1
|
Lee HK, Yang YJ, Koirala GR, Oh S, Kim TI. From lab to wearables: Innovations in multifunctional hydrogel chemistry for next-generation bioelectronic devices. Biomaterials 2024; 310:122632. [PMID: 38824848 DOI: 10.1016/j.biomaterials.2024.122632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 05/19/2024] [Accepted: 05/23/2024] [Indexed: 06/04/2024]
Abstract
Functional hydrogels have emerged as foundational materials in diagnostics, therapy, and wearable devices, owing to their high stretchability, flexibility, sensing, and outstanding biocompatibility. Their significance stems from their resemblance to biological tissue and their exceptional versatility in electrical, mechanical, and biofunctional engineering, positioning themselves as a bridge between living organisms and electronic systems, paving the way for the development of highly compatible, efficient, and stable interfaces. These multifaceted capability revolutionizes the essence of hydrogel-based wearable devices, distinguishing them from conventional biomedical devices in real-world practical applications. In this comprehensive review, we first discuss the fundamental chemistry of hydrogels, elucidating their distinct properties and functionalities. Subsequently, we examine the applications of these bioelectronics within the human body, unveiling their transformative potential in diagnostics, therapy, and human-machine interfaces (HMI) in real wearable bioelectronics. This exploration serves as a scientific compass for researchers navigating the interdisciplinary landscape of chemistry, materials science, and bioelectronics.
Collapse
Affiliation(s)
- Hin Kiu Lee
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Ye Ji Yang
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Gyan Raj Koirala
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea; Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Suyoun Oh
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea; Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea.
| |
Collapse
|
2
|
Hong S, Yu T, Wang Z, Lee CH. Biomaterials for reliable wearable health monitoring: Applications in skin and eye integration. Biomaterials 2024; 314:122862. [PMID: 39357154 DOI: 10.1016/j.biomaterials.2024.122862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 09/22/2024] [Accepted: 09/26/2024] [Indexed: 10/04/2024]
Abstract
Recent advancements in biomaterials have significantly impacted wearable health monitoring, creating opportunities for personalized and non-invasive health assessments. These developments address the growing demand for customized healthcare solutions. Durability is a critical factor for biomaterials in wearable applications, as they must withstand diverse wearing conditions effectively. Therefore, there is a heightened focus on developing biomaterials that maintain robust and stable functionalities, essential for advancing wearable sensing technologies. This review examines the biomaterials used in wearable sensors, specifically those interfaced with human skin and eyes, highlighting essential strategies for achieving long-lasting and stable performance. We specifically discuss three main categories of biomaterials-hydrogels, fibers, and hybrid materials-each offering distinct properties ideal for use in durable wearable health monitoring systems. Moreover, we delve into the latest advancements in biomaterial-based sensors, which hold the potential to facilitate early disease detection, preventative interventions, and tailored healthcare approaches. We also address ongoing challenges and suggest future directions for research on material-based wearable sensors to encourage continuous innovation in this dynamic field.
Collapse
Affiliation(s)
- Seokkyoon Hong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Tianhao Yu
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Ziheng Wang
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Chi Hwan Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, 47907, USA; School of Mechanical Engineering, Purdue University, West Lafayette, IN, 47907, USA; Center for Implantable Devices, Purdue University, West Lafayette, IN, 47907, USA; School of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA; Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
3
|
Liu W, Du Z, Duan Z, Li L, Shen G. Neuroprosthetic contact lens enabled sensorimotor system for point-of-care monitoring and feedback of intraocular pressure. Nat Commun 2024; 15:5635. [PMID: 38965218 PMCID: PMC11224243 DOI: 10.1038/s41467-024-49907-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 06/24/2024] [Indexed: 07/06/2024] Open
Abstract
The wearable contact lens that continuously monitors intraocular pressure (IOP) facilitates prompt and early-state medical treatments of oculopathies such as glaucoma, postoperative myopia, etc. However, either taking drugs for pre-treatment or delaying the treatment process in the absence of a neural feedback component cannot realize accurate diagnosis or effective treatment. Herein, a neuroprosthetic contact lens enabled sensorimotor system is reported, which consists of a smart contact lens with Ti3C2Tx Wheatstone bridge structured IOP strain sensor, a Ti3C2Tx temperature sensor and an IOP point-of-care monitoring/display system. The point-of-care IOP monitoring and warning can be realized due to the high sensitivity of 12.52 mV mmHg-1 of the neuroprosthetic contact lens. In vivo experiments on rabbit eyes demonstrate the excellent wearability and biocompatibility of the neuroprosthetic contact lens. Further experiments on a living rate in vitro successfully mimic the biological sensorimotor loop. The leg twitching (larger or smaller angles) of the living rat was demonstrated under the command of motor cortex controlled by somatosensory cortex when the IOP is away from the normal range (higher or lower).
Collapse
Affiliation(s)
- Weijia Liu
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, 100081, Beijing, China
| | - Zhijian Du
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, 100081, Beijing, China
| | - Zhongyi Duan
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, 100081, Beijing, China
| | - La Li
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, 100081, Beijing, China.
| | - Guozhen Shen
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, 100081, Beijing, China.
| |
Collapse
|
4
|
Wu KY, Dave A, Carbonneau M, Tran SD. Smart Contact Lenses in Ophthalmology: Innovations, Applications, and Future Prospects. MICROMACHINES 2024; 15:856. [PMID: 39064367 PMCID: PMC11279085 DOI: 10.3390/mi15070856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Revised: 06/26/2024] [Accepted: 06/28/2024] [Indexed: 07/28/2024]
Abstract
Smart contact lenses represent a breakthrough in the intersection of medical science and innovative technology, offering transformative potential in ophthalmology. This review article delves into the technological underpinnings of smart contact lenses, emphasizing the current landscape and advancements in biosensors, power supply, biomaterials, and the transmission of ocular information. This review further applies new innovations to their emerging role in the diagnosis, monitoring, and management of various ocular conditions. Moreover, we explore the impact of technical innovations on the application of smart contact lenses in monitoring glaucoma, managing postoperative care, and dry eye syndrome, further elucidating the non-invasive nature of these devices in continuous ocular health monitoring. The therapeutic potential of smart contact lenses such as treatment through targeted drug delivery and the monitoring of inflammatory biomarkers is also highlighted. Despite promising advancements, the implementation of smart contact lenses faces technical, regulatory, and patient compliance challenges. This review synthesizes the recent advances to provide an outlook on the state of smart contact lens technology. Furthermore, we discuss future directions, focusing on potential technological enhancements and new applications within ophthalmology.
Collapse
Affiliation(s)
- Kevin Y. Wu
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Archan Dave
- Department of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada
| | - Marjorie Carbonneau
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Simon D. Tran
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC H3A 1G1, Canada
| |
Collapse
|
5
|
Cheng Y, Zhan Y, Guan F, Shi J, Wang J, Sun Y, Zubair M, Yu C, Guo CF. Displacement-pressure biparametrically regulated softness sensory system for intraocular pressure monitoring. Natl Sci Rev 2024; 11:nwae050. [PMID: 38707205 PMCID: PMC11067962 DOI: 10.1093/nsr/nwae050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/16/2024] [Accepted: 01/29/2024] [Indexed: 05/07/2024] Open
Abstract
High intraocular pressure (IOP) is one of the high-risk pathogenic factors of glaucoma. Existing methods of IOP measurement are based on the direct interaction with the cornea. Commercial ophthalmic tonometers based on snapshot measurements are expensive, bulky, and their operation requires trained personnel. Theranostic contact lenses are easy to use, but they may block vision and cause infection. Here, we report a sensory system for IOP assessment that uses a soft indentor with two asymmetrically deployed iontronic flexible pressure sensors to interact with the eyelid-eyeball in an eye-closed situation. Inspired by human fingertip assessment of softness, the sensory system extracts displacement-pressure information for soft evaluation, achieving high accuracy IOP monitoring (>96%). We further design and custom-make a portable and wearable ophthalmic tonometer based on the sensory system and demonstrate its high efficacy in IOP screening. This sensory system paves a way towards cost-effective, robust, and reliable IOP monitoring.
Collapse
Affiliation(s)
- Yu Cheng
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Yifei Zhan
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Fangyi Guan
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Junli Shi
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Jingxiao Wang
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Yi Sun
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| | - Muhammad Zubair
- Department of Engineering Science and Mechanics, Pennsylvania State University, State College 16802, USA
| | - Cunjiang Yu
- Department of Engineering Science and Mechanics, Pennsylvania State University, State College 16802, USA
- Department of Biomedical Engineering, Pennsylvania State University, State College 16802, USA
- Department of Materials Science and Engineering, Materials Research Institute, Pennsylvania State University, State College 16802, USA
| | - Chuan Fei Guo
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| |
Collapse
|
6
|
Li X, Chen W, Li H, Shen B, He J, Gao H, Bin F, Li H, Xiao D. Temperature Self-Compensating Intelligent Wireless Measuring Contact Lens for Quantitative Intraocular Pressure Monitoring. ACS APPLIED MATERIALS & INTERFACES 2024; 16:22522-22531. [PMID: 38651323 DOI: 10.1021/acsami.4c02289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.
Collapse
Affiliation(s)
- Xu Li
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Wei Chen
- Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
- Beijing University of Technology, Beijing 100124, China
| | - Hongyang Li
- Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Biwen Shen
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Jiangang He
- Avic Chengdu Aircraft Design & Research Institute, Chengdu 610041, China
| | - Huanlin Gao
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Fengjiao Bin
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Hui Li
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Dengbao Xiao
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
7
|
Baghban R, Talebnejad MR, Meshksar A, Heydari M, Khalili MR. Recent advancements in nanomaterial-laden contact lenses for diagnosis and treatment of glaucoma, review and update. J Nanobiotechnology 2023; 21:402. [PMID: 37919748 PMCID: PMC10621182 DOI: 10.1186/s12951-023-02166-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 10/18/2023] [Indexed: 11/04/2023] Open
Abstract
Despite the existence of numerous eye drops in the market, most of them are not sufficiently effective because of quick clearance and the barriers within the eye. To increase the delivery of the drugs to the eye, various new formulations have been explored in recent decades. These formulations aim to enhance drug retention and penetration, while enabling sustained drug release over extended periods. One such innovative approach is the utilization of contact lenses, which were originally designed for cosmetic purposes and vision correction. Contact lenses have appeared as a promising formulation for ocular drug delivery, as they can increase the bioavailability of drugs in the eye and diminish unwanted side effects. They are specifically appropriate for treating chronic eye conditions, making them an area of interest for researchers in the field of ophthalmology. This review outlines the promising potential of nanomaterial-laden contact lenses for diagnosis and treatment of glaucoma. It classifies therapeutic approaches based on nanomaterial type, summarizes diagnostic advances, discusses improvement of contact lenses properties, covers marketing perspectives, and acknowledges the challenges of these innovative contact lenses for glaucoma management.
Collapse
Affiliation(s)
- Roghayyeh Baghban
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Reza Talebnejad
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Aidin Meshksar
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mojtaba Heydari
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Reza Khalili
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
8
|
Kim TY, Hong SH, Jeong SH, Bae H, Cheong S, Choi H, Hahn SK. Multifunctional Intelligent Wearable Devices Using Logical Circuits of Monolithic Gold Nanowires. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2303401. [PMID: 37499253 DOI: 10.1002/adma.202303401] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/25/2023] [Indexed: 07/29/2023]
Abstract
Although multifunctional wearable devices have been widely investigated for healthcare systems, augmented/virtual realities, and telemedicines, there are few reports on multiple signal monitoring and logical signal processing by using one single nanomaterial without additional algorithms or rigid application-specific integrated circuit chips. Here, multifunctional intelligent wearable devices are developed using monolithically patterned gold nanowires for both signal monitoring and processing. Gold bulk and hollow nanowires show distinctive electrical properties with high chemical stability and high stretchability. In accordance, the monolithically patterned gold nanowires can be used to fabricate the robust interfaces, programmable sensors, on-demand heating systems, and strain-gated logical circuits. The stretchable sensors show high sensitivity for strain and temperature changes on the skin. Furthermore, the micro-wrinkle structures of gold nanowires exhibit the negative gauge factor, which can be used for strain-gated logical circuits. Taken together, this multifunctional intelligent wearable device would be harnessed as a promising platform for futuristic electronic and biomedical applications.
Collapse
Affiliation(s)
- Tae Yeon Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, South Korea
| | - Sang Hoon Hong
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, South Korea
| | - Sang Hoon Jeong
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, South Korea
| | - Hanseo Bae
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, South Korea
| | - Sunah Cheong
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, South Korea
| | - Hyunsik Choi
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Baldiri i Reixac 10-12, Barcelona, 08028, Spain
| | - Sei Kwang Hahn
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, South Korea
| |
Collapse
|
9
|
Kazanskiy NL, Khonina SN, Butt MA. Smart Contact Lenses-A Step towards Non-Invasive Continuous Eye Health Monitoring. BIOSENSORS 2023; 13:933. [PMID: 37887126 PMCID: PMC10605521 DOI: 10.3390/bios13100933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/10/2023] [Accepted: 10/17/2023] [Indexed: 10/28/2023]
Abstract
According to the age-old adage, while eyes are often considered the gateway to the soul, they might also provide insights into a more pragmatic aspect of our health: blood sugar levels. This potential breakthrough could be realized through the development of smart contact lenses (SCLs). Although contact lenses were first developed for eyesight correction, new uses have recently become available. In the near future, it might be possible to monitor a variety of ocular and systemic disorders using contact lens sensors. Within the realm of glaucoma, SCLs present a novel prospect, offering a potentially superior avenue compared to traditional management techniques. These lenses introduce the possibility of non-invasive and continuous monitoring of intraocular pressure (IOP) while also enabling the personalized administration of medication as and when needed. This convergence holds great promise for advancing glaucoma care. In this review, recent developments in SCLs, including their potential applications, such as IOP and glucose monitoring, are briefly discussed.
Collapse
Affiliation(s)
- Nikolay L. Kazanskiy
- Samara National Research University, 443086 Samara, Russia
- IPSI RAS-Branch of the FSRC “Crystallography and Photonics” RAS, 443001 Samara, Russia
| | - Svetlana N. Khonina
- Samara National Research University, 443086 Samara, Russia
- IPSI RAS-Branch of the FSRC “Crystallography and Photonics” RAS, 443001 Samara, Russia
| | | |
Collapse
|
10
|
Seo H, Chung WG, Kwon YW, Kim S, Hong YM, Park W, Kim E, Lee J, Lee S, Kim M, Lim K, Jeong I, Song H, Park JU. Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management. Chem Rev 2023; 123:11488-11558. [PMID: 37748126 PMCID: PMC10571045 DOI: 10.1021/acs.chemrev.3c00290] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Indexed: 09/27/2023]
Abstract
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
Collapse
Affiliation(s)
- Hunkyu Seo
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Won Gi Chung
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Yong Won Kwon
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Sumin Kim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Yeon-Mi Hong
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Wonjung Park
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Enji Kim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Jakyoung Lee
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Sanghoon Lee
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Moohyun Kim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Kyeonghee Lim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Inhea Jeong
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Hayoung Song
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Jang-Ung Park
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
- Department
of Neurosurgery, Yonsei University College
of Medicine, Seoul 03722, Republic of Korea
- Center
for Nanomedicine, Institute for Basic Science (IBS), Yonsei University, Seoul 03722, Republic
of Korea
| |
Collapse
|
11
|
Wu KY, Mina M, Carbonneau M, Marchand M, Tran SD. Advancements in Wearable and Implantable Intraocular Pressure Biosensors for Ophthalmology: A Comprehensive Review. MICROMACHINES 2023; 14:1915. [PMID: 37893352 PMCID: PMC10609220 DOI: 10.3390/mi14101915] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/27/2023] [Accepted: 09/28/2023] [Indexed: 10/29/2023]
Abstract
Glaucoma, marked by its intricate association with intraocular pressure (IOP), stands as a predominant cause of non-reversible vision loss. In this review, the physiological relevance of IOP is detailed, alongside its potential pathological consequences. The review further delves into innovative engineering solutions for IOP monitoring, highlighting the latest advancements in wearable and implantable sensors and their potential in enhancing glaucoma management. These technological innovations are interwoven with clinical practice, underscoring their real-world applications, patient-centered strategies, and the prospects for future development in IOP control. By synthesizing theoretical concepts, technological innovations, and practical clinical insights, this review contributes a cohesive and comprehensive perspective on the IOP biosensor's role in glaucoma, serving as a reference for ophthalmological researchers, clinicians, and professionals.
Collapse
Affiliation(s)
- Kevin Y. Wu
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Mina Mina
- Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
| | - Marjorie Carbonneau
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Michael Marchand
- Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada; (K.Y.W.)
| | - Simon D. Tran
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC H3A 1G1, Canada
| |
Collapse
|
12
|
Raveendran R, Prabakaran L, Senthil R, Yesudhason BV, Dharmalingam S, Sathyaraj WV, Atchudan R. Current Innovations in Intraocular Pressure Monitoring Biosensors for Diagnosis and Treatment of Glaucoma-Novel Strategies and Future Perspectives. BIOSENSORS 2023; 13:663. [PMID: 37367028 DOI: 10.3390/bios13060663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/11/2023] [Accepted: 06/14/2023] [Indexed: 06/28/2023]
Abstract
Biosensors are devices that quantify biologically significant information required for diverse applications, such as disease diagnosis, food safety, drug discovery and detection of environmental pollutants. Recent advancements in microfluidics, nanotechnology and electronics have led to the development of novel implantable and wearable biosensors for the expedient monitoring of diseases such as diabetes, glaucoma and cancer. Glaucoma is an ocular disease which ranks as the second leading cause for loss of vision. It is characterized by the increase in intraocular pressure (IOP) in human eyes, which results in irreversible blindness. Currently, the reduction of IOP is the only treatment used to manage glaucoma. However, the success rate of medicines used to treat glaucoma is quite minimal due to their curbed bioavailability and reduced therapeutic efficacy. The drugs must pass through various barriers to reach the intraocular space, which in turn serves as a major challenge in glaucoma treatment. Rapid progress has been observed in nano-drug delivery systems for the early diagnosis and prompt therapy of ocular diseases. This review gives a deep insight into the current advancements in the field of nanotechnology for detecting and treating glaucoma, as well as for the continuous monitoring of IOP. Various nanotechnology-based achievements, such as nanoparticle/nanofiber-based contact lenses and biosensors that can efficiently monitor IOP for the efficient detection of glaucoma, are also discussed.
Collapse
Affiliation(s)
- Rubiya Raveendran
- Faculty of Allied Health Sciences, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education, Kelambakkam 603103, Tamil Nadu, India
| | - Lokesh Prabakaran
- Faculty of Allied Health Sciences, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education, Kelambakkam 603103, Tamil Nadu, India
| | - Rethinam Senthil
- Department of Pharmacology, Saveetha Dental College and Hospitals, SIMATS, Chennai 600077, Tamil Nadu, India
| | - Beryl Vedha Yesudhason
- Regeneration and Stem Cell Biology Lab, Centre for Molecular and Nanomedical Sciences, International Research Centre, Sathyabama Institute of Science and Technology, Chennai 600119, Tamil Nadu, India
| | - Sankari Dharmalingam
- Department of Biotechnology, College of Science and Humanities, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Weslen Vedakumari Sathyaraj
- Faculty of Allied Health Sciences, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education, Kelambakkam 603103, Tamil Nadu, India
| | - Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
- Department of Chemistry, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai 602105, Tamil Nadu, India
| |
Collapse
|
13
|
Ren X, Zhou Y, Lu F, Zhai L, Wu H, Chen Z, Wang C, Zhu X, Xie Y, Cai P, Xu J, Tang X, Li J, Yao J, Jiang Q, Hu B. Contact Lens Sensor with Anti-jamming Capability and High Sensitivity for Intraocular Pressure Monitoring. ACS Sens 2023. [PMID: 37262351 DOI: 10.1021/acssensors.3c00542] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Contact lens sensors provide a noninvasive approach for intraocular pressure (IOP) monitoring in patients with glaucoma. Accurate measurement of this imperceptible pressure variation requires highly sensitive sensors in the absence of simultaneously amplifying IOP signal and blinking-induced noise. However, current noise-reduction methods rely on external filter circuits, which thicken contact lenses and reduce signal quality. Here, we introduce a contact lens strain sensor with an anti-jamming ability by utilizing a self-lubricating layer to reduce the coefficient of friction (COF) to remove the interference from the tangential force. The sensor achieves exceptionally high sensitivity due to the strain concentration layout and the confined occurrence of sympatric microcracks. The animal tests prove our lens can accurately detect IOP safely and reliably.
Collapse
Affiliation(s)
- Xueyang Ren
- Department of Neuro-Psychiatric Institute, the Affiliated Brain Hospital with Nanjing Medical University, Nanjing 210029, China
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
- State Key Laboratory of Bioelectronics and Jiangsu Key Laboratory of Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Yunfan Zhou
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
- The Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Fangzhou Lu
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Leili Zhai
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Hao Wu
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Zhongda Chen
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Changxian Wang
- Innovative Center for Flexible Devices (iFLEX), Max Planck-NTU Joint Lab for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Xuefei Zhu
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
- The Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Yandong Xie
- Department of Neuro-Psychiatric Institute, the Affiliated Brain Hospital with Nanjing Medical University, Nanjing 210029, China
| | - Pingqiang Cai
- Jiangsu Key Laboratory of Molecular Medicine, Medical School, Nanjing University, Nanjing 210093, China
| | - Juan Xu
- Jiangsu Key Laboratory of Molecular Medicine, Medical School, Nanjing University, Nanjing 210093, China
| | - Xianglong Tang
- Department of Neuro-Psychiatric Institute, the Affiliated Brain Hospital with Nanjing Medical University, Nanjing 210029, China
| | - Jianqing Li
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
- School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
| | - Jin Yao
- The Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Qin Jiang
- The Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Benhui Hu
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
- State Key Laboratory of Bioelectronics and Jiangsu Key Laboratory of Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
- The Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210029, China
| |
Collapse
|
14
|
Chen Z, Nguyen K, Kowalik G, Shi X, Tian J, Doshi M, Alber BR, Guan X, Liu X, Ning X, Kay MW, Lu L. Transparent and Stretchable Au─Ag Nanowire Recording Microelectrode Arrays. ADVANCED MATERIALS TECHNOLOGIES 2023; 8:2201716. [PMID: 38644939 PMCID: PMC11031257 DOI: 10.1002/admt.202201716] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Indexed: 04/23/2024]
Abstract
Transparent microelectrodes have received much attention from the biomedical community due to their unique advantages in concurrent crosstalk-free electrical and optical interrogation of cell/tissue activity. Despite recent progress in constructing transparent microelectrodes, a major challenge is to simultaneously achieve desirable mechanical stretchability, optical transparency, electrochemical performance, and chemical stability for high-fidelity, conformal, and stable interfacing with soft tissue/organ systems. To address this challenge, we have designed microelectrode arrays (MEAs) with gold-coated silver nanowires (Au─Ag NWs) by combining technical advances in materials, fabrication, and mechanics. The Au coating improves both the chemical stability and electrochemical impedance of the Au─Ag NW microelectrodes with only slight changes in optical properties. The MEAs exhibit a high optical transparency >80% at 550 nm, a low normalized 1 kHz electrochemical impedance of 1.2-7.5 Ω cm2, stable chemical and electromechanical performance after exposure to oxygen plasma for 5 min, and cyclic stretching for 600 cycles at 20% strain, superior to other transparent microelectrode alternatives. The MEAs easily conform to curvilinear heart surfaces for colocalized electrophysiological and optical mapping of cardiac function. This work demonstrates that stretchable transparent metal nanowire MEAs are promising candidates for diverse biomedical science and engineering applications, particularly under mechanically dynamic conditions.
Collapse
Affiliation(s)
- Zhiyuan Chen
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Khanh Nguyen
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Grant Kowalik
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Xinyu Shi
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Jinbi Tian
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Mitansh Doshi
- Department of Aerospace Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Bridget R Alber
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Xun Guan
- Department of Civil and Environmental Engineering, The George Washington University, Washington, DC 20052, USA
| | - Xitong Liu
- Department of Civil and Environmental Engineering, The George Washington University, Washington, DC 20052, USA
| | - Xin Ning
- Department of Aerospace Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Matthew W Kay
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| | - Luyao Lu
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA
| |
Collapse
|
15
|
Smith AA, Li R, Tse ZTH. Reshaping healthcare with wearable biosensors. Sci Rep 2023; 13:4998. [PMID: 36973262 PMCID: PMC10043012 DOI: 10.1038/s41598-022-26951-z] [Citation(s) in RCA: 34] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 12/22/2022] [Indexed: 03/29/2023] Open
Abstract
Wearable health sensors could monitor the wearer's health and surrounding environment in real-time. With the development of sensor and operating system hardware technology, the functions of wearable devices have been gradually enriched with more diversified forms and more accurate physiological indicators. These sensors are moving towards high precision, continuity, and comfort, making great contributions to improving personalized health care. At the same time, in the context of the rapid development of the Internet of Things, the ubiquitous regulatory capabilities have been released. Some sensor chips are equipped with data readout and signal conditioning circuits, and a wireless communication module for transmitting data to computer equipment. At the same time, for data analysis of wearable health sensors, most companies use artificial neural networks (ANN). In addition, artificial neural networks could help users effectively get relevant health feedback. Through the physiological response of the human body, various sensors worn could effectively transmit data to the control unit, which analyzes the data and provides feedback of the health value to the user through the computer. This is the working principle of wearable sensors for health. This article focuses on wearable biosensors used for healthcare monitoring in different situations, as well as the development, technology, business, ethics, and future of wearable sensors for health monitoring.
Collapse
Affiliation(s)
- Aaron Asael Smith
- College of Engineering, University of Georgia, Athens, GA, 30602, USA
| | - Rui Li
- Tandon School of Engineering, New York University, New York, NY, 11201, USA
| | - Zion Tsz Ho Tse
- Department of Engineering and Material Science, Queen Mary University of London, London, E1 4NS, UK.
| |
Collapse
|
16
|
Kim TY, Lee GH, Mun J, Cheong S, Choi I, Kim H, Hahn SK. Smart Contact Lens Systems for Ocular Drug Delivery and Therapy. Adv Drug Deliv Rev 2023; 196:114817. [PMID: 37004938 DOI: 10.1016/j.addr.2023.114817] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 03/27/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023]
Abstract
Ocular drug delivery and therapy systems have been extensively investigated with various methods including direct injections, eye drops and contact lenses. Nowadays, smart contact lens systems are attracting a lot of attention for ocular drug delivery and therapy due to their minimally invasive or non-invasive characteristics, highly enhanced drug permeation, high bioavailability, and on-demand drug delivery. Furthermore, smart contact lens systems can be used for direct light delivery into the eyes for biophotonic therapy replacing the use of drugs. Here, we review smart contact lens systems which can be classified into two groups of drug-eluting contact lens and ocular device contact lens. More specifically, this review covers smart contact lens systems with nanocomposite-laden systems, polymeric film-incorporated systems, micro and nanostructure systems, iontophoretic systems, electrochemical systems, and phototherapy systems for ocular drug delivery and therapy. After that, we discuss the future opportunities, challenges and perspectives of smart contact lens systems for ocular drug delivery and therapy.
Collapse
Affiliation(s)
- Tae Yeon Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Geon-Hui Lee
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Jonghwan Mun
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Sunah Cheong
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Inhoo Choi
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Hyemin Kim
- Department of Cosmetics Engineering, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05029, Republic of Korea.
| | - Sei Kwang Hahn
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Republic of Korea; PHI BIOMED Co., 168 Yeoksam-ro, Gangnamgu, Seoul 06248, Republic of Korea.
| |
Collapse
|
17
|
Kim TY, Mok JW, Hong SH, Jeong SH, Choi H, Shin S, Joo CK, Hahn SK. Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma. Nat Commun 2022; 13:6801. [PMID: 36357417 PMCID: PMC9649789 DOI: 10.1038/s41467-022-34597-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 10/31/2022] [Indexed: 11/12/2022] Open
Abstract
Glaucoma is one of the irreversible ocular diseases that can cause vision loss in some serious cases. Although Triggerfish has been commercialized for monitoring intraocular pressure in glaucoma, there is no smart contact lens to monitor intraocular pressure and take appropriate drug treatment in response to the intraocular pressure levels. Here, we report a precisely integrated theranostic smart contact lens with a sensitive gold hollow nanowire based intraocular pressure sensor, a flexible drug delivery system, wireless power and communication systems and an application specific integrated circuit chip for both monitoring and control of intraocular pressure in glaucoma. The gold hollow nanowire based intraocular pressure sensor shows high ocular strain sensitivity, chemical stability and biocompatibility. Furthermore, the flexible drug delivery system can be used for on-demand delivery of timolol for intraocular pressure control. Taken together, the intraocular pressure levels can be successfully monitored and controlled by the theranostic smart contact lens in glaucoma induced rabbits. This theranostic smart contact lens would be harnessed as a futuristic personal healthcare platform for glaucoma and other ocular diseases.
Collapse
Affiliation(s)
- Tae Yeon Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Korea
| | - Jee Won Mok
- CK St. Mary's Eye Center, CK building, 559, Gangnam-daero, Seocho-gu, Seoul, 06531, Korea
| | - Sang Hoon Hong
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Korea
| | - Sang Hoon Jeong
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Korea
| | - Hyunsik Choi
- PHI BIOMED Co., 168, Yeoksam-ro, Gangnam-gu, Seoul, 06248, Korea
| | - Sangbaie Shin
- PHI BIOMED Co., 168, Yeoksam-ro, Gangnam-gu, Seoul, 06248, Korea
| | - Choun-Ki Joo
- CK St. Mary's Eye Center, CK building, 559, Gangnam-daero, Seocho-gu, Seoul, 06531, Korea
| | - Sei Kwang Hahn
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Korea.
- PHI BIOMED Co., 168, Yeoksam-ro, Gangnam-gu, Seoul, 06248, Korea.
| |
Collapse
|
18
|
Mun J, Kim TY, Myung D, Hahn SK. Smart contact lens containing hyaluronate-rose bengal conjugate for biophotonic myopia vision correction. Biomater Sci 2022; 10:4997-5005. [PMID: 35815427 DOI: 10.1039/d2bm00584k] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
As the collagen layer weakens with increasing age or certain diseases such as keratoconus and myopia, the mechanical property of the collagen layer decreases with corneal deformation. To circumvent these problems, the corneal collagen has been crosslinked with the photosensitizer riboflavin under UV light after de-epithelialization. However, this treatment with riboflavin and UV light can cause notable damage to the eye. Here, the biocompatible rose bengal (RB) dye was conjugated to hyaluronic acid (HA) to enhance the corneal permeability, which can be activated by safe green light with a wavelength of 530 nm. Two-photon microscopy revealed the deep tissue penetration of the HA-RB conjugate in comparison with RB. Collagen fibrillogenesis, ex vivo tensile test, and ex vivo histological analysis confirmed the effective collagen crosslinking by HA-RB conjugate and the light irradiation. Furthermore, we developed a smart contact lens for on-demand HA-RB conjugate delivery from the reservoir embedded in the contact lens. Taken together, we could envision the feasibility of a smart contact lens for biophotonic myopia vision correction.
Collapse
Affiliation(s)
- Jonghwan Mun
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea.
| | - Tae Yeon Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea.
| | - David Myung
- Department of Chemical Engineering, Stanford University, Stanford, CA, USA.,Byers Eye Institute at Stanford University School of Medicine, Palo Alto, CA, USA
| | - Sei Kwang Hahn
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673, Korea.
| |
Collapse
|
19
|
Zhu Y, Li S, Li J, Falcone N, Cui Q, Shah S, Hartel MC, Yu N, Young P, de Barros NR, Wu Z, Haghniaz R, Ermis M, Wang C, Kang H, Lee J, Karamikamkar S, Ahadian S, Jucaud V, Dokmeci MR, Kim HJ, Khademhosseini A. Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2108389. [PMID: 35130584 PMCID: PMC9233032 DOI: 10.1002/adma.202108389] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 01/27/2022] [Indexed: 05/09/2023]
Abstract
The eye is one of the most complex organs in the human body, containing rich and critical physiological information (e.g., intraocular pressure, corneal temperature, and pH) as well as a library of metabolite biomarkers (e.g., glucose, proteins, and specific ions). Smart contact lenses (SCLs) can serve as a wearable intelligent ocular prosthetic device capable of noninvasive and continuous monitoring of various essential physical/biochemical parameters and drug loading/delivery for the treatment of ocular diseases. Advances in SCL technologies and the growing public interest in personalized health are accelerating SCL research more than ever before. Here, the current status and potential of SCL development through a comprehensive review from fabrication to applications to commercialization are discussed. First, the material, fabrication, and platform designs of the SCLs for the diagnostic and therapeutic applications are discussed. Then, the latest advances in diagnostic and therapeutic SCLs for clinical translation are reviewed. Later, the established techniques for wearable power transfer and wireless data transmission applied to current SCL devices are summarized. An outlook, future opportunities, and challenges for developing next-generation SCL devices are also provided. With the rise in interest of SCL development, this comprehensive and essential review can serve as a new paradigm for the SCL devices.
Collapse
Affiliation(s)
- Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Shaopei Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Jinghang Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- School of Engineering, Westlake University, Hangzhou, Zhejiang Province, 310024, China
- School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan, Hubei Province, 430205, China
| | - Natashya Falcone
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Qingyu Cui
- Department of Medicine, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | - Shilp Shah
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | - Martin C Hartel
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | - Ning Yu
- Department of Chemical and Environmental Engineering, University of California-Riverside, Riverside, CA, 92521, USA
| | - Patric Young
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | | | - Zhuohong Wu
- Department of Nanoengineering, University of California-San Diego, San Diego, CA, 92093, USA
| | - Reihaneh Haghniaz
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Menekse Ermis
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Canran Wang
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Heemin Kang
- Department of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Junmin Lee
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea
| | | | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Vadim Jucaud
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Mehmet R Dokmeci
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Han-Jun Kim
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| |
Collapse
|
20
|
Lee G, Jeon C, Mok JW, Shin S, Kim S, Han HH, Kim S, Hong SH, Kim H, Joo C, Sim J, Hahn SK. Smart Wireless Near-Infrared Light Emitting Contact Lens for the Treatment of Diabetic Retinopathy. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2103254. [PMID: 35092362 PMCID: PMC8948592 DOI: 10.1002/advs.202103254] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 12/30/2021] [Indexed: 05/04/2023]
Abstract
Diabetic retinopathy is currently treated by highly invasive repeated therapeutic injections and surgical interventions without complete vision recovery. Here, a noninvasive smart wireless far red/near-infrared (NIR) light emitting contact lens developed successfully for the repeated treatment of diabetic retinopathy with significantly improved compliance. A far red/NIR light emitting diode (LED) is connected with an application-specific integrated circuit chip, wireless power, and communication systems on a PET film, which is embedded in a silicone elastomer contact lens by thermal crosslinking. After in vitro characterization, it is confirmed that the retinal vascular hyper-permeability induced by diabetic retinopathy in rabbits is reduced to a statistically significant level by simply repeated wearing of smart far red/NIR LED contact lens for 8 weeks with 120 µW light irradiation for 15 min thrice a week. Histological analysis exhibits the safety and feasibility of LED contact lenses for treating diabetic retinopathy. This platform technology for smart LED contact lens would be harnessed for various biomedical photonic applications.
Collapse
Affiliation(s)
- Geon‐Hui Lee
- Department of Materials Science and EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Cheonhoo Jeon
- Department of Electrical EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Jee Won Mok
- Department of Ophthalmology and Visual ScienceSeoul St. Mary's HospitalCollege of MedicineThe Catholic University of Korea505, Banpo‐dongSeocho‐guSeoul06591South Korea
| | - Sangbaie Shin
- PHI BIOMED Co.168, Yeoksam‐roGangnam‐guSeoul06248South Korea
| | - Su‐Kyoung Kim
- Department of Materials Science and EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Hye Hyeon Han
- Department of Materials Science and EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Seong‐Jong Kim
- Department of Materials Science and EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Sang Hoon Hong
- Department of Materials Science and EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Hwanhee Kim
- PHI BIOMED Co.168, Yeoksam‐roGangnam‐guSeoul06248South Korea
| | - Choun‐Ki Joo
- Department of Ophthalmology and Visual ScienceSeoul St. Mary's HospitalCollege of MedicineThe Catholic University of Korea505, Banpo‐dongSeocho‐guSeoul06591South Korea
| | - Jae‐Yoon Sim
- Department of Electrical EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| | - Sei Kwang Hahn
- Department of Materials Science and EngineeringPohang University of Science and Technology (POSTECH)77 Cheongam‐ro, Nam‐guPohangGyeongbuk37673South Korea
| |
Collapse
|
21
|
Song S, Kim KY, Lee SH, Kim KK, Lee K, Lee W, Jeon H, Ko SH. Recent Advances in 1D Nanomaterial‐Based Bioelectronics for Healthcare Applications. ADVANCED NANOBIOMED RESEARCH 2021. [DOI: 10.1002/anbr.202100111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Affiliation(s)
- Sangmin Song
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak-ro Gwanak-gu Seoul 151-742 Korea
- Center for Biomaterials Biomedical Research Institute Korea Institute of Science and Technology (KIST) 5, Hwarang-ro 14-gil Seongbuk-gu Seoul 02792 Korea
| | - Kyung Yeun Kim
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak-ro Gwanak-gu Seoul 151-742 Korea
- Center for Biomaterials Biomedical Research Institute Korea Institute of Science and Technology (KIST) 5, Hwarang-ro 14-gil Seongbuk-gu Seoul 02792 Korea
| | - Sun Hee Lee
- Center for Biomaterials Biomedical Research Institute Korea Institute of Science and Technology (KIST) 5, Hwarang-ro 14-gil Seongbuk-gu Seoul 02792 Korea
| | - Kyun Kyu Kim
- Department of Chemical Engineering Stanford University Stanford CA 94305 USA
| | - Kyungwoo Lee
- Center for Biomaterials Biomedical Research Institute Korea Institute of Science and Technology (KIST) 5, Hwarang-ro 14-gil Seongbuk-gu Seoul 02792 Korea
| | - Wonryung Lee
- Center for Biomaterials Biomedical Research Institute Korea Institute of Science and Technology (KIST) 5, Hwarang-ro 14-gil Seongbuk-gu Seoul 02792 Korea
| | - Hojeong Jeon
- Center for Biomaterials Biomedical Research Institute Korea Institute of Science and Technology (KIST) 5, Hwarang-ro 14-gil Seongbuk-gu Seoul 02792 Korea
- KU-KIST Graduate School of Converging Science and Technology Korea University 145, Anam-ro Seongbuk-gu Seoul 02841 Korea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak-ro Gwanak-gu Seoul 151-742 Korea
- Institute of Advanced Machines and Design/Institute of Engineering Research Seoul National University Seoul 08826 Korea
| |
Collapse
|
22
|
Devaraj H, Tian Q, Guo W, Malhotra R. Multiscale Modeling of Sintering-Driven Conductivity in Large Nanowire Ensembles. ACS APPLIED MATERIALS & INTERFACES 2021; 13:56645-56654. [PMID: 34784174 DOI: 10.1021/acsami.1c16581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Thermally driven sintering is widely used to enhance the conductivity of metal nanowire (NW) ensembles in printed electronics applications, with rapid nonisothermal sintering being increasingly employed to minimize substrate damage. The rational design of the sintering process and the NW morphology is hindered by a lack of mechanistically motivated and computationally efficient models that can predict sintering-driven neck growth between NWs and the resulting change in ensemble conductivity. We present a de novo modeling framework that, for the first time, links rotation-regulated nanoscale neck growth observed in atomistic simulations to continuum conductivity evolution in inch-scale NW ensembles via an analytical neck growth model and master curve formulations of neck growth and resistivity. This framework is experimentally validated against the emergent intense pulsed light-sintering process for Ag NWs. An ultralow computational effort of 0.2 CPU-h is achieved, 4-10 orders of magnitude reduction as compared to the state of the art. We show that the inherent local variation in the relative NW orientation within an ensemble drives significant junction-specific differences in neck growth kinetics and junction resistivity. This goes beyond the conventional assumption that the neck growth kinetics is the same at all the NW junctions in an ensemble, with significant implications on how nanoscale neck growth affects ensemble-scale conductivity. Through its low computational time, easy and rapid recalibration, and experimental relevance, our framework constitutes a much-needed foundational enabler for a priori design of the sintering process and the NWs.
Collapse
Affiliation(s)
- Harish Devaraj
- Department of Mechanical & Aerospace Engineering, Rutgers University, 98 Brett Road, Piscataway, New Jersey 08854, United States
| | - Qi Tian
- Department of Industrial and Systems Engineering, Rutgers University, 96 Frelinghuysen Road, Piscataway, New Jersey 08854, United States
| | - Weihong Guo
- Department of Industrial and Systems Engineering, Rutgers University, 96 Frelinghuysen Road, Piscataway, New Jersey 08854, United States
| | - Rajiv Malhotra
- Department of Mechanical & Aerospace Engineering, Rutgers University, 98 Brett Road, Piscataway, New Jersey 08854, United States
| |
Collapse
|
23
|
Enhanced topical corticosteroids delivery to the eye: A trade-off in strategy choice. J Control Release 2021; 339:91-113. [PMID: 34560157 DOI: 10.1016/j.jconrel.2021.09.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/16/2021] [Accepted: 09/18/2021] [Indexed: 12/19/2022]
Abstract
Topical corticosteroids are the primary treatment of ocular inflammation caused by surgery, injury, or other conditions. Drug pre-corneal residence time, drug water solubility, and drug corneal permeability coefficient are the major factors that determine the ocular drug bioavailability after topical administration. Although growing research successfully enhanced local delivery of corticosteroids utilizing various strategies, rational and dynamic approaches to strategy selection are still lacking. Within this review, an overview of the various strategies as well as their performance in retention, solubility, and permeability coefficient of corticosteroids are provided. On this basis, the tradeoff of strategy selection is discussed, which may shed light on the rational choice and application of ophthalmic delivery enhancement strategies.
Collapse
|