1
|
Nan L, Zhang H, Weitz DA, Shum HC. Development and future of droplet microfluidics. LAB ON A CHIP 2024; 24:1135-1153. [PMID: 38165829 DOI: 10.1039/d3lc00729d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Over the past two decades, advances in droplet-based microfluidics have facilitated new approaches to process and analyze samples with unprecedented levels of precision and throughput. A wide variety of applications has been inspired across multiple disciplines ranging from materials science to biology. Understanding the dynamics of droplets enables optimization of microfluidic operations and design of new techniques tailored to emerging demands. In this review, we discuss the underlying physics behind high-throughput generation and manipulation of droplets. We also summarize the applications in droplet-derived materials and droplet-based lab-on-a-chip biotechnology. In addition, we offer perspectives on future directions to realize wider use of droplet microfluidics in industrial production and biomedical analyses.
Collapse
Affiliation(s)
- Lang Nan
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong, China
| | - Huidan Zhang
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - David A Weitz
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong, China
| | - Ho Cheung Shum
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Shatin, New Territories, Hong Kong, China
| |
Collapse
|
2
|
Liu X, Zhou X, Li X, Wei Y, Wang T, Liu S, Yang H, Sun X. Saliva Analysis Based on Microfluidics: Focusing the Wide Spectrum of Target Analyte. Crit Rev Anal Chem 2023:1-23. [PMID: 38039145 DOI: 10.1080/10408347.2023.2287656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
Saliva is one of the most critical human body fluids that can reflect the state of the human body. The detection of saliva is of great significance for disease diagnosis and health monitoring. Microfluidics, characterized by microscale size and high integration, is an ideal platform for the development of rapid and low-cost disease diagnostic techniques and devices. Microfluidic-based saliva testing methods have aroused considerable interest due to the increasing need for noninvasive testing and frequent or long-term testing. This review briefly described the significance of saliva analysis and generally classified the targets in saliva detection into pathogenic microorganisms, inorganic substances, and organic substances. By using this classification as a benchmark, the state-of-the-art research results on microfluidic detection of various substances in saliva were summarized. This work also put forward the challenges and future development directions of microfluidic detection methods for saliva.
Collapse
Affiliation(s)
- Xin Liu
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, Shenyang, China
| | - Xinyue Zhou
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, Shenyang, China
| | - Xiaojia Li
- Teaching Center for Basic Medical Experiment, China Medical University, Shenyang, China
| | - Yixuan Wei
- Teaching Center for Basic Medical Experiment, China Medical University, Shenyang, China
| | - Tianlin Wang
- School of Intelligent Medicine, China Medical University, Shenyang, China
| | - Shuo Liu
- Department of Respiratory Medicine, The Fourth Hospital of China Medical University, Shenyang, China
| | - Huazhe Yang
- School of Intelligent Medicine, China Medical University, Shenyang, China
| | - Xiaoting Sun
- School of Forensic Medicine, China Medical University, Shenyang, China
| |
Collapse
|
3
|
Pal A, Kaswan K, Barman SR, Lin YZ, Chung JH, Sharma MK, Liu KL, Chen BH, Wu CC, Lee S, Choi D, Lin ZH. Microfluidic nanodevices for drug sensing and screening applications. Biosens Bioelectron 2023; 219:114783. [PMID: 36257116 PMCID: PMC9533638 DOI: 10.1016/j.bios.2022.114783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Revised: 09/18/2022] [Accepted: 10/01/2022] [Indexed: 11/03/2022]
Abstract
The outbreak of pandemics (e.g., severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 in 2019), influenza A viruses (H1N1 in 2009), etc.), and worldwide spike in the aging population have created unprecedented urgency for developing new drugs to improve disease treatment. As a result, extensive efforts have been made to design novel techniques for efficient drug monitoring and screening, which form the backbone of drug development. Compared to traditional techniques, microfluidics-based platforms have emerged as promising alternatives for high-throughput drug screening due to their inherent miniaturization characteristics, low sample consumption, integration, and compatibility with diverse analytical strategies. Moreover, the microfluidic-based models utilizing human cells to produce in-vitro biomimetics of the human body pave new ways to predict more accurate drug effects in humans. This review provides a comprehensive summary of different microfluidics-based drug sensing and screening strategies and briefly discusses their advantages. Most importantly, an in-depth outlook of the commonly used detection techniques integrated with microfluidic chips for highly sensitive drug screening is provided. Then, the influence of critical parameters such as sensing materials and microfluidic platform geometries on screening performance is summarized. This review also outlines the recent applications of microfluidic approaches for screening therapeutic and illicit drugs. Moreover, the current challenges and the future perspective of this research field is elaborately highlighted, which we believe will contribute immensely towards significant achievements in all aspects of drug development.
Collapse
Affiliation(s)
- Arnab Pal
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; International Intercollegiate PhD Program, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Kuldeep Kaswan
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; International Intercollegiate PhD Program, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Snigdha Roy Barman
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; International Intercollegiate PhD Program, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Yu-Zih Lin
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Jun-Hsuan Chung
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Manish Kumar Sharma
- Department of Materials Science and Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Kuei-Lin Liu
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan
| | - Bo-Huan Chen
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; International Intercollegiate PhD Program, National Tsing Hua University, Hsinchu, 30013, Taiwan; Department of Gastroenterology and Hepatology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, 333, Taiwan
| | - Chih-Cheng Wu
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; Center of Quality Management, National Taiwan University Hospital, Hsinchu Branch, Hsinchu, 30059, Taiwan; College of Medicine, National Taiwan University, Taipei, 10051, Taiwan; Institute of Cellular and System Medicine, National Health Research Institute, Zhunan, 35053, Taiwan
| | - Sangmin Lee
- School of Mechanical Engineering, Chung-Ang University, Seoul, 06974, South Korea.
| | - Dongwhi Choi
- Department of Mechanical Engineering (Integrated Engineering Program), Kyung Hee University, Gyeonggi, 17104, South Korea.
| | - Zong-Hong Lin
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; International Intercollegiate PhD Program, National Tsing Hua University, Hsinchu, 30013, Taiwan; Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, 30013, Taiwan; Department of Chemistry, National Tsing Hua University, Hsinchu, 30013, Taiwan; Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu, 30013, Taiwan; Department of Mechanical Engineering (Integrated Engineering Program), Kyung Hee University, Gyeonggi, 17104, South Korea.
| |
Collapse
|
4
|
Shen P, Jia Y, Shi S, Sun J, Han X. Analytical and biomedical applications of microfluidics in traditional Chinese medicine research. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
5
|
Kanjwal MA, Ghaferi AA. Advanced Waveguide Based LOC Biosensors: A Minireview. SENSORS (BASEL, SWITZERLAND) 2022; 22:5443. [PMID: 35891123 PMCID: PMC9323137 DOI: 10.3390/s22145443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/28/2022] [Accepted: 07/13/2022] [Indexed: 06/15/2023]
Abstract
This mini review features contemporary advances in mid-infrared (MIR) thin-film waveguide technology and on-chip photonics, promoting high-performance biosensing platforms. Supported by recent developments in MIR thin-film waveguides, it is expected that label-free assimilated MIR sensing platforms will soon supplement the current sensing technologies for biomedical diagnostics. The state-of-the-art shows that various types of waveguide material can be utilized for waveguide spectroscopic measurements in MIR. However, there are challenges to integrating these waveguide platforms with microfluidic/Lab-on-a-Chip (LOC) devices, due to poor light-material interactions. Graphene and its analogs have found many applications in microfluidic-based LOC devices, to address to this issue. Graphene-based materials possess a high conductivity, a large surface-to-volume ratio, a smaller and tunable bandgap, and allow easier sample loading; which is essential for acquiring precise electrochemical information. This work discusses advanced waveguide materials, their advantages, and disease diagnostics with MIR thin-film based waveguides. The incorporation of graphene into waveguides improves the light-graphene interaction, and photonic devices greatly benefit from graphene's strong field-controlled optical response.
Collapse
|
6
|
Aitekenov S, Sultangaziyev A, Abdirova P, Yussupova L, Gaipov A, Utegulov Z, Bukasov R. Raman, Infrared and Brillouin Spectroscopies of Biofluids for Medical Diagnostics and for Detection of Biomarkers. Crit Rev Anal Chem 2022; 53:1561-1590. [PMID: 35157535 DOI: 10.1080/10408347.2022.2036941] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
This review surveys Infrared, Raman/SERS and Brillouin spectroscopies for medical diagnostics and detection of biomarkers in biofluids, that include urine, blood, saliva and other biofluids. These optical sensing techniques are non-contact, noninvasive and relatively rapid, accurate, label-free and affordable. However, those techniques still have to overcome some challenges to be widely adopted in routine clinical diagnostics. This review summarizes and provides insights on recent advancements in research within the field of vibrational spectroscopy for medical diagnostics and its use in detection of many health conditions such as kidney injury, cancers, cardiovascular and infectious diseases. The six comprehensive tables in the review and four tables in supplementary information summarize a few dozen experimental papers in terms of such analytical parameters as limit of detection, range, diagnostic sensitivity and specificity, and other figures of merits. Critical comparison between SERS and FTIR methods of analysis reveals that on average the reported sensitivity for biomarkers in biofluids for SERS vs FTIR is about 103 to 105 times higher, since LOD SERS are lower than LOD FTIR by about this factor. High sensitivity gives SERS an edge in detection of many biomarkers present in biofluids at low concentration (nM and sub nM), which can be particularly advantageous for example in early diagnostics of cancer or viral infections.HighlightsRaman, Infrared spectroscopies use low volume of biofluidic samples, little sample preparation, fast time of analysis and relatively inexpensive instrumentation.Applications of SERS may be a bit more complicated than applications of FTIR (e.g., limited shelf life for nanoparticles and substrates, etc.), but this can be generously compensated by much higher (by several order of magnitude) sensitivity in comparison to FTIR.High sensitivity makes SERS a noninvasive analytical method of choice for detection, quantification and diagnostics of many health conditions, metabolites, and drugs, particularly in diagnostics of cancer, including diagnostics of its early stages.FTIR, particularly ATR-FTIR can be a method of choice for efficient sensing of many biomarkers, present in urine, blood and other biofluids at sufficiently high concentrations (mM and even a few µM)Brillouin scattering spectroscopy detecting visco-elastic properties of probed liquid medium, may also find application in clinical analysis of some biofluids, such as cerebrospinal fluid and urine.
Collapse
Affiliation(s)
- Sultan Aitekenov
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Alisher Sultangaziyev
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Perizat Abdirova
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Lyailya Yussupova
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | | | - Zhandos Utegulov
- Department of Physics, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| | - Rostislav Bukasov
- Department of Chemistry, School of Sciences and Humanities (SSH), Nazarbayev University, Nur-Sultan, Kazakhstan
| |
Collapse
|
7
|
Wang L, Zou Y, Sun H, Jon CS, Nardiello D, Quinto M, Shang HB, Li D. Ex-situ and in-situ rapid and quantitative determination of benzene derivatives in seawater using nanoconfined liquid phase nanoextraction. Talanta 2021; 235:122781. [PMID: 34517639 DOI: 10.1016/j.talanta.2021.122781] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 07/29/2021] [Accepted: 08/02/2021] [Indexed: 11/18/2022]
Abstract
Benzene derivatives (BDs) constitute a class of environmental pollutants whose exposure poses a grave risk to human health. These compounds rapidly diffuse from the atmosphere to the marine ecosystem: for this reason, their monitoring in seawater is every day more compelling. In this work, nanoconfined liquid phase nanoextraction (NLPNE), a versatile extraction technique recently described, has been for the first time applied to the gas chromatographic mass spectrometry (GC/MS) analysis of BDs in seawater. Ex-situ and in-situ NLPNE procedures have been developed and optimized in terms of extraction capabilities, analysis time, precision, and accuracy. Compared to the traditional extraction procedures, based on solid-phase microextraction (SPME) and liquid-liquid extraction (LLE), the proposed NLPNE methods allowed a rapid on-site analysis of benzene compounds with low solvent consumption, higher enrichment factors, and improved automation grade. Determination coefficients ranging from 0.9929 to 0.9997 were obtained for all BDs in the range 0.10-500 ng mL-1 and 5.00-500 ng mL-1, for ex-situ and in-situ NLPNE, respectively. Ex-situ and in-situ limits of detection ranged from 0.2 to 7.6 ng mL-1 and 0.04-1.00 ng mL-1. Our results suggest that NLPNE coupled to GC-MS can be considered a powerful technique for high-throughput analyses of trace compounds in environmental, food and biological samples.
Collapse
Affiliation(s)
- Liyuan Wang
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China
| | - Yilin Zou
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China
| | - Huaze Sun
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China
| | - Chol-San Jon
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China
| | - Donatella Nardiello
- DAFNE - Department of Agriculture, Food, Natural Resources and Engineering, University of Foggia, Via Napoli 25, I-71122, Foggia, Italy
| | - Maurizio Quinto
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China; DAFNE - Department of Agriculture, Food, Natural Resources and Engineering, University of Foggia, Via Napoli 25, I-71122, Foggia, Italy
| | - Hai-Bo Shang
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China.
| | - Donghao Li
- Department of Chemistry, Yanbian University, Park Road 977, Yanji, 133002, Jilin Province, PR China.
| |
Collapse
|
8
|
Alidoust M, Baharfar M, Manouchehri M, Yamini Y, Tajik M, Seidi S. Emergence of microfluidic devices in sample extraction; an overview of diverse methodologies, principals, and recent advancements. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116352] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
9
|
Benéitez NT, Baumgartner B, Missinne J, Radosavljevic S, Wacht D, Hugger S, Leszcz P, Lendl B, Roelkens G. Mid-IR sensing platform for trace analysis in aqueous solutions based on a germanium-on-silicon waveguide chip with a mesoporous silica coating for analyte enrichment. OPTICS EXPRESS 2020; 28:27013-27027. [PMID: 32906963 DOI: 10.1364/oe.399646] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 07/25/2020] [Indexed: 06/11/2023]
Abstract
A novel platform based on evanescent wave sensing in the 6.5 to 7.5 µm wavelength range is presented with the example of toluene detection in an aqueous solution. The overall sensing platform consists of a germanium-on-silicon waveguide with a functionalized mesoporous silica cladding and integrated microlenses for alignment-tolerant back-side optical interfacing with a tunable laser spectrometer. Hydrophobic functionalization of the mesoporous cladding allows enrichment of apolar analyte molecules and prevents strong interaction of water with the evanescent wave. The sensing performance was evaluated for aqueous toluene standards resulting in a limit of detection of 7 ppm. Recorded adsorption/desorption profiles followed Freundlich adsorption isotherms with rapid equilibration and resulting sensor response times of a few seconds. This indicates that continuous monitoring of contaminants in water is possible. A significant increase in LOD can be expected by likely improvements to the spectrometer noise floor which, expressed as a relative standard deviation of 100% lines, is currently in the range of 10-2A.U.
Collapse
|
10
|
Mittal V, Mashanovich GZ, Wilkinson JS. Perspective on Thin Film Waveguides for on-Chip Mid-Infrared Spectroscopy of Liquid Biochemical Analytes. Anal Chem 2020; 92:10891-10901. [PMID: 32658466 DOI: 10.1021/acs.analchem.0c01296] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Miniaturized spectrometers offering low cost, low reagent consumption, high throughput, sensitivity and automation are the future of sensing and have significant applications in environmental monitoring, food safety, biotechnology, pharmaceuticals, and healthcare. Midinfrared (MIR) spectroscopy employing complementary metal oxide semiconductor (CMOS) compatible thin film waveguides and microfluidics shows great promise toward highly integrated and robust detection tools and liquid handling. This perspective provides an overview of the emergence of thin film optical waveguides used for evanescent field sensing of liquid chemical and biological samples for MIR absorption spectroscopy. The state of the art of new material and waveguide systems used for spectroscopic measurements in the MIR is presented. An outlook on the advantages and future of waveguide-based MIR spectroscopy for application in clinical settings for point-of-care biochemical analysis is discussed.
Collapse
Affiliation(s)
- Vinita Mittal
- Zepler Institute for Photonics and Nanoelectronics, University of Southampton, Southampton, SO17 1BJ, United Kingdom
| | - Goran Z Mashanovich
- Zepler Institute for Photonics and Nanoelectronics, University of Southampton, Southampton, SO17 1BJ, United Kingdom.,School of Electrical Engineering, University of Belgrade, 11120 Belgrade, Serbia
| | - James S Wilkinson
- Zepler Institute for Photonics and Nanoelectronics, University of Southampton, Southampton, SO17 1BJ, United Kingdom
| |
Collapse
|
11
|
Lan W, Liu D, Guo X, Liu A, Sun Q, Li X, Jing S, Li S. Study on Liquid–Liquid Droplet Flow Separation in a T-Shaped Microseparator. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c01379] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Wenjie Lan
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China
| | - Dan Liu
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China
| | - Xuqiang Guo
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China
| | - Aixian Liu
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China
| | - Qiang Sun
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China
| | - Xingxun Li
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China
| | - Shan Jing
- Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China
| | - Shaowei Li
- Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China
- State Key Laboratory of Chemical Engineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|
12
|
Lozeman JJA, Führer P, Olthuis W, Odijk M. Spectroelectrochemistry, the future of visualizing electrode processes by hyphenating electrochemistry with spectroscopic techniques. Analyst 2020; 145:2482-2509. [DOI: 10.1039/c9an02105a] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Reviewing the future of electrochemistry combined with infrared, Raman, and nuclear magnetic resonance spectroscopy as well as mass spectrometry.
Collapse
Affiliation(s)
- Jasper J. A. Lozeman
- BIOS Lab-on-a-Chip Group
- MESA+ Institute
- University of Twente
- 7522 NB Enschede
- The Netherlands
| | - Pascal Führer
- BIOS Lab-on-a-Chip Group
- MESA+ Institute
- University of Twente
- 7522 NB Enschede
- The Netherlands
| | - Wouter Olthuis
- BIOS Lab-on-a-Chip Group
- MESA+ Institute
- University of Twente
- 7522 NB Enschede
- The Netherlands
| | - Mathieu Odijk
- BIOS Lab-on-a-Chip Group
- MESA+ Institute
- University of Twente
- 7522 NB Enschede
- The Netherlands
| |
Collapse
|
13
|
Zhou Y, Huang J, Chen Z, Wang Y, Xu J. Controlled retention of droplets and the enhancement of mass transfer in microchannel with multi-groove structure. Chem Eng Sci 2019. [DOI: 10.1016/j.ces.2019.115223] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
14
|
Celikbas E, Balaban S, Evran S, Coskunol H, Timur S. A Bottom-Up Approach for Developing Aptasensors for Abused Drugs: Biosensors in Forensics. BIOSENSORS-BASEL 2019; 9:bios9040118. [PMID: 31581533 PMCID: PMC6955935 DOI: 10.3390/bios9040118] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 09/27/2019] [Accepted: 09/30/2019] [Indexed: 02/07/2023]
Abstract
Aptamer-based point-of-care (POC) diagnostics platforms may be of substantial benefit in forensic analysis as they provide rapid, sensitive, user-friendly, and selective analysis tools for detection. Aptasensors have not yet been adapted commercially. However, the significance of the applications of aptasensors in the literature exceeded their potential. Herein, in this review, a bottom-up approach is followed to describe the aptasensor development and application procedure, starting from the synthesis of the corresponding aptamer sequence for the selected analyte to creating a smart surface for the sensitive detection of the molecule of interest. Optical and electrochemical biosensing platforms, which are designed with aptamers as recognition molecules, detecting abused drugs are critically reviewed, and existing and possible applications of different designs are discussed. Several potential disciplines in which aptamer-based biosensing technology can be of greatest value, including forensic drug analysis and biological evidence, are then highlighted to encourage researchers to focus on developing aptasensors in these specific areas.
Collapse
Affiliation(s)
- Eda Celikbas
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
- Correspondence: (E.A.); (S.E.); (S.T.)
| | - Simge Balaban
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
| | - Serap Evran
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
- Department of Biochemistry, Faculty of Science, Ege University, 35100 Bornova, Izmir, Turkey
- Correspondence: (E.A.); (S.E.); (S.T.)
| | - Hakan Coskunol
- Department of Mental Health and Diseases, Faculty of Medicine, Ege University, 35100 Bornova, Izmir, Turkey;
| | - Suna Timur
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
- Department of Biochemistry, Faculty of Science, Ege University, 35100 Bornova, Izmir, Turkey
- Central Research Testing and Analysis Laboratory Research and Application Center, Ege University, 35100 Bornova, Izmir, Turkey
- Correspondence: (E.A.); (S.E.); (S.T.)
| |
Collapse
|
15
|
Isensee K, Kröger-Lui N, Petrich W. Biomedical applications of mid-infrared quantum cascade lasers - a review. Analyst 2019; 143:5888-5911. [PMID: 30444222 DOI: 10.1039/c8an01306c] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Mid-infrared spectroscopy has been applied to research in biology and medicine for more than 20 years and conceivable applications have been identified. More recently, these applications have been shown to benefit from the use of quantum cascade lasers due to their specific properties, namely high spectral power density, small beam parameter product, narrow emission spectrum and, if needed, tuning capabilities. This review provides an overview of the achievements and illustrates some applications which benefit from the key characteristics of quantum cascade laser-based mid-infrared spectroscopy using examples such as breath analysis, the investigation of serum, non-invasive glucose monitoring in bulk tissue and the combination of spectroscopy and microscopy of tissue thin sections for rapid histopathology.
Collapse
Affiliation(s)
- Katharina Isensee
- Kirchhoff-Institute for Physics, Heidelberg University, INF 277, 69120 Heidelberg, Germany.
| | | | | |
Collapse
|
16
|
A porous organic polymer with magnetic nanoparticles on a chip array for preconcentration of platinum(IV), gold(III) and bismuth(III) prior to their on-line quantitation by ICP-MS. Mikrochim Acta 2019; 186:107. [PMID: 30637494 DOI: 10.1007/s00604-018-3139-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 12/01/2018] [Indexed: 10/27/2022]
Abstract
A chip-based array is described for magnetic solid-phase microextraction (MSPME) of the ions of Pt, Au and Bi. Magnetic porous organic polymers (MOPs) prepared from magnetite nanoparticles and 1,3,5-tris(4-aminophenyl)benzene are introduced as a novel adsorbent. Eight solid phase extraction columns packed with MOPs were integrated in parallel on a microfluidic chip for array microextraction. After elution with a 12% (m/v) solution of cysteamine hydrochloride (pH 8.0), the eluent is introduced into an ICP-MS instrument for quantification. Under the optimized conditions, the limits of detection for Pt, Au and Bi are 8.6, 4.4 and 3.4 ng L-1, respectively. The sample throughput is 7 h-1, and the adsorption capacities are 32, 24 and 24 μg mg-1 for Pt, Au and Bi, respectively. The method was validated by the determination of Bi in a certified reference material (GSH-1A; human hair), and the values obtained coincided with the certified value. This method was also applied to the determination of Pt, Au and Bi in (spiked) urine and cell samples, and good recoveries (85.8-113%) were achieved. The method is highly sensitive and has a high throughput and a low sample/reagent consumption (with 500 HeLa cells consumed). Graphical abstract Schematic presentation of the magnetic packed column, microfluidic chip, and online chip-based MSPME-ICPMS system. Design sketch of the online system: microextraction unit (blue lines), microvalves (black lines), outlet channels (yellow lines), permanent magnets (red), urine and cell samples.
Collapse
|
17
|
de Araujo WR, Cardoso TM, da Rocha RG, Santana MH, Muñoz RA, Richter EM, Paixão TR, Coltro WK. Portable analytical platforms for forensic chemistry: A review. Anal Chim Acta 2018; 1034:1-21. [DOI: 10.1016/j.aca.2018.06.014] [Citation(s) in RCA: 123] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 05/18/2018] [Accepted: 06/07/2018] [Indexed: 01/28/2023]
|
18
|
Mao S, Zhang Y, Zhang Q, Lin JM, Uchiyama K. Local surface modification at precise position using a chemical pen. Talanta 2018; 187:246-251. [PMID: 29853042 DOI: 10.1016/j.talanta.2018.05.044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 05/10/2018] [Accepted: 05/11/2018] [Indexed: 11/17/2022]
Abstract
Push-pull cannula system, which was first proposed by Gaddum, has grown to be an important method for the perfusion of brain and region-selective surface treatment. However, reported push-pull cannula systems only concerned on single reagent applications. Microfluidic system was then an exciting tool for multi-reagent treatment on substrate in closed microchannels. Nowadays, it is still a challenge to apply online mixing and reaction for surface pattern in an open environment. Here, we present a novel method using a chemical pen that enables region-selective online chemical reactions for the micro-surface modification/patterning. We utilized this method to fabricate labeling protein array using an online labeling strategy. Moreover, the device was applied for local modification of biomaterials surface by using a three-component reaction at precise position. This tool was the first demonstration of design to perform online reaction of two different reagents on a real solid sample in an open environment. It was demonstrated a useful method for protein array fabrication with online labeled protein.
Collapse
Affiliation(s)
- Sifeng Mao
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, Beijing 100084, China
| | - Yong Zhang
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji 192-0362, Tokyo
| | - Qiang Zhang
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, Beijing 100084, China
| | - Jin-Ming Lin
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, Beijing 100084, China.
| | - Katsumi Uchiyama
- Department of Applied Chemistry, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, Minamiohsawa, Hachioji 192-0362, Tokyo.
| |
Collapse
|
19
|
Yu X, Chen B, He M, Wang H, Tian S, Hu B. Facile Design of Phase Separation for Microfluidic Droplet-Based Liquid Phase Microextraction as a Front End to Electrothermal Vaporization-ICPMS for the Analysis of Trace Metals in Cells. Anal Chem 2018; 90:10078-10086. [PMID: 30039697 DOI: 10.1021/acs.analchem.8b03078] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The issue of quantifying trace metals in cells has drawn widespread attention but is threatened with insufficient sensitivity of the instruments, complex cellular matrix and limited cell consumption. In this study, microfluidic droplet-based liquid phase microextraction (LPME), as a miniaturized platform, was developed and combined with electrothermal vaporization (ETV)-inductively coupled plasma mass spectrometry (ICPMS) for the analysis of trace Cd, Hg, Pb, and Bi in cells. A novel and facile design of phase separation region was proposed, which made the phase separation very easily for subsequent ETV-ICPMS detection. Mechanism of the phase separation was carefully discussed using the incompressible formulation of the Navier-Stokes equations. The developed microfluidic droplet-based LPME system exhibited much higher extraction efficiency to target metals than microfluidic stratified flow-based LPME. Under the optimized conditions, the limits of detection of the proposed microfluidic droplet-based LPME-ETV-ICPMS system were 2.5, 3.9, 5.5, and 3.4 ng L-1 for Cd, Hg, Pb, and Bi, respectively. The accuracy of the developed method was well validated by analyzing the target metals in Certified Reference Materials of GBW07601a human hair. Finally, the proposed method was successfully applied to the analysis of target metals in HeLa and HepG2 cells with the recoveries for the spiked samples ranging from 83.5 to 112.3%. Overall, the proposed design is a simple and reliable solution for the phase separation on droplet-chip and the microfluidic droplet-based LPME-ETV-ICPMS combination strategy shows great promise for trace elements analysis in cells.
Collapse
Affiliation(s)
- Xiaoxiao Yu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry , Wuhan University , Wuhan 430072 , China
| | - Beibei Chen
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry , Wuhan University , Wuhan 430072 , China
| | - Man He
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry , Wuhan University , Wuhan 430072 , China
| | - Han Wang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry , Wuhan University , Wuhan 430072 , China
| | - Songbai Tian
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry , Wuhan University , Wuhan 430072 , China
| | - Bin Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry , Wuhan University , Wuhan 430072 , China
| |
Collapse
|
20
|
Salivary Exosome and Cell-Free DNA for Cancer Detection. MICROMACHINES 2018; 9:mi9070340. [PMID: 30424273 PMCID: PMC6082266 DOI: 10.3390/mi9070340] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Revised: 06/29/2018] [Accepted: 07/03/2018] [Indexed: 12/16/2022]
Abstract
Liquid biopsies are easier to acquire patient derived samples than conventional tissue biopsies, and their use enables real-time monitoring of the disease through continuous sampling after initial diagnosis, resulting in a paradigm shift to customized treatment according to the patient’s prognosis. Among the various liquid biopsy samples, saliva is easily obtained by spitting or swab sucking without needing an expert for sample collection. In addition, it is known that disease related biomarkers that exist in the blood and have undergone extensive research exist in saliva even at a lower concentration than the blood. Thus, interest in the use of saliva as a liquid biopsy has increased. In this review, we focused on the salivary exosome and cell-free DNA (cfDNA) among the various biomarkers in saliva. Since the exosome and cfDNA in saliva are present at lower concentrations than the biomarkers in blood, it is important to separate and concentrate them before conducting down-stream analyses such as exosome cargo analysis, quantitative polymerase chain reaction (qPCR), and sequencing. However, saliva is difficult to apply directly to microfluidics-based systems for separation because of its high viscosity and the presence of various foreign substances. Therefore, we reviewed the microfluidics-based saliva pretreatment method and then compared the commercially available kit and the microfluidic chip for isolation and enrichment of the exosome and cfDNA in saliva.
Collapse
|
21
|
Islam MM, Loewen A, Allen PB. Simple, low-cost fabrication of acrylic based droplet microfluidics and its use to generate DNA-coated particles. Sci Rep 2018; 8:8763. [PMID: 29884895 PMCID: PMC5993776 DOI: 10.1038/s41598-018-27037-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Accepted: 05/01/2018] [Indexed: 11/23/2022] Open
Abstract
Hydrogel microparticles were copolymerized with surface-immobilized DNA. Particles derived from a microfluidic device and particles derived from mechanical homogenization were compared. The hypothesis was tested that a controlled droplet generation mechanism would produce more homogeneous particles. Surprisingly, the DNA content of both particle types was similarly inhomogeneous. To make this test possible, a simple, low cost, and rapid method was developed to fabricate a microfluidic chip for droplet generation and in-line polymerization. This method used a low-cost laser cutter ($400) and direct heat bonding (no adhesives or intermediate layers). The flow focusing droplet generator produced droplets and hydrogel particles 10-200 μm in diameter.
Collapse
Affiliation(s)
- Md Mamunul Islam
- University of Idaho, Department of Chemistry, 875 Perimeter Dr., Moscow, ID, 83844-2343, USA
| | - Amanda Loewen
- University of Idaho, Department of Chemistry, 875 Perimeter Dr., Moscow, ID, 83844-2343, USA
| | - Peter B Allen
- University of Idaho, Department of Chemistry, 875 Perimeter Dr., Moscow, ID, 83844-2343, USA.
| |
Collapse
|
22
|
A comprehensive study of a new versatile microchip device based liquid phase microextraction for stopped-flow and double-flow conditions. J Chromatogr A 2018; 1556:29-36. [DOI: 10.1016/j.chroma.2018.04.051] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 04/19/2018] [Accepted: 04/23/2018] [Indexed: 01/02/2023]
|
23
|
Poltorak L, Eggink I, Hoitink M, Sudhölter EJR, de Puit M. Electrified Soft Interface as a Selective Sensor for Cocaine Detection in Street Samples. Anal Chem 2018; 90:7428-7433. [PMID: 29781600 PMCID: PMC6011179 DOI: 10.1021/acs.analchem.8b00916] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
![]()
A straightforward,
direct, and selective method is presented for
electrochemical cocaine identification in street samples. The sensing
mechanism is based on a simple ion transfer reaction across the polarized
liquid–liquid interface. The interfacial behavior of a number
of cutting agents is also reported. Interfacial miniaturization has
led to improved electroanalytical properties of the liquid–liquid
interface based sensor as compared with the macroscopic analogue.
The reported method holds great potential to replace colorimetric
tests with poor selectivity for on-site street sample analysis.
Collapse
Affiliation(s)
- Lukasz Poltorak
- Delft University of Technology , Department of Chemical Engineering , Van der Maasweg 9 , 2629 HZ Delft , The Netherlands
| | | | - Marnix Hoitink
- Delft University of Technology , Department of Chemical Engineering , Van der Maasweg 9 , 2629 HZ Delft , The Netherlands
| | - Ernst J R Sudhölter
- Delft University of Technology , Department of Chemical Engineering , Van der Maasweg 9 , 2629 HZ Delft , The Netherlands
| | - Marcel de Puit
- Delft University of Technology , Department of Chemical Engineering , Van der Maasweg 9 , 2629 HZ Delft , The Netherlands.,Netherlands Forensic Institute, Forensic Biometric Traces , Laan van Ypenburg 6 , 2497 GB The Hague , The Netherlands
| |
Collapse
|
24
|
Haas J, Catalán EV, Piron P, Karlsson M, Mizaikoff B. Infrared spectroscopy based on broadly tunable quantum cascade lasers and polycrystalline diamond waveguides. Analyst 2018; 143:5112-5119. [DOI: 10.1039/c8an00919h] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Recently emerging broadly tunable quantum cascade lasers (tQCL) emitting in the mid-infrared (MIR) are a versatile alternative to well established thermal emitters in combination with interferometers as applied in Fourier transform infrared (FTIR) spectroscopy.
Collapse
Affiliation(s)
- Julian Haas
- Institute of Analytical and Bioanalytical Chemistry
- Ulm University
- 89081 Ulm
- Germany
- Department of Engineering Sciences
| | | | - Pierre Piron
- Department of Engineering Sciences
- Uppsala University
- SE-75121 Uppsala
- Sweden
| | - Mikael Karlsson
- Department of Engineering Sciences
- Uppsala University
- SE-75121 Uppsala
- Sweden
- Molecular Fingerprint Sweden AB
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry
- Ulm University
- 89081 Ulm
- Germany
| |
Collapse
|
25
|
Affiliation(s)
- Cong Xu
- Institute of Nuclear and
New Energy Technology, Collaborative Innovation Center of Advanced
Nuclear Energy Technology, Tsinghua University, Beijing 100084, People’s Republic of China
| | - Tingliang Xie
- Institute of Nuclear and
New Energy Technology, Collaborative Innovation Center of Advanced
Nuclear Energy Technology, Tsinghua University, Beijing 100084, People’s Republic of China
| |
Collapse
|
26
|
Sriram KK, Nayak S, Pengel S, Chou CF, Erbe A. 10 nm deep, sub-nanoliter fluidic nanochannels on germanium for attenuated total reflection infrared (ATR-IR) spectroscopy. Analyst 2017; 142:273-278. [DOI: 10.1039/c6an01699e] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Nanoslits with a depth of ∼10 nm were manufactured on a germanium internal reflection element for attenuated internal reflection infrared spectroscopy.
Collapse
Affiliation(s)
| | - Simantini Nayak
- Max-Planck-Institut für Eisenforschung GmbH
- 40237 Düsseldorf
- Germany
| | - Stefanie Pengel
- Max-Planck-Institut für Eisenforschung GmbH
- 40237 Düsseldorf
- Germany
| | - Chia-Fu Chou
- Institute of Physics
- Academia Sinica
- Taiwan
- Research Centre for Applied Sciences
- Academia Sinica
| | - Andreas Erbe
- Max-Planck-Institut für Eisenforschung GmbH
- 40237 Düsseldorf
- Germany
- Department of Materials Science and Engineering
- NTNU
| |
Collapse
|
27
|
Schwaighofer A, Brandstetter M, Lendl B. Quantum cascade lasers (QCLs) in biomedical spectroscopy. Chem Soc Rev 2017; 46:5903-5924. [DOI: 10.1039/c7cs00403f] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This review focuses on the recent applications of QCLs in mid-IR spectroscopy of clinically relevant samples.
Collapse
Affiliation(s)
- Andreas Schwaighofer
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| | | | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| |
Collapse
|
28
|
Ramos-Payan M, Maspoch S, Llobera A. An effective microfluidic based liquid-phase microextraction device (μLPME) for extraction of non-steroidal anti-inflammatory drugs from biological and environmental samples. Anal Chim Acta 2016; 946:56-63. [DOI: 10.1016/j.aca.2016.09.040] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2016] [Revised: 09/29/2016] [Accepted: 09/29/2016] [Indexed: 12/28/2022]
|
29
|
Asl YA, Yamini Y, Seidi S. Development of a microfluidic-chip system for liquid–phase microextraction based on two immiscible organic solvents for the extraction and preconcentration of some hormonal drugs. Talanta 2016; 160:592-599. [DOI: 10.1016/j.talanta.2016.07.063] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2016] [Revised: 07/26/2016] [Accepted: 07/27/2016] [Indexed: 11/30/2022]
|
30
|
Simultaneous extraction of acidic and basic drugs via on-chip electromembrane extraction. Anal Chim Acta 2016; 937:61-8. [DOI: 10.1016/j.aca.2016.07.048] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 07/24/2016] [Accepted: 07/31/2016] [Indexed: 11/21/2022]
|
31
|
Haas J, Mizaikoff B. Advances in Mid-Infrared Spectroscopy for Chemical Analysis. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2016; 9:45-68. [PMID: 27070183 DOI: 10.1146/annurev-anchem-071015-041507] [Citation(s) in RCA: 118] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Infrared spectroscopy in the 3-20 μm spectral window has evolved from a routine laboratory technique into a state-of-the-art spectroscopy and sensing tool by benefitting from recent progress in increasingly sophisticated spectra acquisition techniques and advanced materials for generating, guiding, and detecting mid-infrared (MIR) radiation. Today, MIR spectroscopy provides molecular information with trace to ultratrace sensitivity, fast data acquisition rates, and high spectral resolution catering to demanding applications in bioanalytics, for example, and to improved routine analysis. In addition to advances in miniaturized device technology without sacrificing analytical performance, selected innovative applications for MIR spectroscopy ranging from process analysis to biotechnology and medical diagnostics are highlighted in this review.
Collapse
Affiliation(s)
- Julian Haas
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89069 Ulm, Germany;
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89069 Ulm, Germany;
| |
Collapse
|
32
|
Affiliation(s)
- Markus Sieger
- Institute
of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Boris Mizaikoff
- Institute
of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| |
Collapse
|
33
|
Alhusban AA, Breadmore MC, Gueven N, Guijt RM. Capillary electrophoresis for automated on-line monitoring of suspension cultures: Correlating cell density, nutrients and metabolites in near real-time. Anal Chim Acta 2016; 920:94-101. [PMID: 27114228 DOI: 10.1016/j.aca.2016.03.034] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 03/17/2016] [Accepted: 03/19/2016] [Indexed: 11/29/2022]
Abstract
Increasingly stringent demands on the production of biopharmaceuticals demand monitoring of process parameters that impact on their quality. We developed an automated platform for on-line, near real-time monitoring of suspension cultures by integrating microfluidic components for cell counting and filtration with a high-resolution separation technique. This enabled the correlation of the growth of a human lymphocyte cell line with changes in the essential metabolic markers, glucose, glutamine, leucine/isoleucine and lactate, determined by Sequential Injection-Capillary Electrophoresis (SI-CE). Using 8.1 mL of media (41 μL per run), the metabolic status and cell density were recorded every 30 min over 4 days. The presented platform is flexible, simple and automated and allows for fast, robust and sensitive analysis with low sample consumption and high sample throughput. It is compatible with up- and out-scaling, and as such provides a promising new solution to meet the future demands in process monitoring in the biopharmaceutical industry.
Collapse
Affiliation(s)
- Ala A Alhusban
- School of Medicine, Faculty of Health Sciences, University of Tasmania, Australia; Australian Center of Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Australia; School of Medicine and ACROSS, Faculty of Health Sciences, University of Tasmania, Australia
| | - Michael C Breadmore
- Australian Center of Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Australia
| | - Nuri Gueven
- School of Medicine, Faculty of Health Sciences, University of Tasmania, Australia
| | - Rosanne M Guijt
- School of Medicine, Faculty of Health Sciences, University of Tasmania, Australia; School of Medicine and ACROSS, Faculty of Health Sciences, University of Tasmania, Australia.
| |
Collapse
|
34
|
Microfluidic distillation chip for methanol concentration detection. Anal Chim Acta 2016; 912:97-104. [DOI: 10.1016/j.aca.2016.01.047] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Revised: 01/22/2016] [Accepted: 01/26/2016] [Indexed: 12/11/2022]
|
35
|
Sieger M, Haas J, Jetter M, Michler P, Godejohann M, Mizaikoff B. Mid-Infrared Spectroscopy Platform Based on GaAs/AlGaAs Thin-Film Waveguides and Quantum Cascade Lasers. Anal Chem 2016; 88:2558-62. [DOI: 10.1021/acs.analchem.5b04144] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Markus Sieger
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Julian Haas
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Michael Jetter
- Institut
für Halbleiteroptik und Funktionelle Grenzflächen, Universität Stuttgart, Allmandring 3, 70565 Stuttgart, Germany
| | - Peter Michler
- Institut
für Halbleiteroptik und Funktionelle Grenzflächen, Universität Stuttgart, Allmandring 3, 70565 Stuttgart, Germany
| | | | - Boris Mizaikoff
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| |
Collapse
|
36
|
Community Sewage Sensors towards Evaluation of Drug Use Trends: Detection of Cocaine in Wastewater with DNA-Directed Immobilization Aptamer Sensors. Sci Rep 2016; 6:21024. [PMID: 26876971 PMCID: PMC4753446 DOI: 10.1038/srep21024] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Accepted: 01/14/2016] [Indexed: 12/04/2022] Open
Abstract
Illicit drug use has a global concern and effective monitoring and interventions are highly required to combat drug abuse. Wastewater-based epidemiology (WBE) is an innovative and cost-effective approach to evaluate community-wide drug use trends, compared to traditional population surveys. Here we report for the first time, a novel quantitative community sewage sensor (namely DNA-directed immobilization of aptamer sensors, DDIAS) for rapid and cost-effective estimation of cocaine use trends via WBE. Thiolated single-stranded DNA (ssDNA) probe was hybridized with aptamer ssDNA in solution, followed by co-immobilization with 6-mercapto-hexane onto the gold electrodes to control the surface density to effectively bind with cocaine. DDIAS was optimized to detect cocaine at as low as 10 nM with a dynamic range from 10 nM to 5 μM, which were further employed for the quantification of cocaine in wastewater samples collected from a wastewater treatment plant in seven consecutive days. The concentration pattern of the sampling week is comparable with that from mass spectrometry. Our results demonstrate that the developed DDIAS can be used as community sewage sensors for rapid and cost-effective evaluation of drug use trends, and potentially implemented as a powerful tool for on-site and real-time monitoring of wastewater by un-skilled personnel.
Collapse
|
37
|
Affiliation(s)
- Sheng Tang
- Department
of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore
| | - Hong Zhang
- Department
of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore
| | - Hian Kee Lee
- Department
of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore
- National University of Singapore Environmental Research Institute, T-Lab Building #02-01, 5A Engineering
Drive 1, Singapore 117411, Singapore
- Tropical
Marine Science Institute, National University of Singapore, S2S, 18
Kent Ridge Road, Singapore 119227, Singapore
| |
Collapse
|
38
|
Wang H, Liu Y, Wei S, Yao S, Zhang J, Huang H. Selective extraction and determination of fluoroquinolones in bovine milk samples with montmorillonite magnetic molecularly imprinted polymers and capillary electrophoresis. Anal Bioanal Chem 2015; 408:589-98. [PMID: 26542835 DOI: 10.1007/s00216-015-9140-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 10/08/2015] [Accepted: 10/21/2015] [Indexed: 02/06/2023]
Abstract
A sensitive and selective method for separating fluoroquinolones (FQs) from bovine milk samples was successfully developed using montmorillonite magnetic molecularly imprinted polymers (MMMIPs) as adsorbents. MMMIPs were prepared using montmorillonite as carrier, fleroxacin (FLE) as template molecule, and Fe3O4 magnetite as magnetic component. MMMIPs possessed high adsorption capacity of 46.3 mg g(-1) for FLE. A rapid and convenient magnetic solid-phase extraction procedure coupled with capillary electrophoresis was established with MMMIPs as adsorbents for simultaneous and selective extraction of four FQs in bovine milk samples. Limits of detection ranged between 12.9 and 18.8 μg L(-1), and the RSDs were between 1.8% and 8.6%. The proposed method was successfully applied to spike bovine milk samples with recoveries of 92.7%-108.6%.
Collapse
Affiliation(s)
- Hongwu Wang
- School of Chemistry & Chemical Engineering, Zhaoqing University, Zhaoqing, 526061, China.
| | - Yanqing Liu
- School of Chemistry & Chemical Engineering, Zhaoqing University, Zhaoqing, 526061, China
| | - Shoulian Wei
- School of Chemistry & Chemical Engineering, Zhaoqing University, Zhaoqing, 526061, China.
| | - Su Yao
- School of Chemistry & Chemical Engineering, Zhaoqing University, Zhaoqing, 526061, China
| | - Jiali Zhang
- Department of Chemistry, East China Jiaotong University, Nanchang, 330013, China
| | - Huichang Huang
- School of Chemistry & Chemical Engineering, Zhaoqing University, Zhaoqing, 526061, China
| |
Collapse
|
39
|
Abdossalami Asl Y, Yamini Y, Seidi S, Ebrahimpour B. A new effective on chip electromembrane extraction coupled with high performance liquid chromatography for enhancement of extraction efficiency. Anal Chim Acta 2015; 898:42-9. [DOI: 10.1016/j.aca.2015.09.052] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2015] [Revised: 09/18/2015] [Accepted: 09/28/2015] [Indexed: 10/22/2022]
|
40
|
|
41
|
Kokosa JM. Recent trends in using single-drop microextraction and related techniques in green analytical methods. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.04.019] [Citation(s) in RCA: 99] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
42
|
Poulsen CE, Wootton RCR, Wolff A, deMello AJ, Elvira KS. A Microfluidic Platform for the Rapid Determination of Distribution Coefficients by Gravity-Assisted Droplet-Based Liquid–Liquid Extraction. Anal Chem 2015; 87:6265-70. [DOI: 10.1021/acs.analchem.5b01061] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Carl Esben Poulsen
- Department
of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Robert C. R. Wootton
- Institute
of Chemical and Bioengineering, Department of Chemistry and Applied
Biosciences, ETH Zurich, Zurich, Switzerland
| | - Anders Wolff
- Department
of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Andrew J. deMello
- Institute
of Chemical and Bioengineering, Department of Chemistry and Applied
Biosciences, ETH Zurich, Zurich, Switzerland
| | - Katherine S. Elvira
- Institute
of Chemical and Bioengineering, Department of Chemistry and Applied
Biosciences, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
43
|
Wang WT, Sang FN, Xu JH, Wang YD, Luo GS. The enhancement of liquid–liquid extraction with high phase ratio by microfluidic-based hollow droplet. RSC Adv 2015. [DOI: 10.1039/c5ra15769b] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
We developed a novel method to enhance the liquid–liquid extraction by a microfluidic-based hollow droplet structure. A one-step microfluidic device is used for the generation of gas-in-oil-in-water double emulsions.
Collapse
Affiliation(s)
- Wen-Ting Wang
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Fu-Ning Sang
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Jian-Hong Xu
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Yun-Dong Wang
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| | - Guang-Sheng Luo
- The State Key Lab of Chemical Engineering
- Department of Chemical Engineering
- Tsinghua University
- Beijing 100084
- China
| |
Collapse
|
44
|
Hendrickx S, de Malsche W, Cabooter D. An overview of the use of microchips in electrophoretic separation techniques: fabrication, separation modes, sample preparation opportunities, and on-chip detection. Methods Mol Biol 2015; 1274:3-17. [PMID: 25673478 DOI: 10.1007/978-1-4939-2353-3_1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This chapter is intended as a basic introduction to microchip-based capillary electrophoresis to set the scene for newcomers and give pointers to reference material. An outline of some commonly used setups and key concepts is given, many of which are explored in greater depth in later chapters.
Collapse
Affiliation(s)
- Stijn Hendrickx
- Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven, O&N2 923, Herestraat 49, 3000, Leuven, Belgium
| | | | | |
Collapse
|
45
|
|
46
|
Electrokinetics for sample preparation of biological molecules in biological samples using microfluidic systems. Bioanalysis 2014; 6:1961-74. [DOI: 10.4155/bio.14.140] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Sample preparation is the first part of every analytical method, but is often considered only after the optimization of the method. It is traditionally performed using a range of techniques requiring extensive manual handling, with solid-phase extraction, liquid–liquid extraction, protein precipitation and ultracentrfiguation, among others, being used depending on the targets and the application. In this article, we will focus on alternatives based on electrokinetics for applications including sample clean-up, concentration and derivatization of large biological molecules (DNA, peptides and proteins) of diagnostic importance, as well as small molecules as a tool for therapeutic drug monitoring. This article describes these approaches in terms of mechanisms, applicability and potential to be integrated into a lab-on-a-chip device for directly processing biological samples. Examples dealing with treated or clean samples have been excluded except where they show exceptionally high value.
Collapse
|
47
|
Gibb TR, Ivanov AP, Edel JB, Albrecht T. Single Molecule Ionic Current Sensing in Segmented Flow Microfluidics. Anal Chem 2014; 86:1864-71. [DOI: 10.1021/ac403921m] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Thomas R. Gibb
- Department of Chemistry, Imperial College London, South Kensington Campus, London, SW7
2AZ, United Kingdom
| | - Aleksandar P. Ivanov
- Department of Chemistry, Imperial College London, South Kensington Campus, London, SW7
2AZ, United Kingdom
| | - Joshua B. Edel
- Department of Chemistry, Imperial College London, South Kensington Campus, London, SW7
2AZ, United Kingdom
| | - Tim Albrecht
- Department of Chemistry, Imperial College London, South Kensington Campus, London, SW7
2AZ, United Kingdom
| |
Collapse
|
48
|
Jouy P, Mangold M, Tuzson B, Emmenegger L, Chang YC, Hvozdara L, Herzig HP, Wägli P, Homsy A, de Rooij NF, Wirthmueller A, Hofstetter D, Looser H, Faist J. Mid-infrared spectroscopy for gases and liquids based on quantum cascade technologies. Analyst 2014; 139:2039-46. [DOI: 10.1039/c3an01462b] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|