1
|
BAŞ B, Gökay NY, Aydoğan Z, Yücel E. Do auditory brainstem implants favor the development of sensory integration and cognitive functions? Brain Behav 2024; 14:e3637. [PMID: 39099332 PMCID: PMC11298688 DOI: 10.1002/brb3.3637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 04/22/2024] [Accepted: 07/05/2024] [Indexed: 08/06/2024] Open
Abstract
BACKGROUND Information about the development of cognitive skills and the effect of sensory integration in children using auditory brainstem implants (ABIs) is still limited. OBJECTIVE This study primarily aims to investigate the relationship between sensory processing skills and attention and memory abilities in children with ABI, and secondarily aims to examine the effects of implant duration on sensory processing and cognitive skills in these children. METHODS The study included 25 children between the ages of 6 and 10 years (mean age: 14 girls and 11 boys) with inner ear and/or auditory nerve anomalies using auditory brainstem implants. Visual-Aural Digit Span Test B, Marking Test, Dunn Sensory Profile Questionnaire were applied to all children. RESULTS The sensory processing skills of children are statistically significant and positive, and moderately related to their cognitive skills. As the duration of implant use increases, better attention and memory performances have been observed (p < .05). CONCLUSION The study demonstrated the positive impact of sensory processing on the development of memory and attention skills in children with ABI. It will contribute to evaluating the effectiveness of attention, memory, and sensory integration skills, and aiding in the development of more effective educational strategies for these children.
Collapse
Affiliation(s)
- Banu BAŞ
- Faculty of Health Sciences, Department of AudiologyAnkara Yıldırım Beyazıt UniversityAnkaraTurkey
| | | | - Zehra Aydoğan
- Faculty of Health Sciences, Department of AudiologyAnkara UniversityAnkaraTurkey
| | - Esra Yücel
- Faculty of Health Sciences, Department of AudiologyHacettepe UniversityAnkaraTurkey
| |
Collapse
|
2
|
Carnicer-Lombarte A, Chen ST, Malliaras GG, Barone DG. Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics. Front Bioeng Biotechnol 2021; 9:622524. [PMID: 33937212 PMCID: PMC8081831 DOI: 10.3389/fbioe.2021.622524] [Citation(s) in RCA: 142] [Impact Index Per Article: 47.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 03/19/2021] [Indexed: 12/04/2022] Open
Abstract
The implantation of any foreign material into the body leads to the development of an inflammatory and fibrotic process-the foreign body reaction (FBR). Upon implantation into a tissue, cells of the immune system become attracted to the foreign material and attempt to degrade it. If this degradation fails, fibroblasts envelop the material and form a physical barrier to isolate it from the rest of the body. Long-term implantation of medical devices faces a great challenge presented by FBR, as the cellular response disrupts the interface between implant and its target tissue. This is particularly true for nerve neuroprosthetic implants-devices implanted into nerves to address conditions such as sensory loss, muscle paralysis, chronic pain, and epilepsy. Nerve neuroprosthetics rely on tight interfacing between nerve tissue and electrodes to detect the tiny electrical signals carried by axons, and/or electrically stimulate small subsets of axons within a nerve. Moreover, as advances in microfabrication drive the field to increasingly miniaturized nerve implants, the need for a stable, intimate implant-tissue interface is likely to quickly become a limiting factor for the development of new neuroprosthetic implant technologies. Here, we provide an overview of the material-cell interactions leading to the development of FBR. We review current nerve neuroprosthetic technologies (cuff, penetrating, and regenerative interfaces) and how long-term function of these is limited by FBR. Finally, we discuss how material properties (such as stiffness and size), pharmacological therapies, or use of biodegradable materials may be exploited to minimize FBR to nerve neuroprosthetic implants and improve their long-term stability.
Collapse
Affiliation(s)
- Alejandro Carnicer-Lombarte
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Shao-Tuan Chen
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - George G. Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Damiano G. Barone
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
- Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
3
|
Gundelach LA, Hüser MA, Beutner D, Ruther P, Bruegmann T. Towards the clinical translation of optogenetic skeletal muscle stimulation. Pflugers Arch 2020; 472:527-545. [PMID: 32415463 PMCID: PMC7239821 DOI: 10.1007/s00424-020-02387-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 03/05/2020] [Accepted: 04/28/2020] [Indexed: 12/27/2022]
Abstract
Paralysis is a frequent phenomenon in many diseases, and to date, only functional electrical stimulation (FES) mediated via the innervating nerve can be employed to restore skeletal muscle function in patients. Despite recent progress, FES has several technical limitations and significant side effects. Optogenetic stimulation has been proposed as an alternative, as it may circumvent some of the disadvantages of FES enabling cell type–specific, spatially and temporally precise stimulation of cells expressing light-gated ion channels, commonly Channelrhodopsin2. Two distinct approaches for the restoration of skeletal muscle function with optogenetics have been demonstrated: indirect optogenetic stimulation through the innervating nerve similar to FES and direct optogenetic stimulation of the skeletal muscle. Although both approaches show great promise, both have their limitations and there are several general hurdles that need to be overcome for their translation into clinics. These include successful gene transfer, sustained optogenetic protein expression, and the creation of optically active implantable devices. Herein, a comprehensive summary of the underlying mechanisms of electrical and optogenetic approaches is provided. With this knowledge in mind, we substantiate a detailed discussion of the advantages and limitations of each method. Furthermore, the obstacles in the way of clinical translation of optogenetic stimulation are discussed, and suggestions on how they could be overcome are provided. Finally, four specific examples of pathologies demanding novel therapeutic measures are discussed with a focus on the likelihood of direct versus indirect optogenetic stimulation.
Collapse
Affiliation(s)
- Lili A Gundelach
- Institute of Cardiovascular Physiology, University Medical Center, Göttingen, Germany
| | - Marc A Hüser
- Institute of Cardiovascular Physiology, University Medical Center, Göttingen, Germany
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center, Göttingen, Germany
| | - Dirk Beutner
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center, Göttingen, Germany
| | - Patrick Ruther
- Microsystem Materials Laboratory, Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
- BrainLinks-BrainTools Cluster of Excellence at the University of Freiburg, Freiburg, Germany
| | - Tobias Bruegmann
- Institute of Cardiovascular Physiology, University Medical Center, Göttingen, Germany.
- DZHK e.V. (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany.
| |
Collapse
|
4
|
Tarabichi O, Kanumuri VV, Klug J, Vachicouras N, Duarte MJ, Epprecht L, Kozin ED, Reinshagen K, Lacour SP, Brown MC, Lee DJ. Three-Dimensional Surface Reconstruction of the Human Cochlear Nucleus: Implications for Auditory Brain Stem Implant Design. J Neurol Surg B Skull Base 2020; 81:114-120. [PMID: 32206528 DOI: 10.1055/s-0039-1677863] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Accepted: 12/15/2018] [Indexed: 10/27/2022] Open
Abstract
Objective The auditory brain stem implant (ABI) is a neuroprosthesis placed on the surface of the cochlear nucleus (CN) to provide hearing sensations in children and adults who are not candidates for cochlear implantation. Contemporary ABI arrays are stiff and do not conform to the curved brain stem surface. Recent advancements in microfabrication techniques have enabled the development of flexible surface arrays, but these have only been applied in animal models. Herein, we measure the surface curvature of the human CN and adjoining regions to assist in the design and placement of next-generation conformable clinical ABI arrays. Three-dimensional (3D) reconstructions from ultrahigh T1-weighted brain magnetic resonance imaging (MRI) sequences and histologic reconstructions based on postmortem adult human brain stem specimens were used. Design This is a retrospective review of radiologic data and postmortem histologic axial sections. Setting This is set at the tertiary referral center. Participants Data were acquired from healthy adults. Main Outcome Measures The main outcome measures are principal curvature values (Kmin and Kmax) and global radius of curvature. Results The CN was successfully extracted and rendered as a 3D surface in all cases. Significant curvatures of the CN in both histologic and radiographic reconstructions were found with global radius of curvature ranging from 2.08 to 8.5 mm. In addition, local curvature analysis revealed that the surface is highly complex. Conclusion Detailed rendering of the human CN is feasible using histology and 3D MRI reconstruction and highlights complex surface topography that is not recapitulated by contemporary stiff ABI arrays.
Collapse
Affiliation(s)
- Osama Tarabichi
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States
| | - Vivek V Kanumuri
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States.,Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts, United States
| | - Julian Klug
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States.,Faculty of Medicine, University of Geneva, Switzerland
| | - Nicolas Vachicouras
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Centre for Neuroprostheses, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | - Maria J Duarte
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States
| | - Lorenz Epprecht
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States
| | - Elliott D Kozin
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States.,Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts, United States
| | - Katherine Reinshagen
- Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States
| | - Stéphanie P Lacour
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Centre for Neuroprostheses, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | - M Christian Brown
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States.,Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts, United States
| | - Daniel J Lee
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States.,Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts, United States
| |
Collapse
|
5
|
Guex AA, Hight AE, Narasimhan S, Vachicouras N, Lee DJ, Lacour SP, Brown MC. Auditory brainstem stimulation with a conformable microfabricated array elicits responses with tonotopically organized components. Hear Res 2019; 377:339-352. [PMID: 30867111 DOI: 10.1016/j.heares.2019.02.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 01/11/2019] [Accepted: 02/22/2019] [Indexed: 02/07/2023]
Abstract
Auditory brainstem implants (ABIs) restore hearing to deaf individuals not eligible for cochlear implants. Speech comprehension in ABI users is generally poor compared to that of cochlear implant users, and side effects are common. The poor performance may result from activating broad areas and multiple neuronal populations of the cochlear nucleus, however detailed studies of the responses to surface stimulation of the cochlear nucleus are lacking. A conformable electrode array was microfabricated to fit on the rat's dorsal cochlear nucleus (DCN). It hosts 20 small electrodes (each 100 μm diam.). The array was tested by recording evoked potentials and neural activity along the tonotopic axis of the inferior colliculus (IC). Almost all bipolar electrode pairs elicited responses, in some cases with an even, or relatively constant, pattern of thresholds and supra-threshold measures along the long axis of the array. This pattern suggests that conformable arrays can provide relatively constant excitation along the surface of the DCN and thus might decrease the ABI side effects caused by spread of high current to adjacent structures. We also examined tonotopic patterns of the IC responses. Compared to sound-evoked responses, electrically-evoked response mappings had less tonotopic organization and were broader in width. They became more tonotopic when the evoked activity common to all electrodes and the late phase of response were subtracted out, perhaps because the remaining activity is from tonotopically organized principal cells of the DCN. Responses became less tonotopic when inter-electrode distance was increased from 400 μm to 800 μm but were relatively unaffected by changing to monopolar stimulation. The results illustrate the challenges of using a surface array to present tonotopic cues and improve speech comprehension in humans who use the ABI.
Collapse
Affiliation(s)
- Amélie A Guex
- Laboratory for Soft Bioelectronic Interfaces, Centre for Neuroprosthetics, School of Engineering, Institute of Microengineering & Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | - Ariel Edward Hight
- Eaton-Peabody Laboratories and Department of Otolaryngology, Head and Neck Surgery, Massachusetts Eye and Ear, and Department of Otology and Laryngology, Harvard Medical School, Boston, MA, USA
| | - Shreya Narasimhan
- Eaton-Peabody Laboratories and Department of Otolaryngology, Head and Neck Surgery, Massachusetts Eye and Ear, and Department of Otology and Laryngology, Harvard Medical School, Boston, MA, USA
| | - Nicolas Vachicouras
- Laboratory for Soft Bioelectronic Interfaces, Centre for Neuroprosthetics, School of Engineering, Institute of Microengineering & Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | - Daniel J Lee
- Eaton-Peabody Laboratories and Department of Otolaryngology, Head and Neck Surgery, Massachusetts Eye and Ear, and Department of Otology and Laryngology, Harvard Medical School, Boston, MA, USA
| | - Stéphanie P Lacour
- Laboratory for Soft Bioelectronic Interfaces, Centre for Neuroprosthetics, School of Engineering, Institute of Microengineering & Institute of Bioengineering, Ecole Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | - M Christian Brown
- Eaton-Peabody Laboratories and Department of Otolaryngology, Head and Neck Surgery, Massachusetts Eye and Ear, and Department of Otology and Laryngology, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
6
|
McCreery D, Yadev K, Han M. Responses of neurons in the feline inferior colliculus to modulated electrical stimuli applied on and within the ventral cochlear nucleus; Implications for an advanced auditory brainstem implant. Hear Res 2018; 363:85-97. [PMID: 29573880 DOI: 10.1016/j.heares.2018.03.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2017] [Revised: 03/01/2018] [Accepted: 03/06/2018] [Indexed: 11/25/2022]
Abstract
Auditory brainstem implants (ABIs) can restore useful hearing to persons with deafness who cannot benefit from cochlear implants. However, the quality of hearing restored by ABIs rarely is comparable to that provided by cochlear implants in persons for whom those are appropriate. In an animal model, we evaluated elements of a prototype of an ABI in which the functions of macroelectrodes on the surface of the dorsal cochlear nucleus would be integrated with the function of multiple penetrating microelectrodes implanted into the ventral cochlear nucleus. The surface electrodes would convey most of the range of loudness percepts while the intranuclear microelectrodes would sharpen and focus pitch percepts. In the present study, stimulating electrodes were implanted chronically on the surface of the animal's dorsal cochlear nucleus (DCN) and also within their ventral cochlear nucleus (VCN). Recording microelectrodes were implanted into the central nucleus of the inferior colliculus (ICC). The electrical stimuli were sinusoidally modulated stimulus pulse trains applied on the DCN and within the VCN. Temporal encoding of neuronal responses was quantified as vector strength (VS) and as full-cycle rate of neuronal activity in the ICC. VS and full-cycle AP rate were measured for 4 stimulation modes; continuous and transient amplitude modulation of the stimulus pulse trains, each delivered via the macroelectrode on the surface of the DCN and then by the intranuclear penetrating microelectrodes. In the proposed clinical device the functions of the surface and intranuclear microelectrodes could best be integrated if there is minimal variation in the neuronal responses across the range of modulation depth, modulation frequencies, and across the four stimulation modes. In this study VS did vary as much as 34% across modulation frequency and modulation depth within a stimulation mode, and up to 40% between modulation modes. However, these intra- and inter-mode variances differed for different stimulation rates, and at 500 Hz the inter-mode differences in VS and across the range of modulation frequencies and modulation depths was<Roman> = </Roman>24% and the intra-modal differences were<Roman> = </Roman>15%. The findings were generally similar for rate encoding of modulation depth, although the depth of transient amplitude modulation delivered by the surface electrode was weakly encoded as full-cycle rate. Overall, our findings support the concept of a clinical ABI that employs surface stimulation and intranuclear microstimulation in an integrated manner.
Collapse
Affiliation(s)
- Douglas McCreery
- Neural Engineering Program at Huntington Medical Research Institutes, 734 Fairmount Ave, Pasadena, CA 91105, USA.
| | - Kamal Yadev
- Rigetti Computing, 775Heinz Avenue, Berkeley, CA 94710, USA.
| | - Martin Han
- Biomedical Engineering Department, School of Engineering & Institute of Material Sciences, The University of Connecticut at Storrs, 260Glenbrook Rd, Unit 3247, Storrs, Connecticut 06269-3247, USA.
| |
Collapse
|
7
|
Abstract
The first medical device to restore a human sense, a cochlear implant converts sound into a train of current pulses that directly stimulate the auditory nerve of a profoundly deaf ear.
Collapse
|
8
|
|
9
|
Moser T. Optogenetic stimulation of the auditory pathway for research and future prosthetics. Curr Opin Neurobiol 2015; 34:29-36. [PMID: 25637880 DOI: 10.1016/j.conb.2015.01.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Accepted: 01/09/2015] [Indexed: 01/13/2023]
Abstract
Sound is encoded by spiral ganglion neurons (SGNs) in the hearing organ, the cochlea, with great temporal, spectral and intensity resolution. When hearing fails, electric stimulation by implanted prostheses can partially restore hearing. Optical stimulation promises a fundamental advance of hearing restoration over electric prostheses since light can be conveniently focused and hence might dramatically improve frequency resolution of sound encoding. Combining optogenetic manipulation of neurons with innovative optical stimulation technology promises versatile spatiotemporal stimulation patterns in the auditory system. Therefore, using optical stimulation of SGNs also has great potential for auditory research. Here, I review recent progress in optogenetic stimulation of the auditory system and its potential for future application in research and hearing restoration.
Collapse
Affiliation(s)
- Tobias Moser
- Institute for Auditory Neuroscience and Collaborative Research Center 889, University Medical Center Göttingen, Göttingen, Germany; Bernstein Center for Computational Neuroscience, University of Göttingen, Göttingen, Germany; Center for Nanoscale Microscopy and Molecular Physiology of the Brain, University of Göttingen, Göttingen, Germany.
| |
Collapse
|
10
|
Offutt SJ, Ryan KJ, Konop AE, Lim HH. Suppression and facilitation of auditory neurons through coordinated acoustic and midbrain stimulation: investigating a deep brain stimulator for tinnitus. J Neural Eng 2014; 11:066001. [PMID: 25307351 PMCID: PMC4244264 DOI: 10.1088/1741-2560/11/6/066001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVE The inferior colliculus (IC) is the primary processing center of auditory information in the midbrain and is one site of tinnitus-related activity. One potential option for suppressing the tinnitus percept is through deep brain stimulation via the auditory midbrain implant (AMI), which is designed for hearing restoration and is already being implanted in deaf patients who also have tinnitus. However, to assess the feasibility of AMI stimulation for tinnitus treatment we first need to characterize the functional connectivity within the IC. Previous studies have suggested modulatory projections from the dorsal cortex of the IC (ICD) to the central nucleus of the IC (ICC), though the functional properties of these projections need to be determined. APPROACH In this study, we investigated the effects of electrical stimulation of the ICD on acoustic-driven activity within the ICC in ketamine-anesthetized guinea pigs. MAIN RESULTS We observed ICD stimulation induces both suppressive and facilitatory changes across ICC that can occur immediately during stimulation and remain after stimulation. Additionally, ICD stimulation paired with broadband noise stimulation at a specific delay can induce greater suppressive than facilitatory effects, especially when stimulating in more rostral and medial ICD locations. SIGNIFICANCE These findings demonstrate that ICD stimulation can induce specific types of plastic changes in ICC activity, which may be relevant for treating tinnitus. By using the AMI with electrode sites positioned with the ICD and the ICC, the modulatory effects of ICD stimulation can be tested directly in tinnitus patients.
Collapse
Affiliation(s)
- Sarah J. Offutt
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, USA
| | - Kellie J. Ryan
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, USA
| | - Alexander E. Konop
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, USA
| | - Hubert H. Lim
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, USA
- Institute for Translational Neuroscience, University of Minnesota, Minneapolis, USA
- Department of Otolaryngology, Head and Neck Surgery, University of Minnesota, Minneapolis, USA
| |
Collapse
|
11
|
Kachniarz B, Chen JX, Gilani S, Shin JJ. Diagnostic yield of MRI for pediatric hearing loss: a systematic review. Otolaryngol Head Neck Surg 2014; 152:5-22. [PMID: 25389321 DOI: 10.1177/0194599814555837] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To perform a systematic review to analyze the diagnostic yield of magnetic resonance imaging (MRI) for pediatric hearing loss, including comparison to computed tomography (CT) and subgroup evaluation according to impairment severity and specific diagnostic findings (cochlear anomalies, enlarged vestibular aqueduct, cochlear nerve abnormalities, and brain findings). DATA SOURCES Pubmed, EMBASE, and the Cochrane library were assessed from their inception through December 2013. Manual searches were also performed, and topic experts were contacted. REVIEW METHODS Data from studies describing the use of MRI with or without comparison to CT in the diagnostic evaluation of pediatric patients with hearing loss were evaluated, according to a priori inclusion/exclusion criteria. Two independent evaluators corroborated the extracted data. Heterogeneity was evaluated according to the I(2) statistic. RESULTS There were 29 studies that evaluated 2434 patients with MRIs and 1451 patients with CTs that met inclusion/exclusion criteria. There was a wide range of diagnostic yield from MRI. Heterogeneity among studies was substantial but improved with subgroup analysis. Meta-analysis of yield differences demonstrated that CT had a greater yield than MRI for enlarged vestibular aqueduct (yield difference 16.7% [95% CI, 9.1%-24.4%]) and a borderline advantage for cochlear anomalies (4.7% [95% CI, 0.1%-9.5%]). Studies were more likely to report brain findings with MRI. CONCLUSIONS These data may be utilized in concert with that from studies of risks of MRI and risk/yield of CT to inform the choice of diagnostic testing.
Collapse
Affiliation(s)
| | - Jenny X Chen
- Harvard Medical School, Boston, Massachusetts, USA
| | | | | |
Collapse
|
12
|
Mandalà M, Colletti L, Colletti G, Colletti V. Improved outcomes in auditory brainstem implantation with the use of near-field electrical compound action potentials. Otolaryngol Head Neck Surg 2014; 151:1008-13. [PMID: 25257904 DOI: 10.1177/0194599814551151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To compare the outcomes (auditory threshold and open-set speech perception at 48-month follow-up) of a new near-field monitoring procedure, electrical compound action potential, on positioning the auditory brainstem implant electrode array on the surface of the cochlear nuclei versus the traditional far-field electrical auditory brainstem response. STUDY DESIGN Retrospective study. SETTING Tertiary referral center. SUBJECTS AND METHODS Among the 202 patients with auditory brainstem implants fitted and monitored with electrical auditory brainstem response during implant fitting, 9 also underwent electrical compound action potential recording. These subjects were matched retrospectively with a control group of 9 patients in whom only the electrical auditory brainstem response was recorded. Electrical compound action potentials were obtained using a cotton-wick recording electrode located near the surface of the cochlear nuclei and on several cranial nerves. RESULTS Significantly lower potential thresholds were observed with the recording electrode located on the cochlear nuclei surface compared with the electrical auditory brainstem response (104.4 ± 32.5 vs 158.9 ± 24.2, P = .0030). Electrical brainstem response and compound action potentials identified effects on the neighboring cranial nerves on 3.2 ± 2.4 and 7.8 ± 3.2 electrodes, respectively (P = .0034). Open-set speech perception outcomes at 48-month follow-up had improved significantly in the near- versus far-field recording groups (78.9% versus 56.7%; P = .0051). CONCLUSIONS Electrical compound action potentials during auditory brainstem implantation significantly improved the definition of the potential threshold and the number of auditory and extra-auditory waves generated. It led to the best coupling between the electrode array and cochlear nuclei, significantly improving the overall open-set speech perception.
Collapse
Affiliation(s)
| | | | - Giacomo Colletti
- Department of Maxillo-Facial Surgery, University of Milan, Milan, Italy
| | | |
Collapse
|
13
|
Straka MM, McMahon M, Markovitz CD, Lim HH. Effects of location and timing of co-activated neurons in the auditory midbrain on cortical activity: implications for a new central auditory prosthesis. J Neural Eng 2014; 11:046021. [PMID: 25003629 DOI: 10.1088/1741-2560/11/4/046021] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE An increasing number of deaf individuals are being implanted with central auditory prostheses, but their performance has generally been poorer than for cochlear implant users. The goal of this study is to investigate stimulation strategies for improving hearing performance with a new auditory midbrain implant (AMI). Previous studies have shown that repeated electrical stimulation of a single site in each isofrequency lamina of the central nucleus of the inferior colliculus (ICC) causes strong suppressive effects in elicited responses within the primary auditory cortex (A1). Here we investigate if improved cortical activity can be achieved by co-activating neurons with different timing and locations across an ICC lamina and if this cortical activity varies across A1. APPROACH We electrically stimulated two sites at different locations across an isofrequency ICC lamina using varying delays in ketamine-anesthetized guinea pigs. We recorded and analyzed spike activity and local field potentials across different layers and locations of A1. RESULTS Co-activating two sites within an isofrequency lamina with short inter-pulse intervals (<5 ms) could elicit cortical activity that is enhanced beyond a linear summation of activity elicited by the individual sites. A significantly greater extent of normalized cortical activity was observed for stimulation of the rostral-lateral region of an ICC lamina compared to the caudal-medial region. We did not identify any location trends across A1, but the most cortical enhancement was observed in supragranular layers, suggesting further integration of the stimuli through the cortical layers. SIGNIFICANCE The topographic organization identified by this study provides further evidence for the presence of functional zones across an ICC lamina with locations consistent with those identified by previous studies. Clinically, these results suggest that co-activating different neural populations in the rostral-lateral ICC rather than the caudal-medial ICC using the AMI may improve or elicit different types of hearing capabilities.
Collapse
Affiliation(s)
- Małgorzata M Straka
- Department of Biomedical Engineering, University of Minnesota, Twin Cities 312 Church St SE, Minneapolis, MN 55455, USA
| | | | | | | |
Collapse
|
14
|
Wu CC, Luo X. Electrode spanning with partial tripolar stimulation mode in cochlear implants. J Assoc Res Otolaryngol 2014; 15:1023-36. [PMID: 24865767 DOI: 10.1007/s10162-014-0464-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Accepted: 05/07/2014] [Indexed: 11/26/2022] Open
Abstract
The perceptual effects of electrode spanning (i.e., the use of nonadjacent return electrodes) in partial tripolar (pTP) mode were tested on a main electrode EL8 in five cochlear implant (CI) users. Current focusing was controlled by σ (the ratio of current returned within the cochlea), and current steering was controlled by α (the ratio of current returned to the basal electrode). Experiment 1 tested whether asymmetric spanning with α = 0.5 can create additional channels around standard pTP stimuli. It was found that in general, apical spanning (i.e., returning current to EL6 rather than EL7) elicited a pitch between those of standard pTP stimuli on main electrodes EL8 and EL9, while basal spanning (i.e., returning current to EL10 rather than EL9) elicited a pitch between those of standard pTP stimuli on main electrodes EL7 and EL8. The pitch increase caused by apical spanning was more salient than the pitch decrease caused by basal spanning. To replace the standard pTP channel on the main electrode EL8 when EL7 or EL9 is defective, experiment 2 tested asymmetrically spanned pTP stimuli with various α, and experiment 3 tested symmetrically spanned pTP stimuli with various σ. The results showed that pitch increased with decreasing α in asymmetric spanning, or with increasing σ in symmetric spanning. Apical spanning with α around 0.69 and basal spanning with α around 0.38 may both elicit a similar pitch as the standard pTP stimulus. With the same σ, the symmetrically spanned pTP stimulus was higher in pitch than the standard pTP stimulus. A smaller σ was thus required for symmetric spanning to match the pitch of the standard pTP stimulus. In summary, electrode spanning is an effective field-shaping technique that is useful for adding spectral channels and handling defective electrodes with CIs.
Collapse
Affiliation(s)
- Ching-Chih Wu
- School of Electrical and Computer Engineering, Purdue University, 500 Oval Drive, West Lafayette, IN, 47907, USA,
| | | |
Collapse
|
15
|
Hu Z, Ulfendahl M. The potential of stem cells for the restoration of auditory function in humans. Regen Med 2014; 8:309-18. [PMID: 23627825 DOI: 10.2217/rme.13.32] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Hearing loss is one of the most common disabilities, affecting approximately 10% of the population. Hair cells and spiral ganglion neurons are usually damaged in most cases of hearing loss. Currently, there is virtually no biological approach to replace damaged hearing cells. Recent developments in stem cell technology provide new opportunities for the treatment of deafness. Two major strategies have been investigated: differentiation of endogenous stem cells into new hair cells; and introduction of exogenous cells into the inner ear to substitute injured hearing neurons. Although there is still a learning curve in stem cell-based replacement, the probability exists to utilize personalized stem cells to eventually provide a novel intervention for patients with deafness in future clinical research trials.
Collapse
Affiliation(s)
- Zhengqing Hu
- Department of Otolaryngology-HNS, Wayne State University, MI, USA.
| | | |
Collapse
|
16
|
Hernandez VH, Gehrt A, Reuter K, Jing Z, Jeschke M, Mendoza Schulz A, Hoch G, Bartels M, Vogt G, Garnham CW, Yawo H, Fukazawa Y, Augustine GJ, Bamberg E, Kügler S, Salditt T, de Hoz L, Strenzke N, Moser T. Optogenetic stimulation of the auditory pathway. J Clin Invest 2014; 124:1114-29. [PMID: 24509078 DOI: 10.1172/jci69050] [Citation(s) in RCA: 100] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 11/21/2013] [Indexed: 12/18/2022] Open
Abstract
Auditory prostheses can partially restore speech comprehension when hearing fails. Sound coding with current prostheses is based on electrical stimulation of auditory neurons and has limited frequency resolution due to broad current spread within the cochlea. In contrast, optical stimulation can be spatially confined, which may improve frequency resolution. Here, we used animal models to characterize optogenetic stimulation, which is the optical stimulation of neurons genetically engineered to express the light-gated ion channel channelrhodopsin-2 (ChR2). Optogenetic stimulation of spiral ganglion neurons (SGNs) activated the auditory pathway, as demonstrated by recordings of single neuron and neuronal population responses. Furthermore, optogenetic stimulation of SGNs restored auditory activity in deaf mice. Approximation of the spatial spread of cochlear excitation by recording local field potentials (LFPs) in the inferior colliculus in response to suprathreshold optical, acoustic, and electrical stimuli indicated that optogenetic stimulation achieves better frequency resolution than monopolar electrical stimulation. Virus-mediated expression of a ChR2 variant with greater light sensitivity in SGNs reduced the amount of light required for responses and allowed neuronal spiking following stimulation up to 60 Hz. Our study demonstrates a strategy for optogenetic stimulation of the auditory pathway in rodents and lays the groundwork for future applications of cochlear optogenetics in auditory research and prosthetics.
Collapse
|
17
|
|
18
|
Matthies C, Brill S, Varallyay C, Solymosi L, Gelbrich G, Roosen K, Ernestus RI, Helms J, Hagen R, Mlynski R, Shehata-Dieler W, Müller J. Auditory brainstem implants in neurofibromatosis Type 2: is open speech perception feasible? J Neurosurg 2013; 120:546-58. [PMID: 24329026 DOI: 10.3171/2013.9.jns12686] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Patients with bilateral auditory nerve destruction may perceive some auditory input with auditory brainstem implants (ABIs). Despite technological developments and trials in new stimulation sites, hearing is very variable and of limited quality. The goal of this study was to identify advantageous and critical factors that influence the quality of auditory function, especially speech perception. METHODS The authors conducted a prospective study on ABI operations performed with the aid of multimodality neuromonitoring between 2005 and 2009 in 18 patients with neurofibromatosis Type 2. Outcome was evaluated by testing word recognition (monotrochee-polysyllabic word test at auditory-only mode [MTPa]) and open speech perception (Hochmair-Schulz-Moser [HSM] sentence test), both in pure auditory mode. The primary outcome was the HSM score at 24 months. The predictive meaning of general clinical data, tumor volume, number of active electrodes, duration of deafness, and early hearing data was examined. RESULTS In 16 successful ABI activations the average score for MTPa was 89% (SD 13%), and for HSM it was 41% (SD 32%) at 24 months. There were 2 nonresponders, 1 after radiosurgery and the other in an anatomical variant. Direct facial nerve reconstruction during the same surgery was followed by successful nerve recovery in 2 patients, with a simultaneous very good HSM result. Patients' age, tumor extension, and tumor volume were not negative predictors. There was an inverse relationship between HSM scores and deafness duration; 50% or higher HSM scores were found only in patients with ipsilateral deafness duration up to 24 months. The higher the deafness sum of both sides, the less likely that any HSM score will be achieved (p = 0.034). In patients with total deafness duration of less than 240 months, higher numbers of active electrodes were significantly associated with better outcomes. The strongest cross-correlation was identified between early MTPa score at 3 months and 24-month HSM outcome. CONCLUSIONS This study documents that open-set speech recognition in pure auditory mode is feasible in patients with ABIs. Large tumor volumes do not prevent good outcome. Positive preconditions are short ipsilateral and short bilateral deafness periods and high number of auditory electrodes. Early ability in pure auditory word recognition tests indicates long-term capability of open speech perception.
Collapse
|
19
|
Calixto R, Salamat B, Rode T, Hartmann T, Volckaerts B, Ruther P, Lenarz T, Lim HH. Investigation of a new electrode array technology for a central auditory prosthesis. PLoS One 2013; 8:e82148. [PMID: 24312638 PMCID: PMC3846787 DOI: 10.1371/journal.pone.0082148] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Accepted: 10/30/2013] [Indexed: 11/21/2022] Open
Abstract
Ongoing clinical studies on patients recently implanted with the auditory midbrain implant (AMI) into the inferior colliculus (IC) for hearing restoration have shown that these patients do not achieve performance levels comparable to cochlear implant patients. The AMI consists of a single-shank array (20 electrodes) for stimulation along the tonotopic axis of the IC. Recent findings suggest that one major limitation in AMI performance is the inability to sufficiently activate neurons across the three-dimensional (3-D) IC. Unfortunately, there are no currently available 3-D array technologies that can be used for clinical applications. More recently, there has been a new initiative by the European Commission to fund and develop 3-D chronic electrode arrays for science and clinical applications through the NeuroProbes project that can overcome the bulkiness and limited 3-D configurations of currently available array technologies. As part of the NeuroProbes initiative, we investigated whether their new array technology could be potentially used for future AMI patients. Since the NeuroProbes technology had not yet been tested for electrical stimulation in an in vivo animal preparation, we performed experiments in ketamine-anesthetized guinea pigs in which we inserted and stimulated a NeuroProbes array within the IC and recorded the corresponding neural activation within the auditory cortex. We used 2-D arrays for this initial feasibility study since they were already available and were sufficient to access the IC and also demonstrate effective activation of the central auditory system. Based on these encouraging results and the ability to develop customized 3-D arrays with the NeuroProbes technology, we can further investigate different stimulation patterns across the ICC to improve AMI performance.
Collapse
Affiliation(s)
- Roger Calixto
- Institute of Audioneurotechnology and Department of Experimental Otology, Hannover Medical University, Hannover, Germany
- * E-mail:
| | - Behrouz Salamat
- Institute of Audioneurotechnology and Department of Experimental Otology, Hannover Medical University, Hannover, Germany
| | - Thilo Rode
- Institute of Audioneurotechnology and Department of Experimental Otology, Hannover Medical University, Hannover, Germany
| | - Tanja Hartmann
- Institute of Audioneurotechnology and Department of Experimental Otology, Hannover Medical University, Hannover, Germany
| | | | - Patrick Ruther
- Department of Microsystems Engineering (IMTEK) at the University of Freiburg, Freiburg, Germany
| | - Thomas Lenarz
- Institute of Audioneurotechnology and Department of Experimental Otology, Hannover Medical University, Hannover, Germany
| | - Hubert H. Lim
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota
| |
Collapse
|
20
|
McCreery D, Han M, Pikov V, Yadav K, Pannu S. Encoding of the amplitude modulation of pulsatile electrical stimulation in the feline cochlear nucleus by neurons in the inferior colliculus; effects of stimulus pulse rate. J Neural Eng 2013; 10:056010. [PMID: 23928683 DOI: 10.1088/1741-2560/10/5/056010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVES Persons without a functional auditory nerve cannot benefit from cochlear implants, but some hearing can be restored by an auditory brainstem implant (ABI) with stimulating electrodes implanted on the surface of the cochlear nucleus (CN). Most users benefit from their ABI, but speech recognition tends to be poorer than for users of cochlear implants. Psychophysical studies suggest that poor modulation detection may contribute to the limited performance of ABI users. In a cat model, we determined how the pulse rate of the electrical stimulus applied within or on the CN affects temporal and rate encoding of amplitude modulation (AM) by neurons in the central nucleus of the inferior colliculus (ICC). APPROACH Stimulating microelectrodes were implanted chronically in and on the cats' CN, and multi-site recording microelectrodes were implanted chronically into the ICC. Encoding of AM pulse trains by neurons in the ICC was characterized as vector strength (VS), the synchrony of neural activity with the AM, and as the mean rate of neuronal action potentials (neuronal spike rate (NSR)). MAIN RESULTS For intranuclear microstimulation, encoding of AM as VS was up to 3 dB greater when stimulus pulse rate was increased from 250 to 500 pps, but only for neuronal units with low best acoustic frequencies, and when the electrical stimulation was modulated at low frequencies (10-20 Hz). For stimulation on the surface of the CN, VS was similar at 250 and 500 pps, and the dynamic range of the VS was reduced for pulse rates greater than 250 pps. Modulation depth was encoded strongly as VS when the maximum stimulus amplitude was held constant across a range of modulation depth. This 'constant maximum' protocol allows enhancement of modulation depth while preserving overall dynamic range. However, modulation depth was not encoded as strongly as NSR. SIGNIFICANCE The findings have implications for improved sound processors for present and future ABIs. The performance of ABIs may benefit from using pulse rates greater than those presently used in most ABIs, and by sound processing strategies that enhance the modulation depth of the electrical stimulus while preserving dynamic range.
Collapse
|
21
|
Straka MM, Schendel D, Lim HH. Neural integration and enhancement from the inferior colliculus up to different layers of auditory cortex. J Neurophysiol 2013; 110:1009-20. [PMID: 23719210 DOI: 10.1152/jn.00022.2013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
While the cochlear implant has successfully restored hearing to many deaf patients, it cannot benefit those without a functional auditory nerve or an implantable cochlea. As an alternative, the auditory midbrain implant (AMI) has been developed and implanted into deaf patients. Consisting of a single-shank array, the AMI is designed for stimulation along the tonotopic gradient of the inferior colliculus (ICC). Although the AMI can provide frequency cues, it appears to insufficiently transmit temporal cues for speech understanding because repeated stimulation of a single site causes strong suppressive and refractory effects. Applying the electrical stimulation to at least two sites within an isofrequency lamina can circumvent these refractory processes. Moreover, coactivation with short intersite delays (<5 ms) can elicit cortical activation which is enhanced beyond the summation of activity induced by the individual sites. The goal of our study was to further investigate the role of the auditory cortex in this enhancement effect. In guinea pigs, we electrically stimulated two locations within an ICC lamina or along different laminae with varying interpulse intervals (0-10 ms) and recorded activity in different locations and layers of primary auditory cortex (A1). Our findings reveal a neural mechanism that integrates activity only from neurons located within the same ICC lamina for short spiking intervals (<6 ms). This mechanism leads to enhanced activity into layers III-V of A1 that is further magnified in supragranular layers. This integration mechanism may contribute to perceptual coding of different sound features that are relevant for improving AMI performance.
Collapse
Affiliation(s)
- Malgorzata M Straka
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minneapolis, Minnesota, USA.
| | | | | |
Collapse
|
22
|
Deltenre P, Van Maldergem L. Hearing loss and deafness in the pediatric population. HANDBOOK OF CLINICAL NEUROLOGY 2013; 113:1527-38. [DOI: 10.1016/b978-0-444-59565-2.00023-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
23
|
Matthies C, Brill S, Kaga K, Morita A, Kumakawa K, Skarzynski H, Claassen A, Hui Y, Chiong C, Müller J, Behr R. Auditory Brainstem Implantation Improves Speech Recognition in Neurofibromatosis Type II Patients. ACTA ACUST UNITED AC 2013; 75:282-95. [DOI: 10.1159/000350568] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2012] [Accepted: 10/22/2012] [Indexed: 11/19/2022]
|
24
|
Mauger SJ, Shivdasani MN, Rathbone GD, Paolini AG. An in vivo investigation of inferior colliculus single neuron responses to cochlear nucleus pulse train stimulation. J Neurophysiol 2012; 108:2999-3008. [PMID: 22972959 DOI: 10.1152/jn.01087.2011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The auditory brain stem implant (ABI) is being used clinically to restore hearing to patients unable to benefit from a cochlear implant (CI). Speech perception outcomes for ABI users are typically poor compared with most CI users. The ABI is implanted either on the surface of or penetrating through the cochlear nucleus in the auditory brain stem and uses stimulation strategies developed for auditory nerve stimulation with a CI. Although the stimulus rate may affect speech perception outcomes with current stimulation strategies, no studies have systematically investigated the effect of stimulus rate electrophysiologically or clinically. We therefore investigated rate response properties and temporal response properties of single inferior colliculus (IC) neurons from penetrating ABI stimulation using stimulus rates ranging from 100 to 1,600 pulses/s in the rat. We found that the stimulus rate affected the proportion of response types, thresholds, and dynamic ranges of IC activation. The stimulus rate was also found to affect the temporal properties of IC responses, with higher rates providing more temporally similar responses to acoustic stimulation. Suppression of neural firing and inhibition in IC neurons was also found, with response properties varying with the stimulus rate. This study demonstrated that changes in the ABI stimulus rate results in significant differences in IC neuron response properties. Due to electrophysiological differences, the stimulus rate may also change perceptual properties. We suggest that clinical evaluation of the ABI stimulus rate should be performed.
Collapse
Affiliation(s)
- Stefan J Mauger
- School of Psychological Science, La Trobe University, Melbourne, Victoria, Australia
| | | | | | | |
Collapse
|
25
|
Rosahl SK, Rosahl S. No easy target: anatomic constraints of electrodes interfacing the human cochlear nucleus. Neurosurgery 2012; 72:58-64; discussion 65. [PMID: 22895407 DOI: 10.1227/neu.0b013e31826cde82] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Auditory brainstem implants have failed to produce consistent clinical results comparable to those with the cochlear implant, both with surface and penetrating electrodes. OBJECTIVE To determine neuromorphological constraints of the auditory brainstem implant interface. METHODS The size, shape, surface depth, and spatial orientation of 33 human cochlear nuclei in 20 brainstem specimens obtained at autopsy were systematically analyzed in 792 slices each with a thickness of 8 μm. Three-dimensional renderings of the cochlear nucleus complex were obtained from a true-to-scale model, and the resulting photographic views were arranged according to the axes of the brainstem. RESULTS The dimensions of the ventral and dorsal cochlear nuclei in the axial, coronal, and sagittal planes correlated linearly with each other. There were no significant side differences. Maximum dimensions of the whole cochlear nuclear complex were 8.01 × 1.53 × 3.76 mm. The appearance of the ventral and dorsal nuclei combined resembles a distorted X shape from a lateral view and an angulated wedge shape when viewed from above. Slanted into the depth of the brainstem above the facial nerve entrance, the superior boundary of the ventral nucleus is located more than 7 mm off the surface of the brainstem on average. CONCLUSION In the absence of appropriate surface landmarks and imaging guidance, to gain tonotopic access to the human cochlear nucleus with surface and depth electrode remains a major challenge. Due to its location close to the surface, the dorsal cochlear nucleus is vulnerable to surgical manipulation and to tumors.
Collapse
|
26
|
Calixto R, Lenarz M, Neuheiser A, Scheper V, Lenarz T, Lim HH. Coactivation of different neurons within an isofrequency lamina of the inferior colliculus elicits enhanced auditory cortical activation. J Neurophysiol 2012; 108:1199-210. [PMID: 22623485 DOI: 10.1152/jn.00111.2012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The phenomenal success of the cochlear implant (CI) is attributed to its ability to provide sufficient temporal and spectral cues for speech understanding. Unfortunately, the CI is ineffective for those without a functional auditory nerve or an implantable cochlea required for CI implementation. As an alternative, our group developed and implanted in deaf patients a new auditory midbrain implant (AMI) to stimulate the central nucleus of the inferior colliculus (ICC). Although the AMI can provide frequency cues, it appears to insufficiently transmit temporal cues for speech understanding. The three-dimensional ICC consists of two-dimensional isofrequency laminae. The single-shank AMI only stimulates one site in any given ICC lamina and does not exhibit enhanced activity (i.e., louder percepts or lower thresholds) for repeated pulses on the same site with intervals <2-5 ms, as occurs for CI pulse or acoustic click stimulation. This enhanced activation, related to short-term temporal integration, is important for tracking the rapid temporal fluctuations of a speech signal. Therefore, we investigated the effects of coactivation of different regions within an ICC lamina on primary auditory cortex activity in ketamine-anesthetized guinea pigs. Interestingly, our findings reveal an enhancement mechanism for integrating converging inputs from an ICC lamina on a fast scale (<6-ms window) that is compromised when stimulating just a single ICC location. Coactivation of two ICC regions also reduces the strong and long-term (>100 ms) suppressive effects induced by repeated stimulation of just a single location. Improving AMI performance may require at least two shanks implanted along the tonotopic gradient of the ICC that enables coactivation of multiple regions along an ICC lamina with the appropriate interstimulus delays.
Collapse
Affiliation(s)
- Roger Calixto
- Institute of Audioneurotechnology and Department of Experimental Otology, Hannover Medical University, Hannover, Germany
| | | | | | | | | | | |
Collapse
|
27
|
Manzoor NF, Gao Y, Licari F, Kaltenbach JA. Comparison and contrast of noise-induced hyperactivity in the dorsal cochlear nucleus and inferior colliculus. Hear Res 2012; 295:114-23. [PMID: 22521905 DOI: 10.1016/j.heares.2012.04.003] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Revised: 03/26/2012] [Accepted: 04/03/2012] [Indexed: 01/13/2023]
Abstract
Induction of hyperactivity in the central auditory system is one of the major physiological hallmarks of animal models of noise-induced tinnitus. Although hyperactivity occurs at various levels of the auditory system, it is not clear to what extent hyperactivity originating in one nucleus contributes to hyperactivity at higher levels of the auditory system. In this study we compared the time courses and tonotopic distribution patterns of hyperactivity in the dorsal cochlear nucleus (DCN) and inferior colliculus (IC). A model of acquisition of hyperactivity in the IC by passive relay from the DCN would predict that the two nuclei show similar time courses and tonotopic profiles of hyperactivity. A model of acquisition of hyperactivity in the IC by compensatory plasticity mechanisms would predict that the IC and DCN would show differences in these features, since each adjusts to changes of spontaneous activity of opposite polarity. To test the role of these two mechanisms, animals were exposed to an intense hyperactivity-inducing tone (10 kHz, 115 dB SPL, 4 h) then studied electrophysiologically at three different post-exposure recovery times (from 1 to 6 weeks after exposure). For each time frame, multiunit spontaneous activity was mapped as a function of location along the tonotopic gradient in the DCN and IC. Comparison of activity profiles from the two nuclei showed a similar progression toward increased activity over time and culminated in the development of a central peak of hyperactivity at a similar tonotopic location. These similarities suggest that the shape of the activity profile is determined primarily by passive relay from the cochlear nucleus. However, the absolute levels of activity were generally much lower in the IC than in the DCN, suggesting that the magnitude of hyperactivity is greatly attenuated by inhibition.
Collapse
Affiliation(s)
- N F Manzoor
- Department of Neurosciences, The Cleveland Clinic, NE-63, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | | | | | | |
Collapse
|
28
|
Bulkin DA, Groh JM. Systematic mapping of the monkey inferior colliculus reveals enhanced low frequency sound representation. J Neurophysiol 2011; 105:1785-97. [PMID: 21307328 PMCID: PMC3075276 DOI: 10.1152/jn.00857.2010] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2010] [Accepted: 02/03/2011] [Indexed: 11/22/2022] Open
Abstract
We investigated the functional architecture of the inferior colliculus (IC) in rhesus monkeys. We systematically mapped multiunit responses to tonal stimuli and noise in the IC and surrounding tissue of six rhesus macaques, collecting data at evenly placed locations and recording nonresponsive locations to define boundaries. The results show a modest tonotopically organized region (17 of 100 recording penetration locations in 4 of 6 monkeys) surrounded by a large mass of tissue that, although vigorously responsive, showed no clear topographic arrangement (68 of 100 penetration locations). Rather, most cells in these recordings responded best to frequencies at the low end of the macaque auditory range. The remaining 15 (of 100) locations exhibited auditory responses that were not sensitive to sound frequency. Potential anatomical correlates of functionally defined regions and implications for midbrain auditory prosthetic devices are discussed.
Collapse
Affiliation(s)
- David A Bulkin
- Department of Neurobiology, Duke University, Durham, NC 27708, USA.
| | | |
Collapse
|
29
|
Kaltenbach JA. Tinnitus: Models and mechanisms. Hear Res 2010; 276:52-60. [PMID: 21146597 DOI: 10.1016/j.heares.2010.12.003] [Citation(s) in RCA: 176] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2010] [Revised: 12/02/2010] [Accepted: 12/03/2010] [Indexed: 10/18/2022]
Abstract
Over the past decade, there has been a burgeoning of scientific interest in the neurobiological origins of tinnitus. During this period, numerous behavioral and physiological animal models have been developed which have yielded major clues concerning the likely neural correlates of acute and chronic forms of tinnitus and the processes leading to their induction. The data increasingly converge on the view that tinnitus is a systemic problem stemming from imbalances in the excitatory and inhibitory inputs to auditory neurons. Such changes occur at multiple levels of the auditory system and involve a combination of interacting phenomena that are triggered by loss of normal input from the inner ear. This loss sets in motion a number of plastic readjustments in the central auditory system and sometimes beyond the auditory system that culminate in the induction of aberrant states of activation that include hyperactivity, bursting discharges and increases in neural synchrony. This article will review was has been learned about the biological origins of these alterations, summarize where they occur and examine the cellular and molecular mechanisms that are most likely to underlie them.
Collapse
Affiliation(s)
- James A Kaltenbach
- Department of Neurosciences, NE-63, Lerner Research Institute/Head and Neck Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44122, USA.
| |
Collapse
|
30
|
|
31
|
Affiliation(s)
- Andrej Kral
- Institute of Audioneurotechnology and the Department of Experimental Otology, Ear, Nose, and Throat Clinics, Medical University Hannover, Hannover, Germany.
| | | |
Collapse
|
32
|
Stieglitz T. Neuroprothetik und Neuromodulation. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2010; 53:783-90. [DOI: 10.1007/s00103-010-1093-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
33
|
Konrad P, Shanks T. Implantable brain computer interface: Challenges to neurotechnology translation. Neurobiol Dis 2010; 38:369-75. [DOI: 10.1016/j.nbd.2009.12.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2009] [Revised: 09/18/2009] [Accepted: 12/08/2009] [Indexed: 10/20/2022] Open
|
34
|
McCreery D, Han M, Pikov V. Neuronal activity evoked in the inferior colliculus of the cat by surface macroelectrodes and penetrating microelectrodes implanted in the cochlear nucleus. IEEE Trans Biomed Eng 2010; 57:1765-73. [PMID: 20483692 DOI: 10.1109/tbme.2010.2046169] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Persons lacking functional auditory nerves cannot benefit from cochlear implants, but an auditory brainstem implant (ABI) utilizing stimulating electrodes adjacent to or on their cochlear nucleus (CN) can restore some hearing. We are investigating the feasibility of supplementing these surface electrodes with penetrating microstimulating electrodes within the ventral CN (VCN), and how the two types of electrodes can be used synergistically. Multiunit neuronal responses evoked by VCN electrical stimulation with surface electrodes and microelectrodes were recorded in the inferior colliculus (ICC) of five cats. The findings are consistent with those from patients with type II neurofibromatosis who received ABIs with both surface and microelectrodes. The patients described percepts from their microelectrodes as more similar to pure tones than those from their surface electrodes, consistent with the greater tonotopic selectivity of microelectrodes in the cats' VCN. Also, the patients describe percepts from their surface electrodes as louder than those from the microelectrodes, while in the cat, the neuronal activity evoked in the ICC by the surface electrodes tended to be greater. This concordance helps to validate our cat model as a means of investigating the synergistic use of surface and penetrating electrodes in a clinical ABI.
Collapse
Affiliation(s)
- Douglas McCreery
- Huntington Medical Research Institutes, Pasadena, CA 91105, USA.
| | | | | |
Collapse
|