1
|
Buskermolen AD, Michielsen CMS, de Jong AM, Prins MWJ. Towards continuous monitoring of TNF-α at picomolar concentrations using biosensing by particle motion. Biosens Bioelectron 2024; 249:115934. [PMID: 38215637 DOI: 10.1016/j.bios.2023.115934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 11/30/2023] [Accepted: 12/13/2023] [Indexed: 01/14/2024]
Abstract
The ability to continuously monitor cytokines is desirable for fundamental research studies and healthcare applications. Cytokine release is characterized by picomolar circulating concentrations, short half-lives, and rapid peak times. Here, we describe the characteristics and feasibility of a particle-based biosensing technique for continuous monitoring of TNF-α at picomolar concentrations. The technique is based on the optical tracking of particle motion and uses an antibody sandwich configuration. Experimental results show how the analyte concentration influences the particle diffusivity and characteristic response time of the sensor, and how the sensitivity range depends on the antibody functionalization density. Furthermore, the data clarifies how antibodies supplemented in solution can shorten the characteristic response time. Finally, we demonstrate association rate-based sensing as a first step towards continuous monitoring of picomolar TNF-α concentrations, over a period of 2 h with delay times under 15 min. The insights from this research will enable the development of continuous monitoring sensors using high-affinity binders, providing the sensitivity and speed needed in applications like cytokine monitoring.
Collapse
Affiliation(s)
- Alissa D Buskermolen
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Claire M S Michielsen
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Arthur M de Jong
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands; Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Menno W J Prins
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands; Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands; Helia Biomonitoring, Eindhoven, the Netherlands.
| |
Collapse
|
2
|
Rana A, Mishra G, Biswas S. Functional Group-Assisted Fluorescence Sensing Platform for Nanomolar-Level Detection of an Antineoplastic Drug and a Neurotransmitter from Environmental Water and Human Biofluids. Inorg Chem 2024; 63:4502-4510. [PMID: 38408375 DOI: 10.1021/acs.inorgchem.3c03341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
A fast, sensitive, selective, and biocompatible dual sensor of an antineoplastic medication (methotrexate) and a neurotransmitter (adrenaline) is still being searched by present-day scientists. To overcome this issue, we have designed a functionalized, robust, bio-friendly luminescent MOF for the sensitive, selective, and rapid monitoring of methotrexate and adrenaline. This probe is the first ever reported MOF-based fluorescence sensor of methotrexate and second only for adrenaline. This fluorescence probe has a very low limit of detection (LOD) of 0.34 and 11.2 nM for adrenaline and methotrexate, respectively. The sensor can detect both the targeted analytes rapidly within 5 s. It can also detect adrenaline and methotrexate from human blood serum and urine accurately and precisely. This reusable sensor is equally efficient in detecting methotrexate from environmental water specimens. Biocompatible, user-friendly, and inexpensive chitosan@MOF@cotton composites were fabricated for the detection of adrenaline and methotrexate from the nanomolar to the micromolar range by the naked eye under a fluorescence lamp. This probe displayed high reproducibility, precision, and accuracy in sensing methotrexate and adrenaline. Fluorescence resonance energy transfer (FRET) and the inner filter effect (IFE) are the possible mechanisms for adrenaline and methotrexate sensing, respectively. The possible mechanism was supported by using required instrumental techniques and theoretical simulations.
Collapse
Affiliation(s)
- Abhijeet Rana
- Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Gyanesh Mishra
- Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Shyam Biswas
- Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| |
Collapse
|
3
|
Watkins Z, McHenry A, Heikenfeld J. Wearing the Lab: Advances and Challenges in Skin-Interfaced Systems for Continuous Biochemical Sensing. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2024; 187:223-282. [PMID: 38273210 DOI: 10.1007/10_2023_238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Continuous, on-demand, and, most importantly, contextual data regarding individual biomarker concentrations exemplify the holy grail for personalized health and performance monitoring. This is well-illustrated for continuous glucose monitoring, which has drastically improved outcomes and quality of life for diabetic patients over the past 2 decades. Recent advances in wearable biosensing technologies (biorecognition elements, transduction mechanisms, materials, and integration schemes) have begun to make monitoring of other clinically relevant analytes a reality via minimally invasive skin-interfaced devices. However, several challenges concerning sensitivity, specificity, calibration, sensor longevity, and overall device lifetime must be addressed before these systems can be made commercially viable. In this chapter, a logical framework for developing a wearable skin-interfaced device for a desired application is proposed with careful consideration of the feasibility of monitoring certain analytes in sweat and interstitial fluid and the current development of the tools available to do so. Specifically, we focus on recent advancements in the engineering of biorecognition elements, the development of more robust signal transduction mechanisms, and novel integration schemes that allow for continuous quantitative analysis. Furthermore, we highlight the most compelling and promising prospects in the field of wearable biosensing and the challenges that remain in translating these technologies into useful products for disease management and for optimizing human performance.
Collapse
Affiliation(s)
- Zach Watkins
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Adam McHenry
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Jason Heikenfeld
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
4
|
Michielsen CS, Buskermolen AD, de Jong AM, Prins MWJ. Sandwich Immunosensor Based on Particle Motion: How Do Reactant Concentrations and Reaction Pathways Determine the Time-Dependent Response of the Sensor? ACS Sens 2023; 8:4216-4225. [PMID: 37955441 PMCID: PMC10683507 DOI: 10.1021/acssensors.3c01549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 09/21/2023] [Accepted: 10/17/2023] [Indexed: 11/14/2023]
Abstract
To control and optimize the speed of a molecular biosensor, it is crucial to quantify and understand the mechanisms that underlie the time-dependent response of the sensor. Here, we study how the kinetic properties of a particle-based sandwich immunosensor depend on underlying parameters, such as reactant concentrations and the size of the reaction chamber. The data of the measured sensor responses could be fitted with single-exponential curves, with characteristic response times that depend on the analyte concentration and the binder concentrations on the particle and substrate. By comparing characteristic response times at different incubation configurations, the data clarifies how two distinct reaction pathways play a role in the sandwich immunosensor, namely, analyte binding first to particles and thereafter to the substrate, and analyte binding first to the substrate and thereafter to a particle. For a concrete biosensor design, we found that the biosensor is dominated by the reaction pathway where analyte molecules bind first to the substrate and thereafter to a particle. Within this pathway, the binding of a particle to the substrate-bound analyte dominates the sensor response time. Thus, the probability of a particle interacting with the substrate was identified as the main direction to improve the speed of the biosensor while maintaining good sensitivity. We expect that the developed immunosensor and research methodology can be generally applied to understand the reaction mechanisms and optimize the kinetic properties of sandwich immunosensors with particle labels.
Collapse
Affiliation(s)
- Claire
M. S. Michielsen
- Department
of Biomedical Engineering, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
| | - Alissa D. Buskermolen
- Department
of Biomedical Engineering, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
| | - Arthur M. de Jong
- Department
of Applied Physics, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
| | - Menno W. J. Prins
- Department
of Biomedical Engineering, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Department
of Applied Physics, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
- Helia
Biomonitoring, Eindhoven 5612 AR, The Netherlands
| |
Collapse
|
5
|
Bergkamp MH, Cajigas S, van IJzendoorn LJ, Prins MWJ. Real-time continuous monitoring of dynamic concentration profiles studied with biosensing by particle motion. LAB ON A CHIP 2023; 23:4600-4609. [PMID: 37772830 DOI: 10.1039/d3lc00410d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/30/2023]
Abstract
Real-time monitoring-and-control of biological systems requires lab-on-a-chip sensors that are able to accurately measure concentration-time profiles with a well-defined time delay and accuracy using only small amounts of sampled fluid. Here, we study real-time continuous monitoring of dynamic concentration profiles in a microfluidic measurement chamber. Step functions and sinusoidal oscillations of concentrations were generated using two pumps and a herringbone mixer. Concentrations in the bulk of the measurement chamber were quantified using a solution with a dye and light absorbance measurements. Concentrations near the surface were measured using a reversible cortisol sensor based on particle motion. The experiments show how the total time delay of the real-time sensor has contributions from advection, diffusion, reaction kinetics at the surface and signal processing. The total time delay of the studied real-time cortisol sensor was ∼90 seconds for measuring 63% of the concentration change. Monitoring of sinusoidal cortisol concentration-time profiles showed that the sensor has a low-pass frequency response with a cutoff frequency of ∼4 mHz and a lag time of ∼60 seconds. The described experimental methodology paves the way for the development of monitoring-and-control in lab-on-a-chip systems and for further engineering of the analytical characteristics of real-time continuous biosensors.
Collapse
Affiliation(s)
- Max H Bergkamp
- Department of Biomedical Engineering, Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands.
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands
| | | | - Leo J van IJzendoorn
- Department of Applied Physics and Science Education, Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands
| | - Menno W J Prins
- Department of Biomedical Engineering, Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands.
- Department of Applied Physics and Science Education, Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands
- Helia Biomonitoring, 5612 AR Eindhoven, The Netherlands
| |
Collapse
|
6
|
Bergkamp MH, Cajigas S, van IJzendoorn LJ, Prins MW. High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing? ACS Sens 2023; 8:2271-2281. [PMID: 37216442 PMCID: PMC10294250 DOI: 10.1021/acssensors.3c00245] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 05/05/2023] [Indexed: 05/24/2023]
Abstract
Single-molecule sensors collect statistics of single-molecule interactions, and the resulting data can be used to determine concentrations of analyte molecules. The assays are generally end-point assays and are not designed for continuous biosensing. For continuous biosensing, a single-molecule sensor needs to be reversible, and the signals should be analyzed in real time in order to continuously report output signals, with a well-controlled time delay and measurement precision. Here, we describe a signal processing architecture for real-time continuous biosensing based on high-throughput single-molecule sensors. The key aspect of the architecture is the parallel computation of multiple measurement blocks that enables continuous measurements over an endless time span. Continuous biosensing is demonstrated for a single-molecule sensor with 10,000 individual particles that are tracked as a function of time. The continuous analysis includes particle identification, particle tracking, drift correction, and detection of the discrete timepoints where individual particles switch between bound and unbound states, yielding state transition statistics that relate to the analyte concentration in solution. The continuous real-time sensing and computation were studied for a reversible cortisol competitive immunosensor, showing how the precision and time delay of cortisol monitoring are controlled by the number of analyzed particles and the size of the measurement blocks. Finally, we discuss how the presented signal processing architecture can be applied to various single-molecule measurement methods, allowing these to be developed into continuous biosensors.
Collapse
Affiliation(s)
- Max H. Bergkamp
- Department
of Biomedical Engineering, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
| | | | - Leo J. van IJzendoorn
- Department
of Applied Physics and Science Education, Eindhoven University of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
| | - Menno W.J. Prins
- Department
of Biomedical Engineering, Eindhoven University
of Technology, Eindhoven 5612 AE, The Netherlands
- Department
of Applied Physics and Science Education, Eindhoven University of Technology, Eindhoven 5612 AE, The Netherlands
- Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, Eindhoven 5612 AE, The Netherlands
- Helia
Biomonitoring, Eindhoven 5612 AR, The Netherlands
| |
Collapse
|
7
|
Kusov PA, Kotelevtsev YV, Drachev VP. Cortisol Monitoring Devices toward Implementation for Clinically Relevant Biosensing In Vivo. Molecules 2023; 28:molecules28052353. [PMID: 36903600 PMCID: PMC10005364 DOI: 10.3390/molecules28052353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 02/23/2023] [Accepted: 02/24/2023] [Indexed: 03/08/2023] Open
Abstract
Cortisol is a steroid hormone that regulates energy metabolism, stress reactions, and immune response. Cortisol is produced in the kidneys' adrenal cortex. Its levels in the circulatory system are regulated by the neuroendocrine system with a negative feedback loop of the hypothalamic-pituitary-adrenal axis (HPA-axis) following circadian rhythm. Conditions associated with HPA-axis disruption cause deteriorative effects on human life quality in numerous ways. Psychiatric, cardiovascular, and metabolic disorders as well as a variety of inflammatory processes accompanying age-related, orphan, and many other conditions are associated with altered cortisol secretion rates and inadequate responses. Laboratory measurements of cortisol are well-developed and based mainly on the enzyme linked immunosorbent assay (ELISA). There is a great demand for a continuous real-time cortisol sensor that is yet to be developed. Recent advances in approaches that will eventually culminate in such sensors have been summarized in several reviews. This review compares different platforms for direct cortisol measurements in biological fluids. The ways to achieve continuous cortisol measurements are discussed. A cortisol monitoring device will be essential for personified pharmacological correction of the HPA-axis toward normal cortisol levels through a 24-h cycle.
Collapse
Affiliation(s)
- Pavel A. Kusov
- Center for Engineering Physics, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
- Correspondence:
| | - Yuri V. Kotelevtsev
- Vladimir Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
| | - Vladimir P. Drachev
- Center for Engineering Physics, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
| |
Collapse
|
8
|
Zhang J, Song C, Zhu Y, Gan H, Fang X, Peng Q, Xiong J, Dong C, Han C, Wang L. A novel cascade signal amplification strategy integrating CRISPR/Cas13a and branched hybridization chain reaction for ultra-sensitive and specific SERS detection of disease-related nucleic acids. Biosens Bioelectron 2023; 219:114836. [PMID: 36327567 DOI: 10.1016/j.bios.2022.114836] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 10/07/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022]
Abstract
The molecular diagnosis of disease by high-sensitively and specifically detecting extremely trace amounts of nucleic acid biomarkers in biological samples is still a great challenge, and the powerful sensing strategy has become an urgent need for basic researches and clinical applications. Herein, a novel one-pot cascade signal amplification strategy (Cas13a-bHCR) integrating CRISPR/Cas13a system (Cas13a) and branched hybridization chain reaction (bHCR) was proposed for ultra-highly sensitive and specific SERS assay of disease-related nucleic acids on SERS-active silver nanorods sensing chips. The Cas13a-bHCR based SERS assay of gastric cancer-related miRNA-106a (miR-106a) can be achieved within 60 min and output significantly enhanced SERS signal due to the multiple signal amplification, which possesses a good linear calibration curve from 10 aM to 1 nM with the limit of detection (LOD) low to 8.55 aM for detecting gastric cancer-related miR-106a in human serum. The Cas13a-bHCR based SERS sensing also shows good specificity, uniformity, repeatability and reliability, and has good practicability for detection of miR-106a in clinical samples, which can provide a potential powerful tool for SERS detection of disease-related nucleic acids and promise brighter prospects in the field of clinical diagnosis of early disease.
Collapse
Affiliation(s)
- Jingjing Zhang
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Chunyuan Song
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China; State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
| | - Yunfeng Zhu
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Hongyu Gan
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Xinyue Fang
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Qian Peng
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Jingrong Xiong
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Chen Dong
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China
| | - Caiqin Han
- Jiangsu Key Laboratory of Advanced Laser Materials and Devices, School of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou, 22116, China.
| | - Lianhui Wang
- State Key Laboratory for Organic Electronics and Information Displays, Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, Nanjing, 210023, China.
| |
Collapse
|
9
|
Pre-equilibrium biosensors as an approach towards rapid and continuous molecular measurements. Nat Commun 2022; 13:7072. [PMID: 36400792 PMCID: PMC9674706 DOI: 10.1038/s41467-022-34778-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Accepted: 11/07/2022] [Indexed: 11/20/2022] Open
Abstract
Almost all biosensors that use ligand-receptor binding operate under equilibrium conditions. However, at low ligand concentrations, the equilibration with the receptor (e.g., antibodies and aptamers) becomes slow and thus equilibrium-based biosensors are inherently limited in making measurements that are both rapid and sensitive. In this work, we provide a theoretical foundation for a method through which biosensors can quantitatively measure ligand concentration before reaching equilibrium. Rather than only measuring receptor binding at a single time-point, the pre-equilibrium approach leverages the receptor's kinetic response to instantaneously quantify the changing ligand concentration. Importantly, by analyzing the biosensor output in frequency domain, rather than in the time domain, we show the degree to which noise in the biosensor affects the accuracy of the pre-equilibrium approach. Through this analysis, we provide the conditions under which the signal-to-noise ratio of the biosensor can be maximized for a given target concentration range and rate of change. As a model, we apply our theoretical analysis to continuous insulin measurement and show that with a properly selected antibody, the pre-equilibrium approach could make the continuous tracking of physiological insulin fluctuations possible.
Collapse
|
10
|
van Smeden L, Saris A, Sergelen K, de Jong AM, Yan J, Prins MWJ. Reversible Immunosensor for the Continuous Monitoring of Cortisol in Blood Plasma Sampled with Microdialysis. ACS Sens 2022; 7:3041-3048. [PMID: 36255855 PMCID: PMC9623578 DOI: 10.1021/acssensors.2c01358] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Cortisol is a steroid hormone involved in a wide range of medical conditions. The level of the hormone fluctuates over time, but with traditional laboratory-based assays, such dynamics cannot be monitored in real time. Here, a reversible cortisol sensor is reported that allows continuous monitoring of cortisol in blood plasma using sampling by microdialysis. The sensor is based on measuring single-molecule binding and unbinding events of tethered particles. The particles are functionalized with antibodies and the substrate with cortisol-analogues, causing binding and unbinding events to occur between particles and substrate. The frequency of binding events is reduced when cortisol is present in the solution as it blocks the binding sites of the antibodies. The sensor responds to cortisol in the high nanomolar to low micromolar range and can monitor cortisol concentrations over multiple hours. Results are shown for cortisol monitoring in filtered and in microdialysis-sampled human blood plasma.
Collapse
Affiliation(s)
- Laura van Smeden
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MBEindhoven, The Netherlands,Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, 5600 MBEindhoven, The Netherlands
| | - Annet Saris
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MBEindhoven, The Netherlands
| | - Khulan Sergelen
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MBEindhoven, The Netherlands,Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, 5600 MBEindhoven, The Netherlands
| | - Arthur M. de Jong
- Department
of Applied Physics, Eindhoven University
of Technology, 5600 MBEindhoven, The Netherlands,Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, 5600 MBEindhoven, The Netherlands
| | - Junhong Yan
- Helia
Biomonitoring, De Lismortel
31, 5612 AREindhoven, The Netherlands
| | - Menno W. J. Prins
- Department
of Biomedical Engineering, Eindhoven University
of Technology, 5600 MBEindhoven, The Netherlands,Department
of Applied Physics, Eindhoven University
of Technology, 5600 MBEindhoven, The Netherlands,Institute
for Complex Molecular Systems (ICMS), Eindhoven
University of Technology, 5600 MBEindhoven, The Netherlands,Helia
Biomonitoring, De Lismortel
31, 5612 AREindhoven, The Netherlands,
| |
Collapse
|
11
|
Buskermolen AD, Lin YT, van Smeden L, van Haaften RB, Yan J, Sergelen K, de Jong AM, Prins MWJ. Continuous biomarker monitoring with single molecule resolution by measuring free particle motion. Nat Commun 2022; 13:6052. [PMID: 36229441 PMCID: PMC9561105 DOI: 10.1038/s41467-022-33487-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 09/20/2022] [Indexed: 12/24/2022] Open
Abstract
There is a need for sensing technologies that can continuously monitor concentration levels of critical biomolecules in applications such as patient care, fundamental biological research, biotechnology and food industry, as well as the environment. However, it is fundamentally difficult to develop measurement technologies that are not only sensitive and specific, but also allow monitoring over a broad concentration range and over long timespans. Here we describe a continuous biomolecular sensing methodology based on the free diffusion of biofunctionalized particles hovering over a sensor surface. The method records digital events due to single-molecule interactions and enables biomarker monitoring at picomolar to micromolar concentrations without consuming any reagents. We demonstrate the affinity-based sensing methodology for DNA-based sandwich and competition assays, and for an antibody-based cortisol assay. Additionally, the sensor can be dried, facilitating storage over weeks while maintaining its sensitivity. We foresee that this will enable the development of continuous monitoring sensors for applications in fundamental research, for studies on organs on a chip, for the monitoring of patients in critical care, and for the monitoring of industrial processes and bioreactors as well as ecological systems.
Collapse
Affiliation(s)
- Alissa D. Buskermolen
- grid.6852.90000 0004 0398 8763Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Yu-Ting Lin
- grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Laura van Smeden
- grid.6852.90000 0004 0398 8763Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Rik B. van Haaften
- grid.6852.90000 0004 0398 8763Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Junhong Yan
- Helia Biomonitoring, Eindhoven, the Netherlands
| | - Khulan Sergelen
- grid.6852.90000 0004 0398 8763Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Arthur M. de Jong
- grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Menno W. J. Prins
- grid.6852.90000 0004 0398 8763Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, the Netherlands ,grid.6852.90000 0004 0398 8763Department of Applied Physics, Eindhoven University of Technology, Eindhoven, the Netherlands ,Helia Biomonitoring, Eindhoven, the Netherlands
| |
Collapse
|
12
|
Xie L, Chen T, Dong X, Liu G, Wang H, Xiao X. High switching ratio and inorganic gas sensing performance in BeN 4based nanodevice: a first-principles study. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2022; 34:465302. [PMID: 36108620 DOI: 10.1088/1361-648x/ac9269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 09/15/2022] [Indexed: 06/15/2023]
Abstract
Recently, Dirac material BeN4has been synthesized by using laser-heated diamond anvil-groove technology (Bykovet al2021Phys. Rev. Lett.126175501). BeN4layer, i.e. beryllonitrene, represents a qualitatively class of two-dimensional (2D) materials that can be built of a metal atom and polymeric nitrogen chains, and hosts anisotropic Dirac fermions. Enlighten by this discovered material, we study the electronic structure, anisotropic transport properties and gas sensitivity of 2D BeN4using the density functional theory combined with non-equilibrium Green's function method. The results manifest that the 2D BeN4shows a typical semi-metallic property. The electronic transport properties of the intrinsic BeN4devices show a strong anisotropic behavior since electrons transmitting along the armchair direction is much easier than that along the zigzag direction. It directly results in an obvious switching characteristic with the switching ratio up to 105. Then the adsorption characteristics indicate that H2S, CO, CO2and H2molecules are physisorption, while the NH3, NO, NO2, SO2molecules are chemisorption. Among these chemisorption cases, the 2D gas sensor devices show an extremely high response for SO2recognition, and the high anisotropy of the original 2D BeN4device still maintains after adsorbing gas molecules. Finally, high switching ratio and inorganic gas sensing performance of BeN4monolayer could be clearly understood with local density of states, bias-dependent spectra, scattered state distribution. In general, the results indicate that the designed BeN4devices have potential practical application in high-ratio switching devices and high gas-sensing molecular devices.
Collapse
Affiliation(s)
- Luzhen Xie
- School of Energy and Mechanical Engineering, Energy Materials Computing Center, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Tong Chen
- School of Energy and Mechanical Engineering, Energy Materials Computing Center, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
- State Key Laboratory of Surface Physics and Department of Physics, Fudan University, Shanghai 200433, People's Republic of China
| | - Xiansheng Dong
- School of Energy and Mechanical Engineering, Energy Materials Computing Center, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Guogang Liu
- School of Energy and Mechanical Engineering, Energy Materials Computing Center, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Haipeng Wang
- School of Energy and Mechanical Engineering, Energy Materials Computing Center, Jiangxi University of Science and Technology, Nanchang 330013, People's Republic of China
| | - Xianbo Xiao
- School of Computer Science, Jiangxi University of Chinese Medicine, Nanchang 330004, People's Republic of China
| |
Collapse
|
13
|
Lubken RM, de Jong AM, Prins MWJ. Real-Time Monitoring of Biomolecules: Dynamic Response Limits of Affinity-Based Sensors. ACS Sens 2022; 7:286-295. [PMID: 34978190 PMCID: PMC8805115 DOI: 10.1021/acssensors.1c02307] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
![]()
Sensors for monitoring
biomolecular dynamics in biological systems
and biotechnological processes in real time, need to accurately and
precisely reconstruct concentration–time profiles. This requirement
becomes challenging when transport processes and biochemical kinetics
are important, as is typically the case for biomarkers at low concentrations.
Here, we present a comprehensive methodology to study the concentration–time
profiles generated by affinity-based sensors that continuously interact
with a biological system of interest. Simulations are performed for
sensors with diffusion-based sampling (e.g., a sensor
patch on the skin) and advection-based sampling (e.g., a sensor connected to a catheter). The simulations clarify how
transport processes and molecular binding kinetics result in concentration
gradients and time delays in the sensor system. Using these simulations,
measured and true concentration–time profiles of insulin were
compared as a function of sensor design parameters. The results lead
to guidelines on how biomolecular monitoring sensors can be designed
for optimal bioanalytical performance in terms of concentration and
time properties.
Collapse
Affiliation(s)
- Rafiq M. Lubken
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
| | - Arthur M. de Jong
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
| | - Menno W. J. Prins
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, the Netherlands
- Helia Biomonitoring, Eindhoven 5612 AZ, the Netherlands
| |
Collapse
|