1
|
Panda M, Kalita E, Singh S, Rao A, Prajapati VK. Application of functional proteomics in understanding RNA virus-mediated infection. ADVANCES IN PROTEIN CHEMISTRY AND STRUCTURAL BIOLOGY 2023; 138:301-325. [PMID: 38220429 DOI: 10.1016/bs.apcsb.2023.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
Abstract
Together with the expansion of genome sequencing research, the number of protein sequences whose function is yet unknown is increasing dramatically. The primary goals of functional proteomics, a developing area of study in the realm of proteomic science, are the elucidation of the biological function of unidentified proteins and the molecular description of cellular systems at the molecular level. RNA viruses have emerged as the cause of several human infectious diseases with large morbidity and fatality rates. The introduction of high-throughput sequencing tools and genetic-based screening approaches over the last few decades has enabled researchers to find previously unknown and perplexing elements of RNA virus replication and pathogenesis on a scale never feasible before. Viruses, on the other hand, frequently disrupt cellular proteostasis, macromolecular complex architecture or stoichiometry, and post-translational changes to take over essential host activities. Because of these consequences, structural and global protein and proteoform monitoring is highly necessiated. Mass spectrometry (MS) has the potential to elucidate key details of virus-host interactions and speed up the identification of antiviral targets, giving precise data on the stoichiometry of cellular and viral protein complexes as well as mechanistic insights, has lately emerged as a key part of the RNA virus biology toolbox as a functional proteomics approach. Affinity-based techniques are primarily employed to identify interacting proteins in stable complexes in living organisms. A protein's biological role is strongly suggested by its relationship with other members of a certain protein complex that is involved in a particular process. With a particular emphasis on the most recent advancements in defining host responses and their translational implications to uncover novel tractable antiviral targets, this chapter provides insight on several functional proteomics techniques in RNA virus biology.
Collapse
Affiliation(s)
- Mamta Panda
- Department of Biochemistry, School of Life Sciences, Central University of Rajasthan, Ajmer, Rajasthan, India; Department of Neurology. Experimental Research in Stroke and Inflammation (ERSI),University Medical Center Hamburg-Eppendorf Martinistraße Hamburg, Germany
| | - Elora Kalita
- Department of Biochemistry, School of Life Sciences, Central University of Rajasthan, Ajmer, Rajasthan, India
| | - Satyendra Singh
- Department of Biochemistry, School of Life Sciences, Central University of Rajasthan, Ajmer, Rajasthan, India
| | - Abhishek Rao
- Department of Biochemistry, School of Life Sciences, Central University of Rajasthan, Ajmer, Rajasthan, India
| | - Vijay Kumar Prajapati
- Department of Biochemistry, University of Delhi South Campus, Dhaula Kuan, New Delhi, India.
| |
Collapse
|
2
|
Zoratto S, Heuser T, Friedbacher G, Pletzenauer R, Graninger M, Marchetti-Deschmann M, Weiss VU. Adeno-Associated Virus-like Particles' Response to pH Changes as Revealed by nES-DMA. Viruses 2023; 15:1361. [PMID: 37376661 DOI: 10.3390/v15061361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/29/2023] [Accepted: 06/08/2023] [Indexed: 06/29/2023] Open
Abstract
Gas-phase electrophoresis on a nano-Electrospray Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) separates single-charged, native analytes according to the surface-dry particle size. A volatile electrolyte, often ammonium acetate, is a prerequisite for electrospraying. Over the years, nES GEMMA has demonstrated its unique capability to investigate (bio-)nanoparticle containing samples in respect to composition, analyte size, size distribution, and particle numbers. Virus-like particles (VLPs), being non-infectious vectors, are often employed for gene therapy applications. Focusing on adeno-associated virus 8 (AAV8) based VLPs, we investigated the response of these bionanoparticles to pH changes via nES GEMMA as ammonium acetate is known to exhibit these changes upon electrospraying. Indeed, slight yet significant differences in VLP diameters in relation to pH changes are found between empty and DNA-cargo-filled assemblies. Additionally, filled VLPs exhibit aggregation in dependence on the applied electrolyte's pH, as corroborated by atomic force microscopy. In contrast, cryogenic transmission electron microscopy did not relate to changes in the overall particle size but in the substantial particle's shape based on cargo conditions. Overall, we conclude that for VLP characterization, the pH of the applied electrolyte solution has to be closely monitored, as variations in pH might account for drastic changes in particles and VLP behavior. Likewise, extrapolation of VLP behavior from empty to filled particles has to be carried out with caution.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Thomas Heuser
- Electron Microscopy Facility, Vienna BioCenter Core Facilities GmbH, A-1030 Vienna, Austria
| | - Gernot Friedbacher
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Robert Pletzenauer
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria
| | - Michael Graninger
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria
| | | | - Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| |
Collapse
|
3
|
Bischoff AJ, Harper CC, Williams ER, Francis MB. Characterizing Heterogeneous Mixtures of Assembled States of the Tobacco Mosaic Virus Using Charge Detection Mass Spectrometry. J Am Chem Soc 2022; 144:23368-23378. [PMID: 36525679 PMCID: PMC10395586 DOI: 10.1021/jacs.2c09160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The tobacco mosaic viral capsid protein (TMV) is a frequent target for derivatization for myriad applications, including drug delivery, biosensing, and light harvesting. However, solutions of the stacked disk assembly state of TMV are difficult to characterize quantitatively due to their large size and multiple assembled states. Charge detection mass spectrometry (CDMS) addresses the need to characterize heterogeneous populations of large protein complexes in solution quickly and accurately. Using CDMS, previously unobserved assembly states of TMV, including 16-monomer disks and odd-numbered disk stacks, have been characterized. We additionally employed a peptide-protein conjugation reaction in conjunction with CDMS to demonstrate that modified TMV proteins do not redistribute between disks. Finally, this technique was used to discriminate between protein complexes of near-identical mass but different configurations. We have gained a greater understanding of the behavior of TMV, a protein used across a broad variety of fields and applications, in the solution state.
Collapse
Affiliation(s)
- Amanda J. Bischoff
- College of Chemistry, University of California, Berkeley, California, 94720, United States
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratories, Berkeley, California, 94720, United States
| | - Conner C. Harper
- College of Chemistry, University of California, Berkeley, California, 94720, United States
| | - Evan R. Williams
- College of Chemistry, University of California, Berkeley, California, 94720, United States
| | - Matthew B. Francis
- College of Chemistry, University of California, Berkeley, California, 94720, United States
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratories, Berkeley, California, 94720, United States
| |
Collapse
|
4
|
Miller ZM, Harper CC, Lee H, Bischoff AJ, Francis MB, Schaffer DV, Williams ER. Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:2129-2137. [PMID: 36173188 PMCID: PMC10389282 DOI: 10.1021/jasms.2c00213] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.
Collapse
Affiliation(s)
- Zachary M. Miller
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Conner C. Harper
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Hyuncheol Lee
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460, United States
| | - Amanda J. Bischoff
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratories, Berkeley, California 94720, United States
| | - Matthew B. Francis
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratories, Berkeley, California 94720, United States
| | - David V. Schaffer
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Evan R. Williams
- College of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| |
Collapse
|
5
|
Harper CC, Miller ZM, Lee H, Bischoff AJ, Francis MB, Schaffer DV, Williams ER. Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry. Anal Chem 2022; 94:11703-11712. [PMID: 35961005 PMCID: PMC10389281 DOI: 10.1021/acs.analchem.2c02572] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett's advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. This phenomenon is illustrated with both tobacco mosaic virus (0.6-2.7 MDa) and AAV9 (3.7-4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.
Collapse
Affiliation(s)
- Conner C. Harper
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
| | - Zachary M. Miller
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
| | - Hyuncheol Lee
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
| | - Amanda J. Bischoff
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratories, Berkeley, California 94720
| | - Matthew B. Francis
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratories, Berkeley, California 94720
| | - David V. Schaffer
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
| | - Evan R. Williams
- College of Chemistry, University of California, Berkeley, California, 94720-1460
- California Institute for Quantitative Biosciences, University of California, Berkeley, California 94720-1460
| |
Collapse
|
6
|
Erdogan RT, Alkhaled M, Kaynak BE, Alhmoud H, Pisheh HS, Kelleci M, Karakurt I, Yanik C, Şen ZB, Sari B, Yagci AM, Özkul A, Hanay MS. Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems. ACS NANO 2022; 16:3821-3833. [PMID: 35785967 DOI: 10.1021/acsnano.1c08423] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Cenk Yanik
- Sabancı University, SUNUM Nanotechnology Research and Application Center, 34956 Istanbul, Turkey
| | | | - Burak Sari
- Faculty of Engineering and Natural Sciences, Sabancı University, 34956 Istanbul, Turkey
| | | | - Aykut Özkul
- Faculty of Veterinary Medicine, Department of Virology, Ankara University, 06110 Ankara, Turkey
- Biotechnology Institute, Ankara University, 06135 Ankara, Turkey
| | | |
Collapse
|
7
|
nES-DMA with Charge-reduction based on Soft X-ray Radiation: Analysis of a Recombinant Monoclonal Antibody. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1182:122925. [PMID: 34543886 DOI: 10.1016/j.jchromb.2021.122925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 08/05/2021] [Accepted: 09/01/2021] [Indexed: 11/22/2022]
Abstract
Due to the fast growing importance of monoclonal antibodies in biomedical research, bioanalytics and human therapy, sensitive, fast and reliable methods are needed to monitor their production, target their characteristics, and for their final quality control. Application of a nano electrospray (nES) with soft X-ray radiation (SXR) based charge reduction and differential mobility analysis (DMA, aka nano electrospray gas-phase electrophoretic mobility molecular analysis, nES GEMMA) allows the size-separation and detection of macromolecules and (bio-)nanoparticles from a few nm up to several hundreds of nm in diameter in a native-like environment. The current study focuses on the analysis of a 148 kDa recombinant monoclonal antibody (rmAb) with the above mentioned instrumental setup and applying an universal detector, i.e. a water-based condensation particle detector (CPC). Next to the intact rmAb, its aggregates and fragment products after digestion with IdeS protease were analyzed. Additionally, influence of temperature treatment and pH variation on the stability of the rmAb was monitored. In this context, changes in electrophoretic mobility diameter (EMD) values, peak shape, and signal intensity based on particle numbers were of interest. Molecular weights calculated by application of a correlation derived from respective standard protein compounds were compared to mass spectrometric values and were found to be in good accordance. To conclude, we demonstrate that nES-DMA is a valuable tool in the characterization and quality control of rmABs.
Collapse
|
8
|
Fernandez de la Mora J, Angel DM, Peccia J. How Narrow Is the Gas Phase Mobility Distribution of Enveloped Viruses? The Case of the Φ6 Bacteriophage. Anal Chem 2021; 93:12938-12943. [PMID: 34520175 DOI: 10.1021/acs.analchem.1c02402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
We use the Φ6 bacteriophage previously exploited as a BSL-1 surrogate of severe acute respiratory syndrome coronavirus (SARS-CoV) and Middle East respiratory syndrome (MERS) coronavirus to obtain the first high-resolution gas phase mobility spectra of an enveloped virus. The relative full width at half-maximum found for the viral mobility distribution (FWHMZ < 3.7%) is substantially narrower than that reported by prior mobility or microscopy studies with other enveloped viruses. It is nevertheless not as narrow as that recently found for several non-enveloped viruses (FWHMZ ≈ 2%), presumably due to particle to particle variability of enveloped viruses. This 3.7% is an upper bound to the actual width. Nevertheless, the well-defined mobility peaks obtained indicate that gas phase mobility analysis is a more discriminating methodology than that previously demonstrated for physically based non-genetic viral diagnostic of enveloped viruses. These results are obtained by analysis of the original cell culture medium containing the virus, purified only by passage through a 0.22 μm filter and by dialysis into a 10 mM aqueous ammonium acetate buffer. We confirmed that this buffer exchange preserves infectivity. Therefore, the 63.7 nm mobility diameter found, although smaller than the 75 nm previously inferred by microscopy, corresponds to the full particle including the envelope.
Collapse
Affiliation(s)
- Juan Fernandez de la Mora
- Department of Mechanical Engineering and Materials Science, Yale University, Mason Laboratory, 9 Hillhouse Avenue, New Haven, Connecticut 06520-8286, United States
| | - Darryl Marissa Angel
- Department of Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06511, United States
| | - Jordan Peccia
- Department of Chemical and Environmental Engineering, Yale University, New Haven, Connecticut 06511, United States
| |
Collapse
|
9
|
Zoratto S, Weiss VU, van der Horst J, Commandeur J, Buengener C, Foettinger‐Vacha A, Pletzenauer R, Graninger M, Allmaier G. Molecular weight determination of adeno-associate virus serotype 8 virus-like particle either carrying or lacking genome via native nES gas-phase electrophoretic molecular mobility analysis and nESI QRTOF mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4786. [PMID: 34608711 PMCID: PMC9285973 DOI: 10.1002/jms.4786] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 09/13/2021] [Indexed: 06/13/2023]
Abstract
Virus-like particles (VLPs) are proteinaceous shells derived from viruses lacking any viral genomic material. Adeno-associated virus (AAV) is a non-enveloped icosahedral virus used as VLP delivery system in gene therapy (GT). Its success as vehicle for GT is due to its selective tropism, high level of transduction, and low immunogenicity. In this study, two preparations of AAV serotype 8 (AAV8) VLPs either carrying or lacking completely genomic cargo (i.e., non-viral ssDNA) have been investigated by means of a native nano-electrospray gas-phase electrophoretic mobility molecular analyzer (GEMMA) (native nES GEMMA) and native nano-electrospray ionization quadrupole reflectron time-of-flight mass spectrometry (MS) (native nESI QRTOF MS). nES GEMMA is based on electrophoretic mobility principles: single-charge nanoparticles (NPs), that is, AAV8 particle, are separated in a laminar sheath flow of dry, particle-free air and a tunable orthogonal electric field. Thus, the electrophoretic mobility diameter (EMD) of a bio-NP (i.e., diameter of globular nano-objects) is obtained at atmospheric pressure, which can be converted into its MW based on a correlation. First is the native nESI QRTOF. MS's goal is to keep the native biological conformation of an analyte during the passage into the vacuum. Subsequently, highly accurate MW values are obtained from multiple-charged species after deconvolution. However, once applied to the analysis of megadalton species, native MS is challenging and requires customized instrumental modifications not readily available on standard devices. Hence, the analysis of AAV8 VLPs via native MS in our hands did not produce a defined charge state assignment, that is, charge deconvolution for exact MW determination was not possible. Nonetheless, the method we present is capable to estimate the MW of VLPs by combining the results from native nES GEMMA and native ESI QRTOF MS. In detail, our findings show a MW of 3.7 and 5.0 MDa for AAV8 VLPs either lacking or carrying an engineered genome, respectively.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Victor U. Weiss
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | | | | | - Carsten Buengener
- Pharmaceutical SciencesBaxalta Innovations (part of Takeda)ViennaAustria
| | | | - Robert Pletzenauer
- Pharmaceutical SciencesBaxalta Innovations (part of Takeda)ViennaAustria
| | - Michael Graninger
- Pharmaceutical SciencesBaxalta Innovations (part of Takeda)ViennaAustria
| | - Guenter Allmaier
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| |
Collapse
|
10
|
Britt HM, Cragnolini T, Thalassinos K. Integration of Mass Spectrometry Data for Structural Biology. Chem Rev 2021; 122:7952-7986. [PMID: 34506113 DOI: 10.1021/acs.chemrev.1c00356] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Mass spectrometry (MS) is increasingly being used to probe the structure and dynamics of proteins and the complexes they form with other macromolecules. There are now several specialized MS methods, each with unique sample preparation, data acquisition, and data processing protocols. Collectively, these methods are referred to as structural MS and include cross-linking, hydrogen-deuterium exchange, hydroxyl radical footprinting, native, ion mobility, and top-down MS. Each of these provides a unique type of structural information, ranging from composition and stoichiometry through to residue level proximity and solvent accessibility. Structural MS has proved particularly beneficial in studying protein classes for which analysis by classic structural biology techniques proves challenging such as glycosylated or intrinsically disordered proteins. To capture the structural details for a particular system, especially larger multiprotein complexes, more than one structural MS method with other structural and biophysical techniques is often required. Key to integrating these diverse data are computational strategies and software solutions to facilitate this process. We provide a background to the structural MS methods and briefly summarize other structural methods and how these are combined with MS. We then describe current state of the art approaches for the integration of structural MS data for structural biology. We quantify how often these methods are used together and provide examples where such combinations have been fruitful. To illustrate the power of integrative approaches, we discuss progress in solving the structures of the proteasome and the nuclear pore complex. We also discuss how information from structural MS, particularly pertaining to protein dynamics, is not currently utilized in integrative workflows and how such information can provide a more accurate picture of the systems studied. We conclude by discussing new developments in the MS and computational fields that will further enable in-cell structural studies.
Collapse
Affiliation(s)
- Hannah M Britt
- Institute of Structural and Molecular Biology, Division of Biosciences, University College London, London WC1E 6BT, United Kingdom
| | - Tristan Cragnolini
- Institute of Structural and Molecular Biology, Division of Biosciences, University College London, London WC1E 6BT, United Kingdom.,Institute of Structural and Molecular Biology, Birkbeck College, University of London, London WC1E 7HX, United Kingdom
| | - Konstantinos Thalassinos
- Institute of Structural and Molecular Biology, Division of Biosciences, University College London, London WC1E 6BT, United Kingdom.,Institute of Structural and Molecular Biology, Birkbeck College, University of London, London WC1E 7HX, United Kingdom
| |
Collapse
|
11
|
Abstract
Native mass spectrometry (MS) is aimed at preserving and determining the native structure, composition, and stoichiometry of biomolecules and their complexes from solution after they are transferred into the gas phase. Major improvements in native MS instrumentation and experimental methods over the past few decades have led to a concomitant increase in the complexity and heterogeneity of samples that can be analyzed, including protein-ligand complexes, protein complexes with multiple coexisting stoichiometries, and membrane protein-lipid assemblies. Heterogeneous features of these biomolecular samples can be important for understanding structure and function. However, sample heterogeneity can make assignment of ion mass, charge, composition, and structure very challenging due to the overlap of tens or even hundreds of peaks in the mass spectrum. In this review, we cover data analysis, experimental, and instrumental advances and strategies aimed at solving this problem, with an in-depth discussion of theoretical and practical aspects of the use of available deconvolution algorithms and tools. We also reflect upon current challenges and provide a view of the future of this exciting field.
Collapse
Affiliation(s)
- Amber D Rolland
- Department of Chemistry and Biochemistry, University of Oregon, Eugene, Oregon 97403-1253, United States
| | - James S Prell
- Department of Chemistry and Biochemistry, University of Oregon, Eugene, Oregon 97403-1253, United States.,Materials Science Institute, University of Oregon, Eugene, Oregon 97403-1252, United States
| |
Collapse
|
12
|
Zoratto S, Weiss VU, Friedbacher G, Buengener C, Pletzenauer R, Foettinger-Vacha A, Graninger M, Allmaier G. Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy. ACS OMEGA 2021; 6:16428-16437. [PMID: 34235314 PMCID: PMC8246466 DOI: 10.1021/acsomega.1c01443] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/27/2021] [Indexed: 05/30/2023]
Abstract
Adeno-associated virus (AAV)-based virus-like particles (VLPs) are thriving vectors of choice in the biopharmaceutical field of gene therapy. Here, a method to investigate purified AAV serotype 8 (AAV8) batches via a nanoelectrospray gas-phase mobility molecular analyzer (nES GEMMA), also known as an nES differential mobility analyzer, is presented. Indeed, due to AAV's double-digit nanometer scale, nES GEMMA is an excellently suited technique to determine the surface-dry particle size termed electrophoretic mobility diameter of such VLPs in their native state at atmospheric pressure and with particle-number-based detection. Moreover, asymmetric flow field-flow fractionation (AF4, also known as AFFFF) and atomic force microscopy (AFM) techniques were employed as orthogonal techniques for VLP characterization. In addition, AF4 was implemented to size-separate as well as to enrich and collect fractions of AAV8 VLPs after inducing analyte aggregation in the liquid phase. Bionanoparticle aggregation was achieved by a combination of heat and shear stress. These fractions were later analyzed with nES GEMMA (in the gas phase) and AFM (on a solid surface). Both techniques confirm the presence of dimers, trimers, and putative VLP oligomers. Last, AFM reveals even larger AAV8 VLP aggregates, which were not detectable by nES GEMMA because their heterogeneity combined with low abundance was below the limit of detection of the instrument. Hence, the combination of the employed orthogonal sizing methods with the separation technique AF4 allow a comprehensive characterization of AAV8 VLPs applied as vectors.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Victor U. Weiss
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Gernot Friedbacher
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Carsten Buengener
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Robert Pletzenauer
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Alexandra Foettinger-Vacha
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Michael Graninger
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Guenter Allmaier
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| |
Collapse
|
13
|
Weiss VU, Denderz N, Allmaier G, Marchetti‐Deschmann M. Online hyphenation of size-exclusion chromatography and gas-phase electrophoresis facilitates the characterization of protein aggregates. Electrophoresis 2021; 42:1202-1208. [PMID: 33651392 PMCID: PMC8252587 DOI: 10.1002/elps.202100018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 02/06/2021] [Accepted: 02/07/2021] [Indexed: 11/07/2022]
Abstract
Gas-phase electrophoresis yields size distributions of polydisperse, aerosolized analytes based on electrophoretic principles. Nanometer-sized, surface-dry, single-charged particles are separated in a high laminar sheath flow of particle-free air and an orthogonal tunable electric field. Additionally, nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) data are particle-number based. Therefore, small particles can be detected next to larger ones without a bias, for example, native proteins next to their aggregates. Analyte transition from the liquid to the gas phase is a method inherent prerequisite. In this context, nonvolatile sample buffers influence results. In the worst case, the (bio-)nanoparticle signal is lost due to an increased baseline and unspecific clustering of nonvolatile components. We present a novel online hyphenation of liquid chromatography and gas-phase electrophoresis, coupling a size-exclusion chromatography (SEC) column to an advanced nES GEMMA. Via this novel approach, it is possible to (i) separate analyte multimers already present in liquid phase from aggregates formed during the nES process, (ii) differentiate liquid phase and spray-induced multimers, and (iii) to remove nonvolatile buffer components online before SEC-nES GEMMA analysis. Due to these findings, SEC-nES GEMMA has the high potential to help to understand aggregation processes in biological buffers adding the benefit of actual size determination for noncovalent assemblies formed in solution. As detection and characterization of protein aggregation in large-scale pharmaceutical production or sizing of noncovalently bound proteins are findings directly related to technologically and biologically relevant situations, we proposed the presented method to be a valuable addition to LC-MS approaches.
Collapse
Affiliation(s)
- Victor U. Weiss
- Institute for Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Natalia Denderz
- Institute for Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Günter Allmaier
- Institute for Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | | |
Collapse
|
14
|
Simanjuntak Y, Schamoni-Kast K, Grün A, Uetrecht C, Scaturro P. Top-Down and Bottom-Up Proteomics Methods to Study RNA Virus Biology. Viruses 2021; 13:668. [PMID: 33924391 PMCID: PMC8070632 DOI: 10.3390/v13040668] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 04/01/2021] [Accepted: 04/10/2021] [Indexed: 02/06/2023] Open
Abstract
RNA viruses cause a wide range of human diseases that are associated with high mortality and morbidity. In the past decades, the rise of genetic-based screening methods and high-throughput sequencing approaches allowed the uncovering of unique and elusive aspects of RNA virus replication and pathogenesis at an unprecedented scale. However, viruses often hijack critical host functions or trigger pathological dysfunctions, perturbing cellular proteostasis, macromolecular complex organization or stoichiometry, and post-translational modifications. Such effects require the monitoring of proteins and proteoforms both on a global scale and at the structural level. Mass spectrometry (MS) has recently emerged as an important component of the RNA virus biology toolbox, with its potential to shed light on critical aspects of virus-host perturbations and streamline the identification of antiviral targets. Moreover, multiple novel MS tools are available to study the structure of large protein complexes, providing detailed information on the exact stoichiometry of cellular and viral protein complexes and critical mechanistic insights into their functions. Here, we review top-down and bottom-up mass spectrometry-based approaches in RNA virus biology with a special focus on the most recent developments in characterizing host responses, and their translational implications to identify novel tractable antiviral targets.
Collapse
Affiliation(s)
- Yogy Simanjuntak
- Leibniz Institute for Experimental Virology (HPI), 20251 Hamburg, Germany; (Y.S.); (K.S.-K.); (A.G.)
| | - Kira Schamoni-Kast
- Leibniz Institute for Experimental Virology (HPI), 20251 Hamburg, Germany; (Y.S.); (K.S.-K.); (A.G.)
| | - Alice Grün
- Leibniz Institute for Experimental Virology (HPI), 20251 Hamburg, Germany; (Y.S.); (K.S.-K.); (A.G.)
- Centre for Structural Systems Biology, 22607 Hamburg, Germany
| | - Charlotte Uetrecht
- Leibniz Institute for Experimental Virology (HPI), 20251 Hamburg, Germany; (Y.S.); (K.S.-K.); (A.G.)
- Centre for Structural Systems Biology, 22607 Hamburg, Germany
- European XFEL GmbH, 22869 Schenefeld, Germany
| | - Pietro Scaturro
- Leibniz Institute for Experimental Virology (HPI), 20251 Hamburg, Germany; (Y.S.); (K.S.-K.); (A.G.)
| |
Collapse
|
15
|
Harper CC, Brauer DD, Francis MB, Williams ER. Direct observation of ion emission from charged aqueous nanodrops: effects on gaseous macromolecular charging. Chem Sci 2021; 12:5185-5195. [PMID: 34168773 PMCID: PMC8179642 DOI: 10.1039/d0sc05707j] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Mechanistic information about how gaseous ions are formed from charged droplets has been difficult to establish because direct observation of nanodrops in a size range relevant to gaseous macromolecular ion formation by optical or traditional mass spectrometry methods is challenging owing to their small size and heterogeneity. Here, the mass and charge of individual aqueous nanodrops between 1-10 MDa (15-32 nm diameter) with ∼50-300 charges are dynamically monitored for 1 s using charge detection mass spectrometry. Discrete losses of minimally solvated singly charged ions occur, marking the first direct observation of ion emission from aqueous nanodrops in late stages of droplet evaporation relevant to macromolecular ion formation in native mass spectrometry. Nanodrop charge depends on the identity of constituent ions, with pure water nanodrops charged slightly above the Rayleigh limit and aqueous solutions containing alkali metal ions charged progressively below the Rayleigh limit with increasing cation size. MS2 capsid ions (∼3.5 MDa; ∼27 nm diameter) are more highly charged from aqueous ammonium acetate than from its biochemically preferred, 100 mM NaCl/10 mM Na phosphate solution, consistent with ion emission reducing the nanodrop and resulting capsid charge. The extent of charging indicates that the capsid partially collapses inside the nanodrops prior to the charging and formation of the dehydrated gaseous ions. These results demonstrate that ion emission can affect macromolecular charging and that conformational changes to macromolecular structure can occur in nanodrops prior to the formation of naked gaseous ions.
Collapse
Affiliation(s)
- Conner C Harper
- Department of Chemistry, University of California Berkeley California 94720-1460 USA
| | - Daniel D Brauer
- Department of Chemistry, University of California Berkeley California 94720-1460 USA
| | - Matthew B Francis
- Department of Chemistry, University of California Berkeley California 94720-1460 USA
| | - Evan R Williams
- Department of Chemistry, University of California Berkeley California 94720-1460 USA
| |
Collapse
|
16
|
Affiliation(s)
- Tobias
P. Wörner
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Tatiana M. Shamorkina
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Joost Snijder
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Albert J. R. Heck
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute of Pharmaceutical Sciences, Utrecht University, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| |
Collapse
|
17
|
N-terminal VP1 Truncations Favor T = 1 Norovirus-Like Particles. Vaccines (Basel) 2020; 9:vaccines9010008. [PMID: 33374273 PMCID: PMC7824077 DOI: 10.3390/vaccines9010008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/18/2020] [Accepted: 12/21/2020] [Indexed: 12/20/2022] Open
Abstract
Noroviruses cause immense sporadic gastroenteritis outbreaks worldwide. Emerging genotypes, which are divided based on the sequence of the major capsid protein VP1, further enhance this public threat. Self-assembling properties of the human norovirus major capsid protein VP1 are crucial for using virus-like particles (VLPs) for vaccine development. However, there is no vaccine available yet. Here, VLPs from different variants produced in insect cells were characterized in detail using a set of biophysical and structural tools. We used native mass spectrometry, gas-phase electrophoretic mobility molecular analysis, and proteomics to get clear insights into particle size, structure, and composition, as well as stability. Generally, noroviruses have been known to form mainly T = 3 particles. Importantly, we identified a major truncation in the capsid proteins as a likely cause for the formation of T = 1 particles. For vaccine development, particle production needs to be a reproducible, reliable process. Understanding the underlying processes in capsid size variation will help to produce particles of a defined capsid size presenting antigens consistent with intact virions. Next to vaccine production itself, this would be immensely beneficial for bio-/nano-technological approaches using viral particles as carriers or triggers for immunological reactions.
Collapse
|
18
|
Weiss VU, Frank J, Piplits K, Szymanski WW, Allmaier G. Bipolar Corona Discharge-Based Charge Equilibration for Nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analysis of Bio- and Polymer Nanoparticles. Anal Chem 2020; 92:8665-8669. [PMID: 32519840 PMCID: PMC7467421 DOI: 10.1021/acs.analchem.0c01904] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
![]()
Separation
of polydisperse, single-charged analytes in the nanometer
size range in a high laminar sheath flow of particle-free ambient
air and a tunable electric field based on the respective particle
electrophoretic mobility diameter (EMD) can be achieved via gas-phase
electrophoresis. In order to transfer analytes from a volatile electrolyte
solution to the gas-phase as a single-charged species, a nano electrospray
(nES) process followed by drying of nanodroplets and charge conditioning
reaching Boltzmann charge equilibrium is a necessary prerequisite.
In the case of a so-called nES gas-phase electrophoretic mobility
molecular analyzer (nES GEMMA, also known as nES differential mobility
analyzer, nES DMA), charge equilibration is based on bionanoparticle
interaction with a bipolar atmosphere induced, e.g., by a radioactive
α-particle emitter like 210Po. It was the aim of
our investigation to examine whether such a radioactive source can
be easily replaced in the same nES housing by a nonradioactive one,
i.e., by an AC corona discharge unit. The latter would be significantly
easier to handle when compared to radioactive material in laboratory
day-to-day business, waste disposal, as well as regulatory confinements.
Indeed, we were able to combine a standard nES unit of our nES GEMMA
instrument with a commercially available AC corona discharge device
in a novel setup via an adapter. Our results show that this replacement
yields very good results for a number of chemically different nanoparticles,
an exemplary protein, a noncovalent protein complex, a virus-like
particle, a polymer, and a liposome sample, when compared to a 210Po based bipolar charge equilibration device.
Collapse
Affiliation(s)
- Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Johannes Frank
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Kurt Piplits
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | | | - Günter Allmaier
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| |
Collapse
|
19
|
Nano electrospray differential mobility analysis based size-selection of liposomes and very-low density lipoprotein particles for offline hyphenation to MALDI mass spectrometry. J Pharm Biomed Anal 2020; 179:112998. [PMID: 31780280 DOI: 10.1016/j.jpba.2019.112998] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 11/14/2019] [Accepted: 11/17/2019] [Indexed: 11/21/2022]
Abstract
Gas-phase electrophoresis of single-charged analytes (nanoparticles) enables their separation according to the surface-dry particle size (Electrophoretic Mobility Diameter, EMD), which corresponds to the diameter of spherical shaped particles. Employing a nano Electrospray Differential Mobility Analyzer (nES DMA), also known as nES Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA), allows sizing/size-separation and determination of particle-number concentrations. Separations are based on a constant high laminar sheath flow and a tunable, orthogonal electric field enabling scanning of EMDs in the nanometer size range. Additionally, keeping the voltage constant, only nanoparticles of a given EMD pass the instrument and can be collected on corresponding supporting materials for subsequent nanoparticle analyses applying e.g. microscopic, immunologic or spectroscopic techniques. In our proof-of-concept study we now focus for the first time on mass spectrometric (MS) characterization of DMA size-selected material. We carried out size-selection of liposomes, vesicles consisting of a lipid bilayer and an aqueous lumen employed as carriers in e.g. pharmaceutic, cosmetic or nutritional applications. Particles of 85 nm EMD were collected on gold-coated silicon wafers. Subsequently, matrix was applied and Matrix-Assisted Laser Desorption / Ionization (MALDI) MS carried out. However, we not only focused on plain liposomes but also demonstrated the applicability of our approach for very heterogeneous low density lipoprotein (VLDL) particles, a transporter of lipid metabolism. Our novel offline hyphenation of gas-phase electrophoresis (termed nES DMA or nES GEMMA) and MALDI-MS opens the avenue to the molecular characterization of size-select nanoparticles of complex nature.
Collapse
|
20
|
Dülfer J, Kadek A, Kopicki JD, Krichel B, Uetrecht C. Structural mass spectrometry goes viral. Adv Virus Res 2019; 105:189-238. [PMID: 31522705 DOI: 10.1016/bs.aivir.2019.07.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Over the last 20 years, mass spectrometry (MS), with its ability to analyze small sample amounts with high speed and sensitivity, has more and more entered the field of structural virology, aiming to investigate the structure and dynamics of viral proteins as close to their native environment as possible. The use of non-perturbing labels in hydrogen-deuterium exchange MS allows for the analysis of interactions between viral proteins and host cell factors as well as their dynamic responses to the environment. Cross-linking MS, on the other hand, can analyze interactions in viral protein complexes and identify virus-host interactions in cells. Native MS allows transferring viral proteins, complexes and capsids into the gas phase and has broken boundaries to overcome size limitations, so that now even the analysis of intact virions is possible. Different MS approaches not only inform about size, stability, interactions and dynamics of virus assemblies, but also bridge the gap to other biophysical techniques, providing valuable constraints for integrative structural modeling of viral complex assemblies that are often inaccessible by single technique approaches. In this review, recent advances are highlighted, clearly showing that structural MS approaches in virology are moving towards systems biology and ever more experiments are performed on cellular level.
Collapse
Affiliation(s)
- Jasmin Dülfer
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
| | - Alan Kadek
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany; European XFEL GmbH, Schenefeld, Germany
| | - Janine-Denise Kopicki
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
| | - Boris Krichel
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
| | - Charlotte Uetrecht
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany; European XFEL GmbH, Schenefeld, Germany.
| |
Collapse
|
21
|
Weiss VU, Pogan R, Zoratto S, Bond KM, Boulanger P, Jarrold MF, Lyktey N, Pahl D, Puffler N, Schelhaas M, Selivanovitch E, Uetrecht C, Allmaier G. Virus-like particle size and molecular weight/mass determination applying gas-phase electrophoresis (native nES GEMMA). Anal Bioanal Chem 2019; 411:5951-5962. [PMID: 31280479 PMCID: PMC6706367 DOI: 10.1007/s00216-019-01998-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 05/29/2019] [Accepted: 06/24/2019] [Indexed: 02/04/2023]
Abstract
(Bio-)nanoparticle analysis employing a nano-electrospray gas-phase electrophoretic mobility molecular analyzer (native nES GEMMA) also known as nES differential mobility analyzer (nES DMA) is based on surface-dry analyte separation at ambient pressure. Based on electrophoretic principles, single-charged nanoparticles are separated according to their electrophoretic mobility diameter (EMD) corresponding to the particle size for spherical analytes. Subsequently, it is possible to correlate the (bio-)nanoparticle EMDs to their molecular weight (MW) yielding a corresponding fitted curve for an investigated analyte class. Based on such a correlation, (bio-)nanoparticle MW determination via its EMD within one analyte class is possible. Turning our attention to icosahedral, non-enveloped virus-like particles (VLPs), proteinaceous shells, we set up an EMD/MW correlation. We employed native electrospray ionization mass spectrometry (native ESI MS) to obtain MW values of investigated analytes, where possible, after extensive purification. We experienced difficulties in native ESI MS with time-of-flight (ToF) detection to determine MW due to sample inherent characteristics, which was not the case for charge detection (CDMS). nES GEMMA exceeds CDMS in speed of analysis and is likewise less dependent on sample purity and homogeneity. Hence, gas-phase electrophoresis yields calculated MW values in good approximation even when charge resolution was not obtained in native ESI ToF MS. Therefore, both methods-native nES GEMMA-based MW determination via an analyte class inherent EMD/MW correlation and native ESI MS-in the end relate (bio-)nanoparticle MW values. However, they differ significantly in, e.g., ease of instrument operation, sample and analyte handling, or costs of instrumentation. Graphical abstract ![]()
Collapse
Affiliation(s)
- Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164, 1060, Vienna, Austria.
| | - Ronja Pogan
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Martinistraße 52, 20251, Hamburg, Germany.,European XFEL GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - Samuele Zoratto
- Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164, 1060, Vienna, Austria
| | - Kevin M Bond
- Department of Chemistry, Indiana University, 800 E Kirkwood Ave, Bloomington, IN, 47405, USA
| | - Pascale Boulanger
- Institute for Integrative Biology of the Cell, CEA, CNRS, Université Paris-Sud, Université Paris-Saclay, 91198, Gif-sur-Yvette, France
| | - Martin F Jarrold
- Department of Chemistry, Indiana University, 800 E Kirkwood Ave, Bloomington, IN, 47405, USA
| | - Nicholas Lyktey
- Department of Chemistry, Indiana University, 800 E Kirkwood Ave, Bloomington, IN, 47405, USA
| | - Dominik Pahl
- Institute of Cellular Virology, WWU Münster, Von-Esmarch-Str. 56, 48149, Münster, Germany
| | - Nicole Puffler
- Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164, 1060, Vienna, Austria
| | - Mario Schelhaas
- Institute of Cellular Virology, WWU Münster, Von-Esmarch-Str. 56, 48149, Münster, Germany
| | - Ekaterina Selivanovitch
- Department of Chemistry, Indiana University, 800 E Kirkwood Ave, Bloomington, IN, 47405, USA
| | - Charlotte Uetrecht
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Martinistraße 52, 20251, Hamburg, Germany.,European XFEL GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - Günter Allmaier
- Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164, 1060, Vienna, Austria
| |
Collapse
|
22
|
Ashcroft AE. Mass spectrometry-based studies of virus assembly. Curr Opin Virol 2019; 36:17-24. [DOI: 10.1016/j.coviro.2019.02.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Revised: 01/31/2019] [Accepted: 02/06/2019] [Indexed: 12/21/2022]
|
23
|
Elliott AG, Harper CC, Lin HW, Williams ER. Effects of Individual Ion Energies on Charge Measurements in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:946-955. [PMID: 30430436 DOI: 10.1007/s13361-018-2094-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 10/15/2018] [Accepted: 10/15/2018] [Indexed: 06/09/2023]
Abstract
A method to correct for the effect of ion energy on charge measurements of individual ions trapped and weighed with charge detection mass spectrometry (CDMS) is demonstrated. Ions with different energies induce different signal patterns inside an electrostatic ion trap. The sum of the amplitudes of the fundamental and second harmonic frequencies in the Fourier transform of the induced signal, which has been used to obtain the ion charge, depends on both ion energy and charge. The amplitudes of the fundamental frequencies of ions increase over time as ions lose energy by collisions with background gas and solvent loss from larger ions. Model ion signals are simulated with the same time-domain amplitude at different energies and frequencies and the resulting fundamental frequency amplitudes are used to normalize real ion signals for energy and frequency effects. The fundamental frequency amplitude decreases dramatically below 20 kHz and increases by ~ 17% from the highest energy to lowest energy that is stable with a given trap potential at all frequencies. Normalizing the fundamental frequency amplitude with the modeled amplitudes removes the systematic changes in the charge measurement of polyethylene glycol (PEG) and other ions and makes it possible to signal average the amplitude over long times, which reduces the charge uncertainty to 0.04% for a PEG ion for a 500-ms measurement. This method improves charge measurement accuracy and uncertainty, which are important for high-accuracy mass measurement with CDMS. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Andrew G Elliott
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA
| | - Conner C Harper
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA
| | - Haw-Wei Lin
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA
| | - Evan R Williams
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA.
| |
Collapse
|
24
|
Weiss VU, Wieland K, Schwaighofer A, Lendl B, Allmaier G. Native Nano-electrospray Differential Mobility Analyzer (nES GEMMA) Enables Size Selection of Liposomal Nanocarriers Combined with Subsequent Direct Spectroscopic Analysis. Anal Chem 2019; 91:3860-3868. [PMID: 30735037 PMCID: PMC6427476 DOI: 10.1021/acs.analchem.8b04252] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
![]()
Gas-phase
electrophoresis employing a nano-electrospray differential
mobility analyzer (nES DMA), aka gas-phase electrophoretic mobility
molecular analyzer (nES GEMMA), enables nanoparticle separation in
the gas-phase according to their surface-dry diameter with number-based
concentration detection. Moreover, particles in the nanometer
size range can be collected after size selection on supporting materials.
It has been shown by subsequent analyses employing orthogonal methods,
for instance, microscopic or antibody-based techniques, that the surface
integrity of collected analytes remains intact. Additionally, native
nES GEMMA demonstrated its applicability for liposome characterization.
Liposomes are nanometer-sized, biodegradable, and rather labile carriers
(nanoobjects) consisting of a lipid bilayer encapsulating an aqueous
lumen. In nutritional and pharmaceutical applications, these vesicles
allow shielded, targeted transport and sustained release of bioactive
cargo material. To date, cargo quantification is based on bulk measurements
after bilayer rupture. In this context, we now compare capillary electrophoresis
and spectroscopic characterization of vesicles in solution (bulk measurements)
to the possibility of spectroscopic investigation of individual, size-separated/collected
liposomes after nES GEMMA. Surface-dried, size-selected vesicles were
collected intact on calcium fluoride (CaF2) substrates
and zinc selenide (ZnSe) prisms, respectively, for subsequent spectroscopic
investigation. Our proof-of-principle study demonstrates that the
off-line hyphenation of gas-phase electrophoresis and confocal Raman
spectroscopy allows detection of isolated, nanometer-sized soft material/objects.
Additionally, atomic force microscopy-infrared spectroscopy (AFM-IR)
as an advanced spectroscopic system was employed to access molecule-specific
information with nanoscale lateral resolution. The off-line hyphenation
of nES GEMMA and AFM-IR is introduced to enable chemical imaging of
single, i.e., individual, liposome particles.
Collapse
Affiliation(s)
- Victor U Weiss
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Karin Wieland
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Andreas Schwaighofer
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| | - Guenter Allmaier
- Institute of Chemical Technologies and Analytics , Vienna University of Technology (TU Wien) , A-1060 Vienna , Austria
| |
Collapse
|
25
|
Kondylis P, Schlicksup CJ, Zlotnick A, Jacobson SC. Analytical Techniques to Characterize the Structure, Properties, and Assembly of Virus Capsids. Anal Chem 2019; 91:622-636. [PMID: 30383361 PMCID: PMC6472978 DOI: 10.1021/acs.analchem.8b04824] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Panagiotis Kondylis
- Department of Chemistry, Indiana University, Bloomington, IN 47405-7102, USA
| | - Christopher J. Schlicksup
- Department of Molecular and Cellular Biochemistry, Indiana University, Bloomington, IN 47405-7102, USA
| | - Adam Zlotnick
- Department of Molecular and Cellular Biochemistry, Indiana University, Bloomington, IN 47405-7102, USA
| | - Stephen C. Jacobson
- Department of Chemistry, Indiana University, Bloomington, IN 47405-7102, USA
| |
Collapse
|
26
|
Elliott AG, Harper CC, Lin HW, Williams ER. Mass, mobility and MS n measurements of single ions using charge detection mass spectrometry. Analyst 2018. [PMID: 28636005 DOI: 10.1039/c7an00618g] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Charge detection mass spectrometry is used to measure the mass, charge, MSn and mobility of an individual ion produced by electrospray ionization of a 8 MDa polyethylene glycol sample. The charge detection mass spectrometer is an electrostatic ion trap that uses cone electrodes and a single tube detector and can detect ions for up to the full trapping time of 4.0 s. The time-domain signal induced on the detector tube by a single multiply charged ion can be complex owing to sequential fragmentation of the original precursor ion as well as increasing oscillation frequencies of the single ion owing to collisions with background gas that reduce the kinetic energy of the ion inside the trap. Simulations show that the ratio of the time for the ion to turn around inside the cone region of the trap to the time for the ion to travel through the detector tube is constant with m/z and increases with the ion energy per charge. By measuring this ratio, the kinetic energy of an ion can be obtained with good precision (∼1%) and this method to measure ion kinetic energies eliminates the necessity of ion energy selection prior to trapping for high precision mass measurement of large molecules in complex mixtures. This method also makes it possible to measure the masses of each sequential fragment ion formed from the original precursor ion. MS7 of a single multiply charged PEG molecule is demonstrated, and from these ion energy measurements and effects of collisions on the ion motion inside the trap, information about the ion mobility of the precursor ion and its fragments is obtained.
Collapse
Affiliation(s)
- Andrew G Elliott
- Department of Chemistry, University of California, Berkeley, California 94720-1460, USA.
| | - Conner C Harper
- Department of Chemistry, University of California, Berkeley, California 94720-1460, USA.
| | - Haw-Wei Lin
- Department of Chemistry, University of California, Berkeley, California 94720-1460, USA.
| | - Evan R Williams
- Department of Chemistry, University of California, Berkeley, California 94720-1460, USA.
| |
Collapse
|
27
|
Weiss VU, Golesne M, Friedbacher G, Alban S, Szymanski WW, Marchetti‐Deschmann M, Allmaier G. Size and molecular weight determination of polysaccharides by means of nano electrospray gas-phase electrophoretic mobility molecular analysis (nES GEMMA). Electrophoresis 2018; 39:1142-1150. [PMID: 29465753 PMCID: PMC6001696 DOI: 10.1002/elps.201700382] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 02/06/2018] [Accepted: 02/07/2018] [Indexed: 12/16/2022]
Abstract
Size, size distribution and molecular weight (MW) determination of nanoparticles and that are for example large polymers, are of great interest and pose an analytical challenge. In this context, nano electrospray gas-phase electrophoretic mobility molecular analysis (nES GEMMA) is a valuable tool with growing impact. Separation of single-charged analytes according to their electrophoretic mobility diameter (EMD) starting from single-digit EMDs up to several hundred nm diameters is possible. In case of spherical analytes, the EMD corresponds to the dry nanoparticle size. Additionally, the instrument is capable of number-based, single-particle detection following the recommendation of the European Commission for nanoparticle characterization (2011/696/EU). In case an EMD/MW correlation for a particular compound class (based on availability of well-defined standards) exists, a nanoparticle's MW can be determined from its EMD. In the present study, we focused on nES GEMMA of linear and branched, water-soluble polysaccharides forming nanoparticles and were able to obtain spectra for both analyte classes regarding single-charged species. Based on EMDs for corresponding analytes, an excellent EMD/MW correlation could be obtained in case of the branched natural polymer (dextran). This enables the determination of dextran MWs from nES GEMMA spectra despite high analyte polydispersity and in a size/MW range, where classical mass spectrometry is limited. EMD/MW correlations based on linear (pullulans, oat-ß-glucans) polymers were significantly different, possibly indicating challenges in the exact MW determination of these compounds by, for example, chromatographic and light scattering means. Despite these observations, nES GEMMA of linear, monosaccharide-based polymers enabled the determination of size and size-distribution of such dry bionanoparticles.
Collapse
Affiliation(s)
- Victor U. Weiss
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | - Monika Golesne
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
- Department of Mechanical and Process EngineeringUniversity of KaiserslauternKaiserslauternGermany
| | - Gernot Friedbacher
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| | | | | | | | - Günter Allmaier
- Institute of Chemical Technologies and AnalyticsTU Wien (Vienna University of Technology)ViennaAustria
| |
Collapse
|
28
|
Pogan R, Schneider C, Reimer R, Hansman G, Uetrecht C. Norovirus-like VP1 particles exhibit isolate dependent stability profiles. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2018; 30:064006. [PMID: 29282349 PMCID: PMC7104913 DOI: 10.1088/1361-648x/aaa43b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 12/19/2017] [Accepted: 12/28/2017] [Indexed: 05/08/2023]
Abstract
Noroviruses are the main cause of viral gastroenteritis with new variants emerging frequently. There are three norovirus genogroups infecting humans. These genogroups are divided based on the sequence of their major capsid protein, which is able to form virus-like particles (VLPs) when expressed recombinantly. VLPs of the prototypical GI.1 Norwalk virus are known to disassemble into specific capsid protein oligomers upon alkaline treatment. Here, native mass spectrometry and electron microscopy on variants of GI.1 and of GII.17 were performed, revealing differences in terms of stability between these groups. Beyond that, these experiments indicate differences even between variants within a genotype. The capsid stability was monitored in different ammonium acetate solutions varying both in ionic strength and pH. The investigated GI.1 West Chester isolate showed comparable disassembly profiles to the previously studied GI.1 Norwalk virus isolate. However, differences were observed with the West Chester being more sensitive to alkaline pH. In stark contrast to that, capsids of the variant belonging to the currently prevalent genogroup GII were stable in all tested conditions. Both variants formed smaller capsid particles already at neutral pH. Certain amino acid substitutions in the S domain of West Chester relative to the Norwalk virus potentially result in the formation of these T = 1 capsids.
Collapse
Affiliation(s)
- Ronja Pogan
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
| | - Carola Schneider
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
| | - Rudolph Reimer
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
| | - Grant Hansman
- Department of Infectious Diseases, Virology, Heidelberg University, Heidelberg, Germany
- Schaller Research Group at the University of Heidelberg and the DKFZ, Heidelberg, Germany
| | - Charlotte Uetrecht
- Heinrich Pette Institute, Leibniz Institute for Experimental Virology, Hamburg, Germany
- European XFEL, Schenefeld, Germany
| |
Collapse
|
29
|
Belov AM, Viner R, Santos MR, Horn DM, Bern M, Karger BL, Ivanov AR. Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2614-2634. [PMID: 28875426 PMCID: PMC5709234 DOI: 10.1007/s13361-017-1781-1] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 08/09/2017] [Accepted: 08/09/2017] [Indexed: 05/04/2023]
Abstract
Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein-protein and protein-ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes). Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Arseniy M Belov
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA
| | - Rosa Viner
- Thermo Fisher Scientific, San Jose, CA, 95134, USA
| | | | - David M Horn
- Thermo Fisher Scientific, San Jose, CA, 95134, USA
| | | | - Barry L Karger
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA
| | - Alexander R Ivanov
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA.
| |
Collapse
|
30
|
Belov AM, Viner R, Santos MR, Horn DM, Bern M, Karger BL, Ivanov AR. Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2614-2634. [PMID: 28875426 DOI: 10.1007/s13361-13017-11781-13361] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 08/09/2017] [Accepted: 08/09/2017] [Indexed: 05/25/2023]
Abstract
Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein-protein and protein-ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes). Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Arseniy M Belov
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA
| | - Rosa Viner
- Thermo Fisher Scientific, San Jose, CA, 95134, USA
| | | | - David M Horn
- Thermo Fisher Scientific, San Jose, CA, 95134, USA
| | | | - Barry L Karger
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA
| | - Alexander R Ivanov
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA.
| |
Collapse
|
31
|
Allmaier G, Blaas D, Bliem C, Dechat T, Fedosyuk S, Gösler I, Kowalski H, Weiss VU. Monolithic anion-exchange chromatography yields rhinovirus of high purity. J Virol Methods 2017; 251:15-21. [PMID: 28966037 DOI: 10.1016/j.jviromet.2017.09.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 09/27/2017] [Accepted: 09/27/2017] [Indexed: 11/26/2022]
Abstract
For vaccine development, 3D-structure determination, direct fluorescent labelling, and numerous other studies, homogeneous virus preparations of high purity are essential. Working with human rhinoviruses (RVs), members of the picornavirus family and the main cause of generally mild respiratory infections, we noticed that our routine preparations appeared highly pure on analysis by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), exclusively showing the four viral capsid proteins (VPs). However, the preparations turned out to contain substantial amounts of contaminating material when analyzed by orthogonal analytical methods including capillary zone electrophoresis, nano electrospray gas-phase electrophoretic mobility molecular analysis (nES GEMMA), and negative stain transmission electron microscopy (TEM). Because these latter analyses are not routine to many laboratories, the above contaminations might remain unnoticed and skew experimental results. By using human rhinovirus serotype A2 (RV-A2) as example we report monolithic anion-exchange chromatography (AEX) as a last polishing step in the purification and demonstrate that it yields infective, highly pure, virus (RV-A2 in the respective fractions was confirmed by peptide mass fingerprinting) devoid of foreign material as judged by the above criteria.
Collapse
Affiliation(s)
- Günter Allmaier
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna, Austria
| | - Dieter Blaas
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Vienna, Austria
| | - Christina Bliem
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna, Austria
| | - Thomas Dechat
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Vienna, Austria
| | - Sofiya Fedosyuk
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Vienna, Austria
| | - Irene Gösler
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Vienna, Austria
| | - Heinrich Kowalski
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Vienna, Austria
| | - Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna, Austria.
| |
Collapse
|
32
|
Doppler C, Arnhard K, Dumfarth J, Heinz K, Messner B, Stern C, Koal T, Klavins K, Danzl K, Pitterl F, Grimm M, Oberacher H, Bernhard D. Metabolomic profiling of ascending thoracic aortic aneurysms and dissections - Implications for pathophysiology and biomarker discovery. PLoS One 2017; 12:e0176727. [PMID: 28467501 PMCID: PMC5415060 DOI: 10.1371/journal.pone.0176727] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Accepted: 04/14/2017] [Indexed: 02/04/2023] Open
Abstract
Objective Our basic understanding of ascending thoracic aortic aneurysm (ATAA) pathogenesis is still very limited, hampering early diagnosis, risk prediction, and development of treatment options. “Omics”-technologies, ideal to reveal tissue alterations from the normal physiological state due to disease have hardly been applied in the field. Using a metabolomic approach, with this study the authors seek to define tissue differences between controls and various forms of ATAAs. Methods Using a targeted FIA-MS/MS metabolomics approach, we analysed and compared the metabolic profiles of ascending thoracic aortic wall tissue of age-matched controls (n = 8), bicuspid aortic valve-associated aneurysms (BAV-A; n = 9), tricuspid aortic valve-associated aneurysms (TAV-A; n = 14), and tricuspid aortic valve-associated aortic dissections (TAV-Diss; n = 6). Results With sphingomyelin (SM) (OH) C22:2, SM C18:1, SM C22:1, and SM C24:1 only 4 out of 92 detectable metabolites differed significantly between controls and BAV-A samples. Between controls and TAV-Diss samples only phosphatidylcholine (PC) ae C32:1 differed. Importantly, our analyses revealed a general increase in the amount of total sphingomyelin levels in BAV-A and TAV-Diss samples compared to controls. Conclusions Significantly increased levels of sphingomyelins in BAV-A and TAV-Diss samples compared to controls may argue for a repression of sphingomyelinase activity and the sphingomyelinase-ceramide pathway, which may result in an inhibition of tissue regeneration; a potential basis for disease initiation and progression.
Collapse
Affiliation(s)
- Christian Doppler
- Cardiac Surgery Research Laboratory, University Clinic for Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
- Cardiac, Vascular, and Thoracic Surgery, Medical Faculty, Johannes-Kepler University, Linz, Austria
| | - Kathrin Arnhard
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Innsbruck, Austria
| | - Julia Dumfarth
- Cardiac Surgery Research Laboratory, University Clinic for Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
| | - Katharina Heinz
- Cardiac Surgery Research Laboratory, University Clinic for Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
| | - Barbara Messner
- Department of Cardiac Surgery, Vienna Medical University, Vienna, Austria
| | - Christian Stern
- Department of Cardiac Surgery, Vienna Medical University, Vienna, Austria
| | | | | | - Katarina Danzl
- Cardiac Surgery Research Laboratory, University Clinic for Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
| | - Florian Pitterl
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Innsbruck, Austria
| | - Michael Grimm
- Cardiac Surgery Research Laboratory, University Clinic for Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
| | - Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Innsbruck, Austria
| | - David Bernhard
- Cardiac Surgery Research Laboratory, University Clinic for Cardiac Surgery, Innsbruck Medical University, Innsbruck, Austria
- Cardiac, Vascular, and Thoracic Surgery, Medical Faculty, Johannes-Kepler University, Linz, Austria
- * E-mail:
| |
Collapse
|
33
|
Forsberg E, Fang M, Siuzdak G. Staying Alive: Measuring Intact Viable Microbes with Electrospray Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:14-20. [PMID: 27456857 PMCID: PMC5177535 DOI: 10.1007/s13361-016-1440-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 06/08/2016] [Accepted: 06/19/2016] [Indexed: 06/06/2023]
Abstract
Mass spectrometry has traditionally been the technology of choice for small molecule analysis, making significant inroads into metabolism, clinical diagnostics, and pharmacodynamics since the 1960s. In the mid-1980s, with the discovery of electrospray ionization (ESI) for biomolecule analysis, a new door opened for applications beyond small molecules. Initially, proteins were widely examined, followed by oligonucleotides and other nonvolatile molecules. Then in 1991, three intriguing studies reported using mass spectrometry to examine noncovalent protein complexes, results that have been expanded on for the last 25 years. Those experiments also raised the questions: How soft is ESI, and can it be used to examine even more complex interactions? Our lab addressed these questions with the analyses of viruses, which were initially tested for viability following electrospray ionization and their passage through a quadrupole mass analyzer by placing them on an active medium that would allow them to propagate. This observation has been replicated on multiple different systems, including experiments on an even bigger microbe, a spore. The question of analysis was also addressed in the early 2000s with charge detection mass spectrometry. This unique technology could simultaneously measure mass-to-charge and charge, allowing for the direct determination of the mass of a virus. More recent experiments on spores and enveloped viruses have given us insight into the range of mass spectrometry's capabilities (reaching 100 trillion Da), beginning to answer fundamental questions regarding the complexity of these organisms beyond proteins and genes, and how small molecules are integral to these supramolecular living structures. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Erica Forsberg
- Scripps Center for Metabolomics, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA, 92037, USA
| | - Mingliang Fang
- Scripps Center for Metabolomics, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA, 92037, USA
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Gary Siuzdak
- Scripps Center for Metabolomics, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA, 92037, USA.
- Departments of Chemistry, Molecular and Computational Biology, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA, 92037, USA.
| |
Collapse
|
34
|
Pierson EE, Keifer DZ, Asokan A, Jarrold MF. Resolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry. Anal Chem 2016; 88:6718-25. [PMID: 27310298 PMCID: PMC6537880 DOI: 10.1021/acs.analchem.6b00883] [Citation(s) in RCA: 109] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Recombinant adeno-associated viruses (AAVs) are promising vectors for human gene therapy. However, current methods for evaluating AAV particle populations and vector purity are inefficient and low resolution. Here, we show that charge detection mass spectrometry (CDMS) can resolve capsids that contain the entire vector genome from those that contain partial genomes and from empty capsids. Measurements were performed for both single-stranded and self-complementary genomes. The self-complementary AAV vector preparation appears to contain particles with partially truncated genomes averaging at half the genome length. Comparison to results from electron microscopy with manual particle counting shows that CDMS has no significant mass discrimination in the relevant mass range (after a correction for the ion velocity is taken into account). Empty AAV capsids are intrinsically heterogeneous, and capsids from different sources have slightly different masses. However, the average masses of both the empty and full capsids are in close agreement with expected values. Mass differences between the empty and full capsids for both single-stranded and self-complementary AAV vectors indicate that the genomes are largely packaged without counterions.
Collapse
Affiliation(s)
- Elizabeth E. Pierson
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - David. Z. Keifer
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Aravind Asokan
- Gene Therapy Center, University of North Carolina, Chapel Hill, North Carolina 27599, United States
| | - Martin F. Jarrold
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| |
Collapse
|
35
|
Keifer DZ, Motwani T, Teschke CM, Jarrold MF. Acquiring Structural Information on Virus Particles with Charge Detection Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:1028-36. [PMID: 27020925 PMCID: PMC5095694 DOI: 10.1007/s13361-016-1362-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/04/2016] [Accepted: 02/06/2016] [Indexed: 05/10/2023]
Abstract
Charge detection mass spectrometry (CDMS) is a single-molecule technique particularly well-suited to measuring the mass and charge distributions of heterogeneous, MDa-sized ions. In this work, CDMS has been used to analyze the assembly products of two coat protein variants of bacteriophage P22. The assembly products show broad mass distributions extending from 5 to 15 MDa for A285Y and 5 to 25 MDa for A285T coat protein variants. Because the charge of large ions generated by electrospray ionization depends on their size, the charge can be used to distinguish hollow shells from more compact structures. A285T was found to form T = 4 and T = 7 procapsids, and A285Y makes a small number of T = 3 and T = 4 procapsids. Owing to the decreased stability of the A285Y and A285T particles, chemical cross-linking was required to stabilize them for electrospray CDMS.Graphical Abstract.
Collapse
Affiliation(s)
- David Z Keifer
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA
| | - Tina Motwani
- Department of Molecular and Cell Biology, University of Connecticut, Storrs, CT, 06269, USA
| | - Carolyn M Teschke
- Department of Molecular and Cell Biology, University of Connecticut, Storrs, CT, 06269, USA
- Department of Chemistry, University of Connecticut, Storrs, CT, 06269, USA
| | - Martin F Jarrold
- Department of Chemistry, Indiana University, Bloomington, IN, 47405, USA.
| |
Collapse
|
36
|
Weiss VU, Bliem C, Gösler I, Fedosyuk S, Kratzmeier M, Blaas D, Allmaier G. In vitro RNA release from a human rhinovirus monitored by means of a molecular beacon and chip electrophoresis. Anal Bioanal Chem 2016; 408:4209-17. [PMID: 27020928 PMCID: PMC4875947 DOI: 10.1007/s00216-016-9459-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 02/19/2016] [Accepted: 03/01/2016] [Indexed: 11/28/2022]
Abstract
Liquid-phase electrophoresis either in the classical capillary format or miniaturized (chip CE) is a valuable tool for quality control of virus preparations and for targeting questions related to conformational changes of viruses during infection. We present an in vitro assay to follow the release of the RNA genome from a human rhinovirus (common cold virus) by using a molecular beacon (MB) and chip CE. The MB, a probe that becomes fluorescent upon hybridization to a complementary sequence, was designed to bind close to the 3′ end of the viral genome. Addition of Trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), a well-known additive for reduction of bleaching and blinking of fluorophores in fluorescence microscopy, to the background electrolyte increased the sensitivity of our chip CE set-up. Hence, a fast, sensitive and straightforward method for the detection of viral RNA is introduced. Additionally, challenges of our assay will be discussed. In particular, we found that (i) desalting of virus preparations prior to analysis increased the recorded signal and (ii) the MB–RNA complex signal decreased with the time of virus storage at −70 °C. This suggests that 3′-proximal sequences of the viral RNA, if not the whole genome, underwent degradation during storage and/or freezing and thawing. In summary, we demonstrate, for two independent virus batches, that chip electrophoresis can be used to monitor MB hybridization to RNA released upon incubation of the native virus at 56 °C. Schematic of the study strategy: RNA released from HRV-A2 is detected by chip electrophoresis through the increase in fluorescence after genom complexation to a cognate molecular beacon ![]()
Collapse
Affiliation(s)
- Victor U Weiss
- Institute of Chemical Technologies and Analytics, Vienna University of Technology (TU Wien), Getreidemarkt 9/164, 1060, Vienna, Austria
| | - Christina Bliem
- Institute of Chemical Technologies and Analytics, Vienna University of Technology (TU Wien), Getreidemarkt 9/164, 1060, Vienna, Austria
| | - Irene Gösler
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Dr. Bohr-Gasse 9, 1030, Vienna, Austria
| | - Sofiya Fedosyuk
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Dr. Bohr-Gasse 9, 1030, Vienna, Austria
| | - Martin Kratzmeier
- Agilent Technologies, Hewlett-Packard-Straße 8, 76337, Waldbronn, Germany
| | - Dieter Blaas
- Department of Medical Biochemistry, Medical University of Vienna, Vienna Biocenter, Dr. Bohr-Gasse 9, 1030, Vienna, Austria
| | - Günter Allmaier
- Institute of Chemical Technologies and Analytics, Vienna University of Technology (TU Wien), Getreidemarkt 9/164, 1060, Vienna, Austria.
| |
Collapse
|