1
|
Yao J, Crockett J, D'Souza M, A Day G, K Wilcox R, C Jones A, Mengoni M. Effect of meniscus modelling assumptions in a static tibiofemoral finite element model: importance of geometry over material. Biomech Model Mechanobiol 2024; 23:1055-1065. [PMID: 38349433 PMCID: PMC11101373 DOI: 10.1007/s10237-024-01822-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/06/2024] [Indexed: 05/18/2024]
Abstract
Finite element studies of the tibiofemoral joint have increased use in research, with attention often placed on the material models. Few studies assess the effect of meniscus modelling assumptions in image-based models on contact mechanics outcomes. This work aimed to assess the effect of modelling assumptions of the meniscus on knee contact mechanics and meniscus kinematics. A sensitivity analysis was performed using three specimen-specific tibiofemoral models and one generic knee model. The assumptions in representing the meniscus attachment on the tibia (shape of the roots and position of the attachment), the material properties of the meniscus, the shape of the meniscus and the alignment of the joint were evaluated, creating 40 model instances. The values of material parameters for the meniscus and the position of the root attachment had a small influence on the total contact area but not on the meniscus displacement or the force balance between condyles. Using 3D shapes to represent the roots instead of springs had a large influence in meniscus displacement but not in knee contact area. Changes in meniscus shape and in knee alignment had a significantly larger influence on all outcomes of interest, with differences two to six times larger than those due to material properties. The sensitivity study demonstrated the importance of meniscus shape and knee alignment on meniscus kinematics and knee contact mechanics, both being more important than the material properties or the position of the roots. It also showed that differences between knees were large, suggesting that clinical interpretations of modelling studies using single geometries should be avoided.
Collapse
Affiliation(s)
- Jiacheng Yao
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - John Crockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Mathias D'Souza
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Gavin A Day
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Ruth K Wilcox
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Alison C Jones
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Marlène Mengoni
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK.
| |
Collapse
|
2
|
Yan M, Liang T, Zhao H, Bi Y, Wang T, Yu T, Zhang Y. Model Properties and Clinical Application in the Finite Element Analysis of Knee Joint: A Review. Orthop Surg 2024; 16:289-302. [PMID: 38174410 PMCID: PMC10834231 DOI: 10.1111/os.13980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/21/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
The knee is the most complex joint in the human body, including bony structures like the femur, tibia, fibula, and patella, and soft tissues like menisci, ligaments, muscles, and tendons. Complex anatomical structures of the knee joint make it difficult to conduct precise biomechanical research and explore the mechanism of movement and injury. The finite element model (FEM), as an important engineering analysis technique, has been widely used in many fields of bioengineering research. The FEM has advantages in the biomechanical analysis of objects with complex structures. Researchers can use this technology to construct a human knee joint model and perform biomechanical analysis on it. At the same time, finite element analysis can effectively evaluate variables such as stress, strain, displacement, and rotation, helping to predict injury mechanisms and optimize surgical techniques, which make up for the shortcomings of traditional biomechanics experimental research. However, few papers introduce what material properties should be selected for each anatomic structure of knee FEM to meet different research purposes. Based on previous finite element studies of the knee joint, this paper summarizes various modeling strategies and applications, serving as a reference for constructing knee joint models and research design.
Collapse
Affiliation(s)
- Mingyue Yan
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Ting Liang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Haibo Zhao
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Yanchi Bi
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Tianrui Wang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Tengbo Yu
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
- Department of Orthopedic Surgery, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, China
| | - Yingze Zhang
- Department of Orthopedics, The Third Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
3
|
Nesbitt DQ, Burruel DE, Henderson BS, Lujan TJ. Finite element modeling of meniscal tears using continuum damage mechanics and digital image correlation. Sci Rep 2023; 13:4039. [PMID: 36899069 PMCID: PMC10006193 DOI: 10.1038/s41598-023-29111-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 01/31/2023] [Indexed: 03/12/2023] Open
Abstract
Meniscal tears are a common, painful, and debilitating knee injury with limited treatment options. Computational models that predict meniscal tears may help advance injury prevention and repair, but first these models must be validated using experimental data. Here we simulated meniscal tears with finite element analysis using continuum damage mechanics (CDM) in a transversely isotropic hyperelastic material. Finite element models were built to recreate the coupon geometry and loading conditions of forty uniaxial tensile experiments of human meniscus that were pulled to failure either parallel or perpendicular to the preferred fiber orientation. Two damage criteria were evaluated for all experiments: von Mises stress and maximum normal Lagrange strain. After we successfully fit all models to experimental force-displacement curves (grip-to-grip), we compared model predicted strains in the tear region at ultimate tensile strength to the strains measured experimentally with digital image correlation (DIC). In general, the damage models underpredicted the strains measured in the tear region, but models using von Mises stress damage criterion had better overall predictions and more accurately simulated experimental tear patterns. For the first time, this study has used DIC to expose strengths and weaknesses of using CDM to model failure behavior in soft fibrous tissue.
Collapse
Affiliation(s)
- Derek Q Nesbitt
- Biomedical Engineering Doctoral Program, Boise State University, Boise, ID, USA
| | - Dylan E Burruel
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID, 83725-2085, USA
| | - Bradley S Henderson
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID, 83725-2085, USA
| | - Trevor J Lujan
- Department of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID, 83725-2085, USA.
| |
Collapse
|
4
|
De Rosa M, Filippone G, Best TM, Jackson AR, Travascio F. Mechanical properties of meniscal circumferential fibers using an inverse finite element analysis approach. J Mech Behav Biomed Mater 2022; 126:105073. [PMID: 34999488 PMCID: PMC9162054 DOI: 10.1016/j.jmbbm.2022.105073] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/20/2021] [Accepted: 01/02/2022] [Indexed: 02/03/2023]
Abstract
The extracellular matrix (ECM) of the meniscus is a gel-like water solution of proteoglycans embedding bundles of collagen fibers mainly oriented circumferentially. Collagen fibers significantly contribute to meniscal mechanics, however little is known about their mechanical properties. The objective of this study was to propose a constitutive model for collagen fibers embedded in the ECM of the meniscus and to characterize the tissue's pertinent mechanical properties. It was hypothesized that a linear fiber reinforced viscoelastic constitutive model is suitable to describe meniscal mechanical behavior in shear. It was further hypothesized that the mechanical properties governing the model depend on the tissue's composition. Frequency sweep tests were conducted on eight porcine meniscal specimens. A first cohort of experimental data resulted from tissue specimens where collagen fibers oriented parallel with respect to the shear plane were used. This was done to eliminate the contribution of collagen fibers from the mechanical response and characterize the mechanical properties of the ECM. A second cohort with fibers orthogonally oriented with respect to the shear plane that were used to determine the elastic properties of the collagen fibers via inverse finite element analysis. Our testing protocol revealed that tissue ECM mechanical behavior could be described by a generalized Maxwell model with 3 relaxation times. The inverse finite element analysis suggested that collagen fibers can be modeled as linear elastic elements having an average elastic modulus of 287.5 ± 62.6 MPa. Magnitudes of the mechanical parameters governing the ECM and fibers were negatively related to tissue water content.
Collapse
Affiliation(s)
- Massimiliano De Rosa
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL
| | - Giovanni Filippone
- Department of Materials Engineering, University of Naples Federico II, Naples, Italy
| | - Thomas M. Best
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL,UHealth Sports Medicine Institute, Coral Gables, FL,Department of Orthopaedic Surgery, University of Miami, Miami, FL
| | - Alicia R. Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL,Corresponding authors: Dr. Francesco Travascio, Associate Professor, College of Engineering, University of Miami, 1251 Memorial Drive, MEB 276, Coral Gables, FL 33146, USA, Telephone: +1-(305)-284-2371, , Dr. Alicia R. Jackson, Associate Professor, College of Engineering, University of Miami, 1251 Memorial Drive, MEA 219, Coral Gables, FL 33146, USA, Telephone: +1-(305)-284-2135,
| | - Francesco Travascio
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL,Department of Orthopaedic Surgery, University of Miami, Miami, FL,Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL,Corresponding authors: Dr. Francesco Travascio, Associate Professor, College of Engineering, University of Miami, 1251 Memorial Drive, MEB 276, Coral Gables, FL 33146, USA, Telephone: +1-(305)-284-2371, , Dr. Alicia R. Jackson, Associate Professor, College of Engineering, University of Miami, 1251 Memorial Drive, MEA 219, Coral Gables, FL 33146, USA, Telephone: +1-(305)-284-2135,
| |
Collapse
|
5
|
Ravoor J, Thangavel M, Elsen S R. Comprehensive Review on Design and Manufacturing of Bio-scaffolds for Bone Reconstruction. ACS APPLIED BIO MATERIALS 2021; 4:8129-8158. [PMID: 35005929 DOI: 10.1021/acsabm.1c00949] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Bio-scaffolds are synthetic entities widely employed in bone and soft-tissue regeneration applications. These bio-scaffolds are applied to the defect site to provide support and favor cell attachment and growth, thereby enhancing the regeneration of the defective site. The progressive research in bio-scaffold fabrication has led to identification of biocompatible and mechanically stable materials. The difficulties in obtaining grafts and expenditure incurred in the transplantation procedures have also been overcome by the implantation of bio-scaffolds. Drugs, cells, growth factors, and biomolecules can be embedded with bio-scaffolds to provide localized treatments. The right choice of materials and fabrication approaches can help in developing bio-scaffolds with required properties. This review mostly focuses on the available materials and bio-scaffold techniques for bone and soft-tissue regeneration application. The first part of this review gives insight into the various classes of biomaterials involved in bio-scaffold fabrication followed by design and simulation techniques. The latter discusses the various additive, subtractive, hybrid, and other improved techniques involved in the development of bio-scaffolds for bone regeneration applications. Techniques involving multimaterial printing and multidimensional printing have also been briefly discussed.
Collapse
Affiliation(s)
- Jishita Ravoor
- School of Mechanical Engineering Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| | - Mahendran Thangavel
- School of Mechanical Engineering Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| | - Renold Elsen S
- School of Mechanical Engineering Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| |
Collapse
|
6
|
Mohamadi A, Momenzadeh K, Masoudi A, Walley KC, Ierardi K, Ramappa A, DeAngelis JP, Nazarian A. Evolution of knowledge on meniscal biomechanics: a 40 year perspective. BMC Musculoskelet Disord 2021; 22:625. [PMID: 34266442 PMCID: PMC8283839 DOI: 10.1186/s12891-021-04492-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 06/21/2021] [Indexed: 02/08/2023] Open
Abstract
Background Knowledge regarding the biomechanics of the meniscus has grown exponentially throughout the last four decades. Numerous studies have helped develop this knowledge, but these studies have varied widely in their approach to analyzing the meniscus. As one of the subcategories of mechanical phenomena Medical Subject Headings (MeSH) terms, mechanical stress was introduced in 1973. This study aims to provide an up-to-date chronological overview and highlights the evolutionary comprehension and understanding of meniscus biomechanics over the past forty years. Methods A literature review was conducted in April 2021 through PubMed. As a result, fifty-seven papers were chosen for this narrative review and divided into categories; Cadaveric, Finite element (FE) modeling, and Kinematic studies. Results Investigations in the 1970s and 1980s focused primarily on cadaveric biomechanics. These studies have generated the fundamental knowledge basis for the emergence of FE model studies in the 1990s. As FE model studies started to show comparable results to the gold standard cadaveric models in the 2000s, the need for understanding changes in tissue stress during various movements triggered the start of cadaveric and FE model studies on kinematics. Conclusion This study focuses on a chronological examination of studies on meniscus biomechanics in order to introduce concepts, theories, methods, and developments achieved over the past 40 years and also to identify the likely direction for future research. The biomechanics of intact meniscus and various types of meniscal tears has been broadly studied. Nevertheless, the biomechanics of meniscal tears, meniscectomy, or repairs in the knee with other concurrent problems such as torn cruciate ligaments or genu-valgum or genu-varum have not been extensively studied.
Collapse
Affiliation(s)
- Amin Mohamadi
- Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, RN123, Boston, MA, 02215, USA.,Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Kaveh Momenzadeh
- Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, RN123, Boston, MA, 02215, USA.,Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Aidin Masoudi
- Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, RN123, Boston, MA, 02215, USA
| | - Kempland C Walley
- Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, RN123, Boston, MA, 02215, USA.,Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Kenny Ierardi
- Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, RN123, Boston, MA, 02215, USA
| | - Arun Ramappa
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Joseph P DeAngelis
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Ara Nazarian
- Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, RN123, Boston, MA, 02215, USA. .,Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA. .,Department of Orthopaedic Surgery, Yerevan State Medical University, Yerevan, Armenia.
| |
Collapse
|
7
|
Rocha de Faria JL, Pavão DM, Pires e Albuquerque RS, de Sousa EB, Guimarães JAM, Mozella ADP, Roesler CRDM, Salim R, Mandarino M, LaPrade RF. Continuous Meniscal Suture in Radial Meniscal Tear: The Hourglass Technique. Arthrosc Tech 2021; 10:e1763-e1772. [PMID: 34336574 PMCID: PMC8322627 DOI: 10.1016/j.eats.2021.03.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 03/18/2021] [Indexed: 02/03/2023] Open
Abstract
The key to preventing early knee osteoarthritis is meniscal preservation. The main functions of the meniscus are impact absorption, mechanical load transmission, lubrication, joint stability, and proprioception. Radial lesions that extend to the joint capsule are called complete radial tears. This type of injury compromises 2 of the main meniscal functions, which are impact absorption and load distribution, which is equivalent, from a biomechanical perspective, to a total meniscectomy. In the recent past, the treatment of choice for this type of injury was partial meniscectomy. However, several studies have observed progressive joint degeneration after this type of treatment. Recently, different types of meniscal sutures involving radial lesions of the meniscus have been developed. It is believed that such repairs may bring a decrease in future osteoarthritis in this patient profile. The purpose of this article is to describe the steps of continuous meniscal suture for the treatment of radial tears of the medial and lateral menisci.
Collapse
Affiliation(s)
- José Leonardo Rocha de Faria
- National Institute of Traumatology and Orthopedics of Brazil, Rio de Janeiro,Address correspondence to José Leonardo Rocha de Faria, Instituto Nacional de Traumatologia e Ortopedia Jamil Haddad - Av. Brasil, 500, São Cristovão, Rio de Janeiro - RJ. CEP: 20940-070.
| | - Douglas Mello Pavão
- National Institute of Traumatology and Orthopedics of Brazil, Rio de Janeiro
| | | | | | | | - Alan de Paula Mozella
- National Institute of Traumatology and Orthopedics of Brazil, Rio de Janeiro,Medical Science Faculty, State University of Rio de Janeiro, Rio de Janeiro
| | | | - Rodrigo Salim
- Clinical Hospital of Ribeirão Preto, School of Medicine, University of São Paulo – USP Riberão Preto, São Paulo, Brazil
| | - Marcelo Mandarino
- National Institute of Traumatology and Orthopedics of Brazil, Rio de Janeiro
| | - Robert F. LaPrade
- Twin Cities Orthopaedics, Edina,University of Minnesota Medical School, Minneapolis, Minnesota, U.S.A
| |
Collapse
|
8
|
Evolution of Meniscal Biomechanical Properties with Growth: An Experimental and Numerical Study. Bioengineering (Basel) 2021; 8:bioengineering8050070. [PMID: 34065530 PMCID: PMC8160968 DOI: 10.3390/bioengineering8050070] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/03/2021] [Accepted: 05/17/2021] [Indexed: 11/17/2022] Open
Abstract
The menisci of the knee are complex fibro-cartilaginous tissues that play important roles in load bearing, shock absorption, joint lubrication, and stabilization. The objective of this study was to evaluate the interaction between the different meniscal tissue components (i.e., the solid matrix constituents and the fluid phase) and the mechanical response according to the developmental stage of the tissue. Menisci derived from partially and fully developed pigs were analyzed. We carried out biochemical analyses to quantify glycosaminoglycan (GAG) and DNA content according to the developmental stage. These values were related to tissue mechanical properties that were measured in vitro by performing compression and tension tests on meniscal specimens. Both compression and tension protocols consisted of multi-ramp stress-relaxation tests comprised of increasing strains followed by stress-relaxation to equilibrium. To better understand the mechanical response to different directions of mechanical stimulus and to relate it to the tissue structural composition and development, we performed numerical simulations that implemented different constitutive models (poro-elasticity, viscoelasticity, transversal isotropy, or combinations of the above) using the commercial software COMSOL Multiphysics. The numerical models also allowed us to determine several mechanical parameters that cannot be directly measured by experimental tests. The results of our investigation showed that the meniscus is a non-linear, anisotropic, non-homogeneous material: mechanical parameters increase with strain, depend on the direction of load, and vary among regions (anterior, central, and posterior). Preliminary numerical results showed the predominant role of the different tissue components depending on the mechanical stimulus. The outcomes of biochemical analyses related to mechanical properties confirmed the findings of the numerical models, suggesting a specific response of meniscal cells to the regional mechanical stimuli in the knee joint. During maturation, the increase in compressive moduli could be explained by cell differentiation from fibroblasts to metabolically active chondrocytes, as indicated by the found increase in GAG/DNA ratio. The changes of tensile mechanical response during development could be related to collagen II accumulation during growth. This study provides new information on the changes of tissue structural components during maturation and the relationship between tissue composition and mechanical response.
Collapse
|
9
|
Biomechanical Performance of Menisci under Cyclic Loads. Appl Bionics Biomech 2021. [DOI: 10.1155/2021/5512762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The meniscus, composed of fibrocartilage, is a very important part of the human knee joint that behaves like a buffer. Located in the middle of the femoral condyles and the tibial plateau, it is a necessary structure to maintain normal biomechanical properties of the knee. Whether walking or exercising, the meniscus plays a vital role to protect the articular surface of both the femoral condyles and the tibial plateau by absorbing the conveying shock from body weight. However, modern people often suffer from irreversible degeneration of joint tissue due to exercise-induced harm or aging. Therefore, understanding its dynamic characteristics will help to learn more about the actual state of motion and to avoid unnecessary injury. This study uses reverse engineering equipment, a 3D optical scanner, and a plastic teaching human body model to build the geometry of knee joint meniscus. Then, the finite element method (FEM) is employed to obtain the dynamic characteristics of the meniscus. The results show the natural frequencies, mode shapes, and fatigue life analysis of meniscus, with real human material parameters. The achieved results can be applied to do subsequent knee dynamic simulation analysis, to reduce the knee joint and lower external impacts, and to manufacture artificial meniscus through tissue engineering.
Collapse
|
10
|
Non-anatomical placement adversely affects the functional performance of the meniscal implant: a finite element study. Biomech Model Mechanobiol 2021; 20:1167-1185. [PMID: 33661440 DOI: 10.1007/s10237-021-01440-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 02/17/2021] [Indexed: 01/14/2023]
Abstract
Non-anatomical placement may occur during the surgical implantation of the meniscal implant, and its influence on the resulting biomechanics of the knee joint has not been systematically studied. The purpose of this study was to evaluate the biomechanical effects of non-anatomical placement of the meniscal implant on the knee joint during a complete walking cycle. Three-dimensional finite element (FE) analyses of the knee joint were performed, based on the model developed from magnetic resonance images and the loading conditions derived from the gait pattern of a healthy male subject, for the following physiological conditions: (i) knee joint with intact native meniscus, (ii) medial meniscectomized knee joint, (iii) knee joint with anatomically placed meniscal implant, and (iv) knee joint with the meniscal implant placed in four different in vitro determined non-anatomical locations. While the native menisci were modeled using the nonlinear hyperelastic Holzapfel-Gasser-Ogden (HGO) constitutive model, the meniscal implant was modeled using the isotropic hyperelastic neo-Hookean model. Placement of the meniscal implant in the non-anatomical lateral-posterior and lateral-anterior locations significantly increased the peak contact pressure in the medial compartment. Placement of the meniscal implant in non-anatomical locations significantly altered the tibial rotational kinematics and increased the total force acting at the meniscal horns. Results suggest that placement of the meniscal implant in non-anatomical locations may restrain its ability to be chondroprotective and may initiate or accelerate cartilage degeneration. In conclusion, clinicians should endeavor to place the implant as closest as possible to the anatomical location to restore the normal knee biomechanics.
Collapse
|
11
|
Chen YN, Chuang CH, Yang TH, Chang CW, Li CT, Chang CJ, Chang CH. Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures. J Orthop Surg Res 2020; 15:409. [PMID: 32928260 PMCID: PMC7489014 DOI: 10.1186/s13018-020-01922-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 08/24/2020] [Indexed: 12/14/2022] Open
Abstract
Background Lateral hinge fracture (LHF) is associated with nonunion and plate breakage in high tibial osteotomy (HTO). Mechanical studies investigating fixation strategies for LHFs to restore stability and avoid plate breakage are absent. This study used computer simulation to compare mechanical stabilities in HTO for different LHFs fixed with medial and bilateral locking plates. Methods A finite element knee model was created with HTO and three types of LHF, namely T1, T2, and T3 fractures, based on the Takeuchi classification. Either medial plating or bilateral plating was used to fix the HTO with LHFs. Furthermore, the significance of the locking screw at the combi hole (D-hole) of the medial TomoFix plate was evaluated. Results The osteotomy gap shortening distance increased from 0.53 to 0.76, 0.79, and 0.72 mm after T1, T2, and T3 LHFs, respectively, with medial plating only. Bilateral plating could efficiently restore stability and maintain the osteotomy gap. Furthermore, using the D-hole screw reduced the peak stress on the medial plate by 28.7% (from 495 to 353 MPa), 26.6% (from 470 to 345 MPa), and 32.6% (from 454 to 306 MPa) in T1, T2, and T3 LHFs, respectively. Conclusion Bilateral plating is a recommended strategy to restore HTO stability in LHFs. Furthermore, using a D-hole locking screw is strongly recommended to reduce the stress on the medial plate for lowering plate breakage risk.
Collapse
Affiliation(s)
- Yen-Nien Chen
- Department of Physical Therapy, Asia University, 500, Lioufeng Rd., Wufeng, Taichung, 41354, Taiwan.
| | - Chang-Han Chuang
- Department of Orthopedics, Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Tai-Hua Yang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.,Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.,Skeleton Materials and Bio-compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan.,Department of Orthopedics, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Chih-Wei Chang
- Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan. .,Department of Orthopedics, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
| | - Chun-Ting Li
- Institute of Geriatric Welfare Technology & Science, Mackay Medical College, New Taipei City, Taiwan
| | - Chia-Jung Chang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Chih-Han Chang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|
12
|
Constitutive modeling of menisci tissue: a critical review of analytical and numerical approaches. Biomech Model Mechanobiol 2020; 19:1979-1996. [PMID: 32572727 DOI: 10.1007/s10237-020-01352-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 05/28/2020] [Indexed: 02/07/2023]
Abstract
Menisci are fibrocartilaginous disks consisting of soft tissue with a complex biomechanical structure. They are critical determinants of the kinematics as well as the stability of the knee joint. Several studies have been carried out to formulate tissue mechanical behavior, leading to the development of a wide spectrum of constitutive laws. In addition to developing analytical tools, extensive numerical studies have been conducted on menisci modeling. This study reviews the developments of the most widely used continuum models of the meniscus mechanical properties in conjunction with emerging analytical and numerical models used to study the meniscus. The review presents relevant approaches and assumptions used to develop the models and includes discussions regarding strengths, weaknesses, and discrepancies involved in the presented models. The study presents a comprehensive coverage of relevant publications included in Compendex, EMBASE, MEDLINE, PubMed, ScienceDirect, Springer, and Scopus databases. This review aims at opening novel avenues for improving menisci modeling within the framework of constitutive modeling through highlighting the needs for further research directed toward determining key factors in gaining insight into the biomechanics of menisci which is crucial for the elaborate design of meniscal replacements.
Collapse
|
13
|
Naghibi H, Janssen D, van den Boogaard T, van Tienen T, Verdonschot N. The implications of non-anatomical positioning of a meniscus prosthesis on predicted human knee joint biomechanics. Med Biol Eng Comput 2020; 58:1341-1355. [PMID: 32279202 PMCID: PMC7211793 DOI: 10.1007/s11517-020-02158-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 03/12/2020] [Indexed: 11/26/2022]
Abstract
Despite all the efforts to optimize the meniscus prosthesis system (geometry, material, and fixation type), the success of the prosthesis in clinical practice will depend on surgical factors such as intra-operative positioning of the prosthesis. In this study, the aim was therefore to assess the implications of positional changes of the medial meniscus prosthesis for knee biomechanics. A detailed validated finite element (FE) model of human intact and meniscal implanted knees was developed based on a series of in vitro experiments. Different non-anatomical prosthesis positions were applied in the FE model, and the biomechanical response during the gait stance phase compared with an anatomically positioned prosthesis, as well as meniscectomized and also the intact knee model. The results showed that an anatomical positioning of the medial meniscus prosthesis could better recover the intact knee biomechanics, while a non-anatomical positioning of the prosthesis to a limited extent alters the knee kinematics and articular contact pressure and increases the implantation failure risk. The outcomes indicate that a medial or anterior positioning of the meniscus prosthesis may be more forgiving than a posteriorly or laterally positioned prosthesis. The outcome of this study may provide a better insight into the possible consequences of meniscus prosthesis positioning errors for the patient and the prosthesis functionality. Graphical abstract ![]()
Collapse
Affiliation(s)
- Hamid Naghibi
- Robotics and Mechatronics Lab, Technical Medical (TechMed) Centre, University of Twente, Building Carré, Room CR 3607, P.O. Box 217, 7500 AE, Enschede, The Netherlands.
- Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands.
| | - Dennis Janssen
- Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands
| | - Ton van den Boogaard
- Nonlinear Solid Mechanics, Faculty of Engineering Technology, University of Twente, 7522 NB, Enschede, The Netherlands
| | - Tony van Tienen
- Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands
| | - Nico Verdonschot
- Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands
- Laboratory of Biomechanical Engineering, University of Twente, 7522 NB, Enschede, The Netherlands
| |
Collapse
|
14
|
Cooper RJ, Wilcox RK, Jones AC. Finite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges. Med Eng Phys 2019; 74:1-12. [DOI: 10.1016/j.medengphy.2019.08.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 08/05/2019] [Accepted: 08/21/2019] [Indexed: 12/20/2022]
|
15
|
"Horizontal butterfly" technique in repair of radial meniscus tears: A biomechanical study. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA 2018; 52:392-396. [PMID: 30120005 PMCID: PMC6204466 DOI: 10.1016/j.aott.2018.07.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 05/19/2018] [Accepted: 07/26/2018] [Indexed: 01/14/2023]
Abstract
Introduction Radial meniscus tears are seen in young patients, especially with anterior cruciate ligament ruptures. Repair of complete radial meniscus tear is necessary for the meniscus functions. The most important factor for success of the meniscus repair is primary stability, but it is still unknown which technique is ideal repair technique. Aim We developed a new suture technique named Horizontal Butterfly (HB). In this novel technique the contact between meniscal tissue and suture is more than Horizontal Loop (HL) that routinely used today. So, we think that this technique will provide better fixation than HL. We aimed to compare 2 repair techniques (HB vs. HL) using human lateral menisci biomechanically with cyclic loading and load to failure tests. Material-method We used 22 intact lateral meniscus obtained from patients that operated (total knee replacement) for varus gonarthrosis in our clinic. All menisci were cut radially. In the first group (n:11) menisci were repaired with standard horizontal loop technique, and in the second group (n:11) horizontal butterfly technique were used for repair. All specimens were tested with load to failure test after cyclic loading test (500 cycle X 5–30 N). Results Both groups have similar failure load (71,4 ± 17,52 N vs. 77,9 ± 28,49 N; p:0,559) and stiffness (24,46 ± 19,19 N vs. 24,48 ± 15,87 N; p:0,818). HB group has less peak displacement (6,26 ± 1,24 mm vs. 8,4 ± 1,92 mm; p:0,010). Conclusion This novel repair technique decreases the amount of displacement according to standard technique while as strong as standard technique routinely used. In this way; we believe that it will increase the rate of healing in clinical use.
Collapse
|
16
|
Stender ZC, Cracchiolo AM, Walsh MP, Patterson DP, Wilusz MJ, Lemos SE. Radial Tears of the Lateral Meniscus-Two Novel Repair Techniques: A Biomechanical Study. Orthop J Sports Med 2018; 6:2325967118768086. [PMID: 29780840 PMCID: PMC5954321 DOI: 10.1177/2325967118768086] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Background: A common treatment for radial tears of the meniscus has historically been partial meniscectomy. Owing to the poor outcomes associated with partial meniscectomy, repair of the meniscus is an important treatment option. It is important to evaluate different repair techniques for radial tears of the meniscus. Purpose/Hypothesis: The purpose of this study was to evaluate 2 novel techniques to repair radial tears of the lateral meniscus. The 2 techniques were compared biomechanically with the cross-suture method with an inside-out technique. The authors hypothesized that novel repair techniques would result in less displacement after cyclic loading, increased load required to displace the repair 3 mm, greater load to failure, decreased displacement at load to failure, and increased stiffness of the repair, resulting in a construct that more closely re-creates the function of the intact meniscus. Study Design: Controlled laboratory study. Methods: A total of 36 fresh-frozen cadaveric tibial plateaus containing intact menisci were obtained. The menisci were divided into 3 groups (n = 12 in each group), and each meniscus was repaired simulating an inside-out technique. The 3 repairs completed were the hashtag, crosstag, and cross-suture techniques. Radial tears were created at the midbody of the lateral meniscus and repaired via the 3 techniques. The repaired menisci were attached to an axial loading machine and tested for cyclic and failure loading. Results: After cyclic loading, the cross-suture repair displaced 4.78 ± 1.65 mm; the hashtag, 2.42 ± 1.13 mm; and the crosstag, 3.13 ± 1.77 mm. The hashtag and cross-tag repairs both resulted in significantly less displacement (P = .003 and .024, respectively) as compared with the cross-suture repair. The cross-suture technique had a load to failure of 81.43 ± 14.31 N; the hashtag, 86.08 ± 23.58 N; and the crosstag, 62.50 ± 12.15 N. The cross-suture and hashtag repairs both resulted in a greater load to failure when compared with the crosstag (P = .009 and .009, respectively). There was no difference comparing the load required to displace the cross-suture technique 3 mm versus the hashtag or crosstag technique (P = .564 and .094, respectively). However, when compared with the crosstag technique, the hashtag technique required a significantly greater load to displace the repair 3 mm (P = .015). Conclusion: This study introduced 2 novel repair techniques—hashtag and crosstag—that did not demonstrate superiority in terms of load to failure or stiffness, but both repairs were statistically superior to the cross-suture repair in terms of displacement after cyclic loading. Considerations that may influence the validity of these techniques include cost, surgical time, and increased technical demand. Clinical Relevance: Radial tears of the meniscus are difficult to repair. Further research into more stable constructs is necessary.
Collapse
|
17
|
Luczkiewicz P, Daszkiewicz K, Witkowski W, Chróścielewski J, Ferenc T, Baczkowski B. The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion. PLoS One 2018; 13:e0193020. [PMID: 29447236 PMCID: PMC5814050 DOI: 10.1371/journal.pone.0193020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Accepted: 02/02/2018] [Indexed: 01/09/2023] Open
Abstract
OBJECTIVE The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. METHODS One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then prepared. Nonlinear static analyses with a fixed flexion/extension movement for a compressive load of 1000 N were performed. The additional analyses for those models with a constrained medio-lateral relative bone translation allowed for an evaluation of the influence of this translation on a meniscus external shift. RESULTS It was observed that a decrease in the meniscus height caused a decrease in the contact area, together with a decrease in the contact force between the flattened meniscus and the cartilage. For the models with an increased meniscus height, a maximal value of force acting on the meniscus in a medio-lateral direction was obtained. The results have shown that the meniscus external shift was approximately proportional to the meniscus slope angle, but that relationship was modified by a medio-lateral relative bone translation. It was found that the translation of the femur relative to the tibia may be dependent on the geometry of the menisci. CONCLUSIONS The results have suggested that a change in the meniscus geometry in the cross sectional plane can considerably affect not only the meniscal external shift, but also the medio-lateral translation of the knee joint as well as the congruency of the knee joint.
Collapse
MESH Headings
- Adult
- Biomechanical Phenomena
- Cartilage, Articular/anatomy & histology
- Cartilage, Articular/diagnostic imaging
- Cartilage, Articular/physiology
- Female
- Finite Element Analysis
- Humans
- Imaging, Three-Dimensional
- Knee Joint/anatomy & histology
- Knee Joint/diagnostic imaging
- Knee Joint/physiology
- Magnetic Resonance Imaging
- Menisci, Tibial/anatomy & histology
- Menisci, Tibial/diagnostic imaging
- Menisci, Tibial/physiology
- Models, Anatomic
- Models, Biological
- Stress, Mechanical
Collapse
Affiliation(s)
- Piotr Luczkiewicz
- II Clinic of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdansk, Gdansk, Poland
- * E-mail:
| | - Karol Daszkiewicz
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Wojciech Witkowski
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Jacek Chróścielewski
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Tomasz Ferenc
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland
| | - Boguslaw Baczkowski
- II Clinic of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdansk, Gdansk, Poland
| |
Collapse
|
18
|
Meng Q, Fisher J, Wilcox R. The effects of geometric uncertainties on computational modelling of knee biomechanics. ROYAL SOCIETY OPEN SCIENCE 2017; 4:170670. [PMID: 28879008 PMCID: PMC5579124 DOI: 10.1098/rsos.170670] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Accepted: 07/17/2017] [Indexed: 06/07/2023]
Abstract
The geometry of the articular components of the knee is an important factor in predicting joint mechanics in computational models. There are a number of uncertainties in the definition of the geometry of cartilage and meniscus, and evaluating the effects of these uncertainties is fundamental to understanding the level of reliability of the models. In this study, the sensitivity of knee mechanics to geometric uncertainties was investigated by comparing polynomial-based and image-based knee models and varying the size of meniscus. The results suggested that the geometric uncertainties in cartilage and meniscus resulting from the resolution of MRI and the accuracy of segmentation caused considerable effects on the predicted knee mechanics. Moreover, even if the mathematical geometric descriptors can be very close to the imaged-based articular surfaces, the detailed contact pressure distribution produced by the mathematical geometric descriptors was not the same as that of the image-based model. However, the trends predicted by the models based on mathematical geometric descriptors were similar to those of the imaged-based models.
Collapse
Affiliation(s)
- Qingen Meng
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | | | | |
Collapse
|
19
|
High meniscal slope angle as a risk factor for meniscal allograft extrusion. Med Hypotheses 2017; 101:48-51. [PMID: 28351490 DOI: 10.1016/j.mehy.2017.02.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Accepted: 02/08/2017] [Indexed: 12/16/2022]
Abstract
A meniscal graft extrusion is still an unresolved problem that affects most patients after a meniscal transplantation. Despite the advances in surgical techniques, together with the improved methods for a meniscal allograft sizing, success is only observed in up to 75% of patients after they experience a meniscal allograft transplantation. Because a meniscal extrusion is associated with a cartilage deterioration and the progression of osteoarthritis there is a great interest in how to prevent this phenomenon. The crucial factor for the minimisation of a meniscal allograft extrusion is by perfectly matching the implant. Most methods for a meniscal allograft sizing only focus on assessing the length and the width of the meniscus. Even though there is some evidence that there is a relationship between the shape of the meniscus in a cross-sectional plane and the meniscal extrusion, any of the planning methods do not take this factor into consideration. Although there is a large variability of meniscus shapes in cross-section, we hypothesise that by taking the meniscal slope into account during surgical planning, as well as performing the correct adjustments of this particular parameter, we can diminish the risk of a meniscal allograft extrusion.
Collapse
|
20
|
Anisotropy in the viscoelastic response of knee meniscus cartilage. J Appl Biomater Funct Mater 2017; 15:e77-e83. [PMID: 27647392 DOI: 10.5301/jabfm.5000319] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/30/2016] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND The knee meniscus is instrumental to stability, shock absorption, load transmission and stress distribution within the knee joint. Such functions are mechanically demanding, and replacement constructs used in meniscus repair often fail because of a poor match with the surrounding tissue. This study focused on the native structure-mechanics relationships and on their anisotropic behavior in meniscus, to define the target biomechanical viscoelastic properties required by scaffolds upon loading. METHODS To show regional orientation of the collagen fibers and their viscoelastic behavior, bovine lateral menisci were characterized by second harmonic generation microscopy and through time-dependent mechanical tests. Furthermore, their dynamic viscoelastic response was analyzed over a wide range of frequencies. RESULTS AND CONCLUSIONS Multilevel characterization aims to expand the biomimetic approach from the structure itself, to include the mechanical characteristics that give the meniscus its peculiar properties, thus providing tools for the design of novel, effective scaffolds. An example of modeling of anisotropic open-cell porous material tailored to fulfill the measured requirements is presented, leading to a definition of additional parameters for a better understanding of the load transmission mechanism and for better scaffold functionality.
Collapse
|
21
|
Łuczkiewicz P, Daszkiewicz K, Chróścielewski J, Witkowski W, Winklewski PJ. The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics. PLoS One 2016; 11:e0167733. [PMID: 27936066 PMCID: PMC5147969 DOI: 10.1371/journal.pone.0167733] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Accepted: 11/18/2016] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. METHODS The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis (OA) model. Two variants of medial knee OA model with congruent and incongruent contact surfaces were analysed to investigate the influence of congruency. A nonlinear static analysis for one compressive load case was performed. The focus of the study was the influence of cartilage degeneration on meniscal extrusion and the values of the contact forces and contact areas. RESULTS In the model with incongruent contact surfaces, we observed maximal compressive stress on the tibial plateau. In this model, the value of medial meniscus external shift was 95.3% greater, while the contact area between the tibial cartilage and medial meniscus was 50% lower than in the congruent contact surfaces model. After the non-uniform reduction of cartilage thickness, the medial meniscus carried only 48.4% of load in the medial compartment in comparison to 71.2% in the healthy knee model. CONCLUSIONS We have shown that the change in articular cartilage geometry may significantly reduce the role of meniscus in load transmission and the contact area between the meniscus and cartilage. Additionally, medial knee OA may increase the risk of meniscal extrusion in the medial compartment of the knee joint.
Collapse
Affiliation(s)
- Piotr Łuczkiewicz
- II Clinic of Orthopaedics and Kinetic Organ Traumatology, Medical University of Gdańsk, Gdańsk, Poland
- * E-mail:
| | - Karol Daszkiewicz
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Jacek Chróścielewski
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Wojciech Witkowski
- Department of Mechanics of Materials, Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Pawel J. Winklewski
- Institute of Human Physiology, Medical University of Gdańsk, Gdańsk, Poland
- Institute of Health Sciences, Pomeranian University of Słupsk, Słupsk, Poland
| |
Collapse
|
22
|
Lakes EH, Matuska AM, McFetridge PS, Allen KD. Mechanical Integrity of a Decellularized and Laser Drilled Medial Meniscus. J Biomech Eng 2016; 138:4032381. [PMID: 26720513 DOI: 10.1115/1.4032381] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Indexed: 12/31/2022]
Abstract
Since the meniscus has limited capacity to self-repair, creating a long-lasting meniscus replacement may help reduce the incidence of osteoarthritis (OA) after meniscus damage. As a first step toward this goal, this study evaluated the mechanical integrity of a decellularized, laser drilled (LD) meniscus as a potential scaffold for meniscal engineering. To evaluate the decellularization process, 24 porcine menisci were processed such that one half remained native tissue, while the other half was decellularized in sodium dodecyl sulphate (SDS). To evaluate the laser drilling process, 24 additional menisci were decellularized, with one half remaining intact while the other half was LD. Decellularization did not affect the tensile properties, but had significant effects on the cyclic compressive hysteresis and unconfined compressive stress relaxation. Laser drilling decreased the Young's modulus and instantaneous stress during unconfined stress relaxation and the circumferential ultimate strength during tensile testing. However, the losses in mechanical integrity in the LD menisci were generally smaller than the variance observed between samples, and thus, the material properties for the LD tissue remained within a physiological range. In the future, optimization of laser drilling patterns may improve these material properties. Moreover, reseeding the construct with cells may further improve the mechanical properties prior to implantation. As such, this work serves as a proof of concept for generating decellularized, LD menisci scaffolds for the purposes of meniscal engineering.
Collapse
|
23
|
Ghezelbash F, Shirazi-Adl A, Arjmand N, El-Ouaaid Z, Plamondon A, Meakin J. Effects of sex, age, body height and body weight on spinal loads: Sensitivity analyses in a subject-specific trunk musculoskeletal model. J Biomech 2016; 49:3492-3501. [DOI: 10.1016/j.jbiomech.2016.09.026] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Revised: 09/15/2016] [Accepted: 09/16/2016] [Indexed: 02/02/2023]
|
24
|
Freutel M, Galbusera F, Ignatius A, Dürselen L. Material properties of individual menisci and their attachments obtained through inverse FE-analysis. J Biomech 2015; 48:1343-9. [PMID: 25843259 DOI: 10.1016/j.jbiomech.2015.03.014] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Accepted: 03/10/2015] [Indexed: 10/23/2022]
Abstract
Meniscal properties for computational methods have already been proposed. However, it is well known that there is high intra subject variability in the material properties of soft tissues and that disruption of the fiber network alters the biomechanics of the meniscus. Therefore, the objective of this study was to establish a non invasive method to determine the material properties of the individual menisci and their attachments using inverse FE-analyses. In a previous study, the 3D displacements of the meniscus and its attachments under axial joint loads were determined for intact porcine knees. To simulate the experimental response in individual FE-analyses (n=5), an anisotropic, hyperelastic meniscus matrix was embedded in a poroelastic model. During a particle swarm optimization, the difference between the force applied to the meniscus during the experiment and the femoral surface reaction force of the FE model at equilibrium was minimized by varying four material parameters. Afterwards, a prediction error was determined to describe how well the material parameter fit to each of the three displacement directions. Additionally, the stresses occurring in the meniscus were evaluated. The error of the material parameter optimization was on average 6.5±4.4%. The best fitting material parameter combination revealed an error of 1.2%. The highest stresses occurred in the region between the pars intermedia and posterior horn of the meniscus. The individual material properties of the meniscus were successfully obtained with a combination of previously reported, noninvasively measured 3D displacements and inverse FE-analyses. The methodology presented in this study is a promising contribution to the detection of degeneration within the meniscus.
Collapse
Affiliation(s)
- Maren Freutel
- Institute of Orthopaedic Research and Biomechanics, Centre of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany.
| | - Fabio Galbusera
- Laboratory of Biological Structures Mechanics, IRCCS Galeazzi Orthopedic Institute, Milan, Italy
| | - Anita Ignatius
- Institute of Orthopaedic Research and Biomechanics, Centre of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany
| | - Lutz Dürselen
- Institute of Orthopaedic Research and Biomechanics, Centre of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany
| |
Collapse
|
25
|
Łuczkiewicz P, Daszkiewicz K, Witkowski W, Chróścielewski J, Zarzycki W. Influence of meniscus shape in the cross sectional plane on the knee contact mechanics. J Biomech 2015; 48:1356-63. [PMID: 25892539 DOI: 10.1016/j.jbiomech.2015.03.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Accepted: 03/07/2015] [Indexed: 11/17/2022]
Abstract
We present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with complete radial posterior meniscus root tear and knee with total meniscectomy of medial or lateral meniscus. We investigate how the meniscus shape in the cross sectional plane influences knee-joint mechanics by comparing the results for flat (degenerated) lateral and normal medial meniscus. Specifically, the deformation of the menisci in the coronal plane and the corresponding stress values in cartilages are studied. By analysing contact resultant force acting on the menisci in axial plane we have shown that restricted extrusion of the torn lateral meniscus can be attributed to small slope of its cross section in the coronal plane. Additionally, the change of the contact area and the resultant force acting on the menisci as the function of compressive load are investigated.
Collapse
Affiliation(s)
- Piotr Łuczkiewicz
- Medical University of Gdańsk, II Clinic of Orthopaedics and Kinetic Organ Traumatology, Poland
| | - Karol Daszkiewicz
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Structural Mechanics, Poland.
| | - Wojciech Witkowski
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Structural Mechanics, Poland
| | - Jacek Chróścielewski
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Structural Mechanics, Poland
| | - Witold Zarzycki
- Medical University of Gdańsk, II Clinic of Orthopaedics and Kinetic Organ Traumatology, Poland
| |
Collapse
|
26
|
Párraga Quiroga JM, Ito K, van Donkelaar CC. Meniscus replacement: Influence of geometrical mismatches on chondroprotective capabilities. J Biomech 2015; 48:1371-6. [PMID: 25835788 DOI: 10.1016/j.jbiomech.2015.02.063] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Accepted: 02/28/2015] [Indexed: 10/23/2022]
Abstract
The chondroprotective success of meniscal transplantation is variable. Poorly controlled factors such as a geometrical mismatch of the implant may be partly responsible. Clinical data, animal studies and cadaver experiments suggest that smaller transplants perform better than oversized, but clear evidence is lacking. The hypothesis of this study is that smaller menisci outperform larger ones because they distribute stresses more effectively at those particular locations that receive the highest loads. Consequently, collagen in the adjacent cartilage is protected from damage due to overstraining. Experimentally it is not possible to measure load distribution and collagen strain inside articular cartilage (AC). Therefore, a numerical model was used to determine the mechanical conditions throughout the depth of the AC. Meniscus implants with different sizes and mechanical properties were evaluated. These were compared with healthy and with meniscectomized joints. To account for the time-dependent behavior 600s of loading was simulated; results were visualized after 1s and 600s. Simulations showed that AC's strains strongly depended on implant size and loading duration. They depended less on the stiffness of the implant material. With an oversized implant, collagen strains were particularly large in the femoral AC initially and further increased upon sustained loading. The severest compressive strains occurred after sustained loading in the meniscectomized joint. Strains with an undersized meniscus were comparable to a perfectly sized implant. In conclusion, these results support the hypothesis that an undersized implant may outperform an oversized one because it distributes stresses better in the most intensely loaded joint area.
Collapse
Affiliation(s)
- J M Párraga Quiroga
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB Eindhoven, The Netherlands
| | - K Ito
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB Eindhoven, The Netherlands
| | - C C van Donkelaar
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600MB Eindhoven, The Netherlands.
| |
Collapse
|
27
|
Khoshgoftar M, Vrancken ACT, van Tienen TG, Buma P, Janssen D, Verdonschot N. The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant. J Biomech 2015; 48:1427-35. [PMID: 25766390 DOI: 10.1016/j.jbiomech.2015.02.034] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Accepted: 02/15/2015] [Indexed: 10/23/2022]
Abstract
Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial meniscus. However, this model did not provide information on the functional importance of these geometry characteristics. Therefore, in this study finite element simulations were performed to determine the influence of anatomically-based meniscal implant size and shape variations on knee cartilage contact pressures. Finite element simulations of the knee joint were performed for a total medial meniscectomy, an allograft, the average implant geometry, six implant sizes and ten shape variations. The geometries of the allograft and all implant variations were based on the meniscus SSM. Cartilage contact pressures and implant tensile strains were evaluated in full extension under 1200N of axial compression. The average implant induced cartilage peak pressures intermediate between the allograft and meniscectomy and also reduced the cartilage area subjected to pressures >5MPa compared to the meniscectomy. The smaller implant sizes resulted in lower cartilage peak pressures and compressive strains than the allograft, yet high implant tensile strains were observed. Shape modes 2, 3 and 6 affected the cartilage contact stresses but to a lesser extent than the size variations. Shape modes 4 and 5 did not result in changes of the cartilage stress levels. The present study indicates that cartilage contact mechanics are more sensitive to implant size than to implant shape. Down-sizing the implant resulted in more favorable contact mechanics, but caused excessive material strains. Further evaluations are necessary to balance cartilage contact pressures and material strains to ensure cartilage protection and longevity of the implant.
Collapse
Affiliation(s)
- M Khoshgoftar
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, The Netherlands
| | - A C T Vrancken
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, The Netherlands.
| | - T G van Tienen
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, The Netherlands
| | - P Buma
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Orthopaedic Research Lab, Nijmegen, The Netherlands
| | - D Janssen
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, The Netherlands
| | - N Verdonschot
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Lab, Nijmegen, The Netherlands; Laboratory for Biomechanical Engineering, University of Twente, Enschede, The Netherlands
| |
Collapse
|
28
|
Abstract
The meniscus plays a critical biomechanical role in the knee, providing load support, joint stability, and congruity. Importantly, growing evidence indicates that the mechanobiologic response of meniscal cells plays a critical role in the physiologic, pathologic, and repair responses of the meniscus. Here we review experimental and theoretical studies that have begun to directly measure the biomechanical effects of joint loading on the meniscus under physiologic and pathologic conditions, showing that the menisci are exposed to high contact stresses, resulting in a complex and nonuniform stress-strain environment within the tissue. By combining microscale measurements of the mechanical properties of meniscal cells and their pericellular and extracellular matrix regions, theoretical and experimental models indicate that the cells in the meniscus are exposed to a complex and inhomogeneous environment of stress, strain, fluid pressure, fluid flow, and a variety of physicochemical factors. Studies across a range of culture systems from isolated cells to tissues have revealed that the biological response of meniscal cells is directly influenced by physical factors, such as tension, compression, and hydrostatic pressure. In addition, these studies have provided new insights into the mechanotransduction mechanisms by which physical signals are converted into metabolic or pro/anti-inflammatory responses. Taken together, these in vivo and in vitro studies show that mechanical factors play an important role in the health, degeneration, and regeneration of the meniscus. A more thorough understanding of the mechanobiologic responses of the meniscus will hopefully lead to therapeutic approaches to prevent degeneration and enhance repair of the meniscus.
Collapse
|
29
|
Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures? Knee Surg Sports Traumatol Arthrosc 2015; 23:83-9. [PMID: 24841938 DOI: 10.1007/s00167-014-2966-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Accepted: 03/19/2014] [Indexed: 01/14/2023]
Abstract
PURPOSE Meniscal repair devices have been extensively tested during the past decades as reported in the literature. Reviewing the different meniscal repair devices and sutures with their respective biomechanical properties. METHODS For this meta-analysis, we conducted a systematic online search using PubMed, EMBASE, CCTR, and CINAHL using the search terms Meniscus OR Meniscal AND Biomechanics AND Repair). Load-to-failure (LtF), stiffness, and cyclic outcome measures were extracted independently and in duplicate. The systematic search revealed 841 manuscripts in total. After exclusion of duplicates and irrelevant publications, 41 studies remained for final analysis. The studies were published in English and German from 1995 to 2013. Due to differing cyclic force protocols, cyclic outcomes had to be excluded. RESULTS Overall, sutures had a higher LtF [suture: 87.7 ± 0.3 N (weighted mean ± standard error), device: 56.3 ± 0.1 N] and stiffness (suture: 8.9 ± 0.04 N/mm, device: 8.6 ± 0.04 N/mm) than devices, both p < 0.05. In LfT testing, PDS 0 Vertical (145.0 ± 8.1 N), OrthoCord 2-0 (143.6 ± 11.3 N), and Ethibond No 0 Vertical (133.4 ± 7.7 N) were the strongest sutures and Meniscal Viper (140.9 ± 5.1 N), MaxFire Vertical (136.2 ± 11.3 N), and FasT-Fix Vertical (115.2 ± 1.6 N) were the strongest devices. Second-generation devices were significantly stronger and stiffer than first-generation devices (p < 0.001). CLINICAL RELEVANCE Suture repair remains the gold standard with a vertically oriented suture configuration showing superior LtF values compared to a horizontal configuration. Nevertheless, some meniscal repair devices have similar biomechanical properties to suture repairs. Both suture repairs and devices have a place in meniscal restoration. LEVEL OF EVIDENCE None, meta-analysis of controlled laboratory studies.
Collapse
|
30
|
Leatherman ER, Guo H, Gilbert SL, Hutchinson ID, Maher SA, Santner TJ. Using a statistically calibrated biphasic finite element model of the human knee joint to identify robust designs for a meniscal substitute. J Biomech Eng 2014; 136:1865926. [PMID: 24770342 DOI: 10.1115/1.4027510] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Accepted: 04/28/2014] [Indexed: 11/08/2022]
Abstract
This paper describes a methodology for selecting a set of biomechanical engineering design variables to optimize the performance of an engineered meniscal substitute when implanted in a population of subjects whose characteristics can be specified stochastically. For the meniscal design problem where engineering variables include aspects of meniscal geometry and meniscal material properties, this method shows that meniscal designs having simultaneously large radial modulus and large circumferential modulus provide both low mean peak contact stress and small variability in peak contact stress when used in the specified subject population. The method also shows that the mean peak contact stress is relatively insensitive to meniscal permeability, so the permeability used in the manufacture of a meniscal substitute can be selected on the basis of manufacturing ease or cost. This is a multiple objective problem with the mean peak contact stress over the population of subjects and its variability both desired to be small. The problem is solved by using a predictor of the mean peak contact stress across the tibial plateau that was developed from experimentally measured peak contact stresses from two modalities. The first experimental modality provided computed peak contact stresses using a finite element computational simulator of the dynamic tibial contact stress during axial dynamic loading. A small number of meniscal designs with specified subject environmental inputs were selected to make computational runs and to provide training data for the predictor developed below. The second experimental modality consisted of measured peak contact stress from a set of cadaver knees. The cadaver measurements were used to bias-correct and calibrate the simulator output. Because the finite element simulator is expensive to evaluate, a rapidly computable (calibrated) Kriging predictor was used to explore extensively the contact stresses for a wide range of meniscal engineering inputs and subject variables. The predicted values were used to determine the Pareto optimal set of engineering inputs to minimize peak contact stresses in the targeted population of subjects.
Collapse
|
31
|
Freutel M, Schmidt H, Dürselen L, Ignatius A, Galbusera F. Finite element modeling of soft tissues: material models, tissue interaction and challenges. Clin Biomech (Bristol, Avon) 2014; 29:363-72. [PMID: 24529470 DOI: 10.1016/j.clinbiomech.2014.01.006] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2013] [Revised: 01/14/2014] [Accepted: 01/14/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND Musculoskeletal soft tissues, such as articular cartilage, ligaments, knee meniscus and intervertebral disk, have a complex structure, which provides elasticity and capability to support and distribute the body loads. Soft tissues describe an inhomogeneous and multiphasic structure, and exhibit a nonlinear, time-dependent behavior. Their mechanical response is governed by a substance composed of protein fiber-rich and proteoglycan-rich extracellular matrix and interstitial fluid. Protein fibers (e.g. collagen) give the tissue direction dependent stiffness and strength. To investigate these complex biological systems, the use of mathematical tools is well established, alone or in combination with experimental in vitro and in vivo tests. However, the development of these models poses many challenges due to the complex structure and mechanical response of soft tissues. METHODS Non-systematic literature review. FINDINGS This paper provides a summary of different modeling strategies with associated material properties, contact interactions between articulating tissues, validation and sensitivity of soft tissues with special focus on knee joint soft tissues and intervertebral disk. Furthermore, it reviews and discusses some salient clinical findings of reported finite element simulations. INTERPRETATION Model studies extensively contributed to the understanding of functional biomechanics of soft tissues. Models can be effectively used to elucidate clinically relevant questions. However, users should be aware of the complexity of such tissues and of the capabilities and limitations of these approaches to adequately simulate a specific in vivo or in vitro phenomenon.
Collapse
Affiliation(s)
- Maren Freutel
- Institute of Orthopaedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany.
| | - Hendrik Schmidt
- Julius Wolff Institut, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Lutz Dürselen
- Institute of Orthopaedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany
| | - Anita Ignatius
- Institute of Orthopaedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany
| | | |
Collapse
|
32
|
Sanchez-Adams J, Wilusz RE, Guilak F. Atomic force microscopy reveals regional variations in the micromechanical properties of the pericellular and extracellular matrices of the meniscus. J Orthop Res 2013; 31:1218-25. [PMID: 23568545 PMCID: PMC4037160 DOI: 10.1002/jor.22362] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Accepted: 03/07/2013] [Indexed: 02/04/2023]
Abstract
Regional variations in the composition and architecture of the extracellular matrix (ECM) and pericellular matrix (PCM) of the knee meniscus play important roles in determining the local mechanical environment of meniscus cells. In this study, atomic force microscopy was used to spatially map the mechanical properties of matched ECM and perlecan-labeled PCM sites within the outer, middle, and inner porcine medial meniscus, and to evaluate the properties of the proximal surface of each region. The elastic modulus of the PCM was significantly higher in the outer region (151.4 ± 38.2 kPa) than the inner region (27.5 ± 8.8 kPa), and ECM moduli were consistently higher than region-matched PCM sites in both the outer (320.8 ± 92.5 kPa) and inner (66.1 ± 31.4 kPa) regions. These differences were associated with a higher proportion of aligned collagen fibers and lower glycosaminoglycan content in the outer region. Regional variations in the elastic moduli and some viscoelastic properties were observed on the proximal surface of the meniscus, with the inner region exhibiting the highest moduli overall. These results indicate that matrix architecture and composition play an important role in the regional micromechanical properties of the meniscus, suggesting that the local stress-strain environment of meniscal cells may vary significantly among the different regions.
Collapse
Affiliation(s)
- Johannah Sanchez-Adams
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, United States
| | - Rebecca E. Wilusz
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, United States,Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Farshid Guilak
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, United States,Department of Biomedical Engineering, Duke University, Durham, NC, United States,Corresponding Author: 375 Medical Sciences Research Bldg., Box 3093 DUMC, Durham, NC 27710 Phone: 919-684-2521 Fax: 919-681-8490
| |
Collapse
|
33
|
Garcia-Martin E, Calvo B, Malvè M, Herrero R, Fuertes I, Ferreras A, Larrosa JM, Polo V, Pablo LE. Three-dimensional geometries representing the retinal nerve fiber layer in multiple sclerosis, optic neuritis, and healthy eyes. Ophthalmic Res 2013; 50:72-81. [PMID: 23774269 DOI: 10.1159/000350413] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2012] [Accepted: 01/24/2013] [Indexed: 11/19/2022]
Abstract
BACKGROUND To represent and interpret the three-dimensional (3D) geometry and the distribution of the axonal damage to the retinal nerve fiber layer (RNFL) in patients with multiple sclerosis (MS) compared with healthy subjects. To analyze alterations in RNFL morphology in eyes of MS patients with or without previous episodes of optic neuritis (ON). METHODS MS patients (n = 122) and age-matched healthy subjects (n = 108) were enrolled. The Spectralis optical coherence tomography system was used to determine the circumpapillary RNFL thickness. The 768 RNFL thickness measurements were used to evaluate thickness measurements in patients with or without antecedent ON and to design a 3D reconstruction of the RNFL thickness representing the mechanobiologic tissue response to neurodegeneration caused by MS and ON episodes. RESULTS RNFL thickness was decreased in MS patients, and was higher in the MS group with previous ON. Statistical analysis and 3D RNFL reconstruction revealed greater damage to the ganglionar cells in the superonasal RNFL area (101.77 µm in MS vs. 125.47 µm in healthy subjects) and in the inferotemporal RNFL (119.05 µm in MS eyes and 149.26 µm in healthy eyes). CONCLUSIONS The 3D representation of RNFL thickness based on measurements allows physicians to better observe damage in the temporal areas, especially in patients with previous ON.
Collapse
Affiliation(s)
- E Garcia-Martin
- Ophthalmology Department, Miguel Servet University Hospital, Zaragoza, Spain.
| | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Recent advances in computational mechanics of the human knee joint. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013; 2013:718423. [PMID: 23509602 PMCID: PMC3590578 DOI: 10.1155/2013/718423] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2012] [Revised: 11/21/2012] [Accepted: 12/20/2012] [Indexed: 11/18/2022]
Abstract
Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling.
Collapse
|
35
|
Dong Y, Hu G, Dong Y, Hu Y, Xu Q. The effect of meniscal tears and resultant partial meniscectomies on the knee contact stresses: a finite element analysis. Comput Methods Biomech Biomed Engin 2013; 17:1452-63. [DOI: 10.1080/10255842.2012.753063] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
36
|
Bedi A, Kelly N, Baad M, Fox AJS, Ma Y, Warren RF, Maher SA. Dynamic contact mechanics of radial tears of the lateral meniscus: implications for treatment. Arthroscopy 2012; 28:372-81. [PMID: 22074620 DOI: 10.1016/j.arthro.2011.08.287] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Revised: 08/03/2011] [Accepted: 08/03/2011] [Indexed: 02/02/2023]
Abstract
PURPOSE To characterize the effect of radial tears (RTs) of the lateral meniscus and their subsequent treatment (inside-out repair, partial meniscectomy) on joint contact mechanics during simulated gait. METHODS Six human cadaveric knees were mounted on a simulator programmed to mimic human gait. A sensor was inserted below the lateral meniscus to measure peak joint contact pressure location, magnitude, and contact area. The following conditions were compared: intact meniscus, 30% RT (at the popliteal hiatus), 60% RT, 90% RT, repair, and partial meniscectomy. Data were analyzed in the midstance phase of gait (14% and 45%) when axial force was at its highest (2,100 N). RESULTS Intact knees had peak contact pressures of 5.9 ± 0.9 MPa and 6.4 ± 1.1 MPa at 14% and 45% of gait, respectively. RTs of up to and including 60% had no effect on pressure magnitude or location. RTs of 90% resulted in significantly increased peak pressure (8.4 ± 1.1 MPa) in the postero-peripheral aspect of the tibial plateau and reduced contact area versus the intact knee, at 45% of gait. Repair resulted in a significant decrease in peak pressure (7.7 ± 1.0 MPa) relative to 90% RT but had no effect on contact area. Partial lateral meniscectomy resulted in areas and pressures that were not significantly different from 90% tears (8.7 ± 1.5 MPa). CONCLUSIONS Simulated large RTs of the lateral meniscus in the region of the popliteal hiatus show unfavorable dynamic contact mechanics that are not significantly different from those resulting from a partial lateral meniscectomy. Pressure was significantly reduced with inside-out repair but was not affected by partial meniscectomy; contact area was not restored to that of the intact condition for either procedure. CLINICAL RELEVANCE Large RTs in the region of the popliteal hiatus show unfavorable dynamic contact mechanics.
Collapse
Affiliation(s)
- Asheesh Bedi
- MedSport, University of Michigan, Ann Arbor, Michigan 48106, USA.
| | | | | | | | | | | | | |
Collapse
|
37
|
Matsubara H, Okazaki K, Izawa T, Tashiro Y, Matsuda S, Nishimura T, Nakanishi Y, Kawamura H, Iwamoto Y. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing. Am J Sports Med 2012; 40:414-8. [PMID: 22016457 DOI: 10.1177/0363546511424395] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Repair of complete radial meniscal tears is a key to restoring the mechanical integrity necessary to maintain hoop tension in the meniscus. The primary stability of the meniscal repair is one of the most important factors for meniscal healing, but the biomechanical structural properties of different repair techniques for complete radial meniscal tears remain unknown. HYPOTHESIS Our novel cross-suture technique with suturing oblique to the collagen fibrils of the meniscus will yield better fixation than the standard double horizontal suture technique with suturing parallel to the collagen fibrils in the meniscus. STUDY DESIGN Controlled laboratory study. METHODS Biomechanical investigation was performed on 40 fresh human menisci (2 groups of 20 menisci each) from patients who underwent total knee arthroplasty. In the cross-suture technique group (group A), the sutures crossed over 5 mm from the tear and 5 mm and 10 mm from the rim. In the double horizontal suture technique group (group B), the sutures were parallel and had the same attachment points as group A. The specimens were cyclically loaded 500 times between 5 and 30 N and then loaded to failure after completion of the cyclic load testing. RESULTS Compared with the double horizontal suture group, the cross-suture group had a significantly higher ultimate failure load (78.96 ± 19.27 N vs 68.16 ± 12.92 N; P < .05), significantly greater stiffness (8.01 ± 1.54 N/mm vs 6.46 ± 1.12 N/mm; P < .05), and significantly lower displacement (5.74 ± 1.84 mm vs 8.56 ± 2.39 mm; P < .05) after a 500-cycle loading protocol. CONCLUSION Our cross-suture technique significantly improved the structural properties of the repaired complete radial meniscal tears. CLINICAL RELEVANCE The cross-suture technique for repair of radial meniscal tears provides high stability and could be a promising solution in young and in active patients.
Collapse
Affiliation(s)
- Hirokazu Matsubara
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Oni DB, Jeyapalan K, Oni OOA. An observational study on MR images of the effect of the discoid meniscus on articular cartilage thickness. Knee 2011; 18:202-4. [PMID: 20542700 DOI: 10.1016/j.knee.2010.05.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2009] [Revised: 05/06/2010] [Accepted: 05/07/2010] [Indexed: 02/02/2023]
Abstract
The discoid meniscus is known to affect the morphology and mechanics of the knee compartment in which it is housed. To determine whether it also is determinative of the articular cartilage thickness, measurements were made on MR images. There was no statistically significant difference in femoral or tibial articular cartilage thickness between compartments with normal meniscus and compartments with discoid meniscus. These findings suggest that mechanical disturbances wrought by the discoid shape do not have a 'Wolff law' effect.
Collapse
|
39
|
Ballyns JJ, Cohen DL, Malone E, Maher SA, Potter HG, Wright T, Lipson H, Bonassar LJ. An optical method for evaluation of geometric fidelity for anatomically shaped tissue-engineered constructs. Tissue Eng Part C Methods 2010; 16:693-703. [PMID: 19788346 DOI: 10.1089/ten.tec.2009.0441] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Quantification of shape fidelity of complex geometries for tissue-engineered constructs has not been thoroughly investigated. The objective of this study was to quantitatively describe geometric fidelities of various approaches to the fabrication of anatomically shaped meniscal constructs. Ovine menisci (n = 4) were imaged using magnetic resonance imaging (MRI) and microcomputed tomography (microCT). Acrylonitrile butadiene styrene plastic molds were designed from each imaging modality and three-dimensional printed on a Stratasys FDM 3000. Silastic impression molds were fabricated directly from ovine menisci. These molds were used to generate shaped constructs using 2% alginate with 2% CaSO(4). Solid freeform fabrication was conducted on a custom open-architecture three-dimensional printing platform. Printed samples were made using 2% alginate with 0.75% CaSO(4). Hydrogel constructs were scanned via laser triangulation distance sensor. The point cloud images were analyzed to acquire computational measurements for key points of interest (e.g., height, width, and volume). Silastic molds were within + or - 10% error with respect to the native tissue for seven key measurements, microCT molds for six of seven, microCT prints for four of seven, MRI molds for five of seven, and MRI prints for four of seven. This work shows the ability to generate and quantify anatomically shaped meniscal constructs of high geometric fidelity and lends insight into the relative geometric fidelities of several tissue engineering techniques.
Collapse
Affiliation(s)
- Jeffrey J Ballyns
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Ali N, Rouhi G. Barriers to predicting the mechanisms and risk factors of non-contact anterior cruciate ligament injury. Open Biomed Eng J 2010; 4:178-89. [PMID: 21625370 PMCID: PMC3102313 DOI: 10.2174/1874120701004010178] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2010] [Revised: 07/23/2010] [Accepted: 07/25/2010] [Indexed: 01/12/2023] Open
Abstract
High incidences of non-contact anterior cruciate ligament (ACL) injury, frequent requirements for ACL reconstruction, and limited understanding of ACL mechanics have engendered considerable interest in quantifying the ACL loading mechanisms. Although some progress has been made to better understand non-contact ACL injuries, information on how and why non-contact ACL injuries occur is still largely unavailable. In other words, research is yet to yield consensus on injury mechanisms and risk factors. Biomechanics, video analysis, and related study approaches have elucidated to some extent how ACL injuries occur. However, these approaches are limited because they provide estimates, rather than precise measurements of knee - and more specifically ACL - kinematics at the time of injury. These study approaches are also limited in their inability to simultaneously capture many of the contributing factors to injury.This paper aims at elucidating and summarizing the key challenges that confound our understanding in predicting the mechanisms and subsequently identifying risk factors of non-contact ACL injury. This work also appraise the methodological rigor of existing study approaches, review testing protocols employed in published studies, as well as presents a possible coupled approach to better understand injury mechanisms and risk factors of non-contact ACL injury. Three comprehensive electronic databases and hand search of journal papers, covering numerous full text published English articles were utilized to find studies on the association between ACL and injury mechanisms, ACL and risk factors, as well as, ACL and investigative approaches. This review unveils that new research modalities and/or coupled research methods are required to better understand how and why the ACL gets injured. Only by achieving a better understanding of ACL loading mechanisms and the associated contributing factors, one will be able to develop robust prevention strategies and exercise regimens to mitigate non-contact ACL injuries.
Collapse
Affiliation(s)
- Nicholas Ali
- School of Human Kinetics, University of Ottawa, Ottawa, Canada
| | | |
Collapse
|
41
|
Elsner JJ, Portnoy S, Zur G, Guilak F, Shterling A, Linder-Ganz E. Design of a Free-Floating Polycarbonate-Urethane Meniscal Implant Using Finite Element Modeling and Experimental Validation. J Biomech Eng 2010; 132:095001. [DOI: 10.1115/1.4001892] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The development of a synthetic meniscal implant that does not require surgical attachment but still provides the biomechanical function necessary for joint preservation would have important advantages. We present a computational-experimental approach for the design optimization of a free-floating polycarbonate-urethane (PCU) meniscal implant. Validated 3D finite element (FE) models of the knee and PCU-based implant were analyzed under physiological loads. The model was validated by comparing calculated pressures, determined from FE analysis to tibial plateau contact pressures measured in a cadaveric knee in vitro. Several models of the implant, some including embedded reinforcement fibers, were tested. An optimal implant configuration was then selected based on the ability to restore pressure distribution in the knee, manufacturability, and long-term safety. The optimal implant design entailed a PCU meniscus embedded with circumferential reinforcement made of polyethylene fibers. This selected design can be manufactured in various sizes, without risking its integrity under joint loads. Importantly, it produces an optimal pressure distribution, similar in shape and values to that of natural meniscus. We have shown that a fiber-reinforced, free-floating PCU meniscal implant can redistribute joint loads in a similar pattern to natural meniscus, without risking the integrity of the implant materials.
Collapse
Affiliation(s)
- Jonathan J. Elsner
- Research and Development Center, Active Implants Corporation, Netanya 42505, Israel
| | - Sigal Portnoy
- Research and Development Center, Active Implants Corporation, Netanya 42505, Israel
| | - Gal Zur
- Research and Development Center, Active Implants Corporation, Netanya 42505, Israel
| | | | - Avi Shterling
- Research and Development Center, Active Implants Corporation, Netanya 42505, Israel
| | - Eran Linder-Ganz
- Research and Development Center, Active Implants Corporation, Netanya 42505, Israel
| |
Collapse
|
42
|
Ballyns JJ, Wright TM, Bonassar LJ. Effect of media mixing on ECM assembly and mechanical properties of anatomically-shaped tissue engineered meniscus. Biomaterials 2010; 31:6756-63. [PMID: 20541796 DOI: 10.1016/j.biomaterials.2010.05.039] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2010] [Accepted: 05/18/2010] [Indexed: 11/19/2022]
Abstract
This study investigated the hypothesis that controlled media mixing will enhance tissue formation and increase mechanical properties of anatomically-shaped tissue engineered menisci. Bovine meniscal fibrochondrocytes were seeded in 2% w/v alginate, cross-linked with 0.02 g/mL CaSO(4), and injected into molds of menisci. Engineered menisci were incubated for up to 6 weeks. A mixing media bioreactor was designed to ensure proper mixing of culture medium while protecting constructs from the spinning impeller. Impeller speeds were calibrated to produce Reynolds number (Re) of 0.5, 2.9, 5.8, 10.2, and 21.8. Constructs were divided a tested in confined compression and in tension to determine the equilibrium and tensile moduli, respectively. Media stimulation resulted in a 2-5 fold increase in mechanical properties and a 2-3 fold increase in matrix accumulation in constructs over 6 weeks in culture. Benefits from mixing stimulation for collagen accumulation and compressive modulus appeared to peak near Re 2.9, and decreased with increased mixing intensity. This study suggests that fluid mixing can be optimized to enhance mechanical properties of anatomically-shaped engineered constructs.
Collapse
Affiliation(s)
- Jeffrey J Ballyns
- Cornell University, Biomedical Engineering, Weill Hall, Ithaca, NY 14853, USA
| | | | | |
Collapse
|
43
|
Bedi A, Kelly NH, Baad M, Fox AJS, Brophy RH, Warren RF, Maher SA. Dynamic contact mechanics of the medial meniscus as a function of radial tear, repair, and partial meniscectomy. J Bone Joint Surg Am 2010; 92:1398-408. [PMID: 20516315 DOI: 10.2106/jbjs.i.00539] [Citation(s) in RCA: 208] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The menisci are integral to normal knee function. The purpose of this study was to measure the contact pressures transmitted to the medial tibial plateau under physiological loads as a function of the percentage of the meniscus involved by the radial tear or repair. Our hypotheses were that (1) there is a threshold size of radial tears above which contact mechanics are adversely affected, and (2) partial meniscectomy results in increased contact pressure compared with that found after meniscal repair. METHODS A knee simulator was used to apply physiological multidirectional dynamic gait loads across human cadaver knees. A sensor inserted below the medial meniscus recorded contact pressures in association with (1) an intact meniscus, (2) a radial tear involving 30% of the meniscal rim width, (3) a radial tear involving 60% of the width, (4) a radial tear involving 90% of the width, (5) an inside-out repair with horizontal mattress sutures, and (6) a partial meniscectomy. The effects of these different types of meniscal manipulation on the magnitude and location of the peak contact pressure were assessed at 14% and 45% of the gait cycle. RESULTS The peak tibial contact pressure in the intact knees was 6 +/- 0.5 MPa and 7.4 +/- 0.6 MPa at 14% and 45% of the gait cycle, respectively. The magnitude and location of the peak contact pressure were not affected by radial tears involving up to 60% of the meniscal rim width. Radial tears involving 90% resulted in a posterocentral shift in peak-pressure location manifested by an increase in pressure in that quadrant of 1.3 +/- 0.5 MPa at 14% of the gait cycle relative to the intact condition. Inside-out mattress suture repair of a 90% tear did not restore the location of the pressure peak to that of the intact knee. Partial meniscectomy led to a further increase in contact pressure in the posterocentral quadrant of 1.4 +/- 0.7 MPa at 14% of the gait cycle. CONCLUSIONS Large radial tears of the medial meniscus are not functionally equivalent to meniscectomies; the residual meniscus continues to provide some load transmission and distribution functions across the joint.
Collapse
Affiliation(s)
- Asheesh Bedi
- Sports Medicine and Shoulder Service, The Hospital for Special Surgery, New York, NY 10021, USA
| | | | | | | | | | | | | |
Collapse
|
44
|
Gunja NJ, Huey DJ, James RA, Athanasiou KA. Effects of agarose mould compliance and surface roughness on self-assembled meniscus-shaped constructs. J Tissue Eng Regen Med 2010; 3:521-30. [PMID: 19658151 DOI: 10.1002/term.191] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The meniscus is a fibrocartilaginous tissue that is critically important to the loading patterns within the knee joint. If the meniscus structure is compromised, there is little chance of healing, due to limited vascularity in the inner portions of the tissue. Several tissue-engineering techniques to mimic the complex geometry of the meniscus have been employed. Of these, a self-assembly, scaffoldless approach employing agarose moulds avoids drawbacks associated with scaffold use, while still allowing the formation of robust tissue. In this experiment two factors were examined, agarose percentage and mould surface roughness, in an effort to consistently obtain constructs with adequate geometric properties. Co-cultures of ACs and MCs (50:50 ratio) were cultured in smooth or rough moulds composed of 1% or 2% agarose for 4 weeks. Morphological results showed that constructs formed in 1% agarose moulds, particularly smooth moulds, were able to maintain their shape over the 4 week culture period. Significant increases were observed for the collagen II:collagen I ratio, total collagen, GAG and tensile and compressive properties in smooth wells. Cell number per construct was higher in the rough wells. Overall, it was observed that the topology of an agarose surface may be able to affect the phenotypic properties of cells that are on that surface, with smooth surfaces supporting a more chondrocytic phenotype. In addition, wells made from 1% agarose were able to prevent construct buckling potentially, due to their higher compliance.
Collapse
Affiliation(s)
- Najmuddin J Gunja
- Department of Bioengineering, Rice University, Houston, TX 77251, USA
| | | | | | | |
Collapse
|
45
|
Sigal IA, Whyne CM. Mesh morphing and response surface analysis: quantifying sensitivity of vertebral mechanical behavior. Ann Biomed Eng 2009; 38:41-56. [PMID: 19859809 DOI: 10.1007/s10439-009-9821-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2009] [Accepted: 10/10/2009] [Indexed: 10/20/2022]
Abstract
Vertebrae provide essential biomechanical stability to the skeleton. In this work novel morphing techniques were used to parameterize three aspects of the geometry of a specimen-specific finite element (FE) model of a rat caudal vertebra (process size, neck size, and end-plate offset). Material properties and loading were also parameterized using standard techniques. These parameterizations were then integrated within an RSM framework and used to produce a family of FE models. The mechanical behavior of each model was characterized by predictions of stress and strain. A metamodel was fit to each of the responses to yield the relative influences of the factors and their interactions. The direction of loading, offset, and neck size had the largest influences on the levels of vertebral stress and strain. Material type was influential on the strains, but not the stress. Process size was substantially less influential. A strong interaction was identified between dorsal-ventral offset and dorsal-ventral off-axis loading. The demonstrated approach has several advantages for spinal biomechanical analysis by enabling the examination of the sensitivity of a specimen to multiple variations in shape, and of the interactions between shape, material properties, and loading.
Collapse
Affiliation(s)
- Ian A Sigal
- Orthopaedic Biomechanics Laboratory, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, UB19, Toronto, ON, M4N 3M5, Canada.
| | | |
Collapse
|
46
|
Bursac P, York A, Kuznia P, Brown LM, Arnoczky SP. Influence of donor age on the biomechanical and biochemical properties of human meniscal allografts. Am J Sports Med 2009; 37:884-9. [PMID: 19336615 DOI: 10.1177/0363546508330140] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Although the use of meniscal allografts to replace severely damaged or absent menisci is commonplace, little is known about the effects of donor age on the biochemical and biomechanical properties of human menisci. HYPOTHESIS The mechanical and biochemical properties of human medial and lateral menisci from donors less than 45 years of age do not vary with donor age. STUDY DESIGN Controlled laboratory study. METHODS Thirty-three lateral and 25 medial menisci from 34 donors (26 male and 8 female) ranging from 15 to 44 years of age were harvested and immediately stored at -80 degrees C. The outer third of each meniscus was subjected to static and dynamic tensile analysis. In addition, the biochemical composition (collagen, proteoglycan, and water content) of these samples was analyzed. RESULTS There was no correlation between donor age and static tensile stiffness for either the lateral (R(2) = .003) or medial (R(2) = .002) meniscus. Likewise, there was no correlation between donor age and dynamic tensile modulus for either the lateral or medial meniscus. Although there was a weak, positive correlation between water content and age in both lateral (R(2) = .22) and medial (R(2) = .25) menisci, there was no effect of age on collagen or proteoglycan content. There were no differences (P > .05) between female and male menisci in any of the measured biomechanical or biochemical parameters tested. CONCLUSION The tensile properties, as well as the collagen and proteoglycan content, of menisci from donors less than 45 years of age were not age dependent. CLINICAL RELEVANCE The age of the donor does not appear to affect the initial tensile properties of menisci from donors less than 45 years of age.
Collapse
Affiliation(s)
- Predrag Bursac
- Sports Medicine Group, RTI-Biologics, Inc., 11621 Research Circle, Alachua, FL 32615, USA.
| | | | | | | | | |
Collapse
|
47
|
López G, Maestro A, Llopis J, Leyes M, Forriol F. Implante meniscal de colágeno asociado a rotura del ligamento cruzado anterior. Rev Esp Cir Ortop Traumatol (Engl Ed) 2009. [DOI: 10.1016/j.recot.2008.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
48
|
López G, Maestro A, Llopis J, Leyes M, Forriol F. Collagen meniscal implants with an associated tear of the anterior cruciate ligament. Rev Esp Cir Ortop Traumatol (Engl Ed) 2009. [DOI: 10.1016/s1988-8856(09)70136-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
49
|
Isaksson H, van Donkelaar CC, Huiskes R, Yao J, Ito K. Determining the most important cellular characteristics for fracture healing using design of experiments methods. J Theor Biol 2008; 255:26-39. [PMID: 18723028 DOI: 10.1016/j.jtbi.2008.07.037] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2007] [Revised: 07/02/2008] [Accepted: 07/25/2008] [Indexed: 11/18/2022]
Abstract
Computational models are employed as tools to investigate possible mechanoregulation pathways for tissue differentiation and bone healing. However, current models do not account for the uncertainty in input parameters, and often include assumptions about parameter values that are not yet established. The objective of this study was to determine the most important cellular characteristics of a mechanoregulatory model describing both cell phenotype-specific and mechanobiological processes that are active during bone healing using a statistical approach. The computational model included an adaptive two-dimensional finite element model of a fractured long bone. Three different outcome criteria were quantified: (1) ability to predict sequential healing events, (2) amount of bone formation at early, mid and late stages of healing and (3) the total time until complete healing. For the statistical analysis, first a resolution IV fractional factorial design (L(64)) was used to identify the most significant factors. Thereafter, a three-level Taguchi orthogonal array (L(27)) was employed to study the curvature (non-linearity) of the 10 identified most important parameters. The results show that the ability of the model to predict the sequences of normal fracture healing was predominantly influenced by the rate of matrix production of bone, followed by cartilage degradation (replacement). The amount of bone formation at early stages was solely dependent on matrix production of bone and the proliferation rate of osteoblasts. However, the amount of bone formation at mid and late phases had the rate of matrix production of cartilage as the most influential parameter. The time to complete healing was primarily dependent on the rate of cartilage degradation during endochondral ossification, followed by the rate of cartilage formation. The analyses of the curvature revealed a linear response for parameters related to bone, where higher rates of formation were more beneficial to healing. In contrast, parameters related to fibrous tissue and cartilage showed optimum levels. Some fibrous connective tissue- and cartilage formation was beneficial to bone healing, but too much of either tissue delayed bone formation. The identified significant parameters and processes are further confirmed by in vivo animal experiments in the literature. This study illustrates the potential of design of experiments methods for evaluating computational mechanobiological model parameters and suggests that further experiments should preferably focus at establishing values of parameters related to cartilage formation and degradation.
Collapse
Affiliation(s)
- Hanna Isaksson
- AO Research Institute, AO Foundation, Clavadelerstrasse 8, 7270 Davos, Switzerland.
| | | | | | | | | |
Collapse
|
50
|
Cottrell JM, Scholten P, Wanich T, Warren RF, Wright TM, Maher SA. A new technique to measure the dynamic contact pressures on the Tibial Plateau. J Biomech 2008; 41:2324-9. [DOI: 10.1016/j.jbiomech.2008.04.024] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2007] [Revised: 03/19/2008] [Accepted: 04/14/2008] [Indexed: 12/01/2022]
|