Venter AR. Protein analysis by desorption electrospray ionization mass spectrometry. MASS SPECTROMETRY REVIEWS 2024. [PMID: 39056172 DOI: 10.1002/mas.21900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 05/22/2024] [Accepted: 07/08/2024] [Indexed: 07/28/2024]
Abstract
This review presents progress made in the ambient analysis of proteins, in particular by desorption electrospray ionization-mass spectrometry (DESI-MS). Related ambient ionization techniques are discussed in comparison to DESI-MS only to illustrate the larger context of protein analysis by ambient ionization mass spectrometry. The review describes early and current approaches for the analysis of undigested proteins, native proteins, tryptic digests, and indirect protein determination through reporter molecules. Applications to mass spectrometry imaging for protein spatial distributions, the identification of posttranslational modifications, determination of binding stoichiometries, and enzymatic transformations are discussed. The analytical capabilities of other ambient ionization techniques such as LESA and nano-DESI currently exceed those of DESI-MS for in situ surface sampling of intact proteins from tissues. This review shows, however, that despite its many limitations, DESI-MS is making valuable contributions to protein analysis. The challenges in sensitivity, spatial resolution, and mass range are surmountable obstacles and further development and improvements to DESI-MS is justified.
Collapse
Affiliation(s)
- Andre R Venter
- Department of Chemistry, Western Michigan University, Kalamazoo, Michigan, USA
| |
Collapse
|
2
|
Chen W, Yuan K, He Q, Li Q, Luo J, Chu F, Wang H, Feng H, Pan Y. Long term online desalting analysis of MS/LC-MS using thermal assisted recrystallization ionization. Talanta 2024; 274:125981. [PMID: 38583325 DOI: 10.1016/j.talanta.2024.125981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 03/06/2024] [Accepted: 03/20/2024] [Indexed: 04/09/2024]
Abstract
Mass spectrometric analysis of non-volatile salts containing samples remains challenging due to salt-induced ion suppression and contamination. This challenge is even more pronounced for a liquid chromatography-mass spectrometry analysis, where the accumulation of salts in the transmission system poses an ongoing problem. In this study, a novel thermal assisted recrystallization ionization mass spectrometry (TARI-MS) device was developed to achieve efficient on-line desalting and prolonged analysis of saline samples. The core component of this device was a heated plate positioned between the electrospray unit and the MS inlet. The desalting mechanism was demonstrated as the spontaneous separation of target molecules from salts during the "crystallization" process. After optimization, the angle between the nebulizer and the heated plate was 45°; the distance between the front end of the heated plate and the MS inlet was 2 mm; the distance between the front edge of the heated plate and the center of the sample spray projected onto the heating plate was 3 mm; the distance between the emitter of nebulizer and the heated plate was 3 mm. TARI-MS realized direct analysis of eight drugs dissolved in eight commonly used non-volatile salts solutions (up to 0.5 mol/L). The high sensitivity, repeatability, linearity, accuracy, and intra- and inter-day precision of TARI-MS confirm its reliability as a robust tool for the analysis of saline samples. Furthermore, TARI-MS allowed continuous analysis of salty eluates of LC for up to nearly 1 h without maintenance and verified the feasibility of LC-MS analysis through detecting a five-drug mixture and a crude aripiprazole product. Finally, six impurities in the crude aripiprazole product were successfully detected by LC-TARI-MS. The established method holds promise for applications across academic and pharmaceutical domains.
Collapse
Affiliation(s)
- Weiwei Chen
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Kailong Yuan
- China Tobacco Zhejiang Industrial Co., Ltd., Hangzhou, Zhejiang, 310008, PR China
| | - Quan He
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Qing Li
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Jing Luo
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Fengjian Chu
- Key Laboratory of Advanced Micro/Nano Electronic Devices and Smart Systems of Zhejiang, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Huiwen Wang
- Analysis Center of Agrobiology and Environmental Sciences, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Hongru Feng
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China.
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China.
| |
Collapse
|
3
|
Caleb Bagley M, Garrard KP, Muddiman DC. The development and application of matrix assisted laser desorption electrospray ionization: The teenage years. MASS SPECTROMETRY REVIEWS 2023; 42:35-66. [PMID: 34028071 DOI: 10.1002/mas.21696] [Citation(s) in RCA: 31] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 05/24/2023]
Abstract
In the past 15 years, ambient ionization techniques have witnessed a significant incursion into the field of mass spectrometry imaging, demonstrating their ability to provide complementary information to matrix-assisted laser desorption ionization. Matrix-assisted laser desorption electrospray ionization is one such technique that has evolved since its first demonstrations with ultraviolet lasers coupled to Fourier transform-ion cyclotron resonance mass spectrometers to extensive use with infrared lasers coupled to orbitrap-based mass spectrometers. Concurrently, there have been transformative developments of this imaging platform due to the high level of control the principal group has retained over the laser technology, data acquisition software (RastirX), instrument communication, and image processing software (MSiReader). This review will discuss the developments of MALDESI since its first laboratory demonstration in 2005 to the most recent advances in 2021.
Collapse
Affiliation(s)
- Michael Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- The Precision Engineering Consortium, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
4
|
Li C, DeVor A, Wang J, Valentine SJ, Li P. Rapid and flexible online desalting using Nafion-coated melamine sponge for mass spectrometry analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9341. [PMID: 35729084 PMCID: PMC9357145 DOI: 10.1002/rcm.9341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 06/17/2022] [Accepted: 06/17/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The performance of mass spectrometry (MS) analysis is often affected by the presence of salt ions. To achieve optimal MS detection results, desalting is necessary for samples with high salt concentrations. We report a rapid, low-cost and flexible online desalting method using Nafion-coated sponge. This method is easy to perform and can be implemented to a wide range of customized fluidic systems. METHODS Nafion-coated melamine sponge was fabricated by soaking a glass tube containing a melamine sponge in Nafion solution and then drying overnight. The online desalting workflow is comprised of three major parts: (1) Syringe pump, which provides a continuous flow for the online fluid system; (2) Nafion sponge in a glass tube, where the online desalting of sample solution happens; (3) Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI), which is an ionization technique to ionize the desalted analytes. RESULTS Effective online desalting of a 10 mM NaCl solution was demonstrated for a wide range of molecules including small molecules, peptides, DNAs, and proteins using a flow rate of 10 μL/min. By incorporating multiple pieces of the Nafion-coated sponge, effective desalting for ubiquitin and cytochrome c (Cyt-c) from physiological buffers, including phosphate-buffered saline (PBS) and tris-buffered saline (TBS), were also achieved. For molecules that are sensitive to low pH conditions after desalting, a R-SO3 NH4 -type Nafion-coated sponge was fabricated. Desalting of ubiquitin, oligosaccharide, and DNA oligomers from 10 mM NaCl or 10 mM KCl solutions was demonstrated. CONCLUSIONS Flexible, low-cost, and efficient online desalting was achieved by the Nafion-coated sponge. A variety of molecules ranging from small molecules, peptides, proteins to oligosaccharides and DNAs can be desalted for MS analysis. The desalting by Nafion sponge has great potential for desalting applications that require customized fluidic design and rapid analysis.
Collapse
Affiliation(s)
- Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Amanda DeVor
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Jing Wang
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| |
Collapse
|
5
|
A convenient online desalination tube coupled with mass spectrometry for the direct detection of iodinated contrast media in untreated human spent hemodialysates. PLoS One 2022; 17:e0268751. [PMID: 35666735 PMCID: PMC9170114 DOI: 10.1371/journal.pone.0268751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 05/06/2022] [Indexed: 11/19/2022] Open
Abstract
Background Mass spectrometry (MS) analysis using direct infusion of biological fluids is often problematic due to high salts/buffers. Iodinated contrast media (ICM) are frequently used for diagnostic imaging purposes, sometimes inducing acute kidney injury (AKI) in patients with reduced kidney function. Therefore, detection of ICM in spent hemodialysates is important for AKI patients who require urgent continuous hemodiafiltration (CHDF) because it allows noninvasive assessment of the patient’s treatment. In this study, we used a novel desalination tube before MS to inject the sample directly and detect ICM. Methods Firstly, spent hemodialysates of one patient were injected directly into the electrospray ionization (ESI) source equipped with a quadrupole time-of-flight mass spectrometer (Q-TOF MS) coupled to an online desalination tube for the detection of ICM and other metabolites. Thereafter, spent hemodialysates of two patients were injected directly into the ESI source equipped with a triple quadrupole mass spectrometer (TQ-MS) connected to that online desalination tube to confirm the detection of ICM. Results We detected iohexol (an ICM) from untreated spent hemodialysates of the patient-administered iohexol for computed tomography using Q-TOF MS. Using MRM profile analysis, we have confirmed the detection of ICM in the untreated spent hemodialysates of the patients administered for coronary angiography before starting CHDF. Using the desalination tube, we observed approximately 178 times higher signal intensity and 8 times improved signal-to-noise ratio for ioversol (an ICM) compared to data obtained without the desalination tube. This system was capable of tracking the changes of ioversol in spent hemodialysates of AKI patients by measuring spent hemodialysates. Conclusion The online desalination tube coupled with MS showed the capability of detecting iohexol and ioversol in spent hemodialysates without additional sample preparation or chromatographic separation. This approach also demonstrated the capacity to monitor the ioversol changes in patients’ spent hemodialysates.
Collapse
|
6
|
|
7
|
Lin R, Lu Q, Lin Z, Hang W, Huang B. Laser-induced acoustic desorption coupled with electrospray ionization mass spectrometry for rapid qualitative and quantitative analysis of glucocorticoids illegally added in creams. Analyst 2021; 145:6625-6631. [PMID: 32789335 DOI: 10.1039/d0an00962h] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We present a strategy for the coupling of laser-induced acoustic desorption (LIAD) with electrospray ionization (ESI) mass spectrometry. Different from desorption electrospray ionization (DESI) or paper spray ionization (PSI), the technique decouples the desorption of analytes from the subsequent ionization. The desorption is initiated by a shock wave induced in 10 μm titanium (Ti) foil coated with the sample, irradiated from the rear side by a laser beam, and then the desorbed neutral analytes are post-ionized by ESI and finally characterized by quadrupole/time-of-flight (Q-TOF) mass spectrometry (MS). Separating desorption from the ionization event makes this technique flexible and decreases the matrix effect and salt effect. Various kinds of common creams containing glucocorticoids are investigated using LIAD/ESI/MS without sample pretreatment. The results show that volatile and nonvolatile analytes in creams are sampled simultaneously by LIAD, providing a convenient way for high-throughput screening of the target compounds. In addition, quantitation of glucocorticoids in creams was performed by analyzing samples with decreasing concentrations of analytes (dexamethasone (20 μg g-1) used as an internal standard (IS)), until no more signal was observed. The limits of detection (LODs) of glucocorticoids were determined experimentally to be ranging from 0.7 μg g-1 for triamcinolone acetonide to 10 μg g-1 for beclomethasone dipropionate, which are two orders of magnitude lower than the regular usage of glucocorticoids (beclomethasone dipropionate 0.25 mg g-1, triamcinolone acetonide 0.25 mg g-1). Overall, LIAD/ESI/MS is demonstrated to be of great practical importance for rapid qualitative and quantitative analysis of glucocorticoids in creams, and good sensitivity can be achieved without tedious sample pretreatment and time-consuming chromatographic separation, irrespective of the presence of complex matrices.
Collapse
Affiliation(s)
- Rongkun Lin
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Qiao Lu
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Zheng Lin
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Wei Hang
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Benli Huang
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
8
|
He F, Yin J, Wang T, Pu J, Dai J, Zhao Z, Duan Y. Synergetic effect of laser and micro-fabricated glow discharge plasma in a new ion source for ambient mass spectrometry. Talanta 2021; 225:121847. [PMID: 33592690 DOI: 10.1016/j.talanta.2020.121847] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 10/27/2020] [Accepted: 10/30/2020] [Indexed: 10/23/2022]
Abstract
A new ambient ionization technique named laser ablation micro-fabricated glow discharge plasma (LA-MFGDP) was developed for mass spectrometry in this study. This technique used low energy laser for sample ablation and ionized sample aerosol with MFGDP in sequence. The combination of laser ablation and MFGDP exhibited a synergetic effect that significantly improved the performance of MFGDP. Experimental results showed that MFGDP dominated the ionization process while laser played the role of desorption in LA-MFGDP. [M+H]+ and M+ proved that proton transfer reactions and charge transfer reactions were involved in the ionization process, respectively, indicating that the ionization character was the same as MFGDP. LA-MFGDP could analyze less volatile samples that were unable to be detected by MFGDP because laser significantly improved the ionization capability of MFGDP. Strong ion signals were obtained by LA-MFGDP with low sample consumption. The limits of detection (LODs) of LA-MFGDP was as low as three orders of magnitude than that of MFGDP, which demonstrated that LA-MFGDP possessed an outstanding advantage in detecting trace substances. LA-MFGDP was successfully applied to detect pharmaceutical tablets without any pretreatment. Benefited from the excellent performance, LA-MFGDP offers great potential in broadening the application of ambient mass spectrometry.
Collapse
Affiliation(s)
- Feiyao He
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu, 610064, PR China
| | - Jinwei Yin
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu, 610064, PR China
| | - Tianzhi Wang
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu, 610064, PR China
| | - Juan Pu
- College of Chemistry, Sichuan University, Chengdu, 610064, PR China
| | - Jianxiong Dai
- College of Chemistry and Material Science, Northwest University, Xi'an, 710069, PR China
| | - Zhongjun Zhao
- College of Chemical Engineering, Sichuan University, Chengdu, 610064, PR China.
| | - Yixiang Duan
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu, 610064, PR China.
| |
Collapse
|
9
|
Campos AM, Nuzzo G, Varone A, Italiani P, Boraschi D, Corda D, Fontana A. Direct LC-MS/MS Analysis of Extra- and Intracellular Glycerophosphoinositol in Model Cancer Cell Lines. Front Immunol 2021; 12:646681. [PMID: 33737939 PMCID: PMC7960645 DOI: 10.3389/fimmu.2021.646681] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 02/04/2021] [Indexed: 12/20/2022] Open
Abstract
Glycerophosphoinositols (GPIs) are water-soluble bioactive phospholipid derivatives of increasing interest as intracellular and paracrine mediators of eukaryotic cell functions. The most representative compound of the family is glycerophosphoinositol (GroPIns), an ubiquitous component of mammalian cells that participates in cell proliferation, cell survival and cell response to stimuli. Levels and activity of this compound vary among cell types and deciphering these functions requires accurate measurements in in vitro and in vivo models. The conventional approaches for the analysis of GroPIns pose several issues in terms of sensitivity and product resolution, especially when the product is in the extracellular milieu. Here we present an UPLC-MS study for the quantitative analysis of this lipid derivative in cells and, for the first time, culture supernatants. The method is based on a solid-phase extraction that allows for fast desalting and analyte concentration. The robustness of the procedure was tested on the simultaneous measurements of intra- and extracellular levels of GroPIns in a number of human cell lines where it has been shown that the non-transformed cells are characterized by high extracellular level of GroPIns, whereas the tumor cells tended to have higher intracellular levels.
Collapse
Affiliation(s)
- Ana Margarida Campos
- Consiglio Nazionale delle Ricerche, Institute of Biomolecular Chemistry, Pozzuoli, Italy.,Consiglio Nazionale delle Ricerche, Institute of Biochemistry and Cell Biology, Naples, Italy
| | - Genoveffa Nuzzo
- Consiglio Nazionale delle Ricerche, Institute of Biomolecular Chemistry, Pozzuoli, Italy
| | - Alessia Varone
- Consiglio Nazionale delle Ricerche, Institute of Biochemistry and Cell Biology, Naples, Italy
| | - Paola Italiani
- Consiglio Nazionale delle Ricerche, Institute of Biochemistry and Cell Biology, Naples, Italy
| | - Diana Boraschi
- Consiglio Nazionale delle Ricerche, Institute of Biochemistry and Cell Biology, Naples, Italy
| | - Daniela Corda
- Consiglio Nazionale delle Ricerche, Institute of Biochemistry and Cell Biology, Naples, Italy.,Consiglio Nazionale delle Ricerche, Department of Biomedical Sciences Rome, Italy
| | - Angelo Fontana
- Consiglio Nazionale delle Ricerche, Institute of Biomolecular Chemistry, Pozzuoli, Italy.,Department of Biology, University of Naples Federico II, Naples, Italy
| |
Collapse
|
10
|
Xu S, Xue J, Bai Y, Liu H. High-Throughput Single-Cell Immunoassay in the Cellular Native Environment Using Online Desalting Dual-Spray Mass Spectrometry. Anal Chem 2020; 92:15854-15861. [DOI: 10.1021/acs.analchem.0c03167] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Shuting Xu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Jinjuan Xue
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Yu Bai
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| |
Collapse
|
11
|
Alves MR, Sauer JS, Prather KA, Grassian VH, Wilkins CL. Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization as a Technique for the Characterization of Salt-Containing Organic Samples. Anal Chem 2020; 92:8845-8851. [PMID: 32441094 DOI: 10.1021/acs.analchem.0c00361] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Typical ionization techniques used for mass spectrometry (MS) analysis face challenges when trying to analyze organic species in a high-salt environment. Here, we present results using a recently developed ionization source, liquid sampling-atmospheric pressure glow discharge (LS-APGD), for marine-relevant salt-containing organic samples. Using two representative sample types, a triglyceride mixture and dissolved organic matter, this method is compared to traditional electrospray ionization (ESI) under saline and neat conditions. LS-APGD produced equal or higher (15%+) ion intensities than those of ESI for both salt-containing and neat samples, although important differences linked with adduct formation in high-salt conditions explain the molecular species observed. For all sample types, LS-APGD observed a higher diversity of molecules under optimized settings (0.25 mm electrode spacing at 20 mA) compared to traditional ESI. Furthermore, because the LS-APGD source ionizes molecular species in a ∼1 mm3 volume plasma using a low-power source, there is the potential for this method to be applied in field studies, eliminating desalting procedures, which can be time-consuming and nonideal for low-concentration species.
Collapse
Affiliation(s)
- Michael R Alves
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, California 92093, United States
| | - Jon S Sauer
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, California 92093, United States
| | - Kimberly A Prather
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, California 92093, United States.,Scripps Institution of Oceanography, University of California San Diego, La Jolla, California 92037, United States
| | - Vicki H Grassian
- Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, California 92093, United States.,Scripps Institution of Oceanography, University of California San Diego, La Jolla, California 92037, United States.,Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Charles L Wilkins
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, Arkansas 72701, United States
| |
Collapse
|
12
|
A microfluidic platform integrating paper adsorption-based sample clean-up and voltage-assisted liquid desorption electrospray ionization mass spectrometry for biological sample analysis. Talanta 2020; 217:121106. [PMID: 32498849 DOI: 10.1016/j.talanta.2020.121106] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Revised: 04/28/2020] [Accepted: 04/30/2020] [Indexed: 12/17/2022]
Abstract
Clinical application of direct sampling electrospray ionization mass spectrometry (ESI-MS) remains limited due to problems associated with very "dirty" sample matrices. Herein we report on a microfluidic platform that allows direct mass spectrometric analysis of serum samples of microliter sizes. The platform integrates in-line paper adsorption-based sample clean-up and voltage assisted liquid desorption ESI-MS/MS (VAL DESI-MS/MS) to detect multiple targeted compounds of clinical interest. Adenosine monophosphate (AMP), adenosine diphosphate (ADP), and adenosine triphosphate (ATP) were selected as model analytes. Simultaneous quantification of these compounds in human serum samples was demonstrated. For all the three compounds, linear calibration curves were obtained in a concentration range from 0.20 to 20.0 μmol/L with r2 values ≥ 0.996. Limits of detection were 0.019, 0.015, and 0.011 μmol/L for AMP, ADP, and ATP, respectively. Recovery was found in the range from 96.5% to 103.5% at spiking concentrations of 0.25 and 2.50 μmol/L. The results indicate that the proposed microfluidic mass spectrometric platform is robust and effective. It may have a potential in clinical analysis.
Collapse
|
13
|
Liu C, Li J, Chen H, Zare RN. Scale-up of microdroplet reactions by heated ultrasonic nebulization. Chem Sci 2019; 10:9367-9373. [PMID: 32110301 PMCID: PMC7017870 DOI: 10.1039/c9sc03701b] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Accepted: 08/19/2019] [Indexed: 12/24/2022] Open
Abstract
Dramatically higher rates for a variety of chemical reactions have been reported in microdroplets compared with those in the liquid bulk phase. However, the scale-up of microdroplet chemical synthesis has remained a major challenge to the practical application of microdroplet chemistry. Heated ultrasonic nebulization (HUN) was found as a new way for scaling up chemical synthesis in microdroplets. Four reactions were examined, a base-catalyzed Claisen-Schmidt condensation, an oximation reaction from a ketone, a two-phase oxidation reaction without the use of a phase-transfer-catalyst, and an Eschenmoser coupling reaction. These reactions show acceleration of one to three orders of magnitude (122, 23, 6536, and 62) in HUN microdroplets compared to the same reactions in bulk solution. Then, using the present method, the scale-up of the reactions was achieved at an isolated rate of 19 mg min-1 for the product of the Claisen-Schmidt condensation, 21 mg min-1 for the synthesis of benzophenone oxime from benzophenone, 31 mg min-1 for the synthesis of 4-methoxybenzaldehyde from 4-methoxybenzyl alcohol, and 40 mg min-1 for the enaminone product of the Eschenmoser coupling reaction.
Collapse
Affiliation(s)
- Chengyuan Liu
- Department of Chemistry , Fudan University , Shanghai 200438 , China .
| | - Jia Li
- Department of Chemistry , Fudan University , Shanghai 200438 , China .
| | - Hao Chen
- Department of Chemistry & Environmental Science , New Jersey Institute of Technology , Newark , NJ 07102 , USA
| | - Richard N Zare
- Department of Chemistry , Fudan University , Shanghai 200438 , China .
| |
Collapse
|
14
|
Rahman MM, Wu D, Chingin K, Xu W, Chen H. High ohmic resistor hyphenated gel loading tip nano-electrospray ionization source for mini mass spectrometer. Talanta 2019; 202:59-66. [PMID: 31171225 DOI: 10.1016/j.talanta.2019.04.052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 04/16/2019] [Accepted: 04/19/2019] [Indexed: 10/27/2022]
Abstract
The deployment of mini mass spectrometers on the field strongly demands efficient ionization sources that are easy-to-operate. Nano-electrospray (nESI) ion source has been widely used in the field of chemistry, biology, medicine, pharmaceutical industry, clinical assessment and forensic science. In this study, a high ohmic resistor hyphenated gel loading tip nESI source was coupled with our home developed mini mass spectrometer. This ionization source has the advantages of simple-in-design, disposable and low-in-cost, therefore it could be frequently used for analysis of aqueous samples without leading to cross contamination. Performances of the gel loading tip nESI emitter were similar to pulled glass capillary, and highly compatible for the analysis of biomolecule in aqueous solution. Different peptide and small molecules have been confirmed with a continuous atmospheric pressure-interfaced (CAPI) mini mass spectrometer. The corona discharge, which was usually observed at nESI emitter tip under high aqueous solvent conditions, resulting in low ion intensity, has been successfully quenched using a 10 GΩ resistor in both a pulled glass capillary and a gel loading tip as nESI emitter in this study. Compared with conventional ESI, the metal wire assisted gel loading tip facilitated loading and direct analysis of biological samples without sample pretreatment.
Collapse
Affiliation(s)
- Md Matiur Rahman
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, China.
| | - Debo Wu
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, China
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, China
| | - Wei Xu
- College of Information of Science, Shenzhen University, Shenzhen, 518060, China; School of Life Science, Beijing Institute of Technology, Beijing, 100081, China.
| | - Huanwen Chen
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, 330013, China
| |
Collapse
|
15
|
Rahman MM, Chingin K, Chen H. Online desalting and sequential formation of analyte ions for mass spectrometry characterization of untreated biological samples. Chem Commun (Camb) 2019; 55:9188-9191. [DOI: 10.1039/c9cc04705k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Current-limited high voltage polarity reversing nanoelectrospray ionization allows online separation of intrinsic metal ions in complex biological samples, resulting in the generation of protonated analytes without interference from salt cations.
Collapse
Affiliation(s)
- Md. Matiur Rahman
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| | - Huanwen Chen
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| |
Collapse
|
16
|
Chen TY, Wu ML, Chen YC. Ultrasonication-assisted spray ionization-based micro-reactors for online monitoring of fast chemical reactions by mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:26-34. [PMID: 30407688 DOI: 10.1002/jms.4307] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 10/25/2018] [Accepted: 11/01/2018] [Indexed: 06/08/2023]
Abstract
Microfluidics can be used to handle relatively small volumes of samples and to conduct reactions in microliter-sized volumes. Electrospray ionization can couple microfluidics with mass spectrometry (MS) to monitor chemical reactions online. However, fabricating microfluidic chips is time-consuming. We herein propose the use of a micro-reactor that is sustained by two capillaries and an ultrasonicator. The inlets of the capillaries were individually immersed to two different sample vials that were subjected to the ultrasonicator. The tapered outlets of the two capillaries were placed cross with an angle of ~60° close to the inlet of the mass spectrometer to fuse the eluents. On the basis of capillary action and ultrasonication, the samples from the two capillaries can be continuously directed to the capillary outlets and fuse simultaneously to generate gas phase ions for MS analysis through ultrasonication-assisted spray ionization (UASI). Any electric contact applied on the capillaries is not required. Nevertheless, UASI spray derived from the eluents can readily occur in front of the mass spectrometer. That is, a micro-reactor was created from the fusing of the eluent containing different reactants from these two UASI capillaries, allowing reactions to be conducted in situ. The solvent in the fused droplets was evaporated quickly, and the product ions could be immediately observed by MS because of the extreme rise in the concentration of the reactants. For proof of concept, pyrazole synthesis reaction and cortisone derivatization by Girard T reagent were selected as the model reactions. The results demonstrated the feasibility of using UASI-based micro-reactor for online MS analysis to detect reaction intermediates and products.
Collapse
Affiliation(s)
- Te-Yu Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu, 300, Taiwan
| | - Min-Li Wu
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu, 300, Taiwan
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu, 300, Taiwan
| |
Collapse
|
17
|
ZHANG XL, ZHANG H, WANG XC, HUANG KK, WANG D, CHEN HW. Advances in Ambient Ionization for Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2018. [DOI: 10.1016/s1872-2040(18)61122-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
18
|
Sundberg BN, Lagalante AF. Coaxial Electrospray Ionization for the Study of Rapid In-source Chemistry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:2023-2029. [PMID: 29949060 DOI: 10.1007/s13361-018-2004-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 05/25/2018] [Accepted: 05/31/2018] [Indexed: 06/08/2023]
Abstract
Coaxial electrospray has been used effectively for several dual-emitter applications, but has not been utilized for the study of rapid in-source chemistry. In this paper, we report the fabrication of a coaxial, micro-volume dual-emitter through the modification of a manufacturer's standard electrospray probe. This modification creates rapid mixing inside the Taylor cone and the ability to manipulate fast reactions using a variety of solvents and analytes. We demonstrate its potential as a low-cost, dual-emitter assembly for diverse applications through three examples: relative ionization in a biphasic electrospray, hydrogen-deuterium exchange, and protein supercharging. Graphical Abstract.
Collapse
Affiliation(s)
- Brynn N Sundberg
- Department of Chemistry, Villanova University, 800 Lancaster Avenue, Villanova, PA, 19085, USA
| | - Anthony F Lagalante
- Department of Chemistry, Villanova University, 800 Lancaster Avenue, Villanova, PA, 19085, USA.
| |
Collapse
|
19
|
Wilson AD. Application of Electronic-Nose Technologies and VOC-Biomarkers for the Noninvasive Early Diagnosis of Gastrointestinal Diseases †. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2613. [PMID: 30096939 PMCID: PMC6111575 DOI: 10.3390/s18082613] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 08/03/2018] [Accepted: 08/04/2018] [Indexed: 12/13/2022]
Abstract
Conventional methods utilized for clinical diagnosis of gastrointestinal (GI) diseases have employed invasive medical procedures that cause stress, anxiety and pain to patients. These methods are often expensive, time-consuming, and require sophisticated chemical-analysis instruments and advanced modeling procedures to achieve diagnostic interpretations. This paper reviews recent applications of simpler, electronic-nose (e-nose) devices for the noninvasive early diagnosis of a wide range of GI diseases by collective analysis of headspace volatile organic compound (VOC)-metabolites from clinical samples to produce disease-specific aroma signatures (VOC profiles). A different "metabolomics" approach to GI disease diagnostics, involving identifications and quantifications of disease VOC-metabolites, are compared to the electronic-nose approach based on diagnostic costs, accuracy, advantages and disadvantages. The importance of changes in gut microbiome composition that result from disease are discussed relative to effects on disease detection. A new diagnostic approach, which combines the use of e-nose instruments for early rapid prophylactic disease-screenings with targeted identification of known disease biomarkers, is proposed to yield cheaper, quicker and more dependable diagnostic results. Some priority future research needs and coordination for bringing e-nose instruments into routine clinical practice are summarized.
Collapse
Affiliation(s)
- Alphus Dan Wilson
- Pathology Department, Southern Hardwoods Laboratory, Center for Bottomland Hardwoods Research, Southern Research Station, USDA Forest Service, 432 Stoneville Road, Stoneville, MS 38776, USA.
| |
Collapse
|
20
|
Yan X, Bain RM, Cooks RG. Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry. Angew Chem Int Ed Engl 2018; 55:12960-12972. [PMID: 27530279 DOI: 10.1002/anie.201602270] [Citation(s) in RCA: 267] [Impact Index Per Article: 44.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Indexed: 11/10/2022]
Abstract
The striking finding that reaction acceleration occurs in confined-volume solutions sets up an apparent conundrum: Microdroplets formed by spray ionization can be used to monitor the course of bulk-phase reactions and also to accelerate reactions between the reagents in such a reaction. This Minireview introduces droplet and thin-film acceleration phenomena and summarizes recent methods applied to study accelerated reactions in confined-volume, high-surface-area solutions. Conditions that dictate either simple monitoring or acceleration are reconciled in the occurrence of discontinuous and complete desolvation as the endpoint of droplet evolution. The contrasting features of microdroplet and bulk-solution reactions are described together with possible mechanisms that drive reaction acceleration in microdroplets. Current applications of droplet microreactors are noted as is reaction acceleration in confined volumes and possible future scale-up.
Collapse
Affiliation(s)
- Xin Yan
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - Ryan M Bain
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA.
| |
Collapse
|
21
|
Wang H, Yong G, Brown SL, Lee HE, Zenaidee MA, Supuran CT, Donald WA. Supercharging protein ions in native mass spectrometry using theta capillary nanoelectrospray ionization mass spectrometry and cyclic alkylcarbonates. Anal Chim Acta 2018; 1003:1-9. [DOI: 10.1016/j.aca.2017.11.075] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 11/22/2017] [Accepted: 11/25/2017] [Indexed: 12/27/2022]
|
22
|
Multi-channel microfluidic chip coupling with mass spectrometry for simultaneous electro-sprays and extraction. Sci Rep 2017; 7:17389. [PMID: 29234133 PMCID: PMC5727197 DOI: 10.1038/s41598-017-17764-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Accepted: 11/30/2017] [Indexed: 02/07/2023] Open
Abstract
Considering the advantages and research status of microfluidic chip coupling with mass spectrometry (MS), a microfluidic chip-based multi-channel ionization (MCMCI) for the extraction of untreated compounds in complex matrices without sample pretreatments was developed. Quantitative analysis of human urine spiked with various rhodamine B concentrations was also performed, and good linearity was obtained. Comparing to the macro ionization device, MCMCI significantly improved the integration of ionization source, simplified the operation of such a device, and greatly increased the signal intensity with much lower gas pressure. Comparison of our MCMCI with two and three gas channels indicated that the liquid–liquid extraction process before spraying and after spraying produced similar MS results. Moreover, this MCMCI with three gas channels also implemented simultaneous dual sprays with high DC voltages, the interference of two samples was minor and ion suppression effect was drastically alleviated. Such advantages may easily enable internal calibration for accurate mass measurement. Furthermore, dual extraction can be implemented by integrating such multi-spray configuration, which can improve the extracted signal intensity and sensitivity. These technologies open up new avenues for the application of microfluidic chip coupling with MS.
Collapse
|
23
|
Li X, Xu R, Wei X, Hu H, Zhao S, Liu YM. Direct Analysis of Biofluids by Mass Spectrometry with Microfluidic Voltage-Assisted Liquid Desorption Electrospray Ionization. Anal Chem 2017; 89:12014-12022. [PMID: 29065681 DOI: 10.1021/acs.analchem.7b02398] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Signal suppression by sample matrix in direct electrospray ionization-mass spectrometric (ESI-MS) analysis hampers its clinical and biomedical applications. We report herein the development of a microfluidic voltage-assisted liquid desorption electrospray ionization (VAL-DESI) source to overcome this limitation. Liquid DESI is achieved for the first time in a microfluidic format. Direct analysis of urine, serum, and cell lysate samples by using the proposed microfluidic VAL-DESI-MS/MS method to detect chemical compounds of biomedical interest, including nucleosides, monoamines, amino acids, and peptides is demonstrated. Analyzing a set of urine samples spiked with dihydroxyphenylalanine (DOPA) showed that the assay had a linear calibration curve with r2 value of 0.997 and a limit of detection of 0.055 μM DOPA. The method was applied to simultaneous quantification of nucleosides, that is, cytidine, adenosine, uridine, thymidine, and guanosine in cell lysates using 8-bromoadenosine as internal standard. Adenosine was found most abundant at 26.5 ± 0.57 nmol/106 cells, while thymidine was least at 3.1 ± 0.31 nmol/106 cells. Interestingly, the ratio of adenosine to deoxyadenosine varied significantly from human red blood cells (1.07 ± 0.06) to cancerous cells, including lymphoblast TK6 (0.52 ± 0.02), skin melanoma C32 (0.82 ± 0.04), and promyelocytic leukemia NB4 cells (0.38 ± 0.06). These results suggest that the VAL-DESI-MS/MS technique has a good potential in direct analysis of biofluids. Further, because of the simplicity in its design and operation, the proposed microfluidic liquid DESI source can be fabricated as a disposable device for point-of-care measurements.
Collapse
Affiliation(s)
- Xiangtang Li
- Department of Chemistry and Biochemistry, Jackson State University , Jackson, Mississippi 39217, United States
| | - Rui Xu
- Department of Chemistry and Biochemistry, Jackson State University , Jackson, Mississippi 39217, United States
| | - Xin Wei
- Zhongnan Hospital of Wuhan University , Wuhan 430071, China
| | - Hankun Hu
- Zhongnan Hospital of Wuhan University , Wuhan 430071, China
| | - Shulin Zhao
- State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Normal University , Guilin 541004, China
| | - Yi-Ming Liu
- Department of Chemistry and Biochemistry, Jackson State University , Jackson, Mississippi 39217, United States
| |
Collapse
|
24
|
IR-MALDESI method optimization based on time-resolved measurement of ion yields. Anal Bioanal Chem 2017; 410:963-970. [PMID: 28852816 DOI: 10.1007/s00216-017-0585-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 08/11/2017] [Indexed: 12/28/2022]
Abstract
In the field of mass spectrometry imaging, typical experiments involve ionization directly from complex samples with no pre-ionization separation, relying on high resolving power mass analyzers to separate ions of interest. When an ion trapping step is involved in the analysis, the dynamic range of the analysis may be limited by the capacity of the ion trap, which is easily exceeded. To minimize collection of undesired ambient species while maximizing collection of analyte signal, accurate timing between ion generation and collection is a requirement. Here, a method for achieving synchronicity between infrared laser ablation and ion collection on a Q Exactive Plus mass spectrometer is described and demonstrated through measurement of ion accumulation at fixed time points following a laser ablation event with electrospray post-ionization of ablated material. In a model imaging experiment using infrared matrix-assisted laser desorption electrospray ionization, fixing the injection time at the minimum duration required to capture all ions generated by the last laser pulse in a sequence is shown to maximize target ion abundances. Using optimized timing is shown to yield a doubling or better of useful signal compared to previously used parameters. Graphical abstract Illustration of the effects of signal optimization on data quality for a single lipid species (cholesterol) measured from mouse liver tissue.
Collapse
|
25
|
Usmanov DT, Hiraoka K, Wada H, Matsumura M, Sanada-Morimura S, Nonami H, Yamabe S. Non-proximate mass spectrometry using a heated 1-m long PTFE tube and an air-tight APCI ion source. Anal Chim Acta 2017; 973:59-67. [DOI: 10.1016/j.aca.2017.03.044] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2017] [Revised: 03/19/2017] [Accepted: 03/24/2017] [Indexed: 11/16/2022]
|
26
|
Meher AK, Chen YC. Electrospray Modifications for Advancing Mass Spectrometric Analysis. ACTA ACUST UNITED AC 2017; 6:S0057. [PMID: 28573082 DOI: 10.5702/massspectrometry.s0057] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 12/30/2016] [Indexed: 11/23/2022]
Abstract
Generation of analyte ions in gas phase is a primary requirement for mass spectrometric analysis. One of the ionization techniques that can be used to generate gas phase ions is electrospray ionization (ESI). ESI is a soft ionization method that can be used to analyze analytes ranging from small organics to large biomolecules. Numerous ionization techniques derived from ESI have been reported in the past two decades. These ion sources are aimed to achieve simplicity and ease of operation. Many of these ionization methods allow the flexibility for elimination or minimization of sample preparation steps prior to mass spectrometric analysis. Such ion sources have opened up new possibilities for taking scientific challenges, which might be limited by the conventional ESI technique. Thus, the number of ESI variants continues to increase. This review provides an overview of ionization techniques based on the use of electrospray reported in recent years. Also, a brief discussion on the instrumentation, underlying processes, and selected applications is also presented.
Collapse
Affiliation(s)
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University
| |
Collapse
|
27
|
Cheng SC, Chen SH, Shiea J. Desorption Flame-Induced Atmospheric Pressure Chemical Ionization Mass Spectrometry for Rapid Real-World Sample Analysis. ACTA ACUST UNITED AC 2017; 6:S0065. [PMID: 28573084 DOI: 10.5702/massspectrometry.s0065] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 01/17/2017] [Indexed: 11/23/2022]
Abstract
Flame-induced atmospheric pressure chemical ionization (FAPCI) is a solvent and high voltage-free APCI technique. It uses a flame to produce charged species that reacts with analytes for ionization, and generates intact molecular ions from organic compounds with minimal fragmentation. In this study, desorption FAPCI/MS was developed to rapidly characterize thermally stable organic compounds in liquid, cream, and solid states. Liquid samples were introduced into the ion source through a heated nebulizer, and the analytes formed in the heated nebulizer reacted with charged species in the source. For cream and solid sample analysis, the samples were positioned near the flame of the FAPCI source for thermal desorption and ionization. This approach provided a useful method to directly characterize samples with minimal pretreatment. Standards and real-world samples, such as drug tablets, ointment, and toy were analyzed to demonstrate the capability of desorption FAPCI/MS for rapid organic compound analysis.
Collapse
Affiliation(s)
- Sy-Chyi Cheng
- Department of Chemistry, National Sun Yat-Sen University
| | - Shih-His Chen
- Department of Chemistry, National Sun Yat-Sen University
| | - Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University.,Department of Medicinal and Applied Chemistry, Kaohsiung Medical University
| |
Collapse
|
28
|
Investigating the structural transitions of proteins during dissolution by mass spectrometry. Talanta 2017; 164:418-426. [DOI: 10.1016/j.talanta.2016.11.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 11/07/2016] [Accepted: 11/09/2016] [Indexed: 11/17/2022]
|
29
|
Ekelöf M, McMurtrie EK, Nazari M, Johanningsmeier SD, Muddiman DC. Direct Analysis of Triterpenes from High-Salt Fermented Cucumbers Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:370-375. [PMID: 27848143 DOI: 10.1007/s13361-016-1541-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 10/17/2016] [Accepted: 10/20/2016] [Indexed: 05/11/2023]
Abstract
High-salt samples present a challenge to mass spectrometry (MS) analysis, particularly when electrospray ionization (ESI) is used, requiring extensive sample preparation steps such as desalting, extraction, and purification. In this study, infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) coupled to a Q Exactive Plus mass spectrometer was used to directly analyze 50-μm thick slices of cucumber fermented and stored in 1 M sodium chloride brine. From the several hundred unique substances observed, three triterpenoid lipids produced by cucumbers, β-sitosterol, stigmasterol, and lupeol, were putatively identified based on exact mass and selected for structural analysis. The spatial distribution of the lipids were imaged, and the putative assignments were confirmed by tandem mass spectrometry performed directly on the same cucumber, demonstrating the capacity of the technique to deliver confident identifications from highly complex samples in molar concentrations of salt without the need for sample preparation. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Måns Ekelöf
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Erin K McMurtrie
- Department of Food, Bioprocessing, and Nutrition Sciences, North Carolina State University, Raleigh, NC, 27695, USA
| | - Milad Nazari
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Suzanne D Johanningsmeier
- Department of Food, Bioprocessing, and Nutrition Sciences, North Carolina State University, Raleigh, NC, 27695, USA
- Food Science Research Unit, USDA Agricultural Research Service, Raleigh, NC, 27695, USA
| | - David C Muddiman
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
30
|
Lento C, Wilson DJ. Unravelling the mysteries of sub-second biochemical processes using time-resolved mass spectrometry. Analyst 2017; 142:1640-1653. [DOI: 10.1039/c7an00338b] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Many important chemical and biochemical phenomena proceed on sub-second time scales.
Collapse
Affiliation(s)
| | - Derek J. Wilson
- Department of Chemistry
- York University
- Toronto
- Canada
- Centre for Research of Biomolecular Interactions
| |
Collapse
|
31
|
Ambient Desorption/Ionization. Mass Spectrom (Tokyo) 2017. [DOI: 10.1007/978-3-319-54398-7_13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
32
|
Yan X, Bain RM, Cooks RG. Organische Reaktionen in Mikrotröpfchen: Analyse von Reaktionsbeschleunigungen durch Massenspektrometrie. Angew Chem Int Ed Engl 2016. [DOI: 10.1002/ange.201602270] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Xin Yan
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| | - Ryan M. Bain
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| | - R. Graham Cooks
- Department of Chemistry Purdue University 560 Oval Drive West Lafayette IN 47907 USA
| |
Collapse
|
33
|
Fisher CM, Hilger RT, Zhao F, McLuckey SA. Electroosmotically driven solution mixing in borosilicate theta glass nESI emitters. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:1063-1070. [PMID: 28338258 DOI: 10.1002/jms.3620] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Revised: 05/19/2015] [Accepted: 05/22/2015] [Indexed: 06/06/2023]
Abstract
The use of borosilicate theta glass capillaries as nanoelectrospray ionization emitters has recently been demonstrated as a method for mixing two solutions as they are sprayed into the mass spectrometer for analysis. All previous experiments resulted in a solution mixing timescale limited to the time the analytes spend in the Taylor cone and subsequent droplets (i.e. sub-millisecond timescale). In an effort to extend the solution mixing timescale to the milliseconds regime, we demonstrate that solution can be moved from one channel of the theta tip to the opposite channel via electroosmosis by applying a potential difference between the two wire electrodes inserted into each channel of the theta tip. First, we establish that electroosmosis is responsible for solution movement using fluorescence microscopy to track fluorescent tracer dyes. We then demonstrate the utility of this technique in varying the extent of denaturation of holomyoglobin to apomyoglobin on the millisecond timescale just prior to analysis by mass spectrometry. Finally, we induce additional turbulence for better mixing by applying a square wave potential to one of the wire electrodes while holding the opposite wire at a constant voltage between the low and high potentials of the square wave. This experiment was found to provide nearly complete mixing after a single cycle of the square wave. The use of electroosmosis significantly expands the flexibility of theta tips for altering solutions prior to nESI without the need for off-line sample manipulation. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Christine M Fisher
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Ryan T Hilger
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Feifei Zhao
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| | - Scott A McLuckey
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907-2084, USA
| |
Collapse
|
34
|
Hsieh KT, Liu PH, Urban PL. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples. Anal Chim Acta 2015; 894:35-43. [DOI: 10.1016/j.aca.2015.08.045] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Revised: 08/17/2015] [Accepted: 08/23/2015] [Indexed: 01/23/2023]
|
35
|
Zhang M, Lin F, Xu J, Xu W. Membrane electrospray ionization for direct ultrasensitive biomarker quantitation in biofluids using mass spectrometry. Anal Chem 2015; 87:3123-8. [PMID: 25728048 DOI: 10.1021/acs.analchem.5b00467] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The ability of rapid biomarker quantitation in raw biological samples would expand the application of mass spectrometry in clinical diagnosis. Up until now, the conventional chromatography-mass spectrometry method is time-consuming in both sample preparation and chromatography separation processes, while ambient ionization methods normally suffer from sensitivity. The membrane electrospray ionization (MESI) introduced in this study could not only achieve sensitive biomolecule quantitation, but also minimize the sample handling process. As a unique feature of MESI, both vertical and horizontal chemical separations could be achieved in real-time. With the capability of mass-selectively minimizing matrix effects from salts, small molecules, and macromolecules, ultrasensitive detection of cytochrome C (>500-fold sensitivity improvement) in raw urine samples was demonstrated in less than 20 min.
Collapse
Affiliation(s)
- Mei Zhang
- †National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China, 102206.,‡State Key Laboratory for Infectious Disease Prevention and Control, Beijing, China, 102206.,§Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China, 310003
| | - Fankai Lin
- ⊥School of Life Science, Beijing Institute of Technology, Beijing, China, 100081
| | - Jianguo Xu
- †National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China, 102206.,‡State Key Laboratory for Infectious Disease Prevention and Control, Beijing, China, 102206.,§Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China, 310003
| | - Wei Xu
- ⊥School of Life Science, Beijing Institute of Technology, Beijing, China, 100081
| |
Collapse
|
36
|
Metwally H, McAllister RG, Konermann L. Exploring the Mechanism of Salt-Induced Signal Suppression in Protein Electrospray Mass Spectrometry Using Experiments and Molecular Dynamics Simulations. Anal Chem 2015; 87:2434-42. [DOI: 10.1021/ac5044016] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Haidy Metwally
- Department
of Chemistry, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| | - Robert G. McAllister
- Department
of Chemistry, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| | - Lars Konermann
- Department
of Chemistry, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| |
Collapse
|
37
|
Cheng SC, Jhang SS, Huang MZ, Shiea J. Simultaneous detection of polar and nonpolar compounds by ambient mass spectrometry with a dual electrospray and atmospheric pressure chemical ionization source. Anal Chem 2015; 87:1743-8. [PMID: 25562530 DOI: 10.1021/ac503625m] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
A dual ionization source combining electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was developed to simultaneously ionize both polar and nonpolar compounds. The source was constructed by inserting a fused silica capillary into a stainless steel column enclosed in a glass tube. A high dc voltage was applied to a methanol solution flowing in the fused silica capillary to generate an ESI plume at the capillary tip. A high ac voltage was applied to a ring electrode attached to the glass tube to generate plasma from the nitrogen gas flowing between the glass tube and the stainless steel column. The concentric arrangement of the ESI plume and the APCI plasma in the source ensured that analytes entering the ionization region interacted with both ESI and APCI primary ion species generated in the source. Because the high voltages required for ESI and APCI were independently applied and controlled, the dual ion source could be operated in ESI-only, APCI-only, or ESI+APCI modes. Analytes were introduced into the ESI and/or APCI plumes by irradiating sample surfaces with a continuous-wavelength laser or a pulsed laser beam. Analyte ions could also be produced by directing the dual ESI+APCI source toward sample surfaces for desorption and ionization. The ionization mechanisms involved in the dual ion source include Penning ionization, ion molecule reactions, and fused-droplet electrospray ionization. Standards of polycyclic aromatic hydrocarbons, angiotensin I, lidocaine, ferrocene, diesel, and rosemary oils were used for testing. Protonated analyte ions were detected in ESI-only mode, radical cations were detected in APCI-only mode, and both types of ions were detected in ESI+APCI mode.
Collapse
Affiliation(s)
- Sy-Chyi Cheng
- Department of Chemistry, National Sun Yat-Sen University , 70 Lienhai Road, Kaohsiung 80424, Taiwan
| | | | | | | |
Collapse
|
38
|
|
39
|
Mortensen D, Williams ER. Theta-glass capillaries in electrospray ionization: rapid mixing and short droplet lifetimes. Anal Chem 2014; 86:9315-21. [PMID: 25160559 PMCID: PMC4165459 DOI: 10.1021/ac502545r] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Accepted: 08/26/2014] [Indexed: 02/06/2023]
Abstract
Double-barrel wire-in-a-capillary electrospray emitters prepared from theta-glass capillaries were used to mix solutions during the electrospray process. The relative flow rate of each barrel was continuously monitored with internal standards. The complexation reaction of 18-crown-6 and K(+), introduced from opposite barrels, reaches equilibrium during the electrospray process, suggesting that complete mixing also occurs. A simplified diffusion model suggests that mixing occurs in less than a millisecond, and contributions of turbulence, estimated from times of coalescing ballistic microdroplets, suggest that complete mixing occurs within a few microseconds. This mixing time is 2 orders of magnitude less than in any mixer previously coupled to a mass spectrometer. The reduction of 2,6-dichloroindophenol by l-ascorbic acid was performed using the theta-glass emitters and monitored using mass spectrometry. On the basis of the rate constant of this reaction in bulk solution, an apparent reaction time of 274 ± 60 μs was obtained. This reaction time is an upper limit to the droplet lifetime because the surface area to volume ratio and the concentration of reagents increase as the droplet evaporates and some product formation occurs in the Taylor cone prior to droplet formation. On the basis of increases in reaction rates measured by others in droplets compared to rates in bulk solution, the true droplet lifetime is likely 1-3 orders of magnitude less than the upper limit, i.e., between 27 μs and 270 ns. The rapid mixing and short droplet lifetime achieved in these experiments should enable the monitoring of many different fast reactions using mass spectrometry.
Collapse
Affiliation(s)
- Daniel
N. Mortensen
- Department
of Chemistry, University of California, Berkeley, California 94720-1460, United States
| | - Evan R. Williams
- Department
of Chemistry, University of California, Berkeley, California 94720-1460, United States
| |
Collapse
|
40
|
Wang H, So PK, Ng TT, Yao ZP. Rapid analysis of raw solution samples by C18 pipette-tip electrospray ionization mass spectrometry. Anal Chim Acta 2014; 844:1-7. [DOI: 10.1016/j.aca.2014.07.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2014] [Revised: 07/10/2014] [Accepted: 07/12/2014] [Indexed: 12/22/2022]
|
41
|
Zhang JT, Wang HY, Zhu W, Cai TT, Guo YL. Solvent-Assisted Electrospray Ionization for Direct Analysis of Various Compounds (Complex) from Low/Nonpolar Solvents and Eluents. Anal Chem 2014; 86:8937-42. [DOI: 10.1021/ac502656a] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Jun-Ting Zhang
- National Center for Organic
Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, People’s Republic of China
| | - Hao-Yang Wang
- National Center for Organic
Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, People’s Republic of China
| | - Wei Zhu
- National Center for Organic
Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, People’s Republic of China
| | - Ting-Ting Cai
- National Center for Organic
Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, People’s Republic of China
| | - Yin-Long Guo
- National Center for Organic
Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, People’s Republic of China
| |
Collapse
|
42
|
Fisher CM, Kharlamova A, McLuckey SA. Affecting Protein Charge State Distributions in Nano-Electrospray Ionization via In-Spray Solution Mixing Using Theta Capillaries. Anal Chem 2014; 86:4581-8. [PMID: 24702054 DOI: 10.1021/ac500721r] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Christine M. Fisher
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907-2084, United States
| | - Anastasia Kharlamova
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907-2084, United States
| | - Scott A. McLuckey
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907-2084, United States
| |
Collapse
|
43
|
Mandal MK, Yoshimura K, Saha S, Yu Z, Takeda S, Hiraoka K. Biomolecular Analysis and Biological Tissue Diagnostics by Electrospray Ionization with a Metal Wire Inserted Gel-Loading Tip. Anal Chem 2013; 86:987-92. [DOI: 10.1021/ac403261s] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Mridul Kanti Mandal
- Clean Energy Research
Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Kentaro Yoshimura
- Department
of Anatomy and Cell Biology, Interdisciplinary Graduate
School of Medicine and Engineering, University of Yamanashi, Chuo, Yamanashi 409-3898, Japan
| | - Subhrakanti Saha
- Clean Energy Research
Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Zhan Yu
- Clean Energy Research
Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan
- School of Chemical
and Life Sciences, Shenyang Normal University, Shenyang 110034, China
| | - Sen Takeda
- Department
of Anatomy and Cell Biology, Interdisciplinary Graduate
School of Medicine and Engineering, University of Yamanashi, Chuo, Yamanashi 409-3898, Japan
| | - Kenzo Hiraoka
- Clean Energy Research
Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan
| |
Collapse
|
44
|
Cho YT, Huang MZ, Wu SY, Hou MF, Li J, Shiea J. Using electrospray laser desorption ionization mass spectrometry to rapidly examine the integrity of proteins stored in various solutions. Anal Bioanal Chem 2013; 406:577-86. [PMID: 24343451 DOI: 10.1007/s00216-013-7491-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2013] [Revised: 11/05/2013] [Accepted: 11/06/2013] [Indexed: 11/30/2022]
Abstract
Electrospray laser desorption ionization mass spectrometry (ELDI/MS) allows the rapid desorption and ionization of proteins from solutions under ambient conditions. In this study, we have demonstrated the use of ELDI/MS to efficiently examine the integrity of the proteins stored in various solutions before they were further used for other biochemical tests. The protein standards were prepared in the solutions containing buffers, organic salts, inorganic salts, strong acid, strong base, and organic solvents, respectively, to simulate those collected from solvent extraction, filtration, dialysis, or chromatographic separation. Other than the deposit of a drop of the sample solution on the metallic sample plate in an ELDI source, no additional sample pretreatment is needed. The sample drop was then irradiated with a pulsed laser; this led to desorption of the analyte molecules, which subsequently entered the ESI plume to undergo post-ionization. Because adjustment of the composition of the sample solution is unnecessary, this technique appears to be useful for rapidly evaluating the integrity of proteins after storage or prior to further biochemical treatment. In addition, when using acid-free and low-organic-solvent ESI solutions for ELDI/MS analysis, the native conformations of the proteins in solution could be detected.
Collapse
Affiliation(s)
- Yi-Tzu Cho
- Department of Cosmetic Applications and Management, Yuh-Ing Junior College of Health Care & Management, No.15 Lane 420 Dachang 2nd Rd, Kaohsiung 807, Taiwan,
| | | | | | | | | | | |
Collapse
|
45
|
|
46
|
Hsieh CH, Meher AK, Chen YC. Automatic sampling and analysis of organics and biomolecules by capillary action-supported contactless atmospheric pressure ionization mass spectrometry. PLoS One 2013; 8:e66292. [PMID: 23762484 PMCID: PMC3675195 DOI: 10.1371/journal.pone.0066292] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2012] [Accepted: 05/09/2013] [Indexed: 11/18/2022] Open
Abstract
Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.
Collapse
Affiliation(s)
- Cheng-Huan Hsieh
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu, Taiwan
| | - Anil Kumar Meher
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu, Taiwan
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu, Taiwan
- * E-mail:
| |
Collapse
|
47
|
Rahman MM, Chen LC, Hiraoka K. Development of high-pressure probe electrospray ionization for aqueous solution. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:68-74. [PMID: 23239318 DOI: 10.1002/rcm.6427] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2012] [Revised: 09/26/2012] [Accepted: 09/29/2012] [Indexed: 06/01/2023]
Abstract
RATIONALE Probe electrospray ionization (PESI) is a recently developed method that uses a sharp solid needle as electrospray emitter and the sample is loaded to the needle tip by repetitive movement of the needle probe. This method has been previously used for the analysis of sample with high salt concentration and real-world samples without sample pretreatment. Although PESI is also applicable to aqueous solution, the ion signal stability and reproducibility were not satisfactory due to the spontaneous occurrence of corona discharge taking place on the metallic needle tip. METHODS In the previous version of PESI, the ionization was performed under an open environment, thus ambient condition such as humidity and the presence of environmental contaminant also affected the performance of PESI. In this paper, we report a modified version of PESI in which the electrospray and the desolvation of charged droplets are performed inside an enclosed chamber which is pressurized to >1 atm with dry air. RESULTS Under a super atmospheric condition, the dielectric strength of the ambient gas was enhanced and stable electrospray could to be initiated without the occurrence of corona discharge even for liquid sample with high surface tension such as pure water. A comparative study of atmospheric-pressure PESI and high-pressure PESI (HP-PESI) had been performed to demonstrate the improvement of PESI in sensitivity and signal stability for the detection analytes in aqueous solution. CONCLUSIONS HP-PESI offers a higher sensitivity and signal stability over PESI due to the absence of gaseous breakdown, better desolvation, and higher ion sampling rate by the mass spectrometer.
Collapse
Affiliation(s)
- Md Matiur Rahman
- Clean Energy Research Center, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi, 400-8511, Japan
| | | | | |
Collapse
|
48
|
Monge ME, Harris GA, Dwivedi P, Fernández FM. Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. Chem Rev 2013; 113:2269-308. [DOI: 10.1021/cr300309q] [Citation(s) in RCA: 404] [Impact Index Per Article: 36.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- María Eugenia Monge
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Glenn A. Harris
- Department
of Biochemistry and
the Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Prabha Dwivedi
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| |
Collapse
|
49
|
Zhu W, Yuan Y, Zhou P, Zeng L, Wang H, Tang L, Guo B, Chen B. The expanding role of electrospray ionization mass spectrometry for probing reactive intermediates in solution. Molecules 2012; 17:11507-37. [PMID: 23018925 PMCID: PMC6268401 DOI: 10.3390/molecules171011507] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2012] [Revised: 08/29/2012] [Accepted: 09/05/2012] [Indexed: 12/31/2022] Open
Abstract
Within the past decade, electrospray ionization mass spectrometry (ESI-MS) has rapidly occupied a prominent position for liquid-phase mechanistic studies due to its intrinsic advantages allowing for efficient "fishing" (rapid, sensitive, specific and simultaneous detection/identification) of multiple intermediates and products directly from a "real-world" solution. In this review we attempt to offer a comprehensive overview of the ESI-MS-based methodologies and strategies developed up to date to study reactive species in reaction solutions. A full description of general issues involved with probing reacting species from complex (bio)chemical reaction systems is briefly covered, including the potential sources of reactive intermediate (metabolite) generation, analytical aspects and challenges, basic rudiments of ESI-MS and the state-of-the-art technology. The main purpose of the present review is to highlight the utility of ESI-MS and its expanding role in probing reactive intermediates from various reactions in solution, with special focus on current progress in ESI-MS-based approaches for improving throughput, testing reality and real-time detection by using newly developed MS instruments and emerging ionization sources (such as ambient ESI techniques). In addition, the limitations of modern ESI-MS in detecting intermediates in organic reactions is also discussed.
Collapse
Affiliation(s)
- Weitao Zhu
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| | - Yu Yuan
- School of Pharmaceutical Sciences, Central South University, 172 Tongzipo Road, Changsha 410013, China;
| | - Peng Zhou
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| | - Le Zeng
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| | - Hua Wang
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| | - Ling Tang
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| | - Bin Guo
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| | - Bo Chen
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), Hunan Normal University, 36 Lushan Road, Changsha 410081, China; (W.Z.); (P.Z.); (L.Z.); (H.W.); (L.T.); (B.C.)
| |
Collapse
|
50
|
Vidal-de-Miguel G, Macía M, Pinacho P, Blanco J. Low-sample flow secondary electrospray ionization: improving vapor ionization efficiency. Anal Chem 2012; 84:8475-9. [PMID: 22970991 DOI: 10.1021/ac3005378] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In secondary electrospray ionization (SESI) systems, gaseous analytes exposed to an elecrospray plume become ionized after charge is transferred from the charging electrosprayed particles to the sample species. Current SESI systems have shown a certain potential. However, their ionization efficiency is limited by space charge repulsion and by the high sample flows required to prevent vapor dilution. As a result, they have a poor conversion ratio of vapor into ions. We have developed and tested a new SESI configuration, termed low-flow SESI, that permits the reduction of the required sample flows. Although the ion to vapor concentration ratio is limited, the ionic flow to sample vapor flow ratio theoretically is not. The new ionizer is coupled to a planar differential mobility analyzer (DMA) and requires only 0.2 lpm of vapor sample flow to produce 3.5 lpm of ionic flow. The achieved ionization efficiency is 1/700 (one ion for every 700 molecules) for TNT and, thus, compared with previous SESI ionizers coupled with atmospheric pressure ionization-mass spectrometry (API-MS) (Mesonero, E.; Sillero, J. A.; Hernández, M.; Fernandez de la Mora, J. Philadelphia PA, 2009) has been improved by a large factor of at least 50-100 (our measurements indicate 70). The new ionizer coupled with the planar DMA and a triple quadrupole mass spectrometer (ABSciex API5000) requires only 20 fg (50 million molecules) to produce a discernible signal after mobility and MS(2) analysis.
Collapse
|