1
|
Strategies to capitalize on cell spheroid therapeutic potential for tissue repair and disease modeling. NPJ Regen Med 2022; 7:70. [PMID: 36494368 PMCID: PMC9734656 DOI: 10.1038/s41536-022-00266-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 11/29/2022] [Indexed: 12/13/2022] Open
Abstract
Cell therapies offer a tailorable, personalized treatment for use in tissue engineering to address defects arising from trauma, inefficient wound repair, or congenital malformation. However, most cell therapies have achieved limited success to date. Typically injected in solution as monodispersed cells, transplanted cells exhibit rapid cell death or insufficient retention at the site, thereby limiting their intended effects to only a few days. Spheroids, which are dense, three-dimensional (3D) aggregates of cells, enhance the beneficial effects of cell therapies by increasing and prolonging cell-cell and cell-matrix signaling. The use of spheroids is currently under investigation for many cell types. Among cells under evaluation, spheroids formed of mesenchymal stromal cells (MSCs) are particularly promising. MSC spheroids not only exhibit increased cell survival and retained differentiation, but they also secrete a potent secretome that promotes angiogenesis, reduces inflammation, and attracts endogenous host cells to promote tissue regeneration and repair. However, the clinical translation of spheroids has lagged behind promising preclinical outcomes due to hurdles in their formation, instruction, and use that have yet to be overcome. This review will describe the current state of preclinical spheroid research and highlight two key examples of spheroid use in clinically relevant disease modeling. It will highlight techniques used to instruct the phenotype and function of spheroids, describe current limitations to their use, and offer suggestions for the effective translation of cell spheroids for therapeutic treatments.
Collapse
|
2
|
Development of an ultrasound guided focused ultrasound system for 3D volumetric low energy nanodroplet-mediated histotripsy. Sci Rep 2022; 12:20664. [PMID: 36450815 PMCID: PMC9712369 DOI: 10.1038/s41598-022-25129-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 11/24/2022] [Indexed: 12/03/2022] Open
Abstract
Low pressure histotripsy is likely to facilitate current treatments that require extremely high pressures. An ultrasound guided focused ultrasound system was designed to accommodate a rotating imaging transducer within a low frequency therapeutic transducer that operates at a center frequency of 105 kHz. The implementation of this integrated system provides real-time therapeutic and volumetric imaging functions, that are used here for low-cost, low-energy 3D volumetric ultrasound histotripsy using nanodroplets. A two-step approach for low pressure histotripsy is implemented with this dual-array. Vaporization of nanodroplets into gaseous microbubbles was performed via the 1D rotating imaging probe. The therapeutic transducer is then used to detonate the vaporized nanodroplets and trigger potent mechanical effects in the surrounding tissue. Rotating the imaging transducer creates a circular vaporized nanodroplet shape which generates a round lesion upon detonation. This contrasts with the elongated lesion formed when using a standard 1D imaging transducer for nanodroplet activation. Optimization experiments show that maximal nanodroplet activation can be achieved with a 2-cycle excitation pulse at a center frequency of 3.5 MHz, and a peak negative pressure of 3.4 MPa (a mechanical index of 1.84). Vaporized nanodroplet detonation was achieved by applying a low frequency treatment at a center frequency of 105 kHz and mechanical index of 0.9. In ex-vivo samples, the rotated nanodroplet activation method yielded the largest lesion area, with a mean of 4.7 ± 0.5 mm2, and a rounded shape. In comparison, standard fixed transducer nanodroplet activation resulted in an average lesion area of 2.6 ± 0.4 mm2, and an elongated shape. This hybrid system enables to achieve volumetric low energy histotripsy, and thus facilitates the creation of precise, large-volume mechanical lesions in tissues, while reducing the pressure threshold required for standard histotripsy by over an order of magnitude.
Collapse
|
3
|
Benton RP, Al Rifai N, Stone K, Clark A, Zhang B, Haworth KJ. Impact of Perfluoropentane Microdroplets Diameter and Concentration on Acoustic Droplet Vaporization Transition Efficiency and Oxygen Scavenging. Pharmaceutics 2022; 14:pharmaceutics14112392. [PMID: 36365210 PMCID: PMC9694497 DOI: 10.3390/pharmaceutics14112392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 10/25/2022] [Accepted: 11/02/2022] [Indexed: 11/09/2022] Open
Abstract
Acoustic droplet vaporization is the ultrasound-mediated phase change of liquid droplets into gas microbubbles. Following the phase change, oxygen diffuses from the surrounding fluid into the microbubble. An in vitro model was used to study the effects of droplet diameter, the presence of an ultrasound contrast agent, ultrasound duty cycle, and droplet concentration on the magnitude of oxygen scavenging in oxygenated deionized water. Perfluoropentane droplets were manufactured through a microfluidic approach at nominal diameters of 1, 3, 5, 7, 9, and 12 µm and studied at concentrations varying from 5.1 × 10-5 to 6.3 × 10-3 mL/mL. Droplets were exposed to an ultrasound transduced by an EkoSonicTM catheter (2.35 MHz, 47 W, and duty cycles of 1.70%, 2.34%, or 3.79%). Oxygen scavenging and the total volume of perfluoropentane that phase-transitioned increased with droplet concentration. The ADV transition efficiency decreased with increasing droplet concentration. The increasing duty cycle resulted in statistically significant increases in oxygen scavenging for 1, 3, 5, and 7 µm droplets, although the increase was smaller than when the droplet diameter or concentration were increased. Under the ultrasound conditions tested, droplet diameter and concentration had the greatest impact on the amount of ADV and subsequent oxygen scavenging occurred, which should be considered when using ADV-mediated oxygen scavenging in therapeutic ultrasounds.
Collapse
Affiliation(s)
- Rachel P. Benton
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH 45267, USA
| | - Nour Al Rifai
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH 45267, USA
| | - Kateryna Stone
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH 45267, USA
| | - Abigail Clark
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH 45267, USA
| | - Bin Zhang
- Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229, USA
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH 45229, USA
| | - Kevin J. Haworth
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, OH 45267, USA
- Department of Pediatrics, University of Cincinnati, Cincinnati, OH 45229, USA
- Correspondence: ; Tel.: +1-513-558-3536
| |
Collapse
|
4
|
Kaymaz B, Mustafa W, Hall S, Vlaisavljevich E, Sensoy O, Yuksel Durmaz Y. Experimental and Computational Investigation of Clustering Behavior of Cyclodextrin-Perfluorocarbon Inclusion Complexes as Effective Histotripsy Agents. Mol Pharm 2022; 19:2907-2921. [PMID: 35839291 DOI: 10.1021/acs.molpharmaceut.2c00268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Recently developed nanocones (NCs), which are inclusion complexes that are made up of cyclodextrins (CDs) and perfluorocarbons (PFCs), have shown promising results in nanoparticle-mediated histotripsy (NMH) applications due to stable inclusion complexation, PFC quantification, simple synthesis, and processing. FDA-approved βCD and its modified versions such as low-degree methylated βCD have been previously demonstrated as prime examples of structures capable of accommodating PFC molecules. However, the complex formation potential of different CDs with various cavity sizes in the presence of PFC molecules, and their consequent aggregation, needs to be explored. In the present study, the complexation and aggregation potential of some natural CDs and their respective derivatives either exposed to perfluoropentane (PFP) or perfluorohexane (PFH) were studied in the wet lab. Computational studies were also performed to account for the limitations faced in PFC quantification because of the low optical density of PFCs within the CD complex and to discover the best candidate for NMH applications. All results revealed that only βCD and γCD (except HMγCD) derivatives form an inclusion complex with PFCs and only LMβCD, βCD, and γCD form nanocone clusters (NCCs), which precipitate and can be collected for use. Furthermore, the data collectively show that βCD and PFCs have the best complexation due to stable complex formation, ease of production, and product recovery, especially with PFH as a more suitable candidate due to its high boiling point, which allows workability during synthesis. Although simulations suggest that highly stable inclusion complexes exist, such as HPβCD, the cluster formation resulting in precipitation is hindered due to the high solubility of CDs in water, resulting in intangible yields to work with even after employing general laboratory recovery methods. Conclusively, histotripsy cavitation experiments successfully showed a decreased cavitation threshold among optimal NCC candidates that were identified, supporting their use in NMH.
Collapse
Affiliation(s)
- Betül Kaymaz
- Department of Biomedical Engineering, School of Engineering and Natural Sciences, Istanbul Medipol University, 34810 Istanbul, Turkey
| | - Waleed Mustafa
- Department of Biomedical Engineering, School of Engineering and Natural Sciences, Istanbul Medipol University, 34810 Istanbul, Turkey
| | - Sarah Hall
- Department of Biomedical Engineering and Mechanics, Virginia Tech 24061, United States
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech 24061, United States
| | - Ozge Sensoy
- Department of Biomedical Engineering, School of Engineering and Natural Sciences, Istanbul Medipol University, 34810 Istanbul, Turkey.,Research Institute of Health Science and Technologies (SABITA), Istanbul Medipol University, 34810 Istanbul, Turkey
| | - Yasemin Yuksel Durmaz
- Department of Biomedical Engineering, School of Engineering and Natural Sciences, Istanbul Medipol University, 34810 Istanbul, Turkey.,Research Institute of Health Science and Technologies (SABITA), Istanbul Medipol University, 34810 Istanbul, Turkey
| |
Collapse
|
5
|
Glickstein B, Levron M, Shitrit S, Aronovich R, Feng Y, Ilovitsh T. Nanodroplet-Mediated Low-Energy Mechanical Ultrasound Surgery. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1229-1239. [PMID: 35351316 DOI: 10.1016/j.ultrasmedbio.2022.02.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/08/2022] [Accepted: 02/17/2022] [Indexed: 06/14/2023]
Abstract
Mechanical ultrasound surgery methods use short, high-intensity pulses to fractionate tissues. This study reports the development of a two-step technology for low-energy mechanical ultrasound surgery of tissues using nanodroplets to reduce the pressure threshold. Step 1 consists of vaporizing the nanodroplets into gaseous microbubbles via megahertz ultrasound excitation. Then, low-frequency ultrasound is applied to the microbubbles, which turns them into therapeutic warheads that trigger potent mechanical effects in the surrounding tissue. The use of nanoscale nanodroplets coupled with low-frequency ultrasound reduces the pressure threshold required for mechanical ultrasound surgery by an order of magnitude. In addition, their average diameter of 300 nm can overcome challenges associated with the size of microbubbles. Optimization experiments were performed to determine the ultrasound parameters for nanodroplet vaporization and the subsequent microbubble implosion processes. Optimal vaporization was obtained when transmitting a 2-cycle excitation pulse at a center frequency of 5 MHz and a peak negative pressure of 4.1 MPa (mechanical index = 1.8). Low-frequency insonation of the generated microbubbles at a center frequency of 850, 250 or 80 kHz caused enhanced contrast reduction at a center frequency of 80 kHz, compared with the other frequencies, while operating at the same mechanical index of 0.9. Nanodroplet-mediated insonation of ex vivo chicken liver samples generated mechanical damage. Low-frequency treatment at a mechanical index of 0.9 and a center frequency of 80 kHz induced the largest lesion area (average of 0.59 mm2) compared with 250- and 850-kHz treatments with the same mechanical index (average lesions areas of 0.29 and 0.19 mm2, respectively, p < 0.001). The two-step approach makes it possible to conduct both the vaporization and implosion stages at mechanical indices below 1.9, thus avoiding undesired mechanical damage. The findings indicate that coupled with low-frequency ultrasound, nanodroplets can be used for low-energy mechanical ultrasound surgery.
Collapse
Affiliation(s)
- Bar Glickstein
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Mika Levron
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Sarah Shitrit
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Ramona Aronovich
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Yi Feng
- Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China
| | - Tali Ilovitsh
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel; Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
6
|
Kip B, Tunc CU, Aydin O. Triple-combination therapy assisted with ultrasound-active gold nanoparticles and ultrasound therapy against 3D cisplatin-resistant ovarian cancer model. ULTRASONICS SONOCHEMISTRY 2022; 82:105903. [PMID: 34974392 PMCID: PMC8799745 DOI: 10.1016/j.ultsonch.2021.105903] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/17/2021] [Accepted: 12/28/2021] [Indexed: 05/13/2023]
Abstract
Cancer chemotherapy suffers from drug resistance and side effects of the drugs. Combination therapies have been attracted attention to overcome these limitations of traditional cancer treatments. Recently, increasing in intracellular chemotherapeutic concentration in the presence of ultrasonic waves (US) has been shown in the preclinical stage. In addition, some recent studies have shown that nanoparticles increase the effectiveness of ultrasound therapy. In this study, the US-active property of gold nanocones (AuNCs) was utilized for combinational US and cisplatin (Cis) to overcome drug resistance. The effect of the triple combination therapy US + AuNCs + Cis with low-dose Cis on 2/3D models of cisplatin-resistant ovarian cancer cell line (A2780cis) were investigated. In the 2D cell culture, 60% of the A2780cis cell population was suppressed with triple combination therapy; and the long-term therapeutic efficacy of the US + AuNCs + Cis with the low-dose drug was demonstrated by suppressing 83% of colony formation. According to the results in the 3D cell model, 60% of the spheroid formation was suppressed by the triple combination therapy with low-dose Cis. These results not only demonstrate the success of the US + AuNCs + Cis triple combination therapy for its long-term therapeutic effect on resistant cancer cells but also verified that it might enable effective cancer therapy in vivo and clinical stages based on the 3D tumor models. In addition, enhanced anti-cancer activity was demonstrated at the low-dose Cis on drug-resistant cancer cells indicating the triple-combination therapy successfully overcame drug resistance and this is a promising strategy to reduce the side effects of chemotherapy. This work exhibits a novel US and AuNCs-mediated combination cancer therapy, which demonstrates the role of ultrasound-active AuNCs to combat drug resistance with low-dose chemotherapy.
Collapse
Affiliation(s)
- Bilgi Kip
- Department of Biomedical Engineering, Erciyes University, Kayseri 38039, Turkey; NanoThera Lab, ERFARMA-Drug Development and Implementation Center, Erciyes University, 38039 Kayseri, Turkey
| | - Cansu Umran Tunc
- Department of Biomedical Engineering, Erciyes University, Kayseri 38039, Turkey; NanoThera Lab, ERFARMA-Drug Development and Implementation Center, Erciyes University, 38039 Kayseri, Turkey
| | - Omer Aydin
- Department of Biomedical Engineering, Erciyes University, Kayseri 38039, Turkey; NanoThera Lab, ERFARMA-Drug Development and Implementation Center, Erciyes University, 38039 Kayseri, Turkey; ERNAM-Nanotechnology Research and Application Center, Erciyes University, Kayseri 38039, Turkey; ERKAM-Clinical Engineering Research and Application Center, Erciyes University, Kayseri 38040, Turkey.
| |
Collapse
|
7
|
Krafft MP, Riess JG. Therapeutic oxygen delivery by perfluorocarbon-based colloids. Adv Colloid Interface Sci 2021; 294:102407. [PMID: 34120037 DOI: 10.1016/j.cis.2021.102407] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 03/18/2021] [Accepted: 03/25/2021] [Indexed: 02/06/2023]
Abstract
After the protocol-related indecisive clinical trial of Oxygent, a perfluorooctylbromide/phospholipid nanoemulsion, in cardiac surgery, that often unduly assigned the observed untoward effects to the product, the development of perfluorocarbon (PFC)-based O2 nanoemulsions ("blood substitutes") has come to a low. Yet, significant further demonstrations of PFC O2-delivery efficacy have continuously been reported, such as relief of hypoxia after myocardial infarction or stroke; protection of vital organs during surgery; potentiation of O2-dependent cancer therapies, including radio-, photodynamic-, chemo- and immunotherapies; regeneration of damaged nerve, bone or cartilage; preservation of organ grafts destined for transplantation; and control of gas supply in tissue engineering and biotechnological productions. PFC colloids capable of augmenting O2 delivery include primarily injectable PFC nanoemulsions, microbubbles and phase-shift nanoemulsions. Careful selection of PFC and other colloid components is critical. The basics of O2 delivery by PFC nanoemulsions will be briefly reminded. Improved knowledge of O2 delivery mechanisms has been acquired. Advanced, size-adjustable O2-delivering nanoemulsions have been designed that have extended room-temperature shelf-stability. Alternate O2 delivery options are being investigated that rely on injectable PFC-stabilized microbubbles or phase-shift PFC nanoemulsions. The latter combine prolonged circulation in the vasculature, capacity for penetrating tumor tissues, and acute responsiveness to ultrasound and other external stimuli. Progress in microbubble and phase-shift emulsion engineering, control of phase-shift activation (vaporization), understanding and control of bubble/ultrasound/tissue interactions is discussed. Control of the phase-shift event and of microbubble size require utmost attention. Further PFC-based colloidal systems, including polymeric micelles, PFC-loaded organic or inorganic nanoparticles and scaffolds, have been devised that also carry substantial amounts of O2. Local, on-demand O2 delivery can be triggered by external stimuli, including focused ultrasound irradiation or tumor microenvironment. PFC colloid functionalization and targeting can help adjust their properties for specific indications, augment their efficacy, improve safety profiles, and expand the range of their indications. Many new medical and biotechnological applications involving fluorinated colloids are being assessed, including in the clinic. Further uses of PFC-based colloidal nanotherapeutics will be briefly mentioned that concern contrast diagnostic imaging, including molecular imaging and immune cell tracking; controlled delivery of therapeutic energy, as for noninvasive surgical ablation and sonothrombolysis; and delivery of drugs and genes, including across the blood-brain barrier. Even when the fluorinated colloids investigated are designed for other purposes than O2 supply, they will inevitably also carry and deliver a certain amount of O2, and may thus be considered for O2 delivery or co-delivery applications. Conversely, O2-carrying PFC nanoemulsions possess by nature a unique aptitude for 19F MR imaging, and hence, cell tracking, while PFC-stabilized microbubbles are ideal resonators for ultrasound contrast imaging and can undergo precise manipulation and on-demand destruction by ultrasound waves, thereby opening multiple theranostic opportunities.
Collapse
Affiliation(s)
- Marie Pierre Krafft
- University of Strasbourg, Institut Charles Sadron (CNRS), 23 rue du Loess, 67034 Strasbourg, France.
| | - Jean G Riess
- Harangoutte Institute, 68160 Ste Croix-aux-Mines, France
| |
Collapse
|
8
|
Latifi M, Hay A, Carroll J, Dervisis N, Arnold L, Coutermarsh-Ott SL, Kierski KR, Klahn S, Allen IC, Vlaisavljevich E, Tuohy J. Focused ultrasound tumour ablation in small animal oncology. Vet Comp Oncol 2021; 19:411-419. [PMID: 34057278 DOI: 10.1111/vco.12742] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 04/29/2021] [Accepted: 05/24/2021] [Indexed: 12/20/2022]
Abstract
The cancer incidence rates for humans and animals remain high, and efforts to improve cancer treatment are crucial. Cancer treatment for solid tumours includes both treatment of the primary tumour and of metastasis. Surgery is commonly employed to resect primary and metastatic tumours, but is invasive, and is not always the optimal treatment modality. Prevention and treatment of metastatic disease often utilizes a multimodal approach, but metastasis remains a major cause of death for both human and veterinary cancer patients. Focused ultrasound (FUS) tumour ablation techniques represent a novel non-invasive approach to treating cancer. FUS ablation is precise, thus sparing adjacent critical structures while ablating the tumour. FUS ablation can occur in a thermal or non-thermal fashion. Thermal FUS ablation, also known as high intensity focused ultrasound (HIFU) ablation, destroys tumour cells via heat, whereas non-thermal FUS, known as histotripsy, ablates tumour cells via mechanical disintegration of tissue. Not only can HIFU and histotripsy ablate tumours, they also demonstrate potential to upregulate the host immune system towards an anti-tumour response. The aim of this report is provide a description of HIFU and histotripsy tumour ablation, with a focus on the basic principles of their ablation mechanisms and their clinical applicability in the field of veterinary oncology.
Collapse
Affiliation(s)
- Max Latifi
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA.,Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA
| | - Alayna Hay
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA
| | - Jennifer Carroll
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA
| | - Nikolaos Dervisis
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA
| | - Lauren Arnold
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Sheryl L Coutermarsh-Ott
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA
| | - Katharine R Kierski
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA
| | - Shawna Klahn
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA
| | - Irving C Allen
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, Virginia, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Joanne Tuohy
- Animal Cancer Care and Research Center, Virginia-Maryland College of Veterinary Medicine, Roanoke, Virginia, USA
| |
Collapse
|
9
|
Gao B, Xu J, Zhou J, Zhang H, Yang R, Wang H, Huang J, Yan F, Luo Y. Multifunctional pathology-mapping theranostic nanoplatforms for US/MR imaging and ultrasound therapy of atherosclerosis. NANOSCALE 2021; 13:8623-8638. [PMID: 33929480 DOI: 10.1039/d1nr01096d] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Atherosclerotic thrombosis is the leading cause of most life-threatening cardiovascular diseases (CVDs), particularly as a result of rupture or erosion of vulnerable plaques. Rupture or erosion-prone plaques are quite different in cellular composition and immunopathology, requiring different treatment strategies. The current imaging technology cannot distinguish the types of vulnerable plaques, and thus empirical treatment is still applied to all without a tailored and precise treatment. Herein, we propose a novel strategy called "Multifunctional Pathology-mapping Theranostic Nanoplatform (MPmTN)" for the tailored treatment of plaques based on the pathological classification. MPmTNs are made up of poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs), containing contrast imaging materials Fe3O4 and perfluoropentane (PFP), and coated with specific plaque-targeted peptides PP1 and cyclic RGD. The PFP encapsulated inside the MPmTN can undergo a phase change from nanodroplets to gas microbubbles under therapeutic ultrasound (TUS) exposure. The acoustic and biological effects induced by TUS and disruption of microbubbles may further promote therapeutic effects. Hypothetically, MPmTN NPs can target the rupture-prone plaque via the binding of PP1 to class A scavenger receptors (SR-A) on macrophages, induce the apoptosis due to TUS exposure and thus reduce the chronic soakage of inflammatory cells. The MPmTN NPs can also target the erosion-prone plaque through the binding of cRGD to glycoprotein (GP) IIb/IIIa on activated platelets and promote platelet disaggregation under TUS exposure. Therefore, MPmTNs may work as a multifunctional pathology-mapping therapeutic agent. Our in vitro results show that the MPmTN with PP1 and cRGD peptides had a high binding affinity both for activated macrophages and blood clots. Under TUS exposure, the MPmTN could effectively induce macrophage apoptosis, destroy thrombus and exhibit good imaging properties for ultrasound (US) and MRI. In apoE-/- mice, MPmTNs can selectively accumulate at the plaque site and reduce the T2-weighted signal. The apoptosis of macrophages and disaggregation of activated platelets on the plaques were also confirmed in vivo. In summary, this study provides a potential strategy for a tailored treatment of vulnerable plaques based on their pathological nature and a multimodal imaging tool for the risk stratification and assessment of therapeutic efficacy.
Collapse
Affiliation(s)
- Binyang Gao
- Department of Ultrasound, Laboratory of Ultrasound Imaging and Drug, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Edsall C, Khan ZM, Mancia L, Hall S, Mustafa W, Johnsen E, Klibanov AL, Durmaz YY, Vlaisavljevich E. Bubble Cloud Behavior and Ablation Capacity for Histotripsy Generated from Intrinsic or Artificial Cavitation Nuclei. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:620-639. [PMID: 33309443 PMCID: PMC8514340 DOI: 10.1016/j.ultrasmedbio.2020.10.020] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 10/26/2020] [Accepted: 10/28/2020] [Indexed: 05/04/2023]
Abstract
The study described here examined the effects of cavitation nuclei characteristics on histotripsy. High-speed optical imaging was used to compare bubble cloud behavior and ablation capacity for histotripsy generated from intrinsic and artificial cavitation nuclei (gas-filled microbubbles, fluid-filled nanocones). Results showed a significant decrease in the cavitation threshold for microbubbles and nanocones compared with intrinsic-nuclei controls, with predictable and well-defined bubble clouds generated in all cases. Red blood cell experiments showed complete ablations for intrinsic and nanocone phantoms, but only partial ablation in microbubble phantoms. Results also revealed a lower rate of ablation in artificial-nuclei phantoms because of reduced bubble expansion (and corresponding decreases in stress and strain). Overall, this study demonstrates the potential of using artificial nuclei to reduce the histotripsy cavitation threshold while highlighting differences in the bubble cloud behavior and ablation capacity that need to be considered in the future development of these approaches.
Collapse
Affiliation(s)
- Connor Edsall
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA.
| | - Zerin Mahzabin Khan
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Lauren Mancia
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Sarah Hall
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Waleed Mustafa
- Department of Biomedical Engineering, Istanbul Medipol University, Beykoz/İstanbul, Turkey
| | - Eric Johnsen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Alexander L Klibanov
- Cardiovascular Division, Department of Medicine, University of Virginia, Charlottesville, Virginia
| | - Yasemin Yuksel Durmaz
- Department of Biomedical Engineering, Istanbul Medipol University, Beykoz/İstanbul, Turkey; Regenerative and Restorative Medicine Research Center (REMER), Istanbul Medipol University, Beykoz/İstanbul, Turkey
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA; ICTAS Center for Engineered Health, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| |
Collapse
|
11
|
Bhagat SD, Chanchal A, Gujrati M, Banerjee A, Mishra RK, Srivastava A. Implantable HDAC-inhibiting chemotherapeutics derived from hydrophobic amino acids for localized anticancer therapy. Biomater Sci 2021; 9:261-271. [PMID: 33196720 DOI: 10.1039/d0bm01417f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Epigenetic targeting of different cancers by inhibiting particular histone deacetylase (HDAC) isozymes is a promising treatment approach against cancer. Development of locally-implantable molecular inhibitors of HDAC (henceforth called HDACi) promises high tumour site concentration and reduced systemic degradation of the HDACi. Herein, we report the design of such implantable HDACi based on amphiphilic derivatives of hydrophobic amino acids endowed with a hydroxamic acid (hxa)-based zinc-binding residue. The amino acids present in HDACi influenced the HDAC isozyme that could be inhibited most effectively; the l-phenylalanine derivative 4e inhibited the HDAC6 isozyme most potently (IC50 ∼ 88 nM), while the l-isoleucine derivative 4h was most effective against the isozyme HDAC2 (IC50 ∼ 94 nM). We also noticed that the l-Phe derivative 4e was up to 5× more potent towards inhibiting HDAC6 than its optical antipode 4f derived from d-Phe. This was rationalized in terms of the varying extent of penetration of the enantiomeric inhibitors inside the catalytic tunnel of the enzyme. Since the isozymes HDAC6 and HDAC2 are overexpressed in different cancer cells, 4e and 4h elicited selective anticancer activity in different cancer cell lines. Additive therapeutic action of the combination therapy of 4e and 4h was observed on lung cancer cells that overexpress both these isozymes. Further, 4e formed implantable self-assembled hydrogels that achieved sustained and selective killing of cancer cells in the vicinity of implantation.
Collapse
Affiliation(s)
- Somnath Dharmaraj Bhagat
- Department of Chemistry, Indian Institute of Science Education and Research Bhopal, Bhopal Bypass Road, Bhopal, Madhya Pradesh 462066, India.
| | | | | | | | | | | |
Collapse
|
12
|
Xu T, Cui Z, Li D, Cao F, Xu J, Zong Y, Wang S, Bouakaz A, Wan M, Zhang S. Cavitation characteristics of flowing low and high boiling-point perfluorocarbon phase-shift nanodroplets during focused ultrasound exposures. ULTRASONICS SONOCHEMISTRY 2020; 65:105060. [PMID: 32199255 DOI: 10.1016/j.ultsonch.2020.105060] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 01/15/2020] [Accepted: 03/07/2020] [Indexed: 06/10/2023]
Abstract
This work investigated and compared the dynamic cavitation characteristics between low and high boiling-point phase-shift nanodroplets (NDs) under physiologically relevant flow conditions during focused ultrasound (FUS) exposures at different peak rarefactional pressures. A passive cavitation detection (PCD) system was used to monitor cavitation activity during FUS exposure at various acoustic pressure levels. Root mean square (RMS) amplitudes of broadband noise, spectrograms of the passive cavitation detection signals, and normalized inertial cavitation dose (ICD) values were calculated. Cavitation activity of low-boiling-point perfluoropentane (PFP) NDs and high boiling-point perfluorohexane (PFH) NDs flowing at in vitro mean velocities of 0-15 cm/s were compared in a 4-mm diameter wall-less vessel in a transparent tissue-mimicking phantom. In the static state, both types of phase-shift NDs exhibit a sharp rise in cavitation intensity during initial FUS exposure. Under flow conditions, cavitation activity of the PFH NDs reached the steady state less rapidly compared to PFP NDs under the lower acoustic pressure (1.35 MPa); at the higher acoustic pressure (1.65 MPa), the RMS amplitude increased more sharply during the initial FUS exposure period. In particular, the RMS-time curves of the PFP NDs shifted upward as the mean flow velocity increased from 0 to 15 cm/s; the RMS amplitude of the PFH ND solution increased from 0 to 10 cm/s and decreased at 15 cm/s. Moreover, amplitudes of the echo signal for the low boiling-point PFP NDs were higher compared to the high boiling-point PFH NDs in the lower frequency range, whereas the inverse occurred in the higher frequency range. Both PFP and PFH NDs showed increased cavitation activity in the higher frequency under the flow condition compared to the static state, especially PFH NDs. At 1.65 MPa, normalized ICD values for PFH increased from 0.93 ± 0.03 to 0.96 ± 0.04 and from 0 to 10 cm/s, then decreased to 0.86 ± 0.05 at 15 cm/s. This work contributes to our further understanding of cavitation characteristics of phase-shift NDs under physiologically relevant flow conditions during FUS exposure. In addition, the results provide a reference for selecting suitable phase-shift NDs to enhance the efficiency of cavitation-mediated ultrasonic applications.
Collapse
Affiliation(s)
- Tianqi Xu
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Zhiwei Cui
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Dapeng Li
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Fangyuan Cao
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Jichen Xu
- Institute of Artificial Intelligence and Robotics, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China; National Engineering Laboratory for Visual Information Processing and Applications, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Supin Wang
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | | | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
| | - Siyuan Zhang
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
| |
Collapse
|
13
|
Liu Z, Ran H, Wang Z, Zhou S, Wang Y. Targeted and pH-facilitated theranostic of orthotopic gastric cancer via phase-transformation doxorubicin-encapsulated nanoparticles enhanced by low-intensity focused ultrasound (LIFU) with reduced side effect. Int J Nanomedicine 2019; 14:7627-7642. [PMID: 31571868 PMCID: PMC6757192 DOI: 10.2147/ijn.s212888] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 08/06/2019] [Indexed: 12/16/2022] Open
Abstract
Purpose Focused ultrasound-mediated chemotherapy, as a non-invasive therapeutic modality, has been extensively explored in combating deep tumors for predominant penetration performance. However, the generally used high-intensity focused ultrasound (HIFU) inevitably jeopardizes normal tissue around the lesion for hyperthermal energy. To overcome this crucial issue, low-intensity focused ultrasound (LIFU) was introduced to fulfill precisely controlled imaging and therapy in lieu of HIFU. The objective of this study was to develop a facile and versatile nanoplatform (DPP-R) in response to LIFU and provide targeted drug delivery concurrently. Methods Multifunctional DPP-R was fabricated by double emulsion method and carbodiimide method. Physicochemical properties of DPP-R were detected respectively and the bio-compatibility and bio-safety were evaluated by CCK-8 assay, blood analysis, and histologic section. The targeted ability, imaging function, and anti-tumor effect were demonstrated in vitro and vivo. Results The synthetic DPP-R showed an average particle size at 367 nm, stable physical-chemical properties in different media, and high bio-compatibility and bio-safety. DPP-R was demonstrated to accumulate at the tumor site by active receptor/ligand reaction and passive EPR effect with intravenous administration. Stimulated by LIFU at the tumor site, phase-transformable PFH was vaporized in the core of the integration offering contrast-enhanced ultrasound imaging. The stimuli led to encapsulated DOX's initial burst release and subsequent sustained release for anti-tumor therapy which was verified to be more effective and have less adverse effects than free DOX. Conclusion DPP-R combined with LIFU provides a novel theranostic modality for GC treatment with potent therapeutic effect, including prominent performance of targeting, ultrasound imaging, and accurate drug release.
Collapse
Affiliation(s)
- Zhangluxi Liu
- Department of Gastrointestinal Surgery, Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, People's Republic of China
| | - Haitao Ran
- Institute of Ultrasound Imaging of Chongqing Medical University, Chongqing 400010, People's Republic of China
| | - Zhigang Wang
- Institute of Ultrasound Imaging of Chongqing Medical University, Chongqing 400010, People's Republic of China
| | - Shiji Zhou
- Department of Gastrointestinal Surgery, Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, People's Republic of China
| | - Yaxu Wang
- Department of Gastrointestinal Surgery, Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, People's Republic of China
| |
Collapse
|
14
|
Loskutova K, Grishenkov D, Ghorbani M. Review on Acoustic Droplet Vaporization in Ultrasound Diagnostics and Therapeutics. BIOMED RESEARCH INTERNATIONAL 2019; 2019:9480193. [PMID: 31392217 PMCID: PMC6662494 DOI: 10.1155/2019/9480193] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 06/10/2019] [Accepted: 06/20/2019] [Indexed: 02/06/2023]
Abstract
Acoustic droplet vaporization (ADV) is the physical process in which liquid undergoes phase transition to gas after exposure to a pressure amplitude above a certain threshold. In recent years, new techniques in ultrasound diagnostics and therapeutics have been developed which utilize microformulations with various physical and chemical properties. The purpose of this review is to give the reader a general idea on how ADV can be implemented for the existing biomedical applications of droplet vaporization. In this regard, the recent developments in ultrasound therapy which shed light on the ADV are considered. Modern designs of capsules and nanodroplets (NDs) are shown, and the material choices and their implications for function are discussed. The influence of the physical properties of the induced acoustic field, the surrounding medium, and thermophysical effects on the vaporization are presented. Lastly, current challenges and potential future applications towards the implementation of the therapeutic droplets are discussed.
Collapse
Affiliation(s)
- Ksenia Loskutova
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, SE-141 57 Huddinge, Sweden
| | - Dmitry Grishenkov
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, SE-141 57 Huddinge, Sweden
| | - Morteza Ghorbani
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, SE-141 57 Huddinge, Sweden
- Mechatronics Engineering Program, Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
| |
Collapse
|
15
|
Zhang G, Lin S, Leow CH, Pang KT, Hernández-Gil J, Long NJ, Eckersley R, Matsunaga T, Tang MX. Quantification of Vaporised Targeted Nanodroplets Using High-Frame-Rate Ultrasound and Optics. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1131-1142. [PMID: 30827708 DOI: 10.1016/j.ultrasmedbio.2019.01.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 01/08/2019] [Accepted: 01/11/2019] [Indexed: 06/09/2023]
Abstract
Molecular targeted nanodroplets that can extravasate beyond the vascular space have great potential to improve tumor detection and characterisation. High-frame-rate ultrasound, on the other hand, is an emerging tool for imaging at a frame rate one to two orders of magnitude higher than those of existing ultrasound systems. In this study, we used high-frame-rate ultrasound combined with optics to study the acoustic response and size distribution of folate receptor (FR)-targeted versus non-targeted (NT)-nanodroplets in vitro with MDA-MB-231 breast cancer cells immediately after ultrasound activation. A flow velocity mapping technique, Stokes' theory and optical microscopy were used to estimate the size of both floating and attached vaporised nanodroplets immediately after activation. The floating vaporised nanodroplets were on average more than seven times larger than vaporised nanodroplets attached to the cells. The results also indicated that the acoustic signal of vaporised FR-targeted-nanodroplets persisted after activation, with 70% of the acoustic signals still present 1 s after activation, compared with the vaporised NT-nanodroplets, for which only 40% of the acoustic signal remained. The optical microscopic images revealed on average six times more vaporised FR-targeted-nanodroplets generated with a wider range of diameters (from 4 to 68 µm) that were still attached to the cells, compared with vaporised NT-nanodroplets (from 1 to 7 µm) with non-specific binding after activation. The mean size of attached vaporised FR-targeted-nanodroplets was on average about threefold larger than that of attached vaporised NT-nanodroplets. Taking advantage of high-frame-rate contrast-enhanced ultrasound and optical microscopy, this study offers an improved understanding of the vaporisation of the targeted nanodroplets in terms of their size and acoustic response in comparison with NT-nanodroplets. Such understanding would help in the design of optimised methodology for imaging and therapeutic applications.
Collapse
Affiliation(s)
- Ge Zhang
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Shengtao Lin
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Chee Hao Leow
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Kuin Tian Pang
- Institute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR), Singapore
| | | | - Nicholas J Long
- Department of Chemistry, Imperial College London, London, United Kingdom
| | - Robert Eckersley
- Division of Imaging Sciences & Biomedical Engineering Department, King's College London, United Kingdom
| | - Terry Matsunaga
- Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA
| | - Meng-Xing Tang
- Department of Bioengineering, Imperial College London, London, United Kingdom.
| |
Collapse
|
16
|
Bader KB, Vlaisavljevich E, Maxwell AD. For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1056-1080. [PMID: 30922619 PMCID: PMC6524960 DOI: 10.1016/j.ultrasmedbio.2018.10.035] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 09/28/2018] [Accepted: 10/03/2018] [Indexed: 05/04/2023]
Abstract
Histotripsy is a focused ultrasound therapy for non-invasive tissue ablation. Unlike thermally ablative forms of therapeutic ultrasound, histotripsy relies on the mechanical action of bubble clouds for tissue destruction. Although acoustic bubble activity is often characterized as chaotic, the short-duration histotripsy pulses produce a unique and consistent type of cavitation for tissue destruction. In this review, the action of histotripsy-induced bubbles is discussed. Sources of bubble nuclei are reviewed, and bubble activity over the course of single and multiple pulses is outlined. Recent innovations in terms of novel acoustic excitations, exogenous nuclei for targeted ablation and histotripsy-enhanced drug delivery and image guidance metrics are discussed. Finally, gaps in knowledge of the histotripsy process are highlighted, along with suggested means to expedite widespread clinical utilization of histotripsy.
Collapse
Affiliation(s)
- Kenneth B Bader
- Department of Radiology and Committee on Medical Physics, University of Chicago, Chicago, Illinois, USA.
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech University, Blacksburg, Virginia, USA
| | - Adam D Maxwell
- Department of Urology, University of Washington School of Medicine, Seattle, Washington, USA
| |
Collapse
|
17
|
Yildirim A, Blum NT, Goodwin AP. Colloids, nanoparticles, and materials for imaging, delivery, ablation, and theranostics by focused ultrasound (FUS). Theranostics 2019; 9:2572-2594. [PMID: 31131054 PMCID: PMC6525987 DOI: 10.7150/thno.32424] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 03/25/2019] [Indexed: 12/15/2022] Open
Abstract
This review focuses on different materials and contrast agents that sensitize imaging and therapy with Focused Ultrasound (FUS). At high intensities, FUS is capable of selectively ablating tissue with focus on the millimeter scale, presenting an alternative to surgical intervention or management of malignant growth. At low intensities, FUS can be also used for other medical applications such as local delivery of drugs and blood brain barrier opening (BBBO). Contrast agents offer an opportunity to increase selective acoustic absorption or facilitate destructive cavitation processes by converting incident acoustic energy into thermal and mechanical energy. First, we review the history of FUS and its effects on living tissue. Next, we present different colloidal or nanoparticulate approaches to sensitizing FUS, for example using microbubbles, phase-shift emulsions, hollow-shelled nanoparticles, or hydrophobic silica surfaces. Exploring the science behind these interactions, we also discuss ways to make stimulus-responsive, or "turn-on" contrast agents for improved selectivity. Finally, we discuss acoustically-active hydrogels and membranes. This review will be of interest to those working in materials who wish to explore new applications in acoustics and those in acoustics who are seeking new agents to improve the efficacy of their approaches.
Collapse
Affiliation(s)
- Adem Yildirim
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO 80303 USA
- Present address: CEDAR, Knight Cancer Institute, Oregon Health and Science University, Portland, OR, 97239 USA
| | - Nicholas T. Blum
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO 80303 USA
| | - Andrew P. Goodwin
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO 80303 USA
| |
Collapse
|
18
|
Rehman T, Khirallah J, Demirel E, Howell J, Vlaisavljevich E, Yuksel Durmaz Y. Development of Acoustically Active Nanocones Using the Host-Guest Interaction as a New Histotripsy Agent. ACS OMEGA 2019; 4:4176-4184. [PMID: 31459627 PMCID: PMC6649115 DOI: 10.1021/acsomega.8b02922] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 02/14/2019] [Indexed: 05/04/2023]
Abstract
Histotripsy is a noninvasive and nonthermal ultrasound ablation technique, which mechanically ablates the tissues using very short, focused, high-pressured ultrasound pulses to generate dense cavitating bubble cloud. Histotripsy requires large negative pressures (≥28 MPa) to generate cavitation in the target tissue, guided by real-time ultrasound imaging guidance. The high cavitation threshold and reliance on real-time image guidance are potential limitations of histotripsy, particularly for the treatment of multifocal or metastatic cancers. To address these potential limitations, we have recently developed nanoparticle-mediated histotripsy (NMH) where perfluorocarbon (PFC)-filled nanodroplets (NDs) with the size of ∼200 nm were used as cavitation nuclei for histotripsy, as they are able to significantly lower the cavitation threshold. However, although NDs were shown to be an effective histotripsy agent, they pose several issues. Their generation requires multistep synthesis, they lack long-term stability, and determination of PFC concentration in the treatment dose is not possible. In this study, PFC-filled nanocones (NCs) were developed as a new generation of histotripsy agents to address the mentioned limitations of NDs. The developed NCs represent an inclusion complex of methylated β-cyclodextrin as a water-soluble analog of β-cyclodextrin and perfluorohexane (PFH) as more effective PFC derivatives for histotripsy. Results showed that NCs are easy to produce, biocompatible, have a size <50 nm, and have a quantitative complexation that allows us to directly calculate the PFH amount in the used NC dose. Results further demonstrated that NCs embedded into tissue-mimicking phantoms generated histotripsy cavitation "bubble clouds" at a significantly lower transducer amplitude compared to control phantoms, demonstrating the ability of NCs to function as effective histotripsy agents for NMH.
Collapse
Affiliation(s)
- Tanzeel
Ur Rehman
- Department
of Biomedical Engineering, School of Engineering and Natural
Sciences, and Regenerative and Restorative Medicine Research Center (REMER), Istanbul Medipol University, Istanbul 34810, Turkey
| | - Jennifer Khirallah
- Department
of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg 24061, United States
| | - Erhan Demirel
- Department
of Biomedical Engineering, School of Engineering and Natural
Sciences, and Regenerative and Restorative Medicine Research Center (REMER), Istanbul Medipol University, Istanbul 34810, Turkey
| | - Justin Howell
- Department
of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg 24061, United States
| | - Eli Vlaisavljevich
- Department
of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg 24061, United States
- E-mail: (E.V.)
| | - Yasemin Yuksel Durmaz
- Department
of Biomedical Engineering, School of Engineering and Natural
Sciences, and Regenerative and Restorative Medicine Research Center (REMER), Istanbul Medipol University, Istanbul 34810, Turkey
- E-mail: (Y.Y.D.)
| |
Collapse
|
19
|
Fan CH, Lin YT, Ho YJ, Yeh CK. Spatial-Temporal Cellular Bioeffects from Acoustic Droplet Vaporization. Theranostics 2018; 8:5731-5743. [PMID: 30555577 PMCID: PMC6276289 DOI: 10.7150/thno.28782] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 10/16/2018] [Indexed: 01/04/2023] Open
Abstract
One of the major challenges in developing acoustic droplet vaporization (ADV)-associated therapy as an effective and safe strategy is the precise determination of the spatial cellular bioeffects after ADV (cell death or cell membrane permeabilization). In this study, we combined high-speed camera imaging and live-cell microscopic imaging to observe the transient dynamics of droplets during ADV and to evaluate the mechanical force on cells. Methods: C6 glioma cells were co-incubated with DiI-labeled droplets (radius: 1.5, 2.25, and 3.0 μm). We used an acousto-optical system for high-speed bright-field (500 kfps) and fluorescence (40 kfps) microscopic imaging in order to visualize the dynamics of droplets under ultrasound excitation (frequency = 5 MHz, pressure = 5-8 MPa, cycle number = 3, pulse number = 1). Live-cell microscopic imaging was used to monitor the cell morphology, cell membrane permeabilization, and cell viability by membrane-anchored Lyn-yellow fluorescence protein, propidium Iodide staining, and calcein blue AM staining, respectively. Results: We discovered that the spatial distribution of ADV-induced bioeffects could be mapped to the physical dynamics of droplet vaporization. For droplets with a 1.5 μm radius, the distance threshold for ADV-induced cell death (5.5±1.9 μm) and reversible membrane permeabilization (11.3±3.5 μm) was well correlated with the distance of ADV-bubble pressing downward to the floor (5.7±1.3 μm) and maximum distance of droplet expansion (11.5±2.6 μm), respectively. These distances were enlarged by increasing the droplet sizes and insonation acoustic pressures. The live-cell imaging results show that ADV-bubbles can directly disrupt the cell membrane layer and induce intensive intracellular substance leakage. Further, the droplets shed the payload onto nearby cells during ADV, suggesting ADV could directly induce adjacent cell death by physical force and enhancement of chemotherapy to distant cells. Conclusion: This study provide new insights into the ADV-mediated physicochemical synergic effect for medical applications.
Collapse
|
20
|
Fan CH, Lee YH, Ho YJ, Wang CH, Kang ST, Yeh CK. Macrophages as Drug Delivery Carriers for Acoustic Phase-Change Droplets. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1468-1481. [PMID: 29685589 DOI: 10.1016/j.ultrasmedbio.2018.03.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2017] [Revised: 03/06/2018] [Accepted: 03/14/2018] [Indexed: 05/19/2023]
Abstract
The major challenges in treating malignant tumors are transport of therapeutic agents to hypoxic regions and real-time assessment of successful drug release via medical imaging modalities. In this study, we propose the use of macrophages (RAW 264.7 cells) as carriers of drug-loaded phase-change droplets to penetrate ischemic or hypoxic regions within tumors. The droplets consist of perfluoropentane, lipid and the chemotherapeutic drug doxorubicin (DOX, DOX-droplets). The efficiency of DOX-droplet uptake, migration mobility and viability of DOX-droplet-loaded macrophages (DLMs) were measured using a transmembrane cell migration assay, the alamarBlue assay and flow cytometric analysis, respectively. Our results indicate the feasibility of utilizing macrophages as DOX-droplet carriers (DOX payload of DOX-droplets: 459.3 ± 35.8 µg/mL, efficiency of cell uptake DOX-droplets: 88.8 ± 3.5%). The migration mobility (total number of migrated microphages) of DLMs decreased to 32.3% compared with that of healthy macrophages, but the DLMs provided contrast-enhanced ultrasound imaging (1.7-fold enhancement) and anti-tumor effect (70.9% cell viability) after acoustic droplet vaporization, suggesting the potential theranostic applications of DLMs. Future work will assess the tumor penetration ability of DLMs, mechanical effect of droplet vaporization on in vivo anti-tumor therapy and the release of the carried drug by ultrasound-triggered vaporization.
Collapse
Affiliation(s)
- Ching-Hsiang Fan
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Ya-Hsuan Lee
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Yi-Ju Ho
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Chung-Hsin Wang
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Shih-Tsung Kang
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Chih-Kuang Yeh
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan.
| |
Collapse
|
21
|
Aliabouzar M, Kumar KN, Sarkar K. Acoustic vaporization threshold of lipid-coated perfluoropentane droplets. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:2001. [PMID: 29716255 PMCID: PMC5895468 DOI: 10.1121/1.5027817] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Phase shift droplets vaporizable by acoustic stimulation offer the advantages of producing microbubbles as contrast agents in situ as well as higher stability and the possibility of achieving smaller sizes. Here, the acoustic droplet vaporization (ADV) threshold of a suspension of droplets with a perfluoropentane (PFP) core (diameter 400-3000 nm) is acoustically measured as a function of the excitation frequency in a tubeless setup at room temperature. The changes in scattered responses-fundamental, sub-, and second harmonic-are investigated, a quantitative criterion is used to determine the ADV phenomenon, and findings are discussed. The average threshold obtained using three different scattered components increases with frequency-1.05 ± 0.28 MPa at 2.25 MHz, 1.89 ± 0.57 MPa at 5 MHz, and 2.34 ± 0.014 MPa at 10 MHz. The scattered response from vaporized droplets was also found to qualitatively match with that from an independently prepared lipid-coated microbubble suspension in magnitude as well as trends above the determined ADV threshold value.
Collapse
Affiliation(s)
- Mitra Aliabouzar
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC 20052, USA
| | - Krishna N Kumar
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC 20052, USA
| | - Kausik Sarkar
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC 20052, USA
| |
Collapse
|
22
|
Yildirim A, Chattaraj R, Blum NT, Shi D, Kumar K, Goodwin AP. Phospholipid Capped Mesoporous Nanoparticles for Targeted High Intensity Focused Ultrasound Ablation. Adv Healthc Mater 2017; 6:10.1002/adhm.201700514. [PMID: 28699308 PMCID: PMC5627974 DOI: 10.1002/adhm.201700514] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Revised: 05/25/2017] [Indexed: 01/20/2023]
Abstract
The mechanical effects of cavitation can be effective for therapy but difficult to control, thus potentially leading to off-target side effects in patients. While administration of ultrasound active agents such as fluorocarbon microbubbles and nanodroplets can locally enhance the effects of high intensity focused ultrasound (HIFU), it has been challenging to prepare ultrasound active agents that are small and stable enough to accumulate in tumors and internalize into cancer cells. Here, this paper reports the synthesis of 100 nm nanoparticle ultrasound agents based on phospholipid-coated, mesoporous, hydrophobically functionalized silica nanoparticles that can internalize into cancer cells and remain acoustically active. The ultrasound agents produce bubbles when subjected to short HIFU pulses (≈6 µs) with peak negative pressure as low as ≈7 MPa and at particle concentrations down to 12.5 µg mL-1 (7 × 109 particles mL-1 ). Importantly, ultrasound agents are effectively uptaken by cancer cells without cytotoxic effects, but HIFU insonation causes destruction of the cells by the acoustically generated bubbles, as demonstrated by (2,3-bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide (XTT) and lactate dehydrogenase assays and flow cytometry. Finally, it is showed that the HIFU dose required to effectively eliminate cancer cells in the presence of ultrasound agents causes only a small temperature increase of ≈3.5 °C.
Collapse
Affiliation(s)
- Adem Yildirim
- Department of Chemical Biological Engineering, University of Colorado Boulder, Boulder, CO, 80303, USA
| | - Rajarshi Chattaraj
- Department of Chemical Biological Engineering, University of Colorado Boulder, Boulder, CO, 80303, USA
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, 80309, USA
| | - Nicholas T Blum
- Department of Chemical Biological Engineering, University of Colorado Boulder, Boulder, CO, 80303, USA
| | - Dennis Shi
- Department of Chemical Biological Engineering, University of Colorado Boulder, Boulder, CO, 80303, USA
| | - Kaushlendra Kumar
- Department of Chemical Biological Engineering, University of Colorado Boulder, Boulder, CO, 80303, USA
| | - Andrew P Goodwin
- Department of Chemical Biological Engineering, University of Colorado Boulder, Boulder, CO, 80303, USA
| |
Collapse
|
23
|
Preparation and characterization of a novel silicon-modified nanobubble. PLoS One 2017; 12:e0178031. [PMID: 28557995 PMCID: PMC5448765 DOI: 10.1371/journal.pone.0178031] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 05/08/2017] [Indexed: 01/05/2023] Open
Abstract
Nanobubbles (NBs) opened a new field of ultrasound imaging. There is still no practical method to control the diameter of bubbles. In this study, we developed a new method to control the size by incorporating of silicon hybrid lipids into the bubble membrane. The range of particle size of resulting NBs is between 523.02 ± 46.45 to 857.18 ± 82.90, smaller than the conventional microbubbles. The size of resulting NBs increased with the decrease in amount of silicon hybrid lipids, indicating the diameter of NBs can be regulated through modulating the ratio of silicon hybrid lipids in the bubble shell. Typical harmonic signals could be detected. The in vitro and in vivo ultrasound imaging experiments demonstrated these silicon-modified NBs had significantly improved ultrasound contrast enhancement abilities. Cytotoxicity assays revealed that these NBs had no obvious cytotoxicity to the 293 cell line at the tested bubble concentration. Our results showed that the novel NBs could use as nanoscale ultrasound contrast agents, providing the foundation for NBs in future applications including contrast-enhanced imaging and drug/gene delivery.
Collapse
|