1
|
Boelrijk J, Molenaar SRA, Bos TS, Dahlseid TA, Ensing B, Stoll DR, Forré P, Pirok BWJ. Enhancing LC×LC separations through multi-task Bayesian optimization. J Chromatogr A 2024; 1726:464941. [PMID: 38749274 DOI: 10.1016/j.chroma.2024.464941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 04/17/2024] [Accepted: 04/22/2024] [Indexed: 05/23/2024]
Abstract
Method development in comprehensive two-dimensional liquid chromatography (LC×LC) is a challenging process. The interdependencies between the two dimensions and the possibility of incorporating complex gradient profiles, such as multi-segmented gradients or shifting gradients, make trial-and-error method development time-consuming and highly dependent on user experience. Retention modeling and Bayesian optimization (BO) have been proposed as solutions to mitigate these issues. However, both approaches have their strengths and weaknesses. On the one hand, retention modeling, which approximates true retention behavior, depends on effective peak tracking and accurate retention time and width predictions, which are increasingly challenging for complex samples and advanced gradient assemblies. On the other hand, Bayesian optimization may require many experiments when dealing with many adjustable parameters, as in LC×LC. Therefore, in this work, we investigate the use of multi-task Bayesian optimization (MTBO), a method that can combine information from both retention modeling and experimental measurements. The algorithm was first tested and compared with BO using a synthetic retention modeling test case, where it was shown that MTBO finds better optima with fewer method-development iterations than conventional BO. Next, the algorithm was tested on the optimization of a method for a pesticide sample and we found that the algorithm was able to improve upon the initial scanning experiments. Multi-task Bayesian optimization is a promising technique in situations where modeling retention is challenging, and the high number of adjustable parameters and/or limited optimization budget makes traditional Bayesian optimization impractical.
Collapse
Affiliation(s)
- Jim Boelrijk
- AI4Science Lab, Informatics Institute, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands; AMLab, Informatics Institute, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands.
| | - Stef R A Molenaar
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, De Boelelaan 1085, Amsterdam, 1081 HV, The Netherlands; Analytical Chemistry Group, Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands
| | - Tijmen S Bos
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, De Boelelaan 1085, Amsterdam, 1081 HV, The Netherlands; Analytical Chemistry Group, Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands
| | - Tina A Dahlseid
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, MN 56082, United States
| | - Bernd Ensing
- AI4Science Lab, Informatics Institute, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands; Computational Chemistry Group, Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands
| | - Dwight R Stoll
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, MN 56082, United States
| | - Patrick Forré
- AI4Science Lab, Informatics Institute, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands; AMLab, Informatics Institute, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands
| | - Bob W J Pirok
- AI4Science Lab, Informatics Institute, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands; Analytical Chemistry Group, Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, Science Park 904, 1098 XH, The Netherlands.
| |
Collapse
|
2
|
Aly AA, Górecki T. Two-dimensional liquid chromatography with reversed phase in both dimensions: A review. J Chromatogr A 2024; 1721:464824. [PMID: 38522405 DOI: 10.1016/j.chroma.2024.464824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 03/14/2024] [Accepted: 03/16/2024] [Indexed: 03/26/2024]
Abstract
Two-dimensional liquid chromatography (2D-LC), and in particular comprehensive two-dimensional liquid chromatography (LC×LC), offers increased peak capacity, resolution and selectivity compared to one-dimensional liquid chromatography. It is commonly accepted that the technique produces the best results when the separation mechanisms in the two dimensions are completely orthogonal; however, the use of similar separation mechanisms in both dimensions has been gaining popularity as it helps avoid difficulties related to mobile phase incompatibility and poor column efficiency. The remarkable advantages of using reversed phase in both dimensions (RPLC×RPLC) over other separation mechanisms made it a promising technique in the separation of complex samples. This review discusses some physical and practical considerations in method development for 2D-LC involving the use of RP in both dimensions. In addition, an extensive overview is presented of different applications that relied on RPLC×RPLC and 2D-LC with reversed phase column combinations to separate components of complex samples in different fields including food analysis, natural product analysis, environmental analysis, proteomics, lipidomics and metabolomics.
Collapse
Affiliation(s)
- Alshymaa A Aly
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Menia Governorate, Arab Republic of Egypt; Department of Chemistry, University of Waterloo, ON, Canada
| | - Tadeusz Górecki
- Department of Chemistry, University of Waterloo, ON, Canada.
| |
Collapse
|
3
|
Aebischer MK, Chapel S, Guillarme D, Heinisch S. Theoretical and practical guidelines for solvent dilution between the two dimensions in online comprehensive two-dimensional liquid chromatography. J Chromatogr A 2024; 1718:464725. [PMID: 38364617 DOI: 10.1016/j.chroma.2024.464725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/23/2024] [Accepted: 02/07/2024] [Indexed: 02/18/2024]
Abstract
Online comprehensive two-dimensional liquid chromatography (online LC x LC) has become increasingly popular. Among the different chromatographic modes that can be combined, hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) are particularly interesting because they offer a high degree of orthogonality. However, this combination remains complex due to the incompatibility of the solvents in the two dimensions. To avoid this problem, it is possible to dilute the first dimension (1D) effluent with (zdilution -1) volumes of a weaker solvent added to one volume of 1D-effluent, where zdilution represents the extent to which the fraction volume has been multiplied. This can be done using either active solvent modulation technology or an additional pump, prior to the second dimension analysis. The objective of this study was to develop theoretical models to predict whether or not dilution can be effective, and, if so, what is the minimum zdilution value required. This approach is based on the calculation of the ratio (called xdilution) between the peak standard deviation due to the injection process and the peak standard deviation in the absence of extra-column dispersion. xdilution was calculated from theoretical relationships and plotted as a function of zdilution, to predict the value required to obtain good peak shapes for the compound of interest. The maximum xdilution value was found to be of the order of 1 for chromatographically acceptable peak shapes. The proposed theoretical approach was experimentally validated on a number of representative small molecules and peptides. Agreement between experimental results and theoretical models was very high, especially for small molecules. Finally, it is shown that this approach helps to predict the most appropriate set of conditions in HILIC x RPLC, depending on the compounds to be separated.
Collapse
Affiliation(s)
- Megane K Aebischer
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland
| | - Soraya Chapel
- Laboratoire SMS-EA3233, Université Rouen Normandie, FR3038 INC3M, Unirouen, Place Emile Blondel, F-76821, Mont-Saint-Aignan, France
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280 CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| |
Collapse
|
4
|
Kochale K, Cunha R, Teutenberg T, Schmidt TC. Development of a column switching for direct online enrichment and separation of polar and nonpolar analytes from aqueous matrices. J Chromatogr A 2024; 1714:464554. [PMID: 38065029 DOI: 10.1016/j.chroma.2023.464554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 01/05/2024]
Abstract
Trace substances in surface waters may threaten health and pose a risk for the aquatic environment. Moreover, separation and detection by instrumental analysis is challenging due to the low concentration and the wide range of polarities. Separation of polar and nonpolar analytes can be achieved by using stationary phases with different selectivity. Lower limits of detection of trace substances can be obtained by offline enrichment on solid phase materials. However, these practices require substantial effort and are time consuming and costly. Therefore, in this study, a column switching was developed to enrich and separate both polar and nonpolar analytes by an on-column large volume injection of aqueous samples. The column switching can significantly reduce the effort and time for analyzing trace substances without compromising on separation and detection. A reversed phase (RP) column is used to trap the nonpolar analytes. The polar analytes are enriched on a porous graphitized carbon column (PGC) coupled serially behind the RP column. A novel valve switching system is implemented to enable elution of the nonpolar analytes from the RP column and, subsequently, elution of polar analytes from the PGC column and separation on a hydrophilic interaction liquid chromatography (HILIC) column. To enable separation of polar analytes dissolved in an aqueous matrix by HILIC, the water plug that is flushed from the PGC column is diluted by dosing organic solvent directly upstream of the HILIC column. The developed method was tested by applying target analysis and non-target screening, highlighting the advantage to effectively separate and detect both polar and nonpolar compounds in a single chromatographic run. In the target analysis, the analytes, with a logD at pH 3 ranging from -2.8 to + 4.5, could be enriched and separated. Besides the 965 features in the RP phase, 572 features from real wastewater were observed in the HILIC phase which would otherwise elute in the void time in conventional one-dimensional RP methods.
Collapse
Affiliation(s)
- Kjell Kochale
- Institut für Umwelt & Energie, Technik & Analytik e. V. (IUTA), Bliersheimer Str. 58-60, 47229 Duisburg, Germany; Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141 Essen, Germany
| | - Ricardo Cunha
- Institut für Umwelt & Energie, Technik & Analytik e. V. (IUTA), Bliersheimer Str. 58-60, 47229 Duisburg, Germany
| | - Thorsten Teutenberg
- Institut für Umwelt & Energie, Technik & Analytik e. V. (IUTA), Bliersheimer Str. 58-60, 47229 Duisburg, Germany.
| | - Torsten C Schmidt
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141 Essen, Germany
| |
Collapse
|
5
|
Pardon M, Reis R, de Witte P, Chapel S, Cabooter D. Detailed comparison of in-house developed and commercially available heart-cutting and selective comprehensive two-dimensional liquid chromatography systems. J Chromatogr A 2024; 1713:464565. [PMID: 38096685 DOI: 10.1016/j.chroma.2023.464565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 11/21/2023] [Accepted: 12/05/2023] [Indexed: 01/08/2024]
Abstract
Recently, two-dimensional liquid chromatography (2D-LC) has become a popular approach to analyze complex samples. This is partly due to the introduction of commercial 2D-LC systems. In the past, 2D-LC was carried out on in-house developed setups, typically consisting of several switching valves and sample loops as the interface between the two dimensions. Commercial systems usually offer different 2D-LC modes in combination with specialized software to operate the instrument and analyze the data. This makes them highly user-friendly, however, at an increased cost compared to in-house developed setups. This study aims to make a comparison between an in-house developed 2D-LC setup and a commercially available 2D-LC instrument. The comparison is made based on experimental differences, in addition to more general differences, including cost price, flexibility, and ease of operation. Special attention is also paid to the different strategies to deal with the mobile phase incompatibility between the highly orthogonal separation mechanisms considered in this work: hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC). For the commercial 2D-LC instrument, this is done using active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension column before transfer to the second dimension (2D) column. For the in-house developed setup, a combination of restriction capillaries and a trap column is used. Using a sample of 28 compounds with a large polarity range, peak shapes and recoveries of the 2D-chromatograms are compared for both setups. For early eluting compounds, the selective comprehensive approach, currently only possible on the commercial 2D-LC instrument, results in the best peak shapes and recoveries, however, at the cost of an increased analysis time. In general, depending on the analytical goal (single heart-cut versus full-comprehensive 2D-LC), an in-house developed system can be satisfactory for the analysis of specific target compounds/samples. For more complex problems, it can be interesting to use a more specialized commercial 2D-LC instrument. Overall, this comparison study provides advice for analytical scientists, who are considering to use 2D-LC, on the type of equipment to consider, depending on the needs of their particular applications.
Collapse
Affiliation(s)
- Marie Pardon
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium; Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Rafael Reis
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Peter de Witte
- Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Soraya Chapel
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Deirdre Cabooter
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium.
| |
Collapse
|
6
|
Caño-Carrillo I, Martínez-Piernas AB, Gilbert-López B, Molina-Díaz A, García-Reyes JF. Simultaneous analysis of highly polar and multi-residue-type pesticides by heart-cutting 2D-LC-MS. Talanta 2024; 266:124918. [PMID: 37454518 DOI: 10.1016/j.talanta.2023.124918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 07/03/2023] [Accepted: 07/05/2023] [Indexed: 07/18/2023]
Abstract
Liquid chromatography-mass spectrometry (LC-MS) is currently the gold-standard technique for the analysis of non-volatile small organic molecules. However, one-dimensional liquid chromatography (1D-LC) cannot efficiently deal with mixtures of analytes with different physicochemical properties and, thus, specific chromatographic behaviour. As an alternative, this work proposes a two-dimensional liquid chromatography/high-resolution mass spectrometry (2D-LC-HRMS) approach for the simultaneous analysis of compounds with different polarities. It is based on the combination of hydrophilic interaction liquid chromatography (HILIC) in the first dimension (1D) and reversed-phase chromatography (RPLC) in the second dimension (2D), employing the heart-cutting methodology. The coupling between 1D and 2D was performed by a multiple heart-cutting (MHC) interface equipped with an active solvent modulation (ASM) valve. The aim of the study was the development of a 2D-LC methodology able to (i) acquire the 1D and 2D content by MS in a single analytical run, avoiding the loss of information caused by the MHC algorithm for filling the sampling loops; (ii) overcome the breakthrough problem caused by solvent incompatibility, modifying the 2D gradient during the ASM phase for this purpose. To evaluate the 2D-LC approach, pesticide residue analysis was proposed, selecting 20 pesticides covering a wide range of polarities (log Kow from -3.2 to 4.3) and including some of the so-called single residue method pesticides because of the difficulty of including them in 1D-LC multi-residue methods with satisfactory chromatographic resolution. The proposed strategy was to transfer in a single cut the void volume from the HILIC separation (consisting of the nonpolar pesticides) to the 2D for analysis under RPLC conditions. The developed assembly was assessed in a vegetable matrix (tomato) employing a hybrid QuEChERS/QuPPe sample treatment based on acetonitrile and methanol extraction. The proposed setup may be extended for 2D-LC applications where it is essential to acquire the entire content of both dimensions in a single data file just by coupling a selection valve to the MHC interface.
Collapse
Affiliation(s)
- Irene Caño-Carrillo
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain
| | - Ana B Martínez-Piernas
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain; University Research Institute for Olives Grove and Olive Oil, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain; University Research Institute for Olives Grove and Olive Oil, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain
| | - Juan F García-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain; University Research Institute for Olives Grove and Olive Oil, University of Jaén, Campus Las Lagunillas, 23071, Jaén, Spain.
| |
Collapse
|
7
|
Guo R, Zhong Q, Liu J, Bai P, Wang Z, Kou J, Chen P, Zhang J, Zhang B. Polarity-extended liquid chromatography-triple quadrupole mass spectrometry for simultaneous hydrophilic and hydrophobic metabolite analysis. Anal Chim Acta 2023; 1277:341655. [PMID: 37604610 DOI: 10.1016/j.aca.2023.341655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 07/02/2023] [Accepted: 07/24/2023] [Indexed: 08/23/2023]
Abstract
Although various metabolomic methods have been reported in recent years, simultaneous detection of hydrophilic and hydrophobic metabolites in a single analysis remains a technical challenge. In this study, based on the combination of hydrophilic interaction liquid chromatography (HILIC) and reversed phase liquid chromatography (RPLC), an online two-dimensional liquid chromatography/triple quadrupole mass spectrometry method (2D-LC/TQMS) was developed for the simultaneous analysis of hydrophilic and hydrophobic metabolites of various biological samples. The method can measure 417 biologically important metabolites (e.g., amino acids and peptides, pyrimidines, purines, monosaccharides, fatty acids and conjugates, organic dicarboxylic acids, and others) with logP values ranging from -10.3 to 21.9. The metabolites are involved in a variety of metabolic pathways (e.g., purine metabolism, pyrimidine metabolism, tyrosine metabolism, galactose metabolism, gluconeogenesis, and TCA cycle). The developed method has good intra- and inter-day reproducibility (RSD of retention time <2%, RSD of peak area <30%), good linearity (R2 > 0.9) and wide linear range (from 0.0025 μg/mL to 5 μg/mL). The applicability of the method was tested using different biological samples (i.e., plasma, serum, urine, fecal, seminal plasma and liver) and it was found that 208 (out of 417) identical metabolites were detected in all biological samples. Furthermore, the metabolomic method was applied to a case/control study of urinary of bladder cancer. Thirty differential metabolites were identified that were involved in carbohydrate and amino acid metabolism.
Collapse
Affiliation(s)
- Rui Guo
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China
| | - Qisheng Zhong
- Guangzhou Analytical Center Analytical & Measuring Instruments Division, Shimadzu (China) Co., LTD, Guangzhou, 510656, China
| | - Jiaqi Liu
- Guangzhou Analytical Center Analytical & Measuring Instruments Division, Shimadzu (China) Co., LTD, Guangzhou, 510656, China
| | - Peiming Bai
- Zhongshan Hospital Affiliated of Xiamen University, Xiamen, 361004, China
| | - Zongpeng Wang
- Jinjiang Jingchun Technology Ltd., Quanzhou, 362200, China
| | - Jieling Kou
- ScienceLife (Xiamen) Technology Co., Ltd., Xiamen, 361000, China
| | - Peijie Chen
- Zhongshan Hospital Affiliated of Xiamen University, Xiamen, 361004, China.
| | - Jie Zhang
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiamen, 361102, China.
| | - Bo Zhang
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China.
| |
Collapse
|
8
|
Molenaar SRA, Bos TS, Boelrijk J, Dahlseid TA, Stoll DR, Pirok BWJ. Computer-driven optimization of complex gradients in comprehensive two-dimensional liquid chromatography. J Chromatogr A 2023; 1707:464306. [PMID: 37639847 DOI: 10.1016/j.chroma.2023.464306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 08/15/2023] [Accepted: 08/16/2023] [Indexed: 08/31/2023]
Abstract
Method development in comprehensive two-dimensional liquid chromatography (LC × LC) is a complicated endeavor. The dependency between the two dimensions and the possibility of incorporating complex gradient profiles, such as multi-segmented gradients or shifting gradients, renders method development by "trial-and-error" time-consuming and highly dependent on user experience. In this work, an open-source algorithm for the automated and interpretive method development of complex gradients in LC × LC-mass spectrometry (MS) was developed. A workflow was designed to operate within a closed-loop that allowed direct interaction between the LC × LC-MS system and a data-processing computer which ran in an unsupervised and automated fashion. Obtaining accurate retention models in LC × LC is difficult due to the challenges associated with the exact determination of retention times, curve fitting because of the use of gradient elution, and gradient deformation. Thus, retention models were compared in terms of repeatability of determination. Additionally, the design of shifting gradients in the second dimension and the prediction of peak widths were investigated. The algorithm was tested on separations of a tryptic digest of a monoclonal antibody using an objective function that included the sum of resolutions and analysis time as quality descriptors. The algorithm was able to improve the separation relative to a generic starting method using these complex gradient profiles after only four method-development iterations (i.e., sets of chromatographic conditions). Further iterations improved retention time and peak width predictions and thus the accuracy in the separations predicted by the algorithm.
Collapse
Affiliation(s)
- Stef R A Molenaar
- van 't Hoff Institute for Molecular Sciences, Analytical Chemistry Group, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands; Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | - Tijmen S Bos
- Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands; Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
| | - Jim Boelrijk
- Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands; AMLab, Informatics Institute, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands; AI4Science Lab, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Tina A Dahlseid
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, MN 56082, United States
| | - Dwight R Stoll
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, MN 56082, United States
| | - Bob W J Pirok
- van 't Hoff Institute for Molecular Sciences, Analytical Chemistry Group, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands; Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands.
| |
Collapse
|
9
|
Niezen LE, Bos TS, Schoenmakers PJ, Somsen GW, Pirok BWJ. Capacitively coupled contactless conductivity detection to account for system-induced gradient deformation in liquid chromatography. Anal Chim Acta 2023; 1271:341466. [PMID: 37328247 DOI: 10.1016/j.aca.2023.341466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/12/2023] [Accepted: 05/31/2023] [Indexed: 06/18/2023]
Abstract
The time required for method development in gradient-elution liquid chromatography (LC) may be reduced by using an empirical modelling approach to describe and predict analyte retention and peak width. However, prediction accuracy is impaired by system-induced gradient deformation, which can be especially prominent for steep gradients. As the deformation is unique to each LC instrument, it needs to be corrected for if retention modelling for optimization and method transfer is to become generally applicable. Such a correction requires knowledge of the actual gradient profile. The latter has been measured using capacitively coupled "contactless" conductivity detection (C4D), featuring a low detection volume (approximately 0.05 μL) and compatibility with very high pressures (80 MPa or more). Several different solvent gradients, from water to acetonitrile, water to methanol, and acetonitrile to tetrahydrofuran, could be measured directly without the addition of a tracer component to the mobile phase, exemplifying the universal nature of the approach. Gradient profiles were found to be unique for each solvent combination, flowrate, and gradient duration. The profiles could be described by convoluting the programmed gradient with a weighted sum of two distribution functions. Knowledge of the exact profiles was used to improve the inter-system transferability of retention models for toluene, anthracene, phenol, emodin, sudan-I and several polystyrene standards.
Collapse
Affiliation(s)
- Leon E Niezen
- Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands
| | - Tijmen S Bos
- Centre for Analytical Sciences Amsterdam (CASA), the Netherlands; Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, the Netherlands
| | - Peter J Schoenmakers
- Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands
| | - Govert W Somsen
- Centre for Analytical Sciences Amsterdam (CASA), the Netherlands; Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, the Netherlands
| | - Bob W J Pirok
- Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Faculty of Science, University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands.
| |
Collapse
|
10
|
Papatheocharidou C, Samanidou V. Two-Dimensional High-Performance Liquid Chromatography as a Powerful Tool for Bioanalysis: The Paradigm of Antibiotics. Molecules 2023; 28:5056. [PMID: 37446719 DOI: 10.3390/molecules28135056] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 06/25/2023] [Accepted: 06/26/2023] [Indexed: 07/15/2023] Open
Abstract
The technique of two-dimensional high-performance liquid chromatography has managed to gain the recognition it deserves thanks to the advantages of satisfactory separations it can offer compared to simple one-dimensional. This review presents in detail key features of the technique, modes of operation, and concepts that ensure its optimal application and consequently the best possible separation of even the most complex samples. Publications focusing on the separation of antibiotics and their respective impurities are also presented, providing information concerning the analytical characteristics of the technique related to the arrangement of the instrument and the chromatographic conditions.
Collapse
Affiliation(s)
- Christina Papatheocharidou
- Laboratory of Analytical Chemistry, School of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, School of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
| |
Collapse
|
11
|
Rahmani T, Ampe A, Lynen F. Temperature Responsive × Fast Chiral Comprehensive Liquid Chromatography: a New 2D-LC Platform for Resolving Mixtures of Chiral Isomers. Anal Chem 2023. [PMID: 37262425 DOI: 10.1021/acs.analchem.3c00780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Chiral resolution of solutes occurring in mixtures of unrelated species is of relevance in life sciences and in pharmaceutical analysis. While this is conceptually achievable by comprehensive two-dimensional liquid chromatography (LC × LC), few approaches exist whereby the second dimension comprises the chiral separation. The latter is preferable in combination with a conventional reversed phase type of separation in the first dimension as it offers an extension of a conventional achiral analysis. The implementation of such rapid chiral analyses in the second dimension was, thus far, limited by the challenging transfer of the first dimension mobile phase to the second dimension while still achieving chiral separation. In this study, the combination of temperature-responsive and reversed-phase chiral liquid chromatography is assessed in terms of enantioselective separation of a broad range of pharmaceutical compounds. Applying temperature-responsive liquid chromatography (TRLC) in the first dimension allows for analyses to be performed under purely aqueous conditions, which then allows for complete and more generic refocusing of (organic) solutes prior to the second dimension. This offers an enhanced ability to employ fast and broad compositional gradients over the chiral dimension, which broadens the applicability of the technique. In the proposed platform, seven chiral columns (superficially porous and fully porous columns (comprising both polysaccharide and macrocyclic antibiotic phases)) and four mobile phase gradients were screened on a pharmaceutical test mixture. The platform was shown to be able to offer the necessary resolving power for the molecules at hand and offers a new approach for chiral screening of mixtures of unrelated compounds.
Collapse
Affiliation(s)
- Turaj Rahmani
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Adriaan Ampe
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Frédéric Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| |
Collapse
|
12
|
Li F, Chen S, Studzińska S, Lämmerhofer M. Polybutylene terephthalate-based stationary phase for ion-pair-free reversed-phase liquid chromatography of small interfering RNA. Part 2: Use for selective comprehensive two-dimensional liquid chromatography. J Chromatogr A 2023; 1701:464069. [PMID: 37216850 DOI: 10.1016/j.chroma.2023.464069] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/06/2023] [Accepted: 05/13/2023] [Indexed: 05/24/2023]
Abstract
With the increasing numbers of nucleic acid-based pharmaceuticals like antisense oligonucleotides (ASO), small interfering ribonucleic acid (siRNA) entering the market, research facilities, pharmaceutical industries and also regulatory authorities have been looking for efficient analytical methods for these synthetic oligonucleotides (ON). Besides of conventional one-dimensional (1D) reversed-phase liquid chromatography with or without ion-pairing (IP-RP-LC, RP-LC), hydrophilic liquid chromatography (HILIC) and mixed-mode chromatography (MMC), two-dimensional (2D) approaches combining two orthogonal chromatographic techniques also become more relevant due to the high structural complexity of oligonucleotides. Recently, we tested a polybutylene terephthalate(PBT)-based stationary phase under ion-pairing free RP mode for the liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) analysis of siRNA (Patisiran). In this study, retention profile and chromatographic orthogonality, respectively, were compared to other LC-modes like HILIC, IP-RPLC, another ion-pair free cholesterol-bonded RPLC and MMC considering their normalized retention times. Finally, because of higher orthogonality, the ion-pairing free PBT-bonded RPLC as first dimension (1D) was hyphenated with HILIC in the second dimension (2D) in a selective comprehensive 2D-LC setup leading to an enhanced resolution for peak purity evaluation of the main ON entities.
Collapse
Affiliation(s)
- Feiyang Li
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| | - Shenkai Chen
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| | - Sylwia Studzińska
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany; Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Torun, 7 Gagarin Str., PL-87-100 Toruń, Poland
| | - Michael Lämmerhofer
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
| |
Collapse
|
13
|
Optimizing transfer and dilution processes when using active solvent modulation in on-line two-dimensional liquid chromatography. Anal Chim Acta 2023; 1252:341040. [PMID: 36935135 DOI: 10.1016/j.aca.2023.341040] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/06/2023]
Abstract
Two-dimensional liquid chromatography (2D-LC) is becoming increasingly popular for the analysis of complex samples, which is partly due to the recent introduction of commercial 2D-LC systems. To deal with the mobile phase incompatibility between highly orthogonal retention mechanisms, such as hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC), several strategies have been introduced over the years. One of these strategies is active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension before transfer to the second dimension. This strategy has gained a lot of attention and holds great potential, however, no clear guidelines are currently in place for its use. Therefore, this study aims to investigate how the ASM process can be optimized when using highly incompatible LC combinations, such as HILIC and RPLC, in a simplified selective comprehensive 2D-LC set-up (sHILIC x RPLC) to suggest guidelines for future users. Using a representative sample, the dilution factor (DF), the duration of the ASM phase, the filling percentage of the sample loops, and their unloading configuration are investigated and optimized. It is observed that a DF of 10 with an optimal ASM phase duration, a sample loop filling of maximum 25%, and an unloading configuration in backflush mode, result in the best peak shapes, intensities, and recoveries for early eluting compounds, while keeping the total analysis time minimal. Based on these results, some general recommendations are made that could also be applied in other 2D-LC modes, such as comprehensive 2D-LC (LC x LC), heart-cutting 2D-LC (LC-LC), and other chromatographic combinations with mobile phase incompatibility issues.
Collapse
|
14
|
Caño-Carrillo I, Gilbert-López B, Montero L, Martínez-Piernas AB, García-Reyes JF, Molina-Díaz A. Comprehensive and heart-cutting multidimensional liquid chromatography-mass spectrometry and its applications in food analysis. MASS SPECTROMETRY REVIEWS 2023. [PMID: 37056215 DOI: 10.1002/mas.21845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 03/07/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analyzed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimization of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality, and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.
Collapse
Affiliation(s)
- Irene Caño-Carrillo
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Lidia Montero
- Institute of Food Science Research-CIAL (CSIC-UAM), Madrid, Spain
| | - Ana B Martínez-Piernas
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Juan F García-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| |
Collapse
|
15
|
Caño-Carrillo I, Gilbert-López B, Montero L, Martínez-Piernas AB, García-Reyes JF, Molina-Díaz A. Comprehensive and heart-cutting multidimensional liquid chromatography-mass spectrometry and its applications in food analysis. MASS SPECTROMETRY REVIEWS 2023. [PMID: 37010157 DOI: 10.1002/mas.21843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 03/07/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analysed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimisation of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.
Collapse
Affiliation(s)
- Irene Caño-Carrillo
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Lidia Montero
- Institute of Food Science Research-CIAL (CSIC-UAM), Madrid, Spain
| | - Ana B Martínez-Piernas
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Juan F García-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
- University Research Institute for Olives Grove and Olive Oil, University of Jaén, Jaén, Spain
| |
Collapse
|
16
|
Chin S, Cruz K, Goyon A, Venkatramani CJ, Yehl PM, Kurita KL. Two-dimensional reversed phase-normal phase liquid chromatography for simultaneous achiral-chiral analysis to support high-throughput experimentation. J Chromatogr A 2023; 1692:463820. [PMID: 36796276 DOI: 10.1016/j.chroma.2023.463820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/20/2023] [Accepted: 01/20/2023] [Indexed: 02/05/2023]
Abstract
Typical chromatographic analysis of chiral compounds requires the use of achiral methods to evaluate impurities or related substances along with separate methods to evaluate chiral purity. The use of two-dimensional liquid chromatography (2D-LC) to support simultaneous achiral-chiral analysis has become increasingly advantageous in the field of high-throughput experimentation where low reaction yields or side reactions can lead to challenging direct chiral analysis. Advancements in multi-dimensional chromatography have led to the development of robust 2D-LC instrumentation with reversed phase solvent systems (RPLC-RPLC) enabling this simultaneous analysis, eliminating the need to purify crude reaction mixtures to determine stereoselectivity. However, when chiral RPLC cannot separate a chiral impurity from the desired product, there are few viable commercial options. The coupling of NPLC to RPLC (RPLC-NPLC) continues to remain elusive due to solvent immiscibility between the two solvent systems. This solvent incompatibility leads to lack of retention, band broadening, poor resolution, poor peak shapes, and baseline issues in the second dimension. A study was conducted to understand the effect of various water-containing injections on NPLC and applied to the development of robust RPLC-NPLC methods. Following thoughtful consideration and modifications to the design of a 2D-LC system in regards to mobile phase selection, sample loop sizing, targeted mixing, and solvent compatibility, proof of concept has been demonstrated with the development of reproducible RPLC-NPLC 2D-LC methods to perform simultaneous achiral-chiral analysis. Second dimension NPLC method performance proved comparable to corresponding 1D-NPLC methods with excellent percent difference in enantiomeric excess results ≤ 1.09% and adequate limits of quantitation down to 0.0025 mg/mL for injection volumes of 2 µL, or 5 ng on-column.
Collapse
Affiliation(s)
- Steven Chin
- Department of Small Molecule Analytical Chemistry, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, United States.
| | - Karissa Cruz
- Department of Small Molecule Analytical Chemistry, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, United States
| | - Alexandre Goyon
- Department of Small Molecule Analytical Chemistry, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, United States
| | - Cadapakam J Venkatramani
- Department of Small Molecule Analytical Chemistry, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, United States
| | - Peter M Yehl
- Department of Small Molecule Analytical Chemistry, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, United States
| | - Kenji L Kurita
- Department of Small Molecule Analytical Chemistry, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, United States.
| |
Collapse
|
17
|
Yang P, Gao W, Wasserman E. Identification and quantification of polymeric impurity in block copolymer by one-dimensional and two-dimensional liquid chromatography coupled to high-resolution mass spectrometry and evaporative light scattering detector. J Chromatogr A 2023; 1694:463909. [PMID: 36893507 DOI: 10.1016/j.chroma.2023.463909] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/07/2023]
Abstract
Identifying and quantifying polymeric impurities in a polymeric material is critical for understanding material quality and performance, but it remains a challenge requiring developing new characterization methods. In this work, a comprehensive two-dimensional liquid chromatography method with simultaneous evaporative light scattering and high-resolution mass spectrometry detection was developed to separate and identify a polymeric impurity in alkyl alcohol-initiated polyethylene oxide/polybutylene oxide diblock copolymer. Size exclusion chromatography was implemented in the first dimension, and gradient reversed-phase liquid chromatography using a large-pore C4 column was applied in the second dimension using an active solvent modulation valve as the interface to minimize the polymer breakthrough. The two-dimensional separation significantly reduced the complexity of the mass spectra data compared to the one-dimensional separation, and the combination of retention time and mass spectral interpretation led to the successful identification of the water-initiated triblock copolymer impurity. This identification was confirmed by comparison with the synthesized triblock copolymer reference material. A one-dimensional LC method with evaporative light scattering detection was employed to quantify the triblock impurity. The impurity level in three samples made with the different processes was determined to be in the range of 9-18 wt% using the triblock reference material as the standard.
Collapse
Affiliation(s)
- Peilin Yang
- The Dow Chemical Company, Analytical Science, 230 Abner Jackson Parkway, Lake Jackson, TX 77566, USA.
| | - Wei Gao
- The Dow Chemical Company, Analytical Science, Collegeville, PA 19426, USA
| | - Eric Wasserman
- The Dow Chemical Company, Home and Personal Care, Collegeville, PA 19426, USA
| |
Collapse
|
18
|
Zhang L, Shen L, Zhong Q, Zhou T. Diluting modulation-based two dimensional-liquid chromatography coupled with mass spectrometry for simultaneously determining multiclass prohibited substances in cosmetics. J Chromatogr A 2023; 1695:463954. [PMID: 37011524 DOI: 10.1016/j.chroma.2023.463954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 03/16/2023] [Accepted: 03/26/2023] [Indexed: 03/29/2023]
Abstract
Developing efficient and comprehensive screening methods for prohibited substances in cosmetics is critical for ensuring the quality and safety of cosmetics used in everyday life. This study proposed a heart-cutting two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method based on online diluting modulation for detecting multiclass prohibited substances in cosmetics. The 2D-LC-MS method combines HILIC and RPLC techniques. Compounds near the dead time that the first dimensional HILIC could not separate were transferred to the second dimensional RPLC by valve switch, achieving good separation with a wide range of polarities. Moreover, the online diluting modulation solved the problem of mobile phase incompatibility, realizing an excellent column-head focusing effect and reducing the loss of sensitivity. Besides, the first dimensional analysis did not restrict the flow rate of the second dimensional analysis owing to the diluting modulation. We demonstrated the 2D-LC-MS system by determining 126 prohibited substances in cosmetic products, including hormones, local anesthetics, anti-infectives, adrenergic agents, antihistamines, pesticides, and other chemicals. All correlation coefficients of the compounds were above 0.9950. The LODs and the LOQs ranged from 0.000259 ng/mL to 16.6 ng/mL and 0.000864 ng/mL to 55.3 ng/mL, respectively. The RSDs% for intra-day and inter-day precision were within 6% and 14%, respectively. Compared with conventional one-dimensional liquid chromatography methods, the established method expanded the analytical coverage of cosmetics-prohibited substances with reduced matrix effects for most compounds and improved sensitivity for polar analytes. The results indicated that the 2D-LC-MS method was a powerful tool for screening multiclass prohibited substances in cosmetics.
Collapse
Affiliation(s)
- Liping Zhang
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Lingling Shen
- Guangzhou Analytical Center, Analytical & Measuring Instruments Division, Shimadzu (China) Co., LTD, Guangzhou, 510010, China
| | - Qisheng Zhong
- Guangzhou Analytical Center, Analytical & Measuring Instruments Division, Shimadzu (China) Co., LTD, Guangzhou, 510010, China
| | - Ting Zhou
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, 510006, China.
| |
Collapse
|
19
|
Enhancing the compatibility of normal-phase chromatography x reversed-phase chromatography by combination of low-temperature sensitive aqueous-phase compatible normal- phase chromatography and at-column dilution modulation. J Chromatogr A 2023; 1691:463821. [PMID: 36724722 DOI: 10.1016/j.chroma.2023.463821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/19/2023] [Accepted: 01/21/2023] [Indexed: 01/27/2023]
Abstract
The nearly opposite retention mechanism in the two-dimensional liquid chromatography (2D-LC), which combines normal phase liquid chromatography (NPLC) and reversed phase liquid chromatography (RPLC), shows extremely high orthogonality and theoretical peak capacity. However, peak breakthrough and peak distortion caused by the highly incompatible 2D mobile phases counteracts the advantages offered by high orthogonality. To address this difficulty, this study proposes a comprehensive two-dimensional NPLC × RPLC integrating temperature-sensitive aqueous-phase compatible normal-phase chromatography (TSACNPLC) and at-column dilution modulation (ACDM). The proposed 2D-LC system uses an aqueous-miscible acetonitrile/methanol eluent in the 1st D NPLC, instead of an aqueous-phase immiscible eluent, such as n-hexane/methanol, to increase the miscibility with the RP mobile phase system. Additionally, the system exploits temperature-sensitive retention behavior to enhance the retention ability of aqueous-phase compatible NPLC. To verify the feasibility of the proposed 2D-LC, this study selected three multi-component samples with mid-to-low polarity, including ethoxylated (n ≈ 6) bisphenol A (BPA-6EO), ethoxylated (n ≈ 6) tristearylphenol (TSP-6EO), and safflower methanol extract. Next, the effectiveness of the constructed 2D-LC was systematically investigated, including low temperature-induced retention enhancement of NPLC, overcoming solvent incompatibility by ACDM, and optimization of 2 D separation conditions, was systematically investigated.
Collapse
|
20
|
Segmented two-dimensional liquid chromatography. Proof of concept study. J Chromatogr A 2023; 1691:463811. [PMID: 36731333 DOI: 10.1016/j.chroma.2023.463811] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/17/2023] [Accepted: 01/18/2023] [Indexed: 01/26/2023]
Abstract
The separation in liquid chromatography is defined either by the space domain where it proceeds until the least retained analyte reaches the outlet of the column or by the time when individual analytes elute out of the column. These two approaches lead to the four possible combinations of two-dimensional liquid chromatography with online space x time coupling being the least experimentally feasible. Here, we show the development of a novel two-dimensional liquid chromatography method combining separation defined by space and the conventional elution-based separation. First-dimension column consisted of four capillary segments coupled serially via two-position six-port valves allowing an online and comprehensive transfer of analytes from the first to the second dimension. After initial experiments using homemade monolithic capillary columns, we tested commercially available columns in both dimensions. We ended with the combination of packed capillary columns in the first dimension and monolithic capillary column in the second dimension. We used a reversed-phase retention mechanism in the first spatial dimension, while HILIC was in the second, time-based dimension. We also developed a theoretical model to describe the proposed two-dimensional separation that was further confirmed by utilizing both an isocratic and gradient elution in the second dimension. Finally, we applied our experimental setup to separate neurotransmitters contained in human urine.
Collapse
|
21
|
Packed modulation loops to reduce band broadening in two-dimensional liquid chromatography. J Chromatogr A 2023; 1690:463802. [PMID: 36681005 DOI: 10.1016/j.chroma.2023.463802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/12/2023] [Accepted: 01/13/2023] [Indexed: 01/15/2023]
Abstract
Modulation interfaces employing sample loops are applied in many hyphenated separations such as two-dimensional liquid chromatography (2D-LC). When the first-dimension effluent in 2D-LC is eluted from the modulation loop, dispersion effects occur due to differences in the laminar flow velocity of the filling and emptying flow. These effects were recently studied by Moussa et al. whom recommended the use of coiled loops to promote radial diffusion and reduce this effect. In the 1980s, Coq et al. investigated the use of packed loops, which also promote radial diffusion, in large volume injection 1D-LC. Unfortunately, this concept was never investigated in the context of 2D-LC modulation. Our work evaluates use of packed loops in 2D-LC modulation and compares them to unpacked coiled and uncoiled modulation loops. The effect of the solvents, loop volume, differences in filling and emptying rates, and loop elution direction on the elution profile was investigated. Statistical moments were used as a pragmatic tool to quantify elution profile characteristics. Decreased dispersion was observed in all cases for the packed loops compared to unpacked loops and unpacked coiled loops. In particular for larger loop volumes the dispersion was reduced significantly. Furthermore, countercurrent elution resulted in narrower elution profiles in all cases compared to concurrent elution. We found that packed modulation loops are of high interested when analytes are not refocussed in the second-dimension separation (e.g. for size-exclusion chromatography). Moreover, our work suggests that the use of packed loops may aid in prevention of loop overfilling.
Collapse
|
22
|
Cacciola F, Arena K, Dugo P, Mondello L. New Frontiers in Multidimensional Liquid Chromatography. LCGC EUROPE 2022. [DOI: 10.56530/lcgc.eu.zg3980s2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
In this extended special feature to celebrate the 35th anniversary edition of LCGC Europe, leading figures from the separation science community explore contemporary trends in separation science and identify possible future developments.
Collapse
|
23
|
Gu X, Yang L, Tao Q, Ai J, Yan C, Zheng J, Hong L. Application of heart-cutting two-dimensional liquid chromatography-mass spectrometry to the characterization of highly polar impurities in calcium gluconate injection. J Chromatogr A 2022; 1685:463632. [DOI: 10.1016/j.chroma.2022.463632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 10/28/2022] [Accepted: 10/30/2022] [Indexed: 11/06/2022]
|
24
|
Studzińska S, Li F, Szumski M, Buszewski B, Lämmerhofer M. Cholesterol Stationary Phase in the Separation and Identification of siRNA Impurities by Two-Dimensional Liquid Chromatography-Mass Spectrometry. Int J Mol Sci 2022; 23:ijms232314960. [PMID: 36499291 PMCID: PMC9738757 DOI: 10.3390/ijms232314960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 11/19/2022] [Accepted: 11/25/2022] [Indexed: 12/05/2022] Open
Abstract
The aim of this research was to develop a simple and efficient ion-pair reagent-free chromatographic method for the separation and qualitative determination of oligonucleotide impurities, exemplified by synthesis of raw products of the two single strands of patisiran siRNA. The stationary phases with mixed hydrophobic/hydrophilic properties (cholesterol and alkylamide) were firstly used for this purpose with reversed-phased high-performance liquid chromatography. Several different chromatographic parameters were tested for their impact on impurities separation: type, concentration, pH of salt, as well as organic solvent type in the mobile phase. The pH was the most influential factor on the separation and signal intensities in mass spectrometry detection. Finally, the optimized method included the application of cholesterol stationary phase, with mobile phase containing 20 mM ammonium formate (pH 6.5) and methanol. It allowed good separation and the identification of most impurities within 25 min. Since not all closely related impurities could be fully resolved from the main peak in this oligonucleotide impurity profiling, two-dimensional liquid chromatography was used for peak purity determination of the target oligonucleotides. The Ethylene Bridged Hybrid (BEH) Amide column in hydrophilic interaction liquid chromatography was applied in the second dimension, allowing additional separation of three closely related impurities.
Collapse
Affiliation(s)
- Sylwia Studzińska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., 87-100 Toruń, Poland
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
- Correspondence: ; Tel.: +48-56-6114753
| | - Feiyang Li
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| | - Michał Szumski
- Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, 4 Wilenska St., 87-100 Toruń, Poland
| | - Bogusław Buszewski
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., 87-100 Toruń, Poland
| | - Michael Lämmerhofer
- Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany
| |
Collapse
|
25
|
Wicht K, Baert M, Schipperges S, von Doehren N, Desmet G, Van Geem KM, de Villiers A, Lynen F. Enhanced Sensitivity in Comprehensive Liquid Chromatography: Overcoming the Dilution Problem in LC × LC via Temperature-Responsive Liquid Chromatography. Anal Chem 2022; 94:16728-16737. [DOI: 10.1021/acs.analchem.2c03300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard Street 8, D-76337 Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330 EA Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussel, Belgium
| | - Kevin M. Van Geem
- Laboratory for Chemical Technology (LCT), Department of Materials, Textiles and Chemical Engineering, Faculty of Engineering & Architecture, Ghent University, Technologiepark 125, B-9052 Zwijnaarde, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602 Matieland, South Africa
| | - Frédéric Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| |
Collapse
|
26
|
Tang S, Venkatramani CJ. Resolving Solvent Incompatibility in Two-Dimensional Liquid Chromatography with In-Line Mixing Modulation. Anal Chem 2022; 94:16142-16150. [DOI: 10.1021/acs.analchem.2c03572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Shijia Tang
- Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States
| | - Cadapakam J. Venkatramani
- Small Molecule Analytical Chemistry, Genentech, 1 DNA Way, South San Francisco, California 94080, United States
| |
Collapse
|
27
|
Renai L, Del Bubba M, Samanipour S, Stafford R, Gargano AF. Development of a comprehensive two-dimensional liquid chromatographic mass spectrometric method for the non-targeted identification of poly- and perfluoroalkyl substances in aqueous film-forming foams. Anal Chim Acta 2022; 1232:340485. [DOI: 10.1016/j.aca.2022.340485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 10/02/2022] [Accepted: 10/03/2022] [Indexed: 11/26/2022]
|
28
|
Bos TS, Boelrijk J, Molenaar SRA, van ’t Veer B, Niezen LE, van Herwerden D, Samanipour S, Stoll DR, Forré P, Ensing B, Somsen GW, Pirok BWJ. Chemometric Strategies for Fully Automated Interpretive Method Development in Liquid Chromatography. Anal Chem 2022; 94:16060-16068. [DOI: 10.1021/acs.analchem.2c03160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Tijmen S. Bos
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081HVAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Jim Boelrijk
- AMLab, Informatics Institute, University of Amsterdam, Science Park 904, 1098 XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
- AI4Science Lab, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Stef R. A. Molenaar
- Analytical Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Brian van ’t Veer
- Analytical Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Leon E. Niezen
- Analytical Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Denice van Herwerden
- Analytical Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Saer Samanipour
- Analytical Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Dwight R. Stoll
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, 56082Minnesota, United States
| | - Patrick Forré
- AMLab, Informatics Institute, University of Amsterdam, Science Park 904, 1098 XHAmsterdam, The Netherlands
- AI4Science Lab, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Bernd Ensing
- AI4Science Lab, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Computational Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Govert W. Somsen
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081HVAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
| | - Bob W. J. Pirok
- Analytical Chemistry Group, Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Science Park 904, 1098XHAmsterdam, The Netherlands
- AI4Science Lab, University of Amsterdam, Science Park 904, 1098XHAmsterdam, The Netherlands
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, 56082Minnesota, United States
| |
Collapse
|
29
|
Stoll DR. The Future of Method Development for Two-Dimensional Liquid Chromatography – Work Smarter, Not Just Harder? LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.iy5385p1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
Abstract
The potential for wider use of two-dimensional liquid chromatography (2D-LC) is becoming more evident as the complexity of samples that must be handled continues to increase in application areas ranging from biopharmaceuticals to biosourced consumer products. Although the sophistication and ease of use have improved in recent years for commercial 2D-LC instruments, many analysts are still intimidated by the method development process for 2D methods because of the larger number of variables involved compared to conventional liquid chromatography. In this article, I share my perspective on the trends in this area, and the developments we are likely to see in the field in the near future.
Collapse
|
30
|
den Uijl MJ, Roeland T, Bos TS, Schoenmakers PJ, van Bommel MR, Pirok BW. Assessing the feasibility of stationary-phase-assisted modulation for two-dimensional liquid-chromatography separations. J Chromatogr A 2022; 1679:463388. [DOI: 10.1016/j.chroma.2022.463388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/18/2022] [Accepted: 07/21/2022] [Indexed: 02/06/2023]
|
31
|
Buckenmaier S, Petersson P. Dealing with Wandering First-Dimension Peaks in 2D-LC Separations. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.me6285m3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The retention of large molecules, such as peptides and proteins, is strongly dependent on mobile-phase composition and temperature. Consequently, the retention times (tR) of these molecules often fluctuate from one separation to the next. In two-dimensional liquid chromatography (2D-LC), this fluctuation can be challenging to deal with, especially if only one or a few specific peaks in the first dimension (1D) separation are targeted for further separation. In this installment, we describe instrumental concepts that are useful for coping with this challenge.
Collapse
|
32
|
Verscheure L, Vanhoenacker G, Schneider S, Merchiers T, Storms J, Sandra P, Lynen F, Sandra K. 3D-LC-MS with 2D Multimethod Option for Fully Automated Assessment of Multiple Attributes of Monoclonal Antibodies Directly from Cell Culture Supernatants. Anal Chem 2022; 94:6502-6511. [PMID: 35442636 DOI: 10.1021/acs.analchem.1c05461] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Fully automated analysis of multiple structural attributes of monoclonal antibodies (mAbs) using three-dimensional liquid chromatography-mass spectrometry (3D-LC-MS) is described. The analyzer combines Protein A affinity chromatography in the first dimension (1D) with a multimethod option in the second dimension (2D) (choice between size exclusion (SEC), cation exchange (CEX), and hydrophobic interaction chromatography (HIC)) and desalting SEC-MS in the third dimension (3D). This innovative 3D-LC-MS setup allows simultaneous and sequential assessment of mAb titer, size/charge/hydrophobic variants, molecular weight (MW), amino acid (AA) sequence, and post-translational modifications (PTMs) directly from cell culture supernatants. The reported methodology that finds multiple uses throughout the biopharmaceutical development trajectory was successfully challenged by the analysis of different trastuzumab and tocilizumab samples originating from biosimilar development programs.
Collapse
Affiliation(s)
- Liesa Verscheure
- RIC Group, President Kennedypark 26, B-8500 Kortrijk, Belgium.,Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | | | - Sonja Schneider
- Agilent Technologies, Hewlett-Packard Strasse 8, D-76337 Waldbronn, Germany
| | - Tom Merchiers
- RIC Group, President Kennedypark 26, B-8500 Kortrijk, Belgium
| | - Julie Storms
- RIC Group, President Kennedypark 26, B-8500 Kortrijk, Belgium
| | - Pat Sandra
- RIC Group, President Kennedypark 26, B-8500 Kortrijk, Belgium.,Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Koen Sandra
- RIC Group, President Kennedypark 26, B-8500 Kortrijk, Belgium.,Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| |
Collapse
|
33
|
Kohler I, Verhoeven M, Haselberg R, Gargano AF. Hydrophilic interaction chromatography – mass spectrometry for metabolomics and proteomics: state-of-the-art and current trends. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106986] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
34
|
van den Hurk RS, Abdulhussain N, van Beurden AS, Dekker ME, Hulsbergen A, Peters RA, Pirok BW, van Asten AC. Characterization and comparison of smokeless powders by on-line two-dimensional liquid chromatography. J Chromatogr A 2022; 1672:463072. [DOI: 10.1016/j.chroma.2022.463072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/13/2022] [Accepted: 04/14/2022] [Indexed: 10/18/2022]
|
35
|
Yang P, Gao W, Pursch M, Luong J. Gaining New Insights in Advanced Polymeric Materials Using Comprehensive Two-Dimensional Liquid Chromatography. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.xh1183h9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Two-dimensional liquid chromatography (2D-LC) offers new insights into modern polymeric materials such as biodegradable polymers, polymers made from renewable feedstock, and complex formulated systems. Advances in instrumentation and the development of new modulation techniques enable more combinations of different separation modes. Hyphenation with universal and information-rich detectors further enhances the versatility and flexibility of the analytical strategy. Detailed characterization of copolymer composition heterogeneity and identification of polymeric ingredients in complex consumer products are key highlights of new applications.
Collapse
|
36
|
Stoll DR, Pirok BW. Perspectives on the Use of Retention Modeling to Streamline 2D-LC Method Development: Current State and Future Prospects. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.zo2782l9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The history of multidimensional liquid chromatography (MDLC) has been dominated by methods that have been developed using highly empirical, experience-driven, trial-and-error approaches. These approaches have been sufficient in progressing the field forward scientifically, primarily in academic research laboratories. However, more widespread usage of multidimensional separations will require more systematic approaches to method development that rely less on user experience and lower the barriers to development and use of methods by a wider community of users. In this mini-review, we discuss recent research aimed at developing such systematic, model-driven approaches to streamline method development and speculate about likely advances in the same direction in the near future. It seems likely that such model-driven approaches would be particularly helpful for methods developed for analyzing biopharmaceutical molecules, which tend to be very sensitive to slight changes in method conditions (for example, mobile phase composition).
Collapse
|
37
|
Haidar Ahmad IA, Kiffer A, Barrientos RC, Losacco GL, Singh A, Shchurik V, Wang H, Mangion I, Regalado EL. In Silico Method Development of Achiral and Chiral Tandem Column Reversed-phase Liquid Chromatography for Multicomponent Pharmaceutical Mixtures. Anal Chem 2022; 94:4065-4071. [PMID: 35199987 DOI: 10.1021/acs.analchem.1c05551] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Tandem column liquid chromatography (LC) is a convenient, cost-effective approach to resolve multicomponent mixtures by serially coupling columns on readily available one-dimensional separation systems without specialized user training. Yet, adoption of this technique remains limited, mainly due to the difficulty in identifying optimal selectivity out of many possible tandem column combinations. At this point, method development and optimization require laborious "hit-or-miss" experimentation and "blind" screening when investigating different column selectivity without standard analytes. As a result, many chromatography practitioners end up combining two columns of similar selectivity, limiting the scope and potential of tandem column LC as a mainstay for industrial applications. To circumvent this challenge, we herein introduce a straightforward in silico multifactorial approach as a framework to expediently map the separation landscape across multiple tandem columns (achiral and chiral) and eluent combinations (isocratic and gradient elution) under reversed-phase LC conditions. Retention models were built using commercially available LC simulator software showcasing less than 2% difference between experimental and simulated retention times for analytes of interest in multicomponent pharmaceutical mixtures (e.g., metabolites and cyclic peptides).
Collapse
Affiliation(s)
- Imad A Haidar Ahmad
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Alaina Kiffer
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Rodell C Barrientos
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Gioacchino Luca Losacco
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Andrew Singh
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Vladimir Shchurik
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Heather Wang
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Ian Mangion
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Erik L Regalado
- Analytical Research and Development, MRL, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| |
Collapse
|
38
|
Zagst H, Elgert C, Behrends S, Wätzig H. Combination of strong anion exchange liquid chromatography with microchip capillary electrophoresis sodium dodecyl sulfate for rapid two-dimensional separations of complex protein mixtures. Anal Bioanal Chem 2022; 414:1699-1712. [PMID: 34870722 PMCID: PMC8761713 DOI: 10.1007/s00216-021-03797-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 10/13/2021] [Accepted: 11/19/2021] [Indexed: 11/03/2022]
Abstract
Two-dimensional separations provide a simple way to increase the resolution and peak capacity of complex protein separations. The feasibility of a recently developed instrumental approach for two-dimensional separations of proteins was evaluated. The approach is based on the general principle of two-dimensional gel electrophoresis. In the first dimension, semi-preparative strong anion exchange high-performance liquid chromatography is utilized and fractions are collected by means of a fraction collector. They are subsequently analyzed in the second dimension with microchip capillary electrophoresis sodium dodecyl sulfate. Microchip capillary electrophoresis provides the necessary speed (approximately 1 min/fraction) for short analysis. In this study, three different samples were investigated. Different constructs of soluble guanylyl cyclase were expressed in Sf9-cells using the baculovirus expression system. Cell lysates were analyzed and the resulting separations were compared. In our experimental setup, the soluble guanylyl cyclase was identified among hundreds of other proteins in these cell lysates, indicating its potential for screening, process control, or analysis. The results were validated by immunoblotting. Samples from Chinese hamster ovary cell culture before and after a purification step were investigated and approximately 9% less impurities could be observed. The separation patterns obtained for human plasma are closely similar to patterns obtained with two-dimensional gel electrophoresis and a total of 218 peaks could be observed. Overall, the approach was well applicable to all samples and, based on these results, further directions for improvements were identified. .
Collapse
Affiliation(s)
- Holger Zagst
- Technische Universität Braunschweig, Institute of Medicinal and Pharmaceutical Chemistry, Beethovenstraße 55, 38106, Braunschweig, Germany
| | - Christin Elgert
- Technische Universität Braunschweig, Institute of Pharmacology, Toxicology and Clinical Pharmacy, Mendelssohnstraße 1, 38106, Braunschweig, Germany
| | - Sönke Behrends
- Technische Universität Braunschweig, Institute of Pharmacology, Toxicology and Clinical Pharmacy, Mendelssohnstraße 1, 38106, Braunschweig, Germany
| | - Hermann Wätzig
- Technische Universität Braunschweig, Institute of Medicinal and Pharmaceutical Chemistry, Beethovenstraße 55, 38106, Braunschweig, Germany.
| |
Collapse
|
39
|
Groeneveld G, Dunkle MN, Pursch M, Mes EP, Schoenmakers PJ, Gargano AF. Investigation of the Effects of Solvent-Mismatch and Immiscibility in Normal-Phase × Aqueous Reversed-Phase Liquid Chromatography. J Chromatogr A 2022; 1665:462818. [DOI: 10.1016/j.chroma.2022.462818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/28/2021] [Accepted: 01/07/2022] [Indexed: 11/28/2022]
|
40
|
Wicht K, Baert M, Muller M, Bandini E, Schipperges S, von Doehren N, Desmet G, de Villiers A, Lynen F. Comprehensive two-dimensional temperature-responsive × reversed phase liquid chromatography for the analysis of wine phenolics. Talanta 2022; 236:122889. [PMID: 34635268 DOI: 10.1016/j.talanta.2021.122889] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 11/18/2022]
Abstract
Phenolic compounds are an interesting class of natural products because of their proposed contribution to health benefits of foods and beverages and as a bio-source of organic (aromatic) building blocks. Phenolic extracts from natural products are often highly complex and contain compounds covering a broad range in molecular properties. While many 1D-LC and mass spectrometric approaches have been proposed for the analysis of phenolics, this complexity inevitably leads to challenging identification and purification. New insights into the composition of phenolic extracts can be obtained through online comprehensive two-dimensional liquid chromatography (LC × LC) coupled to photodiode array and mass spectrometric detection. However, several practical hurdles must be overcome to achieve high peak capacities and to obtain robust methods with this technique. In many LC × LC configurations, refocusing of analytes at the head of the 2D column is hindered by the high eluotropic strength of the solvent transferred from the 1D to the 2D, leading to peak breakthrough or broadening. LC × LC combinations whereby a purely aqueous mobile phase is used in the 1D and RPLC is used in the 2D are unaffected by these phenomena, leading to more robust methods. In this contribution, the combination of temperature-responsive liquid chromatography (TRLC) with RPLC is used for the first time for the analysis of phenolic extracts of natural origin to illustrate the potential of this alternative combination for natural product analyses. The possibilities of the combination are investigated through analysis of wine extracts by TRLC × RPLC-DAD and TRLC × RPLC-ESI-MS.
Collapse
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Magriet Muller
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Elena Bandini
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard St 8, D-76337, Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330, EA, Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050, Brussel, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium.
| |
Collapse
|
41
|
Sun M, Schoenmakers P. A compound post-column re-focusing approach in supercritical fluid chromatography. J Chromatogr A 2021; 1660:462642. [PMID: 34808522 DOI: 10.1016/j.chroma.2021.462642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/19/2021] [Accepted: 10/20/2021] [Indexed: 10/19/2022]
Abstract
Supercritical-fluid chromatography (SFC) is regaining popularity in various fields of analytical chemistry owning to significant advances in instrumentation made in the past decade. However, due to the CO2 based mobile phase and the high flow rates often employed, detection of trace amounts of analytes and coupling with certain detectors or other chromatography techniques are still difficult under many circumstances. In this study we propose a post-column re-focusing approach for SFC analysis to achieve not only signal enhancement in UV-Vis detection, but also actual concentration enhancement of the analyte. By heart-cutting and transporting a selected fraction from the SFC flow into a trapping column with a flushing solvent, re-focusing of the collected analytes can be achieved by re-mobilization with another solvent once the depressurized CO2 is eliminated. By carefully selecting the trapping stationary phase and the two solvents, signal-enhancement ratios between 2.2 and 6.4 were realized for four representative compounds eluting with very different percentages of SFC modifier (methanol). The actual concentration enhancement was lower (ratios between 1.7 to 2.9), because the UV response of the analytes was found to differ significantly under SFC and LC conditions.
Collapse
Affiliation(s)
- Mingzhe Sun
- Analytical Chemistry Group, Van't Hoff Institute for Molecular Sciences, University of Amsterdam, 1098 XH Amsterdam, The Netherlands; Centre for Analytical Sciences Amsterdam (CASA), The Netherlands.
| | - Peter Schoenmakers
- Analytical Chemistry Group, Van't Hoff Institute for Molecular Sciences, University of Amsterdam, 1098 XH Amsterdam, The Netherlands; Centre for Analytical Sciences Amsterdam (CASA), The Netherlands.
| |
Collapse
|
42
|
Beschnitt A, Schwikowski M, Hoffmann T. Towards comprehensive non-target screening using heart-cut two-dimensional liquid chromatography for the analysis of organic atmospheric tracers in ice cores. J Chromatogr A 2021; 1661:462706. [PMID: 34864235 DOI: 10.1016/j.chroma.2021.462706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 11/29/2022]
Abstract
Non-target screening of secondary organic aerosol compounds in ice cores is used to reconstruct atmospheric conditions and sources and is a valuable tool to elucidate the chemical profiles of samples with the aim to obtain as much information as possible from one mass spectrometric measurement. The coupling of mass spectrometry to chromatography limits the results of a non-target screening to signals of compounds within a certain polarity range based on the utilized stationary phases of the columns. Comprehensive two-dimensional liquid chromatography (LCxLC) introduces a second column of different functionality to enable the analysis of a broader range of analytes. Conventional LCxLC requires complex instrumental setups and is difficult to implement for most laboratories. In this work we demonstrate an approach to approximate a comprehensive non-target screening using a simple instrumental setup employing two columns of orthogonal functionalities (HILIC and reversed-phase), an additional pump, and an additional six-port valve. The void volume of the first dimension is transferred to the reversed-phase column to analyze low-polarity compounds during the re-equilibration of the HILIC. Method validation showed adequate repeatability and detection limits for two selected void volume markers and application to snow samples collected at the high-alpine research station Jungfraujoch yielded a total of 270 signals. Comparison to the one-dimensional HILIC approach revealed 175 signals exclusively detected in the two-dimensional method, of which 23 were detected in the second dimension. Detailed analysis of the chemical composition showed consistency with expected compounds in snow samples like lignin or cellulose combustion products from biomass burning or secondary organic aerosol constituents. The results confirmed that one-dimensional chromatography was not sufficient to cover the entire range of compounds and the developed two-dimensional approach will improve the information content from non-target screening while maintaining time of analysis and a simple instrumental setup.
Collapse
Affiliation(s)
- Anja Beschnitt
- Department of Chemistry, Johannes-Gutenberg University, Duesbergweg 10-14, Mainz 55128, Germany
| | - Margit Schwikowski
- Paul Scherrer Institute, Forschungsstrasse 111, Villigen PSI 5232, Switzerland
| | - Thorsten Hoffmann
- Department of Chemistry, Johannes-Gutenberg University, Duesbergweg 10-14, Mainz 55128, Germany.
| |
Collapse
|
43
|
Pánczél J, Schudok M, Schiell M, Riedel J, Kertesz V. An Effective QWBA/UHPLC-MS/Tissue Punch Approach: Solving a Pharmacokinetic Issue via Quantitative Met-ID. Drug Metab Lett 2021; 14:152-162. [PMID: 34818998 DOI: 10.2174/1872312814666210813114700] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 07/05/2021] [Accepted: 07/06/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND Methods to provide absolute quantitation of the administered drug and corresponding metabolites in tissue in a spatially resolved manner is a challenging but much needed capability in pharmaceutical research. Quantitative Whole-Body Autoradiography (QWBA) after a single- dose intravenous (3 mg/kg) and extravascular (30 mg/kg) administrations of an in vitro metabolically stable test compound (structure not reported here) indicated quick tissue distribution and excretion. OBJECTIVE Good bioavailability and short in vivo half-lives were determined formerly for the same test compound. For closing gaps in the understanding of pharmacokinetic data and in vitro results, radioactive hot spots on whole-body tissue sections had been profiled. METHODS Punches from selected tissue regions containing high radioactivity in the tissue sections previously analyzed by QWBA were extracted by a highly organic solvent and analyzed without any consecutive sample preparation step, applying Ultra High Performance Liquid Chromatography- Mass Spectrometry (UHPLC-MS) and off-line radioanalysis to maximize signal levels for metabolite identification and profiling. RESULTS The analysis revealed that the test compound was metabolized intensively by phase I reactions in vivo and the metabolites formed were excreted in bile and urine. The predominant metabolites showed abundant signal intensities both by MS and by radioanalysis but the MS signal intensities generally underestimated the real abundances of metabolites relative to the unchanged drug. CONCLUSION This work illustrates that maximizing the sensitivity of tissue punch radioanalysis and the combination with UHPLC-MS leads to a better insight into pharmacokinetic processes by providing quantitative data with high molecular selectivity.
Collapse
Affiliation(s)
- József Pánczél
- Research and Development, DMPK, Sanofi-Aventis Deutschland GmbH, Frankfurt, Germany
| | - Manfred Schudok
- Research and Development, DMPK, Sanofi-Aventis Deutschland GmbH, Frankfurt, Germany
| | - Matthias Schiell
- Research and Development, DMPK, Sanofi-Aventis Deutschland GmbH, Frankfurt, Germany
| | - Jens Riedel
- Research and Development, DMPK, Sanofi-Aventis Deutschland GmbH, Frankfurt, Germany
| | - Vilmos Kertesz
- Bioanalytical Mass Spectrometry Group, Biological Sciences Division, Oak Ridge National Laboratory, Oak Ridge TN 37831, United States
| |
Collapse
|
44
|
Byrdwell WC, Kotapati HK, Goldschmidt R, Jakubec P, Nováková L. Three-dimensional liquid chromatography with parallel second dimensions and quadruple parallel mass spectrometry for adult/infant formula analysis. J Chromatogr A 2021; 1661:462682. [PMID: 34863062 DOI: 10.1016/j.chroma.2021.462682] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/05/2021] [Accepted: 11/09/2021] [Indexed: 12/11/2022]
Abstract
Three dimensions of chromatographic separation, using split-flow two-dimensional liquid chromatography (SF-2D-LC) with two parallel second dimensions, LC × 2LC, combined with quadruple parallel mass spectrometry (LC3MS4) is demonstrated for analysis of NIST SRM 1849a adult/infant formula. The first dimension, 1D, was a conventional non-aqueous reversed-phase (NARP) HPLC separation using two C18 columns in series, followed by detection using an ultraviolet (UV) detector, a fluorescence detector (FLD), with flow then split to a corona charged aerosol detector (CAD), and then dual parallel mass spectrometry (MS), conducted in atmospheric pressure photoionization (APPI) and electrospray ionization (ESI) modes. The first second dimension, 2D(1), UHPLC was conducted on a 50.0 mm C30 column using a NARP-UHPLC parallel gradient for separation of short-chain triacylglycerols (TAGs) from long-chain TAGs, with detection by UV and ESI-MS. The second dimension, 2D(2), UHPLC was conducted using a 100.0 mm C30 column with a NARP-UHPLC parallel gradient for improved separation of TAG isomers, with detection by UV, an evaporative light scattering detector, and high-resolution, accurate-mass (HRAM) ESI-MS. Transferred eluent dilution was used to refocus peaks and keep them sharp during elution in both 2Ds. The separation space in the 2D(2) was optimized using multi-cycle (aka, "constructive wraparound") elution, which employed flow rate programming. In the 1D, calibration lines for quantification of fat-soluble vitamins were constructed. A lipidomics approach to TAG identification and quantification by HRAM-ESI-MS was applied to the 2D(2). These experiments can be represented: LC1MS2 × (LC1MS1 + LC1MS1) = LC3MS4, or three-dimensional liquid chromatography with quadruple parallel mass spectrometry.
Collapse
Affiliation(s)
- William Craig Byrdwell
- Methods and Application of Food Composition Lab, Agricultural Research Service, U.S. Dept. of Agriculture, 10300 Baltimore Ave., Beltsville, MD, 20705, USA.
| | - Hari K Kotapati
- Methods and Application of Food Composition Lab, Agricultural Research Service, U.S. Dept. of Agriculture, 10300 Baltimore Ave., Beltsville, MD, 20705, USA
| | - Robert Goldschmidt
- Methods and Application of Food Composition Lab, Agricultural Research Service, U.S. Dept. of Agriculture, 10300 Baltimore Ave., Beltsville, MD, 20705, USA
| | - Pavel Jakubec
- Charles University, Faculty of Pharmacy, Dept. of Analytical Chemistry, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| | - Lucie Nováková
- Charles University, Faculty of Pharmacy, Dept. of Analytical Chemistry, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| |
Collapse
|
45
|
Feng J, Zhong Q, Kuang J, Liu J, Huang T, Zhou T. Simultaneous Analysis of the Metabolome and Lipidome Using Polarity Partition Two-Dimensional Liquid Chromatography-Mass Spectrometry. Anal Chem 2021; 93:15192-15199. [PMID: 34739231 DOI: 10.1021/acs.analchem.1c03905] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Comprehensive metabolic profiling is a considerable challenge for systems biology since the metabolites in biological samples have significant polarity differences. A heart-cutting two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method-based polarity partition was established to analyze both the metabolome and lipidome in a single run. Based on the polarity partition strategy, metabolites with high polarity were retained and separated by one-dimensional hydrophilic chromatography, while low- and medium-polarity lipids were collected into a sample loop and injected into two-dimensional reversed-phase chromatography for separation. A simple online dilution strategy realized the online coupling of the 2D-LC-MS, which effectively solved band broadening and peak distortion caused by solvent incompatibility. Moreover, a dual gradient elution procedure was introduced to further broaden the coverage of low-polarity lipids. The metabolites' log P values, which this 2D-LC-MS method could analyze, ranged from -8.79 to 26.86. The feasibility of the 2D-LC-MS system was demonstrated by simultaneous analysis of the metabolome and lipidome in rat plasma related to depression. A total of 319 metabolites were determined within 40 min, including organic acids, nucleosides, carbohydrate derivatives, amino acids, lipids, and other organic compounds. Finally, 44 depression-related differential metabolites were screened. Compared with conventional LC-MS-based methods, the 2D-LC method covered over 99% of features obtained by two conventional methods. In addition, the selectivity and resolution of the hydrophilic metabolites were improved, and the matrix effects of the hydrophobic metabolites were reduced in the developed method. The results indicated that the established 2D-LC system is a powerful tool for comprehensive metabolomics studies.
Collapse
Affiliation(s)
- Jieqing Feng
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou 510006, China
| | - Qisheng Zhong
- Guangzhou Analytical Applications Center, Shimadzu (China) Co., LTD, Guangzhou 510010, China
| | - Jiangmeng Kuang
- Guangzhou Analytical Applications Center, Shimadzu (China) Co., LTD, Guangzhou 510010, China
| | - Jiaqi Liu
- Guangzhou Analytical Applications Center, Shimadzu (China) Co., LTD, Guangzhou 510010, China
| | - Taohong Huang
- Shanghai Analytical Applications Center, Shimadzu (China) Co., LTD, Shanghai 200233, China
| | - Ting Zhou
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou 510006, China
| |
Collapse
|
46
|
Burlet-Parendel M, Faure K. Opportunities and challenges of liquid chromatography coupled to supercritical fluid chromatography. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116422] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
47
|
Li H, Liu C, Zhao L, Xu D, Zhang T, Wang Q, Cabooter D, Jiang Z. A systematic investigation of the effect of sample solvent on peak shape in nano- and microflow hydrophilic interaction liquid chromatography columns. J Chromatogr A 2021; 1655:462498. [PMID: 34496327 DOI: 10.1016/j.chroma.2021.462498] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/20/2021] [Accepted: 08/22/2021] [Indexed: 01/03/2023]
Abstract
A frequently encountered problem in the practical application of nano- and microflow hydrophilic interaction chromatography (HILIC) columns is the distortion of peak shapes arising from a mismatch between the sample solvent and the mobile phase. An unmatched or improperly matched sample solvent can distort the peak shape of analytes and influence their retention times, thereby affecting the quality of the resulting chromatogram. In this work, the effect of sample solvent composition (mixtures of acetonitrile, water, methanol and isopropanol in different ratios) and injection volume (20-100 nL) was systematically investigated using a selection of neutral and charged compounds on a series of zwitterionic and charged small I.D. (0.1-0.3 mm) HILIC columns. For retained compounds, pure ACN was demonstrated to be the best sample solvent to obtain narrow peaks, while for compounds that eluted very close to the solvent peak, the peak shape was distorted when the sample solvent consisted of pure ACN. A highly aqueous sample solvent, which interferes with the partitioning of polar analytes into the stationary phase, was demonstrated to be detrimental for the peak shape of retained neutral compounds, while for unretained compounds that do not or hardly interact with the stationary phase, a high amount of water in the sample solvent was not problematic. For charged compounds, water in the sample solvent favored the electrostatic attraction with the stationary phase. Therefore, the retention time of charged analytes was shown to increase with increasing water content in the sample solvent. Even when a large amount of water was present in the sample solvent, the peak shapes of these compounds were still acceptable. For highly polar compounds with a limited solubility in aqueous sample solvents, it was found that a mixture of ACN and MeOH or IPA is a good alternative.
Collapse
Affiliation(s)
- Haibin Li
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China; International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China; Department for Pharmaceutical and Pharmacological Sciences, KU Leuven, Pharmaceutical Analysis, Herestraat 49, Leuven 3000, Belgium
| | - Chusheng Liu
- NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shenzhen Institute for Drug Control, Shenzhen 518057, China
| | - Li Zhao
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China; International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China
| | - Dongsheng Xu
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China; International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China
| | - Tingting Zhang
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China; International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China
| | - Qiqin Wang
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China; International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China
| | - Deirdre Cabooter
- Department for Pharmaceutical and Pharmacological Sciences, KU Leuven, Pharmaceutical Analysis, Herestraat 49, Leuven 3000, Belgium.
| | - Zhengjin Jiang
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China; International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China.
| |
Collapse
|
48
|
Furlani IL, da Cruz Nunes E, Canuto GAB, Macedo AN, Oliveira RV. Liquid Chromatography-Mass Spectrometry for Clinical Metabolomics: An Overview. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1336:179-213. [PMID: 34628633 DOI: 10.1007/978-3-030-77252-9_10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
Abstract
Metabolomics is a discipline that offers a comprehensive analysis of metabolites in biological samples. In the last decades, the notable evolution in liquid chromatography and mass spectrometry technologies has driven an exponential progress in LC-MS-based metabolomics. Targeted and untargeted metabolomics strategies are important tools in health and medical science, especially in the study of disease-related biomarkers, drug discovery and development, toxicology, diet, physical exercise, and precision medicine. Clinical and biological problems can now be understood in terms of metabolic phenotyping. This overview highlights the current approaches to LC-MS-based metabolomics analysis and its applications in the clinical research.
Collapse
Affiliation(s)
- Izadora L Furlani
- Núcleo de Pesquisa em Cromatografia (Separare), Department of Chemistry, Federal University of São Carlos, São Carlos, SP, Brazil
| | - Estéfane da Cruz Nunes
- Department of Analytical Chemistry, Institute of Chemistry, Federal University of Bahia, Salvador, BA, Brazil
| | - Gisele A B Canuto
- Department of Analytical Chemistry, Institute of Chemistry, Federal University of Bahia, Salvador, BA, Brazil
| | - Adriana N Macedo
- Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Regina V Oliveira
- Núcleo de Pesquisa em Cromatografia (Separare), Department of Chemistry, Federal University of São Carlos, São Carlos, SP, Brazil.
| |
Collapse
|
49
|
Chapel S, Heinisch S. Strategies to circumvent the solvent strength mismatch problem in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2021; 45:7-26. [PMID: 34525266 DOI: 10.1002/jssc.202100534] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/23/2021] [Accepted: 08/24/2021] [Indexed: 11/09/2022]
Abstract
On-line comprehensive two-dimensional liquid chromatography is a powerful technique for the separation of highly complex samples. Due to the addition of the second dimension of separation, impressive peak capacities can be obtained within a reasonable analysis time compared to one-dimensional liquid chromatography. In online comprehensive two-dimensional liquid chromatography, the separation power is maximized by selecting two separation dimensions as orthogonal as possible, which most often requires the combination of different mobile phases and stationary phases. The online transfer of a given solvent from the first dimension to the second dimension may cause severe injection effects in the second dimension, mostly due to solvent strength mismatch. Those injection effects may include peak broadening, peak distortion, peak splitting or breakthrough phenomenon. They are often found to reduce significantly the peak capacity and the peak intensity. To overcome such effects, arising specifically in online comprehensive two-dimensional liquid chromatography, different methods have been developed over the years. In this review, we focused on the most recently reported ones. A critical discussion, supported by a theoretical approach, gives an overview of their advantages and drawbacks.
Collapse
Affiliation(s)
- Soraya Chapel
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| | - Sabine Heinisch
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| |
Collapse
|
50
|
McIlvin MR, Saito MA. Online Nanoflow Two-Dimension Comprehensive Active Modulation Reversed Phase-Reversed Phase Liquid Chromatography High-Resolution Mass Spectrometry for Metaproteomics of Environmental and Microbiome Samples. J Proteome Res 2021; 20:4589-4597. [PMID: 34384028 DOI: 10.1021/acs.jproteome.1c00588] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Metaproteomics is a powerful analytical approach that can assess the functional capabilities deployed by microbial communities in both environmental and biomedical microbiome settings. Yet, the mass spectra resulting from these mixed biological communities are challenging to obtain due to the high number of low intensity peak features. The use of multiple dimensions of chromatographic separation prior to mass spectrometry analyses has been applied to proteomics previously but can require increased sampling handling and instrument time. Here, we demonstrate an automated online comprehensive active modulation two-dimensional liquid chromatography method for metaproteome sample analysis. A high pH PLRP-S column was used in the first dimension followed by low pH separation in the second dimension using dual modulating C18 traps and a C18 column. This method increased the number of unique peptides found in ocean metaproteome samples by more than 50% when compared to a one-dimension separation while using the same amount of sample and instrument time.
Collapse
Affiliation(s)
- Matthew R McIlvin
- Marine Chemistry and Geochemistry Department, Woods Hole Oceanographic Institution, Woods Hole, Massachusetts 02563, United States
| | - Mak A Saito
- Marine Chemistry and Geochemistry Department, Woods Hole Oceanographic Institution, Woods Hole, Massachusetts 02563, United States
| |
Collapse
|