1
|
Chelstrom BP, Chawla D, Henak CR. Failure in articular cartilage: Finite element predictions of stress, strain, and pressure under micro-indentation induced fracture. J Mech Behav Biomed Mater 2024; 150:106300. [PMID: 38104488 DOI: 10.1016/j.jmbbm.2023.106300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/31/2023] [Accepted: 12/02/2023] [Indexed: 12/19/2023]
Abstract
Articular cartilage is found at the distal end of long bones and is responsible for assisting in joint articulation. While articular cartilage has remarkable resistance to failure, once initially damaged, degeneration is nearly irreversible. Thus, understanding damage initiation is important. There are a few proposed mechanisms for articular cartilage failure initiation: (A) a single collagen fibril stress-based regime; (B) a rate-dependent regime captured by brittle failure at slow displacement rates (SDR) and ductile failure at fast displacement rates (FDR); and (C) a rate-dependent regime where failure is governed by pressurization fragmentation at SDR and governed by strain at FDR. The objective of this study was to use finite element (FE) models to provide evidence to support or refute these proposed failure mechanisms. Models were developed of microfracture experiments that investigated osmolarity (hypo-osmolar, normal osmolarity, and hyper-osmolar) and displacement rate (FDR and SDR) effects. Cartilage was modeled with a neo-Hookean ground matrix, strain-dependent permeability, nonlinear fibril reinforcement with viscoelastic fibril terms, and Donnan equilibrium swelling. Total stress, solid matrix stress, Lagrange strain, and fluid pressure were determined under the indenter tip at the moment of microfracture. Results indicated significant rate dependence across multiple outputs, which does not support (A) a single failure regime. Larger solid and fluid pressures at FDR than SDR did not support (C) a rate-dependent regime split by pressurization at SDR and strain at FDR. Consistent solid shear stresses at SDR and consistent third principal solid stresses at FDR support (B) the ductile-brittle failure regime. These findings help to shed light on the underlying mechanisms of articular cartilage failure, which have implications for the development of osteoarthritis.
Collapse
Affiliation(s)
- Brandon P Chelstrom
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Dipul Chawla
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Corinne R Henak
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
2
|
Chawla D, Eriten M, Henak CR. Effect of osmolarity and displacement rate on cartilage microfracture clusters failure into two regimes. J Mech Behav Biomed Mater 2022; 136:105467. [PMID: 36198233 DOI: 10.1016/j.jmbbm.2022.105467] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 08/16/2022] [Accepted: 09/12/2022] [Indexed: 11/22/2022]
Abstract
Articular cartilage is a poroviscoelastic (PVE) material with remarkable resistance to fracture and fatigue failure. Cartilage failure mechanisms and material properties that govern failure are incompletely understood. Because cartilage is partially comprised of negatively charged glycosaminoglycans, altering solvent osmolarity can influence PVE relaxations. Therefore, this study aims to use osmolarity as a tool to provide additional data to interpret the role of PVE relaxations and identify cartilage failure regimes. Cartilage fracture was induced using a 100 μm radius spheroconical indenter at controlled displacement rates under three different osmolarity solvents. Secondarily, contact pressure (CP) and strain energy density (SED) were estimated to cluster data into two failure regimes with an expectation maximization algorithm. Critical displacement, critical load, critical time, and critical work to fracture increased with increasing osmolarity at a slow displacement rate whereas no significant effect was observed at a fast displacement rate. Clustering provided two distinct failure regimes, with regime (I) at lower normalized thickness (contact radius divided by sample thickness), and regime (II) at higher normalized thickness. Varied CP and SED in regime (I) suggest that failure in the regime is strain-governed. Constant CP and SED in regime (II) suggests that failure in the regime is dominantly governed by stress. These regimes can be interpreted as ductile versus brittle, or using a pressurized fragmentation interpretation. These findings demonstrated fundamental failure properties and postulate failure regimes for articular cartilage.
Collapse
Affiliation(s)
- Dipul Chawla
- Department of Mechanical Engineering, University of Wisconsin-Madison, 1513 University Ave., Madison, WI, 53706, USA
| | - Melih Eriten
- Department of Mechanical Engineering, University of Wisconsin-Madison, 1513 University Ave., Madison, WI, 53706, USA
| | - Corinne R Henak
- Department of Mechanical Engineering, University of Wisconsin-Madison, 1513 University Ave., Madison, WI, 53706, USA; Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 University Ave., Madison, WI, 53706, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, 1111 Highland Ave., Madison, WI, 53705, USA.
| |
Collapse
|
3
|
Hwang JW, Chawla D, Han G, Eriten M, Henak CR. Effects of solvent osmolarity and viscosity on cartilage energy dissipation under high-frequency loading. J Mech Behav Biomed Mater 2021; 126:105014. [PMID: 34871958 DOI: 10.1016/j.jmbbm.2021.105014] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/29/2021] [Accepted: 11/27/2021] [Indexed: 01/16/2023]
Abstract
Articular cartilage is a spatially heterogeneous, dissipative biological hydrogel with a high fluid volume fraction. Although energy dissipation is important in the context of delaying cartilage damage, the dynamic behavior of articular cartilage equilibrated in media of varied osmolarity and viscosity is not widely understood. This study investigated the mechanical behaviors of cartilage when equilibrated to media of varying osmolarity and viscosity. Dynamic moduli and phase shift were measured at both low (1 Hz) and high (75-300 Hz) frequency, with cartilage samples compressed to varied offset strain levels. Increasing solution osmolarity and viscosity both independently resulted in larger energy dissipation and decreased dynamic modulus of cartilage at both low and high frequency. Mechanical property alterations induced by varying osmolarity are likely due to the change in permeability and fluid volume fraction within the tissue. The effects of solution viscosity are likely due to frictional interactions at the solid-fluid interface, affecting energy dissipation. These findings highlight the significance of interstitial fluid on the energy dissipation capabilities of the tissue, which can influence the onset of cartilage damage.
Collapse
Affiliation(s)
- Jin Wook Hwang
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Dipul Chawla
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Guebum Han
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Melih Eriten
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Corinne R Henak
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
4
|
Babaei B, Velasquez-Mao AJ, Pryse KM, McConnaughey WB, Elson EL, Genin GM. Energy dissipation in quasi-linear viscoelastic tissues, cells, and extracellular matrix. J Mech Behav Biomed Mater 2018; 84:198-207. [PMID: 29793157 PMCID: PMC5995675 DOI: 10.1016/j.jmbbm.2018.05.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/01/2018] [Accepted: 05/07/2018] [Indexed: 11/16/2022]
Abstract
Characterizing how a tissue's constituents give rise to its viscoelasticity is important for uncovering how hidden timescales underlie multiscale biomechanics. These constituents are viscoelastic in nature, and their mechanics must typically be assessed from the uniaxial behavior of a tissue. Confounding the challenge is that tissue viscoelasticity is typically associated with nonlinear elastic responses. Here, we experimentally assessed how fibroblasts and extracellular matrix (ECM) within engineered tissue constructs give rise to the nonlinear viscoelastic responses of a tissue. We applied a constant strain rate, "triangular-wave" loading and interpreted responses using the Fung quasi-linear viscoelastic (QLV) material model. Although the Fung QLV model has several well-known weaknesses, it was well suited to the behaviors of the tissue constructs, cells, and ECM tested. Cells showed relatively high damping over certain loading frequency ranges. Analysis revealed that, even in cases where the Fung QLV model provided an excellent fit to data, the the time constant derived from the model was not in general a material parameter. Results have implications for design of protocols for the mechanical characterization of biological materials, and for the mechanobiology of cells within viscoelastic tissues.
Collapse
Affiliation(s)
- Behzad Babaei
- Neuroscience Research Australia, Randwick, Australia
| | - A J Velasquez-Mao
- UC Berkeley and UC San Francisco Graduate Program in Bioengineering, San Francisco, CA, USA
| | - Kenneth M Pryse
- Department of Biochemistry & Molecular Biophysics, Washington University School of Medicine, St. Louis, MO, USA
| | - William B McConnaughey
- Department of Biochemistry & Molecular Biophysics, Washington University School of Medicine, St. Louis, MO, USA
| | - Elliot L Elson
- Department of Biochemistry & Molecular Biophysics, Washington University School of Medicine, St. Louis, MO, USA
| | - Guy M Genin
- NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, St. Louis, MO, USA.
| |
Collapse
|
5
|
Wiig H, Luft FC, Titze JM. The interstitium conducts extrarenal storage of sodium and represents a third compartment essential for extracellular volume and blood pressure homeostasis. Acta Physiol (Oxf) 2018; 222. [PMID: 29193764 DOI: 10.1111/apha.13006] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 10/31/2017] [Accepted: 11/23/2017] [Indexed: 12/15/2022]
Abstract
The role of salt in the pathogenesis of arterial hypertension is not well understood. According to the current understanding, the central mechanism for blood pressure (BP) regulation relies on classical studies linking BP and Na+ balance, placing the kidney at the very centre of long-term BP regulation. To maintain BP homeostasis, the effective circulating fluid volume and thereby body Na+ content has to be maintained within very narrow limits. From recent work in humans and rats, the notion has emerged that Na+ could be stored somewhere in the body without commensurate water retention to buffer free extracellular Na+ and that previously unidentified extrarenal, tissue-specific regulatory mechanisms are operative regulating the release and storage of Na+ from a kidney-independent reservoir. Moreover, immune cells from the mononuclear phagocyte system not only function as local on-site sensors of interstitial electrolyte concentration, but also, together with lymphatics, act as systemic regulators of body fluid volume and BP. These studies have established new and unexpected targets in studies of BP control and thus the pathophysiology of hypertension: the interstitium/extracellular matrix of the skin, its inherent interstitial fluid and the lymphatic vasculature forming a vessel network in the interstitium. Aspects of the interstitium in relation to Na+ balance and hypertension are the focus of this review. Taken together, observations of salt storage in the skin to buffer free extracellular Na+ and macrophage modulation of the extracellular matrix and lymphatics suggest that electrolyte homeostasis in the body cannot be achieved by renal excretion alone, but also relies on extrarenal regulatory mechanisms.
Collapse
Affiliation(s)
- H. Wiig
- Department of Biomedicine; University of Bergen; Bergen Norway
| | - F. C. Luft
- Experimental and Clinical Research Center; Max-Delbrück Center for Molecular Medicine; Charité Medical Faculty; Berlin Germany
- Division of Clinical Pharmacology; Department of Medicine; Vanderbilt University School of Medicine; Nashville TN USA
| | - J. M. Titze
- Division of Clinical Pharmacology; Department of Medicine; Vanderbilt University School of Medicine; Nashville TN USA
| |
Collapse
|
6
|
Kerch G. Polymer hydration and stiffness at biointerfaces and related cellular processes. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2018; 14:13-25. [DOI: 10.1016/j.nano.2017.08.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 08/14/2017] [Accepted: 08/16/2017] [Indexed: 01/15/2023]
|
7
|
Inamdar SR, Knight DP, Terrill NJ, Karunaratne A, Cacho-Nerin F, Knight MM, Gupta HS. The Secret Life of Collagen: Temporal Changes in Nanoscale Fibrillar Pre-Strain and Molecular Organization during Physiological Loading of Cartilage. ACS NANO 2017; 11:9728-9737. [PMID: 28800220 DOI: 10.1021/acsnano.7b00563] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Articular cartilage is a natural biomaterial whose structure at the micro- and nanoscale is critical for healthy joint function and where degeneration is associated with widespread disorders such as osteoarthritis. At the nanoscale, cartilage mechanical functionality is dependent on the collagen fibrils and hydrated proteoglycans that form the extracellular matrix. The dynamic response of these ultrastructural building blocks at the nanoscale, however, remains unclear. Here we measure time-resolved changes in collagen fibril strain, using small-angle X-ray diffraction during compression of bovine and human cartilage explants. We demonstrate the existence of a collagen fibril tensile pre-strain, estimated from the D-period at approximately 1-2%, due to osmotic swelling pressure from the proteoglycan. We reveal a rapid reduction and recovery of this pre-strain which occurs during stress relaxation, approximately 60 s after the onset of peak load. Furthermore, we show that this reduction in pre-strain is linked to disordering in the intrafibrillar molecular packing, alongside changes in the axial overlapping of tropocollagen molecules within the fibril. Tissue degradation in the form of selective proteoglycan removal disrupts both the collagen fibril pre-strain and the transient response during stress relaxation. This study bridges a fundamental gap in the knowledge describing time-dependent changes in collagen pre-strain and molecular organization that occur during physiological loading of articular cartilage. The ultrastructural details of this transient response are likely to transform our understanding of the role of collagen fibril nanomechanics in the biomechanics of cartilage and other hydrated soft tissues.
Collapse
Affiliation(s)
- Sheetal R Inamdar
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London , London E1 4NS, United Kingdom
| | - David P Knight
- Orthox Ltd. , 66 Innovation Drive, Milton Park, Abingdon OX14 4RQ, United Kingdom
| | - Nicholas J Terrill
- Harwell Science and Innovation Campus, Diamond Light Source , Harwell, Didcot OX11 0DE, United Kingdom
| | - Angelo Karunaratne
- Department of Bioengineering, Imperial College London , London SW7 2AZ, United Kingdom
| | - Fernando Cacho-Nerin
- Harwell Science and Innovation Campus, Diamond Light Source , Harwell, Didcot OX11 0DE, United Kingdom
| | - Martin M Knight
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London , London E1 4NS, United Kingdom
| | - Himadri S Gupta
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London , London E1 4NS, United Kingdom
| |
Collapse
|
8
|
Osmotically driven membrane processes: Exploring the potential of branched polyethyleneimine as draw solute using porous FO membranes with NF separation layers. J Memb Sci 2016. [DOI: 10.1016/j.memsci.2016.02.041] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Behzadi S, Rosenauer C, Kappl M, Mohr K, Landfester K, Crespy D. Osmotic pressure-dependent release profiles of payloads from nanocontainers by co-encapsulation of simple salts. NANOSCALE 2016; 8:12998-13005. [PMID: 27304251 DOI: 10.1039/c6nr01882c] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The encapsulation of payloads in micro- to nano-scale capsules allows protection of the payload from the surrounding environment and control of its release profile. Herein, we program the release of hydrophilic payloads from nanocontainers by co-encapsulating simple inorganic salts for adjusting the osmotic pressure. The latter either leads to a burst release at high concentrations of co-encapsulated salts or a sustained release at lower concentrations. Osmotic pressure causes swelling of the nanocapsule's shell and therefore sustained release profiles can be adjusted by crosslinking it. The approach presented allows for programing the release of payloads by co-encapsulating inexpensive salts inside nanocontainers without the help of stimuli-responsive materials.
Collapse
Affiliation(s)
- Shahed Behzadi
- Max Planck Institute for Polymer Research, D-55128 Mainz, Germany.
| | | | | | | | | | | |
Collapse
|
10
|
Remodeling by fibroblasts alters the rate-dependent mechanical properties of collagen. Acta Biomater 2016; 37:28-37. [PMID: 27015891 DOI: 10.1016/j.actbio.2016.03.034] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Revised: 03/18/2016] [Accepted: 03/21/2016] [Indexed: 12/18/2022]
Abstract
UNLABELLED The ways that fibroblasts remodel their environment are central to wound healing, development of musculoskeletal tissues, and progression of pathologies such as fibrosis. However, the changes that fibroblasts make to the material around them and the mechanical consequences of these changes have proven difficult to quantify, especially in realistic, viscoelastic three-dimensional culture environments, leaving a critical need for quantitative data. Here, we observed the mechanisms and quantified the mechanical effects of fibroblast remodeling in engineered tissue constructs (ETCs) comprised of reconstituted rat tail (type I) collagen and human fibroblast cells. To study the effects of remodeling on tissue mechanics, stress-relaxation tests were performed on ETCs cultured for 24, 48, and 72h. ETCs were treated with deoxycholate and tested again to assess the ECM response. Viscoelastic relaxation spectra were obtained using the generalized Maxwell model. Cells exhibited viscoelastic damping at two finite time constants over which the ECM showed little damping, approximately 0.2s and 10-30s. Different finite time constants in the range of 1-7000s were attributed to ECM relaxation. Cells remodeled the ECM to produce a relaxation time constant on the order of 7000s, and to merge relaxation finite time constants in the 0.5-2s range into a single time content in the 1s range. Results shed light on hierarchical deformation mechanisms in tissues, and on pathologies related to collagen relaxation such as diastolic dysfunction. STATEMENT OF SIGNIFICANCE As fibroblasts proliferate within and remodel a tissue, they change the tissue mechanically. Quantifying these changes is critical for understanding wound healing and the development of pathologies such as cardiac fibrosis. Here, we characterize for the first time the spectrum of viscoelastic (rate-dependent) changes arising from the remodeling of reconstituted collagen by fibroblasts. The method also provides estimates of the viscoelastic spectra of fibroblasts within a three-dimensional culture environment. Results are of particular interest because of the ways that fibroblasts alter the mechanical response of collagen at loading frequencies associated with cardiac contraction in humans.
Collapse
|
11
|
June RK, Fyhrie DP. A comparison of cartilage stress-relaxation models in unconfined compression: QLV and stretched exponential in combination with fluid flow. Comput Methods Biomech Biomed Engin 2013; 16:565-76. [DOI: 10.1080/10255842.2011.629612] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
12
|
Xu B, Li H, Zhang Y. Understanding the viscoelastic behavior of collagen matrices through relaxation time distribution spectrum. BIOMATTER 2013; 3:24651. [PMID: 23628869 PMCID: PMC3749280 DOI: 10.4161/biom.24651] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
This study aims to provide understanding of the macroscopic viscoelastic behavior of collagen matrices through studying the relaxation time distribution spectrum obtained from stress relaxation tests. Hydrated collagen gel and dehydrated collagen thin film was exploited as two different hydration levels of collagen matrices. Genipin solution was used to induce crosslinking in collagen matrices. Biaxial stress relaxation tests were performed to characterize the viscoelastic behavior of collagen matrices. The rate of stress relaxation of both hydrated and dehydrated collagen matrices shows a linear initial stress level dependency. Increased crosslinking reduces viscosity in collagen gel, but the effect is negligible for thin film. Relaxation time distribution spectrum was obtained from the stress relaxation data by inverse Laplace transform. For most of the collagen matrices, three peaks at the short (0.3s ~1 s), medium (3s ~90 s), and long relaxation time (> 200 s) were observed in the continuous spectrum, which likely corresponds to relaxation mechanisms involve fiber, inter-fibril, and fibril sliding. Splitting of the middle peak was observed at higher initial stress levels suggesting increased structural heterogeneity at the fibril level with mechanical loading. The intensity of the long-term peaks increases with higher initial stress levels indicating the engagement of collagen fibrils at higher levels of tissue strain.
Collapse
Affiliation(s)
- Bin Xu
- Department of Mechanical Engineering; Boston University; Boston, MA USA
| | - Haiyue Li
- Department of Mechanical Engineering; Boston University; Boston, MA USA
| | - Yanhang Zhang
- Department of Mechanical Engineering; Boston University; Boston, MA USA; Department of Biomedical Engineering; Boston University; Boston, MA USA
| |
Collapse
|
13
|
Sivan SS, Merkher Y, Wachtel E, Urban JPG, Lazary A, Maroudas A. A needle micro-osmometer for determination of glycosaminoglycan concentration in excised nucleus pulposus tissue. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2013; 22:1765-73. [PMID: 23417062 DOI: 10.1007/s00586-013-2714-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2012] [Revised: 02/03/2013] [Accepted: 02/04/2013] [Indexed: 01/08/2023]
Abstract
PURPOSE Aggrecan is one of the major macromolecular components of the intervertebral disc (IVD) and its loss is an early sign of degeneration. Restoration of aggrecan, and hence of biomechanical properties, is a major objective of biological therapies. At present, assessment of aggrecan concentration via its glycosaminoglycan (GAG) content is accomplished using biochemical and histological methods which require sacrifice of tissue. A minimally invasive method for assessing GAG, and hence aggrecan, which can avoid destruction of tissue, would be of benefit. METHODS We have developed a needle micro-osmometer that is capable of measuring flux of saline into excised human nucleus pulposus (NP) tissue. Using the isotropic osmotic stress technique to assess the swelling pressure of the excised NP tissue and assuming negligible collagen tensile stress, we were able to relate the flux to the tissue fixed charge density (FCD). GAG concentration is evaluated from its FCD via the radioactive tracer technique. Samples representing different ages (28-59 years) and degeneration grades (1-4) were analyzed. RESULTS The flux is controlled by both the osmotic pressure difference across the probe's semi-permeable membrane and by the tissue permeability. A linear correlation was found between flux and the tissue FCD. The equation describing the linear fit is FCD/(total tissue hydration) = 1.97 × 10(-4) + 8283 × flux (R = 0.836, p < 10(-4)). Thus, by measuring saline flux, the concentration of GAG can be determined. CONCLUSIONS Micro-osmometry provides a reliable and minimally invasive tool for assessing GAG content in excised NP tissue. This method may be usefully applied in tissue engineering applications. It may also be useful for in vivo measurements if the question of the degenerative effect of needle puncture can be overcome.
Collapse
Affiliation(s)
- Sarit Sara Sivan
- Department of Biomedical Engineering, Technion, Israel Institute of Technology, IIT, 32000 Haifa, Israel.
| | | | | | | | | | | |
Collapse
|
14
|
Mahmoud H, Wagoner Johnson A, Chien EK, Poellmann MJ, McFarlin B. System-level biomechanical approach for the evaluation of term and preterm pregnancy maintenance. J Biomech Eng 2013; 135:021009. [PMID: 23445054 PMCID: PMC3705860 DOI: 10.1115/1.4023486] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Revised: 01/20/2013] [Accepted: 11/28/2013] [Indexed: 01/08/2023]
Abstract
Preterm birth is the primary contributor to perinatal morbidity and mortality, with those born prior to 32 weeks disproportionately contributing compared to those born at 32-37 weeks. Outcomes for babies born prematurely can be devastating. Parturition is recognized as a mechanical process that involves the two processes that are required to initiate labor: rhythmic myometrial contractions and cervical remodeling with subsequent dilation. Studies of parturition tend to separate these two processes rather than evaluate them as a unified system. The mechanical property characterization of the cervix has been primarily performed on isolated cervical tissue, with an implied understanding of the contribution from the uterine corpus. Few studies have evaluated the function of the uterine corpus in the absence of myometrial contractions or in relationship to retaining the fetus. Therefore, the cervical-uterine interaction has largely been neglected in the literature. We suggest that a system-level biomechanical approach is needed to understand pregnancy maintenance. To that end, this paper has two main goals. One goal is to highlight the gaps in current knowledge that need to be addressed in order to develop any comprehensive and clinically relevant models of the system. The second goal is to illustrate the utility of finite element models in understanding pregnancy maintenance of the cervical-uterine system. The paper targets an audience that includes the reproductive biologist/clinician and the engineer/physical scientist interested in biomechanics and the system level behavior of tissues.
Collapse
Affiliation(s)
- Hussam Mahmoud
- Department of Civil and Environmental Engineering, College of Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | | | | | | | | |
Collapse
|
15
|
Mroue KH, MacKinnon N, Xu J, Zhu P, McNerny E, Kohn DH, Morris MD, Ramamoorthy A. High-resolution structural insights into bone: a solid-state NMR relaxation study utilizing paramagnetic doping. J Phys Chem B 2012; 116:11656-61. [PMID: 22953757 PMCID: PMC3460063 DOI: 10.1021/jp307935g] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The hierarchical heterogeneous architecture of bone imposes significant challenges to structural and dynamic studies conducted by traditional biophysical techniques. High-resolution solid-state nuclear magnetic resonance (SSNMR) spectroscopy is capable of providing detailed atomic-level structural insights into such traditionally challenging materials. However, the relatively long data-collection time necessary to achieve a reliable signal-to-noise ratio (S/N) remains a major limitation for the widespread application of SSNMR on bone and related biomaterials. In this study, we attempt to overcome this limitation by employing the paramagnetic relaxation properties of copper(II) ions to shorten the (1)H intrinsic spin-lattice (T(1)) relaxation times measured in natural-abundance (13)C cross-polarization (CP) magic-angle-spinning (MAS) NMR experiments on bone tissues for the purpose of accelerating the data acquisition time in SSNMR. To this end, high-resolution solid-state (13)C CPMAS experiments were conducted on type I collagen (bovine tendon), bovine cortical bone, and demineralized bovine cortical bone, each in powdered form, to measure the (1)H T(1) values in the absence and in the presence of 30 mM Cu(II)(NH(4))(2)EDTA. Our results show that the (1)H T(1) values were successfully reduced by a factor of 2.2, 2.9, and 3.2 for bovine cortical bone, type I collagen, and demineralized bone, respectively, without reducing the spectral resolution and thus enabling faster data acquisition. In addition, paramagnetic quenching of particular (13)C NMR resonances on exposure to Cu(2+) ions in the absence of mineral was also observed, potentially suggesting the relative proximity of three main amino acids in the protein backbone (glycine, proline, and alanine) to the bone mineral surface.
Collapse
Affiliation(s)
- Kamal H. Mroue
- Biophysics, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
- Department of Chemistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - Neil MacKinnon
- Biophysics, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
- Department of Chemistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - Jiadi Xu
- Biophysics, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
- Department of Chemistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - Peizhi Zhu
- Department of Chemistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - Erin McNerny
- School of Dentistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - David H. Kohn
- School of Dentistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - Michael D. Morris
- Department of Chemistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| | - Ayyalusamy Ramamoorthy
- Biophysics, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
- Department of Chemistry, The University of Michigan, Ann Arbor, Michigan, 48109-1055, USA
| |
Collapse
|
16
|
Wiig H, Swartz MA. Interstitial Fluid and Lymph Formation and Transport: Physiological Regulation and Roles in Inflammation and Cancer. Physiol Rev 2012; 92:1005-60. [PMID: 22811424 DOI: 10.1152/physrev.00037.2011] [Citation(s) in RCA: 447] [Impact Index Per Article: 37.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
The interstitium describes the fluid, proteins, solutes, and the extracellular matrix (ECM) that comprise the cellular microenvironment in tissues. Its alterations are fundamental to changes in cell function in inflammation, pathogenesis, and cancer. Interstitial fluid (IF) is created by transcapillary filtration and cleared by lymphatic vessels. Herein we discuss the biophysical, biomechanical, and functional implications of IF in normal and pathological tissue states from both fluid balance and cell function perspectives. We also discuss analysis methods to access IF, which enables quantification of the cellular microenvironment; such methods have demonstrated, for example, that there can be dramatic gradients from tissue to plasma during inflammation and that tumor IF is hypoxic and acidic compared with subcutaneous IF and plasma. Accumulated recent data show that IF and its convection through the interstitium and delivery to the lymph nodes have many and diverse biological effects, including in ECM reorganization, cell migration, and capillary morphogenesis as well as in immunity and peripheral tolerance. This review integrates the biophysical, biomechanical, and biological aspects of interstitial and lymph fluid and its transport in tissue physiology, pathophysiology, and immune regulation.
Collapse
Affiliation(s)
- Helge Wiig
- Department of Biomedicine, University of Bergen, Bergen, Norway; and Laboratory of Lymphatic and Cancer Bioengineering, Institute of Bioengineering and Swiss Institute for Experimental Cancer Research, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Melody A. Swartz
- Department of Biomedicine, University of Bergen, Bergen, Norway; and Laboratory of Lymphatic and Cancer Bioengineering, Institute of Bioengineering and Swiss Institute for Experimental Cancer Research, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
17
|
Ganguly K, McRury ID, Goodwin PM, Morgan RE, Augé WK. Targeted In Situ Biosynthetic Transcriptional Activation in Native Surface-Level Human Articular Chondrocytes during Lesion Stabilization. Cartilage 2012; 3:141-55. [PMID: 26069627 PMCID: PMC4297128 DOI: 10.1177/1947603511426881] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE Safe articular cartilage lesion stabilization is an important early surgical intervention advance toward mitigating articular cartilage disease burden. While short-term chondrocyte viability and chondrosupportive matrix modification have been demonstrated within tissue contiguous to targeted removal of damaged articular cartilage, longer term tissue responses require evaluation to further clarify treatment efficacy. The purpose of this study was to examine surface chondrocyte responses within contiguous tissue after lesion stabilization. METHODS Nonablation radiofrequency lesion stabilization of human cartilage explants obtained during knee replacement was performed for surface fibrillation. Time-dependent chondrocyte viability, nuclear morphology and cell distribution, and temporal response kinetics of matrix and chaperone gene transcription indicative of differentiated chondrocyte function were evaluated in samples at intervals to 96 hours after treatment. RESULTS Subadjacent surface articular cartilage chondrocytes demonstrated continued viability for 96 hours after treatment, a lack of increased nuclear fragmentation or condensation, persistent nucleic acid production during incubation reflecting cellular assembly behavior, and transcriptional up-regulation of matrix and chaperone genes indicative of retained biosynthetic differentiated cell function. CONCLUSIONS The results of this study provide further evidence of treatment efficacy and suggest the possibility to manipulate or induce cellular function, thereby recruiting local chondrocytes to aid lesion recovery. Early surgical intervention may be viewed as a tissue rescue, allowing articular cartilage to continue displaying biological responses appropriate to its function rather than converting to a tissue ultimately governed by the degenerative material property responses of matrix failure. Early intervention may positively impact the late changes and reduce disease burden of damaged articular cartilage.
Collapse
Affiliation(s)
| | | | | | | | - Wayne K. Augé
- NuOrtho Surgical Inc., Fall River, MA, USA,Center for Orthopaedic and Sports Performance Research Inc., Santa Fe, NM, USA
| |
Collapse
|
18
|
Nguyen AM, Levenston ME. Comparison of osmotic swelling influences on meniscal fibrocartilage and articular cartilage tissue mechanics in compression and shear. J Orthop Res 2012; 30:95-102. [PMID: 21735474 DOI: 10.1002/jor.21493] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2011] [Accepted: 06/12/2011] [Indexed: 02/04/2023]
Abstract
Although the contribution of the circumferential collagen bundles to the anisotropic tensile stiffness of meniscal tissue has been well described, the implications of interactions between tissue components for other mechanical properties have not been as widely examined. This study compared the effects of the proteoglycan-associated osmotic swelling stress on meniscal fibrocartilage and articular cartilage (AC) mechanics by manipulating the osmotic environment and tissue compressive offset. Cylindrical samples were obtained from the menisci and AC of bovine stifles, equilibrated in phosphate-buffered saline solutions ranging from 0.1× to 10×, and tested in oscillatory torsional shear and unconfined compression. Biochemical analysis indicated that treatments and testing did not substantially alter tissue composition. Mechanical testing revealed tissue-specific responses to both increasing compressive offset and decreasing bath salinity. Most notably, reduced salinity dramatically increased the shear modulus of both axially and circumferentially oriented meniscal tissue explants to a much greater extent than for cartilage samples. Combined with previous studies, these findings suggest that meniscal proteoglycans have a distinct structural role, stabilizing, and stiffening the matrix surrounding the primary circumferential collagen bundles.
Collapse
Affiliation(s)
- An M Nguyen
- Department of Mechanical Engineering, Stanford University, Stanford, CA, USA
| | | |
Collapse
|
19
|
Lim A, Protsenko DE, Wong BJF. Changes in the tangent modulus of rabbit septal and auricular cartilage following electromechanical reshaping. J Biomech Eng 2011; 133:094502. [PMID: 22010748 PMCID: PMC3705892 DOI: 10.1115/1.4004916] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2011] [Revised: 08/17/2011] [Indexed: 11/08/2022]
Abstract
Transforming decades' old methodology, electromechanical reshaping (EMR) may someday replace traditionally destructive surgical techniques with a less invasive means of cartilage reshaping for reconstructive and esthetic facial surgery. Electromechanical reshaping is essentially accomplished through the application of voltage to a mechanically deformed cartilage specimen. While the capacity of the method for effective reshaping has been consistently shown, its associated effects on cartilage mechanical properties are not fully comprehended. To begin to explore the mechanical effect of EMR on cartilage, the tangent moduli of EMR-treated rabbit septal and auricular cartilage were calculated and compared to matched control values. Between the two main EMR parameters, voltage and application time, the former was varied from 2-8 V and the latter held constant at 2 min for septal cartilage, 3 min for auricular cartilage. Flat platinum electrodes were used to apply voltage, maintaining the flatness of the specimens for more precise mechanical testing through a uniaxial tension test of constant strain rate 0.01 mm/s. Above 2 V, both septal and auricular cartilage demonstrated a slight reduction in stiffness, quantified by the tangent modulus. A thermal effect was observed above 5 V, a newly identified EMR application threshold to avoid the dangers associated with thermoforming cartilage. Optimizing EMR application parameters and understanding various side effects bridge the gap between EMR laboratory research and clinical use, and the knowledge acquired through this mechanical study may be one additional support for that bridge.
Collapse
Affiliation(s)
- Amanda Lim
- Department of Biomedical Engineering,The Beckman Laser Institute and Medical Clinic,University of California, Irvine,Irvine, CA 92697e-mail:
| | - Dmitry E. Protsenko
- The Beckman Laser Institute and Medical Clinic,University of California, Irvine,1002 Health Sciences Road,Irvine, CA 92612e-mail:
| | - Brian J. F. Wong
- Department of Otolaryngology, Head and Neck Surgeryand Department of Biomedical Engineering,The Beckman Laser Institute and Medical Clinic,University of California, Irvine,1002 Health Sciences Road,Irvine, CA 92612e-mail:
| |
Collapse
|
20
|
Hwang D, Gabai AS, Yu M, Yew AG, Hsieh AH. Role of load history in intervertebral disc mechanics and intradiscal pressure generation. Biomech Model Mechanobiol 2011; 11:95-106. [PMID: 21380846 DOI: 10.1007/s10237-011-0295-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2010] [Accepted: 02/03/2011] [Indexed: 11/25/2022]
Abstract
Solid-fluid interactions play an important role in mediating viscoelastic behaviour of biological tissues. In the intervertebral disc, water content is governed by a number of factors, including age, disease and mechanical loads, leading to changes in stiffness characteristics. We hypothesized that zonal stress distributions depend on load history, or the prior stresses experienced by the disc. To investigate these effects, rat caudal motion segments were subjected to compressive creep biomechanical testing in vitro using a protocol that consisted of two phases: a Prestress Phase (varied to represent different histories of load) followed immediately by an Exertion Phase, identical across all Prestress groups. Three analytical models were used to fit the experimental data in order to evaluate load history effects on gross and zonal disc mechanics. Model results indicated that while gross transient response was insensitive to load history, there may be changes in the internal mechanics of the disc. In particular, a fluid transport model suggested that the role of the nucleus pulposus in resisting creep during Exertion depended on Prestress conditions. Separate experiments using similarly defined load history regimens were performed to verify these predictions by measuring intradiscal pressure with a fibre optic sensor. We found that the ability for intradiscal pressure generation was load history-dependent and exhibited even greater sensitivity than predicted by analytical models. A 0.5 MPa Exertion load resulted in 537.2 kPa IDP for low magnitude Prestress compared with 373.7 kPa for high magnitude Prestress. Based on these measurements, we developed a simple model that may describe the pressure-shear environment in the nucleus pulposus. These findings may have important implications on our understanding of how mechanical stress contributes to disc health and disease etiology.
Collapse
Affiliation(s)
- David Hwang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | | | | | | | | |
Collapse
|
21
|
June RK, Fyhrie DP. Temperature effects in articular cartilage biomechanics. ACTA ACUST UNITED AC 2011; 213:3934-40. [PMID: 21037073 DOI: 10.1242/jeb.042960] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Articular cartilage is the soft tissue that covers contacting surfaces of bones in synovial joints. Cartilage is composed of chondrocytes and an extracellular matrix containing numerous biopolymers, cations and water. Healthy cartilage functions biomechanically to provide smooth and stable joint movement. Degenerative joint diseases such as osteoarthritis involve cartilage deterioration, resulting in painful and cumbersome joint motion. Temperature is a fundamental quantity in mechanics, yet the effects of temperature on cartilage mechanical behavior are unknown. This study addressed the questions of whether cartilage stiffness and stress relaxation change with temperature. Samples of middle-zone bovine calf patellofemoral cartilage were tested in unconfined compression first at 24°C and then again after heating to 60°C. The data reveal that when temperature increases: (1) both peak and equilibrium stiffness increase by 150 and 8%, respectively, and (2) stress relaxation is faster at higher temperature, as shown by a 60% decrease in the time constant. The increases in temperature-dependent stiffness are consistent with polymeric mechanisms of matrix viscoelasticity but not with interstitial fluid flow. The changes in the time constant are consistent with a combination of both fluid flow and matrix viscoelasticity. Furthermore, we discovered a novel phenomenon: at stress-relaxation equilibrium, compressive stress increased with temperature. These data demonstrate a rich area of cartilage mechanics that has previously been unexplored and emphasize the role of polymer dynamics in cartilage viscoelasticity. Further studies of cartilage polymer dynamics may yield additional insight into mechanisms of cartilage material behavior that could improve treatments for cartilage degeneration.
Collapse
Affiliation(s)
- Ronald K June
- University of California, San Diego, Department of Cellular and Molecular Medicine, La Jolla, CA 92093-0686, USA.
| | | |
Collapse
|
22
|
Suprastructures of extracellular matrices: paradigms of functions controlled by aggregates rather than molecules. Cell Tissue Res 2009; 339:7-18. [DOI: 10.1007/s00441-009-0864-0] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2009] [Accepted: 08/11/2009] [Indexed: 01/17/2023]
|
23
|
Ateshian GA, Rajan V, Chahine NO, Canal CE, Hung CT. Modeling the matrix of articular cartilage using a continuous fiber angular distribution predicts many observed phenomena. J Biomech Eng 2009; 131:061003. [PMID: 19449957 DOI: 10.1115/1.3118773] [Citation(s) in RCA: 136] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cartilage is a hydrated soft tissue whose solid matrix consists of negatively charged proteoglycans enmeshed within a fibrillar collagen network. Though many aspects of cartilage mechanics are well understood today, most notably in the context of porous media mechanics, there remain a number of responses observed experimentally whose prediction from theory has been challenging. In this study the solid matrix of cartilage is modeled with a continuous fiber angular distribution, where fibers can only sustain tension, swelled by the osmotic pressure of a proteoglycan ground matrix. It is shown that this representation of cartilage can predict a number of observed phenomena in relation to the tissue's equilibrium response to mechanical and osmotic loading, when flow-dependent and flow-independent viscoelastic effects have subsided. In particular, this model can predict the transition of Poisson's ratio from very low values in compression (approximately 0.02) to very high values in tension (approximately 2.0). Most of these phenomena cannot be explained when using only three orthogonal fiber bundles to describe the tissue matrix, a common modeling assumption used to date. The main picture emerging from this analysis is that the anisotropy of the fibrillar matrix of articular cartilage is intimately dependent on the mechanism of tensed fiber recruitment, in the manner suggested by our recent theoretical study (Ateshian, 2007, ASME J. Biomech. Eng., 129(2), pp. 240-249).
Collapse
Affiliation(s)
- Gerard A Ateshian
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| | | | | | | | | |
Collapse
|
24
|
Doughty MJ, Bergmanson JPG. Use of a Corneal Stroma Perfusion Technique and Transmission Electron Microscopy to Assess Ultrastructural Changes Associated with Exposure to Slightly Acidic pH 5.75 Solutions. Curr Eye Res 2009; 33:45-57. [DOI: 10.1080/02713680701805742] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
25
|
Loret B, Simões FMF. Effects of pH on transport properties of articular cartilages. Biomech Model Mechanobiol 2009; 9:45-63. [PMID: 19418080 DOI: 10.1007/s10237-009-0158-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2008] [Accepted: 04/16/2009] [Indexed: 11/25/2022]
Abstract
Articular cartilages swell and shrink depending on the ionic strength of the electrolyte they are in contact with. This electro-chemo-mechanical coupling is due to the presence of fixed electrical charges on proteoglycans (PGs). In addition, at nonphysiological pH, collagen fibers become charged. Therefore, variation of the pH of the electrolyte has strong implications on the electrical charge of cartilages and, by the same token, on their transport and mechanical properties. Articular cartilages are viewed as three-phase multi-species porous media. The constitutive framework is phrased in the theory of thermodynamics of porous media. Acid-base reactions, as well as calcium binding, are embedded in this framework. Although macroscopic in nature, the model accounts for a number of biochemical details defining collagen and PGs. The change of the electrical charge is due to the binding of hydrogen ions on specific sites of PGs and collagen. Simulations are performed mimicking laboratory experiments where either the ionic strength or the pH of the bath, the cartilage piece is in contact with, is varied. They provide the evolutions of the chemical compositions of mobile ions, of the sites of acid-base reactions and calcium binding, and of the charges of collagen and glycosaminoglycans, at constant volume fraction of water. Emphasis is laid on the effects of pH, ionic strength and calcium binding on the transport properties of cartilages, and, in particular, on the electrical conductivity and electro-osmotic coefficient.
Collapse
Affiliation(s)
- Benjamin Loret
- Laboratoire Sols, Solides, Structures, Institut National Polytechnique de Grenoble, B.P. 53X, 38041, Grenoble Cedex, France.
| | | |
Collapse
|
26
|
Zernia G, Huster D. Collagen dynamics in articular cartilage under osmotic pressure. NMR IN BIOMEDICINE 2006; 19:1010-9. [PMID: 16823903 DOI: 10.1002/nbm.1061] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Cartilage is a complex biological tissue consisting of collagen, proteoglycans and water. The structure and molecular mobility of the collagen component of cartilage were studied by (13)C solid-state NMR spectroscopy as a function of hydration. The hydration level of cartilage was adjusted between fully hydrated ( approximately 80 wt% H(2)O) and highly dehydrated ( approximately 30 wt% H(2)O) using the osmotic stress technique. Thus, the conditions of mechanical load could be simulated and the response of the tissue macromolecules to mechanical stress is reported. From the NMR measurements, the following results were obtained. (i) Measurements of motionally averaged dipolar (1)H-(13)C couplings were carried out to study the segmental mobility in cartilage collagen at full hydration. Backbone segments undergo fast motions with amplitudes of approximately 35 degrees whereas the collagen side-chains are somewhat more mobile with amplitudes between 40 and 50 degrees . In spite of the high water content of cartilage, collagen remains essentially rigid. (ii) No chemical shift changes were observed in (13)C cross-polarization magic angle spinning spectra of cartilage tissue at varying hydration indicating that the collagen structure was not altered by application of high osmotic stress. (iii) The (1)H-(13)C dipolar coupling values detected for collagen signals respond to dehydration. The dipolar coupling values gradually increase upon cartilage dehydration, reaching rigid limit values at approximately 30 wt% H(2)O. This indicates that collagen is essentially dehydrated in cartilage tissue under very high mechanical load, which provides insights into the elastic properties of cartilage collagen, although the mechanical pressures applied here exceed the physiological limit.
Collapse
Affiliation(s)
- Göran Zernia
- Junior Research Group Solid-State NMR Studies of the Structure of Membrane-Associated Proteins, University of Leipzig, D-04107 Leipzig, Germany
| | | |
Collapse
|
27
|
Schroeder Y, Wilson W, Huyghe JM, Baaijens FPT. Osmoviscoelastic finite element model of the intervertebral disc. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2006; 15 Suppl 3:S361-71. [PMID: 16724211 PMCID: PMC2335381 DOI: 10.1007/s00586-006-0110-3] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2005] [Revised: 03/07/2006] [Accepted: 03/27/2006] [Indexed: 10/24/2022]
Abstract
Intervertebral discs have a primarily mechanical role in transmitting loads through the spine. The disc is subjected to a combination of elastic, viscous and osmotic forces; previous 3D models of the disc have typically neglected osmotic forces. The fibril-reinforced poroviscoelastic swelling model, which our group has recently developed, is used to compute the interplay of osmotic, viscous and elastic forces in an intervertebral disc under axial compressive load. The unloaded 3D finite element mesh equilibrates in a physiological solution, and exhibits an intradiscal pressure of about 0.2 MPa. Before and after axial loading the numerically simulated hydrostatic pressure compares well with the experimental ranges measured. Loading the disc decreased the height of the disc and results in an outward bulging of the outer annulus. Fiber stresses were highest on the most outward bulging on the posterior-lateral side. The osmotic forces resulted in tensile hoop stresses, which were higher than typical values in a non-osmotic disc. The computed axial stress profiles reproduced the main features of the stress profiles, in particular the characteristic posterior and anterior stress which were observed experimentally.
Collapse
Affiliation(s)
- Yvonne Schroeder
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | | | | | | |
Collapse
|
28
|
Wiig H, Tenstad O, Bert JL. Effect of hydration on interstitial distribution of charged albumin in rat dermis in vitro. J Physiol 2005; 569:631-41. [PMID: 16210353 PMCID: PMC1464246 DOI: 10.1113/jphysiol.2005.096792] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
At physiological pH, negatively charged glycosaminoglycans in the extracellular matrix may influence distribution volume of macromolecular probes, a phenomenon of importance for hydration of the interstitium and therefore for body fluid balance. We hypothesized that such charge effect was dependent on hydration. Human serum albumin (HSA) (the pH value for the isoelectric point (pI) = 4.9) was made neutral by cationization (cHSA) (pI = 7.6). Rat dermis was studied in vitro in a specially designed equilibration cell allowing control of hydration. Using a buffer containing labelled native HSA and cHSA, the distribution volumes were calculated relative to that of 51Cr-EDTA, an extracellular tracer. During changes in hydration (H), defined as (wet weight - dry weight) (dry weight)(-1)), the slope of the equation describing the relationship between extracellular fluid volume (V(x)) (in g H2O (g dry weight)(-1)) and H (V(x) = 0.925 H + 0.105) differed significantly from that for available volumes of cHSA (V(a,cHSA) = 0.624 H - 0.538) and HSA (V(a,HSA) = 0.518 H - 0.518). A gradual reduction in H led to a reduction in difference between available volumes for the two albumin species. Screening the fixed charges by 1 m NaCl resulted in similar available and excluded volumes of native HSA and neutral cHSA. We conclude that during gradual dehydration, there is a reduced effect of fixed negative charges on interstitial exclusion of charged macromolecules. This effect may be explained by a reduced hydration domain surrounding tissue and probe macromolecules in conditions of increased electrostatic interactions. Furthermore, screening of negative charges suggested that hyaluronan associated with collagen may influence intrafibrillar volume of collagen and thereby available and excluded volume fraction.
Collapse
Affiliation(s)
- Helge Wiig
- Department of Biomedicine, University of Bergen, Jonas Lies vei 91, N-5009 Bergen, Norway.
| | | | | |
Collapse
|
29
|
Loret B, Simões FMF. Mechanical effects of ionic replacements in articular cartilage. Part II: Simulations of successive substitutions of NaCl and CaCl2. Biomech Model Mechanobiol 2005; 4:81-99. [PMID: 16001248 DOI: 10.1007/s10237-004-0063-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2004] [Accepted: 11/30/2004] [Indexed: 10/25/2022]
Abstract
A three-phase multi-species electro-chemo-mechanical model of articular cartilage was developed in a companion paper, Loret and Simões (in Biomech Model Mechanobiol, in press, DOI 10.1007/s10237-004-0062-7). The model can handle mechanical and chemical loadings and unloadings involving the two salts, NaCl and CaCl(2). In order to reproduce experimental data, the shielding effects are made cation-dependent. In a tensile experiment, at constant axial strain, refreshment of the bath in contact with the cartilage is observed, and simulated, to induce a much different increase in tension depending on the order of the chemical sequence to which the cartilage is exposed. For example, the sequence dw (distilled water)-NaCl-dw-CaCl(2)-dw results in a decrease in tension. But the initial tension is recovered if the chemical sequence is pursued by NaCl-dw. Therefore, ionic replacements are essentially reversible, as evidenced when the chemical loading events respect a certain symmetry. Distinct shielding effects by cations sodium and calcium stem from two main features: (1) different free enthalpies of formation that represent different affinities of the proteoglycans for these ions and that result in an equilibrium constant not equal to 1; (2) distinct valences but approximately the same diameter, which results in a more efficient shielding by cations calcium. The model accounts also: (1) for the anisotropy of the mechanical properties that are due to the strong orientation of collagen fibers; (2) for large deformations that occur during uniaxial traction with deionized water.
Collapse
Affiliation(s)
- Benjamin Loret
- Laboratoire Sols, Solides, Structures, B.P. 53X, 38041, Grenoble Cedex, France.
| | | |
Collapse
|
30
|
Chahine NO, Chen FH, Hung CT, Ateshian GA. Direct measurement of osmotic pressure of glycosaminoglycan solutions by membrane osmometry at room temperature. Biophys J 2005; 89:1543-50. [PMID: 15980166 PMCID: PMC1366659 DOI: 10.1529/biophysj.104.057315] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Articular cartilage is a hydrated soft tissue composed of negatively charged proteoglycans fixed within a collagen matrix. This charge gradient causes the tissue to imbibe water and swell, creating a net osmotic pressure that enhances the tissue's ability to bear load. In this study we designed and utilized an apparatus for directly measuring the osmotic pressure of chondroitin sulfate, the primary glycosaminoglycan found in articular cartilage, in solution with varying bathing ionic strength (0.015 M, 0.15 M, 0.5 M, 1 M, and 2 M NaCl) at room temperature. The osmotic pressure (pi) was found to increase nonlinearly with increasing chondroitin sulfate concentration and decreasing NaCl ionic bath environment. Above 1 M NaCl, pi changes negligibly with further increases in salt concentration, suggesting that Donnan osmotic pressure is negligible above this threshold, and the resulting pressure is attributed to configurational entropy. Results of the current study were also used to estimate the contribution of osmotic pressure to the stiffness of cartilage based on theoretical and experimental considerations. Our findings indicate that the osmotic pressure resulting from configurational entropy is much smaller in cartilage (based on an earlier study on bovine articular cartilage) than in free solution. The rate of change of osmotic pressure with compressive strain is found to contribute approximately one-third of the compressive modulus (H(A)(eff)) of cartilage (Pi approximately H(A)(eff)/3), with the balance contributed by the intrinsic structural modulus of the solid matrix (i.e., H(A) approximately 2H(A)(eff)/3). A strong dependence of this intrinsic modulus on salt concentration was found; therefore, it appears that proteoglycans contribute structurally to the magnitude of H(A), in a manner independent of osmotic pressure.
Collapse
Affiliation(s)
- Nadeen O Chahine
- Musculoskeletal Biomechanics Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York 10027, USA
| | | | | | | |
Collapse
|
31
|
Livney YD, Portnaya I, Faupin B, Ramon O, Cohen Y, Cogan U, Mizrahi S. Interactions between inorganic salts and polyacrylamide in aqueous solutions and gels. ACTA ACUST UNITED AC 2003. [DOI: 10.1002/polb.10406] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
32
|
Hing WA, Sherwin AF, Poole CA. The influence of the pericellular microenvironment on the chondrocyte response to osmotic challenge. Osteoarthritis Cartilage 2002; 10:297-307. [PMID: 11950253 DOI: 10.1053/joca.2002.0517] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To examine whether differences in the pericellular microenvironment of different chondron preparations influence the chondrocyte volume regulatory response to experimental osmotic challenge. DESIGN Mechanically extracted chondrons (MC), enzymatically extracted chondrons (EC) and isolated chondrocytes (IC) were seeded into agarose and sampled at 1, 3 and 7 days. Samples mounted in a perfusion chamber were subjected to osmotic challenge. The cross-sectional areas of the chondrocyte and pericellular microenvironment were measured under isotonic, hypertonic and hypotonic conditions, and percentage change calculated. Separate samples were immunolabeled for type VI collagen and keratan sulfate. RESULTS Initially, the microenvironment of MC represented 60% of the chondron area and was occupied by type VI collagen and keratan sulfate. In EC, the microenvironment comprised 18% of the chondron area with narrow bands of type VI collagen and keratan sulfate. IC had no visible microenvironment, with small amounts of type VI collagen and keratan sulfate present. All preparations sequestered additional pericellular macromolecules during culture. Under isotonic conditions, the EC and IC chondrocytes were larger than those of MC. All chondrocytes shrank under hypertonic conditions and swelled under hypotonic conditions. MC were the least responsive, displaying the most efficient volume regulation. IC showed the largest response initially but this decreased with time. EC exhibited intermediate responses that decreased as the microenvironment increased in size. CONCLUSIONS The composition and structural integrity of the pericellular microenvironment do influence the cellular response to experimental osmotic challenge. This suggests that the microenvironment functions in situ to mediate the chondrocyte response to physicochemical changes associated with joint loading.
Collapse
Affiliation(s)
- W A Hing
- Division of Anatomy with Radiology, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand.
| | | | | |
Collapse
|
33
|
Livney YD, Ramon O, Kesselman E, Cogan U, Mizrahi S, Cohen Y. Swelling of dextran gel and osmotic pressure of soluble dextran in the presence of salts. ACTA ACUST UNITED AC 2001. [DOI: 10.1002/polb.10038] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
34
|
Doughty MJ. Re-assessment of the potential impact of physiologically relevant pH changes on the hydration properties of the isolated mammalian corneal stroma. BIOCHIMICA ET BIOPHYSICA ACTA 1999; 1472:99-106. [PMID: 10572930 DOI: 10.1016/s0304-4165(99)00109-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The pH sensitivity of the swelling of the mammalian corneal stroma was reinvestigated to assess whether or not there were detectable differences in the hydration properties of this collagen-keratocyte matrix within a physiologically relevant range (as opposed to extremes of acid or alkaline pH) and at a physiologically relevant temperature. From recent post-mortem eyes of adult cows, square (8 x 8 mm) samples of corneal stroma were prepared and incubated in an isotonic, buffered (HEPES etc.), mixed salts solution with added glucose at 37 degrees C. The time-dependent changes in wet mass were assessed over 24 h. The rate and magnitude of stromal swelling were different within the range of pH 6.5-8.5. The wet mass of stromal samples increased almost 2-fold within 1 h, and then at lesser rates to realise 3.25-3.75-fold and 4-5-fold increases in wet mass by 9 h and 24 h respectively. The maximum increases were observed at pH 7.25-7.5, with most of the effect being the result of differences in the initial rate of swelling. The discontinuous swelling and the pH effect on the rates of swelling were also evident when the data were fitted to a previous kinetic model (Elliott et al., J. Physiol. (Lond.) 298 (1980) 453-470). It is concluded that pH changes in the physiological range can have a small but reproducible impact on the swelling kinetics of the isolated mammalian corneal stroma ex vivo.
Collapse
Affiliation(s)
- M J Doughty
- Department of Vision Sciences, Glasgow-Caledonian University, Glasgow, UK.
| |
Collapse
|