1
|
Li J, Hao Y, Wang H, Zhang M, He J, Ni P. Advanced Biomaterials Derived from Functional Polyphosphoesters: Synthesis, Properties, and Biomedical Applications. ACS APPLIED MATERIALS & INTERFACES 2024; 16:51876-51898. [PMID: 39311719 DOI: 10.1021/acsami.4c11899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/04/2024]
Abstract
Polyphosphoesters (PPEs) represent an innovative class of biodegradable polymers, with the phosphate ester serving as the core repeating unit of their polymeric backbone. Recently, biomaterials derived from functionalized PPEs have garnered significant interest in biomedical applications because of their commendable biocompatibility, biodegradability, and the capacity for functional modification. This review commences with a brief overview of synthesis methodologies and the distinctive properties of PPEs, including thermoresponsiveness, degradability, stealth effect, and biocompatibility. Subsequently, the review delves into the latest applications of PPEs-based nanocarriers for drug or gene delivery and PPEs-based polymeric prodrugs and scaffolds in the biomedical field, presenting several illustrative examples for each application. By encapsulating the advancements of recent years, this review aims to offer an enhanced understanding and serve as a reference for the synthesis and biomedical applications of functional PPEs.
Collapse
Affiliation(s)
- Jintao Li
- College of Chemistry, Chemical Engineering and Materials Science, State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application, Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis, Soochow University, Suzhou, Jiangsu 215123, China
| | - Ying Hao
- CAS Key Laboratory of Nano-Bio Interface, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, Jiangsu 215123, China
| | - Hairong Wang
- Children's Hospital of Soochow University, Pediatric Research Institute of Soochow University, Suzhou, Jiangsu 215123, China
| | - Mingzu Zhang
- College of Chemistry, Chemical Engineering and Materials Science, State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application, Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis, Soochow University, Suzhou, Jiangsu 215123, China
| | - Jinlin He
- College of Chemistry, Chemical Engineering and Materials Science, State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application, Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis, Soochow University, Suzhou, Jiangsu 215123, China
| | - Peihong Ni
- College of Chemistry, Chemical Engineering and Materials Science, State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application, Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis, Soochow University, Suzhou, Jiangsu 215123, China
| |
Collapse
|
2
|
Wang S, Wen X, Fan Z, Ding X, Wang Q, Liu Z, Yu W. Research advancements on nerve guide conduits for nerve injury repair. Rev Neurosci 2024; 35:627-637. [PMID: 38517315 DOI: 10.1515/revneuro-2023-0093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 11/19/2023] [Indexed: 03/23/2024]
Abstract
Peripheral nerve injury (PNI) is one of the most serious causes of disability and loss of work capacity of younger individuals. Although PNS has a certain degree of regeneration, there are still challenges like disordered growth, neuroma formation, and incomplete regeneration. Regarding the management of PNI, conventional methods such as surgery, pharmacotherapy, and rehabilitative therapy. Treatment strategies vary depending on the severity of the injury. While for the long nerve defect, autologous nerve grafting is commonly recognized as the preferred surgical approach. Nevertheless, due to lack of donor sources, neurological deficits and the low regeneration efficiency of grafted nerves, nerve guide conduits (NGCs) are recognized as a future promising technology in recent years. This review provides a comprehensive overview of current treatments for PNI, and discusses NGCs from different perspectives, such as material, design, fabrication process, and composite function.
Collapse
Affiliation(s)
- Shoushuai Wang
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| | - Xinggui Wen
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| | - Zheyuan Fan
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| | - Xiangdong Ding
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| | - Qianqian Wang
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| | - Zhongling Liu
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| | - Wei Yu
- China-Japan Union Hospital of Jilin University, 126 Xiantai Street, Changchun City 130033, Jilin Province, China
| |
Collapse
|
3
|
Kesharwani P, Alexander A, Shukla R, Jain S, Bisht A, Kumari K, Verma K, Sharma S. Tissue regeneration properties of hydrogels derived from biological macromolecules: A review. Int J Biol Macromol 2024; 271:132280. [PMID: 38744364 DOI: 10.1016/j.ijbiomac.2024.132280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 05/02/2024] [Accepted: 05/08/2024] [Indexed: 05/16/2024]
Abstract
The successful tissue engineering depends on the development of biologically active scaffolds that possess optimal characteristics to effectively support cellular functions, maintain structural integrity and aid in tissue regeneration. Hydrogels have emerged as promising candidates in tissue regeneration due to their resemblance to the natural extracellular matrix and their ability to support cell survival and proliferation. The integration of hydrogel scaffold into the polymer has a variable impact on the pseudo extracellular environment, fostering cell growth/repair. The modification in size, shape, surface morphology and porosity of hydrogel scaffolds has consequently paved the way for addressing diverse challenges in the tissue engineering process such as tissue architecture, vascularization and simultaneous seeding of multiple cells. The present review provides a comprehensive update on hydrogel production using natural and synthetic biomaterials and their underlying mechanisms. Furthermore, it delves into the application of hydrogel scaffolds in tissue engineering for cardiac tissues, cartilage tissue, adipose tissue, nerve tissue and bone tissue. Besides, the present article also highlights various clinical studies, patents, and the limitations associated with hydrogel-based scaffolds in recent times.
Collapse
Affiliation(s)
- Payal Kesharwani
- Department of Pharmacy, Banasthali Vidyapith, Banasthali, Rajasthan, India; Institute of Pharmacy, Ram-Eesh Institute of Vocational and Technical Education Greater Noida, India
| | - Amit Alexander
- Department of Pharmaceuticals, National Institute of Pharmaceutical Education and Research, Guwahati, Assam, India
| | - Rahul Shukla
- Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER)-Raebareli, Lucknow, Uttar Pradesh, India
| | - Smita Jain
- Department of Pharmacy, Banasthali Vidyapith, Banasthali, Rajasthan, India
| | - Akansha Bisht
- Department of Pharmacy, Banasthali Vidyapith, Banasthali, Rajasthan, India
| | - Kajal Kumari
- Department of Pharmacy, Banasthali Vidyapith, Banasthali, Rajasthan, India
| | - Kanika Verma
- Department of Pharmacy, Banasthali Vidyapith, Banasthali, Rajasthan, India
| | - Swapnil Sharma
- Department of Pharmacy, Banasthali Vidyapith, Banasthali, Rajasthan, India.
| |
Collapse
|
4
|
Fukaura S, Iwasaki Y. Effect of phosphodiester composition in polyphosphoesters on the inhibition of osteoclastic differentiation of murine bone marrow mononuclear cells. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2023; 34:2319-2331. [PMID: 37530459 DOI: 10.1080/09205063.2023.2244737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/22/2023] [Accepted: 07/27/2023] [Indexed: 08/03/2023]
Abstract
Osteoporosis is a common bone disorder characterized by reduced bone density and increased risk of fractures. The modulation of bone cell functions, particularly the inhibition of osteoclastic differentiation, plays a crucial role in osteoporosis treatment. Polyphosphoesters (PPEs) have shown the potential in reducing the function of osteoclast cells, but the effect of their chemical structure on osteoclastic differentiation remains largely unexplored. In this study, we evaluated the effect of PPE's chemical structure on the inhibition of osteoclastic differentiation of murine bone marrow mononuclear cells (BMNCs). PPEs containing phosphotriester and phosphodiester units at varying compositions were synthesized. Cytotoxicity testing confirmed the biocompatibility of the copolymers at concentrations below 0.5 mg/mL. Isolated from long bones, BMNCs were cultured in a differentiation medium supplemented with different PPE concentrations. Osteoclast formation was assessed through tartrate-resistant acid phosphatase and phalloidin staining. A significant decrease in the size of osteoclast cells formed upon BMNC contact with PPEs was observed, with a more pronounced effect observed at higher PPE concentrations. In addition, an increased composition of phosphodiester units in the PPEs yielded a decreased density of differentiated osteoclasts. Furthermore, real-time PCR analysis of major osteoclastic markers provided gene expression data that correlated with microscopic observations, confirming the effect of phosphodiester units in suppressing osteoclast differentiation of BMNCs from the early stages. These findings highlight the potential of PPEs as polymers are capable of modulating bone cell functions through their chemical structures.
Collapse
Affiliation(s)
- Sota Fukaura
- Graduate School of Science and Technology, Kansai University, Osaka, Japan
| | - Yasuhiko Iwasaki
- Department of Chemistry and Materials Engineering, Kansai University, Osaka, Japan
- ORDIST, Kansai University, Osaka, Japan
| |
Collapse
|
5
|
Sasaki R, Watanabe Y, Yamato M, Okamoto T. Tissue-engineered nerve guides with mesenchymal stem cells in the facial nerve regeneration. Neurochem Int 2021; 148:105062. [PMID: 34004239 DOI: 10.1016/j.neuint.2021.105062] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 04/16/2021] [Accepted: 04/26/2021] [Indexed: 12/31/2022]
Abstract
Nerve guides with mesenchymal stem cells have been investigated in the rat facial nerve defect model to promote peripheral nerve regeneration and shorten recovery time to improve patients' quality of life. A 7-mm facial nerve gap experimental rat model is frequently employed in facial nerve regeneration studies. Facial nerve regeneration with nerve guides is evaluated by (1) assessing myelinated fiber counts using toluidine blue staining, (2) immunohistological analysis, (3) determining the g-ratio (axon diameter/total outer diameter) of regenerated nerve on transmission electron microscopic images, (4) retrograde nerve tracing in the facial nucleus, (5) electrophysiological evaluations using compound muscle action potential, and (6) functional evaluations using rat facial palsy scores. Dental pulp and adipose-derived stem cells, easily harvested using a minimally invasive procedure, possess characteristics of mesenchymal tissue lineages and can differentiate into Schwann-like cells. Cultured dental pulp-derived cells can produce neurotrophic factors, including nerve growth factor, brain-derived neurotrophic factor, and glial cell line-derived neurotrophic factor. These neurotrophic factors promote peripheral nerve regeneration and afford protection against facial motor neuron death. Moreover, artificial nerve guides can maneuver axonal regrowth, and dental pulp-derived cells and adipose-derived Schwann cells may supply neurotrophic factors, promoting axonal regeneration. In the present review, the authors discuss facial nerve regeneration using nerve guides with mesenchymal stem cells.
Collapse
Affiliation(s)
- Ryo Sasaki
- Department of Oral and Maxillofacial Surgery, Tokyo Women's Medical University, School of Medicine, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.
| | - Yorikatsu Watanabe
- Department of Plastic and Reconstructive Surgery, Tokyo Metropolitan Police Hospital, 4-22-1 Nakano, Nakano-ku, Tokyo, 164-0001, Japan
| | - Masayuki Yamato
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Toshihiro Okamoto
- Department of Oral and Maxillofacial Surgery, Tokyo Women's Medical University, School of Medicine, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| |
Collapse
|
6
|
Liu H, Zhao Y, Tong J, Shi X, Chen Y, Du Y. Electrofabrication of flexible and mechanically strong tubular chitosan implants for peripheral nerve regeneration. J Mater Chem B 2021; 9:5537-5546. [PMID: 34161401 DOI: 10.1039/d1tb00247c] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The development of peripheral nerve tissue engineering requires a safe and reliable methodology to construct biodegradable conduits. Herein, a new type of chitosan-based nerve-guide hydrogel conduit (CNHC) with enhanced mechanical flexibility in the wet state was fabricated using a one-step electrofabrication technology. The formation of the chitosan conduit is a physical process which can be conducted in a mild water phase without toxic crosslinks. The current density during electrofabrication has a profound effect on the physical and structural properties of the conduits. Cytocompatibility results indicate that the CNHC can promote cell proliferation and adhesion. Functional and histological tests indicate that the CNHC has the ability to guide the growth of axons through the conduit to reach a distal stump, which is closely similar to the autograft group. Overall, the results of this study demonstrate that the CNHCs from electrofabrication have a great potential in peripheral nerve regeneration.
Collapse
Affiliation(s)
- Hongyu Liu
- School of Resource and Environmental Science, Hubei Engineering Center of Natural Polymers-Based Medical Materials, Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Wuhan University, Wuhan 430079, China.
| | - Yanan Zhao
- Department of Biomedical Engineering, School of Basic Medical Sciences, Hubei Province Key Laboratory of Allergy and Immune Related Diseases, Hubei Engineering Center of Natural Polymers-Based Medical Materials, Wuhan University, Wuhan 430071, China.
| | - Jun Tong
- School of Resource and Environmental Science, Hubei Engineering Center of Natural Polymers-Based Medical Materials, Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Wuhan University, Wuhan 430079, China.
| | - Xiaowen Shi
- School of Resource and Environmental Science, Hubei Engineering Center of Natural Polymers-Based Medical Materials, Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Wuhan University, Wuhan 430079, China.
| | - Yun Chen
- Department of Biomedical Engineering, School of Basic Medical Sciences, Hubei Province Key Laboratory of Allergy and Immune Related Diseases, Hubei Engineering Center of Natural Polymers-Based Medical Materials, Wuhan University, Wuhan 430071, China.
| | - Yumin Du
- School of Resource and Environmental Science, Hubei Engineering Center of Natural Polymers-Based Medical Materials, Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Wuhan University, Wuhan 430079, China.
| |
Collapse
|
7
|
Carvalho CR, Chang W, Silva‐Correia J, Reis RL, Oliveira JM, Kohn J. Engineering Silk Fibroin-Based Nerve Conduit with Neurotrophic Factors for Proximal Protection after Peripheral Nerve Injury. Adv Healthc Mater 2021; 10:e2000753. [PMID: 33169544 DOI: 10.1002/adhm.202000753] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 10/15/2020] [Indexed: 12/11/2022]
Abstract
Artificial nerve conduits capable of adequately releasing neurotrophic factors are extensively studied to bridge nerve defects. However, the lack of neurotrophic factors in the proximal area and their visible effects in axonal retrograde transport following nerve injury is one of the factors causing an incomplete nerve regeneration. Herein, an advanced conduit made of silk fibroin is produced, which can incorporate growth factors and promote an effective regeneration after injury. For that, enzymatically crosslinked silk fibroin-based conduits are developed to be used as a platform for the controlled delivery of neurotrophic factors. Nerve growth factor and glial-cell line derived neurotrophic factor (GDNF) are incorporated using two different methodologies: i) crosslinking and ii) absorption method. The release profile is measured by ELISA technique. The bioactivity of the neurotrophic factors is evaluated in vitro by using primary dorsal root ganglia. When implanted in a 10 mm sciatic nerve defect in rats, GDNF-loaded silk fibroin conduits reveal retrograde neuroprotection as compared to autografts and plain silk fibroin conduit. Therefore, the novel design presents a substantial improvement of retrograde trafficking, neurons' protection, and motor nerve reinnervation.
Collapse
Affiliation(s)
- Cristiana R. Carvalho
- 3B's Research Group‐Biomaterials Biodegradables and Biomimetics Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine University of Minho Barco Guimarães 4805‐017 Portugal
| | - Wei Chang
- New Jersey Center for Biomaterials Rutgers The State University of New Jersey Piscataway NJ 08854 USA
| | - Joana Silva‐Correia
- 3B's Research Group‐Biomaterials Biodegradables and Biomimetics Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine University of Minho Barco Guimarães 4805‐017 Portugal
| | - Rui L. Reis
- 3B's Research Group‐Biomaterials Biodegradables and Biomimetics Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine University of Minho Barco Guimarães 4805‐017 Portugal
| | - Joaquim M. Oliveira
- 3B's Research Group‐Biomaterials Biodegradables and Biomimetics Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine University of Minho Barco Guimarães 4805‐017 Portugal
| | - Joachim Kohn
- New Jersey Center for Biomaterials Rutgers The State University of New Jersey Piscataway NJ 08854 USA
| |
Collapse
|
8
|
Fornasari BE, Carta G, Gambarotta G, Raimondo S. Natural-Based Biomaterials for Peripheral Nerve Injury Repair. Front Bioeng Biotechnol 2020; 8:554257. [PMID: 33178670 PMCID: PMC7596179 DOI: 10.3389/fbioe.2020.554257] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 09/23/2020] [Indexed: 01/18/2023] Open
Abstract
Peripheral nerve injury treatment is a relevant problem because of nerve lesion high incidence and because of unsatisfactory regeneration after severe injuries, thus resulting in a reduced patient's life quality. To repair severe nerve injuries characterized by substance loss and to improve the regeneration outcome at both motor and sensory level, different strategies have been investigated. Although autograft remains the gold standard technique, a growing number of research articles concerning nerve conduit use has been reported in the last years. Nerve conduits aim to overcome autograft disadvantages, but they must satisfy some requirements to be suitable for nerve repair. A universal ideal conduit does not exist, since conduit properties have to be evaluated case by case; nevertheless, because of their high biocompatibility and biodegradability, natural-based biomaterials have great potentiality to be used to produce nerve guides. Although they share many characteristics with synthetic biomaterials, natural-based biomaterials should also be preferable because of their extraction sources; indeed, these biomaterials are obtained from different renewable sources or food waste, thus reducing environmental impact and enhancing sustainability in comparison to synthetic ones. This review reports the strengths and weaknesses of natural-based biomaterials used for manufacturing peripheral nerve conduits, analyzing the interactions between natural-based biomaterials and biological environment. Particular attention was paid to the description of the preclinical outcome of nerve regeneration in injury repaired with the different natural-based conduits.
Collapse
Affiliation(s)
- Benedetta E. Fornasari
- Department of Clinical and Biological Sciences, University of Turin, Turin, Italy
- Neuroscience Institute Cavalieri Ottolenghi, University of Turin, Turin, Italy
| | - Giacomo Carta
- Department of Clinical and Biological Sciences, University of Turin, Turin, Italy
- Neuroscience Institute Cavalieri Ottolenghi, University of Turin, Turin, Italy
| | - Giovanna Gambarotta
- Department of Clinical and Biological Sciences, University of Turin, Turin, Italy
- Neuroscience Institute Cavalieri Ottolenghi, University of Turin, Turin, Italy
| | - Stefania Raimondo
- Department of Clinical and Biological Sciences, University of Turin, Turin, Italy
- Neuroscience Institute Cavalieri Ottolenghi, University of Turin, Turin, Italy
| |
Collapse
|
9
|
Strasser P, Teasdale I. Main-Chain Phosphorus-Containing Polymers for Therapeutic Applications. Molecules 2020; 25:E1716. [PMID: 32276516 PMCID: PMC7181247 DOI: 10.3390/molecules25071716] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 04/02/2020] [Accepted: 04/04/2020] [Indexed: 02/07/2023] Open
Abstract
Polymers in which phosphorus is an integral part of the main chain, including polyphosphazenes and polyphosphoesters, have been widely investigated in recent years for their potential in a number of therapeutic applications. Phosphorus, as the central feature of these polymers, endears the chemical functionalization, and in some cases (bio)degradability, to facilitate their use in such therapeutic formulations. Recent advances in the synthetic polymer chemistry have allowed for controlled synthesis methods in order to prepare the complex macromolecular structures required, alongside the control and reproducibility desired for such medical applications. While the main polymer families described herein, polyphosphazenes and polyphosphoesters and their analogues, as well as phosphorus-based dendrimers, have hitherto predominantly been investigated in isolation from one another, this review aims to highlight and bring together some of this research. In doing so, the focus is placed on the essential, and often mutual, design features and structure-property relationships that allow the preparation of such functional materials. The first part of the review details the relevant features of phosphorus-containing polymers in respect to their use in therapeutic applications, while the second part highlights some recent and innovative applications, offering insights into the most state-of-the-art research on phosphorus-based polymers in a therapeutic context.
Collapse
Affiliation(s)
- Paul Strasser
- Institute of Polymer Chemistry, Johannes Kepler University Linz (JKU), Altenberger Straße 69, A-4040 Linz, Austria
| | - Ian Teasdale
- Institute of Polymer Chemistry, Johannes Kepler University Linz (JKU), Altenberger Straße 69, A-4040 Linz, Austria
| |
Collapse
|
10
|
Serbezeanu D, Carja ID, Nicolescu A, Aflori M, Vlad-Bubulac T, Butnaru M, Damian RF, Dunca S, Shova S. Synthesis, crystal structure and biological activity of new phosphoester-p-substituted-methylparabens. J Mol Struct 2019. [DOI: 10.1016/j.molstruc.2019.07.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
11
|
Duffy P, McMahon S, Wang X, Keaveney S, O'Cearbhaill ED, Quintana I, Rodríguez FJ, Wang W. Synthetic bioresorbable poly-α-hydroxyesters as peripheral nerve guidance conduits; a review of material properties, design strategies and their efficacy to date. Biomater Sci 2019; 7:4912-4943. [DOI: 10.1039/c9bm00246d] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Implantable tubular devices known as nerve guidance conduits (NGCs) have drawn considerable interest as an alternative to autografting in the repair of peripheral nerve injuries.
Collapse
Affiliation(s)
- Patrick Duffy
- The Charles Institute of Dermatology
- School of Medicine
- University College Dublin
- Dublin
- Ireland
| | - Seán McMahon
- Ashland Specialties Ireland Ltd
- Synergy Centre
- Dublin
- Ireland
| | - Xi Wang
- The Charles Institute of Dermatology
- School of Medicine
- University College Dublin
- Dublin
- Ireland
| | - Shane Keaveney
- School of Mechanical & Materials Engineering
- UCD Centre for Biomedical Engineering
- UCD Conway Institute of Biomolecular and Biomedical Research
- University College Dublin
- Dublin
| | - Eoin D. O'Cearbhaill
- School of Mechanical & Materials Engineering
- UCD Centre for Biomedical Engineering
- UCD Conway Institute of Biomolecular and Biomedical Research
- University College Dublin
- Dublin
| | - Iban Quintana
- IK4-Tekniker
- Surface Engineering and Materials Science Unit
- Eibar
- Spain
| | | | - Wenxin Wang
- The Charles Institute of Dermatology
- School of Medicine
- University College Dublin
- Dublin
- Ireland
| |
Collapse
|
12
|
Sarker M, Naghieh S, McInnes AD, Schreyer DJ, Chen X. Regeneration of peripheral nerves by nerve guidance conduits: Influence of design, biopolymers, cells, growth factors, and physical stimuli. Prog Neurobiol 2018; 171:125-150. [DOI: 10.1016/j.pneurobio.2018.07.002] [Citation(s) in RCA: 108] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 07/24/2018] [Accepted: 07/26/2018] [Indexed: 01/10/2023]
|
13
|
Maiti B, Díaz Díaz D. 3D Printed Polymeric Hydrogels for Nerve Regeneration. Polymers (Basel) 2018; 10:E1041. [PMID: 30960966 PMCID: PMC6403752 DOI: 10.3390/polym10091041] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2018] [Revised: 09/12/2018] [Accepted: 09/14/2018] [Indexed: 12/23/2022] Open
Abstract
The human nervous system lacks an inherent ability to regenerate its components upon damage or diseased conditions. During the last decade, this has motivated the development of a number of strategies for nerve regeneration. However, most of those approaches have not been used in clinical applications till today. For instance, although biomaterial-based scaffolds have been extensively used for nerve reparation, the lack of more customized structures have hampered their use in vivo. This highlight focuses mainly on how 3D bioprinting technology, using polymeric hydrogels as bio-inks, can be used for the development of new nerve guidance channels or devices for peripheral nerve cell regeneration. In this concise contribution, some of the most recent and representative examples are highlighted to discuss the challenges involved in various aspects of 3D bioprinting for nerve cell regeneration, specifically when using polymeric hydrogels.
Collapse
Affiliation(s)
- Binoy Maiti
- Institute of Organic Chemistry, University of Regensburg, Universitätstr. 31, 93053 Regensburg, Germany.
| | - David Díaz Díaz
- Institute of Organic Chemistry, University of Regensburg, Universitätstr. 31, 93053 Regensburg, Germany.
- Instituto de Química Avanzada de Cataluña-Consejo Superior de Investigaciones Científicas (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain.
| |
Collapse
|
14
|
Davoodi P, Lee LY, Xu Q, Sunil V, Sun Y, Soh S, Wang CH. Drug delivery systems for programmed and on-demand release. Adv Drug Deliv Rev 2018; 132:104-138. [PMID: 30415656 DOI: 10.1016/j.addr.2018.07.002] [Citation(s) in RCA: 188] [Impact Index Per Article: 31.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 05/25/2018] [Accepted: 07/02/2018] [Indexed: 01/06/2023]
Abstract
With the advancement in medical science and understanding the importance of biodistribution and pharmacokinetics of therapeutic agents, modern drug delivery research strives to utilize novel materials and fabrication technologies for the preparation of robust drug delivery systems to combat acute and chronic diseases. Compared to traditional drug carriers, which could only control the release of the agents in a monotonic manner, the new drug carriers are able to provide a precise control over the release time and the quantity of drug introduced into the patient's body. To achieve this goal, scientists have introduced "programmed" and "on-demand" approaches. The former provides delivery systems with a sophisticated architecture to precisely tune the release rate for a definite time period, while the latter includes systems directly controlled by an operator/practitioner, perhaps with a remote device triggering/affecting the implanted or injected drug carrier. Ideally, such devices can determine flexible release pattern and intensify the efficacy of a therapy via controlling time, duration, dosage, and location of drug release in a predictable, repeatable, and reliable manner. This review sheds light on the past and current techniques available for fabricating and remotely controlling drug delivery systems and addresses the application of new technologies (e.g. 3D printing) in this field.
Collapse
|
15
|
Yi S, Xu L, Gu X. Scaffolds for peripheral nerve repair and reconstruction. Exp Neurol 2018; 319:112761. [PMID: 29772248 DOI: 10.1016/j.expneurol.2018.05.016] [Citation(s) in RCA: 88] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Revised: 05/05/2018] [Accepted: 05/13/2018] [Indexed: 12/22/2022]
Abstract
Trauma-associated peripheral nerve defect is a widespread clinical problem. Autologous nerve grafting, the current gold standard technique for the treatment of peripheral nerve injury, has many internal disadvantages. Emerging studies showed that tissue engineered nerve graft is an effective substitute to autologous nerves. Tissue engineered nerve graft is generally composed of neural scaffolds and incorporating cells and molecules. A variety of biomaterials have been used to construct neural scaffolds, the main component of tissue engineered nerve graft. Synthetic polymers (e.g. silicone, polyglycolic acid, and poly(lactic-co-glycolic acid)) and natural materials (e.g. chitosan, silk fibroin, and extracellular matrix components) are commonly used along or together to build neural scaffolds. Many other materials, including the extracellular matrix, glass fabrics, ceramics, and metallic materials, have also been used to construct neural scaffolds. These biomaterials are fabricated to create specific structures and surface features. Seeding supporting cells and/or incorporating neurotrophic factors to neural scaffolds further improve restoration effects. Preliminary studies demonstrate that clinical applications of these neural scaffolds achieve satisfactory functional recovery. Therefore, tissue engineered nerve graft provides a good alternative to autologous nerve graft and represents a promising frontier in neural tissue engineering.
Collapse
Affiliation(s)
- Sheng Yi
- Key laboratory of neuroregeneration of Jiangsu and Ministry of Education, Co-innovation Center of Neuroregeneration, Nantong University, Nantong, Jiangsu, China
| | - Lai Xu
- Key laboratory of neuroregeneration of Jiangsu and Ministry of Education, Co-innovation Center of Neuroregeneration, Nantong University, Nantong, Jiangsu, China
| | - Xiaosong Gu
- Key laboratory of neuroregeneration of Jiangsu and Ministry of Education, Co-innovation Center of Neuroregeneration, Nantong University, Nantong, Jiangsu, China.
| |
Collapse
|
16
|
Chang W, Shah MB, Lee P, Yu X. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration. Acta Biomater 2018; 73:302-311. [PMID: 29702292 DOI: 10.1016/j.actbio.2018.04.046] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 04/10/2018] [Accepted: 04/23/2018] [Indexed: 01/09/2023]
Abstract
Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. STATEMENT OF SIGNIFICANCE We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve. Results from this study can help further optimize tissue engineering strategies for peripheral nerve repair.
Collapse
|
17
|
Gámez E, Goto Y, Nagata K, Iwaki T, Sasaki T, Matsuda T. Photofabricated Gelatin-Based Nerve Conduits: Nerve Tissue Regeneration Potentials. Cell Transplant 2017; 13:549-64. [PMID: 15565867 DOI: 10.3727/000000004783983639] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
There is a strong demand for development of nerve guide conduit with prompt nerve regeneration potential for injury-induced nerve defect. Prior to study on nerve tissue engineering using Schwann cells or nerve stem cells, the effectiveness of photofabricated scaffolds based on photocurable gelatin was examined. This study describes the evaluation of in vivo nerve tissue regeneration potentials of three custom-designed and -fabricated prostheses (inner diameter, 1.2 mm; outer diameter, 2.4 mm; wall thickness, 0.60 mm; and length, 15 mm) made of photocured gelatin: a plain photocured gelatin tube (model I), a photocured gelatin tube packed with bioactive substances (laminin, fibronectin, and nerve growth factor) coimmobilized in a photocured gelatin rod (model II), and a photocured gelatin tube packed with bioactive substances coimmobilized in multifilament fibers (model III). These prostheses were implanted between the proximal and distal stumps 10 mm of the dissected right sciatic nerve of 70 adult male Lewis rats for up to 1 year. The highest regenerative potentials were found using the model III prosthesis, followed by the model II prosthesis. Markedly retarded neural regeneration was observed using the model I prosthesis. These were evaluated from the viewpoints of functional recovery, electrophysiological responses, and tissue morphological regeneration. The significance of the synergistic cooperative functions of multifilaments, which serve as a platform that provides contact guidance to direct longitudinal cell movement and tissue ingrowth and as a cell adhesive matrix with high surface area, and immobilized bioactive substances, which enhance nerve regeneration via biological stimulation, is discussed.
Collapse
Affiliation(s)
- Eduardo Gámez
- Division of Biomedical Engineering, Graduate School of Dental Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-Ku, Fukuoka 812-8582, Japan
| | | | | | | | | | | |
Collapse
|
18
|
Mohamadi F, Ebrahimi-Barough S, Reza Nourani M, Ali Derakhshan M, Goodarzi V, Sadegh Nazockdast M, Farokhi M, Tajerian R, Faridi Majidi R, Ai J. Electrospun nerve guide scaffold of poly(ε-caprolactone)/collagen/nanobioglass: an in vitro
study in peripheral nerve tissue engineering. J Biomed Mater Res A 2017; 105:1960-1972. [DOI: 10.1002/jbm.a.36068] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Revised: 02/23/2017] [Accepted: 03/17/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Forouzan Mohamadi
- Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine; Tehran University of Medical Sciences; Tehran Iran
| | - Somayeh Ebrahimi-Barough
- Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine; Tehran University of Medical Sciences; Tehran Iran
| | - Mohammad Reza Nourani
- Nano Biotechnology Research Center, Baqiyatallah University of Medical Sciences; Tehran Iran
| | - Mohammad Ali Derakhshan
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies; Shiraz University of Medical Sciences; Shiraz Iran
| | - Vahabodin Goodarzi
- Nano Biotechnology Research Center, Baqiyatallah University of Medical Sciences; Tehran Iran
| | | | - Mehdi Farokhi
- National Cell Bank of Iran, Pasteur Institute of Iran; Tehran Iran
| | - Roksana Tajerian
- Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine; Tehran University of Medical Sciences; Tehran Iran
| | - Reza Faridi Majidi
- Department of Nanomedicine, School of Advanced Medical Technologies; Tehran University of Medical Sciences; Tehran Iran
| | - Jafar Ai
- Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine; Tehran University of Medical Sciences; Tehran Iran
| |
Collapse
|
19
|
Busch H, Majumder S, Reiter G, Mecking S. Semicrystalline Long-Chain Polyphosphoesters from Polyesterification. Macromolecules 2017. [DOI: 10.1021/acs.macromol.7b00243] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Hanna Busch
- Department
of Chemistry, University of Konstanz, Universitätsstraße 10, 78457 Konstanz, Germany
| | - Sumit Majumder
- Physikalisches
Institut, Albert-Ludwigs-Universität Freiburg, 79104 Freiburg, Germany
| | - Günter Reiter
- Physikalisches
Institut, Albert-Ludwigs-Universität Freiburg, 79104 Freiburg, Germany
| | - Stefan Mecking
- Department
of Chemistry, University of Konstanz, Universitätsstraße 10, 78457 Konstanz, Germany
| |
Collapse
|
20
|
Adams AM, VanDusen KW, Kostrominova TY, Mertens JP, Larkin LM. Scaffoldless tissue-engineered nerve conduit promotes peripheral nerve regeneration and functional recovery after tibial nerve injury in rats. Neural Regen Res 2017; 12:1529-1537. [PMID: 29090000 PMCID: PMC5649475 DOI: 10.4103/1673-5374.215265] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Damage to peripheral nerve tissue may cause loss of function in both the nerve and the targeted muscles it innervates. This study compared the repair capability of engineered nerve conduit (ENC), engineered fibroblast conduit (EFC), and autograft in a 10-mm tibial nerve gap. ENCs were fabricated utilizing primary fibroblasts and the nerve cells of rats on embryonic day 15 (E15). EFCs were fabricated utilizing primary fibroblasts only. Following a 12-week recovery, nerve repair was assessed by measuring contractile properties in the medial gastrocnemius muscle, distal motor nerve conduction velocity in the lateral gastrocnemius, and histology of muscle and nerve. The autografts, ENCs and EFCs reestablished 96%, 87% and 84% of native distal motor nerve conduction velocity in the lateral gastrocnemius, 100%, 44% and 44% of native specific force of medical gastrocnemius, and 63%, 61% and 67% of native medial gastrocnemius mass, respectively. Histology of the repaired nerve revealed large axons in the autograft, larger but fewer axons in the ENC repair, and many smaller axons in the EFC repair. Muscle histology revealed similar muscle fiber cross-sectional areas among autograft, ENC and EFC repairs. In conclusion, both ENCs and EFCs promoted nerve regeneration in a 10-mm tibial nerve gap repair, suggesting that the E15 rat nerve cells may not be necessary for nerve regeneration, and EFC alone can suffice for peripheral nerve injury repair.
Collapse
Affiliation(s)
- Aaron M Adams
- Department of Molecular and Integrated Physiology, University of Michigan, Ann Arbor, MI, USA
| | - Keith W VanDusen
- Department of Molecular and Integrated Physiology, University of Michigan, Ann Arbor, MI, USA
| | - Tatiana Y Kostrominova
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Northwest, Gary, IN, USA
| | - Jacob P Mertens
- Department of Molecular and Integrated Physiology, University of Michigan, Ann Arbor, MI, USA
| | - Lisa M Larkin
- Department of Molecular and Integrated Physiology, University of Michigan, Ann Arbor, MI, USA.,Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
21
|
Yilmaz ZE, Jérôme C. Polyphosphoesters: New Trends in Synthesis and Drug Delivery Applications. Macromol Biosci 2016; 16:1745-1761. [PMID: 27654308 DOI: 10.1002/mabi.201600269] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 08/18/2016] [Indexed: 11/06/2022]
Abstract
Polymers with repeating phosphoester linkages in the backbone are biodegradable materials that emerge as a promising class of novel biomaterials, especially in the field of drug delivery systems. In contrast to aliphatic polyesters, the pentavalency of the phosphorus atom offers a large diversity of structures and as a consequence a wide range of properties for these materials. In this paper, it is focused on the synthesis of well-defined polyphosphoesters (PPEs) by organocatalyzed ring-opening polymerization, improving the functionalities by combination with click reactions, degradation of functional PPEs and their cytotoxicity, and inputs for applications in drug delivery.
Collapse
Affiliation(s)
- Zeynep Ergul Yilmaz
- Center for Education and Research on Macromolecules (CERM), University of Liège (ULg), CESAM-RU, Sart Tilman, Building B6a, Liège, B-4000, Belgium
| | - Christine Jérôme
- Center for Education and Research on Macromolecules (CERM), University of Liège (ULg), CESAM-RU, Sart Tilman, Building B6a, Liège, B-4000, Belgium
| |
Collapse
|
22
|
Bioengineered silk scaffolds in 3D tissue modeling with focus on mammary tissues. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 59:1168-1180. [DOI: 10.1016/j.msec.2015.10.007] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 09/04/2015] [Accepted: 10/02/2015] [Indexed: 02/07/2023]
|
23
|
Zeynep EY, Antoine D, Brice C, Frank B, Christine J. Double hydrophilic polyphosphoester containing copolymers as efficient templating agents for calcium carbonate microparticles. J Mater Chem B 2015; 3:7227-7236. [PMID: 32262830 DOI: 10.1039/c5tb00887e] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The use of calcium carbonate (CaCO3) microparticles is becoming more and more attractive in many fields especially in biomedical applications in which the fine tuning of the size, morphology and crystalline form of the CaCO3 particles is crucial. Although some structuring compounds, like hyaluronic acid, give satisfying results, the control of the particle structure still has to be improved. To this end, we evaluated the CaCO3 structuring capacity of novel well-defined double hydrophilic block copolymers composed of poly(ethylene oxide) and a polyphosphoester segment with an affinity for calcium like poly(phosphotriester)s bearing pendent carboxylic acids or poly(phosphodiester)s with a negatively charged oxygen atom on each repeating monomer unit. These copolymers were synthesized by a combination of organocatalyzed ring opening polymerization, thiol-yne click chemistry and protection/deprotection methods. The formulation of CaCO3 particles was then performed in the presence of these block copolymers (i) by the classical chemical pathway involving CaCl2 and Na2CO3 and (ii) by a process based on supercritical carbon dioxide (scCO2) technology in which CO3 2- ions are generated in aqueous media and react with Ca2+ ions. Porous CaCO3 microspheres composed of vaterite nanocrystals were obtained. Moreover, a clear dependence of the particle size on the structure of the templating agent was emphasized. In this work, we show that the use of the supercritical process and the substitution of hyaluronic acid for a carboxylic acid containing copolymer decreases the size of the CaCO3 particles by a factor of 6 (∼1.5 μm) while preventing their aggregation.
Collapse
Affiliation(s)
- Ergul Yilmaz Zeynep
- Chemistry Department, Center for Education and Research on Macromolecules (CERM), University of Liège (ULg), Sart Tilman, Building B6a-third floor, Liège, B-4000, Belgium.
| | | | | | | | | |
Collapse
|
24
|
|
25
|
Kappos EA, Engels PE, Tremp M, Meyer zu Schwabedissen M, di Summa P, Fischmann A, von Felten S, Scherberich A, Schaefer DJ, Kalbermatten DF. Peripheral Nerve Repair: Multimodal Comparison of the Long-Term Regenerative Potential of Adipose Tissue-Derived Cells in a Biodegradable Conduit. Stem Cells Dev 2015; 24:2127-41. [PMID: 26134465 DOI: 10.1089/scd.2014.0424] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Tissue engineering is a popular topic in peripheral nerve repair. Combining a nerve conduit with supporting adipose-derived cells could offer an opportunity to prevent time-consuming Schwann cell culture or the use of an autograft with its donor site morbidity and eventually improve clinical outcome. The aim of this study was to provide a broad overview over promising transplantable cells under equal experimental conditions over a long-term period. A 10-mm gap in the sciatic nerve of female Sprague-Dawley rats (7 groups of 7 animals, 8 weeks old) was bridged through a biodegradable fibrin conduit filled with rat adipose-derived stem cells (rASCs), differentiated rASCs (drASCs), human (h)ASCs from the superficial and deep abdominal layer, human stromal vascular fraction (SVF), or rat Schwann cells, respectively. As a control, we resutured a nerve segment as an autograft. Long-term evaluation was carried out after 12 weeks comprising walking track, morphometric, and MRI analyses. The sciatic functional index was calculated. Cross sections of the nerve, proximal, distal, and in between the two sutures, were analyzed for re-/myelination and axon count. Gastrocnemius muscle weights were compared. MRI proved biodegradation of the conduit. Differentiated rat ASCs performed significantly better than undifferentiated rASCs with less muscle atrophy and superior functional results. Superficial hASCs supported regeneration better than deep hASCs, in line with published in vitro data. The best regeneration potential was achieved by the drASC group when compared with other adipose tissue-derived cells. Considering the ease of procedure from harvesting to transplanting, we conclude that comparison of promising cells for nerve regeneration revealed that particularly differentiated ASCs could be a clinically translatable route toward new methods to enhance peripheral nerve repair.
Collapse
Affiliation(s)
- Elisabeth A Kappos
- 1 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Basel , Basel, Switzerland .,2 Department of Neuropathology, Institute of Pathology, University Hospital of Basel , Basel, Switzerland
| | - Patricia E Engels
- 1 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Basel , Basel, Switzerland .,2 Department of Neuropathology, Institute of Pathology, University Hospital of Basel , Basel, Switzerland
| | - Mathias Tremp
- 1 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Basel , Basel, Switzerland .,2 Department of Neuropathology, Institute of Pathology, University Hospital of Basel , Basel, Switzerland
| | - Moritz Meyer zu Schwabedissen
- 1 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Basel , Basel, Switzerland .,2 Department of Neuropathology, Institute of Pathology, University Hospital of Basel , Basel, Switzerland
| | - Pietro di Summa
- 3 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Lausanne , Lausanne, Switzerland
| | - Arne Fischmann
- 4 Division of Neuroradiology, Department of Radiology, University Hospital of Basel , Basel, Switzerland
| | | | - Arnaud Scherberich
- 6 Institute for Surgical Research and Hospital Management, University Hospital of Basel , Basel, Switzerland
| | - Dirk J Schaefer
- 1 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Basel , Basel, Switzerland
| | - Daniel F Kalbermatten
- 1 Department of Plastic, Reconstructive, Aesthetic and Hand Surgery, University Hospital of Basel , Basel, Switzerland .,2 Department of Neuropathology, Institute of Pathology, University Hospital of Basel , Basel, Switzerland
| |
Collapse
|
26
|
Penczek S, Pretula J, Kubisa P, Kaluzynski K, Szymanski R. Reactions of H 3 PO 4 forming polymers. Apparently simple reactions leading to sophisticated structures and applications. Prog Polym Sci 2015. [DOI: 10.1016/j.progpolymsci.2015.01.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Sun B, Jiang XJ, Zhang S, Zhang JC, Li YF, You QZ, Long YZ. Electrospun anisotropic architectures and porous structures for tissue engineering. J Mater Chem B 2015; 3:5389-5410. [DOI: 10.1039/c5tb00472a] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Recent advances in electrospun anisotropic architectures and porous structures, as well as their applications in tissue engineering, are presented.
Collapse
Affiliation(s)
- Bin Sun
- College of Physics
- Qingdao University
- Qingdao 266071
- P. R. China
- Key Laboratory of Photonics Materials and Technology in Universities of Shandong (Qingdao University)
| | - Xue-Jun Jiang
- College of Physics
- Qingdao University
- Qingdao 266071
- P. R. China
- Key Laboratory of Photonics Materials and Technology in Universities of Shandong (Qingdao University)
| | - Shuchao Zhang
- Department of Blood Transfusion
- the Affiliated Hospital of Qingdao University
- Qingdao
- P. R. China
- Department of Immunology
| | - Jun-Cheng Zhang
- College of Physics
- Qingdao University
- Qingdao 266071
- P. R. China
- Key Laboratory of Photonics Materials and Technology in Universities of Shandong (Qingdao University)
| | - Yi-Feng Li
- College of Physics
- Qingdao University
- Qingdao 266071
- P. R. China
| | - Qin-Zhong You
- College of Physics
- Qingdao University
- Qingdao 266071
- P. R. China
| | - Yun-Ze Long
- College of Physics
- Qingdao University
- Qingdao 266071
- P. R. China
- Key Laboratory of Photonics Materials and Technology in Universities of Shandong (Qingdao University)
| |
Collapse
|
28
|
Chang W, DeVince J, Green G, Shah MB, Johns MS, Meng Y, Yu X. The development of a normalization method for comparing nerve regeneration effectiveness among different graft types. J Peripher Nerv Syst 2014; 18:297-305. [PMID: 24118184 DOI: 10.1111/jns5.12043] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 06/05/2013] [Accepted: 09/30/2013] [Indexed: 01/02/2023]
Abstract
The inability to compare directly different nerve grafts has been a significant factor hindering the advance of nerve graft development. Due to the abundance of variables that exist in nerve graft construction and multiple assessment types, there has been limited success in comparing nerve graft effectiveness among experiments. Using mathematical techniques on nerve conduction velocity (NCV) autograft data, a normalization function was empirically derived that normalizes differences in gap lengths. Further analysis allowed for the development of the relative regeneration ratio (RRR). The RRR function allows researchers to directly compare nerve graft results based on the NCV data from their respective studies as long as the data was collected at the same post-operation time. This function also allows for comparisons between grafts tested at different gap lengths. Initial testing of this RRR function provided confidence that the function is accurate for a continuum of gap lengths and different nerve graft types.
Collapse
Affiliation(s)
- Wei Chang
- Department of Chemistry, Chemical Biology and Biomedical Engineering
| | | | | | | | | | | | | |
Collapse
|
29
|
Liu BS, Huang TB, Chan SC. Roles of reinforced nerve conduits and low-level laser phototherapy for long gap peripheral nerve repair. Neural Regen Res 2014; 9:1180-2. [PMID: 25206779 PMCID: PMC4146286 DOI: 10.4103/1673-5374.135323] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/28/2014] [Indexed: 11/09/2022] Open
Affiliation(s)
- Bai-Shuan Liu
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan, China
| | - Tsung-Bin Huang
- Department of Bioscience Technology, Chang Jung Christian University, Tainan, Taiwan, China
| | - Shiuh-Chuan Chan
- Graduate Institute of Pharmaceutical Science and Technology, Central Taiwan University of Science and Technology, Taichung, Taiwan, China
| |
Collapse
|
30
|
Abstract
Disease and injury have resulted in a large, unmet need for functional tissue replacements. Polymeric scaffolds can be used to deliver cells and bioactive signals to address this need for regenerating damaged tissue. Phosphorous-containing polymers have been implemented to improve and accelerate the formation of native tissue both by mimicking the native role of phosphorous groups in the body and by attachment of other bioactive molecules. This manuscript reviews the synthesis, properties, and performance of phosphorous-containing polymers that can be useful in regenerative medicine applications.
Collapse
Affiliation(s)
- Brendan M. Watson
- Department of Bioengineering, Rice University 6500 Main Street, Houston, Texas 77030, USA
| | - F. Kurtis Kasper
- Department of Bioengineering, Rice University 6500 Main Street, Houston, Texas 77030, USA
| | - Antonios G. Mikos
- Department of Bioengineering, Rice University 6500 Main Street, Houston, Texas 77030, USA
| |
Collapse
|
31
|
Tran RT, Choy WM, Cao H, Qattan I, Chiao JC, Ip WY, Yeung KWK, Yang J. Fabrication and characterization of biomimetic multichanneled crosslinked-urethane-doped polyester tissue engineered nerve guides. J Biomed Mater Res A 2013; 102:2793-804. [PMID: 24115502 DOI: 10.1002/jbm.a.34952] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Revised: 09/05/2013] [Accepted: 09/06/2013] [Indexed: 01/06/2023]
Abstract
Biomimetic scaffolds that replicate the native architecture and mechanical properties of target tissues have been recently shown to be a very promising strategy to guide cellular growth and facilitate tissue regeneration. In this study, porous, soft, and elastic crosslinked urethane-doped polyester (CUPE) tissue engineered nerve guides were fabricated with multiple longitudinally oriented channels and an external non-porous sheath to mimic the native endoneurial microtubular and epineurium structure, respectively. The fabrication technique described herein is highly adaptable and allows for fine control over the resulting nerve guide architecture in terms of channel number, channel diameter, porosity, and mechanical properties. Biomimetic multichanneled CUPE guides were fabricated with various channel numbers and displayed an ultimate peak stress of 1.38 ± 0.22 MPa with a corresponding elongation at break of 122.76 ± 42.17%, which were comparable to that of native nerve tissue. The CUPE nerve guides were also evaluated in vivo for the repair of a 1 cm rat sciatic nerve defect. Although histological evaluations revealed collapse of the inner structure from CUPE TENGs, the CUPE nerve guides displayed fiber populations and densities comparable with nerve autograft controls after 8 weeks of implantation. These studies are the first report of a CUPE-based biomimetic multichanneled nerve guide and warrant future studies towards optimization of the channel geometry for use in neural tissue engineering.
Collapse
Affiliation(s)
- Richard T Tran
- Department of Bioengineering, Materials Research Institute, The Huck Institutes of the Life Sciences, The Pennsylvania State University, University Park, Pennsylvania, 16802
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Hao Y, He J, Zhang M, Tao Y, Liu J, Ni P. Synthesis and characterization of novel brush copolymers with biodegradable polyphosphoester side chains for gene delivery. ACTA ACUST UNITED AC 2013. [DOI: 10.1002/pola.26617] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
33
|
Marsico F, Wagner M, Landfester K, Wurm FR. Unsaturated Polyphosphoesters via Acyclic Diene Metathesis Polymerization. Macromolecules 2012. [DOI: 10.1021/ma301508s] [Citation(s) in RCA: 77] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Filippo Marsico
- Max Planck Institut für Polymerforschung, Ackermannweg
10, 55128 Mainz, Germany
| | - Manfred Wagner
- Max Planck Institut für Polymerforschung, Ackermannweg
10, 55128 Mainz, Germany
| | | | - Frederik R. Wurm
- Max Planck Institut für Polymerforschung, Ackermannweg
10, 55128 Mainz, Germany
| |
Collapse
|
34
|
Mao S, Guo C, Shi Y, Li LC. Recent advances in polymeric microspheres for parenteral drug delivery – part 1. Expert Opin Drug Deliv 2012; 9:1161-76. [DOI: 10.1517/17425247.2012.709844] [Citation(s) in RCA: 67] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
35
|
Transferrin-conjugated polyphosphoester hybrid micelle loading paclitaxel for brain-targeting delivery: Synthesis, preparation and in vivo evaluation. J Control Release 2012; 159:429-34. [DOI: 10.1016/j.jconrel.2012.01.031] [Citation(s) in RCA: 116] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2011] [Revised: 12/19/2011] [Accepted: 01/22/2012] [Indexed: 12/20/2022]
|
36
|
FDA approved guidance conduits and wraps for peripheral nerve injury: a review of materials and efficacy. Injury 2012; 43:553-72. [PMID: 21269624 DOI: 10.1016/j.injury.2010.12.030] [Citation(s) in RCA: 488] [Impact Index Per Article: 40.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2010] [Accepted: 12/27/2010] [Indexed: 02/02/2023]
Abstract
Several nerve guidance conduits (NGCs) and nerve protectant wraps are approved by the US Food and Drug Administration (FDA) for clinical use in peripheral nerve repair. These devices cover a wide range of natural and synthetic materials, which may or may not be resorbable. This review consolidates the data pertaining to all FDA approved materials into a single reference, which emphasizes material composition alongside pre-clinical and clinical safety and efficacy (where possible). This article also summarizes the key advantages and limitations for each material as noted in the literature (with respect to the indication considered). In this context, this review provides a comprehensive reference for clinicians which may facilitate optimal material/device selection for peripheral nerve repair. For materials scientists, this review highlights predicate devices and evaluation methodologies, offering an insight into current deficiencies associated with state-of-the-art materials and may help direct new technology developments and evaluation methodologies thereof.
Collapse
|
37
|
Liu Q, Jiang L, Shi R, Zhang L. Synthesis, preparation, in vitro degradation, and application of novel degradable bioelastomers—A review. Prog Polym Sci 2012. [DOI: 10.1016/j.progpolymsci.2011.11.001] [Citation(s) in RCA: 127] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
38
|
Lu MC, Hsiang SW, Lai TY, Yao CH, Lin LY, Chen YS. Influence of cross-linking degree of a biodegradable genipin-cross-linked gelatin guide on peripheral nerve regeneration. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 18:843-63. [PMID: 17688744 DOI: 10.1163/156856207781367747] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
We evaluated peripheral nerve regeneration using biodegradable genipin-cross-linked gelatin nerve conduits (GGCs) with three different cross-linking degrees, 24, 36 and 51%. Biocompatibility and biodegradability of the GGC and its efficiency as a guidance channel were examined based on the repair process of a 10-mm gap in the rat sciatic nerve. From this pilot study we concluded that GGCs with a mean cross-linking degree of 36% can ensure nerve regeneration with a more mature structure, as demonstrated by better developed epineural and perineural organisation and axonal development, as well as better-recovered electrophysiology with a relatively positive sciatic functional index and a shorter latency of the muscle action potential curve. Regenerated nerves in the GGCs with mean cross-linking degrees of 24 and 51% were less favourable, due to irritation caused by degradation material and compression by the remaining tube walls, respectively.
Collapse
Affiliation(s)
- Ming-Chin Lu
- School of Post-Baccalaureat Chinese Medicine, China Medical University, Taichung, Taiwan
| | | | | | | | | | | |
Collapse
|
39
|
Zhou ZH, Liu XP, Liu LH. Preparation and Biocompatibility of Poly(L-lactide-co-glycolide) Scaffold Materials for Nerve Conduits. Des Monomers Polym 2012. [DOI: 10.1163/156855508x328149] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Z. H. Zhou
- a College of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, P. R. China
| | - X. P. Liu
- b College of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, P. R. China
| | - L. H. Liu
- c College of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, P. R. China
| |
Collapse
|
40
|
Toll EC, Seifalian AM, Birchall MA. The role of immunophilin ligands in nerve regeneration. Regen Med 2012; 6:635-52. [PMID: 21916598 DOI: 10.2217/rme.11.43] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Tacrolimus (FK506) is a widely used immunosuppressant in organ transplantation. However, it also has neurotrophic activity that occurs independently of its immunosuppressive effects. Other neurotrophic immunophilin ligands that do not exhibit immunosuppression have subsequently been developed and studied in various models of nerve injury. This article reviews the literature on the use of tacrolimus and other immunophilin ligands in peripheral nerve, cranial nerve and spinal cord injuries. The most convincing evidence of enhanced nerve regeneration is seen with systemic administration of tacrolimus in peripheral nerve injury, although clinical use is limited due to its immunosuppressive side effects. Local tacrolimus delivery to the site of nerve repair in peripheral and cranial nerve injury is less effective but requires further investigation. Tacrolimus can enhance outcomes in nerve allograft reconstruction and accelerates reinnervation of complex functional allograft transplants. Other non-immunosuppressive immunophilins ligands such as V-10367 and FK1706 demonstrate enhanced neuroregeneration in the peripheral nervous system and CNS. Mixed results are found in the application of immunophilin ligands to treat spinal cord injury. Immunophilin ligands have great potential in the treatment of nerve injury, but further preclinical studies are necessary to permit translation into clinical trials.
Collapse
Affiliation(s)
- Edward C Toll
- Division of Surgery and Interventional Science, University College London, UK.
| | | | | |
Collapse
|
41
|
Oussadi K, Montembault V, Belbachir M, Fontaine L. Ring-opening bulk polymerization of five- and six-membered cyclic phosphonates using maghnite, a nontoxic proton exchanged montmorillonite clay. J Appl Polym Sci 2011. [DOI: 10.1002/app.34193] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
42
|
Monge S, Canniccioni B, Graillot A, Robin JJ. Phosphorus-Containing Polymers: A Great Opportunity for the Biomedical Field. Biomacromolecules 2011; 12:1973-82. [DOI: 10.1021/bm2004803] [Citation(s) in RCA: 243] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Sophie Monge
- Institut Charles Gerhardt Montpellier UMR5253 CNRS-UM2-ENSCM-UM1 - Equipe Ingénierie et Architectures Macromoléculaires, Université Montpellier II cc1702, Place Eugène Bataillon 34095 Montpellier Cedex 5
| | - Benjamin Canniccioni
- Institut Charles Gerhardt Montpellier UMR5253 CNRS-UM2-ENSCM-UM1 - Equipe Ingénierie et Architectures Macromoléculaires, Université Montpellier II cc1702, Place Eugène Bataillon 34095 Montpellier Cedex 5
| | - Alain Graillot
- Institut Charles Gerhardt Montpellier UMR5253 CNRS-UM2-ENSCM-UM1 - Equipe Ingénierie et Architectures Macromoléculaires, Université Montpellier II cc1702, Place Eugène Bataillon 34095 Montpellier Cedex 5
| | - Jean-Jacques Robin
- Institut Charles Gerhardt Montpellier UMR5253 CNRS-UM2-ENSCM-UM1 - Equipe Ingénierie et Architectures Macromoléculaires, Université Montpellier II cc1702, Place Eugène Bataillon 34095 Montpellier Cedex 5
| |
Collapse
|
43
|
Subramanian A, Krishnan UM, Sethuraman S. Fabrication of uniaxially aligned 3D electrospun scaffolds for neural regeneration. Biomed Mater 2011; 6:025004. [DOI: 10.1088/1748-6041/6/2/025004] [Citation(s) in RCA: 118] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
44
|
Yang YC, Shen CC, Huang TB, Chang SH, Cheng HC, Liu BS. Characteristics and biocompatibility of a biodegradable genipin-cross-linked gelatin/β-tricalcium phosphate reinforced nerve guide conduit. J Biomed Mater Res B Appl Biomater 2011; 95:207-17. [PMID: 20737555 DOI: 10.1002/jbm.b.31705] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
To modulate the mechanical properties of nerve guide conduit for surgical manipulation, this study develops a biodegradable composite containing genipin cross-linked gelatin annexed with β-tricalcium phosphate ceramic particles as a nerve guide material. The conduit was dark bluish and round with a rough and compact outer surface compared to the genipin cross-linked gelatin conduit (without β-tricalcium phosphate). Water uptake and swelling tests indicate that the conduit noticeably increases the stability in water, and the hydrated conduit does not collapse and stenose. The conduit has a sufficiently high level of mechanical properties to serve as a nerve guide. After subcutaneous implantation on the dorsal side of a rat, the degraded conduit only evokes a mild tissue response, and the formation of a very thin fibrous capsule surrounds the conduit. This paper assesses the effectiveness of the conduit as a guidance channel when we use it to repair a 10 mm gap in the rat's sciatic nerve. The experimental results show no gross inflammatory reactions of the peripheral nerve tissues at the implantation site in either group. In overall gross examination, the diameter of the intratubular and newly formed nerve fibers in the conduits exceeds that of the silicone tubes during the implantation period. The quantitative results indicate the superiority of the conduits over the silicone tubes. This study microscopically observes the nerve regeneration in the tissue section at the middle region of all implanted conduits. Therefore, the histomorphometric assessment demonstrates that the conduit could be a candidate for peripheral nerve repair.
Collapse
Affiliation(s)
- Yi-Chin Yang
- Department of Life Sciences, National Chung Hsing University, Taichung, Taiwan, Republic of China
| | | | | | | | | | | |
Collapse
|
45
|
Mey J, Brook G, Hodde D, Kriebel A. Electrospun Fibers as Substrates for Peripheral Nerve Regeneration. BIOMEDICAL APPLICATIONS OF POLYMERIC NANOFIBERS 2011. [DOI: 10.1007/12_2011_122] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
46
|
|
47
|
Chen C, Liu G, Liu X, Pang S, Zhu C, Lv L, Ji J. Photo-responsive, biocompatible polymeric micelles self-assembled from hyperbranched polyphosphate-based polymers. Polym Chem 2011. [DOI: 10.1039/c1py00094b] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
48
|
Gu X, Ding F, Yang Y, Liu J. Construction of tissue engineered nerve grafts and their application in peripheral nerve regeneration. Prog Neurobiol 2010; 93:204-30. [PMID: 21130136 DOI: 10.1016/j.pneurobio.2010.11.002] [Citation(s) in RCA: 419] [Impact Index Per Article: 29.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2010] [Revised: 11/02/2010] [Accepted: 11/23/2010] [Indexed: 01/01/2023]
Abstract
Surgical repair of severe peripheral nerve injuries represents not only a pressing medical need, but also a great clinical challenge. Autologous nerve grafting remains a golden standard for bridging an extended gap in transected nerves. The formidable limitations related to this approach, however, have evoked the development of tissue engineered nerve grafts as a promising alternative to autologous nerve grafts. A tissue engineered nerve graft is typically constructed through a combination of a neural scaffold and a variety of cellular and molecular components. The initial and basic structure of the neural scaffold that serves to provide mechanical guidance and optimal environment for nerve regeneration was a single hollow nerve guidance conduit. Later there have been several improvements to the basic structure, especially introduction of physical fillers into the lumen of a hollow nerve guidance conduit. Up to now, a diverse array of biomaterials, either of natural or of synthetic origin, together with well-defined fabrication techniques, has been employed to prepare neural scaffolds with different structures and properties. Meanwhile different types of support cells and/or growth factors have been incorporated into the neural scaffold, producing unique biochemical effects on nerve regeneration and function restoration. This review attempts to summarize different nerve grafts used for peripheral nerve repair, to highlight various basic components of tissue engineered nerve grafts in terms of their structures, features, and nerve regeneration-promoting actions, and finally to discuss current clinical applications and future perspectives of tissue engineered nerve grafts.
Collapse
Affiliation(s)
- Xiaosong Gu
- Jiangsu Key Laboratory of Neuroregeneration, Nantong University, 19 Qixiu Road, Nantong, JS 226001, PR China.
| | | | | | | |
Collapse
|
49
|
Yang YC, Shen CC, Cheng HC, Liu BS. Sciatic nerve repair by reinforced nerve conduits made of gelatin-tricalcium phosphate composites. J Biomed Mater Res A 2010; 96:288-300. [PMID: 21171148 DOI: 10.1002/jbm.a.32973] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2010] [Accepted: 09/02/2010] [Indexed: 11/07/2022]
Abstract
This study proposes a biodegradable GGT composite nerve guide conduit containing genipin-cross-linked gelatin and tricalcium phosphate (TCP) ceramic particles in peripheral nerve regeneration. The proposed genipin-cross-linked gelatin annexed with TCP ceramic particles (GGT) conduit was dark bluish and round with a rough and compact surface. Water uptake and swelling tests indicated that the hydrated GGT conduit exhibited increased stability with not collapsing or stenosis. The GGT conduit had higher mechanical properties than the genipin-cross-linked gelatin without TCP ceramic particles (GG) conduit and served as a better nerve guide conduit. Cytotoxicity tests revealed that the GGT conduit was not toxic and that it promoted the viability and growth of neural stem cells. The experiments in this study confirmed the effectiveness of the GGT conduit as a guidance channel for repairing a 10-mm gap in rat sciatic nerve. Walking track analysis showed a significantly higher sciatic function index score and better toe spreading development in the GGT group than in the silicone group 8 weeks after implantation. Gross examination revealed that the diameter of the intratubular newly formed nerve fibers in GGT conduits exceeded those in silicone tubes after the implantation period. Histological observations revealed that the morphology and distribution patterns of nerve fibers in the GGT conduits at 8 weeks after implantation were similar to those of normal nerves. The quantitative results indicated the superiority of the conduits over the silicone tubes. Motor functional and histomorphometric assessments demonstrate that the proposed GGT conduit is a suitable candidate for peripheral nerve repair.
Collapse
Affiliation(s)
- Yi-Chin Yang
- Department of Life Sciences, National Chung Hsing University, Taichung, Taiwan, Republic of China
| | | | | | | |
Collapse
|
50
|
Liu J, Huang W, Pang Y, Zhu X, Zhou Y, Yan D. Hyperbranched polyphosphates for drug delivery application: design, synthesis, and in vitro evaluation. Biomacromolecules 2010; 11:1564-70. [PMID: 20364861 DOI: 10.1021/bm100188h] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A water-soluble hyperbranched polyphosphate (HPHEEP) was synthesized through the self-condensation ring-opening polymerization (SCROP) of 2-(2-hydroxyethoxy)ethoxy-2-oxo-1,3,2-dioxaphospholane (HEEP), and its suitability as a drug carrier was then evaluated in vitro. Methyl tetrazolium (MTT) and live/dead staining assays indicated that HPHEEP had excellent biocompatibility against COS-7 cells. The good biodegradability of HPHEEP was observed by NMR analysis, and the degradation products were nontoxic to COS-7 cells. Flow cytometry and confocal laser scanning microscopy analyses suggested that HPHEEP could be easily internalized by vivid cells and preferentially accumulated in the perinuclear region. Furthermore, a hydrophobic anticancer drug, chlorambucil, was used as a model drug and covalently bound to HPHEEP. The chlorambucil dose of the conjugate and free drug required for 50% cellular growth inhibition were 75 and 50 microg/mL, respectively, according to MTT assay against an MCF-7 breast cancer cell line in vitro. This high activity of the conjugate may be attributed to the biodegradability of HPHEEP so as to release the chlorambucil in cells. Therefore, on the basis of its biocompatibility and biodegradability, HPHEEP could provide a charming opportunity to design some excellent drug delivery systems for therapeutic applications.
Collapse
Affiliation(s)
- Jinyao Liu
- School of Chemistry and Chemical Engineering, State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, 200240, PR China
| | | | | | | | | | | |
Collapse
|