1
|
Ozawa S, Ozawa-Morriello J, Rock R, Sromoski M, Walbolt S, Hall T, Pearse BL. Patient Blood Management as an Emerging Concept in Quality: The Role of Nurses. J Nurs Care Qual 2024; 39:129-135. [PMID: 37350618 DOI: 10.1097/ncq.0000000000000734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
BACKGROUND Transfusion of blood components has long been considered lifesaving therapy. While blood transfusion may be clinically indicated as a treatment option for some patients, the benefits of transfusion in asymptomatic, hemodynamically stable patients are questionable. PROBLEM Blood component transfusion is routinely used as a default therapy when not clinically indicated, increasing the risk of poor patient outcomes, adverse events, pressures on blood supply and availability, and increased health care costs. APPROACH Nurses have the responsibility to advocate for patients and reduce/avoid unnecessary blood transfusion through the implementation of patient blood management (PBM). The PBM paradigm includes treatment of anemia, minimizing blood loss and bleeding, optimization of coagulation, and employing true patient-centered decision making. CONCLUSIONS PBM should become the standard of care with the goal of improving health care quality and patient outcomes while using the multidisciplinary team for its implementation. As advocates for their patients, nurses can play a major role in the development, implementation, and promotion of PBM.
Collapse
Affiliation(s)
- Sherri Ozawa
- Author Affiliations: Deparment of Patient Blood Management (Mss Ozawa and Hall), Accumen Incorporated, Phoenix, Arizona; Department of Clinical Training and Evaluation Center, The University of Western Australia, Perth, Western Australia (Ms Ozawa); Department of Bloodless Medicine and Patient Blood Management, Englewood Health, Englewood, New Jersey (Ms Ozawa and Mr Ozawa-Morriello); Society for the Advancement of Patient Blood Management (SABM), Mt Royal, New Jersey (Ms Ozawa, Rock, Sromoski, Walbolt, and Hall and Mr Ozawa-Morriello); Department of Patient Blood Management and Center for Bloodless Medicine, Geisinger Health System, Danville, Pennsylvania (Mr Ozawa-Morriello and Ms Sromoski); Departments of Bloodless Medicine and Surgery, and Cardiac Surgery Services, Hackensack University Medical Center, Hackensack, New Jersey (Mr Ozawa-Morriello); Department of Patient Blood Management, Alberta Health Services, Calgary, Alberta, Canada (Ms Rock); Association for the Advancement of Blood & Biotherapies (AABB), Bethesda, Maryland (Ms Sromoski); ProMedica Health System, Toledo, Ohio (Ms Walbolt); Department of Patient Blood Management The Prince Charles Hospital, Brisbane, Queensland, Australia (Dr Pearse); and Department of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia (Dr Pearse)
| | | | | | | | | | | | | |
Collapse
|
2
|
Malik M, Al-Ghafry M, Haimed A, Su J, Lema M, Shore-Lessersson L, Acharya SS. Exploration of rotational thromboelastometry (ROTEM) to characterize the coagulation profiles of newly diagnosed pediatric leukemia patients. Thromb Res 2024; 233:109-118. [PMID: 38039723 DOI: 10.1016/j.thromres.2023.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/18/2023] [Accepted: 11/15/2023] [Indexed: 12/03/2023]
Abstract
BACKGROUND Viscoelastic testing has been used in adult hematologic malignancies in conjunction with conventional coagulation tests (CCTs) to predict coagulopathies and tailor blood product replacement. However, there is a paucity of similar pediatric studies. OBJECTIVES Analyze and correlate leukemia-associated coagulopathy in newly diagnosed pediatric leukemia patients using CCT's and Rotational Thromboelastometry (ROTEM). METHODS Pediatric patients with newly diagnosed acute leukemia underwent testing with ROTEM and CCTs on days 0, 15 and 29 of induction chemotherapy. RESULTS Sixty-two patients were enrolled. At presentation, 54.8 % of patients had platelets <50 K/μL, 73 % had prolonged PT, 1.6 % had fibrinogen <150 mg/dL. Fifteen patients (24.2 %) had WHO grade 1 bleeding and two patients (3 %) had WHO grade 4 bleeding. EXTEM/INTEM values at presentation (day 0) reflected hypocoagulability, however FIBTEM revealed hypercoagulability. Patients showed a progressive hypocoagulability in all ROTEM assays by day 15 (day 0 vs day 15, p < 0.001), with improvement by day 29 (day 15 vs day 29, p < 0.001). Day 0 ROTEM parameters were comparable to day 29. Fibrinogen strongly correlated with ROTEM at all three time points (p < 0.0001), along with platelet count with moderate correlations (p < 0.001). CONCLUSION Fibrinogen and platelets appear to be the drivers of leukemia associated coagulopathy in the pediatric population, suggesting the utility of using CCTs and ROTEM in this population to better evaluate hemostatic function and guide blood product replacement.
Collapse
Affiliation(s)
- Marium Malik
- Division of Pediatric Hematology, Oncology and Stem Cell Transplant - Cohen Children's Medical Center, New Hyde Park, New York, United States of America; Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America
| | - Maha Al-Ghafry
- Division of Pediatric Hematology, Oncology and Stem Cell Transplant - Cohen Children's Medical Center, New Hyde Park, New York, United States of America; Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America
| | - Abraham Haimed
- Department of Pediatrics - Cohen Children's Medical Center, New Hyde Park, New York, United States of America; Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America
| | - Julia Su
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America
| | - Maribel Lema
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America
| | - Linda Shore-Lessersson
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America; Division of Anesthesiology, North Shore University Hospital, Manhasset, New York, United States of America
| | - Suchitra S Acharya
- Division of Pediatric Hematology, Oncology and Stem Cell Transplant - Cohen Children's Medical Center, New Hyde Park, New York, United States of America; Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York, United States of America.
| |
Collapse
|
3
|
Qin D, Cai H, Liu Q, Lu T, Tang Z, Shang Y, Cui Y, Wang R. Nomogram model combined thrombelastography for venous thromboembolism risk in patients undergoing lung cancer surgery. Front Physiol 2023; 14:1242132. [PMID: 38162832 PMCID: PMC10757630 DOI: 10.3389/fphys.2023.1242132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 12/01/2023] [Indexed: 01/03/2024] Open
Abstract
Background: The aim of this study was to develop a nomogram model in combination with thromboelastography (TEG) to predict the development of venous thromboembolism (VTE) after lung cancer surgery. Methods: The data of 502 patients who underwent surgical treatment for lung cancer from December 2020 to December 2022 were retrospectively analyzed. Patients were then randomized into training and validation groups. Univariate and multivariate logistic regression analyses were carried out in the training group and independent risk factors were included in the nomogram to construct risk prediction models. The predictive capability of the model was assessed by the consistency index (C-index), receiver operating characteristic curves (ROC), the calibration plot and decision curve analysis (DCA). Results: The nomogram risk prediction model comprised of the following five independent risk factors: age, operation time, forced expiratory volume in one second and postoperative TEG parameters k value(K) and reaction time(R). The nomogram model demonstrated better predictive power than the modified Caprini model, with the C-index being greater. The calibration curve verified the consistency of nomogram between the two groups. Furthermore, DCA demonstrated the clinical value and potential for practical application of the nomogram. Conclusion: This study is the first to combine TEG and clinical risk factors to construct a nomogram to predict the occurrence of VTE in patients after lung cancer surgery. This model provides a simple and user-friendly method to assess the probability of VTE in postoperative lung cancer patients, enabling clinicians to develop individualized preventive anticoagulation strategies to reduce the incidence of such complications.
Collapse
Affiliation(s)
- Da Qin
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
- Organ Transplantation Center, The First Hospital of Jilin University, Changchun, China
| | - Hongfei Cai
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
| | - Qing Liu
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
| | - Tianyu Lu
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
| | - Ze Tang
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
| | - Yuhang Shang
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
| | - Youbin Cui
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
- Organ Transplantation Center, The First Hospital of Jilin University, Changchun, China
| | - Rui Wang
- Department of Thoracic Surgery, The First Hospital of Jilin University, Changchun, China
- Organ Transplantation Center, The First Hospital of Jilin University, Changchun, China
| |
Collapse
|
4
|
Ramanujam V, DiMaria S, Varma V. Thromboelastography in the Perioperative Period: A Literature Review. Cureus 2023; 15:e39407. [PMID: 37362492 PMCID: PMC10287184 DOI: 10.7759/cureus.39407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/23/2023] [Indexed: 06/28/2023] Open
Abstract
Assessing coagulation status is essential for prompt intervention to reduce morbidity and mortality related to bleeding and thrombotic complications during the perioperative period. Traditional coagulation tests such as platelet count, activated partial thromboplastin time (aPTT), prothrombin time (PT), international normalized ratio (INR), and activated clotting time (ACT) provide only static evaluation. These tests are not designed for assessment of dynamically changing coagulation conditions during the perioperative time. However, viscoelastic coagulation testing such as thromboelastography (TEG) produces a rapid numerical and graphical representation that helps to detect and direct targeted hemostatic therapy. Searching the literature through PubMed, Medline, Ovid, CINAHL, and ClinicalTrials.gov we retrieved 210 studies, which represent the use of TEG in the perioperative period. The included studies were categorized under various settings such as trauma, obstetrics, orthopedics, intensive care unit (ICU), cardiovascular, transplant, and miscellaneous scenarios. TEG showed promising results in trauma surgeries in predicting mortality, hypercoagulability, and bleeding even when it was compared to conventional methods. TEG was also useful in monitoring anticoagulant therapy in orthopedic and obstetric surgeries; however, its role in predicting thrombotic events, hypercoagulability, or complications was questionable. In ICU patients, it showed promising results, especially in the prediction or improvement of sepsis, coagulopathy, thrombotic events, ICU duration, hospital stay, and ventilator duration. TEG parameters effectively predicted hypercoagulation in transplant surgeries. Regarding cardiovascular surgeries, they were effective in the prediction of the need for blood products, coagulopathy, thrombotic events, and monitoring anticoagulation therapy. More randomized clinical trials comparing TEG parameters with standardized tools are needed to produce robust results to standardize its use in different perioperative settings.
Collapse
Affiliation(s)
- Vendhan Ramanujam
- Department of Anesthesiology, Rhode Island Hospital/The Warren Alpert Medical School of Brown University, Providence, USA
| | - Stephen DiMaria
- Department of Anesthesiology, Rhode Island Hospital/The Warren Alpert Medical School of Brown University, Providence, USA
| | - Vivek Varma
- Department of Anesthesiology, Rhode Island Hospital/The Warren Alpert Medical School of Brown University, Providence, USA
| |
Collapse
|
5
|
Viscoelastic Hemostatic Assays: A Primer on Legacy and New Generation Devices. J Clin Med 2022; 11:jcm11030860. [PMID: 35160311 PMCID: PMC8836477 DOI: 10.3390/jcm11030860] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 01/28/2022] [Accepted: 02/02/2022] [Indexed: 02/06/2023] Open
Abstract
Viscoelastic hemostatic assay (VHAs) are whole blood point-of-care tests that have become an essential method for assaying hemostatic competence in liver transplantation, cardiac surgery, and most recently, trauma surgery involving hemorrhagic shock. It has taken more than three-quarters of a century of research and clinical application for this technology to become mainstream in these three clinical areas. Within the last decade, the cup and pin legacy devices, such as thromboelastography (TEG® 5000) and rotational thromboelastometry (ROTEM® delta), have been supplanted not only by cartridge systems (TEG® 6S and ROTEM® sigma), but also by more portable point-of-care bedside testing iterations of these legacy devices (e.g., Sonoclot®, Quantra®, and ClotPro®). Here, the legacy and new generation VHAs are compared on the basis of their unique hemostatic parameters that define contributions of coagulation factors, fibrinogen/fibrin, platelets, and clot lysis as related to the lifespan of a clot. In conclusion, we offer a brief discussion on the meteoric adoption of VHAs across the medical and surgical specialties to address COVID-19-associated coagulopathy.
Collapse
|
6
|
Rodríguez-Martín I, Sánchez-Mora C, Fernández-López AR, González-Fernández FJ, Téllez-Cantero JC, Blanco-Marquez V, García de la Borbolla M, Santos-Jiménez JC, González-Rodríguez C, Garnacho-Montero J, Sánchez-Margalet V. Evaluation of health outcomes after the implementation of rotational thromboelastometry in patients undergoing cardiac surgery. Scandinavian Journal of Clinical and Laboratory Investigation 2022; 82:143-149. [PMID: 35112642 DOI: 10.1080/00365513.2022.2034038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Viscoelastic tests (rotational thromboelastometry, ROTEM®), together with the implementation of a specific algorithm for coagulation management in cardiac surgery, enable perioperative coagulopathy to be better controlled. METHODS Retrospective cohort study including 675 patients who underwent cardiac surgery with cardiopulmonary bypass. The incidence of allogeneic blood transfusions and clinical postoperative complications were analyzed before and after ROTEM® implementation. RESULTS Following viscoelastic testing and the implementation of a specific algorithm for coagulation management, the incidence of any allogeneic blood transfusion decreased (41.4% vs 31.9%, p = .026) during the perioperative period. In the group monitored with ROTEM®, decreased incidence of transfusion was observed for packed red blood cells (31.3% vs 19.8%, p = .002), fresh frozen plasma (9.8% vs 3.8%, p = .008), prothrombin complex concentrate administration (0.9% vs 0.3%, p = .599) and activated recombinant factor VII (0.3% vs 0.0%, p = .603). Increased incidence was observed for platelet transfusion (4.8% vs 6.8%, p = .530) and fibrinogen concentrate (0.9% vs 3.5%, p = .066), tranexamic acid (0.0% vs 0.6%, p = .370) and protamine administration (0.6% vs 0.9%, p = .908). Similar results were observed in the postoperative period, but with a decreased incidence of platelet transfusion (4.8% vs 3.8%, p = .813). In addition, statistically significant reductions were detected in the incidence of postoperative bleeding (9.5% vs 5.3%, p = .037), surgical reexploration (6.0% vs 2.9%, p = .035), and length of Intensive Care Unit (ICU) stay (6.0 days vs 5.3 days, p = .026). CONCLUSIONS The monitoring of hemostasis by ROTEM® in cardiac surgery, was associated with decreased incidence of allogeneic blood transfusion, clinical hematologic postoperative complications and lengths of ICU stay.
Collapse
Affiliation(s)
- Isabel Rodríguez-Martín
- Clinical Biochemistry Department, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| | - Catalina Sánchez-Mora
- Clinical Biochemistry Department, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| | | | | | - Juan Carlos Téllez-Cantero
- Cardiovascular Surgery Department, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| | - Verónica Blanco-Marquez
- Anesthesia Service, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| | | | - Juan C Santos-Jiménez
- Cardiovascular Surgery Department, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| | | | - José Garnacho-Montero
- Intensive Care Unit, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| | - Víctor Sánchez-Margalet
- Clinical Biochemistry Department, Virgen Macarena University Hospital, University of Seville, Sevilla, Spain
| |
Collapse
|
7
|
Song P, Holmes M, Mackensen GB. Cardiac Surgery. Perioper Med (Lond) 2022. [DOI: 10.1016/b978-0-323-56724-4.00031-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
8
|
Thromboelastography and rotational thromboelastometry in bleeding patients with coagulopathy: Practice management guideline from the Eastern Association for the Surgery of Trauma. J Trauma Acute Care Surg 2021; 89:999-1017. [PMID: 32941349 DOI: 10.1097/ta.0000000000002944] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Assessment of the immediate need for specific blood product transfusions in acutely bleeding patients is challenging. Clinical assessment and commonly used coagulation tests are inaccurate and time-consuming. The goal of this practice management guideline was to evaluate the role of the viscoelasticity tests, which are thromboelastography (TEG) and rotational thromboelastometry (ROTEM), in the management of acutely bleeding trauma, surgical, and critically ill patients. METHODS Systematic review and meta-analyses of manuscripts comparing TEG/ROTEM with non-TEG/ROTEM-guided blood products transfusions strategies were performed. The Grading of Recommendations Assessment, Development and Evaluation methodology was applied to assess the level of evidence and create recommendations for TEG/ROTEM-guided blood product transfusions in adult trauma, surgical, and critically ill patients. RESULTS Using TEG/ROTEM-guided blood transfusions in acutely bleeding trauma, surgical, and critically ill patients was associated with a tendency to fewer blood product transfusions in all populations. Thromboelastography/ROTEM-guided transfusions were associated with a reduced number of additional invasive hemostatic interventions (angioembolic, endoscopic, or surgical) in surgical patients. Thromboelastography/ROTEM-guided transfusions were associated with a reduction in mortality in trauma patients. CONCLUSION In patients with ongoing hemorrhage and concern for coagulopathy, we conditionally recommend using TEG/ROTEM-guided transfusions, compared with traditional coagulation parameters, to guide blood component transfusions in each of the following three groups: adult trauma patients, adult surgical patients, and adult patients with critical illness. LEVEL OF EVIDENCE Systematic Review/Meta-Analysis, level III.
Collapse
|
9
|
Thromboelastography-Is It the Freeway or Part of the Road to Anticoagulation Management During Pediatric Extracorporeal Membrane Oxygenation? Pediatr Crit Care Med 2021; 22:326-329. [PMID: 33657614 DOI: 10.1097/pcc.0000000000002674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Jiménez Rivera JJ, Llanos Jorge C, López Gude MJ, Pérez Vela JL. Perioperative management in cardiovascular surgery. Med Intensiva 2020; 45:175-183. [PMID: 33358388 DOI: 10.1016/j.medin.2020.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 10/29/2020] [Indexed: 12/21/2022]
Abstract
Cardio-surgical patient care requires a comprehensive and multidisciplinary approach to develop strategies to improve patient safety and outcomes. In the preoperative period, prophylaxis for frequent postoperative complications, such as de novo atrial fibrillation or bleeding, and prehabilitation based on exercise training, respiratory physiotherapy and nutritional and cognitive therapy, especially in fragile patients, stand out. There have been great advances, during the intraoperative phase, such as minimally invasive surgery, improved myocardial preservation, enhanced systemic perfusion and brain protection during extracorporeal circulation, or implementation of Safe Surgery protocols. Postoperative care should include goal-directed hemodynamic theraphy, a correct approach to coagulation disorders, and a multimodal analgesic protocol to facilitate early extubation and mobilization. Finally, optimal management of postoperative complications is key, including arrhythmias, vasoplegia, bleeding, and myocardial stunning that can lead to low cardiac output syndrome or, in extreme cases, cardiogenic shock. This global approach and the high degree of complexity require highly specialised units where intensive care specialists add value and are key to obtain more effective and efficient clinical results.
Collapse
Affiliation(s)
- J J Jiménez Rivera
- Servicio de Medicina Intensiva, Hospital Universitario de Canarias, La Laguna, España.
| | - C Llanos Jorge
- Servicio de Medicina Intensiva, Hospital Quirón salud Tenerife, Santa Cruz de Tenerife, España
| | - M J López Gude
- Servicio de Cirugía Cardiovascular, Hospital Universitario Doce de Octubre, Madrid, España
| | - J L Pérez Vela
- Servicio de Medicina Intensiva, Hospital Universitario Doce de Octubre, Madrid, España
| | | |
Collapse
|
11
|
Scala E, Marcucci C. Massive Hemorrhage: The Role of Whole Blood Viscoelastic Assays. Hamostaseologie 2020; 40:515-523. [PMID: 33091949 DOI: 10.1055/a-1227-8050] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Viscoelastic whole blood tests are increasingly used to guide hemostatic therapy in bleeding patients in the perioperative, trauma, and obstetric settings. Compared with standard laboratory tests of hemostasis, they have a shorter turnaround time and provide simultaneous information on various aspects of clot formation and lysis. The two available brands TEG (thromboelastography) and ROTEM (rotational thromboelastometry) provide devices that are either manually operated or fully automated. The automation allows for the assays to be used as point-of-care tests increasing their usefulness in massively bleeding patients with rapidly changing hemostatic profiles. While the number of research papers on the subject and the number of published treatment algorithms increase rapidly, the influence of the use of these devices on patient outcome needs yet to be established. In this article, we first review the technology of these devices and the parameters provided by the assays. Next, we present the problems encountered when choosing cut-off values that trigger intervention. Furthermore, we discuss the studies examining their influence on clinical outcomes, and finally, we briefly highlight some of the most important limitations and pitfalls inherent to these assays.
Collapse
Affiliation(s)
- Emmanuelle Scala
- Department of Anesthesiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Carlo Marcucci
- Department of Anesthesiology, Lausanne University Hospital, Lausanne, Switzerland.,Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
12
|
Rotational thromboelastometry (ROTEM)-enhanced transfusion strategy: Is it time to be specific and prospective? J Clin Anesth 2020; 67:110034. [PMID: 32927236 DOI: 10.1016/j.jclinane.2020.110034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 09/01/2020] [Indexed: 11/23/2022]
|
13
|
Retrospective Analysis of Thromboelastography-Directed Transfusion in Isolated CABG: Impact on Blood Product Use, Cost, and Outcomes. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2020; 52:103-111. [PMID: 32669736 DOI: 10.1182/ject-2000007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 03/30/2020] [Indexed: 11/20/2022]
Abstract
Cardiac surgeries account for approximately 20% of blood use in the United States. Allogeneic transfusion has been associated with increased risk of morbidity and mortality, further justifying the need to reduce blood use. This study aimed at determining whether a point-of-care coagulation test, thromboelastography (TEG), impacted blood product administration and outcomes. Patients undergoing isolated coronary artery bypass grafting (CABG) were retrospectively reviewed before the use of TEG (2008-2009) (n = 640) and after implementation (2011-2012) (n = 458). Blood product use was compared between time frames. Logistic regression and generalized linear models were created to estimate the impact on outcomes including the reoperation rate, mortality, and cost. The mean use of each blood product was significantly reduced in the perioperative period. Overall blood product use was decreased by over 40%. Mediastinal re-exploration of bleeding was significantly reduced with TEG (4.8 vs. 1.5%). Six-month mortality was not impacted in this cohort nor was the readmission rate or hospital length of stay. However, blood cost and patient charges were significantly lower after TEG was introduced. The use of TEG to guide the administration of blood products during isolated CABG significantly affected the amounts and types of products given intra- and perioperatively. This resulted in less chest tube drainage, fewer returns to the operating room, and more accurate diagnosis of coagulopathic status. Cost savings to the patient and institution were appreciated as a consequence of these improved clinical outcomes.
Collapse
|
14
|
Wand S, Heise D, Hillmann N, Bireta C, Bräuer A, Ahsen NV, Quintel M. Is There a "Blind Spot" in Point-of-Care Testing for Residual Heparin After Cardiopulmonary Bypass? A Prospective, Observational Cohort Study. Clin Appl Thromb Hemost 2020; 26:1076029620946843. [PMID: 32795187 PMCID: PMC7430071 DOI: 10.1177/1076029620946843] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Identifying the cause of a bleeding complication after cardiac surgery can be crucial. This study sought to clarify whether the application of unprocessed autologous pump blood influences anti-factor Xa activity after cardiac surgery and evaluated 2 point-of-care methods regarding their ability to identify an elevated anti-factor Xa activity at different timepoints after cardiopulmonary bypass. Anti-factor Xa activity, heparin/protamine titration and the clotting time ratio of thromboelastometry in the INTEM and HEPTEM were measured at baseline (T1), after the application of protamine (T2) and after the complete application of autologous pump blood (T3). Anti-factor Xa activity decreased significantly between T2 and T3 as well did the absolute number of patients with an elevated anti-factor Xa activity. Receiver Operating Curve analyses were performed for both point-of-care methods. At T2 neither could identify patients with an elevated anti-factor Xa activity, while both methods were able to do so at T3 with high sensitivity and specificity. This difference suggests that an interference in the detection of residual heparinization with point-of-care methods exists right after the application of protamine, which seems to subside after a short time span. Nevertheless, results of point-of-care testing for residual heparinization after cardiopulmonary bypass need to be interpreted considering the protamine-heparin ratio and the timepoint of protamine administration.
Collapse
Affiliation(s)
- Saskia Wand
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany.,Department of Anesthesiology, Ruhr-University Bochum, St. Josef- and St. Elisabeth Hospital, Bochum, Germany
| | - Daniel Heise
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - Nadine Hillmann
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - Christian Bireta
- Department of Thoracic, Cardiac and Vascular Surgery, University Medical Center Goettingen, Germany
| | - Anselm Bräuer
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| | - Nicolas von Ahsen
- Department of Clinical Chemistry, University Medical Center Goettingen, University Medical Center Goettingen, Goettingen, Germany
| | - Michael Quintel
- Department of Anesthesiology, University Medical Center Goettingen, Goettingen, Germany
| |
Collapse
|
15
|
Najafi A, Jafarian A, Makarem J, Barzin G, Salimi J, Nasiri-Toosi M, Moini M, Ebrahimi A, Behboudi B, Mohammadpour Z, Shariat Moharari R. Comparison of Coagulation Conditions in Patients With Liver Cirrhosis Due to Primary Sclerosing Cholangitis and Nonbiliary Causes of Cirrhosis Before Orthotopic Liver Transplant. EXP CLIN TRANSPLANT 2020; 18:696-700. [PMID: 32552627 DOI: 10.6002/ect.2018.0374] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVES Orthotopic liver transplant can be accompanied by an obscure bleeding pattern in patients with severe hepatic malfunction. In the present study, coagulation conditions of patients with cirrhosis of the liver due to primary sclerosing cholangitis and nonbiliary causes of cirrhosis were compared using rotational thromboelastometry assays obtained before orthotopic liver transplant. MATERIALS AND METHODS This case control study analyzed patients who were candidates for orthotopic liver transplant from 2010 to 2016. Eighty patients with cirrhosis of the liver (40 patients with primary sclerosing cholangitis and 40 with nonbiliary causes of cirrhosis) were randomly selected and enrolled into the study. Patients received rotational thromboelastometry assays under anesthesia just before the start of the operation, and results were compared between the 2 patient groups. RESULTS Of 80 patients, 52 were men and 28 were women. In the assays, we found that maximum amplitudes in 10 and in 20 minutes and maximum clot firmness parameters were higher in patients with primary sclerosing cholangitis. The alpha angle and clot formation time were different in the intrinsic and extrinsic assay panels. In the intrinsic assay, we found clotting time to be shorter (P < .05). The average of all parameters in all 3 assays (intrinsic, extrinsic, and fibrinogen contribution) was lower in patients with nonbiliary causes of cirrhosis than in those with primary sclerosing cholangitis. CONCLUSIONS In contrast with previous studies that found that patients with primary sclerosing cholangitis are hypercoagulable, our study observed that they have normal coagulable results. Furthermore, we found that, although mean coagulation indexes in patients with primary sclerosing cholangitis were within normal ranges, in patients with nonbiliary causes of cirrhosis, these indexes were generally lower.
Collapse
Affiliation(s)
- Atabak Najafi
- From the Liver Transplantation Research Center, Imam Khomeini Hospital Complex, and the Department of Anesthesiology and Critical Care, Tehran University of Medical Sciences, Sina Hospital, Tehran, Iran
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Paarup HM, Rasmussen MH, Yazer MH, Sprogøe U. Performance characteristics of thromboelastometry assays using incompletely filled and prolonged stored samples. Transfusion 2020; 60 Suppl 3:S107-S111. [PMID: 32478884 DOI: 10.1111/trf.15611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 11/13/2019] [Accepted: 11/13/2019] [Indexed: 11/28/2022]
Abstract
BACKGROUND Thromboelastometry (TEM) is often used to guide transfusion therapy in patients with massive bleeding. The effect of testing incompletely filled samples and those stored for a prolonged time at 4°C was investigated. METHODS Whole blood samples were collected from 15 healthy blood donors and were pooled according to ABO group. From these pools, aliquots were taken and diluted to produce final whole blood:citrate buffer ratios ranging from 90:10 (fully filled sample) to 40:60 (extremely under filled samples). These samples were then tested by EXTEM, INTEM, and FIBTEM on calibrated ROTEM delta machines. Separately, the four samples at 90:10 dilution were kept at 4°C for 16-20 hours and then retested on the ROTEM machines. RESULTS All of the samples at the 90:10 and 80:20 (half-filled sample) whole blood:citrate buffer dilutions demonstrated ROTEM parameters within their respective reference ranges, although the samples from the 80:20 dilution tended to demonstrate slightly longer or slower times, depending on each ROTEM parameter, compared to the completely filled samples. All of the samples with more dilute whole blood to citrate buffer ratios (i.e., 70:30 to 40:60) yielded abnormal TEM results. The TEM results for the 90:10 dilution samples exposed to 16-20 hours of storage at 4°C were within the reference intervals. CONCLUSION Completely and half-filled samples, and completely filled samples after prolonged cold storage, produced normal ROTEM results. Tubes that are less than half-filled should not be used for ROTEM testing.
Collapse
Affiliation(s)
- Helene M Paarup
- Department of Clinical Immunology, Odense University Hospital, Odense, Denmark
| | - Mads H Rasmussen
- Department of Clinical Immunology, Odense University Hospital, Odense, Denmark
| | - Mark H Yazer
- Department of Clinical Immunology, Odense University Hospital, Odense, Denmark.,Department of Pathology, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Ulrik Sprogøe
- Department of Clinical Immunology, Odense University Hospital, Odense, Denmark
| |
Collapse
|
17
|
Hartmann J, Murphy M, Dias JD. Viscoelastic Hemostatic Assays: Moving from the Laboratory to the Site of Care-A Review of Established and Emerging Technologies. Diagnostics (Basel) 2020; 10:diagnostics10020118. [PMID: 32098161 PMCID: PMC7167835 DOI: 10.3390/diagnostics10020118] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/17/2020] [Accepted: 02/19/2020] [Indexed: 11/16/2022] Open
Abstract
Viscoelastic-based techniques to evaluate whole blood hemostasis have advanced substantially since they were first developed over 70 years ago but are still based upon the techniques first described by Dr. Hellmut Hartert in 1948. Today, the use of thromboelastography, the method of testing viscoelastic properties of blood coagulation, has moved out of the research laboratory and is now more widespread, used commonly during surgery, in emergency departments, intensive care units, and in labor wards. Thromboelastography is currently a rapidly growing field of technological advancement and is attracting significant investment. This review will first describe the history of the viscoelastic testing and the established first-generation devices, which were developed for use within the laboratory. This review will then describe the next-generation hemostasis monitoring devices, which were developed for use at the site of care for an expanding range of clinical applications. This review will then move on to experimental technologies, which promise to make viscoelastic testing more readily available in a wider range of clinical environments in the endeavor to improve patient care.
Collapse
Affiliation(s)
- Jan Hartmann
- Haemonetics Corporation, Boston, MA 02110, USA;
- Correspondence: ; Tel.: +1-781-348-7396
| | | | - Joao D. Dias
- Haemonetics SA, Signy CH, 1274 Signy-Centre, Switzerland;
| |
Collapse
|
18
|
Terada R, Ikeda T, Mori Y, Yamazaki S, Kashiwabara K, Yamauchi H, Ono M, Yamada Y, Okazaki H. Comparison of two point of care whole blood coagulation analysis devices and conventional coagulation tests as a predicting tool of perioperative bleeding in adult cardiac surgery-a pilot prospective observational study in Japan. Transfusion 2019; 59:3525-3535. [PMID: 31614002 DOI: 10.1111/trf.15523] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Revised: 06/10/2019] [Accepted: 08/13/2019] [Indexed: 12/12/2022]
Abstract
BACKGROUND It is widely accepted that Point-of Care Test (PoCT) devices are useful in the detection of coagulopathies in situations of massive bleeding such as major cardiac surgery. These devices contribute to the reduction of blood transfusion. However, their implementation remains limited in Japan because of their cost and lack of health insurance support. STUDY DESIGN AND METHODS Conventional coagulation tests and thromboelastography (TEG)/Sonoclot values were measured in 50 consecutive cardiac surgery cases. Clinical background information such as operative procedures was obtained from electronic medical records, and the theoretical perioperative total blood loss was calculated by measuring the hemoglobin content and total red blood cell transfusion volume. The correlation between perioperative total blood loss and the measured laboratory values or clinical parameters was evaluated by a multivariate linear regression analysis. The risk factors of the total amount of platelet transfusion and postoperative drain bleeding volume were similarly evaluated. RESULTS No significant association between the estimated perioperative total blood loss (eTBL) and the laboratory measurements including conventional coagulation tests, TEG and Sonoclot was observed. On the other hand, postoperative drain bleeding volume was significantly associated with postoperative Sonoclot CR (p = 0.039) as well as preoperative use of oral anticoagulants and cell saver treated blood volume. Platelet transfusion amount was significantly associated with post-CBP PF and time to peak value of Sonoclot (p = 0.014 and 0.001, respectively). CONCLUSION Sonoclot measurements may be useful to estimate the risks of postoperative bleeding and platelet transfusion in cardiac surgeries in Japan.
Collapse
Affiliation(s)
- Rui Terada
- Department of Blood Transfusion, The University of Tokyo Hospital, Tokyo, Japan
| | - Toshiyuki Ikeda
- Department of Blood Transfusion, The University of Tokyo Hospital, Tokyo, Japan
| | - Yoshiteru Mori
- Department of Anesthesiology and Pain Relief Center, The University of Tokyo Hospital, Tokyo, Japan
| | - Sho Yamazaki
- Department of Blood Transfusion, The University of Tokyo Hospital, Tokyo, Japan
| | - Kosuke Kashiwabara
- Department of Biostatistics Division, Clinical Research Support Center, The University of Tokyo Hospital, Tokyo, Japan
| | - Haruo Yamauchi
- Department of Cardiac Surgery, The University of Tokyo Hospital, Tokyo, Japan
| | - Minoru Ono
- Department of Cardiac Surgery, The University of Tokyo Hospital, Tokyo, Japan
| | - Yoshitsugu Yamada
- Department of Anesthesiology and Pain Relief Center, The University of Tokyo Hospital, Tokyo, Japan
| | - Hitoshi Okazaki
- Department of Blood Transfusion, The University of Tokyo Hospital, Tokyo, Japan
| |
Collapse
|
19
|
Schmidt AE, Israel AK, Refaai MA. The Utility of Thromboelastography to Guide Blood Product Transfusion. Am J Clin Pathol 2019; 152:407-422. [PMID: 31263903 DOI: 10.1093/ajcp/aqz074] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVES To provide an overview of the clot viscoelastic testing technology and to describe its utility in guiding blood product transfusions. METHODS A case scenario will be discussed as well as interpretation of thromboelastography (TEG) tracings. In addition, literature examining the utility of viscoelastic testing in guiding patient management and blood product transfusions will be reviewed. RESULTS TEG/rotational thromboelastometry (ROTEM) is useful in evaluating clot kinetics in trauma and acutely bleeding patients. TEG/ROTEM parameters are reflective of values measured using standard coagulation assays; however, TEG/ROTEM parameters are more rapidly available and more costly. TEG and ROTEM are used in three main settings: cardiac surgery, liver transplantation, and trauma to assess global hemostasis and administration of blood products. CONCLUSIONS TEG/ROTEM can be helpful in guiding resuscitation and blood product transfusion. Several studies have demonstrated a reduction in transfusion of blood components with TEG/ROTEM; however, other studies have suggested that TEG/ROTEM is not clinically effective in guiding transfusion.
Collapse
Affiliation(s)
- Amy E Schmidt
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY
| | - Anna Karolina Israel
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY
| | - Majed A Refaai
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY
| |
Collapse
|
20
|
Redfern RE, Fleming K, March RL, Bobulski N, Kuehne M, Chen JT, Moront M. Thromboelastography-Directed Transfusion in Cardiac Surgery: Impact on Postoperative Outcomes. Ann Thorac Surg 2019; 107:1313-1318. [DOI: 10.1016/j.athoracsur.2019.01.018] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 12/11/2018] [Accepted: 01/07/2019] [Indexed: 01/08/2023]
|
21
|
Li C, Zhao Q, Yang K, Jiang L, Yu J. Thromboelastography or rotational thromboelastometry for bleeding management in adults undergoing cardiac surgery: a systematic review with meta-analysis and trial sequential analysis. J Thorac Dis 2019; 11:1170-1181. [PMID: 31179059 DOI: 10.21037/jtd.2019.04.39] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Severe bleeding and massive transfusion of blood products may be associated with increased morbidity and mortality of cardiac surgery. A transfusion algorithm incorporating thromboelastography (TEG) or rotational thromboelastometry (ROTEM) can help to determine the appropriate time and target for the use of hemostatic blood products, which may thus reduce the quantity of blood loss as well as blood products transfused. Methods We conducted meta-analysis and trial sequential analysis to evaluate the effects of TEG or ROTEM-guided transfusion algorithms vs. standard treatments for patients undergoing cardiac surgery with cardiac pulmonary bypass. Results Nineteen studies with a total of 15,320 participants, including 13 randomized controlled trials (RCTs), were included. All-cause mortality was not reduced either in overall studies or in RCTs. Blood loss volume was reduced by 132 mL in overall studies [mean difference (MD): -132.46, 95% CI: -207.49, -57.43; I2 =53%, P<0.01], and by 103 mL in RCTs (MD: -103.50, 95% CI: -156.52, -50.48; I2 =0%, P<0.01). The relative risks (RRs) in RCTs were 0.89 (95% CI: 0.80-0.98; I2 =0%, P=0.02) for red blood cells transfusion, 0.59 (95% CI: 0.42-0.82; I2 =55%, P<0.01) for fresh frozen plasma transfusion, and 0.81 (95% CI: 0.74-0.90; I2 =0%, P<0.01) for platelet transfusion, respectively. Trial sequential analysis of continuous data on blood loss and dichotomous outcomes on transfusion of blood products suggested the benefits of a TEG/ROTEM-guided algorithm. Conclusions TEG or ROTEM-guided transfusion strategies may reduce blood loss volume and the transfusion rates in adult patients undergoing cardiac surgery.
Collapse
Affiliation(s)
- Caie Li
- Lanzhou University Second Hospital, Lanzhou 730030, China
| | - Qiming Zhao
- Department of Cardiac Surgery ICU, Lanzhou University Second Hospital, Lanzhou 730030, China
| | - Kun Yang
- Department of Cardiac Surgery ICU, Lanzhou University Second Hospital, Lanzhou 730030, China
| | - Luxia Jiang
- Department of Cardiac Surgery ICU, Lanzhou University Second Hospital, Lanzhou 730030, China
| | - Jing Yu
- Department of Cardiology, Lanzhou University Second Hospital, Lanzhou 730030, China
| |
Collapse
|
22
|
Hawkins RB, Raymond SL, Hartjes T, Efron PA, Larson SD, Andreoni KA, Thomas EM. Review: The Perioperative Use of Thromboelastography for Liver Transplant Patients. Transplant Proc 2018; 50:3552-3558. [PMID: 30577236 DOI: 10.1016/j.transproceed.2018.07.032] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 07/09/2018] [Accepted: 07/18/2018] [Indexed: 12/12/2022]
Abstract
Thromboelastography (TEG) is a viscoelastic test that allows rapid evaluation of clot formation and fibrinolysis from a sample of whole blood. TEG is increasingly utilized to guide blood product resuscitation in surgical patients and transfusions for liver transplant patients. Patients with severe liver failure have significant derangement of their clotting function due to impaired production of procoagulant and anticoagulant factors. Traditional coagulation studies are limited by the short time needed for the result and provide little information about the dynamics and strength of clot formation. In addition, traditional coagulation studies do not correlate well with bleeding episodes and may lead to over-transfusion of various blood products. Evidence is less robust regarding the use of TEG for transfusion management decisions in severe liver failure patients awaiting, undergoing, or immediately after liver transplant surgery. However, the available evidence suggests that systematic implementation of TEG rather than traditional coagulation studies results in the administration of fewer blood products without increased mortality or complications. The purpose of this study is to review the literature regarding the use of TEG in liver failure patients prior to liver transplant, intraoperatively, and postoperatively. Additional high-quality randomized controlled studies should be performed to evaluate the use of TEG to guide transfusion decisions, particularly in the postoperative period following liver transplantation.
Collapse
Affiliation(s)
- R B Hawkins
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA
| | - S L Raymond
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA
| | - T Hartjes
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA; University of Florida College of Nursing, Gainesville, FL, USA
| | - P A Efron
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA
| | - S D Larson
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA
| | - K A Andreoni
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA
| | - E M Thomas
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL, USA.
| |
Collapse
|
23
|
Ünlü A, Yılmaz S, Yalçın Ö, Uyanık M, Petrone P, Çetinkaya RA, Eker İ, Urkan M, Özgürtaş T, Avcı İY, Zeybek N, Aksu AC. Bringing Packed Red Blood Cells to the Point of Combat Injury: Are We There Yet? Turk J Haematol 2018; 35:185-191. [PMID: 29806595 PMCID: PMC6110438 DOI: 10.4274/tjh.2018.0081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Accepted: 05/28/2018] [Indexed: 12/01/2022] Open
Abstract
Objective Hemorrhage is the leading cause of injury-related prehospital mortality. We investigated worst-case scenarios and possible requirements of the Turkish military. As we plan to use blood resources during casualty transport, the impact of transport-related mechanical stress on packed red blood cells (PRBCs) was analyzed. Materials and Methods The in vitro experiment was performed in the environmental test laboratories of ASELSAN®. Operational vibrations of potential casualty transport mediums such as Sikorsky helicopters, Kirpi® armored vehicles, and the NATO vibration standard MIL-STD-810G software program were recorded. The most powerful mechanical stress, which was created by the NATO standard, was applied to 15 units of fresh (≤7 days) and 10 units of old (>7 days) PRBCs in a blood cooler box. The vibrations were simulated with a TDS v895 Medium-Force Shaker Device. On-site blood samples were analyzed at 0, 6, and 24 h for biochemical and biomechanical analyses. Results The mean (±standard deviation) age of fresh and old PRBCs was 4.9±2.2 and 32.8±11.8 days, respectively. Six-hour mechanical damage of fresh PRBCs was demonstrated by increased erythrocyte fragmentation rates (p=0.015), hemolysis rates (p=0.003), and supernatant potassium levels (p=0.003) and decreased hematocrit levels (p=0.015). Old PRBC hemolysis rates (p=0.015), supernatant potassium levels (p=0.015), and supernatant hemoglobin (p=0.015) were increased and hematocrit levels were decreased (p=0.015) within 6 h. Two (13%) units of fresh PRBCs and none of the old PRBCs were eligible for transfusion after 6 h of mechanical stress. Conclusion When an austere combat environment was simulated for 24 h, fresh and old PRBC hemolysis rates were above the quality criteria. Currently, the technology to overcome this mechanical damage does not seem to exist. In light of the above data, a new national project is being performed.
Collapse
Affiliation(s)
- Aytekin Ünlü
- University of Health Sciences, Gülhane Training and Research Hospital, Clinic of General Surgery, Ankara, Turkey
| | - Soner Yılmaz
- University of Health Sciences, Gülhane Training and Research Hospital, Regional Blood and Training Center, Ankara, Turkey
| | - Özlem Yalçın
- Koç University Faculty of Medicine, Laboratory of Hemorheology, Hemodynamics, and Vascular Biology, İstanbul, Turkey
| | - Metin Uyanık
- Çorlu State Hospital, Clinic of Biochemistry, Tekirdağ, Turkey
| | - Patrizio Petrone
- NYU Winthrop Hospital, Clinic of Surgery, Mineola; New York Medical College, Valhalla, New York, USA; University of Las Palmas de Gran Canaria, Canary Islands, Spain
| | - Rıza Aytaç Çetinkaya
- University of Health Sciences, Sultan Abdulhamid Han Training and Research Hospital, Clinic of Infectious Diseases, İstanbul, Turkey
| | - İbrahim Eker
- Afyon Kocatepe University Faculty of Medicine, Department of Pediatric Hematology, Afyonkarahisar, Turkey
| | - Murat Urkan
- University of Health Sciences, Gülhane Training and Research Hospital, Clinic of General Surgery, Ankara, Turkey
| | - Taner Özgürtaş
- University of Health Sciences, Gülhane Training and Research Hospital, Clinic of Biochemistry, Ankara, Turkey
| | - İsmail Yaşar Avcı
- University of Health Sciences, Gülhane Training and Research Hospital, Clinic of Infectious Diseases and Clinical Microbiology, Ankara, Turkey
| | - Nazif Zeybek
- University of Health Sciences, Gülhane Training and Research Hospital, Clinic of General Surgery, Ankara, Turkey
| | - Ali Cenk Aksu
- Koç University Faculty of Medicine, Laboratory of Hemorheology, Hemodynamics, and Vascular Biology, İstanbul, Turkey
| |
Collapse
|
24
|
Curry NS, Davenport R, Pavord S, Mallett SV, Kitchen D, Klein AA, Maybury H, Collins PW, Laffan M. The use of viscoelastic haemostatic assays in the management of major bleeding: A British Society for Haematology Guideline. Br J Haematol 2018; 182:789-806. [PMID: 30073664 DOI: 10.1111/bjh.15524] [Citation(s) in RCA: 124] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Nicola S Curry
- Department of Haematology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.,NIHR BRC, Blood Theme, Oxford University, Oxford, UK
| | - Ross Davenport
- Centre for Trauma Sciences, Blizard Institute, Queen Mary University of London, London, UK
| | - Sue Pavord
- Department of Haematology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.,NIHR BRC, Blood Theme, Oxford University, Oxford, UK
| | - Susan V Mallett
- Department of Anaesthesia, Royal Free London NHS Foundation Trust, London, UK
| | | | - Andrew A Klein
- Department of Anaesthesia and Intensive Care, Royal Papworth Hospital, Cambridge, UK
| | - Helena Maybury
- Department of Obstetrics, Leicester Royal Infirmary, Leicester, UK
| | - Peter W Collins
- Department of Haematology, School of Medicine, Cardiff University, Cardiff, UK
| | - Mike Laffan
- Department of Haematology, Imperial College and Hammersmith Hospital, London, UK
| |
Collapse
|
25
|
Crochemore T, Piza FMDT, Rodrigues RDR, Guerra JCDC, Ferraz LJR, Corrêa TD. A new era of thromboelastometry. ACTA ACUST UNITED AC 2017; 15:380-385. [PMID: 28614427 PMCID: PMC5823059 DOI: 10.1590/s1679-45082017md3130] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Accepted: 10/27/2016] [Indexed: 12/15/2022]
Abstract
Severe hemorrhage with necessity of allogeneic blood transfusion is common complication in intensive care unit and is associated with increased morbidity and mortality. Prompt recognition and treatment of bleeding causes becomes essential for the effective control of hemorrhage, rationalizing the use of allogeneic blood components, and in this way, preventing an occurrence of their potential adverse effects. Conventional coagulation tests such as prothrombin time and activated partial thromboplastin time present limitations in predicting bleeding and guiding transfusion therapy in critically ill patients. Viscoelastic tests such as thromboelastography and rotational thromboelastometry allow rapid detection of coagulopathy and goal-directed therapy with specific hemostatic drugs. The new era of thromboelastometry relies on its efficacy, practicality, reproducibility and cost-effectiveness to establish itself as the main diagnostic tool and transfusion guide in patients with severe active bleeding.
Collapse
|
26
|
Gendreau JL, Knoll C, Adams RH, Su LL. The Role of Thromboelastography in Pediatric Patients with Sinusoidal Obstructive Syndrome Receiving Defibrotide. Biol Blood Marrow Transplant 2017; 23:707-712. [PMID: 28115278 DOI: 10.1016/j.bbmt.2017.01.074] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Accepted: 01/13/2017] [Indexed: 10/20/2022]
Abstract
Sinusoidal obstructive syndrome (SOS) is a potentially fatal form of hepatic injury after hematopoietic stem cell transplantation. Patients can develop liver dysfunction, portal hypertension, ascites, coagulopathies, and multisystem organ failure. The mortality rate of severe SOS has been reported as high as 98% by day 100 after transplantation. Defibrotide, which is now approved for the treatment of SOS, has significantly decreased mortality. Defibrotide is a polynucleotide with profibrinolytic, anti-ischemic, and anti-inflammatory activity. These properties can increase the risk of life-threatening bleeding in this patient population. Previous protocols have suggested maintaining international normalized ratio ≤ 1.5, platelets > 30 k/uL, and fibrinogen ≥ 150 mg/dL to minimize this risk of bleeding. However, this can be challenging in fluid-sensitive patients with SOS. Thromboelastography (TEG) is a functional assay that evaluates the balance of procoagulant and anticoagulant proteins. In this series, TEG was used to guide defibrotide therapy as well as blood product transfusions in SOS patients with abnormal coagulation studies. Each patient recovered from SOS and had no bleeding complications. A randomized clinical trial is the next step in supporting the use of TEG in SOS patients with abnormal coagulation studies receiving defibrotide therapy.
Collapse
Affiliation(s)
- Joanna L Gendreau
- Center for Cancer and Blood Disorders, Phoenix Children's Hospital, Phoenix, Arizona.
| | - Christine Knoll
- Center for Cancer and Blood Disorders, Phoenix Children's Hospital, Phoenix, Arizona
| | - Roberta H Adams
- Center for Cancer and Blood Disorders, Phoenix Children's Hospital, Phoenix, Arizona; Hematology/Oncology, Mayo Clinic Arizona, Scottsdale, Arizona
| | - Leon L Su
- Department of Pathology and Laboratory Medicine, Phoenix Children's Hospital, Phoenix, Arizona
| |
Collapse
|
27
|
Huffmyer JL, Fernandez LG, Haghighian C, Terkawi AS, Groves DS. Comparison of SEER Sonorheometry With Rotational Thromboelastometry and Laboratory Parameters in Cardiac Surgery. Anesth Analg 2016; 123:1390-1399. [DOI: 10.1213/ane.0000000000001507] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
28
|
Kim JY, Shin YR, Kil HK, Park MR, Lee JW. Reference Intervals of Thromboelastometric Evaluation of Coagulation in Pediatric Patients with Congenital Heart Diseases: A Retrospective Investigation. Med Sci Monit 2016; 22:3576-3587. [PMID: 27711024 PMCID: PMC5065290 DOI: 10.12659/msm.901256] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Background Rotational thromboelastometry (ROTEM®) is a point-of-care test for coagulation, enabling physicians to make a swift decision. The aim of this investigation was to establish reference intervals of thromboelastometric evaluation for coagulation in pediatric patients with congenital heart diseases (CHD). Material/Methods As baseline data, 3 assays of ROTEM® (INTEM, EXTEM, and FIBTEM) were measured after anesthesia induction. ROTEM® parameters were clotting time (CT), amplitude at 10 min (A10), clot formation time (CFT), α angle, maximal clot firmness (MCF), clot lysis index at 60 min (LI60), and maximal clot elasticity (MCE). As age is a well-known factor for maturation, age groups were determined as follows; 1) <1 month, 2) 1–3 months, 3) 4–12 months, 4) 1–3 years, 5) 4–6 years, 6) 7–12 years, and 7) 13–16 years. Reference limits representing 95% of distribution of ROTEM® parameters and 90% confidence intervals of upper and lower reference limits were calculated. Results The data of 413 patients were analyzed. Although INTEM CT was prolonged, significantly shorter CT and CFT, steeper α, and greater A10, MCF, and MCE were shown in patients age <3 months compared to older children. Conclusions Reference intervals of thromboelastometric evaluation for coagulation from pediatric patients with CHD were shown to have similar pattern to those obtained from healthy pediatric patients. Pediatric patients with CHD, even with cyanosis, were demonstrated to have functionally intact coagulation profile before surgery.
Collapse
Affiliation(s)
- Ji Young Kim
- Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul, South Korea
| | - Yu Rim Shin
- Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Department of Thoracic and Cardiovascular Surgery, Yonsei University College of Medicine, Seoul, South Korea
| | - Hae Keum Kil
- Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul, South Korea
| | - Mi Ran Park
- Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul, South Korea
| | - Jong Wha Lee
- Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
29
|
Attributable harm of severe bleeding after cardiac surgery in hemodynamically stable patients. Gen Thorac Cardiovasc Surg 2016; 65:102-109. [DOI: 10.1007/s11748-016-0714-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Accepted: 09/09/2016] [Indexed: 10/21/2022]
|
30
|
Wikkelsø A, Wetterslev J, Møller AM, Afshari A. Thromboelastography (TEG) or thromboelastometry (ROTEM) to monitor haemostatic treatment versus usual care in adults or children with bleeding. Cochrane Database Syst Rev 2016; 2016:CD007871. [PMID: 27552162 PMCID: PMC6472507 DOI: 10.1002/14651858.cd007871.pub3] [Citation(s) in RCA: 133] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND Severe bleeding and coagulopathy are serious clinical conditions that are associated with high mortality. Thromboelastography (TEG) and thromboelastometry (ROTEM) are increasingly used to guide transfusion strategy but their roles remain disputed. This review was first published in 2011 and updated in January 2016. OBJECTIVES We assessed the benefits and harms of thromboelastography (TEG)-guided or thromboelastometry (ROTEM)-guided transfusion in adults and children with bleeding. We looked at various outcomes, such as overall mortality and bleeding events, conducted subgroup and sensitivity analyses, examined the role of bias, and applied trial sequential analyses (TSAs) to examine the amount of evidence gathered so far. SEARCH METHODS In this updated review we identified randomized controlled trials (RCTs) from the following electronic databases: Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 1); MEDLINE; Embase; Science Citation Index Expanded; International Web of Science; CINAHL; LILACS; and the Chinese Biomedical Literature Database (up to 5 January 2016). We contacted trial authors, authors of previous reviews, and manufacturers in the field. The original search was run in October 2010. SELECTION CRITERIA We included all RCTs, irrespective of blinding or language, that compared transfusion guided by TEG or ROTEM to transfusion guided by clinical judgement, guided by standard laboratory tests, or a combination. We also included interventional algorithms including both TEG or ROTEM in combination with standard laboratory tests or other devices. The primary analysis included trials on TEG or ROTEM versus any comparator. DATA COLLECTION AND ANALYSIS Two review authors independently abstracted data; we resolved any disagreements by discussion. We presented pooled estimates of the intervention effects on dichotomous outcomes as risk ratio (RR) with 95% confidence intervals (CIs). Due to skewed data, meta-analysis was not provided for continuous outcome data. Our primary outcome measure was all-cause mortality. We performed subgroup and sensitivity analyses to assess the effect based on the presence of coagulopathy of a TEG- or ROTEM-guided algorithm, and in adults and children on various clinical and physiological outcomes. We assessed the risk of bias through assessment of trial methodological components and the risk of random error through TSA. MAIN RESULTS We included eight new studies (617 participants) in this updated review. In total we included 17 studies (1493 participants). A total of 15 trials provided data for the meta-analyses. We judged only two trials as low risk of bias. The majority of studies included participants undergoing cardiac surgery.We found six ongoing trials but were unable to retrieve any data from them. Compared with transfusion guided by any method, TEG or ROTEM seemed to reduce overall mortality (7.4% versus 3.9%; risk ratio (RR) 0.52, 95% CI 0.28 to 0.95; I(2) = 0%, 8 studies, 717 participants, low quality of evidence) but only eight trials provided data on mortality, and two were zero event trials. Our analyses demonstrated a statistically significant effect of TEG or ROTEM compared to any comparison on the proportion of participants transfused with pooled red blood cells (PRBCs) (RR 0.86, 95% CI 0.79 to 0.94; I(2) = 0%, 10 studies, 832 participants, low quality of evidence), fresh frozen plasma (FFP) (RR 0.57, 95% CI 0.33 to 0.96; I(2) = 86%, 8 studies, 761 participants, low quality of evidence), platelets (RR 0.73, 95% CI 0.60 to 0.88; I(2) = 0%, 10 studies, 832 participants, low quality of evidence), and overall haemostatic transfusion with FFP or platelets (low quality of evidence). Meta-analyses also showed fewer participants with dialysis-dependent renal failure.We found no difference in the proportion needing surgical reinterventions (RR 0.75, 95% CI 0.50 to 1.10; I(2) = 0%, 9 studies, 887 participants, low quality of evidence) and excessive bleeding events or massive transfusion (RR 0.38, 95% CI 0.38 to 1.77; I(2) = 34%, 2 studies, 280 participants, low quality of evidence). The planned subgroup analyses failed to show any significant differences.We graded the quality of evidence as low based on the high risk of bias in the studies, large heterogeneity, low number of events, imprecision, and indirectness. TSA indicates that only 54% of required information size has been reached so far in regards to mortality, while there may be evidence of benefit for transfusion outcomes. Overall, evaluated outcomes were consistent with a benefit in favour of a TEG- or ROTEM-guided transfusion in bleeding patients. AUTHORS' CONCLUSIONS There is growing evidence that application of TEG- or ROTEM-guided transfusion strategies may reduce the need for blood products, and improve morbidity in patients with bleeding. However, these results are primarily based on trials of elective cardiac surgery involving cardiopulmonary bypass, and the level of evidence remains low. Further evaluation of TEG- or ROTEM-guided transfusion in acute settings and other patient categories in low risk of bias studies is needed.
Collapse
Affiliation(s)
- Anne Wikkelsø
- Hvidovre Hospital, University of CopenhagenDepartment of Anaesthesiology and Intensive Care MedicineKettegård Alle 30,HvidovreDenmark2650
| | - Jørn Wetterslev
- Department 7812, Rigshospitalet, Copenhagen University HospitalCopenhagen Trial Unit, Centre for Clinical Intervention ResearchBlegdamsvej 9CopenhagenDenmarkDK‐2100
| | - Ann Merete Møller
- Herlev and Gentofte Hospital, University of CopenhagenCochrane Anaesthesia, Critical and Emergency Care GroupHerlev RingvejHerlevDenmark2730
| | - Arash Afshari
- Rigshospitalet, Copenhagen University HospitalJuliane Marie Centre ‐ Anaesthesia and Surgical Clinic Department 4013CopenhagenDenmark
| | | |
Collapse
|
31
|
Shander A, Moskowitz D, Rijhwani TS. The Safety and Efficacy of “Bloodless” Cardiac Surgery. Semin Cardiothorac Vasc Anesth 2016; 9:53-63. [PMID: 15735844 DOI: 10.1177/108925320500900106] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Nearly 20% of blood transfusions in the United States are associated with cardiac surgery. Despite the many blood conservation techniques that are available, safe, and efficacious for patients undergoing cardiac surgery, many of these operations continue to be associated with significant amounts of blood transfusion. Although surgical bleeding after cardiopulmonary bypass is a common problem as reflected by the substantial use of blood products, it is the individual physician and institutional behavior that have been identified as reasons for transfusion and not necessarily patient comorbidity or blood loss. Transfusion rates in cardiac surgery remain high despite major advances in perioperative blood conservation, with large variations among individual centers. The adoption of available blood conservation techniques, either alone or in combination in patients undergoing cardiac surgery, could result in an estimated 75% reduction of unnecessary transfusions. The success of previously reported blood conservations programs in cardiac surgery should call for a reevaluation of allogeneic transfusion practices in patients undergoing cardiac surgery. By applying the numerous reported blood conservation strategies for the management of patients presenting for cardiac surgery, we can preserve our dwindling blood resources and help alleviate some of the direct costs of blood as well as the indirect costs of treating noninfectious and infectious complications of transfusion.
Collapse
Affiliation(s)
- Aryeh Shander
- Critical Care Medicine, Pain Management and Hyperbaric Medicine, Englewood Hospital and Medical Center, Englewood, NJ 07361, USA.
| | | | | |
Collapse
|
32
|
Shore-Lesserson L. Evidence Based Coagulation Monitors: Heparin Monitoring, Thromboelastography, and Platelet Function. Semin Cardiothorac Vasc Anesth 2016; 9:41-52. [PMID: 15735843 DOI: 10.1177/108925320500900105] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The hemostatic management of patients undergoing cardiac surgery is a unique challenge. Since its inception, cardiopulmonary bypass (CPB) has required meticulous attention to maintaining adequate anticoagulation. New anticoagulants and alternative monitoring techniques present an opportunity to investigate potential advances in the area of anticoagulation for CPB. Hemostasis after CPB is still a vexing problem, and the addition of antiplatelet medication to the platelet defect already incurred during CPB has led to hemorrhagic complications in cardiac surgery. The two opposing processes of anticoagulation and hemostasis must be managed carefully and modified with respect to the patient's hematologic status and desired hemostatic outcome. Cardiac surgical patients consume a much larger fraction of perioperative blood transfusions than the percentage of the surgical population they represent. Thus, during CPB, careful attention must be paid to optimal anticoagulation, platelet quiescence, biocompatible circuitry and interventions, and to monitoring hemostasis. The multifactorial etiology of the CPB-induced hemostatic defect requires a multimodal approach to blood conservation and hemostasis monitoring, including heparin maintenance and sophisticated point-of-care hemostasis monitoring. Each technology has its own attributes and each may be suitable for different populations based upon the expected defects being measured. This article reviews the evidence supporting the use of point-of-care monitors in coagulation and hemostasis management in cardiac surgical patients.
Collapse
|
33
|
Skubas NJ, Despotis GJ. Optimal Management of Bleeding Complications After Cardiac Surgery. Semin Cardiothorac Vasc Anesth 2016. [DOI: 10.1053/scva.2001.26127] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Patients undergoing cardiac surgery with cardiopulmo nary bypass (CPB) are at increased risk for excessive perioperative blood loss requiring transfusion of blood products. Point-of-care evaluation of platelets, coagu lation factors, and fibrinogen can enable physicians to assess bleeding abnormalities rapidly. They also can facilitate the optimal administration of pharmacologic and transfusion-based therapy and allow physicians to identify patients with surgical bleeding. The ability to reduce the unnecessary use of blood products in this setting has important implications for emerging issues in blood inventory and blood costs. The ability to de crease operative time along with re-exploration rates has important consequences for health care costs in an increasingly managed health care environment. Copyright© 2001 by W.B. Saunders Company.
Collapse
Affiliation(s)
- Nikolaos J. Skubas
- Departments of Anesthesiology, Pathology, and Immunology, Washington University School of Medicine, St. Louis, MO
| | - George J. Despotis
- Departments of Anesthesiology, Pathology, and Immunology, Washington University School of Medicine, St. Louis, MO
| |
Collapse
|
34
|
Abstract
Cardiopulmonary bypass (CPB) is a nonphysiologic state that has many detrimental effects on a patient's hemostatic integrity. Exposure to the extracorporeal circuit and subsequent activation of the coagulation and fibrinolytic systems are factors that contribute to morbidity and mortality in cardiac surgical patients. These effects can be prevented in part or appropriately treated if practitioners understand the basic mecha nisms. This article reviews the effects of CPB on platelet function, the relationship of platelet function to post operative bleeding, the monitors available to measure platelet function, and the impact of antiplatelet therapy on bleeding in cardiac surgery.
Collapse
Affiliation(s)
- Shari Samson
- Department of Anesthesiology, Mount Sinai Medical Center, New York, NY
| | | |
Collapse
|
35
|
Affiliation(s)
- Christopher P. Price
- Department of Clinical Biochemistry, St Bartholomew's and the Royal London School of Medicine and Dentistry, Turner Street, London E1 2AD, UK
| |
Collapse
|
36
|
Deppe AC, Weber C, Zimmermann J, Kuhn EW, Slottosch I, Liakopoulos OJ, Choi YH, Wahlers T. Point-of-care thromboelastography/thromboelastometry-based coagulation management in cardiac surgery: a meta-analysis of 8332 patients. J Surg Res 2016; 203:424-33. [DOI: 10.1016/j.jss.2016.03.008] [Citation(s) in RCA: 133] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2015] [Revised: 02/07/2016] [Accepted: 03/02/2016] [Indexed: 11/27/2022]
|
37
|
Song JQ, Xuan LZ, Wu W, Huang JF, Zhong M. Low molecular weight heparin once versus twice for thromboprophylaxis following esophagectomy: a randomised, double-blind and placebo-controlled trial. J Thorac Dis 2015; 7:1158-64. [PMID: 26380731 PMCID: PMC4522502 DOI: 10.3978/j.issn.2072-1439.2015.06.15] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2015] [Accepted: 06/25/2015] [Indexed: 11/14/2022]
Abstract
BACKGROUND Venous thromboembolism (VTE) remained common complication following surgical resection of esophageal cancer. In this prospective randomized double-blind placebo-controlled trial (NCT01267305), we aim to compare the safety and efficacy between low molecular weight heparin (LMWH) once-daily (QD) and twice-daily (BID) for the prophylaxis of VTE following esophagectomy. METHODS During August 2012 to July 2013, patients underwent esophagectomy were randomly assigned to nadroparin calcium QD (4,100 AxaIU qd + placebo qd, group QD), or nadroparin calcium BID (4,100 AxaIU q12h, group BID) in the prophylaxis of VTE. All patients received thrombelastography (TEG) before and 0/24/48/72 hours after operation. Daily vascular ultrasound of lower extremities was followed during the first 7 postoperative days to confirm the suspected deep venous thrombosis (DVT). Cumulatively postoperative chest drainage at 72 hours after the surgery was collected to identify the difference in volume and red blood cell (RBC) counts between the two groups. Any bleeding events and thromboembolic events were also documented. RESULTS A total of 117 patients were enrolled in this study, and 111 eligible patients were randomly assigned (group QD: 55 patients; group BID: 56 patients). Patients' clinical features were close between the two groups. TEG analysis [R time, K time, alpha angel and maximum amplitude (MA)] before and instantly after operation showed nearly identical results. However, compared with group QD, all TEG measurements of 24/48/72 hours postoperatively showed significantly prolonged R time and K time, and decreased alpha angel in group BID. In ultrasound follow-ups, a total of four cases of DVT (four cases in group QD and no case in group BID) were found in this cohort (7.27% versus 0%, P=0.046), and one case of pulmonary embolism (PE) (in group QD) was observed. The incidence of VTE was lower in group BID (9.09% versus 0%, P=0.032). At 72 hours after surgery, the cumulative volume of chest drainage were close between these two groups (1,001.39±424.58 versus 1,133.61±513.93 mL, P=0.406). RBC counts in chest drainage were also identical between two groups [(2.56±1.98)×10(5) versus (2.71±4.67)×10(5), P=0.61]. No patient died due to VTE or bleeding events. CONCLUSIONS For the prophylaxis of VTE, BID LMWH provided more potent efficacy and equal safety when compared to QD LMWH in patients undergoing selective esophagectomy. Further study based on larger population is required to confirm these findings.
Collapse
Affiliation(s)
- Jie-Qiong Song
- Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Li-Zhen Xuan
- Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Wei Wu
- Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Jun-Feng Huang
- Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Ming Zhong
- Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| |
Collapse
|
38
|
Application of ROTEM to assess hypercoagulability in patients with lung cancer. Thromb Res 2015; 135:1075-80. [DOI: 10.1016/j.thromres.2015.03.021] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Revised: 02/09/2015] [Accepted: 03/12/2015] [Indexed: 12/21/2022]
|
39
|
Nates JL, Cattano D, Chelly JE, Doursout MF. Study of acute hemocoagulation changes in a porcine endotoxemic shock model using thrombelastography. Transl Res 2015; 165:549-57. [PMID: 25262937 DOI: 10.1016/j.trsl.2014.09.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 08/29/2014] [Accepted: 09/04/2014] [Indexed: 11/19/2022]
Abstract
Disseminated intravascular coagulation and fibrinolysis have been associated with lipopolysaccharide (LPS)-induced endotoxemic sepsis. It has been well established by point-of-care (POC) thrombelastography (TEG) that pigs have a hemocoagulation pathophysiology that resembles humans. We evaluated the use of TEG during the development of coagulation abnormalities in a porcine model of endotoxemia. After approval by the Animal Welfare Committee, pigs were instrumented to record hemodynamic variables. Ten days after surgical instrumentation, LPS (50 μg/kg) was infused intravenously over a period of 45 minutes in conscious animals. Hemodynamic parameters were recorded before and for 6 hours after LPS infusion was completed. Simultaneously, blood samples were analyzed using TEG to measure reaction time (R), clotting time (K), alpha angle (α), maximum amplitude (MA), coagulation index (CI), percent lysis at 30 minutes, and percent lysis at 60 minutes. LPS induced profound hemodynamic changes associated with the induced endotoxemia. Concomitantly, a progressive consumption coagulopathy characterized by significant increases in R and K and decreases in α, MA, and CI developed. The overall hemocoagulation profile of the 3 nonsurviving animals (27%) was significantly different than that of the survivors. Fibrinolysis was not detected during the 6-hour evaluation period. All stages of clot formation were affected as demonstrated by TEG (increased R and K, decreased α and MA). Our results suggest that TEG is a rapid method for assessing coagulation abnormalities in early stages of endotoxemia in pigs. TEG could have significant clinical applications as a rapid POC method in human patients with sepsis.
Collapse
Affiliation(s)
- Joseph L Nates
- Division of Anesthesiology and Critical Care, Department of Critical Care Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX.
| | - Davide Cattano
- Department of Anesthesiology, The University of Texas Medical School at Houston, Houston, TX
| | - Jacques E Chelly
- Department of Anesthesiology, The University of Pittsburgh School of Medicine, Pittsburgh, PA
| | | |
Collapse
|
40
|
Corredor C, Wasowicz M, Karkouti K, Sharma V. The role of point-of-care platelet function testing in predicting postoperative bleeding following cardiac surgery: a systematic review and meta-analysis. Anaesthesia 2015; 70:715-31. [PMID: 25916344 DOI: 10.1111/anae.13083] [Citation(s) in RCA: 83] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2015] [Indexed: 12/23/2022]
Abstract
This systematic review and meta-analysis appraises the utility of point-of-care platelet function tests for predicting blood loss and transfusion requirements in cardiac surgical patients, and analyses whether their use within a transfusion management algorithm is associated with improved patient outcomes. We included 30 observational studies incorporating 3044 patients in the qualitative assessment, and nine randomised controlled trials including 1057 patients in the meta-analysis. Platelet function tests demonstrated significant variability in their ability to predict blood loss and transfusion requirements. Their use within a blood transfusion algorithm demonstrated a reduction in blood loss at longest follow-up (mean difference -102.9 ml (95% CI -149.9 to -56.1 ml), p < 0.001), and transfusion of packed red cells (RR 0.86 (95% CI 0.78-0.94), p = 0.001) and fresh frozen plasma (RR 0.42 (95% CI 0.30-0.59), p < 0.001). Viscoelastic methods used in combination with other platelet function tests achieved greater reduction in blood loss (mean difference -111.8 ml (95% CI -174.9 to -49.1 ml), p = 0.0005) compared with their use alone (mean difference -90.6 ml (95% CI 166.1-15.0 ml), p = 0.02). We conclude that incorporation of point-of-care platelet function tests into transfusion management algorithms is associated with a reduction in blood loss and transfusion requirements in cardiac surgery patients.
Collapse
Affiliation(s)
- C Corredor
- Department of Anaesthesia, St. George's Hospital, London, UK
| | - M Wasowicz
- Department of Anesthesia and Pain Management, Toronto General Hospital, Toronto, Ontario, Canada
| | - K Karkouti
- Department of Anesthesia and Pain Management, Toronto General Hospital, Toronto, Ontario, Canada
| | - V Sharma
- Department of Anaesthesia, St. George's Hospital, London, UK
| |
Collapse
|
41
|
Geissler RG, Rotering H, Buddendick H, Franz D, Bunzemeier H, Roeder N, Kwiecien R, Sibrowski W, Scheld HH, Martens S, Schlenke P. Utilisation of blood components in cardiac surgery: a single-centre retrospective analysis with regard to diagnosis-related procedures. Transfus Med Hemother 2015; 42:75-82. [PMID: 26019702 DOI: 10.1159/000377691] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 12/05/2014] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND More blood components are required in cardiac surgery than in most other medical disciplines. The overall blood demand may increase as a function of the total number of cardiothoracic and vascular surgical interventions and their level of complexity, and also when considering the demographic ageing. Awareness has grown with respect to adverse events, such as transfusion-related immunomodulation by allogeneic blood supply, which can contribute to morbidity and mortality. Therefore, programmes of patient blood management (PBM) have been implemented to avoid unnecessary blood transfusions and to standardise the indication of blood transfusions more strictly with aim to improve patients' overall outcomes. METHODS A comprehensive retrospective analysis of the utilisation of blood components in the Department of Cardiac Surgery at the University Hospital of Münster (UKM) was performed over a 4-year period. Based on a medical reporting system of all medical disciplines, which was established as part of a PBM initiative, all transfused patients in cardiac surgery and their blood components were identified in a diagnosis- and medical procedure-related system, which allows the precise allocation of blood consumption to interventional procedures in cardiac surgery, such as coronary or valve surgery. RESULTS This retrospective single centre study included all in-patients in cardiac surgery at the UKM from 2009 to 2012, corresponding to a total of 1,405-1,644 cases per year. A blood supply was provided for 55.6-61.9% of the cardiac surgery patients, whereas approximately 9% of all in-patients at the UKM required blood transfusions. Most of the blood units were applied during cardiac valve surgery and during coronary surgery. Further surgical activities with considerable use of blood components included thoracic surgery, aortic surgery, heart transplantations and the use of artificial hearts. Under the measures of PBM in 2012 a noticeable decrease in the number of transfused cases was observed compared to the period from 2009 to 2011 before implementation of the PBM initiative (red blood cells p < 0.002; fresh frozen plasma p < 0.0006; platelets p < 0.00006). CONCLUSION Until now, cardiac surgery comes along with a significant blood supply. By using a case-related data evaluation programme, the consumption of each blood component can be linked to clinical performance groups and, if necessary, to individual patients. Based on the results obtained from this retrospective analysis, prospective studies are underway to begin conducting target / actual performance comparisons to better understand the individual decision-making by the attending physicians with respect to transfusions.
Collapse
Affiliation(s)
- Raoul Georg Geissler
- Institute for Transfusion Medicine and Transplantation Immunology, University Hospital of Münster, Münster, Germany
| | - Heinrich Rotering
- Department of Thoracic and Cardiovascular Surgery, University Hospital of Münster, Münster, Germany
| | - Hubert Buddendick
- DRG Research Group and Medical Management, University Hospital of Münster, Münster, Germany
| | - Dominik Franz
- DRG Research Group and Medical Management, University Hospital of Münster, Münster, Germany
| | - Holger Bunzemeier
- DRG Research Group and Medical Management, University Hospital of Münster, Münster, Germany
| | - Norbert Roeder
- DRG Research Group and Medical Management, University Hospital of Münster, Münster, Germany ; Board of Management, University Hospital of Münster, Münster, Germany
| | - Robert Kwiecien
- Institute for Biostatics and Clinical Research, University of Münster, Münster, Germany
| | - Walter Sibrowski
- Institute for Transfusion Medicine and Transplantation Immunology, University Hospital of Münster, Münster, Germany
| | - Hans H Scheld
- Department of Thoracic and Cardiovascular Surgery, University Hospital of Münster, Münster, Germany
| | - Sven Martens
- Department of Thoracic and Cardiovascular Surgery, University Hospital of Münster, Münster, Germany
| | - Peter Schlenke
- Institute for Transfusion Medicine and Transplantation Immunology, University Hospital of Münster, Münster, Germany ; Department of Blood Group Serology and Transfusion Medicine, Medical University Graz, Austria
| |
Collapse
|
42
|
Theusinger OM, Stein P, Levy JH. Point of care and factor concentrate-based coagulation algorithms. Transfus Med Hemother 2015; 42:115-21. [PMID: 26019707 DOI: 10.1159/000381320] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 03/03/2015] [Indexed: 11/19/2022] Open
Abstract
In the last years it has become evident that the use of blood products should be reduced whenever possible. There is increasing evidence regarding serious adverse events, including higher mortality and morbidity, related to transfusions. The use of point of care (POC) devices integrated in algorithms is one of the important mechanisms to limit blood product exposure. Any type of algorithm, especially the POC-based ones, allows goal-directed transfusions of blood products and even better targeted factor concentrate substitutions. Different types of algorithms in different surgical settings (cardiac surgery, trauma, liver surgery etc.) have been established with growing interest in their use as they offer objective therapy for management and reduction of blood product use. The use of POC devices with evidence-based algorithms is important in the bleeding patient independent of its origin (traumatic vs. surgical). The use of factor concentrates compared to the classical blood products can be cost-saving, beneficial for the patient, and in agreement with the WHO-requested standard of care. The empiric and uncontrolled use of blood products such as fresh frozen plasma, red blood cells, and platelets without POC monitoring should no longer be followed with regard to actual evidence in literature. Furthermore, the use of factor concentrates may provide better outcomes and potential for cost saving.
Collapse
Affiliation(s)
- Oliver M Theusinger
- Institute of Anesthesiology, University and University Hospital of Zurich, Zurich, Switzerland
| | - Philipp Stein
- Institute of Anesthesiology, University and University Hospital of Zurich, Zurich, Switzerland
| | - Jerrold H Levy
- Cardiothoracic ICU, Duke University School of Medicine, Durham, NC, USA
| |
Collapse
|
43
|
Judith RM, Fisher JK, Spero RC, Fiser BL, Turner A, Oberhardt B, Taylor RM, Falvo MR, Superfine R. Micro-elastometry on whole blood clots using actuated surface-attached posts (ASAPs). LAB ON A CHIP 2015; 15:1385-93. [PMID: 25592158 PMCID: PMC4545258 DOI: 10.1039/c4lc01478b] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We present a novel technology for microfluidic elastometry and demonstrate its ability to measure stiffness of blood clots as they form. A disposable micro-capillary strip draws small volumes (20 μL) of whole blood into a chamber containing a surface-mounted micropost array. The posts are magnetically actuated, thereby applying a shear stress to the blood clot. The posts' response to magnetic field changes as the blood clot forms; this response is measured by optical transmission. We show that a quasi-static model correctly predicts the torque applied to the microposts. We experimentally validate the ability of the system to measure clot stiffness by correlating our system with a commercial thromboelastograph. We conclude that actuated surface-attached post (ASAP) technology addresses a clinical need for point-of-care and small-volume elastic haemostatic assays.
Collapse
Affiliation(s)
- Robert M Judith
- University of North Carolina at Chapel Hill Department of Physics & Astronomy, Chapel Hill, NC, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Mallett SV, Armstrong M. Point-of-care monitoring of haemostasis. Anaesthesia 2014; 70 Suppl 1:73-7, e25-6. [DOI: 10.1111/anae.12909] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/01/2014] [Indexed: 12/18/2022]
Affiliation(s)
- S. V. Mallett
- Department of Anaesthesia; Royal Free London NHS Trust; London UK
| | - M. Armstrong
- Department of Anaesthesia; Royal Free London NHS Trust; London UK
| |
Collapse
|
45
|
Anderson L, Quasim I, Steven M, Moise SF, Shelley B, Schraag S, Sinclair A. Interoperator and Intraoperator Variability of Whole Blood Coagulation Assays: A Comparison of Thromboelastography and Rotational Thromboelastometry. J Cardiothorac Vasc Anesth 2014; 28:1550-7. [DOI: 10.1053/j.jvca.2014.05.023] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2014] [Indexed: 11/11/2022]
|
46
|
Bogert JN, Harvin JA, Cotton BA. Damage Control Resuscitation. J Intensive Care Med 2014; 31:177-86. [PMID: 25385695 DOI: 10.1177/0885066614558018] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Accepted: 09/09/2014] [Indexed: 01/26/2023]
Abstract
Resuscitation of the hemorrhaging patient has undergone significant changes in the last decade resulting in the concept of damage control resuscitation (DCR). Hemostatic resuscitation aims to address the physiologic derangements found in the hemorrhaging patient, namely coagulopathy, acidosis, and hypothermia. Strategies to achieve this are permissive hypotension, high ratio of plasma and platelet transfusion to packed red blood cell transfusion, and limitation of crystalloid administration. Damage control surgery aims for early hemorrhage control and minimizing operative time by delaying definitive repair until the patient's physiologic status has normalized. Together these strategies constitute DCR and have led to improved outcomes for hemorrhaging patients over the last 2 decades. Recently, DCR has been augmented by both pharmacologic and laboratory adjuncts to improve the care of the hemorrhaging patient. These include thrombelastography as a detailed measure of the clotting cascade, tranexamic acid as an antifibrinolytic, and the procoagulant activated factor VII. In this review, we discuss the strategies that makeup DCR, their adjuncts, and how they fit into the care of the hemorrhaging patient.
Collapse
Affiliation(s)
- James N Bogert
- Department of Surgery, University of Texas Medical School at Houston, Houston, TX, USA
| | - John A Harvin
- Department of Surgery, University of Texas Medical School at Houston, Houston, TX, USA
| | - Bryan A Cotton
- Department of Surgery, University of Texas Medical School at Houston, Houston, TX, USA
| |
Collapse
|
47
|
Comparison of three point-of-care testing devices to detect hemostatic changes in adult elective cardiac surgery: a prospective observational study. BMC Anesthesiol 2014; 14:80. [PMID: 25276093 PMCID: PMC4179787 DOI: 10.1186/1471-2253-14-80] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Accepted: 07/21/2014] [Indexed: 11/19/2022] Open
Abstract
Background Bleeding complications in cardiac surgery may lead to increased morbidity and mortality. Traditional blood coagulation tests are not always suitable to detect rapid changes in the patient's coagulation status. Point-of-care instruments such as the TEG (thromboelastograph) and RoTEM (thromboelastometer) have been shown to be useful as a guide for the clinician in the choice of blood products and they may lead to a reduction in the need for blood transfusion, contributing to better patient blood management. Methods The purpose of this study was to evaluate the ability of the TEG, RoTEM and Sonoclot instruments to detect changes in hemostasis in elective cardiac surgery with cardiopulmonary bypass and to investigate possible correlations between variables from these three instruments and routine hematological coagulation tests. Blood samples from thirty-five adult patients were drawn before and after surgery and analyzed in TEG, RoTEM, Sonoclot and routine coagulation tests. Data were compared using repeated measures analysis of variance and Pearson's test for linear correlation. Results We found significant changes for all TEG variables after surgery, for three of the RoTEM variables, and for one variable from the Sonoclot. There were significant correlations postoperatively between plasma fibrinogen levels and variables from the three instruments. Conclusions TEG and RoTEM may be used to detect changes in hemostasis following cardiac surgery with CPB. Sonoclot seems to be less suitable to detect such changes. Variables from the three instruments correlated with plasma fibrinogen and could be used to monitor treatment with fibrinogen concentrate.
Collapse
|
48
|
Petricevic M, Biocina B, Milicic D, Svetina L, Boban M, Lekić A, Konosic S, Milosevic M, Gasparovic H. Activated coagulation time vs. intrinsically activated modified rotational thromboelastometry in assessment of hemostatic disturbances and blood loss after protamine administration in elective cardiac surgery: analysis from the clinical trial (NCT01281397). J Cardiothorac Surg 2014; 9:129. [PMID: 25231271 PMCID: PMC4283124 DOI: 10.1186/1749-8090-9-129] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 03/11/2014] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Excessive bleeding after cardiopulmonary bypass (CPB) is risk factor for adverse outcomes after elective cardiac surgery (ECS). Although many different point-of-care devices to diagnose hemostatic disturbances after CPB are available, the best test is still unclear. The study aim was to compare the accuracy of hemostatic disorder detection between two point-of-care devices. METHODS We enrolled 148 patients (105 male and 43 female) undergoing ECS in a prospective observational study. Rotational thromboelastometry (TEM, with InTEM test), and Activated coagulation time (ACT) measurement were performed 15 min after protamine administration. The cohort group was divided into two subgroups according to occurrence of excessive postoperative bleeding. Endpoints were defined in two ways: as total amount of chest tube output (CTO) and blood product transfusion requirements. RESULTS Total amount of CTO value of 1507,50 mL presented 75th percentile of distribution, thus cut-off value for bleeder category. InTEM parameters, but not ACT, correlated significantly with CTO. InTEM parameters with the strongest correlation to CTO were tested for accuracy in predicting excessive postoperative bleeding using ROC analysis. InTEM A 10 value of 38 mm, InTEM A 20 value of 49 mm and InTEM A 30 value of 51 mm delineated bleeding tendency. Patients with total amount of CTO exceeding 75th percentile were more frequently transfused with fresh frozen plasma (51.4% vs. 9.9%, p < 0.001), fibrinogen concentrate (21.6% vs. 2.7%, p = 0.001) and platelet concentrate (13.5% vs. 0.9%, p = 0.004). CONCLUSION Our study showed that InTEM test, but not ACT is useful in prediction of bleeding tendency after protamine administration following weaning from CPB. InTEM test could be used as a first line test in screening of possible hemostatic disorder following protamine administration.
Collapse
Affiliation(s)
- Mate Petricevic
- />Department of Cardiac Surgery, University Hospital Center Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Bojan Biocina
- />Department of Cardiac Surgery, University Hospital Center Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Davor Milicic
- />University of Zagreb School of Medicine, Department of Cardiovascular Diseases, University Hospital Center Zagreb, Zagreb, Croatia
| | - Lucija Svetina
- />Department of Cardiac Surgery, University Hospital Center Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Marko Boban
- />Department of Cardiology, University Hospital “Thalassotherapia Opatija”, Medical School University of Rijeka and Osijek, Opatija, Croatia
| | - Ante Lekić
- />Department of Cardiac Surgery, University Hospital Center Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Sanja Konosic
- />University of Zagreb School of Medicine, Department of Anesthesiology, University Hospital Center Zagreb, Zagreb, Croatia
| | - Milan Milosevic
- />Andrija Stampar School of Public Health, University of Zagreb School of Medicine, Zagreb, Croatia
| | - Hrvoje Gasparovic
- />Department of Cardiac Surgery, University Hospital Center Zagreb, University of Zagreb School of Medicine, Zagreb, Croatia
| |
Collapse
|
49
|
Karon BS. Why is everyone so excited about thromboelastrography (TEG)? Clin Chim Acta 2014; 436:143-8. [DOI: 10.1016/j.cca.2014.05.013] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 05/14/2014] [Accepted: 05/15/2014] [Indexed: 11/27/2022]
|
50
|
Alamo JM, León A, Mellado P, Bernal C, Marín LM, Cepeda C, Suárez G, Serrano J, Padillo J, Gómez MÁ. Is "intra-operating room" thromboelastometry useful in liver transplantation? A case-control study in 303 patients. Transplant Proc 2014; 45:3637-9. [PMID: 24314981 DOI: 10.1016/j.transproceed.2013.11.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Coagulation monitoring during liver transplantation (LT) is, even today, fundamental to reduce blood loss during surgery. Thromboelastometry (TEM) is a proven technique for controlling the various parameters that influence coagulation. However, there are no studies linking "intra-operating room" TEM (orTEM) with LT outcomes. We describe a case-control study in 303 liver graft recipients analyzing variables associated with operative complications and long-term LT outcomes. The results showed that orTEM reduced the use of blood products in patients with Model for End-Stage Liver Disease scores of ≥ 21, retransplantation, and high surgical difficulty and important intraoperative bleeding. In addition, results in survival and postoperative complications were better when orTEM was used. In conclusion, we confirm that use of orTEM is associated with less use of blood products and a lower rate of complications after LT.
Collapse
Affiliation(s)
- J-M Alamo
- Liver Transplant Unit, Sevilla, Spain.
| | | | | | | | | | | | | | | | | | | |
Collapse
|