1
|
Gupta S, Mishra D, DasMahapatra S, Singh K. Integration of silicon nanostructures for health and energy applications using MACE: a cost-effective process. NANOTECHNOLOGY 2024; 35:423001. [PMID: 38897177 DOI: 10.1088/1361-6528/ad59ad] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 06/19/2024] [Indexed: 06/21/2024]
Abstract
Silicon in its nanoscale range offers a versatile scope in biomedical, photovoltaic, and solar cell applications. Due to its compatibility in integration with complex molecules owing to changes in charge density of as-fabricated Silicon Nanostructures (SiNSs) to realize label-free and real-time detection of certain biological and chemical species with certain biomolecules, it can be exploited as an indicator for ultra-sensitive and cost-effective biosensing applications in disease diagnosis. The morphological changes of SiNSs modified receptors (PNA, DNA, etc) have huge future scope in optimized sensitivity (due to conductance variations of SiNSs) of target biomolecules in health care applications. Further, due to the unique optical and electrical properties of SiNSs realized using the chemical etching technique, they can be used as an indicator for photovoltaic and solar cell applications. In this work, emphasis is given on different critical parameters that control the fabrication morphologies of SiNSs using metal-assisted chemical etching technique (MACE) and its corresponding fabrication mechanisms focusing on numerous applications in energy storage and health care domains. The evolution of MACE as a low-cost, easy process control, reproducibility, and convenient fabrication mechanism makes it a highly reliable-process friendly technique employed in photovoltaic, energy storage, and biomedical fields. Analysis of the experimental fabrication to obtain high aspect ratio SiNSs was carried out using iMAGEJ software to understand the role of surface-to-volume ratio in effective bacterial interfacing. Also, the role of silicon nanomaterials has been discussed as effective anti-bacterial surfaces due to the presence of silver investigated in the post-fabrication energy dispersive x-ray spectroscopy analysis using MACE.
Collapse
Affiliation(s)
- Shubham Gupta
- FlexMEMS Research Centre (FMRC), Manipal University Jaipur, Jaipur, Rajasthan 303007, India
- Department of Electronics & Communication Engineering, Manipal University Jaipur, Jaipur, Rajasthan 303007, India
| | - Dhaneshwar Mishra
- Multiscale Simulation Research Center (MSRC), Manipal University Jaipur, Jaipur, Rajasthan 303007, India
- Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, Rajasthan 303007, India
| | - Suddhendu DasMahapatra
- FlexMEMS Research Centre (FMRC), Manipal University Jaipur, Jaipur, Rajasthan 303007, India
- Department of Electronics & Communication Engineering, Manipal University Jaipur, Jaipur, Rajasthan 303007, India
| | - Kulwant Singh
- FlexMEMS Research Centre (FMRC), Manipal University Jaipur, Jaipur, Rajasthan 303007, India
- Department of Electronics & Communication Engineering, Manipal University Jaipur, Jaipur, Rajasthan 303007, India
- Skill Faculty of Engineering & Technology, Shri Vishwakarma Skill University, Palwal 121102, Haryana, India
| |
Collapse
|
2
|
Singh N, Kaushik A, Ghori I, Rai P, Dong L, Sharma A, Malhotra BD, John R. Electrochemical and Plasmonic Detection of Myocardial Infarction Using Microfluidic Biochip Incorporated with Mesoporous Nanoscaffolds. ACS APPLIED MATERIALS & INTERFACES 2024; 16:32794-32811. [PMID: 38860871 DOI: 10.1021/acsami.4c01398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
This paper reports a microfluidic device for the electrochemical and plasmonic detection of cardiac myoglobin (cMb) and cardiac troponin I (cTnI) with noticeable limits of detection (LoD) as low as a few picograms per milliliter (pg/mL) ranges, achieved in a short detection time. The device features two working electrodes, each with a mesoporous Ni3V2O8 nanoscaffold grafted with reduced graphene oxide (rGO) that improves the interaction of diffusing analyte molecules with the sensing surface by providing a high surface area and reaction kinetics. Electrochemical studies reveal sensitivities as high as 9.68 μA ng/mL and a LoD of 2.0 pg/mL for cTnI, and 8.98 μA ng/mL and 4.7 pg/mL for cMb. Additionally, the surface plasmon resonance (SPR) studies demonstrate a low-level LoD of 8.8 pg/mL for cMb and 7.3 pg/mL for cTnI. The dual-modality sensor enables dynamic tracking of kinetic antigen-antibody interactions during sensing, self-verification through providing signals of two modes, and reduced false readout. This study demonstrates the complementary nature of the electrochemical and SPR modes in biosensing, with the electrochemical mode being highly sensitive and the SPR mode providing superior tracking of molecular recognition behaviors. The presented sensor represents a significant innovation in cardiovascular disease management and can be applied to monitor other clinically important biomolecules.
Collapse
Affiliation(s)
- Nawab Singh
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, United States
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad, Hyderabad 502284, India
| | - Ajeet Kaushik
- Department of Environmental Engineering, Florida Polytechnic University, Lakeland, Florida 33805, United States
| | - Inayathullah Ghori
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad, Hyderabad 502284, India
| | - Prabhakar Rai
- Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
| | - Liang Dong
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, United States
- Microelectronics Research Center, Iowa State University, Ames, Iowa 50011, United States
| | - Ashutosh Sharma
- Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
| | - Bansi D Malhotra
- Environment & Biomedical Metrology Section, CSIR-National Physical Laboratory, New Delhi 110012, India
| | - Renu John
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad, Hyderabad 502284, India
| |
Collapse
|
3
|
Zhang J, Xiao M, Su RG, Kong T, Zhang D, Zhou CW, Cheng GS. Silicon nanowire FET biosensor and its application in acute myocardial infarction. NANOTECHNOLOGY 2023; 35:112001. [PMID: 38081075 DOI: 10.1088/1361-6528/ad1438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 12/11/2023] [Indexed: 12/28/2023]
Abstract
Over the last two decades, silicon nanowire field-effect transistors (SiNW-FETs) with prominent merits of high surface-to-volume ratio, excellent biocompatibility and mature fabrication with standard silicon technology, have been widely studied as ultrahigh sensitive biosensors for the detection of target biomolecules, such as proteins, nucleic acids, cells and viruses so on. Herein we present a comprehensive review of the fundamental aspects of SiNW-FET biosensors, involving the working principle and the device fabrication, surface functionalization, and system integration with fluid exchange and electrical detection. Futhermore, we emphatically discuss the electrical detection of cardiac-specific biomarkers related to acute myocardial infarction disease. SiNW-FET biosensors are being increasingly exploited as promising diagnostic devices, which provide high sensitivity, high integration density, high speed sampling, strong specificity, and real-time and label-free detection for simple and cheap clinical testing.
Collapse
Affiliation(s)
- J Zhang
- College of Electronic and Information Engineering, Changshu Institute of Technology, Changshu 215500, People's Republic of China
| | - M Xiao
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - R G Su
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - T Kong
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - D Zhang
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - C W Zhou
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA 90089, United States of America
| | - G S Cheng
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| |
Collapse
|
4
|
Chen S, Bashir R. Advances in field-effect biosensors towards point-of-use. NANOTECHNOLOGY 2023; 34:492002. [PMID: 37625391 PMCID: PMC10523595 DOI: 10.1088/1361-6528/acf3f0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 08/11/2023] [Accepted: 08/25/2023] [Indexed: 08/27/2023]
Abstract
The future of medical diagnostics calls for portable biosensors at the point of care, aiming to improve healthcare by reducing costs, improving access, and increasing quality-what is called the 'triple aim'. Developing point-of-care sensors that provide high sensitivity, detect multiple analytes, and provide real time measurements can expand access to medical diagnostics for all. Field-effect transistor (FET)-based biosensors have several advantages, including ultrahigh sensitivity, label-free and amplification-free detection, reduced cost and complexity, portability, and large-scale multiplexing. They can also be integrated into wearable or implantable devices and provide continuous, real-time monitoring of analytesin vivo, enabling early detection of biomarkers for disease diagnosis and management. This review analyzes advances in the sensitivity, parallelization, and reusability of FET biosensors, benchmarks the limit of detection of the state of the art, and discusses the challenges and opportunities of FET biosensors for future healthcare applications.
Collapse
Affiliation(s)
- Sihan Chen
- Holonyak Micro and Nanotechnology Laboratory, The Grainger College of Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States of America
| | - Rashid Bashir
- Holonyak Micro and Nanotechnology Laboratory, The Grainger College of Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States of America
- Department of Bioengineering, The Grainger College of Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States of America
- Department of Biomedical and Translational Sciences, Carle Illinois College of Medicine, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States of America
| |
Collapse
|
5
|
Li H, Li D, Chen H, Yue X, Fan K, Dong L, Wang G. Application of Silicon Nanowire Field Effect Transistor (SiNW-FET) Biosensor with High Sensitivity. SENSORS (BASEL, SWITZERLAND) 2023; 23:6808. [PMID: 37571591 PMCID: PMC10422280 DOI: 10.3390/s23156808] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/12/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023]
Abstract
As a new type of one-dimensional semiconductor nanometer material, silicon nanowires (SiNWs) possess good application prospects in the field of biomedical sensing. SiNWs have excellent electronic properties for improving the detection sensitivity of biosensors. The combination of SiNWs and field effect transistors (FETs) formed one special biosensor with high sensitivity and target selectivity in real-time and label-free. Recently, SiNW-FETs have received more attention in fields of biomedical detection. Here, we give a critical review of the progress of SiNW-FETs, in particular, about the reversible surface modification methods. Moreover, we summarized the applications of SiNW-FETs in DNA, protein, and microbial detection. We also discuss the related working principle and technical approaches. Our review provides an extensive discussion for studying the challenges in the future development of SiNW-FETs.
Collapse
Affiliation(s)
- Huiping Li
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronic Information, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Dujuan Li
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronic Information, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Huiyi Chen
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronic Information, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Xiaojie Yue
- The Children’s Hospital of Zhejiang University School of Medicine, Hangzhou 310052, China
| | - Kai Fan
- School of Automation, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Linxi Dong
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronic Information, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Gaofeng Wang
- Ministry of Education Engineering Research Center of Smart Microsensors and Microsystems, School of Electronic Information, Hangzhou Dianzi University, Hangzhou 310018, China
| |
Collapse
|
6
|
Liang T, Chen J, Yan R, Jiang H, Li H. Research on Detection of Ultra-Low Concentration Anthrax Protective Antigen Using Graphene Field-Effect Transistor Biosensor. SENSORS (BASEL, SWITZERLAND) 2023; 23:5820. [PMID: 37447669 DOI: 10.3390/s23135820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 05/28/2023] [Accepted: 06/01/2023] [Indexed: 07/15/2023]
Abstract
BACKGROUND Protective antigen (PA) is an important biomarker for the early diagnosis of anthrax, and the accurate detection of protective antigen under extremely low concentration conditions has always been a hot topic in the biomedical field. To complete the diagnosis of anthrax in a timely manner, it is necessary to detect PA at extremely low concentrations, as the amount of PA produced in the early stage of anthrax invasion is relatively small. Graphene field-effect transistor (Gr-FET) biosensors are a new type of material for preparing biosensors, with the advantages of a short detection time and ultra-low detection limit. METHODS The effect of different concentrations of diluents on the affinity of PA monoclonal antibodies was determined via an ELISA experiment. Combined with the Debye equation, 0.01 × PBS solution was finally selected as the diluent for the experiment. Then, a PA monoclonal antibody was selected as the bio-recognition element to construct a Gr-FET device based on CVD-grown graphene, which was used to detect the concentration of PA while recording the response time, linear range, detection limit, and other parameters. RESULTS The experimental results showed that the biosensor could quickly detect PA, with a linear range of 10 fg/mL to 100 pg/mL and a detection limit of 10 fg/mL. In addition, the biosensor showed excellent specificity and repeatability. CONCLUSIONS By constructing a Gr-FET device based on CVD-grown graphene and selecting a PA monoclonal antibody as the bio-recognition element, a highly sensitive, specific, and repeatable Gr-FET biosensor was successfully prepared for detecting extremely low concentrations of anthrax protective antigen (PA). This biosensor is expected to have a wide range of applications in clinical medicine and biological safety monitoring.
Collapse
Affiliation(s)
- Ting Liang
- The Institute of NBC Defense PLA Army, Beijing 102205, China
| | | | - Rui Yan
- The Institute of NBC Defense PLA Army, Beijing 102205, China
| | - Huaning Jiang
- The Institute of NBC Defense PLA Army, Beijing 102205, China
- Unit No. 32281 of PLA, Chengdu 610200, China
| | - Hexi Li
- The Institute of NBC Defense PLA Army, Beijing 102205, China
- Unit No. 31666 of PLA, Zhangye 610200, China
| |
Collapse
|
7
|
Zhang H, Qiu Y, Osawa F, Itabashi M, Ohshima N, Kajisa T, Sakata T, Izumi T, Sone H. Estimation of the Depletion Layer Thickness in Silicon Nanowire-Based Biosensors from Attomolar-Level Biomolecular Detection. ACS APPLIED MATERIALS & INTERFACES 2023; 15:19892-19903. [PMID: 37046176 DOI: 10.1021/acsami.3c00202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Silicon nanowire (SiNW) biosensors have attracted a lot of attention due to their superior sensitivity. Recently, the dependence of biomolecule detection sensitivity on the nanowire (NW) width, number, and doping density has been partially investigated. However, the primary reason for achieving ultrahigh sensitivity has not been elucidated thus far. In this study, we designed and fabricated SiNW biosensors with different widths (10.8-155 nm) by integrating a complementary metal-oxide-semiconductor process and electron beam lithography. We aimed to investigate the detection limit of SiNW biosensors and reveal the critical effect of the 10-nm-scaled SiNW width on the detection sensitivity. The sensing performance was evaluated by detecting antiovalbumin immunoglobulin G (IgG) with various concentrations (from 6 aM to 600 nM). The initial thickness of the depletion region of the SiNW and the changes in the depletion region due to biomolecule binding were calculated. The basis of this calculation are the resistance change ratios as functions of IgG concentrations using SiNWs with different widths. The calculation results reveal that the proportion of the depletion region over the entire SiNW channel is the essential reason for high-sensitivity detection. Therefore, this study is crucial for an indepth understanding on how to maximize the sensitivity of SiNW biosensors.
Collapse
Affiliation(s)
- Hui Zhang
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma 376-8515, Japan
| | - Yawei Qiu
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma 376-8515, Japan
| | - Fumiya Osawa
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma 376-8515, Japan
| | - Meiko Itabashi
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma 376-8515, Japan
| | - Noriyasu Ohshima
- Graduate School of Medicine, Gunma University, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan
| | - Taira Kajisa
- Graduate School of Interdisciplinary New Science, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585, Japan
| | - Toshiya Sakata
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113-8656, Japan
| | - Takashi Izumi
- Graduate School of Medicine, Gunma University, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan
- Faculty of Health Care, Teikyo Heisei University, 2-51-4, Higashiikebukuro, Toshima-Ku, Tokyo 170-8445, Japan
| | - Hayato Sone
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-Cho, Kiryu, Gunma 376-8515, Japan
| |
Collapse
|
8
|
Sun C, Wang T. Organic thin-film transistors and related devices in life and health monitoring. NANO RESEARCH 2023:1-19. [PMID: 37359073 PMCID: PMC10102697 DOI: 10.1007/s12274-023-5606-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 06/28/2023]
Abstract
The early determination of disease-related biomarkers can significantly improve the survival rate of patients. Thus, a series of explorations for new diagnosis technologies, such as optical and electrochemical methods, have been devoted to life and health monitoring. Organic thin-film transistor (OTFT), as a state-of-the-art nano-sensing technology, has attracted significant attention from construction to application owing to the merits of being label-free, low-cost, facial, and rapid detection with multi-parameter responses. Nevertheless, interference from non-specific adsorption is inevitable in complex biological samples such as body liquid and exhaled gas, so the reliability and accuracy of the biosensor need to be further improved while ensuring sensitivity, selectivity, and stability. Herein, we overviewed the composition, mechanism, and construction strategies of OTFTs for the practical determination of disease-related biomarkers in both body fluids and exhaled gas. The results show that the realization of bio-inspired applications will come true with the rapid development of high-effective OTFTs and related devices. Electronic Supplementary Material Supplementary material is available in the online version of this article at 10.1007/s12274-023-5606-1.
Collapse
Affiliation(s)
- Chenfang Sun
- Tianjin Key Laboratory of Drug Targeting and Bioimaging, Life and Health Intelligent Research Institute, Tianjin University of Technology, Tianjin, 300384 China
| | - Tie Wang
- Tianjin Key Laboratory of Drug Targeting and Bioimaging, Life and Health Intelligent Research Institute, Tianjin University of Technology, Tianjin, 300384 China
| |
Collapse
|
9
|
Li H, Wang S, Li X, Cheng C, Shen X, Wang T. Dual-Channel Detection of Breast Cancer Biomarkers CA15-3 and CEA in Human Serum Using Dialysis-Silicon Nanowire Field Effect Transistor. Int J Nanomedicine 2022; 17:6289-6299. [PMID: 36536938 PMCID: PMC9758920 DOI: 10.2147/ijn.s391234] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/03/2022] [Indexed: 08/08/2023] Open
Abstract
BACKGROUND Breast cancer (BC) is the most common malignant tumors and the leading cause of cancer deaths among women. The early diagnosis and treatment of BC are effective measures that can increase survival rates and reduce mortality. Carbohydrate antigens 15-3 (CA15-3) and carcinoma embryonic antigens (CEA) have been regarded as the most two valuable tumor markers of BC. The combined detection of CA15-3 and CEA could improve the sensitivity and accuracy of early diagnosis for BC. METHODS The multi-channel double-gate silicon nanowire field effect transistor (SiNW-FET) biosensors were fabricated by using the top-down semiconductor manufacturing technology. By surface modification of the different SiNW surfaces with monoclonal CA15-3 and CEA antibodies separately, the prepared SiNW-FET was processed into biosensor for dual-channel detection of CA15-3 and CEA. RESULTS The prepared SiNW-FET biosensors were proved to have high sensitivity and specificity for the dual-channel detection of CA15-3 and CEA, and the detection limit is as low as 0.1U/mL CA15-3 and 0.01 ng/mL CEA. Moreover, the SiNW-FET biosensors were able to detect CA15-3 and CEA in serum by connecting a miniature hemodialyzer. CONCLUSION The present study reported a SiNW-FET biosensor for dual-channel detection of breast cancer biomarkers CA15-3 and CEA in serum, which has potential clinical application value for the early diagnosis and curative effect observation of BC.
Collapse
Affiliation(s)
- Hang Li
- Department of General Surgery, Suzhou Ninth Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, People’s Republic of China
| | - Shuai Wang
- Department of General Surgery, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu Province, People’s Republic of China
| | - Xiaosong Li
- Department of General Surgery, Suzhou Ninth Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, People’s Republic of China
| | - Cong Cheng
- Department of General Surgery, Nanjing Medical University Affiliated Wuxi People’s Hospital, Wuxi, Jiangsu Province, People’s Republic of China
| | - Xiping Shen
- Department of General Surgery, Suzhou Ninth Hospital Affiliated to Soochow University, Suzhou, Jiangsu Province, People’s Republic of China
| | - Tong Wang
- Department of General Surgery, Nanjing Medical University Affiliated Wuxi People’s Hospital, Wuxi, Jiangsu Province, People’s Republic of China
| |
Collapse
|
10
|
Lin H, Kasai N, Xu N, Nakajima H, Kato S, Zeng H, Lin JM, Mao S, Uchiyama K. Localized hydrodynamic flow confinement assisted nanowire sensor for ultrasensitive protein detection. Biosens Bioelectron 2022; 218:114788. [DOI: 10.1016/j.bios.2022.114788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 09/27/2022] [Accepted: 10/03/2022] [Indexed: 11/02/2022]
|
11
|
Amen MT, Pham TTT, Cheah E, Tran DP, Thierry B. Metal-Oxide FET Biosensor for Point-of-Care Testing: Overview and Perspective. Molecules 2022; 27:molecules27227952. [PMID: 36432052 PMCID: PMC9698540 DOI: 10.3390/molecules27227952] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/12/2022] [Accepted: 11/14/2022] [Indexed: 11/18/2022] Open
Abstract
Metal-oxide semiconducting materials are promising for building high-performance field-effect transistor (FET) based biochemical sensors. The existence of well-established top-down scalable manufacturing processes enables the reliable production of cost-effective yet high-performance sensors, two key considerations toward the translation of such devices in real-life applications. Metal-oxide semiconductor FET biochemical sensors are especially well-suited to the development of Point-of-Care testing (PoCT) devices, as illustrated by the rapidly growing body of reports in the field. Yet, metal-oxide semiconductor FET sensors remain confined to date, mainly in academia. Toward accelerating the real-life translation of this exciting technology, we review the current literature and discuss the critical features underpinning the successful development of metal-oxide semiconductor FET-based PoCT devices that meet the stringent performance, manufacturing, and regulatory requirements of PoCT.
Collapse
|
12
|
Nahak BK, Mishra A, Preetam S, Tiwari A. Advances in Organ-on-a-Chip Materials and Devices. ACS APPLIED BIO MATERIALS 2022; 5:3576-3607. [PMID: 35839513 DOI: 10.1021/acsabm.2c00041] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The organ-on-a-chip (OoC) paves a way for biomedical applications ranging from preclinical to clinical translational precision. The current trends in the in vitro modeling is to reduce the complexity of human organ anatomy to the fundamental cellular microanatomy as an alternative of recreating the entire cell milieu that allows systematic analysis of medicinal absorption of compounds, metabolism, and mechanistic investigation. The OoC devices accurately represent human physiology in vitro; however, it is vital to choose the correct chip materials. The potential chip materials include inorganic, elastomeric, thermoplastic, natural, and hybrid materials. Despite the fact that polydimethylsiloxane is the most commonly utilized polymer for OoC and microphysiological systems, substitute materials have been continuously developed for its advanced applications. The evaluation of human physiological status can help to demonstrate using noninvasive OoC materials in real-time procedures. Therefore, this Review examines the materials used for fabricating OoC devices, the application-oriented pros and cons, possessions for device fabrication and biocompatibility, as well as their potential for downstream biochemical surface alteration and commercialization. The convergence of emerging approaches, such as advanced materials, artificial intelligence, machine learning, three-dimensional (3D) bioprinting, and genomics, have the potential to perform OoC technology at next generation. Thus, OoC technologies provide easy and precise methodologies in cost-effective clinical monitoring and treatment using standardized protocols, at even personalized levels. Because of the inherent utilization of the integrated materials, employing the OoC with biomedical approaches will be a promising methodology in the healthcare industry.
Collapse
Affiliation(s)
- Bishal Kumar Nahak
- Institute of Advanced Materials, IAAM, Gammalkilsvägen 18, Ulrika 59053, Sweden
| | - Anshuman Mishra
- Institute of Advanced Materials, IAAM, Gammalkilsvägen 18, Ulrika 59053, Sweden
| | - Subham Preetam
- Institute of Advanced Materials, IAAM, Gammalkilsvägen 18, Ulrika 59053, Sweden
| | - Ashutosh Tiwari
- Institute of Advanced Materials, IAAM, Gammalkilsvägen 18, Ulrika 59053, Sweden
| |
Collapse
|
13
|
Hu P, Qin H, Hu K, Dai R, Wang Z, Huang K. Constructing a defect-rich hydroxide nanoenzyme sensor based on dielectric barrier discharge microplasma etching for sensitive detection of thiamine hydrochloride and hydrogen peroxide. J Colloid Interface Sci 2022; 628:597-606. [DOI: 10.1016/j.jcis.2022.07.151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 07/23/2022] [Accepted: 07/25/2022] [Indexed: 11/17/2022]
|
14
|
Khodadadian A, Parvizi M, Teshnehlab M, Heitzinger C. Rational Design of Field-Effect Sensors Using Partial Differential Equations, Bayesian Inversion, and Artificial Neural Networks. SENSORS (BASEL, SWITZERLAND) 2022; 22:4785. [PMID: 35808281 PMCID: PMC9269136 DOI: 10.3390/s22134785] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 02/06/2023]
Abstract
Silicon nanowire field-effect transistors are promising devices used to detect minute amounts of different biological species. We introduce the theoretical and computational aspects of forward and backward modeling of biosensitive sensors. Firstly, we introduce a forward system of partial differential equations to model the electrical behavior, and secondly, a backward Bayesian Markov-chain Monte-Carlo method is used to identify the unknown parameters such as the concentration of target molecules. Furthermore, we introduce a machine learning algorithm according to multilayer feed-forward neural networks. The trained model makes it possible to predict the sensor behavior based on the given parameters.
Collapse
Affiliation(s)
- Amirreza Khodadadian
- Institute of Applied Mathematics, Leibniz University Hannover, Welfengarten 1, 30167 Hannover, Germany;
| | - Maryam Parvizi
- Institute of Applied Mathematics, Leibniz University Hannover, Welfengarten 1, 30167 Hannover, Germany;
- Cluster of Excellence PhoenixD (Photonics, Optics, and Engineering-Innovation Across Disciplines), Leibniz University Hannover, 30167 Hannover, Germany
| | - Mohammad Teshnehlab
- Faculty of Electrical Engineering, K. N. Toosi University of Technology, Tehran 19697, Iran;
| | - Clemens Heitzinger
- Institute of Analysis and Scientific Computing, TU Wien, Wiedner Hauptstrasse 8–10, 1040 Vienna, Austria;
- Center for Artificial Intelligence and Machine Learning (CAIML), TU Wien, 1040 Vienna, Austria
| |
Collapse
|
15
|
A Fast and Label-Free Potentiometric Method for Direct Detection of Glutamine with Silicon Nanowire Biosensors. BIOSENSORS 2022; 12:bios12060368. [PMID: 35735517 PMCID: PMC9221423 DOI: 10.3390/bios12060368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 05/24/2022] [Accepted: 05/24/2022] [Indexed: 11/17/2022]
Abstract
In this paper, a potentiometric method is used for monitoring the concentration of glutamine in the bioprocess by employing silicon nanowire biosensors. Just one hydrolyzation reaction was used, which is much more convenient compared with the two-stage reactions in the published papers. For the silicon nanowire biosensor, the Al2O3 sensing layer provides a highly sensitive to solution-pH, which has near-Nernstian sensitivity. The sensitive region to detect glutamine is from ≤40 μM to 20 mM. The Sigmoidal function was used to model the pH-signal variation versus the glutamine concentration. Compared with the amperometric methods, a consistent result from different devices could be directly obtained. It is a fast and direct method achieved with our real-time setup. Also, it is a label-free method because just the pH variation of the solution is monitored. The obtained results show the feasibility of the potentiometric method for monitoring the glutamine concentrations in fermentation processes. Our approach in this paper can be applied to various analytes.
Collapse
|
16
|
Rasmi Y, Mosa OF, Alipour S, Heidari N, Javanmard F, Golchin A, Gholizadeh-Ghaleh Aziz S. Significance of Cardiac Troponins as an Identification Tool in COVID-19 Patients Using Biosensors: An Update. Front Mol Biosci 2022; 9:821155. [PMID: 35281265 PMCID: PMC8912935 DOI: 10.3389/fmolb.2022.821155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 01/17/2022] [Indexed: 01/08/2023] Open
Abstract
Coronavirus disease 2019 (COVID-19) has rapidly developed as a global health emergency. Respiratory diseases are significant causes of morbidity and mortality in these patients with a spectrum of different diseases, from asymptomatic subclinical infection to the progression of severe pneumonia and subsequent acute respiratory distress syndrome. Individuals with cardiovascular disease are more likely to become infected with SARS-CoV-2 and develop severe symptoms. Hence, patients with underlying cardiovascular disease mortality rate are over three times. Furthermore, note that patients with a history of cardiovascular disease are more likely to have higher cardiac biomarkers, especially cardiac troponins, than infected patients, especially those with severe disease, making these patients more susceptible to cardiac damage caused by SARS-2-CoV. Biomarkers are important in decision-making to facilitate the efficient allocation of resources. Viral replication in the heart muscle can lead to a cascade of inflammatory processes that lead to fibrosis and, ultimately, cardiac necrosis. Elevated troponin may indicate damage to the heart muscle and may predict death. After the first Chinese analysis, increased cardiac troponin value was observed in a significant proportion of patients, suggesting that myocardial damage is a possible pathogenic mechanism leading to severe disease and death. However, the prognostic performance of troponin and whether its value is affected by different comorbidities present in COVID-19 patients are not known. This review aimed to assess the diagnostic value of troponin to offer insight into pathophysiological mechanisms and reported new assessment methods, including new biosensors for troponin in patients with COVID-19.
Collapse
Affiliation(s)
- Yousef Rasmi
- Cellular and Molecular Research Center, Urmia University of Medical Sciences, Urmia, Iran
- Department of Biochemistry, School of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| | - Osama F Mosa
- Public Health Department, Health Sciences College at Lieth, Umm Al Qura University, Mecca, Saudi Arabia
- Biochemistry Department, Bukhara State Medical Institute Named After Abu Ali ibn Sino, Bukhara, Uzbekistan
| | - Shahriar Alipour
- Department of Biochemistry, School of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| | - Nadia Heidari
- Department of Clinical Biochemistry, Metabolic Disorders Research Center, Golestan University of Medical Sciences, Gorgan, Iran
| | - Farzaneh Javanmard
- Department of Pathology, Urmia University of Medical Science, Urmia, Iran
| | - Ali Golchin
- Department of Biochemistry, School of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| | - Shiva Gholizadeh-Ghaleh Aziz
- Department of Biochemistry, School of Medicine, Urmia University of Medical Sciences, Urmia, Iran
- Nephrology and Kidney Transplant Research Center, Clinical Research Institute, Urmia University of Medical Sciences, Urmia, Iran
| |
Collapse
|
17
|
Cheah E, Tran DP, Amen MT, Arrua RD, Hilder EF, Thierry B. Integrated Platform Addressing the Finger-Prick Blood Processing Challenges of Point-of-Care Electrical Biomarker Testing. Anal Chem 2022; 94:1256-1263. [DOI: 10.1021/acs.analchem.1c04470] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Edward Cheah
- Future Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia
- ARC Centre of Excellence for Convergent Bio-Nano Science and Technology, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| | - Duy P. Tran
- Future Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia
- ARC Centre of Excellence for Convergent Bio-Nano Science and Technology, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| | - Mohamed T. Amen
- Future Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia
- ARC Centre of Excellence for Convergent Bio-Nano Science and Technology, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| | - R. Dario Arrua
- Future Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| | - Emily F. Hilder
- Future Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| | - Benjamin Thierry
- Future Industries Institute, University of South Australia, Mawson Lakes, South Australia 5095, Australia
- ARC Centre of Excellence for Convergent Bio-Nano Science and Technology, University of South Australia, Mawson Lakes, South Australia 5095, Australia
| |
Collapse
|
18
|
Krsihna BV, Ahmadsaidulu S, Teja SST, Jayanthi D, Navaneetha A, Reddy PR, Prakash MD. Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2. SILICON 2022; 14. [PMCID: PMC8435128 DOI: 10.1007/s12633-021-01372-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The most affected disease in recent years is Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2) that is notable as COVID-19. It has been started as a disease in one place and arisen as a pandemic throughout the world. A serious health problem is developed in the lungs due to the effect of this coronavirus. Sometimes it may result in death as a consequence of extensive alveolar damage and progressive respiratory failure. Hence, early detection and appropriate diagnosis of corona virus in patient’s body is very essential to save the lives of affected patients This work evolves a Silicon (Si) based label-free electrical device i.e. the reduced graphene oxide field-effect transistor (rGO FET) for SARS-CoV-2 detection. Firstly rGO FET functionalized with SARS-CoV-2 monoclonal antibodies (mAbs). Then the rGO FET characteristic response is observed to detect the antibody-antigen reaction of SARS-CoV-2 with different molar ranges. The developed GFET shows better performance towards the drain current and limit-of-detection (LoD) up to 2E-18 M. Therefore, we believe that an intense response was observed than the earlier developed devices and signifies impressive capability for subsequent implementation in point-of-care (PoC) diagnostic tests.
Collapse
Affiliation(s)
- B. Vamsi Krsihna
- Department of ECE, Koneru Lakshmaih Education Foundation, Guntur, 522502 Andhra Pradesh India
| | - Shaik Ahmadsaidulu
- Department of ECE, Velagapudi Ramakrishna Siddhartha Engineering College, 520007 Kanuru, Andhra Pradesh India
| | - Surapaneni Sai Tarun Teja
- Department of ECE, Velagapudi Ramakrishna Siddhartha Engineering College, 520007 Kanuru, Andhra Pradesh India
| | - D. Jayanthi
- Department of ECE, Gokaraju Rangaraju Institute of Engineering & Technology, 500090 Hyderabad, Telangana India
| | - Alluri Navaneetha
- Department of ECE, Mahatma Gandhi Institute of Technology, 500075 Hyderabad, Telangana India
| | - P. Rahul Reddy
- Department of ECE, Geethanjali Institute of Science and Technology, 524137 Nellore, Andhra Pradesh India
| | - M. Durga Prakash
- Department of ECE, Velagapudi Ramakrishna Siddhartha Engineering College, 520007 Kanuru, Andhra Pradesh India
| |
Collapse
|
19
|
Yin M, Alexander Kim Z, Xu B. Micro/Nanofluidic‐Enabled Biomedical Devices: Integration of Structural Design and Manufacturing. ADVANCED NANOBIOMED RESEARCH 2021. [DOI: 10.1002/anbr.202100117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Affiliation(s)
- Mengtian Yin
- Department of Mechanical and Aerospace Engineering University of Virginia Charlottesville VA 22904 USA
| | - Zachary Alexander Kim
- Department of Mechanical and Aerospace Engineering University of Virginia Charlottesville VA 22904 USA
| | - Baoxing Xu
- Department of Mechanical and Aerospace Engineering University of Virginia Charlottesville VA 22904 USA
| |
Collapse
|
20
|
Zhang G, Zeng H, Liu J, Nagashima K, Takahashi T, Hosomi T, Tanaka W, Yanagida T. Nanowire-based sensor electronics for chemical and biological applications. Analyst 2021; 146:6684-6725. [PMID: 34667998 DOI: 10.1039/d1an01096d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Detection and recognition of chemical and biological species via sensor electronics are important not only for various sensing applications but also for fundamental scientific understanding. In the past two decades, sensor devices using one-dimensional (1D) nanowires have emerged as promising and powerful platforms for electrical detection of chemical species and biologically relevant molecules due to their superior sensing performance, long-term stability, and ultra-low power consumption. This paper presents a comprehensive overview of the recent progress and achievements in 1D nanowire synthesis, working principles of nanowire-based sensors, and the applications of nanowire-based sensor electronics in chemical and biological analytes detection and recognition. In addition, some critical issues that hinder the practical applications of 1D nanowire-based sensor electronics, including device reproducibility and selectivity, stability, and power consumption, will be highlighted. Finally, challenges, perspectives, and opportunities for developing advanced and innovative nanowire-based sensor electronics in chemical and biological applications are featured.
Collapse
Affiliation(s)
- Guozhu Zhang
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Hao Zeng
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Jiangyang Liu
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Kazuki Nagashima
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Tsunaki Takahashi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Takuro Hosomi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Wataru Tanaka
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Takeshi Yanagida
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka, 816-8580, Japan
| |
Collapse
|
21
|
Lim WY, Lan BL, Ramakrishnan N. Emerging Biosensors to Detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2): A Review. BIOSENSORS 2021; 11:bios11110434. [PMID: 34821650 PMCID: PMC8615996 DOI: 10.3390/bios11110434] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/09/2021] [Accepted: 10/14/2021] [Indexed: 05/07/2023]
Abstract
Coronavirus disease (COVID-19) is a global health crisis caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) is the gold standard test for diagnosing COVID-19. Although it is highly accurate, this lab test requires highly-trained personnel and the turn-around time is long. Rapid and inexpensive immuno-diagnostic tests (antigen or antibody test) are available, but these point of care (POC) tests are not as accurate as the RT-PCR test. Biosensors are promising alternatives to these rapid POC tests. Here we review three types of recently developed biosensors for SARS-CoV-2 detection: surface plasmon resonance (SPR)-based, electrochemical and field-effect transistor (FET)-based biosensors. We explain the sensing principles and discuss the advantages and limitations of these sensors. The accuracies of these sensors need to be improved before they could be translated into POC devices for commercial use. We suggest potential biorecognition elements with highly selective target-analyte binding that could be explored to increase the true negative detection rate. To increase the true positive detection rate, we suggest two-dimensional materials and nanomaterials that could be used to modify the sensor surface to increase the sensitivity of the sensor.
Collapse
|
22
|
Lee D, Jung WH, Lee S, Yu ES, Lee T, Kim JH, Song HS, Lee KH, Lee S, Han SK, Choi MC, Ahn DJ, Ryu YS, Kim C. Ionic contrast across a lipid membrane for Debye length extension: towards an ultimate bioelectronic transducer. Nat Commun 2021; 12:3741. [PMID: 34145296 PMCID: PMC8213817 DOI: 10.1038/s41467-021-24122-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 06/03/2021] [Indexed: 11/09/2022] Open
Abstract
Despite technological advances in biomolecule detections, evaluation of molecular interactions via potentiometric devices under ion-enriched solutions has remained a long-standing problem. To avoid severe performance degradation of bioelectronics by ionic screening effects, we cover probe surfaces of field effect transistors with a single film of the supported lipid bilayer, and realize respectable potentiometric signals from receptor-ligand bindings irrespective of ionic strength of bulky solutions by placing an ion-free water layer underneath the supported lipid bilayer. High-energy X-ray reflectometry together with the circuit analysis and molecular dynamics simulation discovered biochemical findings that effective electrical signals dominantly originated from the sub-nanoscale conformational change of lipids in the course of receptor-ligand bindings. Beyond thorough analysis on the underlying mechanism at the molecular level, the proposed supported lipid bilayer-field effect transistor platform ensures the world-record level of sensitivity in molecular detection with excellent reproducibility regardless of molecular charges and environmental ionic conditions.
Collapse
Affiliation(s)
- Donggeun Lee
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea.,Department of Electrical & Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Woo Hyuk Jung
- Department of Chemical and Biological Engineering, Korea University, Seoul, Republic of Korea
| | - Suho Lee
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Eui-Sang Yu
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Taikjin Lee
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Jae Hun Kim
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Hyun Seok Song
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Kwan Hyi Lee
- Center for Biomaterials, Korea Institute of Science and Technology, Seoul, Republic of Korea.,KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul, Republic of Korea
| | - Seok Lee
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Sang-Kook Han
- Department of Electrical & Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Myung Chul Choi
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Dong June Ahn
- Department of Chemical and Biological Engineering, Korea University, Seoul, Republic of Korea. .,KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul, Republic of Korea.
| | - Yong-Sang Ryu
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea. .,KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul, Republic of Korea.
| | - Chulki Kim
- Sensor System Research Center, Korea Institute of Science and Technology, Seoul, Republic of Korea.
| |
Collapse
|
23
|
Sun C, Li R, Song Y, Jiang X, Zhang C, Cheng S, Hu W. Ultrasensitive and Reliable Organic Field-Effect Transistor-Based Biosensors in Early Liver Cancer Diagnosis. Anal Chem 2021; 93:6188-6194. [DOI: 10.1021/acs.analchem.1c00372] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Chenfang Sun
- Department of Chemistry, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, School of Science, Tianjin University, Tianjin 300072, China
| | - Rui Li
- Department of Chemistry, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, School of Science, Tianjin University, Tianjin 300072, China
| | - Yaru Song
- Department of Chemistry, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, School of Science, Tianjin University, Tianjin 300072, China
| | - Xiaoqian Jiang
- Department of Chemistry, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, School of Science, Tianjin University, Tianjin 300072, China
| | - Congcong Zhang
- Institute for Advanced Interdisciplinary Research (iAIR), Collaborative Innovation Center of Technology and Equipment for Biological Diagnosis and Therapy in Universities of Shandong, University of Jinan, Jinan 250011, China
| | - Shanshan Cheng
- Department of Chemistry, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, School of Science, Tianjin University, Tianjin 300072, China
- Joint School of National University of Singapore and Tianjin University, Fuzhou International Campus, Tianjin University, Binhai New City, Fuzhou 350207, China
| | - Wenping Hu
- Department of Chemistry, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, School of Science, Tianjin University, Tianjin 300072, China
- Beijing National Laboratory for Molecular Science, Key Laboratory of Organic Solids, Institution of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- Joint School of National University of Singapore and Tianjin University, Fuzhou International Campus, Tianjin University, Binhai New City, Fuzhou 350207, China
| |
Collapse
|
24
|
Combination of Aptamer Amplifier and Antigen-Binding Fragment Probe as a Novel Strategy to Improve Detection Limit of Silicon Nanowire Field-Effect Transistor Immunosensors. SENSORS 2021; 21:s21020650. [PMID: 33477777 PMCID: PMC7832338 DOI: 10.3390/s21020650] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/23/2020] [Accepted: 01/06/2021] [Indexed: 11/17/2022]
Abstract
Detecting proteins at low concentrations in high-ionic-strength conditions by silicon nanowire field-effect transistors (SiNWFETs) is severely hindered due to the weakened signal, primarily caused by screening effects. In this study, aptamer as a signal amplifier, which has already been reported by our group, is integrated into SiNWFET immunosensors employing antigen-binding fragments (Fab) as the receptors to improve its detection limit for the first time. The Fab-SiNWFET immunosensors were developed by immobilizing Fab onto Si surfaces modified with either 3-aminopropyltriethoxysilane (APTES) and glutaraldehyde (GA) (Fab/APTES-SiNWFETs), or mixed self-assembled monolayers (mSAMs) of polyethylene glycol (PEG) and GA (Fab/PEG-SiNWFETs), to detect the rabbit IgG at different concentrations in a high-ionic-strength environment (150 mM Bis-Tris Propane) followed by incubation with R18, an aptamer which can specifically target rabbit IgG, for signal enhancement. Empirical results revealed that the signal produced by the sensors with Fab probes was greatly enhanced compared to the ones with whole antibody (Wab) after detecting similar concentrations of rabbit IgG. The Fab/PEG-SiNWFET immunosensors exhibited an especially improved limit of detection to determine the IgG level down to 1 pg/mL, which has not been achieved by the Wab/PEG-SiNWFET immunosensors.
Collapse
|
25
|
Gorshkov VN, Tereshchuk VV, Sareh P. Roughening transition as a driving factor in the formation of self-ordered one-dimensional nanostructures. CrystEngComm 2021. [DOI: 10.1039/d0ce01404d] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Peculiar scenarios in the dynamics of BCC and FCC 1D-nanostructures leading to the formation of ultra-short, and sometimes stable, high-amplitude surface modulations are analysed and the means of achieving the desired periodicity are discussed.
Collapse
Affiliation(s)
- Vyacheslav N. Gorshkov
- National Technical University of Ukraine, Igor Sikorsky Kyiv Polytechnic Institute
- Kiev 03056
- Ukraine
- Center for Advanced Materials Processing
- Departments of Chemistry and Physics
| | - Vladimir V. Tereshchuk
- National Technical University of Ukraine, Igor Sikorsky Kyiv Polytechnic Institute
- Kiev 03056
- Ukraine
| | - Pooya Sareh
- Creative Design Engineering Lab (Cdel)
- Department of Mechanical
- Materials, and Aerospace Engineering
- School of Engineering
- University of Liverpool
| |
Collapse
|
26
|
Zhang H, Kikuchi N, Ohshima N, Kajisa T, Sakata T, Izumi T, Sone H. Design and Fabrication of Silicon Nanowire-Based Biosensors with Integration of Critical Factors: Toward Ultrasensitive Specific Detection of Biomolecules. ACS APPLIED MATERIALS & INTERFACES 2020; 12:51808-51819. [PMID: 33142064 DOI: 10.1021/acsami.0c13984] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
As critical factors affecting the sensing performance of silicon nanowire (SiNW) biosensors, the structure, functional interface, and detection target were analyzed and designed to improve sensing performance. For an improved understanding of the dependence of sensor structure on sensitivity, a simple theoretical analysis was proposed to predict the sensitivity of biosensors with different SiNW types, widths, and doping concentrations. Based on the theoretical analysis, a biosensor integrating optimized critical factors was designed and fabricated. Optimizations focusing on the following aspects are considered: (1) employing n-type SiNW and controlling the impurity doping concentration of SiNW at approximately 2 × 1016-6 × 1016 atoms/cm3 to obtain a suitable charge density, (2) minimizing the SiNW width to 16.0 nm to increase the surface area-to-volume ratio, (3) using a native oxide layer on SiNW as a gate insulator to transport the captured charge molecules closer to the SiNW surface, (4) modifying the SiNW surface by 2-aminoethylphosphonic acid coupling to form a high-density self-assembled monolayer for enhancing the stability bound molecules, and (5) functionalizing the SiNW with ovalbumin molecules for specifically capturing the target immunoglobulin G (IgG) molecules. The sensing performance was evaluated by detecting IgG with concentrations ranging from 6 aM to 600 nM and control experiments. The SiNW biosensor revealed ultrahigh sensitivity and specific detection of target IgG with a measured limit of detection of 6 aM. The integration of the critical SiNW biosensor factors provides a significant possibility of a rapid and ultrasensitive diagnosis of diseases at their early stages.
Collapse
Affiliation(s)
- Hui Zhang
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan
| | - Naoki Kikuchi
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan
| | - Noriyasu Ohshima
- Graduate School of Medicine, Gunma University, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan
| | - Taira Kajisa
- Institute of Post-LED Photonics, Tokushima University, 2-1, Minamijosanjima-cho, Tokushima 770-8506, Japan
| | - Toshiya Sakata
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Takashi Izumi
- Graduate School of Medicine, Gunma University, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan
| | - Hayato Sone
- Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan
| |
Collapse
|
27
|
Reyes-Retana JA, Duque-Ossa LC. Acute Myocardial Infarction Biosensor: A Review From Bottom Up. Curr Probl Cardiol 2020; 46:100739. [PMID: 33250264 DOI: 10.1016/j.cpcardiol.2020.100739] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 10/27/2020] [Indexed: 02/09/2023]
Abstract
Acute myocardial infarction (AMI) is a cardiovascular disease that is produced due to a deficiency of oxygen generating irreversible damage in the heart muscle. In diagnosis, electrocardiogram (ECG) investigation has been the main method but is insufficient, so approaches like the measurement of biomarkers levels in plasma or saliva have become one of the most commonly applied strategies for prognosis of AMI, as some of them are specifically related to a heart attack. Many tests are carrying on to determine biological markers changes, but usually, they present disadvantages related to time consumption and laborious work. To overcome the issues, researchers around the world have been developing different ways to enhance detection through the use of biosensors. These diagnostic devices have a biological sensing element associated to a physicochemical transducer that can be made from different materials and configurations giving place to different kinds of detection: Electrical/Electrochemical, Optical and Mechanical. In this review, the authors presents relevant investigations related to the most important biomarkers and biosensors used for their detection having in mind the nanotechnology participation in the process through the application of nanostructures as a good choice for device configuration.
Collapse
Affiliation(s)
- J A Reyes-Retana
- Tecnologico de Monterrey, School of Engineering and Science, Av. Carlos Lazo 100, Santa Fe, La Loma, Mexico City 01389, Mexico. https://tec.mx
| | - L C Duque-Ossa
- Tecnologico de Monterrey, School of Engineering and Science, Av. Carlos Lazo 100, Santa Fe, La Loma, Mexico City 01389, Mexico. https://tec.mx
| |
Collapse
|
28
|
Hu B, Boakye‐Yiadom KO, Yu W, Yuan Z, Ho W, Xu X, Zhang X. Nanomedicine Approaches for Advanced Diagnosis and Treatment of Atherosclerosis and Related Ischemic Diseases. Adv Healthc Mater 2020; 9:e2000336. [PMID: 32597562 DOI: 10.1002/adhm.202000336] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 04/30/2020] [Indexed: 12/16/2022]
Abstract
Cardiovascular diseases (CVDs) remain one of the major causes of mortality worldwide. In response to this and other worldwide health epidemics, nanomedicine has emerged as a rapidly evolving discipline that involves the development of innovative nanomaterials and nanotechnologies and their applications in therapy and diagnosis. Nanomedicine presents unique advantages over conventional medicines due to the superior properties intrinsic to nanoscopic therapies. Once used mainly for cancer therapies, recently, tremendous progress has been made in nanomedicine that has led to an overall improvement in the treatment and diagnosis of CVDs. This review elucidates the pathophysiology and potential targets of atherosclerosis and associated ischemic diseases. It may be fruitful to pursue future work in the nanomedicine-mediated treatment of CVDs based on these targets. A comprehensive overview is then provided featuring the latest preclinical and clinical outcomes in cardiovascular imaging, biomarker detection, tissue engineering, and nanoscale delivery, with specific emphasis on nanoparticles, nanostructured scaffolds, and nanosensors. Finally, the challenges and opportunities regarding the future development and clinical translation of nanomedicine in related fields are discussed. Overall, this review aims to provide a deep and thorough understanding of the design, application, and future development of nanomedicine for atherosclerosis and related ischemic diseases.
Collapse
Affiliation(s)
- Bin Hu
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - Kofi Oti Boakye‐Yiadom
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - Wei Yu
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - Zi‐Wei Yuan
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - William Ho
- Department of Chemical and Materials EngineeringNew Jersey Institute of Technology Newark NJ 07102 USA
| | - Xiaoyang Xu
- Department of Chemical and Materials EngineeringNew Jersey Institute of Technology Newark NJ 07102 USA
| | - Xue‐Qing Zhang
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| |
Collapse
|
29
|
Yousefi F, Movahedpour A, Shabaninejad Z, Ghasemi Y, Rabbani S, Sobnani-Nasab A, Mohammadi S, Hajimoradi B, Rezaei S, Savardashtaki A, Mazoochi M, Mirzaei H. Electrochemical-Based Biosensors: New Diagnosis Platforms for Cardiovascular Disease. Curr Med Chem 2020; 27:2550-2575. [DOI: 10.2174/0929867326666191024114207] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 09/05/2019] [Accepted: 09/12/2019] [Indexed: 02/05/2023]
Abstract
One of the major reasons for mortality throughout the world is cardiovascular diseases.
Therefore, bio-markers of cardiovascular disease are of high importance to diagnose and manage procedure.
Detecting biomarkers provided a promising procedure in developing bio-sensors. Fast, selective,
portable, accurate, inexpensive, and sensitive biomarker sensing instruments will be necessary for
detecting and predicting diseases. One of the cardiac biomarkers may be ordered as C-reactive proteins,
lipoprotein-linked phospho-lipase, troponin I or T, myoglobin, interleukin-6, interleukin-1, tumor necrosis
factor alpha, LDL and myeloperoxidase. The biomarkers are applied to anticipate cardio-vascular
illnesses. Initial diagnoses of these diseases are possible by several techniques; however, they are laborious
and need costly apparatus. Current researches designed various bio-sensors for resolving the respective
issues. Electrochemical instruments and the proposed bio-sensors are preferred over other
methods due to its inexpensiveness, mobility, reliability, repeatability. The present review comprehensively
dealt with detecting biomarkers of cardiovascular disease through electro-chemical techniques.
Collapse
Affiliation(s)
- Fatemeh Yousefi
- Department of Biological Sciences, Faculty of Genetics, Tarbiat Modares University, Tehran, Iran
| | - Ahmad Movahedpour
- Department of Medical Biotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Zahra Shabaninejad
- Department of Biological Sciences, Faculty of Nanotechnology, Tarbiat Modares University, Tehran, Iran
| | - Younes Ghasemi
- Department of Medical Biotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Shahram Rabbani
- Research Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Ali Sobnani-Nasab
- Social Determinants of Health (SDH) Research Center, Kashan University of Medical Sciences, Kashan, Iran
| | - Soheila Mohammadi
- Pharmaceutical Sciences Research Center, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Behzad Hajimoradi
- Cardiology Department of Shohaday-e-Tajrish Hospital Shahid Beheshti University of Medical Sciences (SBMU), Tehran, Iran
| | - Samaneh Rezaei
- Department of Medical Biotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Amir Savardashtaki
- Department of Medical Biotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Majid Mazoochi
- Department of Cardiology, Cardiac Electrophysiology Center, Kashan University of Medical Sciences, Kashan, Iran
| | - Hamed Mirzaei
- Research Center for Biochemistry and Nutrition in Metabolic Diseases, Institute for Basic Sciences, Kashan University of Medical Sciences, Kashan, Iran
| |
Collapse
|
30
|
Gorshkov VN, Tereshchuk VV, Sareh P. Diversity of anisotropy effects in the breakup of metallic FCC nanowires into ordered nanodroplet chains. CrystEngComm 2020. [DOI: 10.1039/c9ce01893j] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The manifestation of anisotropy of surface energy density in the dynamics of 1D-nanostuctures, when annealed below melting temperature in different conditions, is studied on the basis of an analytical approach and Monte Carlo kinetic model.
Collapse
Affiliation(s)
- Vyacheslav N. Gorshkov
- National Technical University of Ukraine
- Igor Sikorsky Kyiv Polytechnic Institute
- Kiev 03056
- Ukraine
| | - Vladimir V. Tereshchuk
- National Technical University of Ukraine
- Igor Sikorsky Kyiv Polytechnic Institute
- Kiev 03056
- Ukraine
| | - Pooya Sareh
- School of Engineering
- University of Liverpool
- London EC2A 1AG
- UK
| |
Collapse
|
31
|
Gas-Phase Synthesis for Label-Free Biosensors: Zinc-Oxide Nanowires Functionalized with Gold Nanoparticles. Sci Rep 2019; 9:17370. [PMID: 31758054 PMCID: PMC6874558 DOI: 10.1038/s41598-019-53960-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 09/26/2019] [Indexed: 12/21/2022] Open
Abstract
Metal oxide semiconductor nanowires have important applications in label-free biosensing due to their ease of fabrication and ultralow detection limits. Typically, chemical functionalization of the oxide surface is necessary for specific biological analyte detection. We instead demonstrate the use of gas-phase synthesis of gold nanoparticles (Au NPs) to decorate zinc oxide nanowire (ZnO NW) devices for biosensing applications. Uniform ZnO NW devices were fabricated using a vapor-solid-liquid method in a chemical vapor deposition (CVD) furnace. Magnetron-sputtering of a Au target combined with a quadrupole mass filter for cluster size selection was used to deposit Au NPs on the ZnO NWs. Without additional functionalization, we electrically detect DNA binding on the nanowire at sub-nanomolar concentrations and visualize individual DNA strands using atomic force microscopy (AFM). By attaching a DNA aptamer for streptavidin to the biosensor, we detect both streptavidin and the complementary DNA strand at sub-nanomolar concentrations. Au NP decoration also enables sub-nanomolar DNA detection in passivated ZnO NWs that are resilient to dissolution in aqueous solutions. This novel method of biosensor functionalization can be applied to many semiconductor materials for highly sensitive and label-free detection of a wide range of biomolecules.
Collapse
|
32
|
Vu CA, Hu WP, Yang YS, Chan HWH, Chen WY. Signal Enhancement of Silicon Nanowire Field-Effect Transistor Immunosensors by RNA Aptamer. ACS OMEGA 2019; 4:14765-14771. [PMID: 31552315 PMCID: PMC6756515 DOI: 10.1021/acsomega.9b01264] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Accepted: 07/11/2019] [Indexed: 05/26/2023]
Abstract
Silicon nanowire field-effect transistors (SiNW-FETs) have been demonstrated as a highly sensitive platform for label-free detection of a variety of biological and chemical entities. However, detecting signal from immunoassays by nano-FETs is severely hindered by the distribution of different charged groups of targeted entities, their binding orientation, and distances to the surface of the FET. Aptamers have been widely applied as a recognition element for plentiful biosensors because of small molecular sizes and moderate to high specific binding affinity with different types of molecules. In this study, we propose an effective approach to enhance the electrical responses of both direct (6×-histidine) and sandwich (amyloid β 1-42) immunoassays in SiNW-FETs with R18, a highly negative charged RNA aptamer against rabbit immunoglobulin G (IgG). Empirical results presented that the immunosensors targeted with R18 expressed a significantly stabilized and amplified signal compared to the ones without this aptamer. The research outcome provides applicability of the highly negative charged aptamer as a bioamplifier for immunoassays by FETs.
Collapse
Affiliation(s)
- Cao-An Vu
- Department
of Chemical and Materials Engineering, National
Central University, Jhongli 320, Taiwan
| | - Wen-Pin Hu
- Department
of Biomedical Informatics, Asia University, Taichung 413, Taiwan
| | - Yuh-Shyong Yang
- Institute
of Biological Science and Technology, National
Chiao Tung University, Hsinchu 300, Taiwan
| | | | - Wen-Yih Chen
- Department
of Chemical and Materials Engineering, National
Central University, Jhongli 320, Taiwan
| |
Collapse
|
33
|
Omstead DT, Sjoerdsma J, Bilgicer B. Polyvalent Nanoobjects for Precision Diagnostics. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:69-88. [PMID: 30811215 DOI: 10.1146/annurev-anchem-061318-114938] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
As our ability to synthesize and modify nanoobjects has improved, efforts to explore nanotechnology for diagnostic purposes have gained momentum. The variety of nanoobjects, especially those with polyvalent properties, displays a wide range of practical and unique properties well suited for applications in various diagnostics. This review briefly covers the broad scope of multivalent nanoobjects and their use in diagnostics, ranging from ex vivo assays and biosensors to in vivo imaging. The nanoobjects discussed here include silica nanoparticles, gold nanoparticles, quantum dots, carbon dots, fullerenes, polymers, dendrimers, liposomes, nanowires, and nanotubes. In this review, we describe recent reports of novel applications of these various nanoobjects, particularly as polyvalent entities designed for diagnostics.
Collapse
Affiliation(s)
- David T Omstead
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA;
| | - Jenna Sjoerdsma
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA;
| | - Basar Bilgicer
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, USA;
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, USA
- Advanced Diagnostics and Therapeutics Initiative, University of Notre Dame, Notre Dame, Indiana 46556, USA
- Mike and Josie Harper Cancer Research Institute, University of Notre Dame, South Bend, Indiana 46617, USA
| |
Collapse
|
34
|
Negahdary M, Behjati-Ardakani M, Heli H. An electrochemical troponin T aptasensor based on the use of a macroporous gold nanostructure. Mikrochim Acta 2019; 186:377. [PMID: 31134399 DOI: 10.1007/s00604-019-3472-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Accepted: 04/29/2019] [Indexed: 11/24/2022]
Abstract
A specific troponin T (TnT) binding aptamer was identified and immobilized on an electrodeposited macroporous gold nanostructure using poly(ethylene glycol) 600, to fabricate a novel and ultrasensitive TnT aptasensor. The transducer surface on the gold disk electrode was characterized by field emission scanning electron microscopy, and immobilization of the aptamer was monitored by open circuit potential measurements. Binding of TnT by the aptamer was monitored by differential pulse voltammetry using ferro/ferricyanide as the redox probe. The aptamer has a high affinity and specificity, and the electrode is sensitive and selective. Best operated at a working potential of 0.23 V (vs. Ag/AgCl), the electrode can detected TnT in the 0.05 to 5.0 ng mL-1 concentration range with a 23 pg mL-1 detection limit. The method was applied to the determination of TnT in 99 spiked human serum samples, and the diagnostic sensitivity and specificity were 94 and 95%, respectively. Graphical abstract Schematic presentation of an electrochemical troponin T aptasensor. A macroporous gold nanostructure was electrodeposited followed by immobilization of a specific TnT aptamer. Binding of TnT by the aptamer was electrochemically monitored. MCH: mercaptohexanol; TnT: troponin T.
Collapse
Affiliation(s)
- Masoud Negahdary
- Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, 8916978477, Iran.,Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, 71936355899, Iran
| | - Mostafa Behjati-Ardakani
- Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, 8916978477, Iran
| | - Hossein Heli
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, 71936355899, Iran.
| |
Collapse
|
35
|
Flexible electrical aptasensor using dielectrophoretic assembly of graphene oxide and its subsequent reduction for cardiac biomarker detection. Sci Rep 2019; 9:5970. [PMID: 30979922 PMCID: PMC6461687 DOI: 10.1038/s41598-019-42506-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 04/01/2019] [Indexed: 01/03/2023] Open
Abstract
Cardiac troponin T (cTnT) is considered a clinical standard for its high specificity and sensitivity when diagnosing acute myocardial infarction; however, most studies on the electrical sensors of cardiac troponin biomarkers have focused on cTnI rather than cTnT. This study presents label-free, low-cost, transparent, and flexible aptamer-based immunosensors for the electrical detection of cTnT using reduced graphene oxide (rGO) sheets. GO was first deposited by AC dielectrophoresis between two predefined source and drain electrodes on a 3-aminopropyltriethoxylsilane-modified polyethylene terephthalate substrate. The GO was then reduced using hydrazine vapour without damaging the substrate, resulting in uniform, controlled, and stable deposition of rGO sheets, and demonstrating more stability than those directly deposited by dielectrophoresis. Amine-modified single-strand DNA aptamers against cTnT were immobilized onto the rGO channels. The relative resistance change of this sensor owing to the attachment of cTnT was quantified as the cTnT concentration decreased from 10 ng/mL to 1 pg/mL in phosphate buffered saline (PBS) and 10-fold diluted human serum in PBS, with the limits of detection being 1.2 pg/mL and 1.7 pg/mL, respectively, which is sufficiently sensitive for clinical applications. High-yield and rapid fabrication of the present rGO sensors will have significant influences on scaled-up fabrication of graphene-based sensors.
Collapse
|
36
|
Szunerits S, Mishyn V, Grabowska I, Boukherroub R. Electrochemical cardiovascular platforms: Current state of the art and beyond. Biosens Bioelectron 2019; 131:287-298. [PMID: 30851492 DOI: 10.1016/j.bios.2019.02.010] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 01/18/2019] [Accepted: 02/04/2019] [Indexed: 01/12/2023]
Abstract
Cardiovascular diseases (CVD) remain the leading cause of death within industrialized nations as well as an increasing cause of mortality and morbidity in many developing countries. Smoking, alcohol consumption and increased level of blood cholesterol are the main CVD risk factors. Other factors, such as the prevalence of overweight/obesity and diabetes, have increased considerably in recent decades and are indirect causes of CVD. Among CVDs, the acute coronary syndrome (ACS) represents the most common cause of emergency hospital admission. Since the prognosis of ACS is directly associated with timely initiation of revascularization, missed, misdiagnosis or late diagnosis have unfavorable medical implications. Early ACS diagnosis can reduce complications and risk of recurrence, finally decreasing the economic burden posed on the health care system as a whole. To decrease the risk of ACS and related CVDs and to reduce associated costs to healthcare systems, a fast management of patients with chest pain has become crucial and urgent. Despite great efforts, biochemical diagnostic approaches of CVDs remain difficult and controversial medical challenges as cardiac biomarkers should be rapidly released into the blood at the time of ischemia and persistent for a sufficient length of time to allow diagnostics, with tests that should be rapid, easy to perform and relatively inexpensive. Early biomarker assessments have involved testing for the total enzyme activity of aspartate aminotransferase (AST), lactate dehydrogenase (LDH) and creatine kinase (CK), which cardiac troponins being the main accepted biomarkers for diagnosing myocardial injury and acute myocardial infarction (AMI). To allow rapid diagnosis, it is necessary to replace the traditional biochemical assays by cardiac biosensor platforms. Among the numerous of possibilities existing today, electrochemical biosensors are important players as they have many of the required characteristics for point-of-care tests. Electrochemical based cardiac biosensors are highly adapted for monitoring the onset and progress of cardiovascular diseases in a fast and accurate manner, while being cheap and scalable devices. This review outlines the state of the art in the development of cardiac electrochemical sensors for the detection of different cardiac biomarkers ranging from troponin to BNP, N-terminal proBNP, and others.
Collapse
Affiliation(s)
- Sabine Szunerits
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN, F-59000 Lille, France.
| | - Vladyslav Mishyn
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN, F-59000 Lille, France
| | - Iwona Grabowska
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland
| | - Rabah Boukherroub
- Univ. Lille, CNRS, Centrale Lille, ISEN, Univ. Valenciennes, UMR 8520-IEMN, F-59000 Lille, France.
| |
Collapse
|
37
|
Chen X, Zhang H, Tunuguntla RH, Noy A. Silicon Nanoribbon pH Sensors Protected by a Barrier Membrane with Carbon Nanotube Porins. NANO LETTERS 2019; 19:629-634. [PMID: 30285454 DOI: 10.1021/acs.nanolett.8b02898] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Limited biocompatibility and fouling propensity can restrict real-world applications of a large variety of biosensors. Biological systems are adept at protecting and separating vital components of biological machinery with semipermeable membranes that often contain defined pores and gates to restrict transmembrane transport only to specific species. Here we use a similar approach for creating fouling-resistant pH sensors. We integrate silicon nanoribbon transistor sensors with an antifouling lipid bilayer coating that contains proton-permeable carbon nanotube porin (CNTP) channels and demonstrate robust pH detection in a variety of complex biological fluids.
Collapse
Affiliation(s)
- Xi Chen
- Physical and Life Sciences Directorate , Lawrence Livermore National Laboratory , Livermore , California 94550 , United States
- School of Natural Sciences , University of California Merced , Merced , California 95343 , United States
| | - Huanan Zhang
- Physical and Life Sciences Directorate , Lawrence Livermore National Laboratory , Livermore , California 94550 , United States
| | - Ramya H Tunuguntla
- Physical and Life Sciences Directorate , Lawrence Livermore National Laboratory , Livermore , California 94550 , United States
| | - Aleksandr Noy
- Physical and Life Sciences Directorate , Lawrence Livermore National Laboratory , Livermore , California 94550 , United States
- School of Natural Sciences , University of California Merced , Merced , California 95343 , United States
| |
Collapse
|
38
|
Ambhorkar P, Wang Z, Ko H, Lee S, Koo KI, Kim K, Cho DID. Nanowire-Based Biosensors: From Growth to Applications. MICROMACHINES 2018; 9:mi9120679. [PMID: 30572645 PMCID: PMC6316191 DOI: 10.3390/mi9120679] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 12/15/2018] [Accepted: 12/17/2018] [Indexed: 01/02/2023]
Abstract
Over the past decade, synthesized nanomaterials, such as carbon nanotube, nanoparticle, quantum dot, and nanowire, have already made breakthroughs in various fields, including biomedical sensors. Enormous surface area-to-volume ratio of the nanomaterials increases sensitivity dramatically compared with macro-sized material. Herein we present a comprehensive review about the working principle and fabrication process of nanowire sensor. Moreover, its applications for the detection of biomarker, virus, and DNA, as well as for drug discovery, are reviewed. Recent advances including self-powering, reusability, sensitivity in high ionic strength solvent, and long-term stability are surveyed and highlighted as well. Nanowire is expected to lead significant improvement of biomedical sensor in the near future.
Collapse
Affiliation(s)
- Pranav Ambhorkar
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.
| | - Zongjie Wang
- Department of Electrical and Computer Engineering, Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3M2, Canada.
| | - Hyuongho Ko
- Department of Electronics, Chungnam National University, Daejeon 34134, Korea.
| | - Sangmin Lee
- Department of Biomedical Engineering, Kyung Hee University, Yongin 17104, Korea.
| | - Kyo-In Koo
- Department of Biomedical Engineering, University of Ulsan, Ulsan 44610, Korea.
| | - Keekyoung Kim
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.
| | - Dong-Il Dan Cho
- ASRI/ISRC, Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea.
| |
Collapse
|
39
|
Jing A, Zhang C, Liang G, Feng W, Tian Z, Jing C. Hyaluronate-Functionalized Graphene for Label-Free Electrochemical Cytosensing. MICROMACHINES 2018; 9:E669. [PMID: 30567299 PMCID: PMC6315524 DOI: 10.3390/mi9120669] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Revised: 12/12/2018] [Accepted: 12/15/2018] [Indexed: 12/15/2022]
Abstract
Electrochemical sensors for early tumor cell detection are currently an important area of research, as this special region directly improves the efficiency of cancer treatment. Functional graphene is a promising alternative for selective recognition and capture of target cancer cells. In our work, an effective cytosensor of hyaluronate-functionalized graphene (HG) was prepared through chemical reduction of graphene oxide. The as-prepared HG nanostructures were characterized with Fourier transform infrared spectroscopy and transmission electron microscopy coupled with cyclic voltammograms and electrochemical impedance spectroscopy, respectively. The self-assembly of HG with ethylene diamine, followed by sodium hyaluronate, enabled the fabrication of a label-free electrochemical impedance spectroscopy cytosensor with high stability and biocompatibility. Finally, the proposed cytosensor exhibited satisfying electrochemical behavior and cell-capture capacity for human colorectal cancer cells HCT-116, and also displayed a wide linear range, from 5.0 × 10² cells∙mL-1 to 5.0 × 10⁶ cells∙mL-1, and a low detection limit of 100 cells∙mL-1 (S/N = 3) for quantification. This work paves the way for graphene applications in electrochemical cytosensing and other bioassays.
Collapse
Affiliation(s)
- Aihua Jing
- School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471023, China.
| | - Chunxin Zhang
- School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471023, China.
| | - Gaofeng Liang
- Medical College, Henan University of Science and Technology, Luoyang 471023, China.
| | - Wenpo Feng
- School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471023, China.
| | - Zhengshan Tian
- School of Chemistry and Chemical Engineering, Pingdingshan University, Pingdingshan 467000, China.
| | - Chenhuan Jing
- Pingdingshan No. 1 Middle School, Pingdingshan 467000, China.
| |
Collapse
|
40
|
Simultaneous detection of three biomarkers related to acute myocardial infarction based on immunosensing biochip. Biosens Bioelectron 2018; 126:767-772. [PMID: 30554098 DOI: 10.1016/j.bios.2018.11.044] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 11/03/2018] [Accepted: 11/27/2018] [Indexed: 12/22/2022]
Abstract
An immunosensing biochip for simultaneous detection of three biomarkers related to acute myocardial infarction (AMI) was developed based on anionic soybean peroxidase (SBP) functionalized nanoprobe and chemiluminescent imaging. The nanoprobes (Ab2-SiO2-SBP) were fabricated by co-immobilization of SBP and one of the detection polyclonal antibodies, anti-cardiac troponin I antigen (anti-cTnI), anti-creatine kinase-MB (anti-CK-MB) and anti-myoglobin (anti-Myo), on the silica nanoparticle surface. The detection sensitivity was enhanced since the large surface area of silica carriers increased the loading of SBP for per sandwiched immunoreaction. The immunosensing biochip designed as 3 × 8 wells array was constructed by simultaneously immobilizing three capture monoclonal antibodies on the same one microtiter well with 2 × 3 active spots. In the presence of target protein, the nanoprobes will be attached onto the spots with high specificity through the sandwiched immunoreactions, which triggered the chemiluminescence (CL) signals on each sensing site of the microtiter plates and allowed to CL imaging of three biomarkers in one well at the same time. Therefore, the proposed biochip was a promising convenient strategy for simultaneous detection of cTnI, CK-MB and Myo, which showed potential application for multianalyte determination in clinical diagnostics.
Collapse
|
41
|
Electrically nanowired-enzymes for probe modification and sensor fabrication. Biosens Bioelectron 2018; 121:223-235. [DOI: 10.1016/j.bios.2018.09.018] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 09/03/2018] [Accepted: 09/04/2018] [Indexed: 11/23/2022]
|
42
|
Kim K, Hall DA, Yao C, Lee JR, Ooi CC, Bechstein DJB, Guo Y, Wang SX. Magnetoresistive biosensors with on-chip pulsed excitation and magnetic correlated double sampling. Sci Rep 2018; 8:16493. [PMID: 30405155 PMCID: PMC6220270 DOI: 10.1038/s41598-018-34720-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Accepted: 10/04/2018] [Indexed: 11/09/2022] Open
Abstract
Giant magnetoresistive (GMR) sensors have been shown to be among the most sensitive biosensors reported. While high-density and scalable sensor arrays are desirable for achieving multiplex detection, scalability remains challenging because of long data acquisition time using conventional readout methods. In this paper, we present a scalable magnetoresistive biosensor array with an on-chip magnetic field generator and a high-speed data acquisition method. The on-chip field generators enable magnetic correlated double sampling (MCDS) and global chopper stabilization to suppress 1/f noise and offset. A measurement with the proposed system takes only 20 ms, approximately 50× faster than conventional frequency domain analysis. A corresponding time domain temperature correction technique is also presented and shown to be able to remove temperature dependence from the measured signal without extra measurements or reference sensors. Measurements demonstrate detection of magnetic nanoparticles (MNPs) at a signal level as low as 6.92 ppm. The small form factor enables the proposed platform to be portable as well as having high sensitivity and rapid readout, desirable features for next generation diagnostic systems, especially in point-of-care (POC) settings.
Collapse
Affiliation(s)
- Kyunglok Kim
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States
| | - Drew A Hall
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, United States
| | - Chengyang Yao
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States
| | - Jung-Rok Lee
- Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul, South Korea
| | - Chin C Ooi
- Department of Chemical Engineering, Stanford University, Stanford, CA, United States
| | - Daniel J B Bechstein
- Department of Mechanical Engineering, Stanford University, Stanford, CA, United States
| | - Yue Guo
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States
| | - Shan X Wang
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States.
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, United States.
| |
Collapse
|
43
|
Aroonyadet N, Jeamsaksiri W, Wisitsoraat A, Tuantranont A. Top-down and sensitive indium oxide nanoribbon field effect transistor biosensor chips integrated with on-chip gate electrodes toward point of care applications. NANOTECHNOLOGY 2018; 29:405505. [PMID: 30020085 DOI: 10.1088/1361-6528/aad435] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We report a scalable, uniform, and sensitive top-down fabricated indium oxide (In2O3) nanoribbon biosensor platform with integrated on-chip gate electrodes using two photolithographic masks. The purpose of this on-chip gate electrode is to control the operational point of the sensor during biomolecular detection replacing the cumbersome external Ag/AgCl electrode. It exhibits excellent capability in gating transistors in an aqueous condition and high stability during the sensing experiment, which is similar to the Ag/AgCl electrode. Its compactness increases the portability and pushes this platform toward a practical use. To demonstrate its capability for detection of biomolecules, we combine this platform with the electronic enzyme-linked immunosorbent assay (ELISA) technique to amplify the signal and to bypass limitation of the Debye screening effect from high salt concentration of physiological samples. Troponin I, a cardiac marker for diagnosis of acute myocardial infarction (AMI), was selected as the target molecule in this study. The In2O3 nanoribbon device offers a high response of 30% toward 0.1 pg ml-1 troponin I concentration and a lower detection limit than that of the commercial ELISA kit on the market by five orders of magnitude. The total assay time from the sample collection to the data acquisition is about 45 min, which is within the constraint of the emergency care application. With the demonstrated sensitivity, uniformity, scalability, quick turn-around time and ability to be integrated, our In2O3 nanoribbon biosensor platform has high potential toward clinical tests for early diagnosis of AMI.
Collapse
Affiliation(s)
- N Aroonyadet
- National Nanotechnology Center, 111 Thailand Science Park, Phahonyothin Road, Khlong Nueng Khlong Luang, Pathum Thani 12120, Thailand
| | | | | | | |
Collapse
|
44
|
Duan L, Yobas L. Label-Free Multiplexed Electrical Detection of Cancer Markers on a Microchip Featuring an Integrated Fluidic Diode Nanopore Array. ACS NANO 2018; 12:7892-7900. [PMID: 30024729 DOI: 10.1021/acsnano.8b02260] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We introduce an integrated array of glass nanopores on a silicon microchip fabricated in a batch process through low-resolution photolithography and standard semiconductor processing tools. By functionalizing each nanopore against a distinct target, we further demonstrate ultrasensitive, label-free, multiplexed electrical detection of cancer-marker proteins in real time through charge-dependent ionic current rectification. As nanofluidic diode biosensors, the nanopores return rapid results, with a limit of detection reaching concentrations as low as attomolars in assay buffer and femtomolars in undiluted untreated human serum, a rare achievement for this class of nanosensors. Multiplexed detection capability has been demonstrated on proteins carcinoembryonic antigen, α-fetoprotein antigen, and human epidermal growth factor receptor-2, with the assay further scalable to a size that is limited by the readout electronics. The nanopores are also found with a considerably advanced detection limit as well as dynamic range in relation to the nanoslit counterparts, validated by the measurements on cardiac protein troponin T. This highly robust assay platform draws from rich nanopore physics and could provide further enhanced detection through concentration polarization, subsequent target enrichment, and serum desalting, all potentially induced by the nanopores presently redundant in the array. This integration would be crucial for removing major obstacles for the practical use of nanopore-based assays.
Collapse
Affiliation(s)
- Lian Duan
- Department of Electronic and Computer Engineering , The Hong Kong University of Science and Technology , Clear Water Bay, Kowloon , Hong Kong SAR, China
| | - Levent Yobas
- Department of Electronic and Computer Engineering , The Hong Kong University of Science and Technology , Clear Water Bay, Kowloon , Hong Kong SAR, China
| |
Collapse
|
45
|
Bakirhan NK, Ozcelikay G, Ozkan SA. Recent progress on the sensitive detection of cardiovascular disease markers by electrochemical-based biosensors. J Pharm Biomed Anal 2018; 159:406-424. [PMID: 30036704 DOI: 10.1016/j.jpba.2018.07.021] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 07/07/2018] [Accepted: 07/16/2018] [Indexed: 12/15/2022]
Abstract
Cardiovascular disease is the most reason for deaths in all over the world. Hence, biomarkers of cardiovascular diseases are very crucial for diagnosis and management process. Biomarker detection demand is opened the important way in biosensor development field. Rapid, cheap, portable, precise, selective and sensitive biomarker sensing devices are needed at this point to detect and predict disease. A cardiac biomarker can be orderable as C-reactive protein, troponin I or T, myoglobin, tumor necrosis factor alpha, interleukin-6, interleukin-1, lipoprotein-associated phospholipase, low-density lipoprotein and myeloperoxidase. They are used for prediction of cardiovascular diseases. There are many methods for early diagnosis of cardiovascular diseases, but these have long time process and expensive devices. In recent studies, different biosensors have been developed to remove the problems in this field. Electrochemical devices and developed biosensors have many superiorities than others such as low cost, mobile, reliable, repeatable, need a little amount of solution. In this review, recent studies were presented as details for cardiovascular disease biomarkers detection using electrochemical methods.
Collapse
Affiliation(s)
- Nurgul K Bakirhan
- Hitit University, Faculty of Arts and Sciences, Department of Chemistry, Corum, Turkey
| | - Goksu Ozcelikay
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Tandogan, Ankara, Turkey
| | - Sibel A Ozkan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Tandogan, Ankara, Turkey.
| |
Collapse
|
46
|
Sposito AJ, Kurdekar A, Zhao J, Hewlett I. Application of nanotechnology in biosensors for enhancing pathogen detection. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2018. [PMID: 29528198 DOI: 10.1002/wnan.1512] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Rapid detection and identification of pathogenic microorganisms is fundamental to minimizing the spread of infectious disease, and informing clinicians on patient treatment strategies. This need has led to the development of enhanced biosensors that utilize state of the art nanomaterials and nanotechnology, and represent the next generation of diagnostics. A primer on nanoscale biorecognition elements such as, nucleic acids, antibodies, and their synthetic analogs (molecular imprinted polymers), will be presented first. Next the application of various nanotechnologies for biosensor transduction will be discussed, along with the inherent nanoscale phenomenon that leads to their improved performance and capabilities in biosensor systems. A future outlook on characterization and quality assurance, nanotoxicity, and nanomaterial integration into lab-on-a-chip systems will provide the closing thoughts. This article is categorized under: Diagnostic Tools > Diagnostic Nanodevices Diagnostic Tools > Biosensing.
Collapse
Affiliation(s)
- Alex J Sposito
- Laboratory of Molecular Virology, Center for Biologics Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland
| | - Aditya Kurdekar
- Laboratories for Nanoscience and Nanotechnology Research, Sri Sathya Sai Institute of Higher Learning, Anantapur, India
| | - Jiangqin Zhao
- Laboratory of Molecular Virology, Center for Biologics Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland
| | - Indira Hewlett
- Laboratory of Molecular Virology, Center for Biologics Evaluation and Research, US Food and Drug Administration, Silver Spring, Maryland
| |
Collapse
|
47
|
Ahmad R, Mahmoudi T, Ahn MS, Hahn YB. Recent advances in nanowires-based field-effect transistors for biological sensor applications. Biosens Bioelectron 2018; 100:312-325. [PMID: 28942344 PMCID: PMC7126762 DOI: 10.1016/j.bios.2017.09.024] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2017] [Revised: 09/08/2017] [Accepted: 09/14/2017] [Indexed: 12/29/2022]
Abstract
Nanowires (NWs)-based field-effect transistors (FETs) have attracted considerable interest to develop innovative biosensors using NWs of different materials (i.e. semiconductors, polymers, etc.). NWs-based FETs provide significant advantages over the other bulk or non-NWs nanomaterials-based FETs. As the building blocks for FET-based biosensors, one-dimensional NWs offer excellent surface-to-volume ratio and are more suitable and sensitive for sensing applications. During the past decade, FET-based biosensors are smartly designed and used due to their great specificity, sensitivity, and high selectivity. Additionally, they have the advantage of low weight, low cost of mass production, small size and compatible with commercial planar processes for large-scale circuitry. In this respect, we summarize the recent advances of NWs-based FET biosensors for different biomolecule detection i.e. glucose, cholesterol, uric acid, urea, hormone, proteins, nucleotide, biomarkers, etc. A comparative sensing performance, present challenges, and future prospects of NWs-based FET biosensors are discussed in detail.
Collapse
Affiliation(s)
- Rafiq Ahmad
- School of Semiconductor and Chemical Engineering, Nanomaterials Processing Research Center, Chonbuk National University, 567 Baekjedaero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Republic of Korea.
| | - Tahmineh Mahmoudi
- School of Semiconductor and Chemical Engineering, Nanomaterials Processing Research Center, Chonbuk National University, 567 Baekjedaero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Republic of Korea
| | - Min-Sang Ahn
- School of Semiconductor and Chemical Engineering, Nanomaterials Processing Research Center, Chonbuk National University, 567 Baekjedaero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Republic of Korea
| | - Yoon-Bong Hahn
- School of Semiconductor and Chemical Engineering, Nanomaterials Processing Research Center, Chonbuk National University, 567 Baekjedaero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Republic of Korea.
| |
Collapse
|
48
|
Abstract
Since its discovery in 1988, B-type natriuretic peptide (BNP) has been recognized as a powerful cardiovascular biomarker for a number of disease states, specifically heart failure. Concurrent with such a discovery, much effort has been allocated to the precise monitoring of physiological BNP levels. Thus, it can be used to guide the therapy of heart failure and determine the patient's stage of disease. Thus, we discuss in this article BNP as a potent biomarker. Subsequently, we will review the progress of biosensing devices as they could be applied to monitor BNP levels as assays, benchtop biosensors and implantable biosensors. The analytical characteristics of commercially available BNP assays are presented. Still emerging as a field, we define four obstacles that present opportunity for the future development of implantable biosensor: foreign body response, sensor renewability, sensitivity and selectivity.
Collapse
|
49
|
Xing Y, Dittrich PS. One-Dimensional Nanostructures: Microfluidic-Based Synthesis, Alignment and Integration towards Functional Sensing Devices. SENSORS 2018; 18:s18010134. [PMID: 29303990 PMCID: PMC5795670 DOI: 10.3390/s18010134] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 12/29/2017] [Accepted: 12/31/2017] [Indexed: 12/23/2022]
Abstract
Microfluidic-based synthesis of one-dimensional (1D) nanostructures offers tremendous advantages over bulk approaches e.g., the laminar flow, reduced sample consumption and control of self-assembly of nanostructures. In addition to the synthesis, the integration of 1D nanomaterials into microfluidic chips can enable the development of diverse functional microdevices. 1D nanomaterials have been used in applications such as catalysts, electronic instrumentation and sensors for physical parameters or chemical compounds and biomolecules and hence, can be considered as building blocks. Here, we outline and critically discuss promising strategies for microfluidic-assisted synthesis, alignment and various chemical and biochemical applications of 1D nanostructures. In particular, the use of 1D nanostructures for sensing chemical/biological compounds are reviewed.
Collapse
Affiliation(s)
- Yanlong Xing
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e. V, 12489 Berlin, Germany.
| | - Petra S Dittrich
- Department of Biosystems Science and Engineering, ETH Zürich, 4058 Basel, Switzerland.
| |
Collapse
|
50
|
Lee JK, Wang IS, Huang CH, Chen YF, Huang NT, Lin CT. Pre-Clinical Tests of an Integrated CMOS Biomolecular Sensor for Cardiac Diseases Diagnosis. SENSORS 2017; 17:s17122733. [PMID: 29186872 PMCID: PMC5751442 DOI: 10.3390/s17122733] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 11/22/2017] [Accepted: 11/24/2017] [Indexed: 11/28/2022]
Abstract
Coronary artery disease and its related complications pose great threats to human health. In this work, we aim to clinically evaluate a CMOS field-effect biomolecular sensor for cardiac biomarkers, cardiac-specific troponin-I (cTnI), N-terminal prohormone brain natriuretic peptide (NT-proBNP), and interleukin-6 (IL-6). The CMOS biosensor is implemented via a standard commercialized 0.35 μm CMOS process. To validate the sensing characteristics, in buffer conditions, the developed CMOS biosensor has identified the detection limits of IL-6, cTnI, and NT-proBNP as being 45 pM, 32 pM, and 32 pM, respectively. In clinical serum conditions, furthermore, the developed CMOS biosensor performs a good correlation with an enzyme-linked immuno-sorbent assay (ELISA) obtained from a hospital central laboratory. Based on this work, the CMOS field-effect biosensor poses good potential for accomplishing the needs of a point-of-care testing (POCT) system for heart disease diagnosis.
Collapse
Affiliation(s)
- Jen-Kuang Lee
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan.
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei 10048, Taiwan.
- Telehealth Center, National Taiwan University Hospital, Taipei 10048, Taiwan.
- Department of Laboratory Medicine, National Taiwan University Hospital, Taipei 10048, Taiwan.
| | - I-Shun Wang
- Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan.
| | - Chi-Hsien Huang
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei 24301, Taiwan.
| | - Yih-Fan Chen
- Insisute of Biophotonics, National Yang-Ming University, Taipei 11221, Taiwan.
| | - Nien-Tsu Huang
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan.
| | - Chih-Ting Lin
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan.
- Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan.
| |
Collapse
|