1
|
Shirani E, Razmjou A, Asadnia M, Nordon RE, Inglis DW. Surface Modification of Polystyrene with Boronic Acid for Immunoaffinity-Based Cell Enrichment. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:4361-4372. [PMID: 38357828 DOI: 10.1021/acs.langmuir.3c03644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/16/2024]
Abstract
Obtaining an enriched and phenotypically pure cell population from heterogeneous cell mixtures is important for diagnostics and biosensing. Existing techniques such as fluorescent-activated cell sorting (FACS) and magnetic-activated cell sorting (MACS) require preincubation with antibodies (Ab) and specialized equipment. Cell immunopanning removes the need for preincubation and can be done with no specialized equipment. The majority of the available antibody-mediated analyte capture techniques require a modification to the Abs for binding. In this work, no antibody modification is used because we take advantage of the carbohydrate chain in the Fc region of Ab. We use boronic acid as a cross-linker to bind the Ab to a modified surface. The process allows for functional orientation and cleavable binding of the Ab. In this study, we created an immunoaffinity matrix on polystyrene (PS), an inexpensive and ubiquitous plastic. We observed a 37% increase in Ab binding compared with that of a passive adsorption approach. The method also displayed a more consistent antibody binding with 17 times less variation in Ab loading among replicates than did the passive adsorption approach. Surface topography analysis revealed that a dextran coating reduced nonspecific antibody binding. Elemental analysis (XPS) was used to characterize the surface at different stages and showed that APBA molecules can bind upside-down on the surface. While upside-down antibodies likely remain functional, their elution behavior might differ from those bound in the desired way. Cell capture experiments show that the new surface has 43% better selectivity and 2.4-fold higher capture efficiency compared to a control surface of passively adsorbed Abs. This specific surface chemistry modification will allow the targeted capture of cells or analytes with the option of chemical detachment for further research and characterization.
Collapse
Affiliation(s)
- Elham Shirani
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | - Amir Razmjou
- Mineral Recovery Research Center (MRRC), School of Engineering, Edith Cowan University, Joondalup, Perth, Western Australia 6027, Australia
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | - Robert E Nordon
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - David W Inglis
- School of Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| |
Collapse
|
2
|
Sousa S, Fernandes M, Correia da Costa JM. Serotyping, a challenging approach for Toxoplasma gondii typing. Front Med (Lausanne) 2023; 10:1111509. [PMID: 37089607 PMCID: PMC10115974 DOI: 10.3389/fmed.2023.1111509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 03/20/2023] [Indexed: 04/08/2023] Open
Abstract
Genotype analysis has revealed a high genetic diversity in strains of Toxoplasma gondii, isolated from a wide range of intermediate hosts and different geographic origins. Diversity is notably striking for parasites from wild hosts in South America, generally referred as non-archetypal genotypes. Those genotypes are implicated in the etiology of severe clinical disease, multivisceral toxoplasmosis, associated with high rate of mortality in immunocompetent individuals. Can we accept specific antibodies produced during T. gondii infection as biomarkers to identify infecting genotypes? Scientific evidence supports a positive response to this question; however, the genetic diversity of T. gondii genotypes organized into 16 haplogroups and collectively defined in 6 major clades, provides a reminder of the complexity and difficulty for the purpose. This review discusses serological approaches to genotyping T. gondii.
Collapse
Affiliation(s)
- Susana Sousa
- Center for the Study of Animal Science (CECA), University of Porto, Porto, Portugal
- Department of Infectious Diseases, R&D Unit, National Health Institute Dr. Ricardo Jorge (INSA), Porto, Portugal
- Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), University of Porto, Porto, Portugal
- Associated Laboratory for Green Chemistry (LAQV) of the Network of Chemistry and Technology (REQUIMTE), Department of Chemistry and Biochemistry, Faculty of Sciences, University of Porto, Porto, Portugal
- *Correspondence: Susana Sousa,
| | - Maria Fernandes
- Center for the Study of Animal Science, University of Porto, Porto, Portugal
| | - José Manuel Correia da Costa
- Center for the Study of Animal Science (CECA), University of Porto, Porto, Portugal
- Department of Infectious Diseases, R&D Unit, National Health Institute Dr. Ricardo Jorge (INSA), Porto, Portugal
- Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), University of Porto, Porto, Portugal
| |
Collapse
|
3
|
Metal Nanoparticle and Quantum Dot Tags for Signal Amplification in Electrochemical Immunosensors for Biomarker Detection. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9040085] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
With the increasing importance of healthcare and clinical diagnosis, as well as the growing demand for highly sensitive analytical instruments, immunosensors have received considerable attention. In this review, electrochemical immunosensor signal amplification strategies using metal nanoparticles (MNPs) and quantum dots (Qdots) as tags are overviewed, focusing on recent developments in the ultrasensitive detection of biomarkers. MNPs and Qdots can be used separately or in combination with other nanostructures, while performing the function of nanocarriers, electroactive labels, or catalysts. Thus, different functions of MNPs and Qdots as well as recent advances in electrochemical signal amplification are discussed. Additionally, the methods most often used for antibody immobilization on nanoparticles, immunoassay formats, and electrochemical methods for indirect biomarker detection are overviewed.
Collapse
|
4
|
Latrofa MS, Palmisano G, Annoscia G, Pierri CL, Chandrashekar R, Otranto D. Major antigen and paramyosin proteins as candidate biomarkers for serodiagnosis of canine infection by zoonotic Onchocerca lupi. PLoS Negl Trop Dis 2021; 15:e0009027. [PMID: 33566799 PMCID: PMC7875354 DOI: 10.1371/journal.pntd.0009027] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 12/02/2020] [Indexed: 11/25/2022] Open
Abstract
Onchocerca lupi (Spirurida: Onchocercidae) is a filarial worm parasitizing domestic carnivores and humans. Adult nematodes usually localize beneath in the sclera or in the ocular retrobulbar of infected animals, whilst microfilariae are found in the skin. Therefore, diagnosis of O. lupi is achieved by microscopic and/or molecular detection of microfilariae from skin biopsy and/or surgical removal of adults from ocular tissues of infected hosts. An urgent non-invasive diagnostic tool for the diagnosis of O. lupi in dog is mandatory. In this study, an immunoproteomic analyses was performed using a combination of immunoblotting and mass spectrometry techniques. Onchocerca lupi major antigen (Ol-MJA) and paramyosin (Ol-PARA) proteins were identified as potential biomarkers for serodiagnosis. Linear epitopes were herein scanned for both proteins using high-density peptide microarray. Sera collected from dog infected with O. lupi and healthy animal controls led to the identification of 11 immunodominant antigenic peptides (n = 7 for Ol-MJA; n = 4 for Ol-PARA). These peptides were validated using sera of dogs uniquely infected with the most important filarioids infesting dogs either zoonotic (Dirofilaria repens, Dirofilaria immitis) or not (Acanthocheilonema reconditum and Cercopithifilaria bainae). Overall, six antigenic peptides, three for Ol-MJA and for Ol-PARA, respectively, were selected as potential antigens for the serological detection of canine O. lupi infection. The molecular and proteomic dataset herein reported should provide a useful resource for studies on O. lupi toward supporting the development of new interventions (drugs, vaccines and diagnostics) against canine onchocercosis. The diagnosis of Onchocerca lupi (Spirurida: Onchocercidae), a zoonotic nematode of domestic animals, is currently based on microscopic examination of skin snip sediments and on the identification of adults embedded in ocular nodules or by molecular assays. An urgent non-invasive diagnostic tool for the diagnosis of O. lupi in dogs is mandatory. In this context, combined immunoblotting and mass spectrometry-based analyses have been performed to identify two proteins, major antigen and paramyosin, of O. lupi. Peptides herein identified represent suitable candidate biomarker for the development of a specific diagnostic test for canine onchocercosis. An accurate, minimally invasive diagnostic method could prove useful for the control of the canine diseases, for establishing large sero-surveys, for mapping the distribution of the infection in endemic areas as well as in areas where information on the disease is not available and for the reduction of risks for human infection.
Collapse
Affiliation(s)
| | - Giuseppe Palmisano
- Department of Parasitology, ICB, Glycoproteomics Laboratory, University of São Paulo, Brazil
| | - Giada Annoscia
- Department of Veterinary Medicine, University of Bari, Bari, Italy
| | - Ciro Leonardo Pierri
- Department of Biosciences, Biotechnologies and Biopharmaceutics, Laboratory of Biochemistry and Molecular Biology, University of Bari, Bari, Italy
| | | | - Domenico Otranto
- Department of Veterinary Medicine, University of Bari, Bari, Italy
- Department of Pathobiology, Faculty of Veterinary Science, Bu-Ali Sina University, Felestin Sq., Hamedan, Iran
- * E-mail:
| |
Collapse
|
5
|
Saini G, Trenchevska O, Howell LJ, Boyd JG, Smith DP, Jain V, Linford MR. Performance Comparison of Three Chemical Vapor Deposited Aminosilanes in Peptide Synthesis: Effects of Silane on Peptide Stability and Purity. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:11925-11932. [PMID: 30208711 DOI: 10.1021/acs.langmuir.8b01298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Silicon oxide substrates underwent gas-phase functionalization with various aminosilanes, and the resulting surfaces were evaluated for their suitability as a solid support for solid phase peptide synthesis (SPPS). APTES (3-aminopropyltriethoxysilane), APDEMS (3-aminopropyldiethoxymethylsilane), and APDIPES (3-aminopropyldiisopropylethoxysilane) were individually applied to thermal oxide-terminated silicon substrates via gas-phase deposition. Coated surfaces were characterized by spectroscopic ellipsometry (SE), contact angle goniometry, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and spectrophotometry. Model oligopeptides with 16 residues were synthesized on the amino surfaces, and the chemical stabilities of the resulting surfaces were evaluated against a stringent side chain deprotection (SCD) step, which contained trifluoroacetic acid (TFA) and trifluoromethanesulfonic acid (TFMSA). Functionalized surface thickness loss during SCD was most acute for APDIPES and the observed relative stability order was APTES > APDEMS > APDIPES. Amino surfaces were evaluated for compatibility with stepwise peptide synthesis where complete deprotection and coupling cycles are paramount. Model trimer syntheses indicated that routine capping of unreacted amines with acetic anhydride significantly increased purity as measured by MALDI-MS. An inverse correlation between the amine loading density and peptide purity was observed. In general, peptide purity was highest for the lowest amine density APDIPES surface.
Collapse
Affiliation(s)
- Gaurav Saini
- HealthTell Inc. , Chandler , Arizona 85226 , United States
| | | | - Loren J Howell
- HealthTell Inc. , Chandler , Arizona 85226 , United States
| | - James G Boyd
- HealthTell Inc. , Chandler , Arizona 85226 , United States
| | - David P Smith
- HealthTell Inc. , Chandler , Arizona 85226 , United States
| | - Varun Jain
- Department of Chemistry and Biochemistry , Brigham Young University , Provo , Utah 84602 , United States
| | - Matthew R Linford
- Department of Chemistry and Biochemistry , Brigham Young University , Provo , Utah 84602 , United States
| |
Collapse
|
6
|
Adibi-Motlagh B, Lotfi AS, Rezaei A, Hashemi E. Cell attachment evaluation of the immobilized bioactive peptide on a nanographene oxide composite. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 82:323-329. [PMID: 29025665 DOI: 10.1016/j.msec.2017.05.039] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Revised: 04/25/2017] [Accepted: 05/07/2017] [Indexed: 11/27/2022]
Abstract
The immobilization of bioactive peptides as key molecules in numerous biological and physiological functions holds promise for designing advanced biomaterials. Graphene and its derivatives, having unique physicochemical properties, have brought considerable attention in the life sciences. In this regard, the chemical manipulation of the graphene surface with bioactive peptides opens a new horizon to design bioactive materials for a variety of future nanobiotechnologies. In this study, the first straightforward strategy for the covalent immobilization of the cell-adhesion peptide onto the graphene surface based on the Ugi four-component assembly process (Ugi 4-CAP) will be presented. The modified adhesion motif peptide, as an amine component in the presence of formaldehyde, cyclohexylisocyanide and carboxylated-graphene (G-COOH), was adopted in a four component reaction to fabricate a peptide-graphene (Peptide-G) biomaterial in water as a green solvent at an ambient temperature. The amino functional groups corresponded to the modified adhesion motif peptide and were immobilized onto the graphene sheets, which were quantified by the Kaiser test. The sheets were characterized by further analyses with FT-IR, AFM, UV-vis, Raman and thermogravimetric analyses. The Peptide-G biomaterial showed excellent biocompatibility. In addition, the Peptide-G treated surface, due to the presence of RGD on the surface of the graphene, significantly accelerated the proliferation of human mesenchymal stem cells (hMSCs) at a better rate regarding the tissue plate.
Collapse
Affiliation(s)
- Behzad Adibi-Motlagh
- Department of Clinical Biochemistry, Faculty of Medical Science, Tarbiat Modares University, Tehran, Iran
| | - Abbas Sahebghadam Lotfi
- Department of Clinical Biochemistry, Faculty of Medical Science, Tarbiat Modares University, Tehran, Iran.
| | - Aram Rezaei
- Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Ehsan Hashemi
- National Research Center for Transgenic Mouse, National Institute of Genetic Engineering and Biotechnology, P.O. Box 14965-161, Tehran, Iran
| |
Collapse
|
7
|
Lagatie O, Van Dorst B, Stuyver LJ. Identification of three immunodominant motifs with atypical isotype profile scattered over the Onchocerca volvulus proteome. PLoS Negl Trop Dis 2017; 11:e0005330. [PMID: 28125577 PMCID: PMC5295699 DOI: 10.1371/journal.pntd.0005330] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 02/07/2017] [Accepted: 01/14/2017] [Indexed: 01/30/2023] Open
Abstract
Understanding the immune response upon infection with the filarial nematode Onchocerca volvulus and the mechanisms that evolved in this parasite to evade immune mediated elimination is essential to expand the toolbox available for diagnostics, therapeutics and vaccines development. Using high-density peptide microarrays we scanned the proteome-wide linear epitope repertoire in Cameroonian onchocerciasis patients and healthy controls from Southern Africa which led to the identification of 249 immunodominant antigenic peptides. Motif analysis learned that 3 immunodominant motifs, encompassing 3 linear epitopes, are present in 70, 43, and 31 of these peptides, respectively and appear to be scattered over the entire proteome in seemingly non-related proteins. These linear epitopes are shown to have an atypical isotype profile dominated by IgG1, IgG3, IgE and IgM, in contrast to the commonly observed IgG4 response in chronic active helminth infections. The identification of these linear epitope motifs may lead to novel diagnostic development but further evaluation of cross-reactivity against common co-infecting human nematode infections will be needed. Infection with the filarial parasite Onchocerca volvulus is the cause of river blindness. We analyzed the immune response against this parasite in infected individuals in order to identify linear epitopes. Using high-density peptide microarrays we discovered three immunodominant motifs in the Onchocerca volvulus proteome that induce a broad IgG response, but the typical IgG4 immune response against parasites was absent. Our study led to the identification of novel potential epitope sequences that can potentially be used for detection of infection with Onchocerca volvulus.
Collapse
Affiliation(s)
- Ole Lagatie
- Janssen Diagnostics, Janssen Pharmaceutica NV, Beerse, Belgium
- * E-mail:
| | - Bieke Van Dorst
- Janssen Diagnostics, Janssen Pharmaceutica NV, Beerse, Belgium
| | | |
Collapse
|
8
|
He JL, Wang DS, Fan SK. Opto-Microfluidic Immunosensors: From Colorimetric to Plasmonic. MICROMACHINES 2016; 7:E29. [PMID: 30407402 PMCID: PMC6189923 DOI: 10.3390/mi7020029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2015] [Revised: 01/25/2016] [Accepted: 02/04/2016] [Indexed: 02/06/2023]
Abstract
Optical detection has long been the most popular technique in immunosensing. Recent developments in the synthesis of luminescent probes and the fabrication of novel nanostructures enable more sensitive and efficient optical detection, which can be miniaturized and integrated with microfluidics to realize compact lab-on-a-chip immunosensors. These immunosensors are portable, economical and automated, but their sensitivity is not compromised. This review focuses on the incorporation and implementation of optical detection and microfluidics in immunosensors; it introduces the working principles of each optical detection technique and how it can be exploited in immunosensing. The recent progress in various opto-microfluidic immunosensor designs is described. Instead of being comprehensive to include all opto-microfluidic platforms, the report centers on the designs that are promising for point-of-care immunosensing diagnostics, in which ease of use, stability and cost-effective fabrication are emphasized.
Collapse
Affiliation(s)
- Jie-Long He
- Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan.
| | - Da-Shin Wang
- Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan.
| | - Shih-Kang Fan
- Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan.
| |
Collapse
|
9
|
Besret S, Vicogne J, Dahmani F, Fafeur V, Desmet R, Drobecq H, Romieu A, Melnyk P, Melnyk O. Thiocarbamate-linked polysulfonate-peptide conjugates as selective hepatocyte growth factor receptor binders. Bioconjug Chem 2014; 25:1000-10. [PMID: 24749766 PMCID: PMC4064695 DOI: 10.1021/bc500137j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
The capacity of many proteins to interact with natural or synthetic polyanions has been exploited for modulating their biological action. However, the polydispersity of these macromolecular polyanions as well as their poor specificity is a severe limitation to their use as drugs. An emerging trend in this field is the synthesis of homogeneous and well-defined polyanion-peptide conjugates, which act as bivalent ligands, with the peptide part bringing the selectivity of the scaffold. Alternately, this strategy can be used for improving the binding of short peptides to polyanion-binding protein targets. This work describes the design and first synthesis of homogeneous polysulfonate-peptide conjugates using thiocarbamate ligation for binding to the extracellular domain of MET tyrosine kinase receptor for hepatocyte growth factor.
Collapse
|
10
|
Gray CJ, Weissenborn MJ, Eyers CE, Flitsch SL. Enzymatic reactions on immobilised substrates. Chem Soc Rev 2014; 42:6378-405. [PMID: 23579870 DOI: 10.1039/c3cs60018a] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
This review gives an overview of enzymatic reactions that have been conducted on substrates attached to solid surfaces. Such biochemical reactions have become more important with the drive to miniaturisation and automation in chemistry, biology and medicine. Technical aspects such as choice of solid surface and analytical methods are discussed and examples of enzyme reactions that have been successful on these surfaces are provided.
Collapse
Affiliation(s)
- Christopher J Gray
- School of Chemistry & Manchester Institute of Biotechnology, The University of Manchester, 131 Princess Road, Manchester, M1 7DN, UK
| | | | | | | |
Collapse
|
11
|
Site-directed antibody immobilization techniques for immunosensors. Biosens Bioelectron 2013; 50:460-71. [PMID: 23911661 DOI: 10.1016/j.bios.2013.06.060] [Citation(s) in RCA: 197] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Revised: 06/14/2013] [Accepted: 06/26/2013] [Indexed: 02/07/2023]
Abstract
Immunosensor sensitivity, regenerability, and stability directly depend on the type of antibodies used for the immunosensor design, quantity of immobilized molecules, remaining activity upon immobilization, and proper orientation on the sensing interface. Although sensor surfaces prepared with antibodies immobilized in a random manner yield satisfactory results, site-directed immobilization of the sensing molecules significantly improves the immunosensor sensitivity, especially when planar supports are employed. This review focuses on the three most conventional site-directed antibody immobilization techniques used in immunosensor design. One strategy of immobilizing antibodies on the sensor surface is via affinity interactions with a pre-formed layer of the Fc binding proteins, e.g., protein A, protein G, Fc region specific antibodies or various recombinant proteins. Another immobilization strategy is based on the use of chemically or genetically engineered antibody fragments that can be attached to the sensor surface covered in gold or self-assembled monolayer via the sulfhydryl groups present in the hinge region. The third most common strategy is antibody immobilization via an oxidized oligosaccharide moiety present in the Fc region of the antibody. The principles, advantages, applications, and arising problems of these most often applied immobilization techniques are reviewed.
Collapse
|
12
|
El-Mahdi O, Melnyk O. α-Oxo aldehyde or glyoxylyl group chemistry in peptide bioconjugation. Bioconjug Chem 2013; 24:735-65. [PMID: 23578008 DOI: 10.1021/bc300516f] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Since the 1990s, α-oxo aldehyde or glyoxylic acid chemistry has inspired a vast array of synthetic tools for tailoring peptide or protein structures, for developing peptides endowed with novel physicochemical properties or biological functions, for assembling a large diversity of bioconjugates or hybrid materials, or for designing peptide-based micro or nanosystems. This past decade, important developments have enriched the α-oxo aldehyde synthetic tool box in peptide bioconjugation chemistry and explored novel applications. The aim of this review is to give a large overview of this creative field.
Collapse
Affiliation(s)
- Ouafâa El-Mahdi
- Université Sidi Mohamed Ben Abdellah, Faculté Polydisciplinaire de Taza, Morocco
| | | |
Collapse
|
13
|
Strategies to improve the surface plasmon resonance-based immmunodetection of bacterial cells. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-0975-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Dendane N, Melnyk O, Xu T, Grandidier B, Boukherroub R, Stiévenard D, Coffinier Y. Direct characterization of native chemical ligation of peptides on silicon nanowires. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2012; 28:13336-13344. [PMID: 22931112 DOI: 10.1021/la3030217] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We describe the site-specific and chemoselective immobilization of peptides on hydrogen-terminated silicon nanowires (SiNWs) using native chemical ligation (NCL) (i.e., the reaction of a thioester group with a cysteine moiety to give a stable amide bond). The SiNWs investigated in this work were grown via a vapor-liquid-solid mechanism and functionalized with a thioester moiety. The immobilization of the peptides on the SiNWs was demonstrated by synthesizing peptides with an N-terminal cysteine residue and labeled with tetramethylrhodamine or trifluoromethyl groups that were detected by fluorescence and X-ray photoelectron spectroscopy, respectively. The peptides labeled with tetramethylrhodamine or trifluoromethyl groups for fluorescence or X-ray photoelectron spectroscopy (XPS) detection studies were synthesized with an N-terminal cysteine residue. N-Terminal seryl peptides and carboxy-terminated SiNWs were used as controls to demonstrate the chemoselectivity of the peptide immobilization.
Collapse
Affiliation(s)
- Nabil Dendane
- IBL, UMR CNRS 8161, 1 rue du professeur Calmette, Lille, France
| | | | | | | | | | | | | |
Collapse
|
15
|
Abstract
Enzymes are key molecules in signal-transduction pathways. However, only a small fraction of more than 500 human kinases, 300 human proteases and 200 human phosphatases is characterised so far. Peptide microarray based technologies for extremely efficient profiling of enzyme substrate specificity emerged in the last years. This technology reduces set-up time for HTS assays and allows the identification of downstream targets. Moreover, peptide microarrays enable optimisation of enzyme substrates. Focus of this review is on assay principles for measuring activities of kinases, phosphatases or proteases and on substrate identification/optimisation for kinases. Additionally, several examples for reliable identification of substrates for lysine methyl-transferases, histone deacetylases and SUMO-transferases are given. Finally, use of high-density peptide microarrays for the simultaneous profiling of kinase activities in complex biological samples like cell lysates or lysates of complete organisms is described. All published examples of peptide arrays used for enzyme profiling are summarised comprehensively.
Collapse
|
16
|
Maksimov P, Zerweck J, Maksimov A, Hotop A, Groß U, Spekker K, Däubener W, Werdermann S, Niederstrasser O, Petri E, Mertens M, Ulrich RG, Conraths FJ, Schares G. Analysis of clonal type-specific antibody reactions in Toxoplasma gondii seropositive humans from Germany by peptide-microarray. PLoS One 2012; 7:e34212. [PMID: 22470537 PMCID: PMC3314601 DOI: 10.1371/journal.pone.0034212] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2011] [Accepted: 02/28/2012] [Indexed: 11/18/2022] Open
Abstract
Background Different clonal types of Toxoplasma gondii are thought to be associated with distinct clinical manifestations of infections. Serotyping is a novel technique which may allow to determine the clonal type of T. gondii humans are infected with and to extend typing studies to larger populations which include infected but non-diseased individuals. Methodology A peptide-microarray test for T. gondii serotyping was established with 54 previously published synthetic peptides, which mimic clonal type-specific epitopes. The test was applied to human sera (n = 174) collected from individuals with an acute T. gondii infection (n = 21), a latent T. gondii infection (n = 53) and from T. gondii-seropositive forest workers (n = 100). Findings The majority (n = 124; 71%) of all T. gondii seropositive human sera showed reactions against synthetic peptides with sequences specific for clonal type II (type II peptides). Type I and type III peptides were recognized by 42% (n = 73) or 16% (n = 28) of the human sera, respectively, while type II–III, type I–III or type I–II peptides were recognized by 49% (n = 85), 36% (n = 62) or 14% (n = 25) of the sera, respectively. Highest reaction intensities were observed with synthetic peptides mimicking type II-specific epitopes. A proportion of the sera (n = 22; 13%) showed no reaction with type-specific peptides. Individuals with acute toxoplasmosis reacted with a statistically significantly higher number of peptides as compared to individuals with latent T. gondii infection or seropositive forest workers. Conclusions Type II-specific reactions were overrepresented and higher in intensity in the study population, which was in accord with genotyping studies on T. gondii oocysts previously conducted in the same area. There were also individuals with type I- or type III-specific reactions. Well-characterized reference sera and further specific peptide markers are needed to establish and to perform future serotyping approaches with higher resolution.
Collapse
Affiliation(s)
- Pavlo Maksimov
- Federal Research Institute for Animal Health, Institute of Epidemiology, Friedrich-Loeffler-Institut, Wusterhausen, Germany
- * E-mail: (PM); (GS)
| | | | - Aline Maksimov
- Federal Research Institute for Animal Health, Institute of Epidemiology, Friedrich-Loeffler-Institut, Wusterhausen, Germany
| | - Andrea Hotop
- German National Consulting Laboratory for Toxoplasmosis, Department of Medical Microbiology, University Medical Center Göttingen, Göttingen, Germany
| | - Uwe Groß
- German National Consulting Laboratory for Toxoplasmosis, Department of Medical Microbiology, University Medical Center Göttingen, Göttingen, Germany
| | - Katrin Spekker
- Institute of Medical Microbiology and Hospital Hygiene, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Walter Däubener
- Institute of Medical Microbiology and Hospital Hygiene, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | | | | | | | - Marc Mertens
- Federal Research Institute for Animal Health, Institute for Novel and Emerging Infectious Diseases, Friedrich-Loeffler-Institut, Greifswald - Insel Riems, Germany
| | - Rainer G. Ulrich
- Federal Research Institute for Animal Health, Institute for Novel and Emerging Infectious Diseases, Friedrich-Loeffler-Institut, Greifswald - Insel Riems, Germany
| | - Franz J. Conraths
- Federal Research Institute for Animal Health, Institute of Epidemiology, Friedrich-Loeffler-Institut, Wusterhausen, Germany
| | - Gereon Schares
- Federal Research Institute for Animal Health, Institute of Epidemiology, Friedrich-Loeffler-Institut, Wusterhausen, Germany
- * E-mail: (PM); (GS)
| |
Collapse
|
17
|
Comparison of techniques to screen and characterize bacteria-specific hybridomas for high-quality monoclonal antibodies selection. Anal Biochem 2011; 421:26-36. [PMID: 22033288 DOI: 10.1016/j.ab.2011.10.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2011] [Revised: 09/28/2011] [Accepted: 10/02/2011] [Indexed: 11/22/2022]
Abstract
Antibodies are very important materials for diagnostics. A rapid and simple hybridoma screening method will help in delivering specific monoclonal antibodies. In this study, we systematically developed the first antibody array to screen for bacteria-specific monoclonal antibodies using Listeria monocytogenes as a bacteria model. The antibody array was developed to expedite the hybridoma screening process by printing hybridoma supernatants on a glass slide coated with an antigen of interest. This screening method is based on the binding ability of supernatants to the coated antigen. The bound supernatants were detected by a fluorescently labeled anti-mouse immunoglobulin. Conditions (slide types, coating, spotting, and blocking buffers) for antibody array construction were optimized. To demonstrate its usefulness, antibody array was used to screen a sample set of 96 hybridoma supernatants in comparison to ELISA. Most of the positive results identified by ELISA and antibody array methods were in agreement except for those with low signals that were undetectable by antibody array. Hybridoma supernatants were further characterized with surface plasmon resonance to obtain additional data on the characteristics of each selected clone. While the antibody array was slightly less sensitive than ELISA, a much faster and lower cost procedure to screen clones against multiple antigens has been demonstrated.
Collapse
|
18
|
Samanta D, Sarkar A. Immobilization of bio-macromolecules on self-assembled monolayers: methods and sensor applications. Chem Soc Rev 2011; 40:2567-92. [DOI: 10.1039/c0cs00056f] [Citation(s) in RCA: 313] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
19
|
Cretich M, Damin F, Longhi R, Gotti C, Galati C, Renna L, Chiari M. Peptide microarrays on coated silicon slides for highly sensitive antibody detection. Methods Mol Biol 2010; 669:147-60. [PMID: 20857364 DOI: 10.1007/978-1-60761-845-4_12] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Peptides, with their well-established chemistry and fully automated synthesis, provide an invaluable tool for the screening of protein ligands, for epitope mapping, and for antibody diagnostics on the microarray format.The method described in this chapter shows that the sensitivity of a peptide-based microimmunoassay is greatly improved by using a new, specifically developed substrate made of silicon coated by an optimized layer of silicon oxide. A set of six peptides corresponding to the sequences of human and rat acetylcholine receptor subunits was immobilized on glass and silicon slides coated by a copolymer of N,N-dimethylacrylamide, N-acryloyloxysuccinimide, and 3-(trimethoxysilyl) propyl methacrylate, copoly(DMA-NAS-MAPS). The spotted probes were incubated with rabbit anti-sera and with purified antibodies raised against the corresponding peptides. The coated silicon slides, in comparison against the glass substrates, showed a five- to tenfold enhancement of the fluorescence signals, leading to the specific detection of the full set of antibodies down to a concentration of 0.5-1 ng/mL in serum. The sensitivity provided by the test allows its use for the diagnosis of antibodies in clinical samples.
Collapse
Affiliation(s)
- Marina Cretich
- Istituto di Chimica del Riconoscimento Molecolare C.N.R, Milano, Italy
| | | | | | | | | | | | | |
Collapse
|
20
|
Masch A, Zerweck J, Reimer U, Wenschuh H, Schutkowski M. Antibody signatures defined by high-content peptide microarray analysis. Methods Mol Biol 2010; 669:161-72. [PMID: 20857365 DOI: 10.1007/978-1-60761-845-4_13] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Circulating antibodies are highly selective binding reagents directed to a vast repertoire of antigens. Candidate antigens displayed as overlapping peptides on microarrays can be used to screen for recognition by serum antibodies from clinically well-defined patient populations. The methodology is robust and enables unbiased visualization of antigen-specific B-cell responses. Additionally, autoantibody signatures of diagnostic value could be detected using microarrays displaying thousands of human peptides.
Collapse
|
21
|
Souplet V, Desmet R, Melnyk O. In Situ Ligation between Peptides and Silica Nanoparticles for Making Peptide Microarrays on Polycarbonate. Bioconjug Chem 2009; 20:550-7. [DOI: 10.1021/bc800474g] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Vianney Souplet
- Institut de Biologie de Lille, UMR CNRS 8161, Universités de Lille 1 et 2, Institut Pasteur de Lille, IFR 142, 1 rue du Professeur Calmette, 59021 Lille Cedex, France
| | - Rémi Desmet
- Institut de Biologie de Lille, UMR CNRS 8161, Universités de Lille 1 et 2, Institut Pasteur de Lille, IFR 142, 1 rue du Professeur Calmette, 59021 Lille Cedex, France
| | - Oleg Melnyk
- Institut de Biologie de Lille, UMR CNRS 8161, Universités de Lille 1 et 2, Institut Pasteur de Lille, IFR 142, 1 rue du Professeur Calmette, 59021 Lille Cedex, France
| |
Collapse
|
22
|
Abstract
Polyclonal antibodies raised against full-length antigens are often used for localization experiments. Exact knowledge of epitopes in the antigen recognized by the antiserum is important if the target antigen belongs to a large family of proteins which are highly conserved. We have shown that epitope mapping using peptide microarrays represents a powerful tool for determination of immunodominat regions in a proteome-wide manner. As examples we show results of epitope mapping using peptide microarrays displaying overlapping peptide scans through either all human cyclophilins or all human FK506-binding proteins.
Collapse
Affiliation(s)
- Alexandra Thiele
- Max Planck Research Unit for Enzymology of Protein Folding, Weinbergweg 22, 06120 Halle, Germany
| |
Collapse
|
23
|
Abstract
Enzymes are key molecules in signal transduction pathways. However, only a small fraction of more than 500 predicted human kinases, 250 proteases and 250 phosphatases is characterized so far. Peptide microarray-based technologies for extremely efficient profiling of enzyme substrate specificity emerged in the last years. Additionally, patterns of enzymatic activities could be used to fingerprint the status of cells or organisms. This technology reduces set-up time for HTS assays and allows the identification of downstream targets. Moreover, peptide microarrays enable optimization of enzyme substrates. A comprehensive overview regarding enzyme profiling using peptide microarrays is presented with special focus on assay principles.
Collapse
Affiliation(s)
- Alexandra Thiele
- Max Planck Research Unit for Enzymology of Protein Folding, Halle, Germany
| | | | | |
Collapse
|
24
|
Abstract
Microarrays are frequently prepared on microscope glass slides. However, glass substrates can break or cut and thus can lead to the contamination of the manipulator during the analysis of biological samples. Alternately, bisphenol A polycarbonate (PC) is shock-resistant and, in addition, is easily eliminated by incineration. We show here that PC is a useful substrate for peptide microarray preparation. We describe in particular the preparation of peptide microarrays on PC using semicarbazide-functionalized silica nanoparticles and in situ semicarbazone ligation with glyoxylyl-peptides. The microarrays were used for the detection of antibodies using fluorescence detection.
Collapse
Affiliation(s)
- Vianney Souplet
- UMR CNRS 8161 Institut de Biologie de Lille 1, Lille Cedex, France
| | | | | |
Collapse
|
25
|
Jonkheijm P, Weinrich D, Schröder H, Niemeyer CM, Waldmann H. Chemical strategies for generating protein biochips. Angew Chem Int Ed Engl 2008; 47:9618-47. [PMID: 19025742 DOI: 10.1002/anie.200801711] [Citation(s) in RCA: 427] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Protein biochips are at the heart of many medical and bioanalytical applications. Increasing interest has been focused on surface activation and subsequent functionalization strategies for immobilizing these biomolecules. Different approaches using covalent and noncovalent chemistry are reviewed; particular emphasis is placed on the chemical specificity of protein attachment and on retention of protein function. Strategies for creating protein patterns (as opposed to protein arrays) are also outlined. An outlook on promising and challenging future directions for protein biochip research and applications is also offered.
Collapse
Affiliation(s)
- Pascal Jonkheijm
- Department of Chemical Biology, Max Planck Institute of Molecular Physiology and Faculty of Chemistry, Chemical Biology, Technical University of Dortmund, Otto Hahn Strasse 11, 44227 Dortmund, Germany
| | | | | | | | | |
Collapse
|
26
|
Jonkheijm P, Weinrich D, Schröder H, Niemeyer C, Waldmann H. Chemische Verfahren zur Herstellung von Proteinbiochips. Angew Chem Int Ed Engl 2008. [DOI: 10.1002/ange.200801711] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
27
|
Marcon L, Stiévenard D, Melnyk O. Characterization of Nanogap Chemical Reactivity Using Peptide-Capped Gold Nanoparticles and Electrical Detection. Bioconjug Chem 2008; 19:802-5. [DOI: 10.1021/bc8000084] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Lionel Marcon
- Institut d’Electronique de Microélectronique et de Nanotechnologie, UMR CNRS 8520, Dpt ISEN, 41 Bd Vauban, 59046 Lille Cedex, France, and Institut de Biologie de Lille, UMR CNRS 8161, Universités de Lille 1 et 2, Institut Pasteur de Lille, IFR 142, 1 rue du Professeur Calmette, 59021 Lille Cedex, France
| | - Didier Stiévenard
- Institut d’Electronique de Microélectronique et de Nanotechnologie, UMR CNRS 8520, Dpt ISEN, 41 Bd Vauban, 59046 Lille Cedex, France, and Institut de Biologie de Lille, UMR CNRS 8161, Universités de Lille 1 et 2, Institut Pasteur de Lille, IFR 142, 1 rue du Professeur Calmette, 59021 Lille Cedex, France
| | - Oleg Melnyk
- Institut d’Electronique de Microélectronique et de Nanotechnologie, UMR CNRS 8520, Dpt ISEN, 41 Bd Vauban, 59046 Lille Cedex, France, and Institut de Biologie de Lille, UMR CNRS 8161, Universités de Lille 1 et 2, Institut Pasteur de Lille, IFR 142, 1 rue du Professeur Calmette, 59021 Lille Cedex, France
| |
Collapse
|
28
|
Roux C, Chai F, Ollivier N, Ochsenbein A, Winter S, Melnyk O, Hildebrand HF. Ti-Cp functionalization by deposition of organic/inorganic silica nanoparticles. ACTA ACUST UNITED AC 2007; 24:549-54. [PMID: 17869178 DOI: 10.1016/j.bioeng.2007.08.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
In orthopaedics and cardiovascular surgery, titanium has become the metal of choice, due to its excellent mechanical properties and biocompatibility. In many surgical operations, chemicals and/or biomolecules (such as antibiotics or growth factors) are used in conjunction with prostheses, so as to avoid or stimulate targeted biological events. Often, immobilization instead of release of such molecules is preferred to optimize their effects, thus avoiding ectopic transformations. A versatile method for the functionalization of pure Ti is shown here, which allows the covalent immobilization of polypeptides. In order to avoid the hydrolysable Ti-O-Si bond found in directly silanized Ti, we use organic/inorganic silica colloids, derived from commercially available 25 nm Ludox silica nanoparticles. Prior to deposition onto Ti-Cp, the silica nanoparticles are functionalized by a propylsemicarbazide moiety by silanization. After spin-coating onto the Ti substrates, the colloids were shown by SEM to form a uniform layer, and to be very strongly adsorbed; the reactivity of the supported semicarbazide (Sc) functionalities being maintained. Chemoselective reaction of semicarbazide groups on the surface with aldehyde moieties present on the polypeptide of interest was chosen in this work due to its efficiency, to its compatibility with the proteinogenic amino acids and in particular cystein and to the use of mild experimental conditions. Aldehyde groups are also easily introduced onto polypeptides by synthesis, oxidation of N-terminal Ser residue or polysaccharide moieties of glycoproteins. Biological assays with MC3T3-E1 osteoblasts revealed an excellent cytocompatibility as shown by the assessment of cell viability, vitality and morphology.
Collapse
Affiliation(s)
- Clément Roux
- CNRS UMR 8161, 1 rue du professeur Calmette, F-59021 Lille Cedex, France
| | | | | | | | | | | | | |
Collapse
|
29
|
Abstract
In the past few years, protein biochips have emerged as promising proteomic and diagnostic tools for obtaining information about protein functions and interactions. Important technological innovations have been made. However, considerable development is still required, especially regarding protein immobilization, in order to fully realize the potential of protein biochips. In fact, protein immobilization is the key to the success of microarray technology. Proteins need to be immobilized onto surfaces with high density in order to allow the usage of small amount of sample solution. Nonspecific protein adsorption needs to be avoided or at least minimized in order to improve detection performances. Moreover, full retention of protein conformation and activity is a challenging task to be accomplished. Although a large number of review papers on protein biochips have been published in recent years, few have focused on protein immobilization technology. In this review, current protein immobilization strategies, including physical, covalent, and bioaffinity immobilization for the fabrication of protein biochips, are described. Particular consideration has been given to oriented immobilization, also referred to as site-specific immobilization, which is believed will improve homogeneous surface covering and accessibility of the active site.
Collapse
Affiliation(s)
- Federica Rusmini
- Department of Polymer Chemistry and Biomaterials (PBM), Institute for Biomedical Technology (BMTI), Faculty of Science and Technology, University of Twente, Enschede, 7500 AE, The Netherlands
| | | | | |
Collapse
|
30
|
Coffinier Y, Szunerits S, Jama C, Desmet R, Melnyk O, Marcus B, Gengembre L, Payen E, Delabouglise D, Boukherroub R. Peptide immobilization on amine-terminated boron-doped diamond surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2007; 23:4494-7. [PMID: 17367174 DOI: 10.1021/la063440y] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
This paper reports on the formation and characterization of semicarbazide termination on aminated boron-doped diamond (BDD) surfaces, and further preparation of peptide microarray through site-specific alpha-oxo semicarbazone ligation. Hydrogen-terminated BDD electrodes were first aminated using NH3 plasma treatment and then reacted with triphosgene and Fmoc-protected hydrazine to yield a protected semicarbazide termination. Subsequent deprotection and chemical reaction with glyoxylyl peptides led to the covalent immobilization of the peptides on the surface through site-specific ligation. The resulting surfaces were characterized using X-ray photoelectron spectroscopy (XPS) and fluorescence measurements.
Collapse
Affiliation(s)
- Yannick Coffinier
- Institut de Recherche Interdisciplinaire (IRI, FRE2963) and Institut d'Electronique, de Microélectronique et de Nanotechnologie (IEMN), Cité Scientifique, Avenue Poincaré - BP. 60069, 59652 Villeneuve d'Ascq, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Abstract
In the continuous drive to increase screening throughput and reduce sample requirement, microarray-based
technologies have risen to the occasion. In the past 7 years, a number of new methodologies have
been developed for preparing small molecule microarrays from combinatorial and natural product libraries
with the goal of identifying new interactions or enzymatic activities. Recent advances and applications
of small molecule microarrays are reviewed.
Collapse
|
32
|
Carion O, Souplet V, Olivier C, Maillet C, Medard N, El-Mahdi O, Durand JO, Melnyk O. Chemical Micropatterning of Polycarbonate for Site-Specific Peptide Immobilization and Biomolecular Interactions. Chembiochem 2007; 8:315-22. [PMID: 17226879 DOI: 10.1002/cbic.200600504] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Polycarbonate (PC) is a useful substrate for the preparation of microfluidic devices. Recently, its utility in bioanalysis has attracted much attention owing to the possibility of using compact discs as platforms for the high-throughput analysis of biomolecular interactions. In this article we report a novel method for the chemical micropatterning of polycarbonate based on the printing of functionalized silica nanoparticles. The semicarbazide groups present on the surface of the nanoparticles were used for the site-specific semicarbazone ligation of unprotected peptides derivatized by an alpha-oxoaldehyde group. The peptide micropatterns permitted the specific capture of antibodies. We report also the characterization of micropatterns on PC by using a wide-field optical imaging technique called Sarfus; this allows the detection of nm-thick films by using nonreflecting PC substrates and an optical microscope working with reflected differential interference contrast. The method described here is an easy way to modify polycarbonate surfaces for biomolecular interaction studies and should stimulate the use of PC for developing plastic biosensors.
Collapse
Affiliation(s)
- Olivier Carion
- UMR CNRS 8161 CNRS/Universités de Lille 1 et 2, Institut Pasteur de Lille, 1 rue du Professeur Calmette, 59021 Lille, France
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Sobek J, Aquino C, Schlapbach R. Quality considerations and selection of surface chemistry for glass-based DNA, peptide, antibody, carbohydrate, and small molecule microarrays. Methods Mol Biol 2007; 382:17-31. [PMID: 18220222 DOI: 10.1007/978-1-59745-304-2_2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The complexity of workflows for the production of high quality microarrays asks for the careful evaluation and implementation of materials and methods. As a cornerstone of the whole microarray process, the microarray substrate has to be chosen appropriately and a number of crucial considerations in respect to matching the research question with the technical requirements and possibilities have to be taken into account. In the following, how to lay the fundamental for high performance microarray experiments by evaluating basic quality requirements and the selection of suitable slide surface architectures for a variety of applications was concentrated.
Collapse
Affiliation(s)
- Jens Sobek
- Functional Genomics Center Zurich, Switzerland
| | | | | |
Collapse
|
34
|
Wang J, Uttamchandani M, Sun H, Yao S. Small Molecule Microarrays: Applications Using Specially Tagged Chemical Libraries. ACTA ACUST UNITED AC 2006. [DOI: 10.1002/qsar.200640083] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
35
|
Olivier C, Perzyna A, Coffinier Y, Grandidier B, Stiévenard D, Melnyk O, Durand JO. Detecting the chemoselective ligation of peptides to silicon with the use of cobalt-carbonyl labels. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2006; 22:7059-65. [PMID: 16863260 DOI: 10.1021/la060370m] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
While fluorescent-based methods are generally used to detect the immobilization and the interactions of biomolecules to solid supports, recent studies have shown their limitations in the case of silicon surfaces. As an alternative, we investigated the synthesis of peptides labeled with a metal transition complex and their subsequent immobilization to the silicon surfaces. The feasibility of using such probes has been explored by Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). By starting with hydrogen-terminated or oxidized silicon surfaces, we functionalized those surfaces with semicarbazide groups and showed the site-specific linkage of glyoxylyl peptides labeled with a Co2(CO)6 moiety.
Collapse
Affiliation(s)
- Christophe Olivier
- UMR CNRS 8161, Biological Institute of Lille, 1 rue du Professeur Calmette, 59021 Lille, France
| | | | | | | | | | | | | |
Collapse
|
36
|
Andresen H, Grötzinger C, Zarse K, Kreuzer OJ, Ehrentreich-Förster E, Bier FF. Functional peptide microarrays for specific and sensitive antibody diagnostics. Proteomics 2006; 6:1376-84. [PMID: 16456884 PMCID: PMC7167710 DOI: 10.1002/pmic.200500343] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Peptide microarrays displaying biologically active small synthetic peptides in a high-density format provide an attractive technology to probe complex samples for the presence and/or function of protein analytes. We present a new approach for manufacturing functional peptide microarrays for molecular immune diagnostics. Our method relies on the efficiency of site-specific solution-phase coupling of biotinylated synthetic peptides to NeutrAvidin (NA) and localized microdispensing of peptide-NA-complexes onto activated glass surfaces. Antibodies are captured in a sandwich manner between surface immobilized peptide probes and fluorescence-labeled secondary antibodies. Our work includes a total of 54 peptides derived from immunodominant linear epitopes of the T7 phage capsid protein, Herpes simplex virus glycoprotein D, c-myc protein, and three domains of the Human coronavirus polymerase polyprotein and their cognate mAbs. By using spacer molecules of different type and length for NA-mediated peptide presentation, we show that the incorporation of a minimum spacer length is imperative for antibody binding, whereas the peptide immobilization direction has only secondary importance for antibody affinity and binding. We further demonstrate that the peptide array is capable of detecting low-picomolar concentrations of mAbs in buffered solutions and diluted human serum with high specificity.
Collapse
Affiliation(s)
- Heiko Andresen
- Fraunhofer Institute for Biomedical Engineering, Department of Molecular Bioanalytics & Bioelectronics, Potsdam-Nuthetal, Germany.
| | | | | | | | | | | |
Collapse
|
37
|
Wegner GJ, Wark AW, Lee HJ, Codner E, Saeki T, Fang S, Corn RM. Real-time surface plasmon resonance imaging measurements for the multiplexed determination of protein adsorption/desorption kinetics and surface enzymatic reactions on peptide microarrays. Anal Chem 2006; 76:5677-84. [PMID: 15456285 DOI: 10.1021/ac0494275] [Citation(s) in RCA: 156] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The kinetics of protein adsorption/desorption onto peptide microarrays was studied using real-time surface plasmon resonance (SPR) imaging. S protein binding interactions were examined using an array composed of five different peptides: N terminal and C terminal immobilized wild-type S peptide (S1 and S2), an alternate binding sequence derived by phage display (LB2), an NVOC-protected S peptide, and a FLAG peptide control sequence (F). Kinetic measurements of the S protein-S1 peptide interaction were analyzed to determine a desorption rate constant (k(d)) of 1.1 (+/-0.08) x 10(-2) s(-1), an adsorption rate constant (k(a)) of 1.9 (+/-0.05) x 10(5) M(-1) s(-1), and an equilibrium adsorption constant (K(Ads)) of 1.7 (+/-0.08) x 10(7) M(-1). SPR imaging equilibrium measurements of S protein to S1 peptide were performed to independently confirm the kinetically determined value of K(Ads). Rate constants for the S2 and LB2 peptides on the array were measured as follows: 1.6 (+/-0.04) x 10(5) M(-1) s(-1) (k(a)) and 1.1 (+/-0.07) x 10(-2) s(-1) (k(d)) for S2, 1.2 (+/-0.05) x 10(5) M(-1) s(-1) (k(a)) and 1.1 (+/-0.03) x 10(-2) s(-1) (k(d)) for LB2. In addition to S protein adsorption/desorption, real-time SPR imaging of peptide arrays was applied to study the surface enzymatic activities of the protease factor Xa. Enzymatic cleavage of the substrate peptide (P1) was shown to follow first-order kinetics and proceed at a rate 10 times faster than that of the mutant peptide (P2), with cleavage velocities of 5.6 (+/-0.3) x 10(-4) s(-1) for P1 and 5.7 (+/-0.3) x 10(-5) s(-1) for P2.
Collapse
Affiliation(s)
- Greta J Wegner
- Department of Chemistry, University of Wisconsin, 1101 University Avenue, Madison, WI 53706, USA
| | | | | | | | | | | | | |
Collapse
|
38
|
Andresen H, Grötzinger C, Zarse K, Birringer M, Hessenius C, Kreuzer OJ, Ehrentreich-Förster E, Bier FF. Peptide microarrays with site-specifically immobilized synthetic peptides for antibody diagnostics. SENSORS AND ACTUATORS. B, CHEMICAL 2006; 113:655-663. [PMID: 32288236 PMCID: PMC7127650 DOI: 10.1016/j.snb.2005.07.033] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Peptide microarrays bear the potential to discover molecular recognition events on protein level, particularly in the field of molecular immunology, in a manner and with an efficiency comparable to the performance of DNA microarrays. We developed a novel peptide microarray platform for the detection of antibodies in liquid samples. The system comprises site-specific solution phase coupling of biotinylated peptides to NeutrAvidin, localized microdispensing of peptide-NeutrAvidin conjugates onto activated glass slides and a fluorescence immuno sandwich assay format for antibody capture and detection. Our work includes synthetic peptides deduced from amino acid sequences of immunodominant linear epitopes, such as the T7 phage capsid protein, Herpes simplex virus glycoprotein D, c-myc protein and three domains of the Human coronavirus 229E polymerase polyprotein. We demonstrate that our method produces peptide arrays with excellent spot morphology which are capable of specific and sensitive detection of monoclonal antibodies from fluid samples.
Collapse
Affiliation(s)
- Heiko Andresen
- Fraunhofer Institute for Biomedical Engineering, Department of Molecular Bioanalytics & Bioelectronics, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
| | - Carsten Grötzinger
- peptides&elephants GmbH, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
- Charité-Universitätsmedizin Berlin, Campus Virchow Hospital, Dept. Gastroenterology & Hepatology, Augustenburger Platz 1, D-13353 Berlin, Germany
| | - Kim Zarse
- Fraunhofer Institute for Biomedical Engineering, Department of Molecular Bioanalytics & Bioelectronics, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
- peptides&elephants GmbH, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
| | - Marc Birringer
- peptides&elephants GmbH, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
| | - Carsten Hessenius
- peptides&elephants GmbH, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
| | - Oliver J Kreuzer
- peptides&elephants GmbH, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
| | - Eva Ehrentreich-Förster
- Fraunhofer Institute for Biomedical Engineering, Department of Molecular Bioanalytics & Bioelectronics, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
| | - Frank F Bier
- Fraunhofer Institute for Biomedical Engineering, Department of Molecular Bioanalytics & Bioelectronics, Arthur-Scheunert-Allee 114-116, D-14558 Potsdam-Nuthetal, Germany
- University of Potsdam, Institute of Biochemistry and Biology, Potsdam, Germany
| |
Collapse
|
39
|
Marquette CA, Blum LJ. State of the art and recent advances in immunoanalytical systems. Biosens Bioelectron 2006; 21:1424-33. [PMID: 16337371 DOI: 10.1016/j.bios.2004.09.037] [Citation(s) in RCA: 145] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2004] [Revised: 09/02/2004] [Accepted: 09/03/2004] [Indexed: 11/24/2022]
Abstract
This article is an overview the state of the art and the recent developments in immunosensors. Homogeneous immunosensors, heterogeneous immunosensors, integrated immunosensors and biochip format immunosensors are presented, based on optical, electrochemical, magnetic or mechanical detection/transduction systems.
Collapse
Affiliation(s)
- Christophe A Marquette
- Laboratoire de Génie Enzymatique et Biomoléculaire, UMR 5013, CNRS Université Claude Bernard Lyon 1, Bât. CPE, Villeurbanne, France.
| | | |
Collapse
|
40
|
Tomizaki KY, Usui K, Mihara H. Protein-detecting microarrays: current accomplishments and requirements. Chembiochem 2006; 6:782-99. [PMID: 15791688 DOI: 10.1002/cbic.200400232] [Citation(s) in RCA: 154] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The sequencing of the human genome has been successfully completed and offers the chance of obtaining a large amount of valuable information for understanding complex cellular events simply and rapidly in a single experiment. Interestingly, in addressing these proteomic studies, the importance of protein-detecting microarray technology is increasing. In the coming few years, microarray technology will become a significantly promising and indispensable research/diagnostic tool from just a speculative technology. It is clear that the protein-detecting microarray is supported by three independent but strongly related technologies (surface chemistry, detection methods, and capture agents). Firstly, a variety of surface-modification methodologies are now widely available and offer site-specific immobilization of capture agents onto surfaces in such a way as to keep the native conformation and activity. Secondly, sensitive and parallel detection apparatuses are being developed to provide highly engineered microarray platforms for simultaneous data acquisition. Lastly, in the development of capture agents, antibodies are now probably the most prominent capture agents for analyzing protein abundances. Alternative scaffolds, such as phage-displayed antibody and protein fragments, which provide the advantage of increasing diversity of proteinic capture agents, however, are under development. An approach involving recombinant proteins fused with affinity tag(s) and coupled with a highly engineered surface chemistry will provide simple production protocols and specific orientations of capture agents on the microarray formats. Peptides and other small molecules can be employed in screening highly potent ligands as well as in measuring enzymatic activities. Protein-detecting microarrays supported by the three key technologies should contribute in accelerating diagnostic/biological research and drug discovery.
Collapse
Affiliation(s)
- Kin-ya Tomizaki
- Department of Bioengineering and The COE21 Program, Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, B-40, 4259 Nagatsuta, Midori, Yokohama 226-8501, Japan
| | | | | |
Collapse
|
41
|
Garcia JM, Far S, Diesis E, Melnyk O. Determination of glyoxylyl-peptide concentration using oxime chemistry and RP-HPLC analysis. J Pept Sci 2006; 12:734-8. [PMID: 16981231 DOI: 10.1002/psc.791] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Glyoxylyl-peptides are useful peptide derivatives in the context of hydrazone, oxime or thiazolidine ligations. We describe a method for the determination of glyoxylyl-peptide concentration based on the reaction of the alpha-oxo aldehyde group with an excess of O-benzylhydroxylamine. The amount of O-benzylhydroxylamine necessary to convert the alpha-oxo aldehyde group into the corresponding O-benzyloxime was determined by RP-HPLC analysis and corresponded to the quantity of glyoxylyl-peptide used in the experiment. The method is rapid, sensitive, accurate and allows the automated analysis of several samples.
Collapse
Affiliation(s)
- Jean-Michel Garcia
- UMR CNRS 8161, Biological Institute of Lille, 1 rue du Pr Calmette, 59021 Lille, France
| | | | | | | |
Collapse
|
42
|
Abstract
In order to improve the tissue integration and subsequently the long-term maintenance, the implant surface can be modified by mechanical, physical, chemical or biological functionalization. In this way, the surface becomes biologically active by further grafting of biomolecules. Two principal concepts are considered for materials functionalization. (i) The Drug Delivery Systems (DDS) where the bioactive molecules goes to the target. (ii) The grafting of the bioactive compounds on small strongly bound spacer molecules. In this system, the target goes to the bioactive molecules. These techniques provide promising outlooks for any polymeric or ceramic scaffold used in tissue engineering for the construction of whole artificial and functional organs.
Collapse
|
43
|
Joly P, Ardès-Guisot N, Kar S, Granier M, Durand JO, Melnyk O. Hybrid Bioorganic-Inorganic Materials Prepared by Site-Specific Ligation of Peptides to Functionalized Polydisperse Silica Particles. European J Org Chem 2005. [DOI: 10.1002/ejoc.200400839] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
44
|
Marquette CA, Imbert-Laurenceau E, Mallet F, Chaix C, Mandrand B, Blum LJ. Electroaddressed immobilization of recombinant HIV-1 P24 capsid protein onto screen-printed arrays for serological testing. Anal Biochem 2005; 340:14-23. [PMID: 15802125 DOI: 10.1016/j.ab.2005.01.041] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2004] [Indexed: 10/25/2022]
Abstract
A serological chemiluminescent biochip was designed based on screen-printed electrode arrays composed of nine 1-mm(2) electrodes. Arrays were shown to be produced with good batch-to-batch reproducibility (standard deviations of 4.4 and 12.0% for ferricyanide oxidation potential and current, respectively) and very good reproducibility within a particular array (2.0 and 7.5% standard deviations for the same controls). Electrode arrays were used to electroaddress various bioconjugate structures comprising a recombinant HIV-1 P24 capsid protein (RH24K) in polypyrrole film. Entrapment of RH24K preimmobilized onto maleic anhydride-alt-methyl vinyl ether copolymer was shown to be the more efficient immobilization procedure. This addressed sensing layer enabled the detection of anti-P24 antibodies at a concentration of 3.5 ng/ml through peroxidase-labeled anti-human immunoglobulin G reaction. The biochip was used to perform an HIV-1 serological test in human sera. HIV-1 seropositive and seronegative sera were easily discriminated using serum dilutions greater than 1/10,000.
Collapse
Affiliation(s)
- Christophe A Marquette
- Laboratoire de Génie Enzymatique et Biomoléculaire, EMB2 UMR 5013 CNRS-Université Lyon 1, Bâtiment CPE-43, Bd du 11 Novembre 1918-69622 Villeurbanne, Cedex, France.
| | | | | | | | | | | |
Collapse
|
45
|
Coffinier Y, Olivier C, Perzyna A, Grandidier B, Wallart X, Durand JO, Melnyk O, Stiévenard D. Semicarbazide-functionalized Si(111) surfaces for the site-specific immobilization of peptides. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2005; 21:1489-1496. [PMID: 15697299 DOI: 10.1021/la047781s] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The covalent attachment of semicarbazide-functionalized layers to hydrogen-terminated Si(111) surfaces is reported. The surface modification, based on the photoinduced hydrosilylation of a Si(111) surface with protected semicarbazide-functionalized alkenes, was investigated by means of X-ray photoelectron spectroscopy (XPS), contact angle measurements, and atomic force microscopy (AFM). The removal of the protecting group yielded a semicarbazide-terminated monolayer which was reacted with peptides bearing a glyoxylyl group for site-specific alpha-oxo semicarbazone ligation.
Collapse
Affiliation(s)
- Y Coffinier
- Institut d'Electronique et de Microélectronique et de Nanotechnologie, IEMN, (CNRS, UMR 8520) Département ISEN, 41 bd Vauban, 59046 Lille Cedex, France
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Marquette CA, Degiuli A, Imbert-Laurenceau E, Mallet F, Chaix C, Mandrand B, Blum LJ. Latex bead immobilisation in PDMS matrix for the detection of p53 gene point mutation and anti-HIV-1 capsid protein antibodies. Anal Bioanal Chem 2004; 381:1019-24. [PMID: 15599499 DOI: 10.1007/s00216-004-2862-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2004] [Revised: 06/28/2004] [Accepted: 09/14/2004] [Indexed: 10/26/2022]
Abstract
Two diagnostic chemiluminescent biochips were developed for either the detection of p53 gene point mutation or the serological detection of anti-HIV-1 p24 capsid protein. Both biochips were composed of 24 microarrays of latex beads spots (4x4) (150 microm in diameter, 800 microm spacing) entrapped in a poly(dimethylsiloxane) elastomer (PDMS). The latex beads, bearing oligonucleotide sequences or capsid protein, were spotted with a conventional piezoelectric spotter and subsequently transferred at the PDMS interface. The electron microscopy observation of the biochips showed how homogeneous and well distributed the spots could be. Point mutation detection on the codon 273 of the p53 gene was performed on the basis of the melting temperature difference between the perfect match sequence and the one base pair mismatch sequence. The hybridisation of a 20-mer oligonucleotide form the codon 273 including a one base pair mutation in its sequence on a biochip arrayed with non-muted and the muted complementary sequences, enabled a clear discrimination at 56 degrees C between muted and wild sequences. Moreover, the quantitative measurement of the amount of muted sequence in a sample was possible in the range 0.4-4 pmol. Serological measurement of anti-HIV-1 p24 capsid protein on the biochip, prepared with 1-microm-diameter latex beads, enabled the detection of monoclonal antibodies in the range 1.55-775 ng mL(-1). Such a range could be lowered to 0.775 ng mL(-1) when using 50-nm-diameter beads, which generated a higher specific surface. The validation of the biochip for the detection of anti-HIV-1 capsid protein antibodies was performed in human sera from seropositive and seronegative patients. The positivity of the sera was easily discriminated at serum dilutions below 1:1,000.
Collapse
Affiliation(s)
- Christophe A Marquette
- Laboratoire de Génie Enzymatique et Biomoléculaire, EMB2 UMR 5013 CNRS, Université Lyon 1, Bâtiment CPE - 43, Bd du 11 Novembre, 1918 - 69622, Villeurbanne, France.
| | | | | | | | | | | | | |
Collapse
|
47
|
Sakanyan V. Puces à protéines : nouvelle approche du diagnostic des maladies infectieuses. ACTA ACUST UNITED AC 2004. [DOI: 10.1016/s1294-5501(04)94261-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
48
|
Direct immobilization in poly(dimethylsiloxane) for DNA, protein and enzyme fluidic biochips. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2003.11.015] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
49
|
Far S, Melnyk O. A novel α,α ′ -diaminoacetic acid derivative for the introduction of the α-oxo aldehyde functionality into peptides. Tetrahedron Lett 2004. [DOI: 10.1016/j.tetlet.2003.11.117] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
50
|
Abstract
Over the past decade of proteome research peptide arrays have become a widespread and powerful tool to study molecular recognition events and to identify biologically active peptides. A variety of applications such as epitope mapping, characterisation of protein-protein interactions, enzyme-substrate or inhibitor interactions, and many more, have been published. Today's technologies for array production, inspired by DNA chips, have recently turned to the miniaturisation of peptide arrays. These advances open up an expanding spectrum of applications and the information obtained will be well-suited to developing substrates and inhibitors for diagnostic and therapeutic purposes.
Collapse
Affiliation(s)
- Ulf Reimer
- Jerini AG, Invalidenstrasse 130, D-10115 Berlin, Germany.
| | | | | |
Collapse
|