1
|
Falconí-Páez C, González-Vaca C, Guarneri J, Fahl N, Aliaga-Sancho P, Mendez-Bauer ML, Galvão Arrais CA, Dávila-Sánchez A. The Impact of Modeling Liquids on Surface Roughness and Color Properties of Bulkfill Resin Composites After Simulated Tooth Brushing: An in Vitro Study. Part I. J ESTHET RESTOR DENT 2024. [PMID: 39295161 DOI: 10.1111/jerd.13314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 07/28/2024] [Accepted: 08/25/2024] [Indexed: 09/21/2024]
Abstract
OBJECTIVE To evaluate the effect of different modeling agents on color changes, surface roughness, and translucency parameters over time in Bulkfill resin composites. MATERIAL AND METHODS Sixty specimens were prepared using three Bulkfill resin composites (Tetric N-Ceram Bulkfill, Filtek One Bulkfill and Opus Bulkfill) and three modeling agents (Wetting Resin, Optibond FL and Ambar APS). All specimens were subjected to a simulated tooth-brushing (Baseline, 50.000 cycles, 100.000 cycles), and surface roughness was measured at each interval. Surface topography was evaluated. The translucency parameter and color changes were assessed after 24-h, 7-, 14- and 30-day immersion in water, wine, and coffee. Data was analyzed using ANOVA and Bonferroni test. RESULTS All specimens increased roughness after simulated tooth-brushing (p < 0.05). Wetting Resin decreased roughness on Tetric N-Ceram Bulkfill (p < 0.05). The translucency parameter remained unaltered for all groups. All groups changed color after 30-days of immersion in wine and coffee (p < 0.05). Ambar APS and Wetting Resin on Tetric N-Ceram Bulkfill showed higher color changes when immersed in coffee (p < 0.05). CONCLUSION The use of modeling agents does not jeopardize translucency properties but may affect surface roughness and color properties of Bulkfill resin composites depending on their composition. CLINICAL SIGNIFICANCE The findings of this study suggest that surface roughness and color properties are affected by the differences in the composition between modeling agents and Bulkfill resins composites.
Collapse
Affiliation(s)
- Camila Falconí-Páez
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Paraná, Brazil
| | - Claudia González-Vaca
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Paraná, Brazil
- Department of Restorative Dentistry and Dental Materials, School of Dentistry, Universidad San Francisco de Quito USFQ, Quito, Ecuador
| | - Juliana Guarneri
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Paraná, Brazil
| | - Newton Fahl
- Private Practice, Curitiba, Brazil
- Clinical and Scientific Director, Fahl Center, Curitiba, Brazil
- University of North Carolina at Chapel Hill, North Carolina, USA
| | - Paulina Aliaga-Sancho
- Department of Restorative Dentistry and Dental Materials, School of Dentistry, Universidad San Francisco de Quito USFQ, Quito, Ecuador
| | - Maria Lujan Mendez-Bauer
- Research Department, School of Dentistry, University Francisco Marroquin, Guatemala City, Guatemala
| | | | - Andrés Dávila-Sánchez
- Department of Restorative Dentistry and Dental Materials, School of Dentistry, Universidad San Francisco de Quito USFQ, Quito, Ecuador
| |
Collapse
|
2
|
Ardelean AI, Marza SM, Negoescu A, Dragomir MF, Sarosi C, Moldovan M, Ene R, Oana L. Assessing Biocompatibility of Composite Cements by Peri/Intramuscular and Subcutaneous Implantation in Rats. Biomedicines 2024; 12:1718. [PMID: 39200185 PMCID: PMC11351888 DOI: 10.3390/biomedicines12081718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/02/2024] [Accepted: 07/31/2024] [Indexed: 09/02/2024] Open
Abstract
This study's goal was to evaluate the biocompatibility of two composite cements over a 90-day period by analyzing the individuals' behavior as well as conducting macroscopic and histological examinations and Computed Tomography (CT) scans. We conducted the cytotoxicity test by placing the materials subcutaneously and peri/intramuscularly. Days 30 and 90 were crucial for our research. On those days, we harvested the implants, kidneys and liver to search for any toxic deposits. The biomaterial's uniformity, color and texture remained unaltered despite being in intimate contact with the tissue. Although a slight inflammatory response was observed in the placement location, we observed an improved outcome of the interaction between the material and its insertion area. There were no notable discoveries in the liver and kidneys. According to the obtained results, the biomaterials did not produce any clinical changes nor specific irritation during the research, demonstrating that they are biocompatible with biological tissues.
Collapse
Affiliation(s)
- Alina Ioana Ardelean
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, University of Agricultura Sciencies and Veterinary Medicine, 400372 Cluj-Napoca, Romania; (A.I.A.); (M.F.D.); (L.O.)
| | - Sorin Marian Marza
- Department of Veterinary Imagistics, Faculty of Veterinary Medicine, University of Agricultura Sciencies and Veterinary Medicine, 400372 Cluj-Napoca, Romania
| | - Andrada Negoescu
- Department of Veterinary Pathology, Faculty of Veterinary Medicine, University of Agricultura Sciencies and Veterinary Medicine, 400372 Cluj-Napoca, Romania;
| | - Madalina Florina Dragomir
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, University of Agricultura Sciencies and Veterinary Medicine, 400372 Cluj-Napoca, Romania; (A.I.A.); (M.F.D.); (L.O.)
| | - Codruta Sarosi
- Department Polymeric Composites, Babeș-Bolyai University, 400294 Cluj-Napoca, Romania; (C.S.); (M.M.)
| | - Marioara Moldovan
- Department Polymeric Composites, Babeș-Bolyai University, 400294 Cluj-Napoca, Romania; (C.S.); (M.M.)
| | - Razvan Ene
- Department Orthopedics, Anesthesia and Intensive Care, University of Medicine and Pharmacy “Carol Davila”, 020021 Bucharest, Romania
- Orthopedics and Traumatology Department, Bucharest Emergency University Hospital, 050098 Bucharest, Romania
| | - Liviu Oana
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, University of Agricultura Sciencies and Veterinary Medicine, 400372 Cluj-Napoca, Romania; (A.I.A.); (M.F.D.); (L.O.)
| |
Collapse
|
3
|
Ajay R, Selvabalaji A, Muthamilselvi M, Vasanthakumari A, Sonia A, Deepa G. Synthesis and Characterization of a Chemico-structurally Modified Bis-GMA Analog for Dental Applications. J Contemp Dent Pract 2024; 25:588-592. [PMID: 39364826 DOI: 10.5005/jp-journals-10024-3687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/05/2024]
Abstract
AIM This study aimed to synthesize and characterize a novel Bis-GMA analog, termed P-Bis-GMA, through structural modification by replacing hydroxyl (-OH) groups with phosphonooxy [-O-P(=O)(OH)2] groups and to evaluate and compare its viscosity with Bis-GMA. MATERIALS AND METHODS Bis-GMA, triethylamine, dichloromethane, and phosphoryl chloride were utilized for the synthesis of P-Bis-GMA through phosphorylation. Fourier discerned the chemical structure of the synthesized P-Bis-GMA transform infrared spectroscopy (FTIR), and its viscosity was assessed by rheometry in oscillatory shear mode over a frequency sweep range of 0.1-100 (ω, rad/s) at 25°C with a 25 mm parallel plate design and a 0.5 mm gap. The data was recorded and statistically analyzed. RESULTS The FTIR analysis confirmed the successful synthesis of P-Bis-GMA, evidenced by the disappearance of hydroxyl (-OH) peaks and the emergence of phosphonooxy [-O-P(=O)(OH)2] peaks in the P-Bis-GMA. Rheological testing demonstrated a notable reduction in viscosity for P-Bis-GMA (436.62 Pa.s) when compared to conventional Bis-GMA (1089.02 Pa.s), indicating improved handling characteristics. CONCLUSION P-Bis-GMA was successfully synthesized by phosphorylation reaction where the -OH groups responsible for the high viscosity in the Bis-GMA were replaced with the [-O-P(=O)(OH)2] groups with significantly reduced viscosity. CLINICAL SIGNIFICANCE The development of P-Bis-GMA holds promise for simplifying dental procedures by reducing chairside time with uncooperative children. The P-Bis-GMA-based composites possess self-adhering properties thereby eschewing the etching and bonding procedures with reduced moisture contamination of the restoration during bonding. This ultimately leads to better clinical outcomes and improved patient experiences by reducing technical vulnerabilities. How to cite this article: Ajay R, Selvabalaji A, Muthamilselvi M, et al. Synthesis and Characterization of a Chemico-structurally Modified Bis-GMA Analog for Dental Applications. J Contemp Dent Pract 2024;25(6):588-592.
Collapse
Affiliation(s)
- Ranganathan Ajay
- Department of Prosthodontics and Crown & Bridge, Vivekanandha Dental College for Women, The Tamil Nadu Dr.M.G.R. Medical University, Namakkal, Tamil Nadu, India
| | - Arumugam Selvabalaji
- Department of Pediatric and Preventive Dentistry, Adhiparasakthi Dental College and Hospital, The Tamil Nadu Dr.M.G.R. Medical University, Melmaruvathur, Tamil Nadu, India, Phone: +91 9003604774, e-mail:
| | - Mathi Muthamilselvi
- Department of Pediatric Dentistry, Institute of Child Health and Research Hospital for Children, Chennai, Tamil Nadu, India
| | - Ananthan Vasanthakumari
- Department of Pediatric and Preventive Dentistry, Adhiparasakthi Dental College and Hospital, The Tamil Nadu Dr.M.G.R. Medical University, Melmaruvathur, Tamil Nadu, India
| | - Abraham Sonia
- Department of Prosthodontics and Crown & Bridge, Adhiparasakthi Dental College and Hospital, The Tamil Nadu Dr.M.G.R. Medical University, Melmaruvathur, Tamil Nadu, India
| | - Gurunathan Deepa
- Department of Pediatric and Preventive Dentistry, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
| |
Collapse
|
4
|
Yu Y, Guo X, Chen J, Zhao Y, Song J, Alshawwa H, Zou X, Zhao H, Zhang Z. Biodegradation of Urethane Dimethacrylate-based materials (CAD/CAM resin-ceramic composites) and its effect on the adhesion and proliferation of Streptococcus mutans. J Mech Behav Biomed Mater 2024; 150:106280. [PMID: 38043260 DOI: 10.1016/j.jmbbm.2023.106280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/24/2023] [Accepted: 11/26/2023] [Indexed: 12/05/2023]
Abstract
OBJECTIVE To investigate whether urethane dimethacrylate (UDMA) -based dental restorative materials biodegrade in the presence of Streptococcus mutans (S. mutans) and whether the monomers affect the adhesion and proliferation of S. mutans in turn. METHODS Cholesterol esterase and pseudocholinesterase-like activities in S. mutans were detected using p-nitrophenyl substrate. Two UDMA-based CAD/CAM resin-ceramic composites, Lava Ultimate (LU) and Vita Enamic (VE), and a light-cured UDMA resin block were co-cultured with S. mutans for 14 days. Their surfaces were characterized by scanning electron microscopy and laser microscopy, and the byproducts of biodegradation were examined by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS). Then, the antimicrobial components (silver nanoparticles with quaternary ammonium salts) were added to the UDMA resin block to detect whether the biodegradation was restrained. Finally, the effect of UDMA on biofilm formation and virulence expression of S. mutans was assessed. RESULTS Following a 14-day immersion, the LU and UDMA resin blocks' surface roughness increased. The LU and VE groups had no UDMA or its byproducts discovered, according to the UPLC-MS/MS data, whereas the light-cured UDMA block group had UDMA, urethane methacrylate (UMA), and urethane detected. The addition of antimicrobial agents showed a significant reduction in the release of UDMA. Biofilm staining experiments showed that UDMA promoted the growth of S. mutans biofilm and quantitative real-time polymerase chain reaction results indicated that 50 μg/mL UDMA significantly increase the expression of gtfB, comC, comD, comE, and gbpB genes within the biofilm. CONCLUSIONS UDMA in the light-cured resin can be biodegraded to produce UMA and urethane under the influence of S. mutans. The formation of early biofilm can be promoted and the expression of cariogenic genes can be up-regulated by UDMA. CLINICAL SIGNIFICANCE This study focuses for the first time on whether UDMA-based materials can undergo biodegradation and verifies from a genetic perspective that UDMA can promote the formation of S. mutans biofilms, providing a reference for the rational use of UDMA-based materials in clinical practice.
Collapse
Affiliation(s)
- Yiyan Yu
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Xinwei Guo
- School of Stomatology, Peking University, Beijing, China
| | - Jiawen Chen
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Yuanhang Zhao
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Jiazhuo Song
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Hamed Alshawwa
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Xinying Zou
- Hospital of Stomatology, Jilin University, Changchun, China; Jilin Provincial Key Laboratory of Oral Biomedical Engineering, China
| | - Hongyan Zhao
- Hospital of Stomatology, Jilin University, Changchun, China.
| | - Zhimin Zhang
- Hospital of Stomatology, Jilin University, Changchun, China.
| |
Collapse
|
5
|
Azlisham NAF, Johari Y, Mohamad D, Yhaya MF, Mahmood Z. Degree of conversion and physicomechanical properties of newly developed flowable composite derived from rice husk using urethane dimethacrylate monomer. Proc Inst Mech Eng H 2023; 237:1339-1347. [PMID: 38014749 DOI: 10.1177/09544119231208222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
This study evaluated the use of urethane dimethacrylate (UDMA) as a base monomer to prepare the newly developed flowable composite (FC) using nanohybrid silica derived from rice husk in comparison to bisphenol A-glycidyl methacrylate (Bis-GMA) on the degree of conversion and physicomechanical properties. The different loadings of base monomer to diluent monomer were used at the ratio of 40:60, 50:50, and 60:40. The bonding analysis confirmed the presence of nanohybrid silica in the newly developed FC. Independent t-test revealed a statistically significant increase in the degree of conversion, depth of cure and Vickers hardness of the UDMA-based FC, while surface roughness showed comparable results between the two base monomers. In conclusion, UDMA-based FC demonstrated superior performance with 60%-65% conversions, a significantly higher depth of cure exceeding 1 mm which complies with the Internal Standard of Organization 4049 (ISO 4049), and a substantial increase in Vickers hardness numbers compared to Bis-GMA-based FC, making UDMA a suitable alternative to Bis-GMA as a base monomer in the formulation of this newly developed FC derived from rice husk.
Collapse
Affiliation(s)
- Nor Ain Fatihah Azlisham
- Unit of Biomaterials, School of Dental Sciences, Universiti Sains Malaysia Health Campus, Kubang Kerian, Kelantan, Malaysia
| | - Yanti Johari
- Unit of Prosthodontics, School of Dental Sciences, Universiti Sains Malaysia Health Campus, Kubang Kerian, Kelantan, Malaysia
| | - Dasmawati Mohamad
- Unit of Biomaterials, School of Dental Sciences, Universiti Sains Malaysia Health Campus, Kubang Kerian, Kelantan, Malaysia
| | - Mohd Firdaus Yhaya
- Unit of Biomaterials, School of Dental Sciences, Universiti Sains Malaysia Health Campus, Kubang Kerian, Kelantan, Malaysia
| | - Zuliani Mahmood
- Unit of Paediatric Dentistry, School of Dental Sciences, Universiti Sains Malaysia Health Campus, Kubang Kerian, Kelantan, Malaysia
| |
Collapse
|
6
|
Zhang S, Wang X, Yang J, Chen H, Jiang X. Micromechanical interlocking structure at the filler/resin interface for dental composites: a review. Int J Oral Sci 2023; 15:21. [PMID: 37258568 DOI: 10.1038/s41368-023-00226-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 06/02/2023] Open
Abstract
Dental resin composites (DRCs) are popular materials for repairing caries or dental defect, requiring excellent properties to cope with the complex oral environment. Filler/resin interface interaction has a significant impact on the physicochemical/biological properties and service life of DRCs. Various chemical and physical modification methods on filler/resin interface have been introduced and studied, and the physical micromechanical interlocking caused by the modification of fillers morphology and structure is a promising method. This paper firstly introduces the composition and development of DRCs, then reviews the chemical and physical modification methods of the filler/resin interface, mainly discusses the interface micromechanical interlocking structures and their enhancement mechanism for DRCs, finally give a summary on the existing problems and development potential.
Collapse
Affiliation(s)
- Shuning Zhang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Xiao Wang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Jiawei Yang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China
| | - Hongyan Chen
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China.
| | - Xinquan Jiang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; Shanghai Engineering Research Center of Advanced Dental Technology and Materials; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, China.
| |
Collapse
|
7
|
Yang ZY, Gao J, Duan LY, Luo ML, Yu F, Xu RC, Zhou MD, Tay FR, Niu LN, Zhou W, Chen JH. Evaluation of a novel primer containing isocyanate group on dentin bonding durability. Dent Mater 2023; 39:455-462. [PMID: 37002165 DOI: 10.1016/j.dental.2023.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 02/05/2023] [Accepted: 03/03/2023] [Indexed: 03/31/2023]
Abstract
OBJECTIVES To evaluate the benefits of a novel dentin-bonding primer, namely, isocyanate-terminated urethane methacrylate precursor (UMP), which can form covalent bonds with demineralized dentin collagen. METHODS The synthesized and purified UMP monomer was characterized and tested its effects on the degree of conversion (DC) and wettability of an acetone-based dental adhesive. Then UMP primers of different concentrations were formulated and used to prepare adhesive specimens, which were compared with solvent-treated groups. Primer-treated specimens with and without aging were also compared. To evaluate the bonding interface, microtensile strength tests, nano-indentation tests and nanoleakage- eavaluation were performed using a field-emission scanning electron microscope and nano-indenter. Data were analyzed using SPSS 20.0 software with significance set at α = 0.05 using one-way analysis of variance (ANOVA) and two-way ANOVA to characterize the effects of the primer. RESULTS Treatment with the UMP primer promoted the DC and wettability of the adhesive on the demineralized dentin surface (P < 0.05); it also increased the bond strength of the aged dentin bonding interface (P < 0.05). Nanoleakage was reduced; the bonding interface became more stable, and the continuity and strength of the hybrid layer improved (P < 0.05) following UMP treatment. The application of 5 mM UMP as a primer for dentin bonding could lead to a stable bonding interface and long-lasting bonding effects. SIGNIFICANCE The use of 5 mM UMP primer developed in this study could improve dentin bonding durability and has excellent clinical application prospects.
Collapse
|
8
|
Isocyanate-free urethane vinyl ester resin: preparation, characterization and thermal and mechanical properties investigation. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02547-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
9
|
Wang Y, Luo S, Zhang X, Wang Z, Qi H, Yan S, Wang X, Wang L, Wu H, Chen Y. Preparation and evaluation of modified
bisphenol‐A
‐glycidyl methacrylate resin dental adhesive to zirconia. POLYM ENG SCI 2022. [DOI: 10.1002/pen.26076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Yuhe Wang
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Shao‐Hua Luo
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Xian Zhang
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Zihan Wang
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Hongfei Qi
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Shengxue Yan
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Xuan Wang
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Luoxuan Wang
- School of Materials Science and Engineering Northeastern University Shenyang China
- Hebei Key Laboratory of Dielectric and Electrolyte Functional Material, School of Resources and Materials Northeastern University at Qinhuangdao Qinhuangdao China
| | - Haiyan Wu
- Research and Development Department Aidite (Qinhuangdao) Technology Co., Ltd. Qinhuangdao China
| | - Yingying Chen
- Research and Development Department Aidite (Qinhuangdao) Technology Co., Ltd. Qinhuangdao China
| |
Collapse
|
10
|
Ghasemi S, Ghezelsofloo M, Naeimi M, Tamami B, Allahyari H. Isocyanate‐free urethane modified vinyl ester resin: synthesis, characterization, and mechanical properties. POLYM INT 2022. [DOI: 10.1002/pi.6432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Soheila Ghasemi
- Chemistry Department, College of Science Shiraz University 7194684795 Shiraz Iran
| | - Milad Ghezelsofloo
- Chemistry Department, College of Science Shiraz University 7194684795 Shiraz Iran
| | - Mahsa Naeimi
- Chemistry Department, College of Science Shiraz University 7194684795 Shiraz Iran
| | - Bahman Tamami
- Chemistry Department, College of Science Shiraz University 7194684795 Shiraz Iran
| | - Hamed Allahyari
- Chemistry Department, College of Science Shiraz University 7194684795 Shiraz Iran
| |
Collapse
|
11
|
Photopolymerizable dental composite resins with lower shrinkage stress and improved hydrolytic and hygroscopic behavior with a urethane monomer used as an additive. J Mech Behav Biomed Mater 2022; 130:105189. [DOI: 10.1016/j.jmbbm.2022.105189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 03/14/2022] [Accepted: 03/18/2022] [Indexed: 11/15/2022]
|
12
|
Harp YS, Montaser MA, Zaghloul NM. Flowable fiber-reinforced versus flowable bulk-fill resin composites: Degree of conversion and microtensile bond strength to dentin in high C-factor cavities. J ESTHET RESTOR DENT 2022; 34:699-706. [PMID: 35274436 DOI: 10.1111/jerd.12901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 02/28/2022] [Accepted: 03/01/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To compare flowable fiber-reinforced and flowable bulk-fill resin composites regarding their degree of conversion (DC) and microtensile bond strength (μTBS) to dentin in high C-factor class I cavities. MATERIALS AND METHODS One flowable fiber-reinforced (EverX Flow, GC) and two flowable bulk-fill composites (SDR, Dentsply, and Tetric N-flow Bulk fill, Ivoclar Vivadent) were tested. Regarding DC, 10 cylindrical-shaped specimens were prepared from each material (N = 30), measured using Fourier-Transform Infrared Spectroscopy (FTIR). Regarding µ TBS , class I cavities (4.5 × 4.5 × 3) were prepared on flat dentin surfaces of 30 molars, divided into three equal groups, restored with the three restorative materials, thermocycled, sectioned to create 1 mm × 1 mm cross-sectional beams, then tested using a universal testing machine. Failure mode was assessed using a stereomicroscope. Two-way ANOVA and Tukey's HSD post-hoc tests were used in DC, while One-way ANOVA was used for µ TBS . RESULTS The used materials showed statistically significant differences in DC with the fiber-reinforced composite having the highest value. No statistically significant differences were found between the materials regarding their µ TBS . CONCLUSIONS Flowable fiber-reinforced composite provided the most DC performance compared to the flowable bulk-fill composites. The three used restorative materials provided comparable bonding ability to dentin in high C-factor cavities. CLINICAL SIGNIFICANCE Flowable fiber-reinforced resin composite is preferred as a dentin-replacement material in high-stress bearing areas. However, both flowable fiber-reinforced and bulk-fill resin composites are equally effective in bonding to dentin in high C-factor cavities.
Collapse
Affiliation(s)
- Youniss Saleh Harp
- Department of Operative Dentistry, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Marmar Ahmed Montaser
- Department of Operative Dentistry, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Nadia Mohamed Zaghloul
- Department of Operative Dentistry, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
13
|
Kincses D, Böddi K, Őri Z, Lovász BV, Jeges S, Szalma J, Kunsági-Máté S, Lempel E. Pre-Heating Effect on Monomer Elution and Degree of Conversion of Contemporary and Thermoviscous Bulk-Fill Resin-Based Dental Composites. Polymers (Basel) 2021; 13:polym13203599. [PMID: 34685358 PMCID: PMC8538921 DOI: 10.3390/polym13203599] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 10/12/2021] [Accepted: 10/13/2021] [Indexed: 11/16/2022] Open
Abstract
Detection of unreacted monomers from pre-heated resin-based dental composites (RBC) is not a well-investigated topic so far. The objectives were to determine the temperature changes during the application and polymerization, the degree of conversion (DC) and unreacted monomer elution of room temperature (RT), and pre-heated thermoviscous [VisCalor Bulk(VCB)] and high-viscosity full-body contemporary [Filtek One Bulk(FOB)] bulk-fill RBCs. The RBCs' temperatures during the sample preparation were recorded with a K-type thermocouple. The DC at the top and bottom was measured with micro-Raman spectroscopy and the amounts of eluted BisGMA, UDMA, DDMA, and TEGDMA were assessed with High-Performance Liquid Chromatography. The temperatures of the pre-heated RBCs decreased rapidly during the manipulation phase. The temperature rise during photopolymerization reflects the bottom DCs. The differences in DC% between the top and the bottom were significant. RT VCB had a lower DC% compared to FOB. Pre-heating did not influence the DC, except on the bottom surface of FOB where a significant decrease was measured. Pre-heating significantly decreased the elution of BisGMA, UDMA, DDMA in the case of FOB, meanwhile, it had no effect on monomer release from VCB, except TEGDMA, which elution was decreased. In comparison, RBC composition had a stronger influence on DC and monomer elution, than pre-cure temperature.
Collapse
Affiliation(s)
- Dóra Kincses
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary;
| | - Katalin Böddi
- Department of Biochemistry and Medical Chemistry, University of Pécs Medical School, Szigeti Street 12, 7624 Pécs, Hungary;
| | - Zsuzsanna Őri
- Department of Physical Chemistry and Materials Science, University of Pécs, Ifjúság Street 6, 7624 Pécs, Hungary;
- János Szentágothai Research Center, Ifjúság Street 20, 7624 Pécs, Hungary;
| | - Bálint Viktor Lovász
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary; (B.V.L.); (J.S.)
| | - Sára Jeges
- Faculty of Sciences, University of Pécs, Ifjúság Street 12, 7624 Pécs, Hungary;
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary; (B.V.L.); (J.S.)
| | - Sándor Kunsági-Máté
- János Szentágothai Research Center, Ifjúság Street 20, 7624 Pécs, Hungary;
- Institute of Organic and Medicinal Chemistry, Faculty of Pharmacy, University of Pécs Medical School, Szigeti Street 12, 7624 Pécs, Hungary
| | - Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary;
- Correspondence: ; Tel.: +36-72-535-926
| |
Collapse
|
14
|
Boonen I, De Nys S, Vervliet P, Covaci A, Van Landuyt KL, Duca RC, Godderis L, Denison MS, Elskens M. Assessing the estrogenic activity of chemicals present in resin based dental composites and in leachates of commercially available composites using the ERα-CALUX bioassay. Dent Mater 2021; 37:1834-1844. [PMID: 34579959 DOI: 10.1016/j.dental.2021.09.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 09/01/2021] [Accepted: 09/13/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The biocompatibility of resin based dental composites has not yet been fully characterized even though certain monomers used in these composites are synthesized from Bisphenol A (BPA), a well-known estrogenic endocrine disruptor. As a result, they show structural relationship to BPA and can contain it as an impurity. Therefore, the estrogenic activity of 9 monomers, 2 photoinitiators, one photostabilizer and leachates of 4 commercially available composites was determined. METHODS The ERα-CALUX bioassay was used to determine both agonistic and antagonistic estrogenic activities of the pure compounds (BPA, BisDMA, BisGMA, BisEMA(3), BisEMA(6), BisEMA(10), TEGDMA, TCD-DI-HEA, BADGE, UDMA, HMBP, DMPA, CQ) and the leachates of cured composite disks. The leachates of 4 commercially available composites (Solitaire 2, Ceram.x Spectra ST, G-ænial Posterior and Filtek Supreme XTE) in water and 0.1 M NaOH (pH = 13, 'worst-case scenario') were tested for estrogenic activity (pooled leachates from 10 cured composite disks). RESULTS Agonistic estrogenic activity was found for the monomer BisDMA, the photostabilizer HMBP and photoinitiator DMPA. All leachates from the 4 tested composites showed significant agonistic estrogenic activity higher than the DMSO control, and the highest activity (potency and efficacy) was found for Solitaire 2, followed by Ceram.x Spectra ST. Furthermore, antagonistic estrogenic activity was found in the leachates from G-ænial Posterior. SIGNIFICANCE These results show that significant estrogenic activity was found in all leachates of the cured composite disks, and that this estrogenicity is most likely due to a mixture effect of multiple estrogenic compounds (including BPA, HMBP and DMPA). This indicates that further research into the endocrine activity of all the compounds that are present in these composites (even at low quantities) and their possible mixture effect is warranted to guarantee their safe use.
Collapse
Affiliation(s)
- Imke Boonen
- Vrije Universiteit Brussel, Department of Analytical, Environmental and Geo-Chemistry, Brussels, 1050, Belgium.
| | - Siemon De Nys
- KU Leuven (University of Leuven), Department of Oral Health Sciences, Leuven, 3000, Belgium
| | | | - Adrian Covaci
- University of Antwerp, Toxicological Centre, Antwerp, 2000, Belgium
| | - Kirsten L Van Landuyt
- KU Leuven (University of Leuven), Department of Oral Health Sciences, Leuven, 3000, Belgium
| | - Radu Corneliu Duca
- KU Leuven (University of Leuven), Department of Public Health and Primary Care, Environment and Health, Leuven, 3000, Belgium; National Health Laboratory (LNS), Department of Health Protection, Environmental Hygiene and Human Biological Monitoring, Dudelange, L-3555, Luxembourg
| | - Lode Godderis
- KU Leuven (University of Leuven), Department of Public Health and Primary Care, Environment and Health, Leuven, 3000, Belgium; IDEWE, External Service for Prevention and Protection at Work, Interleuvenlaan 58, 3001, Heverlee, Belgium
| | - Michael S Denison
- University of California at Davis, Department of Environmental Toxicology, Davis, 95616, USA
| | - Marc Elskens
- Vrije Universiteit Brussel, Department of Analytical, Environmental and Geo-Chemistry, Brussels, 1050, Belgium
| |
Collapse
|
15
|
Khan AS, AlMaimouni YK, Benrashed MA, Alyousef NI, Siddiqui U, Ahmad N, Ateeq IS, Hakeem AS. A laboratory study to assess the physical, mechanical, and 3-D structural properties of nano-apatite grafted glass fibre-based endodontic posts. Int Endod J 2021; 54:2307-2320. [PMID: 34496045 DOI: 10.1111/iej.13630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 09/04/2021] [Accepted: 09/07/2021] [Indexed: 02/06/2023]
Abstract
AIM To fabricate and characterize nano-hydroxyapatite (nHA) grafted and non-grafted glass fibre-based endodontic posts. METHODOLOGY Experimental glass fibre posts were fabricated using silanized nHA grafted (ex-HA) and non-grafted glass fibre (ex-P) reinforced resins. The structural analysis and morphological patterns were analysed with Fourier transform infrared spectroscopy and scanning electron microscopy, respectively. EverStick® glass fibre posts (eS) were used as a control group. The degree of conversion, flexural strength, and flexural modulus was investigated and the fractured structure was evaluated with a scanning electron microscope. Root canals were prepared in human extracted teeth restored with experimental and control posts. The push-out bond strength was evaluated with radicular dentine at days 7, 30, and 90, and the presence of voids at the interface were measured at day 1, 7, 30, and 90 with micro-computed tomography. The Shapiro-Wilk test and one-way ANOVA post-hoc Tukey's test were performed. The level of significance was set at 0.05. RESULTS The SEM and FTIR confirmed the presence of a silane-coupling agent on the glass fibres. The ex-HA post had a significantly lower degree of conversion compared to the ex-P post (p = .0008), but a significantly higher conversion than the eS post (p = .0014). The maximum flexural strength value was obtained with the ex-HA post with an insignificant difference (p = .366) compared to ex-P post and a significant difference (p = .029) compared to the eS post. The flexural modulus of ex-HA, ex-P, and eS posts were significantly different (p = .037). Similarly, the ex-HA post had a significantly higher push-out bond strength at days 7 and 30 (p = .037) compared to the ex-P and eS posts. The volume of voids had a nonlinear behaviour amongst the groups with no significant difference between the posts. CONCLUSION The fabrication of the experimental posts was successful and the ex-HA post had greater flexural strength and push-out bond strength compared to the ex-P post. The degree of conversion of the ex-HA post was lower than the ex-P and eS posts. The volume of voids of ex-HA and ex-P posts was lower than that of eS posts.
Collapse
Affiliation(s)
- Abdul S Khan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Yara K AlMaimouni
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mashael A Benrashed
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nujood I Alyousef
- Dental Department, Marat General Hospital, Ministry of Health, Riyadh, Saudi Arabia
| | - Usama Siddiqui
- Interdisciplinary Research Centre in Biomedical Materials, COMSATS University Islamabad, Lahore Campus, Lahore, Pakistan.,Department of Dental Materials, Rehman College of Dentistry, Peshawar, Pakistan
| | - Niyaz Ahmad
- Department of Pharmaceutics, College of Clinical Pharmacy, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal S Ateeq
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Abbas S Hakeem
- Interdisciplinary Research Center for Hydrogen & Energy Storage (IRC-HES), King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| |
Collapse
|
16
|
Wang X, Gao G, Song HB, Zhang X, Stansbury JW, Bowman CN. Evaluation of a photo-initiated copper(I)-catalyzed azide-alkyne cycloaddition polymer network with improved water stability and high mechanical performance as an ester-free dental restorative. Dent Mater 2021; 37:1592-1600. [PMID: 34456051 DOI: 10.1016/j.dental.2021.08.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 08/14/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The objective is to develop and characterize an ester-free ether-based photo-CuAAC resin with high mechanical performance, low polymerization-induced stress compared with common BisGMA/TEGDMA (70/30) resins, and improved water stability in comparison to previously developed urethane-based photo-CuAAC resins. METHODS Triphenyl-ethane-centered ether-linked tri-azide monomers were synthesized and co-photopolymerized with ether-linked tri-alkyne monomers under visible light irradiation using a copper(II) pre-catalyst and CQ/EDAB as the initiator. The ether-based CuAAC formulation was investigated for thermo-mechanical properties, polymerization kinetics and shrinkage stress, and flexural properties with respect to a conventional BisGMA/TEGDMA (70/30) dental resin. In addition, both the ether-based CuAAC resin and the urethane-based CuAAC resin were examined for their water stability using the BisGMA/TEGDMA (70/30) resin as a control. RESULTS The ether-based CuAAC network (AK/AZ-1) exhibited a slightly lower glass-transition temperature compared with the BisGMA/TEGDMA network (108 °C vs 128 °C), but because of its much sharper glass transition, the AK/AZ-1 CuAAC-network maintained storage modulus higher than 1 GPa up to 100 °C. In addition, the ether-based AK/AZ-1 network exhibited reduced shrinkage stress (0.56 MPa vs 1.0 MPa) and much higher flexural toughness (7.6 MJ/m3vs 1.6 MJ/m3) while showing slightly lower flexural modulus and slightly higher flexural strength compared with the BisGMA/TEGDMA network. Moreover, the ether-based AK/AZ-1 CuAAC network displayed comparable water stability in comparison to the BisGMA/TEGDMA network with slightly higher water sorption (46 μg/mm3vs 38 μg/mm3) and much lower water solubility (2.3 μg/mm3vs 4.4 μg/mm3). SIGNIFICANCE Employing the ether-based hydrophobic CuAAC formulation significantly improved the water stability of the CuAAC network compared with previously developed urethane-based CuAAC networks. Furthermore, compared with the conventionally used BisGMA/TEGDMA formulation, the reduced shrinkage stress, comparable flexural strength/flexural modulus, and the superior flexural toughness of the ether-based CuAAC network make it a promising ester-free alternative to the currently widely-used methacrylate-based dental restoratives.
Collapse
Affiliation(s)
- Xiance Wang
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Guangzhe Gao
- Materials Science and Engineering Program, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Han Byul Song
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Xinpeng Zhang
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Jeffrey W Stansbury
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States; Department of Craniofacial Biology, School of Dental Medicine, Anschutz Medical Campus, Aurora, CO, United States
| | - Christopher N Bowman
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States; Materials Science and Engineering Program, University of Colorado Boulder, 596 UCB, Boulder, CO, United States.
| |
Collapse
|
17
|
Almohareb T, Alayed AA, Alzahrani KM, Maawadh AM, Almutairi B, Alhamdan RS, Bahkali A, Abduljabbar T, Vohra F. Influence of curing duration and mixing techniques of bulk fill resin composites on bi-axial flexural strength and degree of conversion. J Appl Biomater Funct Mater 2020; 18:2280800020975721. [PMID: 33326308 DOI: 10.1177/2280800020975721] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVES The aim was to assess the influence of polymerization duration, method and resin manipulation techniques on the biaxial flexural strength (BFS) and degree of conversion (DC) of bulk fill resin composites (BFRC). METHODS One hundred and eighty disc specimens were fabricated using MultiCore (MC) and Core-It (CI) bulk fill resin composite. Each material group, specimens were divided into nine subgroups based on curing methods (Light cure for 10 and 20 s; and auto-cure) and mixing techniques (first auto-mix, second automix, and hand mix). BFS was tested with a ball indenter at a crosshead speed of 0.50 mm/min. DC was assessed for MC and CI materials for 10 s and 20 s light cure; and auto cure specimens using Fourier Transform-Infrared Spectroscopy (FTIR). Statistical data comparisons were performed using ANOVA, Bonferroni and Tukey-Kramer tests. RESULTS For MC and CI, BFS was highest in 10 s light cure specimens, however comparable to specimens cured for 20 s (p > 0.05). Auto cure specimens showed lower BFS than light cured samples for both materials (p < 0.05). Hand mixed specimens showed significantly compromised BFS compared to automix technique for MC and CI. DC % was comparable for 10 s and 20 s light cure methods for both materials (p > 0.05), which was higher than DC % of auto cure bulk fill resins (p < 0.05). CI showed higher DC % and BFS compared to MC bulk fill resin composite. CONCLUSION Photo-polymerization duration of 10 and 20 s showed similar outcomes for BFS and DC %; and BFS for auto-mixed resins (MC and CI) was significantly higher than hand mixed resin. BFS and DC was higher in photopolymerized groups as compared to auto-cured resin regardless of the manipulation technique for both materials (MultiCore and Core it).
Collapse
Affiliation(s)
- Thamer Almohareb
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Abdulaziz A Alayed
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Khalid M Alzahrani
- Department of Prosthetic Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, 11942 Alkharj, Saudi Arabia
| | - Ahmed M Maawadh
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Basil Almutairi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Rana S Alhamdan
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Ahlam Bahkali
- General Dentist and QPS Chair, Dental Service-Westren Region, King Abdulaziz Medical City-Jeddah-Ministry of National Guard, Jeddah, Makkah, Saudi Arabia
| | - Tariq Abduljabbar
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University; Research Chair for Biological Research in Dental Health, College of Dentistry, Riyadh, Saudi Arabia
| | - Fahim Vohra
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University; Research Chair for Biological Research in Dental Health, College of Dentistry, Riyadh, Saudi Arabia
| |
Collapse
|
18
|
Bin Nooh AN, Nahedh HA, AlRefeai M, Alkhudhairy F. The Effect of Irradiance on the Degree of Conversion and Volumetric Polymerization Shrinkage of Different Bulk-Fill Resin-Based Composites: An In Vitro Study. Eur J Dent 2020; 15:312-319. [PMID: 33321544 PMCID: PMC8184305 DOI: 10.1055/s-0040-1721236] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Objective
The influence of different light-emitting diode (LED) curing light intensities on the degree of conversion (DC) and volumetric polymerization shrinkage (VPS) of bulk-fill resin-based composite (RBC) restorative materials was evaluated.
Materials and Methods
Twenty-four specimens of each RBC material (Filtek one bulk-fill posterior, Reveal HD Bulk, Tetric N-Ceram, and Filtek Z350) were prepared. The RBCs were shaped in molds and cured using an LED curing light unit at high-intensity (1,200 mW/cm
2
) for 20 seconds and low-intensity (650 mW/cm
2
) for 40 seconds Fourier-transform infrared (FTIR) spectroscopy was used to determine the DC and microcomputed tomography was used to evaluate VPS. Data were analyzed using one- and two-way ANOVA, independent
t
-test, and Tukey’s and Scheffe’s post hoc multiple comparison tests.
Results
With high-intensity curing light, Reveal HD showed the highest DC (85.689 ± 6.811%) and Tetric N-Ceram the lowest (52.60 ± 9.38%). There was no statistical difference in VPS when using high- or low-intensity curing light. The highest VPS was observed for Reveal HD (2.834–3.193%); there was no statistical difference (
p
> 0.05) among the other RBCs.
Conclusion
Curing light intensities do not significantly influence the VPS of RBC materials. Reveal HD bulk cured with high-intensity light had the highest DC.
Collapse
Affiliation(s)
- Abrar N Bin Nooh
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Hend Al Nahedh
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Mohammad AlRefeai
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Fahad Alkhudhairy
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| |
Collapse
|
19
|
Fugolin AP, de Paula AB, Dobson A, Huynh V, Consani R, Ferracane JL, Pfeifer CS. Alternative monomer for BisGMA-free resin composites formulations. Dent Mater 2020; 36:884-892. [PMID: 32402514 PMCID: PMC7305961 DOI: 10.1016/j.dental.2020.04.009] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 01/24/2020] [Accepted: 04/20/2020] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Water sorption, high volumetric shrinkage, polymerization stress, and potential estrogenic effects triggered by leached compounds are some of the major concerns related to BisGMA-TEGDMA co-monomer systems used in dental composites. These deficiencies call for the development of alternative organic matrices in order to maximize the clinical lifespan of resin composite dental restorations. This study proposes BisGMA-free systems based on the combination of UDMA and a newly synthesized diurethane dimethacrylate, and evaluates key mechanical and physical properties of the resulting materials. METHODS 2EMATE-BDI (2-hydroxy-1-ethyl methacrylate) was synthesized by the reaction between 2-hydroxy-1-ethyl methacrylate with a difunctional isocyanate (1.3-bis (1- isocyanato-1-methylethylbenzene) - BDI). The compound was copolymerized with UDMA (urethane dimethacrylate) at 40 and 60wt%. UDMA copolymerizations with 40 and 60wt% TEGDMA (triethylene glycol dimethacrylate) were tested as controls, as well as a formulation based in BisGMA (bisphenol A-glycidyl methacrylate)-TEGDMA 60:40% (BT). The organic matrices were made polymerizable by the addition of DMPA (2.2-dimethoxyphenoxy acetophenone) and DPI-PF6 (diphenyliodonium hexafluorophosphate) at 0.2 and 0.4wt%, respectively. Formulations were tested as composite with the addition of 70wt% inorganic content consisting of barium borosilicate glass (0.7μm) and fumed silica mixed in 95 and 5wt%, respectively. All photocuring procedures were carried out by a mercury arc lamp filtered to 320-500nm at 800mW/cm2. The experimental resin composites were tested for kinetics of polymerization and polymerization stress in real time. Flexural strength, elastic modulus, water sorption, and solubility were assessed according to ISO 4049. Biofilm formation was analyzed after 24h by luciferase assay. Data were statistically analyzed by one-way ANOVA and Tukey's test (α≤0.05). RESULTS In general, the addition of 2EMATE-BDI into the formulations decreased the maximum rate of polymerization (RPMAX), the degree of conversion at RPMAX (DC at RPMAX), and the final degree of conversion (final DC). However, these reductions did not compromise mechanical properties, which were comparable to the BT controls, especially after 7-day water incubation. The incorporation of 60wt% 2EMATE-BDI reduced water sorption of the composite. 2EMATE-BDI containing formulations showed reduction in polymerization stress of 30% and 50% in comparison to BT control and TEGDMA copolymerizations, respectively. Biofilm formation was similar among the tested groups. SIGNIFICANCE The use of the newly synthesized diurethane dimethacrylate as co-monomer in dental resin composite formulations seems to be a promising option to develop polymers with low-shrinkage and potentially decreased water degradation.
Collapse
Affiliation(s)
- Ana P Fugolin
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States
| | - Andreia B de Paula
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States
| | - Adam Dobson
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States
| | - Vincent Huynh
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States
| | - Rafael Consani
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States
| | - Jack L Ferracane
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States
| | - Carmem S Pfeifer
- Department of Restorative Dentistry/Division of Biomaterials and Biomechanics, 2730 SW Moody Avenue, Portland, OR 97201, United States.
| |
Collapse
|
20
|
Sinha J, Dobson A, Bankhar O, Podgórski M, Shah PK, Zajdowicz SLW, Alotaibi A, Stansbury JW, Bowman CN. Vinyl sulfonamide based thermosetting composites via thiol-Michael polymerization. Dent Mater 2020; 36:249-256. [PMID: 31791733 PMCID: PMC7012731 DOI: 10.1016/j.dental.2019.11.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2019] [Accepted: 11/15/2019] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To assess the performance of thiol Michael photocurable composites based on ester-free thiols and vinyl sulfonamides of varying monomer structures and varied filler loadings and to contrast the properties of the prototype composites with conventional BisGMA-TEGDMA methacrylate composite. METHODS Synthetic divinyl sulfonamides and ester-free tetrafunctional thiol monomers were utilized for thiol-Michael composite development with the incorporation of thiolated microfiller. Polymerization kinetics was investigated using FTIR spectroscopy. Resin viscosities were assessed with rheometry. Water uptake properties were assessed according to standardized methods. Thermomechanical properties were analyzed by dynamic mechanical analysis. Flexural modulus/strength and flexural toughness were measured on a universal testing machine in three-point bending testing mode. RESULTS The vinyl sulfonamide-based thiol-Michael resin formulation demonstrated a wide range of viscosities with a significant increase in the functional group conversion when compared to the BisGMA-TEGDMA system. The two different types of vinyl sulfonamide under investigation demonstrated significant differences towards the water sorption. Tertiary vinyl sulfonamide did not undergo visible swelling whereas the secondary vinyl sulfonamide composite swelled extensively in water. With the introduction of rigid monomer into the polymer matrix the glass transition temperature increased and so increased the toughness. Glassy thiol-Michael composites were obtained by ambient curing. SIGNIFICANCE Employing the newly developed step-growth thiol-Michael resins in dental composites will provide structural uniformity, improved stability and lower water sorption.
Collapse
Affiliation(s)
- Jasmine Sinha
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States
| | - Adam Dobson
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States
| | - Osamah Bankhar
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States
| | - Maciej Podgórski
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States; Department of Polymer Chemistry, Faculty of Chemistry, Maria Curie-Sklodowska University, Gliniana St. 33, Lublin 20-614, Poland
| | - Parag K Shah
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States
| | - Sheryl L W Zajdowicz
- Department of Biology, Metropolitan State University of Denver, PO Box 173362, Campus Box #53, Denver, CO 80217, United States
| | - Abdulaziz Alotaibi
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States
| | - Jeffrey W Stansbury
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States; Department of Craniofacial Biology, School of Dental Medicine, Anschutz Medical Campus, Aurora, CO, United States
| | - Christopher N Bowman
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, United States.
| |
Collapse
|
21
|
Li KY, Tsai CC, Lin TC, Wang YL, Lin FH, Lin CP. Fluorinated Montmorillonite and 3YSZ as the Inorganic Fillers in Fluoride-Releasing and Rechargeable Dental Composition Resin. Polymers (Basel) 2020; 12:polym12010223. [PMID: 31963243 PMCID: PMC7023564 DOI: 10.3390/polym12010223] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 01/11/2020] [Accepted: 01/13/2020] [Indexed: 12/29/2022] Open
Abstract
Dental caries (tooth decay) is the most frequent oral disease in humans. Filling cavities with a dental restorative material is the most common treatment, and glass ionomer cements are the main fluoride ion release restorative materials. The goal of this study was to develop a restorative compound with superior fluoride ion release and recharge abilities. Previously developed fluorinated bentolite and hydrophobized 3YSZ were used as two different inorganic fillers mixed in a bisphenol A-glycidyl methacrylate (Bis-GMA) matrix. XRD, FTIR, and TGA were used to determine the hydrophobic modification of these two inorganic fillers. In mechanical tests, including diameter tensile strength, flexural strength, and wear resistance, the developed composite resin was significantly superior to the commercial control. A WST-1 assay was used to confirm that the material displayed good biocompatibility. Furthermore, the simulation of the oral environment confirmed that the composite resin had good fluoride ion release and reloading abilities. Thus, the composite resin developed in this study may reduce secondary caries and provide a new choice for future clinical treatments.
Collapse
Affiliation(s)
- Keng-Yuan Li
- Institute of Biomedical Engineering, National Taiwan University, No.49, Fanglan Rd., Da’an Dist., Taipei 10672, Taiwan; (K.-Y.L.); (T.-C.L.)
| | - Cheng-Chia Tsai
- Department of Neurosurgery, Mackay Memorial Hospital, No.92, Sec. 2, Zhongshan N. Rd., Zhongshan Dist., Taipei 10449, Taiwan;
| | - Tzu-Chieh Lin
- Institute of Biomedical Engineering, National Taiwan University, No.49, Fanglan Rd., Da’an Dist., Taipei 10672, Taiwan; (K.-Y.L.); (T.-C.L.)
| | - Yin-Lin Wang
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, No.1, Sec. 1, Ren’ai Rd., Zhongzheng Dist., Taipei 10051, Taiwan;
- National Taiwan University Hospital, College of Medicine, National Taiwan University, No.1, Changde St., Zhongzheng Dist., Taipei 10048, Taiwan
| | - Feng-Huei Lin
- Institute of Biomedical Engineering, National Taiwan University, No.49, Fanglan Rd., Da’an Dist., Taipei 10672, Taiwan; (K.-Y.L.); (T.-C.L.)
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, No.35, Keyan Rd., Zhunan Township, Miaoli County 35053, Taiwan
- Correspondence: (F.-H.L.); (C.-P.L.); Tel.: +886-2-2732-0443 (F.-H.L.); +886-2-2312-3456 (C.-P.L.)
| | - Chun-Pin Lin
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, No.1, Sec. 1, Ren’ai Rd., Zhongzheng Dist., Taipei 10051, Taiwan;
- National Taiwan University Hospital, College of Medicine, National Taiwan University, No.1, Changde St., Zhongzheng Dist., Taipei 10048, Taiwan
- Correspondence: (F.-H.L.); (C.-P.L.); Tel.: +886-2-2732-0443 (F.-H.L.); +886-2-2312-3456 (C.-P.L.)
| |
Collapse
|
22
|
Barreto Girão L, Ohana de Lima Martins J, Lemos JVM, Pinto MR, Rolim JPML, Alves E Silva FCF, Saboia VDPA, Bitu Sousa F, de Barros Silva PG. Influence of the degree of conversion and Bis-GMA residues of bulk fill resins on tissue toxicity in an subcutaneous model in rats. J Appl Biomater Funct Mater 2020; 18:2280800020947330. [PMID: 33151768 DOI: 10.1177/2280800020947330] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
AIM To analyse the influence of the degree of conversion (DC) and light curing residues of different bulk fills (BFs) composites on the inflammatory profile in the subcutaneous tissue of rats. MATERIALS AND METHODS Resin disks of BF-resins and their active conventional resins (CR; 3M®, Ivoclar®, and Kerr®) were light-cured at 2 mm (BF-superficial) and 4 mm (BF-deep) thicknesses and analyzed by infrared spectroscopy (FTIR; n = 3/group; DC and light curing residues). Then, the disks were implanted in four quadrants in the subcutaneous tissue of Wistar rats (sham, CR, BF-superficial and RF-deep), and after 7, 14, and 28 days, the animals (n = 6/day) were euthanized for histological analysis of the intensity of the inflammatory process (scores 0-3). Kruskal-Wallis/Dunn and ANOVA/Bonferroni tests were used (p < 0.05, Graph Pad Prism 5.0). RESULTS The DC of CR 3M® did not differ significantly compared to BF-superficial and BF-deep resins (p = 0.235). The Ivoclar® and Kerr® resins showed a higher DC with CR and BF-superficial compared to the BF-deep (p = 0.005 and p = 0.011, rctively). Kerr® resins showed a higher Bis-GMA/UDMA ratio, especially in BF-deep resin (p < 0.05). 3M® and Ivoclar resins did not show high inflammation scores, but for Kerr® BF resins (superficial and deep), the inflammatory process was significantly higher than that in the CR and sham quadrants (p = 0.031). CONCLUSION The tissue inflammatory response after resin inoculation depends on the DC and light curing residues of Bis-GMA.
Collapse
Affiliation(s)
| | - Joyce Ohana de Lima Martins
- Department of Dentistry, Unichristus, Fortaleza, Ceará, Brazil.,Department of Clinic Dentistry, Federal University of Ceará, Fortaleza, Ceará, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Rezaei S, Abbasi M, Sadeghi Mahounak F, Moradi Z. Curing Depth and Degree of Conversion of Five Bulk-Fill Composite Resins Compared to a Conventional Composite. Open Dent J 2019. [DOI: 10.2174/1874210601913010422] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background:
Limited curing depth and its effect on the degree of conversion are among the challenges of working with light-cure composite resins. The use of bulk-fill composites is one strategy to overcome these limitations.
Methods:
Ever X Posterior (EXP), Filtek Bulk-Fill Posterior (FBP), Sonic Fill 2 (SF2), Tetric N-Ceram Bulk-Fill (TNB), and X-tra Fil (XF) bulk-fill and Filtek Z250 conventional composite were evaluated in this in vitro experimental study. Six samples for the assessment of microhardness and three samples for the evaluation of DC were fabricated of each composite. After light curing and polishing, the samples were incubated at 37°C for 24 hours. Microhardness was measured by a Vickers hardness tester three times and the mean value was calculated. DC of the top and bottom surfaces was determined using Fourier-Transform Infrared Spectroscopy (FTIR). Data were analyzed using one-way ANOVA and Tukey’s test.
Results:
Microhardness and DC were significantly different among the groups (P<0.001). XF and Z250 equally showed the highest bottom-to-top surface microhardness ratio (0.97 ± 0.01) and significantly higher DC in the top (P<0.001) and bottom (P<0.005) surfaces compared to other groups. TNB showed the lowest microhardness ratio (0.88 ± 0.04) and DC (68.66 ± 1.52 and 61.00 ± 2.00); the difference in DC of the bottom surface was statistically significant (P<0.003).
Conclusion:
It appears that bulk-fill composites evaluated in this study are adequately polymerized at 4 mm depth. Their DC was optimal and within the range of conventional composites.
Collapse
|
24
|
Barszczewska-Rybarek IM. A Guide through the Dental Dimethacrylate Polymer Network Structural Characterization and Interpretation of Physico-Mechanical Properties. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E4057. [PMID: 31817410 PMCID: PMC6947234 DOI: 10.3390/ma12244057] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Revised: 11/26/2019] [Accepted: 11/28/2019] [Indexed: 12/15/2022]
Abstract
Material characterization by the determination of relationships between structure and properties at different scales is essential for contemporary material engineering. This review article provides a summary of such studies on dimethacrylate polymer networks. These polymers serve as photocuring organic matrices in the composite dental restorative materials. The polymer network structure was discussed from the perspective of the following three aspects: the chemical structure, molecular structure (characterized by the degree of conversion and crosslink density (chemical as well as physical)), and supramolecular structure (characterized by the microgel agglomerate dimensions). Instrumental techniques and methodologies currently used for the determination of particular structural parameters were summarized. The influence of those parameters as well as the role of hydrogen bonding on basic mechanical properties of dimethacrylate polymer networks were finally demonstrated. Mechanical strength, modulus of elasticity, hardness, and impact resistance were discussed. The issue of the relationship between chemical structure and water sorption was also addressed.
Collapse
|
25
|
Pratap B, Gupta RK, Bhardwaj B, Nag M. Resin based restorative dental materials: characteristics and future perspectives. JAPANESE DENTAL SCIENCE REVIEW 2019; 55:126-138. [PMID: 31687052 PMCID: PMC6819877 DOI: 10.1016/j.jdsr.2019.09.004] [Citation(s) in RCA: 135] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 09/13/2019] [Accepted: 09/19/2019] [Indexed: 01/27/2023] Open
Abstract
This review article compiles the characteristics of resin based dental composites and an effort is made to point out their future perspectives. Recent research studies along with few earlier articles were studied to compile the synthesis schemes of commonly used monomers, their characteristics in terms of their physical, mechanical and polymerization process with selectivity towards the input parameters of polymerization process. This review covers surface modification processes of various filler particles using silanes, wear behaviour, antimicrobial behaviour along with its testing procedures to develop the fundamental knowledge of various characteristics of resin based composites. In the end of this review, possible areas of further interests are pointed out on the basis of literature review on resin based dental materials.
Collapse
Key Words
- 4-EDMAB, Ethyl-4-dimethyl amino benzoate
- Antimicrobial properties
- BPA, Bisphenol-A
- BPO, Benzoyl peroxide
- Bis-EMA, Ethoxylatedbisphenol-A-dimethacrylate
- Bis-GMA, Bisphenol A-glycidyl methacrylate
- CQ, Camphorquinone
- DC, Degree of conversion
- DHEPT, Dihydroxy ethyl-para-toluidine
- DMAEMA, Dimethyl amino ethyl methacrylate
- DMAP, Dimethyl amino pyridine
- Dental composites
- EGDMA, Ethylene glycol dimethacrylate
- HEMA, 2-Hydroxyethyl methacrylate
- LED, Light emitting diode
- PPD, 1-phenyl-1,2 propanedione
- PS, Polymerization Shrinkage
- RBCs, Resin based composites
- Self-healing
- Surface modification of filler particles
- TEG, Triethylene glycol
- TEGDMA, Triethylene glycol dimethacrylate
- TPO, Diphenyl phosphine oxide
- UDMA, Urethane dimethacrylate
- Wear
- γ-MPS, 3-(Trimethoxysilyl) Propyl Methacrylate
Collapse
Affiliation(s)
- Bhanu Pratap
- Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, India
| | - Ravi Kant Gupta
- Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, India
| | | | - Meetu Nag
- Department of Mechatronics Engineering, Manipal University Jaipur, Jaipur, India
| |
Collapse
|
26
|
Fluorinated Montmorillonite Composite Resin as a Dental Pit and Fissure Sealant. Polymers (Basel) 2019; 11:polym11101535. [PMID: 31547022 PMCID: PMC6835378 DOI: 10.3390/polym11101535] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 09/18/2019] [Accepted: 09/18/2019] [Indexed: 11/16/2022] Open
Abstract
Molar pits and fissures tend to be affected by caries due to cleaning difficulties. As such, the filling of pits and cracks with sealants is common to deter the onset of caries. However, current clinical practices rely on sealants that lack the ability to release and recharge fluoride ions. Thus, we herein report the development of a fluoride-montmorillonite nanocomposite resin that has the potential to provide sustained release of fluoride due to the strong adsorption of fluoride by montmorillonite. X-ray diffractometry, thermogravimetric analysis, and Fourier-transform infrared spectroscopy were employed to confirm the successful insertion of the polymer into the interlayer structure. The mechanical properties (viscosity, hardening depth, hardness, diametral tensile strength, flexural strength, and wear resistance) of the developed composite resin were then examined, and simulation of the oral environment demonstrated a good fluoride ion release and recharge ability for the effective prevention of dental caries. Finally, we demonstrated the non-cytotoxic nature of this material using the water-soluble tetrazolium salt (WST-1) test. We expect that the described fluoride-containing composite resin may become a new clinical option in the near future.
Collapse
|
27
|
Kumpuga BT, Itsuno S. Synthesis of chiral polyurethanes of cinchona alkaloids for the enantioselective synthesis in asymmetric catalysis. CATAL COMMUN 2019. [DOI: 10.1016/j.catcom.2018.09.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
28
|
Song L, Ye Q, Ge X, Misra A, Tamerler C, Spencer P. New silyl-functionalized BisGMA provides autonomous strengthening without leaching for dental adhesives. Acta Biomater 2019; 83:130-139. [PMID: 30366133 DOI: 10.1016/j.actbio.2018.10.033] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 09/30/2018] [Accepted: 10/22/2018] [Indexed: 12/27/2022]
Abstract
Resin-based composite has overtaken dental amalgam as the most popular material for direct restorative dentistry. In spite of this popularity the clinical lifetime of composite restorations is threatened by recurrent decay. Degradation of the adhesive leads to gaps at the composite/tooth interface-bacteria, bacterial by-products and fluids infiltrate the gaps leading to recurrent decay and composite restoration failure. The durability of resin-dentin bonds is a major problem. We address this problem by synthesizing silyl-functionalized BisGMA (e.g., silyl-BisGMA), formulating dental adhesives with the new monomer and determining the physicochemical properties and leaching characteristics of the silyl-BisGMA adhesives. Silyl-BisGMA was synthesized by stoichiometric amounts of BisGMA and 3-isocyanatopropyl trimethoxysilane (IPTMS). The control adhesive was a mixture based on HEMA/BisGMA (45/55, w/w). In the experimental formulations, BisGMA was partially or completely replaced by silyl-BisGMA. Water miscibility, polymerization behavior (Fourier transform infrared spectroscopy, FTIR), thermal property (modulated differential scanning calorimetry, MDSC), mechanical properties in dry and wet conditions (dynamic mechanical analysis, DMA), and leached species (HPLC) were investigated. Data from all tests were submitted to appropriate statistical analysis (α = 0.05). Silyl-BisGMA-containing adhesives exhibited comparable water miscibility, lower viscosities, and significantly improved degree of conversion of CC bond as compared to the control. After 4 weeks aqueous aging, the glass transition temperature and rubbery moduli of the experimental copolymers were significantly greater than the control (p < 0.05). HPLC results indicated a substantial reduction of leached HEMA (up to 99 wt%) and BisGMA (up to 90 wt%). By introducing silyl-functional group, the new BisGMA derivative exhibited potential as a monomer that can lead to dental adhesives with improved mechanical properties and reduced leaching under conditions relevant to the oral environment. STATEMENT OF SIGNIFICANCE: The low-viscosity adhesive that bonds the composite to the tooth (enamel and dentin) is intended to seal and stabilize the composite/tooth interface, but it degrades leading to a breach at the composite/tooth margin. As the most popular crosslinking monomer in adhesives, Bisphenol A-glycerolate dimethacrylate (BisGMA) has limitations, e.g. susceptible to hydrolysis and concomitant property degradation. A methoxysilyl-functionalized BisGMA derivative (silyl-BisGMA) was introduced in this work to respond to these limitations. Our results indicated that by introducing silyl-BisGMA, higher crosslinked networks were obtained without sacrificing the homogeneity, and the leached amount of HEMA was reduced up to 99%. This novel resin offers potential benefits including prolonging the functional lifetime of dental resin materials.
Collapse
|
29
|
Lempel E, Őri Z, Szalma J, Lovász BV, Kiss A, Tóth Á, Kunsági-Máté S. Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber reinforced and polyacid-modified resin composites. Dent Mater 2018; 35:217-228. [PMID: 30503020 DOI: 10.1016/j.dental.2018.11.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 10/03/2018] [Accepted: 11/14/2018] [Indexed: 01/16/2023]
Abstract
OBJECTIVE To determine the degree of conversion (DC) of different type of resin-based composites (RBC) in eight-millimeter-deep clinically relevant molds, and investigate the influence of exposure time and pre-heating on DC. METHODS Two-millimeter-thick samples of conventional sculptable [FiltekZ250 (FZ)], flowable [Filtek Ultimate Flow (FUF)] and polyacid-modified [Twinky Star Flow (TS)] RBCs, and four-millimeter-thick samples of flowable bulk-fill [Filtek Bulk Fill Flow (FBF), Surefil SDR (SDR)] and sculptable fibre-reinforced [EverX Posterior (EX)] RBCs were prepared in an eight-millimeter-deep mold. The RBCs temperature was pre-set to 25, 35 and 55°C. The RBCs were photopolymerized with the recommended and its double exposure time. The DC at the top and bottom was measured with micro-Raman spectroscopy. Data were analyzed with ANOVA and Scheffe post-hoc test (p<0.05). RESULTS The differences in DC% between the top/bottom and the recommended/extended exposure time were significant for the materials, except SDR (64.5/63.0% and 67.4/63.0%). FUF (69.0% and 53.4%) and TS (64.9% and 60.9%) in 2mm provided higher DC% at the top and bottom with the recommended curing time, compared to the other materials, except SDR. Pre-heating had negative effect on DC at the bottom in flowable RBCs (FUF: 48.9%, FBF: 36.7%, SDR: 43%, TS: 54.7%). Pre-heating to 55 °C significantly increased the DC% in fibre-reinforced RBC (75.0% at the top, 64.7% at the bottom). SIGNIFICANCE Increased exposure time improves the DC for each material. Among bulk-fills, only SDR performed similarly, compared to the two-millimeter-thick flowable RBCs. Pre-heating of low-viscosity RBCs decreased the DC% at the bottom. Pre-heating of fibre-reinforced RBC to 55°C increased the DC% at a higher rate than the extended curing time.
Collapse
Affiliation(s)
- Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary.
| | - Zsuzsanna Őri
- Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs, H-7624, Hungary; János Szentágothai Research Center, 20 Ifjúság Street, Pécs, H-7624, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs, Pécs, Hungary
| | - Bálint Viktor Lovász
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary
| | - Adél Kiss
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary
| | - Ákos Tóth
- Faculty of Sciences, University of Pécs Pécs, Hungary
| | - Sándor Kunsági-Máté
- Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs, H-7624, Hungary; János Szentágothai Research Center, 20 Ifjúság Street, Pécs, H-7624, Hungary
| |
Collapse
|
30
|
Evaluation of the filler packing structures in dental resin composites: From theory to practice. Dent Mater 2018; 34:1014-1023. [DOI: 10.1016/j.dental.2018.03.022] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Accepted: 03/24/2018] [Indexed: 01/24/2023]
|
31
|
Xu Y, Zhang J, Wang H, Xie D. Preparation of a low viscosity urethane-based composite for improved dental restoratives. Dent Mater J 2018; 37:400-407. [PMID: 29553122 DOI: 10.4012/dmj.2017-162] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Several new urethane-based dimethacrylates were synthesized, characterized and used to formulate the resin composites. Compressive strength (CS) was used as a screen tool to evaluate the mechanical property of the formed composites. Flexural strength, diametral tensile strength, water sorption, degree of conversion and shrinkage of the composites were also evaluated. The results show that most of the synthesized urethane-based dimethacrylates were solid, which are not suitable to dental filling restorations. However, it was found that liquid urethane-based dimethacrylates could be derivatized using asymmetrical methacrylate synthesis. Not only the newly synthesized urethane-based dimethacrylates showed lower viscosity values but also their constructed composites exhibited higher mechanical strengths. Without triethyleneglycol dimethacrylate (TEGDMA) addition, the new urethane-constructed composites showed significantly lower water sorption and shrinkage.
Collapse
Affiliation(s)
- Yuling Xu
- College of Chemical and Environmental Engineering, Wuhan Polytech University.,Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis
| | - Juntao Zhang
- College of Chemical and Environmental Engineering, Wuhan Polytech University
| | - Haibo Wang
- College of Chemical and Environmental Engineering, Wuhan Polytech University
| | - Dong Xie
- Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis
| |
Collapse
|
32
|
He J, Garoushi S, Vallittu PK, Lassila L. Effect of low-shrinkage monomers on the physicochemical properties of experimental composite resin. ACTA BIOMATERIALIA ODONTOLOGICA SCANDINAVICA 2018. [PMID: 29536025 PMCID: PMC5844030 DOI: 10.1080/23337931.2018.1444488] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study was conducted to determine whether novel experimental low-shrinkage dimethacrylate co-monomers could provide low polymerization shrinkage composites without sacrifice to degree of conversion, and mechanical properties of the composites. Experimental composites were prepared by mixing 28.6 wt% of bisphenol-A-glycidyl dimethacrylate based resin matrix (bis-GMA) with various weight-fractions of co-monomers; tricyclo decanedimethanol dacrylate (SR833s) and isobornyl acrylate (IBOA) to 71.4 wt% of particulate-fillers. A composite based on bis-GMA/TEGDMA (triethylene glycol dimethacrylate) was used as a control. Fracture toughness and flexural strength were determined for each experimental material following international standards. Degree of monomer-conversion (DC%) was determined by FTIR spectrometry. The volumetric shrinkage in percent was calculated as a buoyancy change in distilled water by means of the Archimedes’ principle. Polymerization shrinkage-strain and -stress of the specimens were measured using the strain-gage technique and tensilometer, respectively with respect to time. Statistical analysis revealed that control group had the highest double-bond conversion (p < .05) among the experimental resins tested. All of the experimental composite resins had comparable flexural strength, modulus, and fracture toughness (p > .05). Volumetric shrinkage and shrinkage stress decreased with increasing IBOA concentration. Replacing TEGDMA with SR833s and IBOA can decrease the volumetric shrinkage, shrinkage strain, and shrinkage stress of composite resins without affecting the mechanical properties. However, the degree of conversion was also decreased.
Collapse
Affiliation(s)
- Jingwei He
- Department of Biomaterials Science, Turku Clinical Biomaterials Center (TCBC), Institute of Dentistry, University of TurkuTurkuFinland.,College of Materials Science and Engineering, South China University of TechnologyGuangzhouChina
| | - Sufyan Garoushi
- Department of Biomaterials Science, Turku Clinical Biomaterials Center (TCBC), Institute of Dentistry, University of TurkuTurkuFinland
| | - Pekka K Vallittu
- Department of Biomaterials Science, Turku Clinical Biomaterials Center (TCBC), Institute of Dentistry, University of TurkuTurkuFinland.,City of Turku Welfare Division, Oral Health CareTurkuFinland
| | - Lippo Lassila
- Department of Biomaterials Science, Turku Clinical Biomaterials Center (TCBC), Institute of Dentistry, University of TurkuTurkuFinland
| |
Collapse
|
33
|
Huang S, Podgórski M, Zhang X, Sinha J, Claudino M, Stansbury JW, Bowman CN. Dental Restorative Materials Based on Thiol-Michael Photopolymerization. J Dent Res 2018; 97:530-536. [PMID: 29439642 DOI: 10.1177/0022034518755718] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Step-growth thiol-Michael photopolymerizable resins, constituting an alternative chemistry to the current methacrylate-based chain-growth polymerizations, were developed and evaluated for use as dental restorative materials. The beneficial features inherent to anion-mediated thiol-Michael polymerizations were explored, such as rapid photocuring, low stress generation, ester content tunability, and improved mechanical performance in a moist environment. An ester-free tetrafunctional thiol and a ultraviolet-sensitive photobase generator were implemented to facilitate thiol-Michael photopolymerization. Thiol-Michael resins of varied ester content were fabricated under suitable light activation. Polymerization kinetics and shrinkage stress were determined with Fourier-transform infrared spectroscopy coupled with tensometery measurements. Thermomechanical properties of new materials were evaluated by dynamic mechanical analysis and in 3-point bending stress-strain experiments. Photopolymerization kinetics, polymerization shrinkage stress, glass transition temperature, flexural modulus, flexural toughness, and water sorption/solubility were compared between different thiol-Michael systems and the BisGMA/TEGDMA control. Furthermore, the mechanical performance of 2 thiol-Michael composites and a control composite were compared before and after extensive conditioning in water. All photobase-catalyzed thiol-Michael polymerization matrices achieved >90% conversion with a dramatic reduction in shrinkage stress as compared with the unfilled dimethacrylate control. One prototype of ester-free thiol-Michael formulations had significantly better water uptake properties than the BisGMA/TEGDMA control system. Although exhibiting relatively lower Young's modulus and glass transition temperatures, highly uniform thiol-Michael materials achieved much higher toughness than the BisGMA/TEGDMA control. Moreover, low-ester thiol-Michael composite systems show stable mechanical performance even after extensive water treatment. Although further resin/curing methodology optimization is required, the photopolymerized thiol-Michael prototype resins can now be recognized as promising candidates for implementation in composite dental restorative materials.
Collapse
Affiliation(s)
- S Huang
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA
| | - M Podgórski
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA.,2 Department of Polymer Chemistry, Faculty of Chemistry, MCS University, Lublin, Poland
| | - X Zhang
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA
| | - J Sinha
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA
| | - M Claudino
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA
| | - J W Stansbury
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA.,3 Department of Craniofacial Biology, School of Dental Medicine, Anschutz Medical Campus, Aurora, CO, USA
| | - C N Bowman
- 1 Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA
| |
Collapse
|
34
|
Xu Y, Wang H, Xie D. Preparation of new low viscosity urethane dimethacrylates for dental composites. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2017; 29:1011-1025. [PMID: 28784029 DOI: 10.1080/09205063.2017.1364098] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Urethane-based polymers are very biocompatible in many biomedical applications. This study reports the synthesis of new low viscosity urethane dimethacrylates and evaluation of the formed composites. New urethane dimethacrylates were synthesized and formulated to form the composites. Compressive strength was used as a primary tool to evaluate the mechanical property. Water sorption, solubility, degree of conversion, flexural strengths and shrinkage were also investigated. It was found that liquid urethane dimethacrylates could be synthesized by derivatizing isocyanates with asymmetrical methacrylates. By eliminating diluent triethylene glycol dimethacrylate, the new urethane dimethacrylate-composed composites showed significantly higher modulus, lower water sorption, lower solubility and lower shrinkage, as compared to commercial BisGMA- and UDMA-based ones.
Collapse
Affiliation(s)
- Yuling Xu
- a College of Chemical and Environmental Engineering , Wuhan Polytech University , Wuhan , China.,b Department of Biomedical Engineering, Purdue School of Engineering and Technology , Indiana University-Purdue University at Indianapolis , Indianapolis , IN , USA
| | - Haibo Wang
- a College of Chemical and Environmental Engineering , Wuhan Polytech University , Wuhan , China
| | - Dong Xie
- b Department of Biomedical Engineering, Purdue School of Engineering and Technology , Indiana University-Purdue University at Indianapolis , Indianapolis , IN , USA
| |
Collapse
|
35
|
Long F, Intes X. Dental optical tomography with upconversion nanoparticles-a feasibility study. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:66001. [PMID: 28586852 PMCID: PMC5456002 DOI: 10.1117/1.jbo.22.6.066001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Accepted: 05/05/2017] [Indexed: 05/30/2023]
Abstract
Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications.
Collapse
Affiliation(s)
- Feixiao Long
- Rensselaer Polytechnic Institute, Biomedical Engineering, Troy, New York, United States
| | - Xavier Intes
- Rensselaer Polytechnic Institute, Biomedical Engineering, Troy, New York, United States
| |
Collapse
|
36
|
Moharam LM, El-Hoshy AZ, Abou-Elenein K. The effect of different insertion techniques on the depth of cure and vickers surface micro-hardness of two bulk-fill resin composite materials. J Clin Exp Dent 2017; 9:e266-e271. [PMID: 28210447 PMCID: PMC5303329 DOI: 10.4317/jced.53356] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 07/18/2016] [Indexed: 11/17/2022] Open
Abstract
Background The aim of this study was to evaluate the Vickers surface micro-hardness and the depth of cure of two bulk-fill resin composites and one incremental-fill resin composite. Material and Methods Two Bulk-fill dental resin composites (X-tra Fil, Voco; Sonic-FillTM 2, Kerr Corporation) and an incremental-fill dental resin composite (Filtek™ Z250 XT, 3M ESPE) were used. Sixty cylindrical specimens of 4 mm thickness were prepared using split Teflon moulds. Specimens were divided into six groups (n=10) according to the type of the material used and according to the insertion technique applied (bulk or incremental). Prepared specimens were stored dry in complete darkness at 37°C for 24 hours. All specimens were tested for their Vickers surface micro-hardness, on their top and bottom surfaces. The depth of cure of the tested specimens was assessed by calculating the hardness ratio for each specimen. The Vickers surface micro-hardness and depth of cure data were analyzed for normality using Kolmogorov-Smirnov and Shapiro-Wilk tests. Independent sample-t test was used to compare between two groups while One-way ANOVA was used to compare between more than two groups. Results Significant difference in the Vickers surface micro-hardness and depth of cure values was demonstrated among the tested materials (P<0.0001). X-tra Fil recorded the highest mean Vickers micro-hardness value (94.05±1.05). Bulk-fill dental resin composites X-tra Fil and Sonic-Fill showed 0.980±0.005 and 0.921±0.020 depth of cure values (bottom/top hardness ratio) respectively while Z250 XT recorded 0.776±0.141. Conclusions X-tra Fil showed highest Vickers surface micro-hardness values on both top and bottom surfaces, whether inserted in increments or bulk. Both bulk-fill resin composites showed higher depth of cure for both insertion techniques. Key words:Depth of cure, Vickers surface micro-hardness, bulk-fill resin composite, insertion techniques.
Collapse
Affiliation(s)
- Lamiaa-Mahmoud Moharam
- Restorative and Dental Materials Research department, National Research Centre, Giza, Egypt
| | | | - Karim Abou-Elenein
- Operative Dentistry department, Faculty of Oral and Dental medicine, Cairo, Egypt
| |
Collapse
|
37
|
Tay F, Pashley D, Kapur R, Carrilho M, Hur Y, Garrett L, Tay K. Bonding BisGMA to Dentin—a Proof of Concept for Hydrophobic Dentin Bonding. J Dent Res 2016; 86:1034-9. [PMID: 17959892 DOI: 10.1177/154405910708601103] [Citation(s) in RCA: 120] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The use of TEGDMA as a diluent comonomer in the formulation of hydrophobic adhesives for ethanol wet-bonding is a concern, due to its leaching potential, higher water sorption, and bio-incompatibility. This study tested the hypothesis that hydrophobic bonding to acid-etched dentin may be accomplished with the use of ethanol-solvated BisGMA only. Phosphoric-acid-etched, oxalate-occluded, deep coronal dentin bonded under 20 cm water pressure with experimental BisGMA adhesives by ethanol wet-bonding exhibited tensile strengths that were not significantly different from that achieved with OptiBond FL bonded according to the manufacturer-recommended protocol, with similar acid-/base-resistant hybrid layers, resin tags, and nanoleakage distribution. Ethanol replacement of water-saturated dentin produced wider interfibrillar spaces, more extensive shrinkage of the collagen fibrils, and narrower hybrid layers. Experimental BisGMA adhesives provide the proof of concept that relatively hydrophobic resins may be coupled to acid-etched dentin by increasing its hydrophobic characteristics via ethanol replacement. They should be further optimized before clinical application.
Collapse
Affiliation(s)
- F.R. Tay
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| | - D.H. Pashley
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| | - R.R. Kapur
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| | - M.R.O. Carrilho
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| | - Y.B. Hur
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| | - L.V. Garrett
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| | - K.C.Y. Tay
- Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
- School of Dentistry, Medical College of Georgia, Augusta, GA, USA
- Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Piracicaba, SP, Brazil; and
- University of Toronto, Ontario, Canada
| |
Collapse
|
38
|
Martim GC, Pfeifer CS, Girotto EM. Novel urethane-based polymer for dental applications with decreased monomer leaching. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 72:192-201. [PMID: 28024577 DOI: 10.1016/j.msec.2016.11.050] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 10/18/2016] [Accepted: 11/13/2016] [Indexed: 11/15/2022]
Abstract
The aim of this study was to synthesize and characterize new multifunctional-urethane-methacrylate monomers to be used as the organic matrix in restorative dental composites, and evaluate the main physical-chemical properties of the resulting material. Bis-GMA (bisphenol-A-diglycidylmethacrylate) and GDMA (glycerol dimethacrylate) were modified by reacting the hydroxyl groups with isocyanate groups of urethane-methacrylate precursors to result in the new monomeric systems U-(bis-GMA)-Mod and U-(GDMA)-Mod, U=Urethane and Mod=Modified. The modifications were characterized by FTIR and 1H NMR. The final monomeric synthesized system was used to prepare dental resins and composites. The physical-chemical properties were evaluated and compared with those of bis-GMA composites with varying filler contents or unfilled resins. U-(bis-GMA)-Mod and U-(GDMA)-Mod can be used to prepare dental restorative composites, with some foreseeable advantages compared with bis-GMA composites. One significant advantage is that these composites have the potential to be less toxic, once they presented a reduction of 50% in leaching of unreacted monomers extracted by solvent.
Collapse
Affiliation(s)
- Gedalias C Martim
- Materials Chemistry and Sensors Laboratories, Department of Chemistry, Universidade Estadual de Maringá, Av. Colombo 5790, 87020-900 Maringá, Paraná, Brazil
| | - Carmem S Pfeifer
- Biomaterials and Biomechanics, Oregon Health and Science University, 611 SW Campus Dr, Portland, OR 97239, USA
| | - Emerson M Girotto
- Materials Chemistry and Sensors Laboratories, Department of Chemistry, Universidade Estadual de Maringá, Av. Colombo 5790, 87020-900 Maringá, Paraná, Brazil.
| |
Collapse
|
39
|
Melinte V, Buruiana T, Chibac A, Mares M, Aldea H, Buruiana EC. New acid BisGMA analogs for dental adhesive applications with antimicrobial activity. Dent Mater 2016; 32:e314-e326. [PMID: 27671467 DOI: 10.1016/j.dental.2016.09.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 07/08/2016] [Accepted: 09/03/2016] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To achieve bisphenol A glycerolate dimethacrylate (BisGMA) analogs with reduced viscosity to be used in the formulation of dental adhesives containing biocidal components. METHODS A series of low-viscosity BisGMA derivatives (η: 39-12Pas) modified with 30, 60 and, respectively 80mol% carboxylic acid units were synthesized and characterized. Hydrogen bonding interactions in our monomers, the photopolymerization behavior and implicitly the conversion degree (DC) for some experimental adhesive formulations containing acid-modified BisGMA, commercial BisGMA (only in F1-F3), triethyleneglycol dimethacrylate and 2-hydroxyethyl methacrylate were examined by FTIR spectroscopy. The water effects on the photocrosslinked networks together with the flexural strength/modulus were also investigated. The adhesive penetration into the dentin surface was surveyed by SEM analysis, and the antimicrobial activity triggered by the incorporation of 0.5wt% AgNO3, 10wt% zinc methacrylate or 1wt% triclosan methacrylate in selected adhesive formulations on the growth of Streptococcus mutans and Candida albicans strains was evidenced. RESULTS The contribution of the hydrogen bonding interactions was found to be lower in BisGMA derivatives than in non-modified BisGMA, and the DC varied between 56.5 (F6) and 83.7% (F1) compared with a control formulation based on BisGMA:TEGDMA (DC=58.2%). The flexural strength and flexural modulus varied in the range 33.7MPa (F6)-54.4MPa (F8)MPa and 0.64 (F6)-1.43 (F8)GPa, respectively. SEM observation of adhesive-dentin interface revealed the formation of resin tags for the carboxyl-containing adhesive, while for the control adhesive they are hardly formed. Also, the microorganism development was inhibited, the proposed materials displaying antimicrobial activity. SIGNIFICANCE The experimental formulations based on carboxyl-functionalized BisGMA exhibit a similar or even improved behavior over control sample, suggesting their potential applicability as antimicrobial dental adhesives.
Collapse
Affiliation(s)
- Violeta Melinte
- Polyaddition and Photochemistry Department, Petru Poni Institute of Macromolecular Chemistry, 41 A Gr. Ghica Voda Alley, 700487 Iasi, Romania
| | - Tinca Buruiana
- Polyaddition and Photochemistry Department, Petru Poni Institute of Macromolecular Chemistry, 41 A Gr. Ghica Voda Alley, 700487 Iasi, Romania.
| | - Andreea Chibac
- Polyaddition and Photochemistry Department, Petru Poni Institute of Macromolecular Chemistry, 41 A Gr. Ghica Voda Alley, 700487 Iasi, Romania
| | - Mihai Mares
- Laboratory of Antimicrobial Chemotherapy, "Ion Ionescu de la Brad" University, 8 Sadoveanu Alley, 700489 Iasi, Romania
| | - Horia Aldea
- Dental Office, 17 T. Vladimirescu Street, Iasi, Romania
| | - Emil C Buruiana
- Polyaddition and Photochemistry Department, Petru Poni Institute of Macromolecular Chemistry, 41 A Gr. Ghica Voda Alley, 700487 Iasi, Romania
| |
Collapse
|
40
|
Song HB, Sowan N, Shah PK, Baranek A, Flores A, Stansbury JW, Bowman CN. Reduced shrinkage stress via photo-initiated copper(I)-catalyzed cycloaddition polymerizations of azide-alkyne resins. Dent Mater 2016; 32:1332-1342. [PMID: 27524230 DOI: 10.1016/j.dental.2016.07.014] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2016] [Accepted: 07/25/2016] [Indexed: 12/20/2022]
Abstract
OBJECTIVES Polymerization shrinkage stress and factors involved in the stress development such as volumetric shrinkage and modulus were investigated in photo-CuAAC (photo-initiated copper(I)-catalyzed azide-alkyne cycloaddition) polymerization and compared with conventional BisGMA-based methacrylate polymerization for their use as alternative dental resins. METHODS Tri-functional alkyne and di-functional azide monomers were synthesized for photo-CuAAC polymerization. Conversion kinetics, stress development and polymerization shrinkage were determined with FTIR spectroscopy, tensometery, and with a linometer, respectively, for CuAAC and BisGMA-based monomer mixtures using a camphorquinone/amine visible light photoinitiator system. Thermo-mechanical properties for the cured polymer matrices were characterized by dynamic mechanical analysis and in three-point bending on a universal testing machine. Polymerization kinetics, polymerization shrinkage stress, dynamic volumetric shrinkage, glass transition temperature (Tg), flexural modulus, flexural strength, and flexural toughness were compared between the two different resin systems. RESULTS A glassy CuAAC polymer (Tg=62°C) exhibited 15-25% lower flexural modulus of 2.5±0.2GPa and flexural strength of 117±8MPa compared to BisGMA-based polymer (Tg=160°C) but showed considerably higher energy absorption around 7.1MJ×m-3 without fracture when strained to 11% via three-point bend compared to the flexural toughness of 2.7MJ×m-3 obtained from BisGMA-based polymer. In contrast to BisGMA-based polymers at 75% functional group conversion, the CuAAC polymerization developed approximately three times lower shrinkage stress with the potential to achieve quantitative conversion under ambient temperature photocuring conditions. Moreover, relatively equivalent dynamic volumetric shrinkage of around 6-7% was observed via both CuAAC and dimethacrylate polymerization, suggesting that the low shrinkage stress of CuAAC polymerization was due to delayed gelation along with slower rate of polymerization and the formation of a more compliant network structure. SIGNIFICANCE CuAAC crosslinked networks possessed high toughness and low polymerization shrinkage stress with quantitative conversion, which eliminated obstacles associated with BisGMA-based dental resins including limited conversion, unreacted extractable moieties, brittle failure, and high shrinkage stress.
Collapse
Affiliation(s)
- Han Byul Song
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Nancy Sowan
- Materials Science and Engineering Program, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Parag K Shah
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Austin Baranek
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Alexander Flores
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States
| | - Jeffrey W Stansbury
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States; Department of Craniofacial Biology, School of Dental Medicine, Anschutz Medical Campus, Aurora, CO, United States
| | - Christopher N Bowman
- Department of Chemical and Biological Engineering, University of Colorado Boulder, 596 UCB, Boulder, CO, United States; Materials Science and Engineering Program, University of Colorado Boulder, 596 UCB, Boulder, CO, United States.
| |
Collapse
|
41
|
Degree of Conversion and BisGMA, TEGDMA, UDMA Elution from Flowable Bulk Fill Composites. Int J Mol Sci 2016; 17:ijms17050732. [PMID: 27213361 PMCID: PMC4881554 DOI: 10.3390/ijms17050732] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 05/04/2016] [Accepted: 05/09/2016] [Indexed: 01/11/2023] Open
Abstract
The degree of conversion (DC) and the released bisphenol A diglycidyl ether dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) monomers of bulk-fill composites compared to that of conventional flowable ones were assessed using micro-Raman spectroscopy and high performance liquid chromatography (HPLC). Four millimeter-thick samples were prepared from SureFil SDR Flow (SDR), X-tra Base (XB), Filtek Bulk Fill (FBF) and two and four millimeter samples from Filtek Ultimate Flow (FUF). They were measured with micro-Raman spectroscopy to determine the DC% of the top and the bottom surfaces. The amount of released monomers in 75% ethanol extraction media was measured with HPLC. The differences between the top and bottom DC% were significant for each material. The mean DC values were in the following order for the bottom surfaces: SDR_4mm_20s > FUF_2mm_20s > XB_4mm_20s > FBF_4mm_20s > XB_4mm_10s > FBF_4mm_10s > FUF_4mm_20s. The highest rate in the amount of released BisGMA and TEGDMA was found from the 4 mm-thick conventional flowable FUF. Among bulk-fills, FBF showed a twenty times higher amount of eluted UDMA and twice more BisGMA; meanwhile, SDR released a significantly higher amount of TEGDMA. SDR bulk-fill showed significantly higher DC%; meanwhile XB, FBF did not reach the same level DC, as that of the 2 mm-thick conventional composite at the bottom surface. Conventional flowable composites showed a higher rate of monomer elution compared to the bulk-fills, except FBF, which showed a high amount of UDMA release.
Collapse
|
42
|
Shen L, Zheng J, Wang Y, Lu M, Wu K. Influence of hydrogen bonding interactions on the properties of ultraviolet-curable coatings. J Appl Polym Sci 2016. [DOI: 10.1002/app.43113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Lu Shen
- Key Laboratory of Cellulose and Lignocellulosics Chemistry; Guangzhou Institute of Chemistry, Chinese Academy of Sciences; Guangzhou People's Republic of China
- University of Chinese Academy of Sciences; Beijing People's Republic of China
| | - Jian Zheng
- Key Laboratory of Cellulose and Lignocellulosics Chemistry; Guangzhou Institute of Chemistry, Chinese Academy of Sciences; Guangzhou People's Republic of China
- University of Chinese Academy of Sciences; Beijing People's Republic of China
| | - Ying Wang
- Key Laboratory of Cellulose and Lignocellulosics Chemistry; Guangzhou Institute of Chemistry, Chinese Academy of Sciences; Guangzhou People's Republic of China
- University of Chinese Academy of Sciences; Beijing People's Republic of China
| | - Mangeng Lu
- Key Laboratory of Cellulose and Lignocellulosics Chemistry; Guangzhou Institute of Chemistry, Chinese Academy of Sciences; Guangzhou People's Republic of China
| | - Kun Wu
- Key Laboratory of Cellulose and Lignocellulosics Chemistry; Guangzhou Institute of Chemistry, Chinese Academy of Sciences; Guangzhou People's Republic of China
| |
Collapse
|
43
|
Sun J, Watson SS, Allsopp DA, Stanley D, Skrtic D. Tuning photo-catalytic activities of TiO2 nanoparticles using dimethacrylate resins. Dent Mater 2016; 32:363-72. [PMID: 26792622 DOI: 10.1016/j.dental.2015.11.021] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Revised: 08/20/2015] [Accepted: 11/30/2015] [Indexed: 12/17/2022]
Abstract
OBJECTIVE The unique photo-catalytic activities (PCAs) of titanium dioxide nanoparticles (TiO2 NPs) made them attractive in many potential applications in medical devices. The objective of this study is to optimize the benefits of PCAs of TiO2 NPs through varying chemical structures of dimethacrylate resins. METHODS TiO2 NPs were functionalized to improve the PCAs and bonding to the resins. The PCAs of TiO2 NPs were evaluated using electron paramagnetic resonance (EPR) and UV-vis spectroscopy to determine the amount of the radicals generated and the energy required for their production, respectively. The beneficial effects of the radicals were assessed through: (1) the improvement of degree of vinyl conversion (DC) and (2) modification of resin hydrophilicity. One-way ANOVA with a 95% confidence interval was used to indicate the significant differences between the experimental groups. RESULTS EPR and UV-vis results clearly showed that the functionalization of TiO2 NPs enhanced PCAs in terms of generating radicals under visible light irradiation. The presence of hydroxyl and carboxylic acid functionalities played an important role in DC enhancement and hydrophilicity modification. The DC could be increased up to 22% by adding only 0.1wt% TiO2 NPs. Viscosity of the resins had minimal or no role in DC improvement through TiO2 NPs. In resins with abundant hydroxyl groups, radicals were more effective in making the resin more hydrophilic. SIGNIFICANCE Knowledge learned from this study will help formulating nano-composites with optimized use of TiO2 PCAs as co-initiators for photo-polymerization, additives for making super-hydrophilic materials and/or antibacterial agents.
Collapse
Affiliation(s)
- Jirun Sun
- Dr Anthony Volpe Research Center, American Dental Association Foundation, Gaithersburg, MD 20899, USA.
| | - Stephanie S Watson
- Polymeric Materials Group, Materials and Structural Systems Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| | - David A Allsopp
- Dr Anthony Volpe Research Center, American Dental Association Foundation, Gaithersburg, MD 20899, USA
| | - Debbie Stanley
- Polymeric Materials Group, Materials and Structural Systems Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| | - Drago Skrtic
- Dr Anthony Volpe Research Center, American Dental Association Foundation, Gaithersburg, MD 20899, USA
| |
Collapse
|
44
|
Petropoulou A, Vrochari AD, Hellwig E, Stampf S, Polydorou O. Water sorption and water solubility of self-etching and self-adhesive resin cements. J Prosthet Dent 2015; 114:674-9. [DOI: 10.1016/j.prosdent.2015.06.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Revised: 06/01/2015] [Accepted: 06/05/2015] [Indexed: 11/30/2022]
|
45
|
Aljabo A, Xia W, Liaqat S, Khan MA, Knowles JC, Ashley P, Young AM. Conversion, shrinkage, water sorption, flexural strength and modulus of re-mineralizing dental composites. Dent Mater 2015; 31:1279-89. [PMID: 26361809 DOI: 10.1016/j.dental.2015.08.149] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Revised: 06/15/2015] [Accepted: 08/14/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES Cure, volumetric changes and mechanical properties were assessed for new dental composites containing chlorhexidine (CHX) and reactive calcium phosphate-containing (CaP) to reduce recurrent caries. METHODS 20wt.% of light curable urethane dimethacrylate based liquid was mixed with 80wt.% glass filler containing 10wt.% CHX and 0-40wt.% CaP. Conversion versus depth with 20 or 40s light exposure was assessed by FTIR. Solidification depth and polymerization shrinkage were determined using ISO 4049 and 17304, respectively. Subsequent volume expansion and biaxial flexural strength and modulus change upon water immersion were determined over 4 weeks. Hydroxyapatite precipitation in simulated body fluid was assessed at 1 week. RESULTS Conversion decreased linearly with both depth and CaP content. Average solidification depths were 4.5, 3.9, 3.3, 2.9 and 5.0 with 0, 10, 20, and 40% CaP and a commercial composite, Z250, respectively. Conversions at these depths were 53±2% for experimental materials but with Z250 only 32%. With Z250 more than 50% conversion was achieved only below 1.1mm. Shrinkage was 3% and 2.5% for experimental materials and Z250, respectively. Early water sorption increased linearly, whilst strength and modulus decreased exponentially to final values when plotted versus square root of time. Maximum volumetric expansion increased linearly with CaP rise and balanced shrinkage at 10-20wt.% CaP. Strength and modulus for Z250 decreased from 191 to 158MPa and 3.2 to 2.5GPa. Experimental composites initial strength and modulus decreased linearly from 169 to 139MPa and 5.8 to 3.8GPa with increasing CaP. Extrapolated final values decreased from 156 to 84MPa and 4.1 to 1.7GPa. All materials containing CaP promoted hydroxyapatite precipitation. SIGNIFICANCE The lower surface of composite restorations should both be solid and have greater than 50% conversion. The results, therefore, suggest the experimental composite may be placed in much thicker layers than Z250 and have reduced unbounded cytotoxic monomer. Experimental materials with 10-20wt.% additionally have volumetric expansion to compensate shrinkage, antibacterial and re-mineralizing components and competitive mechanical properties.
Collapse
Affiliation(s)
- A Aljabo
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK
| | - W Xia
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK
| | - S Liaqat
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK
| | - M A Khan
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK
| | - J C Knowles
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK
| | - P Ashley
- Department of Paediatric Dentistry, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK
| | - A M Young
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, UK.
| |
Collapse
|
46
|
Liu F, Jiang X, Bao S, Wang R, Sun B, Zhu M. Effect of hydroxyapatite whisker surface graft polymerization on water sorption, solubility and bioactivity of the dental resin composite. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 53:150-5. [DOI: 10.1016/j.msec.2015.04.043] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2014] [Revised: 03/13/2014] [Accepted: 04/21/2015] [Indexed: 11/30/2022]
|
47
|
Degree of conversion and surface hardness of bulk-fill composite versus incremental-fill composite. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.tdj.2015.01.003] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
48
|
Abstract
Objectives:The aim of this study was to compare colour stability of two self-adhesive flowable composites with four methacrylate-based composites (three flowable composites and one universal resin-based composite) after immersion in water at 60°C for 30 days.Methods:The study was conducted using the following five shade A2 flowable composites (n=30): one microhybrid (G-aenial Universal Flo), one universal (X-Flow), one nanohybrid (Premise flowable) and two self-adhesive (Vertise Flow and experimental GF-10) and one microhybrid universal resin-based composite (G-aenial Posterior). A spectrophotometer (CIEL*a*b* system) was used to measure colour stability before and after immersion. Statistical analysis was performed with one-way ANOVA and Fisher test.Results:Samples immersed in water at 60°C for one month showed a significant colour change in all groups (p<.001) that was visually perceptible (∆E>3.3). Experimental self-adhesive flowable (12.25±0.84) and X-Flow (11.56±3.26) composites showed higher levels of ∆E, while Premise flowable showed a lower level of colour change (3.47±1.26). These results approximated clinically acceptable colour change values (∆E≤3.3). Water ageing at 60°C produced a significant change in colour in all the composites. The high temperature may explain the degradation of the resin matrix.
Collapse
|
49
|
Béhin P, Stoclet G, Ruse ND, Sadoun M. Dynamic mechanical analysis of high pressure polymerized urethane dimethacrylate. Dent Mater 2014; 30:728-34. [DOI: 10.1016/j.dental.2014.04.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 02/21/2014] [Accepted: 04/07/2014] [Indexed: 11/29/2022]
|
50
|
Herrera-González AM, D'Accorso NB, Cuevas-Suárez CE, Fascio ML, García-Serrano J, Alho MM, Zamarripa-Calderón JE. Composite resins based on novel and highly reactive bisglycidyl methacrylate monomers. J Appl Polym Sci 2014. [DOI: 10.1002/app.40971] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Ana María Herrera-González
- Universidad Autónoma del Estado de Hidalgo - Instituto de Ciencias Básicas e Ingeniería, Carretera Pachuca-Tulancingo Km. 4.5 Colonia Carboneras, Mineral de la Reforma; Hidalgo 42183 México
| | - Norma Beatriz D'Accorso
- CIHIDECAR-CONICET-UBA, Departamento de Química Orgánica, Facultad de Ciencias Exactas y Naturales; Universidad de Buenos Aires, Pabellón 2, Ciudad Universitaria; 1428 Buenos Aires Argentina
| | - Carlos Enrique Cuevas-Suárez
- Universidad Autónoma del Estado de Hidalgo - Instituto de Ciencias de la Salud, Área Académica de Odontología. Ex Hacienda La Concepción s/n, San Agustín Tlaxiaca; Hidalgo 42160 México
| | - Mirta Liliana Fascio
- CIHIDECAR-CONICET-UBA, Departamento de Química Orgánica, Facultad de Ciencias Exactas y Naturales; Universidad de Buenos Aires, Pabellón 2, Ciudad Universitaria; 1428 Buenos Aires Argentina
| | - Jesús García-Serrano
- Universidad Autónoma del Estado de Hidalgo - Instituto de Ciencias Básicas e Ingeniería, Carretera Pachuca-Tulancingo Km. 4.5 Colonia Carboneras, Mineral de la Reforma; Hidalgo 42183 México
| | - Miriam Martins Alho
- CIHIDECAR-CONICET-UBA, Departamento de Química Orgánica, Facultad de Ciencias Exactas y Naturales; Universidad de Buenos Aires, Pabellón 2, Ciudad Universitaria; 1428 Buenos Aires Argentina
| | - Juan Eliezer Zamarripa-Calderón
- Universidad Autónoma del Estado de Hidalgo - Instituto de Ciencias de la Salud, Área Académica de Odontología. Ex Hacienda La Concepción s/n, San Agustín Tlaxiaca; Hidalgo 42160 México
| |
Collapse
|