1
|
Warren CG, Dasgupta PK. Liquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review. Anal Chim Acta 2024; 1305:342507. [PMID: 38677834 DOI: 10.1016/j.aca.2024.342507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/29/2024]
Abstract
Microfluidic and capillary devices are increasingly being used in analytical applications while their overall size keeps decreasing. Detection sensitivity for these microdevices gains more importance as device sizes and consequently, sample volumes, decrease. This paper reviews optical, electrochemical, electrical, and mass spectrometric detection methods that are applicable to capillary scale and microfluidic devices, with brief introduction to the principles in each case. Much of this is considered in the context of separations. We do consider theoretical aspects of separations by open tubular liquid chromatography, arguably the most potentially fertile area of separations that has been left fallow largely because of lack of scale-appropriate detection methods. We also examine the theoretical basis of zone electrophoretic separations. Optical detection methods discussed include UV/Vis absorbance, fluorescence, chemiluminescence and refractometry. Amperometry is essentially the only electrochemical detection method used in microsystems. Suppressed conductance and especially contactless conductivity (admittance) detection are in wide use for the detection of ionic analytes. Microfluidic devices, integrated to various mass spectrometers, including ESI-MS, APCI-MS, and MALDI-MS are discussed. We consider the advantages and disadvantages of each detection method and compare the best reported limits of detection in as uniform a format as the available information allows. While this review pays more attention to recent developments, our primary focus has been on the novelty and ingenuity of the approach, regardless of when it was first proposed, as long as it can be potentially relevant to miniature platforms.
Collapse
Affiliation(s)
- Cable G Warren
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States
| | - Purnendu K Dasgupta
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States.
| |
Collapse
|
2
|
Guo Z, Zhao Y, Jin Z, Chang Y, Wang X, Guo G, Zhao Y. Monolithic 3D nanoelectrospray emitters based on a continuous fluid-assisted etching strategy for glass droplet microfluidic chip-mass spectrometry. Chem Sci 2024; 15:7781-7788. [PMID: 38784731 PMCID: PMC11110156 DOI: 10.1039/d4sc01700e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 04/23/2024] [Indexed: 05/25/2024] Open
Abstract
Glass microfluidic chips are suitable for coupling with mass spectrometry (MS) due to their flexible design, optical transparency and resistance to organic reagents. However, due to the high hardness and brittleness of glass, there is a lack of simple and feasible technology to manufacture a monolithic nanospray ionization (nESI) emitter on a glass microchip, which hinders its coupling with mass spectrometry. Here, a continuous fluid-assisted etching strategy is proposed to fabricate monolithic three-dimensional (3D) nESI emitters integrated into glass microchips. A continuous fluid of methanol is adopted to protect the inner wall of the channels and the bonding interface of the glass microfluidic chip from being wet-etched, forming sharp 3D nESI emitters. The fabricated 3D nESI emitter can form a stable electrospray plume, resulting in consistent nESI detection of acetylcholine with an RSD of 4.5% within 10 min. The fabricated 3D emitter is integrated on a glass microfluidic chip designed with a T-junction droplet generator, which can realize efficient analysis of acetylcholine in picoliter-volume droplets by nESI-MS. Stability testing of over 20 000 droplets detected by the established system resulted in an RSD of 9.1% over approximately 180 min. The detection of ten neurochemicals in rat cerebrospinal fluid droplets is achieved. The established glass droplet microfluidic chip-MS system exhibits potential for broad applications such as in vivo neurochemical monitoring and single-cell analysis in the future.
Collapse
Affiliation(s)
- Ziyang Guo
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Yingqi Zhao
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Zhao Jin
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Yaran Chang
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Xiayan Wang
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| | - Guangsheng Guo
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
- Minzu University of China Beijing 100081 China
| | - Yaoyao Zhao
- Department of Chemistry, Beijing University of Technology Beijing 100124 China
| |
Collapse
|
3
|
Schmidt AJ, Zamuruyev KO, LeVasseur MK, Fung S, Anishchenko IM, Kenyon NJ, Davis CE. Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries. MICROELECTRONIC ENGINEERING 2023; 276:111997. [PMID: 39301435 PMCID: PMC11412618 DOI: 10.1016/j.mee.2023.111997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. A custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10-40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6 mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r2≥0.95).
Collapse
Affiliation(s)
- Alexander J Schmidt
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Konstantin O Zamuruyev
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Michael K LeVasseur
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Stephanie Fung
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Ilya M Anishchenko
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Nicholas J Kenyon
- UC Davis Lung Center, Davis CA, USA
- VA Northern California Health Care System, Mather CA, USA
- Department of Internal Medicine, UC Davis, Sacramento CA, USA
| | - Cristina E Davis
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
- VA Northern California Health Care System, Mather CA, USA
| |
Collapse
|
4
|
Naghdi E, Moran GE, Reinau ME, De Malsche W, Neusüß C. Concepts and recent advances in microchip electrophoresis coupled to mass spectrometry: Technologies and applications. Electrophoresis 2023; 44:246-267. [PMID: 35977423 DOI: 10.1002/elps.202200179] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/11/2022] [Accepted: 08/13/2022] [Indexed: 02/01/2023]
Abstract
The online coupling of microchip electrophoresis (ME) as a fast, highly efficient, and low-cost miniaturized separation technique to mass spectrometry (MS) as an information-rich and sensitive characterization technique results in ME-MS an attractive tool for various applications. In this paper, we review the basic concepts and latest advances in technology for ME coupled to MS during the period of 2016-2021, covering microchip materials, structures, fabrication techniques, and interfacing to electrospray ionization (ESI)-MS and matrix-assisted laser desorption/ionization-MS. Two critical issues in coupling ME and ESI-MS include the electrical connection used to define the electrophoretic field strength along the separation channel and the generation of the electrospray for MS detection, as well as, a miniaturized ESI-tip. The recent commercialization of ME-MS in zone electrophoresis and isoelectric focusing modes has led to the widespread application of these techniques in academia and industry. Here we summarize recent applications of ME-MS for the separation and detection of antibodies, proteins, peptides, carbohydrates, metabolites, and so on. Throughout the paper these applications are discussed in the context of benefits and limitations of ME-MS in comparison to alternative techniques.
Collapse
Affiliation(s)
- Elahe Naghdi
- Department of Chemistry, Aalen University, Aalen, Germany
| | - Griffin E Moran
- Novo Nordisk A/S, Global Research Technologies, Maaloev, Denmark
| | | | - Wim De Malsche
- µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | | |
Collapse
|
5
|
Non-aqueous electrophoresis integrated with electrospray ionization mass spectrometry on a thiol-ene polymer-based microchip device. Anal Bioanal Chem 2021; 413:4195-4205. [PMID: 33954829 DOI: 10.1007/s00216-021-03374-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 04/20/2021] [Accepted: 04/23/2021] [Indexed: 10/21/2022]
Abstract
Non-aqueous capillary electrophoresis (NACE) on microfluidic chips is still a comparatively little explored area, despite the inherent advantages of this technique and its application potential for, in particular, lipophilic compounds. A main reason is probably the fact that implementation of NACE on microchips largely precluded the use of polymeric substrate materials. Here, we report non-aqueous electrophoresis on a thiol-ene-based microfluidic chip coupled to mass spectrometry via an on-chip ESI interface. Microchips with an integrated ESI emitter were fabricated using a double-molding approach. The durability of thiol-ene, when exposed to different organic solvents, was investigated with respect to swelling and decomposition of the polymer. Thiol-ene exhibited good stability against organic solvents such as methanol, ethanol, N-methylformamide, and formamide, which allows for a wide range of background electrolyte compositions. The integrated ESI emitter provided a stable spray with RSD% of the ESI signal ≤8%. Separation efficiency of the developed microchip electrophoresis system in different non-aqueous buffer solutions was tested with a mixture of several drugs of abuse. Ethanol- and methanol-based buffers provided comparable high theoretical plate numbers (≈ 6.6 × 104-1.6 × 105 m-1) with ethanol exhibiting the best separation efficiency. Direct coupling of non-aqueous electrophoresis to mass spectrometry allowed for fast analysis of hydrophobic compounds in the range of 0.1-5 μg mL-1 and 0.2-10 μg mL-1 and very good sensitivities (LOD ≈ 0.06-0.28 μg mL-1; LOQ ≈ 0.20-0.90 μg mL-1). The novel combination of non-aqueous CE on a microfluidic thiol-ene device and ESI-MS provides a mass-producible and highly versatile system for the analysis of, in particular, lipophilic compounds in a wide range of organic solvents. This offers promising potential for future applications in forensic, clinical, and environmental analysis. Graphical abstract.
Collapse
|
6
|
Yazdian Kashani S, Afzalian A, Shirinichi F, Keshavarz Moraveji M. Microfluidics for core-shell drug carrier particles - a review. RSC Adv 2020; 11:229-249. [PMID: 35423057 PMCID: PMC8691093 DOI: 10.1039/d0ra08607j] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 12/07/2020] [Indexed: 01/07/2023] Open
Abstract
Core-shell drug-carrier particles are known for their unique features. Due to the combination of superior properties not exhibited by the individual components, core-shell particles have gained a lot of interest. The structures could integrate core and shell characteristics and properties. These particles were designed for controlled drug release in the desired location. Therefore, the side effects would be minimized. So, these particles' advantages have led to the introduction of new methods and ideas for their fabrication. In the past few years, the generation of drug carrier core-shell particles in microfluidic chips has attracted much attention. This method makes it possible to produce particles at nanometer and micrometer levels of the same shape and size; it usually costs less than other methods. The other advantages of using microfluidic techniques compared to conventional bulk methods are integration capability, reproducibility, and higher efficiency. These advantages have created a positive outlook on this approach. This review gives an overview of the various fluidic concepts that are used to generate microparticles or nanoparticles. Also, an overview of traditional and more recent microfluidic devices and their design and structure for the generation of core-shell particles is given. The unique benefits of the microfluidic technique for core-shell drug carrier particle generation are demonstrated.
Collapse
Affiliation(s)
- Sepideh Yazdian Kashani
- Department of Chemical Engineering, Amirkabir University of Technology (Tehran Polytechnic) 1591634311 Tehran Iran +98 21 64543182
| | - Amir Afzalian
- Department of Chemical Engineering, Amirkabir University of Technology (Tehran Polytechnic) 1591634311 Tehran Iran +98 21 64543182
| | - Farbod Shirinichi
- Department of Chemical Engineering, Amirkabir University of Technology (Tehran Polytechnic) 1591634311 Tehran Iran +98 21 64543182
| | - Mostafa Keshavarz Moraveji
- Department of Chemical Engineering, Amirkabir University of Technology (Tehran Polytechnic) 1591634311 Tehran Iran +98 21 64543182
| |
Collapse
|
7
|
Svejdal RR, Sticker D, Sønderby C, Kutter JP, Rand KD. Thiol-ene microfluidic chip for fast on-chip sample clean-up, separation and ESI mass spectrometry of peptides and proteins. Anal Chim Acta 2020; 1140:168-177. [DOI: 10.1016/j.aca.2020.09.062] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 09/25/2020] [Accepted: 09/28/2020] [Indexed: 01/13/2023]
|
8
|
Buyuktuncel E. Microchip Electrophoresis and Bioanalytical Applications. CURR PHARM ANAL 2019. [DOI: 10.2174/1573412914666180831100533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Microanalytical systems have aroused great interest because they can analyze extremely
small sample volumes, improve the rate and throughput of chemical and biochemical analysis in a way
that reduces costs. Microchip Electrophoresis (ME) represents an effective separation technique to perform
quick analytical separations of complex samples. It offers high resolution and significant peak
capacity. ME is used in many areas, including biology, chemistry, engineering, and medicine. It is established
the same working principles as Capillary Electrophoresis (CE). It is possible to perform electrophoresis
in a more direct and convenient way in a microchip. Since the electric field is the driving
force of the electrodes, there is no need for high pressure as in chromatography. The amount of the voltage
that is applied in some electrophoresis modes, e.g. Micelle Electrokinetic Chromatography (MEKC)
and Capillary Zone Electrophoresis (CZE), mainly determines separation efficiency. Therefore, it is
possible to apply a higher electric field along a considerably shorter separation channel, hence it is possible
to carry out ME much quicker.
Collapse
Affiliation(s)
- Ebru Buyuktuncel
- Faculty of Pharmacy, Department of Analytical Chemistry, Inonu University, 44280, Malatya, Turkey
| |
Collapse
|
9
|
Lazar IM. Achieving Stable Electrospray Ionization Mass Spectrometry Detection from Microfluidic Chips. Methods Mol Biol 2019; 1906:225-237. [PMID: 30488396 DOI: 10.1007/978-1-4939-8964-5_15] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The past two decades have witnessed remarkable advances in the development of microfluidic devices as bioanalytical platforms for the analysis of biological molecules. The implementation of mass spectrometry (MS) detection systems on these devices has become inevitable, and various chip-MS ionization interfaces have been developed. As electrospray ionization (ESI) is particularly relevant for the analysis of large biological molecules such as proteins or peptides, efforts have focused on advancing interfaces that meet the demands of nano-separation techniques that are typically used prior to MS detection. Achieving stable ESI conditions that enable sensitive MS detection is, however, not trivial, especially when the spray is generated from a microfabricated platform. This chapter is aimed at providing a step-by-step protocol for producing stable and efficient electrospray sample ionization from microfluidic chips that are used for capillary electrophoresis (CE) separations.
Collapse
Affiliation(s)
- Iulia M Lazar
- Biological Sciences, Virginia Tech, Blacksburg, VA, USA.
| |
Collapse
|
10
|
Ahn J, Ko J, Lee S, Yu J, Kim Y, Jeon NL. Microfluidics in nanoparticle drug delivery; From synthesis to pre-clinical screening. Adv Drug Deliv Rev 2018; 128:29-53. [PMID: 29626551 DOI: 10.1016/j.addr.2018.04.001] [Citation(s) in RCA: 106] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 03/15/2018] [Accepted: 04/02/2018] [Indexed: 01/03/2023]
Abstract
Microfluidic technologies employ nano and microscale fabrication techniques to develop highly controllable and reproducible fluidic microenvironments. Utilizing microfluidics, lead compounds can be produced with the controlled physicochemical properties, characterized in a high-throughput fashion, and evaluated in in vitro biomimetic models of human organs; organ-on-a-chip. As a step forward from conventional in vitro culture methods, microfluidics shows promise in effective preclinical testing of nanoparticle-based drug delivery. This review presents a curated selection of state-of-the-art microfluidic platforms focusing on the fabrication, characterization, and assessment of nanoparticles for drug delivery applications. We also discuss the current challenges and future prospects of nanoparticle drug delivery development using microfluidics.
Collapse
|
11
|
Tähkä SM, Bonabi A, Jokinen VP, Sikanen TM. Aqueous and non-aqueous microchip electrophoresis with on-chip electrospray ionization mass spectrometry on replica-molded thiol-ene microfluidic devices. J Chromatogr A 2017; 1496:150-156. [PMID: 28347516 DOI: 10.1016/j.chroma.2017.03.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 03/03/2017] [Accepted: 03/10/2017] [Indexed: 12/25/2022]
Abstract
This work describes aqueous and non-aqueous capillary electrophoresis on thiol-ene-based microfluidic separation devices that feature fully integrated and sharp electrospray ionization (ESI) emitters. The chip fabrication is based on simple and low-cost replica-molding of thiol-ene polymers under standard laboratory conditions. The mechanical rigidity and the stability of the materials against organic solvents, acids and bases could be tuned by adjusting the respective stoichiometric ratio of the thiol and allyl ("ene") monomers, which allowed us to carry out electrophoresis separation in both aqueous and non-aqueous (methanol- and ethanol-based) background electrolytes. The stability of the ESI signal was generally ≤10% RSD for all emitters. The respective migration time repeatabilities in aqueous and non-aqueous background electrolytes were below 3 and 14% RSD (n=4-6, with internal standard). The analytical performance of the developed thiol-ene microdevices was shown in mass spectrometry (MS) based analysis of peptides, proteins, and small molecules. The theoretical plate numbers were the highest (1.2-2.4×104m-1) in ethanol-based background electrolytes. The ionization efficiency also increased under non-aqueous conditions compared to aqueous background electrolytes. The results show that replica-molding of thiol-enes is a feasible approach for producing ESI microdevices that perform in a stable manner in both aqueous and non-aqueous electrophoresis.
Collapse
Affiliation(s)
- Sari M Tähkä
- Faculty of Pharmacy, Drug Research Programme, Viikinkaari 5E, FI-00014, University of Helsinki, Helsinki, Finland.
| | - Ashkan Bonabi
- Faculty of Pharmacy, Drug Research Programme, Viikinkaari 5E, FI-00014, University of Helsinki, Helsinki, Finland.
| | - Ville P Jokinen
- Department of Materials Science and Engineering, School of Chemical Technology, Aalto University, Tietotie 3, FI-00076 Aalto, Espoo, Finland.
| | - Tiina M Sikanen
- Faculty of Pharmacy, Drug Research Programme, Viikinkaari 5E, FI-00014, University of Helsinki, Helsinki, Finland.
| |
Collapse
|
12
|
Štěpánová S, Kašička V. Analysis of proteins and peptides by electromigration methods in microchips. J Sep Sci 2016; 40:228-250. [PMID: 27704694 DOI: 10.1002/jssc.201600962] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 09/14/2016] [Accepted: 09/14/2016] [Indexed: 11/07/2022]
Abstract
This review presents the developments and applications of microchip electromigration methods in the separation and analysis of peptides and proteins in the period 2011-mid-2016. The developments in sample preparation and preconcentration, microchannel material, and surface treatment are described. Separations by various microchip electromigration methods (zone electrophoresis in free and sieving media, affinity electrophoresis, isotachophoresis, isoelectric focusing, electrokinetic chromatography, and electrochromatography) are demonstrated. Advances in detection methods are reported and novel applications in the areas of proteomics and peptidomics, quality control of peptide and protein pharmaceuticals, analysis of proteins and peptides in biomatrices, and determination of physicochemical parameters are shown.
Collapse
Affiliation(s)
- Sille Štěpánová
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Prague, Czech Republic
| | - Václav Kašička
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Prague, Czech Republic
| |
Collapse
|
13
|
Wang G, Li K, Purcell FJ, Zhao D, Zhang W, He Z, Tan S, Tang Z, Wang H, Reichmanis E. Three-Dimensional Clustered Nanostructures for Microfluidic Surface-Enhanced Raman Detection. ACS APPLIED MATERIALS & INTERFACES 2016; 8:24974-24981. [PMID: 27585300 DOI: 10.1021/acsami.6b10542] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A materials fabrication concept based on a fluid-construction strategy to create three-dimensional (3D) ZnO@ZnS-Ag active nanostructures at arbitrary position within confined microchannels to form an integrated microfluidic surface-enhanced Raman spectroscopy (SERS) system is presented. The fluid-construction process allowed facile construction of the nanostructured substrates, which were shown to possess a substantial number of integrated hot spots that support SERS activity. Finite-difference time-domain (FDTD) analysis suggested that the 3D clustered geometry facilitated hot spot formation. High sensitivity and good recycle performance were demonstrated using 4-mercaptobenzoic acid (4-MBA) and a mixture of Rhodamine 6G (R6G) and 4-MBA as target organic pollutants to evaluate the SERS microfluidic device performance. The 3D clustered nanostructures were also effective in the detection of a representative nerve agent and biomolecule. The results of this investigation provide a materials and process approach to the fabrication of requisite nanostructures for the online detection of organic pollutants, devices for real-time observation of environmental hazards, and personal-health monitoring.
Collapse
Affiliation(s)
- Gang Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University , Shanghai 201602, People's Republic of China
- School of Chemical and Biomolecular Engineering, School of Chemistry and Biochemistry, School of Materials Science and Engineering, Georgia Institute of Technology , Atlanta, Georgia 30332, United States
| | - Kerui Li
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University , Shanghai 201602, People's Republic of China
| | | | - De Zhao
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University , Shanghai 201602, People's Republic of China
| | - Wei Zhang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University , Shanghai 201602, People's Republic of China
| | - Zhongyuan He
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University , Shanghai 201602, People's Republic of China
| | - Shuai Tan
- School of Chemical and Biomolecular Engineering, School of Chemistry and Biochemistry, School of Materials Science and Engineering, Georgia Institute of Technology , Atlanta, Georgia 30332, United States
| | - Zhenguan Tang
- School of Chemical and Biomolecular Engineering, School of Chemistry and Biochemistry, School of Materials Science and Engineering, Georgia Institute of Technology , Atlanta, Georgia 30332, United States
| | - Hongzhi Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University , Shanghai 201602, People's Republic of China
| | - Elsa Reichmanis
- School of Chemical and Biomolecular Engineering, School of Chemistry and Biochemistry, School of Materials Science and Engineering, Georgia Institute of Technology , Atlanta, Georgia 30332, United States
| |
Collapse
|
14
|
Merits of online electrochemistry liquid sample desorption electrospray ionization mass spectrometry (EC/LS DESI MS). Anal Bioanal Chem 2016; 408:2227-38. [DOI: 10.1007/s00216-015-9246-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 11/25/2015] [Accepted: 12/02/2015] [Indexed: 12/11/2022]
|
15
|
Lotter C, Heiland JJ, Thurmann S, Mauritz L, Belder D. HPLC-MS with Glass Chips Featuring Monolithically Integrated Electrospray Emitters of Different Geometries. Anal Chem 2016; 88:2856-63. [DOI: 10.1021/acs.analchem.5b04583] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Carsten Lotter
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Josef J. Heiland
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Sebastian Thurmann
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Laura Mauritz
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
16
|
Xiong B, Wang L, Wang Y, Bao Y, Jiang S, Ye M. Three-dimensional hydrodynamic focusing microfluidic emitter: a strategy to inhibit sample ion expansion in nanoelectrospray ionization. Analyst 2016; 141:177-82. [DOI: 10.1039/c5an01619c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
A proposed 3D HFNE was used to generate a wrapped electrospray to achieve the inhibition of sample ion expansion, thus restraining injection loss in electrospray ionization.
Collapse
Affiliation(s)
- Bo Xiong
- Key Laboratory of Pesticides & Chemical Biology
- Ministry of Education
- College of Chemistry
- Central China Normal University
- Wuhan 430079
| | - Lingling Wang
- Key Laboratory of Pesticides & Chemical Biology
- Ministry of Education
- College of Chemistry
- Central China Normal University
- Wuhan 430079
| | - Yujiao Wang
- Key Laboratory of Pesticides & Chemical Biology
- Ministry of Education
- College of Chemistry
- Central China Normal University
- Wuhan 430079
| | - Yajing Bao
- Key Laboratory of Pesticides & Chemical Biology
- Ministry of Education
- College of Chemistry
- Central China Normal University
- Wuhan 430079
| | - Shichang Jiang
- Key Laboratory of Pesticides & Chemical Biology
- Ministry of Education
- College of Chemistry
- Central China Normal University
- Wuhan 430079
| | - Mingyue Ye
- Key Laboratory of Pesticides & Chemical Biology
- Ministry of Education
- College of Chemistry
- Central China Normal University
- Wuhan 430079
| |
Collapse
|
17
|
Štěpánová S, Kašička V. Recent developments and applications of capillary and microchip electrophoresis in proteomic and peptidomic analyses. J Sep Sci 2015; 39:198-211. [DOI: 10.1002/jssc.201500973] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 10/06/2015] [Accepted: 10/06/2015] [Indexed: 12/19/2022]
Affiliation(s)
- Sille Štěpánová
- Institute of Organic Chemistry and Biochemistry; The Czech Academy of Sciences; Prague Czech Republic
| | - Václav Kašička
- Institute of Organic Chemistry and Biochemistry; The Czech Academy of Sciences; Prague Czech Republic
| |
Collapse
|
18
|
Interfacing microchip isoelectric focusing with on-chip electrospray ionization mass spectrometry. J Chromatogr A 2015; 1398:121-6. [DOI: 10.1016/j.chroma.2015.04.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 04/14/2015] [Accepted: 04/17/2015] [Indexed: 12/23/2022]
|
19
|
Klepárník K. Recent advances in combination of capillary electrophoresis with mass spectrometry: Methodology and theory. Electrophoresis 2014; 36:159-78. [DOI: 10.1002/elps.201400392] [Citation(s) in RCA: 84] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 09/11/2014] [Accepted: 09/11/2014] [Indexed: 12/15/2022]
Affiliation(s)
- Karel Klepárník
- Institute of Analytical Chemistry; Academy of Sciences of the Czech Republic; Brno Czech Republic
| |
Collapse
|
20
|
Wang X, Yi L, Mukhitov N, Schrell AM, Dhumpa R, Roper MG. Microfluidics-to-mass spectrometry: a review of coupling methods and applications. J Chromatogr A 2014; 1382:98-116. [PMID: 25458901 DOI: 10.1016/j.chroma.2014.10.039] [Citation(s) in RCA: 83] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 10/09/2014] [Accepted: 10/12/2014] [Indexed: 02/05/2023]
Abstract
Microfluidic devices offer great advantages in integrating sample processes, minimizing sample and reagent volumes, and increasing analysis speed, while mass spectrometry detection provides high information content, is sensitive, and can be used in quantitative analyses. The coupling of microfluidic devices to mass spectrometers is becoming more common with the strengths of both systems being combined to analyze precious and complex samples. This review summarizes select achievements published between 2010 and July 2014 in novel coupling between microfluidic devices and mass spectrometers. The review is subdivided by the types of ionization sources employed, and the different microfluidic systems used.
Collapse
Affiliation(s)
- Xue Wang
- Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL 32306, USA
| | - Lian Yi
- Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL 32306, USA
| | - Nikita Mukhitov
- Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL 32306, USA
| | - Adrian M Schrell
- Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL 32306, USA
| | - Raghuram Dhumpa
- Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL 32306, USA
| | - Michael G Roper
- Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, FL 32306, USA.
| |
Collapse
|
21
|
Lab-on-a-Chip hyphenation with mass spectrometry: strategies for bioanalytical applications. Curr Opin Biotechnol 2014; 31:79-85. [PMID: 25232996 DOI: 10.1016/j.copbio.2014.08.009] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Accepted: 08/28/2014] [Indexed: 11/23/2022]
Abstract
The Lab-on-a-Chip concept aims at miniaturizing laboratory processes to enable automation and/or parallelization via microfluidic chips that are capable of handling minute sample volumes. Mass spectrometry is nowadays the detection method of choice, because of its selectivity, sensitivity and wide application range. We review the most interesting examples over the last two-and-a-half years where the two techniques were used for bioanalytical applications. Furthermore, we discuss the merits and limitations of such hyphenated systems. We inventorize the reported applications and approaches. We see an ongoing trend towards chip-based liquid chromatography-mass spectrometry usage and small volume analysis applications, particularly in the field of proteomics where bottom-up approaches profit from chip-based technologies and hyphenation with complex cell cultures.
Collapse
|
22
|
Lin SL, Lin TY, Fuh MR. Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications: An update. Electrophoresis 2013; 35:1275-84. [DOI: 10.1002/elps.201300415] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Revised: 10/07/2013] [Accepted: 10/08/2013] [Indexed: 12/22/2022]
Affiliation(s)
- Shu-Ling Lin
- Department of Chemistry; Soochow University; Taipei Taiwan
| | | | - Ming-Ren Fuh
- Department of Chemistry; Soochow University; Taipei Taiwan
| |
Collapse
|
23
|
Recent developments in microfluidic chip-based separation devices coupled to MS for bioanalysis. Bioanalysis 2013; 5:2567-80. [DOI: 10.4155/bio.13.196] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
In recent years, the development of microfluidic chip separation devices coupled to MS has dramatically increased for high-throughput bioanalysis. In this review, advances in different types of microfluidic chip separation devices, such as electrophoresis- and LC-based microchips, as well as 2D design of microfluidic chip-based separation devices will be discussed. In addition, the utilization of chip-based separation devices coupled to MS for analyzing peptides/proteins, glycans, drug metabolites and biomarkers for various bioanalytical applications will be evaluated.
Collapse
|