1
|
Onffroy P, Chiovoloni S, Kuo HL, Saccone MA, Lu JQ, DeSimone JM. Opportunities at the Intersection of 3D Printed Polymers and Pyrolysis for the Microfabrication of Carbon-Based Energy Materials. JACS AU 2024; 4:3706-3726. [PMID: 39483227 PMCID: PMC11522932 DOI: 10.1021/jacsau.4c00555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 09/14/2024] [Accepted: 09/16/2024] [Indexed: 11/03/2024]
Abstract
In an era marked by a growing demand for sustainable and high-performance materials, the convergence of additive manufacturing (AM), also known as 3D printing, and the thermal treatment, or pyrolysis, of polymers to form high surface area hierarchically structured carbon materials stands poised to catalyze transformative advancements across a spectrum of electrification and energy storage applications. Designing 3D printed polymers using low-cost resins specifically for conversion to high performance carbon structures via post-printing thermal treatments overcomes the challenges of 3D printing pure carbon directly due to the inability of pure carbon to be polymerized, melted, or sintered under ambient conditions. In this perspective, we outline the current state of AM methods that have been used in combination with pyrolysis to generate 3D carbon structures and highlight promising systems to explore further. As part of this endeavor, we discuss the effects of 3D printed polymer chemistry composition, additives, and pyrolysis conditions on resulting 3D pyrolytic carbon properties. Furthermore, we demonstrate the viability of combining continuous liquid interface production (CLIP) vat photopolymerization with pyrolysis as a promising avenue for producing 3D pyrolytic carbon lattice structures with 15 μm feature resolution, paving way for 3D carbon-based sustainable energy applications.
Collapse
Affiliation(s)
- Philip
R. Onffroy
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Samuel Chiovoloni
- Department
of Materials Science & Engineering, University of California, Merced, Merced, California 95343, United States
| | - Han Lin Kuo
- Department
of Materials Science & Engineering, University of California, Merced, Merced, California 95343, United States
| | - Max A. Saccone
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
- Department
of Radiology, Stanford University, Stanford California 94305, United States
- Department
of Mechanical Engineering, University of
Colorado Boulder, Boulder, Colorado 80309, United States
| | - Jennifer Q. Lu
- Department
of Materials Science & Engineering, University of California, Merced, Merced, California 95343, United States
| | - Joseph M. DeSimone
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
- Department
of Radiology, Stanford University, Stanford California 94305, United States
| |
Collapse
|
2
|
Martinez-Duarte R, Mager D, Korvink JG, Islam M. Evaluating carbon-electrode dielectrophoresis under the ASSURED criteria. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:922737. [PMID: 35958120 PMCID: PMC9360481 DOI: 10.3389/fmedt.2022.922737] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 07/07/2022] [Indexed: 11/30/2022] Open
Abstract
Extreme point-of-care refers to medical testing in unfavorable conditions characterized by a lack of primary resources or infrastructure. As witnessed in the recent past, considerable interest in developing devices and technologies exists for extreme point-of-care applications, for which the World Health Organization has introduced a set of encouraging and regulating guidelines. These are referred to as the ASSURED criteria, an acronym for Affordable (A), Sensitive (S), Specific (S), User friendly (U), Rapid and Robust (R), Equipment-free (E), and Delivered (D). However, the current extreme point of care devices may require an intermediate sample preparation step for performing complex biomedical analysis, including the diagnosis of rare-cell diseases and early-stage detection of sepsis. This article assesses the potential of carbon-electrode dielectrophoresis (CarbonDEP) for sample preparation competent in extreme point-of-care, following the ASSURED criteria. We first discuss the theory and utility of dielectrophoresis (DEP) and the advantages of using carbon microelectrodes for this purpose. We then critically review the literature relevant to the use of CarbonDEP for bioparticle manipulation under the scope of the ASSURED criteria. Lastly, we offer a perspective on the roadmap needed to strengthen the use of CarbonDEP in extreme point-of-care applications.
Collapse
Affiliation(s)
- Rodrigo Martinez-Duarte
- Multiscale Manufacturing Laboratory, Mechanical Engineering Department, Clemson University, Clemson, SC, United States
- *Correspondence: Rodrigo Martinez-Duarte
| | - Dario Mager
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - Jan G. Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
- Jan G. Korvink
| | - Monsur Islam
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
- Monsur Islam
| |
Collapse
|
3
|
Martinez-Duarte R. A critical review on the fabrication techniques that can enable higher throughput in dielectrophoresis devices. Electrophoresis 2021; 43:232-248. [PMID: 34523166 DOI: 10.1002/elps.202100179] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 08/29/2021] [Accepted: 09/01/2021] [Indexed: 01/11/2023]
Abstract
The sorting of targeted cells in a sample is a cornerstone of healthcare diagnostics and therapeutics. This work focuses on the use of dielectrophoresis for the selective sorting of targeted bioparticles in a sample and how the lack of throughput has been one important practical challenge to its widespread practical implementation. Increasing the cross-sectional area of a channel can lead to higher flow rates and thus the capability to process a larger sample volume per unit of time. However, the required electric field gradient that is generated by polarized electrodes drastically decreases as one moves away from the electrodes. Hence, the scaling up of the channel cross section must be done asymmetrically. One desires a channel aspect ratio AR = height/width that is much smaller or much larger than 1. Since reducing footprint of the DEP device is important to ensure affordability, the use of channels with AR>>1 is desired. This creates the challenge to fabricate electrodes on the sidewalls of multiple channels with AR>>1, or a channel embedding an array of electrodes with a gap in between them with AR >>1. This critical review first details the motivation for using three-dimensional (3D) DEP devices to improve throughput and then describes selected techniques that have been used to fabricate them. Techniques include electrodeposition, deep etching, thick-film photolithography, and co-fabrication. Electrode materials addressed include metals, silicon, carbon, PDMS-based composites as well as conductive polymers and fluids.
Collapse
Affiliation(s)
- Rodrigo Martinez-Duarte
- Multiscale Manufacturing Laboratory, Department of Mechanical Engineering, Clemson University, Clemson, South Carolina, 29634, USA
| |
Collapse
|
4
|
Kwizera EA, Sun M, White AM, Li J, He X. Methods of Generating Dielectrophoretic Force for Microfluidic Manipulation of Bioparticles. ACS Biomater Sci Eng 2021; 7:2043-2063. [PMID: 33871975 PMCID: PMC8205986 DOI: 10.1021/acsbiomaterials.1c00083] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Manipulation of microscale bioparticles including living cells is of great significance to the broad bioengineering and biotechnology fields. Dielectrophoresis (DEP), which is defined as the interactions between dielectric particles and the electric field, is one of the most widely used techniques for the manipulation of bioparticles including cell separation, sorting, and trapping. Bioparticles experience a DEP force if they have a different polarization from the surrounding media in an electric field that is nonuniform in terms of the intensity and/or phase of the electric field. A comprehensive literature survey shows that the DEP-based microfluidic devices for manipulating bioparticles can be categorized according to the methods of creating the nonuniformity via patterned microchannels, electrodes, and media to generate the DEP force. These methods together with the theory of DEP force generation are described in this review, to provide a summary of the methods and materials that have been used to manipulate various bioparticles for various specific biological outcomes. Further developments of DEP-based technologies include identifying materials that better integrate with electrodes than current popular materials (silicone/glass) and improving the performance of DEP manipulation of bioparticles by combining it with other methods of handling bioparticles. Collectively, DEP-based microfluidic manipulation of bioparticles holds great potential for various biomedical applications.
Collapse
Affiliation(s)
- Elyahb A. Kwizera
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Mingrui Sun
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, USA
| | - Alisa M. White
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| | - Jianrong Li
- Department of Veterinary Biosciences, The Ohio State University, Columbus, OH 43210, USA
| | - Xiaoming He
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, USA
- Robert E. Fischell Institute for Biomedical Devices, University of Maryland, College Park, MD 20742, USA
- Marlene and Stewart Greenebaum Comprehensive Cancer Center, University of Maryland, Baltimore, MD 21201, USA
| |
Collapse
|
5
|
Characterization of the Dielectrophoretic Response of Different Candida Strains Using 3D Carbon Microelectrodes. MICROMACHINES 2020; 11:mi11030255. [PMID: 32121163 PMCID: PMC7143313 DOI: 10.3390/mi11030255] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 02/23/2020] [Accepted: 02/26/2020] [Indexed: 02/08/2023]
Abstract
Bloodstream infection with Candida fungal cells remains one of the most life-threatening complications among hospitalized patients around the world. Although most of the cases are still due to Candida albicans, the rising incidence of infections caused by other Candida strains that may not respond to traditional anti-fungal treatments merits the development of a method for species-specific isolation of Candida. To this end, here we present the characterization of the dielectrophoresis (DEP) response of Candida albicans, Candida tropicalis and Candida parapsilosis. We complement such characterization with a study of the Candida cells morphology. The Candida strains exhibited subtle differences in their morphology and dimensions. All the Candida strains exhibited positive DEP in the range 10-500 kHz, although the strength of the DEP response was different for each Candida strain at different frequencies. Only Candida tropicalis showed positive DEP at 750 kHz. The current results show potential for manipulation and enrichment of a specific Candida strain at specific DEP conditions towards aiding in the rapid identification of Candida strains to enable the effective and timely treatment of Candida infections.
Collapse
|
6
|
Natu R, Islam M, Keck D, Martinez-Duarte R. Automated "pick and transfer" of targeted cells using dielectrophoresis. LAB ON A CHIP 2019; 19:2512-2525. [PMID: 31259984 DOI: 10.1039/c9lc00409b] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Selective manipulation of single cells is an important step in sample preparation for biological analysis. A highly specific and automated device is desired for such an operation. An ideal device would be able to selectively pick several single cells in parallel from a heterogeneous population and transfer those to designated sites for further analysis without human intervention. The robotic manipulator developed here provides the basis for development of such a device. The device in this work is designed to selectively pick cells based on their inherent properties using dielectrophoresis (DEP) and automatically transfer and release those at a transfer site. Here we provide proof of concept of such a device and study the effect of different parameters on its operation. Successful experiments were conducted to separate Candida cells from a mixture with 10 μm latex particles and a viability assay was performed for separation of viable rat adipose stem cells (RASCs) from non-viable ones. The robotic DEP device was further used to pick and transfer single RASCs. This work also discusses the advantages and disadvantages of our current setup and illustrates the future steps required to improve the performance of this robotic DEP technology.
Collapse
Affiliation(s)
- Rucha Natu
- Multiscale Manufacturing Laboratory, Department of Mechanical Engineering, Clemson University, SC 29634, USA.
| | - Monsur Islam
- Multiscale Manufacturing Laboratory, Department of Mechanical Engineering, Clemson University, SC 29634, USA. and Karlsruhe Institute of Technology, Institute of Microstructure Technology, Hermann-von-Helmholtz-Platz 1 76344, Eggenstein-Leopoldshafen, Germany
| | - Devin Keck
- Multiscale Manufacturing Laboratory, Department of Mechanical Engineering, Clemson University, SC 29634, USA.
| | - Rodrigo Martinez-Duarte
- Multiscale Manufacturing Laboratory, Department of Mechanical Engineering, Clemson University, SC 29634, USA.
| |
Collapse
|