1
|
Ferrari G, Silveira da Silva L, Cerruti R, Gindri IDM, Salmoria GV, de Mello Roesler CR. Development and characterization of 3D printed ethylene vinyl acetate (EVA) as drug delivery device for the treatment of overactive bladder. Drug Dev Ind Pharm 2024; 50:285-296. [PMID: 38486377 DOI: 10.1080/03639045.2024.2311177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 01/23/2024] [Indexed: 04/20/2024]
Abstract
The overactive bladder is a condition characterized by a sudden urge to urinate, even with small volumes of urine present in the bladder. The current treatments available for this pathology consist on conservative approaches and the continuous administration of drugs, which when made by conventional methods has limitations related to the first pass metabolism, bioavailability, severe side effects, and low patient adherence to treatments, ultimately leading to low effectiveness. Within this context, the present work proposes the design, manufacture, and characterization of an intravesical implant for the treatment of overactive bladder pathology, using EVA copolymer as a matrix and oxybutynin as a drug. The fabrication of devices through two manufacturing techniques (extrusion and additive manufacturing by fused filament fabrication, FFF) and the evaluation of the implants through characterization tests was proposed. The usability and functionality were evaluated through simulated insertion of the device/prototype in a bladder model through catheter insertion tests. The safety and effectiveness of the devices was investigated from mechanical testing as well as drug release assays. Drug release assays presented a burst release in the first 24 h, followed by a release of 1.8 and 2.8 mg/d, totalizing 32 d. Mechanical tests demonstrated an increase in the stiffness of the specimens due to the addition of the drug, showing a change in maximum stress and strain at break. The released dose was higher than that usually presented when considering the oral administration route, showing the optimization of the development of this implant has the potential to improve the quality of life of patients with overactive bladder.
Collapse
Affiliation(s)
- Gustavo Ferrari
- Iaso Biodelivery Fabricação de Dispositivos com Liberação de Fármacos LTDA, Florianópolis, Santa Catarina, Brazil
- Biomechanical Engineering Laboratory, University Hospital & Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | - Loise Silveira da Silva
- Iaso Biodelivery Fabricação de Dispositivos com Liberação de Fármacos LTDA, Florianópolis, Santa Catarina, Brazil
- Biomechanical Engineering Laboratory, University Hospital & Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | - Renata Cerruti
- Iaso Biodelivery Fabricação de Dispositivos com Liberação de Fármacos LTDA, Florianópolis, Santa Catarina, Brazil
| | - Izabelle de Mello Gindri
- Iaso Biodelivery Fabricação de Dispositivos com Liberação de Fármacos LTDA, Florianópolis, Santa Catarina, Brazil
- Bio meds Pharmaceutica LTDA, Florianópolis, Santa Catarina, Brazil
| | - Gean Vitor Salmoria
- Biomechanical Engineering Laboratory, University Hospital & Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
- NIMMA, Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| | - Carlos Rodrigo de Mello Roesler
- Biomechanical Engineering Laboratory, University Hospital & Department of Mechanical Engineering, Federal University of Santa Catarina (UFSC), Florianópolis, Santa Catarina, Brazil
| |
Collapse
|
2
|
Shastri DH, Silva AC, Almeida H. Ocular Delivery of Therapeutic Proteins: A Review. Pharmaceutics 2023; 15:pharmaceutics15010205. [PMID: 36678834 PMCID: PMC9864358 DOI: 10.3390/pharmaceutics15010205] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 12/25/2022] [Accepted: 01/04/2023] [Indexed: 01/11/2023] Open
Abstract
Therapeutic proteins, including monoclonal antibodies, single chain variable fragment (ScFv), crystallizable fragment (Fc), and fragment antigen binding (Fab), have accounted for one-third of all drugs on the world market. In particular, these medicines have been widely used in ocular therapies in the treatment of various diseases, such as age-related macular degeneration, corneal neovascularization, diabetic retinopathy, and retinal vein occlusion. However, the formulation of these biomacromolecules is challenging due to their high molecular weight, complex structure, instability, short half-life, enzymatic degradation, and immunogenicity, which leads to the failure of therapies. Various efforts have been made to overcome the ocular barriers, providing effective delivery of therapeutic proteins, such as altering the protein structure or including it in new delivery systems. These strategies are not only cost-effective and beneficial to patients but have also been shown to allow for fewer drug side effects. In this review, we discuss several factors that affect the design of formulations and the delivery of therapeutic proteins to ocular tissues, such as the use of injectable micro/nanocarriers, hydrogels, implants, iontophoresis, cell-based therapy, and combination techniques. In addition, other approaches are briefly discussed, related to the structural modification of these proteins, improving their bioavailability in the posterior segments of the eye without affecting their stability. Future research should be conducted toward the development of more effective, stable, noninvasive, and cost-effective formulations for the ocular delivery of therapeutic proteins. In addition, more insights into preclinical to clinical translation are needed.
Collapse
Affiliation(s)
- Divyesh H. Shastri
- Department of Pharmaceutics & Pharmaceutical Technology, K.B. Institute of Pharmaceutical Education and Research, Kadi Sarva Vishwavidyalaya, Sarva Vidyalaya Kelavani Mandal, Gandhinagar 382016, India
- Correspondence:
| | - Ana Catarina Silva
- FP-I3ID (Instituto de Investigação, Inovação e Desenvolvimento), FP-BHS (Biomedical and Health Sciences Research Unit), Faculty of Health Sciences, University Fernando Pessoa, 4249-004 Porto, Portugal
- UCIBIO (Research Unit on Applied Molecular Biosciences), REQUIMTE (Rede de Química e Tecnologia), MEDTECH (Medicines and Healthcare Products), Laboratory of Pharmaceutical Technology, Department of Drug Sciences, Faculty of Pharmacy, University of Porto, 4050-313 Porto, Portugal
- Associate Laboratory i4HB-Institute for Health and Bioeconomy, Faculty of Pharmacy, University of Porto, 4050-313 Porto, Portugal
| | - Hugo Almeida
- UCIBIO (Research Unit on Applied Molecular Biosciences), REQUIMTE (Rede de Química e Tecnologia), MEDTECH (Medicines and Healthcare Products), Laboratory of Pharmaceutical Technology, Department of Drug Sciences, Faculty of Pharmacy, University of Porto, 4050-313 Porto, Portugal
- Associate Laboratory i4HB-Institute for Health and Bioeconomy, Faculty of Pharmacy, University of Porto, 4050-313 Porto, Portugal
- Mesosystem Investigação & Investimentos by Spinpark, Barco, 4805-017 Guimarães, Portugal
| |
Collapse
|
3
|
Maturavongsadit P, Paravyan G, Kovarova M, Garcia JV, Benhabbour SR. A new engineering process of biodegradable polymeric solid implants for ultra-long-acting drug delivery. Int J Pharm X 2021; 3:100068. [PMID: 33392498 PMCID: PMC7773589 DOI: 10.1016/j.ijpx.2020.100068] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
We present a long-acting (LA) biodegradable polymeric solid implant (PSI) fabricated using a new process combining in-situ phase inversion and compression. This robust process allows fabrication of solid implants that can have different shapes and sizes, accommodate high drug payloads, and provide sustained drug release over several months. Herein the integrase inhibitor dolutegravir (DTG) was used to develop PSIs for HIV prevention. PSIs were fabricated using a three-step process by (a) phase inversion of DTG-loaded polymer solution to form an initial in-situ forming implant in an aqueous solution, (b) micronization of dried DTG-loaded solid implants, and (c) compression of the micronized DTG-loaded solid implants to form the PSI. High drug loading (up to 85 wt%) was achieved in the PSIs. DTG exhibited minimum burst release in the first 24 h (<6%) and sustained release kinetics over 6 months. The release kinetics of DTG can be fine-tuned by varying drug-loading concentration, the ratio of polymer (poly(lactic-co-glycolic acid), PLGA) to solvent (N-methyl-2-pyrrolidone, NMP) and polymer (PLGA) molecular weight in the precursor solution. The physical/chemical properties of DTG were retained post-storage under accelerated storage conditions (40 °C/75% relative humidity) for 6 months. The versatility of this technology makes it an attractive drug delivery platform for HIV prevention applications.
Collapse
Affiliation(s)
- Panita Maturavongsadit
- Joint Department of Biomedical Engineering, North Carolina State University and The University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Gayane Paravyan
- Joint Department of Biomedical Engineering, North Carolina State University and The University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Martina Kovarova
- International Center for the Advancement of Translational Science, USA
- Division of Infectious Diseases, Center for Aids Research, School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - J. Victor Garcia
- International Center for the Advancement of Translational Science, USA
- Division of Infectious Diseases, Center for Aids Research, School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - S. Rahima Benhabbour
- Joint Department of Biomedical Engineering, North Carolina State University and The University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
- Division of Pharmacoengineering and Molecular Pharmaceutics, UNC Eshelman School of Pharmacy, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| |
Collapse
|
4
|
Mohtashami Z, Javar HA, Tehrani MR, Esfahani MR, Roohipour R, Aghajanpour L, Amoli FA, Vakilinezhad MA, Dorkoosh FA. Fabrication, Optimization, and In Vitro and In Vivo Characterization of Intra-vitreal Implant of Budesonide Generally Made of PHBV. AAPS PharmSciTech 2020; 21:314. [PMID: 33165678 DOI: 10.1208/s12249-020-01828-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/22/2020] [Indexed: 12/19/2022] Open
Abstract
Drug delivery to vitreous in comparison with drug delivery to the other parts of the eye is complicated and challenging due to the existence of various anatomical and physiological barriers. Developing injectable intra-vitreal implant could be beneficial in this regard. Herein, poly(hydroxybutyrate-co-valerate) (PHBV) implants were fabricated and optimized using response surface method for budesonide (BZ) delivery. The acquired implants were characterized in regard to the stability of the ingredients during fabrication process, drug loading amount, and drug release pattern (in PBS-HA-A and in vitreous medium). According to this research and statistical analysis performed, first HV% (hydroxyvalerate) then molecular weight and ratio of PEG as pore former affect respectively release rate and burst strength of BZ with different coefficients. Drug release profile in rabbit eye correlated well with that of in vitro (R2 = 0.9861, p ˂ 0.0001). No significant changes were seen in ERG waves, intraocular pressure, and histological studies during the in vivo part of the project. Using 8% HV, 20% PEG/PHBV, and higher molecular weight PEG (i.e., 6000), the optimum formulation was achieved. Toxicity and biocompatibility of the optimized formulation, which were evaluated in vivo, indicated the suitability of design implant for intra-vitreal BZ delivery. Grapical abstract.
Collapse
|
5
|
An Imaging Toolkit for Physical Characterization of Long-Acting Pharmaceutical Implants. J Pharm Sci 2020; 109:2798-2811. [DOI: 10.1016/j.xphs.2020.05.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 05/26/2020] [Accepted: 05/27/2020] [Indexed: 02/06/2023]
|
6
|
Shi NQ, Zhou J, Walker J, Li L, Hong JKY, Olsen KF, Tang J, Ackermann R, Wang Y, Qin B, Schwendeman A, Schwendeman SP. Microencapsulation of luteinizing hormone-releasing hormone agonist in poly (lactic-co-glycolic acid) microspheres by spray-drying. J Control Release 2020; 321:756-772. [PMID: 31935481 DOI: 10.1016/j.jconrel.2020.01.023] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2019] [Revised: 01/02/2020] [Accepted: 01/10/2020] [Indexed: 11/23/2022]
Abstract
A spray drying technique was developed to prepare injectable and biodegradable poly(lactic-co-glycolic acid) (PLGA) microspheres encapsulating a model luteinizing hormone-releasing hormone agonist (LHRHa)-based peptide, leuprolide. Various spray drying parameters were evaluated to prepare 1-month controlled release formulations with a similar composition to the commercial Lupron Depot® (LD). A single water-in-oil emulsion of aqueous leuprolide/gelatin solution in PLGA 75/25 acid capped (13 kDa Mw) dissolved in methylene chloride (DCM) was spray-dried before washing the microspheres in cold ddH2O and freeze-drying. The spray-drying microencapsulation was characterized by: particle size/distribution (span), morphology, drug/gelatin loading, encapsulation efficiency, and residual DCM and water content. Long-term release was tested over 9 weeks in PBS + 0.02% Tween 80 + 0.02% sodium azide pH 7.4 (PBST) at 37 °C. Several physical-chemical parameters were monitored simultaneously for selected formulations, including: water uptake, mass loss, dry and hydrated glass transition temperature, to help understand the related long-term release profiles and explore the underlying controlled-release mechanisms. Compared with the commercial LD microspheres, some of the in-house spray-dried microspheres presented highly similar or even improved long-term release profiles, providing viable long-acting release (LAR) alternatives to the LD. The in vitro release mechanism of the peptide was shown to be controlled either by kinetics of polymer mass loss or by a second process, hypothesized to involve peptide desorption from the polymer. These data indicate spray drying can be optimized to prepare commercially relevant PLGA microsphere formulations for delivery of peptides, including the LHRHa, leuprolide.
Collapse
Affiliation(s)
- Nian-Qiu Shi
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA; School of Pharmacy, Jilin Medical University, Jilin 132013, Jilin Province, China
| | - Jia Zhou
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Jennifer Walker
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Li Li
- School of Pharmaceutical Science, Liaoning University, Jilin 132013, Jilin Province, China
| | - Justin K Y Hong
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Karl F Olsen
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Jie Tang
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Rose Ackermann
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Yan Wang
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD 20993, USA
| | - Bin Qin
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD 20993, USA
| | - Anna Schwendeman
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA
| | - Steven P Schwendeman
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA; Department of Biomedical Engineering, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109, USA.
| |
Collapse
|
7
|
Mohtashami Z, Esmaili Z, Vakilinezhad MA, Seyedjafari E, Akbari Javar H. Pharmaceutical implants: classification, limitations and therapeutic applications. Pharm Dev Technol 2019; 25:116-132. [DOI: 10.1080/10837450.2019.1682607] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Zahra Mohtashami
- Pharmaceutics Department, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Zahra Esmaili
- Pharmaceutics Department, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | - Hamid Akbari Javar
- Pharmaceutics Department, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
8
|
Mandal A, Pal D, Agrahari V, Trinh HM, Joseph M, Mitra AK. Ocular delivery of proteins and peptides: Challenges and novel formulation approaches. Adv Drug Deliv Rev 2018; 126:67-95. [PMID: 29339145 DOI: 10.1016/j.addr.2018.01.008] [Citation(s) in RCA: 134] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Revised: 12/21/2017] [Accepted: 01/10/2018] [Indexed: 12/12/2022]
Abstract
The impact of proteins and peptides on the treatment of various conditions including ocular diseases over the past few decades has been advanced by substantial breakthroughs in structural biochemistry, genetic engineering, formulation and delivery approaches. Formulation and delivery of proteins and peptides, such as monoclonal antibodies, aptamers, recombinant proteins and peptides to ocular tissues poses significant challenges owing to their large size, poor permeation and susceptibility to degradation. A wide range of advanced drug delivery systems including polymeric controlled release systems, cell-based delivery and nanowafers are being exploited to overcome the challenges of frequent administration to ocular tissues. The next generation systems integrated with new delivery technologies are anticipated to generate improved efficacy and safety through the expansion of the therapeutic target space. This review will highlight recent advances in formulation and delivery strategies of protein and peptide based biopharmaceuticals. We will also describe the current state of proteins and peptides based ocular therapy and future therapeutic opportunities.
Collapse
|
9
|
Souza MJ, Redig P, Cox SK. Plasma Concentrations of Itraconazole, Voriconazole, and Terbinafine When Delivered by an Impregnated, Subcutaneous Implant in Japanese Quail (Coturnix japonica). J Avian Med Surg 2017. [DOI: 10.1647/2016-177] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Validation of a cage implant system for assessing in vivo performance of long-acting release microspheres. Biomaterials 2016; 109:88-96. [DOI: 10.1016/j.biomaterials.2016.07.041] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 07/28/2016] [Accepted: 07/31/2016] [Indexed: 12/11/2022]
|
11
|
Fernandes-Cunha GM, Rezende CMF, Mussel WN, da Silva GR, de L Gomes EC, Yoshida MI, Fialho SL, Goes AM, Gomes DA, de Almeida Vitor RW, Silva-Cunha A. Anti-Toxoplasma activity and impact evaluation of lyophilization, hot molding process, and gamma-irradiation techniques on CLH-PLGA intravitreal implants. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2016; 27:10. [PMID: 26676856 DOI: 10.1007/s10856-015-5621-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Accepted: 11/05/2015] [Indexed: 06/05/2023]
Abstract
Intraocular delivery systems have been developed to treat many eye diseases, especially those affecting the posterior segment of the eye. However, ocular toxoplasmosis, the leading cause of infectious posterior uveitis in the world, still lacks an effective treatment. Therefore, our group developed an intravitreal polymeric implant to release clindamycin, a potent anti-Toxoplasma antibiotic. In this work, we used different techniques such as differential scanning calorimetry, thermogravimetry, X-ray diffraction, scanning electron microscopy, and fourier-transform infrared spectroscopy to investigate drug/polymer properties while manufacturing the delivery system. We showed that the lyophilization, hot molding process, and sterilization by gamma irradiation did not change drug/polymer physical-chemistry properties. The drug was found to be homogeneously dispersed into the poly lactic-co-glycolic acid (PLGA) chains and the profile release was characterized by an initial burst followed by prolonged release. The drug profile release was not modified after gamma irradiation and non-covalent interaction was found between the drug and the PLGA. We also observed the preservation of the drug activity by showing the potent anti-Toxoplasma effect of the implant, after 24-72 h in contact with cells infected by the parasite, which highlights this system as an alternative to treat toxoplasmic retinochoroiditis.
Collapse
Affiliation(s)
- Gabriella M Fernandes-Cunha
- Faculty of Pharmacy of the Federal University of Minas Gerais, Av. Presidente Antônio Carlos, 6627, Belo Horizonte, MG, 31270-901, Brazil.
| | - Cíntia M F Rezende
- Department of Biochemistry and Immunology Department, Institute of Biological Science of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Wagner N Mussel
- Chemistry Department of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Gisele R da Silva
- School of Pharmacy, Federal University of Sao Joao del-Rei, Divinópolis, MG, Bazil
| | - Elionai C de L Gomes
- Laboratory of Thermal Analysis, Chemistry Department of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Maria I Yoshida
- Laboratory of Thermal Analysis, Chemistry Department of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | | | - Alfredo M Goes
- Department of Biochemistry and Immunology Department, Institute of Biological Science of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Dawison A Gomes
- Department of Biochemistry and Immunology Department, Institute of Biological Science of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Ricardo W de Almeida Vitor
- Department of Parasitology, Institute of Biological Science of the Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Armando Silva-Cunha
- Faculty of Pharmacy of the Federal University of Minas Gerais, Av. Presidente Antônio Carlos, 6627, Belo Horizonte, MG, 31270-901, Brazil
| |
Collapse
|
12
|
Pastor JC, Rojas J, Pastor-Idoate S, Di Lauro S, Gonzalez-Buendia L, Delgado-Tirado S. Proliferative vitreoretinopathy: A new concept of disease pathogenesis and practical consequences. Prog Retin Eye Res 2015. [PMID: 26209346 DOI: 10.1016/j.preteyeres.2015.07.005] [Citation(s) in RCA: 217] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
During the last four decades, proliferative vitreoretinopathy (PVR) has defied the efforts of many researchers to prevent its occurrence or development. Thus, PVR is still the major complication following retinal detachment (RD) surgery and a bottle-neck for advances in cell therapy that require intraocular surgery. In this review we tried to combine basic and clinical knowledge, as an example of translational research, providing new and practical information for clinicians. PVR was defined as the proliferation of cells after RD. This idea was used for classifying PVR and also for designing experimental models used for testing many drugs, none of which were successful in humans. We summarize current information regarding the pathogenic events that follow any RD because this information may be the key for understanding and treating the earliest stages of PVR. A major focus is made on the intraretinal changes derived mainly from retinal glial cell reactivity. These responses can lead to intraretinal PVR, an entity that has not been clearly recognized. Inflammation is one of the major components of PVR, and we describe new genetic biomarkers that have the potential to predict its development. New treatment approaches are analyzed, especially those directed towards neuroprotection, which can also be useful for preventing visual loss after any RD. We also summarize the results of different surgical techniques and clinical information that is oriented toward the identification of high risk patients. Finally, we provide some recommendations for future classification of PVR and for designing comparable protocols for testing new drugs or techniques.
Collapse
Affiliation(s)
- J Carlos Pastor
- Retina Group, IOBA (Eye Institute), University of Valladolid, Valladolid, Spain; Department of Ophthalmology, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
| | - Jimena Rojas
- Retina Group, IOBA (Eye Institute), University of Valladolid, Valladolid, Spain; Department of Ophthalmology, Hospital Universitario Austral, Universidad Austral, Buenos Aires, Argentina
| | - Salvador Pastor-Idoate
- Retina Group, IOBA (Eye Institute), University of Valladolid, Valladolid, Spain; Manchester Royal Eye Hospital, Manchester Vision Regeneration (MVR) Lab at NIHR/Wellcome Trust, Manchester, United Kingdom
| | - Salvatore Di Lauro
- Retina Group, IOBA (Eye Institute), University of Valladolid, Valladolid, Spain; Department of Ophthalmology, Hospital Clinico Universitario de Valladolid, Valladolid, Spain
| | - Lucia Gonzalez-Buendia
- Retina Group, IOBA (Eye Institute), University of Valladolid, Valladolid, Spain; Department of Ophthalmology, Hospital Clinico Universitario de Valladolid, Valladolid, Spain
| | - Santiago Delgado-Tirado
- Retina Group, IOBA (Eye Institute), University of Valladolid, Valladolid, Spain; Department of Ophthalmology, Hospital Clinico Universitario de Valladolid, Valladolid, Spain
| |
Collapse
|
13
|
Yasin MN, Svirskis D, Seyfoddin A, Rupenthal ID. Implants for drug delivery to the posterior segment of the eye: A focus on stimuli-responsive and tunable release systems. J Control Release 2014; 196:208-21. [DOI: 10.1016/j.jconrel.2014.09.030] [Citation(s) in RCA: 85] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2014] [Revised: 09/28/2014] [Accepted: 09/30/2014] [Indexed: 12/21/2022]
|
14
|
Schwendeman SP, Shah RB, Bailey BA, Schwendeman AS. Injectable controlled release depots for large molecules. J Control Release 2014; 190:240-53. [PMID: 24929039 PMCID: PMC4261190 DOI: 10.1016/j.jconrel.2014.05.057] [Citation(s) in RCA: 139] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Accepted: 05/28/2014] [Indexed: 11/23/2022]
Abstract
Biodegradable, injectable depot formulations for long-term controlled drug release have improved therapy for a number of drug molecules and led to over a dozen highly successful pharmaceutical products. Until now, success has been limited to several small molecules and peptides, although remarkable improvements have been accomplished in some of these cases. For example, twice-a-year depot injections with leuprolide are available compared to the once-a-day injection of the solution dosage form. Injectable depots are typically prepared by encapsulation of the drug in poly(lactic-co-glycolic acid) (PLGA), a polymer that is used in children every day as a resorbable suture material, and therefore, highly biocompatible. PLGAs remain today as one of the few "real world" biodegradable synthetic biomaterials used in US FDA-approved parenteral long-acting-release (LAR) products. Despite their success, there remain critical barriers to the more widespread use of PLGA LARproducts, particularly for delivery of more peptides and other large molecular drugs, namely proteins. In this review, we describe key concepts in the development of injectable PLGA controlled-release depots for peptides and proteins, and then use this information to identify key issues impeding greater widespread use of PLGA depots for this class of drugs. Finally, we examine important approaches, particularly those developed in our research laboratory, toward overcoming these barriers to advance commercial LAR development.
Collapse
Affiliation(s)
- Steven P Schwendeman
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, North Campus Research Complex, University of Michigan, 2800 Plymouth Road, Ann Arbor, MI 48109, USA; Department of Biomedical Engineering, The Biointerfaces Institute, North Campus Research Complex, University of Michigan, 2800 Plymouth Road, Ann Arbor, MI 48109, USA
| | - Ronak B Shah
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, North Campus Research Complex, University of Michigan, 2800 Plymouth Road, Ann Arbor, MI 48109, USA
| | - Brittany A Bailey
- Department of Pharmaceutical Sciences, The Biointerfaces Institute, North Campus Research Complex, University of Michigan, 2800 Plymouth Road, Ann Arbor, MI 48109, USA
| | - Anna S Schwendeman
- Department of Medicinal Chemistry, The Biointerfaces Institute, North Campus Research Complex, University of Michigan, 2800 Plymouth Road, Ann Arbor, MI 48109, USA
| |
Collapse
|
15
|
Kim YC, Chiang B, Wu X, Prausnitz MR. Ocular delivery of macromolecules. J Control Release 2014; 190:172-81. [PMID: 24998941 PMCID: PMC4142116 DOI: 10.1016/j.jconrel.2014.06.043] [Citation(s) in RCA: 162] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2014] [Accepted: 06/23/2014] [Indexed: 12/22/2022]
Abstract
Biopharmaceuticals are making increasing impact on medicine, including treatment of indications in the eye. Macromolecular drugs are typically given by physician-administered invasive delivery methods, because non-invasive ocular delivery methods, such as eye drops, and systemic delivery, have low bioavailability and/or poor ocular targeting. There is a need to improve delivery of biopharmaceuticals to enable less-invasive delivery routes, less-frequent dosing through controlled-release drug delivery and improved drug targeting within the eye to increase efficacy and reduce side effects. This review discusses the barriers to drug delivery via various ophthalmic routes of administration in the context of macromolecule delivery and discusses efforts to develop controlled-release systems for delivery of biopharmaceuticals to the eye. The growing number of macromolecular therapies in the eye needs improved drug delivery methods that increase drug efficacy, safety and patient compliance.
Collapse
Affiliation(s)
- Yoo Chun Kim
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Bryce Chiang
- Wallace Coulter Department of Biomedical Engineering at Georgia Tech and Emory University, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Xianggen Wu
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong Academy of Medical Sciences, Qingdao 266071, China
| | - Mark R Prausnitz
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; Wallace Coulter Department of Biomedical Engineering at Georgia Tech and Emory University, Georgia Institute of Technology, Atlanta, GA 30332, USA.
| |
Collapse
|
16
|
Fisher PD, Palomino P, Milbrandt TA, Hilt JZ, Puleo DA. Improved small molecule drug release from in situ forming poly(lactic-co-glycolic acid) scaffolds incorporating poly(β-amino ester) and hydroxyapatite microparticles. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2014; 25:1174-93. [PMID: 24903524 DOI: 10.1080/09205063.2014.923368] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
In situ forming implants are an attractive choice for controlled drug release into a fixed location. Currently, rapidly solidifying solvent exchange systems suffer from a high initial burst, and sustained release behavior is tied to polymer precipitation and degradation rate. The present studies investigated addition of hydroxyapatite (HA) and drug-loaded poly(β-amino ester) (PBAE) microparticles to in situ forming poly(lactic-co-glycolic acid) (PLGA)-based systems to prolong release and reduce burst. PBAEs were synthesized, imbibed with simvastatin (osteogenic) or clodronate (anti-resorptive), and then ground into microparticles. Microparticles were mixed with or without HA into a PLGA solution, and the mixture was injected into buffer, leading to precipitation and creating solid scaffolds with embedded HA and PBAE microparticles. Simvastatin release was prolonged through 30 days, and burst release was reduced from 81 to 39% when loaded into PBAE microparticles. Clodronate burst was reduced from 49 to 32% after addition of HA filler, but release kinetics were unaffected after loading into PBAE microparticles. Scaffold dry mass remained unchanged through day 15, with a pronounced increase in degradation rate after day 30, while wet scaffolds experienced a mass increase through day 25 due to swelling. Porosity and pore size changed throughout degradation, likely due to a combination of swelling and degradation. The system offers improved release kinetics, multiple release profiles, and rapid solidification compared to traditional in situ forming implants.
Collapse
Affiliation(s)
- Paul D Fisher
- a Department of Biomedical Engineering , University of Kentucky , Lexington , KY 40506 , USA
| | | | | | | | | |
Collapse
|
17
|
Treuel L, Brandholt S, Maffre P, Wiegele S, Shang L, Nienhaus GU. Impact of protein modification on the protein corona on nanoparticles and nanoparticle-cell interactions. ACS NANO 2014; 8:503-13. [PMID: 24377255 DOI: 10.1021/nn405019v] [Citation(s) in RCA: 287] [Impact Index Per Article: 28.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Recent studies have firmly established that cellular uptake of nanoparticles is strongly affected by the presence and the physicochemical properties of a protein adsorption layer around these nanoparticles. Here, we have modified human serum albumin (HSA), a serum protein often used in model studies of protein adsorption onto nanoparticles, to alter its surface charge distribution and investigated the consequences for protein corona formation around small (radius ∼5 nm), dihydrolipoic acid-coated quantum dots (DHLA-QDs) by using fluorescence correlation spectroscopy. HSA modified by succinic anhydride (HSAsuc) to generate additional carboxyl groups on the protein surface showed a 3-fold decreased binding affinity toward the nanoparticles. A 1000-fold enhanced affinity was observed for HSA modified by ethylenediamine (HSAam) to increase the number of amino functions on the protein surface. Remarkably, HSAsuc formed a much thicker protein adsorption layer (8.1 nm) than native HSA (3.3 nm), indicating that it binds in a distinctly different orientation on the nanoparticle, whereas the HSAam corona (4.6 nm) is only slightly thicker. Notably, protein binding to DHLA-QDs was found to be entirely reversible, independent of the modification. We have also measured the extent and kinetics of internalization of these nanoparticles without and with adsorbed native and modified HSA by HeLa cells. Pronounced variations were observed, indicating that even small physicochemical changes of the protein corona may affect biological responses.
Collapse
Affiliation(s)
- Lennart Treuel
- Institute of Applied Physics and Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT) , 76128 Karlsruhe, Germany
| | | | | | | | | | | |
Collapse
|
18
|
Perez AC, Cunha Junior ADS, Fialho SL, Silva LM, Dorgam JV, Murashima ADAB, Silva AR, Rossato M, Anselmo-Lima WT. Assessing the maxillary sinus mucosa of rabbits in the presence of biodegradable implants. Braz J Otorhinolaryngol 2013; 78:40-6. [PMID: 23306566 PMCID: PMC9446343 DOI: 10.5935/1808-8694.20120031] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2012] [Accepted: 08/23/2012] [Indexed: 11/25/2022] Open
Abstract
In an attempt to improve the quality of life of patients with vitreous humor disease, ophthalmologists began offering steroid-eluting biodegradable implants to their patients. These implants can be used as an alternative treatment for CRS and this is why this experimental study was carried out on rabbit maxillary sinuses. Objective This study aims to assess the histology of the mucosa of the maxillary sinuses of rabbits after the placement of a prednisolone-eluting biodegradable implant. Method Eighteen rabbits were randomly divided into two groups: group 1 - subjects had drug-eluting implants placed on their left maxillary sinuses; group 2 - subjects had non-drug-eluting implants placed on their left maxillary sinuses. The right maxillary sinuses served as the controls. After seven, 14, and 28 days three rabbits in each group were randomly picked to have their tissue inflammatory response assessed. Results Levels of mucosal inflammation were not significantly different between the groups with and without drug-eluting implants and the control group, or when the groups with drug-eluting implants and non-drug-eluting implants were compared. Conclusion Signs of toxicity or mucosal inflammation were not observed in the maxillary sinuses of rabbits given prednisolone-eluting implants or non-drug-eluting implants.
Collapse
Affiliation(s)
- André Coura Perez
- Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Av. Bandeirantes no. 3900, Ribeirão Preto - SP, Brazil.
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Abstract
The synthesis of a porous polysulfone (PSU) coating for use in drug delivery applications is presented. PSU can serve as a functional surface coating for drug delivery vehicles, such as intraocular biomicrorobots. The coatings can be applied using spin coating or dip coating. The porosity is introduced by selectively dissolving calcium carbonate nanoparticles embedded in the bulk polymer. The network of pores thus formed increases by a factor of thirty the amount of Rhodamine B (model drug) that can be loaded and by a factor of fifteen the amount that can be released. The films do not affect cell viability and exhibit poor cell adhesion. The straightforward synthesis and predictability of porosity enables the tuning of the amount of drug that can be loaded.
Collapse
|
20
|
Choonara YE, Pillay V, Carmichael TR, Meyer LC, Du Toit LC, Naylor S, Wanblad C. In Vivo Evaluation of a Biodegradable Donut-Shaped Minitablet for Prolonged Posterior Segment Drug Delivery in the Rabbit Eye Model. J Pharm Sci 2011; 100:1819-32. [DOI: 10.1002/jps.22421] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2010] [Revised: 09/22/2010] [Accepted: 11/09/2010] [Indexed: 11/08/2022]
|
21
|
Preparation, characterization and in vivo pharmacodynamic evaluation of thymopentin loaded poly(lactide acid)/poly(lactide-co-glycolide acid) implants. Int J Pharm 2010; 398:123-9. [DOI: 10.1016/j.ijpharm.2010.07.036] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2010] [Revised: 07/09/2010] [Accepted: 07/22/2010] [Indexed: 11/20/2022]
|
22
|
Ahmed AR, Elkharraz K, Irfan M, Bodmeier R. Reduction in burst release after coating poly(D,L-lactide-co-glycolide) (PLGA) microparticles with a drug-free PLGA layer. Pharm Dev Technol 2010; 17:66-72. [PMID: 20854130 DOI: 10.3109/10837450.2010.513989] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The high initial burst release of a highly water-soluble drug from poly (D,L-lactide-co-glycolide) (PLGA) microparticles prepared by the multiple emulsion (w/o/w) solvent extraction/evaporation method was reduced by coating with an additional polymeric PLGA layer. Coating with high encapsulation efficiency was performed by dispersing the core microparticles in peanut oil and subsequently in an organic polymer solution, followed by emulsification in the aqueous solution. Hardening of an additional polymeric layer occurred by oil/solvent extraction. Peanut oil was used to cover the surface of core microparticles and, therefore, reduced or prevented the rapid erosion of core microparticles surface. A low initial burst was obtained, accompanied by high encapsulation efficiency and continuous sustained release over several weeks. Reduction in burst release after coating was independent of the amount of oil. Either freshly prepared (wet) or dried (dry) core microparticles were used. A significant initial burst was reduced when ethyl acetate was used as a solvent instead of methylene chloride for polymer coating. Multiparticle encapsulation within the polymeric layer increased as the size of the core microparticles decreased (< 50 µm), resulting in lowest the initial burst. The initial burst could be controlled well by the coating level, which could be varied by varying the amount of polymer solution, used for coating.
Collapse
Affiliation(s)
- Abid Riaz Ahmed
- College of Pharmacy, Freie Universität Berlin, Kelchstr. 31, 12169 Berlin, Germany.
| | | | | | | |
Collapse
|
23
|
Chaudhari KR, Shah N, Patel H, Murthy R. Preparation of porous PLGA microspheres with thermoreversible gel to modulate drug release profile of water-soluble drug: bleomycin sulphate. J Microencapsul 2010; 27:303-13. [PMID: 20128747 DOI: 10.3109/02652040903191818] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Bleomycin sulphate-loaded porous microspheres were prepared using modified solvent evaporation method (w/o/w) using PLGA50:50 as a polymeric system. The prepared microspheres were incorporated in pluronic (F127) based thermoreversible gel to develop a depot formulation. Various process parameters as solvent evaporation temperature and formulation parameters such as surfactant concentration, volume of internal and external phase and drug-to-polymer ratio were optimized for enhancing percentage drug entrapment, percentage drug loading and desired release profile by controlling size and porosity of the microspheres. Microspheres were characterized for particle size, zeta potential, surface morphology, percentage drug loading and in vitro drug release study after incorporated in gel. The formulated microspheres were porous in nature and showed biphasic in vitro drug release profile. The microspheres incorporated in pluronic (F127) gel showed sustained release up to 1 week and may be useful for treatment of squamous cell carcinoma with better therapeutic effect.
Collapse
Affiliation(s)
- Kiran R Chaudhari
- Maharaja Sayajirao University of Baroda, Drug Delivery Research Laboratory, Ctr Relevance and Excellence NDDS, Department of Pharmaceutics, Baroda, India
| | | | | | | |
Collapse
|
24
|
Silva GRD, Fialho SL, Siqueira RC, Jorge R, Cunha Júnior ADS. Implants as drug delivery devices for the treatment of eye diseases. BRAZ J PHARM SCI 2010. [DOI: 10.1590/s1984-82502010000300024] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The treatment of diseases affecting the posterior segment of the eye is limited by the difficulty in transporting effective doses of drugs to the vitreous, retina, and choroid. Topically applied drugs are poorly absorbed due to the low permeability of the external ocular tissues and tearing. The blood-retina barrier limits drug diffusion from the systemic blood to the posterior segment, thus high doses of drug are needed to maintain therapeutic levels. In addition, systemic side effects are common. Intraocular injections could be an alternative, but the fast flowing blood supply in this region, associated with rapid clearance rates, causes drug concentration to quickly fall below therapeutic levels. To obtain therapeutic levels over longer time periods, polymeric sustained-drug release systems implanted within the vitreous are being studied for the treatment of vitreoretinal disorders. These systems are prepared using different kinds of biodegradable or non-biodegradable polymers. This review aims to demonstrate the main characteristics of these drug delivery implants and their potential for clinical application.
Collapse
|
25
|
Clawson C, Huang CT, Futalan D, Seible DM, Saenz R, Larsson M, Ma W, Minev B, Zhang F, Ozkan M, Ozkan C, Esener S, Messmer D. Delivery of a peptide via poly(D,L-lactic-co-glycolic) acid nanoparticles enhances its dendritic cell-stimulatory capacity. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2010; 6:651-61. [PMID: 20348031 DOI: 10.1016/j.nano.2010.03.001] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2009] [Revised: 03/01/2010] [Accepted: 03/06/2010] [Indexed: 11/27/2022]
Abstract
UNLABELLED Nanoparticles (NPs) are attractive carriers for vaccines. We have previously shown that a short peptide (Hp91) activates dendritic cells (DCs), which are critical for initiation of immune responses. In an effort to develop Hp91 as a vaccine adjuvant with NP carriers, we evaluated its activity when encapsulated in or conjugated to the surface of poly(d,l-lactic-co-glycolic) acid (PLGA) NPs. We found that Hp91, when encapsulated in or conjugated to the surface of PLGA-NPs, not only activates both human and mouse DCs, but is in fact more potent than free Hp91. Hp91 packaged within NPs was about fivefold more potent than the free peptide, and Hp91 conjugated to the surface of NPs was ∼20-fold more potent than free Hp91. Because of their capacity to activate DCs, such NP-Hp91 systems are promising as delivery vehicles for subunit vaccines against infectious disease or cancer. FROM THE CLINICAL EDITOR In this paper, nanoparticle-based dendritic cell activating vaccines are described and discussed. The authors report that the presented PLGA NP based vaccine constructs increase the potency of the studied vaccine by up to 20-fold, making them promising as delivery vehicles for subunit vaccines against infectious diseases or cancer.
Collapse
Affiliation(s)
- Corbin Clawson
- Department of Bioengineering, University of California-San Diego, La Jolla, CA 92093-0815, USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Bali E, Feron EJ, Peperkamp E, Veckeneer M, Mulder PG, van Meurs JC. The effect of a preoperative subconjuntival injection of dexamethasone on blood-retinal barrier breakdown following scleral buckling retinal detachment surgery: a prospective randomized placebo-controlled double blind clinical trial. Graefes Arch Clin Exp Ophthalmol 2010; 248:957-62. [PMID: 20182883 PMCID: PMC2877815 DOI: 10.1007/s00417-010-1319-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2009] [Revised: 01/25/2010] [Accepted: 01/31/2010] [Indexed: 11/30/2022] Open
Abstract
Background Blood–retinal barrier breakdown secondary to retinal detachment and retinal detachment repair is a factor in the pathogenesis of proliferative vitreoretinopathy (PVR). We wished to investigate whether an estimated 700 to 1000 ng/ml subretinal dexamethasone concentration at the time of surgery would decrease the blood–retinal barrier breakdown postoperatively. Methods Prospective, placebo-controlled, double blind clinical trial. In 34 patients with rhegmatogenous retinal detachment scheduled for conventional scleral buckling retinal detachment surgery, a subconjunctival injection of 0.5 ml dexamethasone diphosphate (10 mg) or 0.5 ml placebo was given 5–6 hours before surgery. Differences in laser flare photometry (KOWA) measurements taken 1, 3 and 6 weeks after randomisation between dexamethasone and placebo were analysed using mixed model ANOVA, while correcting for the preoperative flare measurement. Results Six patients did not complete the study, one because of recurrent detachment within 1 week, and five because they missed their postoperative laser flare visits. The use of dexamethasone resulted in a statistically significant decrease in laser flare measurements at the 1-week postoperative visit. Conclusion The use of a preoperative subconjunctival injection of dexamethasone decreased 1-week postoperative blood–retina barrier breakdown in patients undergoing conventional scleral buckling retinal detachment surgery. This steroid priming could be useful as a part of a peri-operative regime that would aim at decreasing the incidence of PVR.
Collapse
Affiliation(s)
- Ernesto Bali
- The Rotterdam Eye Hospital, Rotterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|
27
|
Mack BC, Wright KW, Davis ME. A biodegradable filament for controlled drug delivery. J Control Release 2009; 139:205-11. [DOI: 10.1016/j.jconrel.2009.06.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2009] [Revised: 05/26/2009] [Accepted: 06/22/2009] [Indexed: 11/29/2022]
|
28
|
Sivak WN, Zhang J, Petoud S, Beckman EJ. Simultaneous drug release at different rates from biodegradable polyurethane foams. Acta Biomater 2009; 5:2398-408. [PMID: 19398389 DOI: 10.1016/j.actbio.2009.03.036] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2009] [Revised: 02/21/2009] [Accepted: 03/24/2009] [Indexed: 11/26/2022]
Abstract
In this study, we present an approach for the simultaneous release of multiple drug compounds at different rates from single-phase polyurethane foams constructed from lysine diisocyanate (LDI) and glycerol. The anti-cancer compounds DB-67 and doxorubicin were covalently incorporated into polyurethane foams, whereby drug release can then occur in concert with material degradation. To begin, the reactions of DB-67 and doxorubicin with LDI in the presence of a tertiary amine catalyst were monitored with infrared spectroscopy; each compound formed urethane linkages with LDI. Fluorescent spectra of DB-67 and doxorubicin were then recorded in phosphate-buffered saline, pH 7.4 (PBS), to ensure that each anti-cancer compound could be quantitatively detected alone and in combination. Doxorubicin and DB-67 were then incorporated into a series of degradable LDI-glycerol polyurethane foams alone and in combination with one another. The sol content, average porosity and drug distribution throughout each foam sample was measured and found to be similar amongst all foam samples. The stability of DB-67 and doxorubicin's fluorescent signal was then assessed over a 2-week period at 70 degrees C. Release rates of the compounds from the foams were assessed over a 10-week period at 4, 22, 37 and 70 degrees C by way of fluorescence spectroscopy. Release was found to be temperature-dependent, with rates related to the chemical structure of the incorporated drug. This study demonstrates that differential release of covalently bound drugs is possible from simple single-phase, degradable polyurethane foams.
Collapse
|
29
|
Fialho SL, Rêgo MB, Siqueira RC, Jorge R, Haddad A, Rodrigues AL, Maia-Filho A, Silva-Cunha A. Safety and Pharmacokinetics of an Intravitreal Biodegradable Implant of Dexamethasone Acetate in Rabbit Eyes. Curr Eye Res 2009; 31:525-34. [PMID: 16769612 DOI: 10.1080/02713680600719036] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
The treatment of vitreoretinal diseases is limited and, nowadays, new drug delivery approaches have been reported in order to increase drug bioavailability. The objective of the current study was to determine the pharmacokinetic profile of a biodegradable dexamethasone acetate implant inserted into the vitreous of rabbits and to evaluate its potential signs of toxicity to the rabbits' eyes. The results showed that the intravitreous drug concentration remained within the therapeutic range along the 8-week period of evaluation. The system under study was not toxic to the normal rabbit retina, and no significant increase in intraocular pressure was observed.
Collapse
Affiliation(s)
- S L Fialho
- Faculty of Pharmacy, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Biodegradable Intrascleral Implant of Triamcinolone Acetonide in Experimental Uveitis. J Ocul Pharmacol Ther 2009; 25:201-8. [DOI: 10.1089/jop.2008.0086] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
31
|
Intraocular sustained-release delivery systems for triamcinolone acetonide. Pharm Res 2009; 26:770-84. [PMID: 19184374 DOI: 10.1007/s11095-008-9812-z] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2008] [Accepted: 12/11/2008] [Indexed: 02/06/2023]
Abstract
Recently, the use of triamcinolone acetonide (TA) injection has increased dramatically in treatment for several ocular diseases. Among them, macular diseases such as macular edema due to diabetic retinopathy, venous occlusive diseases, ocular inflammation and age-related macular degeneration (AMD) are very common vision threatening disorders and are great challenges to treat. In these types of chronic retinal diseases, repeated intraocular injections of TA are often required which increases the likelihood of complications. In order to achieve sustained-release, maintain therapeutic levels of TA over longer times and reduce frequency of intravitreal injections, researchers are investigating different implantable devices or injectable systems. However, as of yet, there is no sustained-release product for TA available on the commercial market. This review discusses and compares different sustained-release devices or injectable systems that are currently being developed.
Collapse
|
32
|
Fialho SL, da Silva Cunha A. Manufacturing Techniques of Biodegradable Implants Intended for Intraocular Application. Drug Deliv 2008; 12:109-16. [PMID: 15824036 DOI: 10.1080/10717540590921432] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Polylactic acid and polylactic-co-glycolic acid are biocompatible and biodegradable polymers with wide utility for the design of controlled release systems for drugs. Regarding intraocular application, polymeric sustained-drug release systems are being studied to treat vitreoretinal diseases. Our work aimed to compare the influence of two implant manufacturing techniques, compression and hot molding, on the in vitro degradation of the polymeric matrices and on the release of dexamethasone acetate. The results showed that the manufacturing technique highly influences degradation and drug release processes. The compressed systems degraded faster and allowed one faster release of the drug.
Collapse
Affiliation(s)
- Sílvia Ligório Fialho
- Faculty of Pharmacy, Federal University of Minas Gerais, Avenida Antônio Carlos 6627, CEP 31270-010, Belo Horizonte, Minas Gerais, Brazil.
| | | |
Collapse
|
33
|
Abstract
Anatomy and physiology of the eye makes it a highly protected organ. Designing an effective therapy for ocular diseases, especially for the posterior segment, has been considered as a formidable task. Limitations of topical and intravitreal route of administration have challenged scientists to find alternative mode of administration like periocular routes. Transporter targeted drug delivery has generated a great deal of interest in the field because of its potential to overcome many barriers associated with current therapy. Application of nanotechnology has been very promising in the treatment of a gamut of diseases. In this review, we have briefly discussed several ocular drug delivery systems such as microemulsions, nanosuspensions, nanoparticles, liposomes, niosomes, dendrimers, implants, and hydrogels. Potential for ocular gene therapy has also been described in this article. In near future, a great deal of attention will be paid to develop non-invasive sustained drug release for both anterior and posterior segment eye disorders. A better understanding of nature of ocular diseases, barriers and factors affecting in vivo performance, would greatly drive the development of new delivery systems. Current momentum in the invention of new drug delivery systems hold a promise towards much improved therapies for the treatment of vision threatening disorders.
Collapse
|
34
|
Wischke C, Schwendeman SP. Principles of encapsulating hydrophobic drugs in PLA/PLGA microparticles. Int J Pharm 2008; 364:298-327. [PMID: 18621492 DOI: 10.1016/j.ijpharm.2008.04.042] [Citation(s) in RCA: 548] [Impact Index Per Article: 34.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2008] [Revised: 04/29/2008] [Accepted: 04/29/2008] [Indexed: 10/22/2022]
Abstract
Injectable biodegradable and biocompatible copolymers of lactic and glycolic acid (PLGA) are an important advanced delivery system for week-to-month controlled release of hydrophobic drugs (e.g., from biopharmaceutical classification system class IV), which often display poor oral bioavailability. The basic principles and considerations to develop such microparticle formulations is reviewed here based on a comprehensive study of papers and patents from the beginnings of hydrophobic drug encapsulation in polylactic acid and PLGA up through the very recent literature. Challenges with the diversity of drug properties, microencapsulation methods, and organic solvents are evaluated in light of the precedence of commercialized formulations and with a focus on decreasing the time to lab-scale encapsulation of water-insoluble drug candidates in the early stage of drug development. The influence of key formulation variables on final microparticle characteristics, and how best to avoid undesired microparticle properties, is analyzed mechanistically. Finally, concepts are developed to manage the common issues of maintaining sink conditions for in vitro drug release assays of hydrophobic compounds. Overall, against the backdrop of an increasing number of new, poorly orally available drug entities entering development, microparticle delivery systems may be a viable strategy to rescue an otherwise undeliverable substance.
Collapse
Affiliation(s)
- Christian Wischke
- Department of Pharmaceutical Sciences, University of Michigan, 428 Church Street, Ann Arbor, MI 48109-1065, USA
| | | |
Collapse
|
35
|
Desai KGH, Mallery SR, Schwendeman SP. Effect of formulation parameters on 2-methoxyestradiol release from injectable cylindrical poly(DL-lactide-co-glycolide) implants. Eur J Pharm Biopharm 2008; 70:187-98. [PMID: 18472254 DOI: 10.1016/j.ejpb.2008.03.007] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2007] [Revised: 03/11/2008] [Accepted: 03/12/2008] [Indexed: 10/22/2022]
Abstract
The objective of this study was to investigate the potential of various formulation strategies to achieve 1-month continuous (improved) release of the novel anti-cancer drug, 2-methoxyestradiol (2-ME), from injectable cylindrical poly(DL-lactide-co-glycolide) (PLGA) implants. PLGA implants were prepared by a solvent extrusion method. PLGA 50:50 (M(w)=51 kDa, end group=lauryl ester) (PLGA-lauryl ester) implants loaded with 3-30 wt% 2-ME exhibited a pronounced lag phase (i.e., corresponding to induction time to polymer mass loss) and triphasic release profile. Incorporation of 5 wt% hydroxypropyl-beta-cyclodextrin (HP-beta-CD) (approximately 57% release after 28 days) or Pluronic F127 (approximately 42% release after 28 days) in PLGA-lauryl ester implants reduced the lag-phase and improved the drug release moderately over a period of 28 days. The formation and the incorporation of a 2-ME/polyethylene glycol (PEG) 8000 solid dispersion in PLGA-lauryl ester implants further increased drug release (approximately 21% and 73% release after 1 and 28 days, respectively), attributable to improved drug solubility/dissolution, higher matrix porosity, and accelerated polymer degradation. Blending of PLGA 50:50 (M(w)=24 kDa, end group=COOH) (PLGA-COOH) with the PLGA-lauryl ester also provided moderate enhancement of 2-ME release over a period of 28 days. PLGA-COOH (M(w)=24 kDa) implants with 3-5% w/w pore-forming MgCO(3) exhibited the most desirable drug release among all the formulations tested, and, demonstrated 1-month slow and continuous in vitro release of approximately 80% 2-ME after a minimal initial burst. Hence, these formulation approaches provide several possible avenues to improve release rates of the hydrophobic drug, 2-ME, from PLGA for future application in regional anti-cancer therapy.
Collapse
Affiliation(s)
- Kashappa Goud H Desai
- Department of Pharmaceutical Sciences, University of Michigan, 428 Church Street, Ann Arbor, MI 48109, USA
| | | | | |
Collapse
|
36
|
Eperon S, Bossy-Nobs L, Petropoulos I, Gurny R, Guex-Crosier Y. A biodegradable drug delivery system for the treatment of postoperative inflammation. Int J Pharm 2008; 352:240-7. [DOI: 10.1016/j.ijpharm.2007.10.054] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2007] [Revised: 10/30/2007] [Accepted: 10/31/2007] [Indexed: 10/22/2022]
|
37
|
Bourges JL, Touchard E, Kowalczuk L, Berdugo M, Thomas-Doyle A, Bochot A, Gomez A, Azan F, Gurny R, Behar-Cohen F. Dispositifs de délivrance de principes actifs pour des applications ophtalmologiques. J Fr Ophtalmol 2007; 30:1070-88. [DOI: 10.1016/s0181-5512(07)79290-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
38
|
Booth BA, Vidal Denham L, Bouhanik S, Jacob JT, Hill JM. Sustained-release ophthalmic drug delivery systems for treatment of macular disorders: present and future applications. Drugs Aging 2007; 24:581-602. [PMID: 17658909 DOI: 10.2165/00002512-200724070-00006] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Macular disease currently poses the greatest threat to vision in aging populations. Historically, most of this pathology could only be dealt with surgically, and then only after much damage to the macula had already occurred. Current pathophysiological insights into macular diseases have allowed the development of effective new pharmacotherapies. The field of drug delivery systems has advanced over the last several years with emphasis placed on controlled release of drug to specific areas of the eye. Its unique location and tendency toward chronic disease make the macula an important and attractive target for drug delivery systems, especially sustained-release systems. This review evaluates the current literature on the research and development of sustained-release posterior segment drug delivery systems that are primarily intended for macular disease with an emphasis on age-related macular degeneration.Current effective therapies include corticosteroids and anti-vascular endothelial growth factor compounds. Recent successes have been reported using anti-angiogenic drugs for therapy of age-related macular degeneration. This review also includes information on implantable devices (biodegradable and non-biodegradable), the use of injected particles (microspheres and liposomes) and future enhanced drug delivery systems, such as ultrasound drug delivery. The devices reviewed show significant drug release over a period of days or weeks. However, macular disorders are chronic diseases requiring years of treatment. Currently, there is no 'gold standard' for therapy and/or drug delivery. Future studies will focus on improving the efficiency and effectiveness of drug delivery to the posterior chamber. If successful, therapeutic modalities will significantly delay loss of vision and improve the quality of life for patients with chronic macular disorders.
Collapse
Affiliation(s)
- Blake A Booth
- Department of Ophthalmology, LSU Health Sciences Center, New Orleans, Louisiana, USA
| | | | | | | | | |
Collapse
|
39
|
Desai KGH, Mallery SR, Schwendeman SP. Formulation and characterization of injectable poly(DL-lactide-co-glycolide) implants loaded with N-acetylcysteine, a MMP inhibitor. Pharm Res 2007; 25:586-97. [PMID: 17891553 PMCID: PMC2405913 DOI: 10.1007/s11095-007-9430-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2007] [Accepted: 08/02/2007] [Indexed: 10/22/2022]
Abstract
PURPOSE The objective of this study was to develop poly(lactic-co-glycolic acid) (PLGA) injectable implants (i.e., millicylinders) with microencapsulated N-acetylcysteine (NAC) for site-specific controlled NAC release, for potential chemopreventive applications in persons with previously excised head and neck cancers. METHODS PLGA 50:50 (i.v.=0.57 dl/g) implants with 1-10 wt% NAC free acid or 10 wt% NAC salts (NAC-Na+, NAC-Mg2+ and NAC-Ca2+) were prepared by solvent extrusion and/or fluid energy micronization (FEM) methods. X-ray diffraction (XRD), scanning electron microscopy (SEM), and differential scanning calorimetry (DSC) studies were performed to evaluate the physical mixing of NAC with PLGA. PLGA implant degradation was studied by kinetics of polymer molecular weight decline (gel permeation chromatography) and mass loss. Release studies were conducted in N2 purged PBS (pH 7.4) at 37 degrees C in evacuated and sealed ampoules. NAC was quantified by HPLC at 210 nm. RESULTS XRD, SEM and DSC studies indicated that NAC had dissolved in the polymer phase at 1-3.5% w/w loading, but became discretely suspended in the polymer at 6-10% w/w. Initial burst and long-term release rate increased with increased drug loading, and release was uncharacteristically rapid at higher loading (6-10% w/w). The cause of the rapid release was linked to extensive plasticization, matrix porosity and general acid catalysis of PLGA degradation caused by the NAC free acid. PLGA millicylinders loaded with 10% w/w NAC-Ca2+ and NAC-Mg2+salts exhibited reduced burst (34 vs 13-22% release within a day of incubation for NAC free acid vs NAC-Ca2+ and NAC-Mg2+salts, respectively) and slow and continuous complete release over 4 weeks without significant NAC-catalyzed degradation of PLGA. Release of NAC from NAC-Ca2+/PLGA implant was slower than that of NAC-Mg2+/PLGA consistent with the lower solubility of the former salt. NAC with its free thiol was rapidly converted to its cystine dimer in the presence of molecular oxygen. PLGA released samples in sealed and evacuated ampoules indicated>80% parent NAC remaining after the 1 month release analysis irrespective of initial NAC free acid and salt forms. CONCLUSION By encapsulating the NAC-Mg2+ and NAC-Ca2+ salts in PLGA implants, the high initial burst, short release duration, and the general acid catalysis caused by the NAC free acid were each prevented and 1-month slow and continuous release was attained with minimal instability of the free thiol group.
Collapse
Affiliation(s)
- Kashappa Goud H Desai
- Department of Pharmaceutical Sciences, University of Michigan, 428 Church St., Ann Arbor, Michigan 48109-1065, USA
| | | | | |
Collapse
|
40
|
Abstract
Research into treatment modalities affecting vision is rapidly progressing due to the high incidence of diseases such as diabetic macular edema, proliferative vitreoretinopathy, wet and dry age-related macular degeneration and cytomegalovirus retinitis. The unique anatomy and physiology of eye offers many challenges to developing effective retinal drug delivery systems. Historically, drugs have been administered to the eye as liquid drops instilled in the cul-de-sac. However retinal drug delivery is a challenging area. The transport of molecules between the vitreous/retina and systemic circulation is restricted by the blood-retinal barrier, which is made up of retinal pigment epithelium and endothelial cells of the retinal blood vessels. An increase in the understanding of drug absorption mechanisms into the retina from local and systemic administration has led to the development of various drug delivery systems, such as biodegradable and non-biodegradable implants, microspheres, nanoparticles and liposomes, gels and transporter-targeted prodrugs. Such diversity in approaches is an indication that there is still a need for an optimized noninvasive or minimally invasive drug delivery system to the eye. A number of large molecular weight compounds (i.e., oligonucleotides, RNA aptamers, peptides and monoclonal antibodies) have been and continue to be introduced as new therapeutic entities. However, for high molecular weight polar compounds the mechanism of epithelial transport is primarily through the tight junctions in the retinal pigment epithelium, as these agents undergo limited transcellular diffusion. Delivery and administration of these new drugs in a safe and effective manner is still a major challenge facing pharmaceutical scientists. In this review article, the authors discuss various drug delivery strategies, devices and challenges associated with drug delivery to the retina.
Collapse
Affiliation(s)
- Kumar G Janoria
- University of Missouri-Kansas City, Department of Pharmaceutical Sciences, School of Pharmacy, 5005 Rockhill Road, Kansas City, MO 64110, USA
| | | | | | | |
Collapse
|
41
|
Ortiz R, Au JLS, Lu Z, Gan Y, Wientjes MG. Biodegradable intraprostatic doxorubicin implants. AAPS JOURNAL 2007; 9:E241-50. [PMID: 17907765 PMCID: PMC2751414 DOI: 10.1208/aapsj0902027] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Systemic chemotherapy is not effective in the treatment of prostate-confined cancer. We developed biodegradable, doxorubicin-loaded cylinders for intraprostatic implantation and evaluated the feasibility of using regional intraprostatic drug therapy to treat prostate-confined cancer. Cylinders were prepared using poly(lactide-co-glycolide) (PLG) or PLG copolymers. The in vitro and in vivo drug release, intraprostatic pharmacokinetics, and histopathology in dogs implanted with the cylinders were studied. The doxorubicin-loaded cylinders made of PLG polymers of 7.9 to 54 kDa molecular weight (MW) had a diameter of ~800 mum, drug loading of 10% to 30% (wt/wt), and even distribution of crystalline drug throughout the matrix. Burst release varied from 3% to 73%, and 7-day cumulative release from 4% to 90%. Decreasing polymer MW and increasing drug loading were associated with higher initial burst release and overall release rates. The in vivo drug release from cylinders (33-kDa PLG, 30% drug loading) in dog prostates was rapid (approximately 80% in 48 hours). Spatial drug distribution, visualized using confocal fluorescence microscopy, showed high concentrations confined to the lobule containing the implant (referred to as the implanted lobule), with steep concentration gradients over the septa separating the lobules. Concentrations in the implanted lobule were about 8 times higher than concentrations delivered by an intravenous injection. The implants caused necrotic cell death in the implanted lobule, without damage to prostatic nerve bundles or the urethra. These results indicate the feasibility of using biodegradable PLG cylinders as intraprostatic implants to selectively deliver high drug concentrations to prostate tissue.
Collapse
Affiliation(s)
- Ronnie Ortiz
- />College of Pharmacy, Ohio State University, 500 West 12th Avenue, Columbus, OH
| | - Jessie L-S. Au
- />College of Pharmacy, Ohio State University, 500 West 12th Avenue, Columbus, OH
- />James Cancer Hospital and Solove Research Institute, Ohio State University, Columbus, OH
| | - Ze Lu
- />College of Pharmacy, Ohio State University, 500 West 12th Avenue, Columbus, OH
| | - Yuebo Gan
- />College of Pharmacy, Ohio State University, 500 West 12th Avenue, Columbus, OH
| | - M. Guillaume Wientjes
- />College of Pharmacy, Ohio State University, 500 West 12th Avenue, Columbus, OH
- />James Cancer Hospital and Solove Research Institute, Ohio State University, Columbus, OH
| |
Collapse
|
42
|
Huang W, Zheng Q, Sun W, Xu H, Yang X. Levofloxacin implants with predefined microstructure fabricated by three-dimensional printing technique. Int J Pharm 2007; 339:33-8. [PMID: 17412538 DOI: 10.1016/j.ijpharm.2007.02.021] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2006] [Revised: 02/11/2007] [Accepted: 02/14/2007] [Indexed: 10/23/2022]
Abstract
A novel three-dimensional (3D) printing technique was utilized in the preparation of drug implants that can be designed to have complex drug release profiles. The method we describe is based on a lactic acid polymer matrix with a predefined microstructure that is amenable to rapid prototyping and fabrication. We describe how the process parameters, especially selection of the binder, were optimized. Implants containing levofloxacin (LVFX) with predefined microstructures using an optimized binder solution of ethanol and acetone (20:80, v/v) were prepared by a 3D printing process that achieved a bi-modal profile displaying both pulsatile and steady state LVFX release from a single implant. The pulse release appeared from day 5 to 25, followed by a steady state phase of 25 days. The next pulse release phase then began at the 50th day and ended at the 80th day. To evaluate the drug implants structurally and analytically, the microscopic morphologies and the in vitro release profiles of the implants fabricated by both the 3D printing technique and the conventional lost mold technique were assessed using environmental scanning electron microscopy (ESEM) and UV absorbance spectrophotometry. The results demonstrate that the 3D printing technology can be used to fabricate drug implants with sophisticated micro- and macro-architecture in a single device that may be rapidly prototyped and fabricated. We conclude that drug implants with predefined microstructure fabricated by 3D printing techniques can have clear advantages compared to implants fabricated by conventional compressing methods.
Collapse
Affiliation(s)
- Weidong Huang
- Institue of Materia Medica, Huazhong University of Science and Technology, Wuhan 430074, China
| | | | | | | | | |
Collapse
|
43
|
Fialho S, Siqueira R, Jorge R, Silva-Cunha A. Biodegradable implants for ocular delivery of anti-inflammatory drug. J Drug Deliv Sci Technol 2007. [DOI: 10.1016/s1773-2247(07)50013-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
44
|
Bourges JL, Bloquel C, Thomas A, Froussart F, Bochot A, Azan F, Gurny R, BenEzra D, Behar-Cohen F. Intraocular implants for extended drug delivery: therapeutic applications. Adv Drug Deliv Rev 2006; 58:1182-202. [PMID: 17107737 DOI: 10.1016/j.addr.2006.07.026] [Citation(s) in RCA: 155] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2006] [Accepted: 07/31/2006] [Indexed: 12/16/2022]
Abstract
An overview of ocular implants with therapeutic application potentials is provided. Various types of implants can be used as slow release devices delivering locally the needed drug for an extended period of time. Thus, multiple periocular or intraocular injections of the drug can be circumvented and secondary complications minimized. The various compositions of polymers fulfilling specific delivery goals are described. Several of these implants are undergoing clinical trials while a few are already commercialized. Despite the paramount progress in design, safety and efficacy, the place of these implants in our clinical therapeutic arsenal remains limited. Miniaturization of the implants allowing for their direct injection without the need for a complicated surgery is a necessary development avenue. Particulate systems which can be engineered to target specifically certain cells or tissues are another promising alternative. For ocular diseases affecting the choroid and outer retina, transscleral or intrasscleral implants are gaining momentum.
Collapse
Affiliation(s)
- J L Bourges
- INSERM, U598, Physiopathology of Ocular Diseases, Therapeutic Innovations, 15 Rue de l'Ecole de Médecine 75006 Paris, France
| | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Felt-Baeyens O, Eperon S, Mora P, Limal D, Sagodira S, Breton P, Simonazzi B, Bossy-Nobs L, Guex-Crosier Y, Gurny R. Biodegradable scleral implants as new triamcinolone acetonide delivery systems. Int J Pharm 2006; 322:6-12. [PMID: 16824708 DOI: 10.1016/j.ijpharm.2006.05.053] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2005] [Revised: 04/20/2006] [Accepted: 05/03/2006] [Indexed: 10/24/2022]
Abstract
The goal of this study was to develop ocular scleral implants able to release triamcinolone acetonide (TA) overall several months. Scleral discs were manufactured by a compression-molding method using a new synthetic polymer, poly(methylidene malonate) (PMM2.1.2), as matrix. Implants with good mechanical properties adapted for in vivo implantation have been obtained when using high M(w) PMM2.1.2 (100,000 - 150,000 Da) associated with ethoxylated derivatives of stearic acid (Simulsol) or oligomers of methylidene malonate as plasticizer. After implantation in rabbit eyes, scleral implants showed a good ocular biocompatibility. Indeed, the clinical follow-up and ocular inflammation parameters, such as inflammatory cell number and protein content in aqueous humor, demonstrated that implants were well tolerated and did not provoke abnormal inflammation. Implants were able to release significant concentrations of TA in the vitreous and the sclera throughout 5 weeks.
Collapse
Affiliation(s)
- O Felt-Baeyens
- Department of Pharmaceutics and Biopharmaceutics, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, 30 Quai Ernest-Ansermet, CH-1211 Geneva 4, Switzerland
| | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Hastedt JE, Wright JL. Percolative Transport and Cluster Diffusion Near and Below the Percolation Threshold of a Porous Polymeric Matrix. Pharm Res 2006; 23:2427-40. [PMID: 16933096 DOI: 10.1007/s11095-006-9072-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2006] [Accepted: 05/22/2006] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this research was to develop a quantitative mass transport model to describe the release of a drug from a porous inert matrix dosage form near and below the percolation threshold for the system. METHODS Cumulative release profiles were generated for a series of tablets composed of a binary mixture of varying amounts of non-conducting (poly(vinyl stearate)) and conducting (benzoic acid) components. The porous microstructure was analyzed using re-constructed three-dimensional images of leached microtomed tablet sections. Poly(vinyl stearate) was characterized for transport properties, molecular weight and thermal properties. RESULTS Based on percolation theory, the binary matrix was determined to have a percolation threshold of 0.09 +/- 0.02. Transport, which could not be explained by "classical" percolation theory or surface diffusion alone, was observed below the percolation threshold for the system. CONCLUSIONS A model describing transport near and below the percolation threshold in matrices composed of two phases, polymer and drug, was developed. The percolation model developed accounts for diffusion within the porous structure and through the inert, insoluble polymeric amorphous regions of the matrix. The low percolation threshold and subsequently high coordination was concluded to be due to the biphasic classical porous and nonclassical polymeric diffusional transport mechanisms associated with the system studied.
Collapse
Affiliation(s)
- Jayne E Hastedt
- Global Chem Pharm, ALZA Corporation, 1010 Joaquin Road, Mountain View, California 94043, USA.
| | | |
Collapse
|
47
|
des Rieux A, Fievez V, Garinot M, Schneider YJ, Préat V. Nanoparticles as potential oral delivery systems of proteins and vaccines: a mechanistic approach. J Control Release 2006; 116:1-27. [PMID: 17050027 DOI: 10.1016/j.jconrel.2006.08.013] [Citation(s) in RCA: 793] [Impact Index Per Article: 44.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2006] [Accepted: 08/08/2006] [Indexed: 12/15/2022]
Abstract
Peptides and proteins remain poorly bioavailable upon oral administration. One of the most promising strategies to improve their oral delivery relies on their association with colloidal carriers, e.g. polymeric nanoparticles, stable in gastrointestinal tract, protective for encapsulated substances and able to modulate physicochemical characteristics, drug release and biological behavior. The mechanisms of transport of these nanoparticles across intestinal mucosa are reviewed. In particular, the influence of size and surface properties on their non-specific uptake or their targeted uptake by enterocytes and/or M cells is discussed. Enhancement of their uptake by appropriate cells, i.e. M cells by (i) modeling surface properties to optimize access to and transport by M cells (ii) identifying surface markers specific to human M cell allowing targeting to M cells and nanoparticles transcytosis is illustrated. Encouraging results upon in vivo testing are reported but low bioavailability and lack of control on absorbed dose slow down products development. Vaccines are certainly the most promising applications for orally delivered nanoparticles.
Collapse
Affiliation(s)
- Anne des Rieux
- Université Catholique de Louvain, Unité de Pharmacie Galénique, Avenue E. Mounier, 73-20, 1200 Brussels, Belgium
| | | | | | | | | |
Collapse
|
48
|
Abstract
Developing an intraocular drug delivery system (DDS) is urgently needed because most vitreoretinal diseases are refractory to conventional pharmacological approaches; eye drops and systemically administered drugs cannot deliver therapeutic drug concentrations into vitreoretinal tissue. Intraocular DDSs address this problem. Intraocular sustained-drug release via implantable devices or injectable microparticles has been investigated to treat vitreoretinal diseases. A nonbiodegradable implant was first used in 1996 for cytomegalovirus retinitis secondary to the acquired immunodeficiency syndrome. Biodegradable implants, composed of hydrophilic or hydrophobic polymers, in the shape of rods, plugs, discs or sheets have been investigated. An injectable rod is presently being assessed in a Phase III trial to treat macular oedema secondary to diabetic retinopathy or branch-retinal vein occlusion. Intraocular DDSs using a biodegradable implant may soon be successfully used to treat serious intraocular disorders.
Collapse
Affiliation(s)
- Tsutomu Yasukawa
- Department of Ophthalmology, Nagoya City University Medical School, Aichi 467-8601, Japan.
| | | | | | | | | |
Collapse
|
49
|
Howard-Sparks M, Al-Ghananeem AM, Pearson AP, Crooks PA. Evaluation of O(3alpha)-, O(21)-di-(N(1)-methyloxycarbonyl-2, 4-dioxo-5-fluoropyrimidinyl) 17alpha-hydroxy-5beta-pregnan-20-one as a novel potential antiangiogenic codrug. J Enzyme Inhib Med Chem 2006; 20:417-28. [PMID: 16335049 DOI: 10.1080/14756360500220319] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Intraocular neovascularization is a complication in a variety of eye diseases, and is a leading cause of visual loss. The purpose of this study was to design and synthesize three novel codrugs of the antiangiostatic steroid, 3alpha, 17alpha, 21-trihydroxy-5beta-pregnan-20-one (trihydroxy steroid, THS) with the cytotoxic agent 5-fluorouracil (5FU) which incorporates either one or two molecules of 5FU attached through carbonate ester linkages at positions O(3), and/or O(21) of the THS molecule. Furthermore, a kinetic study of the O(3alpha)-, O(21)-di-(N(1)-methyloxycarbonyl-2, 4-dioxo-5-fluoropyrimidinyL) 17alpha-hydroxy-5beta-pregnan-20-one (THS-BIS-5FU) codrug was carried out. The overall goal of this codrug strategy was to improve sustained drug delivery of both compounds by overcoming their individual solubility problems, and to thus enhance their bioavailability. The codrug was found to be optimal with superior angiostatic activity using the CAM assay compared to the activity of the parent compounds alone. In the hydrolysis studies 5FU was released at a faster rate than THS with an unknown intermediate observed by HPLC, a rationale and proposed structure and mechanism of the unknown THS derivative is provided.
Collapse
Affiliation(s)
- Michelle Howard-Sparks
- College of Pharmacy, Chandler Medical Center, University of Kentucky, Lexington, Kentucky 40536, USA
| | | | | | | |
Collapse
|
50
|
Pollauf EJ, Berkland C, Kim KK, Pack DW. In vitro degradation of polyanhydride/polyester core-shell double-wall microspheres. Int J Pharm 2006; 301:294-303. [PMID: 16051452 DOI: 10.1016/j.ijpharm.2005.06.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2005] [Revised: 06/06/2005] [Accepted: 06/06/2005] [Indexed: 10/25/2022]
Abstract
Double-wall microspheres (DWMS), comprising distinct polymer core and shell phases, are useful and interesting for controlled-release drug delivery. In particular, the presence of a surface-eroding polymer core may be expected to limit water penetration and, therefore, delay degradation of the core phase and drug release. In this study, solid microspheres and DWMS were fabricated using a surface-eroding polymer (poly[1,6-bis(p-carboxyphenoxy)hexane]; PCPH) and a bulk-eroding polymer (poly(D,L-lactide-co-glycolide); PLG). Erosion of the particles was observed by optical and electron microscopy, while polymer degradation was followed by gel permeation chromatography, during incubation in buffer at 37 degrees C. Degradation and erosion were very different depending on which polymer formed the particle shell. Nevertheless, the relatively thin (approximately 5 microm) PCPH shells could not prevent water penetration, and the PLG cores completely eroded by 6 weeks of incubation.
Collapse
Affiliation(s)
- Emily J Pollauf
- Department of Chemical and Biomolecular Engineering, University of Illinois, Box C-3, 600 S. Mathews Ave., Urbana, IL 61801, USA
| | | | | | | |
Collapse
|