1
|
Chen X, Leary TF, Maldarelli C. Transport of biomolecules to binding partners displayed on the surface of microbeads arrayed in traps in a microfluidic cell. BIOMICROFLUIDICS 2017; 11:014101. [PMID: 28096941 PMCID: PMC5218969 DOI: 10.1063/1.4973247] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 12/13/2016] [Indexed: 05/15/2023]
Abstract
Arrays of probe molecules integrated into a microfluidic cell are utilized as analytical tools to screen the binding interactions of the displayed probes against a target molecule. These assay platforms are useful in enzyme or antibody discovery, clinical diagnostics, and biosensing, as their ultraminiaturized design allows for high sensitivity and reduced consumption of reagents and target. We study here a platform in which the probes are first grafted to microbeads which are then arrayed in the microfluidic cell by capture in a trapping course. We examine a course which consists of V-shaped, half-open enclosures, and study theoretically and experimentally target mass transfer to the surface probes. Target binding is a two step process of diffusion across streamlines which convect the target over the microbead surface, and kinetic conjugation to the surface probes. Finite element simulations are obtained to calculate the target surface concentration as a function of time. For slow convection, large diffusive gradients build around the microbead and the trap, decreasing the overall binding rate. For rapid convection, thin diffusion boundary layers develop along the microbead surface and within the trap, increasing the binding rate to the idealized limit of untrapped microbeads in a channel. Experiments are undertaken using the binding of a target, fluorescently labeled NeutrAvidin, to its binding partner biotin, on the microbead surface. With the simulations as a guide, we identify convective flow rates which minimize diffusion barriers so that the transport rate is only kinetically determined and measure the rate constant.
Collapse
Affiliation(s)
- Xiaoxiao Chen
- Department of Chemical Engineering, Benjamin Levich Institute, City College of the City University of New York , New York, New York 10031, USA
| | - Thomas F Leary
- Department of Chemical Engineering, Benjamin Levich Institute, City College of the City University of New York , New York, New York 10031, USA
| | - Charles Maldarelli
- Department of Chemical Engineering, Benjamin Levich Institute, City College of the City University of New York , New York, New York 10031, USA
| |
Collapse
|
2
|
Kulla E, Chou J, Simmons G, Wong J, McRae MP, Patel R, Floriano PN, Christodoulides N, Leach RJ, Thompson IM, McDevitt JT. Enhancement of performance in porous bead-based microchip sensors: Effects of chip geometry on bio-agent capture. RSC Adv 2015; 5:48194-48206. [PMID: 26097696 PMCID: PMC4470495 DOI: 10.1039/c5ra07910a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Measuring low concentrations of clinically-important biomarkers using porous bead-based lab-on-a-chip (LOC) platforms is critical for the successful implementation of point-of-care (POC) devices. One way to meet this objective is to optimize the geometry of the bead holder, referred to here as a micro-container. In this work, two geometric micro-containers were explored, the inverted pyramid frustum (PF) and the inverted clipped pyramid frustum (CPF). Finite element models of this bead array assay system were developed to optimize the micro-container and bead geometries for increased pressure, to increase analyte capture in porous bead-based fluorescence immunoassays. Custom micro-milled micro-container structures containing an inverted CPF geometry resulted in a 28% reduction in flow-through regions from traditional anisotropically-etched pyramidal geometry derived from Si-111 termination layers. This novel "reduced flow-through" design resulted in a 33% increase in analyte penetration into the bead and twofold increase in fluorescence signal intensity as demonstrated with C-Reactive Protein (CRP) antigen, an important biomarker of inflammation. A consequent twofold decrease in the limit of detection (LOD) and the limit of quantification (LOQ) of a proof-of-concept assay for the free isoform of Prostate-Specific Antigen (free PSA), an important biomarker for prostate cancer detection, is also presented. Furthermore, a 53% decrease in the bead diameter is shown to result in a 160% increase in pressure and 2.5-fold increase in signal, as estimated by COMSOL models and confirmed experimentally by epi-fluorescence microscopy. Such optimizations of the bead micro-container and bead geometries have the potential to significantly reduce the LODs and reagent costs for spatially programmed bead-based assay systems of this type.
Collapse
Affiliation(s)
- Eliona Kulla
- Department of Chemistry, Rice University, Houston, Texas 77005
| | - Jie Chou
- Department of Bioengineering, Rice University, Houston, Texas 77005
| | - Glennon Simmons
- Department of Chemistry, Rice University, Houston, Texas 77005
- Department of Bioengineering, Rice University, Houston, Texas 77005
| | - Jorge Wong
- Department of Chemistry, Rice University, Houston, Texas 77005
- Department of Bioengineering, Rice University, Houston, Texas 77005
| | - Michael P. McRae
- Department of Bioengineering, Rice University, Houston, Texas 77005
| | - Rushi Patel
- Department of Bioengineering, Rice University, Houston, Texas 77005
| | | | - Nicolaos Christodoulides
- Department of Chemistry, Rice University, Houston, Texas 77005
- Department of Bioengineering, Rice University, Houston, Texas 77005
| | - Robin J. Leach
- Urology, University of Texas Health Science Center at San Antonio, Texas 78229
| | - Ian M. Thompson
- Urology, University of Texas Health Science Center at San Antonio, Texas 78229
| | - John T. McDevitt
- Department of Chemistry, Rice University, Houston, Texas 77005
- Department of Bioengineering, Rice University, Houston, Texas 77005
| |
Collapse
|
3
|
Chou J, Li LE, Kulla E, Christodoulides N, Floriano PN, McDevitt JT. Effects of sample delivery on analyte capture in porous bead sensors. LAB ON A CHIP 2012; 12:5249-56. [PMID: 23117481 PMCID: PMC3541674 DOI: 10.1039/c2lc40752c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Sample delivery is a crucial aspect of point-of-care applications where sample volumes need to be low and assay times short, while providing high analytical and clinical sensitivity. In this paper, we explore the influence of the factors surrounding sample delivery on analyte capture in an immunoassay-based sensor array manifold of porous beads resting in individual wells. We model using computational fluid dynamics and a flow-through device containing beads sensitized specifically to C-reactive protein (CRP) to explore the effects of volume of sample, rate of sample delivery, and use of recirculation vs. unilateral delivery on the effectiveness of the capture of CRP on and within the porous bead sensor. Rate of sample delivery lends to the development of a time-dependent, shrinking depletion region around the bead exterior. Our findings reveal that at significantly high rates of delivery, unique to porous bead substrates, capture at the rim of the bead is reaction-limited, while capture in the interior of the bead is transport-limited. While the fluorescence signal results from the aggregate of captured material throughout the bead, multiple kinetic regimes exist within the bead. Further, under constant pressure conditions dictated by the array architecture, we reveal the existence of an optimal flow rate that generates the highest signal, under point-of-care constraints of limited-volume and limited-time. When high sensitivity is needed, recirculation can be implemented to overcome the analyte capture limitations due to volume and time constraints. Computational simulations agree with experimental results performed under similar conditions.
Collapse
Affiliation(s)
- Jie Chou
- Department of Bioengineering, Rice University, Houston, Texas77005, USA
| | | | | | | | | | | |
Collapse
|
4
|
Chou J, Wong J, Christodoulides N, Floriano PN, Sanchez X, McDevitt J. Porous bead-based diagnostic platforms: bridging the gaps in healthcare. SENSORS (BASEL, SWITZERLAND) 2012; 12:15467-99. [PMID: 23202219 PMCID: PMC3522972 DOI: 10.3390/s121115467] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2012] [Revised: 10/25/2012] [Accepted: 11/01/2012] [Indexed: 01/11/2023]
Abstract
Advances in lab-on-a-chip systems have strong potential for multiplexed detection of a wide range of analytes with reduced sample and reagent volume; lower costs and shorter analysis times. The completion of high-fidelity multiplexed and multiclass assays remains a challenge for the medical microdevice field; as it struggles to achieve and expand upon at the point-of-care the quality of results that are achieved now routinely in remote laboratory settings. This review article serves to explore for the first time the key intersection of multiplexed bead-based detection systems with integrated microfluidic structures alongside porous capture elements together with biomarker validation studies. These strategically important elements are evaluated here in the context of platform generation as suitable for near-patient testing. Essential issues related to the scalability of these modular sensor ensembles are explored as are attempts to move such multiplexed and multiclass platforms into large-scale clinical trials. Recent efforts in these bead sensors have shown advantages over planar microarrays in terms of their capacity to generate multiplexed test results with shorter analysis times. Through high surface-to-volume ratios and encoding capabilities; porous bead-based ensembles; when combined with microfluidic elements; allow for high-throughput testing for enzymatic assays; general chemistries; protein; antibody and oligonucleotide applications.
Collapse
Affiliation(s)
- Jie Chou
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
| | - Jorge Wong
- Department of Chemistry, University of Texas at Austin, 1 University Station A5300, Austin, TX 78712, USA; E-Mail:
| | - Nicolaos Christodoulides
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| | - Pierre N. Floriano
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| | - Ximena Sanchez
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| | - John McDevitt
- Department of Bioengineering, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA; E-Mails: (J.C.); (N.C.); (P.N.F.); (X.S.)
- Department of Chemistry, Rice University, 6100 Main St MS-142, Houston, TX 77005, USA
| |
Collapse
|
5
|
Du N, Chou J, Kulla E, Floriano PN, Christodoulides N, McDevitt JT. A disposable bio-nano-chip using agarose beads for high performance immunoassays. Biosens Bioelectron 2011; 28:251-6. [PMID: 21852104 DOI: 10.1016/j.bios.2011.07.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2011] [Revised: 07/07/2011] [Accepted: 07/13/2011] [Indexed: 11/18/2022]
Abstract
This article reports on the fabrication of a disposable bio-nano-chip (BNC), a microfluidic device composed of polydimethylsiloxane (PDMS) and thiolene-based optical epoxy which is both cost-effective and suitable for high performance immunoassays. A novel room temperature (RT) bonding technique was utilized so as to achieve irreversible covalent bonding between PDMS and thiolene-based epoxy layers, while at the same time being compatible with the insertion of agarose bead sensors, selectively arranged in an array of pyramidal microcavities replicated in the thiolene thin film layer. In the sealed device, the bead-supporting epoxy film is sandwiched between two PDMS layers comprising of fluidic injection and drain channels. The agarose bead sensors used in the device are sensitized with anti-C-reactive protein (CRP) antibody, and a fluorescent sandwich-type immunoassay was run to characterize the performance of this device. Computational fluid dynamics (CFD) was used based on the device specifications to model the bead penetration. Experimental data revealed analyte penetration of the immunocomplex to 100 μm into the 280 μm diameter agarose beads, which correlated well with the simulation. A dose-response curve was obtained and the linear dynamic range of the assay was established over 1 ng/mL to 50 ng/mL with a limit of detection less than 1 ng/mL.
Collapse
Affiliation(s)
- Nan Du
- Rice Quantum Institute, Rice University, Houston, TX 77005, USA
| | | | | | | | | | | |
Collapse
|