1
|
Iliescu FS, Poenar DP, Yu F, Ni M, Chan KH, Cima I, Taylor HK, Cima I, Iliescu C. Recent advances in microfluidic methods in cancer liquid biopsy. BIOMICROFLUIDICS 2019; 13:041503. [PMID: 31431816 PMCID: PMC6697033 DOI: 10.1063/1.5087690] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Accepted: 06/24/2019] [Indexed: 05/04/2023]
Abstract
Early cancer detection, its monitoring, and therapeutical prediction are highly valuable, though extremely challenging targets in oncology. Significant progress has been made recently, resulting in a group of devices and techniques that are now capable of successfully detecting, interpreting, and monitoring cancer biomarkers in body fluids. Precise information about malignancies can be obtained from liquid biopsies by isolating and analyzing circulating tumor cells (CTCs) or nucleic acids, tumor-derived vesicles or proteins, and metabolites. The current work provides a general overview of the latest on-chip technological developments for cancer liquid biopsy. Current challenges for their translation and their application in various clinical settings are discussed. Microfluidic solutions for each set of biomarkers are compared, and a global overview of the major trends and ongoing research challenges is given. A detailed analysis of the microfluidic isolation of CTCs with recent efforts that aimed at increasing purity and capture efficiency is provided as well. Although CTCs have been the focus of a vast microfluidic research effort as the key element for obtaining relevant information, important clinical insights can also be achieved from alternative biomarkers, such as classical protein biomarkers, exosomes, or circulating-free nucleic acids. Finally, while most work has been devoted to the analysis of blood-based biomarkers, we highlight the less explored potential of urine as an ideal source of molecular cancer biomarkers for point-of-care lab-on-chip devices.
Collapse
Affiliation(s)
- Florina S. Iliescu
- School of Applied Science, Republic Polytechnic, Singapore 738964, Singapore
| | - Daniel P. Poenar
- VALENS-Centre for Bio Devices and Signal Analysis, School of EEE, Nanyang Technological University, Singapore 639798, Singapore
| | - Fang Yu
- Singapore Institute of Manufacturing Technology, A*STAR, Singapore 138634, Singapore
| | - Ming Ni
- School of Biological Sciences and Engineering, Yachay Technological University, San Miguel de Urcuquí 100105, Ecuador
| | - Kiat Hwa Chan
- Division of Science, Yale-NUS College, Singapore 138527, Singapore
| | | | - Hayden K. Taylor
- Department of Mechanical Engineering, University of California, Berkeley, California 94720, USA
| | - Igor Cima
- DKFZ-Division of Translational Oncology/Neurooncology, German Cancer Consortium (DKTK), Heidelberg and University Hospital Essen, Essen 45147, Germany
| | | |
Collapse
|
2
|
Molina DE, Medina AS, Beyenal H, Ivory CF. Design and Finite Element Model of a Microfluidic Platform with Removable Electrodes for Electrochemical Analysis. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2019; 166:B125-B132. [PMID: 31341328 PMCID: PMC6656400 DOI: 10.1149/2.0891902jes] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
A microfluidic platform for hydrodynamic electrochemical analysis was developed, consisting of a poly(methyl methacrylate) chip and three removable electrodes, each housed in 1/16" OD polyether ether ketone tube which can be removed independently for polishing or replacement. The working electrode was a 100-μm diameter Pt microdisk, located flush with the upper face of a 150 μm × 20 μm × 3 cm microchannel, smaller than previously reported for these types of removable electrodes. A commercial leak-less reference electrode was utilized, and a coiled platinum wire was the counter electrode. The platform was evaluated electrochemically by oxidizing a potassium ferrocyanide solution at the working electrode, and a typical limiting current behavior was observed after running linear sweep voltammetry and chronoamperometry, with flow rates 1-6 μL/min. While microdisk channel electrodes have been simulated before using a finite difference method in an ideal 3D geometry, here we predict the limiting current using finite elements in COMSOL Multiphysics 5.3a, which allowed us to easily explore variations in the microchannel geometry that have not previously been considered in the literature. Experimental and simulated currents showed the same trend but differed by 41% in simulations of the ideal geometry, which improved when channel and electrode imperfections were included.
Collapse
Affiliation(s)
| | - Adan Schafer Medina
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99163, USA
| | | | - Cornelius F. Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99163, USA
| |
Collapse
|
3
|
Kecskemeti A, Gaspar A. Particle-based liquid chromatographic separations in microfluidic devices - A review. Anal Chim Acta 2018; 1021:1-19. [DOI: 10.1016/j.aca.2018.01.064] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 01/18/2018] [Accepted: 01/21/2018] [Indexed: 01/06/2023]
|
4
|
Burkhardt T, Kaufmann CM, Letzel T, Grassmann J. Enzymatic Assays Coupled with Mass Spectrometry with or without Embedded Liquid Chromatography. Chembiochem 2015; 16:1985-92. [DOI: 10.1002/cbic.201500325] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Indexed: 12/20/2022]
Affiliation(s)
- Therese Burkhardt
- Chair of Urban Water Systems Engineering; Technical University of Munich (TUM); Am Coulombwall 85748 Garching Germany
| | - Christine M. Kaufmann
- Chair of Urban Water Systems Engineering; Technical University of Munich (TUM); Am Coulombwall 85748 Garching Germany
| | - Thomas Letzel
- Chair of Urban Water Systems Engineering; Technical University of Munich (TUM); Am Coulombwall 85748 Garching Germany
| | - Johanna Grassmann
- Chair of Urban Water Systems Engineering; Technical University of Munich (TUM); Am Coulombwall 85748 Garching Germany
| |
Collapse
|
5
|
Gallagher R, Dillon L, Grimsley A, Murphy J, Samuelsson K, Douce D. The application of a new microfluidic device for the simultaneous identification and quantitation of midazolam metabolites obtained from a single micro-litre of chimeric mice blood. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:1293-1302. [PMID: 24760570 DOI: 10.1002/rcm.6902] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Revised: 03/12/2014] [Accepted: 03/21/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE Improvements in the design of low-flow highly sensitive chromatographic ion source interfaces allow the detection and characterisation of drugs and metabolites from smaller sample volumes. This in turn improves the ethical treatment of animals by reducing both the number of animals needed and the blood sampling volumes required. METHODS A new microfluidic device combining an ultra-high pressure liquid chromatography (UHPLC) analytical column with a nano-flow electrospray source is described. All microfluidic, gas and electrical connections are automatically engaged when the ceramic microfluidic device is inserted into the source enclosure. The system was used in conjunction with a hybrid quadrupole-time-of-flight mass spectrometer. RESULTS The improved sensitivity of the system is highlighted in its application in the quantification and qualification of midazolam and its metabolites detected in whole blood from chimeric and wild-type mice. Metabolite identification and full pharmacokinetic profiles were obtained from a single micro-litre of whole blood at each sampling time and significant pharmacokinetic differences were observed between the two types of mice. CONCLUSIONS Improvements in the enhanced ionisation efficiency from the microfluidic device in conjunction with nanoUHPLC/MS was sufficiently sensitive for the identification and quantification of midazolam metabolites from a single micro-litre of whole blood. Detection of metabolites not previously recorded from the chimeric mouse in vivo model was made.
Collapse
Affiliation(s)
- Richard Gallagher
- Oncology iMed DMPK, AstraZeneca UK Ltd., Alderley Park, Macclesfield, Cheshire, SK10 4TG, UK
| | | | | | | | | | | |
Collapse
|
6
|
Polini A, Prodanov L, Bhise NS, Manoharan V, Dokmeci MR, Khademhosseini A. Organs-on-a-chip: a new tool for drug discovery. Expert Opin Drug Discov 2014; 9:335-52. [PMID: 24620821 DOI: 10.1517/17460441.2014.886562] [Citation(s) in RCA: 143] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
INTRODUCTION The development of emerging in vitro tissue culture platforms can be useful for predicting human response to new compounds, which has been traditionally challenging in the field of drug discovery. Recently, several in vitro tissue-like microsystems, also known as 'organs-on-a-chip', have emerged to provide new tools for better evaluating the effects of various chemicals on human tissue. AREAS COVERED The aim of this article is to provide an overview of the organs-on-a-chip systems that have been recently developed. First, the authors introduce single-organ platforms, focusing on the most studied organs such as liver, heart, blood vessels and lung. Later, the authors briefly describe tumor-on-a-chip platforms and highlight their application for testing anti-cancer drugs. Finally, the article reports a few examples of other organs integrated in microfluidic chips along with preliminary multiple-organs-on-a-chip examples. The article also highlights key fabrication points as well as the main application areas of these devices. EXPERT OPINION This field is still at an early stage and major challenges need to be addressed prior to the embracement of these technologies by the pharmaceutical industry. To produce predictive drug screening platforms, several organs have to be integrated into a single microfluidic system representative of a humanoid. The routine production of metabolic biomarkers of the organ constructs, as well as their physical environment, have to be monitored prior to and during the delivery of compounds of interest to be able to translate the findings into useful discoveries.
Collapse
Affiliation(s)
- Alessandro Polini
- Brigham and Women's Hospital, Harvard Medical School, Division of Biomedical Engineering, Department of Medicine , Cambridge, MA 02139 , USA
| | | | | | | | | | | |
Collapse
|
7
|
Zhang S, Van Pelt CK. Chip-based nanoelectrospray mass spectrometry for protein characterization. Expert Rev Proteomics 2014; 1:449-68. [PMID: 15966841 DOI: 10.1586/14789450.1.4.449] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In the last several years, significant progress has been made in the development of microfluidic-based analytical technologies for proteomic and drug discovery applications. Chip-based nanoelectrospray coupled to a mass spectrometer detector is one of the recently developed analytical microscale technologies. This technology offers unique advantages for automated nanoelectrospray including reduced sample consumption, improved detection sensitivity and enhanced data quality for proteomic studies. This review presents an overview and introduction of recent developments in chip devices coupled to electrospray mass spectrometers including the development of the automated nanoelectrospray ionization chip device for protein characterization. Applications using automated chip-based nanoelectrospray ionization technology in proteomic and bioanalytical studies are also extensively reviewed in the fields of high-throughput protein identification, protein post-translational modification studies, top-down proteomics, biomarker screening by pattern recognition, noncovalent protein-ligand binding for drug discovery and lipid analysis. Additionally, future trends in chip-based nanoelectrospray technology are discussed.
Collapse
Affiliation(s)
- Sheng Zhang
- Cornell University, 135 Biotechnology Building, Ithaca, NY 14853, USA.
| | | |
Collapse
|
8
|
Mao S, Zhang J, Li H, Lin JM. Strategy for Signaling Molecule Detection by Using an Integrated Microfluidic Device Coupled with Mass Spectrometry to Study Cell-to-Cell Communication. Anal Chem 2012; 85:868-76. [DOI: 10.1021/ac303164b] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
- Sifeng Mao
- Beijing Key Laboratory of Microanalytical
Methods and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Jie Zhang
- Beijing Key Laboratory of Microanalytical
Methods and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Haifang Li
- Beijing Key Laboratory of Microanalytical
Methods and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Jin-Ming Lin
- Beijing Key Laboratory of Microanalytical
Methods and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| |
Collapse
|
9
|
Gao D, Li H, Wang N, Lin JM. Evaluation of the Absorption of Methotrexate on Cells and Its Cytotoxicity Assay by Using an Integrated Microfluidic Device Coupled to a Mass Spectrometer. Anal Chem 2012; 84:9230-7. [DOI: 10.1021/ac301966c] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Dan Gao
- Beijing Key Laboratory
of Microanalytical Method and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Haifang Li
- Beijing Key Laboratory
of Microanalytical Method and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Niejun Wang
- Beijing Key Laboratory
of Microanalytical Method and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Jin-Ming Lin
- Beijing Key Laboratory
of Microanalytical Method and
Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China
| |
Collapse
|
10
|
Mao S, Gao D, Liu W, Wei H, Lin JM. Imitation of drug metabolism in human liver and cytotoxicity assay using a microfluidic device coupled to mass spectrometric detection. LAB ON A CHIP 2012; 12:219-26. [PMID: 22094544 DOI: 10.1039/c1lc20678h] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
In this work, we developed a microfluidic device for the imitation of drug metabolism in human liver and its cytotoxicity on cells. The integrated microfluidic device consists of three sections: (1) bioreactors containing poly(ethylene) glycol (PEG) hydrogel encapsulated human liver microsomes (HLMs); (2) cell culture chambers for cytotoxicity assay; and (3) integrated micro solid-phase extraction (SPE) columns to desalt and concentrate the products of enzymatic reaction. To verify the feasibility of the integrated microchip, we studied uridine 5'-diphosphate-glucuronosyltransferase (UGT) metabolism of acetaminophen (AP) and the cytotoxicity of products on HepG2 cells. The products of the reaction in one region of the device were injected into the cell culture chamber for cytotoxicity assay, while those in another region were directly detected online with an electrospray ionization quadrupole time-of-flight mass spectrometer (ESI-Q-TOF MS) after micro-SPE pre-treatment. Semiquantitative analysis achieved in the experiments could be related to the drug-induced HepG2 cell cytotoxicity. Total analysis time for one product was about 30 min and only less than 4 μg HLM protein was required for one reaction region. The results demonstrated that the established platform could be used to imitate drug metabolism occurring in the human liver, thereby replacing animal experiments in the near future. In addition, the integrated microchip will be a useful tool for drug metabolism studies and cytotoxicity assays, which are pivotal in drug development.
Collapse
Affiliation(s)
- Sifeng Mao
- Beijing Key Laboratory of Microanalytical Method and Instrumentation, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | | | | | | | | |
Collapse
|
11
|
Uchiyama Y, Okubo F, Akai K, Fujii Y, Henares TG, Kawamura K, Yao T, Endo T, Hisamoto H. Combinable poly(dimethyl siloxane) capillary sensor array for single-step and multiple enzyme inhibitor assays. LAB ON A CHIP 2012; 12:204-208. [PMID: 22086459 DOI: 10.1039/c1lc20651f] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We describe a new method for fabricating a capillary-type sensor, called a combinable poly(dimethyl siloxane) (PDMS) capillary (CPC) sensor. The method for preparing the CPC simplifies enzyme inhibitor assays into a simple, single step assay. The sample inhibitor solution is introduced by capillary action. This triggers the spontaneous dissolution of physically adsorbed fluorescent substrates, and the substrate mixes with the inhibitor. This is followed by competitive reaction with insoluble enzyme to give a fluorescence response. CPC is composed of a convex-shaped PDMS stick containing reagents immobilized in an insoluble coating, and a concave-shaped PDMS stick containing reagents immobilized in a soluble coating. Since the concave-shaped PDMS has a deeper channel than the convex structure, combining these PDMS sticks is like closing the zipper of a "freezer bag". This allows easy fabrication of "thin and long" capillary structures containing different reagents inside the same capillary, without the need for precise alignment. This method allows the immobilization of two reactive reagents, such as enzyme and substrate required for a single step assay, which are typically very difficult to immobilize using commercially available conventional capillaries. Furthermore, by simply arraying various CPCs, the CPC sensor allows multiple assays. Here, we carried out a single-step enzyme inhibitor assay using the CPC. In addition, two independent CPCs were arrayed to demonstrate multiple assaying of a protease inhibitor.
Collapse
Affiliation(s)
- Yosuke Uchiyama
- Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai City, Osaka 599-8531, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Wei H, Li H, Mao S, Lin JM. Cell signaling analysis by mass spectrometry under coculture conditions on an integrated microfluidic device. Anal Chem 2011; 83:9306-13. [PMID: 22022860 DOI: 10.1021/ac201709f] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
A microfluidic device was integrated in a controlled coculture system, in which the secreted proteins were qualitatively and semiquantitatively determined by a directly coupled mass spectrometer. PC12 cells and GH3 cells were cocultured under various conditions as a model of the regulation of the organism by the nervous system. A micro-solid phase extraction (SPE) column was integrated in order to remove salts from the cells secretion prior to mass spectrometry detection. A three layer polydimethylsiloxane (PDMS) microfluidic device was fabricated to integrate valves for avoiding contamination between the cells coculture zone and the pretreatment zone. Electrospray ionization (ESI)-quadrupole (Q)-time of flight (TOF)-mass spectrometry was employed to realize highly sensitive qualitative analysis and to implement semiquantitative analysis. Furthermore, cell migrations under various coculture conditions were observed and discussed. The inhibition on growth hormone secretion from GH3 cells by dopamine released from PC12 cells was investigated and demonstrated. Thus, the developed platform provides a useful tool on cell to cell signaling studies for disease monitoring and drug delivery control.
Collapse
Affiliation(s)
- Huibin Wei
- Beijing Key Laboratory for Analytical Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing, China
| | | | | | | |
Collapse
|
13
|
Dahal UP, Jones JP, Davis JA, Rock DA. Small molecule quantification by liquid chromatography-mass spectrometry for metabolites of drugs and drug candidates. Drug Metab Dispos 2011; 39:2355-60. [PMID: 21937735 DOI: 10.1124/dmd.111.040865] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Identification and quantification of the metabolites of drugs and drug candidates are routinely performed using liquid chromatography-mass spectrometry (LC-MS). The best practice is to generate a standard curve with the metabolite versus the internal standard. However, to avoid the difficulties in metabolite synthesis, standard curves are sometimes prepared using the substrate, assuming that the signal for substrate and the metabolite will be equivalent. We have tested the errors associated with this assumption using a series of very similar compounds that undergo common metabolic reactions using both conventional flow electrospray ionization LC-MS and low-flow captive spray ionization (CSI) LC-MS. The differences in standard curves for four different types of transformations (O-demethylation, N-demethylation, aromatic hydroxylation, and benzylic hydroxylation) are presented. The results demonstrate that the signals of the substrates compared with those of the metabolites are statistically different in 18 of the 20 substrate-metabolite combinations for both methods. The ratio of the slopes of the standard curves varied up to 4-fold but was slightly less for the CSI method.
Collapse
Affiliation(s)
- Upendra P Dahal
- Department of Chemistry, Washington State University, Pullman, WA 99164-4630, USA
| | | | | | | |
Collapse
|
14
|
Forsberg EM, Green JRA, Brennan JD. Continuous Flow Immobilized Enzyme Reactor–Tandem Mass Spectrometry for Screening of AChE Inhibitors in Complex Mixtures. Anal Chem 2011; 83:5230-6. [PMID: 21591743 DOI: 10.1021/ac200534t] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Erica M. Forsberg
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4M1
| | - James R. A. Green
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4M1
| | - John D. Brennan
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4M1
| |
Collapse
|
15
|
Hervás M, López MA, Escarpa A. Integrated electrokinetic magnetic bead-based electrochemical immunoassay on microfluidic chips for reliable control of permitted levels of zearalenone in infant foods. Analyst 2011; 136:2131-8. [PMID: 21394379 DOI: 10.1039/c1an15081b] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Microfluidic technology has now become a novel sensing platform where different analytical steps, biological recognition materials and suitable transducers can be cleverly integrated yielding a new sensor generation. A novel "lab-on-a-chip" strategy integrating an electrokinetic magnetic bead-based electrochemical immunoassay on a microfluidic chip for reliable control of permitted levels of zearalenone in infant foods is proposed. The strategy implies the creative use of the simple channel layout of the double-T microchip to perform sequentially the immunointeraction and enzymatic reaction by applying a program of electric fields suitably connected to the reservoirs for driving the fluidics at different chambers in order to perform the different reactions. Both zones are used with the aid of a magnetic field to avoid in a very simple and elegant way the non-specific adsorption. Immunological reaction is performed under a competitive enzyme-linked immunosorbent assay (ELISA) where the mycotoxin ZEA and an enzyme-labelled derivative compete for the binding sites of the specific monoclonal antibody immobilised onto protein G modified magnetic beads. Horseradish peroxidase (HRP), in the presence of hydrogen peroxide, catalyses the oxidation of hydroquinone (HQ) to benzoquinone (BQN), whose back electrochemical reduction was detected at +0.1 V. Controlled-electrokinetic fluidic handling optimized conditions are addressed for all analytical steps cited above, and allows performing the complete immunoassay for the target ZEA analyte in less than 15 minutes with unique analytical merits: competitive immunoassay currents showed a very well-defined concentration dependence with a good precision as well as a suitable limit of detection of 0.4 µg L(-1), well below the legislative requirements, and an extremely low systematic error of 2% from the analysis of a maize certified reference material revealing additionally an excellent accuracy. Also, the reliability of the approach is demonstrated by the analysis of selected infant foods yielding the strictest ZEA permitted levels and excellent recoveries of 103 and 101% for solid and liquid samples, respectively.
Collapse
Affiliation(s)
- Mirian Hervás
- Department of Analytical Chemistry and Chemical Engineering, Faculty of Chemistry, Alcala University, Alcala de Henares, Madrid, Spain
| | | | | |
Collapse
|
16
|
van Midwoud PM, Verpoorte E, Groothuis GMM. Microfluidic devices for in vitro studies on liver drug metabolism and toxicity. Integr Biol (Camb) 2011; 3:509-21. [DOI: 10.1039/c0ib00119h] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
17
|
Greener J, Abbasi B, Kumacheva E. Attenuated total reflection Fourier transform infrared spectroscopy for on-chip monitoring of solute concentrations. LAB ON A CHIP 2010; 10:1561-1566. [PMID: 20376405 DOI: 10.1039/c001889a] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We report a cost-efficient Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR) method for monitoring concentrations of solutes in solutions flowing through microfluidic channels. The method allows rapid acquisition of spectra and enables chemical characterisation and concentration measurements that are independent of the flow rate of liquids. The method enables independent measurement of concentrations of solutes with distinct spectral features in mixed solutions. For the polymer solutes studied in the present work, the method has a sensitivity of at least 10 microM (0.01 wt%). We also propose the applicability of the method for the differentiation between dissolved and adsorbed amphiphilic species.
Collapse
Affiliation(s)
- Jesse Greener
- Department of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario, Canada M5S 3H6
| | | | | |
Collapse
|
18
|
Gao D, Wei H, Guo GS, Lin JM. Microfluidic Cell Culture and Metabolism Detection with Electrospray Ionization Quadrupole Time-of-Flight Mass Spectrometer. Anal Chem 2010; 82:5679-85. [DOI: 10.1021/ac101370p] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Dan Gao
- The Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China, and State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Huibin Wei
- The Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China, and State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Guang-Sheng Guo
- The Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China, and State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Jin-Ming Lin
- The Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China, and State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| |
Collapse
|
19
|
Wei H, Li H, Gao D, Lin JM. Multi-channel microfluidic devices combined with electrospray ionization quadrupole time-of-flight mass spectrometry applied to the monitoring of glutamate release from neuronal cells. Analyst 2010; 135:2043-50. [PMID: 20526497 DOI: 10.1039/c0an00162g] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This paper describes an integrated system combining microfluidic devices with electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-Q-TOF-MS) for monitoring cellular chemical release. To demonstrate the feasibility of this new system, the reported carnosine-protection process against Abeta42-induced glutamate released from PC12 cells, was monitored. Poly-L-lysine coated microchannels were used to culture cells. A multi-channel miniature extraction chip (MEC) was integrated into the design to remove salts and protein interference effects. ESI-Q-TOF-MS was employed to realize semi-quantitative and highly sensitive qualitative analysis. The protective effect of carnosine against Abeta42-induced neurotoxicity was evaluated under different conditions in microchannels in parallel. The secretion product analysis, carried out by ESI-Q-TOF-MS, was accomplished in 5 min using only 2.5 microL of solvent. Furthermore, we show that integrated microfluidic devices have significant potential for the analysis of cellular secretions, as well as for medical screening tests and for the diagnosis of specific diseases.
Collapse
Affiliation(s)
- Huibin Wei
- The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | | | | | | |
Collapse
|
20
|
Sikanen T, Franssila S, Kauppila TJ, Kostiainen R, Kotiaho T, Ketola RA. Microchip technology in mass spectrometry. MASS SPECTROMETRY REVIEWS 2010; 29:351-391. [PMID: 19514079 DOI: 10.1002/mas.20238] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Microfabrication of analytical devices is currently of growing interest and many microfabricated instruments have also entered the field of mass spectrometry (MS). Various (atmospheric pressure) ion sources as well as mass analyzers have been developed exploiting microfabrication techniques. The most common approach thus far has been the miniaturization of the electrospray ion source and its integration with various separation and sampling units. Other ionization techniques, mainly atmospheric pressure chemical ionization and photoionization, have also been subject to miniaturization, though they have not attracted as much attention. Likewise, all common types of mass analyzers have been realized by microfabrication and, in most cases, successfully applied to MS analysis in conjunction with on-chip ionization. This review summarizes the latest achievements in the field of microfabricated ion sources and mass analyzers. Representative applications are reviewed focusing on the development of fully microfabricated systems where ion sources or analyzers are integrated with microfluidic separation devices or microfabricated pums and detectors, respectively. Also the main microfabrication methods, with their possibilities and constraints, are briefly discussed together with the most commonly used materials.
Collapse
Affiliation(s)
- Tiina Sikanen
- Faculty of Pharmacy, Division of Pharmaceutical Chemistry, University of Helsinki, Helsinki, Finland.
| | | | | | | | | | | |
Collapse
|
21
|
Kraly JR, Holcomb RE, Guan Q, Henry CS. Review: Microfluidic applications in metabolomics and metabolic profiling. Anal Chim Acta 2009; 653:23-35. [PMID: 19800473 DOI: 10.1016/j.aca.2009.08.037] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2009] [Revised: 08/28/2009] [Accepted: 08/28/2009] [Indexed: 01/19/2023]
Abstract
Metabolomics is an emerging area of research focused on measuring small molecules in biological samples. There are a number of different types of metabolomics, ranging from global profiling of all metabolites in a single sample to measurement of a selected group of analytes. Microfluidics and related technologies have been used in this research area with good success. The aim of this review article is to summarize the use of microfluidics in metabolomics. Direct application of microfluidics to the determination of small molecules is covered first. Next, important sample preparation methods developed for microfluidics and applicable to metabolomics are covered. Finally, a summary of metabolomic work as it relates to analysis of cellular events using microfluidics is covered.
Collapse
Affiliation(s)
- James R Kraly
- Department of Chemistry, Colorado State University, Fort Collins, Colorado, CO 80523, United States
| | | | | | | |
Collapse
|
22
|
Ma B, Zhang G, Qin J, Lin B. Characterization of drug metabolites and cytotoxicity assay simultaneously using an integrated microfluidic device. LAB ON A CHIP 2009; 9:232-8. [PMID: 19107278 DOI: 10.1039/b809117j] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
An integrated microfluidic device was developed for the characterization of drug metabolites and a cytotoxicity assay simultaneously. The multi-layer device was composed of a quartz substrate with embedded separation microchannels and a perforated three-microwell array containing sol-gel bioreactors of human liver microsome (HLM), and two PDMS layers. By aligning the microwell array on the quartz substrate with cell culture chambers on the bottom PDMS layer, drug metabolism studies related to functional units, including metabolite generation, detection and incubation with cultured cells to assess metabolism induced cytotoxicity, were all integrated into the microfluidic device. To validate the feasibility of drug metabolism study on the microfluidic chip, UDP-glucuronosyltransferase (UGT) metabolism of acetaminophen (AP) and its effect on hepG2 cytotoxicity were studied first. Then metabolism based drug-drug interaction between AP and phenytoin (PH), which resulted in increased hepG2 cytotoxicity, was proved on this device. All this demonstrated that the developed microfluidic device could be a potential useful tool for drug metabolism and metabolism based drug-drug interaction research.
Collapse
Affiliation(s)
- Bo Ma
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, China
| | | | | | | |
Collapse
|
23
|
Rabe KS, Gandubert VJ, Spengler M, Erkelenz M, Niemeyer CM. Engineering and assaying of cytochrome P450 biocatalysts. Anal Bioanal Chem 2008; 392:1059-73. [PMID: 18622752 DOI: 10.1007/s00216-008-2248-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2008] [Revised: 06/11/2008] [Accepted: 06/12/2008] [Indexed: 11/29/2022]
Abstract
Cytochrome P450s constitute a highly fascinating superfamily of enzymes which catalyze a broad range of reactions. They are essential for drug metabolism and promise industrial applications in biotechnology and biosensing. The constant search for cytochrome P450 enzymes with enhanced catalytic performances has generated a large body of research. This review will concentrate on two key aspects related to the identification and improvement of cytochrome P450 biocatalysts, namely the engineering and assaying of these enzymes. To this end, recent advances in cytochrome P450 development are reported and commonly used screening methods are surveyed.
Collapse
Affiliation(s)
- Kersten S Rabe
- Fakultät für Chemie, Biologisch-Chemische Mikrostrukturtechnik, Technische Universität Dortmund, Otto-Hahn-Strabetae 6, 44227, Dortmund, Germany
| | | | | | | | | |
Collapse
|
24
|
Partserniak I, Werstuck G, Capretta A, Brennan JD. An ESI-MS/MS Method for Screening of Small-Molecule Mixtures against Glycogen Synthase Kinase-3β (GSK-3β). Chembiochem 2008; 9:1065-73. [DOI: 10.1002/cbic.200700674] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
25
|
Dong H, Li CM, Zhang YF, Cao XD, Gan Y. Screen-printed microfluidic device for electrochemical immunoassay. LAB ON A CHIP 2007; 7:1752-8. [PMID: 18030397 DOI: 10.1039/b712394a] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
In this paper, a new microfluidic array device has been fabricated with screen printing technology. In contrast to traditional microfabrication processes, our method is simple, inexpensive and also suitable for mass production. The device is used for sandwich-type electrochemical immunoassay, in which probes are covalently attached to the electrode surface via electropolymerized polypyrrole propylic acid (PPA) film. This novel microfluidic system enables the whole array preparation and detection processes, including the probe immobilization, sample injection, enzyme incubation and electrochemical detection, to be conducted in the sealed microchannels. For a demonstration, mouse IgG is selected as the target analyte and its detection is realized by sandwich ELISA with goat anti-mouse IgG, rat anti-mouse IgG (conjugated to alkaline phosphatase) and p-aminophenyl phosphate (PAPP) as the primary antibody, second antibody, and enzyme substrate, respectively. A detection limit of 10 ng mL(-1) (67 pM) is achieved with a dynamic range of 100 ng mL(-1)-10 microg mL(-1). In addition, anti-goat IgG is also immobilized as an alternative probe to test mouse IgG in the solution, in order to demonstrate the multiplexing capability as well as the specificity of the device. As expected, the electrochemical responses are much lower than that using anti-mouse IgG as the probe, indicating good selectivity of the immunoassay device. These results indicate a great promise toward the development of miniaturized, low-cost protein biochips for clinical, forensics, environmental, and pharmaceutical applications.
Collapse
Affiliation(s)
- Hua Dong
- Center for Advanced Bionanosystems, School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637457
| | | | | | | | | |
Collapse
|
26
|
Koster S, Verpoorte E. A decade of microfluidic analysis coupled with electrospray mass spectrometry: an overview. LAB ON A CHIP 2007; 7:1394-1412. [PMID: 17960264 DOI: 10.1039/b709706a] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This review presents a thorough overview covering the period 1997-2006 of microfluidic chips coupled to mass spectrometry through an electrospray interface. The different types of fabrication processes and materials used to fabricate these chips throughout this period are discussed. Three 'eras' of interfaces are clearly distinguished. The earliest approach involves spraying from the edge of a chip, while later devices either incorporate a standard fused-silica emitter inserted into the device or fully integrated emitters formed during chip fabrication. A summary of microfluidic-electrospray devices for performing separations and sample pretreatment steps before sample introduction into the mass spectrometer is also presented.
Collapse
Affiliation(s)
- Sander Koster
- Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands.
| | | |
Collapse
|
27
|
Roman GT, Kennedy RT. Fully integrated microfluidic separations systems for biochemical analysis. J Chromatogr A 2007; 1168:170-88; discussion 169. [PMID: 17659293 DOI: 10.1016/j.chroma.2007.06.010] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2007] [Accepted: 06/05/2007] [Indexed: 10/23/2022]
Abstract
Over the past decade a tremendous amount of research has been performed using microfluidic analytical devices to detect over 200 different chemical species. Most of this work has involved substantial integration of fluid manipulation components such as separation channels, valves, and filters. This level of integration has enabled complex sample processing on miniscule sample volumes. Such devices have also demonstrated high throughput, sensitivity, and separation performance. Although the miniaturization of fluidics has been highly valuable, these devices typically rely on conventional ancillary equipment such as power supplies, detection systems, and pumps for operation. This auxiliary equipment prevents the full realization of a "lab-on-a-chip" device with complete portability, autonomous operation, and low cost. Integration and/or miniaturization of ancillary components would dramatically increase the capability and impact of microfluidic separations systems. This review describes recent efforts to incorporate auxiliary equipment either as miniaturized plug-in modules or directly fabricated into the microfluidic device.
Collapse
Affiliation(s)
- Gregory T Roman
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055, USA
| | | |
Collapse
|
28
|
Staack RF, Hopfgartner G. New analytical strategies in studying drug metabolism. Anal Bioanal Chem 2007; 388:1365-80. [PMID: 17583803 DOI: 10.1007/s00216-007-1367-z] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2007] [Revised: 05/09/2007] [Accepted: 05/11/2007] [Indexed: 01/03/2023]
Abstract
Identification and elucidation of the structures of metabolites play major roles in drug discovery and in the development of pharmaceutical compounds. These studies are also important in toxicology or doping control with either pharmaceuticals or illicit drugs. This review focuses on: new analytical strategies used to identify potential metabolites in biological matrices with and without radiolabeled drugs; use of software for metabolite profiling; interpretation of product spectra; profiling of reactive metabolites; development of new approaches for generation of metabolites; and detection of metabolites with increased sensitivity and simplicity. Most of the new strategies involve mass spectrometry (MS) combined with liquid chromatography (LC).
Collapse
Affiliation(s)
- Roland F Staack
- Life Sciences Mass Spectrometry, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, 20, Bd d'Yvoy, 1211 Genève 4, Switzerland
| | | |
Collapse
|
29
|
Hodgson RJ, Besanger TR, Brook MA, Brennan JD. Inhibitor screening using immobilized enzyme reactor chromatography/mass spectrometry. Anal Chem 2007; 77:7512-9. [PMID: 16316156 DOI: 10.1021/ac050761q] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We describe the coupling of capillary-scale monolithic enzyme reactor columns directly to a tandem mass spectrometer for screening of enzyme inhibitors. A two-channel nanoLC system is used to continuously infuse substrate or substrate/inhibitor mixtures through the column, allowing continuous variation of inhibitor concentration by simply altering the ratio of flow from the two pumps. In the absence of inhibitor, infusion of substrate leads to formation of product, and both substrate and product ions can be simultaneously monitored in a quantitative manner by MS/MS. The presence of inhibitor leads to a decrease in product and an increase in substrate concentration in the column eluent. Knowing the product/substrate ratio and the total analyte concentration (P + S), the concentration of product eluting, and hence the relative enzyme activity, can be determined. Both IC50 and KI values can then be obtained by direct MS detection of the effect of inhibitors on relative activity. Inhibitor screening is demonstrated using reusable, sol-gel derived, monolithic capillary columns containing adenosine deaminase, directly interfaced to ESI-MS/MS. On-column enzyme activity was assessed by monitoring inosine and adenosine elution. It is shown that the method can be used for automated screening of the effects of compound mixtures on ADA activity and to determine the KI value of the known inhibitor, erythro-9-(2-hydroxy-3-nonyl)adenine, even when the compound is present within a mixture.
Collapse
Affiliation(s)
- Richard J Hodgson
- Department of Chemistry, McMaster University, Hamilton, Ontario, Canada
| | | | | | | |
Collapse
|
30
|
Abstract
Recent advances of microfluidics systems suitable for multiplexed MS analysis are reviewed with respect to fabrication technologies and applications.
Collapse
|
31
|
|
32
|
Goral VN, Zaytseva NV, Baeumner AJ. Electrochemical microfluidic biosensor for the detection of nucleic acid sequences. LAB ON A CHIP 2006; 6:414-21. [PMID: 16511625 DOI: 10.1039/b513239h] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
A microfluidic biosensor with electrochemical detection for the quantification of nucleic acid sequences was developed. In contrast to most microbiosensors that are based on fluorescence for signal generation, it takes advantage of the simplicity and high sensitivity provided by an amperometric and coulorimetric detection system. An interdigitated ultramicroelectrode array (IDUA) was fabricated in a glass chip and integrated directly with microchannels made of poly(dimethylsiloxane) (PDMS). The assembly was packaged into a Plexiglas housing providing fluid and electrical connections. IDUAs were characterized amperometrically and using cyclic voltammetry with respect to static and dynamic responses for the presence of a reversible redox couple-potassium hexacyanoferrate (ii)/hexacyanoferrate (iii) (ferri/ferrocyanide). A combined concentration of 0.5 microM of ferro/ferricyanide was determined as lower limit of detection with a dynamic range of 5 orders of magnitude. Background signals were negligible and the IDUA responded in a highly reversible manner to the injection of various volumes and various concentrations of the electrochemical marker. For the detection of nucleic acid sequences, liposomes entrapping the electrochemical marker were tagged with a DNA probe, and superparamagnetic beads were coated with a second DNA probe. A single stranded DNA target sequence hybridized with both probes. The sandwich was captured in the microfluidic channel just upstream of the IDUA via a magnet located in the outside housing. Liposomes were lysed using a detergent and the amount of released ferro/ferricyanide was quantified while passing by the IDUA. Optimal location of the magnet with respect to the IDUA was investigated, the effect of dextran sulfate on the hybridization reaction was studied and the amount of magnetic beads used in the assay was optimized. A dose response curve using varying concentrations of target DNA molecules was carried out demonstrating a limit of detection at 1 fmol assay(-1) and a dynamic range between 1 and 50 fmol. The overall assay took 6 min to complete, plus 15-20 min of pre-incubation and required only a simple potentiostat for signal recording and interpretation.
Collapse
Affiliation(s)
- Vasiliy N Goral
- Department of Biological and Environmental Engineering, Cornell University, Ithaca, NY 14853, USA
| | | | | |
Collapse
|
33
|
Bedair MF, Oleschuk RD. Fabrication of Porous Polymer Monoliths in Polymeric Microfluidic Chips as an Electrospray Emitter for Direct Coupling to Mass Spectrometry. Anal Chem 2006; 78:1130-8. [PMID: 16478104 DOI: 10.1021/ac0514570] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Coupling of polymeric microfluidic devices to mass spectrometry is reported using porous polymer monoliths (PPM) as nanoelectrospray emitters. Lauryl acrylate-co-ethylene dimethacrylate porous polymer monolith was photopatterned for 5 mm at the end of the channel of microfluidic devices fabricated from three different polymeric substrate materials, including the following: poly(dimethylsiloxane) (PDMS), poly(methyl methacrylate) (PMMA), and cyclic olefin copolymer (COC). Spraying directly from the end of the chip removes any dead volume associated with inserted emitters or transfer lines, and the presence of multiple pathways in the PPM prevents the clogging of the channels, which is a common problem in conventional nanospray emitters. Spraying from a microfluidic channel having a PPM emitter produced a substantial increase in TIC stability and increased sensitivity by as much as 70x compared to spraying from an open end chip with no PPM. The performance of PPM emitter in COC, PMMA, and PDMS chips was compared in terms of stability and reproducibility of the electrospray. COC chips showed the highest reproducibility in terms of chip-to-chip performance, which can be attributed to the ease and reproducibility of the PPM formation due to the favorable optical and chemical properties of COC. We have further tested the performance of the COC chips by constant infusion of poly(propylene glycol) solution at organic content ranging from 10 to 90% methanol and at flow rates ranging from 50 to 1000 nL/min, showing optimum spraying conditions (RSD < 5%) at 50-70% organic content and at flow rates from 100 to 500 nL/min. The PPM sprayer was also used for protein preconcentration and desalting prior to mass spectrometric detection, and results were comparable with a chip spraying from an electrospray tip.
Collapse
Affiliation(s)
- Mohamed F Bedair
- Department of Chemistry, Queen's University, Kingston, Ontario, Canada K7L 3N6
| | | |
Collapse
|
34
|
Du Y, Wei H, Kang J, Yan J, Yin XB, Yang X, Wang E. Microchip Capillary Electrophoresis with Solid-State Electrochemiluminescence Detector. Anal Chem 2005; 77:7993-7. [PMID: 16351147 DOI: 10.1021/ac051369f] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We report microchip capillary electrophoresis (CE) coupling to a solid-state electrochemiluminescence (ECL) detector. The solid-state ECL detector was fabricated by immobilizing tris(2,2'-bipyridyl)ruthenium(II) (TBR) into an Eastman AQ55D-silica-carbon nanotube composite thin film on an indium tin oxide (ITO) electrode. After being made by a photolithographic method, the surface of the ITO electrode was coated with a thin composite film through a micromolding in capillary (MIMIC) technique using a poly(dimethylsiloxane) (PDMS) microchannel with the same pattern as an ITO electrode. Then the TBR was immobilized via ion exchange by immersing the ITO electrode containing the thin film in TBR aqueous solution. The whole system was built by reversibly sealing the TBR-modified ITO electrode plate with a PDMS layer containing electrophoresis microchannels. The results indicated that the present solid-state ECL detector displayed good durability and stability in the microchip CE-ECL system. Proline was selected to perform the microchip device with a limit of detection of 2 microM (S/N=3) and a linear range from 25 to 1000 microM. Compared with the CE-ECL of TBR in aqueous solution, while the CE microchip with solid-state ECL detector system gave the same sensitivity of analysis, a much lower TBR consumption and a high integration of the whole system were obtained. The present system was also used for medicine analysis.
Collapse
Affiliation(s)
- Yan Du
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Graduate School of the Chinese Academy of Sciences, Changchun, Jilin, 130022, P. R. China
| | | | | | | | | | | | | |
Collapse
|
35
|
de Boer AR, Bruyneel B, Krabbe JG, Lingeman H, Niessen WMA, Irth H. A microfluidic-based enzymatic assay for bioactivity screening combined with capillary liquid chromatography and mass spectrometry. LAB ON A CHIP 2005; 5:1286-92. [PMID: 16234953 DOI: 10.1039/b506559c] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The design and implementation of a continuous-flow microfluidic assay for the screening of (complex) mixtures for bioactive compounds is described. The microfluidic chip featured two microreactors (1.6 and 2.4 microL) in which an enzyme inhibition and a substrate conversion reaction were performed, respectively. Enzyme inhibition was detected by continuously monitoring the products formed in the enzyme-substrate reaction by electrospray ionization mass spectrometry (ESI-MS). In order to enable the screening of mixtures of compounds, the chip-based assay was coupled on-line to capillary reversed-phase high-performance liquid chromatography (HPLC) with the HPLC column being operated either in isocratic or gradient elution mode. In order to improve the detection limits of the current method, sample preconcentration based on a micro on-line solid-phase extraction column was employed. The use of electrospray MS allowed the simultaneous detection of chemical (MS spectra) and biological parameters (enzyme inhibition) of ligands eluting from the HPLC column. The present system was optimized and validated using the protease cathepsin B as enzyme of choice. Inhibition of cathepsin B is detected by monitoring three product traces, obtained by cleavage of the substrate. The two microreactors provided 32 and 36 s reaction time, respectively, which resulted in sufficient assay dynamics to enable the screening of bioactive compounds. The total flow rate was 4 microL min-1, which a 25-fold decrease was compared with a macro-scale system described earlier. Detection limits of 0.17-2.6 micromol L-1 were obtained for the screening of inhibitors, which is comparable to either microtiter plate assays or continuous-flow assays described in the literature.
Collapse
Affiliation(s)
- Arjen R de Boer
- Vrije Universiteit Amsterdam, Faculty of Sciences, Department of Chemistry and Pharmaceutical Sciences, Section Analytical Chemistry & Applied Spectroscopy, De Boelelaan 1083, 1081 HV Amsterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
36
|
Brivio M, Oosterbroek RE, Verboom W, van den Berg A, Reinhoudt DN. Simple chip-based interfaces for on-line monitoring of supramolecular interactions by nano-ESI MS. LAB ON A CHIP 2005; 5:1111-22. [PMID: 16175268 DOI: 10.1039/b510534j] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Two simple interfaces were designed and realized, enabling on-line coupling of microfluidics reactor chips to a nanoflow electrospray ionization (NESI) time-of-flight (TOF) mass spectrometer (MS). The interfaces are based on two different approaches: a monolithically integrated design, in which ionization is assisted by on-chip gas nebulization, and a modular approach implying the use of commercially available Picospray tips. Using reserpine as a reference compound in a 1ratio1 mixture of acetonitrile and water revealed that both interfaces provide a remarkably stable mass spectrometric signal (standard deviations lower than 8% and 1% for the monolithic and modular approaches, respectively). Glass microreactors, containing mixing zones, were fabricated and coupled to the modular interface with perfluoroelastomer Nanoport fluidics connectors, providing a tool to study chemical reactions on-line. Investigation of the mixing dynamics showed that complete on-chip reagents mixing is achieved within a few tens of milliseconds. Metal-ligand interactions of Zn-porphyrin with pyridine (2), 4-ethylpyridine (3), 4-phenylpyridine (4), N-methylimidazole (5), and N-butylimidazole (6) in acetonitrile as well as host-guest complexations of beta-cyclodextrin (7) with N-(1-adamantyl)acetamide (8) or 4-tert-butylacetanilide (9) in water were studied by mass spectrometry using the modular NESI-chip interface. From on-chip dilution-based mass spectrometric titrations of Zn-porphyrin 1 with pyridine (2) or 4-phenylpyridine (4) in acetonitrile Ka-values of 4.6 +/- 0.4 x 10(3) M(-1) and 6.5 +/- 1.2 x 10(3) M(-1), respectively, were calculated. The Ka-values are about four times larger than those obtained with UV/vis spectroscopy in solution, probably due to a higher ionization efficiency of complexed compared to uncomplexed Zn-porphyrin. For the complexation of N-(1-adamantyl)acetamide (8) with beta-cyclodextrin (7), a Ka-value of 3.6 +/- 0.3 x 10(4) M(-1) was obtained, which is in good agreement with that determined by microcalorimetry.
Collapse
Affiliation(s)
- Monica Brivio
- Laboratory of Supramolecular Chemistry and Technology, MESA+ Institute for Nanotechnology, University of Twente, P. O. Box 217, 7500 AE, Enschede, The Netherlands
| | | | | | | | | |
Collapse
|
37
|
Yang Y, Li C, Kameoka J, Lee KH, Craighead HG. A polymeric microchip with integrated tips and in situ polymerized monolith for electrospray mass spectrometry. LAB ON A CHIP 2005; 5:869-76. [PMID: 16027939 DOI: 10.1039/b503025k] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We describe the integration of a cyclo-olefin polymer based microchip with a sheathless capillary tip for electrospray ionization-mass spectrometry (ESI-MS). The microchip was fabricated by hot embossing and thermal bonding. Its design includes a side channel for adjusting the composition of the electrospray solution so that analytes in 100% water can be analyzed. The fused silica capillaries, used for sample introduction, and the electrospray tips for MS coupling were directly inserted into the microchannel before thermal bonding of the device. A microfabricated on-chip gold microelectrode was used to apply the electrospray voltage. Annealing the device after thermal bonding increased the pressure resistance of the microchip. The cross section of the microchannel was imaged by scanning electron microscopy to estimate the effects of the annealing step. The relationship between the applied electrospray voltages and MS signal was measured at different flow rates by coupling the device to an ion trap mass spectrometer. The performance of the microchip was evaluated by MS analysis of imipramine in ammonium acetate buffer solution by direct infusion. An alkylacrylate based monolith polymer bed for on-chip sample pretreatment and separation was polymerized in the microchannel and tested for ESI-MS applications.
Collapse
Affiliation(s)
- Yanou Yang
- Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA
| | | | | | | | | |
Collapse
|
38
|
Zguris JC, Itle LJ, Hayes D, Pishko MV. Microreactor Microfluidic Systems with Human Microsomes and Hepatocytes for use in Metabolite Studies. Biomed Microdevices 2005; 7:117-25. [PMID: 15940424 DOI: 10.1007/s10544-005-1589-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
In the area of drug discovery, high-speed synthesis has increased the number of drug candidates produced. These potential drugs need to be evaluated for their adsorption, distribution, metabolism, elimination, and toxicology (ADMET) properties as early in the drug development stage as possible. Previously, a potential drug's ADMET properties have been found out by using monolayer cell cultures and live animals. These methods can be costly, time-intensive, and impractical for screening the large amount of potential drugs created by combinatorial chemistry. A quick, small, inexpensive, and highly parallel device would be desirable to determine a drug candidate's properties (i.e., metabolism of the drug). Here we fabricate a microfluidic device entrapping human microsomes within poly(ethylene) glycol hydrogels thereby generating an in situ microreactor to assess a drug candidate's metabolic properties that can be coupled to analysis equipment. We show that microsomes can be entrapped without the loss of enzymatic activity during photopolymerization. Additionally, a microreactor utilizing hepatocytes was also created for comparison with the microsome microreactor.
Collapse
Affiliation(s)
- Jeanna C Zguris
- Department of Chemical Engineering, The Pennsylvania State University, University Park, PA 16802-4420, USA
| | | | | | | |
Collapse
|
39
|
van Liempd SM, Kool J, Reinen J, Schenk T, Meerman JHNA, Irth H, Vermeulen NPE. Development and validation of a microsomal online cytochrome P450 bioreactor coupled to solid-phase extraction and reversed-phase liquid chromatography. J Chromatogr A 2005; 1075:205-12. [PMID: 15974134 DOI: 10.1016/j.chroma.2005.03.084] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The development and validation of an online cytochrome P450 (CYP)-based bioreactor coupled to automated solid-phase extraction (SPE) and gradient HPLC separation is described. The analytical method was checked on intra- and inter-day repeatability of the ethoxyresorufin-O-demethylation (EROD) reaction with CYP 1Al/1A2 containing beta-NF induced rat liver microsomes as an enzyme source. These experiments showed that CYP activity was linearly decreased with 16% over an 11 h period. Inter-day measurements had a CV of 9.1%. Furthermore, Km and Vmax values of the EROD reaction, measured with the bioreactor, were 2.72 +/- 0.46 microM and 7.9 +/- 0.5 nmol/min/mg protein, respectively. These were in good correspondence with Km and Vmax values, measured with standard batch assay, which amounted 0.66 +/- 0.08 microM and 6.4 +/- 0.2 nmol/min/mg protein respectively. In conclusion the newly developed analytical method can be used effectively and at a microliter scale for online generation, extraction and separation of metabolites.
Collapse
Affiliation(s)
- Sebastiaan M van Liempd
- LACDR-Division of Molecular Toxicology, Department of Pharmacochemistry, Vrije Universiteit, De Boelelaan 1083, 1081 HVAmsterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
40
|
Abstract
The cytochrome P450 (P450) field came out of interest in the metabolism of drugs, carcinogens, and steroids, which remain major focal points. Over the years we have come to understand the P450 system components, the multiplicity of P450s, and many aspects of the regulation of the genes and also the catalytic mechanism. Many crystal structures are now becoming available. The significance of P450 in in vivo metabolism is appreciated, particularly in the context of pharmacogenetics. Current scientific issues involve posttranslational modification, gene regulation, component interactions, structures of P450 complexed with ligands, details of high-valent oxygen chemistry, the nature and influence of rate-limiting steps, greater details about some reaction steps, cooperativity, and the relevance of P450 variations to cancer risk. Some emerging research areas involve new methods of analysis of ligand interactions, roles of conformational changes linked to individual reaction steps, functions of orphan P450s, "molecular breeding" of new P450 functions and enhanced activity, and the utilization of P450s in chemical synthesis.
Collapse
Affiliation(s)
- F Peter Guengerich
- Department of Biochemistry, Center in Molecular Toxicology, Vanderbilt University School of Medicine, Nashville, Tennessee 37232-0146, USA.
| |
Collapse
|
41
|
Vandaveer WR, Pasas-Farmer SA, Fischer DJ, Frankenfeld CN, Lunte SM. Recent developments in electrochemical detection for microchip capillary electrophoresis. Electrophoresis 2004; 25:3528-49. [PMID: 15565707 DOI: 10.1002/elps.200406115] [Citation(s) in RCA: 229] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Significant progress in the development of miniaturized microfluidic systems has occurred since their inception over a decade ago. This is primarily due to the numerous advantages of microchip analysis, including the ability to analyze minute samples, speed of analysis, reduced cost and waste, and portability. This review focuses on recent developments in integrating electrochemical (EC) detection with microchip capillary electrophoresis (CE). These detection modes include amperometry, conductimetry, and potentiometry. EC detection is ideal for use with microchip CE systems because it can be easily miniaturized with no diminution in analytical performance. Advances in microchip format, electrode material and design, decoupling of the detector from the separation field, and integration of sample preparation, separation, and detection on-chip are discussed. Microchip CEEC applications for enzyme/immunoassays, clinical and environmental assays, as well as the detection of neurotransmitters are also described.
Collapse
Affiliation(s)
- Walter R Vandaveer
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS 66047, USA
| | | | | | | | | |
Collapse
|
42
|
Affiliation(s)
- Torsten Vilkner
- Department of Chemistry, Imperial College London, Exhibition Road, SW7 2AZ London, UK
| | | | | |
Collapse
|
43
|
Unger M, Frank A. Simultaneous determination of the inhibitory potency of herbal extracts on the activity of six major cytochrome P450 enzymes using liquid chromatography/mass spectrometry and automated online extraction. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2004; 18:2273-2281. [PMID: 15384148 DOI: 10.1002/rcm.1621] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Here we describe a liquid chromatography/mass spectrometry (LC/MS) method with automated online extraction (LC/LC/MS) to simultaneously determine the in vitro inhibitory potency of herbal extracts on six major human drug-metabolising cytochrome P450 enzymes. Substrates were incubated with a commercially available mixture of CYP1A2/2C8/2C9/2C19/2D6 and 3A4 from baculovirus-infected insect cells and the resulting metabolites were quantified with LC/LC/MS using electrospray ionisation in the selected ion monitoring mode. Consistent inhibitory activities were obtained for known inhibitors and plant extracts using the enzyme/substrate cocktail and the individual enzymes/substrates. Popular herbal remedies including devil's claw root (Harpagophytum procumbens), feverfew herb (Tanacetum parthenium), fo-ti root (Polygonum multiflorum), kava-kava root (Piper methysticum), peppermint oil (Mentha piperita), eucalyptus oil (Eucalyptus globulus), red clover blossom (Trifolium pratense) and grapefruit juice (GJ; Citrus paradisi) could be identified as inhibitors of the applied CYP enzymes with IC(50) values between 20 and 1000 microg/mL.
Collapse
Affiliation(s)
- Matthias Unger
- Institute of Pharmacy and Food Chemistry, Julius Maximilians-University Würzburg, 97074 Würzburg, Germany.
| | | |
Collapse
|
44
|
Froesch M, Bindila LM, Baykut G, Allen M, Peter-Katalinić J, Zamfir AD. Coupling of fully automated chip electrospray to Fourier transform ion cyclotron resonance mass spectrometry for high-performance glycoscreening and sequencing. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2004; 18:3084-3092. [PMID: 15562445 DOI: 10.1002/rcm.1733] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The NanoMate robot has been coupled to a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer at 9.4 T and implemented for the first time for complex carbohydrate analysis. It was optimized in the negative ion mode to achieve automated sample delivery on the chip along with increased sensitivity, ultra-high resolution and accurate mass determination. A novel bracket has been designed to allow a reliable mounting of the NanoMate to the Apollo electrospray ionization (ESI) source of an APEX II instrument. The notably higher efficiency of ionization for compositional mapping of complex mixtures and feasibility for fragmentation analysis of components by sustained off-resonance irradiation collision-induced tandem mass spectrometry (SORI-CID MS2) has been demonstrated on a glycoconjugate mixture containing O-glycosylated sialylated peptides from urine of a patient suffering from a hereditary N-acetylhexosaminidase deficiency (Schindler's disease), previously analyzed by capillary-based nanoESI-FTICRMS, and of a healthy control person. Due to its potential to generate highly charged ionic species, reduce the in-source fragmentation, increase sensitivity, reproducibility and ionization efficiency, along with the ability to generate a sustained and constant electrospray, this method can be considered as a new platform for advanced glycomics.
Collapse
Affiliation(s)
- Martin Froesch
- Institute for Medical Physics and Biophysics, University of Münster, Robert Koch Str. 31, 48149 Münster, Germany
| | | | | | | | | | | |
Collapse
|