1
|
Duan H, Zhao L, Wang J, Wang X, Zheng L, Huang X. Integrating lateral flow device with controllable gold in situ growth for sensitive detection of staphylococcal enterotoxin A in milk. Anal Chim Acta 2024; 1329:343233. [PMID: 39396296 DOI: 10.1016/j.aca.2024.343233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 08/19/2024] [Accepted: 09/09/2024] [Indexed: 10/15/2024]
Abstract
Gold nanoparticle-based lateral flow immunoassays (AuNP-LFIA) are widely used for pathogen monitoring to prevent foodborne illness outbreaks. However, conventional AuNP-LFIA exhibits poor sensitivity and limited quantitative capacity due to the low colorimetric signal intensity of AuNPs. Herein, we introduced a low-background gold in situ growth (GISG) strategy by lowering the pH of the growth solution to weaken the reducibility of hydroxylamine, thereby enhancing the sensitivity of AuNP-LFIA. Additionally, we developed a universal and manufacturable lateral flow device to streamline the GISG process. We applied this device to detect staphylococcal enterotoxin A (SEA), an exotoxin produced by Staphylococcus aureus. Under optimal conditions, the proposed device demonstrated superior practicality and excellent sensitivity for SEA detection, achieving a detection limit of 0.061 ng/mL with the total detection time of 37 min, showing 311 times more sensitive than the unamplified AuNP-LFIA. Furthermore, SEA detection in milk samples showed a strong correlation (R2 = 0.8845) with results obtained from a conventional ELISA kit. Therefore, this promising LFIA device offers a novel strategy with high sensitivity and practicality for in-field detection of Staphylococcus aureus and can be easily adapted for screening other foodborne pathogens.
Collapse
Affiliation(s)
- Hong Duan
- Key Laboratory of Geriatric Nutrition and Health, Ministry of Education, Beijing Technology & Business University, Beijing, 100048, PR China
| | - Lirong Zhao
- Key Laboratory of Geriatric Nutrition and Health, Ministry of Education, Beijing Technology & Business University, Beijing, 100048, PR China
| | - Jiali Wang
- Key Laboratory of Geriatric Nutrition and Health, Ministry of Education, Beijing Technology & Business University, Beijing, 100048, PR China
| | - Xue Wang
- Key Laboratory of Geriatric Nutrition and Health, Ministry of Education, Beijing Technology & Business University, Beijing, 100048, PR China
| | - Lingyan Zheng
- Key Laboratory of Geriatric Nutrition and Health, Ministry of Education, Beijing Technology & Business University, Beijing, 100048, PR China.
| | - Xiaolin Huang
- State Key Laboratory of Food Science and Resources, School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China.
| |
Collapse
|
2
|
Lin M, Yang H, Li Q, Xiao H, Jiang S, Liang J, Cui X, Zhao S. Dual lateral flow assay based on PdRu nanocages for human Papillomavirus detection. J Colloid Interface Sci 2024; 673:893-900. [PMID: 38908288 DOI: 10.1016/j.jcis.2024.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 05/21/2024] [Accepted: 06/02/2024] [Indexed: 06/24/2024]
Abstract
Cervical cancer is one of the most common gynecological malignancies, with the vast majority of which being caused by persistent infection with Human Papillomavirus (HPV) 16 and 18. The current available HPV detection methods are sensitive and genotyped but are restricted by expensive instruments and skilled personnel. The development of an easy-to-use, rapid, and cost-friendly analysis method for HPV is of great need. Herein, hollow palladium-ruthenium nanocages modified with two oligonucleotides (PdRu capture probes) were constructed for genotyping and simultaneous detection of target nucleic acids HPV16 and HPV18 by dual lateral flow assay (DLFA). PdRu capture probes were endowed with bi-functions for the first time, which could be used to output signals and hybridize target nucleic acids. Under optimized conditions, the PdRu based-DLFA with detection limits of 0.93 nM and 0.19 nM, respectively, exhibited convenient operation, and high sensitivity. Meanwhile, the DLFA achieved excellent rapid detection within 20 min, which was attributed to capture probes that can be directly bound to amplification-free target nucleic acids. Therefore, the development of PdRu-based DLFA can be utilized for rapid, sensitive, and simultaneous genotyping detection of HPV16 and HPV18, showing great application for nucleic acid detection.
Collapse
Affiliation(s)
- Mingxia Lin
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Huiyi Yang
- Molecular Diagnosis and Treatment Center for Infectious Diseases, Dermatology Hospital, Southern Medical University, Guangzhou, China.
| | - Qinglan Li
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Huanxin Xiao
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Shilin Jiang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Jinhui Liang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Xiping Cui
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| | - Suqing Zhao
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| |
Collapse
|
3
|
Atta S, Zhao Y, Sanchez S, Seedial D, Devadhasan JP, Summers AJ, Gates-Hollingsworth MA, Pflughoeft KJ, Gu J, Montgomery DC, AuCoin DP, Zenhausern F, Vo-Dinh T. Plasmonic-Enhanced Colorimetric Lateral Flow Immunoassays Using Bimetallic Silver-Coated Gold Nanostars. ACS APPLIED MATERIALS & INTERFACES 2024; 16:54907-54918. [PMID: 39342509 DOI: 10.1021/acsami.4c13086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/01/2024]
Abstract
The colorimetric lateral flow immunoassay (cLFIA) has gained widespread attention as a point-of-care testing (POCT) technique due to its low cost, short analysis time, portability, and capability of being performed by unskilled operators with minimal requirement of reagents. However, the low analytical sensitivity of conventional LFIA based on colloidal gold nanospheres limits their applications for sensitive detection of trace amounts of target analytes. In this study, we introduced a novel plasmonic-enhanced colorimetric LFIA (PE-cLFIA) platform featuring bimetallic silver-coated gold nanostars (BGNS) with exceptional optical properties, leading to ultrahigh visual color brightness. The BGNS-based PE-cLFIA was successfully applied to detect a model analyte, low-calcium response V (LcrV), a virulence protein factor found in Yersinia pestis, the causative agent of bubonic plague. The PE-cLFIA sensing using BGNS-3 composed of 45 nm silver thickness showed a high visual colorimetric sensitivity with a detection limit as low as 13.7 pg/mL, which was around 50 times more sensitive than that of a traditional gold nanoparticle-based LFIA. In addition, the antibody-conjugated BGNS-3 showed excellent stability over 6 months. To illustrate the potential for clinical applications, we demonstrated that our LFIA platform for detecting LcrV spiked in human serum without any sample preprocessing exhibited a detection limit of 22.8 pg/mL. These results open up new opportunities for developing hybrid nanoparticle systems for sensitive POCT PE-cLFIA screening for infectious disease detection.
Collapse
Affiliation(s)
- Supriya Atta
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Yuanhao Zhao
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Sebastian Sanchez
- Department of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Deven Seedial
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Jasmine Pramila Devadhasan
- Center for Applied Nano Bioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | - Alexander Jarrett Summers
- Center for Applied Nano Bioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | | | - Kathryn J Pflughoeft
- Department of Microbiology and Immunology, University of Nevada, Reno School of Medicine, Reno, Nevada 89557, United States
| | - Jian Gu
- Center for Applied Nano Bioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
- Department of Basic Medical Sciences, The University of Arizona, College of Medicine, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - Douglas C Montgomery
- Center for Applied Nano Bioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
- School of Computing and Augmented Intelligence, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, Arizona 85281, United States
| | - David P AuCoin
- Department of Microbiology and Immunology, University of Nevada, Reno School of Medicine, Reno, Nevada 89557, United States
| | - Frederic Zenhausern
- Center for Applied Nano Bioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
- Department of Basic Medical Sciences, The University of Arizona, College of Medicine, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - Tuan Vo-Dinh
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
- Department of Chemistry, Duke University, Durham, North Carolina 27708, United States
| |
Collapse
|
4
|
Liu S, Liao Y, Shu R, Sun J, Zhang D, Zhang W, Wang J. Evaluation of the Multidimensional Enhanced Lateral Flow Immunoassay in Point-of-Care Nanosensors. ACS NANO 2024; 18:27167-27205. [PMID: 39311085 DOI: 10.1021/acsnano.4c06564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/09/2024]
Abstract
Point-of-care (POC) nanosensors with high screening efficiency show promise for user-friendly manipulation in the ever-increasing on-site analysis demand for illness diagnosis, environmental monitoring, and food safety. Currently, inspired by the merits of integrating advanced nanomaterials, molecular biology, machine learning, and artificial intelligence, lateral flow immunoassay (LFIA)-based POC nanosensors have been devoted to satisfying the commercial demands in terms of sensitivity, specificity, and practicality. Herein, we examine the use of multidimensional enhanced LFIA in various fields over the past two decades, focusing on introducing advanced nanomaterials to improve the acquisition capability of small order of magnitude targets through engineering transformations and emphasizing interdomain fusion to collaboratively address the inherent challenges in current commercial applications, such as multiplexing, development of detectors for quantitative analysis, more practical on-site monitoring, and sensitivity enhancement. Specifically, this comprehensive review encompasses the latest advances in comprehending LFIA with an alternative signal transduction pattern, aiming to achieve rapid, ultrasensitive, and "sample-to-answer" available options with progressive applications for POC nanosensors. In summary, through the cross-collaboration development of disciplines, LFIA has the potential to break the barriers toward commercialization and achieve laboratory-level POC nanosensors, thus leading to the emergence of the next generation of LFIA.
Collapse
Affiliation(s)
- Sijie Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Yangjun Liao
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Rui Shu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Jing Sun
- Qinghai Key Laboratory of Qinghai-Tibet Plateau Biological Resources, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining, Qinghai 810008, China
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Wentao Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China
| |
Collapse
|
5
|
Gao F, Wu Y, Gan C, Hou Y, Deng D, Yi X. Overview of the Design and Application of Photothermal Immunoassays. SENSORS (BASEL, SWITZERLAND) 2024; 24:6458. [PMID: 39409498 PMCID: PMC11479306 DOI: 10.3390/s24196458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2024] [Revised: 10/03/2024] [Accepted: 10/04/2024] [Indexed: 10/20/2024]
Abstract
Developing powerful immunoassays for sensitive and real-time detection of targets has always been a challenging task. Due to their advantages of direct readout, controllable sensing, and low background interference, photothermal immunoassays have become a type of new technology that can be used for various applications such as disease diagnosis, environmental monitoring, and food safety. By modification with antibodies, photothermal materials can induce temperature changes by converting light energy into heat, thereby reporting specific target recognition events. This article reviews the design and application of photothermal immunoassays based on different photothermal materials, including noble metal nanomaterials, carbon-based nanomaterials, two-dimensional nanomaterials, metal oxide and sulfide nanomaterials, Prussian blue nanoparticles, small organic molecules, polymers, etc. It pays special attention to the role of photothermal materials and the working principle of various immunoassays. Additionally, the challenges and prospects for future development of photothermal immunoassays are briefly discussed.
Collapse
Affiliation(s)
- Fengli Gao
- Henan Province Key Laboratory of New Opto-Electronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang 455000, China; (F.G.); (Y.W.); (C.G.); (Y.H.)
| | - Yike Wu
- Henan Province Key Laboratory of New Opto-Electronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang 455000, China; (F.G.); (Y.W.); (C.G.); (Y.H.)
| | - Cui Gan
- Henan Province Key Laboratory of New Opto-Electronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang 455000, China; (F.G.); (Y.W.); (C.G.); (Y.H.)
| | - Yupeng Hou
- Henan Province Key Laboratory of New Opto-Electronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang 455000, China; (F.G.); (Y.W.); (C.G.); (Y.H.)
| | - Dehua Deng
- Henan Province Key Laboratory of New Opto-Electronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang 455000, China; (F.G.); (Y.W.); (C.G.); (Y.H.)
| | - Xinyao Yi
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China
| |
Collapse
|
6
|
Khatmi G, Klinavičius T, Simanavičius M, Silimavičius L, Tamulevičienė A, Rimkutė A, Kučinskaitė-Kodzė I, Gylys G, Tamulevičius T. Lateral flow assay sensitivity and signal enhancement via laser µ-machined constrains in nitrocellulose membrane. Sci Rep 2024; 14:22936. [PMID: 39358489 PMCID: PMC11446913 DOI: 10.1038/s41598-024-74407-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Accepted: 09/25/2024] [Indexed: 10/04/2024] Open
Abstract
Lateral flow assay (LFA) is a handful diagnostic technology that can identify severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other common respiratory viruses in one strip, which can be tested at the point-of-care without the need for equipment or skilled personnel outside the laboratory. Although its simplicity and practicality make it an appealing solution, it remains a grand challenge to substantially enhance the colorimetric LFA sensitivity. In this work, we present a straightforward approach to enhance the sensitivity of LFA by imposing the flow constraints in nitrocellulose (NC) membranes via a number of vertical femtosecond laser micromachined microchannels which is important for prolonged specific binding interactions. Porous NC membrane surfaces were structured with different widths and densities µ-channels employing a second harmonic of the Yb:KGW femtosecond laser and sample XYZ translation over a microscope objective-focused laser beam. The influence of the microchannel parameters on the vertical wicking speed was evaluated from the video recordings. The obtained results indicated that µ-channel length, width, and density in NC membranes controllably increased the immunological reaction time between the analyte and the labeled antibody by 950%. Image analysis of the colorimetric indicators confirmed that the flow rate delaying strategy enhanced the signal sensitives by 40% compared with pristine NC LFA.
Collapse
Affiliation(s)
- Gazy Khatmi
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania.
| | - Tomas Klinavičius
- Institute of Materials Science, Kaunas University of Technology, Kaunas, Lithuania
| | - Martynas Simanavičius
- Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Laimis Silimavičius
- UAB Sanpharm, Vilnius, Lithuania
- Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Asta Tamulevičienė
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania
- Institute of Materials Science, Kaunas University of Technology, Kaunas, Lithuania
| | - Agnė Rimkutė
- Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | | | | | - Tomas Tamulevičius
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania.
- Institute of Materials Science, Kaunas University of Technology, Kaunas, Lithuania.
| |
Collapse
|
7
|
Xu X, Yue S, Tu K, Yuan B, Bi S, Yu J, Qiu H, Zhang H, Zhang L, Wu HF, Chen XJ, Zhao S, Zhang W, Zhang JN, Jiang LP, Zhang JR, Zhu JJ. Multi-Shell Nanourchin-Integrated Dual Mode Lateral Flow Immunoassay for Sensitive and Rapid Detection of Clinical Cardiac Myosin-Binding Protein C. Anal Chem 2024; 96:11853-11861. [PMID: 38989993 DOI: 10.1021/acs.analchem.4c01514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/12/2024]
Abstract
Cardiac myosin-binding protein C (cMyBP-C) is a novel cardiac marker of acute myocardial infarction (AMI) and acute cardiac injuries (ACI). Construction of point-of-care testing techniques capable of sensing cMyBP-C with high sensitivity and precision is urgently needed. Herein, we synthesized an Au@NGQDs@Au/Ag multi-shell nanoUrchins (MSNUs), and then applied it in a colorimetric/SERS dual-mode immunoassay for detection of cMyBP-C. The MSNUs displayed superior stability, colorimetric brightness, and SERS enhancement ability with an enhanced factor of 5.4 × 109, which were beneficial to improve the detection capability of test strips. The developed MSNU-based test strips can achieve an ultrasensitive immunochromatographic assay of cMyBP-C in both colorimetric and SERS modes with the limits of detection as low as 19.3 and 0.77 pg/mL, respectively. Strikingly, this strip was successfully applied to analyze actual plasma samples with significantly better sensitivity, negative predictive value, and accuracy than commercially available gold test strips. Notably, this method possessed a wide range of application scenarios via combining with a color recognizer application named Color Grab on the smartphone, which can meet various needs of different users. Overall, our MSNU-based test strip as a mobile health monitoring tool shows excellent sensitivity, reproducibility, and rapid detection of the cMyBP-C, which holds great potential for the early clinic diagnosis of AMI and ACI.
Collapse
Affiliation(s)
- Xuan Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Shuzhen Yue
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Keke Tu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Baozhen Yuan
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Sai Bi
- College of Chemistry and Chemical Engineering, Key Laboratory of Shandong Provincial Universities for Functional Molecules and Materials, Qingdao University, Qingdao 266071, P. R. China
| | - Jinjin Yu
- Nanjing Bottests Biotech CO., LTD, Nanjing 211112, P. R. China
| | - Hui Qiu
- Nanjing Bottests Biotech CO., LTD, Nanjing 211112, P. R. China
| | - Haotian Zhang
- Nanjing Bottests Biotech CO., LTD, Nanjing 211112, P. R. China
| | - Lei Zhang
- Nanjing Bottests Biotech CO., LTD, Nanjing 211112, P. R. China
| | - Heng-Fang Wu
- Institute of Cardiovascular Disease, First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - Xiang-Jian Chen
- Institute of Cardiovascular Disease, First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - Sheng Zhao
- Institute of Cardiovascular Disease, First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - Wei Zhang
- Institute of Cardiovascular Disease, First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - Ji-Nan Zhang
- Institute of Cardiovascular Disease, First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, P. R. China
| | - Li-Ping Jiang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Jian-Rong Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Jun-Jie Zhu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| |
Collapse
|
8
|
Gao F, Ye S, Huang L, Gu Z. A nanoparticle-assisted signal-enhancement technique for lateral flow immunoassays. J Mater Chem B 2024; 12:6735-6756. [PMID: 38920348 DOI: 10.1039/d4tb00865k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
Lateral flow immunoassay (LFIA), an affordable and rapid paper-based detection technology, is employed extensively in clinical diagnosis, environmental monitoring, and food safety analysis. The COVID-19 pandemic underscored the validity and adoption of LFIA in performing large-scale clinical and public health testing. The unprecedented demand for prompt diagnostic responses and advances in nanotechnology have fueled the rise of next-generation LFIA technologies. The utilization of nanoparticles to amplify signals represents an innovative approach aimed at augmenting LFIA sensitivity. This review probes the nanoparticle-assisted amplification strategies in LFIA applications to secure low detection limits and expedited response rates. Emphasis is placed on comprehending the correlation between the physicochemical properties of nanoparticles and LFIA performance. Lastly, we shed light on the challenges and opportunities in this prolific field.
Collapse
Affiliation(s)
- Fang Gao
- Institute of Energy Materials Science, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
| | - Shaonian Ye
- Institute of Energy Materials Science, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
| | - Lin Huang
- Department of Clinical Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China.
- Shanghai Institute of Thoracic Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China
| | - Zhengying Gu
- Department of Clinical Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China.
- Shanghai Institute of Thoracic Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China
| |
Collapse
|
9
|
Konziw S, Tunakhun P, Ngernpimai S, Srichaiyapol O, Boonsiri P, Tippayawat P, Techasen A, Maraming P, Choowongkomon K, Daduang S, Promdee L, Daduang J. Development in competitive immunoassay of a point-of-care testing for cotinine (COT) detection in urine. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:4387-4394. [PMID: 38899527 DOI: 10.1039/d4ay00518j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/21/2024]
Abstract
We present a sensitive and selective lateral flow immunoassay (LFIA) for cotinine (COT), the primary metabolite of nicotine. COT is widely recognized as a superior biomarker to evaluate tobacco smoke exposure. The LFIA uses a competitive assay format where the COT-BSA capture competes with the target COT in urine samples for binding to the monoclonal antibody against COT (mAb-COT) conjugated with gold nanoparticles (mAb-COT-AuNPs). To improve the sensitivity and selectivity of the LFIA-COT, we focused on optimizing the diameter of AuNPs, the conjugation of mAb-COT, and the concentration of the COT-BSA capture. Our findings reveal that the utilization of 40 nm AuNPs in conjugation with a concentration of 4 mg mL-1 of mAb-COT demonstrated significantly greater efficacy compared to LFAs utilizing 20 nm AuNPs. Under the optimal conditions, the LFIA-COT demonstrated sensitive detection of COT at a level of 150 ng mL-1 within 15 min, as observed by the naked eye. It possesses a linear range of 25 to 200 ng mL-1 of COT, with the limit of detection (LOD) of 11.94 ng mL-1 in human urine samples when the color intensity is analyzed using ImageJ software. Our LFIA described here is simple and requires less time for COT detection. It can be used for the rapid and quantitative detection of COT in urine samples in clinical settings.
Collapse
Affiliation(s)
- Suthinee Konziw
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences (CMDL), Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Paweena Tunakhun
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences (CMDL), Khon Kaen University, Khon Kaen, 40002, Thailand
- Biomedical Sciences, Graduate School, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Sawinee Ngernpimai
- Centre for Innovation and Standard for MT and PT (CISMaP), Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Oranee Srichaiyapol
- Centre for Innovation and Standard for MT and PT (CISMaP), Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Patcharee Boonsiri
- Department of Biochemistry, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Patcharaporn Tippayawat
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences (CMDL), Khon Kaen University, Khon Kaen, 40002, Thailand
- Department of Medical Technology, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen, 40002, Thailand.
| | - Anchalee Techasen
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences (CMDL), Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Pornsuda Maraming
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences (CMDL), Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Kiattawee Choowongkomon
- Department of Biochemistry, Faculty of Science, Kasetsart University, Phahonyothin Road, Chatuchak, Bangkok, 10900, Thailand
| | - Sakda Daduang
- Division of Pharmacognosy and Toxicology, Faculty of Pharmaceutical Sciences, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Limthong Promdee
- Department of Medical Technology, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen, 40002, Thailand.
| | - Jureerut Daduang
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences (CMDL), Khon Kaen University, Khon Kaen, 40002, Thailand
- Department of Medical Technology, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen, 40002, Thailand.
| |
Collapse
|
10
|
Chu J, Zhang Y, Li J, Hong J, Sun L, Wei J. A separation-free paper-based hydrogel device for one-step reactive oxygen species determination by a smartphone. J Mater Chem B 2024. [PMID: 38957936 DOI: 10.1039/d4tb00715h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
Paper-based analytical devices (PADs) are very convenient for determining biomarkers in point-of-care (POC) diagnosis while requiring sample pre-treatment or impurity separation. This study reports a novel hydrogel-coupled, paper-based analytical device (PAD) for separation-free H2O2 colorimetric detection in both aqueous solution and cell lysis with sample-to-answer analysis by directly loading into the sample test zone. By encapsulating an inorganic mimic enzyme and chromogenic substrate into the sodium alginate (SA) hydrogel, amplification of the color signal after catalyzing the substrate could be achieved. Taking advantage of the nanoscale porous structure of the hydrogel and the lateral flow channel of the PAD, large interference fragments or bio-macromolecules are prevented from diffusing into the chromogenic reaction, whereas the small target molecules enter the sensing region to trigger the catalytic reaction. This method demonstrated a rapid and accurate analysis with a limit of detection as low as 0.06 mM and detection selectivity. Our proposed device requires no enzyme and is separation-free, portable, easy-to-fabricate, and low-cost, and may offer a platform for quantitative or qualitative analysis of other analytes in body fluids for POC applications.
Collapse
Affiliation(s)
- Jie Chu
- School of Life Sciences, Henan University, Kaifeng, Henan, 475004, China.
- School of Physical Education and Sport, Henan University, Kaifeng, Henan, 475004, China
| | - Yiyi Zhang
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan, 475004, China.
| | - Jingwen Li
- School of Life Sciences, Henan University, Kaifeng, Henan, 475004, China.
- School of Physical Education and Sport, Henan University, Kaifeng, Henan, 475004, China
| | - Jun Hong
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan, 475004, China.
| | - Lin Sun
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan, 475004, China.
| | - Jianshe Wei
- School of Life Sciences, Henan University, Kaifeng, Henan, 475004, China.
- School of Physical Education and Sport, Henan University, Kaifeng, Henan, 475004, China
| |
Collapse
|
11
|
Liu S, Shu R, Zhao C, Sun C, Zhang M, Wang S, Li B, Dou L, Ji Y, Wang Y, Zhang D, Wang Z, Wang J. Precise Spectral Overlap-Based Donor-Acceptor Pair for a Sensitive Traffic Light-Typed Bimodal Multiplexed Lateral Flow Immunoassay. Anal Chem 2024; 96:5046-5055. [PMID: 38488055 DOI: 10.1021/acs.analchem.4c00881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
Bimodal-type multiplexed immunoassays with complementary mode-based correlation analysis are gaining increasing attention for enhancing the practicability of the lateral flow immunoassay (LFIA). Nonetheless, the restriction in visually indistinguishable multitargets induced by a single fluorescent color and difficulty in single acceptor ineffectual fluorescence quenching due to the various spectra of multiple different donors impede the further execution of colorimetric-fluorescence bimodal-type multiplexed LFIAs. Herein, the precise spectral overlap-based donor-acceptor pair construction strategy is proposed by regulating the size of the nanocore, coating it with an appropriate nanoshell, and selecting a suitable fluorescence donor with distinct colors. By in situ coating Prussian blue nanoparticles (PBNPs) on AuNPs with a tunable size and absorption spectrum, the resultant APNPs demonstrate efficient fluorescence quenching ability, higher colloidal stability, remarkable colorimetric intensity, and an enhanced antibody coupling efficiency, all of which facilitate highly sensitive bimodal-type LFIA analysis. Following integration with competitive-type immunoreaction, this precise spectral overlap-supported spatial separation traffic light-typed colorimetric-fluorescence dual-response assay (coined as the STCFD assay) with the limits of detection of 0.013 and 0.152 ng mL-1 for ractopamine and clenbuterol, respectively, was proposed. This work illustrates the superiority of the rational design of a precise spectral overlap-based donor-acceptor pair, hinting at the enormous potential of the STCFD assay in the point-of-care field.
Collapse
Affiliation(s)
- Sijie Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Rui Shu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Cong Zhao
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Chenyang Sun
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Mingrui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Shaochi Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Bingzhi Li
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Leina Dou
- National Key Laboratory of Veterinary Public Health Security, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
| | - Yanwei Ji
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Yanru Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Zhanhui Wang
- National Key Laboratory of Veterinary Public Health Security, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| |
Collapse
|
12
|
Atta S, Zhao Y, Li JQ, Vo-Dinh T. Dual-Modal Colorimetric and Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunoassay for Ultrasensitive Detection of SARS-CoV-2 Using a Plasmonic Gold Nanocrown. Anal Chem 2024; 96:4783-4790. [PMID: 38471066 DOI: 10.1021/acs.analchem.3c04361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
The 2019 coronavirus disease (COVID-19) outbreak created an unprecedented need for rapid, sensitive, and cost-effective point-of-care diagnostic tests to prevent and mitigate the spread of the SARS-CoV-2 virus. Herein, we demonstrated an advanced lateral flow immunoassay (LFIA) platform with dual-functional [colorimetric and surface-enhanced Raman scattering (SERS)] detection of the spike 1 (S1) protein of SARS-CoV-2. The nanosensor was integrated with a specially designed core-gap-shell morphology consisting of a gold shell decorated with external nanospheres, a structure referred to as gold nanocrown (GNC), labeled with a Raman reporter molecule 1,3,3,1',3',3'-hexamethyl-2,2'-indotricarbocyanine iodide (HITC) to produce a strong colorimetric signal as well as an enhanced SERS signal. Among the different plasmonics-active GNC nanostructures, the GNC-2 morphology, which has a shell decorated with an optimum number and size of nanospheres, produces an intense dark-blue colorimetric signal and ultrahigh SERS signal. The limit of detection (LOD) of the S1 protein via colorimetric detection LFIA was determined to be 91.24 pg/mL. On the other hand, the LOD for the SERS LFIA method was more than three orders of magnitude lower at 57.21 fg/mL. Furthermore, we analyzed the performance of the GNC-2 nanosensor for directly analyzing the S1 protein spiked in saliva samples without any sample pretreatment and achieving the LOD as low as 39.65 fg/mL using SERS-based plasmonics-enhanced LFIA, indicating ultrahigh detection sensitivity. Overall, our GNC nanosensor showed excellent sensitivity, reproducibility, and rapid detection of the SARS-CoV-2 S1 protein, demonstrating excellent potential as a promising point-of-care platform for the early detection of respiratory virus infections.
Collapse
Affiliation(s)
- Supriya Atta
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Yuanhao Zhao
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Joy Qiaoyi Li
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Tuan Vo-Dinh
- Fitzpatrick Institute for Photonics, Duke University, Durham, North Carolina 27708, United States
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
- Department of Chemistry, Duke University, Durham, North Carolina 27708, United States
| |
Collapse
|
13
|
Gao S, Niu L, Zhou R, Wang C, Zheng X, Zhang D, Huang X, Guo Z, Zou X. Significance of the antibody orientation for the lateral flow immunoassays: A mini-review. Int J Biol Macromol 2024; 257:128621. [PMID: 38070797 DOI: 10.1016/j.ijbiomac.2023.128621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 12/01/2023] [Accepted: 12/02/2023] [Indexed: 01/26/2024]
Abstract
Lateral flow immunoassays (LFIAs) are well-established and broadly commercialized tools in the field of point-of-care testing due to their simplicity, rapidity, cost-effectiveness, and low requirements for users and equipment. However, the insensitivity and the possibility of producing inaccurate results associated with conventional LFIAs have impeded their wide-ranging implementation, especially for monitoring ultra-trace level of analytes. Moreover, the heterogeneous distribution of amino acids on the surface of antibody (Ab) results in a lack of precise control over their orientation, which ultimately leads to unsatisfactory detection performance. To address those concerns, herein we provide an overview of the emerging efforts to prepare well-established LFIAs from the perspective of orientation manipulation of immobilized Abs on the nanoprobes or membranes. The preparation of excellent nanoprobes with Abs being oriented immobilized, consisting of the nanoprobe types, Ab types, and their conjugation chemistries, are reviewed. Followed by the introduction of efforts highlight the importance of directionally immobilized Ab on the membrane. The effects of Ab orientation on the analytical performance of LFIA platforms in terms of sensitivity, specificity, rapidity, reliability, cost-effectiveness, and stability are also summarized. Finally, the future development and challenges of Ab-oriented immobilization-assisted LFIAs are also discussed.
Collapse
Affiliation(s)
- Shipeng Gao
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Lidan Niu
- Key Laboratory of Condiment Supervision Technology for State Market Regulation, Chongqing Institute for Food and Drug Control, Chongqing 401121, China
| | - Ruiyun Zhou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Chen Wang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Xueyun Zheng
- Key Laboratory of Fermentation Engineering (Ministry of Education), School of Biological Engineering and Food, Hubei University of Technology, Wuhan 430068, China
| | - Di Zhang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Xianliang Huang
- Key Laboratory of Condiment Supervision Technology for State Market Regulation, Chongqing Institute for Food and Drug Control, Chongqing 401121, China
| | - Zhiming Guo
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; International Joint Research Laboratory of Intelligent Agriculture and Agri-products Processing (Jiangsu University), Jiangsu Education Department, Zhenjiang 212013, China.
| | - Xiaobo Zou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China; China Light Industry Key Laboratory of Food Intelligent Detection & Processing, Jiangsu University, Zhenjiang 212013, China
| |
Collapse
|
14
|
Liu S, Shu R, Zhang M, Zhao C, Wang K, Zhang J, Sun J, Dou L, Zhang D, Wang J. Goat anti-mouse immunoglobulin as "crosslinker" assisted signal tracer assemble with intensive antibody utilization efficiency for sensitive paper-based strip nanobiosensors. Int J Biol Macromol 2024; 258:128923. [PMID: 38151088 DOI: 10.1016/j.ijbiomac.2023.128923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/11/2023] [Accepted: 12/18/2023] [Indexed: 12/29/2023]
Abstract
Engineered collaborative biochemical techniques and regulated nanomaterials (NMs) offer extraordinary opportunities for improving the analysis performance of lateral flow immunoassay (LFIA). Herein, inspired by the ability of macromolecules (e.g., proteins) to assemble into new functional units and the remarkable optical performance of engineered regulated NMs, goat anti-mouse immunoglobulin (GAMI) serves as the "crosslinker" integrate with gold‑manganese oxide (Au-MnOx) to assemble the "signal tracers (STs)-crosslinker-antibody (mAb)" for elevating the mAb utilization efficiency. Notably, the "STs-crosslinker-mAb" assembly shows ~13.33-folds mAb utilization efficiency enhance, which perfectly response the challenge between limited sensitivity and sufficient signal intensity in competitive-type LFIA. The black color and rough structure of Au-MnOx offer higher colorimetric brightness (~2-folds than AuNPs) and enhanced mAb coupling efficiency (up to 92.47%), which further improves sensitivity under the premise of functional assembly to intensify the competitive immunoreaction. Additionally, the convenient synthesis conditions (~13 min at room temperature) even comparable to direct purchase commercial products indicate that using Au-MnOx undoubtedly increases the cost-effectiveness. Encouragingly, the Au-MnOx-GAMI-mAb based LFIA exhibited high sensitivity (LOD: 0.063 ng mL-1 for clenbuterol (CLE) monitoring) by elevating mAb utilization efficiency with the attendant enhancing immune competition response in a cost-effective manner, which provides an invigorating reference pathway in point-of-care immunoassay.
Collapse
Affiliation(s)
- Sijie Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Rui Shu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Mingrui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Cong Zhao
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Kexin Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Jiayi Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Jing Sun
- Qinghai Key Laboratory of Qinghai-Tibet Plateau Biological Resources, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining 810008, Qinghai, China
| | - Leina Dou
- College of veterinary medicine, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
| |
Collapse
|
15
|
Meng X, Zuo W, Wu P, Song Y, Yang GJ, Zhang S, Yang J, Zou X, Wei W, Zhang D, Dai J, Ju Y. Bimetallic Nanozyme: A Credible Tag for In Situ-Catalyzed Reporter Deposition in the Lateral Flow Immunoassay for Ultrasensitive Cancer Diagnosis. NANO LETTERS 2024; 24:51-60. [PMID: 37823474 DOI: 10.1021/acs.nanolett.3c03118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
The lateral flow immunoassay (LFIA) is a sought-after point-of-care testing platform, yet the insufficient sensitivity of the LFIA limits its application in the detection of tumor biomarkers. Here, a colorimetric signal amplification method, bimetallic nanozyme-mediated in situ-catalyzed reporter deposition (BN-ISCRD), was designed for ultrasensitive cancer diagnosis. The bimetallic nanozyme used, palladium@iridium core-shell nanoparticles (Pd@Ir NPs), had ultrahigh enzyme-like activity, which was further explained by the electron transfer of Pd@Ir NPs and the change in the Gibbs free energy during catalysis through density functional theory calculations. With gastric cancer biomarkers pepsinogen I and pepsinogen II as model targets, this assay could achieve a cutoff value of 10 pg/mL, which was 200-fold lower than that without signal enhancement. The assay was applied to correctly identify 8 positive and 28 negative clinical samples. Overall, this BN-ISCRD-based LFIA showed great merits and potential in the application of ultrasensitive disease diagnosis.
Collapse
Affiliation(s)
- Xiangming Meng
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
| | - Wanchao Zuo
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
| | - Pengcheng Wu
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
| | - Yuhan Song
- Nanjing Institute for Food and Drug Control, Nanjing 210038, China
| | - Gong-Jun Yang
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
| | - Shibo Zhang
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
| | - Jun Yang
- Nanjing Institute for Food and Drug Control, Nanjing 210038, China
| | - Xiaopeng Zou
- Zhanjiang Institute of Clinical Medicine, Guangdong Medical University Zhanjiang Central Hospital, Zhanjiang 524045, China
| | - Wenlu Wei
- Zhanjiang Institute of Clinical Medicine, Guangdong Medical University Zhanjiang Central Hospital, Zhanjiang 524045, China
| | - Donghui Zhang
- Zhanjiang Institute of Clinical Medicine, Guangdong Medical University Zhanjiang Central Hospital, Zhanjiang 524045, China
| | - Jianjun Dai
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
- MOE Joint International Research Laboratory of Animal Health and Food Safety, Key Laboratory of Animal Bacteriology, Ministry of Agriculture, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing 210095, China
| | - Yanmin Ju
- College of Pharmacy, China Pharmaceutical University, Nanjing 211198, China
| |
Collapse
|
16
|
Fan L, Yan W, Chen Q, Tan F, Tang Y, Han H, Yu R, Xie N, Gao S, Chen W, Chen Z, Zhang P. One-Component Dual-Readout Aggregation-Induced Emission Nanobeads for Qualitative and Quantitative Detection of C-Reactive Protein at the Point of Care. Anal Chem 2024; 96:401-408. [PMID: 38134291 DOI: 10.1021/acs.analchem.3c04441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
Fluorescent lateral flow immunoassay (LFA) systems are versatile tools for sensitive and quantitative detection of disease markers at the point of care. However, traditional fluorescent nanoparticle-based lateral flow immunoassays are not visible under room light, necessitate an additional fluorescent reader, and lack flexibility for different application scenarios. Herein, we report a dual-readout LFA system for the rapid and sensitive detection of C-reactive protein (CRP) in clinical samples. The system relied on the aggregation-induced emission nanobeads (AIENBs) encapsulated with red AIE luminogen, which possesses both highly fluorescent and colorimetric properties. The AIENB-based LFA in the naked-eye mode was able to qualitatively detect CRP levels as low as 8.0 mg/L, while in the fluorescent mode, it was able to quantitatively measure high-sensitivity CRP (hs-CRP) with a limit of detection of 0.16 mg/L. The AIENB-based LFA system also showed a good correlation with the clinically used immunoturbidimetric method for CRP and hs-CRP detection in human plasma. This dual-modal AIENB-based LFA system offers the convenience of colorimetric testing and highly sensitive and quantitative detection of disease biomarkers and medical diagnostics in various scenarios.
Collapse
Affiliation(s)
- Lingzhi Fan
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| | - Wannian Yan
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| | - Qilong Chen
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| | - Fei Tan
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| | - Yijie Tang
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| | - Huanxing Han
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
| | - Rujia Yu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Ni Xie
- AUISET Biotechnology Co., Ltd., Kwai Chung, New Territories, Hong Kong S.A.R. 000000, China
- AIEgen Biotech Co., Ltd., 28 Yee Wo Street, Causeway Bay, Hong Kong S.A.R. 000000, China
| | - Shouhong Gao
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
| | - Wansheng Chen
- Department of Pharmacy, Changzheng Hospital, Naval Medical University, Shanghai 200003, China
- The SATCM Key Laboratory for New Resources & Quality Evaluation of Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Zhongjian Chen
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
- Shanghai Engineering Research Center for External Chinese Medicine, Shanghai 200433, China
| | - Pengfei Zhang
- Department of Central Laboratory, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai 200443, China
| |
Collapse
|
17
|
Xu K, Zhang S, Zhuang X, Zhang G, Tang Y, Pang H. Recent progress of MOF-functionalized nanocomposites: From structure to properties. Adv Colloid Interface Sci 2024; 323:103050. [PMID: 38086152 DOI: 10.1016/j.cis.2023.103050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/29/2023] [Accepted: 11/06/2023] [Indexed: 01/13/2024]
Abstract
Metal-organic frameworks (MOFs) are novel crystalline porous materials assembled from metal ions and organic ligands. The adaptability of their design and the fine-tuning of the pore structures make them stand out in porous materials. Furthermore, by integrating MOF guest functional materials with other hosts, the novel composites have synergistic benefits in numerous fields such as batteries, supercapacitors, catalysis, gas storage and separation, sensors, and drug delivery. This article starts by examining the structural relationship between the host and guest materials, providing a comprehensive overview of the research advancements in various types of MOF-functionalized composites reported to date. The review focuses specifically on four types of spatial structures, including MOFs being (1) embedded in nanopores, (2) immobilized on surface, (3) coated as shells and (4) assembled into hybrids. In addition, specific design ideas for these four MOF-based composites are presented. Some of them involve in situ synthesis method, solvothermal method, etc. The specific properties and applications of these materials are also mentioned. Finally, a brief summary of the advantages of these four types of MOF composites is given. Hopefully, this article will help researchers in the design of MOF composite structures.
Collapse
Affiliation(s)
- Kun Xu
- School of Chemistry and Chemical Engineering, Testing Center, Yangzhou University, Yangzhou 225009, PR China
| | - Songtao Zhang
- School of Chemistry and Chemical Engineering, Testing Center, Yangzhou University, Yangzhou 225009, PR China
| | - Xiaoli Zhuang
- School of Chemistry and Chemical Engineering, Testing Center, Yangzhou University, Yangzhou 225009, PR China
| | - Guangxun Zhang
- School of Chemistry and Chemical Engineering, Testing Center, Yangzhou University, Yangzhou 225009, PR China
| | - Yijian Tang
- School of Chemistry and Chemical Engineering, Testing Center, Yangzhou University, Yangzhou 225009, PR China
| | - Huan Pang
- School of Chemistry and Chemical Engineering, Testing Center, Yangzhou University, Yangzhou 225009, PR China.
| |
Collapse
|
18
|
Gupta R, Gupta P, Wang S, Melnykov A, Jiang Q, Seth A, Wang Z, Morrissey JJ, George I, Gandra S, Sinha P, Storch GA, Parikh BA, Genin GM, Singamaneni S. Ultrasensitive lateral-flow assays via plasmonically active antibody-conjugated fluorescent nanoparticles. Nat Biomed Eng 2023; 7:1556-1570. [PMID: 36732621 DOI: 10.1038/s41551-022-01001-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Accepted: 12/20/2022] [Indexed: 02/04/2023]
Abstract
Lateral-flow assays (LFAs) are rapid and inexpensive, yet they are nearly 1,000-fold less sensitive than laboratory-based tests. Here we show that plasmonically active antibody-conjugated fluorescent gold nanorods can make conventional LFAs ultrasensitive. With sample-to-answer times within 20 min, plasmonically enhanced LFAs read out via a standard benchtop fluorescence scanner attained about 30-fold improvements in dynamic range and in detection limits over 4-h-long gold-standard enzyme-linked immunosorbent assays, and achieved 95% clinical sensitivity and 100% specificity for antibodies in plasma and for antigens in nasopharyngeal swabs from individuals with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Comparable improvements in the assay's performance can also be achieved via an inexpensive portable scanner, as we show for the detection of interleukin-6 in human serum samples and of the nucleocapsid protein of SARS-CoV-2 in nasopharyngeal samples. Plasmonically enhanced LFAs outperform standard laboratory tests in sensitivity, speed, dynamic range, ease of use and cost, and may provide advantages in point-of-care diagnostics.
Collapse
Affiliation(s)
- Rohit Gupta
- Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Prashant Gupta
- Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Sean Wang
- Department of Biology, Washington University in St. Louis, St. Louis, MO, USA
| | | | | | - Anushree Seth
- Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Zheyu Wang
- Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Jeremiah J Morrissey
- Department of Anesthesiology, Division of Clinical and Translational Research, Washington University in St. Louis, St. Louis, MO, USA
- Siteman Cancer Center, Washington University School of Medicine, St. Louis, MO, USA
| | - Ige George
- Department of Internal Medicine, Division of Infectious Diseases, Washington University School of Medicine, St. Louis, MO, USA
| | - Sumanth Gandra
- Department of Internal Medicine, Division of Infectious Diseases, Washington University School of Medicine, St. Louis, MO, USA
| | - Pratik Sinha
- Department of Anesthesiology, Division of Clinical and Translational Research, Washington University in St. Louis, St. Louis, MO, USA
| | - Gregory A Storch
- Department of Pediatrics, Washington University School of Medicine, St. Louis, MO, USA
| | - Bijal A Parikh
- Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO, USA
| | - Guy M Genin
- Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, St. Louis, MO, USA
- NSF Science and Technology Center for Engineering MechanoBiology, Washington University in St. Louis, St. Louis, MO, USA
| | - Srikanth Singamaneni
- Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University in St. Louis, St. Louis, MO, USA.
- Siteman Cancer Center, Washington University School of Medicine, St. Louis, MO, USA.
| |
Collapse
|
19
|
Chai F, Wang D, Shi F, Zheng W, Zhao X, Chen Y, Mao C, Zhang J, Jiang X. Dual Functional Ultrasensitive Point-of-Care Clinical Diagnosis Using Metal-Organic Frameworks-Based Immunobeads. NANO LETTERS 2023; 23:9056-9064. [PMID: 37738391 DOI: 10.1021/acs.nanolett.3c02828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/24/2023]
Abstract
Sepsis is an acute systemic infectious syndrome with high fatality. Fast and accurate diagnosis, monitoring, and medication of sepsis are essential. We exploited the fluorescent metal-AIEgen frameworks (MAFs) and demonstrated the dual functions of protein detection and bacteria identification: (i) ultrasensitive point-of-care (POC) detection of sepsis biomarkers (100 times enhanced sensitivity); (ii) rapid POC identification of Gram-negative/positive bacteria (selective aggregation within 20 min). Fluorescent lateral flow immunoassays (LFAs) are convenient and inexpensive for POC tests. MAFs possess a large surface area, excellent photostability, high quantum yield (∼80%), and multiple active sites serving as protein binding domains for ultrasensitive detection of sepsis biomarkers (IL-6/PCT) on LFAs. The limit of detection (LOD) for IL-6/PCT is 0.252/0.333 pg/mL. Rapid appraisal of infectious bacteria is vital to guide the use of medicines. The dual-functional fluorescent MAFs have great potential in POC tests for the clinical diagnosis of bacterial infections.
Collapse
Affiliation(s)
- Fengli Chai
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Dou Wang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Fei Shi
- Shenzhen People's Hospital (The First Affiliated Hospital of Southern University of Science and Technology, The Second Clinical Medical College of Jinan University), Shenzhen, Guangdong 518020, China
| | - Wenfu Zheng
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, National Center for NanoScience and Technology, Beijing 100190, China
| | - Xiaohui Zhao
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Yao Chen
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Cuiping Mao
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Jiangjiang Zhang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
- Key Laboratory of Molecular Medicine and Biotherapy, the Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Xingyu Jiang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
| |
Collapse
|
20
|
Sarathkumar E, Anjana RS, Jayasree RS. Nanoarchitectonics of photothermal materials to enhance the sensitivity of lateral flow assays. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2023; 14:988-1003. [PMID: 37822722 PMCID: PMC10562646 DOI: 10.3762/bjnano.14.82] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 09/14/2023] [Indexed: 10/13/2023]
Abstract
Lateral flow assays (LFAs) are currently the most widely used point-of-care testing technique with remarkable advantages such as simple operation, rapid analysis, portability, and low cost. Traditionally, gold nanoparticles are employed as tracer element in LFAs due to their strong localised surface plasmon resonance. However, this conventional LFA technique based on colorimetric analysis is neither useful to determine critical analytes with desired sensitivity, nor can it quantify the analytes. Various signal amplification strategies have been proposed to improve the sensitivity and the quantitative determination of analytes using LFAs. One of the promising strategies is to enhance the photothermal properties of nanomaterials to generate heat after light irradiation, followed by a temperature measurement to detect and quantify the analyte concentration. Recently, it has been observed that the nanoscale architecture of materials, including size, shape, and nanoscale composition, plays a significant role in enhancing the photothermal properties of nanomaterials. In this review, we discuss the nanoarchitectonics of nanomaterials regarding enhanced photothermal properties and their application in LFAs. Initially, we discuss various important photothermal materials and their classification along with their working principle. Then, we highlight important aspects of the nanoscale architecture (i.e., size, shape, and composition) to enable maximum light-to-heat conversion efficiency. Finally, we discuss some of the recent advances in photothermal LFAs and their application in detecting analytes.
Collapse
Affiliation(s)
- Elangovan Sarathkumar
- Division of Biophotonics and Imaging, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojappura, Thiruvananthapuram-695012, Kerala, India
| | - Rajasekharan S Anjana
- Division of Biophotonics and Imaging, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojappura, Thiruvananthapuram-695012, Kerala, India
| | - Ramapurath S Jayasree
- Division of Biophotonics and Imaging, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojappura, Thiruvananthapuram-695012, Kerala, India
| |
Collapse
|
21
|
Liu S, Liao Y, Zhang Y, Shu R, Zhang M, Luo X, Sun C, Dou L, Luo L, Sun J, Zhang D, Zeng L, Wang J. Engineered Collaborative Size Regulation and Shape Engineering of Tremella-Like Au-MnO x for Highly Sensitive Bimodal-Type Lateral Flow Immunoassays. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2301598. [PMID: 37381671 DOI: 10.1002/smll.202301598] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 06/06/2023] [Indexed: 06/30/2023]
Abstract
Engineered collaborative size regulation and shape engineering of multi-functional nanomaterials (NPs) offer extraordinary opportunities for improving the analysis performance. It is anticipated to address the difficulty in distinguishing color changes caused by subtle variations in target concentrations, thereby facilitating the highly sensitive analysis of lateral flow immunoassays (LFIAs). Herein, tremella-like gold-manganese oxide (Au-MnOx ) nanoparticles with precise MnCl2 regulation are synthesized as immuno signal tracers via a facile one-step redox reaction in alkaline condition at ambient temperature. Avail of the tunable elemental composition and anisotropy in morphology, black-colored tremella-like Au-MnOx exhibits superb colorimetric signal brightness, enhanced antibody coupling efficiency, marvelous photothermal performance, and unrestricted immunological recognition affinity, all of which facilitate highly sensitive multi-signal transduction patterns. In conjunction with the handheld thermal reader device, a bimodal-type LFIA that combines size-regulation- and shape-engineering-mediated colorimetric-photothermal dual-response assay (coined as the SSCPD assay) with a limit of detection of 0.012 ng mL-1 for ractopamine (RAC) monitoring is achieved by integrating Au-MnOx with the competitive-type immunoreaction. This work illustrates the effectiveness of this strategy for establishing high-performance sensing, and the SSCPD assay may be extended to a wide spectrum of future point-of-care (POC) diagnostic applications.
Collapse
Affiliation(s)
- Sijie Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Yangjun Liao
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Yinuo Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Rui Shu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Mingrui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Xing Luo
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Chenyang Sun
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Leina Dou
- National Key Laboratory of Veterinary Public Health Security, College of Veterinary Medicine, China Agricultural University, Beijing, 100193, China
| | - Linpin Luo
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Jing Sun
- Qinghai Key Laboratory of Qinghai-Tibet Plateau Biological Resources, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining, Qinghai, 810008, China
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| | - Lintao Zeng
- School of Light Industry and Food Engineering, Guangxi University, Nanning, 530004, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P.R. China
| |
Collapse
|
22
|
Panferov VG, Zherdev AV, Dzantiev BB. Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review. BIOSENSORS 2023; 13:866. [PMID: 37754100 PMCID: PMC10526817 DOI: 10.3390/bios13090866] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/15/2023] [Accepted: 08/23/2023] [Indexed: 09/28/2023]
Abstract
Lateral flow immunoassay (LFIA) has found a broad application for testing in point-of-care (POC) settings. LFIA is performed using test strips-fully integrated multimembrane assemblies containing all reagents for assay performance. Migration of liquid sample along the test strip initiates the formation of labeled immunocomplexes, which are detected visually or instrumentally. The tradeoff of LFIA's rapidity and user-friendliness is its relatively low sensitivity (high limit of detection), which restricts its applicability for detecting low-abundant targets. An increase in LFIA's sensitivity has attracted many efforts and is often considered one of the primary directions in developing immunochemical POC assays. Post-assay enhancements based on chemical reactions facilitate high sensitivity. In this critical review, we explain the performance of post-assay chemical enhancements, discuss their advantages, limitations, compared limit of detection (LOD) improvements, and required time for the enhancement procedures. We raise concerns about the performance of enhanced LFIA and discuss the bottlenecks in the existing experiments. Finally, we suggest the experimental workflow for step-by-step development and validation of enhanced LFIA. This review summarizes the state-of-art of LFIA with chemical enhancement, offers ways to overcome existing limitations, and discusses future outlooks for highly sensitive testing in POC conditions.
Collapse
Affiliation(s)
- Vasily G. Panferov
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
- Department of Chemistry, York University, Toronto, ON M3J 1P3, Canada
| | - Anatoly V. Zherdev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| | - Boris B. Dzantiev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| |
Collapse
|
23
|
Yang D, Hu J, Deng F. Paper based SERS aptasensor towards dual-modal detection of interferon gamma. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082589 DOI: 10.1109/embc40787.2023.10340492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Interferon gamma (IFN-γ), can serve as an active diagnostic biomarker of a broad spectrum of diseases such as auto inflammatory disease, viral and bacterial, parasites infections, and tumor control. The low physiological concentration of IFN-γ at pg‧mL-1 level for most diseases such as tuberculosis and lung cancer demand highly sensitive and selective detection methods. To achieve the goal, a novel paper-based SERS aptasensor towards rapid, dual-modal (visual and ultrasensitive) detection of IFN-γ is presented for the first time. A lateral flow platform with low-cost and user-friendly format in this study is adopted. The detection relies on the competition of the specific aptamer sequence of IFN-γ between its complementary DNA in the test line and IFN-γ in the sample solution. The presence of IFN-γ can be easily observed in the test line by naked eye and detected at pg‧mL-1 level by a portable Raman spectrometer. Linear detection range of 10-2000 pg‧mL-1 could be obtained with detection limit of 8.7 pg‧mL-1. In addition, as low as 10 pg/mL of IFN-γ in human serum could be detected, which is comparable with the results from ELISA.Clinical Relevance- This study establishes a simple, rapid, and low-cost assay for dual-modal detection of IFN-γ, which is in urgent demand in clinics especially vitally important in resource-limited areas.
Collapse
|
24
|
Younes N, Yassine HM, Kourentzi K, Tang P, Litvinov D, Willson RC, Abu-Raddad LJ, Nasrallah GK. A review of rapid food safety testing: using lateral flow assay platform to detect foodborne pathogens. Crit Rev Food Sci Nutr 2023; 64:9910-9932. [PMID: 37350754 DOI: 10.1080/10408398.2023.2217921] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
The detrimental impact of foodborne pathogens on human health makes food safety a major concern at all levels of production. Conventional methods to detect foodborne pathogens, such as live culture, high-performance liquid chromatography, and molecular techniques, are relatively tedious, time-consuming, laborious, and expensive, which hinders their use for on-site applications. Recurrent outbreaks of foodborne illness have heightened the demand for rapid and simple technologies for detection of foodborne pathogens. Recently, Lateral flow assays (LFA) have drawn attention because of their ability to detect pathogens rapidly, cheaply, and on-site. Here, we reviewed the latest developments in LFAs to detect various foodborne pathogens in food samples, giving special attention to how reporters and labels have improved LFA performance. We also discussed different approaches to improve LFA sensitivity and specificity. Most importantly, due to the lack of studies on LFAs for the detection of viral foodborne pathogens in food samples, we summarized our recent research on developing LFAs for the detection of viral foodborne pathogens. Finally, we highlighted the main challenges for further development of LFA platforms. In summary, with continuing improvements, LFAs may soon offer excellent performance at point-of-care that is competitive with laboratory techniques while retaining a rapid format.
Collapse
Affiliation(s)
- Nadin Younes
- Biomedical Research Center, Qatar University, Doha, Qatar
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar
| | - Hadi M Yassine
- Biomedical Research Center, Qatar University, Doha, Qatar
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar
| | - Katerina Kourentzi
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA
| | - Patrick Tang
- Department of Pathology, Sidra Medicine, Doha, Qatar
| | - Dmitri Litvinov
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA
- Center for Integrated Bio & Nano Systems, University of Houston, Houston, Texas, USA
| | - Richard C Willson
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA
- Department of Biology and Biochemistry, University of Houston, Houston, Texas, USA
| | - Laith J Abu-Raddad
- Infectious Disease Epidemiology Group, Weill Cornell Medicine-Qatar, Cornell University, Doha, Qatar
- World Health Organization Collaborating Centre for Disease Epidemiology Analytics on HIV/AIDS, Sexually Transmitted Infections, and Viral Hepatitis, Weill Cornell Medicine-Qatar, Cornell University, Doha, Qatar
- Department of Healthcare Policy and Research, Weill Cornell Medicine, Cornell University, New York, New York, USA
| | - Gheyath K Nasrallah
- Biomedical Research Center, Qatar University, Doha, Qatar
- Department of Biomedical Science, College of Health Sciences, QU Health, Qatar University, Doha, Qatar
| |
Collapse
|
25
|
Brosamer K, Kourentzi K, Willson RC, Vu BV. Glowstick-inspired smartphone-readable reporters for sensitive, multiplexed lateral flow immunoassays. COMMUNICATIONS ENGINEERING 2023; 2:31. [PMID: 38586601 PMCID: PMC10955955 DOI: 10.1038/s44172-023-00075-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 04/25/2023] [Indexed: 04/09/2024]
Abstract
The COVID-19 pandemic has increased demand for point-of-care (POC) screening tests such as lateral flow assays (LFAs) and highlighted the need for sensitive and cost-effective POC diagnostic platforms. Here, we demonstrate an LFA platform using standard fluorescent nanoparticle reporters in which optical excitation is replaced by chemical excitation using the peroxyoxalate-based chemistry of inexpensive, shelf-stable glowsticks. The one-step chemi-excitation of fluorescent particles produces visible light readable by an unmodified smartphone, enhancing sensitivity while preserving simplicity and cost-effectiveness. Our Glow LFA detected the common model analyte human chorionic gonadotropin with a limit of detection (LoD) of 39 pg/mL-over ten times more sensitive than standard gold nanoparticles using the same antibodies. We also demonstrate its application to the detection of SARS-CoV-2 nucleoprotein at 100 pg/mL in nasal swab extract. Multiple fluorescent dyes can be chemi-excited by a single reagent, allowing for color multiplexing on a single LFA strip with a smartphone camera. The detection of three analytes on a single LFA test line was demonstrated using red, green, and blue fluorescent reporter particles, making glow LFA a promising platform for multiplexed detection.
Collapse
Affiliation(s)
- Kristen Brosamer
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Katerina Kourentzi
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
| | - Richard C. Willson
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
- Escuela de Medicina y Ciencias de Salud, Tecnológico de Monterrey, Monterrey, Nuevo León 64710, Mexico
| | - Binh V. Vu
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
| |
Collapse
|
26
|
Ilyas A, Dyussupova A, Sultangaziyev A, Shevchenko Y, Filchakova O, Bukasov R. SERS immuno- and apta-assays in biosensing/bio-detection: Performance comparison, clinical applications, challenges. Talanta 2023; 265:124818. [PMID: 37453393 DOI: 10.1016/j.talanta.2023.124818] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 06/09/2023] [Accepted: 06/12/2023] [Indexed: 07/18/2023]
Abstract
Surface Enhanced Raman Spectroscopy is increasingly used as a sensitive bioanalytical tool for detection of variety of analytes ranging from viruses and bacteria to cancer biomarkers and toxins, etc. This comprehensive review describes principles of operation and compares the performance of immunoassays and aptamer assays with Surface Enhanced Raman scattering (SERS) detection to each other and to some other bioassay methods, including ELISA and fluorescence assays. Both immuno- and aptamer-based assays are categorized into assay on solid substrates, assays with magnetic nanoparticles and assays in laminar flow or/and strip assays. The best performing and recent examples of assays in each category are described in the text and illustrated in the figures. The average performance, particularly, limit of detection (LOD) for each of those methods reflected in 9 tables of the manuscript and average LODs are calculated and compared. We found out that, on average, there is some advantage in terms of LOD for SERS immunoassays (0.5 pM median LOD of 88 papers) vs SERS aptamer-based assays (1.7 pM median LOD of 51 papers). We also tabulated and analyzed the clinical performance of SERS immune and aptamer assays, where selectivity, specificity, and accuracy are reported, we summarized the best examples. We also reviewed challenges to SERS bioassay performance and real-life application, including non-specific protein binding, nanoparticle aggregation, limited nanotag stability, sometimes, relatively long time to results, etc. The proposed solutions to those challenges are also discussed in the review. Overall, this review may be interesting not only to bioanalytical chemist, but to medical and life science researchers who are interested in improvement of bioanalyte detection and diagnostics.
Collapse
Affiliation(s)
- Aisha Ilyas
- Department of Chemistry, SSH, Nazarbayev University, Astana, Kazakhstan
| | | | | | - Yegor Shevchenko
- Department of Chemistry, SSH, Nazarbayev University, Astana, Kazakhstan
| | - Olena Filchakova
- Department of Biology, SSH, Nazarbayev University, Astana, Kazakhstan
| | - Rostislav Bukasov
- Department of Chemistry, SSH, Nazarbayev University, Astana, Kazakhstan.
| |
Collapse
|
27
|
Zhang G, Hu H, Deng S, Xiao X, Xiong Y, Peng J, Lai W. An integrated colorimetric and photothermal lateral flow immunoassay based on bimetallic Ag-Au urchin-like hollow structures for the sensitive detection of E. coli O157:H7. Biosens Bioelectron 2023; 225:115090. [PMID: 36701950 DOI: 10.1016/j.bios.2023.115090] [Citation(s) in RCA: 34] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 01/16/2023] [Accepted: 01/19/2023] [Indexed: 01/22/2023]
Abstract
Lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as the signal reporter is widely used for the rapid detection of food-borne pathogens. However, it is difficult for LFIA to achieve sensitive detection due to the insufficient colorimetric signal brightness of AuNPs. Herein, we developed a bimetallic Ag-Au urchin-like hollow nanospheres (BUHNPs) based on the simple and rapid synthesis through co-reduction and galvanic replacement reactions. The BUHNPs exhibit superb colorimetric signal brightness, strong photothermal signals and high antibody coupling efficiency. The obtained colorimetric and photothermal LFIA (BUHNPs-CM-LFIA and BUHNPs-PT-LFIA) based on BUHNPs were used for the sensitive detection of a pathogenic bacterium (Escherichia coli O157:H7). The limit of detection values of the colorimetric and photothermal quantitative analysis were 2.48 × 103 and 5.50 × 102 CFU mL-1, which were approximately 4-fold and 18-fold lower than that of AuNPs-LFIA (9.92 × 103 CFU mL-1), respectively. This work suggests that a dual-readout LFIA with BUHNPs as a promising signal reporter can be used to improve the detection performance of LFIA and construct a more accurate and sensitive detection platform.
Collapse
Affiliation(s)
- Gan Zhang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Hong Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Shengliang Deng
- Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang, 330096, China.
| | - Xiaoyue Xiao
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Juan Peng
- School of Food Science, Nanchang University, Nanchang, 330047, China.
| | - Weihua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China.
| |
Collapse
|
28
|
Zhou M, Chen X, Shen XA, Lin X, Chen P, Qiao Z, Li X, Xiong Y, Huang X. Highly Sensitive Immunochromatographic Detection of Zearalenone Based on Ultrabright Red-Emitted Aggregation-Induced Luminescence Nanoprobes. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2023; 71:4408-4416. [PMID: 36866978 DOI: 10.1021/acs.jafc.3c00276] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Highly luminescent nanospheres have been demonstrated in enhancing the sensitivity of lateral flow immunoassay (LFIA) due to their loading numerous luminescent dyes. However, the photoluminescence intensities of existing luminescent nanospheres are limited due to the aggregation-caused quenching effect. Herein, highly luminescent aggregation-induced emission luminogens embedded nanospheres (AIENPs) with red emission were introduced as signal amplification probes of LFIA for quantitative detection of zearalenone (ZEN). Optical properties of red-emitted AIENPs were compared with time-resolved dye-embedded nanoparticles (TRNPs). Results showed that red-emitted AIENPs have stronger photoluminescence intensity on the nitrocellulose membrane and superior environmental tolerance. Additionally, we benchmarked the performance of AIENP-LFIA against TRNP-LFIA using the same set of antibodies, materials, and strip readers. Results showed that AIENP-LFIA exhibits good dynamic linearity with the ZEN concentration from 0.195 to 6.25 ng/mL, with half competitive inhibitory concentration (IC50) and detection of limit (LOD) at 0.78 and 0.11 ng/mL, respectively. The IC50 and LOD are 2.07- and 2.36-fold lower than those of TRNP-LFIA. Encouragingly, the precision, accuracy, specificity, practicality, and reliability of this AIENP-LFIA for ZEN quantitation were further characterized. The results verified that the AIENP-LFIA has good practicability for the rapid, sensitive, specific, and accurate quantitative detection of ZEN in corn samples.
Collapse
Affiliation(s)
- Mengjun Zhou
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
- Jiangxi General Institute of Testing and Certification Instituto for Food Control, Nanchang 330052, P. R. China
| | - Xirui Chen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
| | - Xuan-Ang Shen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
| | - Xiangkai Lin
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
| | - Ping Chen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
| | - Zhaohui Qiao
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, P. R. China
| | - Xiangmin Li
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
- Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang 330047, P. R. China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
- Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang 330047, P. R. China
| | - Xiaolin Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- School of Food Science and Technology, Nanchang University, Nanchang 330031, P. R. China
| |
Collapse
|
29
|
Bradley Z, Coleman PA, Courtney MA, Fishlock S, McGrath J, Uniacke-Lowe T, Bhalla N, McLaughlin JA, Hogan J, Hanrahan JP, Yan KT, McKee P. Effect of Selenium Nanoparticle Size on IL-6 Detection Sensitivity in a Lateral Flow Device. ACS OMEGA 2023; 8:8407-8414. [PMID: 36910974 PMCID: PMC9996617 DOI: 10.1021/acsomega.2c07297] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 02/17/2023] [Indexed: 06/18/2023]
Abstract
Sepsis is the body's response to an infection. Existing diagnostic testing equipment is not available in primary care settings and requires long waiting times. Lateral flow devices (LFDs) could be employed in point-of-care (POC) settings for sepsis detection; however, they currently lack the required sensitivity. Herein, LFDs are constructed using 150-310 nm sized selenium nanoparticles (SeNPs) and are compared to commercial 40 nm gold nanoparticles (AuNPs) for the detection of the sepsis biomarker interleukin-6 (IL-6). Both 310 and 150 nm SeNPs reported a lower limit of detection (LOD) than 40 nm AuNPs (0.1 ng/mL compared to 1 ng/mL), although at the cost of test line visual intensity. This is to our knowledge the first use of larger SeNPs (>100 nm) in LFDs and the first comparison of the effect of the size of SeNPs on assay sensitivity in this context. The results herein demonstrate that large SeNPs are viable alternatives to existing commercial labels, with the potential for higher sensitivity than standard 40 nm AuNPs.
Collapse
Affiliation(s)
- Zoe Bradley
- Biopanda
Reagents Ltd., Unit 14, Carrowreagh Business
Park, Carrowreagh Road, Belfast BT16 1QQ, United
Kingdom
- Nanotechnology
and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom
| | - Patrick A. Coleman
- Environmental
Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland
- Department
of Chemistry, College of SEFS, University
College Cork, Kane Building, Cork T12 YN60, Ireland
| | | | - Sam Fishlock
- Nanotechnology
and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom
| | - Joseph McGrath
- Environmental
Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland
| | - Therese Uniacke-Lowe
- Department
of Chemistry, School of Food and Nutritional Sciences, University College Cork, Level 2 Food Science Building, Cork T12 TP07, Ireland
| | - Nikhil Bhalla
- Nanotechnology
and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom
- Healthcare
Technology Hub, School of Engineering, University
of Ulster, Belfast BT15 1ED, United
Kingdom
| | - James A. McLaughlin
- Nanotechnology
and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom
| | - John Hogan
- Environmental
Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland
| | - John P. Hanrahan
- Environmental
Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland
| | - Ke-Ting Yan
- Biopanda
Reagents Ltd., Unit 14, Carrowreagh Business
Park, Carrowreagh Road, Belfast BT16 1QQ, United
Kingdom
| | - Philip McKee
- Biopanda
Reagents Ltd., Unit 14, Carrowreagh Business
Park, Carrowreagh Road, Belfast BT16 1QQ, United
Kingdom
| |
Collapse
|
30
|
Tay DMY, Kim S, Hao Y, Yee EH, Jia H, Vleck SM, Chilekwa M, Voldman J, Sikes HD. Accelerating the optimization of vertical flow assay performance guided by a rational systematic model-based approach. Biosens Bioelectron 2023; 222:114977. [PMID: 36516633 DOI: 10.1016/j.bios.2022.114977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 11/29/2022] [Indexed: 12/12/2022]
Abstract
Rapid diagnostic tests (RDTs) have shown to be instrumental in healthcare and disease control. However, they have been plagued by many inefficiencies in the laborious empirical development and optimization process for the attainment of clinically relevant sensitivity. While various studies have sought to model paper-based RDTs, most have relied on continuum-based models that are not necessarily applicable to all operation regimes, and have solely focused on predicting the specific interactions between the antigen and binders. It is also unclear how the model predictions may be utilized for optimizing assay performance. Here, we propose a streamlined and simplified model-based framework, only relying on calibration with a minimal experimental dataset, for the acceleration of assay optimization. We show that our models are capable of recapitulating experimental data across different formats and antigen-binder-matrix combinations. By predicting signals due to both specific and background interactions, our facile approach enables the estimation of several pertinent assay performance metrics such as limit-of-detection, sensitivity, signal-to-noise ratio and difference. We believe that our proposed workflow would be a valuable addition to the toolset of any assay developer, regardless of the amount of resources they have in their arsenal, and aid assay optimization at any stage in their assay development process.
Collapse
Affiliation(s)
- Dousabel M Y Tay
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Microsystems Technology Laboratory, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Seunghyeon Kim
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Yining Hao
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Emma H Yee
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Huan Jia
- Antimicrobial Resistance Integrated Research Group, Singapore-MIT Alliance for Research and Technology, 1 CREATE Way, Singapore, 138602, Singapore
| | - Sydney M Vleck
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Makaya Chilekwa
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Joel Voldman
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Microsystems Technology Laboratory, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Hadley D Sikes
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA; Antimicrobial Resistance Integrated Research Group, Singapore-MIT Alliance for Research and Technology, 1 CREATE Way, Singapore, 138602, Singapore.
| |
Collapse
|
31
|
Hao W, Huang Y, Wang L, Liang J, Yang S, Su L, Zhang X. Smartphone-Based Photothermal Lateral Flow Immunoassay Using Rhenium Diselenide Nanosheet. ACS APPLIED MATERIALS & INTERFACES 2023; 15:9665-9674. [PMID: 36780303 PMCID: PMC9940616 DOI: 10.1021/acsami.2c22616] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 01/31/2023] [Indexed: 06/18/2023]
Abstract
Developing a rapid antibody-based detection method is of great importance for preventing and controlling the spread of coronavirus disease 2019 (COVID-19). Among the antibody-based methods for point-of-care (POC) detection, lateral flow immunoassay (LFIA) is the most widely used. However, LFIA still has the disadvantage of low sensitivity. In this work, an ReSe2 nanosheet with a thickness of 10-20 nm was prepared by liquid exfoliation and applied as the label in a photothermal LFIA due to its high photothermal conversion efficiency and high photothermal stability. An integrated detection device was introduced for rapid, on-site, and highly sensitive assay of the human antisevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Spike (S) protein IgG antibodies. The device mainly included a rhenium diselenide (ReSe2) nanosheet-based photothermal LFIA, a portable laser, and a smartphone with a portable thermal imager, which was used to record and analyze the thermal signal of the LFIA test zone. The human anti-SARS-COV-2 S protein IgG antibodies in buffer solution can be detected in a portable box within 10 min, with a thermal signal detection limit of 0.86 ng mL-1, which was 108-fold lower than that of the colorimetric signal. The integrated device can detect values as low as 2.76 ng mL-1 of the human anti-SARS-COV-2 S protein IgG antibodies in 50% serum. The integrated device showed great potential for rapid and home self-testing diagnosis of COVID-19.
Collapse
Affiliation(s)
- Wenbin Hao
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Yan Huang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Lei Wang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Jing Liang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - ShuangShuang Yang
- Beijing
Key Laboratory for Bioengineering and Sensing Technology, School of
Chemistry and Biological Engineering; Beijing Advanced Innovation
Center for Materials Genome Engineering, School of Materials Science
and Engineering, University of Science &
Technology Beijing, Beijing 100083, P. R. China
| | - Lei Su
- School
of Biomedical Engineering, Shenzhen University
Health Science Center, Shenzhen 518060, China
| | - Xueji Zhang
- School
of Biomedical Engineering, Shenzhen University
Health Science Center, Shenzhen 518060, China
| |
Collapse
|
32
|
Yang D, Wang L, Jia T, Lian T, Yang K, Li X, Wang X, Xue C. Au/Fe 3O 4-based nanozymes with peroxidase-like activity integrated in immunochromatographic strips for highly-sensitive biomarker detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:663-674. [PMID: 36655548 DOI: 10.1039/d2ay01815b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Because of their simplicity, rapidity, and cost-effectiveness, immunochromatographic strips (ICTs) have been widely used as an effective tool in various fields. However, typical strips for the preliminary screening suffer from limited detection sensitivity, particularly in biomarker detection with trace concentration. Herein, to tackle this challenge, we integrated homemade gold-decorated Fe3O4 nanoparticles (Au/Fe3O4 NPs) with flexible strips, exploring the excellent peroxidase-like activity of this labeled material, and then enhancing the detection sensitivity via signal amplification. The limit of detection (LOD) of the strips is as low as 0.05 mIU mL-1 when human chorionic gonadotropin (hCG) is as a biomarker model, which is 500 times lower than that of the traditional color-based strip. Overall, our results demonstrated the potential for Au/Fe3O4 NP based-ICTs for the rapid detection of the biomarker in an instrument-free and point-of-care testing format.
Collapse
Affiliation(s)
- Dong Yang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Lixia Wang
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Tongtong Jia
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Ting Lian
- School of Clinical Medicine, Xi'an Medical University, Xi'an 710021, China
| | - Kadi Yang
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Xuhua Li
- College of Chemistry and Chemical Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- Xi'an Key Laboratory of Advanced Performance Materials and Polymers, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Xue Wang
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
- Key Laboratory of Chemical Additives for China National Light Industry, Xi'an 710021, China
| | - Chaohua Xue
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science & Technology, Xi'an 710021, China.
| |
Collapse
|
33
|
Shu R, Liang Y, Liu S, Dou L, Bu T, Wang S, Lan X, Zhang D, Sun J, Zhu M, Wang J. "From food waste to food supervision"-Cuttlefish Ink Natural Nanoparticles-Driven Dual-mode Lateral Flow Immunoassay for Advancing Point-of-Care Tests. Biosens Bioelectron 2023; 219:114807. [PMID: 36327557 DOI: 10.1016/j.bios.2022.114807] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 10/10/2022] [Indexed: 11/19/2022]
Abstract
Apart from the obvious benefit of "trash-to-treasure", the acquisition of natural nanomaterials from cheap and renewable waste has been intensively researched because of various bioactivities and physical-chemical features. Herein, for the first time, we employed natural cuttlefish ink nanoparticles (CINPs) as a multifunctional label and designed colorimetric-photothermal dual-mode lateral flow immunoassays (CINPs-mediated CPLFIA) for sensitive detection of clenbuterol (CL). The accessibility and renewability of CINPs overcome barriers that artificial nanomaterials face, such as complex manufacturing and relatively high costs. Additionally, inspired by the mussel adhesion, the bio-affinity of CINPs, such as antibody coupling and preservation, was investigated and showed to be considerably superior to Au NPs, leading to significantly increased immunosensor sensitivity. Meanwhile, CINPs exhibit excellent photothermal conversion efficiency for dual-signal production, avoiding the effect of environmental elements (particularly light) for colorimetric mode. Besides, the biosensor was integrated with a smartphone and a thermal imager for portable sensing. After optimization, the detection limit of CINPs-mediated CPLFIA was 0.179 ng mL-1 (colorimetric mode) and 0.076 ng mL-1 (photothermal mode), which were significantly lower than traditional gold nanoparticles-based LFIA (0.786 ng mL-1). This research attempted to explain the rise in sensitivity. From food waste to food supervision, this research explores the hidden value of natural resources.
Collapse
Affiliation(s)
- Rui Shu
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Yanmin Liang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Sijie Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Leina Dou
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, And Beijing Laboratory for Food Quality and Safety, Beijing, 100193, China
| | - Tong Bu
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Shaochi Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Xi Lan
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Jing Sun
- Qinghai Provincial Key Laboratory of Qinghai-Tibet Plateau Biological Resources, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Qinghai, 810008, China
| | - Mingqiang Zhu
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling, 712100, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China.
| |
Collapse
|
34
|
Fang B, Xiong Q, Duan H, Xiong Y, Lai W. Tailored quantum dots for enhancing sensing performance of lateral flow immunoassay. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
35
|
Dong S, Guan L, Zhao Y, Wang Y, Liu P, Li P, Han C, Liu B, Zhang C. A dual-signal immunochromatographic assay using quantum dots and polydopamine coated gold nanoparticles for detection of sodium pentachlorophenate in animal-derived food. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
36
|
Zhang JJ, Nie C, Fu WL, Cheng FL, Chen P, Gao ZF, Wu Y, Shen Y. Photoresponsive DNA-Modified Magnetic Bead-Assisted Rolling Circle Amplification-Driven Visual Photothermal Sensing of Escherichia coli. Anal Chem 2022; 94:16796-16802. [DOI: 10.1021/acs.analchem.2c03714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Affiliation(s)
- Jing Jing Zhang
- Advanced Materials Institute, Qilu University of Technology, Shandong Academy of Sciences, Jinan250014, China
| | - Chao Nie
- School of Food and Biological Engineering, Engineering Research Center of Bio-Process, Ministry of Education, Hefei University of Technology, Hefei230009, China
| | - Wen Long Fu
- Advanced Materials Institute, Qilu University of Technology, Shandong Academy of Sciences, Jinan250014, China
| | - Feng Li Cheng
- Advanced Materials Institute, Qilu University of Technology, Shandong Academy of Sciences, Jinan250014, China
| | - Pu Chen
- Advanced Materials Institute, Qilu University of Technology, Shandong Academy of Sciences, Jinan250014, China
| | - Zhong Feng Gao
- Advanced Materials Institute, Qilu University of Technology, Shandong Academy of Sciences, Jinan250014, China
- Key Laboratory of Interfacial Reaction and Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan250022, China
| | - Yongning Wu
- Research Unit of Food Safety, Chinese Academy of Medical Sciences (No. 2019RU014); NHC Key Lab of Food Safety Risk Assessment, China National Center for Food Safety Risk Assessment (CFSA), Beijing100022, China
| | - Yizhong Shen
- School of Food and Biological Engineering, Engineering Research Center of Bio-Process, Ministry of Education, Hefei University of Technology, Hefei230009, China
| |
Collapse
|
37
|
Luciano K, Wang X, Liu Y, Eyler G, Qin Z, Xia X. Noble Metal Nanoparticles for Point-of-Care Testing: Recent Advancements and Social Impacts. Bioengineering (Basel) 2022; 9:666. [PMID: 36354576 PMCID: PMC9687823 DOI: 10.3390/bioengineering9110666] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 10/28/2022] [Accepted: 11/06/2022] [Indexed: 09/01/2023] Open
Abstract
Point-of-care (POC) tests for the diagnosis of diseases are critical to the improvement of the standard of living, especially for resource-limited areas or countries. In recent years, nanobiosensors based on noble metal nanoparticles (NM NPs) have emerged as a class of effective and versatile POC testing technology. The unique features of NM NPs ensure great performance of associated POC nanobiosensors. In particular, NM NPs offer various signal transduction principles, such as plasmonics, catalysis, photothermal effect, and so on. Significantly, the detectable signal from NM NPs can be tuned and optimized by controlling the physicochemical parameters (e.g., size, shape, and elemental composition) of NPs. In this article, we introduce the inherent merits of NM NPs that make them attractive for POC testing, discuss recent advancement of NM NPs-based POC tests, highlight their social impacts, and provide perspectives on challenges and opportunities in the field. We hope the review and insights provided in this article can inspire new fundamental and applied research in this emerging field.
Collapse
Affiliation(s)
- Keven Luciano
- Department of Chemistry, University of Central Florida, Orlando, FL 32816, USA
| | - Xiaochuan Wang
- School of Social Work, College of Health Professions and Sciences, University of Central Florida, Orlando, FL 32816, USA
| | - Yaning Liu
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA
| | - Gabriella Eyler
- School of Social Work, College of Health Professions and Sciences, University of Central Florida, Orlando, FL 32816, USA
| | - Zhenpeng Qin
- Department of Mechanical Engineering, University of Texas at Dallas, Richardson, TX 75080, USA
- Department of Bioengineering, Center for Advanced Pain Studies, University of Texas at Dallas, Richardson, TX 75080, USA
- Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Xiaohu Xia
- Department of Chemistry, University of Central Florida, Orlando, FL 32816, USA
| |
Collapse
|
38
|
Jin B, Du Z, Zhang C, Yu Z, Wang X, Hu J, Li Z. Eu-Chelate Polystyrene Microsphere-Based Lateral Flow Immunoassay Platform for hs-CRP Detection. BIOSENSORS 2022; 12:977. [PMID: 36354486 PMCID: PMC9688000 DOI: 10.3390/bios12110977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/25/2022] [Accepted: 11/01/2022] [Indexed: 06/16/2023]
Abstract
Inflammation caused by viral or bacterial infection is a major threat to human health globally. Blood C-reactive protein (CRP) has been proven to be a sensitive indicator for the occurrence and development of inflammation. Furthermore, a tiny change of blood CRP concentration may portend chronic diseases; therefore, high-sensitivity CRP (hs-CRP) detection in a quantitative, rapid, user-friendly, and low-cost manner is highly demanded. In this paper, we developed a europium-chelate polystyrene microsphere (EuPSM)-based lateral flow immunoassay (LFIA) integrating with a benchtop fluorescence analyzer for hs-CRP detection. The optimization of the EuPSM-based LFIA was implemented through adjusting the antibody density on EuPSM from 100% to 60% of the saturated density. Finally, the limit of detection of 0.76 pg/mL and detection range of 0.025-250 ng/mL were obtained. Moreover, the clinical application capability of the proposed platform was validated through detecting CRP in clinical serum samples, showing high consistency with the results obtained from the clinical standard method. Hence, the proposed EuPSM-based LFIA has been verified to be well suitable for hs-CRP detection, while also showing great applicability for sensitively and rapidly detecting other biomarkers.
Collapse
Affiliation(s)
- Birui Jin
- School of Materials and Chemical Engineering, Xi’an Technological University, Xi’an 710021, China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, China
| | - Zhiguo Du
- School of Materials and Chemical Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Chuyao Zhang
- School of Materials and Chemical Engineering, Xi’an Technological University, Xi’an 710021, China
| | - Zhao Yu
- Xi’an Thermal Power Research Institute Co., Ltd., Xi’an 710054, China
| | - Xuemin Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
- Department of Radiotherapy Hospital Unit Radiation Therapy, Shaanxi Provincial Tumor Hospital, Xi’an 710061, China
| | - Jie Hu
- Suzhou DiYinAn Biotech Co., Ltd., Suzhou Innovation Center for Life Science and Technology, Suzhou 215129, China
| | - Zedong Li
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
| |
Collapse
|
39
|
Liu S, Luo X, Shu R, Liao Y, Dou L, Bu T, Wang S, Li Y, Sun J, Zhang D, Zhu M, Wang J. Engineered Core-Shell Multifunctional Nano-Tracer in Raman-Silent Region with Highly Retained Affinity to Enhance Lateral Flow Immunoassays. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2204859. [PMID: 36161770 DOI: 10.1002/smll.202204859] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/08/2022] [Indexed: 06/16/2023]
Abstract
Stimulated surface-enhanced Raman scattering (SERS) in combination with engineered nano-tracer offers extraordinary potential in lateral flow immunoassays (LFIAs). Nonetheless, the investigation execution of SERS-LFIA is often compromised by the intricacy and overlap of the Raman fingerprint spectrum as well as the affinity-interference of nano-tracer to antibody. To circumvent these critical issues, an engineered core-shell multifunctional nano-tracer (named APNPs) with precise control of the size of nano-core (AuNPs) and coating of the nano-shell (Prussian blue nanomaterials) is prepared for SERS-LFIA via a modified enlarging particle size and coating modification strategy. Importantly, this nano-tracer exhibits enhanced coupling efficiency, highly retained affinity, reinforced colloid stability, and unique SERS signal (2156 cm-1 ) in the silent region (1800-2800 cm-1 ) with high signal-to-background ratio simultaneously, all of which are beneficial to the enhancement of the analysis performance. With a proof-of-concept demonstration for detection of ractopamine (RAC), a dual-pattern LFIA that synergizes both the enlarged particle size and coating modification supported colorimetric/biological silence Raman dual-response (coined as the ECCRD assay) is demonstrated by integrating APNPs with the competitive-type immunoreaction. This research may contribute to the rational design of multifunctional nano-tracer, and the ECCRD assay can be expanded for a wide spectrum of applications in environmental monitoring and biomedical diagnosis.
Collapse
Affiliation(s)
- Sijie Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Xing Luo
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Rui Shu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Yangjun Liao
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Leina Dou
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, Beijing, 100193, P. R. China
| | - Tong Bu
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Shaochi Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Yuechun Li
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Jing Sun
- Qinghai Key Laboratory of Qinghai-Tibet Plateau Biological Resources, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining, Qinghai, 810008, P. R. China
| | - Daohong Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| | - Mingqiang Zhu
- College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling, 712100, P. R. China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China
| |
Collapse
|
40
|
Wang P, Xu X, Liu L, Song S, Kuang H, Xu C, Wu X. A colloidal gold immunochromatography for the detection of flumioxazin residues in fruits. J Food Sci 2022; 87:4538-4547. [DOI: 10.1111/1750-3841.16288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 06/26/2022] [Accepted: 07/22/2022] [Indexed: 11/30/2022]
Affiliation(s)
- Peng Wang
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| | - Xinxin Xu
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| | - Liqiang Liu
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| | - Shanshan Song
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| | - Xiaoling Wu
- State Key Laboratory of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- International Joint Research Laboratory for Biointerface and Biodetection and School of Food Science and Technology Jiangnan University, Wuxi, Jiangsu 214122 People's Republic of China
- Collaborative Innovation center of Food Safety and Quality Control in Jiangsu Province Jiangnan University Wuxi Jiangsu People's Republic of China
| |
Collapse
|
41
|
Yang H, He Q, Lin M, Ji L, Zhang L, Xiao H, Li S, Li Q, Cui X, Zhao S. Multifunctional Au@Pt@Ag NPs with color-photothermal-Raman properties for multimodal lateral flow immunoassay. JOURNAL OF HAZARDOUS MATERIALS 2022; 435:129082. [PMID: 35650752 DOI: 10.1016/j.jhazmat.2022.129082] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/20/2022] [Accepted: 05/03/2022] [Indexed: 06/15/2023]
Abstract
Multimodal lateral flow immunoassay (LFIA) has displayed its potential to improve practicability and elasticity of point-of-care testing. Herein, multifunctional core-shell-shell Au@Pt@Ag NPs loaded with dual-layer Raman reporter molecules of 5,5'-dithiobis-(2-nitrobenzoic acid) (DTNB) with a characteristic combination of color-photothermal-Raman performance were constructed for colorimetric LFIA (CM-LFIA), photothermal LFIA (PT-LFIA) and surface-enhanced Raman scattering-based LFIA (SERS-LFIA), respectively. The highly specific nanoprobes, being obtained through the combination of the resulted dual-layer DTNB modified Au@Pt@Ag NPs with the antibody, were triumphantly utilized in exploring multimodal LFIA with one visual qualitative and two optional quantitative modes with excellent sensing sensitivity. Under optimal conditions, the limit of detection (LOD) for the model hazardous analyte dehydroepiandrosterone (DHEA) were 1.0 ng mL-1 for CM-LFIA, 0.42 ng mL-1 for PT-LFIA, and 0.013 ng mL-1 for SERS-LFIA, three of which were over 100-fold, 200-fold and 7 000-fold more sensitive than conventional visual AuNPs-based LFIA, respectively. In addition, the quantitative PT-LFIA and SERS-LFIA sensors worked well in spiked real samples with acceptable recoveries of 96.2 - 106.7% and 98.2 - 105.2%, respectively. This assay demonstrated that the developed multimodal LFIA had a great potential to be a powerful tool for accurate tracing hazardous analytes in complex samples.
Collapse
Affiliation(s)
- Huiyi Yang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Qiyi He
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Mingxia Lin
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Li Ji
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Leheng Zhang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Huanxin Xiao
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Shijia Li
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Qinglan Li
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Xiping Cui
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Suqing Zhao
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| |
Collapse
|
42
|
Mokhtar HE, Xu A, Xu Y, Fadlalla MH, Wang S. Preparation of Monoclonal Antibody against Deoxynivalenol and Development of Immunoassays. Toxins (Basel) 2022; 14:toxins14080533. [PMID: 36006195 PMCID: PMC9415657 DOI: 10.3390/toxins14080533] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/27/2022] [Accepted: 07/28/2022] [Indexed: 11/16/2022] Open
Abstract
Fusarium toxins are the largest group of mycotoxins, which contain more than 140 known secondary metabolites of fungi. Deoxynivalenol (DON) is one of the most important compounds of this class due to its high toxicity and its potential to harm mankind and animals and a widespread contaminant of agricultural commodities, such as wheat, corn, barley, oats, bread, and biscuits. Herein, a hybridoma cell 8G2 secreting mAb against DON was produced by fusing the splenocytes with a tumor cell line Sp2/0. The obtained mAb had a high affinity (2.39 × 109 L/mol) to DON. An indirect competitive Enzyme-Linked Immunosorbent Assay (ic-ELISA) showed that the linear range for DON detection was 3.125–25 μg/mL, and the minimum inhibitory concentration (IC50) was 18.125 μg/mL with a limit of detection (LOD) of 7.875 μg/mL. A colloidal gold nanoparticle (AuNP) with 20 nm in diameter was synthesized for on-site detection of DON within 10 min with vLOD of 20 μg/mL. To improve the limit of detection, the gold nanoflower (AuNF) with a larger size (75 nm) was used to develop the AuNF-based strip with vLOD of 6.67 μg/mL. Compared to the vLOD of a convectional AuNP-based strip, the AuNF-based strip was three times lower. Herein, three immunoassay methods (ic-ELISA and AuNP/AuNF-based strips) were successfully developed, and these methods could be applied for the DON detection in agricultural products.
Collapse
|
43
|
Khoris IM, Kenta T, Ganganboina AB, Park EY. Pt-embodiment ZIF-67-derived nanocage as enhanced immunoassay for infectious virus detection. Biosens Bioelectron 2022; 215:114602. [PMID: 35940003 DOI: 10.1016/j.bios.2022.114602] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 07/21/2022] [Accepted: 07/25/2022] [Indexed: 11/19/2022]
Abstract
A facile and general strategy has been employed to develop highly-active nanozyme for immunoassay purposes. The hollow nanostructure of the Co3O4 nanocages (NCs) was anchoring the platinum nanoparticles (PtNPs) enclosed by the exposed oxides framework nd formed PtNPs@Co3O4 NCs. The embodiment of PtNPs was considered an ideal hybrid nanozyme that efficiently catalyzed the oxidation of the substrate molecules with enhanced activity. The PtNPs@Co3O4 NCs were revisited and repurposed on showing its nanozyme's activity with optimization done for the immunoassay platform. The embodiment of 32.44% Pt in the hollow nanostructures demonstrated the highest signal-to-noise responses in the immunoassay. In addition, the stepwise analysis highlighted the enhancement factor of the nanocages' catalytic mechanism. Based on their catalytic activity, these nanocages have been demonstrated to enable sub-femtogram level biosensing of norovirus-like particles (NoV-LPs) with highly selective signals in the capture-detect immunoassay format. The detection limit of the prepared immunoassay achieved 33.52 viral NoV copies/mL of the detection limit, which is 321-folds lower magnitude of the commercial ELISA. This nanocage's enhanced synergic catalytic properties could have great potential applications, including catalysis, biological labeling, and bioassays.
Collapse
Affiliation(s)
- Indra Memdi Khoris
- Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
| | - Tsuruga Kenta
- Department of Applied Biological Science, Graduate School of Integrated Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
| | - Akhilesh Babu Ganganboina
- International Center for Young Scientists ICYS-NAMIKI, National Institute for Materials Science, 1-2-1 Sengen Tsukuba City, Ibaraki, 305-0047, Japan
| | - Enoch Y Park
- Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan; Department of Applied Biological Science, Graduate School of Integrated Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan; Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan.
| |
Collapse
|
44
|
Liu Y, Zhan L, Kangas J, Wang Y, Bischof J. Fast and ultrafast thermal contrast amplification of gold nanoparticle-based immunoassays. Sci Rep 2022; 12:12729. [PMID: 35882876 PMCID: PMC9321340 DOI: 10.1038/s41598-022-14841-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 06/13/2022] [Indexed: 11/27/2022] Open
Abstract
For highly sensitive point-of-care (POC) diagnostics, we explored the limit of thermal contrast amplification (TCA) reading of gold nanoparticles (GNPs/mm2) at test regions in immunoassays. More specifically, we built and compared fast (minute scale) and ultrafast (seconds scale) TCA setups using continuous-wave (CW) and ms pulsed lasers, respectively. TCA improved the limit of detection (LoD) for silica-core gold nanoshells (GNSs) preloaded in nitrocellulose (NC) membrane as model lateral flow immunoassays (LFAs) by 10- to 20-fold over visual reading. While the ultrafast TCA led to higher thermal signals, this came with a twofold loss in LoD vs. fast TCA primarily due to noise within the infrared sensor and a necessity to limit power to avoid burning. To allow higher laser power, and therefore amplification fold, we also explored transparent glass coverslip substrate as a model microfluidic immunoassay (MIA). We found the ultrafast TCA reading of GNS-coated coverslips achieved a maximal signal amplification (57-fold) over visual reading of model LFAs. Therefore, ultrafast TCA-MIA is promising for ultrasensitive and ultrafast diagnostics. Further advantages of using TCA in MIA vs. LFA could include lower sample volume, multiplexed tests, higher throughput, and fast reading. In summary, TCA technology is able to enhance the sensitivity and speed of reading GNPs (GNPs/mm2) within both LFAs and MIAs.
Collapse
Affiliation(s)
- Yilin Liu
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Li Zhan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Joseph Kangas
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Yiru Wang
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - John Bischof
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA. .,Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA.
| |
Collapse
|
45
|
Development of a Rapid Gold Nanoparticle-Based Lateral Flow Immunoassay for the Detection of Dengue Virus. BIOSENSORS 2022; 12:bios12070495. [PMID: 35884298 PMCID: PMC9313084 DOI: 10.3390/bios12070495] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 06/29/2022] [Accepted: 07/04/2022] [Indexed: 11/16/2022]
Abstract
Flavivirus detection in humans and mosquito reservoirs has been an important issue since it can cause a variety of illnesses and could represent a health problem in geographical zones where the vector is endemic. In this work, we designed and characterized a biosensor based on gold nanoparticles (AuNPs) and antibody 4G2 for the detection of dengue virus (DENV) in vitro, obtaining different conjugates (with different antibody concentrations). The AuNP–4G2 conjugates at concentrations of 1, 3, and 6 µg/mL presented an increase in the average hydrodynamic diameter compared to the naked AuNPs. Also, as part of the characterization, differences in the UV-Vis absorbance spectrum and electrophoretic migration were observed between the conjugated AuNPs (with BSA or antibody) and naked AuNPs. Additionally, we used this biosensor (AuNP–4G2 conjugate with 3 µg/mL antibody) in the assembly of a competitive lateral flow assay (LFA) for the development of an alternative test to detect the flavivirus envelope protein in isolated DENV samples as a future tool for dengue detection (and other flaviviruses) in the mosquito vector (Aedesaegypti) for the identification of epidemic risk regions. Functionality tests were performed using Dengue virus 2 isolated solution (TCID50/mL = 4.58 × 103) as a positive sample and PBS buffer as a negative control. The results showed that it is possible to detect Dengue virus in vitro with this gold nanoparticle-based lateral flow assay with an estimated detection limit of 5.12 × 102 PFU. We suggest that this biosensor could be used as an additional detection tool by coupling it to different point-of-care tests (POCT) for the easy detection of other flaviviruses.
Collapse
|
46
|
Miller BS, Thomas MR, Banner M, Kim J, Chen Y, Wei Q, Tseng DK, Göröcs ZS, Ozcan A, Stevens MM, McKendry RA. Sub-picomolar lateral flow antigen detection with two-wavelength imaging of composite nanoparticles. Biosens Bioelectron 2022; 207:114133. [DOI: 10.1016/j.bios.2022.114133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 02/02/2022] [Accepted: 02/22/2022] [Indexed: 01/20/2023]
|
47
|
Hui YY, Tang Y, Azuma T, Lin H, Liao F, Chen Q, Kuo J, Wang Y, Chang H. Design and implementation of a low‐cost portable reader for thermometric lateral flow immunoassay. J CHIN CHEM SOC-TAIP 2022. [DOI: 10.1002/jccs.202200124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Yuen Yung Hui
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Yi‐Xiu Tang
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Terumitsu Azuma
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Physics National Taiwan University Taipei Taiwan
| | - Hsin‐Hung Lin
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Fang‐Zhen Liao
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Qing‐Ying Chen
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Chemical Engineering National Taiwan University of Science and Technology Taipei Taiwan
| | - Jen‐Hwa Kuo
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Institute of Brain Sciences National Yang Ming Chiao Tung University Taipei Taiwan
| | - Yuh‐Lin Wang
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Physics National Taiwan University Taipei Taiwan
| | - Huan‐Cheng Chang
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Chemical Engineering National Taiwan University of Science and Technology Taipei Taiwan
- Department of Chemistry National Taiwan Normal University Taipei Taiwan
| |
Collapse
|
48
|
Ardekani LS, Thulstrup PW. Gold Nanoparticle-Mediated Lateral Flow Assays for Detection of Host Antibodies and COVID-19 Proteins. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:1456. [PMID: 35564165 PMCID: PMC9102158 DOI: 10.3390/nano12091456] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 04/17/2022] [Accepted: 04/19/2022] [Indexed: 01/15/2023]
Abstract
Coronaviruses, that are now well-known to the public, include a family of viruses that can cause severe acute respiratory syndrome (SARS) and other respiratory diseases, such as Middle East respiratory syndrome (MERS). Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the seventh member of this coronavirus family, was detected in 2019 and can cause a number of respiratory symptoms, from dry cough and fever to fatal viral pneumonia. Various diagnostic assays ranging from real-time polymerase chain reaction (RT-PCR) to point-of-care medical diagnostic systems have been developed for detection of viral components or antibodies targeting the virus. Point-of-care assays allow rapid diagnostic assessment of infectious patients. Such assays are ideally simple, low-cost, portable tests with the possibility for on-site field detection that do not require skilled staff, sophisticated equipment, or sample pretreatment, as compared to RT-PCR. Since early 2021 when new SARS-CoV-2 variants of concern increased, rapid tests became more crucial in the disease management cycle. Among rapid tests, gold nanoparticle (GNP)-based lateral flow assays (LFAs) have high capacity for performing at the bedside, paving the way to easy access to diagnosis results. In this review, GNP-based LFAs used for either COVID-19 proteins or human response antibodies are summarized and recommendations for their improvement have been suggested.
Collapse
Affiliation(s)
- Leila Safaee Ardekani
- Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Tehran P.O. Box 14115-111, Iran
| | - Peter Waaben Thulstrup
- Department of Chemistry, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen, Denmark
| |
Collapse
|
49
|
Bu T, Bai F, Zhao S, Sun X, Jia P, He K, Wang Y, Li Q, Wang L. Dual-Modal Immunochromatographic Test for Sensitive Detection of Zearalenone in Food Samples Based On Biosynthetic Staphylococcus aureus-Mediated Polymer Dot Nanocomposites. Anal Chem 2022; 94:5546-5554. [PMID: 35348339 DOI: 10.1021/acs.analchem.1c04721] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The rapid detection of toxins is of great significance to food security and human health. In this work, a dual-modality immunochromatographic test (DICT) mediated by Staphylococcus aureus (SA)-biosynthesized polymer dots (SABPDs) was constructed for sensitive monitoring of zearalenone (ZEN) in agro products. The SABPDs as potent microorganism nanoscaffolds with excellent solubility, brightness, and stability were ingeniously fabricated employing hydroquinone and SA as precursors in the Schiff base reaction and a self-assembly technique. Thanks to the fact that they not only preserved an intact microsphere for loading Fc regions of monoclonal antibodies (mAbs) and the affinity of their labeled mAbs to antigen but also generated superb colorimetric-fluorescent dual signals, the versatile SABPDs manifested unique possibilities as the new carriers for dual-readout ICT with remarkable enhancement in sensitivity in ZEN screening (limit of detection = 0.036 ng/mL, which was 31-fold lower than that of traditional gold nanoparticle-based ICT). Ultimately, the proposed immunosensor performed well in millet and corn samples with satisfactory recoveries, demonstrating its potential for point-of-care testing. This work offers a bio-friendly strategy for biosynthesizing cell-based PD vehicles with bimodal signals for food safety analysis.
Collapse
Affiliation(s)
- Tong Bu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Feier Bai
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Shuang Zhao
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Xinyu Sun
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Pei Jia
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Kunyi He
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Ying Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| | - Qing Li
- College of Food Science and Engineering, The Test Center, Northwest A&F University, Yangling 712100, Shaanxi, China
| | - Li Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.,Shenzhen Research Institute Northwest A&F University, Shenzhen 518000, Guangdong, China
| |
Collapse
|
50
|
Azuma T, Hui YY, Chen OY, Wang YL, Chang HC. Thermometric lateral flow immunoassay with colored latex beads as reporters for COVID-19 testing. Sci Rep 2022; 12:3905. [PMID: 35273286 PMCID: PMC8913781 DOI: 10.1038/s41598-022-07963-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Accepted: 02/28/2022] [Indexed: 12/16/2022] Open
Abstract
Temperature sensing is a promising method of enhancing the detection sensitivity of lateral flow immunoassay (LFIA) for point-of-care testing. A temperature increase of more than 100 °C can be readily achieved by photoexcitation of reporters like gold nanoparticles (GNPs) or colored latex beads (CLBs) on LFIA strips with a laser power below 100 mW. Despite its promise, processes involved in the photothermal detection have not yet been well-characterized. Here, we provide a fundamental understanding of this thermometric assay using non-fluorescent CLBs as the reporters deposited on nitrocellulose membrane. From a measurement for the dependence of temperature rises on the number density of membrane-bound CLBs, we found a 1.3-fold (and 3.2-fold) enhancement of the light absorption by red (and black) latex beads at 520 nm. The enhancement was attributed to the multiple scattering of light in this highly porous medium, a mechanism that could make a significant impact on the sensitivity improvement of LFIA. The limit of detection was measured to be 1 × 105 particles/mm2. In line with previous studies using GNPs as the reporters, the CLB-based thermometric assay provides a 10× higher sensitivity than color visualization. We demonstrated a practical use of this thermometric immunoassay with rapid antigen tests for COVID-19.
Collapse
Affiliation(s)
- Terumitsu Azuma
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC.,Department of Physics, National Taiwan University, Taipei, 106, Taiwan, ROC
| | - Yuen Yung Hui
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC
| | - Oliver Y Chen
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC
| | - Yuh-Lin Wang
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC.,Department of Physics, National Taiwan University, Taipei, 106, Taiwan, ROC
| | - Huan-Cheng Chang
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC. .,Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC. .,Department of Chemistry, National Taiwan Normal University, Taipei, 106, Taiwan, ROC.
| |
Collapse
|