1
|
Yun BH, Guo J, Bellamri M, Turesky RJ. DNA adducts: Formation, biological effects, and new biospecimens for mass spectrometric measurements in humans. MASS SPECTROMETRY REVIEWS 2020; 39:55-82. [PMID: 29889312 PMCID: PMC6289887 DOI: 10.1002/mas.21570] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 04/25/2018] [Indexed: 05/18/2023]
Abstract
Hazardous chemicals in the environment and diet or their electrophilic metabolites can form adducts with genomic DNA, which can lead to mutations and the initiation of cancer. In addition, reactive intermediates can be generated in the body through oxidative stress and damage the genome. The identification and measurement of DNA adducts are required for understanding exposure and the causal role of a genotoxic chemical in cancer risk. Over the past three decades, 32 P-postlabeling, immunoassays, gas chromatography/mass spectrometry, and liquid chromatography/mass spectrometry (LC/MS) methods have been established to assess exposures to chemicals through measurements of DNA adducts. It is now possible to measure some DNA adducts in human biopsy samples, by LC/MS, with as little as several milligrams of tissue. In this review article, we highlight the formation and biological effects of DNA adducts, and highlight our advances in human biomonitoring by mass spectrometric analysis of formalin-fixed paraffin-embedded tissues, untapped biospecimens for carcinogen DNA adduct biomarker research.
Collapse
Affiliation(s)
- Byeong Hwa Yun
- Masonic Cancer Center and Department of Medicinal Chemistry, University of Minnesota, 2231 6 St. SE, Minneapolis, Minnesota, 55455, United States
| | - Jingshu Guo
- Masonic Cancer Center and Department of Medicinal Chemistry, University of Minnesota, 2231 6 St. SE, Minneapolis, Minnesota, 55455, United States
| | - Medjda Bellamri
- Masonic Cancer Center and Department of Medicinal Chemistry, University of Minnesota, 2231 6 St. SE, Minneapolis, Minnesota, 55455, United States
| | - Robert J. Turesky
- Masonic Cancer Center and Department of Medicinal Chemistry, University of Minnesota, 2231 6 St. SE, Minneapolis, Minnesota, 55455, United States
| |
Collapse
|
2
|
Wang P, Ji R, Ji J, Chen F. Changes of metabolites of acrylamide and glycidamide in acrylamide-exposed rats pretreated with blueberry anthocyanins extract. Food Chem 2019; 274:611-619. [DOI: 10.1016/j.foodchem.2018.08.058] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 07/17/2018] [Accepted: 08/13/2018] [Indexed: 12/13/2022]
|
3
|
Evtugyn GA, Porfireva AV, Stoikov II. Electrochemical DNA sensors based on spatially distributed redox mediators: challenges and promises. PURE APPL CHEM 2017. [DOI: 10.1515/pac-2016-1124] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
AbstractDNA and aptasensors are widely used for fast and reliable detection of disease biomarkers, pharmaceuticals, toxins, metabolites and other species necessary for biomedical diagnostics. In the overview, the concept of spatially distributed redox mediators is considered with particular emphasis to the signal generation and biospecific layer assembling. The application of non-conductive polymers bearing redox labels, supramolecular carriers with attached DNA aptamers and redox active dyes and E-sensor concept are considered as examples of the approach announced.
Collapse
Affiliation(s)
- Gennady A. Evtugyn
- A.M.Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russian Federation
| | - Anna V. Porfireva
- A.M.Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russian Federation
| | - Ivan I. Stoikov
- A.M.Butlerov’ Chemistry Institute of Kazan Federal University, 420008 Kazan, Russian Federation
| |
Collapse
|
4
|
Song B, Shen M, Jiang D, Malla S, Mosa IM, Choudhary D, Rusling JF. Microfluidic array for simultaneous detection of DNA oxidation and DNA-adduct damage. Analyst 2016; 141:5722-5729. [PMID: 27517117 PMCID: PMC5048564 DOI: 10.1039/c6an01237j] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Exposure to chemical pollutants and pharmaceuticals may cause health issues caused by metabolite-related toxicity. This paper reports a new microfluidic electrochemical sensor array with the ability to simultaneously detect common types of DNA damage including oxidation and nucleobase adduct formation. Sensors in the 8-electrode screen-printed carbon array were coated with thin films of metallopolymers osmium or ruthenium bipyridyl-poly(vinylpyridine) chloride (OsPVP, RuPVP) along with DNA and metabolic enzymes by layer-by-layer electrostatic assembly. After a reaction step in which test chemicals and other necessary reagents flow over the array, OsPVP selectively detects oxidized guanines on the DNA strands, and RuPVP detects DNA adduction by metabolites on nucleobases. We demonstrate array performance for test chemicals including 17β-estradiol (E2), its metabolites 4-hydroxyestradiol (4-OHE2), 2-hydroxyestradiol (2-OHE2), catechol, 2-nitrosotoluene (2-NO-T), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), and 2-acetylaminofluorene (2-AAF). Results revealed DNA-adduct and oxidation damage in a single run to provide a metabolic-genotoxic chemistry screen. The array measures damage directly in unhydrolyzed DNA, and is less expensive, faster, and simpler than conventional methods to detect DNA damage. The detection limit for oxidation is 672 8-oxodG per 106 bases. Each sensor requires only 22 ng of DNA, so the mass detection limit is 15 pg (∼10 pmol) 8-oxodG.
Collapse
Affiliation(s)
- Boya Song
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.
| | | | | | | | | | | | | |
Collapse
|
5
|
Liu S, Wang Y. Mass spectrometry for the assessment of the occurrence and biological consequences of DNA adducts. Chem Soc Rev 2015; 44:7829-54. [PMID: 26204249 PMCID: PMC4787602 DOI: 10.1039/c5cs00316d] [Citation(s) in RCA: 102] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Exogenous and endogenous sources of chemical species can react, directly or after metabolic activation, with DNA to yield DNA adducts. If not repaired, DNA adducts may compromise cellular functions by blocking DNA replication and/or inducing mutations. Unambiguous identification of the structures and accurate measurements of the levels of DNA adducts in cellular and tissue DNA constitute the first and important step towards understanding the biological consequences of these adducts. The advances in mass spectrometry (MS) instrumentation in the past 2-3 decades have rendered MS an important tool for structure elucidation, quantification, and revelation of the biological consequences of DNA adducts. In this review, we summarized the development of MS techniques on these fronts for DNA adduct analysis. We placed our emphasis of discussion on sample preparation, the combination of MS with gas chromatography- or liquid chromatography (LC)-based separation techniques for the quantitative measurement of DNA adducts, and the use of LC-MS along with molecular biology tools for understanding the human health consequences of DNA adducts. The applications of mass spectrometry-based DNA adduct analysis for predicting the therapeutic outcome of anti-cancer agents, for monitoring the human exposure to endogenous and environmental genotoxic agents, and for DNA repair studies were also discussed.
Collapse
Affiliation(s)
- Shuo Liu
- Environmental Toxicology Graduate Program, University of California, Riverside, California, USA
| | - Yinsheng Wang
- Environmental Toxicology Graduate Program, University of California, Riverside, California, USA and Department of Chemistry, University of California, Riverside, CA 92521-0403, USA.
| |
Collapse
|
6
|
Wasalathanthri DP, Li D, Song D, Zheng Z, Choudhary D, Jansson I, Lu X, Schenkman JB, Rusling JF. Elucidating Organ-Specific Metabolic Toxicity Chemistry from Electrochemiluminescent Enzyme/DNA Arrays and Bioreactor Bead-LC-MS/MS. Chem Sci 2015; 6:2457-2468. [PMID: 25798217 PMCID: PMC4364445 DOI: 10.1039/c4sc03401e] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 02/12/2015] [Indexed: 12/15/2022] Open
Abstract
Human toxic responses are very often related to metabolism. Liver metabolism is traditionally studied, but other organs also convert chemicals and drugs to reactive metabolites leading to toxicity. When DNA damage is found, the effects are termed genotoxic. Here we describe a comprehensive new approach to evaluate chemical genotoxicity pathways from metabolites formed in-situ by a broad spectrum of liver, lung, kidney and intestinal enzymes. DNA damage rates are measured with a microfluidic array featuring a 64-nanowell chip to facilitate fabrication of films of DNA, electrochemiluminescent (ECL) detection polymer [Ru(bpy)2(PVP)10]2+ {(PVP = poly(4-vinylpyridine)} and metabolic enzymes. First, multiple enzyme reactions are run on test compounds using the array, then ECL light related to the resulting DNA damage is measured. A companion method next facilitates reaction of target compounds with DNA/enzyme-coated magnetic beads in 96 well plates, after which DNA is hydrolyzed and nucleobase-metabolite adducts are detected by LC-MS/MS. The same organ enzymes are used as in the arrays. Outcomes revealed nucleobase adducts from DNA damage, enzymes responsible for reactive metabolites (e.g. cyt P450s), influence of bioconjugation, relative dynamics of enzymes suites from different organs, and pathways of possible genotoxic chemistry. Correlations between DNA damage rates from the cell-free array and organ-specific cell-based DNA damage were found. Results illustrate the power of the combined DNA/enzyme microarray/LC-MS/MS approach to efficiently explore a broad spectrum of organ-specific metabolic genotoxic pathways for drugs and environmental chemicals.
Collapse
Affiliation(s)
| | - Dandan Li
- Department of Chemistry , University of Connecticut , Storrs , Connecticut 06269 , USA .
| | - Donghui Song
- Department of Pharmaceutical Sciences , University of Connecticut , Storrs , Connecticut 06269 , USA
| | - Zhifang Zheng
- Department of Chemistry , University of Connecticut , Storrs , Connecticut 06269 , USA .
| | - Dharamainder Choudhary
- Department of Surgery , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| | - Ingela Jansson
- Department of Cell Biology , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| | - Xiuling Lu
- Department of Pharmaceutical Sciences , University of Connecticut , Storrs , Connecticut 06269 , USA
| | - John B. Schenkman
- Department of Cell Biology , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| | - James F. Rusling
- Department of Chemistry , University of Connecticut , Storrs , Connecticut 06269 , USA .
- National University of Ireland at Galway , Ireland
- Department of Cell Biology , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| |
Collapse
|
7
|
Strongly enhanced guanine electrooxidation caused by temperature induced volume-phase- and conformational transitions in DNA/PNIPA composites. Electrochem commun 2014. [DOI: 10.1016/j.elecom.2014.02.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
8
|
Xiong Y, Wei M, Wei W, Yin L, Pu Y, Liu S. Detection of DNA damage based on metal-mediated molecular beacon and DNA strands displacement reaction. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2014; 118:806-810. [PMID: 24152865 DOI: 10.1016/j.saa.2013.09.084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Revised: 09/12/2013] [Accepted: 09/25/2013] [Indexed: 06/02/2023]
Abstract
DNA hairpin structure probes are usually designed by forming intra-molecular duplex based on Watson-Crick hydrogen bonds. In this paper, a molecular beacon based on silver ions-mediated cytosine-Ag(+)-cytosine base pairs was used to detect DNA. The inherent characteristic of the metal ligation facilitated the design of functional probe and the adjustment of its binding strength compared to traditional DNA hairpin structure probes, which make it be used to detect DNA in a simple, rapid and easy way with the help of DNA strands displacement reaction. The method was sensitive and also possesses the good specificity to differentiate the single base mismatched DNA from the complementary DNA. It was also successfully applied to study the damage effect of classic genotoxicity chemicals such as styrene oxide and sodium arsenite on DNA, which was significant in food science, environmental science and pharmaceutical science.
Collapse
Affiliation(s)
- Yanxiang Xiong
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, Jiangsu Province, PR China
| | | | | | | | | | | |
Collapse
|
9
|
Wasalathanthri DP, Malla S, Bist I, Tang CK, Faria RC, Rusling JF. High-throughput metabolic genotoxicity screening with a fluidic microwell chip and electrochemiluminescence. LAB ON A CHIP 2013; 13:4554-62. [PMID: 24113555 PMCID: PMC3901045 DOI: 10.1039/c3lc50698c] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
A high throughput electrochemiluminescent (ECL) chip was fabricated and integrated into a fluidic system for screening toxicity-related chemistry of drug and pollutant metabolites. The chip base is conductive pyrolytic graphite onto which are printed 64 microwells capable of holding one-μL droplets. Films combining DNA, metabolic enzymes and an ECL-generating ruthenium metallopolymer (Ru(II)PVP) are fabricated in these microwells. The system runs metabolic enzyme reactions, and subsequently detects DNA damage caused by reactive metabolites. The performance of the chip was tested by measuring DNA damage caused by metabolites of the well-known procarcinogen benzo[a]pyrene (B[a]P). Liver microsomes and cytochrome P450 (cyt P450) enzymes were used with and without epoxide hydrolase (EH), a conjugative enzyme required for multi-enzyme bioactivation of B[a]P. DNA adduct formation was confirmed by determining specific DNA-metabolite adducts using similar films of DNA/enzyme on magnetic bead biocolloid reactors, hydrolyzing the DNA, and analyzing by capillary liquid chromatography-mass spectrometry (CapLC-MS/MS). The fluidic chip was also used to measure IC50-values of inhibitors of cyt P450s. All results show good correlation with reported enzyme activity and inhibition assays.
Collapse
|
10
|
Affiliation(s)
- Natalia Tretyakova
- Department of Medicinal Chemistry, University of Minnesota, Minneapolis, Minnesota 55455, USA.
| | | | | |
Collapse
|
11
|
Toxicokinetics of acrylamide in primary rat hepatocytes: coupling to glutathione is faster than conversion to glycidamide. Arch Toxicol 2013; 87:1545-56. [DOI: 10.1007/s00204-013-1054-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2013] [Accepted: 03/26/2013] [Indexed: 01/31/2023]
|
12
|
Wasalathanthri DP, Faria RC, Malla S, Joshi AA, Schenkman JB, Rusling JF. Screening reactive metabolites bioactivated by multiple enzyme pathways using a multiplexed microfluidic system. Analyst 2013; 138:171-8. [PMID: 23095952 PMCID: PMC3509269 DOI: 10.1039/c2an35993f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
A multiplexed, microfluidic platform to detect reactive metabolites is described, and its performance is illustrated for compounds metabolized by oxidative and bioconjugation enzymes in multi-enzyme pathways to mimic natural human drug metabolism. The device features four 8-electrode screen printed carbon arrays coated with thin films of DNA, a ruthenium-polyvinylpyridine (RuPVP) catalyst, and multiple enzyme sources including human liver microsomes (HLM), cytochrome P450 (cyt P450) 1B1 supersomes, microsomal epoxide hydrolase (EH), human S9 liver fractions (Hs9) and N-acetyltransferase (NAT). Arrays are arranged in parallel to facilitate multiple compound screening, enabling up to 32 enzyme reactions and measurements in 20-30 min. In the first step of the assay, metabolic reactions are achieved under constant flow of oxygenated reactant solutions by electrode driven natural catalytic cycles of cyt P450s and cofactor-supported bioconjugation enzymes. Reactive metabolites formed in the enzyme reactions can react with DNA. Relative DNA damage is measured in the second assay step using square wave voltammetry (SWV) with RuPVP as catalyst. Studies were done on chemicals known to require metabolic activation to induce genotoxicity, and results reproduced known features of metabolite DNA-reactivity for the test compounds. Metabolism of benzo[a]pyrene (B[a]P) by cyt P450s and epoxide hydrolase showed an enhanced relative DNA damage rate for DNA compared to cyt P450s alone. DNA damage rates for arylamines by pathways featuring both oxidative and conjugative enzymes at pH 7.4 gave better correlation with rodent genotoxicity metric TD(50). Results illustrate the broad utility of the reactive metabolite screening device.
Collapse
Affiliation(s)
| | - Ronaldo C. Faria
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Departamento de Química, Universidade Federal de São Carlos, São Carlos, SP, Brazil
| | - Spundana Malla
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Amit A. Joshi
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - John B. Schenkman
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032, United States
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Departamento de Química, Universidade Federal de São Carlos, São Carlos, SP, Brazil
- NationalUniversity of Ireland at Galway, Ireland
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032, United States
| |
Collapse
|
13
|
Zhou J, Lu Q, Tong Y, Wei W, Liu S. Detection of DNA damage by using hairpin molecular beacon probes and graphene oxide. Talanta 2012; 99:625-30. [DOI: 10.1016/j.talanta.2012.06.049] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2012] [Revised: 06/12/2012] [Accepted: 06/20/2012] [Indexed: 11/25/2022]
|
14
|
Hvastkovs EG, Schenkman JB, Rusling JF. Metabolic toxicity screening using electrochemiluminescence arrays coupled with enzyme-DNA biocolloid reactors and liquid chromatography-mass spectrometry. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2012; 5:79-105. [PMID: 22482786 PMCID: PMC3399491 DOI: 10.1146/annurev.anchem.111808.073659] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
New chemicals or drugs must be guaranteed safe before they can be marketed. Despite widespread use of bioassay panels for toxicity prediction, products that are toxic to a subset of the population often are not identified until clinical trials. This article reviews new array methodologies based on enzyme/DNA films that form and identify DNA-reactive metabolites that are indicators of potentially genotoxic species. This molecularly based methodology is designed in a rapid screening array that utilizes electrochemiluminescence (ECL) to detect metabolite-DNA reactions, as well as biocolloid reactors that provide the DNA adducts and metabolites for liquid chromatography-mass spectrometry (LC-MS) analysis. ECL arrays provide rapid toxicity screening, and the biocolloid reactor LC-MS approach provides a valuable follow-up on structure, identification, and formation rates of DNA adducts for toxicity hits from the ECL array screening. Specific examples using this strategy are discussed. Integration of high-throughput versions of these toxicity-screening methods with existing drug toxicity bioassays should allow for better human toxicity prediction as well as more informed decision making regarding new chemical and drug candidates.
Collapse
Affiliation(s)
- Eli G. Hvastkovs
- Department of Chemistry, East Carolina University, Greenville, North Carolina 27858;
| | - John B. Schenkman
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06269;
| | - James F. Rusling
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06269;
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269;
| |
Collapse
|
15
|
Watzek N, Böhm N, Feld J, Scherbl D, Berger F, Merz KH, Lampen A, Reemtsma T, Tannenbaum SR, Skipper PL, Baum M, Richling E, Eisenbrand G. N7-glycidamide-guanine DNA adduct formation by orally ingested acrylamide in rats: a dose-response study encompassing human diet-related exposure levels. Chem Res Toxicol 2012; 25:381-90. [PMID: 22211389 DOI: 10.1021/tx200446z] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Acrylamide (AA) is formed during the heating of food and is classified as a genotoxic carcinogen. The margin of exposure (MOE), representing the distance between the bench mark dose associated with 10% tumor incidence in rats and the estimated average human exposure, is considered to be of concern. After ingestion, AA is converted by P450 into the genotoxic epoxide glycidamide (GA). GA forms DNA adducts, primarily at N7 of guanine (N7-GA-Gua). We performed a dose-response study with AA in female Sprague-Dawley (SD) rats. AA was given orally in a single dosage of 0.1-10 000 μg/kg bw. The formation of urinary mercapturic acids and of N7-GA-Gua DNA adducts in liver, kidney, and lung was measured 16 h after application. A mean of 37.0 ± 11.5% of a given AA dose was found as mercapturic acids (MAs) in urine. MA excretion in urine of untreated controls indicated some background exposure from endogenous AA. N7-GA-Gua adduct formation was not detectable in any organ tested at 0.1 μg AA/kg bw. At a dose of 1 μg/kg bw, adducts were found in kidney (around 1 adduct/10(8) nucleotides) and lung (below 1 adduct/10(8) nucleotides) but not in liver. At 10, respectively, 100 μg/kg bw, adducts were found in all three organs, at levels close to those found at 1 μg AA/kg, covering a range of about 1-2 adducts/10(8) nucleotides. As compared to DNA adduct levels from electrophilic genotoxic agents of various origin found in human tissues, N7-GA-Gua adduct levels within the dose range of 0.1-100 μg AA/kg bw were at the low end of this human background. We propose to take the background level of DNA lesions in humans more into consideration when doing risk assessment of food-borne genotoxic carcinogens.
Collapse
Affiliation(s)
- Nico Watzek
- Department of Chemistry, Division of Food Chemistry and Toxicology, University of Kaiserslautern , Erwin-Schroedinger-Strasse 52, 67663 Kaiserslautern, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Chen XM, Su BY, Song XH, Chen QA, Chen X, Wang XR. Recent advances in electrochemiluminescent enzyme biosensors. Trends Analyt Chem 2011. [DOI: 10.1016/j.trac.2010.12.004] [Citation(s) in RCA: 102] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
17
|
Zhao L, Schenkman JB, Rusling JF. High-throughput metabolic toxicity screening using magnetic biocolloid reactors and LC-MS/MS. Anal Chem 2010; 82:10172-8. [PMID: 21090635 DOI: 10.1021/ac102317a] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
An inexpensive, high-throughput genotoxicity screening method was developed by using magnetic particles coated with cytosol/microsome/DNA films as biocolloid reactors in a 96-well plate format coupled with liquid chromatography-mass spectrometry. Incorporation of both microsomal and cytosolic enzymes in the films provides a broad spectrum of metabolic enzymes representing a range of metabolic pathways for bioactivation of chemicals. Reactive metabolites generated via this process are trapped by covalently binding to DNA in the film. The DNA is then hydrolyzed and nucleobase adducts are collected using filters in the bottom for the 96-well plate of analysis by capillary liquid chromatography-tandem mass spectrometry (LC-MS/MS). The magnetic particles facilitate simple and rapid sample preparation and workup. Major DNA adducts from ethylene dibromide, N-acetyl-2-aminofluorene and styrene were identified in proof-of-concept studies. Relative formation rates of DNA adducts correlated well with rodent genotoxicity metric TD(50) for the three compounds. This method has the potential for high-throughput genotoxicity screening, providing chemical structure information that is complementary to toxicity bioassays.
Collapse
Affiliation(s)
- Linlin Zhao
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, United States
| | | | | |
Collapse
|
18
|
Electrochemical detection of DNA damage induced by in situ generated bisphenol A radicals through electro-oxidation. Mikrochim Acta 2010. [DOI: 10.1007/s00604-010-0437-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Detection of DNA damage induced by styrene oxide in dsDNA layer-by-layer films using adriamycin as electroactive probe. Colloids Surf B Biointerfaces 2010; 76:334-9. [DOI: 10.1016/j.colsurfb.2009.11.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2008] [Revised: 11/20/2009] [Accepted: 11/23/2009] [Indexed: 11/18/2022]
|
20
|
The formation and biological significance of N7-guanine adducts. Mutat Res 2009; 678:76-94. [PMID: 19465146 DOI: 10.1016/j.mrgentox.2009.05.006] [Citation(s) in RCA: 160] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2009] [Accepted: 05/13/2009] [Indexed: 11/24/2022]
Abstract
DNA alkylation or adduct formation occurs at nucleophilic sites in DNA, mainly the N7-position of guanine. Ever since identification of the first N7-guanine adduct, several hundred studies on DNA adducts have been reported. Major issues addressed include the relationships between N7-guanine adducts and exposure, mutagenesis, and other biological endpoints. It became quickly apparent that N7-guanine adducts are frequently formed, but may have minimal biological relevance, since they are chemically unstable and do not participate in Watson Crick base pairing. However, N7-guanine adducts have been shown to be excellent biomarkers for internal exposure to direct acting and metabolically activated carcinogens. Questions arise, however, regarding the biological significance of N7-guanine adducts that are readily formed, do not persist, and are not likely to be mutagenic. Thus, we set out to review the current literature to evaluate their formation and the mechanistic evidence for the involvement of N7-guanine adducts in mutagenesis or other biological processes. It was concluded that there is insufficient evidence that N7-guanine adducts can be used beyond confirmation of exposure to the target tissue and demonstration of the molecular dose. There is little to no evidence that N7-guanine adducts or their depurination product, apurinic sites, are the cause of mutations in cells and tissues, since increases in AP sites have not been shown unless toxicity is extant. However, more research is needed to define the extent of chemical depurination versus removal by DNA repair proteins. Interestingly, N7-guanine adducts are clearly present as endogenous background adducts and the endogenous background amounts appear to increase with age. Furthermore, the N7-guanine adducts have been shown to convert to ring opened lesions (FAPy), which are much more persistent and have higher mutagenic potency. Studies in humans are limited in sample size and differences between controls and study groups are small. Future investigations should involve human studies with larger numbers of individuals and analysis should include the corresponding ring opened FAPy derivatives.
Collapse
|
21
|
Krishnan S, Bajrami B, Mani V, Pan S, Rusling JF. Comparison of DNA-Reactive Metabolites from Nitrosamine and Styrene Using Voltammetric DNA/Microsomes Sensors. ELECTROANAL 2009; 21:1005-1013. [PMID: 23100998 DOI: 10.1002/elan.200804521] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Voltammetric sensors made with films of polyions, double-stranded DNA and liver microsomes adsorbed layer-by-layer onto pyrolytic graphite electrodes were evaluated for reactive metabolite screening. This approach features simple, inexpensive screening without enzyme purification for applications in drug or environmental chemical development. Cytochrome P450 enzymes (CYPs) in the liver microsomes were activated by an NADPH regenerating system or by electrolysis to metabolize model carcinogenic compounds nitrosamine and styrene. Reactive metabolites formed in the films were trapped as adducts with nucleobases on DNA. The DNA damage was detected by square-wave voltammetry (SWV) using [Formula: see text] as a DNA-oxidation catalyst. These sensors showed a larger rate of increase in signal vs. reaction time for a highly toxic nitrosamine than for the moderately toxic styrene due to more rapid reactive metabolite-DNA adduct formation. Results were consistent with reported in vivo TD(50) data for the formation of liver tumors in rats. Analogous polyion/ liver microsome films prepared on 500 nm silica nanoparticles (nanoreactors) and reacted with nitrosamine or styrene, provided LC-MS or GC analyses of metabolite formation rates that correlated well with sensor response.
Collapse
Affiliation(s)
- Sadagopan Krishnan
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA
| | | | | | | | | |
Collapse
|
22
|
Hull DO, Bajrami B, Jansson I, Schenkman JB, Rusling JF. Characterizing metabolic inhibition using electrochemical enzyme/DNA biosensors. Anal Chem 2009; 81:716-24. [PMID: 19099359 PMCID: PMC2684828 DOI: 10.1021/ac802179s] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Studies of metabolic enzyme inhibition are necessary in drug development and toxicity investigations as potential tools to limit or prevent appearance of deleterious metabolites formed, for example, by cytochrome (cyt) P450 enzymes. In this paper, we evaluate the use of enzyme/DNA toxicity biosensors as tools to investigate enzyme inhibition. We have examined DNA damage due to cyt P450cam metabolism of styrene using DNA/enzyme films on pyrolytic graphite (PG) electrodes monitored via Ru(bpy)(3)(2+)-mediated DNA oxidation. Styrene metabolism initiated by hydrogen peroxide was evaluated with and without the inhibitors, imidazole, imidazole-4-acetic acid, and sulconazole (in micromolar range) to monitor DNA damage inhibition. The initial rates of DNA damage decreased with increased inhibitor concentrations. Linear and nonlinear fits of Michaelis-Menten inhibition models were used to determine apparent inhibition constants (K(I)*) for the inhibitors. Elucidation of the best fitting inhibition model was achieved by comparing correlation coefficients and the sum of the square of the errors (SSE) from each inhibition model. Results confirmed the utility of the enzyme/DNA biosensor for metabolic inhibition studies. A simple competitive inhibition model best approximated the data for imidazole, imidazole-4-acetic acid and sulconazole with K(I)* of 268.2, 142.3, and 204.2 microM, respectively.
Collapse
Affiliation(s)
- Dominic O. Hull
- Department of Chemistry and Institute of Materials Science, 55 N. Eagleville Road, University of Connecticut, Storrs, Connecticut 06269
| | - Besnik Bajrami
- Department of Chemistry and Institute of Materials Science, 55 N. Eagleville Road, University of Connecticut, Storrs, Connecticut 06269
| | - Ingela Jansson
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| | - John B. Schenkman
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| | - James F. Rusling
- Department of Chemistry and Institute of Materials Science, 55 N. Eagleville Road, University of Connecticut, Storrs, Connecticut 06269
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| |
Collapse
|
23
|
Doak SH, Brüsehafer K, Dudley E, Quick E, Johnson G, Newton RP, Jenkins GJS. No-observed effect levels are associated with up-regulation of MGMT following MMS exposure. Mutat Res 2008; 648:9-14. [PMID: 18992265 DOI: 10.1016/j.mrfmmm.2008.09.016] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2008] [Revised: 07/31/2008] [Accepted: 09/04/2008] [Indexed: 05/27/2023]
Abstract
The alkylating agents methyl methanesulphonate (MMS) and ethyl methanesulphonate (EMS) have non-linear dose-response curves, with a no-observed effect level (NOEL) and a lowest observed effect level (LOEL) for both gross chromosomal damage and mutagenicity. However, the biological mechanism responsible for the NOEL has yet to be identified. A strong candidate is DNA repair as it may be able to efficiently remove alkyl adducts at low doses resulting in a NOEL, but at higher doses fails to fully remove all lesions due to saturation of enzymatic activity resulting in a LOEL and subsequent linear increases in mutagenicity. We therefore assessed the transcriptional status of N-methylpurine-DNA glycoslase (MPG) and O(6)-methylguanine DNA methyltransferase (MGMT), which represent the first line of defence following exposure to alkylating agents through the respective enzymatic removal of N7-alkylG and O(6)-alkylG. The relative MPG and MGMT gene expression profiles were assessed by real-time RT-PCR following exposure to 0-2 microg/ml MMS for 1-24h. MPG expression remained fairly steady, but in contrast significant up-regulation of MGMT was observed when cells were treated with 0.5 and 1.0 microg/ml MMS for 4h (2.5- and 6.5-fold increases respectively). These doses lie within the NOEL for MMS mutagenicity (LOEL is 1.25 microg/ml), thus this boost in MGMT expression at low doses may be responsible for efficiently repairing O(6)methylG lesions and creating the non-linear response for mutations. However, as the LOEL for MMS clastogenicity is 0.85 microg/ml, O(6)-alkylG is unlikely to be responsible for the clastogenicity observed at these concentrations. Consequently, at low doses N7-methylG is possibly the predominant cause of MMS clastogenicity, while O(6)-methylG is more likely to be responsible for MMS mutagenicity, with MGMT up-regulation playing a key role in removal of O(6)-alkylG lesions before they are fixed as permanent point mutations, resulting in non-linear dose-responses for direct acting genotoxins.
Collapse
Affiliation(s)
- Shareen H Doak
- Institute of Life Science, School of Medicine, Swansea University, Singleton Park, Swansea, Wales, UK.
| | | | | | | | | | | | | |
Collapse
|
24
|
Krishnan S, Hvastkovs EG, Bajrami B, Schenkman JB, Rusling JF. Human cyt P450 mediated metabolic toxicity of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) evaluated using electrochemiluminescent arrays. MOLECULAR BIOSYSTEMS 2008; 5:163-9. [PMID: 19156262 DOI: 10.1039/b815910f] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Electrochemiluminescent (ECL) arrays containing polymer ([Ru(bpy)(2)(PVP)(10)](2+), PVP = polyvinylpyridine), DNA, and selected enzymes were employed to elucidate cytochrome (cyt) P450 dependent metabolism of the tobacco specific carcinogen, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK). Bioactivated NNK metabolites formed upon H(2)O(2)-enzymatic activation were captured as DNA adducts and detected simultaneously from 36 spot arrays by capturing and quantifying emitted ECL with an overhead CCD camera. Increased ECL emission was dependent on NNK exposure time. Of the enzymes tested, the activity toward NNK bioactivation was cyt P450 1A2 > 2E1 > 1B1 approximately chloroperoxidase (CPO) > myoglobin (Mb) in accordance with reported in vivo studies. Cyt P450/polyion films were also immobilized on 500 nm diameter silica nanospheres for product analysis by LC-MS. Analysis of the nanosphere film reaction media provided ECL array validation and quantitation of the bioactivated NNK hydrolysis product 4-hydroxy-1-(3-pyridyl)-1-butanone (HPB) confirming production of reactive metabolites in the films. Chemical screening in this fashion allows rapid clarification of enzymes responsible for genotoxic activation as well as offering insight into cyt P450-related toxicity and mechanisms.
Collapse
Affiliation(s)
- Sadagopan Krishnan
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA
| | | | | | | | | |
Collapse
|
25
|
Krishnan S, Hvastkovs EG, Bajrami B, Choudhary D, Schenkman JB, Rusling JF. Synergistic metabolic toxicity screening using microsome/DNA electrochemiluminescent arrays and nanoreactors. Anal Chem 2008; 80:5279-85. [PMID: 18563913 PMCID: PMC3483639 DOI: 10.1021/ac800763r] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Platforms based on thin enzyme/DNA films were used in two-tier screening of chemicals for reactive metabolites capable of producing toxicity. Microsomes were used for the first time as sources of cytochrome (cyt) P450 enzymes in these devices. Initial rapid screening involved electrochemiluminescent (ECL) arrays featuring spots containing ruthenium poly(vinylpyridine), DNA, and rat liver microsomes or bicistronically expressed human cyt P450 2E1 (h2E1). Cyt P450 enzymes were activated via the NADPH/reductase cycle. When bioactivation of substrates in the films gives reactive metabolites, they are trapped by covalent attachment to DNA bases. The rate of increase in ECL with enzyme reaction time reflects relative DNA damage rates. "Toxic hits" uncovered by the array were studied in structural detail by using enzyme/DNA films on silica nanospheres as "nanoreactors" to provide nucleobase adducts from reactive metabolites. The utility of this synergistic approach was demonstrated by estimating relative DNA damage rates of three mutagenic N-nitroso compounds and styrene. Relative enzyme turnover rates for these compounds using ECL arrays and LC-UV-MS correlated well with TD 50 values for liver tumor formation in rats. Combining ECL array and nanoreactor/LC-MS technologies has the potential for rapid, high-throughput, cost-effective screening for reactive metabolites and provides chemical structure information that is complementary to conventional toxicity bioassays.
Collapse
|
26
|
Fundador EV, Choudhary D, Schenkman JB, Rusling JF. Accurate DNA fragment sizing by capillary electrophoresis with laser-induced fluorescence array for detection of sequence specificity of DNA damage. Anal Chem 2008; 80:2212-21. [PMID: 18266391 DOI: 10.1021/ac702265b] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Cancer has been linked to mutations within specific codons in genes that code for critical biomolecules such as tumor suppressor proteins (e.g., p53). Activated metabolites like benzo[a]pyrenediol epoxide act on preferred nucleotide sequences of DNA, and such mutations have been identified in cancers. DNA reaction site identification depends on accurate analysis of oligonucleotide fragment sizes produced by strand breakage at the damaged sites. Herein, we report a new method for DNA fragment sizing using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF). Absolute sizing accuracy and speed are achieved by utilizing a CE-LIF array with two-color fluorescence detection. Accuracy depends on correcting results with commercial standards by referring them to primary standards with the same sequences and identical labels as sample fragments. The method is demonstrated by detection of a [...GGCGCGCAG...] G reaction site for styrene oxide on an oligonucleotide representing the CYP1B1 gene. This approach avoids the need for radioactive isotopes and is less labor intensive and faster than the alternative PAGE with (32)P end labeling.
Collapse
Affiliation(s)
- Erwin V Fundador
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, USA
| | | | | | | |
Collapse
|
27
|
Bajrami B, Hvastkovs EG, Jensen GC, Schenkman JB, Rusling JF. Enzyme−DNA Biocolloids for DNA Adduct and Reactive Metabolite Detection by Chromatography−Mass Spectrometry. Anal Chem 2008; 80:922-32. [DOI: 10.1021/ac702025f] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Besnik Bajrami
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, and Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| | - Eli G. Hvastkovs
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, and Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| | - Gary C. Jensen
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, and Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| | - John B. Schenkman
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, and Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, and Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032
| |
Collapse
|
28
|
Rusling JF, Hvastkovs EG, Hull DO, Schenkman JB. Biochemical applications of ultrathin films of enzymes, polyions and DNA. Chem Commun (Camb) 2008:141-54. [PMID: 18092072 PMCID: PMC3473181 DOI: 10.1039/b709121b] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This feature article summarizes recent applications of ultrathin films of enzymes and DNA assembled layer-by-layer (LbL). Using examples mainly from our own research, we focus on systems developed for biocatalysis and biosensors for toxicity screening. Enzyme-poly(L-lysine) (PLL) films, especially when stabilized by crosslinking, can be used for biocatalysis at unprecedented high temperatures or in acidic or basic solutions on electrodes or sub-micron sized beads. Such films have bright prospects for chiral synthesis and biofuel cells. Excellent bioactivity and retention of enzyme structure in these films facilitates their use in detailed kinetic studies. Biosensors and arrays employing DNA-enzyme films show great promise in predicting genotoxicity of new drug and chemical product candidates. These devices combine metabolic biocatalysis, reactive metabolite-DNA reactions, and DNA damage detection. Catalytic voltammetry or electrochemiluminescence (ECL) can be used for high throughput arrays utilizing multiple LbL "spots" of DNA, enzyme and metallopolymer. DNA-enzyme films can also be used to produce nucleobase adduct toxicity biomarkers for detection by LC-MS. These approaches provide valuable high throughput tools for drug and chemical product development and toxicity prediction.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.
| | | | | | | |
Collapse
|
29
|
So M, Hvastkovs EG, Bajrami B, Schenkman JB, Rusling JF. Electrochemical genotoxicity screening for arylamines bioactivated by N-acetyltransferase. Anal Chem 2008; 80:1192-200. [PMID: 18189370 DOI: 10.1021/ac701781y] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Genotoxicity screening sensors that measure DNA damage from metabolism of arylamines were developed and evaluated. The sensors feature ultrathin films containing DNA and N-acetyltransferase (NAT) on pyrolytic graphite (PG) electrodes. NAT in the film catalyzed the conversion of the arylamine 2-aminofluorene (2-AF) to 2-acetylaminofluorene (2-AAF) by acetyl coenzyme A (AcCoA) dependent N-acetylation, as verified by liquid chromatography. DNA damage in the films from exposure to reactive 2-AF metabolites was measured subsequent to the enzyme reaction using catalytic voltammetric oxidation with Ru(bpy)32+. Square wave voltammetric (SWV) peaks increased with enzyme reaction time, and relative DNA damage rates at pH 5.8 were measured within 2 min. Control incubations of DNA/NAT films without AcCoA gave no significant sensor response. CapLC-MS/MS analysis of 2-AAF/DNA reaction products was consistent with 2-AF-guanine adducts formed in the films. DNA damage occurred more rapidly under weakly acidic conditions (pH 5.5-5.8) than at neutral pH, suggesting that genotoxicity from arylamine metabolism by NAT could be more significant in slightly acidic environments.
Collapse
Affiliation(s)
- Minjeong So
- Department of Chemistry, 55 North Eagleville Road, University of Connecticut, Storrs, CT 06269, USA
| | | | | | | | | |
Collapse
|
30
|
So M, Hvastkovs EG, Schenkman JB, Rusling JF. Electrochemiluminescent/voltammetric toxicity screening sensor using enzyme-generated DNA damage. Biosens Bioelectron 2007; 23:492-8. [PMID: 17825549 PMCID: PMC2323599 DOI: 10.1016/j.bios.2007.06.017] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2007] [Revised: 04/27/2007] [Accepted: 06/19/2007] [Indexed: 11/24/2022]
Abstract
Simultaneous optical and voltammetric detection of bioactivated genotoxicity is reported for the first time employing ultrathin films of DNA, model metabolic enzymes, and electrochemiluminescence (ECL) generating metallopolymer [Ru(bpy)2PVP10]2+ on pyrolytic graphite (PG) electrodes. Cytochrome P450cam and myoglobin were used as model monoxygenase enzymes to mimic in vivo processes. Sensor film growth and component amounts were monitored using a quartz crystal microbalance (QCM). Subsequent to the enzyme reaction, DNA damage in the sensor films was measured simultaneously using a simple apparatus combining a standard voltammetry cell coupled with an optical fiber and photomultiplier tube. The model enzyme reaction converted styrene to styrene oxide, which reacts with DNA nucleobases. ECL and SWV signals increased with enzyme reaction time on the scale of several min, and provided relative enzyme turnover rates for DNA damage suitable for toxicity screening applications. Within 1 min, the sensor detects approximately 3 damaged bases per 10,000 DNA bases using this simultaneous detection.
Collapse
Affiliation(s)
- Minjeong So
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | | | | | | |
Collapse
|
31
|
Alzaga R, Ryan RW, Taylor-Worth K, Lipczynski AM, Szucs R, Sandra P. A generic approach for the determination of residues of alkylating agents in active pharmaceutical ingredients by in situ derivatization–headspace–gas chromatography–mass spectrometry. J Pharm Biomed Anal 2007; 45:472-9. [PMID: 17719195 DOI: 10.1016/j.jpba.2007.07.017] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2007] [Revised: 07/09/2007] [Accepted: 07/14/2007] [Indexed: 10/23/2022]
Abstract
A simple, reliable and fast procedure for the simultaneous determination of residues of some common alkylating agents (AAs), such as mesylates, besylates, tosylates and sulfates, employed in drug synthesis, has been developed by in situ derivatization-headspace-gas chromatography-mass spectrometry. Pentafluorothiophenol is used as a derivatizing agent in different water/dimethyl sulfoxide ratios. Compared to former analytical procedures, this approach returns improvements in analysis time, selectivity, analyte stability and method sensitivity (LOD=0.11 microgg(-1) for methyl tosylate). The method exhibits low matrix dependence, excellent accuracy, precision (R.S.D.=2.8-10% range at 1 microgg(-1)) and robustness through the use of deuterated internal standards. Knowledge of the synthetic route allows a targeted approach to the determination of specific AAs since the procedure does not distinguish between acid species. The procedure was successfully applied to different pharmaceutical matrixes, and is particularly suitable for routine analysis with high sample throughput.
Collapse
Affiliation(s)
- Roberto Alzaga
- Pfizer Analytical Research Centre, Ghent University, Krijgslaan 281 S4-bis, B-9000 Ghent, Belgium
| | | | | | | | | | | |
Collapse
|
32
|
Paixão TRLC, Garcia CCM, Medeiros MHG, Bertotti M. Flow Injection Amperometric Detection of 2‘-Deoxyguanosine at a Ruthenium Oxide Hexacyanoferrate Modified Electrode. Anal Chem 2007; 79:5392-8. [PMID: 17552494 DOI: 10.1021/ac070490e] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A ruthenium oxide hexacyanoferrate (RuOHCF) modified electrode was developed. Hydrodynamic voltammetry was employed to demonstrate the remarkable electrocatalytic activity toward the oxidation of 2'-deoxyguanosine. The RuOHCF modified electrode was used as amperometric detector for 2'-deoxyguanosine determination in a FIA apparatus. The influence of various experimental conditions was explored for optimum analytical performance, and at these experimental conditions, the method exhibited a linear response range to 2'-deoxyguanosine extending from 3.8 to 252 micromol L(-1) with detection limit of 94 nmol L(-1). Applications in DNA samples were examined, and the results for determination of 2'-deoxyguanosine were in good agreement with those obtained by HPLC analysis. Studies on the kinetics of the in vitro consumption of 2'-deoxyguanosine by acetaldehyde were also performed.
Collapse
|
33
|
Hvastkovs EG, So M, Krishnan S, Bajrami B, Tarun M, Jansson I, Schenkman JB, Rusling JF. Electrochemiluminescent arrays for cytochrome P450-activated genotoxicity screening. DNA damage from benzo[a]pyrene metabolites. Anal Chem 2007; 79:1897-906. [PMID: 17261025 PMCID: PMC2323608 DOI: 10.1021/ac061975q] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Arrays suitable for genotoxicity screening are reported that generate metabolites from cytochrome P450 enzymes (CYPs) in thin-film spots. Array spots containing DNA, various human cyt P450s, and electrochemiluminescence (ECL) generating metallopolymer [Ru(bpy)2PVP10]2+ were exposed to H2O2 to activate the enzymes. ECL from all spots was visualized simultaneously using a CCD camera. Using benzo[a]pyrene as a test substrate, enzyme activity for producing DNA damage in the arrays was found in the order CYP1B1 > CYP1A2 > CYP1A1 > CYP2E1 > myoglobin, the same as the order of their metabolic activity. Thus, these arrays estimate the relative propensity of different enzymes to produce genotoxic metabolites. This is the first demonstration of ECL arrays for high-throughput in vitro genotoxicity screening.
Collapse
|
34
|
Zhang Y, Hu N. Cyclic voltammetric detection of chemical DNA damage induced by styrene oxide in natural dsDNA layer-by-layer films using methylene blue as electroactive probe. Electrochem commun 2007. [DOI: 10.1016/j.elecom.2006.08.032] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
35
|
Tarun M, Bajrami B, Rusling JF. Genotoxicity Screening Using Biocatalyst/DNA Films and Capillary LC−MS/MS. Anal Chem 2005; 78:624-7. [PMID: 16408950 DOI: 10.1021/ac0517996] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Detection of DNA adducts can serve as a basis for genotoxicty screening of new chemicals and drugs. We report here a simple, sensitive procedure for this purpose using films containing DNA and a biocatalyst to mimic the metabolic action of human liver cytochrome P450s. DNA adducts formed from an in-situ-generated toxic metabolite (styrene oxide) were detected at subpicomole levels after neutral thermal hydrolysis of the DNA films and analysis with capillary liquid chromatography with on-line column preconcentration and MS/MS detection. An on-line column switching system allowed for increased sample loading volume and analyte preconcentration. This approach provides an estimate of the relative rate of DNA damage.
Collapse
|
36
|
Singh R, Farmer PB. Liquid chromatography-electrospray ionization-mass spectrometry: the future of DNA adduct detection. Carcinogenesis 2005; 27:178-96. [PMID: 16272169 DOI: 10.1093/carcin/bgi260] [Citation(s) in RCA: 159] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Over the past 40 years considerable emphasis has been placed on the development of accurate and sensitive methods for the detection and quantitation of DNA adducts. The formation of DNA adducts resulting from the covalent interaction of genotoxic carcinogens with DNA, derived from exogenous and endogenous sources, either directly or following metabolic activation, can if not repaired lead to mutations in critical genes such as those involved in the regulation of cellular growth and subsequent development of cancer. The major analytical challenge has been to detect levels of DNA adducts at the level of 0.1-1 adducts per 10(8) unmodified DNA bases using only low microgram amounts of DNA, and with high specificity and accuracy, in humans exposed to genotoxic carcinogens derived from occupational, environmental, dietary and life-style sources. In this review we will highlight the merits as well as discuss the progress made by liquid chromatography coupled to electrospray ionization mass spectrometry as a method for DNA adduct detection.
Collapse
Affiliation(s)
- Rajinder Singh
- Cancer Biomarkers and Prevention Group, Biocentre, University of Leicester, University Road, Leicester LE1 7RH, UK.
| | | |
Collapse
|
37
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2005; 40:1390-401. [PMID: 16237664 DOI: 10.1002/jms.811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
|
38
|
Yang J, Wang B, Rusling JF. Genotoxicity sensor response correlated with DNA nucleobase damage rates measured by LC-MS. MOLECULAR BIOSYSTEMS 2005; 1:251-9. [PMID: 16880989 DOI: 10.1039/b506111c] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Responses from "reagentless" DNA-based electrochemical toxicity sensors to DNA alkylating agents styrene oxide (SO), diepoxybutane (DEB), and methyl methanesulfonate (MMS) were compared to formation rates of total alkylated nucleobases in DNA measured by LC-UV-MS. Sensors utilized a catalytic metallopolymer in DNA films previously exposed to the damage agents. To achieve adequate sensitivity, LC-UV-MS analyses were done on DNA in solution reacted with the damage agents, and subsequently hydrolyzed to nucleosides with enzymes. Sensor response correlated well with nucleobase-adduct formation rates obtained by the molecule-specific analyses. Results confirm that the metallopolymer-DNA film sensors can be used to estimate relative DNA damage rates from nucleobase adduct-forming chemicals. Results from both methods correlated well with animal genotoxicity as estimated by TDL(o) values, the lowest dose producing carcinogenicity, in mice and rats. These sensors should be useful for rapid, inexpensive screening of moderately and severely genotoxic new chemicals.
Collapse
Affiliation(s)
- Jing Yang
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA
| | | | | |
Collapse
|
39
|
Sensors for Genotoxicity and Oxidized DNA. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/s1871-0069(05)01013-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|