless porcine valve (TSPV; n = 13; mean implant size 25.7 mm), Medtronic Freestyle (FR; n = 11; mean implant size 23.9 mm), Sorin Bicarbon (SOR; n = 11; mean implant size 24.5 mm), St. Jude Medical (SJM; n = 10; mean implant size 21.3 mm), and normal native aortic valves (NOR; n = 10). RESULTS All groups demonstrated a major rise in cardiac output at maximal dobutamine infusion. At rest and exercise, respectively, mean gradients were 5.48 +/- 1.1 mm Hg and 5.83 +/- 0.9 mm Hg for TSPV, 5.68 +/- 1.2 mm Hg and 7.50 +/- 1.7 mm Hg for FR, 10.29 +/- 1.4 mm Hg and 20.78 +/- 2.7 mm Hg for SJM, 5.26 +/- 0.8 mm Hg and 11.1 +/- 1.8 mm Hg for SOR, and 1.54 +/- 0.4 mm Hg and 2.18 +/- 0.7 mm Hg for NOR. In comparison with normal valves, both stentless groups showed no change in mean gradient at exercise, whereas both mechanical groups showed an increase in gradient at exercise (p < 0.04). CONCLUSIONS Stentless valves behave similarly to normal aortic valves in that there is almost no increase in gradient at exercise. Both mechanical valve groups showed increased gradients at exercise, suggesting that these valves obstruct blood flow. Our data add further evidence that stentless valves are hemodynamically superior to mechanical valves in the aortic position.
Collapse
Affiliation(s)
- S Silberman
- Department of Cardiac Surgery, Shaare Zedek Medical Center, Jerusalem, Israel.
| | | | | | | | | | | | | |
Collapse
|
13
|
Kadir I, Wan IY, Walsh C, Wilde P, Bryan AJ, Angelini GD. Hemodynamic performance of the 21-mm Sorin Bicarbon mechanical aortic prostheses using dobutamine Doppler echocardiography. Ann Thorac Surg 2001; 72:49-53. [PMID: 11465229 DOI: 10.1016/s0003-4975(01)02666-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Small-sized mechanical aortic prostheses are commonly associated with generation of high transvalvular gradients, particularly in patients with large body surface area, and can result in patient-prosthesis mismatch. This study evaluates the hemodynamic performance of 21-mm Sorin Bicarbon bileaflet mechanical prostheses using dobutamine stress echocardiography. METHODS Fourteen patients (7 women; mean age, 63+/-8 years) who had undergone aortic valve replacement with a 21-mm Sorin Bicarbon bileaflet mechanical prosthesis 32.4+/-5.1 months previously were studied. After a resting Doppler echocardiogram, a dobutamine infusion was started at a rate of 5 microg x kg(-1) x min(-1) and increased to 30 microg x kg(-1) x min(-1) at 15-minute intervals. Pulsed- and continuous-wave Doppler echocardiographic studies were performed at rest and at the end of each increment of dobutamine. Both peak and mean velocity and pressure gradient across the prostheses were measured, and effective orifice area, discharge coefficient, and performance index were calculated. RESULTS Dobutamine stress increased heart rate and cardiac output by 83% and 81%, respectively (both p < 0.0001), and mean transvalvular gradient increased from 15.6+/-5.5 mm Hg at rest to 35.4+/-11.9 mm Hg at maximum stress (p < 0.0001). Although the indexed effective orifice area was significantly lower in patients with a larger body surface area, this was not associated with any significant pressure gradient. The performance index of this valve was unchanged throughout the study. Regression analyses demonstrated that the mean transvalvular gradient at maximum stress was independent of all variables except resting gradient (p = 0.05). Body surface area had no association with the changes in cardiac output, transvalvular gradient at maximum stress, and effective orifice area. CONCLUSIONS These data show that the 21-mm Sorin Bicarbon bileaflet mechanical prosthesis offers an excellent hemodynamic performance with full utilization of its available orifice when implanted in the aortic position. The lack of significant transvalvular gradient in patients with a larger body surface area suggests that patient-prosthesis mismatch is highly unlikely when this prosthesis is used.
Collapse
Affiliation(s)
- I Kadir
- Bristol Heart Institute and Department of Clinical Radiology, University of Bristol, United Kingdom
| | | | | | | | | | | |
Collapse
|
14
|
Mannaerts H, Li Y, Kamp O, Valocik G, Hrudova J, Ripa S, Visser C. Quantitative assessment of mechanical prosthetic valve area by 3-dimensional transesophageal echocardiography. J Am Soc Echocardiogr 2001; 14:723-31. [PMID: 11447419 DOI: 10.1067/mje.2001.112891] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The goal of this study was to assess the geometric orifice area of mechanical valve prostheses by transesophageal 3-dimensional echocardiographic planimetry. METHODS AND RESULTS Currently used Doppler methods for prosthetic assessment (orifice area-Doppler) were compared with 3D planimetry for orifice area (orifice area-3D) and with manufacturer's values (orifice area-manufacturer) for the corresponding prosthesis types and sizes and with historical controls provided by Doppler literature (orifice area-literature). Twenty-four mechanical valve prostheses (in 22 patients) were studied: 13 in mitral position and 11 in aortic position. Orifice area-manufacturer, orifice area-Doppler, orifice area-literature, and orifice area-3D were 3.6 +/- 1.1 cm(2), 2.3 +/- 0.9 cm(2), 2.4 +/- 0.9 cm(2), and 2.6 +/- 0.7 cm(2), respectively. Orifice area-manufacturer values were significantly larger. Correlation coefficients between orifice area-3D and orifice area-manufacturer, and between orifice area-3D and orifice area-Doppler and orifice area-literature were 0.83, 0.90, and 0.73, respectively (all P < .0001). CONCLUSION Three-dimensional transesophageal echocardiography is feasible and has good correlation with orifice area-Doppler (in aortic position) and good correlation with orifice area-manufacturer (in aortic and mitral positions) methods.
Collapse
Affiliation(s)
- H Mannaerts
- Department of Cardiology, University Hospital VU, Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
15
|
Knez I, Rienmüller R, Maier R, Rehak P, Schröttner B, Mächler H, Anelli-Monti M, Rigler B. Left ventricular architecture after valve replacement due to critical aortic stenosis: an approach to dis-/qualify the myth of valve prosthesis-patient mismatch? Eur J Cardiothorac Surg 2001; 19:797-805. [PMID: 11404133 DOI: 10.1016/s1010-7940(01)00683-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/16/2022] Open
Abstract
OBJECTIVES Left ventricular hypertrophy in patients with critical aortic stenosis (AS) is an adaptive process that compensates for high intracavitary pressure and reduces systolic wall stress followed by an increase in myocardial masses. In the present prospective clinical trial, we investigated long-term compensatory changes in left ventricular geometry and function after aortic valve replacement using mechanical bileaflet prostheses with the main emphasis on the small-sized aortic annulus and valve prosthesis-patient mismatch. METHODS A total of 58 patients with critical AS were assigned to the following groups according to the predictive value of prosthetic valve area index (VAI): group EXMIS: 29 patients (VAI < or =0.99), expected mismatch; group NOMIS: 29 patients (VAI < or =0.99), no mismatch. At controls T(0) (before operation/operation (OP), T(1) and T(2) (4 and 20 months after OP) the left ventricular geometry was recorded by means of Imatron electron beam tomography and the transprosthetic velocities were measured by echocardiography. RESULTS Statistical analysis showed a consistent reduction in the absolute (P=0.04) and indexed (P=0.04) left ventricular myocardial mass for both cohorts; furthermore, there was a significant difference between EXMIS and NOMIS patients concerning the factors, time and mass reduction (P=0.005), because of distinct baselines. A logistic regression report revealed preoperative cardiac output, absolute left ventricular myocardial mass, perfusion, body surface area and the native valve orifice area as predicting coefficients and factors for a minimum mass reduction of 25%. We explain a mathematical formula that turned out to be the most sensitive for correctly classified factors. CONCLUSIONS The left ventricular geometry and transprosthetic velocities resulted in the same postoperative recovery for both EXMIS and NOMIS patients. The presented data showed that valve prosthesis-patient mismatch had no influence in several stepwise logistic regression models. We conclude that modern mechanical bileaflet prostheses allow both acceptable hemodynamics and recovery of left ventricular hypertrophy, even in small aortic annuli.
Collapse
Affiliation(s)
- I Knez
- Division of Cardiac Surgery, Karl Franzens University and Medical School of Graz, Graz, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000; 36:1131-41. [PMID: 11028462 DOI: 10.1016/s0735-1097(00)00859-7] [Citation(s) in RCA: 428] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Prosthesis-patient mismatch is present when the effective orifice area of the inserted prosthetic valve is less than that of a normal human valve. This is a frequent problem in patients undergoing aortic valve replacement, and its main hemodynamic consequence is the generation of high transvalvular gradients through normally functioning prosthetic valves. The purposes of this report are to present an update on the concept of aortic prosthesis-patient mismatch and to review the present knowledge with regard to its impact on hemodynamic status, functional capacity, morbidity and mortality. Also, we propose a simple approach for the prevention and clinical management of this phenomenon because it can be largely avoided if certain simple factors are taken into consideration before the operation.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Laval University, Sainte-Foy, Canada
| | | |
Collapse
|
17
|
Maslow AD, Haering JM, Heindel S, Mashikian J, Levine R, Douglas P. An evaluation of prosthetic aortic valves using transesophageal echocardiography: the double-envelope technique. Anesth Analg 2000; 91:509-16. [PMID: 10960367 DOI: 10.1097/00000539-200009000-00002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
UNLABELLED The conventional continuity equation uses nonsimultaneous measurements of blood flow velocities through the left ventricular outflow tract and across the aortic valve to calculate aortic valve area (AVA). We have noted that both velocities can be simultaneously obtained from continuous wave (CW) Doppler analysis (double-envelope [DE]). We hypothesize that prosthetic AVA can be calculated by using the DE technique, during transesophageal echocardiography (TEE). Prosthetic AVA was calculated in 41 of 45 patients immediately after aortic valve replacement by using the DE/AVA technique. Left ventricular outflow tract diameter was obtained from an esophageal view, while subvalvular (V(1)) and valvular (V(2)) peak velocities were simultaneously obtained from transgastric views by using CW Doppler. Prosthetic AVA and V(1)/V(2) ratio (Doppler velocity index) were calculated. V(1) was also measured by using pulse wave Doppler, as is conventionally done. Twenty-three Carbomedic (CM) and 18 Carpentier-Edwards (CE) AVA were evaluated. DE/AVAs for CM and CE valves correlated and agreed with that reported by the manufacturer (CM r(2) = 0.91, mean bias -0.25 cm(2) [SD 0.18]; CE r(2) = 0.73, mean bias -0.02 cm(2) [SD 0.27]). Calculated Doppler velocity index values agree with available data (mean bias 0.03 [SD 0.05]). The V(1) obtained by using the DE method was nearly identical to the V(1) obtained by using pulse wave (r(2) = 0.95, mean bias 0.02 m/s [SD 0.04 m/s]). TEE assessment of prosthetic AVA using the DE technique agrees with data reported by the manufacturer. Obtaining subvalvular and valvular velocities from the same CW Doppler trace may simplify the continuity equation and help avoid errors caused by beat-to-beat changes in blood flow. Quantitative prosthetic aortic valve assessment can be performed, on-line, with TEE by using the DE technique. IMPLICATIONS Quantitative assessment of prosthetic aortic valve area can be performed on-line by using transesophageal echocardiography using the double envelope technique.
Collapse
Affiliation(s)
- A D Maslow
- Departments of Anesthesia and Cardiology, Beth Israel-Deaconess Medical Center. Mass General Hospital, Boston, MA, USA.
| | | | | | | | | | | |
Collapse
|
18
|
Maslow AD, Haering JM, Heindel S, Mashikian J, Levine R, Douglas P. An Evaluation of Prosthetic Aortic Valves Using Transesophageal Echocardiography: The Double-Envelope Technique. Anesth Analg 2000. [DOI: 10.1213/00000539-200009000-00002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
19
|
Izzat MB, Kadir I, Reeves B, Wilde P, Bryan AJ, Angelini GD. Patient-prosthesis mismatch is negligible with modern small-size aortic valve prostheses. Ann Thorac Surg 1999; 68:1657-60. [PMID: 10585038 DOI: 10.1016/s0003-4975(99)00717-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND Concern has been raised about residual significant gradients when small aortic prostheses are used, particularly in patients with large body surface areas. We studied the performance of six types of small aortic prostheses using dobutamine stress echocardiography. METHODS Sixty-three patients (mean age, 67 +/- 7 years) who had undergone aortic valve replacement 17 +/- 6 months previously were studied. Two bileaflet mechanical prostheses (St. Jude Medical and CarboMedics: sizes, 19 mm and 21 mm) and two biological prostheses (Medtronic Intact and St. Jude BioImplant: size, 21 mm) were evaluated. A graded infusion of dobutamine was given and Doppler studies of valve performance were carried out. RESULTS All prostheses except one biological valve had acceptable hemodynamic performance under stress. Using regression modeling, gradient at rest was the only variable found to predict gradient under stress (p < 0.001). Moreover, the most important predictor of gradient at rest was valve design, which accounted for 72% of the variance (p < 0.001). This relationship was independent of valve size (19 mm or 21 mm) or material (ie, mechanical or biological). Body surface area accounted for 4% of the variance in gradient only. CONCLUSIONS The main predictor of transprosthetic gradient is the inherent characteristics of each particular prosthesis, with relatively insignificant contribution from variations in body surface area. Patient-prosthesis mismatch is not a problem of clinical significance when certain modern valve prostheses are used.
Collapse
Affiliation(s)
- M B Izzat
- Bristol Heart Institute and Research and Development Support Unit, University of Bristol, England.
| | | | | | | | | | | |
Collapse
|
20
|
González-Juanatey JR, Fernández MV, Sampedro FG, García-Acuña JM, García-Bengoechea JB, Cendon AA, de La Peña MG. Haemodynamic performance of aortic pericardial bioprostheses and bileaflet prostheses at rest and during exercise: implications for the surgical management of patients with small aortic roots. Heart 1999; 82:149-55. [PMID: 10409527 PMCID: PMC1729145 DOI: 10.1136/hrt.82.2.149] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVE To determine the haemodynamic behaviour, at rest and during exercise, of aortic valve pericardial bioprostheses and different sizes of bileaflet prosthesis. DESIGN Observational study. SETTING Tertiary medical centre. PATIENTS AND INTERVENTIONS 74 patients (33 women, 41 men; mean age 64 years) in whom 40 pericardial bioprostheses and 34 bileaflet prostheses sized 19, 21, or 23 mm had been implanted to replace aortic valves. MAIN OUTCOME MEASURES Doppler echocardiography at rest and at peak exercise, between 12 and 47 months after surgery. RESULTS All patients achieved a significant increase in heart rate, systolic blood pressure, and cardiac output with exercise. Transvalvar pressure fall, valve area, and left ventricular systolic and diastolic function indices also underwent significant changes with exercise. Reductions in peak and mean transvalvar pressure, at rest and at peak exercise, were greater in patients with small valves (p < 0.05). Valve areas and effective area index were greater in the patients with larger valves (p < 0.001). There were no significant differences between patients with mechanical and biological prostheses with regard to transvalvar pressure fall and valve areas at rest and at peak exercise. CONCLUSIONS 19 mm and 21 mm aortic prostheses and bioprostheses continue to create significant obstruction, particularly with exercise.
Collapse
Affiliation(s)
- J R González-Juanatey
- Department of Cardiology, Galician General Hospital and University of Santiago Faculty of Medicine, 15705 Santiago de Compostela, Spain.
| | | | | | | | | | | | | |
Collapse
|
21
|
Abstract
Stress echocardiography has been widely accepted as an important diagnostic and prognostic tool in the assessment of known or suspected coronary artery disease. Its use in valvular heart disease, to date, has been more limited, but is continuing to grow as the technology and the understanding of valvular disorders progress. In this article, we will review the current literature regarding the use of both exercise and pharmacological stress testing in conjunction with echocardiography in the settings of native and prosthetic mitral and aortic valve disease. We will also discuss the limitations of this modality and touch upon possible future areas of investigation.
Collapse
Affiliation(s)
- B F Decena
- Cardiology Unit, University of Vermont School of Medicine, Burlington, USA
| | | |
Collapse
|
22
|
Eriksson MJ, Rosfors S, Brodin LA. Temporal variability of exercise Doppler echocardiography in patients with nonstented aortic bioprostheses. J Am Soc Echocardiogr 1999; 12:484-91. [PMID: 10359920 DOI: 10.1016/s0894-7317(99)70085-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Temporal variability and reproducibility of Doppler-derived variables obtained during supine symptom-limited exercise was investigated in 26 patients who were in clinically and hemodynamically stable condition with normally functioning nonstented aortic bioprostheses (stentless porcine, n = 13; cryopreserved homografts, n = 13). All patients had normal systolic left ventricular function and underwent 2 similar exercise tests within 12 months (mean time interval 7.2 +/- 1.9 months). The coefficient of variation was 8% to 9% for primary Doppler-derived variables (ie, velocities and velocity time integrals) at rest and during exercise. The coefficient of variation for calculated maximal pressure difference was 16% at rest and 15% at peak exercise. Measurement variability assessed from repeated measurements from the same videotaped recording was approximately 2%. High reproducibility was shown for most variables with intraclass correlation coefficients of 0.85 or more. We conclude that Doppler echocardiography can be used in patients with nonstented aortic bioprostheses with the same high reproducibility during exercise as at rest. The results provide clinically useful information regarding temporal variability for Doppler-derived variables.
Collapse
Affiliation(s)
- M J Eriksson
- Department of Clinical Physiology at Karolinska Hospital, South Hospital, Stockholm, Sweden.
| | | | | |
Collapse
|
23
|
Eriksson MJ, Rosfors S, Rådegran K, Brodin LA. Effects of exercise on Doppler-derived pressure difference, valve resistance, and effective orifice area in different aortic valve prostheses of similar size. Am J Cardiol 1999; 83:619-22, A10. [PMID: 10073878 DOI: 10.1016/s0002-9149(98)00930-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The effects of increased transvalvular volume flow on Doppler-derived measurements were compared in similarly sized, normally functioning, mechanical prostheses, stented and stentless porcine bioprostheses, and homografts. Homograft and stentless valves showed the largest effective orifice area and the lowest pressure differences and valve resistance at rest and during exercise-induced increase in flow rates.
Collapse
Affiliation(s)
- M J Eriksson
- Department of Clinical Physiology, Karolinska Hospital and Karolinska Institute, Stockholm, Sweden.
| | | | | | | |
Collapse
|
24
|
Shimabukuro T, Takeuchi Y, Gomi A, Nakatani H, Suda Y, Kono K, Nagano N. [Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve]. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 1998; 46:1285-91. [PMID: 10037837 DOI: 10.1007/bf03217917] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
As the elderly population in Japan increases, senile degenerative aortic valvular disease also tends to increase. These patients often have a small aortic annulus. The problem of "valve-patient-mismatch" occurs when a small prosthesis is inserted into a patient with a small aortic annulus. To avoid annular enlargement after aortic valve replacement (AVR), we tried to use a small-sized St. Jude Medical (SJM) valve. From September 1988 through November 1996, 110 AVR were performed in our institution. In these cases, 30 underwent AVR with a small sized SJM valve (male < or = 21 mm, female < or = 19 mm). Dobutamine stress echocardiography was performed in 19 patients who had undergone AVR with a small-sized SJM valve. Surgical results were also compared between patients with small aortic annulus and those with normal-sized aortic annulus. Using Doppler echocardiography, pressure gradients (PG), cardiac index (CI), effective orifice area (EOA), and performance index (PI) were calculated at rest and during stress. The mean body surface area (BSA) of patient who had undergone AVR with SJM19A, 19HP and 21A was 1.40, 1.42 and 1.56 m2, respectively. With dobutamine stress, heart rates, PG and CI increased significantly. Mean and maximum PG of patients with 19HP (8.0 and 15.4 mmHg at rest, 12.9 and 28.0 mmHg under stress, respectively) and 21A (9.5 and 19.1 mmHg at rest, 16.5 and 35.3 mmHg under stress, respectively) were relatively low. EOA index (EOAI) of patient with 19HP showed the highest values mean 0.93 cm2/m2. PIs tended to be higher with HP models than with standard models. The tests were completed without significant side effects such as frequent ventricular arrhythmias. Among the cases with small aortic annulus, there were no operative deaths or hospital deaths. There were also no late deaths, episodes of hemorrhage or thrombosis. Conclusions. In our institution, AVR was performed safely without any aortic annular enlargement with a small aortic anulus in small BSA patients. Postoperative hemodynamic data obtained by echocardiography were satisfactory for all patients at rest and even during maximum dobutamine stress test.
Collapse
Affiliation(s)
- T Shimabukuro
- Department of Cardiovascular Surgery, Kanto Teishin Hospital, Tokyo, Japan
| | | | | | | | | | | | | |
Collapse
|
25
|
Silberman S, Shaheen J, Fink D, Tzivoni D, Rosenmann D, Shapira N, Strauss-Liviatan N, Bitran D. Comparison of exercise hemodynamics among nonstented aortic bioprostheses, mechanical valves, and normal native aortic valves. J Card Surg 1998; 13:412-6. [PMID: 10440658 DOI: 10.1111/j.1540-8191.1998.tb01105.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND While aortic valve prostheses are known to perform well at rest, few studies have examined them under stress. We compared stress hemodynamics of mechanical valves and nonstented porcine valves in the aortic position to that of normal native aortic valves. METHODS Dobutamine echocardiography was used to assess mean and peak gradients and effective orifice area index (EOAI) at rest and exercise in patients with the Toronto Stentless Porcine Valve (SPV) (n = 13, mean implant size 25.7 mm), Sorin Bicarbon mechanical valve (SOR) (n = 11, mean implant size 24.5 mm), and patients with normal native aortic valves (NOR) (n = 10). Dobutamine infusion was started at 5 micron/kg per minute, and increased by increments of 5 micron/kg per minute until the target heart rate was achieved or until a maximal dose of 40 micron/kg per minute. RESULTS At rest and exercise, respectively, cardiac output (L/min) was 5.2 and 10.4 for Toronto SPV; 7.4 and 13.5 for SOR; and 4.6 and 11.2 for NOR. Measured EOAI (cm2) was 1.1+/-0.2 and 1.15+/-0.2 for TORONTO SPV; 1.60+/-0.3 and 1.58+/-0.3 for SOR; and 1.45+/-0.2 and 1.46+/-0.2 for NOR. Mean gradients (mmHg) were 5.48+/-1.1 and 5.83+/-0.9 for TORONTO SPV; 5.26+/-0.8 and 11.3+/-1.8 for SOR; and 1.54+/-0.4 and 2.18+/-0.7 for NOR. Peak gradients (mmHg) were 11.9+/-2.0 and 21.0+/-3.7 for TORONTO SPV; 10.79+/-1.7 and 25.9+/-3.4 for SOR; and 2.38+/-0.9 and 6.1+/-2.3 for NOR. CONCLUSIONS Although the mechanical group (SOR) had larger measured EOAI, the greater increase in gradients with exercise in this group suggests that the TORONTO SPV is less obstructive to flow.
Collapse
Affiliation(s)
- S Silberman
- Department of Cardiac Surgery, Shaare Zedek Medical Center, Jerusalem, Israel
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Çam N, Gerçekoğlu H, Çelik S, Gürsürer M, Tayyareci G, Karabulut H, Narin A, Tezel T, Yiğiter B. Dobutamine Stress Test to Evaluate Different Sizes of Prosthetic Aortic Valves. Asian Cardiovasc Thorac Ann 1998. [DOI: 10.1177/021849239800600305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Dobutamine stress testing and Doppler echocardiography were used to assess hemodynamics in 27 patients aged 16 to 54 years with various sizes and types of aortic valve prosthesis. All patients underwent a symptom-limited treadmill exercise test within two days of the dobutamine test. There was no significant difference in ejection fractions and transvalvular gradients at rest and during dobutamine stress between St. Jude Medical, Medtronic-Hall, and Carbomedics valves. Exercise duration did not differ significantly among the different types of valve. When patients were classified by their underlying lesion, those with aortic stenosis and those with aortic insufficiency had similar ejection fractions and transvalvular gradients at rest and during dobutamine stress. The mean and peak transvalvular gradients at rest and during dobutamine stress were significantly different in patients with different valve sizes but the extent of the increase in gradients during stress was not significant. Linear regression analysis revealed that both peak and mean gradients during dobutamine stress could be predicted by the resting gradients. There was a negative correlation between valve size and gradients at rest and during stress, while there was a significant correlation between exercise duration and valve size. Dobutamine stress echocardiography was useful for studying hemodynamics in patients with aortic valve prostheses and the findings show that valvular size was the main determinant of exercise capacity.
Collapse
Affiliation(s)
| | - Hakan Gerçekoğlu
- Department of Cardiovascular Surgery Siyami Ersek Thoracic and Cardiovascular Surgery Center İstanbul, Turkey
| | | | | | | | - Hasan Karabulut
- Department of Cardiovascular Surgery Siyami Ersek Thoracic and Cardiovascular Surgery Center İstanbul, Turkey
| | | | | | - Besim Yiğiter
- Department of Cardiovascular Surgery Siyami Ersek Thoracic and Cardiovascular Surgery Center İstanbul, Turkey
| |
Collapse
|
27
|
da Costa F, Haggi H, Pinton R, Lenke W, Adam E, Costa IS. Rest and exercise hemodynamics after the Ross procedure: an echocardiographic study. J Card Surg 1998; 13:177-85. [PMID: 10193987 DOI: 10.1111/j.1540-8191.1998.tb01258.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Aortic prosthetic valves with superior hemodynamic performance are associated with more complete regression of left ventricular hypertrophy and better left ventricular function postoperatively. The near normal function of the pulmonary autografts at rest is well documented, however, exercise data has been seldom reported. The purpose of this study is to evaluate the hemodynamic performance of pulmonary autografts in the aortic position and the homografts used to reconstruct the right ventricular outflow tract during conditions of high cardiac output by means of dobutamine stress echocardiography. METHODS Between May 1995 and February 1998, 67 patients were submitted to a Ross operation at our institution. Twenty of these patients had a mean age of 28.6+/-8.3 years and a mean follow-up time of 15.7+/-5.9 months. They were studied by dobutamine stress echocardiography to evaluate rest and exercise hemodynamics of the pulmonary autografts as well as of the aortic and pulmonary homografts used to reconstruct the right ventricular outflow tract. Dobutamine infusion was started at 5 microg/kg with incremental doses up to 40 microg/kg in every case. RESULTS With dobutamine infusion, heart rate increased from 71+/-10 to 142+/-11 beats/min, left ventricular systolic volume from 86.8+/-33.9 mL to 115.9+/-52.6 mL, and cardiac output from 6.3+/-2.9 L/min to 16.8+/-7.4 L/min. Left ventricular function was considered satisfactory at rest and during exercise in all patients. The mean gradient across the autograft increased from 1.03+/-0.95 mmHg to 4.03+/-2.05 mmHg and maximal instantaneous gradient from 2.45+/-2.21 mmHg to 9.54+/-4.85 mmHg. The mean effective orifice area for the autografts were 3.5+/-1.3 cm2 at rest and 3.3+/-1.4 cm2 during exercise. The patients with mild aortic insufficiency at rest had no increase in the degree of regurgitation with exercise. In the right ventricular outflow tract, the mean gradient across the homograft increased from 9.06+/-5.29 mmHg to 17.55+/-9.76 mmHg and maximal instantaneous gradient from 21.4+/-12.5 mmHg to 41.5+/-23.1 mmHg. CONCLUSIONS Pulmonary autografts exhibit normal hemodynamic performance at rest and during exercise after the Ross operation. However, mild-to-moderate gradients are common at the right ventricular outflow tract and should be carefully monitored.
Collapse
Affiliation(s)
- F da Costa
- Pontifícia Universidade Católica do Paraná and Santa Casa de Curitiba, Brazil
| | | | | | | | | | | |
Collapse
|
28
|
Kadir I, Izzat MB, Birdi I, Wilde P, Reeves B, Walsh C, Bryan A, Angelini G. Hemodynamic performance of the 21-mm St. Jude BioImplant prosthesis using dobutamine Doppler echocardiography. Am J Cardiol 1998; 81:599-603. [PMID: 9514457 DOI: 10.1016/s0002-9149(97)00968-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This study examines the hemodynamic performance of small size St. Jude BioImplant aortic prostheses using dobutamine echocardiography. Eleven patients (3 women, mean age 75 years) who had undergone aortic valve replacement with a size 21-mm St. Jude BioImplant aortic prostheses at 10.8 +/- 5.1 months (SD) previously were studied. Dobutamine infusion was started at a rate of 5 microg/kg/min and increased to 10 microg/kg/min, and subsequently to 20 microg/kg/min at 15-minute intervals. Pulsed and continuous-wave Doppler studies were performed at rest and at the end of each stage. Effective orifice area, mean gradient, and the performance index across each prosthesis were calculated and cardiac output was determined by Doppler measurement of flow in the left ventricular outflow tract. Stress dobutamine increased heart rate and cardiac output by 51% and 56%, respectively (both p <0.0001), and the mean transvalvular gradient increased from 30.1 +/- 7.5 mm Hg at rest to 49.3 +/- 11.5 mm Hg at maximum stress (p <0.0005). The performance index increased progressively from 0.29 +/- 0.05 at rest to 0.40 +/- 0.10 at maximum stress (p <0.0005). Regression modeling analyses demonstrated that the maximum stress gradient was independent of all variables except the resting gradient (p = 0.03). Body surface area had no effect on the changes in cardiac output, effective orifice area, or transprosthetic gradient at maximum stress. Thus, these data demonstrate that the size 21-mm St. Jude BioImplant prosthesis exhibits suboptimal hemodynamic performance with transvalvular gradients consistent with mild to moderate aortic stenosis, both at rest and under stress conditions.
Collapse
Affiliation(s)
- I Kadir
- Bristol Heart Institute, Department of Clinical Radiology, University of Bristol, United Kingdom
| | | | | | | | | | | | | | | |
Collapse
|
29
|
|
30
|
Zabalgoitia M, Kopec K, Abochamh DA, Oneschuk L, Herrera CJ, O'Rourke RA. Usefulness of dobutamine echocardiography in the hemodynamic assessment of mechanical prostheses in the aortic valve position. Am J Cardiol 1997; 80:523-6. [PMID: 9285673 DOI: 10.1016/s0002-9149(97)00410-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Dobutamine stress echocardiography is a simple, safe, and readily available method to evaluate prosthetic valve hemodynamics under various flow conditions. A normal response of aortic valve prostheses to dobutamine infusion is a 100% increment in transprosthetic pressure gradients with an unchanged valve area.
Collapse
Affiliation(s)
- M Zabalgoitia
- Department of Medicine/Cardiology, The University of Texas Health Science Center at San Antonio, 78284-7872, USA
| | | | | | | | | | | |
Collapse
|
31
|
Izzat MB, Yim AP. Assessment of the hemodynamic performance of small-size aortic valve prostheses. J Thorac Cardiovasc Surg 1997; 113:1121-3. [PMID: 9202699 DOI: 10.1016/s0022-5223(97)70307-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
32
|
Tsai CH, Lee TM, Wang CH, Hsu KL, Liau CS, Lee YT, Chu SH. Effects of dobutamine on aortic valve indexes in asymptomatic patients with bileaflet mechanical prostheses in the aortic valve position. Am J Cardiol 1997; 79:1546-9. [PMID: 9185654 DOI: 10.1016/s0002-9149(97)00192-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We investigated the effects of alternating transvalvular flow rate on Doppler-derived aortic valve resistance and valve area in asymptomatic patients with mechanical aortic valve replacement under dobutamine infusion. The Gorlin-derived aortic valve area and continuity equation-derived aortic valve area seem to be less flow dependent; valve resistance tends to be flow dependent.
Collapse
Affiliation(s)
- C H Tsai
- Center for Cardiovascular Research, College of Medicine, National Taiwan University, Taipei
| | | | | | | | | | | | | |
Collapse
|
33
|
Gonzàlez-Juanatey JR. Reply:. J Thorac Cardiovasc Surg 1997. [DOI: 10.1016/s0022-5223(97)70308-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
34
|
De Paulis R, Sommariva L, De Matteis GM, Caprara E, Tomai F, Penta de Peppo A, Polisca P, Bassano C, Chiariello L. Extent and pattern of regression of left ventricular hypertrophy in patients with small size CarboMedics aortic valves. J Thorac Cardiovasc Surg 1997; 113:901-9. [PMID: 9159624 DOI: 10.1016/s0022-5223(97)70263-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE To assess the extent and pattern of regression of left ventricular hypertrophy after valve replacement for aortic stenosis, we studied 26 patients receiving either 19 or 21 mm CarboMedics valves (group I, 13 patients) or either 23 or 25 mm CarboMedics valves (group II, 13 patients). The studies were done before the operation and after 3 years, and results were compared with those of 10 control patients. METHODS Left ventricular end-diastolic and end-systolic diameters and volumes, ejection fraction and fractional shortening, and interventricular septum and posterior wall thickness were measured. The ratio between interventricular septum and posterior wall thickness, the ratio between left ventricular wall thickness and left ventricular chamber radius, and the left ventricular mass were then calculated. RESULTS At follow-up there was a significant reduction in the left ventricular mass, interventricular septum, and posterior wall thickness for both patient groups (p < 0.01). However, only the posterior wall thickness reached normal values; the interventricular septum and the left ventricular mass indices were still significantly greater than in the control group (p < 0.01). Because of the incomplete regression of interventricular septal hypertrophy, the ratio between interventricular septum and posterior wall thickness was similar between both patient groups but it was significantly higher than in control subjects (p < 0.01). The ratio between wall thickness and chamber radius did not decrease significantly in group II patients, in whom it remained above the control values. CONCLUSION Having a bileaflet aortic prosthesis of one size larger did not seem to significantly influence the pattern and the extent of regression of left ventricular hypertrophy after an intermediate period of follow-up.
Collapse
Affiliation(s)
- R De Paulis
- Cardiac Surgery Department, Tor Vergata University of Rome, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Kadir I, Izzat MB, Wilde P, Reeves B, Bryan AJ, Angelini GD. Dynamic evaluation of the 21-mm Medtronic Intact aortic bioprosthesis by dobutamine echocardiography. Ann Thorac Surg 1997; 63:1128-32. [PMID: 9124918 DOI: 10.1016/s0003-4975(97)00190-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND High residual transvalvular gradients have been reported with the use of small Medtronic Intact aortic valve prostheses. The aim of this study was to evaluate the hemodynamic performance of 21-mm prostheses using dobutamine Doppler echocardiography. METHODS Ten patients (7 women; mean age, 79 years) who had undergone aortic valve replacement with 21-mm Medtronic Intact prostheses 19.1 +/- 9.9 (standard deviation) months previously were studied. Dobutamine infusion was started at a rate of 5 microg x kg(-1) x min(-1) and increased to 10 and 20 microg x kg(-1) x min(-1) at 15-minute intervals. Pulsed and continuous-wave Doppler studies were performed at rest and at the end of each stage. Effective orifice area, performance index, and discharge coefficient of each valve were calculated, and peak and mean velocity and pressure drop across the prostheses were measured. Cardiac output was determined by Doppler measurement of flow in the left ventricular outflow tract. RESULTS Dobutamine stress increased heart rate and cardiac output by 68% and 65%, respectively (both p < 0.005), and mean transvalvular gradient increased from 19.1 +/- 5.1 mm Hg at rest to 33.2 +/- 7.7 mm Hg at maximum stress (p < 0.0001). Regression analyses demonstrated that maximum-stress gradient was independent of all variables except resting gradients (p < 0.004). Body surface area had no effect on the changes in cardiac output, effective orifice area, or transprosthetic gradient at maximum stress. CONCLUSIONS These data show that the 21-mm Medtronic Intact aortic prosthesis exhibits acceptable hemodynamic performance. Transvalvular gradients remained within a clinically acceptable range, both at rest and at maximum stress. Moreover, overall hemodynamic performance suggests that patient-prosthesis mismatch is unlikely to be a problem of clinical importance when this prosthesis is used.
Collapse
Affiliation(s)
- I Kadir
- Bristol Heart Institute, Department of Clinical Radiology, University of Bristol, United Kingdom
| | | | | | | | | | | |
Collapse
|
36
|
Abstract
Three hundred and twenty-six patients underwent CarboMedics valve implantation (CM) in the aortic (119 patients), mitral (148 patients) or aortic and mitral (59 patients) positions while 371 patients underwent St. Jude Medical valve implantation (SJ) in the aortic (113 patients), mitral (184 patient), or aortic and mitral (74 patients) positions at National Taiwan University Hospital from August 1991 through 1995. All patients received warfarin (Coumadin) anticoagulation with the target international normalized ratio around 1.5. The hospital mortality was 3.7% in the CM group and 4.3% in the SJ group. In the CM group at 5 years, the actuarial freedom from thromboembolism, valve thrombosis, and anticoagulant-related hemorrhage was 89.91 +/- 2.66%, 95. 23 +/- 1.50%, and 99.62 +/- 0.37%, respectively, and the actuarial survival rate was 90.4 +/- 1.6%. In the SJ group at 5 years, the actuarial freedom from thromboembolism, valve thrombosis, and anticoagulant-related hemorrhage was 94.79% +/- 1.70%, 98.80 +/- 0.72%, and 99.68 +/- 0.31%, respectively, and the actuarial survival rate was 91.3 +/- 1.7%. We therefore concluded that a similar survival rate was noted in the CM and SJ groups. With low dose anticoagulation, the complications of thromboembolism, valve thrombosis, and anticoagulant-related hemorrhage were low in the SJ group.
Collapse
Affiliation(s)
- S S Wang
- Department of Surgery, National Taiwan University, Taipei
| | | | | | | |
Collapse
|