1
|
Beykou M, Bousgouni V, Moser N, Georgiou P, Bakal C. Biocompatibility characterisation of CMOS-based Lab-on-Chip electrochemical sensors for in vitro cancer cell culture applications. Biosens Bioelectron 2024; 262:116513. [PMID: 38941688 DOI: 10.1016/j.bios.2024.116513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 06/04/2024] [Accepted: 06/17/2024] [Indexed: 06/30/2024]
Abstract
Lab-on-Chip electrochemical sensors, such as Ion-Sensitive Field-Effect Transistors (ISFETs), are being developed for use in point-of-care diagnostics, such as pH detection of tumour microenvironments, due to their integration with standard Complementary Metal Oxide Semiconductor (CMOS) technology. With this approach, the passivation of the CMOS process is used as a sensing layer to minimise post-processing, and Silicon Nitride (Si3N4) is the most common material at the microchip surface. ISFETs have the potential to be used for cell-based assays however, there is a poor understanding of the biocompatibility of microchip surfaces. Here, we quantitatively evaluated cell adhesion, morphogenesis, proliferation and mechano-responsiveness of both normal and cancer cells cultured on a Si3N4, sensor surface. We demonstrate that both normal and cancer cell adhesion decreased on Si3N4. Activation of the mechano-responsive transcription regulators, YAP/TAZ, are significantly decreased in cancer cells on Si3N4 in comparison to standard cell culture plastic, whilst proliferation marker, Ki67, expression markedly increased. Non-tumorigenic cells on chip showed less sensitivity to culture on Si3N4 than cancer cells. Treatment with extracellular matrix components increased cell adhesion in normal and cancer cell cultures, surpassing the adhesiveness of plastic alone. Moreover, poly-l-ornithine and laminin treatment restored YAP/TAZ levels in both non-tumorigenic and cancer cells to levels comparable to those observed on plastic. Thus, engineering the electrochemical sensor surface with treatments will provide a more physiologically relevant environment for future cell-based assay development on chip.
Collapse
Affiliation(s)
- Melina Beykou
- Imperial College London, Department of Electrical and Electronic Engineering, Circuits and Systems Group, South Kensington Campus, London, SW7 2AZ, UK; Institute of Cancer Research, Division of Cancer Biology, Dynamical Cell Systems, London, SW3 6JB, UK; Cancer Research UK Convergence Science Centre, South Kensington Campus, London, SW7 2AZ, UK.
| | - Vicky Bousgouni
- Institute of Cancer Research, Division of Cancer Biology, Dynamical Cell Systems, London, SW3 6JB, UK
| | - Nicolas Moser
- Imperial College London, Department of Electrical and Electronic Engineering, Circuits and Systems Group, South Kensington Campus, London, SW7 2AZ, UK; Cancer Research UK Convergence Science Centre, South Kensington Campus, London, SW7 2AZ, UK
| | - Pantelis Georgiou
- Imperial College London, Department of Electrical and Electronic Engineering, Circuits and Systems Group, South Kensington Campus, London, SW7 2AZ, UK; Cancer Research UK Convergence Science Centre, South Kensington Campus, London, SW7 2AZ, UK.
| | - Chris Bakal
- Institute of Cancer Research, Division of Cancer Biology, Dynamical Cell Systems, London, SW3 6JB, UK; Cancer Research UK Convergence Science Centre, South Kensington Campus, London, SW7 2AZ, UK.
| |
Collapse
|
2
|
Chakraborty P, Krishnani KK. Emerging bioanalytical sensors for rapid and close-to-real-time detection of priority abiotic and biotic stressors in aquaculture and culture-based fisheries. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 838:156128. [PMID: 35605873 DOI: 10.1016/j.scitotenv.2022.156128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 05/12/2022] [Accepted: 05/17/2022] [Indexed: 06/15/2023]
Abstract
Abiotic stresses of various chemical contamination of physical, inorganic, organic and biotoxin origin and biotic stresses of bacterial, viral, parasitic and fungal origins are the significant constraints in achieving higher aquaculture production. Testing and rapid detection of these chemical and microbial contaminants are crucial in identifying and mitigating abiotic and biotic stresses, which has become one of the most challenging aspects in aquaculture and culture-based fisheries. The classical analytical techniques, including titrimetric methods, spectrophotometric, mass spectrometric, spectroscopic, and chromatographic techniques, are tedious and sometimes inaccessible when required. The development of novel and improved bioanalytical methods for rapid, selective and sensitive detection is a wide and dynamic field of research. Biosensors offer precise detection of biotic and abiotic stressors in aquaculture and culture-based fisheries within no time. This review article allows filling the knowledge gap for detection and monitoring of chemical and microbial contaminants of abiotic and biotic origin in aquaculture and culture-based fisheries using nano(bio-) analytical technologies, including nano(bio-)molecular and nano(bio-)sensing techniques.
Collapse
Affiliation(s)
- Puja Chakraborty
- ICAR-Central Institute of Fisheries Education, Panch Marg, Off Yari Road, Versova, Andheri (W), Mumbai 400061, India
| | - K K Krishnani
- ICAR-Central Institute of Fisheries Education, Panch Marg, Off Yari Road, Versova, Andheri (W), Mumbai 400061, India.
| |
Collapse
|
3
|
Saito T, Nishida Y, Tabata M, Isobayashi A, Tomizawa H, Miyahara Y, Sugizaki Y. Molecular Interactions between an Enzyme and Its Inhibitor for Selective Detection of Limonene. Anal Chem 2022; 94:7692-7702. [PMID: 35543317 DOI: 10.1021/acs.analchem.2c01110] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Researchers widely apply enzyme inhibition to chemicals such as pesticides, nerve gases, and anti-Alzheimer's drugs. However, application of enzyme inhibition to odorant sensors is less common because the corresponding reaction mechanisms have not yet been clarified in detail. In this study, we propose a new strategy for highly selective detection of odorant molecules by using an inhibitor-specific enzyme. As an example, we analyzed the selective interactions between acetylcholinesterase (AChE) and limonene─the major odorant of citrus and an AChE inhibitor─using molecular dynamics simulations. In these simulations, limonene was found to be captured at specific binding sites of AChE by modifying the binding site of acetylcholine (ACh), which induced inhibition of the catalytic activity of AChE toward ACh hydrolysis. We confirmed the simulation results by experiments using an ion-sensitive field-effect transistor, and the degree of inhibition of ACh hydrolysis depended on the limonene concentration. Accordingly, we quantitatively detected limonene at a detection limit of 5.7 μM. We furthermore distinguished the response signals to limonene from those to other odorants, such as pinene and perillic acid. Researchers will use our proposed odorant detection method for other odorant-enzyme combinations and applications of miniaturized odorant-sensing systems based on rapid testing.
Collapse
Affiliation(s)
- Tatsuro Saito
- Toshiba Corporation, 1 Komukai-Toshiba-cho, Saiwai, Kawasaki 212-8582, Japan
| | - Yasutaka Nishida
- Toshiba Corporation, 1 Komukai-Toshiba-cho, Saiwai, Kawasaki 212-8582, Japan
| | - Miyuki Tabata
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
| | - Atsunobu Isobayashi
- Toshiba Corporation, 1 Komukai-Toshiba-cho, Saiwai, Kawasaki 212-8582, Japan
| | - Hideyuki Tomizawa
- Toshiba Corporation, 1 Komukai-Toshiba-cho, Saiwai, Kawasaki 212-8582, Japan
| | - Yuji Miyahara
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
| | - Yoshiaki Sugizaki
- Toshiba Corporation, 1 Komukai-Toshiba-cho, Saiwai, Kawasaki 212-8582, Japan
| |
Collapse
|
4
|
Bhatt D, Panda S. Dual‐gate ion‐sensitive field‐effect transistors: A review. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Affiliation(s)
- Deepa Bhatt
- National Centre for Flexible Electronics Indian Institute of Technology Kanpur Kanpur India
- Samtel Centre for Display Technologies Indian Institute of Technology Kanpur Kanpur India
| | - Siddhartha Panda
- National Centre for Flexible Electronics Indian Institute of Technology Kanpur Kanpur India
- Samtel Centre for Display Technologies Indian Institute of Technology Kanpur Kanpur India
- Department of Chemical Engineering Indian Institute of Technology Kanpur Kanpur India
- Materials Science Programme Indian Institute of Technology Kanpur Kanpur India
| |
Collapse
|
5
|
Chang Y, Wang L, Li R, Zhang Z, Wang Q, Yang J, Guo CF, Pan T. First Decade of Interfacial Iontronic Sensing: From Droplet Sensors to Artificial Skins. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2003464. [PMID: 33346388 DOI: 10.1002/adma.202003464] [Citation(s) in RCA: 80] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 07/16/2020] [Indexed: 05/21/2023]
Abstract
Over the past decade, a brand-new pressure- and tactile-sensing modality, known as iontronic sensing has emerged, utilizing the supercapacitive nature of the electrical double layer (EDL) that occurs at the electrolytic-electronic interface, leading to ultrahigh device sensitivity, high noise immunity, high resolution, high spatial definition, optical transparency, and responses to both static and dynamic stimuli, in addition to thin and flexible device architectures. Together, it offers unique combination of enabling features to tackle the grand challenges in pressure- and tactile-sensing applications, in particular, with recent interest and rapid progress in the development of robotic intelligence, electronic skin, wearable health as well as the internet-of-things, from both academic and industrial communities. A historical perspective of the iontronic sensing discovery, an overview of the fundamental working mechanism along with its device architectures, a survey of the unique material aspects and structural designs dedicated, and finally, a discussion of the newly enabled applications, technical challenges, and future outlooks are provided for this promising sensing modality with implementations. The state-of-the-art developments of the iontronic sensing technology in its first decade are summarized, potentially providing a technical roadmap for the next wave of innovations and breakthroughs in this field.
Collapse
Affiliation(s)
- Yu Chang
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Science, Shenzhen, 518055, China
| | - Liu Wang
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Ruya Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Zhichao Zhang
- Micro and Nano-Innovations (MiNI) Laboratory, Department of Biomedical Engineering, University of California, Davis, CA, 95616, USA
| | - Qi Wang
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Junlong Yang
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Chuan Fei Guo
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Tingrui Pan
- Micro and Nano-Innovations (MiNI) Laboratory, Department of Biomedical Engineering, University of California, Davis, CA, 95616, USA
| |
Collapse
|
6
|
Development of an ImmunoFET for Analysis of Tumour Necrosis Factor-α in Artificial Saliva: Application for Heart Failure Monitoring. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9020026] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Assessing tumour necrosis factor-α (TNF-α) levels in the human body has become an essential tool to recognize heart failure (HF). In this work, label-free, rapid, easy to use ImmunoFET based on an ion-sensitive field effect transistor (ISFET) was developed for the detection of TNF-α protein. Monoclonal anti-TNF-α antibodies (anti-TNF-α mAb) were immobilized on an ISFET gate made of silicon nitride (Si3N4) after salinization with 11-(triethoxysilyl) undecanal (TESUD). The obtained ISFET functionalized with the mAbs (ImmunoFET) was used to detect TNF-α protein in both phosphate buffer saline (PBS) and artificial saliva (AS). The change in the threshold voltage of the gate (∆VT) showed approximately linear dependency on the concentration of the antigens in the range 5–20 pg/mL for both matrixes. The cross-selectivity study showed that the developed ImmunoFET demonstrated to be selective towards TNF-α, when compared to other HF biomarkers such as N-terminal pro-brain natriuretic peptide (NT-proBNP), interleukin-10 (IL-10), and cortisol, even if further experiments have to be carried out for decreasing possible unspecific absorption phenomena. To the best of our knowledge, this is the first ImmunoFET that has been developed based on Si3N4 for TNF-α detection in AS by electrical measurement.
Collapse
|
7
|
Varghese A, Chinnamuthan P, Bhargava L. Fabrication and pH-Sensitivity Analysis of MOS-HEMT Dimensional Variants for Bio-Sensing Applications. IEEE Trans Nanobioscience 2020; 20:28-34. [PMID: 32924942 DOI: 10.1109/tnb.2020.3023725] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This work reports the fabrication, characterization and testing for pH sensitivity of dielectric modulated MOS-HEMT(Metal oxide semiconductor- high electron mobility transistor) devices for bio-sensing applications. The primary aim here is to develop high sensing devices for bio-detections. The oxide based gate area is used in ensuring the device performance through pH detection done prior to packaging and metal probing. Device parameters; gate length LG, gate width WG, gate spacing from source-drain ends, LSG and LGD have been varied to investigate the effect on pH sensitivity. The HEMT stack with AlN spacer has been grown through MOCVD (Metal-Organic Chemical Vapor Deposition) technique with no intentional doping on Si (silicon) substrate. Commercial buffer samples for pH values of 4, 7, 9.2 have been used to test the devices using drop casting technique. Drain current (ID) based sensitivity analysis shows that the device having ( [Formula: see text], [Formula: see text] and [Formula: see text]) exhibits a maximum sensitivity of 3.361 mA/pH. The devices exhibit exemplary performance when device dimensions meet the following constraints i.e. LSG: minimum, LG: moderate and LGD > 2*LSG. Average sensitivities attained is in the range 1.69 mA/pH for a device with [Formula: see text], [Formula: see text] and [Formula: see text].
Collapse
|
8
|
Dynamic pH Sensor with Embedded Calibration Scheme by Advanced CMOS FinFET Technology. SENSORS 2019; 19:s19071585. [PMID: 30986913 PMCID: PMC6480048 DOI: 10.3390/s19071585] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 03/26/2019] [Accepted: 03/29/2019] [Indexed: 01/23/2023]
Abstract
In this work, we present a novel pH sensor using efficient laterally coupled structure enabled by Complementary Metal-Oxide Semiconductor (CMOS) Fin Field-Effect Transistor (FinFET) processes. This new sensor features adjustable sensitivity, wide sensing range, multi-pad sensing capability and compatibility to advanced CMOS technologies. With a self-balanced readout scheme and proposed corresponding circuit, the proposed sensor is found to be easily embedded into integrated circuits (ICs) and expanded into sensors array. To ensure the robustness of this new device, the transient response and noise analysis are performed. In addition, an embedded calibration operation scheme is implemented to prevent the proposed sensing device from the background offset from process variation, providing reliable and stable sensing results.
Collapse
|
9
|
Ghoneim MT, Nguyen A, Dereje N, Huang J, Moore GC, Murzynowski PJ, Dagdeviren C. Recent Progress in Electrochemical pH-Sensing Materials and Configurations for Biomedical Applications. Chem Rev 2019; 119:5248-5297. [PMID: 30901212 DOI: 10.1021/acs.chemrev.8b00655] [Citation(s) in RCA: 102] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
pH-sensing materials and configurations are rapidly evolving toward exciting new applications, especially those in biomedical applications. In this review, we highlight rapid progress in electrochemical pH sensors over the past decade (2008-2018) with an emphasis on key considerations, such as materials selection, system configurations, and testing protocols. In addition to recent progress in optical pH sensors, our main focus in this review is on electromechanical pH sensors due to their significant advances, especially in biomedical applications. We summarize developments of electrochemical pH sensors that by virtue of their optimized material chemistries (from metal oxides to polymers) and geometrical features (from thin films to quantum dots) enable their adoption in biomedical applications. We further present an overview of necessary sensing standards and protocols. Standards ensure the establishment of consistent protocols, facilitating collective understanding of results and building on the current state. Furthermore, they enable objective benchmarking of various pH-sensing reports, materials, and systems, which is critical for the overall progression and development of the field. Additionally, we list critical issues in recent literary reporting and suggest various methods for objective benchmarking. pH regulation in the human body and state-of-the-art pH sensors (from ex vivo to in vivo) are compared for suitability in biomedical applications. We conclude our review by (i) identifying challenges that need to be overcome in electrochemical pH sensing and (ii) providing an outlook on future research along with insights, in which the integration of various pH sensors with advanced electronics can provide a new platform for the development of novel technologies for disease diagnostics and prevention.
Collapse
|
10
|
Antony N, Unnikrishnan L, Mohanty S, Nayak SK. The imperative role of polymers in enzymatic cholesterol biosensors- an overview. POLYM-PLAST TECH MAT 2019. [DOI: 10.1080/25740881.2019.1576197] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Neethu Antony
- Laboratory for Advanced Research in Polymeric Materials, Central Institute of Plastics Engineering and Technology, Bhubaneswar, Odisha, India
| | - Lakshmi Unnikrishnan
- Laboratory for Advanced Research in Polymeric Materials, Central Institute of Plastics Engineering and Technology, Bhubaneswar, Odisha, India
| | - Smita Mohanty
- Laboratory for Advanced Research in Polymeric Materials, Central Institute of Plastics Engineering and Technology, Bhubaneswar, Odisha, India
| | - Sanjay K. Nayak
- Laboratory for Advanced Research in Polymeric Materials, Central Institute of Plastics Engineering and Technology, Bhubaneswar, Odisha, India
| |
Collapse
|
11
|
Kwon OS, Song HS, Park TH, Jang J. Conducting Nanomaterial Sensor Using Natural Receptors. Chem Rev 2018; 119:36-93. [DOI: 10.1021/acs.chemrev.8b00159] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Oh Seok Kwon
- Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, Daejeon 34141, Republic of Korea
- Nanobiotechnology and Bioinformatics (Major), University of Science & Technology (UST), Daejon 34141, Republic of Korea
| | - Hyun Seok Song
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
- Division of Bioconvergence Analysis, Korea Basic Science Institute (KBSI), Cheongju 28119, Republic of Korea
- Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
| | - Tai Hyun Park
- School of Chemical and Biological Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Jyongsik Jang
- School of Chemical and Biological Engineering, Seoul National University, Seoul 08826, Republic of Korea
| |
Collapse
|
12
|
Abstract
Hormones produced by glands in the endocrine system and neurotransmitters produced by the nervous system control many bodily functions. The concentrations of these molecules in the body are an indication of its state, hence the use of the term biomarker. Excess concentrations of biomarkers, such as cortisol, serotonin, epinephrine, and dopamine, are released by the body in response to a variety of conditions, for example, emotional state (euphoria, stress) and disease. The development of simple, low-cost modalities for point-of-use (PoU) measurements of biomarkers levels in various bodily fluids (blood, urine, sweat, saliva) as opposed to conventional hospital or lab settings is receiving increasing attention. This paper starts with a review of the basic properties of 12 primary stress-induced biomarkers: origin in the body (i.e., if they are produced as hormones, neurotransmitters, or both), chemical composition, molecular weight (small/medium size molecules and polymers, ranging from ∼100 Da to ∼100 kDa), and hydro- or lipophilic nature. Next is presented a detailed review of the published literature regarding the concentration of these biomarkers found in several bodily fluids that can serve as the medium for determination of the condition of the subject: blood, urine, saliva, sweat, and, to a lesser degree, interstitial tissue fluid. The concentration of various biomarkers in most fluids covers a range of 5-6 orders of magnitude, from hundreds of nanograms per milliliter (∼1 μM) down to a few picograms per milliliter (sub-1 pM). Mechanisms and materials for point-of-use biomarker sensors are summarized, and key properties are reviewed. Next, selected methods for detecting these biomarkers are reviewed, including antibody- and aptamer-based colorimetric assays and electrochemical and optical detection. Illustrative examples from the literature are discussed for each key sensor approach. Finally, the review outlines key challenges of the field and provides a look ahead to future prospects.
Collapse
Affiliation(s)
- Andrew J. Steckl
- Nanoelectronics Laboratory, University of Cincinnati, Cincinnati, Ohio 45221-0030, United States
| | - Prajokta Ray
- Nanoelectronics Laboratory, University of Cincinnati, Cincinnati, Ohio 45221-0030, United States
| |
Collapse
|
13
|
Study of structural properties and sensing performance of high performance sol-gel synthesized CeTixOy sensing membranes. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.03.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
14
|
Hong S, Lee C. The Current Status and Future Outlook of Quantum Dot-Based Biosensors for Plant Virus Detection. THE PLANT PATHOLOGY JOURNAL 2018; 34:85-92. [PMID: 29628814 PMCID: PMC5880352 DOI: 10.5423/ppj.rw.08.2017.0184] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Revised: 01/14/2018] [Accepted: 01/18/2018] [Indexed: 05/23/2023]
Abstract
Enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR), widely used for the detection of plant viruses, are not easily performed, resulting in a demand for an innovative and more efficient diagnostic method. This paper summarizes the characteristics and research trends of biosensors focusing on the physicochemical properties of both interface elements and bioconjugates. In particular, the topological and photophysical properties of quantum dots (QDs) are discussed, along with QD-based biosensors and their practical applications. The QD-based Fluorescence Resonance Energy Transfer (FRET) genosensor, most widely used in the biomolecule detection fields, and QD-based nanosensor for Rev-RRE interaction assay are presented as examples. In recent years, QD-based biosensors have emerged as a new class of sensor and are expected to open opportunities in plant virus detection, but as yet there have been very few practical applications (Table 3). In this article, the details of those cases and their significance for the future of plant virus detection will be discussed.
Collapse
Affiliation(s)
| | - Cheolho Lee
- Corresponding author. Phone) +82-2-940-7188, E-mail)
| |
Collapse
|
15
|
Rajeev G, Prieto Simon B, Marsal LF, Voelcker NH. Advances in Nanoporous Anodic Alumina-Based Biosensors to Detect Biomarkers of Clinical Significance: A Review. Adv Healthc Mater 2018; 7. [PMID: 29205934 DOI: 10.1002/adhm.201700904] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2017] [Revised: 10/06/2017] [Indexed: 02/06/2023]
Abstract
There is a strong and growing demand for compact, portable, rapid, and low-cost devices to detect biomarkers of interest in clinical and point-of-care diagnostics. Such devices aid in early diagnosis of diseases without the need to rely on expensive and time-consuming large instruments in dedicated laboratories. Over the last decade, numerous biosensors have been developed for detection of a wide range of clinical biomarkers including proteins, nucleic acids, growth factors, and bacterial enzymes. Various transduction techniques have been reported based on biosensor technology that deliver substantial advances in analytical performance, including sensitivity, reproducibility, selectivity, and speed for monitoring a wide range of human health conditions. Nanoporous anodic alumina (NAA) has been used extensively for biosensing applications due to its inherent optical and electrochemical properties, ease of fabrication, large surface area, tunable properties, and high stability in aqueous environment. This review focuses on NAA-based biosensing systems for detection of clinically significant biomarkers using various detection techniques with the main focus being on electrochemical and optical transduction methods. The review covers an overview of the importance of biosensors for biomarkers detection, general (surface and structural) properties and fabrication of NAA, and NAA-based biomarker sensing systems.
Collapse
Affiliation(s)
| | - Beatriz Prieto Simon
- Future Industries Institute; Mawson Lakes SA 5095 Australia
- Monash Institute of Pharmaceutical Sciences; Monash University; Parkville VIC 3052 Australia
| | - Lluis F. Marsal
- Departamento de Ingeniería Electrónica; Eléctrica y Automática; Universitat Rovira i Virgili; Avda. Països Catalans 26 43007 Tarragona Spain
| | - Nicolas H. Voelcker
- Future Industries Institute; Mawson Lakes SA 5095 Australia
- Monash Institute of Pharmaceutical Sciences; Monash University; Parkville VIC 3052 Australia
| |
Collapse
|
16
|
Busse C, Biechele P, de Vries I, Reardon KF, Solle D, Scheper T. Sensors for disposable bioreactors. Eng Life Sci 2017; 17:940-952. [PMID: 32624843 DOI: 10.1002/elsc.201700049] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 05/24/2017] [Accepted: 07/14/2017] [Indexed: 12/23/2022] Open
Abstract
Modern bioprocess monitoring demands sensors that provide on-line information about the process state. In particular, sensors for monitoring bioprocesses carried out in single-use bioreactors are needed because disposable systems are becoming increasingly important for biotechnological applications. Requirements for the sensors used in these single-use bioreactors are different than those used in classical reusable bioreactors. For example, long lifetime or resistance to steam and cleaning procedures are less crucial factors, while a requirement of sensors for disposable bioreactors is a cost that is reasonable on a per-use basis. Here, we present an overview of current and emerging sensors for single-use bioreactors, organized by the type of interface of the sensor systems to the bioreactor. A major focus is on non-invasive, in-situ sensors that are based on electromagnetic, semiconducting, optical, or ultrasonic measurements. In addition, new technologies like radio-frequency identification sensors or free-floating sensor spheres are presented. Notably, at this time there is no standard interface between single-use bioreactors and the sensors discussed here. In the future, manufacturers should address this shortcoming to promote single-use bioprocess monitoring and control.
Collapse
Affiliation(s)
- Christoph Busse
- Institute of Technical Chemistry Leibniz University Hannover Germany
| | - Philipp Biechele
- Institute of Technical Chemistry Leibniz University Hannover Germany
| | - Ingo de Vries
- Institute of Technical Chemistry Leibniz University Hannover Germany
| | - Kenneth F Reardon
- Department of Chemical and Biological Engineering Colorado State University USA
| | - Dörte Solle
- Institute of Technical Chemistry Leibniz University Hannover Germany
| | - Thomas Scheper
- Institute of Technical Chemistry Leibniz University Hannover Germany
| |
Collapse
|
17
|
Development of an immunoFET biosensor for the detection of biotinylated PCR product. Heliyon 2016; 2:e00188. [PMID: 27822563 PMCID: PMC5090196 DOI: 10.1016/j.heliyon.2016.e00188] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 09/01/2016] [Accepted: 10/21/2016] [Indexed: 12/19/2022] Open
Abstract
ImmunoFET (IMFET) biosensor is a simple platform for the detection of biotinylated products of polymerase chain reaction (PCR). Construction of the IMFET biosensor started with adsorption of 1.5 mg/mL of protein A (PA) onto the insulated gate surface of ISFET for 90 min. Next, the immobilized 1/500 dilution of anti-biotin antibody was adsorbed onto the PA layer for 60 min. The IMFET biosensor was subsequently ready for detection of the biotinylated amplicon. The IMFET biosensor showed highly specific binding to the biotinylated PCR product of the phaE gene of Haloquadratum walsbyi DSM 16854. The phaE gene is a biomarker of polyhydroxyalkanoate (PHA) producers that contain PHA synthase class III. The lowest amount of DNA template of H. walsbyi DSM 16854 that the IMFET biosensor could detect was 125 fg. The IMFET biosensor has a lower amount of detection compared with a DNA lateral flow biosensor from our previous study. The degree of linearity of the biosensor signal was influenced by the concentration of the biotinylated amplicon. The IMFET biosensor also has a short response time (approximately 30 times) to detect the phaE amplicon compared to an agarose gel electrophoresis. The IMFET biosensor is a promising tool for the detection of the biotinylated PCR product, and it can be integrated into a micro total analysis system (μTAS).
Collapse
|
18
|
Seo J, Song M, Jeong J, Nam S, Heo I, Park SY, Kang IK, Lee JH, Kim H, Kim Y. Broadband pH-Sensing Organic Transistors with Polymeric Sensing Layers Featuring Liquid Crystal Microdomains Encapsulated by Di-Block Copolymer Chains. ACS APPLIED MATERIALS & INTERFACES 2016; 8:23862-23867. [PMID: 27557404 DOI: 10.1021/acsami.6b08257] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We report broadband pH-sensing organic field-effect transistors (OFETs) with the polymer-dispersed liquid crystal (PDLC) sensing layers. The PDLC layers are prepared by spin-coating using ethanol solutions containing 4-cyano-4'-pentyl-biphenyl (5CB) and a diblock copolymer (PAA-b-PCBOA) that consists of LC-philic block [poly(4-cyano-biphenyl-4-oxyundecyl acrylate) (PCBOA)] and acrylic acid block [poly(acrylic acid) (PAA)]. The spin-coated sensing layers feature of 5CB microdomains (<5 μm) encapsulated by the PAA-b-PCBOA polymer chains. The resulting LC-integrated-OFETs (PDLC-i-OFETs) can detect precisely and reproducibly a wide range of pH with only small amounts (10-40 μL) of analyte solutions in both static and dynamic perfusion modes. The positive drain current change is measured for acidic solutions (pH < 7), whereas basic solutions (pH > 7) result in the negative change of drain current. The drain current trend in the present PDLC-i-OFET devices is explained by the shrinking-expanding mechanism of the PAA chains in the diblock copolymer layers.
Collapse
Affiliation(s)
- Jooyeok Seo
- Organic Nanoelectronics Laboratory, Department of Chemical Engineering, School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Myeonghun Song
- Organic Nanoelectronics Laboratory, Department of Chemical Engineering, School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Jaehoon Jeong
- Organic Nanoelectronics Laboratory, Department of Chemical Engineering, School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Sungho Nam
- Organic Nanoelectronics Laboratory, Department of Chemical Engineering, School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
- Department of Physics, Division of Mathematical, Physical and Life Sciences, University of Oxford , Oxford OX1 3PD, United Kingdom
| | - Inseok Heo
- Department of Polymer Science and Engineering and Graduate School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Soo-Young Park
- Department of Polymer Science and Engineering and Graduate School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Inn-Kyu Kang
- Department of Polymer Science and Engineering and Graduate School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Joon-Hyung Lee
- School of Materials Science and Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Hwajeong Kim
- Organic Nanoelectronics Laboratory, Department of Chemical Engineering, School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
- Priority Research Center, Research Institute of Advanced Energy Technology, Kyungpook National University , Daegu 41566, Republic of Korea
| | - Youngkyoo Kim
- Organic Nanoelectronics Laboratory, Department of Chemical Engineering, School of Applied Chemical Engineering, Kyungpook National University , Daegu 41566, Republic of Korea
| |
Collapse
|
19
|
Imaizumi Y, Goda T, Toya Y, Matsumoto A, Miyahara Y. Oleyl group-functionalized insulating gate transistors for measuring extracellular pH of floating cells. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS 2016; 17:337-345. [PMID: 27877886 PMCID: PMC5101916 DOI: 10.1080/14686996.2016.1198217] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Revised: 05/20/2016] [Accepted: 06/02/2016] [Indexed: 05/23/2023]
Abstract
The extracellular ionic microenvironment has a close relationship to biological activities such as by cellular respiration, cancer development, and immune response. A system composed of ion-sensitive field-effect transistors (ISFET), cells, and program-controlled fluidics has enabled the acquisition of real-time information about the integrity of the cell membrane via pH measurement. Here we aimed to extend this system toward floating cells such as T lymphocytes for investigating complement activation and pharmacokinetics through alternations in the plasma membrane integrity. We functionalized the surface of tantalum oxide gate insulator of ISFET with oleyl-tethered phosphonic acid for interacting with the plasma membranes of floating cells without affecting the cell signaling. The surface modification was characterized by X-ray photoelectron spectroscopy and water contact angle measurements. The Nernst response of -37.8 mV/pH was obtained for the surface-modified ISFET at 37 °C. The oleyl group-functionalized gate insulator successfully captured Jurkat T cells in a fluidic condition without acute cytotoxicity. The system was able to record the time course of pH changes at the cells/ISFET interface during the process of instant addition and withdrawal of ammonium chloride. Further, the plasma membrane injury of floating cells after exposure by detergent Triton™ X-100 was successfully determined using the modified ISFET with enhanced sensitivity as compared with conventional hemolysis assays.
Collapse
Affiliation(s)
- Yuki Imaizumi
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - Tatsuro Goda
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - Yutaro Toya
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - Akira Matsumoto
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - Yuji Miyahara
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| |
Collapse
|
20
|
Nehra A, Pal Singh K. Current trends in nanomaterial embedded field effect transistor-based biosensor. Biosens Bioelectron 2015. [DOI: 10.1016/j.bios.2015.07.030] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
21
|
Pan TM, Lin TW, Chen CY. Label-free detection of rheumatoid factor using YbYxOy electrolyte–insulator–semiconductor devices. Anal Chim Acta 2015; 891:304-11. [DOI: 10.1016/j.aca.2015.08.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 08/11/2015] [Accepted: 08/13/2015] [Indexed: 11/26/2022]
|
22
|
Recent Developments in R.F. Magnetron Sputtered Thin Films for pH Sensing Applications—An Overview. COATINGS 2014. [DOI: 10.3390/coatings4040756] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
23
|
Barik MA, Sarma MK, Sarkar CR, Dutta JC. Highly Sensitive Potassium-Doped Polypyrrole/Carbon Nanotube-Based Enzyme Field Effect Transistor (ENFET) for Cholesterol Detection. Appl Biochem Biotechnol 2014; 174:1104-14. [DOI: 10.1007/s12010-014-1029-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Accepted: 06/19/2014] [Indexed: 10/25/2022]
|
24
|
Tulip FS, Eteshola E, Desai S, Mostafa S, Roopa S, Evans B, Islam SK. Direct label-free electrical immunodetection of transplant rejection protein biomarker in physiological buffer using floating gate AlGaN/GaN high electron mobility transistors. IEEE Trans Nanobioscience 2014; 13:138-45. [PMID: 24803243 DOI: 10.1109/tnb.2014.2318234] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Monokine induced by interferon gamma (MIG/CXCL9) is used as an immune biomarker for early monitoring of transplant or allograft rejection. This paper demonstrates a direct electrical, label-free detection method of recombinant human MIG with anti-MIG IgG molecules in physiologically relevant buffer environment. The sensor platform used is a biologically modified GaN-based high electron mobility transistor (HEMT) device. Biomolecular recognition capability was provided by using high affinity anti-MIG monoclonal antibody to form molecular affinity interface receptors on short N-hydroxysuccinimide-ester functionalized disulphide (DSP) self-assembled monolayers (SAMs) on the gold sensing gate of the HEMT device. A floating gate configuration has been adopted to eliminate the influences of external gate voltage. Preliminary test results with the proposed chemically treated GaN HEMT biosensor show that MIG can be detected for a wide range of concentration varying from 5 ng/mL to 500 ng/mL.
Collapse
|
25
|
Kim DM, Jeong YH. Nanowire BioFETs: An Overview. NANOWIRE FIELD EFFECT TRANSISTORS: PRINCIPLES AND APPLICATIONS 2014. [PMCID: PMC7121775 DOI: 10.1007/978-1-4614-8124-9_9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
In this chapter, the biosensing as a key element of nanotechnology and commanding a wide range of applications is discussed, e.g., fast and efficient clinical diagnostics, health care, security, environmental monitoring, etc. The operation and sensing mechanism of BioFETs and ion-sensitive FETs are elaborated on a molecular level, based upon the molecular recognition between target and probe molecules and the input gate voltage and output ON current of the conventional FETs. In particular, the extended roles of the gate electrode of BioFETs as the probing surface are highlighted, in comparison with the conventional gate electrode, together with the physical and biological processes for detecting target molecules. Moreover, the bottom-up syntheses of vertical and horizontal nanowires are presented and the ensuing nanowires are characterized. Also, the top-down and bottom-up approaches for processing nanowires are compared by taking as criteria the process complexity and quality of the nanowires produced. Finally, the future prospects of bio-sensing are presented.
Collapse
Affiliation(s)
- Dae Mann Kim
- Korea Institute for Advanced Study, Seoul, Korea, Republic of (South Korea)
| | - Yoon-Ha Jeong
- Dept. of Creative IT Excellence Eng., POSTECH, Gyeongbuk, Korea, Republic of (South Korea)
| |
Collapse
|
26
|
Abstract
Fresh water deficiency caused by climate change calls for employing novel measures to ensure safety of drinking water supply. Wireless sensor networks can be used for monitoring hydrological conditions across wide area, allowing flow forecasting and early detection of pollutants. While there are no fundamental technological obstacles to implementation of large area sensor networks, their feasibility is constrained by unit cost of sensing nodes. This paper describes a low-cost pH sensor, intended for use in fresh water monitoring. The sensor was fabricated in a standard thick film process, and an off-the-shelf resistive paste was used as a sensing material. For the fabrication of sensor, RuO2 resistive paste was screen printed on the alumina substrate with silver conducting layer. Test solutions with pH ranging from 2 to 10 were prepared from HCl or KOH solutions. The potential difference between reference and sensing electrode (electromotive force emf of an electrochemical cell) should be proportional to the pH of a solution according to the Nernst equation. The fabricated sensor exhibits Nernstian response to pH. Influence of storage conditions on sensing performance was also investigated.
Collapse
|
27
|
Ferris RJ, Lin S, Therezien M, Yellen BB, Zauscher S. Electric double layer formed by polarized ferroelectric thin films. ACS APPLIED MATERIALS & INTERFACES 2013; 5:2610-2617. [PMID: 23484485 DOI: 10.1021/am3031954] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Ferroelectric surfaces can have very high surface charge densities that can be harnessed for manipulation of charged colloidal particles and soft matter in aqueous environments. Here, we report on the electrical double layer (EDL) formed by polarized ultrasmooth lead zirconium titanate (US-PZT) thin films in dilute electrolyte solutions. Using colloidal probe force microscopy (CPFM) measurements, we show that the ion distribution within the double layer can be changed by reversing the ferroelectric polarization state of US-PZT. The interaction force in dilute 1:1 electrolyte solution between the negatively charged probe and a positive surface charge (upward polarized) US-PZT thin film is attractive, while the interaction force is repulsive for a negative surface charge (downward polarized) film. We modeled these interactions with a constant-potential EDL model between dissimilar surfaces with the inclusion of a Stern layer. We report the surface potentials at the inner and outer-Helmholtz planes both for polarization states and for a range of ionic strength solutions. Effects of free-charge carriers, limitations of the analytical model, and effects of surface roughness are discussed.
Collapse
Affiliation(s)
- Robert J Ferris
- Department of Mechanical Engineering and Material Science, Duke University, 144 Hudson Hall, Durham, North Carolina 27708, United States
| | | | | | | | | |
Collapse
|
28
|
Wu MH, Yang HW, Hua MY, Peng YB, Pan TM. High-κ GdTixOy sensing membrane-based electrolyte-insulator-semiconductor with magnetic nanoparticles as enzyme carriers for protein contamination-free glucose biosensing. Biosens Bioelectron 2013; 47:99-105. [PMID: 23567628 DOI: 10.1016/j.bios.2013.03.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2012] [Revised: 02/19/2013] [Accepted: 03/08/2013] [Indexed: 12/01/2022]
Abstract
This paper reports an electrolyte-insulator-semiconductor (EIS) device featuring a novel high-κ GdTixOy sensing membrane for high-performance pH sensing and glucose biosensing. The effect of the annealing temperature (700, 800, or 900°C) on the sensing properties of the GdTixOy membranes was investigated. The GdTixOy EIS device annealed at 900°C exhibited the greatest pH sensing performance, including the highest sensitivity (62.12mV/pH), the smallest hysteresis voltage (5mV), and the lowest drift rate (0.4mV/h), presumably because of its well-crystallized GdTixOy structure. To overcome the problems typically encountered during the practical application of biosensors (e.g., protein adsorption; preservation of enzymatic activity), we employed Fe3O4-based magnetic nanoparticles (MNPs) as enzyme carriers. The adsorption of serum protein on the unmodified sensing membrane led to poor EIS-based pH sensing (r(2)=0.71); the performance was greatly improved, however, after attaching the MNPs to the sensing membrane, thereby blocking protein adsorption significantly (by 98%) and allowing excellent pH sensing (r(2)=0.99). Moreover, we prepared a hybrid configuration of the proposed GdTixOy membrane-EIS, with magnetically attached glucose oxidase-immobilized MNPs, for glucose biosensing. The use of MNPs as enzyme carriers effectively preserved the enzymatic activity of glucose oxidase, with 45.3% of the original enzymatic activity retained after 120h of storage at 4°C (compared with complete loss of the free enzyme's activity under the same storage conditions). In addition, the proposed biosensor exhibited superior detection sensitivity of 11.03mV/mM relative to that (8.17mV/mM) obtained using the conventional enzyme immobilization method. Finally, we established the accuracy of the proposed method for blood glucose measurement; gratifyingly, blood glucose detection was comparable with the high-sensitivity glucose quantification obtained using a commercial glucose assay kit.
Collapse
Affiliation(s)
- Min-Hsien Wu
- Graduate Institute of Biochemical and Biomedical Engineering, Chang Gung University, Kwei-Shan, Tao-Yuan 33302, Taiwan
| | | | | | | | | |
Collapse
|
29
|
Development of an integrated electrochemical system for in vitro yeast viability testing. Biosens Bioelectron 2013; 40:315-22. [DOI: 10.1016/j.bios.2012.07.070] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 06/29/2012] [Accepted: 07/15/2012] [Indexed: 11/22/2022]
|
30
|
Structural and sensing characteristics of Gd2Ti2O7, Er2TiO5 and Lu2Ti2O7 sensing membrane electrolyte–insulator–semiconductor for bio-sensing applications. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2012.10.099] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
31
|
Dorvel BR, Reddy B, Go J, Guevara CD, Salm E, Alam MA, Bashir R. Silicon nanowires with high-k hafnium oxide dielectrics for sensitive detection of small nucleic acid oligomers. ACS NANO 2012; 6:6150-64. [PMID: 22695179 PMCID: PMC3412126 DOI: 10.1021/nn301495k] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Nanobiosensors based on silicon nanowire field effect transistors offer advantages of low cost, label-free detection, and potential for massive parallelization. As a result, these sensors have often been suggested as an attractive option for applications in point-of-care (POC) medical diagnostics. Unfortunately, a number of performance issues, such as gate leakage and current instability due to fluid contact, have prevented widespread adoption of the technology for routine use. High-k dielectrics, such as hafnium oxide (HfO(2)), have the known ability to address these challenges by passivating the exposed surfaces against destabilizing concerns of ion transport. With these fundamental stability issues addressed, a promising target for POC diagnostics and SiNWFETs has been small oligonucleotides, more specifically, microRNA (miRNA). MicroRNAs are small RNA oligonucleotides which bind to mRNAs, causing translational repression of proteins, gene silencing, and expressions are typically altered in several forms of cancer. In this paper, we describe a process for fabricating stable HfO(2) dielectric-based silicon nanowires for biosensing applications. Here we demonstrate sensing of single-stranded DNA analogues to their microRNA cousins using miR-10b and miR-21 as templates, both known to be upregulated in breast cancer. We characterize the effect of surface functionalization on device performance using the miR-10b DNA analogue as the target sequence and different molecular weight poly-l-lysine as the functionalization layer. By optimizing the surface functionalization and fabrication protocol, we were able to achieve <100 fM detection levels of the miR-10b DNA analogue, with a theoretical limit of detection of 1 fM. Moreover, the noncomplementary DNA target strand, based on miR-21, showed very little response, indicating a highly sensitive and highly selective biosensing platform.
Collapse
Affiliation(s)
- Brian R. Dorvel
- Department of Biophysics and Computational Biology, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
- Micro and Nanotechnology Lab, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
| | - Bobby Reddy
- Department of Electrical and Computer Engineering, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
- Micro and Nanotechnology Lab, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
| | - Jonghyun Go
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN. 47906
| | - Carlos Duarte Guevara
- Department of Electrical and Computer Engineering, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
- Micro and Nanotechnology Lab, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
| | - Eric Salm
- Department of Bioengineering, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
- Micro and Nanotechnology Lab, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
| | - Muhammad Ashraful Alam
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN. 47906
| | - Rashid Bashir
- Department of Electrical and Computer Engineering, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
- Department of Bioengineering, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
- Micro and Nanotechnology Lab, University of Illinois at Urbana Champaign, Urbana, Illinois, 61801
| |
Collapse
|
32
|
Holford TR, Davis F, Higson SP. Recent trends in antibody based sensors. Biosens Bioelectron 2012; 34:12-24. [DOI: 10.1016/j.bios.2011.10.023] [Citation(s) in RCA: 203] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 10/06/2011] [Accepted: 10/13/2011] [Indexed: 12/29/2022]
|
33
|
Palmer SM, Kunji ERS. Online analysis and process control in recombinant protein production (review). Methods Mol Biol 2012; 866:129-155. [PMID: 22454120 DOI: 10.1007/978-1-61779-770-5_12] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Online analysis and control is essential for efficient and reproducible bioprocesses. A key factor in real-time control is the ability to measure critical variables rapidly. Online in situ measurements are the preferred option and minimize the potential loss of sterility. The challenge is to provide sensors with a good lifespan that withstand harsh bioprocess conditions, remain stable for the duration of a process without the need for recalibration, and offer a suitable working range. In recent decades, many new techniques that promise to extend the possibilities of analysis and control, not only by providing new parameters for analysis, but also through the improvement of accepted, well practiced, measurements have arisen.
Collapse
Affiliation(s)
- Shane M Palmer
- Mitochondrial Biology Unit, The Medical Research Council, Cambridge, UK
| | | |
Collapse
|
34
|
Advances in organic transistor-based biosensors: from organic electrochemical transistors to electrolyte-gated organic field-effect transistors. Anal Bioanal Chem 2011; 402:1813-26. [PMID: 21910013 DOI: 10.1007/s00216-011-5363-y] [Citation(s) in RCA: 214] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2011] [Revised: 08/04/2011] [Accepted: 08/24/2011] [Indexed: 11/26/2022]
Abstract
Organic electronics have, over the past two decades, developed into an exciting area of research and technology to replace classic inorganic semiconductors. Organic photovoltaics, light-emitting diodes, and thin-film transistors are already well developed and are currently being commercialized for a variety of applications. More recently, organic transistors have found new applications in the field of biosensors. The progress made in this direction is the topic of this review. Various configurations are presented, with their detection principle, and illustrated by examples from the literature.
Collapse
|
35
|
Safari S, Selvaganapathy PR, Derardja A, Deen MJ. Electrochemical growth of high-aspect ratio nanostructured silver chloride on silver and its application to miniaturized reference electrodes. NANOTECHNOLOGY 2011; 22:315601. [PMID: 21727314 DOI: 10.1088/0957-4484/22/31/315601] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The sensitivity of many biological and chemical sensors is critically dependent on the stability of the potential of the reference electrode being used. The stability of a reference electrode's potential is highly influenced by the properties of its surface. In this paper, for the first time, the formation of nanosheets of silver chloride on silver wire is observed and controlled using high anodic constant potential (>0.5 V) and pulsed electrodeposition. The resulting nanostructured morphology substantially improves the electrode's potential stability in comparison with the conventional globular surface structure. The increased stability is attributed to the increase in the surface area of the silver chloride produced by the nanosheet formation.
Collapse
Affiliation(s)
- S Safari
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada
| | | | | | | |
Collapse
|
36
|
Wu MH, Lee YF, Lin CW, Tsai SW, Wang HY, Pan TM. Development of high-kTm2Ti2O7 sensing membrane-based electrolyte–insulator–semiconductor for pH detection and its application for glucose biosensing using poly(N-isopropylacrylamide) as an enzyme encapsulation material. ACTA ACUST UNITED AC 2011. [DOI: 10.1039/c0jm02390f] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
37
|
Miao Y, He N, Zhu JJ. History and New Developments of Assays for Cholinesterase Activity and Inhibition. Chem Rev 2010; 110:5216-34. [DOI: 10.1021/cr900214c] [Citation(s) in RCA: 189] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Yuqing Miao
- Lab of Biomimetic Electrochemistry and Biosensors, Institute of Physical Chemistry, College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China; State Key Laboratory of Bioelectronics (Chien-Shiung Wu Laboratory), Southeast University, Nanjing 210096, China; MOE Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Nongyue He
- Lab of Biomimetic Electrochemistry and Biosensors, Institute of Physical Chemistry, College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China; State Key Laboratory of Bioelectronics (Chien-Shiung Wu Laboratory), Southeast University, Nanjing 210096, China; MOE Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Jun-Jie Zhu
- Lab of Biomimetic Electrochemistry and Biosensors, Institute of Physical Chemistry, College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China; State Key Laboratory of Bioelectronics (Chien-Shiung Wu Laboratory), Southeast University, Nanjing 210096, China; MOE Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
38
|
Organic ISFET based on poly (3-hexylthiophene). SENSORS 2010; 10:2262-73. [PMID: 22294926 PMCID: PMC3264479 DOI: 10.3390/s100302262] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2010] [Revised: 02/13/2010] [Accepted: 03/10/2010] [Indexed: 11/16/2022]
Abstract
We have fabricated organic field-effect transistors (OFETs) with regioregular poly(3-hexylthiophene) (P3HT) operable at low-voltages in liquid solutions, suitable for in vitro biosensing applications. Measurements in electrolytes have shown that the performance of the transistors did not deteriorate and they can be directly used as ion-sensitive transducers. Furthermore, more complex media have been tested, with the perspective of cell analysis. Degradation effects acting on the device operating in liquid could be partly compensated by adopting an alternate current measuring mode.
Collapse
|
39
|
Shalev G, Halpern E, Doron A, Cohen A, Rosenwaks Y, Levy I. Surface chemical modification induces nanometer scale electron confinement in field effect device. J Chem Phys 2009; 131:024702. [PMID: 19604005 DOI: 10.1063/1.3167414] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Design, preparation, and study of physicochemical properties of molecular assemblies are extremely challenging multidisciplinary research fields. Understanding the elementary principles that correlate these properties with molecular level of electronic behavior will enable us to control basic properties of molecule-based compounds as well as of classical semiconductors. In particular, chemical modification of field effect sensor devices where the metal gate is replaced with organic molecular layer, projects a crucial impact upon the electrical properties of the sensor. In these cases it is important to control the effects in order to ensure that the organic gate is optimized for sensing. Here we used fully depleted silicon-on-insulator (SOI) ion sensitive field effect transistor in order to analyze the projection of surface chemical modification on electronic performance. We suggest that surface activation and the application of 3-aminopropyltrimethoxysilane on top of the gate dielectric introduces negative charge at the Si/SiO(2) interface or/and on top of the gate dielectric and consequently an accumulation layer that confines the electrons to the bottom of the SOI channel. The transistor gain postmodification is characteristic of volume inversion, and therefore suggests that, following modification, the channel electrons are confined to SOI thickness of <10 nm. Finally, measurements of pH sensitivity indicate that the pH sensitivity post-UV/O(3) treatment is maximized suggesting that the negative charge is introduced during the activation process, where the density of the negatively charged amphoteric sites maximized.
Collapse
Affiliation(s)
- Gil Shalev
- Intel Research Israel Laboratory, Intel Electronics, Jerusalem 91031, Israel
| | | | | | | | | | | |
Collapse
|
40
|
Ion-sensitive field-effect transistor for biological sensing. SENSORS 2009; 9:7111-31. [PMID: 22423205 PMCID: PMC3290489 DOI: 10.3390/s90907111] [Citation(s) in RCA: 163] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2009] [Revised: 08/27/2009] [Accepted: 08/31/2009] [Indexed: 12/12/2022]
Abstract
In recent years there has been great progress in applying FET-type biosensors for highly sensitive biological detection. Among them, the ISFET (ion-sensitive field-effect transistor) is one of the most intriguing approaches in electrical biosensing technology. Here, we review some of the main advances in this field over the past few years, explore its application prospects, and discuss the main issues, approaches, and challenges, with the aim of stimulating a broader interest in developing ISFET-based biosensors and extending their applications for reliable and sensitive analysis of various biomolecules such as DNA, proteins, enzymes, and cells.
Collapse
|
41
|
Wu MH, Lee CD, Pan TM. High dielectric constant PrYxOy sensing films electrolyte-insulator-semiconductor pH-sensor for the detection of urea. Anal Chim Acta 2009; 651:36-41. [DOI: 10.1016/j.aca.2009.08.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2009] [Revised: 08/05/2009] [Accepted: 08/07/2009] [Indexed: 10/20/2022]
|
42
|
Chandrasekaran A, Packirisamy M. Experimental investigation of evanescence-based infrared biodetection technique for micro-total-analysis systems. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:054050. [PMID: 19895151 DOI: 10.1117/1.3210766] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The advent of microoptoelectromechanical systems (MOEMS) and its integration with other technologies such as microfluidics, microthermal, immunoproteomics, etc. has led to the concept of an integrated micro-total-analysis systems (microTAS) or Lab-on-a-Chip for chemical and biological applications. Recently, research and development of microTAS have attained a significant growth rate over several biodetection sciences, in situ medical diagnoses, and point-of-care testing applications. However, it is essential to develop suitable biophysical label-free detection methods for the success, reliability, and ease of use of the microTAS. We proposed an infrared (IR)-based evanescence wave detection system on the silicon-on-insulator platform for biodetection with microTAS. The system operates on the principle of bio-optical interaction that occurs due to the evanescence of light from the waveguide device. The feasibility of biodetection has been experimentally investigated by the detection of horse radish peroxidase upon its reaction with hydrogen peroxide.
Collapse
Affiliation(s)
- Arvind Chandrasekaran
- Concordia University, Department of Mechanical Engineering, Optical-Bio Microsystems Laboratory, 1515 Street Catherine Ouest, Montreal, Quebec H3G 2W1, Canada.
| | | |
Collapse
|
43
|
Viswanathan S, Radecka H, Radecki J. Electrochemical biosensors for food analysis. MONATSHEFTE FUR CHEMIE 2009. [DOI: 10.1007/s00706-009-0143-5] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
44
|
Structural Properties and Sensing Characteristics of Thin Nd[sub 2]O[sub 3] Sensing Films for pH Detection. ACTA ACUST UNITED AC 2009. [DOI: 10.1149/1.3193552] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
45
|
Standard CMOS Fabrication of a Sensitive Fully Depleted Electrolyte-Insulator-Semiconductor Field Effect Transistor for Biosensor Applications. SENSORS 2009; 9:4366-79. [PMID: 22408530 PMCID: PMC3291915 DOI: 10.3390/s90604366] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2009] [Revised: 05/20/2009] [Accepted: 05/25/2009] [Indexed: 11/17/2022]
Abstract
Microfabricated semiconductor devices are becoming increasingly relevant for detection of biological and chemical components. The integration of active biological materials together with sensitive transducers offers the possibility of generating highly sensitive, specific, selective and reliable biosensors. This paper presents the fabrication of a sensitive, fully depleted (FD), electrolyte-insulator-semiconductor field-effect transistor (EISFET) made with a silicon-on-insulator (SOI) wafer of a thin 10-30 nm active SOI layer. Initial results are presented for device operation in solutions and for bio-sensing. Here we report the first step towards a high volume manufacturing of a CMOS-based biosensor that will enable various types of applications including medical and environmental sensing.
Collapse
|
46
|
Park HJ, Kim SK, Park K, Lyu HK, Lee CS, Chung SJ, Yun WS, Kim M, Chung BH. An ISFET biosensor for the monitoring of maltose-induced conformational changes in MBP. FEBS Lett 2008; 583:157-62. [PMID: 19059402 DOI: 10.1016/j.febslet.2008.11.039] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2008] [Revised: 11/19/2008] [Accepted: 11/21/2008] [Indexed: 10/21/2022]
Abstract
Here we describe an ion sensitive field effect transistor (ISFET) biosensor, which was designed to monitor directly the surface charge of structurally altered maltose binding protein (MBP) upon stimulation with maltose. This study is the first report of the application of a FET biosensor to the monitoring of conformationally changed proteins. Consequently, a significant drop in current on the basis of the charge-dependent capacitance measurement has been clearly observed in response to maltose, but not for the glucose control, thereby indicating that the substrate-specific conformational properties of the target protein could be successfully monitored using the ISFET. Collectively, our results clearly suggest that ISFET provide a high fidelity system for the detection of maltose-induced structural alterations in MBP.
Collapse
Affiliation(s)
- Hye-Jung Park
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 305-333, South Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
47
|
|
48
|
Enzyme field effect transistor (ENFET) for estimation of triglycerides using magnetic nanoparticles. Biosens Bioelectron 2008; 23:1708-14. [DOI: 10.1016/j.bios.2008.02.003] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2007] [Revised: 01/10/2008] [Accepted: 02/06/2008] [Indexed: 11/21/2022]
|
49
|
Gustavsson J, Altankov G, Errachid A, Samitier J, Planell JA, Engel E. Surface modifications of silicon nitride for cellular biosensor applications. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2008; 19:1839-1850. [PMID: 18219554 DOI: 10.1007/s10856-008-3384-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2007] [Accepted: 12/28/2007] [Indexed: 05/25/2023]
Abstract
Thin films of silicon nitride (Si3N4) can be used in several kinds of micro-sized biosensors as a material to monitor fine environmental changes related to the process of bone formation in vitro. We found however that Si3N4 does not provide optimal conditions for osseointegration as osteoblast-like MG-63 cells tend to detach from the surface when cultured over confluence. Therefore Si3N4 was modified with self-assembled monolayers bearing functional end groups of primary amine (NH2) and carboxyl (COOH) respectively. Both these modifications enhanced the interaction with confluent cell layers and thus improve osseointegration over Si3N4. Furthermore it was observed that the NH2 functionality increased the adsorption of fibronectin (FN), promoted cell proliferation, but delayed the differentiation. We also studied the fate of pre-adsorbed and secreted FN from cells to learn more about the impact of above functionalities for the development of provisional extracellular matrix on materials interface. Taken together our data supports that Si3N4 has low tissue integration but good cellular biocompatibility and thus is appropriate in cellular biosensor applications such as the ion-sensitive field effect transistor (ISFET). COOH and NH2 chemistries generally improve the interfacial tissue interaction with the sensor and they are therefore suitable substrates for monitoring cellular growth or matrix deposition using electrical impedance spectroscopy.
Collapse
Affiliation(s)
- Johan Gustavsson
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Universitat Politècnica de Catalunya, Avda. Diagonal 647, Barcelona 08028, Spain
| | | | | | | | | | | |
Collapse
|
50
|
McKinley BA. ISFET and fiber optic sensor technologies: in vivo experience for critical care monitoring. Chem Rev 2008; 108:826-44. [PMID: 18179258 DOI: 10.1021/cr068120y] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Bruce A McKinley
- Department of Surgery, The Methodist Hospital, Houston, TX 77030, USA.
| |
Collapse
|