1
|
Naghdi E, Reinau ME, Krogh TN, Neusüß C. Chemical Mobilization-Based Capillary Isoelectric Focusing-Mass Spectrometry Using the nanoCEasy Interface for Pharmaceutical Protein Analysis. Anal Chem 2024. [PMID: 39072373 DOI: 10.1021/acs.analchem.4c02441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/30/2024]
Abstract
Capillary isoelectric focusing (CIEF) coupled with electrospray ionization mass spectrometry (ESI-MS) is regarded as an outstanding approach for protein and proteoform analysis, combining a high-resolution separation technique and an enhanced detection technique. The few so-far developed CIEF-ESI-MS approaches exhibit limitations regarding sensitivity and separation performance. Here, we report a new generic methodology for CIEF-ESI-MS based on chemical mobilization, leading to highly efficient separation. This new integrated methodology relies on exchanging catholyte, initially introduced in the nanoCEasy interface in the focusing step, with sheath liquid (SL) in order to chemically mobilize the analytes into the ESI-MS system. The CIEF-MS method is evaluated by separation of a peptide set, model proteins, and monoclonal antibody charge variants. The effect of various parameters including master mixture composition, field strength, catholyte, SL composition, focusing time, and capillary conditions is optimized and discussed. Excellent separation performance can be achieved with a pI resolution down to 0.1 pH unit. The mobilization reproducibility is demonstrated with "migration time" RSDs below 10%. Additionally, the chemical mobilization is compared with the pressure assistance-chemical mobilization method, demonstrating that even a small pressure causes a strong decrease in separation performance, which clearly indicates the benefit of the chemical mobilization-based method. The applicability and separation power of the developed method are further exhibited by separation of Fc-conjugated insulins (mass = 62 kDa) differing in only one amino acid.
Collapse
Affiliation(s)
- Elahe Naghdi
- Department of Chemical Engineering and Industrial Chemistry, Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | - Marika Ejby Reinau
- Novo Nordisk A/S, Global Research Technologies, DK-2760 Maaloev, Denmark
| | | | | |
Collapse
|
2
|
Xu T, Wang Q, Wang Q, Sun L. Mass spectrometry-intensive top-down proteomics: an update on technology advancements and biomedical applications. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:4664-4682. [PMID: 38973469 PMCID: PMC11257149 DOI: 10.1039/d4ay00651h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 06/25/2024] [Indexed: 07/09/2024]
Abstract
Proteoforms are all forms of protein molecules from the same gene because of variations at the DNA, RNA, and protein levels, e.g., alternative splicing and post-translational modifications (PTMs). Delineation of proteins in a proteoform-specific manner is crucial for understanding their biological functions. Mass spectrometry (MS)-intensive top-down proteomics (TDP) is promising for comprehensively characterizing intact proteoforms in complex biological systems. It has achieved substantial progress in technological development, including sample preparation, proteoform separations, MS instrumentation, and bioinformatics tools. In a single TDP study, thousands of proteoforms can be identified and quantified from a cell lysate. It has also been applied to various biomedical research to better our understanding of protein function in regulating cellular processes and to discover novel proteoform biomarkers of diseases for early diagnosis and therapeutic development. This review covers the most recent technological development and biomedical applications of MS-intensive TDP.
Collapse
Affiliation(s)
- Tian Xu
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| | - Qianjie Wang
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| | - Qianyi Wang
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| |
Collapse
|
3
|
Li Y, Miao S, Tan J, Zhang Q, Chen DDY. Capillary Electrophoresis: A Three-Year Literature Review. Anal Chem 2024; 96:7799-7816. [PMID: 38598751 DOI: 10.1021/acs.analchem.4c00857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2024]
Affiliation(s)
- Yueyang Li
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Siyu Miao
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Jiahua Tan
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Qi Zhang
- School of Pharmacy, Jiangsu University, Zhenjiang, Jiangsu 212013, P. R. China
| | - David Da Yong Chen
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| |
Collapse
|
4
|
Schairer J, Plathe F, Hudelmaier S, Belau E, Pengelley S, Kruse L, Neusüß C. Ion mobility in gas and liquid phases: How much orthogonality is obtained in capillary electrophoresis-ion mobility-mass spectrometry? Electrophoresis 2024; 45:735-742. [PMID: 38085142 DOI: 10.1002/elps.202300210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/16/2023] [Accepted: 11/30/2023] [Indexed: 04/28/2024]
Abstract
Ion mobility-mass spectrometry (IM-MS) is an ever-evolving tool to separate ions in the gas phase according to electrophoretic mobility with subsequent mass determination. CE is rarely coupled to IM-MS, possibly due to similar separation mechanisms based on electrophoretic mobility. Here, we investigate the orthogonality of CE and ion mobility (IM) by analyzing a complex peptide mixture (tryptic digest of HeLa proteins) with trapped ion mobility mass spectrometry (TIMS-MS). Using the nanoCEasy interface, excellent sensitivity was achieved by identifying thousands of peptides and achieving a peak capacity of 7500 (CE: 203-323 in a 150 cm long capillary, IM: 27-31). Plotting CE versus mass and CE versus (inverse) mobility, a clear grouping in curved striped patterns is observed according to the charge-to-size and mass-to-charge ratios. The peptide charge in the acidic background electrolyte can be estimated from the number of basic amino acids, with a few exceptions where neighboring effects reduce the positive charge. A surprisingly high orthogonality of CE and IM is observed, which is obviously caused by solvation effects leading to different charges and sizes in the liquid phase compared to the gas phase. A high orthogonality of CE and ion mobility is expected to be observed for other peptide samples as well as other substance classes, making CE-IM-MS a promising tool for various applications.
Collapse
Affiliation(s)
- Jasmin Schairer
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Faculty of Science, University of Tübingen, Tübingen, Germany
| | | | | | | | | | - Lena Kruse
- Faculty of Chemistry, Aalen University, Aalen, Germany
| | | |
Collapse
|
5
|
Schairer J, Römer J, Lang D, Neusüß C. CE-MS/MS and CE-timsTOF to separate and characterize intramolecular disulfide bridges of monoclonal antibody subunits and their application for the assessment of subunit reduction protocols. Anal Bioanal Chem 2024; 416:1599-1612. [PMID: 38296860 PMCID: PMC10899284 DOI: 10.1007/s00216-024-05161-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/15/2024] [Accepted: 01/17/2024] [Indexed: 02/02/2024]
Abstract
Characterization at the subunit level enables detailed mass spectrometric characterization of posttranslational modifications (PTMs) of monoclonal antibodies (mAbs). The implemented reduction often leaves the intramolecular disulfide bridges intact. Here, we present a capillary electrophoretic (CE) method based on a neutral-coated capillary for the separation of immunoglobulin G-degrading enzyme of Streptococcus pyogenes (IdeS) digested and reduced mAb subunits followed by mass spectrometry (MS), MS/MS identification, and trapped ion mobility mass spectrometry (timsTOF). Our CE approach enables the separation of (i) different subunit moieties, (ii) various reduction states, and (iii) positional isomers of these partly reduced subunit moieties. The location of the remaining disulfide bridges can be determined by middle-down electron transfer higher energy collisional dissociation (EThcD) experiments. All these CE-separated variants show differences in ion mobility in the timsTOF measurements. Applying the presented CE-MS/MS method, reduction parameters such as the use of chaotropic salts were studied. For the investigated antibodies, urea improved the subunit reduction significantly, whereas guanidine hydrochloride (GuHCl) leads to multiple signals of the same subunit in the CE separation. The presented CE-MS method is a powerful tool for the disulfide-variant characterization of mAbs on the subunit level. It enables understanding disulfide bridge reduction processes in antibodies and potentially other proteins.
Collapse
Affiliation(s)
- Jasmin Schairer
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Faculty of Science, University of Tübingen, Tübingen, Germany
| | | | | | | |
Collapse
|
6
|
Bouvarel T, Camperi J, Guillarme D. Multi-dimensional technology - Recent advances and applications for biotherapeutic characterization. J Sep Sci 2024; 47:e2300928. [PMID: 38471977 DOI: 10.1002/jssc.202300928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/23/2024] [Accepted: 01/24/2024] [Indexed: 03/14/2024]
Abstract
This review provides an overview of the latest advancements and applications in multi-dimensional liquid chromatography coupled with mass spectrometry (mD-LC-MS), covering aspects such as inter-laboratory studies, digestion strategy, trapping column, and multi-level analysis. The shift from an offline to an online workflow reduces sample processing artifacts, analytical variability, analysis time, and the labor required for data acquisition. Over the past few years, this technique has demonstrated sufficient maturity for application across a diverse range of complex products. Moreover, there is potential for this strategy to evolve into an integrated process analytical technology tool for the real-time monitoring of monoclonal antibody quality. This review also identifies emerging trends, including its application to new modalities, the possibility of evaluating biological activity within the mD-LC set-up, and the consideration of multi-dimensional capillary electrophoresis as an alternative to mD-LC. As mD-LC-MS continues to evolve and integrate emerging trends, it holds the potential to shape the next generation of analytical tools, offering exciting possibilities for enhanced characterization and monitoring of complex biopharmaceutical products.
Collapse
Affiliation(s)
- Thomas Bouvarel
- Protein Analytical Chemistry, Genentech, South San Francisco, California, USA
| | - Julien Camperi
- Cell Therapy Engineering and Development, Genentech, South San Francisco, California, USA
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland
| |
Collapse
|
7
|
Schwenzer AK, Kruse L, Jooß K, Neusüß C. Capillary electrophoresis-mass spectrometry for protein analyses under native conditions: Current progress and perspectives. Proteomics 2024; 24:e2300135. [PMID: 37312401 DOI: 10.1002/pmic.202300135] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 05/16/2023] [Accepted: 05/23/2023] [Indexed: 06/15/2023]
Abstract
Native mass spectrometry is a rapidly emerging technique for fast and sensitive structural analysis of protein constructs, maintaining the protein higher order structure. The coupling with electromigration separation techniques under native conditions enables the characterization of proteoforms and highly complex protein mixtures. In this review, we present an overview of current native CE-MS technology. First, the status of native separation conditions is described for capillary zone electrophoresis (CZE), affinity capillary electrophoresis (ACE), and capillary isoelectric focusing (CIEF), as well as their chip-based formats, including essential parameters such as electrolyte composition and capillary coatings. Further, conditions required for native ESI-MS of (large) protein constructs, including instrumental parameters of QTOF and Orbitrap systems, as well as requirements for native CE-MS interfacing are presented. On this basis, methods and applications of the different modes of native CE-MS are summarized and discussed in the context of biological, medical, and biopharmaceutical questions. Finally, key achievements are highlighted and concluded, while remaining challenges are pointed out.
Collapse
Affiliation(s)
| | - Lena Kruse
- Department of Chemistry, Aalen University, Aalen, Germany
| | - Kevin Jooß
- Department of Chemistry and Molecular Biosciences, the Chemistry of Life Processes Institute, and the Proteomics Center of Excellence, Northwestern University, Evanston, Illinois, USA
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | | |
Collapse
|
8
|
Kašička V. Recent developments in capillary and microchip electroseparations of peptides (2021-mid-2023). Electrophoresis 2024; 45:165-198. [PMID: 37670208 DOI: 10.1002/elps.202300152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 08/22/2023] [Accepted: 08/22/2023] [Indexed: 09/07/2023]
Abstract
This review article brings a comprehensive survey of developments and applications of high-performance capillary and microchip electromigration methods (zone electrophoresis in a free solution or in sieving media, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography) for analysis, micropreparation, and physicochemical characterization of peptides in the period from 2021 up to ca. the middle of 2023. Progress in the study of electromigration properties of peptides and various aspects of their analysis, such as sample preparation, adsorption suppression, electroosmotic flow regulation, and detection, are presented. New developments in the particular capillary electromigration methods are demonstrated, and several types of their applications are reported. They cover qualitative and quantitative analysis of synthetic or isolated peptides and determination of peptides in complex biomatrices, peptide profiling of biofluids and tissues, and monitoring of chemical and enzymatic reactions and physicochemical changes of peptides. They include also amino acid and sequence analysis of peptides, peptide mapping of proteins, separation of stereoisomers of peptides, and their chiral analyses. In addition, micropreparative separations and physicochemical characterization of peptides and their interactions with other (bio)molecules by the above CE methods are described.
Collapse
Affiliation(s)
- Václav Kašička
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Prague, Czechia
| |
Collapse
|
9
|
Hou M, Sun S, Zhu Y, Yu Q. A 3D-printed sub-atmospheric pressure electrospray ionization source for robust, facile, and flexible mass spectrometry analysis. Anal Bioanal Chem 2023; 415:6441-6448. [PMID: 37644320 DOI: 10.1007/s00216-023-04920-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 08/17/2023] [Accepted: 08/22/2023] [Indexed: 08/31/2023]
Abstract
The operation and performance of electrospray ionization (ESI) is affected by the surrounding environment. In this study, a compact sub-atmospheric pressure ESI (SAP-ESI) source was designed and fabricated using the 3D printing method. This source has a simple structure and is easy to operate, as the sample solution and auxiliary gas are continuously sucked into the source through the pressure difference. The compact and enclosed ionization chamber can reduce the fluctuation of the surrounding gas flow to ensure a remarkably stable (< 3%) electrospray. Moreover, the source can offer variable SAP conditions for ESI analysis. The yield of analyte ions increases with decreasing pressure, while the production of background ions is suppressed under these conditions. In the analysis of protein samples, SAP-ESI can increase the yield and charge state of ions, which may be due to the reduction of proton transfer between charged proteins and surrounding gas. The SAP-ESI source was then used to continuously monitor the extract aqueous solution of tea leaves, and to detect the carbendazim residues on the apple surface by coupling with the liquid extraction surface analysis technique. Experimental results demonstrate that the developed SAP-ESI is a stable, practical, and versatile ionization technique.
Collapse
Affiliation(s)
- Mulang Hou
- Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Shuang Sun
- Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Yanping Zhu
- Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Quan Yu
- Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China.
| |
Collapse
|
10
|
Gebretsadik H, Kahsay G, Adams E, Van Schepdael A. A comprehensive review of capillary electrophoresis-based techniques for erythropoietin isoforms analysis. J Chromatogr A 2023; 1708:464331. [PMID: 37660565 DOI: 10.1016/j.chroma.2023.464331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/18/2023] [Accepted: 08/24/2023] [Indexed: 09/05/2023]
Abstract
Different CE techniques have been used to analyze erythropoietin. These techniques have been shown to be effective in differentiating and quantifying erythropoietin isoforms, including natural and recombinant origins. This review provides a comprehensive overview of various capillary electrophoresis-based techniques used for the analysis of erythropoietin isoforms. The importance of erythropoietin in clinical practice and the necessity for the accurate analysis of its isoforms are first discussed. Various techniques that have been used for erythropoietin isoform analysis are then described. The main body of the review focuses on the different capillary electrophoresis-based methods that have been developed for erythropoietin isoform analysis, including capillary zone electrophoresis and capillary isoelectric focusing. The advantages and drawbacks of each method as well as their applications are discussed. Suggestions into the future directions of the area are also described.
Collapse
Affiliation(s)
- Hailekiros Gebretsadik
- KU Leuven - University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Getu Kahsay
- KU Leuven - University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Erwin Adams
- KU Leuven - University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Ann Van Schepdael
- KU Leuven - University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium.
| |
Collapse
|
11
|
Naumann L, Haun A, Höchsmann A, Mohr M, Novák M, Flottmann D, Neusüß C. Augmented region of interest for untargeted metabolomics mass spectrometry (AriumMS) of multi-platform-based CE-MS and LC-MS data. Anal Bioanal Chem 2023:10.1007/s00216-023-04715-6. [PMID: 37225900 DOI: 10.1007/s00216-023-04715-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/16/2023] [Accepted: 04/20/2023] [Indexed: 05/26/2023]
Abstract
In mass spectrometry (MS)-based metabolomics, there is a great need to combine different analytical separation techniques to cover metabolites of different polarities and apply appropriate multi-platform data processing. Here, we introduce AriumMS (augmented region of interest for untargeted metabolomics mass spectrometry) as a reliable toolbox for multi-platform metabolomics. AriumMS offers augmented data analysis of several separation techniques utilizing a region-of-interest algorithm. To demonstrate the capabilities of AriumMS, five datasets were combined. This includes three newly developed capillary electrophoresis (CE)-Orbitrap MS methods using the recently introduced nanoCEasy CE-MS interface and two hydrophilic interaction liquid chromatography (HILIC)-Orbitrap MS methods. AriumMS provides a novel mid-level data fusion approach for multi-platform data analysis to simplify and speed up multi-platform data processing and evaluation. The key feature of AriumMS lies in the optimized data processing strategy, including parallel processing of datasets and flexible parameterization for processing of individual separation methods with different peak characteristics. As a case study, Saccharomyces cerevisiae (yeast) was treated with a growth inhibitor, and AriumMS successfully differentiated the metabolome based on the augmented multi-platform CE-MS and HILIC-MS investigation. As a result, AriumMS is proposed as a powerful tool to improve the accuracy and selectivity of metabolome analysis through the integration of several HILIC-MS/CE-MS techniques.
Collapse
Affiliation(s)
- Lukas Naumann
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany
| | - Adrian Haun
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany
| | - Alisa Höchsmann
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany
| | - Michael Mohr
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany
| | - Martin Novák
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany
| | - Dirk Flottmann
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany
| | - Christian Neusüß
- Department of Chemistry, Aalen University, Beethovenstraße 1, 73430, Aalen, Germany.
| |
Collapse
|
12
|
Schlecht J, Moritz B, Kiessig S, Neusüß C. Characterization of therapeutic mAb charge heterogeneity by iCIEF coupled to mass spectrometry (iCIEF-MS). Electrophoresis 2023; 44:540-548. [PMID: 36148605 DOI: 10.1002/elps.202200170] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/27/2022] [Accepted: 08/31/2022] [Indexed: 11/07/2022]
Abstract
Imaged capillary isoelectric focusing (iCIEF) has emerged as an important technique for therapeutic monoclonal antibody (mAb) charge heterogeneity analysis in the biopharmaceutical context, providing imaged detection and quantitation by UV without a mobilization step. Besides quantitation, the characterization of separated charge variants ideally directly by online electrospray ionization-mass spectrometry (ESI-MS) is crucial to ensure product quality, safety, and efficacy. Straightforward direct iCIEF-MS coupling combining high separation efficiency and quantitative results of iCIEF with the characterization power of MS enables deep characterization of mAb charge variants. A short technical setup and optimized methodical parameters (30 nl/min mobilization rate, 2%-4% ampholyte concentration, 0.5-2 mg/ml sample concentration) allow successful mAb charge variant peak assignment from iCIEF to MS. Despite a loss of separation resolution during the transfer, separated intact mAb charge variants, including deamidation as well as major and minor glycoforms even from low abundant charge variants, could be characterized by online ESI-MS with high precision. The presented setup provides a large potential for mAb charge heterogeneity characterization in biopharmaceutical applications.
Collapse
Affiliation(s)
- Johannes Schlecht
- Department of Chemistry, Aalen University, Aalen, Germany.,Department of Pharmaceutical and Medicinal Chemistry, Friedrich Schiller University Jena, Jena, Germany
| | | | | | | |
Collapse
|
13
|
Schlecht J, Jooß K, Moritz B, Kiessig S, Neusüß C. Two-Dimensional Capillary Zone Electrophoresis-Mass Spectrometry: Intact mAb Charge Variant Separation Followed by Peptide Level Analysis Using In-Capillary Digestion. Anal Chem 2023; 95:4059-4066. [PMID: 36800441 DOI: 10.1021/acs.analchem.2c04578] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Characterization of charge heterogeneity is an essential pillar for pharmaceutical development and quality control of therapeutic monoclonal antibodies (mAbs). The highly selective and commonly applied capillary zone electrophoresis (CZE) method containing high amounts of ε-aminocaproic acid (EACA) provides a detailed and robust charge heterogeneity profile of intact mAb variants. Nevertheless, the exact location of protein modifications within these charge profiles remains ambiguous. Electrospray ionization mass spectrometry (ESI-MS) is a promising tool for this purpose; however, EACA is incompatible with electrospray. In this context, we present a two-dimensional CZE-CZE-MS system to combine efficient charge variant separation of intact mAbs with subsequent peptide analysis after in-capillary digestion of selected charge variants. The first dimension is based on a generic CZE(EACA) method in a fused silica capillary. In the second dimension, a neutral-coated capillary is used for in-capillary reduction and digestion with Tris(2-carboxyethyl)phosphine (TCEP) and pepsin, followed by CZE separation and MS/MS-characterization of the resulting peptides. The setup is demonstrated using stressed and nonstressed mAbs where peaks of basic, main, and acidic variants were transferred in a heart-cut fashion, digested, and characterized on the peptide level. Sequence coverages of more than 90% were obtained for heavy chain (HC) and light chain (LC) for four different mAbs, including low-abundance variants (<2% of the main peak). Frequently observed modifications (deamidation, oxidation, etc.) could be detected and localized. This study demonstrates a proof-of-concept for identification and localization of protein modifications from CZE charge heterogeneity profiles and, in this way, is expected to support the development and quality control testing of protein pharmaceuticals.
Collapse
Affiliation(s)
- Johannes Schlecht
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany.,Department of Pharmaceutical and Medicinal Chemistry, Friedrich Schiller University Jena, 07743 Jena, Germany
| | - Kevin Jooß
- Departments of Chemistry and Molecular Biosciences, the Chemistry of Life Processes Institute, and the Proteomics Center of Excellence, Northwestern University, Evanston, Illinois 60208, United States
| | - Bernd Moritz
- F. Hoffmann La-Roche Ltd., Grenzacherstraße 124, 4058 Basel, Switzerland
| | - Steffen Kiessig
- F. Hoffmann La-Roche Ltd., Grenzacherstraße 124, 4058 Basel, Switzerland
| | - Christian Neusüß
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany
| |
Collapse
|
14
|
Novel developments in capillary electrophoresis miniaturization, sampling, detection and portability: An overview of the last decade. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
15
|
Zhang W, Xiang Y, Xu W. Probing protein higher-order structures by native capillary electrophoresis-mass spectrometry. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Recent advances in the hyphenation of electromigration techniques with mass spectrometry. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
17
|
Elshamy YS, Strein TG, Holland LA, Li C, DeBastiani A, Valentine SJ, Li P, Lucas JA, Shaffer TA. Nanoflow Sheath Voltage-Free Interfacing of Capillary Electrophoresis and Mass Spectrometry for the Detection of Small Molecules. Anal Chem 2022; 94:11329-11336. [PMID: 35913997 PMCID: PMC9387528 DOI: 10.1021/acs.analchem.2c02074] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Coupling capillary electrophoresis (CE) to mass spectrometry (MS) is a powerful strategy to leverage a high separation efficiency with structural identification. Traditional CE-MS interfacing relies upon voltage to drive this process. Additionally, sheathless interfacing requires that the electrophoresis generates a sufficient volumetric flow to sustain the ionization process. Vibrating sharp-edge spray ionization (VSSI) is a new method to interface capillary electrophoresis to mass analyzers. In contrast to traditional interfacing, VSSI is voltage-free, making it straightforward for CE and MS. New nanoflow sheath CE-VSSI-MS is introduced in this work to reduce the reliance on the separation flow rate to facilitate the transfer of analyte to the MS. The nanoflow sheath VSSI spray ionization functions from 400 to 900 nL/min. Using the new nanoflow sheath reported here, volumetric flow rate through the separation capillary is less critical, allowing the use of a small (i.e., 20 to 25 μm) inner diameter separation capillary and enabling the use of higher separation voltages and faster analysis. Moreover, the use of a nanoflow sheath enables greater flexibility in the separation conditions. The nanoflow sheath is operated using aqueous solutions in the background electrolyte and in the sheath, demonstrating the separation can be performed under normal and reversed polarity in the presence or absence of electroosmotic flow. This includes the use of a wider pH range as well. The versatility of nanoflow sheath CE-VSSI-MS is demonstrated by separating cationic, anionic, and zwitterionic molecules under a variety of separation conditions. The detection sensitivity observed with nanoflow sheath CE-VSSI-MS is comparable to that obtained with sheathless CE-VSSI-MS as well as CE-MS separations with electrospray ionization interfacing. A bare fused silica capillary is used to separate cationic β-blockers with a near-neutral background electrolyte at concentrations ranging from 1.0 nM to 1.0 μM. Under acidic conditions, 13 amino acids are separated with normal polarity at a concentration ranging from 0.25 to 5 μM. Finally, separations of anionic compounds are demonstrated using reversed polarity under conditions of suppressed electroosmotic flow through the use of a semipermanent surface coating. With a near-neutral separation electrolyte, anionic nonsteroidal anti-inflammatory drugs are detected over a concentration range of 0.1 to 5.0 μM.
Collapse
Affiliation(s)
- Yousef S Elshamy
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Timothy G Strein
- Department of Chemistry, Bucknell University, Lewisburg, Pennsylvania 17837, United States
| | - Lisa A Holland
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Anthony DeBastiani
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Stephen J Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - John A Lucas
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| | - Tyler A Shaffer
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26505, United States
| |
Collapse
|
18
|
MA Y, HU Y, ZHENG L, CHEN L, ZHAO X, QU F. Annual review of capillary electrophoresis technology in 2021. Se Pu 2022; 40:591-599. [PMID: 35791597 PMCID: PMC9404112 DOI: 10.3724/sp.j.1123.2022.03040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
该文为2021年毛细管电泳(capillary electrophoresis, CE)技术年度回顾。归纳总结了以“capillary electrophoresis-mass spectrometry”或“capillary isoelectric focusing”或“micellar electrokinetic chromatography”或“capillary electrophoresis”为关键词在ISI Web of Science数据库中进行主题检索(排除“capillary electrochromatography”“microchip”和“capillary monolithic column”)得到的2021年CE技术相关研究论文291篇,以及中文期刊《色谱》和《分析化学》中相关研究论文9篇。重点介绍了影响因子(IF)≥10.0的Coordination Chemistry Reviews, Angewandte Chemie-International Edition, Nature Protocols, TrAC-Trends in Analytical Chemistry, Signal Transduction and Targeted Therapy发表的7篇论文;以及影响因子5~10之间的代表性期刊Analytical Chemistry, Analytica Chimica Acta, Talanta和Food Chemistry的42篇论文;对影响因子小于5但CE技术报道较为集中的Journal of Chromatography A和Electrophoresis,国内重要的中文期刊《色谱》和《分析化学》中的代表性工作进行了概述。该文根据国际通用学术水平评价指标之一的影响因子选择期刊,结合期刊发表CE论文代表性工作进行介绍,便于读者快速了解毛细管电泳技术在过去一年的重要研究进展。
Collapse
|
19
|
Naumann L, Schlossbauer P, Klingler F, Hesse F, Otte K, Neusüß C. High throughput glycosylation analysis of intact monoclonal antibodies by mass spectrometry coupled with capillary electrophoresis and liquid chromatography. J Sep Sci 2022; 45:2034-2044. [PMID: 35044720 DOI: 10.1002/jssc.202100865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 01/05/2022] [Accepted: 01/08/2022] [Indexed: 11/07/2022]
Abstract
The analysis of monoclonal antibodies glycosylation is a crucial quality control attribute of biopharmaceutical drugs. High throughput screening approaches for antibody glycoform analysis are required in various stages of process optimization. Here, we present high throughput screening suitable mass spectrometry-based workflows for the analysis of intact antibody glycosylation out of cell supernatants. Capillary electrophoresis and liquid chromatography were coupled with quadrupole time-of-flight MS or Orbitrap MS. Both separation methods offer fast separation (10-15 min) and the capability to prevent the separated cell supernatant matrix to enter the MS by post-separation valving. Both MS instruments provide comparable results and both are sufficient to determine the glycosylation pattern of the five major glycoforms of the measured antibodies. However, the Orbitrap yields higher sensitivity of 25 μg/mL (CE-nanoCEasy-Orbitrap MS) and 5 μg/mL (LC-Orbitrap MS). Data processing was optimized for a faster processing and easier detection of low abundant glycoforms based on averaged charge-deconvoluted mass spectra. This approach combines a non-target glycoform analysis, while yielding the same glycosylation pattern as the traditional approach based on extracted ion traces. The presented methods enable the high throughput screening of the glycosylation pattern of antibodies down to low μg/mL-range out of cell supernatant without any sample preparation. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Lukas Naumann
- Department of Chemistry, Aalen University, Beethovenstraße 1, Aalen, 73430, Germany
| | - Patrick Schlossbauer
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Florian Klingler
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Friedemann Hesse
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Kerstin Otte
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Christian Neusüß
- Department of Chemistry, Aalen University, Beethovenstraße 1, Aalen, 73430, Germany
| |
Collapse
|
20
|
Salzer L, Stolz A, Dhellemmes L, Höchsmann A, Leclercq L, Cottet H, Neusüß C. Successive Multiple Ionic-Polymer Layer Coatings for Intact Protein Analysis by Capillary Zone Electrophoresis-Mass Spectrometry: Application to Hemoglobin Analysis. Methods Mol Biol 2022; 2531:69-76. [PMID: 35941479 DOI: 10.1007/978-1-0716-2493-7_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Adsorption of analytes, e.g., proteins, often interfere with separation in CE, due to the relatively large surface of the narrow capillary. Coatings often are applied to prevent adsorption and to determine the electroosmotic flow (EOF), which is of major importance for the separation in CE. Successive multiple ionic-polymer layer (SMIL) coatings are frequently used for protein analysis in capillary electrophoresis resulting in high separation efficiency and repeatability. Here, the coating procedure of a five-layer SMIL coating is described using quaternized diethylaminoethyl dextran (DEAEDq) as polycation and poly(methacrylic acid) (PMA) as polyanion. Depending on the analyte, different polyions may be used to increase separation efficiency. However, the coating procedure remains the same.To demonstrate the applicability of SMIL coatings in CE-MS, human hemoglobin was measured in a BGE containing 2 M acetic acid. DEAEDq-PMA coating was found to be the most suitable for hemoglobin analysis due to relatively low reversed electroosmotic mobility leading to increased electrophoretic resolution of closely related proteoforms. Thereby, not only alpha and beta subunit of the hemoglobin could be separated, but also positional isoforms of glycated and carbamylated species were separated within 24 min.
Collapse
Affiliation(s)
- Liesa Salzer
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Analytical BioGeoChemistry (BGC), Helmholtz Zentrum München, Neuherberg, Germany
| | | | - Laura Dhellemmes
- Institut des Biomolécules Max Mousseron, UMR CNRS, Université de Montpellier, Montpellier, France
| | | | - Laurent Leclercq
- Institut des Biomolécules Max Mousseron, UMR CNRS, Université de Montpellier, Montpellier, France
| | - Hervé Cottet
- Institut des Biomolécules Max Mousseron, UMR CNRS, Université de Montpellier, Montpellier, France
| | | |
Collapse
|
21
|
Characterisation of a new online nanoLC-CZE-MS platform and application for the glycosylation profiling of alpha-1-acid glycoprotein. Anal Bioanal Chem 2021; 414:1745-1757. [PMID: 34881393 PMCID: PMC8791864 DOI: 10.1007/s00216-021-03814-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/19/2021] [Accepted: 11/30/2021] [Indexed: 11/22/2022]
Abstract
The ever-increasing complexity of biological samples to be analysed by mass spectrometry has led to the necessity of sophisticated separation techniques, including multidimensional separation. Despite a high degree of orthogonality, the coupling of liquid chromatography (LC) and capillary zone electrophoresis (CZE) has not gained notable attention in research. Here, we present a heart-cut nanoLC-CZE-ESI-MS platform to analyse intact proteins. NanoLC and CZE-MS are coupled using a four-port valve with an internal nanoliter loop. NanoLC and CZE-MS conditions were optimised independently to find ideal conditions for the combined setup. The valve setup enables an ideal transfer efficiency between the dimensions while maintaining good separation conditions in both dimensions. Due to the higher loadability, the nanoLC-CZE-MS setup exhibits a 280-fold increased concentration sensitivity compared to CZE-MS. The platform was used to characterise intact human alpha-1-acid glycoprotein (AGP), an extremely heterogeneous N-glycosylated protein. With the nanoLC-CZE-MS approach, 368 glycoforms can be assigned at a concentration of 50 μg/mL as opposed to the assignment of only 186 glycoforms from 1 mg/mL by CZE-MS. Additionally, we demonstrate that glycosylation profiling is accessible for dried blood spot analysis (25 μg/mL AGP spiked), indicating the general applicability of our setup to biological matrices. The combination of high sensitivity and orthogonal selectivity in both dimensions makes the here-presented nanoLC-CZE-MS approach capable of detailed characterisation of intact proteins and their proteoforms from complex biological samples and in physiologically relevant concentrations.
Collapse
|