1
|
Jiang LX, Hilger RT, Laskin J. Hardware and software solutions for implementing nanospray desorption electrospray ionization (nano-DESI) sources on commercial mass spectrometers. JOURNAL OF MASS SPECTROMETRY : JMS 2024; 59:e5065. [PMID: 38866597 DOI: 10.1002/jms.5065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2024] [Revised: 05/14/2024] [Accepted: 05/23/2024] [Indexed: 06/14/2024]
Abstract
Nanospray desorption electrospray ionization (nano-DESI) is an ambient ionization mass spectrometry imaging (MSI) approach that enables spatial mapping of biological and environmental samples with high spatial resolution and throughput. Because nano-DESI has not yet been commercialized, researchers develop their own sources and interface them with different commercial mass spectrometers. Previously, several protocols focusing on the fabrication of nano-DESI probes have been reported. In this tutorial, we discuss different hardware requirements for coupling the nano-DESI source to commercial mass spectrometers, such as the safety interlock, inlet extension, and contact closure. In addition, we describe the structure of our custom software for controlling the nano-DESI MSI platform and provide detailed instructions for its usage. With this tutorial, interested researchers should be able to implement nano-DESI experiments in their labs.
Collapse
Affiliation(s)
- Li-Xue Jiang
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Ryan T Hilger
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Julia Laskin
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| |
Collapse
|
2
|
Zhou Y, Wu Q, Zhao Z, Wang Y, Lu H. Photocatalytic degradation-based ambient mass spectrometry imaging for enhancing detection coverage of poorly-ionizable lipidomes. Talanta 2024; 270:125564. [PMID: 38159350 DOI: 10.1016/j.talanta.2023.125564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/15/2023] [Accepted: 12/16/2023] [Indexed: 01/03/2024]
Abstract
Localization of lipidomes and tracking their spatial changes in tissues by mass spectrometry imaging (MSI) plays an important role in unveiling the mechanisms of living processes, diseases and therapeutic treatments. However, it is always challenging to achieve direct MSI of poorly-ionizable lipids, such as glycolipids and glycerolipids, due to the strong ion suppression and isobaric peaks interference from high-abundance phosphatidylcholines (PCs) in tissues. Here we developed a photocatalytic degradation-based ambient liquid extraction MSI method to largely enhance the detection coverage of poorly-ionizable lipids by rapid online removal of PCs in MSI. Phospholipids were found to be selectively photodegraded on TiO2 surface in acidic conditions in the presence of water under UV irradiation, while other poorly-ionizable lipids remained. Sulfate ion could largely improve the degradation efficiencies. Anatase nanoparticles-embedded TiO2 monolith was in-situ synthesized in the capillary of ambient liquid extraction system, and rapid online photodegradation of PCs was achieved during MSI with efficiency >80 %, largely reducing ion suppression. The pathway analysis showed that PC was oxidatively degraded starting from hydroxylation of C=C bonds. With intense UV irradiation, PCs were completely degraded into small molecules<200 Da without interference on the detection of endogenous lipids. With the new MSI method, detection coverage to cerebrosides, ceramides and diglycerides was enhanced by 2-9 times comparing with traditional MSI. Clearer localizations were observed for poorly-ionizable lipids via the new method than traditional method. Thus, this work provided a complementary MSI method for traditional MSI to address the issues on direct imaging of poorly ionizable lipids in ambient conditions.
Collapse
Affiliation(s)
- Yongchang Zhou
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha, 410083, PR China
| | - Qian Wu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha, 410083, PR China.
| | - Zhihao Zhao
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha, 410083, PR China
| | - Yang Wang
- Laboratory of Ethnopharmacology, Institute of Integrated Traditional Chinese and Western Medicine, Xiangya Hospital, Central South University, Hunan, Changsha, 410008, PR China
| | - Hongmei Lu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha, 410083, PR China
| |
Collapse
|
3
|
Zhao Z, Long Z, Wang H, Wu Q, Wang Y, Lu H. Pulled Flowprobe for Ambient Liquid Extraction-Based High Spatial Resolution Mass Spectrometry Imaging with Enhanced Sensitivity and Stability. Anal Chem 2023; 95:16927-16935. [PMID: 37939311 DOI: 10.1021/acs.analchem.3c03046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
Ambient liquid extraction techniques enable direct mass spectrometry imaging (MSI) under ambient conditions with minimal sample preparation. However, currently an integrated probe for ambient liquid extraction-based MSI with high spatial resolution, high sensitivity, and stability is still lacking. In this work, we developed a new integrated probe made of pulled coaxial capillaries, named pulled flowprobe, and compared it with the previously reported single-probe. Mass transfer kinetics in probes was first investigated. The extraction kinetic curves during probe sampling indicate a narrower and higher peak shape for the pulled flowprobe than single-probe. Computational fluid dynamics analysis reveals that in the pulled flowprobe flow velocities are lower in liquid microjunction and higher in the transferring channels, resulting in higher extraction efficiencies and reduced band diffusion compared with single-probe and other probes with a similar flow route. Results of ambient liquid extraction-based MSI of lipids in rat cerebrum show that signals of low-abundance lipids were 2-5 times higher via a pulled flowprobe than via a single-probe, and 26 more lipid species were detected on brain tissue via a pulled flowprobe than via a single-probe. The stability of MSI with the pulled flowprobe was found to be higher than that with single-probe (averaged relative standard deviation = 18% vs 80%) by imaging a lab-made uniform ink coating. Moreover, in the pulled flowprobe, no retraction of the inner capillary from outer capillary is optimal for both sensitivity and stability. The spatial resolution of the pulled flowprobe (30-40 μm) was measured to be higher than that of a comparable size single-probe by calculation with the "80-20" rule. Finally, the new pulled flowprobe was applied to high-resolution MSI of lipids in the hippocampus, and localization of several lipids to the specific cell layers in the hippocampus region was observed. Thus, this work provides an alternative easily fabricated sampling probe with enhanced sensitivity, stability, and spatial resolution, promoting the use of ambient liquid extraction-based MSI in biological and clinical research.
Collapse
Affiliation(s)
- Zhihao Zhao
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Zheng Long
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Huabei Wang
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Qian Wu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| | - Yang Wang
- Laboratory of Ethnopharmacology, Institute of Integrated Traditional Chinese and Western Medicine, Xiangya Hospital, Central South University, Hunan, Changsha 410008, P. R. China
| | - Hongmei Lu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P. R. China
| |
Collapse
|
4
|
Jiang LX, Polack M, Li X, Yang M, Belder D, Laskin J. A monolithic microfluidic probe for ambient mass spectrometry imaging of biological tissues. LAB ON A CHIP 2023; 23:4664-4673. [PMID: 37782224 PMCID: PMC10823490 DOI: 10.1039/d3lc00637a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 09/25/2023] [Indexed: 10/03/2023]
Abstract
Ambient mass spectrometry imaging (MSI) is a powerful technique that allows for the simultaneous mapping of hundreds of molecules in biological samples under atmospheric conditions, requiring minimal sample preparation. We have developed nanospray desorption electrospray ionization (nano-DESI), a liquid extraction-based ambient ionization technique, which has proven to be sensitive and capable of achieving high spatial resolution. We have previously described an integrated microfluidic probe, which simplifies the nano-DESI setup, but is quite difficult to fabricate. Herein, we introduce a facile and scalable strategy for fabricating microfluidic devices for nano-DESI MSI applications. Our approach involves the use of selective laser-assisted etching (SLE) of fused silica to create a monolithic microfluidic probe (SLE-MFP). Unlike the traditional photolithography-based fabrication, SLE eliminates the need for the wafer bonding process and allows for automated, scalable fabrication of the probe. The chamfered design of the sampling port and ESI emitter significantly reduces the amount of polishing required to fine-tune the probe thereby streamlining and simplifying the fabrication process. We have also examined the performance of a V-shaped probe, in which only the sampling port is fabricated using SLE technology. The V-shaped design of the probe is easy to fabricate and provides an opportunity to independently optimize the size and shape of the electrospray emitter. We have evaluated the performance of SLE-MFP by imaging mouse tissue sections. Our results demonstrate that SLE technology enables the fabrication of robust monolithic microfluidic probes for MSI experiments. This development expands the capabilities of nano-DESI MSI and makes the technique more accessible to the broader scientific community.
Collapse
Affiliation(s)
- Li-Xue Jiang
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| | - Matthias Polack
- Institute of Analytical Chemistry, Leipzig University, Leipzig, 04103, Germany.
| | - Xiangtang Li
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| | - Manxi Yang
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Leipzig, 04103, Germany.
| | - Julia Laskin
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
5
|
Mavroudakis L, Lanekoff I. Identification and Imaging of Prostaglandin Isomers Utilizing MS 3 Product Ions and Silver Cationization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2341-2349. [PMID: 37587718 PMCID: PMC10557378 DOI: 10.1021/jasms.3c00233] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/07/2023] [Accepted: 08/09/2023] [Indexed: 08/18/2023]
Abstract
Prostaglandins (PGs) are important lipid mediators involved in physiological processes, such as inflammation and pregnancy. The pleiotropic effects of the PG isomers and their differential expression from cell types impose the necessity for studying individual isomers locally in tissue to understand the molecular mechanisms. Currently, mass spectrometry (MS)-based analytical workflows for determining the PG isomers typically require homogenization of the sample and a separation method, which results in a loss of spatial information. Here, we describe a method exploiting the cationization of PGs with silver ions for enhanced sensitivity and tandem MS to distinguish the biologically relevant PG isomers PGE2, PGD2, and Δ12-PGD2. The developed method utilizes characteristic product ions in MS3 for training prediction models and is compatible with direct infusion approaches. We discuss insights into the fragmentation pathways of Ag+ cationized PGs during collision-induced dissociation and demonstrate the high accuracy and robustness of the model to predict isomeric compositions of PGs. The developed method is applied to mass spectrometry imaging (MSI) of mouse uterus implantation sites using silver-doped pneumatically assisted nanospray desorption electrospray ionization and indicates localization to the antimesometrial pole and the luminal epithelium of all isomers with different abundances. Overall, we demonstrate, for the first time, isomeric imaging of major PG isomers with a simple method that is compatible with liquid-based extraction MSI methods.
Collapse
Affiliation(s)
| | - Ingela Lanekoff
- Department of Chemistry−BMC, Uppsala University, Uppsala 75123, Sweden
| |
Collapse
|
6
|
Lillja J, Duncan KD, Lanekoff I. Ion-to-Image, i2i, a Mass Spectrometry Imaging Data Analysis Platform for Continuous Ionization Techniques. Anal Chem 2023; 95:11589-11595. [PMID: 37505508 PMCID: PMC10413325 DOI: 10.1021/acs.analchem.3c01615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 07/16/2023] [Indexed: 07/29/2023]
Abstract
Mass spectrometry imaging (MSI) techniques generate data that reveal spatial distributions of molecules on a surface with high sensitivity and selectivity. However, processing large volumes of mass spectrometry data into useful ion images is not trivial. Furthermore, data from MSI techniques using continuous ionization sources where data are acquired in line scans require different data handling strategies compared to data collected from pulsed ionization sources where data are acquired in grids. In addition, for continuous ionization sources, the pixel dimensions are influenced by the mass spectrometer duty cycle, which, in turn, can be controlled by the automatic gain control (AGC) for each spectrum (pixel). Currently, there is a lack of data-handling software for MSI data generated with continuous ionization sources and AGC. Here, we present ion-to-image (i2i), which is a MATLAB-based application for MSI data acquired with continuous ionization sources, AGC, high resolution, and one or several scan filters. The source code and a compiled installer are available at https://github.com/LanekoffLab/i2i. The application includes both quantitative, targeted, and nontargeted data processing strategies and enables complex data sets to be processed in minutes. The i2i application has high flexibility for generating, processing, and exporting MSI data both from simple full scans and more complex scan functions interlacing MSn and SIM scan data sets, and we anticipate that it will become a valuable addition to the existing MSI software toolbox.
Collapse
Affiliation(s)
- Johan Lillja
- Department
of Chemistry − BMC, Uppsala University, Uppsala, 752 37, Sweden
| | - Kyle D. Duncan
- Department
of Chemistry − BMC, Uppsala University, Uppsala, 752 37, Sweden
- Department
of Chemistry, Vancouver Island University, Nanaimo, British Columbia V9R 5S5, Canada
| | - Ingela Lanekoff
- Department
of Chemistry − BMC, Uppsala University, Uppsala, 752 37, Sweden
| |
Collapse
|
7
|
Yang M, Unsihuay D, Hu H, Nguele Meke F, Qu Z, Zhang ZY, Laskin J. Nano-DESI Mass Spectrometry Imaging of Proteoforms in Biological Tissues with High Spatial Resolution. Anal Chem 2023; 95:5214-5222. [PMID: 36917636 DOI: 10.1021/acs.analchem.2c04795] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
Mass spectrometry imaging (MSI) is a powerful tool for label-free mapping of the spatial distribution of proteins in biological tissues. We have previously demonstrated imaging of individual proteoforms in biological tissues using nanospray desorption electrospray ionization (nano-DESI), an ambient liquid extraction-based MSI technique. Nano-DESI MSI generates multiply charged protein ions, which is advantageous for their identification using top-down proteomics analysis. In this study, we demonstrate proteoform mapping in biological tissues with a spatial resolution down to 7 μm using nano-DESI MSI. A substantial decrease in protein signals observed in high-spatial-resolution MSI makes these experiments challenging. We have enhanced the sensitivity of nano-DESI MSI experiments by optimizing the design of the capillary-based probe and the thickness of the tissue section. In addition, we demonstrate that oversampling may be used to further improve spatial resolution at little or no expense to sensitivity. These developments represent a new step in MSI-based spatial proteomics, which complements targeted imaging modalities widely used for studying biological systems.
Collapse
Affiliation(s)
- Manxi Yang
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Daisy Unsihuay
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Hang Hu
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Frederick Nguele Meke
- Department of Medicinal Chemistry and Molecular Pharmacology, Purdue University, West Lafayette, Indiana 47907, United States
| | - Zihan Qu
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.,Department of Medicinal Chemistry and Molecular Pharmacology, Purdue University, West Lafayette, Indiana 47907, United States
| | - Zhong-Yin Zhang
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.,Department of Medicinal Chemistry and Molecular Pharmacology, Purdue University, West Lafayette, Indiana 47907, United States
| | - Julia Laskin
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
8
|
Mavroudakis L, Lanekoff I. Ischemic Stroke Causes Disruptions in the Carnitine Shuttle System. Metabolites 2023; 13:metabo13020278. [PMID: 36837897 PMCID: PMC9968086 DOI: 10.3390/metabo13020278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/20/2023] [Accepted: 02/11/2023] [Indexed: 02/17/2023] Open
Abstract
Gaining a deep understanding of the molecular mechanisms underlying ischemic stroke is necessary to develop treatment alternatives. Ischemic stroke is known to cause a cellular energy imbalance when glucose supply is deprived, enhancing the role for energy production via β-oxidation where acylcarnitines are essential for the transportation of fatty acids into the mitochondria. Although traditional bulk analysis methods enable sensitive detection of acylcarnitines, they do not provide information on their abundances in various tissue regions. However, with quantitative mass spectrometry imaging the detected concentrations and spatial distributions of endogenous molecules can be readily obtained in an unbiased way. Here, we use pneumatically assisted nanospray desorption electrospray ionization mass spectrometry imaging (PA nano-DESI MSI) doped with internal standards to study the distributions of acylcarnitines in mouse brain affected by stroke. The internal standards enable quantitative imaging and annotation of endogenous acylcarnitines is achieved by studying fragmentation patterns. We report a significant accumulation of long-chain acylcarnitines due to ischemia in brain tissue of the middle cerebral artery occlusion (MCAO) stroke model. Further, we estimate activities of carnitine transporting enzymes and demonstrate disruptions in the carnitine shuttle system that affects the β-oxidation in the mitochondria. Our results show the importance for quantitative monitoring of metabolite distributions in distinct tissue regions to understand cell compensation mechanisms involved in handling damage caused by stroke.
Collapse
|
9
|
Mavroudakis L, Lanekoff I. Matrix Effects Free Imaging of Thin Tissue Sections Using Pneumatically Assisted Nano-DESI MSI. Methods Mol Biol 2023; 2688:107-121. [PMID: 37410288 DOI: 10.1007/978-1-0716-3319-9_10] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/07/2023]
Abstract
Mass spectrometry imaging has the potential to reveal important molecular interaction in morphological regions in tissue. However, the simultaneous ionization of the continuously altered and complex chemistry in each pixel can introduce artifacts that result in skewed molecular distributions in the compiled ion images. These artifacts are known as matrix effects. Mass spectrometry imaging using nanospray desorption electrospray ionization (nano-DESI MSI) enables the elimination of matrix effects by doping the nano-DESI solvent with internal standards. Carefully selected internal standards ionize similarly and simultaneously with the extracted analytes from thin tissue sections, and the matrix effects are eliminated through a robust data normalization method. Herein we describe the setup and use of pneumatically assisted (PA) nano-DESI MSI with standards doped in the solvent for elimination of matrix effects in ion images.
Collapse
Affiliation(s)
| | - Ingela Lanekoff
- Department of Chemistry - BMC, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
10
|
Quantitative determination of sn-positional phospholipid isomers in MS n using silver cationization. Anal Bioanal Chem 2022; 414:7473-7482. [PMID: 35731255 PMCID: PMC9482905 DOI: 10.1007/s00216-022-04173-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 05/13/2022] [Accepted: 06/09/2022] [Indexed: 11/18/2022]
Abstract
Glycerophospholipids are one of the fundamental building blocks for life. The acyl chain connectivity to the glycerol backbone constitutes different sn-positional isomers, which have great diversity and importance for biological function. However, to fully realize their impact on function, analytical techniques that can identify and quantify sn-positional isomers in chemically complex biological samples are needed. Here, we utilize silver ion cationization in combination with tandem mass spectrometry (MSn) to identify sn-positional isomers of phosphatidylcholine (PC) species. In particular, a labile carbocation is generated through a neutral loss (NL) of AgH, the dissociation of which provides diagnostic product ions that correspond to acyl chains at the sn-1 or sn-2 position. The method is comparable to currently available methods, has a sensitivity in the nM–µM range, and is compatible with quantitative imaging using mass spectrometry in MS4. The results reveal a large difference in isomer concentrations and the ion images show that the sn-positional isomers PC 18:1_18:0 are homogeneously distributed, whereas PC 18:1_16:0 and PC 20:1_16:0 show distinct localizations to sub-hippocampal structures.
Collapse
|
11
|
Vandergrift GW, Kew W, Lukowski JK, Bhattacharjee A, Liyu AV, Shank EA, Paša-Tolić L, Prabhakaran V, Anderton CR. Imaging and Direct Sampling Capabilities of Nanospray Desorption Electrospray Ionization with Absorption-Mode 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Anal Chem 2022; 94:3629-3636. [PMID: 35167251 DOI: 10.1021/acs.analchem.1c05216] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Nanospray desorption electrospray ionization mass spectrometry, a powerful ambient sampling and imaging technique, is herein coupled as an isolated source with 21 Tesla (21T) Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). Absorption-mode data, enabled by an external data acquisition system, is applied for improved mass resolution, accuracy, and dynamic range without compromising spectral acquisition rates. Isotopic fine structure (IFS) information is obtained from the ambient sampling of living Bacillus and Fusarium species, allowing for high confidence in molecular annotations with a resolution >830 k (at m/z 825). Tandem mass spectrometry experiments for biological samples are shown to retain the IFS in addition to gained fragmentation information, providing a further degree of annotation confidence from ambient analyses. Rat brain was imaged by nanospray desorption electrospray ionization (nano-DESI) 21T FTICR MS in ∼5 h using 768 ms transients, producing over 800 molecular annotations using the METASPACE platform and low-parts-per-billion mass accuracy at a spatial resolution of ∼25 × 180 μm. Finally, nano-DESI 21T FTICR MS imaging is demonstrated to reveal images corresponding to the IFS, as well as hundreds of additional molecular features (including demonstrated differences as low as 8.96 mDa) that are otherwise undetected by a more conventional imaging methodology.
Collapse
Affiliation(s)
- Gregory W Vandergrift
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - William Kew
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Jessica K Lukowski
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Arunima Bhattacharjee
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Andrey V Liyu
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Elizabeth A Shank
- University of Massachusetts Chan Medical School, Worcester, Massachusetts 01655, United States
| | - Ljiljana Paša-Tolić
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Venkateshkumar Prabhakaran
- Physical Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.,The Gene & Linda Voil and School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Christopher R Anderton
- Environmental Molecular Sciences Laboratory and Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| |
Collapse
|
12
|
Biosynthesis-based spatial metabolome of Salvia miltiorrhiza Bunge by combining metabolomics approaches with mass spectrometry-imaging. Talanta 2022; 238:123045. [PMID: 34801902 DOI: 10.1016/j.talanta.2021.123045] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 11/03/2021] [Accepted: 11/05/2021] [Indexed: 11/21/2022]
Abstract
Defining the spatial distributions of metabolites and their structures are the two key aspects for interpreting the complexities of biosynthesis pathways in plants. As a means of obtaining information on the spatial distribution of metabolites, a strategy is needed that has high sensitivity and allows visualization. Toward this goal, we carried an untargeted metabolomics to obtain detailed metabolic information on different plant parts of Salvia miltiorrhiza, the roots of which are widely used in traditional Chinese medicine. Systematic optimization of desorption electrospray ionization mass spectrometry imaging (DESI-MSI) including parameter selection and sample preparation were carried out to improve the sensitivity of the method for plant samples. Guided by the metabolomics data, the spatial distributions of diverse metabolites, including phenolic acids, flavonoids, tanshinones, carbohydrates, and lipids, were characterized and visualized for both the underground and aerial parts. To integrate the information pertaining to the spatial distribution of metabolites, the flavonoids and phenolic acids (phenylpropanoid metabolic pathway) were chosen as examples for in-depth study the biosynthesis pathways in S. miltiorrhiza. The complementary data obtained from the metabolomics study and mass spectrometry imaging enabled the identification of key reactions involved in flavonoid biosynthesis in flowers, which lead the changes in metabolite distribution. The analysis also identified the core precursor for phenolic acid biosynthesis in Salvia species. Therefore, the powerful combination of metabolomics and mass spectrometry imaging provides a basis for obtaining detailed information on spatial metabolome and constitutes a platform for deep understanding the biosynthesis of bioactive metabolites in plants.
Collapse
|
13
|
Lillja J, Lanekoff I. Silver-Doped Nano-DESI MSI for Increased Specificity and Sensitivity of Alkenes. METHODS IN MOLECULAR BIOLOGY (CLIFTON, N.J.) 2022; 2437:241-249. [PMID: 34902153 DOI: 10.1007/978-1-0716-2030-4_17] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Nanospray desorption electrospray ionization (nano-DESI) is a technique that can be used for mass spectrometry imaging (MSI) experiments. Due to the separation of sampling and ionization events, the nano-DESI solvent can be doped with additives to alter the specificity and selectivity of the experiment. In this chapter, we describe the addition of silver ions to the nano-DESI solvent for increased specificity and sensitivity of double bond containing analyte molecules for nano-DESI MSI.
Collapse
Affiliation(s)
- Johan Lillja
- Department of Chemistry - BMC, Uppsala University, Uppsala, Sweden
| | - Ingela Lanekoff
- Department of Chemistry - BMC, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
14
|
Localization and Absolute Quantification of Dopamine in Discrete Intravesicular Compartments Using NanoSIMS Imaging. Int J Mol Sci 2021; 23:ijms23010160. [PMID: 35008583 PMCID: PMC8745556 DOI: 10.3390/ijms23010160] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 12/22/2021] [Accepted: 12/22/2021] [Indexed: 11/17/2022] Open
Abstract
The absolute concentration and the compartmentalization of analytes in cells and organelles are crucial parameters in the development of drugs and drug delivery systems, as well as in the fundamental understanding of many cellular processes. Nanoscale secondary ion mass spectrometry (NanoSIMS) imaging is a powerful technique which allows subcellular localization of chemical species with high spatial and mass resolution, and high sensitivity. In this study, we combined NanoSIMS imaging with spatial oversampling with transmission electron microscopy (TEM) imaging to discern the compartments (dense core and halo) of large dense core vesicles in a model cell line used to study exocytosis, and to localize 13C dopamine enrichment following 4–6 h of 150 μM 13C L-3,4-dihydroxyphenylalanine (L-DOPA) incubation. In addition, the absolute concentrations of 13C dopamine in distinct vesicle domains as well as in entire single vesicles were quantified and validated by comparison to electrochemical data. We found concentrations of 87.5 mM, 16.0 mM and 39.5 mM for the dense core, halo and the whole vesicle, respectively. This approach adds to the potential of using combined TEM and NanoSIMS imaging to perform absolute quantification and directly measure the individual contents of nanometer-scale organelles.
Collapse
|
15
|
Recent Advances of Ambient Mass Spectrometry Imaging and Its Applications in Lipid and Metabolite Analysis. Metabolites 2021; 11:metabo11110780. [PMID: 34822438 PMCID: PMC8625079 DOI: 10.3390/metabo11110780] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 11/08/2021] [Accepted: 11/11/2021] [Indexed: 01/02/2023] Open
Abstract
Ambient mass spectrometry imaging (AMSI) has attracted much attention in recent years. As a kind of unlabeled molecular imaging technique, AMSI can enable in situ visualization of a large number of compounds in biological tissue sections in ambient conditions. In this review, the developments of various AMSI techniques are discussed according to one-step and two-step ionization strategies. In addition, recent applications of AMSI for lipid and metabolite analysis (from 2016 to 2021) in disease diagnosis, animal model research, plant science, drug metabolism and toxicology research, etc., are summarized. Finally, further perspectives of AMSI in spatial resolution, sensitivity, quantitative ability, convenience and software development are proposed.
Collapse
|
16
|
Lillja J, Duncan KD, Lanekoff I. Determination of Monounsaturated Fatty Acid Isomers in Biological Systems by Modeling MS 3 Product Ion Patterns. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2479-2487. [PMID: 32677833 DOI: 10.1021/jasms.0c00194] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Unsaturated free fatty acids are natively present in biological samples as isomers, where double bonds can be situated on different carbons in the acyl chain. While these isomers can have different actions and impacts on biological systems, they are inherently difficult to identify and differentiate by mass spectrometry alone. To address this challenge, several techniques for derivatization of the double bond or metal cationization at the carboxylic group have yielded diagnostic product ions for the respective isomer in tandem mass spectrometry. However, diagnostic product ions do not necessarily reflect quantitative isomeric ratios since fatty acid isomers have different ionization and fragmentation efficiencies. Here, we introduce a simple and rapid approach to predict the quantitative ratio of isomeric monounsaturated fatty acids. Specifically, empirically derived MS3 product ion patterns from fatty acid silver adducts are modeled using a stepwise linear model. This model is then applied to predict the proportion oleic and vaccenic acid in chemically complex samples at individual concentrations between 0.45 and 5.25 μM, with an average accuracy and precision below 2 and 5 mol %, respectively. We show that by simply including silver ions in the electrospray solvent, isomeric ratios are rapidly predicted in neat standards, rodent plasma, and tissue extract. Furthermore, we use the method to directly map isomeric ratios in tissue sections using nanospray desorption electrospray ionization MS3 imaging without any sample preparation or modification to the instrumental setup. Ultimately, this approach provides a simple and rapid solution to differentiate monounsaturated fatty acids using commonly available commercial mass spectrometers without any instrumental modifications.
Collapse
Affiliation(s)
- Johan Lillja
- Department of Chemistry - BMC, Uppsala University, 751 24 Uppsala, Sweden
| | - Kyle D Duncan
- Department of Chemistry - BMC, Uppsala University, 751 24 Uppsala, Sweden
| | - Ingela Lanekoff
- Department of Chemistry - BMC, Uppsala University, 751 24 Uppsala, Sweden
| |
Collapse
|
17
|
Li N, Nie H, Jiang L, Ruan G, Du F, Liu H. Recent advances of ambient ionization mass spectrometry imaging in clinical research. J Sep Sci 2020; 43:3146-3163. [PMID: 32573988 DOI: 10.1002/jssc.202000273] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/03/2020] [Accepted: 05/06/2020] [Indexed: 02/06/2023]
Abstract
The structural information and spatial distribution of molecules in biological tissues are closely related to the potential molecular mechanisms of disease origin, transfer, and classification. Ambient ionization mass spectrometry imaging is an effective tool that provides molecular images while describing in situ information of biomolecules in complex samples, in which ionization occurs at atmospheric pressure with the samples being analyzed in the native state. Ambient ionization mass spectrometry imaging can directly analyze tissue samples at a fairly high resolution to obtain molecules in situ information on the tissue surface to identify pathological features associated with a disease, resulting in the wide applications in pharmacy, food science, botanical research, and especially clinical research. Herein, novel ambient ionization techniques, such as techniques based on spray and solid-liquid extraction, techniques based on plasma desorption, techniques based on laser desorption ablation, and techniques based on acoustic desorption were introduced, and the data processing of ambient ionization mass spectrometry imaging was briefly reviewed. Besides, we also highlight recent applications of this imaging technology in clinical researches and discuss the challenges in this imaging technology and the perspectives on the future of the clinical research.
Collapse
Affiliation(s)
- Na Li
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, P. R. China
- College of Chemistry and Molecular Engineering, Peking University, Beijing, P. R. China
| | - Honggang Nie
- College of Chemistry and Molecular Engineering, Peking University, Beijing, P. R. China
| | - Liping Jiang
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, P. R. China
| | - Guihua Ruan
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, P. R. China
| | - Fuyou Du
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, P. R. China
- College of Biological and Environmental Engineering, Changsha University, Changsha, P. R. China
| | - Huwei Liu
- College of Chemistry and Molecular Engineering, Peking University, Beijing, P. R. China
| |
Collapse
|
18
|
High spatial resolution imaging of biological tissues using nanospray desorption electrospray ionization mass spectrometry. Nat Protoc 2019; 14:3445-3470. [PMID: 31723300 DOI: 10.1038/s41596-019-0237-4] [Citation(s) in RCA: 102] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 08/27/2019] [Indexed: 11/08/2022]
Abstract
Mass spectrometry imaging (MSI) enables label-free spatial mapping of hundreds of biomolecules in tissue sections. This capability provides valuable information on tissue heterogeneity that is difficult to obtain using population-averaged assays. Despite substantial developments in both instrumentation and methodology, MSI of tissue samples at single-cell resolution remains challenging. Herein, we describe a protocol for robust imaging of tissue sections with a high (better than 10-μm) spatial resolution using nanospray desorption electrospray ionization (nano-DESI) mass spectrometry, an ambient ionization technique that does not require sample pretreatment before analysis. In this protocol, mouse uterine tissue is used as a model system to illustrate both the workflow and data obtained in these experiments. We provide a detailed description of the nano-DESI MSI platform, fabrication of the nano-DESI and shear force probes, shear force microscopy experiments, spectral acquisition, and data processing. A properly trained researcher (e.g., technician, graduate student, or postdoc) can complete all the steps from probe fabrication to data acquisition and processing within a single day. We also describe a new strategy for acquiring both positive- and negative-mode imaging data in the same experiment. This is achieved by alternating between positive and negative data acquisition modes during consecutive line scans. Using our imaging approach, hundreds of high-quality ion images were obtained from a single uterine section. This protocol enables sensitive and quantitative imaging of lipids and metabolites in heterogeneous tissue sections with high spatial resolution, which is critical to understanding biochemical processes occurring in biological tissues.
Collapse
|
19
|
Suárez PL, García-Cortés M, Fernández-Argüelles MT, Encinar JR, Valledor M, Ferrero FJ, Campo JC, Costa-Fernández JM. Functionalized phosphorescent nanoparticles in (bio)chemical sensing and imaging – A review. Anal Chim Acta 2019; 1046:16-31. [DOI: 10.1016/j.aca.2018.08.018] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 07/03/2018] [Accepted: 08/06/2018] [Indexed: 01/19/2023]
|
20
|
Duncan KD, Fang R, Yuan J, Chu RK, Dey SK, Burnum-Johnson KE, Lanekoff I. Quantitative Mass Spectrometry Imaging of Prostaglandins as Silver Ion Adducts with Nanospray Desorption Electrospray Ionization. Anal Chem 2018; 90:7246-7252. [PMID: 29676905 DOI: 10.1021/acs.analchem.8b00350] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Prostaglandins (PG) are an important class of lipid biomolecules that are essential in many biological processes, including inflammation and successful pregnancy. Despite a high bioactivity, physiological concentrations are typically low, which makes direct mass spectrometric analysis of endogenous PG species challenging. Consequently, there have not been any studies investigating PG localization to specific morphological regions in tissue sections using mass spectrometry imaging (MSI) techniques. Herein, we show that silver ions, added to the solvent used for nanospray desorption electrospray ionization (nano-DESI) MSI, enhances the ionization of PGs and enables nano-DESI MSI of several species in uterine tissue from day 4 pregnant mice. It was found that detection of [PG + Ag]+ ions increased the sensitivity by ∼30 times, when compared to [PG - H]- ions. Further, the addition of isotopically labeled internal standards enabled generation of quantitative ion images for the detected PG species. Increased sensitivity and quantitative MSI enabled the first proof-of-principle results detailing PG localization in mouse uterus tissue sections. These results show that PG species primarily localized to cellular regions of the luminal epithelium and glandular epithelium in uterine tissue. Further, this study provides a unique scaffold for future studies investigating the PG distribution within biological tissue samples.
Collapse
Affiliation(s)
- Kyle D Duncan
- Department of Chemistry-BMC , Uppsala University , SE-751 24 Uppsala , Sweden
| | - Ru Fang
- Department of Chemistry-BMC , Uppsala University , SE-751 24 Uppsala , Sweden
| | - Jia Yuan
- Division of Reproductive Sciences , Cincinnati Children's Hospital Medical Center , Cincinnati , Ohio 45229 , United States
| | - Rosalie K Chu
- Biological Sciences Division , Pacific Northwest National Laboratory , Richland , Washington 99352 , United States
| | - Sudhansu K Dey
- Division of Reproductive Sciences , Cincinnati Children's Hospital Medical Center , Cincinnati , Ohio 45229 , United States
| | - Kristin E Burnum-Johnson
- Biological Sciences Division , Pacific Northwest National Laboratory , Richland , Washington 99352 , United States
| | - Ingela Lanekoff
- Department of Chemistry-BMC , Uppsala University , SE-751 24 Uppsala , Sweden
| |
Collapse
|