1
|
Sharafatdoust Asl A, Zabetian Targhi M, Zeaei S, Halvaei I, Nosrati R. High-throughput selection of sperm with improved DNA integrity and rapidly progressive motility using a butterfly-shaped chip compared to the swim-up method. LAB ON A CHIP 2024. [PMID: 39314182 DOI: 10.1039/d4lc00506f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/25/2024]
Abstract
Microfluidics provides unique opportunities for the high throughput selection of motile sperm with improved DNA integrity for assisted reproductive technologies (ARTs). Here, through a parametric study on dimensions and geometrical angles, a butterfly-shaped chip (BSC) is presented to isolate sperm with high progressive motility and intact DNA at a separation rate of 1125 sperm per minute. Using finite element simulations, the flow field and shear rates in the device were optimized to leverage the inherent motility characteristics of sperm for maximum selection throughput. The device incorporates a triple selection mechanism in series, initially activating sperm rheotaxis by rotation against the semen flow, penetrating the counter buffer flow and swimming against the direction of the buffer flow, leaving dead cells and debris behind, and subsequently leveraging boundary-following behavior to direct progressively motile sperm to swim along the walls and reach the device outlet. The device selects over 4.1 million sperm per mL within 20 minutes, with 29.2%, 68.2%, and 57.3% improvement in total motility, DNA integrity, and velocity parameter (VCL), as compared with the conventional swim-up method, respectively. Overall, the performance of the device to separate sperm with approximately 95.9% total motility, 97.8% viability, and 96.6% DNA integrity at high concentrations demonstrates its potential for enhancing the efficiency of conventional treatment methods.
Collapse
Affiliation(s)
| | | | - Soroush Zeaei
- Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran.
| | - Iman Halvaei
- Department of Anatomical Sciences, Tarbiat Modares University, Tehran, Iran.
| | - Reza Nosrati
- Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Australia.
| |
Collapse
|
2
|
Ma J, Xie Q, Zhang Y, Xiao Q, Liu X, Qiao C, Tian Y. Advances in microfluidic technology for sperm screening and in vitro fertilization. Anal Bioanal Chem 2024; 416:3717-3735. [PMID: 38189916 DOI: 10.1007/s00216-023-05120-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/09/2023] [Accepted: 12/19/2023] [Indexed: 01/09/2024]
Abstract
About 18% of reproductive-age adults worldwide are affected by infertility. In vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI) are widely used assisted reproductive technologies (ARTs) aimed at improving clinical outcomes. Efficient and noninvasive selection and isolation of highly motile sperm with intact DNA are essential for the success of IVF and ICSI and can potentially impact the therapeutic efficacy and the health of the offspring. Compared to traditional methods, microfluidic technology offers significant advantages such as low sample consumption, high efficiency, minimal damage, high integration, similar microenvironment, and high automation, providing a new platform for ARTs. Here, we review the current situation of microfluidic technology in the field of sperm motility screening and evaluation and IVF research. First, we focus on the working principle, structural design, and screening results of sperm selection microfluidic platforms. We then highlight how the multiple steps of the IVF process can be facilitated and integrated into a microfluidic chip, including oocyte capture, sperm collection and isolation, sperm sorting, fertilization, and embryo culture. Ultimately, we summarize how microfluidics can complement and optimize current sperm sorting and IVF protocols, and challenges and possible solutions are discussed.
Collapse
Affiliation(s)
- Jingtong Ma
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China
| | - Qianlin Xie
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China
| | - Yusongjia Zhang
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China
| | - Qirui Xiao
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China
| | - Xiaoyu Liu
- Department of Obstetrics and Gynaecology, General Hospital of Northern Theater Command, Shenyang, 110003, China.
| | - Chong Qiao
- Department of Obstetrics and Gynecology of Shengjing Hospital of China Medical University, Shenyang, 110022, China.
- Key Laboratory of Maternal-Fetal Medicine of Liaoning Province, Shenyang, 110022, China.
| | - Ye Tian
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, 110169, China.
- Foshan Graduate School of Innovation, Northeastern University, Foshan, 528300, China.
| |
Collapse
|
3
|
Byeun DG, Kim D, Park JH, Lee M, Choi JK. Embryonic development through in vitro fertilization using high-quality bovine sperm separated in a biomimetic cervix environment. Analyst 2024; 149:3078-3084. [PMID: 38717228 DOI: 10.1039/d4an00166d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
This study is the first to identify bovine blastocysts through in vitro fertilization (IVF) of matured oocytes with a large quantity of high-quality sperm separated from a biomimetic cervix environment. We obtained high-quality sperm in large quantities using an IVF sperm sorting chip (SSC), which could mimic the viscous environment of the bovine cervix during ovulation and facilitates isolation of progressively motile sperm from semen. The viscous environment-on-a-chip was realized by formulating and implementing polyvinylpyrrolidone (PVP)-based solutions for the SSC medium. Sperm separated from the IVF-SSC containing PVP 1.5% showed high motility, normal morphology and high DNA integrity. As a result of IVF, a higher rate of hatching blastocysts, which is the pre-implantation stage, were observed, compared to the conventional swim-up method. Our results may significantly contribute to improving livestock with superior male and female genetic traits, thus overcoming the limitation of artificial insemination based on the superior genetic traits of existing males.
Collapse
Affiliation(s)
- Do Gyeung Byeun
- Department of Biotechnology, College of Life and Applied Sciences, Yeungnam University, Gyeongsan 38541, Korea.
| | - Dongwon Kim
- Department of Physics, Chungbuk National University, Cheongju 28644, Chungbuk, Korea.
| | - Jin Hee Park
- Department of Biotechnology, College of Life and Applied Sciences, Yeungnam University, Gyeongsan 38541, Korea.
| | - Manhee Lee
- Department of Physics, Chungbuk National University, Cheongju 28644, Chungbuk, Korea.
| | - Jung Kyu Choi
- Department of Biotechnology, College of Life and Applied Sciences, Yeungnam University, Gyeongsan 38541, Korea.
| |
Collapse
|
4
|
Nicholson TM, Tokihiro JC, Tu WC, Khor JW, Lee UN, Berthier E, Amory JK, Walsh TJ, Muller CH, Theberge AB. Open-Channel Droplet Microfluidic Platform for Passive Generation of Human Sperm Microdroplets. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.05.09.593416. [PMID: 38798664 PMCID: PMC11118337 DOI: 10.1101/2024.05.09.593416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Sperm cryopreservation is important for individuals undergoing infertility treatment, and for those who wish to preserve fertility potential, prior to treatments like chemotherapy, radiation therapy, gender-affirming medical interventions, elective fertility delay, or individuals in high-risk professions such as the military. Current methods for sperm cryopreservation result in approximately 30-50% decrease in sperm motility. However, recent studies have shown that ultra-rapid freezing (vitrification) is a valuable approach for maintaining sperm quality after freeze-thawing processes in the clinical laboratory setting and requires submicroliter to microliter volumes. A major challenge for the adoption of vitrification in fertility laboratories is the ability to pipette small volumes of sample. Here, we present a method that leverages open-channel droplet microfluidics to autonomously generate sub-microliter to microliter volumes of purified human sperm samples. Using a novel, open-channel droplet generator, we found no change in sperm movement and kinematic data after exposure to device and reagents in our platform. We conclude that our platform is compatible with human sperm, an important foundation for future implementation of vitrification in fertility laboratories.
Collapse
|
5
|
Bouloorchi Tabalvandani M, Saeidpour Z, Habibi Z, Javadizadeh S, Firoozabadi SA, Badieirostami M. Microfluidics as an emerging paradigm for assisted reproductive technology: A sperm separation perspective. Biomed Microdevices 2024; 26:23. [PMID: 38652182 DOI: 10.1007/s10544-024-00705-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/08/2024] [Indexed: 04/25/2024]
Abstract
Millions of people are subject to infertility worldwide and one in every six people, regardless of gender, experiences infertility at some period in their life, according to the World Health Organization. Assisted reproductive technologies are defined as a set of procedures that can address the infertility issue among couples, culminating in the alleviation of the condition. However, the costly conventional procedures of assisted reproduction and the inherent vagaries of the processes involved represent a setback for its successful implementation. Microfluidics, an emerging tool for processing low-volume samples, have recently started to play a role in infertility diagnosis and treatment. Given its host of benefits, including manipulating cells at the microscale, repeatability, automation, and superior biocompatibility, microfluidics have been adopted for various procedures in assisted reproduction, ranging from sperm sorting and analysis to more advanced processes such as IVF-on-a-chip. In this review, we try to adopt a more holistic approach and cover different uses of microfluidics for a variety of applications, specifically aimed at sperm separation and analysis. We present various sperm separation microfluidic techniques, categorized as natural and non-natural methods. A few of the recent developments in on-chip fertilization are also discussed.
Collapse
Affiliation(s)
| | - Zahra Saeidpour
- MEMS Lab, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 1439957131, Iran
| | - Zahra Habibi
- MEMS Lab, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 1439957131, Iran
| | - Saeed Javadizadeh
- MEMS Lab, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 1439957131, Iran
| | - Seyed Ahmadreza Firoozabadi
- MEMS Lab, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 1439957131, Iran
| | - Majid Badieirostami
- MEMS Lab, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 1439957131, Iran.
| |
Collapse
|
6
|
Wu T, Wu Y, Yan J, Zhang J, Wang S. Microfluidic chip as a promising evaluation method in assisted reproduction: A systematic review. Bioeng Transl Med 2024; 9:e10625. [PMID: 38435817 PMCID: PMC10905557 DOI: 10.1002/btm2.10625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 10/26/2023] [Accepted: 11/09/2023] [Indexed: 03/05/2024] Open
Abstract
The aim of assisted reproductive technology (ART) is to select the high-quality sperm, oocytes, and embryos, and finally achieve a successful pregnancy. However, functional evaluation is hindered by intra- and inter-operator variability. Microfluidic chips emerge as the one of the most powerful tools to analyze biological samples for reduced size, precise control, and flexible extension. Herein, a systematic search was conducted in PubMed, Scopus, Web of Science, ScienceDirect, and IEEE Xplore databases until March 2023. We displayed and prospected all detection strategies based on microfluidics in the ART field. After full-text screening, 71 studies were identified as eligible for inclusion. The percentages of human and mouse studies equaled with 31.5%. The prominent country in terms of publication number was the USA (n = 13). Polydimethylsiloxane (n = 49) and soft lithography (n = 28) were the most commonly used material and fabrication method, respectively. All articles were classified into three types: sperm (n = 38), oocytes (n = 20), and embryos (n = 13). The assessment contents included motility, counting, mechanics, permeability, impedance, secretion, oxygen consumption, and metabolism. Collectively, the microfluidic chip technology facilitates more efficient, accurate, and objective evaluation in ART. It can even be combined with artificial intelligence to assist the daily activities of embryologists. More well-designed clinical studies and affordable integrated microfluidic chips are needed to validate the safety, efficacy, and reproducibility. Trial registration: The protocol was registered in the Open Science Frame REGISTRIES (identification: osf.io/6rv4a).
Collapse
Affiliation(s)
- Tong Wu
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
| | - Yangyang Wu
- College of Animal Science and TechnologySichuan Agricultural UniversityYa'anSichuanChina
| | - Jinfeng Yan
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- School of Materials Science and EngineeringHuazhong University of Science and TechnologyWuhanChina
| | - Jinjin Zhang
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
| | - Shixuan Wang
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
| |
Collapse
|
7
|
Shukla SK, Gaudriault P, Corbera A. Lab-on-chip (LoC) application for quality sperm selection: An undelivered promise? OPEN RESEARCH EUROPE 2023; 3:188. [PMID: 38645796 PMCID: PMC11031645 DOI: 10.12688/openreseurope.16671.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 10/09/2023] [Indexed: 04/23/2024]
Abstract
Quality sperm selection is essential to ensure the effectiveness of assisted reproductive techniques (ART). However, the methods employed for sperm selection in ART often yield suboptimal outcomes, contributing to lower success rates. In recent years, microfluidic devices have emerged as a promising avenue for investigating the natural swimming behavior of spermatozoa and developing innovative approaches for quality sperm selection. Despite their potential, the commercial translation of microfluidic-based technologies has remained limited. This comprehensive review aims to critically evaluate the inherent potential of lab-on-chip technology in unraveling sophisticated mechanisms encompassing rheotaxis, thermotaxis, and chemotaxis. By reviewing the current state-of-the-art associated with microfluidic engineering and the swimming of spermatozoa, the goal is to shed light on the multifaceted factors that have impeded the broader commercialization of these cutting-edge technologies and recommend a commercial that can surmount the prevailing constraints. Furthermore, this scholarly exploration seeks to enlighten and actively engage reproductive clinicians in the profound potential and implications of microfluidic methodologies within the context of human infertility.
Collapse
Affiliation(s)
- Shiva K Shukla
- Research and Development Unit, Beez Biotech SAS, RENNES, Ille-et-Villain, 35000, France
| | - Pierre Gaudriault
- Research and Development Unit, Cherry Biotech SAS, Paris, 93100, France
| | - Antoni Corbera
- Research and Development Unit, Cherry Biotech SAS, Paris, 93100, France
| |
Collapse
|
8
|
Ferraz MDAMM, Ferronato GDA. Opportunities involving microfluidics and 3D culture systems to the in vitro embryo production. Anim Reprod 2023; 20:e20230058. [PMID: 37638255 PMCID: PMC10449241 DOI: 10.1590/1984-3143-ar2023-0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 06/29/2023] [Indexed: 08/29/2023] Open
Abstract
Traditional methods of gamete handling, fertilization, and embryo culture often face limitations in efficiency, consistency, and the ability to closely mimic in vivo conditions. This review explores the opportunities presented by microfluidic and 3D culture systems in overcoming these challenges and enhancing in vitro embryo production. We discuss the basic principles of microfluidics, emphasizing their inherent advantages such as precise control of fluid flow, reduced reagent consumption, and high-throughput capabilities. Furthermore, we delve into microfluidic devices designed for gamete manipulation, in vitro fertilization, and embryo culture, highlighting innovations such as droplet-based microfluidics and on-chip monitoring. Next, we explore the integration of 3D culture systems, including the use of biomimetic scaffolds and organ-on-a-chip platforms, with a particular focus on the oviduct-on-a-chip. Finally, we discuss the potential of these advanced systems to improve embryo production outcomes and advance our understanding of early embryo development. By leveraging the unique capabilities of microfluidics and 3D culture systems, we foresee significant advancements in the efficiency, effectiveness, and clinical success of in vitro embryo production.
Collapse
Affiliation(s)
- Marcia de Almeida Monteiro Melo Ferraz
- Faculty of Veterinary Medicine, Ludwig-Maximilians University of Munich, Oberschleißheim, Germany
- Gene Center, Ludwig-Maximilians University of Munich, Munich, Germany
| | - Giuliana de Avila Ferronato
- Faculty of Veterinary Medicine, Ludwig-Maximilians University of Munich, Oberschleißheim, Germany
- Gene Center, Ludwig-Maximilians University of Munich, Munich, Germany
| |
Collapse
|
9
|
Huang J, Chen H, Li N, Zhao Y. Emerging microfluidic technologies for sperm sorting. ENGINEERED REGENERATION 2023. [DOI: 10.1016/j.engreg.2023.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023] Open
|
10
|
Sood A, Kumar A, Gupta VK, Kim CM, Han SS. Translational Nanomedicines Across Human Reproductive Organs Modeling on Microfluidic Chips: State-of-the-Art and Future Prospects. ACS Biomater Sci Eng 2023; 9:62-84. [PMID: 36541361 DOI: 10.1021/acsbiomaterials.2c01080] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Forecasting the consequence of nanoparticles (NPs) and therapeutically significant molecules before materializing for human clinical trials is a mainstay for drug delivery and screening processes. One of the noteworthy obstacles that has prevented the clinical translation of NP-based drug delivery systems and novel drugs is the lack of effective preclinical platforms. As a revolutionary technology, the organ-on-a-chip (OOC), a coalition of microfluidics and tissue engineering, has surfaced as an alternative to orthodox screening platforms. OOC technology recapitulates the structural and physiological features of human organs along with intercommunications between tissues on a chip. The current review discusses the concept of microfluidics and confers cutting-edge fabrication processes for chip designing. We also outlined the advantages of microfluidics in analyzing NPs in terms of characterization, transport, and degradation in biological systems. The review further elaborates the scope and research on translational nanomedicines in human reproductive organs (testis, placenta, uterus, and menstrual cycle) by taking the advantages offered by microfluidics and shedding light on their potential future implications. Finally, we accentuate the existing challenges for clinical translation and scale-up dynamics for microfluidics chips and emphasize its future perspectives.
Collapse
Affiliation(s)
- Ankur Sood
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, South Korea
| | - Anuj Kumar
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, South Korea.,Institute of Cell Culture, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, South Korea
| | - Vijai Kumar Gupta
- Biorefining and Advanced Materials Research Center, Scotland's Rural College, Edinburgh EH9 3JG, United Kingdom
| | - Chul Min Kim
- Department of Mechatronics Engineering, Gyeongsang National University, 33 Dongjin-ro, Jinju, Gyeongsangnam-do 52725, South Korea
| | - Sung Soo Han
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, South Korea.,Institute of Cell Culture, Yeungnam University, 280 Daehak-ro, Gyeongsan 38541, South Korea
| |
Collapse
|
11
|
Shi H, Xie Z, Cao Y, Zhao Y, Zhang C, Chen Z, Reis NM, Liu Z. A microfluidic serial dilutor (MSD): Design optimization and application to tuning of liposome nanoparticle preparation. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.118080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
12
|
Chen C, Li P, Guo T, Chen S, Xu D, Chen H. Generation of Dynamic Concentration Profile Using A Microfluidic Device Integrating Pneumatic Microvalves. BIOSENSORS 2022; 12:bios12100868. [PMID: 36291005 PMCID: PMC9599525 DOI: 10.3390/bios12100868] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/08/2022] [Accepted: 10/09/2022] [Indexed: 06/12/2023]
Abstract
Generating and maintaining the concentration dilutions of diffusible molecules in microchannels is critical for high-throughput chemical and biological analysis. Conventional serial network microfluidic technologies can generate high orders of arbitrary concentrations by a predefined microchannel network. However, a previous design requires a large occupancy area and is unable to dynamically generate different profiles in the same chip, limiting its applications. This study developed a microfluidic device enabling dynamic variations of both the concentration in the same channel and the concentration distribution in multiple channels by adjusting the flow resistance using programmable pneumatic microvalves. The key component (the pneumatic microvalve) allowed dynamic adjustment of the concentration profile but occupied a tiny space. Additionally, a Matlab program was developed to calculate the flow rates and flow resistance of various sections of the device, which provided theoretical guidance for dimension design. In silico investigations were conducted to evaluate the microvalve deformation with widths from 100 to 300 µm and membrane thicknesses of 20 and 30 µm under the activation pressures between 0 and 2000 mbar. The flow resistance of the deformed valve was studied both numerically and experimentally and an empirical model for valve flow resistance with the form of Rh=aebP was proposed. Afterward, the fluid flow in the valve region was characterized using Micro PIV to further demonstrate the adjustment mechanism of the flow resistance. Then, the herringbone structures were employed for fast mixing to allow both quick variation of concentration and minor space usage of the channel network. Finally, an empirical formula-supported computational program was developed to provide the activation pressures required for the specific concentration profile. Both linear (Ck = -0.2k + 1) and nonlinear (Ck = (110)k) concentration distribution in four channels were varied using the same device by adjusting microvalves. The device demonstrated the capability to control the concentration profile dynamically in a small space, offering superior application potentials in analytical chemistry, drug screening, and cell biology research.
Collapse
Affiliation(s)
- Chang Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China
| | - Panpan Li
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW 2052, Australia
| | - Siyuan Chen
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
| | - Dong Xu
- School of Science, Harbin Institute of Technology, Shenzhen 518055, China
| | - Huaying Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen 518055, China
| |
Collapse
|
13
|
Label-Free Microfluidic Impedance Cytometry for Acrosome Integrity Assessment of Boar Spermatozoa. BIOSENSORS 2022; 12:bios12090679. [PMID: 36140064 PMCID: PMC9496365 DOI: 10.3390/bios12090679] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/15/2022] [Accepted: 08/22/2022] [Indexed: 11/17/2022]
Abstract
Microfluidics and lab-on-chip technologies have been used in a wide range of biomedical applications. They are known as versatile, rapid, and low-cost alternatives for expensive equipment and time-intensive processing. The veterinary industry and human fertility clinics could greatly benefit from label-free and standardized methods for semen analysis. We developed a tool to determine the acrosome integrity of spermatozoa using microfluidic impedance cytometry. Spermatozoa from boars were treated with the calcium ionophore A23187 to induce acrosome reaction. The magnitude, phase and opacity of individual treated and non-treated (control) spermatozoa were analyzed and compared to conventional staining for acrosome integrity. The results show that the opacity at 19 MHz over 0.5 MHz is associated with acrosome integrity with a cut-off threshold at 0.86 (sensitivity 98%, specificity 97%). In short, we have demonstrated that acrosome integrity can be determined using opacity, illustrating that microfluidic impedance cytometers have the potential to become a versatile and efficient alternative in semen analysis and for fertility treatments in the veterinary industry and human fertility clinics.
Collapse
|
14
|
Dehghanpour F, khalili MA, Mangoli E, Talebi AR, Anbari F, Shamsi F, Woodward B, Doostabadi MR. Free centrifuge sorting method for high‐count sperm preparation improves biological characteristics of human spermatozoa and clinical outcome: A sibling oocytes study. Andrologia 2022; 54:e14554. [DOI: 10.1111/and.14554] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Revised: 07/13/2022] [Accepted: 07/27/2022] [Indexed: 12/17/2022] Open
Affiliation(s)
- Fatemeh Dehghanpour
- Research and Clinical Center for Infertility Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences Yazd Iran
- Department of Reproductive Biology Shahid Sadoughi University of Medical Sciences Yazd Iran
| | - Mohammad Ali khalili
- Research and Clinical Center for Infertility Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences Yazd Iran
- Department of Reproductive Biology Shahid Sadoughi University of Medical Sciences Yazd Iran
| | - Esmat Mangoli
- Research and Clinical Center for Infertility Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences Yazd Iran
- Department of Reproductive Biology Shahid Sadoughi University of Medical Sciences Yazd Iran
| | - Ali Reza Talebi
- Department of Reproductive Biology Shahid Sadoughi University of Medical Sciences Yazd Iran
- Andrology Research center Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences Yazd Iran
| | - Fatemeh Anbari
- Research and Clinical Center for Infertility Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences Yazd Iran
- Department of Reproductive Biology Shahid Sadoughi University of Medical Sciences Yazd Iran
| | - Farimah Shamsi
- Department of Biostatistics and Epidemiology School of public health Shahid Sadoughi University of Medical Sciences Yazd Iran
| | | | - Mohamad Reza Doostabadi
- Research and Clinical Center for Infertility Yazd Reproductive Sciences Institute, Shahid Sadoughi University of Medical Sciences Yazd Iran
| |
Collapse
|
15
|
Olatunji O, More A. A Review of the Impact of Microfluidics Technology on Sperm Selection Technique. Cureus 2022; 14:e27369. [PMID: 36046322 PMCID: PMC9419845 DOI: 10.7759/cureus.27369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 07/27/2022] [Indexed: 11/26/2022] Open
Abstract
Sperm sorting procedures depend on centrifugation processes. These processes produce oxidative stress and cell damage that are undesirable for in-vitro fertilization/intracytoplasmic sperm injection (IVF/ICSI) outcomes because they affect fertilization and implantation chances. The microfluidic sperm selection technique has shown promise in this area. It can create a platform for isolating and manipulating good-quality sperm cells using diverse triggers such as mechanical factors, chemical agents, and temperature gradients. Furthermore, microfluidic platforms can direct sperm cells for IVF or sperm sorting by utilizing an approach that is passive or active. In this review, we explain the use of microfluidics technologies for sorting and arranging sperm cells for different purposes. We also discuss the use of microfluidics technology in selecting and assessing sperm parameters and how it affects male infertility.
Collapse
|
16
|
Penny JA, Lymbery RA, Evans JP, Sherman CDH, Conlan XA. The use of microfluidic devices in studies of differential sperm chemotaxis. Trends Biotechnol 2022; 40:1144-1147. [PMID: 35902284 DOI: 10.1016/j.tibtech.2022.06.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 06/22/2022] [Accepted: 06/30/2022] [Indexed: 10/16/2022]
Abstract
Differential sperm chemotaxis describes differences among male-female pairings in chemotactic responses of sperm to egg (or female)-derived chemical attractants. Microfluidic devices provide powerful platforms in which to study this complex gamete interaction. Here, we describe key challenges and potential solutions in applying this state-of-the-art technique to differential sperm chemotaxis.
Collapse
Affiliation(s)
- Jake A Penny
- Deakin University, School of Life and Environmental Sciences, Geelong, Victoria 3216, Australia.
| | - Rowan A Lymbery
- School of Biological Sciences, The University of Western Australia, Crawley, WA 6009, Australia
| | - Jonathan P Evans
- School of Biological Sciences, The University of Western Australia, Crawley, WA 6009, Australia
| | - Craig D H Sherman
- Deakin University, School of Life and Environmental Sciences, Geelong, Victoria 3216, Australia
| | - Xavier A Conlan
- Deakin University, School of Life and Environmental Sciences, Geelong, Victoria 3216, Australia
| |
Collapse
|
17
|
Choi Y, Sunkara V, Lee Y, Cho YK. Exhausted mature dendritic cells exhibit a slower and less persistent random motility but retain chemotaxis against CCL19. LAB ON A CHIP 2022; 22:377-386. [PMID: 34927189 DOI: 10.1039/d1lc00876e] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Dendritic cells (DCs), which are immune sentinels in the peripheral tissues, play a number of roles, including patrolling for pathogens, internalising antigens, transporting antigens to the lymph nodes (LNs), interacting with T cells, and secreting cytokines. The well-coordinated migration of DCs under various immunological or inflammatory conditions is therefore essential to ensure an effective immune response. Upon maturation, DCs migrate faster and more persistently than immature DCs (iDCs), which is believed to facilitate CCR7-dependent chemotaxis. It has been reported that lipopolysaccharide-activated DCs produce IL-12 only transiently, and become resistant to further stimulation through exhaustion. However, little is known about the influence of DC exhaustion on cellular motility. Here, we studied the cellular migration of exhausted DCs in tissue-mimicked confined environments. We found that the speed of exhausted matured DCs (xmDCs) decreased significantly compared to active matured DCs (amDCs) and iDCs. In contrast, the speed fluctuation increased compared to that of amDCs and was similar to that of iDCs. In addition, the diffusivity of the xmDCs was significantly lower than that of the amDCs, which implies that DC exhaustion reduces the space exploration ability. Interestingly, CCR7-dependent chemotaxis against CCL19 in xmDCs was not considerably different from that observed in amDCs. Taken together, we report a unique intrinsic cell migration behaviour of xmDCs, which exhibit a slower, less persistent, and less diffusive random motility, which results in the DCs remaining at the site of infection, although a well-preserved CCR7-dependent chemotactic motility is maintained.
Collapse
Affiliation(s)
- Yongjun Choi
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan 44919, Republic of Korea
| | - Vijaya Sunkara
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan 44919, Republic of Korea
| | - Yeojin Lee
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan 44919, Republic of Korea
| | - Yoon-Kyoung Cho
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan 44919, Republic of Korea
| |
Collapse
|
18
|
Ahmadkhani N, Hosseini M, Saadatmand M, Abbaspourrad A. The influence of the female reproductive tract and sperm features on the design of microfluidic sperm-sorting devices. J Assist Reprod Genet 2022; 39:19-36. [PMID: 35034216 PMCID: PMC8866594 DOI: 10.1007/s10815-021-02377-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 12/06/2021] [Indexed: 01/03/2023] Open
Abstract
Although medical advancements have successfully helped a lot of couples with their infertility by assisted reproductive technologies (ART), sperm selection, a crucial stage in ART, has remained challenging. Therefore, we aimed to investigate novel sperm separation methods, specifically microfluidic systems, as they do sperm selection based on sperm and/or the female reproductive tract (FRT) features without inflicting any damage to the selected sperm during the process. In this review, after an exhaustive studying of FRT features, which can implement by microfluidics devices, the focus was centered on sperm selection and investigation devices. During this study, we tried not to only point to the deficiencies of these systems, but to put forth suggestions for their improvement as well.
Collapse
Affiliation(s)
- Nima Ahmadkhani
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Mahshid Hosseini
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Maryam Saadatmand
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran.
| | - Alireza Abbaspourrad
- Department of Food Science, College of Agriculture and Life Sciences, Cornell University, Ithaca, NY, 14853, USA
| |
Collapse
|
19
|
Keyser S, van der Horst G, Maree L. Progesterone, Myo-Inositol, Dopamine and Prolactin Present in Follicular Fluid Have Differential Effects on Sperm Motility Subpopulations. Life (Basel) 2021; 11:1250. [PMID: 34833125 PMCID: PMC8617736 DOI: 10.3390/life11111250] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/09/2021] [Accepted: 11/11/2021] [Indexed: 12/14/2022] Open
Abstract
Considering the challenges surrounding causative factors in male infertility, rather than relying on standard semen analysis, the assessment of sperm subpopulations and functional characteristics essential for fertilization is paramount. Furthermore, the diagnostic value of sperm interactions with biological components in the female reproductive tract may improve our understanding of subfertility and provide applications in assisted reproductive techniques. We investigated the response of two sperm motility subpopulations (mimicking the functionality of potentially fertile and sub-fertile semen samples) to biological substances present in the female reproductive tract. Donor semen was separated via double density gradient centrifugation, isolated into high (HM) and low motile (LM) sperm subpopulations and incubated in human tubal fluid (HTF), capacitating HTF, HD-C medium, progesterone, myo-inositol, dopamine and prolactin. Treated subpopulations were evaluated for vitality, motility percentages and kinematic parameters, hyperactivation, positive reactive oxygen species (ROS), intact mitochondrial membrane potential (MMP) and acrosome reaction (AR). While all media had a significantly positive effect on the LM subpopulation, dopamine appeared to significantly improve both subpopulations' functional characteristics. HD-C, progesterone and myo-inositol resulted in increased motility, kinematic and hyperactivation parameters, whereas prolactin and myo-inositol improved the LM subpopulations' MMP intactness and reduced ROS. Furthermore, progesterone, myo-inositol and dopamine improved the HM subpopulations' motility parameters and AR. Our results suggest that treatment of sub-fertile semen samples with biological substances present in follicular fluid might assist the development of new strategies for IVF treatment.
Collapse
Affiliation(s)
| | | | - Liana Maree
- Comparative Spermatology Laboratory, Department of Medical Bioscience, Faculty of Natural Sciences, University of the Western Cape, Private Bag X17, Bellville 7535, South Africa; (S.K.); (G.v.d.H.)
| |
Collapse
|
20
|
Simchi M, Riordon J, You JB, Wang Y, Xiao S, Lagunov A, Hannam T, Jarvi K, Nosrati R, Sinton D. Selection of high-quality sperm with thousands of parallel channels. LAB ON A CHIP 2021; 21:2464-2475. [PMID: 33982043 DOI: 10.1039/d0lc01182g] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Sperm selection is essential for successful fertilization and embryo development. Current clinical sperm selection methods are labor-intensive and lack the selectivity required to isolate high-quality sperm. Microfluidic sperm selection approaches have shown promise but present a trade-off between the quality and quantity of selected sperm - clinicians demand both. The structure of the female reproductive tract helps to isolate a sufficient quantity of high-quality sperm for fertilization with densely folded epithelium that provides a multitude of longitudinally oriented pathways that guide sperm toward the fertilization site. Here, a three-dimensionally structured sperm selection device is presented that levers this highly parallelized in vivo mechanism for in vitro sperm selection. The device is inserted in a test tube atop 1 mL of raw semen and provides 6500 channels that isolate ∼100 000 high-DNA-integrity sperm for assisted reproduction. In side-by-side clinical testing, the developed approach outperforms the best current clinical methods by improving the DNA integrity of the selected sperm subpopulation up to 95%. Also, the device streamlines clinical workflow, reducing the time required for sperm preparation 3-fold. This single-tube, single-step sperm preparation approach promises to improve both the economics and outcomes of assisted reproduction practices, especially in cases with significant male-factors.
Collapse
Affiliation(s)
- Mohammad Simchi
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S 3G8, Canada.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Khan A, Smith NM, Tullier MP, Roberts BS, Englert D, Pojman JA, Melvin AT. Development of a Flow-free Gradient Generator Using a Self-Adhesive Thiol-acrylate Microfluidic Resin/Hydrogel (TAMR/H) Hybrid System. ACS APPLIED MATERIALS & INTERFACES 2021; 13:26735-26747. [PMID: 34081856 PMCID: PMC8289190 DOI: 10.1021/acsami.1c04771] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Accepted: 05/21/2021] [Indexed: 06/12/2023]
Abstract
Microfluidic gradient generators have been used to study cellular migration, growth, and drug response in numerous biological systems. One type of device combines a hydrogel and polydimethylsiloxane (PDMS) to generate "flow-free" gradients; however, their requirements for either negative flow or external clamps to maintain fluid-tight seals between the two layers have restricted their utility among broader applications. In this work, a two-layer, flow-free microfluidic gradient generator was developed using thiol-ene chemistry. Both rigid thiol-acrylate microfluidic resin (TAMR) and diffusive thiol-acrylate hydrogel (H) layers were synthesized from commercially available monomers at room temperature and pressure using a base-catalyzed Michael addition. The device consisted of three parallel microfluidic channels negatively imprinted in TAMR layered on top of the thiol-acrylate hydrogel to facilitate orthogonal diffusion of chemicals to the direction of flow. Upon contact, these two layers formed fluid-tight channels without any external pressure due to a strong adhesive interaction between the two layers. The diffusion of molecules through the TAMR/H system was confirmed both experimentally (using fluorescent microscopy) and computationally (using COMSOL). The performance of the TAMR/H system was compared to a conventional PDMS/agarose device with a similar geometry by studying the chemorepulsive response of a motile strain of GFP-expressing Escherichia coli. Population-based analysis confirmed a similar migratory response of both wild-type and mutant E. coli in both of the microfluidic devices. This confirmed that the TAMR/H hybrid system is a viable alternative to traditional PDMS-based microfluidic gradient generators and can be used for several different applications.
Collapse
Affiliation(s)
- Anowar
H. Khan
- Department
of Chemistry, Louisiana State University, Baton Rouge 70803, Louisiana, United States
| | - Noah Mulherin Smith
- Cain
Department of Chemical Engineering, Louisiana
State University, Baton Rouge 70803, Louisiana, United States
| | - Michael P. Tullier
- Department
of Chemistry, Louisiana State University, Baton Rouge 70803, Louisiana, United States
| | - B. Seth Roberts
- Cain
Department of Chemical Engineering, Louisiana
State University, Baton Rouge 70803, Louisiana, United States
| | - Derek Englert
- Chemical
and Materials Engineering, University of
Kentucky, Paducah 42002, Kentucky, United States
| | - John A. Pojman
- Department
of Chemistry, Louisiana State University, Baton Rouge 70803, Louisiana, United States
| | - Adam T. Melvin
- Cain
Department of Chemical Engineering, Louisiana
State University, Baton Rouge 70803, Louisiana, United States
| |
Collapse
|
22
|
Abstract
Sperm selection is a clinical need for guided fertilization in men with low-quality semen. In this regard, microfluidics can provide an enabling platform for the precise manipulation and separation of high-quality sperm cells through applying various stimuli, including chemical agents, mechanical forces, and thermal gradients. In addition, microfluidic platforms can help to guide sperms and oocytes for controlled in vitro fertilization or sperm sorting using both passive and active methods. Herein, we present a detailed review of the use of various microfluidic methods for sorting and categorizing sperms for different applications. The advantages and disadvantages of each method are further discussed and future perspectives in the field are given.
Collapse
|
23
|
Ramal-Sanchez M, Bernabò N, Valbonetti L, Cimini C, Taraschi A, Capacchietti G, Machado-Simoes J, Barboni B. Role and Modulation of TRPV1 in Mammalian Spermatozoa: An Updated Review. Int J Mol Sci 2021; 22:4306. [PMID: 33919147 PMCID: PMC8122410 DOI: 10.3390/ijms22094306] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/19/2021] [Accepted: 04/19/2021] [Indexed: 12/26/2022] Open
Abstract
Based on the abundance of scientific publications, the polymodal sensor TRPV1 is known as one of the most studied proteins within the TRP channel family. This receptor has been found in numerous cell types from different species as well as in spermatozoa. The present review is focused on analyzing the role played by this important channel in the post-ejaculatory life of spermatozoa, where it has been described to be involved in events such as capacitation, acrosome reaction, calcium trafficking, sperm migration, and fertilization. By performing an exhaustive bibliographic search, this review gathers, for the first time, all the modulators of the TRPV1 function that, to our knowledge, were described to date in different species and cell types. Moreover, all those modulators with a relationship with the reproductive process, either found in the female tract, seminal plasma, or spermatozoa, are presented here. Since the sperm migration through the female reproductive tract is one of the most intriguing and less understood events of the fertilization process, in the present work, chemotaxis, thermotaxis, and rheotaxis guiding mechanisms and their relationship with TRPV1 receptor are deeply analyzed, hypothesizing its (in)direct participation during the sperm migration. Last, TRPV1 is presented as a pharmacological target, with a special focus on humans and some pathologies in mammals strictly related to the male reproductive system.
Collapse
Affiliation(s)
- Marina Ramal-Sanchez
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
| | - Nicola Bernabò
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
- Institute of Biochemistry and Cell Biology (CNR-IBBC/EMMA/Infrafrontier/IMPC), National Research Council, Monterotondo Scalo, 00015 Rome, Italy
| | - Luca Valbonetti
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
- Institute of Biochemistry and Cell Biology (CNR-IBBC/EMMA/Infrafrontier/IMPC), National Research Council, Monterotondo Scalo, 00015 Rome, Italy
| | - Costanza Cimini
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
| | - Angela Taraschi
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
- Istituto Zooprofilattico Sperimentale dell’Abruzzo e del Molise “G. Caporale”, Via Campo Boario 1, 64100 Teramo, Italy
| | - Giulia Capacchietti
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
| | - Juliana Machado-Simoes
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
| | - Barbara Barboni
- Faculty of Biosciences and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy; (N.B.); (L.V.); (C.C.); (A.T.); (G.C.); (J.M.-S.); (B.B.)
| |
Collapse
|
24
|
Yan Y, Zhang B, Fu Q, Wu J, Liu R. A fully integrated biomimetic microfluidic device for evaluation of sperm response to thermotaxis and chemotaxis. LAB ON A CHIP 2021; 21:310-318. [PMID: 33444427 DOI: 10.1039/d0lc00845a] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
In recent decades, humans have faced greater challenges in reproduction. Assisted reproductive technology is the most prominent approach for addressing this problem. Current clinical screening methods simply consider the motility or morphology of the sperm. However, as the spermatozoa need to navigate over a long distance in the female reproductive tract and survive the natural screening processes therein, these methods are imperfect. Many approaches have been undertaken to study the chemotaxis and thermotaxis navigation behavior of spermatozoa, but few of these have involved integrated screening that considers motility, chemotaxis, and thermotaxis based on the biological environment of the human body. Current routine sperm evaluation techniques are inadequate and fail to simultaneously provide conclusive evidence for the thermotactic and chemotactic characteristics of sperm. Thus, such screening of functional spermatozoa will be an advancement in assisted reproduction. In this study, we developed a fully integrated biomimetic microfluidic system for screening sperm for their characteristics when exposed to temperature and chemical gradients. Based on our results, we showed that spermatozoa were attracted by temperature and chemical gradients in the physiological range. Moreover, we ascertained a suitable temperature gradient range for thermotaxis and statistically proved that the thermotactic and chemotactic responses are not linked. Here, we report the first quantitative study of functional sperm during thermotaxis and chemotaxis, and our analysis of the difference in motility caused by different conditions. More broadly, we foresee the clinical application of these biologically motivated parameters and characteristics in assisted reproduction in humans.
Collapse
Affiliation(s)
- Yimo Yan
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084 China.
| | | | | | | | | |
Collapse
|
25
|
Wheeler ML, Oyen ML. Bioengineering Approaches for Placental Research. Ann Biomed Eng 2021; 49:1805-1818. [PMID: 33420547 DOI: 10.1007/s10439-020-02714-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Accepted: 12/23/2020] [Indexed: 12/11/2022]
Abstract
Research into the human placenta's complex functioning is complicated by a lack of suitable physiological in vivo models. Two complementary approaches have emerged recently to address these gaps in understanding, computational in silico techniques, including multi-scale modeling of placental blood flow and oxygen transport, and cellular in vitro approaches, including organoids, tissue engineering, and organ-on-a-chip models. Following a brief introduction to the placenta's structure and function and its influence on the substantial clinical problem of preterm birth, these different bioengineering approaches are reviewed. The cellular techniques allow for investigation of early first-trimester implantation and placental development, including critical biological processes such as trophoblast invasion and trophoblast fusion, that are otherwise very difficult to study. Similarly, computational models of the placenta and the pregnant pelvis at later-term gestation allow for investigations relevant to complications that occur when the placenta has fully developed. To fully understand clinical conditions associated with the placenta, including those with roots in early processes but that only manifest clinically at full-term, a holistic approach to the study of this fascinating, temporary but critical organ is required.
Collapse
Affiliation(s)
- Mackenzie L Wheeler
- Department of Engineering, East Carolina University, Greenville, NC, 27834, USA
| | - Michelle L Oyen
- Department of Engineering, East Carolina University, Greenville, NC, 27834, USA.
| |
Collapse
|
26
|
Kumar N, Singh AK. The anatomy, movement, and functions of human sperm tail: an evolving mystery. Biol Reprod 2020; 104:508-520. [PMID: 33238303 DOI: 10.1093/biolre/ioaa213] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 11/16/2020] [Accepted: 11/20/2020] [Indexed: 12/15/2022] Open
Abstract
Sperms have attracted attention of many researchers since it was discovered by Antonie van Leeuwenhoek in 1677. Though a small cell, its every part has complex structure and different function to play in carrying life. Sperm tail is most complicated structure with more than 1000 proteins involved in its functioning. With the advent of three-dimensional microscopes, many studies are undergoing to understand exact mechanism of sperm tail movement. Most recent studies have shown that sperms move by spinning rather than swimming. Each subunit of tail, including axonemal, peri-axonemal structures, plays essential roles in sperm motility, capacitation, hyperactivation, fertilization. Furthermore, over 2300 genes are involved in spermatogenesis. A number of genetic mutations have been linked with abnormal sperm flagellar development leading to motility defects and male infertility. It was found that 6% of male infertility cases are related to genetic causes, and 4% of couples undergoing intracytoplasmic sperm injection for male subfertility have chromosomal abnormalities. Hence, an understanding of sperm tail development and genes associated with its normal functioning can help in better diagnosis of male infertility and its management. There is still a lot that needs to be discovered about genes, proteins contributing to normal human sperm tail development, movement, and role in male fertility. Sperm tail has complex anatomy, with surrounding axoneme having 9 + 2 microtubules arrangement along its entire length and peri-axonemal structures that contribute in sperm motility and fertilization. In future sperm tail-associated genes, proteins and subunits can be used as markers of male fertility.
Collapse
Affiliation(s)
- Naina Kumar
- Department of Obstetrics and Gynecology, All India Institute of Medical Sciences, Guntur, Andhra Pradesh 522503, India
| | - Amit Kant Singh
- Department of Physiology, U.P. University of Medical Sciences, Etawah 206130, Uttar Pradesh, India
| |
Collapse
|
27
|
Jeong HH. Recent Developments in Bacterial Chemotaxis Analysis Based on the Microfluidic System. SLAS Technol 2020; 26:159-164. [PMID: 33143544 DOI: 10.1177/2472630320969146] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Bacterial motility in response to chemicals, also called bacterial chemotaxis, is a critical ability to search for the optimal environment to ensure the survival of bacterial species. Recent advances in microbiology have allowed the engineering of bacterial chemotactic properties. Conventional methods for characterizing bacterial motility are not able to fully monitor chemotactic behavior. Developments in microfluidic technology have enabled the designing of new experimental protocols in which spatiotemporal control of the cellular microenvironment can be achieved, and in which bacterial motility can be precisely and quantitatively measured and compared. This review provides an overview of recent developments of and new insights into microfluidic systems for chemotaxis assay.
Collapse
Affiliation(s)
- Heon-Ho Jeong
- Department of Chemical and Biomolecular Engineering, Chonnam National University, Yeosu, Jeonnam, Republic of Korea
| |
Collapse
|
28
|
Le Gac S, Ferraz M, Venzac B, Comizzoli P. Understanding and Assisting Reproduction in Wildlife Species Using Microfluidics. Trends Biotechnol 2020; 39:584-597. [PMID: 33039163 DOI: 10.1016/j.tibtech.2020.08.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 08/30/2020] [Accepted: 08/31/2020] [Indexed: 12/31/2022]
Abstract
Conservation breeding and assisted reproductive technologies (ARTs) are invaluable tools to save wild animal species that are on the brink of extinction. Microfluidic devices recently developed for human or domestic animal reproductive medicine could significantly help to increase knowledge about fertility and contribute to the success of ART in wildlife. Some of these microfluidic tools could be applied to wild species, but dedicated efforts will be necessary to meet specific needs in animal conservation; for example, they need to be cost-effective, applicable to multiple species, and field-friendly. Microfluidics represents only one powerful technology in a complex toolbox and must be integrated with other approaches to be impactful in managing wildlife reproduction.
Collapse
Affiliation(s)
- Séverine Le Gac
- Applied Microfluidics for BioEngineering Research, Faculty of Electrical Engineering, Mathematics and Computer Sciences, MESA+ Institute for Nanotechnology, and TechMed Center, University of Twente, Enschede, The Netherlands.
| | - Marcia Ferraz
- Department of Veterinary Sciences, Ludwig-Maximilians University of Munich, Munich, Germany
| | - Bastien Venzac
- Applied Microfluidics for BioEngineering Research, Faculty of Electrical Engineering, Mathematics and Computer Sciences, MESA+ Institute for Nanotechnology, and TechMed Center, University of Twente, Enschede, The Netherlands
| | - Pierre Comizzoli
- Smithsonian Conservation Biology Institute, National Zoological Park, Washington, DC, USA.
| |
Collapse
|
29
|
Yan Y, Liu H, Zhang B, Liu R. A PMMA-Based Microfluidic Device for Human Sperm Evaluation and Screening on Swimming Capability and Swimming Persistence. MICROMACHINES 2020; 11:mi11090793. [PMID: 32839382 PMCID: PMC7570091 DOI: 10.3390/mi11090793] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/11/2020] [Accepted: 08/17/2020] [Indexed: 11/24/2022]
Abstract
The selection of high-quality sperm is essential to the success of in vitro fertilization (IVF). As human cervical mucus has a high viscosity, without enough swimming persistence, human sperm clouds cannot arrive at the ampulla to fertilize the egg. In this study, we used swimming capability and motion characteristics that are known to be associated with fertilization ability to evaluate the quality of sperm. Here, a clinically applicable polymethyl methacrylate (PMMA)-based microdevice was designed and fabricated for sperm evaluation and screening for swimming capability and persistence in a viscous environment. In this study, we applied methylcellulose (MC) to mimic the natural properties of mucus in vivo to achieve the selection of motile sperm. Sperm motion was recorded by an inverted microscope. The statistical features were extracted and analyzed. Hundreds of sperm in two treated groups with different concentrations of MC and one control group with human tubal fluid (HTF) media were video recorded. This device can achieve a one-step procedure of high-quality sperm selection and achieve the quantitative evaluation of sperm swimming capability and persistence. Sperm with good swimming capability and persistence may be more suitable for fertilization in a viscous environment. This microdevice and methods could be used to guide the evaluation of sperm motility and screening in the future.
Collapse
Affiliation(s)
- Yimo Yan
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Y.Y.); (H.L.); (B.Z.)
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Haoran Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Y.Y.); (H.L.); (B.Z.)
| | - Boxuan Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China; (Y.Y.); (H.L.); (B.Z.)
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Ran Liu
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
- Correspondence:
| |
Collapse
|
30
|
Meitei HY, Uppangala S, Sharan K, Chandraguthi SG, Radhakrishnan A, Kalthur G, Schlatt S, Adiga SK. A Simple, Centrifugation-Free, Sperm-Sorting Device Eliminates the Risks of Centrifugation in the Swim-Up Method While Maintaining Functional Competence and DNA Integrity of Selected Spermatozoa. Reprod Sci 2020; 28:134-143. [PMID: 32734563 PMCID: PMC7782414 DOI: 10.1007/s43032-020-00269-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 07/22/2020] [Indexed: 12/22/2022]
Abstract
This pilot study was conducted to explore the benefits of using a centrifugation-free device based on the migration–sedimentation (MS) technique over centrifugation-based techniques in selecting competent spermatozoa, as compared with using split human semen samples. Ejaculates from 35 men undergoing semen analysis were split into four parts where one part was retained as the neat (NE) and the other three parts were subjected to sperm selection by using migration–sedimentation (MS), density gradient (DG) separation, and swim-up (SU) techniques. Sperm functional characteristics along with mitochondrial integrity, tyrosine phosphorylation, acrosome reaction, and ultrastructure were measured. The ability of selection techniques in reducing spontaneous and radiation-induced sperm DNA lesions was assessed by the TUNEL assay. In results, MS-selected spermatozoa had higher viability (P < 0.001), longevity in terms of total motility at the end of 6 and 18 h post-extraction (P < 0.001), and mitochondrial integrity (P < 0.001) compared with those selected by DG. Furthermore, spontaneous DNA lesions were significantly reduced in MS and SU fractions compared with NE (P < 0.001). Similarly, radiation-induced sperm DNA lesions were significantly lower in MS and SU fractions (P < 0.001) compared with DG. Ultrastructural analysis using scanning electron microscopy suggested a moderate, non-significant increase in the number of spermatozoa with normal head and mid-piece in MS fraction compared with other methods. In conclusion, the MS-based device offers a centrifugation-free, efficient, and reliable sperm selection method, making it suitable for partially equipped intra-uterine insemination (IUI) laboratories or office IUI programmes. Further research should focus on the safety and clinical usefulness of the device in assisted conception programmes in general and IUI in specific.
Collapse
Affiliation(s)
- Huidrom Yaiphaba Meitei
- Department of Clinical Embryology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Shubhashree Uppangala
- Department of Clinical Embryology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Krishna Sharan
- Department of Radiation Oncology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India
| | | | | | - Guruprasad Kalthur
- Department of Clinical Embryology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Stefan Schlatt
- Centre of Reproductive Medicine and Andrology, Albert-Schweitzer Campus 11, 48149, Münster, Germany
| | - Satish Kumar Adiga
- Department of Clinical Embryology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India.
| |
Collapse
|
31
|
Rehfeld A, Mendoza N, Ausejo R, Skakkebæk NE. Bisphenol A Diglycidyl Ether (BADGE) and Progesterone Do Not Induce Ca 2+ Signals in Boar Sperm Cells. Front Physiol 2020; 11:785. [PMID: 32774306 PMCID: PMC7381341 DOI: 10.3389/fphys.2020.00785] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 06/15/2020] [Indexed: 12/22/2022] Open
Abstract
Aim Exposure of boar sperm cells to Bisphenol A diglycidyl ether (BADGE) has been shown to lead to reproductive failure in sows, however, the mode of action is unknown. As we have recently shown that BADGE can interfere with Ca2 + signaling in human sperm cells through an action on CatSper, and as CatSper has been shown to be expressed in boar sperm cells, we hypothesized that a similar mechanism in the boar sperm cells could be responsible for the reproductive failure. Methods Direct effects of BADGE and the endogenous ligand of human CatSper, progesterone, on Ca2+ signaling in human and boar sperm cells were evaluated side-by-side using a Ca2+ fluorimetric assay measuring changes in intracellular Ca2+. Effects of BADGE on Ca2+ signaling in boar sperm were furthermore assessed by flow cytometry by an independent laboratory. Results The exact same solutions of BADGE and progesterone induced transient biphasic Ca2+ signals in human sperm cells, but failed to do so in both non-capacitated and capacitated boar sperm cells. BADGE also failed to induce transient biphasic Ca2+ signals in boar sperm cells in the flow cytometric assay. Conclusion BADGE and progesterone failed to induce Ca2+ signals in boar sperm cells. This indicates that the signaling mechanisms leading to activation of CatSper differs between human and boar sperm cells, and suggests that the mode of action by which exposure of boar sperm cells to BADGE can lead to reproductive failure in sows does not involve effects on Ca2+ signaling.
Collapse
Affiliation(s)
- Anders Rehfeld
- Department of Growth and Reproduction, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.,International Center for Research and Research Training in Endocrine Disruption of Male Reproduction and Child Health (EDMaRC), Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Noelia Mendoza
- Department of Research and Development, Magapor SL, Zaragoza, Spain
| | - Raquel Ausejo
- Department of Research and Development, Magapor SL, Zaragoza, Spain
| | - Niels Erik Skakkebæk
- Department of Growth and Reproduction, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.,International Center for Research and Research Training in Endocrine Disruption of Male Reproduction and Child Health (EDMaRC), Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|