1
|
Li H, Cai Q, Li Z, Jie G, Zhou H. A spatial-potential resolved bipolar electrode electrochemiluminescence biosensor based on polarity conversion for dual-mode detection of miRNA-122 and CEA. Biosens Bioelectron 2024; 255:116258. [PMID: 38555769 DOI: 10.1016/j.bios.2024.116258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/21/2024] [Accepted: 03/27/2024] [Indexed: 04/02/2024]
Abstract
In this work, a spatial-potential resolved bipolar electrode electrochemiluminescence (BPE-ECL) biosensor based on polarity conversion strategy and CuHCF electrocatalyst was constructed for dual-mode detection of miRNA-122 and carcinoembryonic antigen (CEA). ECL technology was firstly used to systematically study the polarity conversion of BPE. It was found that changing the polarity of the driving voltage would cause the polarity change of BPE, and led to the change of the luminescent position of Ru(bpy)32+. As a "proof-of-concept application", we developed a shielded dual-channel BPE-ECL biosensor for dual-mode detection of miRNA-122 and CEA. In order to further improve the detection sensitivity, a non-precious metal electrocatalyst CuHCF with outstanding electrocatalytic reduction activity of H2O2 was firstly introduced to the BPE-ECL biosensor for signal amplification, which could generate high faradaic current under the excitation of negative potential. Based on the charge neutrality principle of BPE, the enhancement of the faradaic current resulted in the ECL signal amplification of Ru(bpy)32+. The targets in the sensing grooves caused the introduction or fall off of CuHCF, which led to the ECL signal change of Ru(bpy)32+ in the signal grooves, and realized the dual-mode detection of miRNA-122 and CEA. This work provided a deeper understanding of the polarity change of BPE. Furthermore, the introduction of non-precious metal electrocatalyst had broadened the application range of BPE-ECL sensors.
Collapse
Affiliation(s)
- Hongkun Li
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Qianqian Cai
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Zhikang Li
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Guifen Jie
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Hong Zhou
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering. Qingdao University of Science and Technology, Qingdao, 266042, PR China
| |
Collapse
|
2
|
Probst D, Sode K. Development of closed bipolar electrode based L-lactate sensor employing quasi-direct electron transfer type enzyme with cyclic voltammetry. Biosens Bioelectron 2024; 254:116197. [PMID: 38493528 DOI: 10.1016/j.bios.2024.116197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/22/2024] [Accepted: 03/06/2024] [Indexed: 03/19/2024]
Abstract
Herein, we present a proof-of-concept of an enzyme sensor combining closed bipolar electrode system with quasi-direct electron transfer (DET) type enzyme. The closed bipolar electrode system was tested using cyclic voltammetry, with L-lactate as a model substrate. L-Lactate was detected through measurement of the change in junction potential across the bipolar electrode. This change in junction potential was caused by reduction of amino reactive phenazine ethosulfate conjugated to Aerococcus vilidans derived engineered L-lactate oxidase (AvLOx) which shows a quasi-DET signal. Using the closed bipolar electrode system allowed simultaneous measuring using cyclic voltammetry and open circuit potential (OCP) and achieved a limit of detection of 400 μM and 76.2 μM lactate respectively. The sensor was then demonstrated to perform with equivalent sensitivity using OCP across varying surface areas. To the best of our knowledge this is the first time a closed bipolar electrode system has been used with an enzyme which is capable of quasi-direct or direct electron transfer. This work can be expanded further to other enzymes capable of directly altering the junction potential of an electrode surface.
Collapse
Affiliation(s)
- David Probst
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA
| | - Koji Sode
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA.
| |
Collapse
|
3
|
Damirchi Z, Firoozbakhtian A, Hosseini M, Ganjali MR. Ti 3C 2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry. Mikrochim Acta 2024; 191:137. [PMID: 38358570 DOI: 10.1007/s00604-024-06209-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 01/10/2024] [Indexed: 02/16/2024]
Abstract
An innovative electrochemical sensor is introduced that utilizes bipolar electrochemistry on a paper substrate for detecting glucose in sweat. The sensor employs a three-dimensional porous nanocomposite (MXene/NiSm-LDH) formed by decorating nickel-samarium nanoparticles with double-layer MXene hydroxide. These specially designed electrodes exhibit exceptional electrocatalytic activity during glucose oxidation. The glucose sensing mechanism involves enzyme-free oxidation of the analyte within the sensor cell, achieved by applying an appropriate potential. This leads to the reduction of K3Fe(CN)6 in the reporter cell, and the resulting current serves as the response signal. By optimizing various parameters, the measurement platform enables the accurate determination of sweat glucose concentrations within a linear range of 10 to 200 µM. The limit of detection (LOD) for glucose is 3.6 µM (S/N = 3), indicating a sensitive and reliable detection capability. Real samples were analysed to validate the sensor's efficiency, and the results obtained were both promising and encouraging.
Collapse
Affiliation(s)
- Zahra Damirchi
- Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1439817435, Iran
| | - Ali Firoozbakhtian
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, 1439817435, Iran
| | - Morteza Hosseini
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, 1439817435, Iran.
- Medical Genetics Department, Institute of Medical Biotechnology (IMB), National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran.
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1439817435, Iran.
| |
Collapse
|
4
|
Du Y, Reitemeier J, Jiang Q, Bappy MO, Bohn PW, Zhang Y. Hybrid Printing of Fully Integrated Microfluidic Devices for Biosensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2304966. [PMID: 37752777 DOI: 10.1002/smll.202304966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 08/22/2023] [Indexed: 09/28/2023]
Abstract
The advent of 3D printing has facilitated the rapid fabrication of microfluidic devices that are accessible and cost-effective. However, it remains a challenge to fabricate sophisticated microfluidic devices with integrated structural and functional components due to limited material options of existing printing methods and their stringent requirement on feedstock material properties. Here, a multi-materials multi-scale hybrid printing method that enables seamless integration of a broad range of structural and functional materials into complex devices is reported. A fully printed and assembly-free microfluidic biosensor with embedded fluidic channels and functionalized electrodes at sub-100 µm spatial resolution for the amperometric sensing of lactate in sweat is demonstrated. The sensors present a sensitive response with a limit of detection of 442 nm and a linear dynamic range of 1-10 mm, which are performance characteristics relevant to physiological levels of lactate in sweat. The versatile hybrid printing method offers a new pathway toward facile fabrication of next-generation integrated devices for broad applications in point-of-care health monitoring and sensing.
Collapse
Affiliation(s)
- Yipu Du
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Julius Reitemeier
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Qiang Jiang
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Md Omarsany Bappy
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Paul W Bohn
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Yanliang Zhang
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| |
Collapse
|
5
|
Ranjbar S, Salavati AH, Ashari Astani N, Naseri N, Davar N, Ejtehadi MR. Electrochromic Sensor Augmented with Machine Learning for Enzyme-Free Analysis of Antioxidants. ACS Sens 2023; 8:4281-4292. [PMID: 37963856 DOI: 10.1021/acssensors.3c01637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2023]
Abstract
Our study presents an electrochromic sensor that operates without the need for enzymes or multiple oxidant reagents. This sensor is augmented with machine learning algorithms, enabling the identification, classification, and prediction of six different antioxidants with high accuracy. We utilized polyaniline (PANI), Prussian blue (PB), and copper-Prussian blue analogues (Cu-PBA) at their respective oxidation states as electrochromic materials (ECMs). By designing three readout channels with these materials, we were able to achieve visual detection of antioxidants without relying on traditional "lock and key" specific interactions. Our sensing approach is based on the direct electrochemical reactions between oxidized electrochromic materials (ECMsox) as electron acceptors and various antioxidants, which act as electron donors. This interaction generates unique fingerprint patterns by switching the ECMsox to reduced electrochromic materials (ECMsred), causing their colors to change. Through the application of density functional theory (DFT), we demonstrated the molecular-level basis for the distinct multicolor patterns. Additionally, machine learning algorithms were employed to correlate the optical patterns with RGB data, enabling complex data analysis and the prediction of unknown samples. To demonstrate the practical applications of our design, we successfully used the EC sensor to diagnose antioxidants in serum samples, indicating its potential for the on-site monitoring of antioxidant-related diseases. This advancement holds promise for various applications, including the real-time monitoring of antioxidant levels in biological samples, the early diagnosis of antioxidant-related diseases, and personalized medicine. Furthermore, the success of our electrochromic sensor design highlights the potential for exploring similar strategies in the development of sensors for diverse analytes, showcasing the versatility and adaptability of this approach.
Collapse
Affiliation(s)
- Saba Ranjbar
- Department of Physics, Sharif University of Technology, Tehran 11365-9161, Iran
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 14965/161, Iran
| | - Amir Hesam Salavati
- Tehran Institute of Advanced Studies (TeIAS), Khatam University, Tehran 1991633357, Iran
| | - Negar Ashari Astani
- Departments of Physics and Energy Engineering, Amirkabir University of Technology, Tehran 15875-4413, Iran
| | - Naimeh Naseri
- Department of Physics, Sharif University of Technology, Tehran 11365-9161, Iran
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia
- ARC Research Hub for Advanced Manufacturing with Two-dimensional Materials (AM2D), Monash University, Clayton, VIC 3800, Australia
| | - Navid Davar
- Departments of Physics and Energy Engineering, Amirkabir University of Technology, Tehran 15875-4413, Iran
| | | |
Collapse
|
6
|
Mwanza C, Ding SN. Newly Developed Electrochemiluminescence Based on Bipolar Electrochemistry for Multiplex Biosensing Applications: A Consolidated Review. BIOSENSORS 2023; 13:666. [PMID: 37367031 PMCID: PMC10295983 DOI: 10.3390/bios13060666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/28/2023]
Abstract
Recently, there has been an upsurge in the extent to which electrochemiluminescence (ECL) working in synergy with bipolar electrochemistry (BPE) is being applied in simple biosensing devices, especially in a clinical setup. The key objective of this particular write-up is to present a consolidated review of ECL-BPE, providing a three-dimensional perspective incorporating its strengths, weaknesses, limitations, and potential applications as a biosensing technique. The review encapsulates critical insights into the latest and novel developments in the field of ECL-BPE, including innovative electrode designs and newly developed, novel luminophores and co-reactants employed in ECL-BPE systems, along with challenges, such as optimization of the interelectrode distance, electrode miniaturization and electrode surface modification for enhancing sensitivity and selectivity. Moreover, this consolidated review will provide an overview of the latest, novel applications and advances made in this field with a bias toward multiplex biosensing based on the past five years of research. The studies reviewed herein, indicate that the technology is rapidly advancing at an outstanding purse and has an immense potential to revolutionize the general field of biosensing. This perspective aims to stimulate innovative ideas and inspire researchers alike to incorporate some elements of ECL-BPE into their studies, thereby steering this field into previously unexplored domains that may lead to unexpected, interesting discoveries. For instance, the application of ECL-BPE in other challenging and complex sample matrices such as hair for bioanalytical purposes is currently an unexplored area. Of great significance, a substantial fraction of the content in this review article is based on content from research articles published between the years 2018 and 2023.
Collapse
Affiliation(s)
- Christopher Mwanza
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
- Chemistry Department, University of Zambia, Lusaka 10101, Zambia
| | - Shou-Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|