1
|
Qiu Y, Cai X, Bian X, Hu G. Design of a magnetically responsive artificial cilia array platform for microsphere transport. LAB ON A CHIP 2024. [PMID: 39676634 DOI: 10.1039/d4lc00981a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2024]
Abstract
We present an innovative platform designed to mimic the mucociliary clearance system, an essential defense mechanism in the respiratory tract. Our system utilizes PDMS and iron powder to fabricate micro-ciliary arrays that dynamically respond to alternating magnetic fields. The cilia exhibit an asymmetric beating pattern under a cyclically varying magnetic field, which propels microspheres directionally in a fluid medium, simulating the movement of mucus. We use both experimental setups and numerical simulations to investigate factors that influence the efficiency of particle transport, such as cilia beating frequency, microsphere size, cilia density, and fluid viscosity. Our results elucidate the role of artificial cilia in surface cleaning processes and provide insights that enhance our understanding of mucociliary clearance. This novel experimental platform holds great promise for advancing research in respiratory health and microchannel cleaning technologies, and contributes to our ability to model and study human respiratory function in vitro.
Collapse
Affiliation(s)
- Yan Qiu
- Department of Engineering Mechanics, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China.
| | - Xinwei Cai
- Department of Engineering Mechanics, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China.
| | - Xin Bian
- Department of Engineering Mechanics, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China.
| | - Guoqing Hu
- Department of Engineering Mechanics, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China.
| |
Collapse
|
2
|
Hu X, Yu L, Zhu Z, Bao F, Lin J, Tu C, Lin P. A self-cleaning micro-fluidic chip biospired by the filtering system of manta rays. LAB ON A CHIP 2024; 24:3064-3079. [PMID: 38757493 DOI: 10.1039/d4lc00039k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Size-based particle filtration has become indispensable in numerous biomedical and environmental applications. In this study, bioinspired by the filter-feeding mechanism (lobe filtration) of manta rays, we designed a U-shaped biomimetic gill rake filter that combined lobe filtration and Dean flow to filter monodisperse suspensions, bi-disperse suspensions and yeast cells. Compared with other equipment using the inertial focusing technology, our equipment can perform high-throughput (up to 8 mL min-1) and high-efficiency filtration of particles (maximum filtration efficiencies of 96.08% and 97.14% for 10 and 15 μm monodisperse suspensions at the optimum flow rate of 6 mL min-1). The complex velocity field of the micro-fluidic flow within the filter is numerically simulated, and in combination with experiments, a threshold for the flow rate is identified. When the inlet flow rate exceeds the threshold value, the efficiency of particle filtration is increased rapidly. Afterwards, by analysing the filtration mechanism, we develop three novel filtration processes. The equilibrium positions of the particles and yeast cells in the main channel are close to the outer wall at high flow rate, which diminishes the likelihood of particles and yeast cells entering the side channel. This configuration establishes a self-cleaning mechanism, ensuring prolonged and efficient operation of the filter with high-throughput processing. Furthermore, the influence of the filter lobe angle and channel width on the filtration efficiency and outlet flow rate ratio are explored, and an optimisation plan is prepared.
Collapse
Affiliation(s)
- Xiao Hu
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| | - Longfei Yu
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| | - Zuchao Zhu
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| | - Fubing Bao
- Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou, Zhejiang 310027, PR China.
| | - Jianzhong Lin
- Zhejiang Provincial Engineering Research Center for the Safety of Pressure Vessels and Pipelines, Ningbo University, Ningbo, Zhejiang 315211, PR China
| | - Chengxu Tu
- Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou, Zhejiang 310027, PR China.
| | - Peifeng Lin
- Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, PR China.
| |
Collapse
|
3
|
Wang D, Jin K, Ji J, Hu C, Du M, Belgaid Y, Shi S, Li J, Hu S, Nathan A, Yu J, Ma H. Active-matrix digital microfluidics design for field programmable high-throughput digitalized liquid handling. iScience 2024; 27:109324. [PMID: 38706854 PMCID: PMC11067379 DOI: 10.1016/j.isci.2024.109324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 01/12/2024] [Accepted: 02/20/2024] [Indexed: 05/07/2024] Open
Abstract
Digital liquid sample handling is an enabling tool for cutting-edge life-sciences research. We present here an active-matrix thin-film transistor (TFT) based digital microfluidics system, referred to as Field Programmable Droplet Array (FPDA). The system contains 256 × 256 pixels in an active area of 10.65 cm2, which can manipulate thousands of addressable liquid droplets simultaneously. By leveraging a novel TFT device and circuits design solution, we manage to programmatically manipulate droplets at single-pixel level. The minimum achievable droplet volume is around 0.5 nL, which is two orders of magnitude smaller than the smallest droplet ever reported on active-matrix digital microfluidics. The movement of droplets can be either pre-programmed or controlled in real-time. The FPDA system shows great potential of the ubiquitous thin-film electronics technology in digital liquid handling. These efforts will make it possible to create a true programmable lab-on-a-chip device to enable great advances in life science research.
Collapse
Affiliation(s)
- Dongping Wang
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, P.R. China
| | - Kai Jin
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, P.R. China
| | - Jiajian Ji
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, P.R. China
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, P.R. China
| | - Chenxuan Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, P.R. China
| | - Maohua Du
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Foshan 528000, P.R. China
| | | | - Subao Shi
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Foshan 528000, P.R. China
| | - Jiahao Li
- ACX Instruments Ltd, Cambridge CB4 0WS, UK
| | - Siyi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, P.R. China
| | - Arokia Nathan
- School of Information Science and Engineering, Shandong University, Qingdao 266237, P.R. China
| | - Jun Yu
- School of Information Science and Engineering, Shandong University, Qingdao 266237, P.R. China
| | - Hanbin Ma
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, P.R. China
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Foshan 528000, P.R. China
| |
Collapse
|
4
|
Yang Q, Li S, Ou H, Zhang Y, Zhu G, Li S, Lei L. Exosome-based delivery strategies for tumor therapy: an update on modification, loading, and clinical application. J Nanobiotechnology 2024; 22:41. [PMID: 38281957 PMCID: PMC10823703 DOI: 10.1186/s12951-024-02298-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 01/02/2024] [Indexed: 01/30/2024] Open
Abstract
Malignancy is a major public health problem and among the leading lethal diseases worldwide. Although the current tumor treatment methods have therapeutic effect to a certain extent, they still have some shortcomings such as poor water solubility, short half-life, local and systemic toxicity. Therefore, how to deliver therapeutic agent so as to realize safe and effective anti-tumor therapy become a problem urgently to be solved in this field. As a medium of information exchange and material transport between cells, exosomes are considered to be a promising drug delivery carrier due to their nano-size, good biocompatibility, natural targeting, and easy modification. In this review, we summarize recent advances in the isolation, identification, drug loading, and modification of exosomes as drug carriers for tumor therapy alongside their application in tumor therapy. Basic knowledge of exosomes, such as their biogenesis, sources, and characterization methods, is also introduced herein. In addition, challenges related to the use of exosomes as drug delivery vehicles are discussed, along with future trends. This review provides a scientific basis for the application of exosome delivery systems in oncological therapy.
Collapse
Affiliation(s)
- Qian Yang
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, Hunan, China
| | - Shisheng Li
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, Hunan, China.
| | - Haibo Ou
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, Hunan, China
| | - Yuming Zhang
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, Hunan, China
| | - Gangcai Zhu
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, Hunan, China
| | - Shaohong Li
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha, 410011, Hunan, China.
| | - Lanjie Lei
- Institute of Translational Medicine, Zhejiang Shuren University, Hangzhou, 310015, Zhejiang, China.
| |
Collapse
|
5
|
Cutuli E, Sanalitro D, Stella G, Saitta L, Bucolo M. A 3D-Printed Micro-Optofluidic Chamber for Fluid Characterization and Microparticle Velocity Detection. MICROMACHINES 2023; 14:2115. [PMID: 38004972 PMCID: PMC10673365 DOI: 10.3390/mi14112115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 10/30/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023]
Abstract
This work proposes a multi-objective polydimethylsiloxane (PDMS) micro-optofluidic (MoF) device suitably designed and manufactured through a 3D-printed-based master-slave approach. It exploits optical detection techniques to characterize immiscible fluids or microparticles in suspension inside a compartment specifically designed at the core of the device referred to as the MoF chamber. In addition, we show our novel, fast, and cost-effective methodology, dual-slit particle signal velocimetry (DPSV), for fluids and microparticle velocity detection. Different from the standard state-of-the-art approaches, the methodology focuses on signal processing rather than image processing. This alternative has several advantages, including the ability to circumvent the requirement of complex and extensive setups and cost reduction. Additionally, its rapid processing speed allows for real-time sample manipulations in ongoing image-based analyses. For our specific design, optical signals have been detected from the micro-optics components placed in two slots designed ad hoc in the device. To show the devices' multipurpose capabilities, the device has been tested with fluids of various colors and densities and the inclusion of synthetic microparticles. Additionally, several experiments have been conducted to prove the effectiveness of the DPSV approach in estimating microparticle velocities. A digital particle image velocimetry (DPIV)-based approach has been used as a baseline against which the outcomes of our methods have been evaluated. The combination of the suitability of the micro-optical components for integration, along with the MoF chamber device and the DPSV approach, demonstrates a proof of concept towards the challenge of real-time total-on-chip analysis.
Collapse
Affiliation(s)
- Emanuela Cutuli
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| | - Dario Sanalitro
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| | - Giovanna Stella
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| | - Lorena Saitta
- Department of Civil Engineering and Architecture, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy;
| | - Maide Bucolo
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| |
Collapse
|
6
|
Saar I, Evard H. Screen Printed Particle-Based Microfluidics: Optimization and Exemplary Application for Heavy Metals Analysis. MICROMACHINES 2023; 14:1369. [PMID: 37512680 PMCID: PMC10386728 DOI: 10.3390/mi14071369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 06/29/2023] [Accepted: 07/02/2023] [Indexed: 07/30/2023]
Abstract
In this work, a screen-printing method was developed to create porous particle-based materials as layers with specifically designed shape to produce microfluidics systems. Among several tested binding agents, xanthan gum was found to be an excellent choice for a printing mixture thickener as well as a durable binder for the resulting material. In addition to demonstrating control over the shape of the printed microfluidics chips, control over material thickness, wetting characteristics and general method accuracy were also investigated. The applicability of the introduced method was further demonstrated with a development of an exemplary microfluidics chip for quantitative detection of Fe (III), Ni (II), Cu (II), Cd (II), and Pb (II) from a mixed sample at millimolar levels. The novel approaches demonstrated in this article offer new perspective into creating multiplexed on-site chemical analysis tests.
Collapse
Affiliation(s)
- Indrek Saar
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia
| | - Hanno Evard
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411 Tartu, Estonia
| |
Collapse
|
7
|
Jurina T, Sokač Cvetnić T, Šalić A, Benković M, Valinger D, Gajdoš Kljusurić J, Zelić B, Jurinjak Tušek A. Application of Spectroscopy Techniques for Monitoring (Bio)Catalytic Processes in Continuously Operated Microreactor Systems. Catalysts 2023. [DOI: 10.3390/catal13040690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023] Open
Abstract
In the last twenty years, the application of microreactors in chemical and biochemical industrial processes has increased significantly. The use of microreactor systems ensures efficient process intensification due to the excellent heat and mass transfer within the microchannels. Monitoring the concentrations in the microchannels is critical for a better understanding of the physical and chemical processes occurring in micromixers and microreactors. Therefore, there is a growing interest in performing in-line and on-line analyses of chemical and/or biochemical processes. This creates tremendous opportunities for the incorporation of spectroscopic detection techniques into production and processing lines in various industries. In this work, an overview of current applications of ultraviolet–visible, infrared, Raman spectroscopy, NMR, MALDI-TOF-MS, and ESI-MS for monitoring (bio)catalytic processes in continuously operated microreactor systems is presented. The manuscript includes a description of the advantages and disadvantages of the analytical methods listed, with particular emphasis on the chemometric methods used for spectroscopic data analysis.
Collapse
Affiliation(s)
- Tamara Jurina
- Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva ul. 6, 10 000 Zagreb, Croatia
| | - Tea Sokač Cvetnić
- Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva ul. 6, 10 000 Zagreb, Croatia
| | - Anita Šalić
- Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10 000 Zagreb, Croatia
| | - Maja Benković
- Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva ul. 6, 10 000 Zagreb, Croatia
| | - Davor Valinger
- Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva ul. 6, 10 000 Zagreb, Croatia
| | - Jasenka Gajdoš Kljusurić
- Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva ul. 6, 10 000 Zagreb, Croatia
| | - Bruno Zelić
- Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10 000 Zagreb, Croatia
- Department for Packaging, Recycling and Environmental Protection, University North, Trg dr. Žarka Dolinara 1, 48 000 Koprivnica, Croatia
| | - Ana Jurinjak Tušek
- Faculty of Food Technology and Biotechnology, University of Zagreb, Pierottijeva ul. 6, 10 000 Zagreb, Croatia
| |
Collapse
|
8
|
Wu Y, Wang Y, Lu Y, Luo X, Huang Y, Xie T, Pilarsky C, Dang Y, Zhang J. Microfluidic Technology for the Isolation and Analysis of Exosomes. MICROMACHINES 2022; 13:1571. [PMID: 36295924 PMCID: PMC9607600 DOI: 10.3390/mi13101571] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 09/14/2022] [Accepted: 09/19/2022] [Indexed: 06/16/2023]
Abstract
Exosomes are lipid-bilayer enclosed vesicles with diameters of 30-150 nm, which play a pivotal role in cell communication by transporting their cargoes such as proteins, lipids, and genetic materials. In recent years, exosomes have been under intense investigation, as they show great promise in numerous areas, especially as bio-markers in liquid biopsies. However, due to the high heterogeneity and the nano size of exosomes, the separation of exosomes is not easy. This review will deliver an outline of the conventional methods and the microfluidic-based technologies for exosome separation. Particular attention is devoted to microfluidic devices, highlighting the efficiency of exosome isolation by these methods. Additionally, this review will introduce advances made in the integrated microfluidics technologies that enable the separation and analysis of exosomes.
Collapse
Affiliation(s)
- Yusong Wu
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| | - Yuqing Wang
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| | - Yanjun Lu
- Guangdong Provincial Key Laboratory of Micro/Nano Optomechatronics Engineering, College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen 518060, China
| | - Xiaomei Luo
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| | - Yinghong Huang
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| | - Ting Xie
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| | - Christian Pilarsky
- Department of Surgery, Friedrich-Alexander University of Erlangen-Nuremberg (FAU), University Hospital of Erlangen, 91054 Erlangen, Germany
| | - Yuanye Dang
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| | - Jianye Zhang
- Guangzhou Municipal and Guangdong Provincial Key Laboratory of Molecular Target & Clinical Pharmacology, NMPA and State Key Laboratory of Respiratory Disease, School of Pharmaceutical Sciences and the Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| |
Collapse
|
9
|
Yang Y, Chen R, Zhu X, Ye D, Yang Y, Li W, Li D, Li H, Liao Q. Micro-object manipulation by decanol liquid lenses. LAB ON A CHIP 2022; 22:2844-2852. [PMID: 35829651 DOI: 10.1039/d2lc00386d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The flexible and precise manipulation of droplets on an air-liquid interface with complex functions remains challenging. Herein, we propose a smart strategy for excellently manipulating target droplets by decanol liquid lenses. A moveable surface tension gradient field generated by decanol liquid lenses is responsible for realizing various functions of transportation, launching and splitting of target droplets. With such fascinating features, directional long-distance transportation and on-demand droplet coalescence are enabled. Moreover, paw-like liquid lenses are constructed, which realizes a complex process, including collection, capture, transportation and release of target droplets. Remarkably, this strategy can also be applied to manipulate particles and liquid marbles other than droplets, eliminating the limitation of object properties. This work offers a smart strategy for manipulating micro-objects, which shows great potential in applications such as lab-on-a-chip, diagnostics, analytical chemistry and bioengineering, etc.
Collapse
Affiliation(s)
- Yijing Yang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Rong Chen
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Xun Zhu
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Dingding Ye
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Yang Yang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Wei Li
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Dongliang Li
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Haonan Li
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Qiang Liao
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China.
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| |
Collapse
|
10
|
A Review on Potential Electrochemical Point-of-Care Tests Targeting Pandemic Infectious Disease Detection: COVID-19 as a Reference. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070269] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Fast and accurate point-of-care testing (POCT) of infectious diseases is crucial for diminishing the pandemic miseries. To fight the pandemic coronavirus disease 2019 (COVID-19), numerous interesting electrochemical point-of-care (POC) tests have been evolved to rapidly identify the causal organism SARS-CoV-2 virus, its nucleic acid and antigens, and antibodies of the patients. Many of those electrochemical biosensors are impressive in terms of miniaturization, mass production, ease of use, and speed of test, and they could be recommended for future applications in pandemic-like circumstances. On the other hand, self-diagnosis, sensitivity, specificity, surface chemistry, electrochemical components, device configuration, portability, small analyzers, and other features of the tests can yet be improved. Therefore, this report reviews the developmental trend of electrochemical POC tests (i.e., test platforms and features) reported for the rapid diagnosis of COVID-19 and correlates any significant advancements with relevant references. POCTs incorporating microfluidic/plastic chips, paper devices, nanomaterial-aided platforms, smartphone integration, self-diagnosis, and epidemiological reporting attributes are also surfed to help with future pandemic preparedness. This review especially screens the low-cost and easily affordable setups so that management of pandemic disease becomes faster and easier. Overall, the review is a wide-ranging package for finding appropriate strategies of electrochemical POCT targeting pandemic infectious disease detection.
Collapse
|
11
|
He S, Cui R, Zhang Y, Yang Y, Xu Z, Wang S, Dang P, Dang K, Ye Q, Liu Y. Design and Realization of Triple dsDNA Nanocomputing Circuits in Microfluidic Chips. ACS APPLIED MATERIALS & INTERFACES 2022; 14:10721-10728. [PMID: 35188362 DOI: 10.1021/acsami.1c24220] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
DNA logic gates, nanocomputing circuits, have already implemented basic computations and shown great signal potential for nano logic material application. However, the reaction temperature and computing speed still limit its development. Performing complicated computations requires a more stable component and a better computing platform. We proposed a more stable design of logic gates based on a triple, double-stranded, DNA (T-dsDNA) structure. We demonstrated a half adder and a full adder using these DNA nanocircuits and performed the computations in a microfluidic chip device at room temperature. When the solutions were mixed in the device, we obtained the expected results in real time, which suggested that the T-dsDNA combined microfluidic chip provides a concise strategy for large DNA nanocircuits.
Collapse
Affiliation(s)
- Songlin He
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
- Institute of Orthopedics, the First Medical Center, Chinese PLA General Hospital; Beijing Key Lab of Regenerative Medicine in Orthopedics; Key Laboratory of Musculoskeletal Trauma & War Injuries PLA; No. 28 Fuxing Road, Haidian District, Beijing 100853, People's Republic of China
| | - Ruiming Cui
- Key Laboratory of Weak-Light Nonlinear Photonics, Ministry of Education, School of Physics and TEDA Applied Physics, Nankai University, Tianjin 300071, People's Republic of China
| | - Yao Zhang
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
| | - Yongkang Yang
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
| | - Ziheng Xu
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
| | - Shuoyu Wang
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
| | - Pingxiu Dang
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
| | - Kexin Dang
- Key Laboratory of Weak-Light Nonlinear Photonics, Ministry of Education, School of Physics and TEDA Applied Physics, Nankai University, Tianjin 300071, People's Republic of China
| | - Qing Ye
- Key Laboratory of Weak-Light Nonlinear Photonics, Ministry of Education, School of Physics and TEDA Applied Physics, Nankai University, Tianjin 300071, People's Republic of China
- Nankai University Eye Institute, Nankai University, Tianjin 300071, People's Republic of China
| | - Yin Liu
- School of Medicine, Nankai University, Tianjin 300071, People's Republic of China
- Nankai University Eye Institute, Nankai University, Tianjin 300071, People's Republic of China
| |
Collapse
|
12
|
Li N, Zhang Y, Shen M, Xu Y. A fully integrated SNP genotyping system for hereditary hearing-loss detection. LAB ON A CHIP 2022; 22:697-708. [PMID: 34923580 DOI: 10.1039/d1lc00805f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hereditary hearing loss is one of the most common human neurosensory disorders, and there is a great need for early intervention methods such as genetically screening newborns. Single nucleotide polymorphisms (SNPs) are the major genetic targets for hearing-loss screening. In this study, a fully integrated SNP genotyping system was constructed to identify hereditary hearing loss-related genetic markers from human whole blood. The entire detection process, including blood cell lysis, nucleic acid extraction, the reaction mixture distribution, the chambers sealing and the two-colour multiplex competitive allele-specific polymerase chain reaction (KASP), can be automatically conducted in a self-contained cassette within 3 hours. To critically evaluate the performance of the system, its specificity, sensitivity and stability were assessed. Then, 13 clinical samples were genotyped with this fluidic cassette system to detect seven hotspot deafness-associated mutations in three genes (MT-RNR1, GJB2 and SLC26A4). The detection results of the cassette system were 100% concordant with those obtained by Sanger sequencing, proving its accuracy in the genetic screening of inherited hearing loss.
Collapse
Affiliation(s)
- Nan Li
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | - Yuanyue Zhang
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | - Minjie Shen
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | - Youchun Xu
- State Key Laboratory of Membrane Biology, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
13
|
Chakraborty R, Maiti A, Sharma N, Dey KK. Active matter dynamics in confined microfluidic environments. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:245-265. [PMID: 35033287 DOI: 10.1016/bs.pmbts.2021.07.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The field of active matter is a nascent area of research in soft condensed matter physics, which is drawing on the expertise of researchers from diverse disciplines. Small scale active particles-both inorganic and biological-display non-trivial emergent dynamics and interactions that could help us understand complex biological processes and phenomena. Recently, using microfluidic technologies, several research groups have performed important experimental and theoretical studies to understand the behavior of self-propelled particles and molecular active matter within confined environments-to glean a fundamental understanding of the cellular processes occurring under ultra-low Reynolds number conditions. In this chapter, we would like to review applications of microfluidics in active matter research, highlighting a few important theoretical and experimental investigations. We will conclude the discussion with a note on the future of this field mentioning a few open questions that are at the forefront of our minds.
Collapse
Affiliation(s)
- Rik Chakraborty
- Discipline of Physics, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat, India
| | - Arnab Maiti
- Discipline of Physics, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat, India
| | - Nikita Sharma
- Discipline of Physics, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat, India
| | - Krishna Kanti Dey
- Discipline of Physics, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat, India.
| |
Collapse
|
14
|
Duarte LC, Pereira I, Maciel LIL, Vaz BG, Coltro WKT. 3D printed microfluidic mixer for real-time monitoring of organic reactions by direct infusion mass spectrometry. Anal Chim Acta 2022; 1190:339252. [PMID: 34857139 DOI: 10.1016/j.aca.2021.339252] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 08/31/2021] [Accepted: 11/03/2021] [Indexed: 12/26/2022]
Abstract
3D printing is a technology that has revolutionized traditional rapid prototyping methods due to its ability to build microscale structures with customized geometries in a simple, fast, and low-cost way. In this sense, this article describes the development of a microfluidic mixing device to monitor chemical reactions by mass spectrometry (MS). Microfluidic mixers were designed containing 3D serpentine and Y-shaped microchannels, both with a pointed end for facilitating the spray formation. The devices were fabricated entirely by 3D printing with fusion deposition modeling (FDM) technology. As proof-of-concept, micromixers were evaluated through monitoring the Katritzky reaction by injecting simultaneously 2,4,6-triphenylpropyllium (TPP) and amino acid (glycine or alanine) solutions, each through a different reactor inlet. Reaction product was monitored online by MS at different flow rates. Mass spectra showed that the relative abundances of the products obtained with the device containing the 3D serpentine channel were three times greater than those obtained with the Y-channel device due to the turbulence generated by the barriers created inside microchannels. In addition, when compared to the conventional electrospray ionization mass spectrometry (ESI-MS) technique, the 3D serpentine mixer offered better performance measured in relation to the relative abundance values for the reaction products. These results as well as the instrumental simplicity indicate that 3D printed microfluidic mixer is a promising tool for monitoring organic reactions via MS.
Collapse
Affiliation(s)
- Lucas C Duarte
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Igor Pereira
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Lanaia I L Maciel
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Boniek G Vaz
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil.
| |
Collapse
|
15
|
Mani S, Sevanan M, Krishnamoorthy A, Sekar S. A systematic review of molecular approaches that link mitochondrial dysfunction and neuroinflammation in Parkinson's disease. Neurol Sci 2021; 42:4459-4469. [PMID: 34480241 DOI: 10.1007/s10072-021-05551-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 08/07/2021] [Indexed: 02/06/2023]
Abstract
Parkinson's disease (PD) is a chronic and progressive neurodegenerative disorder that affects 1% of the population worldwide. Etiology of PD is likely to be multi-factorial such as protein misfolding, mitochondrial dysfunction, oxidative stress, and neuroinflammation that contributes to the pathology of Parkinson's disease (PD), numerous studies have shown that mitochondrial dysfunction may play a key role in the dopaminergic neuronal loss. In multiple ways, the two most important are the activation of neuroinflammation and mitochondrial dysfunction, while mitochondrial dysfunction could cause neuroinflammation and vice versa. Thus, the mitochondrial proteins are the highly promising target for the development of PD. However, the limited amount of dopaminergic neurons prevented the detailed investigation of Parkinson's disease with regard to mitochondrial dysfunction. Both genetic and environmental factors are also associated with mitochondrial dysfunction and PD pathogenesis. The induction of PD by neurotoxins that inhibit mitochondrial complex I provide direct evidence linking mitochondrial dysfunction to PD. A decrease of mitochondrial complex I activity is observed in PD brain and in neurotoxin- or genetic factor-induced in vitro and in vivo models. Moreover, PINK1, Parkin, DJ-1 and LRRK2 mitochondrial PD gene products have important roles in mitophagy, a cellular process that clear damaged mitochondria. This review paper would discuss the evidence for the mitochondrial dysfunction and neuroinflammation in PD.
Collapse
Affiliation(s)
- Sugumar Mani
- Research and Development Centre, Bharathiar University, Coimbatore, Tamil Nadu, 641046, India
| | - Murugan Sevanan
- Department of Biotechnology, Karunya Institute of Technology and Sciences, Karunya Nagar, Coimbatore, Tamil Nadu, 641114, India.
| | | | - Sathiya Sekar
- Department of Biotechnology, Dr.M.G.R Educational Research Institute, Chennai, India
| |
Collapse
|
16
|
Chung YD, Liu TH, Liang YL, Lin CN, Hsu KF, Lee GB. An integrated microfluidic platform for detection of ovarian clear cell carcinoma mRNA biomarker FXYD2. LAB ON A CHIP 2021; 21:2625-2632. [PMID: 34013940 DOI: 10.1039/d1lc00177a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In this work we developed an integrated microfluidic system for automatically detecting the ovarian clear cell carcinoma (OCCC) biomarker FXYD2. Dealing with ascites from ovarian cancer patients, capture of cancer cells, isolation of messenger RNA, and quantitative reverse-transcription polymerase chain reaction were integrated into a single microfluidic chip and carried out on-chip automatically. OCCC is a subtype of ovarian cancer with a high mortality risk, and a high FXYD2 gene expression level was shown to be closely associated with OCCC. The lowest limit of quantification using a benchtop protocol of this system could be as low as 100 copies per sample. By normalizing the expression to a housekeeping gene, GAPDH, a simple cycle threshold ratio index could distinguish high FXYD2 expression cells from the low-expression ones. This developed platform may therefore facilitate future OCCC diagnosis and/or prognosis.
Collapse
Affiliation(s)
- Yi-Da Chung
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan.
| | - Ting-Hang Liu
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan.
| | - Yu-Ling Liang
- Department of Obstetrics and Gynecology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
| | - Chang-Ni Lin
- Department of Obstetrics and Gynecology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
| | - Keng-Fu Hsu
- Department of Obstetrics and Gynecology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 70403, Taiwan.
| | - Gwo-Bin Lee
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan. and Institute of NanoEngineering and MicroSystems, National Tsing Hua University, Hsinchu, Taiwan and Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
17
|
A New Direction in Microfluidics: Printed Porous Materials. MICROMACHINES 2021; 12:mi12060671. [PMID: 34201216 PMCID: PMC8229541 DOI: 10.3390/mi12060671] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 05/26/2021] [Accepted: 06/03/2021] [Indexed: 12/29/2022]
Abstract
In this work, the feasibility of a novel direction for microfluidics is studied by demonstrating a set of new methods to fabricate microfluidic systems. Similarly to microfluidic paper-based analytical devices, porous materials are being used. However, alternative porous materials and different printing methods are used here to give the material the necessary pattern to act as a microfluidic system. In this work, microfluidic systems were produced by the following three separate methods: (1) by curing a porous monolithic polymer sheet into a necessary pattern with photolithography, (2) by screen printing silica gel particles with gypsum, and (3) by dispensing silica gel particles with polyvinyl acetate binder using a modified 3D printer. Different parameters of the printed chips were determined (strength of the printed material, printing accuracy, printed material height, wetting characteristics, repeatability) to evaluate whether the printed chips were suitable for use in microfluidics. All three approaches were found to be suitable, and therefore the novel approach to microfluidics was successfully demonstrated.
Collapse
|
18
|
Dispas A, Emonts P, Fillet M. Microchip electrophoresis: A suitable analytical technique for pharmaceuticals quality control? A critical review. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116266] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
19
|
Lin B, Lei Y, Wang J, Zhu L, Wu Y, Zhang H, Wu L, Zhang P, Yang C. Microfluidic-Based Exosome Analysis for Liquid Biopsy. SMALL METHODS 2021; 5:e2001131. [PMID: 34927834 DOI: 10.1002/smtd.202001131] [Citation(s) in RCA: 78] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/29/2020] [Indexed: 06/14/2023]
Abstract
Liquid biopsy offers non-invasive and real-time molecular profiling of individual patients, and is thus considered a revolutionary technology in precision medicine. Exosomes have been acknowledged as significant biomarkers in liquid biopsy, as they play a central role in cell-cell communication and are closely related to the pathogenesis of most human malignancies. Nevertheless, in biofluids exosomes always co-exist with other particles, and the cargo components of exosomes are highly heterogeneous. Thus, the isolation and molecular characterization of exosomes are still technically challenging. Microfluidics technology effectively addresses this challenge by virtue of its inherent advantages, such as precise manipulation of fluids, low consumption of samples and reagents, and a high level of integration. Recent advances in microfluidics allow in situ exosome capture and molecular detection with unprecedented selectivity and sensitivity. In this review, the state-of-the-art developments in microfluidics-based exosome research, including exosome isolation approaches and molecular detection strategies, with highlights of the characterization of exosomal biomarkers in cancer liquid biopsy is summarized. The major challenges are also discussed and some perspectives for the future directions of exosome-based liquid biopsy in microfluidic systems are presented.
Collapse
Affiliation(s)
- Bingqian Lin
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
| | - Yanmei Lei
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China
| | - Junxia Wang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
| | - Lin Zhu
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
| | - Yuqi Wu
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
| | - Huimin Zhang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
| | - Lingling Wu
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China
| | - Peng Zhang
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China
| | - Chaoyong Yang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China
| |
Collapse
|
20
|
Single-use microfluidic device for purification and concentration of environmental DNA from river water. Talanta 2021; 226:122109. [PMID: 33676665 DOI: 10.1016/j.talanta.2021.122109] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 01/04/2021] [Accepted: 01/09/2021] [Indexed: 12/29/2022]
Abstract
Purification and concentration of DNA is a critical step on DNA-based analysis, which should ensure efficient DNA isolation and effective removal of contaminants that may interfere with downstream DNA amplification. Complexity of samples, minute content of target analyte, or high DNA fragmentation greatly entangles the success of this step. To overcome this issue, we designed and fabricated a novel miniaturized disposable device for a highly efficient DNA purification. The microfluidic device showed binding efficiency and elution yield of 90.1% and 86.7%, respectively. Moreover, the effect of DNA fragmentation, a parameter that has not been previously addressed, showed a great impact in the recovery step. The microfluidic system integrated micropillars with chitosan being used as the solid-phase for a pH-dependent DNA capture and release. We have showed the potential of the device in the successful purification of environmental DNA (eDNA) from river water samples contaminated with Dreissena polymorpha, an invasive alien species responsible for unquestionable economic and environmental consequences in river water basins. Additionally, the device was also able to concentrate the DNA extract from highly diluted samples, showing promising results for the early detection of such invasive species, which may allow prompt measures for a more efficient control in affected areas. Suitability for integration with downstream DNA analysis was also demonstrated through qPCR analysis of the samples purified with the microfluidic device, allowing detection of the target species even if highly diluted.
Collapse
|
21
|
Berlanda SF, Breitfeld M, Dietsche CL, Dittrich PS. Recent Advances in Microfluidic Technology for Bioanalysis and Diagnostics. Anal Chem 2020; 93:311-331. [DOI: 10.1021/acs.analchem.0c04366] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Simon F. Berlanda
- Department of Biosystems Science and Engineering, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Maximilian Breitfeld
- Department of Biosystems Science and Engineering, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Claudius L. Dietsche
- Department of Biosystems Science and Engineering, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Petra S. Dittrich
- Department of Biosystems Science and Engineering, ETH Zurich, CH-8093 Zurich, Switzerland
| |
Collapse
|
22
|
Rodriguez-Mateos P, Azevedo NF, Almeida C, Pamme N. FISH and chips: a review of microfluidic platforms for FISH analysis. Med Microbiol Immunol 2020; 209:373-391. [PMID: 31965296 PMCID: PMC7248050 DOI: 10.1007/s00430-019-00654-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 12/19/2019] [Indexed: 12/12/2022]
Abstract
Fluorescence in situ hybridization (FISH) allows visualization of specific nucleic acid sequences within an intact cell or a tissue section. It is based on molecular recognition between a fluorescently labeled probe that penetrates the cell membrane of a fixed but intact sample and hybridizes to a nucleic acid sequence of interest within the cell, rendering a measurable signal. FISH has been applied to, for example, gene mapping, diagnosis of chromosomal aberrations and identification of pathogens in complex samples as well as detailed studies of cellular structure and function. However, FISH protocols are complex, they comprise of many fixation, incubation and washing steps involving a range of solvents and temperatures and are, thus, generally time consuming and labor intensive. The complexity of the process, the relatively high-priced fluorescent probes and the fairly high-end microscopy needed for readout render the whole process costly and have limited wider uptake of this powerful technique. In recent years, there have been attempts to transfer FISH assay protocols onto microfluidic lab-on-a-chip platforms, which reduces the required amount of sample and reagents, shortens incubation times and, thus, time to complete the protocol, and finally has the potential for automating the process. Here, we review the wide variety of approaches for lab-on-chip-based FISH that have been demonstrated at proof-of-concept stage, ranging from FISH analysis of immobilized cell layers, and cells trapped in arrays, to FISH on tissue slices. Some researchers have aimed to develop simple devices that interface with existing equipment and workflows, whilst others have aimed to integrate the entire FISH protocol into a fully autonomous FISH on-chip system. Whilst the technical possibilities for FISH on-chip are clearly demonstrated, only a small number of approaches have so far been converted into off-the-shelf products for wider use beyond the research laboratory.
Collapse
Affiliation(s)
- Pablo Rodriguez-Mateos
- Department of Chemistry and Biochemistry, University of Hull, Cottingham Road, Hull, HU6 7RX, UK
| | - Nuno Filipe Azevedo
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Department of Chemical Engineering, Faculty of Engineering of University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465, Porto, Portugal
- Biomode SA, Av. Mestre José Veiga, 4715-330, Braga, Portugal
| | - Carina Almeida
- Biomode SA, Av. Mestre José Veiga, 4715-330, Braga, Portugal
- INIAV, I.P.-National Institute for Agricultural and Veterinary Research, Rua dos Lagidos, Lugar da Madalena, Vairão, 4485-655, Vila Do Conde, Portugal
- CEB-Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal
| | - Nicole Pamme
- Department of Chemistry and Biochemistry, University of Hull, Cottingham Road, Hull, HU6 7RX, UK.
| |
Collapse
|
23
|
Soum V, Park S, Brilian AI, Choi JY, Lee Y, Kim W, Kwon OS, Shin K. Quantitatively controllable fluid flows with ballpoint-pen-printed patterns for programmable photo-paper-based microfluidic devices. LAB ON A CHIP 2020; 20:1601-1611. [PMID: 32249884 DOI: 10.1039/d0lc00115e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Regulating the fluid flow in microfluidic devices enables a wide range of assay protocols for analytical applications. A programmable, photo-paper-based microfluidic device fabricated by using a method of cutting and laminating, followed by printing, is reported. The flow distance of fluid in the photo-paper-based channel was linearly proportional to time. By printing silver nanoparticle (AgNP) and poly[4,5-difluoro-2,2-bis(trifluoromethyl)-1,3-dioxole-co-tetrafluoroethylene] (PTFE) patterns on the surface of a photo-paper-based channel, we were able to either increase or decrease the fluid flow in the fabricated microfluidic devices, while maintaining the linearity in the flow distance-time relation. In comparison to the speed of fluid flow in a pristine channel, by using hydrophilic AgNP patterns, we were able to increase the speed in the channel by up to 15 times while we were able to slow the speed by a factor of 3 when using hydrophobic PTFE dots. We then further demonstrated a single-step protocol for detecting glucose and a multi-step protocol for detecting methyl paraoxon (MPO) with our methods in photo-paper-based microfluidic devices. This approach can lead to improved fluid handling techniques to achieve a wide range of complex, but programmable, assays without the need for any additional auxiliary devices for automated operation.
Collapse
Affiliation(s)
- Veasna Soum
- Department of Chemistry and Institute of Biological Interfaces, Sogang University, Seoul 04107, Korea.
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Raza W, Hossain S, Kim KY. A Review of Passive Micromixers with a Comparative Analysis. MICROMACHINES 2020; 11:mi11050455. [PMID: 32349452 PMCID: PMC7281436 DOI: 10.3390/mi11050455] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 04/24/2020] [Accepted: 04/24/2020] [Indexed: 01/05/2023]
Abstract
A wide range of existing passive micromixers are reviewed, and quantitative analyses of ten typical passive micromixers were performed to compare their mixing indices, pressure drops, and mixing costs under the same axial length and flow conditions across a wide Reynolds number range of 0.01–120. The tested micromixers were selected from five types of micromixer designs. The analyses of flow and mixing were performed using continuity, Navier-Stokes and convection-diffusion equations. The results of the comparative analysis were presented for three different Reynolds number ranges: low-Re (Re ≤ 1), intermediate-Re (1 < Re ≤ 40), and high-Re (Re > 40) ranges, where the mixing mechanisms are different. The results show a two-dimensional micromixer of Tesla structure is recommended in the intermediate- and high-Re ranges, while two three-dimensional micromixers with two layers are recommended in the low-Re range due to their excellent mixing performance.
Collapse
Affiliation(s)
| | | | - Kwang-Yong Kim
- Correspondence: ; Tel.: +82-32-872-3096; Fax: +82-32-868-1716
| |
Collapse
|
25
|
Low-cost Point-of-Care Biosensors Using Common Electronic Components as Transducers. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4104-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
26
|
Hossain S, Fuwad A, Kim KY, Jeon TJ, Kim SM. Investigation of Mixing Performance of Two-Dimensional Micromixer Using Tesla Structures with Different Shapes of Obstacles. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.9b06741] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Shakhawat Hossain
- Department of Unmanned Vehicle Engineering, Sejong University, Seoul 05006, Korea
| | - Ahmed Fuwad
- Department of Mechanical Engineering, Inha University, Incheon 22212, Korea
| | - Kwang-Yong Kim
- Department of Mechanical Engineering, Inha University, Incheon 22212, Korea
| | - Tae-Joon Jeon
- Department of Biological Engineering, Inha University, Incheon 22212, Korea
| | - Sun Min Kim
- Department of Mechanical Engineering, Inha University, Incheon 22212, Korea
| |
Collapse
|
27
|
Sola D, Cases R. High-Repetition-Rate Femtosecond Laser Processing of Acrylic Intra-Ocular Lenses. Polymers (Basel) 2020; 12:polym12010242. [PMID: 31968562 PMCID: PMC7023549 DOI: 10.3390/polym12010242] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 01/15/2020] [Accepted: 01/16/2020] [Indexed: 02/07/2023] Open
Abstract
The study of laser processing of acrylic intra-ocular lenses (IOL) by using femtosecond laser pulses delivered at high-repetition rate is presented in this work. An ultra-compact air-cooled femtosecond diode laser (HighQ2-SHG, Spectra-Physics) delivering 250 fs laser pulses at the fixed wavelength of 520 nm with a repetition rate of 63 MHz was used to process the samples. Laser inscription of linear periodic patterns on the surface and inside the acrylic substrates was studied as a function of the processing parameters as well as the optical absorption characteristics of the sample. Scanning Electron Microscopy (SEM) Energy Dispersive X-ray Spectroscopy (EDX), and micro-Raman Spectroscopy were used to evaluate the compositional and microstructural changes induced by the laser radiation in the processed areas. Diffractive characterization was used to assess 1st-order efficiency and the refractive index change.
Collapse
Affiliation(s)
- Daniel Sola
- Institut für Fertigungstechnik, Technische Universität Dresden, 01069 Dresden, Germany
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus Espinardo, 30100 Murcia, Spain
- Correspondence:
| | - Rafael Cases
- Departamento de Física de la Materia Condensada, Universidad de Zaragoza, 50009 Zaragoza, Spain;
| |
Collapse
|
28
|
Geng Z, Gu Y, Li S, Lin B, Liu P. A Fully Integrated In Vitro Diagnostic Microsystem for Pathogen Detection Developed Using a "3D Extensible" Microfluidic Design Paradigm. MICROMACHINES 2019; 10:E873. [PMID: 31842384 PMCID: PMC6953088 DOI: 10.3390/mi10120873] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 12/04/2019] [Accepted: 12/10/2019] [Indexed: 01/09/2023]
Abstract
Microfluidics is facing critical challenges in the quest of miniaturizing, integrating, and automating in vitro diagnostics, including the increasing complexity of assays, the gap between the macroscale world and the microscale devices, and the diverse throughput demands in various clinical settings. Here, a "3D extensible" microfluidic design paradigm that consists of a set of basic structures and unit operations was developed for constructing any application-specific assay. Four basic structures-check valve (in), check valve (out), double-check valve (in and out), and on-off valve-were designed to mimic basic acts in biochemical assays. By combining these structures linearly, a series of unit operations can be readily formed. We then proposed a "3D extensible" architecture to fulfill the needs of the function integration, the adaptive "world-to-chip" interface, and the adjustable throughput in the X, Y, and Z directions, respectively. To verify this design paradigm, we developed a fully integrated loop-mediated isothermal amplification microsystem that can directly accept swab samples and detect Chlamydia trachomatis automatically with a sensitivity one order higher than that of the conventional kit. This demonstration validated the feasibility of using this paradigm to develop integrated and automated microsystems in a less risky and more consistent manner.
Collapse
Affiliation(s)
- Zhi Geng
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Z.G.); (Y.G.); (S.L.); (B.L.)
| | - Yin Gu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Z.G.); (Y.G.); (S.L.); (B.L.)
- FengteBio Corporation, Beijing 100079, China
| | - Shanglin Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Z.G.); (Y.G.); (S.L.); (B.L.)
- FengteBio Corporation, Beijing 100079, China
| | - Baobao Lin
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Z.G.); (Y.G.); (S.L.); (B.L.)
| | - Peng Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Z.G.); (Y.G.); (S.L.); (B.L.)
| |
Collapse
|
29
|
Funano S, Tanaka N, Tanaka Y. User‐friendly cell patterning methods using a polydimethylsiloxane mold with microchannels. Dev Growth Differ 2019; 62:167-176. [DOI: 10.1111/dgd.12637] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 10/17/2019] [Accepted: 10/22/2019] [Indexed: 12/11/2022]
Affiliation(s)
| | | | - Yo Tanaka
- Center for Biosystems Dynamics Research RIKEN Osaka Japan
| |
Collapse
|
30
|
Yu N, Liu Y, Wang S, Tang X, Ge P, Nan J, Zhang J, Yang B. Pressure-controlled microfluidic sub-picoliter ultramicro-volume syringes based on integrated micro-nanostructure arrays. LAB ON A CHIP 2019; 19:3368-3374. [PMID: 31549119 DOI: 10.1039/c9lc00730j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Ultramicro-volume syringes were fabricated by integrating micro-nanostructure arrays in microchannels for quantitatively dispensing sub-picoliter volumes of liquids. Using this system, liquids were dispensed in volume increments as low as 0.5 pL with 96% accuracy. Specifically, the controllable synthesis of nanocrystals was achieved using a lab-on-chip platform that was integrated with the syringes.
Collapse
Affiliation(s)
- Nianzuo Yu
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, 130012, P. R. China.
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Piendl SK, Raddatz CR, Hartner NT, Thoben C, Warias R, Zimmermann S, Belder D. 2D in Seconds: Coupling of Chip-HPLC with Ion Mobility Spectrometry. Anal Chem 2019; 91:7613-7620. [DOI: 10.1021/acs.analchem.9b00302] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian-Robert Raddatz
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Nora T. Hartner
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian Thoben
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Rico Warias
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
32
|
Shandilya R, Bhargava A, Bunkar N, Tiwari R, Goryacheva IY, Mishra PK. Nanobiosensors: Point-of-care approaches for cancer diagnostics. Biosens Bioelectron 2019; 130:147-165. [PMID: 30735948 DOI: 10.1016/j.bios.2019.01.034] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 12/21/2018] [Accepted: 01/12/2019] [Indexed: 12/24/2022]
|
33
|
Jiao L, Chen R, Zhu X, Liao Q, Wang H, An L, Zhu J, He X, Feng H. Highly Flexible and Ultraprecise Manipulation of Light-Levitated Femtoliter/Picoliter Droplets. J Phys Chem Lett 2019; 10:1068-1077. [PMID: 30758967 DOI: 10.1021/acs.jpclett.8b03699] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Ultraprecise manipulation of the droplets at the microscale is a promising paradigm for broad implications in reagent transport and element analysis, but the existing strategies still suffer from cross-contamination or the miscellaneous auxiliaries. Inspired by the levitation, we develop a method for excellently manipulating levitated femtoliter/picoliter droplets by a single focused laser. We show that the unique light-induced vapor flow in association with the interface morphology is responsible for creation and manipulation of levitated droplets. In particular, we demonstrate that the levitated droplets formed by this light method show extraordinary motility. The highly accurate two-dimensional labyrinth movement of the levitated droplets with designed trajectories above the free surface is easily realized by scanning the light. These results demonstrate that a single focused light can function as an "optical baton" to enable us to construct a wide variety of the long-sought precise manipulation systems for bioassays, pharmacy, and chemosynthesis.
Collapse
Affiliation(s)
- Long Jiao
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| | - Rong Chen
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| | - Xun Zhu
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| | - Qiang Liao
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| | - Hong Wang
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| | - Liang An
- Department of Mechanical Engineering , The Hong Kong Polytechnic University , Hong Kong , China
| | - Jie Zhu
- Department of Mechanical Engineering , The Hong Kong Polytechnic University , Hong Kong , China
| | - Xuefeng He
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| | - Hao Feng
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems , Chongqing University , Ministry of Education, Chongqing 400030 , China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering , Chongqing University , Chongqing 400030 , China
| |
Collapse
|
34
|
Biswas GC, Rana MM, Kazuhiro T, Suzuki H. A simple micropump based on a freeze-dried superabsorbent polymer for multiplex solution processing in disposable devices. ROYAL SOCIETY OPEN SCIENCE 2019; 6:182213. [PMID: 31032056 PMCID: PMC6458371 DOI: 10.1098/rsos.182213] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 02/27/2019] [Indexed: 06/09/2023]
Abstract
We describe a simple micropump for disposable microfluidic devices. The pump is constructed using a freeze-dried disc of a superabsorbent polymer (SAP). The disc absorbs a solution in a flow channel and swells upward in a pumping chamber. Despite the simple structure of this device, the rate of absorption remains constant and can be adjusted by changing the composition of the SAP, its size, the dimensions of the flow channel and the medium to be absorbed. The pumping action can be initiated by applying an electrical signal using a switchable hydrophobic valve. The integrated approach of the SAP pump and switchable valve could facilitate the automatic processing of many solutions required for bioassay.
Collapse
Affiliation(s)
- Gokul Chandra Biswas
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Md. Mohosin Rana
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Takekoshi Kazuhiro
- Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8675, Japan
| | - Hiroaki Suzuki
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| |
Collapse
|
35
|
Holmes J, Pathirathna P, Hashemi P. Novel frontiers in voltammetric trace metal analysis: Towards real time, on-site, in situ measurements. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.11.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
36
|
Strzelak K, Koncki R. A remote-controlled immunochemical system for nephelometric detection of human serum transferrin. Biosens Bioelectron 2019; 127:31-37. [DOI: 10.1016/j.bios.2018.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
37
|
Buyuktuncel E. Microchip Electrophoresis and Bioanalytical Applications. CURR PHARM ANAL 2019. [DOI: 10.2174/1573412914666180831100533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Microanalytical systems have aroused great interest because they can analyze extremely
small sample volumes, improve the rate and throughput of chemical and biochemical analysis in a way
that reduces costs. Microchip Electrophoresis (ME) represents an effective separation technique to perform
quick analytical separations of complex samples. It offers high resolution and significant peak
capacity. ME is used in many areas, including biology, chemistry, engineering, and medicine. It is established
the same working principles as Capillary Electrophoresis (CE). It is possible to perform electrophoresis
in a more direct and convenient way in a microchip. Since the electric field is the driving
force of the electrodes, there is no need for high pressure as in chromatography. The amount of the voltage
that is applied in some electrophoresis modes, e.g. Micelle Electrokinetic Chromatography (MEKC)
and Capillary Zone Electrophoresis (CZE), mainly determines separation efficiency. Therefore, it is
possible to apply a higher electric field along a considerably shorter separation channel, hence it is possible
to carry out ME much quicker.
Collapse
Affiliation(s)
- Ebru Buyuktuncel
- Faculty of Pharmacy, Department of Analytical Chemistry, Inonu University, 44280, Malatya, Turkey
| |
Collapse
|
38
|
Bressan LP, de Jesus DP, Gunasekara DB, Lunte SM, da Silva JAF. Microchip Electrophoresis Containing Electrodes for Integrated Electrochemical Detection. Methods Mol Biol 2019; 1906:79-85. [PMID: 30488386 DOI: 10.1007/978-1-4939-8964-5_5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Microchip electrophoresis is a versatile separation technique. Electrochemical detection is suitable to apply to microdevices due to its easy integration to the fabrication process and good sensitivity and selectivity. Here we describe the procedures to prepare Pt band electrodes deposited on glass to couple to polydimethylsiloxane (PDMS) microchips aiming the separation and detection of nitrite using an isolated potentiostat.
Collapse
Affiliation(s)
| | | | | | - Susan Marie Lunte
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | | |
Collapse
|
39
|
Controlled Release and Separation of Magnetic Nanoparticles Using Microfluidics by Varying Bifurcation Angle of Microchannels. J Inorg Organomet Polym Mater 2018. [DOI: 10.1007/s10904-018-1000-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
40
|
Gong Y, Fan N, Yang X, Peng B, Jiang H. New advances in microfluidic flow cytometry. Electrophoresis 2018; 40:1212-1229. [PMID: 30242856 DOI: 10.1002/elps.201800298] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 09/07/2018] [Accepted: 09/15/2018] [Indexed: 01/22/2023]
Abstract
In recent years, researchers are paying the increasing attention to the development of portable microfluidic diagnostic devices including microfluidic flow cytometry for the point-of-care testing. Microfluidic flow cytometry, where microfluidics and flow cytometry work together to realize novel functionalities on the microchip, provides a powerful tool for measuring the multiple characteristics of biological samples. The development of a portable, low-cost, and compact flow cytometer can benefit the health care in underserved areas such as Africa or Asia. In this article, we review recent advancements of microfluidics including sample pumping, focusing and sorting, novel detection approaches, and data analysis in the field of flow cytometry. The challenge of microfluidic flow cytometry is also examined briefly.
Collapse
Affiliation(s)
- Yanli Gong
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Na Fan
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Xu Yang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| |
Collapse
|
41
|
Alnaimat F, Dagher S, Mathew B, Hilal‐Alnqbi A, Khashan S. Microfluidics Based Magnetophoresis: A Review. CHEM REC 2018; 18:1596-1612. [DOI: 10.1002/tcr.201800018] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 05/24/2018] [Indexed: 02/01/2023]
Affiliation(s)
- Fadi Alnaimat
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
| | - Sawsan Dagher
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
| | - Bobby Mathew
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
| | - Ali Hilal‐Alnqbi
- Mechanical Engineering DepartmentCollege of EngineeringUAE University Al Ain Abu Dhabi UAE
- Abu Dhabi Polytechnic Abu Dhabi UAE
| | - Saud Khashan
- Mechanical Engineering DepartmentJordan University of Science and Technology Irbid Jordan
| |
Collapse
|
42
|
Lab-on-a-chip platforms for quantification of multicellular interactions in bone remodeling. Exp Cell Res 2018; 365:106-118. [PMID: 29499205 DOI: 10.1016/j.yexcr.2018.02.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 02/22/2018] [Accepted: 02/23/2018] [Indexed: 01/09/2023]
Abstract
Researchers have been using lab-on-a-chip systems to isolate factors for study, simulate laboratory analysis and model cellular, tissue and organ level processes. The technology is increasing rapidly, but the bone field has been slow to keep pace. Novel models are needed that have the power and flexibility to investigate the elegant and synchronous multicellular interactions that occur in normal bone turnover and in disease states in which remodeling is implicated. By removing temporal and spatial limitations and enabling quantification of functional outcomes, the platforms should provide unique environments that are more biomimetic than single cell type systems while minimizing complex systemic effects of in vivo models. This manuscript details the development and characterization of lab-on-a-chip platforms for stimulating osteocytes and quantifying bone remodeling. Our platforms provide the foundation for a model that can be used to investigate remodeling interactions as a whole or as a standard mechanotransduction tool by which isolated activity can be quantified as a function of load.
Collapse
|
43
|
Shiba K, Ogawa M. Precise Synthesis of Well-Defined Inorganic-Organic Hybrid Particles. CHEM REC 2018; 18:950-968. [PMID: 29320612 DOI: 10.1002/tcr.201700077] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 12/22/2017] [Indexed: 11/07/2022]
Abstract
Synthesis of hybrid particles toward precisely designed hierarchical nanoarchitectures is summarized. In order to satisfy the demands for a variety of materials' performances, the selection of materials, composition and synthesis is carefully done. Flow reactors are one of the useful synthetic means to prepare hybrid materials, especially those with hierarchically and precisely designed multi-components hybrid particles, owing to the efficient mixing and heat exchange in the reactor as well as its connectable (both parallel and sequential) feature. In this review article, after the summary of the preparation of hybrids based on oxides and organics through conventional batch reactors, the application of flow reactors to the preparation of various hybrid particles is introduced to highlight the present status and future possibility of the flow reactor synthesis.
Collapse
Affiliation(s)
- Kota Shiba
- International Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki, 305-0044, Japan
| | - Makoto Ogawa
- School of Energy Science and Engineering, Vidyasirimedhi Institute of Science and Technology, 555 Moo 1 Tumbol Payupnai, Amphoe Wangchan, Rayong, 21210, Thailand
| |
Collapse
|
44
|
Wang C, Cao J, Zhou Y, Xia XH. On-chip microfluidic generation of monodisperse bubbles for liquid interfacial tension measurement. Talanta 2018; 176:646-651. [DOI: 10.1016/j.talanta.2017.08.084] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2017] [Revised: 08/20/2017] [Accepted: 08/27/2017] [Indexed: 11/29/2022]
|
45
|
Wiederoder MS, Kendall E, Han JH, Ulrich R, DeVoe DL. Flow-through microfluidic immunosensors with refractive index-matched silica monoliths as volumetric optical detection elements. SENSORS AND ACTUATORS. B, CHEMICAL 2018; 254:878-886. [PMID: 29225421 PMCID: PMC5716804 DOI: 10.1016/j.snb.2017.07.137] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A sensitive and rapid absorbance based immunosensor that utilizes ex situ functionalized porous silica monoliths as volumetric optical detection elements is demonstrated in this study. The porous monolith structure facilitates high capture probe density and short diffusion length scales, enabling sensitive and rapid assays. Silica monoliths, synthesized and functionalized with immunocapture probes off-chip before integration into a sealed thermoplastic microfluidic device, serve to capture target antigens during perfusion through the porous structure. Gold nanoparticle immunoconjugates are combined with silver enhancement to create microscale silver clusters, followed by perfusion of an aqueous sucrose solution to limit light scattering and enhance optical signal. Using this approach, detection limits as low as 1 ng/mL are achieved for a sandwich assay, with a dynamic range of at least 4 logs. The results confirm that the combination of on-chip index matching with functionalized porous silica monoliths can enables simple and practical flow-through immunoassays for the sensitive and rapid detection of target antigens.
Collapse
Affiliation(s)
- M. S. Wiederoder
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, USA
| | - E.L. Kendall
- Department of Mechanical Engineering, University of Maryland, College Park, Maryland, USA
| | - J.-H. Han
- Molecular and Translational Sciences, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), Frederick, Maryland, USA
| | - R.G. Ulrich
- Molecular and Translational Sciences, United States Army Medical Research Institute of Infectious Diseases (USAMRIID), Frederick, Maryland, USA
| | - D. L. DeVoe
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, USA
- Department of Mechanical Engineering, University of Maryland, College Park, Maryland, USA
| |
Collapse
|
46
|
Sibbitts J, Sellens KA, Jia S, Klasner SA, Culbertson CT. Cellular Analysis Using Microfluidics. Anal Chem 2017; 90:65-85. [DOI: 10.1021/acs.analchem.7b04519] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Jay Sibbitts
- Department
of Chemistry, Kansas State University, Manhattan, Kansas 66506, United States
| | - Kathleen A. Sellens
- Department
of Chemistry, Kansas State University, Manhattan, Kansas 66506, United States
| | - Shu Jia
- Department
of Chemistry, Kansas State University, Manhattan, Kansas 66506, United States
| | - Scott A. Klasner
- 12966
South
State Highway 94, Marthasville, Missouri 63357, United States
| | | |
Collapse
|
47
|
Dossi N, Petrazzi S, Toniolo R, Tubaro F, Terzi F, Piccin E, Svigelj R, Bontempelli G. Digitally Controlled Procedure for Assembling Fully Drawn Paper-Based Electroanalytical Platforms. Anal Chem 2017; 89:10454-10460. [DOI: 10.1021/acs.analchem.7b02521] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Nicolò Dossi
- Department
of Agrifood, Environmental and Animal Science, University of Udine, via Cotonificio 108, I-33100 Udine, Italy
| | - Stefano Petrazzi
- Department
of Agrifood, Environmental and Animal Science, University of Udine, via Cotonificio 108, I-33100 Udine, Italy
| | - Rosanna Toniolo
- Department
of Agrifood, Environmental and Animal Science, University of Udine, via Cotonificio 108, I-33100 Udine, Italy
| | - Franco Tubaro
- Department
of Agrifood, Environmental and Animal Science, University of Udine, via Cotonificio 108, I-33100 Udine, Italy
| | - Fabio Terzi
- Department
of Chemical and Geological Science, University of Modena and Reggio Emilia, via Campi 183, I-41125 Modena, Italy
| | - Evandro Piccin
- Department
of Chemistry, Federal University of Minas Gerais, 31270-901 Belo Horizonte, Brazil
| | - Rossella Svigelj
- Department
of Agrifood, Environmental and Animal Science, University of Udine, via Cotonificio 108, I-33100 Udine, Italy
| | - Gino Bontempelli
- Department
of Agrifood, Environmental and Animal Science, University of Udine, via Cotonificio 108, I-33100 Udine, Italy
| |
Collapse
|
48
|
Gong MM, Sinton D. Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application. Chem Rev 2017. [PMID: 28627178 DOI: 10.1021/acs.chemrev.7b00024] [Citation(s) in RCA: 334] [Impact Index Per Article: 41.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Infectious diseases are a major global health issue. Diagnosis is a critical first step in effectively managing their spread. Paper-based microfluidic diagnostics first emerged in 2007 as a low-cost alternative to conventional laboratory testing, with the goal of improving accessibility to medical diagnostics in developing countries. In this review, we examine the advances in paper-based microfluidic diagnostics for medical diagnosis in the context of global health from 2007 to 2016. The theory of fluid transport in paper is first presented. The next section examines the strategies that have been employed to control fluid and analyte transport in paper-based assays. Tasks such as mixing, timing, and sequential fluid delivery have been achieved in paper and have enabled analytical capabilities comparable to those of conventional laboratory methods. The following section examines paper-based sample processing and analysis. The most impactful advancement here has been the translation of nucleic acid analysis to a paper-based format. Smartphone-based analysis is another exciting development with potential for wide dissemination. The last core section of the review highlights emerging health applications, such as male fertility testing and wearable diagnostics. We conclude the review with the future outlook, remaining challenges, and emerging opportunities.
Collapse
Affiliation(s)
- Max M Gong
- Department of Mechanical and Industrial Engineering, University of Toronto , 5 King's College Road, Toronto, Ontario, Canada M5S 3G8.,Department of Biomedical Engineering, Wisconsin Institutes for Medical Research, University of Wisconsin-Madison , 1111 Highland Avenue, Madison, Wisconsin 53705, United States
| | - David Sinton
- Department of Mechanical and Industrial Engineering, University of Toronto , 5 King's College Road, Toronto, Ontario, Canada M5S 3G8
| |
Collapse
|
49
|
Beulig RJ, Warias R, Heiland JJ, Ohla S, Zeitler K, Belder D. A droplet-chip/mass spectrometry approach to study organic synthesis at nanoliter scale. LAB ON A CHIP 2017; 17:1996-2002. [PMID: 28513728 DOI: 10.1039/c7lc00313g] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A droplet-based microfluidic device with seamless hyphenation to electrospray mass spectrometry was developed to rapidly investigate organic reactions in segmented flow providing a versatile tool for drug development. A chip-MS interface with an integrated counterelectrode allowed for a flexible positioning of the chip-emitter in front of the MS orifice as well as an independent adjustment of the electrospray potentials. This was necessary to avoid contamination of the mass spectrometer as well as sample overloading due to the high analyte concentrations. The device was exemplarily applied to study the scope of an amino-catalyzed domino reaction with low picomole amount of catalyst in individual nanoliter sized droplets.
Collapse
Affiliation(s)
- R J Beulig
- Institute for Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany.
| | | | | | | | | | | |
Collapse
|
50
|
Linz TH, Hampton Henley W, Michael Ramsey J. Photobleaching kinetics-based bead encoding for multiplexed bioassays. LAB ON A CHIP 2017; 17:1076-1082. [PMID: 28205650 DOI: 10.1039/c6lc01415a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Multiplexing bead-based bioassays requires that each type of microsphere be uniquely encoded to distinguish one type from another. Microspheres are typically encoded using fluorescent dyes with different spectral properties and varying concentrations. However practical limits exist on the number of dyes that can be spectrally resolved or the number of distinguishable intensity levels with each dye. To expand the number of encoding levels, a novel method was developed that incorporates photobleaching kinetics into bead decoding, unlocking additional multiplexing levels unattainable by conventional decoding methods. To demonstrate this technique, beads were encoded with two dyes having overlapping fluorescence excitation and emission wavelengths but different photostabilities. All beads initially exhibited similar fluorescence intensities; however, following appropriate photoexposure, the less photostable dye had reduced emission intensity due to photobleaching. By comparing the original fluorescence emission intensity to that obtained after photobleaching, multiple different populations could be reliably identified. Using only a single excitation/emission band, two different initial intensity levels were optimized to produce six uniquely identifiable bead populations whereas only two could have been achieved with conventional decoding methods. Incorporation of this encoding strategy into bead-based microwell array assays significantly increases the number of encoding levels available for multiplexed assays without increasing the complexity of the imaging instrumentation.
Collapse
Affiliation(s)
- Thomas H Linz
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA.
| | - W Hampton Henley
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA.
| | - J Michael Ramsey
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA.
| |
Collapse
|