1
|
Scott JW, Ng KCG, Liddle AD, Jeffers JRT. Method for accurate removal of trabecular bone samples from a curved articulating surface of the distal femur. Clin Biomech (Bristol, Avon) 2024; 115:106240. [PMID: 38615548 DOI: 10.1016/j.clinbiomech.2024.106240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 03/06/2024] [Accepted: 04/09/2024] [Indexed: 04/16/2024]
Abstract
BACKGROUND Knowing the mechanical properties of trabecular bone is critical for many branches of orthopaedic research. Trabecular bone is anisotropic and the principal trabecular direction is usually aligned with the load it transmits. It is therefore critical that the mechanical properties are measured as close as possible to this direction, which is often perpendicular to a curved articulating surface. METHODS This study presents a method to extract trabecular bone cores perpendicular to a curved articulating surface of the distal femur. Cutting guides were generated from computed tomography scans of 12 human distal femora and a series of cutting tools were used to release cylindrical bone cores from the femora. The bone cores were then measured to identify the angle between the bone core axis and the principal trabecular axis. FINDINGS The method yielded an 83% success rate in core extraction over 10 core locations per distal femur specimen. In the condyles, 97% of extracted cores were aligned with the principal trabecular direction. INTERPRETATION This method is a reliable way of extracting trabecular bone specimens perpendicular to a curved articular surface and could be useful across the field of orthopaedic research.
Collapse
Affiliation(s)
- James W Scott
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, United Kingdom.
| | - K C Geoffrey Ng
- Department of Medical Biophysics, Western University, Canada; Department of Medical Imaging, Western University, Canada; Department of Surgery, Western University, Canada; Robarts Research Institute, Western University, Canada; MSk Lab, Department of Surgery and Cancer, Imperial College London, United Kingdom
| | - Alexander D Liddle
- MSk Lab, Department of Surgery and Cancer, Imperial College London, United Kingdom
| | - Jonathan R T Jeffers
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, United Kingdom
| |
Collapse
|
2
|
Berni M, Marchiori G, Baleani M, Giavaresi G, Lopomo NF. Biomechanics of the Human Osteochondral Unit: A Systematic Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1698. [PMID: 38612211 PMCID: PMC11012636 DOI: 10.3390/ma17071698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 03/17/2024] [Accepted: 03/26/2024] [Indexed: 04/14/2024]
Abstract
The damping system ensured by the osteochondral (OC) unit is essential to deploy the forces generated within load-bearing joints during locomotion, allowing furthermore low-friction sliding motion between bone segments. The OC unit is a multi-layer structure including articular cartilage, as well as subchondral and trabecular bone. The interplay between the OC tissues is essential in maintaining the joint functionality; altered loading patterns can trigger biological processes that could lead to degenerative joint diseases like osteoarthritis. Currently, no effective treatments are available to avoid degeneration beyond tissues' recovery capabilities. A thorough comprehension on the mechanical behaviour of the OC unit is essential to (i) soundly elucidate its overall response to intra-articular loads for developing diagnostic tools capable of detecting non-physiological strain levels, (ii) properly evaluate the efficacy of innovative treatments in restoring physiological strain levels, and (iii) optimize regenerative medicine approaches as potential and less-invasive alternatives to arthroplasty when irreversible damage has occurred. Therefore, the leading aim of this review was to provide an overview of the state-of-the-art-up to 2022-about the mechanical behaviour of the OC unit. A systematic search is performed, according to PRISMA standards, by focusing on studies that experimentally assess the human lower-limb joints' OC tissues. A multi-criteria decision-making method is proposed to quantitatively evaluate eligible studies, in order to highlight only the insights retrieved through sound and robust approaches. This review revealed that studies on human lower limbs are focusing on the knee and articular cartilage, while hip and trabecular bone studies are declining, and the ankle and subchondral bone are poorly investigated. Compression and indentation are the most common experimental techniques studying the mechanical behaviour of the OC tissues, with indentation also being able to provide information at the micro- and nanoscales. While a certain comparability among studies was highlighted, none of the identified testing protocols are currently recognised as standard for any of the OC tissues. The fibril-network-reinforced poro-viscoelastic constitutive model has become common for describing the response of the articular cartilage, while the models describing the mechanical behaviour of mineralised tissues are usually simpler (i.e., linear elastic, elasto-plastic). Most advanced studies have tested and modelled multiple tissues of the same OC unit but have done so individually rather than through integrated approaches. Therefore, efforts should be made in simultaneously evaluating the comprehensive response of the OC unit to intra-articular loads and the interplay between the OC tissues. In this regard, a multidisciplinary approach combining complementary techniques, e.g., full-field imaging, mechanical testing, and computational approaches, should be implemented and validated. Furthermore, the next challenge entails transferring this assessment to a non-invasive approach, allowing its application in vivo, in order to increase its diagnostic and prognostic potential.
Collapse
Affiliation(s)
- Matteo Berni
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; (M.B.); (M.B.)
| | - Gregorio Marchiori
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | - Massimiliano Baleani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; (M.B.); (M.B.)
| | - Gianluca Giavaresi
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | | |
Collapse
|
3
|
Hijazi KM, Dixon SJ, Armstrong JE, Rizkalla AS. Titanium Alloy Implants with Lattice Structures for Mandibular Reconstruction. MATERIALS (BASEL, SWITZERLAND) 2023; 17:140. [PMID: 38203994 PMCID: PMC10779528 DOI: 10.3390/ma17010140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/30/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024]
Abstract
In recent years, the field of mandibular reconstruction has made great strides in terms of hardware innovations and their clinical applications. There has been considerable interest in using computer-aided design, finite element modelling, and additive manufacturing techniques to build patient-specific surgical implants. Moreover, lattice implants can mimic mandibular bone's mechanical and structural properties. This article reviews current approaches for mandibular reconstruction, their applications, and their drawbacks. Then, we discuss the potential of mandibular devices with lattice structures, their development and applications, and the challenges for their use in clinical settings.
Collapse
Affiliation(s)
- Khaled M. Hijazi
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
| | - S. Jeffrey Dixon
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON N6A 5C1, Canada
| | - Jerrold E. Armstrong
- Division of Oral and Maxillofacial Surgery, Department of Otolaryngology Head and Neck Surgery, Henry Ford Hospital, Detroit, MI 48202, USA
| | - Amin S. Rizkalla
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON N6A 5C1, Canada
- Chemical and Biochemical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 5B9, Canada
| |
Collapse
|
4
|
Moshage SG, McCoy AM, Kersh ME. Elastic Modulus and Its Relation to Apparent Mineral Density in Juvenile Equine Bones of the Lower Limb. J Biomech Eng 2023; 145:081001. [PMID: 37144881 DOI: 10.1115/1.4062488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 05/01/2023] [Indexed: 05/06/2023]
Abstract
Density-modulus relationships are necessary to develop finite element models of bones that may be used to evaluate local tissue response to different physical activities. It is unknown if juvenile equine trabecular bone may be described by the same density-modulus as adult equine bone, and how the density-modulus relationship varies with anatomical location and loading direction. To answer these questions, trabecular bone cores from the third metacarpal (MC3) and proximal phalanx (P1) bones of juvenile horses (age <1 yr) were machined in the longitudinal (n = 134) and transverse (n = 90) directions and mechanically tested in compression. Elastic modulus was related to apparent computed tomography density of each sample using power law regressions. We found that density-modulus relationships for juvenile equine trabecular bone were significantly different for each anatomical location (MC3 versus P1) and orientation (longitudinal versus transverse). Use of the incorrect density-modulus relationship resulted in increased root mean squared percent error of the modulus prediction by 8-17%. When our juvenile density-modulus relationship was compared to one of an equivalent location in adult horses, the adult relationship resulted in an approximately 80% increase in error of the modulus prediction. Moving forward, more accurate models of young bone can be developed and used to evaluate potential exercise regimens designed to encourage bone adaptation.
Collapse
Affiliation(s)
- Sara G Moshage
- Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801
| | - Annette M McCoy
- Department of Veterinary Clinical Medicine, University of Illinois Urbana-Champaign, Urbana, IL 61801
| | - Mariana E Kersh
- Department of Mechanical Science and Engineering, Beckman Institute for Advanced Science and Technology, Carle Illinois College of Medicine, University of Illinois Urbana-Champaign,, Urbana, IL 61801
| |
Collapse
|
5
|
Balestri W, Hickman GJ, Morris RH, Hunt JA, Reinwald Y. Triphasic 3D In Vitro Model of Bone-Tendon-Muscle Interfaces to Study Their Regeneration. Cells 2023; 12:313. [PMID: 36672248 PMCID: PMC9856925 DOI: 10.3390/cells12020313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/02/2023] [Accepted: 01/10/2023] [Indexed: 01/18/2023] Open
Abstract
The transition areas between different tissues, known as tissue interfaces, have limited ability to regenerate after damage, which can lead to incomplete healing. Previous studies focussed on single interfaces, most commonly bone-tendon and bone-cartilage interfaces. Herein, we develop a 3D in vitro model to study the regeneration of the bone-tendon-muscle interface. The 3D model was prepared from collagen and agarose, with different concentrations of hydroxyapatite to graduate the tissues from bones to muscles, resulting in a stiffness gradient. This graduated structure was fabricated using indirect 3D printing to provide biologically relevant surface topographies. MG-63, human dermal fibroblasts, and Sket.4U cells were found suitable cell models for bones, tendons, and muscles, respectively. The biphasic and triphasic hydrogels composing the 3D model were shown to be suitable for cell growth. Cells were co-cultured on the 3D model for over 21 days before assessing cell proliferation, metabolic activity, viability, cytotoxicity, tissue-specific markers, and matrix deposition to determine interface formations. The studies were conducted in a newly developed growth chamber that allowed cell communication while the cell culture media was compartmentalised. The 3D model promoted cell viability, tissue-specific marker expression, and new matrix deposition over 21 days, thereby showing promise for the development of new interfaces.
Collapse
Affiliation(s)
- Wendy Balestri
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - Graham J. Hickman
- Imaging Suite, School of Science & Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - Robert H. Morris
- Department of Physics and Mathematics, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - John A. Hunt
- Medical Technologies and Advanced Materials, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
- College of Biomedical Engineering, China Medical University, Taichung 40402, Taiwan
| | - Yvonne Reinwald
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
| |
Collapse
|
6
|
Alaña M, Lopez-Arancibia A, Ghouse S, Rodriguez-Florez N, Ruiz de Galarreta S. Additively manufactured lattice structures with controlled transverse isotropy for orthopedic porous implants. Comput Biol Med 2022; 150:105761. [PMID: 36126355 DOI: 10.1016/j.compbiomed.2022.105761] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/31/2022] [Accepted: 06/18/2022] [Indexed: 11/26/2022]
Abstract
Additively manufactured lattice structures enable the design of tissue scaffolds with tailored mechanical properties, which can be implemented in porous biomaterials. The adaptation of bone to physiological loads results in anisotropic bone tissue properties which are optimized for site-specific loads; therefore, some bone sites are stiffer and stronger along the principal load direction compared to other orientations. In this work, a semi-analytical model was developed for the design of transversely isotropic lattice structures that can mimic the anisotropy characteristics of different types of bone tissue. Several design possibilities were explored, and a particular unit cell, which was best suited for additive manufacturing was further analyzed. The design of the unit cell was parameterized and in-silico analysis was performed via Finite Element Analysis. The structures were manufactured additively in metal and tested under compressive loads in different orientations. Finite element analysis showed good correlation with the semi-analytical model, especially for elastic constants with low relative densities. The anisotropy measured experimentally showed a variable accuracy, highlighting the deviations from designs to additively manufactured parts. Overall, the proposed model enables to exploit the anisotropy of lattice structures to design lighter scaffolds with higher porosity and increased permeability by aligning the scaffold with the principal direction of the load.
Collapse
Affiliation(s)
- Markel Alaña
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018 San Sebastian, Spain.
| | - Aitziber Lopez-Arancibia
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018 San Sebastian, Spain
| | - Shaaz Ghouse
- Department of Mechanical Engineering, Imperial College London, South Kensington London SW7 2AZ, UK
| | - Naiara Rodriguez-Florez
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018 San Sebastian, Spain; IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
| | - Sergio Ruiz de Galarreta
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018 San Sebastian, Spain
| |
Collapse
|
7
|
Metzner F, Neupetsch C, Carabello A, Pietsch M, Wendler T, Drossel WG. Biomechanical validation of additively manufactured artificial femoral bones. BMC Biomed Eng 2022; 4:6. [PMID: 35927720 PMCID: PMC9354338 DOI: 10.1186/s42490-022-00063-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 07/21/2022] [Indexed: 01/15/2023] Open
Abstract
Replicating the mechanical behavior of human bones, especially cancellous bone tissue, is challenging. Typically, conventional bone models primarily consist of polyurethane foam surrounded by a solid shell. Although nearly isotropic foam components have mechanical properties similar to cancellous bone, they do not represent the anisotropy and inhomogeneity of bone architecture. To consider the architecture of bone, models were developed whose core was additively manufactured based on CT data. This core was subsequently coated with glass fiber composite. Specimens consisting of a gyroid-structure were fabricated using fused filament fabrication (FFF) techniques from different materials and various filler levels. Subsequent compression tests showed good accordance between the mechanical behavior of the printed specimens and human bone. The unidirectional fiberglass composite showed higher strength and stiffness than human cortical bone in 3-point bending tests, with comparable material behaviors being observed. During biomechanical investigation of the entire assembly, femoral prosthetic stems were inserted into both artificial and human bones under controlled conditions, while recording occurring forces and strains. All of the artificial prototypes, made of different materials, showed analogous behavior to human bone. In conclusion, it was shown that low-cost FFF technique can be used to generate valid bone models and selectively modify their properties by changing the infill.
Collapse
Affiliation(s)
- F. Metzner
- grid.9647.c0000 0004 7669 9786ZESBO Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103 Leipzig, Germany ,grid.9647.c0000 0004 7669 9786Department of Orthopaedics, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany
| | - C. Neupetsch
- grid.9647.c0000 0004 7669 9786Department of Orthopaedics, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany ,grid.461651.10000 0004 0574 2038Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany ,grid.6810.f0000 0001 2294 5505Professorship of Adaptronics and Lightweight Design, Chemnitz Universtiy of Technology, Chemnitz, Germany
| | - A. Carabello
- grid.461651.10000 0004 0574 2038Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany ,grid.6810.f0000 0001 2294 5505Professorship of Adaptronics and Lightweight Design, Chemnitz Universtiy of Technology, Chemnitz, Germany
| | - M. Pietsch
- grid.461651.10000 0004 0574 2038Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany
| | - T. Wendler
- grid.9647.c0000 0004 7669 9786ZESBO Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103 Leipzig, Germany ,grid.9647.c0000 0004 7669 9786Department of Orthopaedics, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany
| | - W.-G. Drossel
- grid.461651.10000 0004 0574 2038Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany ,grid.6810.f0000 0001 2294 5505Professorship of Adaptronics and Lightweight Design, Chemnitz Universtiy of Technology, Chemnitz, Germany
| |
Collapse
|
8
|
Characterizing the Mechanical Behavior of Bone and Bone Surrogates in Compression Using pQCT. MATERIALS 2022; 15:ma15145065. [PMID: 35888531 PMCID: PMC9320168 DOI: 10.3390/ma15145065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 07/12/2022] [Accepted: 07/18/2022] [Indexed: 01/27/2023]
Abstract
Many axial and appendicular skeleton bones are subjected to repetitive loading during daily activities. Until recently, the structural analysis of fractures has been limited to 2D sections, and the dynamic assessment of fracture progression has not been possible. The structural failure was analyzed using step-wise micro-compression combined with time-lapsed micro-computed tomographic imaging. The structural failure was investigated in four different sample materials (two different bone surrogates, lumbar vertebral bodies from bovine and red deer). The samples were loaded in different force steps based on uniaxial compression tests. The micro-tomography images were used to create three-dimensional models from which various parameters were calculated that provide information about the structure and density of the samples. By superimposing two 3D images and calculating the different surfaces, it was possible to precisely analyze which trabeculae failed in which area and under which load. According to the current state of the art, bone mineral density is usually used as a value for bone quality, but the question can be raised as to whether other values such as trabecular structure, damage accumulation, and bone mineralization can predict structural competence better than bone mineral density alone.
Collapse
|
9
|
Zhao G, Wang X, Liu D, Wu K, Zhao J, Fei W. A biomechanical study of ligament tethers strengthening for the prevention of proximal junctional kyphosis after posterior long-segment spinal fusion. Clin Biomech (Bristol, Avon) 2022; 94:105621. [PMID: 35299117 DOI: 10.1016/j.clinbiomech.2022.105621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 03/02/2022] [Accepted: 03/08/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Proximal junctional kyphosis is a known complication of posterior long-segment thoracolumbar fusion. Here, the biomechanical effectiveness of ligament tethers strengthening and vertebral body augmentation, in proximal junctional kyphosis prevention was explored using the finite element analysis. METHODS Based on a validated model of T1-L5 with the pedicle screw system instrumented T8-L5, strengthening models with different strategies were created to assess the range of motion in proximal vertebrae, vertebrae stress, pedicle screw stress, and pressure on intervertebral discs during extension, flexion, lateral bending, and axial rotation motions. Strengthening strategies included two- and three-level posterior ligament tethers (TE-T7-T9 and TE-T6-T9), and tethers with T7 &T8 vertebral body augmentation (TECE-T7-T9 and TECE-T6-T9). FINDINGS Compared to the spinal fusion model, the ligament tethers strengthening significantly reduced the flexion-extension range of motion difference among the proximal vertebrae. During the flexion-extension motion, the T8 vertebra stresses in the TE-T7-T9, TE-T6-T9, TECE-T7-T9, and TECE-T6-T9 models were distinctively reduced, the values decreased by 26.8%, 28.3%, 28.8%, and 9.6%, respectively, during flexion, and by 21.9%, 35.2%, 23%, and 18.6%, respectively, during extension. In the strengthening models, the maximum stresses on the T7/T8 intervertebral disc in the TE-T6-T9 model were reduced by 13.8% during flexion and by 14.7% during extension. INTERPRETATION Based on our results, the ligament strengthening configuration of the three-level posterior tethers produced a more gradual transition in range of motion, vertebrae stresses, and intervertebral discs stress between the fused and non-fused segments, especially during flexion-extension, which may significantly decrease the proximal junctional kyphosis biomechanical risk.
Collapse
Affiliation(s)
- Gaiping Zhao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
| | - Xiaoyu Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Dongqing Liu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Kunneng Wu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Jian Zhao
- Department of Orthopedics, Western Theater General Hospital, Chengdu, China
| | - Wang Fei
- Chang-Hai Hospital, The Second Military Medical University, Shanghai, China
| |
Collapse
|
10
|
Noonan AM, Oxland TR, Brown SHM. Investigating the active contractile function of the rat paraspinal muscles reveals unique cross-bridge kinetics in the multifidus. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2022; 31:783-791. [PMID: 35089421 DOI: 10.1007/s00586-022-07120-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 11/17/2021] [Accepted: 01/13/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE Various aspects of paraspinal muscle anatomy, biology, and histology have been studied; however, information on paraspinal muscle contractile function is almost nonexistent, thus hindering functional interpretation of these muscles in healthy individuals and those with low back disorders. The aim of this study was to measure and compare the contractile function and force-sarcomere length properties of muscle fibers from the multifidus (MULT) and erector spinae (ES) as well as a commonly studied lower limb muscle (Extensor digitorum longus (EDL)) in the rat. METHODS Single muscle fibers (n = 77 total from 6 animals) were isolated from each of the muscles and tested to determine their active contractile function; all fibers used in the analyses were type IIB. RESULTS There were no significant differences between muscles for specific force (sFo) (p = 0.11), active modulus (p = 0.63), average optimal sarcomere length (p = 0.27) or unloaded shortening velocity (Vo) (p = 0.69). However, there was a significant difference in the rate of force redevelopment (ktr) between muscles (p = < 0.0001), with MULT being significantly faster than both the EDL (p = < 0.0001) and ES (p = 0.0001) and no difference between the EDL and ES (p = 0.41). CONCLUSIONS This finding suggests that multifidus has faster cross-bridge turnover kinetics when compared to other muscles (ES and EDL) when matched for fiber type. Whether the faster cross-bridge kinetics translate to a functionally significant difference in whole muscle performance needs to be studied further.
Collapse
Affiliation(s)
- Alex M Noonan
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON, Canada
| | - Thomas R Oxland
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
- International Collaboration on Repair Discoveries (ICORD), The University of British Columbia, Vancouver, Canada
- Department of Mechanical Engineering, The University of British Columbia, Vancouver, Canada
| | - Stephen H M Brown
- Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON, Canada.
| |
Collapse
|
11
|
Öhman‐Mägi C, Holub O, Wu D, Hall RM, Persson C. Density and mechanical properties of vertebral trabecular bone-A review. JOR Spine 2021; 4:e1176. [PMID: 35005442 PMCID: PMC8717096 DOI: 10.1002/jsp2.1176] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 10/14/2021] [Accepted: 10/20/2021] [Indexed: 11/16/2022] Open
Abstract
Being able to predict the mechanical properties of vertebrae in patients with osteoporosis and other relevant pathologies is essential to prevent fractures and to develop the most favorable fracture treatments. Furthermore, a reliable prediction is important for developing more patient- and pathology-specific biomaterials. A plethora of studies correlating bone density to mechanical properties has been reported; however, the results are variable, due to a variety of factors, including anatomical site and methodological differences. The aim of this study was to provide a comprehensive literature review on density and mechanical properties of human vertebral trabecular bone as well as relationships found between these properties. A literature search was performed to include studies, which investigated mechanical properties and bone density of trabecular bone. Only studies on vertebral trabecular bone tissue, reporting bone density or mechanical properties, were kept. A large variation in reported vertebral trabecular bone densities, mechanical properties, and relationships between the two was found, as exemplified by values varying between 0.09 and 0.35 g/cm3 for the wet apparent density and from 0.1 to 976 MPa for the elastic modulus. The differences were found to reflect variations in experimental and analytical processes that had been used, including testing protocol and specimen geometry. The variability in the data decreased in studies where bone tissue testing occurred in a standardized manner (eg, the reported differences in average elastic modulus decreased from 400% to 10%). It is important to take this variability into account when analyzing the predictions found in the literature, for example, to calculate fracture risk, and it is recommended to use the models suggested in the present review to reduce data variability.
Collapse
Affiliation(s)
- Caroline Öhman‐Mägi
- Department of Materials Science and EngineeringUppsala UniversityUppsalaSweden
| | - Ondrej Holub
- School of Mechanical EngineeringUniversity of LeedsLeedsUK
| | - Dan Wu
- Department of Materials Science and EngineeringUppsala UniversityUppsalaSweden
| | | | - Cecilia Persson
- Department of Materials Science and EngineeringUppsala UniversityUppsalaSweden
| |
Collapse
|
12
|
Gao Y, Lu F, Wang S, Sun L, Leng H, Huo B. Effect of long-term cyclic compression loading on the structural evolution of trabecular bone. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2021. [DOI: 10.1016/j.medntd.2021.100099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
13
|
Determination of anisotropic elastic parameters from morphological parameters of cancellous bone for osteoporotic lumbar spine. Med Biol Eng Comput 2021; 60:263-278. [PMID: 34843037 PMCID: PMC8724118 DOI: 10.1007/s11517-021-02465-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 10/25/2021] [Indexed: 12/03/2022]
Abstract
In biomechanics, large finite element models with macroscopic representation of several bones or joints are necessary to analyze implant failure mechanisms. In order to handle large simulation models of human bone, it is crucial to homogenize the trabecular structure regarding the mechanical behavior without losing information about the realistic material properties. Accordingly, morphology and fabric measurements of 60 vertebral cancellous bone samples from three osteoporotic lumbar spines were performed on the basis of X-ray microtomography (μCT) images to determine anisotropic elastic parameters as a function of bone density in the area of pedicle screw anchorage. The fabric tensor was mapped in cubic bone volumes by a 3D mean-intercept-length method. Fabric measurements resulted in a high degree of anisotropy (DA = 0.554). For the Young’s and shear moduli as a function of bone volume fraction (BV/TV, bone volume/total volume), an individually fit function was determined and high correlations were found (97.3 ≤ R2 ≤ 99.1,p < 0.005). The results suggest that the mathematical formulation for the relationship between anisotropic elastic constants and BV/TV is applicable to current μCT data of cancellous bone in the osteoporotic lumbar spine. In combination with the obtained results and findings, the developed routine allows determination of elastic constants of osteoporotic lumbar spine. Based on this, the elastic constants determined using homogenization theory can enable efficient investigation of human bone using finite element analysis (FEA). Cancellous Bone with Fabric Tensor Ellipsoid representing anisotropy and principal axis (colored coordinate system) of given trabecular structure ![]()
Collapse
|
14
|
Noonan AM, Brown SHM. Paraspinal muscle pathophysiology associated with low back pain and spine degenerative disorders. JOR Spine 2021; 4:e1171. [PMID: 34611593 PMCID: PMC8479522 DOI: 10.1002/jsp2.1171] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/17/2021] [Accepted: 08/21/2021] [Indexed: 12/18/2022] Open
Abstract
Low back pain disorders affect more than 80% of adults in their lifetime and are the leading cause of global disability. The muscles attaching to the spine (ie, paraspinal muscles) are critical for proper spine health and play a crucial role in the functioning of the spine and whole body; however, reports of muscle dysfunction and insufficiency in chronic LBP (CLBP) patients are common. This article presents a review of the current understanding of the relationship between paraspinal muscle pathophysiology and spine-related disorders. Human literature demonstrates a clear association between altered muscle structure/function, most notably fatty infiltration and fibrosis, and low back pain disorders; other associations, including muscle cell atrophy and fiber type changes, are less clear. Animal literature then provides some mechanistic insight into the complex relationships, including initiating factors and time courses, between the spine and spine muscles under pathological conditions. It is apparent that spine pathology can directly lead to changes in the paraspinal muscle structure, function, and biology. It also appears that changes to the muscle structure and function can directly lead to changes in the spine (eg, deformity); however, this relationship is less well studied. Future work must focus on providing insight into possible mechanisms that regulate spine and paraspinal muscle health, as well as probing how muscle degeneration/dysfunction might be an initiating factor in the progression of spine pathology.
Collapse
Affiliation(s)
- Alex M. Noonan
- Department of Human Health and Nutritional SciencesUniversity of GuelphGuelphOntarioCanada
| | - Stephen H. M. Brown
- Department of Human Health and Nutritional SciencesUniversity of GuelphGuelphOntarioCanada
| |
Collapse
|
15
|
Sacher S, Hernandez CJ, Donnelly E. Characterization of Ultralow Density Cellular Solids: Lessons from 30 years of Bone Biomechanics Research. ADVANCED ENGINEERING MATERIALS 2021; 23:2100206. [PMID: 34456625 PMCID: PMC8389487 DOI: 10.1002/adem.202100206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Indexed: 06/13/2023]
Abstract
Advances in additive manufacturing techniques have enabled the development of micro-architectured materials displaying a combination of low-density and lightweight structures with high specific strength and toughness. The mechanical performance of micro-architectured materials can be assessed using standard techniques; however, when studying low- and ultralow density micro-architectured materials, standard characterization techniques can be subject to experimental artifacts. Additionally, quantitative assessment and comparisons of microarchitectures with distinct lattice patterns is not always straightforward. Cancellous bone is a natural, ultralow density (porosity often exceeding 90%), irregular, cellular solid that has been thoroughly characterized in terms of micro-architecture and mechanical performance over the past 30 years. However, most the literature on cancellous bone mechanical properties and micro-structure-function relationships is in the medical literature and is not immediately accessible to materials designers. Here we provide a brief review of state-of-the-art approaches for characterizing the micro-architecture and mechanical performance of ultralow density cancellous bone, including methods of addressing experimental artifacts during mechanical characterization of ultralow density cellular solids, methods of quantifying microarchitecture, and currently understood structure-function relationships.
Collapse
Affiliation(s)
- Sara Sacher
- Department of Materials Science and Engineering, Cornell University, Ithaca, NY
| | - Christopher J Hernandez
- Research Division, Hospital for Special Surgery, New York, NY
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY
| | - Eve Donnelly
- Department of Materials Science and Engineering, Cornell University, Ithaca, NY
- Research Division, Hospital for Special Surgery, New York, NY
| |
Collapse
|
16
|
Costi JJ, Ledet EH, O'Connell GD. Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence. JOR Spine 2021; 4:e1138. [PMID: 33778410 PMCID: PMC7984003 DOI: 10.1002/jsp2.1138] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 12/04/2020] [Accepted: 12/07/2020] [Indexed: 12/14/2022] Open
Abstract
Biomechanical testing methodologies for the spine have developed over the past 50 years. During that time, there have been several paradigm shifts with respect to techniques. These techniques evolved by incorporating state-of-the-art engineering principles, in vivo measurements, anatomical structure-function relationships, and the scientific method. Multiple parametric studies have focused on the effects that the experimental technique has on outcomes. As a result, testing methodologies have evolved, but there are no standard testing protocols, which makes the comparison of findings between experiments difficult and conclusions about in vivo performance challenging. In 2019, the international spine research community was surveyed to determine the consensus on spine biomechanical testing and if the consensus opinion was consistent with the scientific evidence. More than 80 responses to the survey were received. The findings of this survey confirmed that while some methods have been commonly adopted, not all are consistent with the scientific evidence. This review summarizes the scientific literature, the current consensus, and the authors' recommendations on best practices based on the compendium of available evidence.
Collapse
Affiliation(s)
- John J. Costi
- Biomechanics and Implants Research Group, Medical Device Research Institute, College of Science and EngineeringFlinders UniversityAdelaideAustralia
| | - Eric H. Ledet
- Department of Biomedical EngineeringRensselaer Polytechnic InstituteTroyNew YorkUSA
- Research and Development ServiceStratton VA Medical CenterAlbanyNew YorkUSA
| | - Grace D. O'Connell
- Department of Mechanical EngineeringUniversity of California‐BerkeleyBerkeleyCaliforniaUSA
- Department of Orthopaedic SurgeryUniversity of California‐San FranciscoSan FranciscoCaliforniaUSA
| |
Collapse
|
17
|
Addison BJ, Lieberman DE. Assessing patterns of variation in BV/TV in the calcaneus and C2 vertebra of Gorilla gorilla, Pan troglodytes, and populations of Homo sapiens from the Pleistocene and Holocene that differ in physical activity levels. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2021; 173:337-349. [PMID: 33448347 DOI: 10.1002/ajpa.24064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2019] [Revised: 02/26/2020] [Accepted: 04/10/2020] [Indexed: 11/08/2022]
Abstract
OBJECTIVES Because trabecular bone volume fraction (BV/TV) is influenced by variations in physical activity recent declines in BV/TV in humans are often attributed to modern sedentary lifestyles. This study tests the hypothesis that presumed variations in mechanical loading between groups can predict the observed BV/TV patterns in humans, chimpanzees and gorillas in two bones: the calcaneus which experiences high and well characterized impact forces, and the C2 vertebrae which experiences reduced locomotor forces. MATERIALS AND METHODS BV/TV and other structural variables were quantified from high-resolution microCT scans in gorillas, chimpanzees, and four Homo sapiens populations: Pleistocene, semi-sedentary Natufians; Holocene hunter-gatherers from Point Hope, Alaska; Holocene nomadic pastoralists from medieval Europe; and modern, sedentary Americans. RESULTS In the calcaneal tuberosity, Natufian BV/TV was 36, 46, and 46% greater than Alaskans (p = .02), Europeans (p = .005) and modern Americans (p = .002), respectively, but not significantly different from apes. BV/TV was not significantly different between modern Americans and Alaskans or Europeans. In the C2, Natufian BV/TV was 53 and 25% greater than in the Alaskan (p = .0001) and European (p = .048) populations. DISCUSSION These results suggest that phenomena other than or in addition to variations in physical activity are needed to explain BV/TV patterns observed in H. sapiens, and point to a systemic decline in H. sapiens BV/TV after the Pleistocene.
Collapse
Affiliation(s)
- Brian J Addison
- Department of Human Evolutionary Biology, Harvard University, Cambridge, Massachusetts, United States
| | - Daniel E Lieberman
- Department of Human Evolutionary Biology, Harvard University, Cambridge, Massachusetts, United States
| |
Collapse
|
18
|
Karali A, Kao AP, Zekonyte J, Blunn G, Tozzi G. Micromechanical evaluation of cortical bone using in situ XCT indentation and digital volume correlation. J Mech Behav Biomed Mater 2021; 115:104298. [PMID: 33445104 DOI: 10.1016/j.jmbbm.2020.104298] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 12/22/2020] [Accepted: 12/25/2020] [Indexed: 11/29/2022]
Abstract
The overall mechanical behaviour of cortical bone is strongly dependant on its microstructure. X-ray computed tomography (XCT) has been widely used to identify the microstructural morphology of cortical tissue (i.e. pore network, Haversian and Volkmann's canals). However, the connection between microstructure and mechanics of cortical bone during plastic deformation is unclear. Hence, the purpose of this study is to provide an in-depth evaluation of the interplay of plastic strain building up in relation to changes in the canal network for cortical bone tissue. In situ step-wise XCT indentation was used to introduce a localised load on the surface of the tissue and digital volume correlation (DVC) was employed to assess the three-dimensional (3D) full-field plastic strain distribution in proximity of the indent. It was observed that regions adjacent to the imprint were under tensile strain, whereas the volume underneath experienced compressive strain. Canal loss and disruption was detected in regions of higher compressive strains exceeding -20000 με and crack formation occurred in specimens where Haversian canals were running parallel to the indentation tip. The results of this study outline the relationship between the micromechanical and structural behaviour of cortical bone during plastic deformation, providing information on cortical tissue fracture pathways.
Collapse
Affiliation(s)
- Aikaterina Karali
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
| | | | - Jurgita Zekonyte
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK
| | - Gordon Blunn
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, UK.
| | - Gianluca Tozzi
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
| |
Collapse
|
19
|
Li T, Chen Z, Gao Y, Zhu L, Yang R, Leng H, Huo B. Fluid-solid coupling numerical simulation of trabecular bone under cyclic loading in different directions. J Biomech 2020; 109:109912. [PMID: 32807313 DOI: 10.1016/j.jbiomech.2020.109912] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 06/19/2020] [Accepted: 06/24/2020] [Indexed: 11/16/2022]
Abstract
The structure of a bone tissue is capable of adapting to mechanical loading through the process of bone remodeling, which is regulated by osteoblasts and osteoclasts. Fluid flow within trabecular porosity under cyclic loading is one of the factors stimulating the biological response of osteoblasts and osteoclasts. However, the relation between loading directions and interstitial fluid flow was seldom studied. In the present study, a finite element model based on micro-computed tomographic reconstructions is built by using a mouse femur. Results from the fluid-solid coupling numerical simulation indicate that the loading in different directions generates a distinct distribution of von Mises stress in the bone matrix and a fluid shear stress (FSS) in the bone marrow. The loading along the physiological direction leads to a more uniform distribution of solid stress and produces an FSS level beneficial to the biological response of osteoblasts and osteoclasts compared with those along the non-physiological direction. There was a minimum threshold line of wall FSS with a specific solid stress at the bone surface, suggesting that the wall FSS is mainly induced by the solid strain. These results may offer fundamental data in understanding the mechanical environment around osteoblasts and osteoclasts and the cellular and molecular mechanisms of mechanical loading-induced bone remodeling.
Collapse
Affiliation(s)
- Taiyang Li
- Department of Mechanics, School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, PR China
| | - Zebin Chen
- Department of Mechanics, School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, PR China
| | - Yan Gao
- Department of Mechanics, School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, PR China
| | - Lingsu Zhu
- Laboratory of Biomimetic Nanomaterials, Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, PR China
| | - Ruili Yang
- Laboratory of Biomimetic Nanomaterials, Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, PR China
| | - Huijie Leng
- Department of Orthopaedics, Peking University Third Hospital, Beijing 100191, PR China
| | - Bo Huo
- Department of Mechanics, School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, PR China.
| |
Collapse
|
20
|
Black RA, Houston G. 40th Anniversary Issue: Reflections on papers from the archive on "Biomechanics". Med Eng Phys 2020; 72:70-71. [PMID: 31554579 DOI: 10.1016/j.medengphy.2019.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Richard A Black
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, Scotland, UK.
| | - Gregor Houston
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, Scotland, UK
| |
Collapse
|
21
|
3D-printed PLA/HA composite structures as synthetic trabecular bone: A feasibility study using fused deposition modeling. J Mech Behav Biomed Mater 2019; 103:103608. [PMID: 32090935 DOI: 10.1016/j.jmbbm.2019.103608] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 12/16/2019] [Accepted: 12/25/2019] [Indexed: 11/22/2022]
Abstract
Additive manufacturing has significant advantages, in the biomedical field, allowing for customized medical products where complex architectures can be achieved directly. While additive manufacturing can be used to fabricate synthetic bone models, this approach is limited by the printing resolution, at the level of the trabecular bone architecture. Therefore, the aim of this study was to evaluate the possibilities of using fused deposition modeling (FDM) to this end. To better mimic real bone, both in terms of mechanical properties and biodegradability, a composite of degradable polymer, poly(lactic acid) (PLA), and hydroxyapatite (HA) was used as the filament. Three PLA/HA composite formulations with 5-10-15 wt% HA were evaluated, and scaled up human trabecular bone models were printed using these materials. Morphometric and mechanical properties of the printed models were evaluated by micro-computed tomography, compression and screw pull out tests. It was shown that the trabecular architecture could be reproduced with FDM and PLA by applying a scaling factor of 2-4. The incorporation of HA particles reduced the printing accuracy, with respect to morphology, but showed potential for enhancement of the mechanical properties. The scaled-up models displayed comparable, or slightly enhanced, strength compared to the commonly used polymeric foam synthetic bone models (i.e. Sawbones). Reproducing the trabecular morphology by 3D printed PLA/HA composites appears to be a promising strategy for synthetic bone models, when high printed resolution can be achieved.
Collapse
|
22
|
Cesar R, Bravo-Castillero J, Ramos RR, Pereira CAM, Zanin H, Rollo JMDA. Relating mechanical properties of vertebral trabecular bones to osteoporosis. Comput Methods Biomech Biomed Engin 2019; 23:54-68. [DOI: 10.1080/10255842.2019.1699542] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- R. Cesar
- Department of Mechanical Engineering, São Carlos School of Engineering, University of São Paulo, São Carlos, Brazil
| | - J. Bravo-Castillero
- Instituto de Investigaciones en Matemáticas Aplicadas y en Sistemas (IIMAS), Universidad Nacional Autónoma de México (UNAM), Mexico City, México
- IIMAS UNAM Mérida, Unidad Académica de Yucatán, Parque Científico Tecnológico de Yucatán, Mérida, México
| | - R. R. Ramos
- Facultad de Matemática y Computación, Universidad de La Habana, Havana, Cuba
| | - C. A. M. Pereira
- Orthopedics and Traumatology Institute at the Clinical Hospital, University of São Paulo (USP), São Paulo, Brazil
| | - H. Zanin
- Carbon Sci-Tech labs, School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil
| | - J. M. D. A. Rollo
- Department of Materials Engineering, São Carlos School of Engineering, University of São Paulo, São Carlos, Brazil
| |
Collapse
|
23
|
Material properties of human lumbar intervertebral discs across strain rates. Spine J 2019; 19:2013-2024. [PMID: 31326631 DOI: 10.1016/j.spinee.2019.07.012] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 07/16/2019] [Accepted: 07/17/2019] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT The use of finite element (FE) methods to study the biomechanics of the intervertebral disc (IVD) has increased over recent decades due to their ability to quantify internal stresses and strains throughout the tissue. Their accuracy is dependent upon realistic, strain-rate dependent material properties, which are challenging to acquire. PURPOSE The aim of this study was to use the inverse FE technique to characterize the material properties of human lumbar IVDs across strain rates. STUDY DESIGN A human cadaveric experimental study coupled with an inverse finite element study. METHODS To predict the structural response of the IVD accurately, the material response of the constituent structures was required. Therefore, compressive experiments were conducted on 16 lumbar IVDs (39±19 years) to obtain the structural response. An FE model of each of these experiments was developed and then run through an inverse FE algorithm to obtain subject-specific constituent material properties, such that the structural response was accurate. RESULTS Experimentally, a log-linear relationship between IVD stiffness and strain rate was observed. The material properties obtained through the subject-specific inverse FE optimization of the annulus fibrosus (AF) fiber and AF fiber ground matrix allowed a good match between the experimental and FE response. This resulted in a Young modulus of AF fibers (-MPa) to strain rate (ε˙, /s) relationship of YMAF=31.5ln(ε˙)+435.5, and the C10 parameter of the Neo-Hookean material model of the AF ground matrix was found to be strain-rate independent with an average value of 0.68 MPa. CONCLUSIONS These material properties can be used to improve the accuracy, and therefore predictive ability of FE models of the spine that are used in a wide range of research areas and clinical applications. CLINICAL SIGNIFICANCE Finite element models can be used for many applications including investigating low back pain, spinal deformities, injury biomechanics, implant design, design of protective systems, and degenerative disc disease. The accurate material properties obtained in this study will improve the predictive ability, and therefore clinical significance of these models.
Collapse
|
24
|
Wood Z, Lynn L, Nguyen JT, Black MA, Patel M, Barak MM. Are we crying Wolff? 3D printed replicas of trabecular bone structure demonstrate higher stiffness and strength during off-axis loading. Bone 2019; 127:635-645. [PMID: 31390534 PMCID: PMC6939675 DOI: 10.1016/j.bone.2019.08.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 08/01/2019] [Accepted: 08/02/2019] [Indexed: 11/18/2022]
Abstract
Roux's principle of bone functional adaptation postulates that bone tissue, and particularly trabecular bone tissue, responds to mechanical stimuli by adjusting (modeling) its architecture accordingly. Hence, it predicts that the new modeled trabecular structure is mechanically improved (stiffer and stronger) in line with the habitual in vivo loading direction. While previous studies found indirect evidence to support this theory, direct support was so far unattainable. This is attributed to the fact that each trabecular bone is unique, and that trabecular bone tissue tends to be damaged during mechanical testing. Consequently, a unique modeled trabecular structure can be mechanically tested only along one direction and a comparison to other directions for that specific structure is impossible. To address this issue, we have 3D printed 10 replicas of a trabecular structure from a sheep talus cropped along the 3 principal axes of the bone and in line with the principal direction of loading (denoted on-axis model). Next, we have rotated the same cropped trabecular structure in increments of 10° up to 90° to the bone principal direction of loading (denoted off-axis models) and printed 10 replicas of each off-axis model. Finally, all on-axis and off-axis 3D printed replicas were loaded in compression until failure and trabecular structure stiffness and strength were calculated. Contrary to our prediction, and conflicting with Roux's principle of bone functional adaptation, we found that a trabecular structure loaded off-axis tended to have higher stiffness and strength values when compared to the same trabecular structure loaded on-axis. These unexpected results may not disprove Roux's principle of bone functional adaptation, but they do imply that trabecular bone adaptation may serve additional purposes than simply optimizing bone structure to one principal loading scenario and this suggests that we still don't fully understand bone modeling in its entirety.
Collapse
Affiliation(s)
- Zach Wood
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA
| | - Lisa Lynn
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA
| | - Jack T Nguyen
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA
| | - Margaret A Black
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA
| | - Meha Patel
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA
| | - Meir M Barak
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA; Department of Veterinary Biomedical Sciences, College of Veterinary Medicine, Long Island University, Brookville, NY 11548, USA.
| |
Collapse
|
25
|
Marter AD, Dickinson AS, Pierron F, Fong YKK, Browne M. Characterising the compressive anisotropic properties of analogue bone using optical strain measurement. Proc Inst Mech Eng H 2019; 233:954-960. [PMID: 31210622 PMCID: PMC6661718 DOI: 10.1177/0954411919855150] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The validity of conclusions drawn from pre-clinical tests on orthopaedic devices depends upon accurate characterisation of the support materials: frequently, polymer foam analogues. These materials often display anisotropic mechanical behaviour, which may considerably influence computational modelling predictions and interpretation of experiments. Therefore, this study sought to characterise the anisotropic mechanical properties of a range of commonly used analogue bone materials, using non-contact multi-point optical extensometry method to account for the effects of machine compliance and uneven loading. Testing was conducted on commercially available 'cellular', 'solid' and 'open-cell' Sawbone blocks with a range of densities. Solid foams behaved largely isotropically. However, across the available density range of cellular foams, the average Young's modulus was 23%-31% lower (p < 0.005) perpendicular to the foaming direction than parallel to it, indicating elongation of cells with foaming. The average Young's modulus of open-celled foams was 25%-59% higher (p < 0.05) perpendicular to the foaming direction than parallel to it. This is thought to result from solid planes of material that were observed perpendicular to the foaming direction, stiffening the bulk material. The presented data represent a reference to help researchers design, model and interpret tests using these materials.
Collapse
Affiliation(s)
- Alex D Marter
- 1 Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Alexander S Dickinson
- 1 Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Fabrice Pierron
- 2 Engineering Materials Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Yin Ki Kiki Fong
- 1 Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - Martin Browne
- 1 Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| |
Collapse
|
26
|
Buell TJ, Bess S, Xu M, Schwab FJ, Lafage V, Ames CP, Shaffrey CI, Smith JS. Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: a finite element analysis. J Neurosurg Spine 2019; 30:574-584. [PMID: 30738393 DOI: 10.3171/2018.10.spine18429] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Accepted: 10/11/2018] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Proximal junctional kyphosis (PJK) is, in part, due to altered segmental biomechanics at the junction of rigid instrumented spine and relatively hypermobile non-instrumented adjacent segments. Proper application of posteriorly anchored polyethylene tethers (i.e., optimal configuration and tension) may mitigate adjacent-segment stress and help prevent PJK. The purpose of this study was to investigate the impact of different tether configurations and tensioning (preloading) on junctional range-of-motion (ROM) and other biomechanical indices for PJK in long instrumented spine constructs. METHODS Using a validated finite element model of a T7-L5 spine segment, testing was performed on intact spine, a multilevel posterior screw-rod construct (PS construct; T11-L5) without tether, and 15 PS constructs with different tether configurations that varied according to 1) proximal tether fixation of upper instrumented vertebra +1 (UIV+1) and/or UIV+2; 2) distal tether fixation to UIV, to UIV-1, or to rods; and 3) use of a loop (single proximal fixation) or weave (UIV and/or UIV+1 fixation in addition to UIV+1 and/or UIV+2 proximal attachment) of the tether. Segmental ROM, intradiscal pressure (IDP), inter- and supraspinous ligament (ISL/SSL) forces, and screw loads were assessed under variable tether preload. RESULTS PS construct junctional ROM increased abruptly from 10% (T11-12) to 99% (T10-11) of baseline. After tethers were grouped by most cranial proximal fixation (UIV+1 vs UIV+2) and use of loop versus weave, UIV+2 Loop and/or Weave most effectively dampened junctional ROM and adjacent-segment stress. Different distal fixation and use of loop versus weave had minimal effect. The mean segmental ROM at T11-12, T10-11, and T9-10, respectively, was 6%, 40%, and 99% for UIV+1 Loop; 6%, 44%, and 99% for UIV+1 Weave; 5%, 23%, and 26% for UIV+2 Loop; and 5%, 24%, and 31% for UIV+2 Weave.Tethers shared loads with posterior ligaments; consequently, increasing tether preload tension reduced ISL/SSL forces, but screw loads increased. Further attenuation of junctional ROM and IDP reversed above approximately 100 N tether preload, suggesting diminished benefit for biomechanical PJK prophylaxis at higher preload tensioning. CONCLUSIONS In this study, finite element analysis demonstrated UIV+2 Loop and/or Weave tether configurations most effectively mitigated adjacent-segment stress in long instrumented spine constructs. Tether preload dampened ligament forces at the expense of screw loads, and an inflection point (approximately 100 N) was demonstrated above which junctional ROM and IDP worsened (i.e., avoid over-tightening tethers). Results suggest tether configuration and tension influence PJK biomechanics and further clinical research is warranted.
Collapse
Affiliation(s)
- Thomas J Buell
- 1Department of Neurosurgery, University of Virginia Health System, Charlottesville, Virginia
| | - Shay Bess
- 2Denver International Spine Center, Presbyterian St. Luke's/Rocky Mountain Hospital for Children, Denver, Colorado
| | - Ming Xu
- 3NuVasive, Inc., San Diego, California
| | - Frank J Schwab
- 4Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York; and
| | - Virginie Lafage
- 4Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York; and
| | - Christopher P Ames
- 5Department of Neurological Surgery, University of California, San Francisco, California
| | - Christopher I Shaffrey
- 1Department of Neurosurgery, University of Virginia Health System, Charlottesville, Virginia
| | - Justin S Smith
- 1Department of Neurosurgery, University of Virginia Health System, Charlottesville, Virginia
| |
Collapse
|
27
|
Zhao S, Arnold M, Ma S, Abel RL, Cobb JP, Hansen U, Boughton O. Standardizing compression testing for measuring the stiffness of human bone. Bone Joint Res 2018; 7:524-538. [PMID: 30258572 PMCID: PMC6138811 DOI: 10.1302/2046-3758.78.bjr-2018-0025.r1] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Objectives The ability to determine human bone stiffness is of clinical relevance in many fields, including bone quality assessment and orthopaedic prosthesis design. Stiffness can be measured using compression testing, an experimental technique commonly used to test bone specimens in vitro. This systematic review aims to determine how best to perform compression testing of human bone. Methods A keyword search of all English language articles up until December 2017 of compression testing of bone was undertaken in Medline, Embase, PubMed, and Scopus databases. Studies using bulk tissue, animal tissue, whole bone, or testing techniques other than compression testing were excluded. Results A total of 4712 abstracts were retrieved, with 177 papers included in the analysis; 20 studies directly analyzed the compression testing technique to improve the accuracy of testing. Several influencing factors should be considered when testing bone samples in compression. These include the method of data analysis, specimen storage, specimen preparation, testing configuration, and loading protocol. Conclusion Compression testing is a widely used technique for measuring the stiffness of bone but there is a great deal of inter-study variation in experimental techniques across the literature. Based on best evidence from the literature, suggestions for bone compression testing are made in this review, although further studies are needed to establish standardized bone testing techniques in order to increase the comparability and reliability of bone stiffness studies. Cite this article: S. Zhao, M. Arnold, S. Ma, R. L. Abel, J. P. Cobb, U. Hansen, O. Boughton. Standardizing compression testing for measuring the stiffness of human bone. Bone Joint Res 2018;7:524–538. DOI: 10.1302/2046-3758.78.BJR-2018-0025.R1.
Collapse
Affiliation(s)
- S Zhao
- The MSk Lab, Imperial College London, Charing Cross Hospital, London, UK
| | - M Arnold
- The MSk Lab, Imperial College London, Charing Cross Hospital, London, UK
| | - S Ma
- The MSk Lab, Imperial College London, Charing Cross Hospital, London, UK and Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, UK
| | - R L Abel
- The MSk Lab, Imperial College London, Charing Cross Hospital, London, UK
| | - J P Cobb
- The MSk Lab, Imperial College London, Charing Cross Hospital, London, UK
| | - U Hansen
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - O Boughton
- The MSk Lab, Imperial College London, Charing Cross Hospital, London, UK and Department of Mechanical Engineering, Imperial College London, London, UK
| |
Collapse
|
28
|
DANESI VALENTINA, FALDINI CESARE, CRISTOFOLINI LUCA. METHODS FOR THE CHARACTERIZATION OF THE LONG-TERM MECHANICAL PERFORMANCE OF CEMENTS FOR VERTEBROPLASTY AND KYPHOPLASTY: CRITICAL REVIEW AND SUGGESTIONS FOR TEST METHODS. J MECH MED BIOL 2018. [DOI: 10.1142/s0219519417300022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
There is a growing interest towards bone cements for use in vertebroplasty and kyphoplasty, as such spine procedures are becoming more and more common. Such cements feature different compositions, including both traditional acrylic cements and resorbable and bioactive materials. Due to the different compositions and intended use, the mechanical requirements of cements for spinal applications differ from those of traditional cements used in joint replacement. Because of the great clinical implications, it is very important to assess their long-term mechanical competence in terms of fatigue strength and creep. This paper aims at offering a critical overview of the methods currently adopted for such mechanical tests. The existing international standards and guidelines and the literature were searched for publications relevant to fatigue and creep of cements for vertebroplasty and kyphoplasty. While standard methods are available for traditional bone cements in general, no standard indicates specific methods or acceptance criteria for fatigue and creep of cements for vertebroplasty and kyphoplasty. Similarly, a large number of papers were published on cements for joint replacements, but only few cover fatigue and creep of cements for vertebroplasty and kyphoplasty. Furthermore, the literature was analyzed to provide some indications of tests parameters and acceptance criteria (number of cycles, duration in time, stress levels, acceptable amount of creep) for possible tests specifically relevant to cements for spinal applications.
Collapse
Affiliation(s)
- VALENTINA DANESI
- Department of Industrial Engineering, Alma Mater Studiorum — Università di Bologna, Italy
| | - CESARE FALDINI
- Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum — Università di Bologna, Italy
- Department of Orthopaedics and Trauma Surgery, Università di Bologna — Istituto Ortopedico Rizzoli, Bologna, Italy
| | - LUCA CRISTOFOLINI
- Department of Industrial Engineering, Alma Mater Studiorum — Università di Bologna, Italy
| |
Collapse
|
29
|
Putz F, Morak R, Elsaesser MS, Balzer C, Braxmeier S, Bernardi J, Paris O, Reichenauer G, Hüsing N. Setting Directions: Anisotropy in Hierarchically Organized Porous Silica. CHEMISTRY OF MATERIALS : A PUBLICATION OF THE AMERICAN CHEMICAL SOCIETY 2017; 29:7969-7975. [PMID: 28989232 PMCID: PMC5627989 DOI: 10.1021/acs.chemmater.7b03032] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 08/31/2017] [Indexed: 05/29/2023]
Abstract
Structural hierarchy, porosity, and isotropy/anisotropy are highly relevant factors for mechanical properties and thereby the functionality of porous materials. However, even though anisotropic and hierarchically organized, porous materials are well known in nature, such as bone or wood, producing the synthetic counterparts in the laboratory is difficult. We report for the first time a straightforward combination of sol-gel processing and shear-induced alignment to create hierarchical silica monoliths exhibiting anisotropy on the levels of both, meso- and macropores. The resulting material consists of an anisotropic macroporous network of struts comprising 2D hexagonally organized cylindrical mesopores. While the anisotropy of the mesopores is an inherent feature of the pores formed by liquid crystal templating, the anisotropy of the macropores is induced by shearing of the network. Scanning electron microscopy and small-angle X-ray scattering show that the majority of network forming struts is oriented towards the shearing direction; a quantitative analysis of scattering data confirms that roughly 40% of the strut volume exhibits a preferred orientation. The anisotropy of the material's macroporosity is also reflected in its mechanical properties; i.e., the Young's modulus differs by nearly a factor of 2 between the directions of shear application and perpendicular to it. Unexpectedly, the adsorption-induced strain of the material exhibits little to no anisotropy.
Collapse
Affiliation(s)
- Florian Putz
- Chemistry
and Physics of Materials, Paris Lodron University
Salzburg, 5020 Salzburg, Austria
| | - Roland Morak
- Institute
of Physics, Montanuniversität Leoben, 8700 Leoben, Austria
| | - Michael S. Elsaesser
- Chemistry
and Physics of Materials, Paris Lodron University
Salzburg, 5020 Salzburg, Austria
| | - Christian Balzer
- Bavarian
Center for Applied Energy Research, Würzburg, 97074 Würzburg, Germany
| | - Stephan Braxmeier
- Bavarian
Center for Applied Energy Research, Würzburg, 97074 Würzburg, Germany
| | | | - Oskar Paris
- Institute
of Physics, Montanuniversität Leoben, 8700 Leoben, Austria
| | - Gudrun Reichenauer
- Bavarian
Center for Applied Energy Research, Würzburg, 97074 Würzburg, Germany
| | - Nicola Hüsing
- Chemistry
and Physics of Materials, Paris Lodron University
Salzburg, 5020 Salzburg, Austria
| |
Collapse
|
30
|
Nguyen VH, Rosi G, Naili S, Michel A, Raffa ML, Bosc R, Meningaud JP, Chappard C, Takano N, Haiat G. Influence of anisotropic bone properties on the biomechanical behavior of the acetabular cup implant: a multiscale finite element study. Comput Methods Biomech Biomed Engin 2017; 20:1312-1325. [PMID: 28768422 DOI: 10.1080/10255842.2017.1357703] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Although the biomechanical behavior of the acetabular cup (AC) implant is determinant for the surgical success, it remains difficult to be assessed due to the multiscale and anisotropic nature of bone tissue. The aim of the present study was to investigate the influence of the anisotropic properties of peri-implant trabecular bone tissue on the biomechanical behavior of the AC implant at the macroscopic scale. Thirteen bovine trabecular bone samples were imaged using micro-computed tomography (μCT) with a resolution of 18 μm. The anisotropic biomechanical properties of each sample were determined at the scale of the centimeter based on a dedicated method using asymptotic homogenization. The material properties obtained with this multiscale approach were used as input data in a 3D finite element model to simulate the macroscopic mechanical behavior of the AC implant under different loading conditions. The largest stress and strain magnitudes were found around the equatorial rim and in the polar area of the AC implant. All macroscopic stiffness quantities were significantly correlated (R2 > 0.85, p < 6.5 e-6) with BV/TV (bone volume/total volume). Moreover, the maximum value of the von Mises stress field was significantly correlated with BV/TV (R2 > 0.61, p < 1.6 e-3) and was always found at the bone-implant interface. However, the mean value of the microscopic stress (at the scale of the trabeculae) decrease as a function of BV/TV for vertical and torsional loading and do not depend on BV/TV for horizontal loading. These results highlight the importance of the anisotropic properties of bone tissue.
Collapse
Affiliation(s)
- Vu-Hieu Nguyen
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Giuseppe Rosi
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Salah Naili
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Adrien Michel
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Maria-Letizia Raffa
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Romain Bosc
- b INSERM U955 , Université Paris-Est , Créteil , France
| | | | - Christine Chappard
- c Laboratoire Bioingénierie Biomécanique Ostéo-Articulaires, UMR CNRS 7052 , Université Paris Diderot , Paris , France
| | - Naoki Takano
- d Faculty of Science and Engineering, Department of Mechanical Engineering , Keio University , Yokohama , Japan
| | - Guillaume Haiat
- e Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208 , Créteil , France.,f École de technologie supérieure , Montreal , Canada.,g Research Center, Hôpital du Sacré-Cœur de Montréal , Montreal , Canada
| |
Collapse
|
31
|
Abstract
This manuscript will provide an overview of how the age and osteoporosis related changes in mechanical properties of bone affect the stability of osteosynthesis constructs, both from a mechanical as well as from a clinical perspective. The manuscript will also address some of the principles of fracture fixation for osteoporotic fractures and discuss applications of osteoporotic fracture fixation at sites typically affected by fragility fractures, namely the distal radius, the proximal humerus, the femur and the spine. The primary aim of operative treatment in elderly individuals is the avoidance of immobilization of the patient. In selected cases conservative treatment might be required. Generally, choice of treatment should be individualized and based on the evaluation of patient-specific, fracture-specific and surgeon-specific aspects. The orthopaedic surgeon plays an essential role in enabling functional recovery by providing good surgery but a multidisciplinary approach is essential in order to support the patient to regain his/her quality of life after fragility fracture. Overall, the therapy of fractures in osteoporotic bone in the elderly requires a multidisciplinary therapeutic acute care concept including treatment of co-morbidities and correct choice of timing, and technique of the operative intervention.
Collapse
Affiliation(s)
- Christian von Rüden
- Institute of Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Germany; Institute of Biomechanics, Paracelsus Medical UniversitySalzburg, Austria
| | - Peter Augat
- Institute of Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Germany; Institute of Biomechanics, Paracelsus Medical UniversitySalzburg, Austria.
| |
Collapse
|
32
|
Mohd Effendy N, Abdullah S, Yunoh MFM, Shuid AN. Time and dose-dependent effects of Labisia pumila on the bone strength of postmenopausal osteoporosis rat model. BMC COMPLEMENTARY AND ALTERNATIVE MEDICINE 2015; 15:58. [PMID: 25887391 PMCID: PMC4364645 DOI: 10.1186/s12906-015-0567-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Accepted: 02/19/2015] [Indexed: 11/10/2022]
Abstract
BACKGROUND Post-menopausal osteoporosis has long been treated and prevented by estrogen replacement therapy (ERT). Despite its effectiveness, ERT is associated with serious adverse effects. Labisia pumila var. alata (LP) is a herb with potential as an alternative agent to ERT due to its phytoestrogenic, antioxidative and anti-inflammatory effects on bone. This study aimed to determine the effects of LP supplementation on bone biomechanical strength of postmenopausal osteoporosis rat model. METHODS Ninety-six female Sprague-Dawley rats aged 4 to 5 months old were randomly divided into six groups; six rats in the baseline group (BL) and eighteen rats in each group of; Sham- operated (Sham), ovariectomised control (OVXC) and ovariectomised with daily oral gavages of Premarin at 64.5 μg/kg (ERT), LP at 20 mg/kg (LP20) and LP at 100 mg/kg (LP100) respectively. These groups were subdivided into three, six and nine weeks of treatment periods. Rats in BL group were euthanized before the start of the study, while other rats were euthanized after completion of their treatments. Femora were dissected out for biomechanical strength analysis using Instron Universal Model 5848 Micro Tester. RESULTS OVXC group showed deterioration in the bone biomechanical strength with time. Both ERT and LP supplemented rats showed improvements in bone strength parameters such as maximum load, displacement, stiffness, stress, and Young Modulus. The most improved bone strength was seen in rats given LP at the dose of 100 mg/kg for nine weeks. CONCLUSION LP supplementation at 100 mg/kg was more effective than ERT in reversing ovariectomy-induced bone biomechanical changes.
Collapse
Affiliation(s)
- Nadia Mohd Effendy
- Department of Pharmacology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abd Aziz, 50300 KL, Kuala Lumpur, Malaysia.
| | - Shahrum Abdullah
- Department of Mechanical and Materials Engineering, Faculty of Engineering, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
| | - Mohd Faridz Mod Yunoh
- Department of Mechanical and Materials Engineering, Faculty of Engineering, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
| | - Ahmad Nazrun Shuid
- Department of Pharmacology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abd Aziz, 50300 KL, Kuala Lumpur, Malaysia.
| |
Collapse
|
33
|
Reimeringer M, Nuno N. Effect of femoral mechanical properties on primary stability of cementless total hip arthroplasty: a finite element analysis. ACTA ACUST UNITED AC 2014. [DOI: 10.12989/aba.2014.1.3.187] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
34
|
Wang W, Baran GR, Garg H, Betz RR, Moumene M, Cahill PJ. The Benefits of Cement Augmentation of Pedicle Screw Fixation Are Increased in Osteoporotic Bone: A Finite Element Analysis. Spine Deform 2014; 2:248-259. [PMID: 27927345 DOI: 10.1016/j.jspd.2014.03.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2013] [Revised: 02/03/2014] [Accepted: 03/17/2014] [Indexed: 10/25/2022]
Abstract
STUDY DESIGN Biomechanical study using a finite element model of a normal and osteoporotic lumbar vertebrae comparing resistance with axial pullout and bending forces on polymethylmethacrylate-augmented and non-augmented pedicle screws. OBJECTIVE To compare the effect of cement augmentation of pedicle screw fixation in normal and osteoporotic bone with 2 different techniques of cement delivery. SUMMARY OF BACKGROUND DATA Various clinical and biomechanical studies have addressed the benefits of cement augmentation of pedicle screws, but none have evaluated whether this effect is similar, magnified, or attenuated in osteoporotic bone compared with normal bone. In addition, no study has compared the biomechanical strength of augmented pedicle screws using cement delivery through the pedicle screw with delivery through a pilot hole. METHODS This study was funded by a grant from DePuy Synthes Spine. Normal and osteoporotic lumbar vertebrae with pedicle screws were simulated. The models were tested for screw pullout strength with and without cement augmentation. Two methods of cement delivery were also tested. Both methods were tested using 1 and 2.5 cm3 volume of cement infiltrated in normal and osteoporotic bone. RESULTS The increase in screw pullout force was proportionally greater in osteoporotic bone with equivalent volumes of cement delivered. The researchers found that 1 and 2.5 cm3 of cement infiltrated bone volume resulted in an increase in pullout force by about 50% and 120% in normal bone, and by about 64% and 156% in osteoporotic bone, respectively. The delivery method had only a minimal effect on pullout force when 2.5 cm3 of cement was injected (<4% difference). CONCLUSIONS Cement augmentation increases the fixation strength of pedicle screws, and this effect is proportionately greater in osteoporotic bone. Cement delivery through fenestrated screws and delivery through a pilot hole result in comparable pullout strength at higher cement volumes.
Collapse
Affiliation(s)
- Wenhai Wang
- Department of Mechanical Engineering, College of Engineering, Temple University, 1947 North 12th Street, Philadelphia, PA 19104, USA
| | - George R Baran
- Department of Mechanical Engineering, College of Engineering, Temple University, 1947 North 12th Street, Philadelphia, PA 19104, USA
| | - Hitesh Garg
- Artemis Health Institute, Sector 51, Gurgaon 122001, Haryana, India
| | - Randal R Betz
- Shriners Hospitals for Children-Philadelphia, 3551 North Broad Street, Philadelphia, PA 19140, USA
| | - Missoum Moumene
- DePuy Synthes Spine, Inc., 325 Paramount Drive, Raynham, MA 02767, USA
| | - Patrick J Cahill
- Shriners Hospitals for Children-Philadelphia, 3551 North Broad Street, Philadelphia, PA 19140, USA.
| |
Collapse
|
35
|
Willems NMBK, Langenbach GEJ, Stoop R, den Toonder JMJ, Mulder L, Zentner A, Everts V. Higher number of pentosidine cross-links induced by ribose does not alter tissue stiffness of cancellous bone. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 42:15-21. [PMID: 25063086 DOI: 10.1016/j.msec.2014.05.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2013] [Revised: 04/07/2014] [Accepted: 05/06/2014] [Indexed: 01/22/2023]
Abstract
The role of mature collagen cross-links, pentosidine (Pen) cross-links in particular, in the micromechanical properties of cancellous bone is unknown. The aim of this study was to examine nonenzymatic glycation effects on tissue stiffness of demineralized and non-demineralized cancellous bone. A total of 60 bone samples were derived from mandibular condyles of six pigs, and assigned to either control or experimental groups. Experimental handling included incubation in phosphate buffered saline alone or with 0.2M ribose at 37°C for 15 days and, in some of the samples, subsequent complete demineralization of the sample surface using 8% EDTA. Before and after experimental handling, bone microarchitecture and tissue mineral density were examined by means of microcomputed tomography. After experimental handling, the collagen content and the number of Pen, hydroxylysylpyridinoline (HP), and lysylpyridinoline (LP) cross-links were estimated using HPLC, and tissue stiffness was assessed by means of nanoindentation. Ribose treatment caused an up to 300-fold increase in the number of Pen cross-links compared to nonribose-incubated controls, but did not affect the number of HP and LP cross-links. This increase in the number of Pen cross-links had no influence on tissue stiffness of both demineralized and nondemineralized bone samples. These findings suggest that Pen cross-links do not play a significant role in bone tissue stiffness.
Collapse
Affiliation(s)
- Nop M B K Willems
- Dept. of Orthodontics, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, The Netherlands; Dept. of Oral Cell Biology and Functional Anatomy, MOVE Research Institute, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, The Netherlands.
| | - Geerling E J Langenbach
- Dept. of Oral Cell Biology and Functional Anatomy, MOVE Research Institute, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, The Netherlands
| | - Reinout Stoop
- Dept. of Metabolic Health Research, TNO, P.O. Box 2215, 2301 CE Leiden, The Netherlands
| | - Jaap M J den Toonder
- Dept. of Mechanical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Lars Mulder
- Dept. of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Andrej Zentner
- Dept. of Orthodontics, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, The Netherlands
| | - Vincent Everts
- Dept. of Oral Cell Biology and Functional Anatomy, MOVE Research Institute, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, The Netherlands
| |
Collapse
|
36
|
Cyganik Ł, Binkowski M, Kokot G, Rusin T, Popik P, Bolechała F, Nowak R, Wróbel Z, John A. Prediction of Young׳s modulus of trabeculae in microscale using macro-scale׳s relationships between bone density and mechanical properties. J Mech Behav Biomed Mater 2014; 36:120-34. [PMID: 24837330 DOI: 10.1016/j.jmbbm.2014.04.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Revised: 04/17/2014] [Accepted: 04/20/2014] [Indexed: 10/25/2022]
Abstract
According to the literature, there are many mathematical relationships between density of the trabecular bone and mechanical properties obtained in macro-scale testing. In micro-scale, the measurements provide only the ranges of Young׳s modulus of trabeculae, but there are no experimentally tested relationships allowing the calculation of the distribution of Young׳s modulus of trabeculae within these experimental ranges. This study examined the applicability of relationships between bone density and mechanical properties obtained in macro-scale testing for the calculation of Young׳s modulus distribution in micro-scale. Twelve cubic specimens from eleven femoral heads were cut out and micro-computed tomography (micro-CT) scanned. A mechanical compression test and Digital Image Correlation (DIC) measurements were performed to obtain the experimental displacement and strain full-field evaluation for each specimen. Five relationships between bone density and Young׳s modulus were selected for the test; those were given by Carter and Hayes (1977), Ciarelli et al. (2000), Kaneko et al. (2004), Keller (1994) for the human femur, and Li and Aspden, 1997. Using these relationships, five separate finite element (FE) models were prepared, with different distribution of Young׳s modulus of trabeculae for each specimen. In total, 60 FE analyses were carried out. The obtained displacement and strain full-field measurements from numerical calculations and experiment were compared. The results indicate that the highest accuracy of the numerical calculation was obtained for the Ciarelli et al. (2000) relationship, where the relative error was 17.87% for displacements and 50.94 % for strains. Therefore, the application of the Ciarelli et al. (2000) relationship in the microscale linear FE analysis is possible, but mainly to determine bone displacement.
Collapse
Affiliation(s)
- Łukasz Cyganik
- X-ray Microtomography Lab, Department of Biomedical Computer Systems, Institute of Computer Science, Faculty of Computer and Materials Science, University of Silesia, 75 Pulku Piechoty 1, budynek H, segment C, pok. P7, 41-500 Chorzów, Poland
| | - Marcin Binkowski
- X-ray Microtomography Lab, Department of Biomedical Computer Systems, Institute of Computer Science, Faculty of Computer and Materials Science, University of Silesia, 75 Pulku Piechoty 1, budynek H, segment C, pok. P7, 41-500 Chorzów, Poland.
| | - Grzegorz Kokot
- Institute of Computational Mechanics and Engineering, Silesian University of Technology, ul. Konarskiego 18A, 44-100 Gliwice, Poland
| | - Tomasz Rusin
- Elhys Sp. z o.o., MTS Systems Corporation Representative in Poland, ul. Naukowa 45, 02-463 Warszawa, Poland
| | - Paulina Popik
- X-ray Microtomography Lab, Department of Biomedical Computer Systems, Institute of Computer Science, Faculty of Computer and Materials Science, University of Silesia, 75 Pulku Piechoty 1, budynek H, segment C, pok. P7, 41-500 Chorzów, Poland
| | - Filip Bolechała
- Medical College, Jagiellonian University, ul. Grzegórzecka 16, 31-531 Kraków, Poland
| | - Roman Nowak
- Medical University of Silesia, School of Medicine with the Division of Dentistry, Chair and Department of Orthopaedics, WSS no. 5, ul. Medyków 1, 41-200 Sosnowiec, Poland
| | - Zygmunt Wróbel
- X-ray Microtomography Lab, Department of Biomedical Computer Systems, Institute of Computer Science, Faculty of Computer and Materials Science, University of Silesia, 75 Pulku Piechoty 1, budynek H, segment C, pok. P7, 41-500 Chorzów, Poland
| | - Antoni John
- Institute of Computational Mechanics and Engineering, Silesian University of Technology, ul. Konarskiego 18A, 44-100 Gliwice, Poland
| |
Collapse
|
37
|
Compressive fatigue properties of a commercially available acrylic bone cement for vertebroplasty. Biomech Model Mechanobiol 2014; 13:1199-207. [DOI: 10.1007/s10237-014-0566-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Accepted: 02/24/2014] [Indexed: 10/25/2022]
|
38
|
Willems NMBK, Mulder L, den Toonder JMJ, Zentner A, Langenbach GEJ. The correlation between mineralization degree and bone tissue stiffness in the porcine mandibular condyle. J Bone Miner Metab 2014; 32:29-37. [PMID: 23624768 DOI: 10.1007/s00774-013-0464-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2012] [Accepted: 03/21/2013] [Indexed: 11/26/2022]
Abstract
The aim of this study was to correlate the local tissue mineral density (TMD) with the bone tissue stiffness. It was hypothesized that these variables are positively correlated. Cancellous and cortical bone samples were derived from ten mandibular condyles taken from 5 young and 5 adult female pigs. The bone tissue stiffness was assessed in three directions using nanoindentation. At each of three tested sides 5 indents were made over the width of 5 single bone elements, resulting in a total number of 1500 indents. MicroCT was used to determine the local TMD at the indented sites. The TMD and the bone tissue stiffness were higher in bone from the adult animals than from the young ones, but did not differ between cancellous and cortical bone. In the adult group, both the TMD and the bone tissue stiffness were higher in the center than at the surface of the bone elements. The mean TMD, thus ignoring the local mineral distribution, had a coefficient of determination (R(2)) with the mean bone tissue stiffness of 0.55, p < 0.05, whereas the correlation between local bone tissue stiffness and the concomitant TMD appeared to be weak (R (2) 0.07, p < 0.001). It was concluded that the mineralization degree plays a larger role in bone tissue stiffness in cancellous than in cortical bone. Our data based on bone from the mandibular condyle suggest that the mineralization degree is not a decisive determinant of the local bone tissue stiffness.
Collapse
Affiliation(s)
- Nop M B K Willems
- Department of Orthodontics, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, The Netherlands,
| | | | | | | | | |
Collapse
|
39
|
Assari S, Kaufmann A, Darvish K, Park J, Haw J, Safadi F, Rehman S. Biomechanical comparison of locked plating and spiral blade retrograde nailing of supracondylar femur fractures. Injury 2013; 44:1340-5. [PMID: 23672795 DOI: 10.1016/j.injury.2013.04.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2013] [Revised: 04/04/2013] [Accepted: 04/14/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Biomechanical comparison between locked plating and retrograde nailing of supracondylar femur fractures with simulated postoperative weight-bearing. METHODS The Locking Condylar Plate (LCP) and Retrograde/Antegrade EX Femoral Nail (RAFN) were tested using 10 paired elderly cadaveric femurs, divided into Normal and Low Bone Mineral Density (BMD) groups, with a simulated AO/OTA type 33-A3 supracondylar femur fracture. Each specimen was subjected to 200,000 loading cycles in an attempt to simulate six weeks of postoperative recovery with full weight-bearing for an average individual. The construct's subsidence due to cyclic loading, and axial stiffness before and after the cyclic loading were measured and their correlation with BMD was studied. The two implants were compared in a paired study within each BMD group. RESULTS LCP constructs showed higher axial stiffness compared to RAFN for both Normal and Low BMD groups (80% and 57%, respectively). After cyclic loading, axial stiffness of both constructs decreased by 20% and RAFN constructs resulted in twice as much subsidence (1.9 ± 0.6mm). Two RAFN constructs with Low BMD failed after a few cycles whereas the matched pairs fixed with LCP failed after 70,000 cycles. CONCLUSIONS The RAFN constructs experienced greater subsidence and reduced axial stiffness compared to the LCP constructs. In Low BMD specimens, the RAFN constructs had a higher risk of failure.
Collapse
Affiliation(s)
- Soroush Assari
- Department of Mechanical Engineering, Temple University, Philadelphia, PA 19122, United States
| | | | | | | | | | | | | |
Collapse
|
40
|
Cylinders or walls? A new computational model to estimate the MR transverse relaxation rate dependence on trabecular bone architecture. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 27:349-61. [PMID: 24061609 DOI: 10.1007/s10334-013-0402-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 08/22/2013] [Accepted: 08/22/2013] [Indexed: 10/26/2022]
Abstract
OBJECTIVE Bone density is distributed in a complex network of interconnecting trabecular plates and rods that are interspersed with bone marrow. A computational model to assess the dependence of the relaxation rate on the geometry of bone can consider the distribution of bone material in the form of two components: cylinders and open walls (walls with gaps). We investigate whether the experimentally known dependence of the transverse relaxation rate on the trabecular bone structure can be usefully interpreted in terms of these two components. MATERIALS AND METHODS We established a computer model based on an elementary computational cell. The model includes a variable number of open walls and infinitely long cylinders as well as multiple geometric parameters. The transverse relaxation rate is computed as a function of these parameters. Within the model, increasing the trabecular spacing with a fixed trabecular radius is equivalent to thinning the trabeculae while maintaining constant spacing. RESULTS Increasing the number of cylinder and wall gap elements beyond their nearest neighbors does not change the transverse relaxation rate. Although the absolute contribution to the relaxation due to open walls is on average more important than that due to cylinders, the latter drops off rapidly. The change on transverse relaxation rate is larger for changing cylinder geometry than for changing wall geometry, as it can be seen from the effect on the relaxation rate when trabecular spacing is varied, compared to varying the size of wall gaps. CONCLUSION Our results provide strong evidence that trabecular thinning, which is associated with increasing age, decreases the relaxation rates. The effect of thinning plates and rods on the transverse relaxation can be understood in terms of simple cylinders and open walls. A reduction in the relaxation rate can be seen as an indication of thinning cylinders, corresponding to reduced bone stability and ultimately, osteoporosis.
Collapse
|
41
|
Effect of posterolateral disc replacement on kinematics and stress distribution in the lumbar spine: A finite element study. Med Eng Phys 2013; 35:357-64. [DOI: 10.1016/j.medengphy.2012.05.013] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 05/26/2012] [Accepted: 05/30/2012] [Indexed: 11/20/2022]
|
42
|
Alonso-Rasgado T, Jimenez-Cruz D, Bailey CG, Mandal P, Board T. Changes in the stress in the femoral head neck junction after osteochondroplasty for hip impingement: a finite element study. J Orthop Res 2012; 30:1999-2006. [PMID: 22707347 DOI: 10.1002/jor.22164] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2011] [Accepted: 05/11/2012] [Indexed: 02/04/2023]
Abstract
The surgical treatment of femoroacetabular impingement (FAI) often involves femoral osteochondroplasty. One risk of this procedure is fracture of the femoral neck. We developed a finite element (FE) model to investigate the relationship between depth of resection and femoral neck stress. CT data were used to obtain the geometry of a typical cam-type hip, and a 3D FE model was constructed to predict stress in the head-neck after resection surgery. The model accounted for the forces acting on the head and abductor muscular forces. Bone resection was performed virtually to incremental resection depths. The stresses were calculated for five resection depths and for five different activities (i) standing on one leg (static case); (ii) two-to-one-to-two leg standing; (iii) normal walking; (iv) walking down stairs; and (v) a knee bend. In general, both the average Von Mises stresses and the area of bone that yielded significantly increased at a resection depth of ≥10 mm. The knee bend and walking down stairs demonstrated the highest stresses. The FE model predicts that fracture is likely to occur in the resection area first following removal of a third (10 mm) or more of the diameter of the femoral neck. We suggest that when surgeons perform osteochondroplasty for hip impingement, the depth of resection should be limited to 10 mm.
Collapse
Affiliation(s)
- Teresa Alonso-Rasgado
- School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, Manchester M13 9PL, UK.
| | | | | | | | | |
Collapse
|
43
|
Bajuri M, Kadir MRA, Raman MM, Kamarul T. Mechanical and functional assessment of the wrist affected by rheumatoid arthritis: A finite element analysis. Med Eng Phys 2012; 34:1294-302. [DOI: 10.1016/j.medengphy.2011.12.020] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2011] [Revised: 11/09/2011] [Accepted: 12/21/2011] [Indexed: 11/30/2022]
|
44
|
Yang J, Sangiorgio SN, Borkowski SL, Silvestro C, De Nardo L, Daraio C, Ebramzadeh E. Site-Specific Quantification of Bone Quality Using Highly Nonlinear Solitary Waves. J Biomech Eng 2012; 134:101001. [DOI: 10.1115/1.4007364] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Osteoporosis is a well recognized problem affecting millions of individuals worldwide. The ability to diagnose problems in an effective, efficient, and affordable manner and identify individuals at risk is essential. Site-specific assessment of bone mechanical properties is necessary, not only in the process of fracture risk assessment, but may also be desirable for other applications, such as making intraoperative decisions during spine and joint replacement surgeries. The present study evaluates the use of a one-dimensional granular crystal sensor to measure the elastic properties of bone at selected locations via direct mechanical contact. The granular crystal is composed of a tightly packed chain of particles that interact according to the Hertzian contact law. Such chains represent one of the simplest systems to generate and propagate highly nonlinear acoustic signals in the form of compact solitary waves. First, we investigated the sensitivity of the sensor to known variations in bone density using a synthetic cancellous bone substitute, representing clinical bone quality ranging from healthy to osteoporotic. Once the relationship between the signal response and known bone properties was established, the sensor was used to assess the bone quality of ten human cadaveric specimens. The efficacy and accuracy of the sensor was then investigated by comparing the sensor measurements with the bone mineral density (BMD) obtained using dual-energy x-ray absorptiometry (DEXA). The results indicate that the proposed technique is capable of detecting differences in bone quality. The ability to measure site-specific properties without exposure to radiation has the potential to be further developed for clinical applications.
Collapse
Affiliation(s)
- Jinkyu Yang
- Graduate Aerospace Laboratories (GALCIT), California Institute of Technology, Pasadena, CA 91125; Mechanical Engineering Department, University of South Carolina, Columbia, SC 29208
| | - Sophia N. Sangiorgio
- Department of Orthopedic Surgery,University of California, Los Angeles,J. Vernon Luck, MDOrthopedic Research CenterLos Angeles Orthopedic Hospital,Los Angels, CA 90007
| | - Sean L. Borkowski
- J. Vernon Luck, MD Orthopaedic Research Center, Los Angeles Orthopedic Hospital, Los Angeles, CA 90007
| | - Claudio Silvestro
- Dipartimento di Chimica, Materiali e Ingegneria Chimica “G. Natta,” Politecnico di Milano, Milano 20133, Italy
| | - Luigi De Nardo
- Dipartimento di Chimica, Materiali e Ingegneria Chimica “G. Natta,” Politecnico di Milano, Milano 20133, Italy
| | - Chiara Daraio
- Graduate Aerospace Laboratories (GALCIT), California Institute of Technology, Pasadena, CA 91125
| | - Edward Ebramzadeh
- Department of Orthopedic Surgery,University of California, Los Angeles,J. Vernon Luck, MD Orthopedic Research Center, Los Angeles Orthopaedic Hospital, Los Angeles, CA 90007
| |
Collapse
|
45
|
The effect of cup orientation and coverage on contact mechanics and range of motion of metal-on-metal hip resurfacing arthroplasty. Proc Inst Mech Eng H 2012. [DOI: 10.1177/0954411912456926] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Implant malpositioning has been identified as a factor associated with clinical failures of metal-on-metal hip resurfacings (MoMHRs). This study investigated the effect of cup orientation and cup coverage on the contact mechanics (incidence of edge-loading) and range of motion (ROM) of MoMHR. Three generic MoMHRs with differing amounts of cup coverage were considered at various orientations. Contact area and contact pressure at the bearing surface were predicted for each design using finite element (FE) method. The ROM was determined based on the geometry overlap. Edge contact was found at lower angles of inclination (65°) for lower coverage cup designs; however, they also provided the greatest ROM. Conversely, cups with greater coverage did not exhibit edge contact until the cup was more steeply positioned (75°), however ROM was reduced. This study enables both sets of variable to be considered in the design of metal-on-metal bearings in hip.
Collapse
|
46
|
The use of a transition rod may prevent proximal junctional kyphosis in the thoracic spine after scoliosis surgery: a finite element analysis. Spine (Phila Pa 1976) 2012; 37:E687-95. [PMID: 22210013 DOI: 10.1097/brs.0b013e318246d4f2] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Finite element analysis. OBJECTIVE Via finite element analysis: (1) to demonstrate the abnormal forces present at the top of a scoliosis construct, (2) to demonstrate the importance of an intact interspinous and supraspinous ligament (ISL/SSL) complex, and (3) to evaluate a transition rod (a rod that has a short taper to a smaller diameter at one end) as an implant solution to diminish these pathomechanics, regardless of the integrity of the ISL/SSL complex. SUMMARY OF BACKGROUND DATA The pathophysiology of increased nucleus pressure and increased angular displacement may contribute to proximal junctional kyphosis. Furthermore, high implant stress can be demonstrated at the upper end of the construct, possibly leading to the risk of implant failure. METHODS A finite element model was constructed to simulate a thoracic spinal fusion. The model was altered to remove the ISL/SSL complex at the level above the construct. Then, the model was altered again by extending the construct one level superior with a transition rod. The angular displacement, the maximum pressure in the nucleus, and stress within the implant were extracted from computational results under 2 conditions: load control and displacement control. The testing was performed with both titanium and stainless steel implants. RESULTS Pressure in the nucleus and angular displacement are all increased when the ISL/SSL complex is removed immediately above the instrumented levels, whereas the screw pullout force and maximum stress within the screw are decreased. The nucleus pressure increases by more than 50%. The angular displacement increases by 19% to 26%. This absence of the ISL/SSL complex simulates the clinical scenario that occurs when these structures are iatrogenically detached. Abnormal mechanics can be restored to normal level by extending the construct rostral one level with a transition rod. Furthermore, the elevated nucleus pressure and angular displacement noted even when the ISL/SSL complex is intact can be avoided with the use of a transition rod. Under the same bending moment (3 Nm), the nucleus pressure at the level immediately cephalad is up to 23% lower than the pressure in a standard construct. The angular displacement is 18% to 19% less than the standard construct. The maximum implant stress is also decreased by as much as 60%. CONCLUSION Finite element modeling suggests that the pathomechanics at the proximal end of a scoliosis construct may be diminished by preserving the ISL/SSL complex and possibly completely eliminated with the use of rods with a diameter transition at the most proximal level.
Collapse
|
47
|
Guérard S, Chevalier Y, Moreschi H, Defontaine M, Callé S, Mitton D. Young’s modulus repeatability assessment using cycling compression loading on cancellous bone. Proc Inst Mech Eng H 2011; 225:1113-7. [DOI: 10.1177/0954411911416858] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
For various applications, precision of the Young’s modulus of cancellous bone specimens is needed. However, measurement variability is rarely given. The aim of this study was to assess the Young’s modulus repeatability using a uniaxial cyclic compression protocol on embedded specimens of human cancellous bone. Twelve specimens from 12 human calcanei were considered. The specimens were first defatted and then 1 or 2 mm at the ends were embedded in an epoxy resin. The compression experiment consists in applying 20 compressive cycles between 0.2 per cent and 0.6 per cent strain with a 2 Hz loading frequency. The coefficient of variation of the current protocol was found to be 1.2 per cent. This protocol showed variability similar to the end-cap technique (considered as a reference). It can be applied on porous specimen (especially human bone) and requires minimal bone length to limit end-artifact variability. The current method could be applied in association with noninvasive measurements (such as ultrasound) with full compatibility. This possibility opens the way for bone damage follow-up based on Young’s modulus monitoring.
Collapse
Affiliation(s)
- S Guérard
- Arts et Metiers ParisTech, LBM, Paris, France
| | - Y Chevalier
- Arts et Metiers ParisTech, LBM, Paris, France
| | - H Moreschi
- Université F. Rabelais, UMRS, Imagerie et Cerveau, INSERM U930,CNRS ERL 3106, Tours, France
| | - M Defontaine
- Université F. Rabelais, UMRS, Imagerie et Cerveau, INSERM U930,CNRS ERL 3106, Tours, France
| | - S Callé
- Université F. Rabelais, UMRS, Imagerie et Cerveau, INSERM U930,CNRS ERL 3106, Tours, France
| | - D Mitton
- Arts et Metiers ParisTech, LBM, Paris, France
- Université de Lyon, Lyon, France; IFSTTAR, LBMC, Bron; Université Lyon 1, Villeurbanne, France
| |
Collapse
|
48
|
Follet H, Viguet-Carrin S, Burt-Pichat B, Dépalle B, Bala Y, Gineyts E, Munoz F, Arlot M, Boivin G, Chapurlat RD, Delmas PD, Bouxsein ML. Effects of preexisting microdamage, collagen cross-links, degree of mineralization, age, and architecture on compressive mechanical properties of elderly human vertebral trabecular bone. J Orthop Res 2011; 29:481-8. [PMID: 20957742 DOI: 10.1002/jor.21275] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2010] [Accepted: 09/02/2010] [Indexed: 02/04/2023]
Abstract
Previous studies have shown that the mechanical properties of trabecular bone are determined by bone volume fraction (BV/TV) and microarchitecture. The purpose of this study was to explore other possible determinants of the mechanical properties of vertebral trabecular bone, namely collagen cross-link content, microdamage, and mineralization. Trabecular bone cores were collected from human L2 vertebrae (n = 49) from recently deceased donors 54-95 years of age (21 men and 27 women). Two trabecular cores were obtained from each vertebra, one for preexisting microdamage and mineralization measurements, and one for BV/TV and quasi-static compression tests. Collagen cross-link content (PYD, DPD, and PEN) was measured on surrounding trabecular bone. Advancing age was associated with impaired mechanical properties, and with increased microdamage, even after adjustment by BV/TV. BV/TV was the strongest determinant of elastic modulus and ultimate strength (r² = 0.44 and 0.55, respectively). Microdamage, mineralization parameters, and collagen cross-link content were not associated with mechanical properties. These data indicate that the compressive strength of human vertebral trabecular bone is primarily determined by the amount of trabecular bone, and notably unaffected by normal variation in other factors, such as cross-link profile, microdamage and mineralization.
Collapse
Affiliation(s)
- Helene Follet
- INSERM U831, University of Lyon, Lyon F-69008, France.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Lee CY, Chan SH, Lai HY, Lee ST. A method to develop an in vitro osteoporosis model of porcine vertebrae: histological and biomechanical study. J Neurosurg Spine 2011; 14:789-98. [PMID: 21395393 DOI: 10.3171/2010.12.spine10453] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT The porcine spine is widely used as an alternative to the human spine for both in vivo and in vitro spinal biomechanical studies because of the limited availability and high cost of human specimens. The aim of this study was to develop a reproducible in vitro osteoporotic vertebral model for spinal implant investigations. METHODS Four mature domestic porcine lumbar spines (L1-5) were obtained. An in vitro decalcification method was used to decrease the mineral content of the porcine vertebrae, with Ca-chelating agents (0.5 M EDTA solution, pH 7.4) that altered the bone mineral density (BMD). Lumbar-spine area BMD was evaluated using dual-energy x-ray absorptiometry; spine volumetric BMD and spine geometry were assessed by central quantitative CT scanning to monitor the time it took the decalcification process to induce the WHO-defined standard of osteoporosis. Micro-computed topography provided information on the 3D microarchitecture of the lumbar vertebrae before and after decalcification with EDTA. Hematoxylin and eosin staining of lumbar vertebrae was performed. Both the control (5 specimens) and osteoporotic vertebrae (5 specimens) were biomechanically tested to measure compressive strength. RESULTS The differences in area BMD measurements before and after the demineralizing processes were statistically significant (p < 0.001). The results of the compression test before and after the demineralizing processes were also statistically significant (p < 0.001). CONCLUSIONS The data imply that the acid demineralizing process may be useful for producing a vertebra that has some biomechanical properties that are consistent with osteoporosis in humans.
Collapse
Affiliation(s)
- Ching-yi Lee
- Department of Neurosurgery, Chang Gung University & Chang Gung Memorial Hospital, Taoyuan, Taiwan
| | | | | | | |
Collapse
|
50
|
Abstract
STUDY DESIGN In vitro compressive load-displacement experiments on intact rat lumbar vertebrae and on the same vertebrae after part of their trabecular bone was removed. OBJECTIVE To determine the contribution of the trabecular bone component to the stiffness and strength of rat lumbar vertebrae. SUMMARY OF BACKGROUND DATA Vertebral fractures are common in the aging population, possibly resulting from the deterioration of the mechanical properties of vertebral bone. Studies of the contribution of trabecular bone to the mechanical behavior of whole vertebra were published, but yielded mixed results. Here, we propose a novel optical metrology approach to address this important question. METHODS The bodies of intact rat lumbar vertebrae and the bodies of the same vertebrae after part of their trabecular bone was removed were loaded within their elastic region in a wet environment. The amount of trabecular bone removed was determined by micro-computer tomography scanning. Deformation maps of the dorsal vertebral surface of the intact and manipulated vertebrae were obtained using an optical metrology method, and compared. Intact and manipulated vertebrae were also loaded to failure in compression and their strengths and stiffness were compared. RESULTS The preferred trabecular orientation was found to be along the anterior-posterior axis, which is similar to humans. Removal of up to 42% of the trabecular tissue in the intact vertebrae did not significantly affect lumbar vertebral stiffness. However, removal of even smaller amounts of the intact trabecular tissue significantly reduced vertebral strength. CONCLUSION Trabeculae in rat lumbar vertebrae fulfill an important role in failure resistance (strength), but have little or no effect on the deformational behavior (stiffness) of the bone. These results differ from previous results we reported for rat femora, where removal of trabecular bone surprisingly increased the stiffness of the whole bone, and suggest that trabecular tissue may have different functions depending on anatomic location, bone function and morphology, and mode of loading.
Collapse
|