1
|
Meng L, Zhang Y, Wang J, Zhou B, Shi J, Zhang H. Metal organic framework-derived CuO/Cu 2O polyhedron-CdS quantum dots double Z-scheme heterostructure for cathodic photoelectrochemical detection of Hg 2+ in food and environment. Food Chem 2024; 450:139261. [PMID: 38657344 DOI: 10.1016/j.foodchem.2024.139261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 04/02/2024] [Accepted: 04/03/2024] [Indexed: 04/26/2024]
Abstract
This study employed an innovative copper oxide/cuprous oxide (CuO/Cu2O) polyhedron‑cadmium sulphide quantum dots (CdS QDs) double Z-scheme heterostructure as a matrix for the cathodic PEC determination of mercury ions (Hg2+). First, the CuO/Cu2O polyhedral composite was prepared by calcining a copper-based metal organic framework (Cu-MOF). Subsequently, the amino-modified CuO/Cu2O was integrated with mercaptopropionic acid (MPA)-capped CdS QDs to form a CuO/Cu2O polyhedron-CdS QDs double Z-scheme heterostructure, producing a strong cathodic photocurrent. Importantly, this heterostructure exhibited a specifically reduced photocurrent for Hg2+ when using CdS QDs as Hg2+-recognition probe. This was attributed to the extreme destruction of the double Z-scheme heterostructure and the in situ formation of the CuO/Cu2O-CdS/HgS heterostructure. Besides, p-type HgS competed with the matrix for electron acceptors, further decreasing the photocurrent. Consequently, Hg2+ was sensitively assayed, with a low detection limit (0.11 pM). The as-prepared PEC sensor was also used to analyse Hg2+ in food and the environment.
Collapse
Affiliation(s)
- Leixia Meng
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo 454000, PR China.
| | - Yu Zhang
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo 454000, PR China
| | - Jinlong Wang
- College of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo 454000, PR China
| | - Bingxin Zhou
- School of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo 454000, PR China
| | - Jianjun Shi
- School of Chemical Engineering, Anhui University of Science and Technology, Huainan 232001, PR China.
| | - Huawei Zhang
- School of Electronics and Information, Zhengzhou University of Light Industry, Zhengzhou 450002, China
| |
Collapse
|
2
|
Lu L, Zeng R, Lin Q, Huang X, Tang D. Cation Exchange Reaction-Mediated Photothermal and Polarity-Switchable Photoelectrochemical Dual-Readout Biosensor. Anal Chem 2023; 95:16335-16342. [PMID: 37878838 DOI: 10.1021/acs.analchem.3c03573] [Citation(s) in RCA: 53] [Impact Index Per Article: 26.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
Cation exchange (CE) is a burgeoning method for controlled crystal synthesis; however, its applications in bioanalysis are still in their infancy. Herein, we explored the transformation of ZnIn2S4 in properties after the CE reaction with Cu2+ ions; furthermore, the discrepancy was employed to design a dual-readout detection system of photothermal and polarity-switchable photoelectrochemical (PEC) immunoassays to realize reliable detection of carcinoembryonic antigen (CEA). In the presence of CEA, the CuO nanoparticles (CuO NPs) employed as dual-signal response probes would bond to the microplates and be acidolyzed by HCl to release Cu2+, which could replace Zn2+ and In3+ via the CE reaction. After the CE reaction is completed, the photocurrent would switch from a weak anodic photocurrent to a cathode one by using a 635 nm laser as a signal amplifier, while the photothermal signal would be enhanced with 808 nm laser illumination. On the basis of the polarity-switchable PEC strategy, CEA could be accurately detected from 0.1 to 50 ng mL-1 with a limit of detection (LOD) of 48 pg mL-1 (S/N = 3). Moreover, the photothermal assay for CEA detection possesses a linear range from 0.5 to 100 ng mL-1 with a LOD of 0.21 ng mL-1. In addition, the designed sensing platform only relies on devices with portability that are permitted for point-of-care detection.
Collapse
Affiliation(s)
- Liling Lu
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Ruijin Zeng
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Qianyun Lin
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Xue Huang
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Dianping Tang
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| |
Collapse
|
3
|
Geng W, Xue L, Li Y, Ji J, Yuan X, Ding L, Yang R. A dual-model immobilization-free photoelectrochemical/visual colorimetric bioanalysis based on microemulsion self-assemblies mediated multifunctional signal amplification strategy. Anal Chim Acta 2023; 1277:341644. [PMID: 37604608 DOI: 10.1016/j.aca.2023.341644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 07/19/2023] [Indexed: 08/23/2023]
Abstract
Herein, a novel silver ion-loaded gold microemulsion assemblies (Au/Ag+ MAs) mediated multifunctional signal amplification strategy was proposed to construct a sensitive immobilization-free photoelectrochemical (PEC)/colorimetric biosensor for carcinoembryonic antigen (CEA) detection. Through the sandwiched reaction among CEA, the CEA aptamer (DNA1) loaded on the Au nanoparticles (NPs) functionalized iron oxide (Fe3O4) nanospheres and another CEA aptamer (DNA2) immobilized on Au/Ag+ MAs, a complex is formed and acquired by magnetic separation. Then, Au/Ag+ MAs of the complex are disassembled into Au NPs and Ag+ ions driven by an acetone response, and the obtained demulsification solution is transferred to the cadmium sulfide/cadmium telluride (CdS/CdTe) photoactive composites modified electrode. Based on the multiple inhibition functions (blocking effect of oleylamine; energy transfer effect of Au NPs; and electron snatching effect of Ag+), the photocurrent of the electrode decreases obviously, resulting in the ultrasensitive detection of CEA (a detection limit of 16 fg mL-1). Interestingly, the ion-exchange reactions between CdS/CdTe composites and Ag+ ions generate silver sulfide/silver telluride (Ag2S/Ag2Te) composites, and a color change of composites can be distinguished directly, leading to a quick visual detection of CEA. Compared with the traditional single-modal assay for CEA, such dual-modal PEC/colorimetric assay is a more accurate and reliable due to different mechanisms and independent signal conversion. This work will offer a new perspective for the applications of various self-assemblies in PEC bioanalysis.
Collapse
Affiliation(s)
- Wenchao Geng
- School of Chemical and Printing Dyeing Engineering, Henan University of Engineering, Zhengzhou, 451191, China
| | - Linsheng Xue
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Yuling Li
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Jiangying Ji
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Xinxin Yuan
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Lihua Ding
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Ruiying Yang
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China.
| |
Collapse
|
4
|
Bu Y, Wang K, Yang X, Nie G. Sensitive dual-mode sensing platform for Amyloid β detection: Combining dual Z-scheme heterojunction enhanced photoelectrochemistry analysis and dual-wavelength ratiometric electrochemiluminescence strategy. Biosens Bioelectron 2023; 237:115507. [PMID: 37437453 DOI: 10.1016/j.bios.2023.115507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 06/19/2023] [Accepted: 06/30/2023] [Indexed: 07/14/2023]
Abstract
As a tumor biomarker, the accumulation of amyloid β oligomers (Aβo) in the brain has been suggested as a key feature in the pathogenesis and progression of Alzheimer's disease (AD). In this work, we designed a novel photoelectrochemical (PEC) and electrochemiluminescence resonance energy transfer (ECL-RET) dual-mode biosensor to achieve ultra-sensitive detection of Aβo. Specifically, the electrode surface modified Carbon Dots (C Dots) and the electrodeposited polyaniline (PANI) film formed a Z-scheme heterojunction reversing the photocurrent signal, and then the Aβo specific recognition peptide was attached to the surface via amide bonding between the amino group of PANI and carbonyl group of peptide. After that, in the presence of CdTe labeled specific recognition aptamer for Aβ (CdTe-Apt), Aβo was captured to construct a sandwich-type biosensor and exhibited a significantly enhanced cathodic photocurrent response because the formed dual Z-scheme heterojunction promoted charge separation efficiency. Interestingly, the proposed biosensor also caused a ratiometric change in the ECL intensity at 555 nm and 640 nm. Therefore, the developed biosensor achieved dual-mode detection of Aβo, where the PEC detection range of Aβo was from 10 fM to 0.1 μM (with a detection limit of 4.27 fM) and the ECL method provided a linear detection range of 10 fM to 10 nM (with a detection limit of 6.41 fM). The stability and reliability of the experimental results indicate that this has been a promising biosensing pattern and could be extended to the analysis of other biomarkers.
Collapse
Affiliation(s)
- Yuwei Bu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| | - Kun Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| | - Xiaoyan Yang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China.
| | - Guangming Nie
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China.
| |
Collapse
|
5
|
Li Y, Wang S, Zhao Y, Li Y, Wang P, Xie H, Zhao P, Li Y, Liu Q, Wei Q. Design of a Double-Photoelectrode Sensing System with a Metal-Organic Framework-Based Antenna-like Strategy for Highly Sensitive Detection of PD-L1. Anal Chem 2023; 95:8720-8727. [PMID: 37224306 DOI: 10.1021/acs.analchem.3c01516] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Currently, the construction of heterojunctions as a method to enhance photoelectrochemical (PEC) activity has shown prospective applications in the analytical field. Restricted by carrier separation at the interface, developing a heterojunction sensing platform with high sensitivity remains challenging. Here, a double-photoelectrode PEC sensing platform was fabricated based on an antenna-like strategy by integrating MIL-68(In)-NH2, a p-type metal-organic framework (MOF) photocatalyst, as a photocathode with the type-II heterojunction of CdSe/MgIn2S4 as a photoanode synchronously. According to the ligand-to-metal charge transition (LMCT), the photo-generated carriers of MIL-68(In)-NH2 transferred from the organic ligand to the metal cluster, which provides an efficient antenna-like transfer path for the charge at the heterojunction interface. In addition, the sufficient Fermi energy difference between the double photoelectrode provides the continuous internal driving force required for rapid carrier separation at the anode detection interface, significantly improving the photoelectric conversion efficiency. Hence, compared with the traditional heterojunction single electrode, the photocurrent response of the double-photoelectrode PEC sensing platform developed using the antenna-like strategy is 2.5 times stronger. Based on this strategy, we constructed a PEC biosensor for the detection of programed death-ligand 1 (PD-L1). The elaborated PD-L1 biosensor exhibited sensitive and precise detection capability with a detection range of 1 × 10-5 to 1 × 103 ng/mL and a lower detection limit of 3.26 × 10-6 ng/mL and demonstrated the feasibility of serum sample detection, providing a novel and viable approach for the unmet clinical need of PD-L1 quantification. More importantly, the charge separation mechanism at the heterojunction interface proposed in this study provides new creative inspiration for designing sensors with high-sensitivity PEC performance.
Collapse
Affiliation(s)
- Yamei Li
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, P. R. China
| | - Shujun Wang
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, P. R. China
| | - Yan Zhao
- Zibo Central Hospital, Zibo 255036, P. R. China
| | - Yueyuan Li
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, P. R. China
| | - Ping Wang
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, P. R. China
| | | | | | - Yueyun Li
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, P. R. China
| | - Qing Liu
- School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, P. R. China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction and Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| |
Collapse
|
6
|
Qureshi A, Shaikh T, Niazi JH. Semiconductor quantum dots in photoelectrochemical sensors from fabrication to biosensing applications. Analyst 2023; 148:1633-1652. [PMID: 36880521 DOI: 10.1039/d2an01690g] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
Semiconductor quantum dots (QDs) are a promising class of nanomaterials for developing new photoelectrodes and photoelectrochemistry systems for energy storage, transfer, and biosensing applications. These materials have unique electronic and photophysical properties and can be used as optical nanoprobes in displays, biosensors, imaging, optoelectronics, energy storage and energy harvesting. Researchers have recently been exploring the use of QDs in photoelectrochemical (PEC) sensors, which involve exciting a QD-interfaced photoactive material with a flashlight source and generating a photoelectrical current as an output signal. The simple surface properties of QDs also make them suitable for addressing issues related to sensitivity, miniaturization, and cost-effectiveness. This technology has the potential to replace current laboratory practices and equipment, such as spectrophotometers, used for testing sample absorption and emission. Semiconductor QD-based PEC sensors offer simple, fast, and easily miniaturized sensors for analyzing a variety of analytes. This review summarizes the various strategies for interfacing QD nanoarchitectures for PEC sensing, as well as their signal amplification. PEC sensing devices, particularly those used for the detection of disease biomarkers, biomolecules (glucose, dopamine), drugs, and various pathogens, have the potential to revolutionize the biomedical field. This review discusses the advantages of semiconductor QD-based PEC biosensors and their fabrication methods, with a focus on disease diagnostics and the detection of various biomolecules. Finally, the review provides prospects and considerations for QD-based photoelectrochemical sensor systems in terms of their sensitivity, speed, and portability for biomedical applications.
Collapse
Affiliation(s)
- Anjum Qureshi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Orta Mah, Tuzla 34956, Istanbul, Turkey.
| | - Tayyaba Shaikh
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Orta Mah, Tuzla 34956, Istanbul, Turkey.
| | - Javed H Niazi
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Orta Mah, Tuzla 34956, Istanbul, Turkey.
| |
Collapse
|
7
|
Wu T, Du Y, Gao Z, Xu K, Dai L, Liu L, Li F, Wei Q, Ju H. Dual Direct Z-Scheme Heterojunction with Stable Electron Supply to a Au/PANI Photocathode for Ultrasensitive Photoelectrochemical and Electrochromic Visualization Detection of Ofloxacin in a Microfluidic Sensing Platform. Anal Chem 2023; 95:1627-1634. [PMID: 36574294 DOI: 10.1021/acs.analchem.2c04740] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A novel dual-mode microfluidic analytical device integrating self-powered photoelectrochemical (PEC) sensing with electrochromic visualization analysis was developed for ultrasensitive ofloxacin (OFL) detection. First, an advanced dual direct Z-scheme BiVO4@Ni-ZnIn2S4/Bi2S3 (BVZIS) heterojunction was designed as a photoanode matrix to steadily provide electrons. The dual Z-scheme structure formed in photoactive BVZIS composites greatly accelerated the migration of electrons. In addition, the doping of Ni in ZnIn2S4 markedly enhanced the optical absorption and promoted the separation of the photocarrier. Second, electrochromic material polyaniline-modified Au (Au/PANI) was first electrodeposited on the photocathode for immobilizing aptamers and realizing visualized readout. On the one hand, Au/PANI with excellent conductivity could receive electrons from the photoanode without external energy supply. On the other hand, PANI would be rapidly reduced by the received electrons and change its color from blue to green obviously. With the increase in OFL, the increased steric hindrance resulted in the significant decline in the PEC signal and RGBgreen value. Third, wide linear ranges of PEC (0.05 pg/mL to 150 ng/mL) and electrochromic technique (0.1 pg/mL to 100 ng/mL) as well as low detection limits of PEC (18 fg/mL) and electrochromic (30 fg/mL) sensors could achieve the ultrasensitive detection of OFL in milk and river water.
Collapse
Affiliation(s)
- Tingting Wu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Yu Du
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Zhongfeng Gao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Kun Xu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Li Dai
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Lei Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Faying Li
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China.,Department of Chemistry, Sungkyunkwan University, Suwon16419, Republic of Korea
| | - Huangxian Ju
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shangdong250022, P. R. China.,State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing210023, P. R. China
| |
Collapse
|
8
|
Photoelectrochemical aptasensor based on cascade dual Z-scheme CdTe-polyaniline@MoS2 heterostructure for the sensitive carbendazim detection. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
9
|
Huang X, Lin Q, Lu L, Li M, Tang D. In 2O 3/CdIn 2S 4 heterojunction-based photoelectrochemical immunoassay of carcinoembryonic antigen with enzymatic biocatalytic precipitation for signal amplification. Anal Chim Acta 2022; 1228:340358. [PMID: 36127005 DOI: 10.1016/j.aca.2022.340358] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Revised: 09/01/2022] [Accepted: 09/02/2022] [Indexed: 11/19/2022]
Abstract
This work reported a split-type photoelectrochemical (PEC) immunoassay for the detection of carcinoembryonic antigen (CEA) based on target-induced biocatalytic precipitation (BCP) by using In2O3/CdIn2S4 heterojunctions as the photosensitizers. The synthesized In2O3/CdIn2S4 heterojunctions improved the efficiency of charge separation and shortened the electron convey path to enhance the photocurrent, thus exhibiting high conductivity and low complexation rates of photogenerated electrons and holes. In the presence of CEA, horseradish peroxidase (HRP) catalyzed 4-chloro-1-naphthol (4-CN) to produce benzo-4-chloro-hexadienone (4-CD) through H2O2. Then, 4-CD was deposited onto the surface of In2O3/CdIn2S4 to reduce the photocurrent and realized the signal amplification. The PEC immunoassay revealed an excellent photocurrent toward target CEA within a wide range of 0.01-50 ng mL-1 at a low limit of detection of 2.8 pg mL-1 under the optimum conditions. Multiple switching light excitation tests demonstrated the good reliability and stability of the fabricated PEC biosensor. The accuracy was acceptable in comparison with human CEA enzyme-linked immunosorbent assay (ELISA) kit.
Collapse
Affiliation(s)
- Xue Huang
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Qianyun Lin
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Liling Lu
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Meijin Li
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China.
| | - Dianping Tang
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China.
| |
Collapse
|