1
|
Wei W, Wu J, Hassan MM, Jiao T, Xu Y, Ding Z, Li H, Chen Q. Generalized ratiometric surface-enhanced Raman scattering biosensor for okadaic acid in food based on Au-triggered signal amplification. Anal Chim Acta 2024; 1310:342705. [PMID: 38811142 DOI: 10.1016/j.aca.2024.342705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 04/25/2024] [Accepted: 05/08/2024] [Indexed: 05/31/2024]
Abstract
BACKGROUND Reliability and robustness have been recognized as key challenges for Surface-enhanced Raman scattering (SERS) analytical techniques. Quantifying the concentration of an analyte using a single characteristic peak from SERS has been a controversial topic because the Raman signal is susceptible to highly concentrated electromagnetic hotspots, inhomogeneity of SERS substrate, or non-standardization of measurement conditions. Ratiometric SERS strategies have been demonstrated as a promising solution to effectively balance and compensate for signal fluctuations caused by matrix heterogeneity. However, it is not easy to construct ratiometric SERS sensors with monitoring the ratio of two different signal intensities for target analysis. RESULTS An attempt has been made to develop a novel ratiometric biosensor that can be applied to detect okadaic acid (OA). Aptamer-anchored magnetic particles were first combined with gold-tagged short complementary DNA (Au-cDNA) to create heterogeneous nanostructures. When the target was present, the Au-cDNA was dissociated from nanostructures, and 4-nitrothiophenol (4-NTP) was initiated to reduce to 4-aminothiophenol (4-ATP) in the presence of hydrogen sources. The SERS ratio change of 4-NTP and 4-ATP was finally detected by AuNPs-coated film. OA was successfully quantified, and the detection limit was as low as 2.4524 ng/mL. The constructed biosensor had good stability and reproducibility with a relative standard deviation of less than 4.47%. The proposed method used gold nanoparticles as an intermediate to achieve catalytic signal amplification and subsequently increased the sensitivity of the biosensor. SIGNIFICANCE AND NOVELTY Catalytic reaction-based ratiometric SERS biosensors combine the multiple advantages of catalytic signal amplification and signal self-calibration and provide new insights into the development of stable, reproducible, and reliable SERS detection techniques. This ratiometric SERS technique offered a universal method that is anticipated to be applicable for the detection of other targets by substituting the aptamer.
Collapse
Affiliation(s)
- Wenya Wei
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, 212013, PR China
| | - Jizhong Wu
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, 212013, PR China
| | - Md Mehedi Hassan
- College of Food and Biological Engineering, Jimei University, Xiamen, 361021, PR China
| | - Tianhui Jiao
- College of Food and Biological Engineering, Jimei University, Xiamen, 361021, PR China
| | - Yi Xu
- College of Food and Biological Engineering, Jimei University, Xiamen, 361021, PR China
| | - Zhen Ding
- Changzhou Jintan Jiangnan Powder Co. LTD, Changzhou, 213200, PR China
| | - Huanhuan Li
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, 212013, PR China.
| | - Quansheng Chen
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, 212013, PR China; College of Food and Biological Engineering, Jimei University, Xiamen, 361021, PR China.
| |
Collapse
|
2
|
Shen K, Bi C, Yang H, Xu M, Huang L, Wang Y. Phenylboronic acid modification-based novel dumbbell-shaped Au-Ag nanorod SERS substrates for ultrasensitive detection of SO 42. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2311-2321. [PMID: 38529920 DOI: 10.1039/d3ay01831h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
Based on the coordination principle of Lewis acids, a 4-mercaptophenylboronic acid (4-MPBA)-modified novel dumbbell-shaped Au-Ag nanorod (4-MPBA@DS Au-AgNR) substrate was developed, which could be combined with the surface-enhanced Raman scattering (SERS) technique to detect SO42- with high sensitivity and specificity. DS Au-AgNRs synthesized in this study with a dumbbell-shaped structure were verified by finite-difference time domain (FDTD) simulation to be capable of stimulating strong localized electromagnetic enhancement (EM) at nano-edge and gap, generating a large number of "hot spots" exhibiting excellent SERS performance. The 4-MPBA modified on its surface could specifically recognize SO42-, producing a change in the spectral peak at 1382 cm-1, thus realizing highly sensitive and specific sensing of SO42-. Under optimized conditions, this SERS sensor responded rapidly to SO42- within 2 minutes and demonstrated outstanding specificity. Calculation of the ratio of the characteristic peaks at 1382 and 1070 cm-1 (I1382/I1070) enabled the quantitative detection of SO42- in the range of 1 × 10-8-1 × 10-3 M, and the detection threshold was as low as 1 nM, which was superior to those of similar detection methods. Importantly, the utility and reliability of this SERS substrate for the determination of SO42- in actual samples were evaluated using ion chromatography as the gold standard, and there was no significant difference between the two protocols (P > 0.05), and the RSD was less than 6% with a satisfactory recovery rate (97.6-102.3%). Therefore, the present protocol has the advantages of simplicity and rapidity, high sensitivity, specificity, stability, and practicability in the determination of SO42- in aqueous solution, providing a reliable solution for tracing SO42- in the fields of food safety and environmental testing.
Collapse
Affiliation(s)
- Kang Shen
- Department of Neurosurgery, The Affiliated Hospital of Yangzhou University, Yangzhou 225001, PR China.
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou 225001, PR China
| | - Caili Bi
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou 225001, PR China
| | - Haifan Yang
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou 225001, PR China
| | - Miaowen Xu
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou 225001, PR China
| | - Lili Huang
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou 225001, PR China
| | - Youwei Wang
- Department of Neurosurgery, The Affiliated Hospital of Yangzhou University, Yangzhou 225001, PR China.
| |
Collapse
|
3
|
Wei S, Zhao X, Zhao K, Wang M, Xu L, Zhang Y, Huang X, Chen Y. Flexible, foldable and transparent SERS film with high sensitivity and signal homogeneity via silver ion exchange and in-situ reduction. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 306:123624. [PMID: 37948934 DOI: 10.1016/j.saa.2023.123624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 10/27/2023] [Accepted: 11/04/2023] [Indexed: 11/12/2023]
Abstract
The adhesion between metal plasma and substrate was the key of surface-enhanced Raman scattering (SERS) technology. The preparation of ideal SERS substrate with multiple advantages such as high sensitivity and good signal reproducibility was still the focus of research. A flexible foldable and transparent fluorinated polyimide/silver NPs (FPI@Ag) SERS film was fabricated by the ion exchange and in-situ reduction method in this work. The effects of KOH hydrolysis time, AgNO3 ion exchange time and concentration, the type and concentration of reducing agents on the SERS performance of the FPI@Ag film were systematically discussed. As a result, the hydrolysis time of KOH affected the thickness of the metallic silver layer, the concentration of AgNO3 affected the size and spacing of Ag NPs, and the Raman signal of was remarkably enhanced when borane dimethylamine complex (DMAB) was used as reducing agent. When the detection limit of 4-Aminothiophenol was as low as 1 × 10-11 mol·L-1, the obvious Raman characteristic peak still appeared. The enhancement factor (EF) was up to 9.4 × 107. The linear quantification range was achieved in the range from 10-3-10-11 mol·L-1, R2 = 0.9987. In addition, we also performed multi-cycle bending and torsion test on the FPI@Ag film, and obtained stable Raman signals. The prepared FPI@Ag film can be attached to the surface of uneven samples, which can be used for on-site Raman detection and analysis.
Collapse
Affiliation(s)
- Siyu Wei
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - Xinyu Zhao
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - Ke Zhao
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - Meng Wang
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - LinZhe Xu
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - Yuanyuan Zhang
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - Xiujing Huang
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China
| | - Yingbo Chen
- School of Materials Science and Engineering, State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin 300387, PR China.
| |
Collapse
|
4
|
Xu Y, Zhang X, Zhu XS, Shi YW. Surface-Enhanced Raman Scattering in Silver-Coated Suspended-Core Fiber. SENSORS (BASEL, SWITZERLAND) 2023; 24:160. [PMID: 38203021 PMCID: PMC10781242 DOI: 10.3390/s24010160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/20/2023] [Accepted: 12/25/2023] [Indexed: 01/12/2024]
Abstract
In this paper, the silver-coated large-core suspended-core fiber (LSCF) probe was fabricated by the dynamic chemical liquid phase deposition method for surface-enhanced Raman scattering (SERS) sensing. The 4-mercaptophenylboronic acid (4-MPBA) monolayer was assembled in the LSCF as the recognition monolayer. Taking advantage of the appropriate core size of the LSCF, a custom-made Y-type optical fiber patch cable was utilized to connect the semiconductor laser, Raman spectrometer, and the proposed fiber SERS probe. The SERS signal is propagated in the silver-coated air channels, which can effectively reduce the Raman and fluorescence background of the silica core. Experiments were performed to measure the Raman scattering spectra of the 4-MPBA in the silver-coated LSCF in a non-enhanced and enhanced case. The experiment results showed that the Raman signal strength was enhanced more than 6 times by the surface plasmon resonance compared with the non-enhanced case. The proposed LSCF for SERS sensing technology provides huge research value for the fiber SERS probes in biomedicine and environmental science. The combination of SERS and microstructured optical fibers offers a potential approach for SERS detection.
Collapse
Affiliation(s)
- Yangyang Xu
- School of Information Science and Engineering, Fudan University, 220 Handan Rd, Shanghai 200433, China; (Y.X.); (X.Z.); (Y.-W.S.)
- Yiwu Research Institute of Fudan University, Chengbei Road, Yiwu City 322000, China
| | - Xian Zhang
- School of Information Science and Engineering, Fudan University, 220 Handan Rd, Shanghai 200433, China; (Y.X.); (X.Z.); (Y.-W.S.)
- Yiwu Research Institute of Fudan University, Chengbei Road, Yiwu City 322000, China
| | - Xiao-Song Zhu
- School of Information Science and Engineering, Fudan University, 220 Handan Rd, Shanghai 200433, China; (Y.X.); (X.Z.); (Y.-W.S.)
- Yiwu Research Institute of Fudan University, Chengbei Road, Yiwu City 322000, China
- Key Laboratory for Information Science of Electromagnetic Waves (MoE), Fudan University, 220 Handan Rd, Shanghai 200433, China
| | - Yi-Wei Shi
- School of Information Science and Engineering, Fudan University, 220 Handan Rd, Shanghai 200433, China; (Y.X.); (X.Z.); (Y.-W.S.)
- Key Laboratory for Information Science of Electromagnetic Waves (MoE), Fudan University, 220 Handan Rd, Shanghai 200433, China
| |
Collapse
|
5
|
Barbillon G, Cheap-Charpentier H. Advances in Surface-Enhanced Raman Scattering Sensors of Pollutants in Water Treatment. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2417. [PMID: 37686925 PMCID: PMC10489740 DOI: 10.3390/nano13172417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/10/2023]
Abstract
Water scarcity is a world issue, and a solution to address it is the use of treated wastewater. Indeed, in these wastewaters, pollutants such as pharmaceuticals, pesticides, herbicides, and heavy ions can be present at high concentrations. Thus, several analytical techniques were initiated throughout recent years for the detection and quantification of pollutants in different types of water. Among them, the surface-enhanced Raman scattering (SERS) technique was examined due to its high sensitivity and its ability to provide details on the molecular structure. Herein, we summarize the most recent advances (2021-2023) on SERS sensors of pollutants in water treatment. In this context, we present the results obtained with the SERS sensors in terms of detection limits serving as assessment of SERS performances of these sensors for the detection of various pollutants.
Collapse
Affiliation(s)
- Grégory Barbillon
- EPF-Ecole d’Ingénieurs, 55 Avenue du Président Wilson, 94230 Cachan, France;
| | - Hélène Cheap-Charpentier
- EPF-Ecole d’Ingénieurs, 55 Avenue du Président Wilson, 94230 Cachan, France;
- Laboratoire Interfaces et Systèmes Electrochimiques, Sorbonne Université, CNRS, UMR 8235, LISE, 4 Place Jussieu, 75005 Paris, France
| |
Collapse
|
6
|
Sha H, Yan B. Terbium-based metal-organic frameworks through energy transfer modulation for visual logical sensing zinc and fluorine ions. Talanta 2023; 257:124326. [PMID: 36801562 DOI: 10.1016/j.talanta.2023.124326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 02/01/2023] [Accepted: 02/02/2023] [Indexed: 02/16/2023]
Abstract
Zinc is the second most abundant trace element in the human central nervous system, which is closely related to various physiological activities in the human body. Fluoride ion is one of the most harmful elements in drinking water. Excessive intake of F- may cause dental fluorosis, renal failure, or DNA damage. Therefore, it is urgent to develop sensors with high sensitivity and selectivity for the detection of Zn2+ and F- ions at the same time. In this work, a series of mixed lanthanide metal-organic frameworks (Ln-MOFs) probes are synthesized using a simple method of in situ doping. The luminous color can be finely modulated by changing the molar ratio of Tb3+ and Eu3+ during synthesis. Benefiting from the unique energy transfer modulation mechanism, the probe has the continuous detection capability of zinc ions and fluoride ions. The detection of Zn2+ and F- in a real environment shows that the probe has a good practical application prospect. The as-designed sensor at 262 nm excitation can sequentially detect Zn2+ concentrations ranging from 10-8 to 10-3 M (LOD = 4.2 nM) and F- levels ranging from 10-5 to 10-3 M (LOD = 3.6 μM) with high selectivity. Based on different output signals, a simple Boolean logic gate device is constructed to realize intelligent visualization of Zn2+ and F- monitoring.
Collapse
Affiliation(s)
- Haifeng Sha
- School of Chemical Science and Engineering, Tongji University, Siping Road 1239, Shanghai, 200092, China
| | - Bing Yan
- School of Chemical Science and Engineering, Tongji University, Siping Road 1239, Shanghai, 200092, China.
| |
Collapse
|
7
|
Kitaw SL, Birhan YS, Tsai HC. Plasmonic surface-enhanced Raman scattering nano-substrates for detection of anionic environmental contaminants: Current progress and future perspectives. ENVIRONMENTAL RESEARCH 2023; 221:115247. [PMID: 36640935 DOI: 10.1016/j.envres.2023.115247] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/26/2022] [Accepted: 01/06/2023] [Indexed: 06/17/2023]
Abstract
Surface-enhanced Raman scattering spectroscopy (SERS) is a powerful technique of vibrational spectroscopy based on the inelastic scattering of incident photons by molecular species. It has unique properties such as ultra-sensitivity, selectivity, non-destructivity, speed, and fingerprinting properties for analytical and sensing applications. This enables SERS to be widely used in real-world sample analysis and basic plasmonic mechanistic studies. However, the desirable properties of SERS are compromised by the high cost and low reproducibility of the signals. The development of multifunctional, stable and reusable nano-engineered SERS substrates is a viable solution to circumvent these drawbacks. Recently, plasmonic SERS active nano-substrates with various morphologies have attracted the attention of researchers due to promising properties such as the formation of dense hot spots, additional stability, tunable and controlled morphology, and surface functionalization. This comprehensive review focused on the current advances in the field of SERS active nanosubstrates suitable for the detection and quantification of anionic environmental pollutants. The common fabrication methods, including the techniques for morphological adjustments and surface modification, substrate categories, and the design of nanotechnologically fabricated plasmonic SERS substrates for anion detection are systematically presented. Here, the need for the design, synthesis, and functionalization of SERS nano-substrates for anions of great environmental importance is explained in detail. In addition, the broad categories of SERS nano-substrates, namely colloid-based SERS substrates and solid-support SERS substrates are discussed. Moreover, a brief discussion of SERS detection of certain anionic pollutants in the environment is presented. Finally, the prospects in the fabrication and commercialization of pilot-scale handheld SERS sensors and the construction of smart nanosubstrates integrated with novel amplifying materials for the detection of anions of environmental and health concern are proposed.
Collapse
Affiliation(s)
- Sintayehu Leshe Kitaw
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC
| | - Yihenew Simegniew Birhan
- Department of Chemistry, College of Natural and Computational Sciences, Debre Markos University, P.O. Box 269, Debre Markos, Ethiopia
| | - Hsieh-Chih Tsai
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC; Advanced Membrane Materials Center, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC; R&D Center for Membrane Technology, Chung Yuan Christian University, Chungli, Taoyuan, 320, Taiwan, ROC.
| |
Collapse
|
8
|
Liu J, Zhan Y, Qiu B, Lin Z, Guo L. Portable Smartphone Platform Based on Aggregation-Induced Enhanced Emission Carbon Dots for Ratiometric Quantitative Sensing of Fluoride Ions. ACS Sens 2023; 8:884-892. [PMID: 36657970 DOI: 10.1021/acssensors.2c02589] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
The development of an instrument-free, on-site, real-time, sensitive, and visualized fluoride-ion (F-) content rapid detection strategy is crucial to ensuring the health of the population. Smart microdevices that are portable, directly read, and easy to operate have recently attracted much attention. Herein, a ratiometric fluorescent probe (AA-CDs@[Ru(bpy)3]2+)-based smartphone sensing platform was developed for the detection of F-. The red fluorescent ruthenium bipyridine [Ru(bpy)3]2+ molecule was chosen as the reference signal, and the carbon dots (AA-CDs) with Al3+ aggregation-induced enhanced emission (AIE) were designed as the response signal. The ratiometric probe fluorescence changed continuously from red to cyan in response to different concentrations of F-, and the red-green-blue (RGB) channel values of the fluorescence image were extracted through the smartphone color recognition application (APP). There was a linear relationship between the blue-red (B/R) ratio and the F- concentration, with a limit of detection (LOD) of 1.53 μM, far below the allowable content of F- in drinking water prescribed by the World Health Organization. The F- content was rapidly detected on-site with satisfactory repeatability and relative standard deviation using several water and toothpaste samples as the real sample. The platform features low cost, portability, easy operation, and good stability, selectivity, and repeatability, which provides a powerful tool for the visual quantitative detection of smartphone-based microsensing platforms possibly in the fields of environmental protection, diagnosis, and food safety assessment.
Collapse
Affiliation(s)
- Jingjing Liu
- Fujian Universities and Colleges Engineering Research Center of Soft Plastic Packaging Technology for Food, Fujian Polytechnic Normal University, Fuqing, Fujian Province 350300, P. R. China
| | - Yuanjin Zhan
- Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers and Chem, Fudan University, Shanghai 200433, P. R. China
| | - Bin Qiu
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, College of Chemistry, Fuzhou University, Fuzhou 350116, PR China
| | - Zhenyu Lin
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, College of Chemistry, Fuzhou University, Fuzhou 350116, PR China
| | - Longhua Guo
- MOE Key Laboratory for Analytical Science of Food Safety and Biology, College of Chemistry, Fuzhou University, Fuzhou 350116, PR China.,Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, PR China
| |
Collapse
|
9
|
Novak LM, Steyskal EM. Electrochemical detection of fluoride ions in water with nanoporous gold modified by a boronic acid terminated self-assembled monolayer. RSC Adv 2023; 13:6947-6953. [PMID: 36865575 PMCID: PMC9973417 DOI: 10.1039/d2ra07688h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 02/17/2023] [Indexed: 03/04/2023] Open
Abstract
Nanoporous gold (npAu) is a perfectly suited platform for the electrochemical detection of minor amounts of chemical species in solution due to its high surface-to-volume ratio. By surface-modification of the self-standing structure with a self-assembled monolayer (SAM) of 4-mercaptophenylboronic acid (MPBA) it was possible to create an electrode very sensitive towards fluoride ions in water, also suitable for mobile use in future sensing applications. The proposed detection strategy is based on the change in the charge state of the boronic acid functional groups of the monolayer, induced by fluoride binding. The surface potential of the modified npAu sample reacts fast and sensitively to stepwise F- addition, showing highly reproducible, well-defined potential steps with a detection limit of 0.2 mM. Deeper insight into the reaction of fluoride binding on the MPBA modified surface was gained by electrochemical impedance spectroscopy. The proposed fluoride sensitive electrode exhibits a favorable regenerability in alkaline media, which is of central importance for future applications considering environmental as well as economical aspects.
Collapse
Affiliation(s)
- Lara Marie Novak
- Institute of Material Physics, Graz University of Technology, NAWI Graz Petersgasse 16 8010 Graz Austria
| | - Eva-Maria Steyskal
- Institute of Material Physics, Graz University of Technology, NAWI Graz Petersgasse 16 8010 Graz Austria
| |
Collapse
|
10
|
Li J, Chen J, Dai Y, Liu Z, Zhao J, Liu S, Xiao R. Magnetic SERS Strip Based on 4-mercaptophenylboronic Acid-Modified Fe 3O 4@Au for Active Capture and Simultaneous Detection of Respiratory Bacteria. BIOSENSORS 2023; 13:210. [PMID: 36831976 PMCID: PMC9953780 DOI: 10.3390/bios13020210] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/16/2023] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
The rapid diagnosis and detection of respiratory bacteria at the early stage can effectively control the epidemic spread and bacterial infection. Here, we designed a rapid, ultrasensitive, and quantitative lateral flow immunoassay (LFA) strip for simultaneous detection of respiratory bacteria S. aureus and S. pneumoniae. In this assay, the surface enhanced Raman scattering (SERS) tags were designed through combining magnetite Raman enhancement nanoparticle Fe3O4@Au/DTNB and recognition element 4-mercaptophenylboronic acid (4-MPBA). Further, 4-MPBA could capture multiple bacteria in a complex environmental solution. Based on the strategies, Fe3O4@Au/DTNB-mediated magnetic enrichment and 4-MPBA-mediated universal capture capabilities improved the detection sensitivity, the limits of detection for S. aureus and S. pneumoniae were as low as 8 and 13 CFU mL-1, respectively, which were more sensitive than those of colloidal gold method. The Fe3O4@Au/DTNB/Au/4-MPBA-LFA also exhibited good reproducibility, excellent specificity, and high recovery rates in sputum samples, indicating its potential application in the detection of respiratory bacteria samples.
Collapse
Affiliation(s)
- Jingfei Li
- Beijing Institute of Microbiology and Epidemiology, Beijing 100071, China
| | - Jin Chen
- Beijing Institute of Microbiology and Epidemiology, Beijing 100071, China
- Department of Clinical Laboratory, Beijing Ditan Hospital, Capital Medical University, Beijing 100015, China
| | - Yuwei Dai
- Beijing Institute of Microbiology and Epidemiology, Beijing 100071, China
| | - Zhenzhen Liu
- Beijing Institute of Microbiology and Epidemiology, Beijing 100071, China
| | - Junnan Zhao
- Beijing Institute of Microbiology and Epidemiology, Beijing 100071, China
| | - Shuchen Liu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Rui Xiao
- Beijing Institute of Microbiology and Epidemiology, Beijing 100071, China
| |
Collapse
|
11
|
Lv X, Li S, Yang Q, Zhang S, Su J, Cheng SB, Lai Y, Chen J, Zhan J. Robust, reliable and quantitative sensing of aqueous arsenic species by Surface-enhanced Raman Spectroscopy: The crucial role of surface silver ions for good analytical practice. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 281:121600. [PMID: 35816865 DOI: 10.1016/j.saa.2022.121600] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 06/25/2022] [Accepted: 07/04/2022] [Indexed: 06/15/2023]
Abstract
Arsenic speciation analysis is important for pollution and health risk assessment. Surface-enhanced Raman Spectroscopy (SERS) is supposed to be a promising detection technology for arsenic species owing to the unique fingerprints. However, further application of SERS is hampered by its poor repeatability. Herein, the role of surface silver ions on colloidal Ag was revealed in SERS analysis of arsenic species. Arsenic species were adsorbed on Ag nanoparticles (Ag NPs) driven by surface silver ions and were simultaneously sensed by the SERS "hot spots" generated from the aggregation of Ag NPs. So, the inconsistent SERS activities of Ag NPs synthesized from different batches can be significantly improved by modifying external silver ions onto Ag NPs (AgNPs@Ag+), Specific binding affinity of surface silver ions to arsenic species generated higher sensitivity (detection limit, 4.0 × 10-11 mol L-1 for arsenite, 8.0 × 10-11 mol L-1 for arsenate), wider linear range, faster response, cleaner spectra background and better reproducibility. Batch-to-batch reproducibility was significantly improved with a variation below 3.1%. The method was also demonstrated with drinking and environmental water with adequate recovery and high interference resistance. Our findings displayed good analytical practice of the surface silver ions derived SERS method and its great potential in the rapid detection of hazardous materials.
Collapse
Affiliation(s)
- Xiaochen Lv
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| | - Shu Li
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| | - Qing Yang
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| | - Shaoying Zhang
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| | - Jie Su
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| | - Shi-Bo Cheng
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| | - Yongchao Lai
- Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250117, China.
| | - Jing Chen
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China.
| | - Jinhua Zhan
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China
| |
Collapse
|
12
|
Hao Y, Dong W, Liu Y, Wen X, Shuang S, Hu Q, Dong C, Gong X. Nitrogen-doped carbon dots coupled with morin-Al 3+: Cleverly design an integrated sensing platform for ratiometric optical dual-mode and smartphone-assisted visual detection of fluoride ion. JOURNAL OF HAZARDOUS MATERIALS 2022; 439:129596. [PMID: 35863221 DOI: 10.1016/j.jhazmat.2022.129596] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 06/18/2022] [Accepted: 07/11/2022] [Indexed: 06/15/2023]
Abstract
Ratiometric fluorescence sensor has high selectivity and good sensitivity; however, its development is limited by intricate design, tedious synthesis, etc. Herein, a facile and effective ratiometric fluorescence sensing platform for fluoride ion (F-) detection was developed by simply combining nitrogen-doped carbon dots (N-CDs) and morin-Al3+ based on inner filter effect (IFE). The competitive binding of F- to Al3+ obviously decreased morin-Al3+ fluorescence and increased N-CDs fluorescence, attributing to the inhibition of IFE between N-CDs and morin-Al3+. The as-constructed ratiometric fluorescence sensing platform can be used for F- detection with a wide linear range (0.5-150 μM) and a low detection limit (55.8 nM). Interestingly, with the introduction of F- into the N-CDs/morin-Al3+ sensing platform, a distinguishable change in fluorescence color from green to blue enabled the N-CDs/morin-Al3+ system to be used as a smartphone-assisted visual sensing platform for F- detection with a detection limit of 2.09 μM. This platform was successfully applied for the onsite monitoring of F- in various water samples with satisfying results. These findings provide a novel guidance for the facile construction of a ratiometric optical dual-mode and smartphone-assisted sensing platform based on CDs, revealing the broad application prospect of CDs in environmental monitoring field.
Collapse
Affiliation(s)
- Yumin Hao
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, PR China
| | - Wenjuan Dong
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, PR China
| | - Yang Liu
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, PR China
| | - Xiaole Wen
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, PR China
| | - Shaomin Shuang
- School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006, PR China
| | - Qin Hu
- College of Food Chemistry and Engineering, Yangzhou University, Yangzhou 225001, PR China
| | - Chuan Dong
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, PR China.
| | - Xiaojuan Gong
- Institute of Environmental Science, Shanxi University, Taiyuan 030006, PR China.
| |
Collapse
|
13
|
Highly sensitive sensing and quantitative detection of sulfate ion with a SERS chip-based on boric acid's Lewis effect. ANAL SCI 2022; 38:1385-1394. [PMID: 35927550 DOI: 10.1007/s44211-022-00169-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 07/23/2022] [Indexed: 11/01/2022]
Abstract
Based on the Lewis acid's coordination principle, a surface-enhanced Raman scattering (SERS) chip strategy had been developed for the ultrasensitive quantitation of SO42-. Through the immobilization of silver nanoparticles (Ag NPs) and the construction of the boric acid-based sensing unit, the chip system displayed outstanding merits on the direct sensing of SO42-, e.g., simple operation, ultra-high sensitivity, reproducibility, excellent selectivity and specificity. Moreover, an accurate evaluation was obtained by ratiometric calculations on characteristic peaks (1382 and 1070 cm-1) for quantitative detection of SO42-. The detection limit was down to 10 nM. Tap water, beer, and mineral water samples were tested, and high recoveries were achieved (97.12-110.12%). Besides, such SERS chip also displayed strong applicability for the evaluation of SO32-. Therefore, this SERS chip provided a promising idea for the quantification of trace amounts of SO42- and SO32- in the fields of food safety and environmental monitoring.
Collapse
|
14
|
Raman Spectroscopy for Food Quality Assurance and Safety Monitoring: A Review. Curr Opin Food Sci 2022. [DOI: 10.1016/j.cofs.2022.100910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
15
|
Tang H, Wang H, Zhao D, Cao M, Zhu Y, Li Y. Nanopore-Based Single-Entity Electrochemistry for the Label-Free Monitoring of Single-Molecule Glycoprotein-Boronate Affinity Interaction and Its Sensing Application. Anal Chem 2022; 94:5715-5722. [PMID: 35362966 DOI: 10.1021/acs.analchem.2c00860] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Nanopipettes provide a promising confined space that enables advances in single-molecule analysis, and their unique conical tubular structure is also suitable for single-cell analysis. In this work, functionalized-nanopore-based single-entity electrochemistry (SEE) analysis tools were developed for the label-free monitoring of single-molecule glycoprotein-boronate affinity interaction for the first time, and immunoglobulin G (IgG, one of the important biomarkers for many diseases such as COVID-19 and cancers) was employed as the model glycoprotein. The principle of this method is based on a single glycoprotein molecule passing through 4-mercaptophenylboronic acid (4-MPBA)-modified nanopipettes under a bias voltage and in the meantime interacting with the boronate group from modified 4-MPBA. This translocation and affinity interaction process can generate distinguishable current blockade signals. Based on the statistical analysis of these signals, the equilibrium association constant (κa) of single-molecule glycoprotein-boronate affinity interaction was obtained. The results show that the κa of IgG in the confined nanopore at the single-molecule level is much larger than that measured in the open system at the ensemble level, which is possibly due to the enhanced multivalent synergistic binding in the restricted space. Moreover, the functionalized-nanopore-based SEE analysis tools were further applied for the label-free detection of IgG, and the results indicate that our method has potential application value for the detection of glycoproteins in real samples, which also paves way for the single-cell analysis of glycoproteins.
Collapse
Affiliation(s)
- Haoran Tang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P. R. China
| | - Hao Wang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P. R. China
| | - Dandan Zhao
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P. R. China
| | - Mengya Cao
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P. R. China
| | - Yanyan Zhu
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P. R. China
| | - Yongxin Li
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, P. R. China
| |
Collapse
|
16
|
Chen P, Li C, Ma X, Wang Z, Zhang Y. A surface-enhanced Raman scattering aptasensor for ratiometric detection of aflatoxin B1 based on graphene oxide-Au@Ag core-shell nanoparticles complex. Food Control 2022. [DOI: 10.1016/j.foodcont.2021.108748] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
17
|
Mao Y, Sun Y, Xue J, Lu W, Cao X. Ultra-sensitive and high efficiency detection of multiple non-small cell lung cancer-related miRNAs on a single test line in catalytic hairpin assembly-based SERS-LFA strip. Anal Chim Acta 2021; 1178:338800. [PMID: 34482860 DOI: 10.1016/j.aca.2021.338800] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 06/19/2021] [Accepted: 06/23/2021] [Indexed: 11/29/2022]
Abstract
Accurate quantification of multiple miRNAs biomarkers in body fluid is still a challenge for early screening of cancer. Herein, by catalytic hairpin assembly as a signal amplification strategy, we designed a novel surface-enhanced Raman scattering (SERS)-lateral flow assay (LFA) strip for ultrasensitive detection of miR-21 and miR-196a-5p in non-small cell lung cancer (NSCLC) urine on a single test (T) line. 4-mercaptobenzoic acid or 5,5'-dithiobis-2-nitrobenzoic acid as Raman molecules was labeled and two hairpin DNA sequence was modified gold nanocages (GNCs) were designed as two SERS tags. Through target miRNA-triggered catalytic hairpin assembly (CHA), the double-stranded DNAs (H1-H2 complex) formed by SERS tags and the related hairpin-structured DNA sequence 2 (H2) were immobilized on a single T line of SERS-LFA strip. This generated abundant "hot spots" because of the formation of numerous H1-H2 complex thus facilitated the SERS measurement. Through this method, two kinds of miRNAs were analyzed, resulting in limits of detection of 2.08 pM and 3.31 pM for miR-21 in PBS buffer and human urine, 1.77 pM and 2.18 pM for miR-196a-5p in PBS buffer and human urine. Significantly, the SERS-LFA strip exhibited high specificity and good repeatability toward miRNAs. The whole detection time was only 30 min, which means that the high detection efficiency of the strip. The clinical feasibility of the proposed method was also evaluated by detecting the levels of miR-21 and miR-196a-5p in urine samples from NSCLC patients and healthy subjects. The developed SERS-LFA strip has wide application prospect in biomedical research, drug development and early clinical diagnosis.
Collapse
Affiliation(s)
- Yu Mao
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, 225001, PR China; Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Medical College, Yangzhou University, Yangzhou, 225001, PR China; Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, 225001, PR China
| | - Yue Sun
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, 225001, PR China; Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Medical College, Yangzhou University, Yangzhou, 225001, PR China; Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, 225001, PR China
| | - Jin Xue
- Guangling College, Yangzhou University, Yangzhou, 225001, PR China
| | - Wenbo Lu
- Shanxi Normal University, College of Chemistry and Material Science, Linfen, 041004, PR China
| | - Xiaowei Cao
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, 225001, PR China; Guangling College, Yangzhou University, Yangzhou, 225001, PR China; Jiangsu Key Laboratory of Zoonosis, Yangzhou University, Yangzhou, 225009, PR China; Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Medical College, Yangzhou University, Yangzhou, 225001, PR China; Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, 225001, PR China.
| |
Collapse
|
18
|
Jing M, Zhang H, Li M, Mao Z, Shi X. Silver nanoparticle-decorated TiO 2 nanotube array for solid-phase microextraction and SERS detection of antibiotic residue in milk. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 255:119652. [PMID: 33773431 DOI: 10.1016/j.saa.2021.119652] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 02/21/2021] [Accepted: 03/01/2021] [Indexed: 05/25/2023]
Abstract
The excessive use or abuse of antibiotics on dairy cows leads to residues in milk, which can represent a public health risk. However, in recent years the β-Lactamase was illegally used to degrade residual antibiotics in milk, which makes the traditional antibiotic detection methods ineffective. Therefore, there is an extremely urgent need for multi-analyte analysis techniques for the detection of antibiotic residues. Herein, we reported an ultra-fast, facile, and sensitive solid-phase microextraction (SPME)-surface enhanced Raman scattering (SERS) platform for the detection of degraded antibiotics-2-mercapto-5-methyl-1,3,4-thiadiazole (MMT). The results showed that the log-log plot of SERS intensity to MMT concentration exhibits a superior linear relationship (R2 = 0.992) in the concentration range of 0.5-1000 μM, with a detection limit of 0.11 μM. The silver nanoparticle-decorated TiO2 nanotube array was successfully used as an all-in-one SPME-SERS substrate in the extraction and identification of the antibiotic degradation products in real milk. Due to the rapid pre-treatment, good reproducibility, and self-cleaning, the proposed SPME-SERS method has a great promise to be applied as a powerful tool for on-site detection in the field of food safety.
Collapse
Affiliation(s)
- Mengyu Jing
- School of Chemistry and Life Science, Advanced Institute of Materials Science, Changchun University of Technology, Changchun 130012, China
| | - Hui Zhang
- School of Chemistry and Life Science, Advanced Institute of Materials Science, Changchun University of Technology, Changchun 130012, China
| | - Ming Li
- School of Chemistry and Life Science, Advanced Institute of Materials Science, Changchun University of Technology, Changchun 130012, China
| | - Zhu Mao
- School of Chemistry and Life Science, Advanced Institute of Materials Science, Changchun University of Technology, Changchun 130012, China.
| | - Xiumin Shi
- College of Chemical Engineering, Changchun University of Technology, Changchun 130012, China.
| |
Collapse
|
19
|
Duan J, Qiu Z, Li L, Feng L, Huang L, Xiao G. Inkjet printed silver nanoparticles on hydrophobic papers for efficient detection of thiram. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 243:118811. [PMID: 32829159 DOI: 10.1016/j.saa.2020.118811] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 07/31/2020] [Accepted: 08/05/2020] [Indexed: 05/27/2023]
Abstract
Silver nanoparticles coated paper (AgNPs-paper) substrates were prepared by inkjet printing Ag ink on four different wettability papers. Scanning electron microscope and contact angle analyzer were used to characterize their surface morphology and wettability. AgNPs-paper substrates were used to detect the surface-enhanced Raman scattering (SERS) spectra of thiram aqueous solution. Relationships between the surface wettability, surface morphology and SERS activities of the substrates were systematically studied. The silver nanoparticles deposited on the hydrophobic papers (photographic paper, graph paper, and weighing paper) were evenly and densely arranged. While in-homogeneous distribution was observed on the hydrophilic printing paper. It can be found that the AgNPs-photographic paper with the maximum contact angle exhibited the highest SERS enhancement. The detection limit for thiram adsorbed on the AgNPs-photographic paper was 10-10 mol/L, which was lower than the others. Good linear responses (R2 = 0.9918, 0.9897) between the SERS intensities and logarithmic concentrations were obtained from 104 to 10-10 mol/L. Moreover, the substrate had good uniformity and reproducibility with relative standard deviation values of 4.20% and 4.90% measured by eight points and ten substrates, respectively. The AgNPs-photographic paper exhibited high stability within eight months.
Collapse
Affiliation(s)
- Junli Duan
- Department of Physics, Shanghai Normal University, Shanghai 200234, PR China
| | - Zhiyu Qiu
- Department of Physics, Shanghai Normal University, Shanghai 200234, PR China
| | - Ling Li
- Department of Physics, Shanghai Normal University, Shanghai 200234, PR China
| | - Longxiu Feng
- Department of Physics, Shanghai Normal University, Shanghai 200234, PR China
| | - Lei Huang
- Department of Physics, Shanghai Normal University, Shanghai 200234, PR China
| | - Guina Xiao
- Department of Physics, Shanghai Normal University, Shanghai 200234, PR China.
| |
Collapse
|
20
|
Zhang Y, Li L, Gao Y, Wang X, Sun L, Ji W, Ozaki Y. Nitrosonaphthol reaction-assisted SERS assay for selective determination of 5-hydroxyindole-3-acetic acid in human urine. Anal Chim Acta 2020; 1134:34-40. [DOI: 10.1016/j.aca.2020.08.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 08/10/2020] [Accepted: 08/12/2020] [Indexed: 12/29/2022]
|
21
|
Yan F, Ma X, Jin Q, Tong Y, Tang H, Lin X, Liu J. Phenylboronic acid-functionalized vertically ordered mesoporous silica films for selective electrochemical determination of fluoride ion in tap water. Mikrochim Acta 2020; 187:470. [DOI: 10.1007/s00604-020-04422-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 06/30/2020] [Indexed: 02/01/2023]
|
22
|
Wang X, Zhang Q, Kang Q, Zou G, Shen D. A high sensitive single luminophore ratiometric electrochemiluminescence immunosensor in combined with anodic stripping voltammetry. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135725] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
23
|
Abstract
Potentiometric probes used in direct potentiometry are attractive sensing tools. They give information on ion activities, which is often uniquely useful. If, instead, concentrations are desired as sensor output, the ionic strength of the sample must be precisely known, which is often not possible. Here, for the first time, direct potentiometry can be made to report concentrations, rather than activities. It is demonstrated for the detection of monovalent anionic species by using a self-referencing Ag/AgI pulstrode as the reference element instead of a traditional reference electrode. This reference pulstrode releases a discrete quantity of iodide ions from the electrode and the resulting reference potential varies with the activity coefficient of iodide. The effects of activity coefficient on the indicator and reference electrode are therefore compensated and the observed cell potential may now be described in a Nernstian manner against anion concentration, rather than activity. Theoretical simulations and experimental results support the validity of this approach. For most monovalent anions of practical relevance, the potential difference between this approach and from a traditional activity coefficient calculation is less than 0.5 mV. The concept is validated with an all-solid-state nitrate sensor as well as a commercial fluoride-selective electrode, giving Nernstian responses in different ionic strength backgrounds against concentration without the need for correcting activity coefficients or liquid junction potentials.
Collapse
Affiliation(s)
- Wenyue Gao
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| | - Xiaojiang Xie
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland
| |
Collapse
|