1
|
Bujda M, Klíma K. Enhancing Guided Bone Regeneration with a Novel Carp Collagen Scaffold: Principles and Applications. J Funct Biomater 2024; 15:150. [PMID: 38921524 PMCID: PMC11205119 DOI: 10.3390/jfb15060150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 05/21/2024] [Accepted: 05/29/2024] [Indexed: 06/27/2024] Open
Abstract
Bone defects resulting from trauma, surgery, and congenital, infectious, or oncological diseases are a functional and aesthetic burden for patients. Bone regeneration is a demanding procedure, involving a spectrum of molecular processes and requiring the use of various scaffolds and substances, often yielding an unsatisfactory result. Recently, the new collagen sponge and its structural derivatives manufactured from European carp (Cyprinus carpio) were introduced and patented. Due to its fish origin, the novel scaffold poses no risk of allergic reactions or transfer of zoonoses and additionally shows superior biocompatibility, mechanical stability, adjustable degradation rate, and porosity. In this review, we focus on the basic principles of bone regeneration and describe the characteristics of an "ideal" bone scaffold focusing on guided bone regeneration. Moreover, we suggest several possible applications of this novel material in bone regeneration processes, thus opening new horizons for further research.
Collapse
Affiliation(s)
- Michele Bujda
- Department of Oral and Maxillofacial Surgery, 1st Faculty of Medicine and General University Hospital in Prague, Charles University, 12108 Prague, Czech Republic
| | | |
Collapse
|
2
|
Pandele AM, Selaru A, Dinescu S, Costache M, Vasile E, Dascălu C, Raicopol MD, Teodorescu M. Synthesis and evaluation of poly(propylene fumarate)-grafted graphene oxide as nanofiller for porous scaffolds. J Mater Chem B 2023; 11:8241-8250. [PMID: 37565837 DOI: 10.1039/d3tb01232h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
In an effort to obtain porous scaffolds with improved mechanical properties and biocompatibility, the current study discusses nanocomposite materials based on poly(propylene fumarate)/N-vinyl pyrrolidone(PPF/NVP) networks reinforced with polymer-modified graphene oxide (GO@PPF). The GO@PPF nanofiller was synthesized through a facile and convenient surface esterification reaction, and the successful functionalization was demonstrated by complementary techniques such as FT-IR, XPS, TGA and TEM. The PPF/NVP/GO@PPF porous scaffolds obtained using NaCl as a porogen were further characterized in terms of morphology, mechanical properties, sol fraction, and in vitro degradability. SEM and nanoCT examinations of NaCl-leached samples revealed networks of interconnected pores, fairly uniform in size and shape. We show that the incorporation of GO@PPF in the polymer matrix leads to a significant enhancement in the mechanical properties, which we attribute to the formation of denser and more homogenous networks, as suggested by a decreased sol fraction for the scaffolds containing a higher amount of GO@PPF. Moreover, the surface of mineralized PPF/NVP/GO@PPG scaffolds is uniformly covered in hydroxyapatite-like crystals having a morphology and Ca/P ratio similar to bone tissue. Furthermore, the preliminary biocompatibility assessment revealed a good interaction between PPF/PVP/GO@PPF scaffolds and murine pre-osteoblasts in terms of cell viability and proliferation.
Collapse
Affiliation(s)
- Andreea M Pandele
- Advanced Polymer Materials Group, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061, Bucharest, Romania
- Department of Analytical Chemistry and Environmental Engineering, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061, Bucharest, Romania
| | - Aida Selaru
- Department of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095, Bucharest, Romania
| | - Sorina Dinescu
- Department of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095, Bucharest, Romania
| | - Marieta Costache
- Department of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095, Bucharest, Romania
| | - Eugeniu Vasile
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061, Bucharest, Romania
| | - Constanţa Dascălu
- Department of Physics, University Politehnica of Bucharest, 313 Splaiul Independenţei, 060042, Bucharest, Romania
| | - Matei D Raicopol
- "Costin Nenitzescu" Department of Organic Chemistry, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061, Bucharest, Romania.
| | - Mircea Teodorescu
- Department of Bioresources and Polymer Science, University Politehnica of Bucharest, 1-7 Gheorghe Polizu St., 011061, Bucharest, Romania
| |
Collapse
|
3
|
Moris H, Ghaee A, Karimi M, Nouri-Felekori M, Mashak A. Preparation and characterization of Pullulan-based nanocomposite scaffold incorporating Ag-Silica Janus particles for bone tissue engineering. BIOMATERIALS ADVANCES 2022; 135:212733. [PMID: 35929198 DOI: 10.1016/j.bioadv.2022.212733] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 02/12/2022] [Accepted: 02/21/2022] [Indexed: 06/15/2023]
Abstract
A nanocomposite bone scaffold was fabricated from pullulan, a natural extracellular polysaccharide. Pullulan (PULL) was blended with polyvinylpyrrolidone (PVP), and a nano-platform with ball-stick morphology, Ag-Silica Janus particles (Ag-Silica JPs), which were utilized to fabricate nanocomposite scaffold with enhanced mechanical and biological properties. The Ag-Silica JPs were synthesized via a one-step sol-gel method and used to obtain synergistic properties of silver and silica's antibacterial and bioactive effects, respectively. The synthesized Ag-Silica JPs were characterized by means of FE-SEM, DLS, and EDS. The PULL/PVP scaffolds containing Ag-Silica JPs, fabricated by the freeze-drying method, were evaluated by SEM, EDS, FTIR, XRD, ICP and biological analysis, including antibacterial activity, bioactivity, cell viability and cell culture tests. It was noted that increasing Ag-Silica JPs amounts to an optimum level (1% w/w) led to an improvement in compressive modulus and strength of nanocomposite scaffold, reaching 1.03 ± 0.48 MPa and 3.27 ± 0.18, respectively. Scaffolds incorporating Ag-Silica JPs also showed favorable antibacterial activity. The investigations through apatite forming ability of scaffolds in SBF indicated spherical apatite precipitates. Furthermore, the cell viability test proved the outstanding biocompatibility of nanocomposite scaffolds (more than 90%) confirmed by cell culture tests showing that increment of Ag-Silica JPs amounts led to better adhesion, proliferation, ALP activity and mineralization of MG-63 cells.
Collapse
Affiliation(s)
- Hanieh Moris
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, P.O. Box 14395-1561, Tehran, Iran
| | - Azadeh Ghaee
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, P.O. Box 14395-1561, Tehran, Iran.
| | - Majid Karimi
- Polymerization Engineering Department, Iran Polymer and Petrochemical Institute (IPPI), P.O. Box 14965/115, Tehran, Iran
| | - Mohammad Nouri-Felekori
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, P.O. Box 14395-1561, Tehran, Iran
| | - Arezou Mashak
- Department of Novel Drug Delivery Systems, Iran Polymer and Petrochemical Institute, PO Box: 14965/115, Tehran, Iran
| |
Collapse
|
4
|
Wang L, Chen B, Ji M, Guo D, He X, Lashari NUR, Fu C, Zheng J. Development and properties of
UV
‐cured poly (propylene fumarate)/hydroxyapatite composites coatings as potential application for bone adhesive tape. J Appl Polym Sci 2022. [DOI: 10.1002/app.52289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Liang Wang
- Xi’an Key Laboratory of Textile Composites, School of Materials Science and Engineering Xi'an Polytechnic University Xi'an China
- State Key Laboratory for Mechanical Behavior of Materials School of Materials Science and Engineering, Xi'an Jiaotong University Xi'an China
| | - Bing‐yu Chen
- Xi’an Key Laboratory of Textile Composites, School of Materials Science and Engineering Xi'an Polytechnic University Xi'an China
| | - Meng‐hao Ji
- Xi’an Key Laboratory of Textile Composites, School of Materials Science and Engineering Xi'an Polytechnic University Xi'an China
| | - Da‐gang Guo
- State Key Laboratory for Mechanical Behavior of Materials School of Materials Science and Engineering, Xi'an Jiaotong University Xi'an China
| | - Xin‐hai He
- Xi’an Key Laboratory of Textile Composites, School of Materials Science and Engineering Xi'an Polytechnic University Xi'an China
| | - Najeeb ur Rehman Lashari
- Xi’an Key Laboratory of Textile Composites, School of Materials Science and Engineering Xi'an Polytechnic University Xi'an China
| | - Chong Fu
- Xi’an Key Laboratory of Textile Composites, School of Materials Science and Engineering Xi'an Polytechnic University Xi'an China
| | - Jing Zheng
- Shaanxi Key Laboratory of Biomedical Metal Materials Northwest Institute for Non‐ferrous Metal Research Xi'an China
| |
Collapse
|
5
|
In vitro biocompatiability and mechanical properties of bone adhesive tape composite based on poly(butyl fumarate)/poly(propylene fumarate)-diacrylate networks. J Mech Behav Biomed Mater 2022; 126:105049. [PMID: 34991046 DOI: 10.1016/j.jmbbm.2021.105049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/09/2021] [Accepted: 12/13/2021] [Indexed: 11/24/2022]
Abstract
Polyfumarate has been considered as injectable and biodegradable bone cement. However, its mechanical and degradation properties are particularly important. Therefore, the current study aimed to develop the properties by compositing poly (butyl fumarate)-based networks with hydroxyapatite nano-powders. In this regard, the poly (butyl fumarate) (PBF) matrix composite was compared with different components by evaluating their composition, mechanical properties, hydrophilicity, and biodegradability. Furthermore, their bioactivity in the phosphate-buffered saline (PBS) and, via applying mouse embryo osteoblast precursor cells (MC3T3-E1), their cell interaction, including adhesion, proliferation, and in vitro cytotoxicity assay, were assessed. The addition of hydroxyapatite improved the mechanical strength and modulus of PBF matrix composite. The composite reinforced with 3 wt% hydroxyapatite showed a higher lap-shear strength (1.68 MPa) and bonding strength (4.30 MPa), a maximum compression strength at fracture (95.18 MPa), modulus (925.29 MPa), and compression strength at yield (31.43 MPa), respectively. Also, hydrophilicity and in vitro degradation of the composite were enhanced in the presence of hydroxyapatite. In this condition, after a period of immersion (52 weeks) in PBS, the weight loss rate, and degradation rate of the composite increased. The composite proliferation, adhesion, and toxicity of MC3T3-E1 cells improved in comparison to the PBF matrix composite. Accordingly, controllable strength and degradation of the composite, along with its proven biocompatibility, make the composite a candidate for the treatment of comminuted fractures.
Collapse
|
6
|
Three-Dimensional Printing of Hydroxyapatite Composites for Biomedical Application. CRYSTALS 2021. [DOI: 10.3390/cryst11040353] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Hydroxyapatite (HA) and HA-based nanocomposites have been recognized as ideal biomaterials in hard tissue engineering because of their compositional similarity to bioapatite. However, the traditional HA-based nanocomposites fabrication techniques still limit the utilization of HA in bone, cartilage, dental, applications, and other fields. In recent years, three-dimensional (3D) printing has been shown to provide a fast, precise, controllable, and scalable fabrication approach for the synthesis of HA-based scaffolds. This review therefore explores available 3D printing technologies for the preparation of porous HA-based nanocomposites. In the present review, different 3D printed HA-based scaffolds composited with natural polymers and/or synthetic polymers are discussed. Furthermore, the desired properties of HA-based composites via 3D printing such as porosity, mechanical properties, biodegradability, and antibacterial properties are extensively explored. Lastly, the applications and the next generation of HA-based nanocomposites for tissue engineering are discussed.
Collapse
|
7
|
Fabrication of a Porous Three-Dimensional Scaffold with Interconnected Flow Channels: Co-Cultured Liver Cells and In Vitro Hemocompatibility Assessment. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11062473] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The development of large-scale human liver scaffolds equipped with interconnected flow channels in three-dimensional space offers a promising strategy for the advancement of liver tissue engineering. Tissue-engineered scaffold must be blood-compatible to address the demand for clinical transplantable liver tissue. Here, we demonstrate the construction of 3-D macro scaffold with interconnected flow channels using the selective laser sintering (SLS) fabrication method. The accuracy of the printed flow channels was ensured by the incorporation of polyglycolic acid (PGA) microparticles as porogens over the conventional method of NaCl salt leaching. The fabricated scaffold was populated with Hep G2, followed by endothelization with endothelial cells (ECs) grown under perfusion of culture medium for up to 10 days. The EC covered scaffold was perfused with platelet-rich plasma for the assessment of hemocompatibility to examine its antiplatelet adhesion properties. Both Hep G2-covered scaffolds exhibited a markedly different albumin production, glucose metabolism and lactate production when compared to EC-Hep G2-covered scaffold. Most importantly, EC-Hep G2-covered scaffold retained the antiplatelet adhesion property associated with the perfusion of platelet-rich plasma through the construct. These results show the potential of fabricating a 3-D scaffold with interconnected flow channels, enabling the perfusion of whole blood and circumventing the limitation of blood compatibility for engineering transplantable liver tissue.
Collapse
|
8
|
Roushangar Zineh B, Shabgard MR, Roshangar L, Jahani K. Experimental and numerical study on the performance of printed alginate/hyaluronic acid/halloysite nanotube/polyvinylidene fluoride bio-scaffolds. J Biomech 2020; 104:109764. [PMID: 32247526 DOI: 10.1016/j.jbiomech.2020.109764] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 01/21/2020] [Accepted: 03/19/2020] [Indexed: 12/21/2022]
Abstract
The growing usage of printed bio scaffolds in the field of regenerative medicine has made this field very important in biomedical engineering. In this regard, three-dimensional printing (3D) technique needs bio-materials with higher mechanical and biological performance. The biomaterials with high mechanical performance beside its bio compatibility are limited. A novel bio-material made of Alginate, Hyaluronic acid, Halloysite Nanotube and Polyvinylidene Fluoride was used and characterized for printing cartilage bio scaffolds through numerical studies. CaCl2 was used for crosslinking of biomaterial. Scanning Electron Microscopy, mechanical tests (tensile and compressive test), MTT assay were conducted for evaluating this novel biomaterial. Different structures of bio material were simulated for numerical studies. The numerical study was performed in ANSYS 18 using three parameter Mooney-Rivlin model. According to experimental and numerical results, Halloysite Nanotube increases the tensile and compressive strength of biomaterial up to 47%. Results show that biomaterial have good mechanical performance due to mechanical forces required for cartilage bio scaffolds besides its high biological performance. Polyvinylidene fluoride reduces the mechanical performance while increasing the cell viability. MTT assay results performed on day 0, day 2 and day 6 show increase in cell number to be about twice for biomaterial containing 40 mg/ml alginate, 40 mg/ml halloysite nanotube, 10 mg/ml hyaluronic acid and 1 w/v Polyvinylidene fluoride. Numerical simulation shows high mechanical performance of bio material in different scaffolds structure. The best structure of bio scaffolds was achieved with 0.4 mm nozzle diameter and 0.4 space between rows.
Collapse
Affiliation(s)
| | | | - Leila Roshangar
- Stem Cells Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Kamal Jahani
- Mechanical Engineering Department, University of Tabriz, Iran
| |
Collapse
|
9
|
Christy PN, Basha SK, Kumari VS, Bashir A, Maaza M, Kaviyarasu K, Arasu MV, Al-Dhabi NA, Ignacimuthu S. Biopolymeric nanocomposite scaffolds for bone tissue engineering applications – A review. J Drug Deliv Sci Technol 2020. [DOI: 10.1016/j.jddst.2019.101452] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Kryou C, Leva V, Chatzipetrou M, Zergioti I. Bioprinting for Liver Transplantation. Bioengineering (Basel) 2019; 6:E95. [PMID: 31658719 PMCID: PMC6956058 DOI: 10.3390/bioengineering6040095] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 09/24/2019] [Accepted: 09/25/2019] [Indexed: 12/14/2022] Open
Abstract
Bioprinting techniques can be used for the in vitro fabrication of functional complex bio-structures. Thus, extensive research is being carried on the use of various techniques for the development of 3D cellular structures. This article focuses on direct writing techniques commonly used for the fabrication of cell structures. Three different types of bioprinting techniques are depicted: Laser-based bioprinting, ink-jet bioprinting and extrusion bioprinting. Further on, a special reference is made to the use of the bioprinting techniques for the fabrication of 2D and 3D liver model structures and liver on chip platforms. The field of liver tissue engineering has been rapidly developed, and a wide range of materials can be used for building novel functional liver structures. The focus on liver is due to its importance as one of the most critical organs on which to test new pharmaceuticals, as it is involved in many metabolic and detoxification processes, and the toxicity of the liver is often the cause of drug rejection.
Collapse
Affiliation(s)
- Christina Kryou
- Department of Physics, National Technical University of Athens, 15780 Zografou, Greece.
| | - Valentina Leva
- Department of Physics, National Technical University of Athens, 15780 Zografou, Greece.
| | | | - Ioanna Zergioti
- Department of Physics, National Technical University of Athens, 15780 Zografou, Greece.
| |
Collapse
|
11
|
Nettleton K, Luong D, Kleinfehn AP, Savariau L, Premanandan C, Becker ML. Molecular Mass-Dependent Resorption and Bone Regeneration of 3D Printed PPF Scaffolds in a Critical-Sized Rat Cranial Defect Model. Adv Healthc Mater 2019; 8:e1900646. [PMID: 31328402 DOI: 10.1002/adhm.201900646] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 07/10/2019] [Indexed: 11/11/2022]
Abstract
The emergence of additive manufacturing has afforded the ability to fabricate intricate, high resolution, and patient-specific polymeric implants. However, the availability of biocompatible resins with tunable resorption profiles remains a significant hurdle to clinical translation. In this study, 3D scaffolds are fabricated via stereolithographic cDLP printing of poly(propylene fumarate) (PPF) and assessed for bone regeneration in a rat critical-sized cranial defect model. Scaffolds are printed with two different molecular mass resin formulations (1000 and 1900 Da) with narrow molecular mass distributions and implanted to determine if these polymer characteristics influence scaffold resorption and bone regeneration in vivo. X-ray microcomputed tomography (µ-CT) data reveal that at 4 weeks the lower molecular mass polymer degrades faster than the higher molecular mass PPF and thus more new bone is able to infiltrate the defect. However, at 12 weeks, the regenerated bone volume of the 1900 Da formulation is nearly equivalent to the lower molecular mass 1000 Da formulation. Significantly, lamellar bone bridges the defect at 12 weeks with both PPF formulations and there is no indication of an acute inflammatory response.
Collapse
Affiliation(s)
- Karissa Nettleton
- Department of Polymer ScienceThe University of Akron Akron OH 44325 USA
| | - Derek Luong
- Department of Polymer ScienceThe University of Akron Akron OH 44325 USA
| | - Alex P. Kleinfehn
- Department of Polymer ScienceThe University of Akron Akron OH 44325 USA
| | - Laura Savariau
- Department of Polymer ScienceThe University of Akron Akron OH 44325 USA
| | - Christopher Premanandan
- Department of Veterinary BiosciencesCollege of Veterinary MedicineThe Ohio State University Columbus OH 43210 USA
| | - Matthew L. Becker
- Department of Polymer ScienceThe University of Akron Akron OH 44325 USA
- Departments of ChemistryMechanical Engineering and Material ScienceOrthopaedic SurgeryDuke University Durham NC 27708 USA
| |
Collapse
|
12
|
Cai Z, Wan Y, Becker ML, Long YZ, Dean D. Poly(propylene fumarate)-based materials: Synthesis, functionalization, properties, device fabrication and biomedical applications. Biomaterials 2019; 208:45-71. [PMID: 30991217 DOI: 10.1016/j.biomaterials.2019.03.038] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 03/04/2019] [Accepted: 03/23/2019] [Indexed: 12/22/2022]
Abstract
Poly(propylene fumarate) (PPF) is a biodegradable polymer that has been investigated extensively over the last three decades. It has led many scientists to synthesize and fabricate a variety of PPF-based materials for biomedical applications due to its controllable mechanical properties, tunable degradation and biocompatibility. This review provides a comprehensive overview of the progress made in improving PPF synthesis, resin formulation, crosslinking, device fabrication and post polymerization modification. Further, we highlight the influence of these parameters on biodegradation, biocompatibility, and their use in a number of regenerative medicine applications, especially bone tissue engineering. In particular, the use of 3D printing techniques for the fabrication of PPF-based scaffolds is extensively reviewed. The recent invention of a ring-opening polymerization method affords precise control of PPF molecular mass, molecular mass distribution (ƉM) and viscosity. Low ƉM facilitates time-certain resorption of 3D printed structures. Novel post-polymerization and post-printing functionalization methods have accelerated the expansion of biomedical applications that utilize PPF-based materials. Finally, we shed light on evolving uses of PPF-based materials for orthopedics/bone tissue engineering and other biomedical applications, including its use as a hydrogel for bioprinting.
Collapse
Affiliation(s)
- Zhongyu Cai
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117585, Singapore; Department of Chemistry, University of Pittsburgh, Chevron Science Center, 219 Parkman Avenue, Pittsburgh, PA 15260, United States.
| | - Yong Wan
- Collaborative Innovation Center for Nanomaterials, College of Physics, Qingdao University, No. 308 Ningxia Road, Qingdao, 266071, Shandong Province, China
| | - Matthew L Becker
- Department of Polymer Science, The University of Akron, Akron, OH 44325, United States
| | - Yun-Ze Long
- Collaborative Innovation Center for Nanomaterials, College of Physics, Qingdao University, No. 308 Ningxia Road, Qingdao, 266071, Shandong Province, China; Industrial Research Institute of Nonwovens & Technical Textiles, Qingdao University, No. 308 Ningxia Road, Qingdao, 266071, Shandong Province, China.
| | - David Dean
- Department of Plastic & Reconstructive Surgery, The Ohio State University, Columbus, OH 43210, United States.
| |
Collapse
|
13
|
Li J, Liu X, Park S, Miller AL, Terzic A, Lu L. Strontium-substituted hydroxyapatite stimulates osteogenesis on poly(propylene fumarate) nanocomposite scaffolds. J Biomed Mater Res A 2019; 107:631-642. [PMID: 30422387 PMCID: PMC7224963 DOI: 10.1002/jbm.a.36579] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 10/09/2018] [Accepted: 11/05/2018] [Indexed: 12/11/2022]
Abstract
Incorporation of hydroxyapatite (HA) into polymer networks is a promising strategy to enhance the mechanical properties and osteoinductivity of the composite scaffolds for bone tissue engineering. In this study, we designed a group of nanocomposite scaffolds based on cross-linkable poly(propylene fumarate) (PPF) and 30 wt % strontium-hydroxyapatite (Sr-HA) nanoparticles. Four different Sr contents [Sr:(Sr + Ca), molar ratio] in the Sr-HA particles were studied: 0% (HA), 5% (Sr5-HA), 10% (Sr10-HA), and 20% (Sr20-HA). Two-dimensional (2D) disks were prepared using a thermal crosslinking method. The structure and surface morphology of different Sr-HA and PPF/Sr-HA composites were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), and atomic force microscopy (AFM). To detect cellular responses in vitro, MC3T3-E1 cells were seeded and cultured on the different PPF/Sr-HA composite disks. Cell morphology after 24 h and 5 days were imaged using Live/Dead live cell staining and SEM, respectively. Cell proliferation was quantified using an MTS assay at 1, 4, and 7 days. Osteogenic differentiation of the cells was examined by alkaline phosphatase (ALP) staining at 10 days and quantified using ALP activity and osteocalcin assays at 7, 14, and 21 days. The sizes of the HA, Sr5-HA, Sr10-HA, and Sr20-HA particles were mainly between 10 × 20 nm and 10 × 250 nm, and these nanoparticles were dispersed or clustered in the composite scaffolds. in vitro cell studies showed that the PPF/Sr10-HA scaffold was significantly better than the other three groups (PPF/HA, PPF/Sr5-HA, and PPF/Sr20-HA) in supporting MC3T3-E1 cell adhesion, proliferation, and differentiation. PPF/Sr10-HA may, therefore, serve as a promising scaffold material for bone tissue engineering. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 631-642, 2019.
Collapse
Affiliation(s)
- Jingfeng Li
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota 55905, USA
- Department of Orthopedics, Zhongnan Hospital of Wuhan University, Wuhan, Hubei 430071, China
| | - Xifeng Liu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Sungjo Park
- Department of Cardiovascular Diseases and Center for Regenerative Medicine, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - A. Lee Miller
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Andre Terzic
- Department of Cardiovascular Diseases and Center for Regenerative Medicine, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota 55905, USA
| |
Collapse
|
14
|
Su L, Kong X, Lim S, Loo S, Tan S, Poh K, Dutton J, Stewart C, Cook S, Su X, Ma J, Zhang J, Ye L. The prostaglandin H2 analog U-46619 improves the differentiation efficiency of human induced pluripotent stem cells into endothelial cells by activating both p38MAPK and ERK1/2 signaling pathways. Stem Cell Res Ther 2018; 9:313. [PMID: 30442193 PMCID: PMC6238266 DOI: 10.1186/s13287-018-1061-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 10/22/2018] [Accepted: 10/24/2018] [Indexed: 12/11/2022] Open
Abstract
Background We have shown that the differentiation of human-induced pluripotent stem cells (hiPSCs) into endothelial cells (ECs) is more efficient when performed with a 3-dimensional (3D) scaffold of biomaterial than in monolayers. The current study aims to further increase hiPSC-EC differentiation efficiency by deciphering the signaling pathways in 3D scaffolds. Methods and results We modified our 3D protocol by using U-46619 to upregulate both p38 mitogen-activated protein kinase (p38MAPK) and extracellular signal-regulated kinase 1/2 (ERK1/2) signaling, which increased the differentiation efficiency (as measured by CD31 expression) to as high as 89% in two established hiPSC lines. The differentiated cells expressed arteriovenous, but not lymphatic, markers; formed tubular structures and EC lumen in vitro; had significantly shorter population-doubling times than monolayer-differentiated hiPSC-ECs; and restored perfusion and vascularity in a murine hind limb ischemia model. The differentiation efficiency was also > 85% in three hiPSC lines that had been derived from patients with diseases or disease symptoms that have been linked to endothelial dysfunction. Conclusions These observations demonstrate that activating both p38MAPK and ERK1/2 signaling pathways with U-46619 improves the efficiency of arteriovenous hiPSC-EC differentiation and produces cells with greater proliferative capacity. Electronic supplementary material The online version of this article (10.1186/s13287-018-1061-4) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Liping Su
- National Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, 117609, Singapore
| | - Xiaocen Kong
- Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China
| | - Szeyun Lim
- National Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, 117609, Singapore
| | - Szejie Loo
- National Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, 117609, Singapore
| | - Shihua Tan
- National Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, 117609, Singapore
| | - Kiankeong Poh
- Department of Cardiology, National University Health System Singapore and Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - James Dutton
- Stem cell Institute, University of Minnesota, Minneapolis, MN, USA
| | - Colin Stewart
- Institute of Medical Biology, A*STAR, Singapore, Singapore
| | - Stuart Cook
- National Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, 117609, Singapore.,Programme in Cardiovascular & Metabolic Disorders, Duke-National University of Singapore, Singapore, Singapore.,NHLI, Imperial College, London, UK
| | - Xiaofei Su
- Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China
| | - Jianhua Ma
- Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, 68 Changle Road, Nanjing, 210006, China.
| | - Jianyi Zhang
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, 35294-2182, USA.
| | - Lei Ye
- National Heart Research Institute of Singapore, National Heart Centre Singapore, Singapore, 117609, Singapore.
| |
Collapse
|
15
|
Wu W, Liu X, Zhou Z, Miller AL, Lu L. Three-dimensional porous poly(propylene fumarate)-co-poly(lactic-co-glycolic acid) scaffolds for tissue engineering. J Biomed Mater Res A 2018; 106:2507-2517. [PMID: 29707898 PMCID: PMC9933994 DOI: 10.1002/jbm.a.36446] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Revised: 04/13/2018] [Accepted: 04/25/2018] [Indexed: 12/25/2022]
Abstract
Three-dimensional structural scaffolds have played an important role in tissue engineering, especially broad applications in areas such as regenerative medicine. We have developed novel biodegradable porous poly(propylene fumarate)-co-poly(lactic-co-glycolic acid) (PPF-co-PLGA) scaffolds using thermally induced phase separation, and determined the effects of critical parameters such as copolymer concentration (6, 8, and 10 wt %) and the binary solvent ratio of dioxane:water (78/22, 80/20, 82/18 wt/wt %) on the fabrication process. The cloud-point temperatures of PPF-co-PLGA changed in parallel with increasing copolymer concentration, but inversely with increasing dioxane content. The compressive moduli of the scaffolds increased with greater weight composition and dioxane:water ratio. Scaffolds formed using high copolymer concentrations and solvent ratios exhibited preferable biomineralization. All samples showed biodegradation capability in both accelerated solution and phosphate-buffered saline (PBS). Cell toxicity testing indicated that the scaffolds had good biocompatibility with bone and nerve cells, which adhered well to the scaffolds. Variations in the copolymer concentration and solvent ratio exercised a remarkable influence on morphology, mechanical properties, biomineralization, and biodegradation, but not on the cell viability and adhesion of the cross-linked scaffolds. An 8 to 10 wt % solute concentration and 80/20 to 82/18 wt/wt dioxane:water ratio were the optimum parameters for scaffold fabrication. PPF-co-PLGA scaffolds thus possess several promising prospects for tissue engineering applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A:2507-2517, 2018.
Collapse
Affiliation(s)
- Wei Wu
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Xifeng Liu
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA
| | - Zifei Zhou
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Department of Orthopedic Surgery, Shanghai East Hospital, Tongji University, Shanghai, 200120, China
| | - A. Lee Miller
- Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, MN, 55905, USA,Corresponding Author: Lichun Lu, Ph.D, Professor of Biomedical Engineering and Orthopedics, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905 USA, Phone: (507)-284-2267, Fax: 507-284-5075,
| |
Collapse
|
16
|
Abstract
3D printing, an upcoming technology, has vast potential to transform conventional fabrication processes due to the numerous improvements it can offer to the current methods. To date, the employment of 3D printing technology has been examined for applications in the fields of engineering, manufacturing and biological sciences. In this study, we examined the potential of adopting 3D printing technology for a novel application, electrochemical DNA biosensing. Metal 3D printing was utilized to construct helical-shaped stainless steel electrodes which functioned as a transducing platform for the detection of DNA hybridization. The ability of electroactive methylene blue to intercalate into the double helix structure of double-stranded DNA was then exploited to monitor the DNA hybridization process, with its inherent reduction peak serving as an analytical signal. The designed biosensing approach was found to demonstrate superior selectivity against a non-complementary DNA target, with a detection range of 1-1000 nM.
Collapse
Affiliation(s)
- Adeline Huiling Loo
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore.
| | - Chun Kiang Chua
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore.
| | - Martin Pumera
- Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore.
| |
Collapse
|
17
|
Kelly CN, Miller AT, Hollister SJ, Guldberg RE, Gall K. Design and Structure-Function Characterization of 3D Printed Synthetic Porous Biomaterials for Tissue Engineering. Adv Healthc Mater 2018; 7:e1701095. [PMID: 29280325 DOI: 10.1002/adhm.201701095] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 10/19/2017] [Indexed: 12/18/2022]
Abstract
3D printing is now adopted for use in a variety of industries and functions. In biomedical engineering, 3D printing has prevailed over more traditional manufacturing methods in tissue engineering due to its high degree of control over both macro- and microarchitecture of porous tissue scaffolds. However, with the improved flexibility in design come new challenges in characterizing the structure-function relationships between various architectures and both mechanical and biological properties in an assortment of clinical applications. Presently, the field of tissue engineering lacks a comprehensive body of literature that is capable of drawing meaningful relationships between the designed structure and resulting function of 3D printed porous biomaterial scaffolds. This work first discusses the role of design on 3D printed porous scaffold function and then reviews characterization of these structure-function relationships for 3D printed synthetic metallic, polymeric, and ceramic biomaterials.
Collapse
Affiliation(s)
- Cambre N. Kelly
- Department of Mechanical Engineering and Materials Science; Duke University; Box 90300 Hudson Hall Durham NC 27708 USA
| | - Andrew T. Miller
- Department of Mechanical Engineering and Materials Science; Duke University; Box 90300 Hudson Hall Durham NC 27708 USA
| | - Scott J. Hollister
- Coulter Department of Biomedical Engineering; Georgia Institute of Technology; 313 Ferst Drive, Room 2127 Atlanta GA 30332 USA
| | - Robert E. Guldberg
- Parker H. Petit Institute for Bioengineering and Bioscience; Georgia Institute of Technology; 315 Ferst Drive Atlanta GA 30332 USA
| | - Ken Gall
- Department of Mechanical Engineering and Materials Science; Duke University; Box 90300 Hudson Hall Durham NC 27708 USA
| |
Collapse
|
18
|
Yang C, Venton BJ. High Performance, Low Cost Carbon Nanotube Yarn based 3D Printed Electrodes Compatible with a Conventional Screen Printed Electrode System. ... IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS : PROCEEDINGS. IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS 2017; 2017:100-105. [PMID: 28890951 PMCID: PMC5589149 DOI: 10.1109/memea.2017.7985857] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
3D printing technology has been widely used as a rapid prototyping fabrication tool in several fields, including electrochemistry. In this work, we incorporate 3D printing technology with carbon nanotube yarns for electrochemical sensing of dopamine in the presence of ascorbic acid and uric acid. The novel 3D printed electrode provides a circular concavity detection zone with grooves to insert three electrodes. The electrode connections are fully compatible with conventional screen printed electrode workstation setups. The CNT yarn 3D printed electrode showed excellent electrocatalytic activity for the redox reaction of dopamine (DA) in the presence of ascorbic acid (AA) and uric acid (UA). Three well-defined sharp and fully resolved anodic peaks were found with the peak potentials using cyclic voltammetry (CV) at 50 mV, 305 mV, and 545 mV for AA, DA, and UA respectively and using differential pulse voltammetry (DPV) at 91 mV, 389 mV, and 569 mV, respectively. DA detection limit was 0.87 ± 0.09 μM. The CNT yarn 3D printed electrode displayed high reproducibility and stability. The electrode design enables the study of electrode reactions at the sidewall of CNTs, which cannot be performed using electrodes made by conventional fabrication methods. The new fabrication method provides a new platform to prototype new electrode materials for electrochemistry, providing a low-cost, customizable design compatible existing screen printed electrodes technology.
Collapse
Affiliation(s)
- Cheng Yang
- Department of Chemistry, University of Virginia, McCormick Road, Box 400319, Charlottesville, Virginia 22904-4319, United States
| | - B Jill Venton
- Department of Chemistry, University of Virginia, McCormick Road, Box 400319, Charlottesville, Virginia 22904-4319, United States
| |
Collapse
|
19
|
Trachtenberg JE, Placone JK, Smith BT, Fisher JP, Mikos AG. Extrusion-based 3D printing of poly(propylene fumarate) scaffolds with hydroxyapatite gradients. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2017; 28:532-554. [PMID: 28125380 PMCID: PMC5597446 DOI: 10.1080/09205063.2017.1286184] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 01/20/2017] [Indexed: 12/30/2022]
Abstract
The primary focus of this work is to present the current challenges of printing scaffolds with concentration gradients of nanoparticles with an aim to improve the processing of these scaffolds. Furthermore, we address how print fidelity is related to material composition and emphasize the importance of considering this relationship when developing complex scaffolds for bone implants. The ability to create complex tissues is becoming increasingly relevant in the tissue engineering community. For bone tissue engineering applications, this work demonstrates the ability to use extrusion-based printing techniques to control the spatial deposition of hydroxyapatite (HA) nanoparticles in a 3D composite scaffold. In doing so, we combined the benefits of synthetic, degradable polymers, such as poly(propylene fumarate) (PPF), with osteoconductive HA nanoparticles that provide robust compressive mechanical properties. Furthermore, the final 3D printed scaffolds consisted of well-defined layers with interconnected pores, two critical features for a successful bone implant. To demonstrate a controlled gradient of HA, thermogravimetric analysis was carried out to quantify HA on a per-layer basis. Moreover, we non-destructively evaluated the tendency of HA particles to aggregate within PPF using micro-computed tomography (μCT). This work provides insight for proper fabrication and characterization of composite scaffolds containing particle gradients and has broad applicability for future efforts in fabricating complex scaffolds for tissue engineering applications.
Collapse
Key Words
- (Tukey’s) Honestly Significant Difference test, HSD
- Analysis of variance, ANOVA
- Atomic force microscopy, AFM
- Diethyl fumarate, DEF
- Dimethyl sulfoxide, DMSO
- Extracellular matrix, ECM
- Fourier transform-infrared spectroscopy, FT-IR
- Hydroxyapatite, HA
- Micro-computed tomography, μCT.
- Phenylbis(246-trimethylbenzoyl)-phosphine oxide, BAPO
- Poly(propylene fumarate), PPF
- Poly(propylene fumarate)-co-poly(ε-caprolactone), PPF-co-PCL
- Polydispersity index, PDI
- Scanning electron microscopy, SEM
- Sodium dodecyl sulfate, SDS
- Stereolithography, STL
- Thermogravimetric analysis, TGA
- Viscosity
- bone tissue engineering
- composites
- compressive modulus
- gradient
Collapse
Affiliation(s)
| | - Jesse K. Placone
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | | | - John P. Fisher
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | | |
Collapse
|
20
|
Guo J, Liu X, Lee Miller A, Waletzki BE, Yaszemski MJ, Lu L. Novel porous poly(propylene fumarate-co-caprolactone) scaffolds fabricated by thermally induced phase separation. J Biomed Mater Res A 2016; 105:226-235. [PMID: 27513282 DOI: 10.1002/jbm.a.35862] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 08/03/2016] [Accepted: 08/08/2016] [Indexed: 11/12/2022]
Abstract
Scaffolds with porous structures are highly applicable for tissue engineering and regenerative medicine. In the present study, 3-dimensional poly(propylene fumarate-co-caprolactone) [P(PF-co-CL)] scaffolds were fabricated from a P(PF-co-CL)-dioxane-water ternary system through thermally induced phase separation (TIPS). Cloud points of P(PF-co-CL) in dioxane-water solutions increased with increased solute concentration, but increased dioxane composition decreased cloud point. Among 3 polymer concentrations (4, 8, and 12 wt%), 8 wt% P(PF-co-CL) scaffolds exhibited the best pore interconnectivity, with large, regular sized pores. Scaffolds were formed in 3 solutions with different dioxane-water ratios (74/26, 78/22, and 82/18 wt/wt); the 78/22 wt/wt scaffold had finger-shaped patterns with better interconnectivity than scaffolds from the other two ratios. Higher dioxane-water ratios resulted in a larger contact angle and thus less wettability for the fabricated scaffold, while scaffolds fabricated from higher concentrations of P(PF-co-CL) or high dioxane-water ratios had better biomineralization after soaking in simulated body fluid. In vitro cell viability testing showed the scaffolds had good biocompatibility with both bone and nerve cells. The results indicate that the polymer concentration and solvents ratio significantly affect the formation of porous structures, and optimum processing parameters were found to be 8% polymer concentration and 22% to 24% water content. These porous P(PF-co-CL) scaffolds fabricated via TIPS may be useful in various tissue engineering applications © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 226-235, 2017.
Collapse
Affiliation(s)
- Ji Guo
- Department of Physiology and Biomedical Engineering and Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, 55905.,Department of Orthopedic Surgery, Huashan Hospital, Fudan University, Shanghai, 200000, China
| | - Xifeng Liu
- Department of Physiology and Biomedical Engineering and Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, 55905
| | - A Lee Miller
- Department of Physiology and Biomedical Engineering and Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, 55905
| | - Brian E Waletzki
- Department of Physiology and Biomedical Engineering and Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, 55905
| | - Michael J Yaszemski
- Department of Physiology and Biomedical Engineering and Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, 55905
| | - Lichun Lu
- Department of Physiology and Biomedical Engineering and Department of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, Minnesota, 55905
| |
Collapse
|
21
|
Castagna R, Tunesi M, Saglio B, Della Pina C, Sironi A, Albani D, Bertarelli C, Falletta E. Ultrathin electrospun PANI nanofibers for neuronal tissue engineering. J Appl Polym Sci 2016. [DOI: 10.1002/app.43885] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- R. Castagna
- Dipartimento Di Chimica, Materiali E Ingegneria Chimica “G. Natta,”; Politecnico Di Milano; Piazza L. Da Vinci 32 Milano 20133 Italy
- Italian Interuniversity Consortium on Material Science and Technology; INSTM, UdR Milano Politecnico; via G. Giusti 9 Firenze 50121 Italy
| | - M. Tunesi
- Dipartimento Di Chimica, Materiali E Ingegneria Chimica “G. Natta,”; Politecnico Di Milano; Piazza L. Da Vinci 32 Milano 20133 Italy
- Italian Interuniversity Consortium on Material Science and Technology; INSTM, UdR Milano Politecnico; via G. Giusti 9 Firenze 50121 Italy
| | - B. Saglio
- Dipartimento Di Chimica, Materiali E Ingegneria Chimica “G. Natta,”; Politecnico Di Milano; Piazza L. Da Vinci 32 Milano 20133 Italy
- Center for Nano Science and Technology @PoliMi; Istituto Italiano Di Tecnologia; via Pascoli 70/3 Milano 20133 Italy
| | - C. Della Pina
- Dipartimento Di Chimica; Università Degli Studi Di Milano; CNR-ISTM, via Golgi 19 Milano 20133 Italy
| | - A. Sironi
- Dipartimento Di Chimica; Università Degli Studi Di Milano; CNR-ISTM, via Golgi 19 Milano 20133 Italy
| | - D. Albani
- Department of Neuroscience; IRCCS-Istituto Di Ricerche Farmacologiche “Mario Negri,”; via La Masa 19 Milan 20156 Italy
| | - C. Bertarelli
- Dipartimento Di Chimica, Materiali E Ingegneria Chimica “G. Natta,”; Politecnico Di Milano; Piazza L. Da Vinci 32 Milano 20133 Italy
- Italian Interuniversity Consortium on Material Science and Technology; INSTM, UdR Milano Politecnico; via G. Giusti 9 Firenze 50121 Italy
| | - E. Falletta
- Dipartimento Di Chimica; Università Degli Studi Di Milano; CNR-ISTM, via Golgi 19 Milano 20133 Italy
| |
Collapse
|
22
|
Wang JZ, Zhu YX, Ma HC, Chen SN, Chao JY, Ruan WD, Wang D, Du FG, Meng YZ. Developing multi-cellular tumor spheroid model (MCTS) in the chitosan/collagen/alginate (CCA) fibrous scaffold for anticancer drug screening. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 62:215-25. [DOI: 10.1016/j.msec.2016.01.045] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Revised: 12/23/2015] [Accepted: 01/19/2016] [Indexed: 01/17/2023]
|
23
|
Suchý T, Šupová M, Sauerová P, Verdánová M, Sucharda Z, Rýglová Š, Žaloudková M, Sedláček R, Kalbáčová MH. The effects of different cross-linking conditions on collagen-based nanocomposite scaffolds-an in vitro evaluation using mesenchymal stem cells. ACTA ACUST UNITED AC 2015; 10:065008. [PMID: 26586611 DOI: 10.1088/1748-6041/10/6/065008] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Nanocomposite scaffolds which aimed to imitate a bone extracellular matrix were prepared for bone surgery applications. The scaffolds consisted of polylactide electrospun nano/sub-micron fibres, a natural collagen matrix supplemented with sodium hyaluronate and natural calcium phosphate nano-particles (bioapatite). The mechanical properties of the scaffolds were improved by means of three different cross-linking agents: N-(3-dimethylamino propyl)-N'-ethylcarbodiimide hydrochloride and N-hydroxysuccinimide in an ethanol solution (EDC/NHS/EtOH), EDC/NHS in a phosphate buffer saline solution (EDC/NHS/PBS) and genipin. The effect of the various cross-linking conditions on the pore size, structure and mechanical properties of the scaffolds were subsequently studied. In addition, the mass loss, the swelling ratio and the pH of the scaffolds were determined following their immersion in a cell culture medium. Furthermore, the metabolic activity of human mesenchymal stem cells (hMSCs) cultivated in scaffold infusions for 2 and 7 days was assessed. Finally, studies were conducted of cell adhesion, proliferation and penetration into the scaffolds. With regard to the structural stability of the tested scaffolds, it was determined that EDC/NHS/PBS and genipin formed the most effectively cross-linked materials. Moreover, it was discovered that the genipin cross-linked scaffold also provided the best conditions for hMSC cultivation. In addition, the infusions from all the scaffolds were found to be non-cytotoxic. Thus, the genipin and EDC/NHS/PBS cross-linked scaffolds can be considered to be promising biomaterials for further in vivo testing and bone surgery applications.
Collapse
Affiliation(s)
- Tomáš Suchý
- Department of Composites and Carbon Materials, Institute of Rock Structure and Mechanics, Academy of Sciences of the Czech Republic, V Holesovickach 41, Prague 8, 182 09, Czech Republic. Laboratory of Biomechanics, Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, Prague 6, 166 07, Czech Republic
| | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Del Rosario C, Rodríguez-Évora M, Reyes R, Delgado A, Évora C. BMP-2, PDGF-BB, and bone marrow mesenchymal cells in a macroporous β-TCP scaffold for critical-size bone defect repair in rats. ACTA ACUST UNITED AC 2015. [PMID: 26201844 DOI: 10.1088/1748-6041/10/4/045008] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The aim of this work was to study the bone repair induced by bone morphogenetic protein-2 (BMP-2), rat mesenchymal stem cells (rMSCs), and platelet-derived growth factor (PDGF-BB) incorporated in a macroporous beta-tricalcium phosphate (β-TCP) system fabricated by robocasting, and to identify the most beneficial combination in a critical rat calvaria defect. BMP-2 was formulated in microspheres to provide a prolonged, local concentration, whereas PDGF-BB, which acts during the initial stage of defect repair, was incorporated in a thin layer of crosslinked alginate. Approximately 80% of PDGF-BB and 90% of BMP-2 were released into the defect during the first 2 d and 3 weeks, respectively. Histological analyses indicated a minor synergistic effect in the BMP-2-MSC groups. In contrast, significant antagonism was found with combined BMP-2 and PDGF-BB defect treatment. The high-grade repair induced by BMP-2 rules out any advantage from combining BMP-2 with PDGF-BB or MSCs, at least with this scaffold and defect model.
Collapse
Affiliation(s)
- Carlos Del Rosario
- Department of Chemical Engineering and Pharmaceutical Technology, University of La Laguna, 38200 La Laguna, Spain
| | | | | | | | | |
Collapse
|
25
|
Dadsetan M, Guda T, Runge MB, Mijares D, LeGeros RZ, LeGeros JP, Silliman DT, Lu L, Wenke JC, Brown Baer PR, Yaszemski MJ. Effect of calcium phosphate coating and rhBMP-2 on bone regeneration in rabbit calvaria using poly(propylene fumarate) scaffolds. Acta Biomater 2015; 18:9-20. [PMID: 25575855 DOI: 10.1016/j.actbio.2014.12.024] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 12/09/2014] [Accepted: 12/24/2014] [Indexed: 10/24/2022]
Abstract
Various calcium phosphate based coatings have been evaluated for better bony integration of metallic implants and are currently being investigated to improve the surface bioactivity of polymeric scaffolds. The aim of this study was to evaluate the role of calcium phosphate coating and simultaneous delivery of recombinant human bone morphogenetic protein-2 (rhBMP-2) on the in vivo bone regeneration capacity of biodegradable, porous poly(propylene fumarate) (PPF) scaffolds. PPF scaffolds were coated with three different calcium phosphate formulations: magnesium-substituted β-tricalcium phosphate (β-TCMP), carbonated hydroxyapatite (synthetic bone mineral, SBM) and biphasic calcium phosphate (BCP). In vivo bone regeneration was evaluated by implantation of scaffolds in a critical-sized rabbit calvarial defect loaded with different doses of rhBMP-2. Our data demonstrated that scaffolds with each of the calcium phosphate coatings were capable of sustaining rhBMP-2 release and retained an open porous structure. After 6weeks of implantation, micro-computed tomography revealed that the rhBMP-2 dose had a significant effect on bone formation within the scaffolds and that the SBM-coated scaffolds regenerated significantly greater bone than BCP-coated scaffolds. Mechanical testing of the defects also indicated restoration of strength in the SBM and β-TCMP with rhBMP-2 delivery. Histology results demonstrated bone growth immediately adjacent to the scaffold surface, indicating good osteointegration and osteoconductivity for coated scaffolds. The results obtained in this study suggest that the coated scaffold platform demonstrated a synergistic effect between calcium phosphate coatings and rhBMP-2 delivery and may provide a promising platform for the functional restoration of large bone defects.
Collapse
|
26
|
Gao Q, Hu B, Ning Q, Ye C, Xie J, Ye J, Gao C. A primary study of poly(propylene fumarate)-2-hydroxyethyl methacrylate copolymer scaffolds for tarsal plate repair and reconstruction in rabbit eyelids. J Mater Chem B 2015; 3:4052-4062. [PMID: 32262627 DOI: 10.1039/c5tb00285k] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Eyelid reconstruction includes anterior lamella reconstruction and posterior lamella reconstruction. As an important skeletal component of the posterior lamella, tarsal plates repair is the key issue for eyelid reconstruction. Presently, neither traditional surgery nor autograft/allograft has achieved satisfactory repair effects. Poly(propylene fumarate)-co-2-hydroxyethyl methacrylate (PPF-HEMA) networks with mass ratios of 1 : 0.5, 1 : 1 and 1 : 2 were synthesized and used as the tarsal substitute in this study. Their chemical compositions, swelling ability, and mechanical properties were characterized. Porous scaffolds were fabricated by a gelatin particle leaching method. The in vitro studies of cytotoxicity on human dermal fibroblasts (HDFs) and degradation demonstrated that PPF-HEMA scaffolds did not have noticeable cell cytotoxicity and their degradation rates correlated with the ratio of PPF to HEMA. The PPF-HEMA networks, with mass ratios of 1 : 1 and 1 : 2, and an ADM control were implanted in rabbits with tarsal plate defects for in vivo biocompatibility and degradation behavior evaluation. PPF-HEMA scaffolds provided satisfactory repair results with mild tissue response and biocompatibility to fibroblast growth and fibrous capsulation compared to the ADM control. The tissue compatible and biodegradable PPF-HEMA networks with elastic mechanical properties were proven to be a suitable candidate for tarsal repair.
Collapse
Affiliation(s)
- Qi Gao
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University, College of Medicine, Hangzhou, Zhejiang 310009, China.
| | | | | | | | | | | | | |
Collapse
|
27
|
Romanelli SM, Fath KR, Phekoo AP, Knoll GA, Banerjee IA. Layer-by-layer assembly of peptide based bioorganic-inorganic hybrid scaffolds and their interactions with osteoblastic MC3T3-E1 cells. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 51:316-28. [PMID: 25842141 DOI: 10.1016/j.msec.2015.03.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Revised: 01/30/2015] [Accepted: 03/13/2015] [Indexed: 12/16/2022]
Abstract
In this work we have developed a new family of biocomposite scaffolds for bone tissue regeneration by utilizing self-assembled fluorenylmethyloxycarbonyl protected Valyl-cetylamide (FVC) nanoassemblies as templates. To tailor the assemblies for enhanced osteoblast attachment and proliferation, we incorporated (a) Type I collagen, (b) a hydroxyapatite binding peptide sequence (EDPHNEVDGDK) derived from dentin sialophosphoprotein and (c) the osteoinductive bone morphogenetic protein-4 (BMP-4) to the templates by layer-by-layer assembly. The assemblies were then incubated with hydroxyapatite nanocrystals blended with varying mass percentages of TiO2 nanoparticles and coated with alginate to form three dimensional scaffolds for potential applications in bone tissue regeneration. The morphology was examined by TEM and SEM and the binding interactions were probed by FITR spectroscopy. The scaffolds were found to be non-cytotoxic, adhered to mouse preosteoblast MC3T3-E1 cells and promoted osteogenic differentiation as indicated by the results obtained by alkaline phosphatase assay. Furthermore, they were found to be biodegradable and possessed inherent antibacterial capability. Thus, we have developed a new family of tissue-engineered biocomposite scaffolds with potential applications in bone regeneration.
Collapse
Affiliation(s)
- Steven M Romanelli
- Fordham University Department of Chemistry, 441 East Fordham Road, Bronx, NY 10458, United States
| | - Karl R Fath
- The City University of New York, Queens College, Department of Biology, 65-30 Kissena Blvd, Flushing, NY 11367, United States; The Graduate Center, The City University of New York, 365 Fifth Avenue, NY 10016, United States
| | - Aruna P Phekoo
- The City University of New York, Queens College, Department of Biology, 65-30 Kissena Blvd, Flushing, NY 11367, United States
| | - Grant A Knoll
- Fordham University Department of Chemistry, 441 East Fordham Road, Bronx, NY 10458, United States
| | - Ipsita A Banerjee
- Fordham University Department of Chemistry, 441 East Fordham Road, Bronx, NY 10458, United States.
| |
Collapse
|
28
|
Saito E, Suarez-Gonzalez D, Murphy WL, Hollister SJ. Biomineral coating increases bone formation by ex vivo BMP-7 gene therapy in rapid prototyped poly(L-lactic acid) (PLLA) and poly(ε-caprolactone) (PCL) porous scaffolds. Adv Healthc Mater 2015; 4:621-32. [PMID: 25515846 DOI: 10.1002/adhm.201400424] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Indexed: 11/12/2022]
Abstract
Porousbiodegradable polymer scaffolds are widely utilized for bone tissue engineering, but are not osteoconductive like calcium phosphate scaffolds. We combine indirect solid freeform fabrication (SFF), ex vivo gene therapy, with biomineral coating to compare the effect of biomineral coating on bone regeneration for Poly (L-lactic acid) (PLLA) and Poly (ε-caprolactone) (PCL) scaffolds with the same porous architecture. Scanning electron microscope (SEM) and micro-computed tomography (μ-CT) demonstrate PLLA and PCL scaffolds have the same porous architecture and are completely coated. All scaffolds are seeded with human gingival fibroblasts (HGF) transduced with adenovirus encoded with either bone morphogenetic protein 7 (BMP-7) or green fluorescent protein (GFP), and implanted into mice subcutaneously for 3 and 10 weeks. Only scaffolds with BMP-7 transduced HGFs show mineralized tissue formation. At 3 weeks some blood vessel-like structures are observed in coated PLLA and PCL scaffolds, but there is no significant difference in bone ingrowth between the coated and uncoated scaffolds for either PLLA or PCL. At 10 weeks, however, coated scaffolds (both PLLA and PCL) have significantly more bone ingrowth than uncoated scaffolds, which have more fibrous tissue. Coated PLLA scaffolds have improved mechanical properties compared with uncoated PLLA scaffolds due to increased bone ingrowth.
Collapse
Affiliation(s)
- Eiji Saito
- Department of Biomedical Engineering; 1101 Beal Ave. University of Michigan; Ann Arbor MI 48109-2099 USA
| | | | - William L. Murphy
- Materials Science Program; University of Wisconsin; Madison WI 53706 USA
- Department of Biomedical Engineering; University of Wisconsin; Madison WI 53706 USA
- Department of Orthopedics and Rehabilitation; University of Wisconsin; Madison WI 53706 USA
| | - Scott J. Hollister
- Department of Biomedical Engineering; 1101 Beal Ave. University of Michigan; Ann Arbor MI 48109-2099 USA
- Department of Mechanical Engineering; University of Michigan; Ann Arbor MI 48109-2125 USA
- Department of Surgery; University of Michigan; Ann Arbor MI 48109-032 USA
| |
Collapse
|
29
|
Henry MG, Cai L, Liu X, Zhang L, Dong J, Chen L, Wang Z, Wang S. Roles of hydroxyapatite allocation and microgroove dimension in promoting preosteoblastic cell functions on photocured polymer nanocomposites through nuclear distribution and alignment. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2015; 31:2851-60. [PMID: 25710252 DOI: 10.1021/la504994e] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This study clarifies how hydroxyapatite (HA) allocation and microgroove dimension affect mouse preosteoblastic MC3T3-E1 cell functions on microgrooved substrates of polymer nanocomposites. Using replica molding from micromachined silicon wafer templates, we fabricated photocured poly(ε-caprolactone) triacrylate (PCLTA)/HA nanocomposite substrates with parallel microgrooves (two groove widths of 5 and 15 μm and one groove depth of 5 μm). Four types of microgrooved substrates were made: "homogeneous" ones of PCLTA and PCLTA/HA with uniform distribution and two "heterogeneous" laminated microgrooved substrates with HA only in the PCLTA matrix in the ridges or bottom. These substrates were used to regulate MC3T3-E1 cell attachment, proliferation, alignment, nuclear circularity and distribution, and mineralization. MC3T3-E1 cell attachment and proliferation were much higher on the microgrooved substrates of PCLTA/HA than on those of PCLTA, in particular, on the 5 μm wide microgrooved substrate with PCLTA/HA ridges and PCLTA bottom. The shape and distribution of MC3T3-E1 cytoskeleton and nuclei were altered by the substrate topography and HA allocation. For 5 μm wide heterogeneous microgrooved substrates with HA only in the ridges, MC3T3-E1 cells exhibited better spreading perpendicular to the microgrooves but tended to extend along the microgrooves containing HA in the bottom. The widest cells and the roundest/largest cell nuclei were observed on the heterogeneous substrate with PCLTA/HA ridges, while the narrowest cells with the best elongation were found on the homogeneous PCLTA/HA substrate. The trend in MC3T3-E1 cell mineralization on the substrates was consistent with that in cell/nuclear elongation. Osteocalcin mRNA expression was significantly higher on the PCLTA/HA substrates than on the PCLTA ones and also on the microgrooved substrates of PCLTA/HA than on the flat ones, regardless of the groove width of 5 or 15 μm.
Collapse
Affiliation(s)
- Michael G Henry
- Department of Materials Science and Engineering, The University of Tennessee , Knoxville, Tennessee 37996, United States
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Thomas AM, Shea LD. Cryotemplation for the Rapid Fabrication of Porous, Patternable Photopolymerized Hydrogels. J Mater Chem B 2014; 2:4521-4530. [PMID: 25083293 PMCID: PMC4112475 DOI: 10.1039/c4tb00585f] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Aline M Thomas
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois
| | - Lonnie D Shea
- Department of Chemical and Biological Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA ; Institute for BioNanotechnology in Medicine (IBNAM), Northwestern University, Chicago, IL, USA ; Center for Reproductive Science (CRS), Northwestern University, Evanston, IL, USA ; Robert H. Lurie Comprehensive Cancer Center, Northwestern University, Chicago, IL, USA ; Chemistry of Life Processes Institute (CLP), Northwestern University, Evanston, IL, USA
| |
Collapse
|
31
|
Wu L, Lin L, Qin YX. Enhancement of cell ingrowth, proliferation, and early differentiation in a three-dimensional silicon carbide scaffold using low-intensity pulsed ultrasound. Tissue Eng Part A 2014; 21:53-61. [PMID: 24935158 DOI: 10.1089/ten.tea.2013.0597] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Concerns over the use of autografts or allografts have necessitated the development of biomaterials for bone regeneration. Various studies have been performed to optimize the cultivation of osteogenic cells using osteoconductive porous scaffolds. The aim of this study was to evaluate the osteogenic efficiency of bone cell ingrowth, proliferation, and early differentiation in a silicon carbide (SiC) porous ceramic scaffold promoted with low-intensity pulsed ultrasound. MC3T3-E1 mouse preosteoblasts were seeded onto scaffolds and cultured for 4 and 7 days with daily of 20-min ultrasound treatment. The cells were evaluated for cell attachment, morphology, viability, ingrowth depth, volumetric proliferation, and early differentiation. After 4 and 7 days of culture and ultrasound exposure, the cell density was higher in the ultrasound-treated group compared with the sham-treated group on SiC scaffolds. The cell ingrowth depths inside the SiC scaffolds were 149.2±27.3 μm at 1 day, 310.1±12.6 μm for the ultrasound-treated group and 248.0±19.7 μm for the sham control at 4 days, and 359.6±18.5 μm for the ultrasound-treated group and 280.0±17.7 μm for the sham control at 7 days. They were significantly increased, that is, 25% (p=0.0029) and 28% (p=0.0008) increase, respectively, with ultrasound radiation force as compared with those in sham control at 4 and 7 days postseeding. The dsDNA contents were 583.5±19.1 ng/scaffold at 1 day, 2749.9±99.9 ng/scaffold for the ultrasound-treated group and 2514.9±114.7 ng/scaffold for the sham control at 4 days, and 3582.3±325.3 ng/scaffold for the ultrasound-treated group and 2825.7±134.3 ng/scaffold for the sham control at 7 days. There was a significant difference in the dsDNA content between the ultrasound- and sham-treated groups at 4 and 7 days. The ultrasound-treated group with the SiC construct showed a 9% (p=0.00029) and 27% (p=0.00017) increase in the average dsDNA content at 4 and 7 days over the sham control group, respectively. Alkaline phosphatase activity was significantly increased by the treatment of ultrasound at 4 (p=0.012) and 7 days (p=0.035). These results suggested that ultrasound treatment with low-intensity acoustic energy facilitated the cellular ingrowth and enhanced the proliferation and early differentiation of osteoblasts in SiC scaffolds.
Collapse
Affiliation(s)
- Lin Wu
- 1 Department of Prosthodontics, School of Stomatology, China Medical University , Shenyang, People's Republic of China
| | | | | |
Collapse
|
32
|
Giannitelli SM, Accoto D, Trombetta M, Rainer A. Current trends in the design of scaffolds for computer-aided tissue engineering. Acta Biomater 2014; 10:580-94. [PMID: 24184176 DOI: 10.1016/j.actbio.2013.10.024] [Citation(s) in RCA: 206] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2013] [Revised: 09/28/2013] [Accepted: 10/22/2013] [Indexed: 02/07/2023]
Abstract
Advances introduced by additive manufacturing have significantly improved the ability to tailor scaffold architecture, enhancing the control over microstructural features. This has led to a growing interest in the development of innovative scaffold designs, as testified by the increasing amount of research activities devoted to the understanding of the correlation between topological features of scaffolds and their resulting properties, in order to find architectures capable of optimal trade-off between often conflicting requirements (such as biological and mechanical ones). The main aim of this paper is to provide a review and propose a classification of existing methodologies for scaffold design and optimization in order to address key issues and help in deciphering the complex link between design criteria and resulting scaffold properties.
Collapse
Affiliation(s)
- S M Giannitelli
- Tissue Engineering Laboratory, CIR - Center for Integrated Research, Università Campus Bio-Medico di Roma, via Alvaro del Portillo 21, 00128 Rome, Italy
| | - D Accoto
- Biomedical Robotics and Biomicrosystems Laboratory, CIR - Center for Integrated Research, Università Campus Bio-Medico di Roma, via Alvaro del Portillo 21, 00128 Rome, Italy
| | - M Trombetta
- Tissue Engineering Laboratory, CIR - Center for Integrated Research, Università Campus Bio-Medico di Roma, via Alvaro del Portillo 21, 00128 Rome, Italy
| | - A Rainer
- Tissue Engineering Laboratory, CIR - Center for Integrated Research, Università Campus Bio-Medico di Roma, via Alvaro del Portillo 21, 00128 Rome, Italy.
| |
Collapse
|
33
|
Luangphakdy V, Walker E, Shinohara K, Pan H, Hefferan T, Bauer TW, Stockdale L, Saini S, Dadsetan M, Runge MB, Vasanji A, Griffith L, Yaszemski M, Muschler GF. Evaluation of osteoconductive scaffolds in the canine femoral multi-defect model. Tissue Eng Part A 2013; 19:634-48. [PMID: 23215980 DOI: 10.1089/ten.tea.2012.0289] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Treatment of large segmental bone defects remains an unsolved clinical challenge, despite a wide array of existing bone graft materials. This project was designed to rapidly assess and compare promising biodegradable osteoconductive scaffolds for use in the systematic development of new bone regeneration methodologies that combine scaffolds, sources of osteogenic cells, and bioactive scaffold modifications. Promising biomaterials and scaffold fabrication methods were identified in laboratories at Rutgers, MIT, Integra Life Sciences, and Mayo Clinic. Scaffolds were fabricated from various materials, including poly(L-lactide-co-glycolide) (PLGA), poly(L-lactide-co-ɛ-caprolactone) (PLCL), tyrosine-derived polycarbonate (TyrPC), and poly(propylene fumarate) (PPF). Highly porous three-dimensional (3D) scaffolds were fabricated by 3D printing, laser stereolithography, or solvent casting followed by porogen leaching. The canine femoral multi-defect model was used to systematically compare scaffold performance and enable selection of the most promising substrate(s) on which to add cell sourcing options and bioactive surface modifications. Mineralized cancellous allograft (MCA) was used to provide a comparative reference to the current clinical standard for osteoconductive scaffolds. Percent bone volume within the defect was assessed 4 weeks after implantation using both MicroCT and limited histomorphometry. Bone formed at the periphery of all scaffolds with varying levels of radial ingrowth. MCA produced a rapid and advanced stage of bone formation and remodeling throughout the defect in 4 weeks, greatly exceeding the performance of all polymer scaffolds. Two scaffold constructs, TyrPC(PL)/TCP and PPF4(SLA)/HA(PLGA) (Dip), proved to be significantly better than alternative PLGA and PLCL scaffolds, justifying further development. MCA remains the current standard for osteoconductive scaffolds.
Collapse
Affiliation(s)
- Viviane Luangphakdy
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Dorati R, Colonna C, Tomasi C, Genta I, Bruni G, Conti B. Design of 3D scaffolds for tissue engineering testing a tough polylactide-based graft copolymer. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 34:130-9. [PMID: 24268242 DOI: 10.1016/j.msec.2013.08.037] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 07/29/2013] [Accepted: 08/29/2013] [Indexed: 11/17/2022]
Abstract
The aim of this research was to investigate a tough polymer to develop 3D scaffolds and 2D films for tissue engineering applications, in particular to repair urethral strictures or defects. The polymer tested was a graft copolymer of polylactic acid (PLA) synthesized with the rationale to improve the toughness of the related PLA homopolymer. The LMP-3055 graft copolymer (in bulk) demonstrated to have negligible cytotoxicity (bioavailability >85%, MTT test). Moreover, the LMP-3055 sterilized through gamma rays resulted to be cytocompatible and non-toxic, and it has a positive effect on cell biofunctionality, promoting the cell growth. 3D scaffolds and 2D film were prepared using different LMP-3055 polymer concentrations (7.5, 10, 12.5 and 15%, w/v), and the effect of polymer concentration on pore size, porosity and interconnectivity of the 3D scaffolds and 2D film was investigated. 3D scaffolds got better results for fulfilling structural and biofunctional requirements: porosity, pore size and interconnectivity, cell attachment and proliferation. 3D scaffolds obtained with 10 and 12.5% polymer solutions (3D-2 and 3D-3, respectively) were identified as the most suitable construct for the cell attachment and proliferation presenting pore size ranged between 100 and 400μm, high porosity (77-78%) and well interconnected pores. In vitro cell studies demonstrated that all the selected scaffolds were able to support the cell proliferation, the cell attachment and growth resulting to their dependency on the polymer concentration and structural features. The degradation test revealed that the degradation of polymer matrix (ΔMw) and water uptake of 3D scaffolds exceed those of 2D film and raw polymer (used as control reference), while the mass loss of samples (3D scaffold and 2D film) resulted to be controlled, they showed good stability and capacity to maintain the physical integrity during the incubation time.
Collapse
Affiliation(s)
- R Dorati
- Department of Drug Sciences, University of Pavia, V.le Taramelli 12, 27100 Pavia, Italy; Center for Tissue Engineering (CIT), University of Pavia, Via Ferrata 1, 27100 Pavia, Italy.
| | | | | | | | | | | |
Collapse
|
35
|
Bagherzadeh R, Latifi M, Kong L. Three-dimensional pore structure analysis of polycaprolactone nano-microfibrous scaffolds using theoretical and experimental approaches. J Biomed Mater Res A 2013; 102:903-10. [PMID: 23554325 DOI: 10.1002/jbm.a.34736] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2013] [Accepted: 03/07/2013] [Indexed: 12/25/2022]
Abstract
In this article the pore structure and porosity parameters of polycaprolactone (PCL) nano-microfibrous scaffolds are investigated using a predicting theoretical model and a nondestructive evaluation approach based on confocal laser scanning microscopy (CLSM) and three-dimensional image analysis. Different fibrous scaffolds with different fiber diameters produced by electrospinning process and their 3D-pore structure were evaluated theoretically and also compared to results of CLSM and capillary flow porometery methods. The effect of polymer concentration on the pore structure of scaffolds was also investigated. The results showed that, the introduced approach not only can measure the pore size distribution of nanofibrous scaffolds, but also can measure pore interconnectivity of fibrous scaffolds. Furthermore, the results showed that increasing the fiber diameter resulted from increasing the polymer concentration in solvent can effectively increase the pore dimensions within the scaffold structure.
Collapse
Affiliation(s)
- Roohollah Bagherzadeh
- ATMT Research Institute, Textile Engineering Department, Amirkabir University of Technology, Tehran, Iran; Institute for Frontier Materials, Deakin University, Waurn Ponds, VIC 3216, Australia
| | | | | |
Collapse
|
36
|
Castilho M, Dias M, Gbureck U, Groll J, Fernandes P, Pires I, Gouveia B, Rodrigues J, Vorndran E. Fabrication of computationally designed scaffolds by low temperature 3D printing. Biofabrication 2013; 5:035012. [PMID: 23887064 DOI: 10.1088/1758-5082/5/3/035012] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The development of artificial bone substitutes that mimic the properties of bone and simultaneously promote the desired tissue regeneration is a current issue in bone tissue engineering research. An approach to create scaffolds with such characteristics is based on the combination of novel design and additive manufacturing processes. The objective of this work is to characterize the microstructural and the mechanical properties of scaffolds developed by coupling both topology optimization and a low temperature 3D printing process. The scaffold design was obtained using a topology optimization approach to maximize the permeability with constraints on the mechanical properties. This procedure was studied to be suitable for the fabrication of a cage prototype for tibial tuberosity advancement application, which is one of the most recent and promising techniques to treat cruciate ligament rupture in dogs. The microstructural and mechanical properties of the scaffolds manufactured by reacting α/β-tricalcium phosphate with diluted phosphoric acid were then assessed experimentally and the scaffolds strength reliability was determined. The results demonstrate that the low temperature 3D printing process is a reliable option to create synthetic scaffolds with tailored properties, and when coupled with topology optimization design it can be a powerful tool for the fabrication of patient-specific bone implants.
Collapse
Affiliation(s)
- Miguel Castilho
- Institute of Mechanical Engineering/IST, Technical University of Lisbon, Portugal.
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Nakada A, Shigeno K, Sato T, Kobayashi T, Wakatsuki M, Uji M, Nakamura T. Manufacture of a weakly denatured collagen fiber scaffold with excellent biocompatibility and space maintenance ability. Biomed Mater 2013; 8:045010. [DOI: 10.1088/1748-6041/8/4/045010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
38
|
Ylä-Soininmäki A, Moritz N, Turco G, Paoletti S, Aro HT. Quantitative characterization of porous commercial and experimental bone graft substitutes with microcomputed tomography. J Biomed Mater Res B Appl Biomater 2013; 101:1538-48. [DOI: 10.1002/jbm.b.32975] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Revised: 03/26/2013] [Accepted: 04/23/2013] [Indexed: 12/18/2022]
Affiliation(s)
- Anne Ylä-Soininmäki
- Orthopaedic Research Unit; Department of Orthopaedic Surgery and Traumatology; University of Turku; Turku Finland
| | - Niko Moritz
- Orthopaedic Research Unit; Department of Orthopaedic Surgery and Traumatology; University of Turku; Turku Finland
- Turku Centre for Clinical Biomaterials-TCBC; Institute of Dentistry; University of Turku; Turku Finland
| | - Gianluca Turco
- Department of Life Sciences; University of Trieste; Trieste Italy
| | - Sergio Paoletti
- Department of Life Sciences; University of Trieste; Trieste Italy
| | - Hannu T. Aro
- Orthopaedic Research Unit; Department of Orthopaedic Surgery and Traumatology; University of Turku; Turku Finland
| |
Collapse
|
39
|
Saito E, Suarez-Gonzalez D, Rao RR, Stegemann JP, Murphy WL, Hollister SJ. Use of micro-computed tomography to nondestructively characterize biomineral coatings on solid freeform fabricated poly (L-lactic acid) and poly ((ε-caprolactone) scaffolds in vitro and in vivo. Tissue Eng Part C Methods 2013; 19:507-17. [PMID: 23134479 DOI: 10.1089/ten.tec.2012.0495] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Biomineral coatings have been extensively used to enhance the osteoconductivity of polymeric scaffolds. Numerous porous scaffolds have previously been coated with a bone-like apatite mineral through incubation in simulated body fluid (SBF). However, characterization of the mineral layer formed on scaffolds, including the amount of mineral within the scaffolds, often requires destructive methods. We have developed a method using micro-computed tomography (μ-CT) scanning to nondestructively quantify the amount of mineral in vitro and in vivo on biodegradable scaffolds made of poly (L-lactic acid) (PLLA) and poly (ε-caprolactone) (PCL). PLLA and PCL scaffolds were fabricated using an indirect solid freeform fabrication (SFF) technique to achieve orthogonally interconnected pore architectures. Biomineral coatings were formed on the fabricated PLLA and PCL scaffolds after incubation in modified SBF (mSBF). Scanning electron microscopy and X-ray diffraction confirmed the formation of an apatite-like mineral. The scaffolds were implanted into mouse ectopic sites for 3 and 10 weeks. The presence of a biomineral coating within the porous scaffolds was confirmed through plastic embedding and μ-CT techniques. Tissue mineral content (TMC) and volume of mineral on the scaffold surfaces detected by μ-CT had a strong correlation with the amount of calcium measured by the orthocresolphthalein complex-one (OCPC) method before and after implantation. There was a strong correlation between OCPC pre- and postimplantation and μ-CT measured TMC (R(2)=0.96 preimplant; R(2)=0.90 postimplant) and mineral volume (R(2)=0.96 preimplant; R(2)=0.89 postimplant). The μ-CT technique showed increases in mineral following implantation, suggesting that μ-CT can be used to nondestructively determine the amount of calcium on coated scaffolds.
Collapse
Affiliation(s)
- Eiji Saito
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | | | | | | | | | | |
Collapse
|
40
|
Wang X, Schröder HC, Feng Q, Draenert F, Müller WEG. The deep-sea natural products, biogenic polyphosphate (Bio-PolyP) and biogenic silica (Bio-Silica), as biomimetic scaffolds for bone tissue engineering: fabrication of a morphogenetically-active polymer. Mar Drugs 2013; 11:718-46. [PMID: 23528950 PMCID: PMC3705367 DOI: 10.3390/md11030718] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 02/04/2013] [Accepted: 02/06/2013] [Indexed: 12/12/2022] Open
Abstract
Bone defects in human, caused by fractures/nonunions or trauma, gain increasing impact and have become a medical challenge in the present-day aging population. Frequently, those fractures require surgical intervention which ideally relies on autografts or suboptimally on allografts. Therefore, it is pressing and likewise challenging to develop bone substitution materials to heal bone defects. During the differentiation of osteoblasts from their mesenchymal progenitor/stem cells and of osteoclasts from their hemopoietic precursor cells, a lineage-specific release of growth factors and a trans-lineage homeostatic cross-talk via signaling molecules take place. Hence, the major hurdle is to fabricate a template that is functioning in a way mimicking the morphogenetic, inductive role(s) of the native extracellular matrix. In the last few years, two naturally occurring polymers that are produced by deep-sea sponges, the biogenic polyphosphate (bio-polyP) and biogenic silica (bio-silica) have also been identified as promoting morphogenetic on both osteoblasts and osteoclasts. These polymers elicit cytokines that affect bone mineralization (hydroxyapatite formation). In this manner, bio-silica and bio-polyP cause an increased release of BMP-2, the key mediator activating the anabolic arm of the hydroxyapatite forming cells, and of RANKL. In addition, bio-polyP inhibits the progression of the pre-osteoclasts to functionally active osteoclasts. Based on these findings, new bioinspired strategies for the fabrication of bone biomimetic templates have been developed applying 3D-printing techniques. Finally, a strategy is outlined by which these two morphogenetically active polymers might be used to develop a novel functionally active polymer.
Collapse
Affiliation(s)
- Xiaohong Wang
- ERC Advanced Investigator Grant Research Group at Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Duesbergweg 6, D-55128 Mainz, Germany; E-Mail:
- National Research Center for Geoanalysis, Chinese Academy of Geological Sciences, 26 Baiwanzhuang Dajie, 100037 Beijing, China
| | - Heinz C. Schröder
- ERC Advanced Investigator Grant Research Group at Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Duesbergweg 6, D-55128 Mainz, Germany; E-Mail:
| | - Qingling Feng
- Department of Materials Science and Engineering, Tsinghua University, 100084 Beijing, China; E-Mail:
| | - Florian Draenert
- Department and Clinic for Oral and Maxillofacial Surgery, Baldingerstraße, D-35033 Marburg, Germany; E-Mail:
| | - Werner E. G. Müller
- ERC Advanced Investigator Grant Research Group at Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Duesbergweg 6, D-55128 Mainz, Germany; E-Mail:
| |
Collapse
|
41
|
Bagherzadeh R, Najar SS, Latifi M, Tehran MA, Kong L. A theoretical analysis and prediction of pore size and pore size distribution in electrospun multilayer nanofibrous materials. J Biomed Mater Res A 2013; 101:2107-17. [PMID: 23426993 DOI: 10.1002/jbm.a.34487] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 10/02/2012] [Accepted: 10/08/2012] [Indexed: 12/26/2022]
Abstract
Electrospinning process can fabricate nanomaterials with unique nanostructures for potential biomedical and environmental applications. However, the prediction and, consequently, the control of the porous structure of these materials has been impractical due to the complexity of the electrospinning process. In this research, a theoretical model for characterizing the porous structure of the electrospun nanofibrous network has been developed by combining the stochastic and stereological probability approaches. From consideration of number of fiber-to-fiber contacts in an electrospun nanofibrous assembly, geometrical and statistical theory relating morphological and structural parameters of the network to the characteristic dimensions of interfibers pores is provided. It has been shown that these properties are strongly influenced by the fiber diameter, porosity, and thickness of assembly. It is also demonstrated that at a given network porosity, increasing fiber diameter and thickness of the network reduces the characteristic dimensions of pores. It is also discussed that the role of fiber diameter and number of the layer in the assembly is dominant in controlling the pore size distribution of the networks. The theory has been validated experimentally and results compared with the existing theory to predict the pore size distribution of nanofiber mats. It is believed that the presented theory for estimation of pore size distribution is more realistic and useful for further studies of multilayer random nanofibrous assemblies.
Collapse
Affiliation(s)
- Roohollah Bagherzadeh
- Textile Engineering Department, ATMT Research Institute, Amirkabir University of Technology, Tehran, Iran.
| | | | | | | | | |
Collapse
|
42
|
Computer-Aided Tissue Engineering: Application to the Case of Anterior Cruciate Ligament Repair. LECTURE NOTES IN COMPUTATIONAL VISION AND BIOMECHANICS 2013. [DOI: 10.1007/978-94-007-5890-2_1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
43
|
Kitson PJ, Symes MD, Dragone V, Cronin L. Combining 3D printing and liquid handling to produce user-friendly reactionware for chemical synthesis and purification. Chem Sci 2013. [DOI: 10.1039/c3sc51253c] [Citation(s) in RCA: 142] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
44
|
Strauß S, Dudziak S, Hagemann R, Barcikowski S, Fliess M, Israelowitz M, Kracht D, Kuhbier JW, Radtke C, Reimers K, Vogt PM. Induction of osteogenic differentiation of adipose derived stem cells by microstructured nitinol actuator-mediated mechanical stress. PLoS One 2012; 7:e51264. [PMID: 23236461 PMCID: PMC3517541 DOI: 10.1371/journal.pone.0051264] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2012] [Accepted: 10/31/2012] [Indexed: 12/16/2022] Open
Abstract
The development of large tissue engineered bone remains a challenge in vitro, therefore the use of hybrid-implants might offer a bridge between tissue engineering and dense metal or ceramic implants. Especially the combination of the pseudoelastic implant material Nitinol (NiTi) with adipose derived stem cells (ASCs) opens new opportunities, as ASCs are able to differentiate osteogenically and therefore enhance osseointegration of implants. Due to limited knowledge about the effects of NiTi-structures manufactured by selective laser melting (SLM) on ASCs the study started with an evaluation of cytocompatibility followed by the investigation of the use of SLM-generated 3-dimensional NiTi-structures preseeded with ASCs as osteoimplant model. In this study we could demonstrate for the first time that osteogenic differentiation of ASCs can be induced by implant-mediated mechanical stimulation without support of osteogenic cell culture media. By use of an innovative implant design and synthesis via SLM-technique we achieved high rates of vital cells, proper osteogenic differentiation and mechanically loadable NiTi-scaffolds could be achieved.
Collapse
Affiliation(s)
- Sarah Strauß
- Department of Plastic-, Hand- and Reconstructive Surgery, Hannover Medical School, Hannover, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Bagherzadeh R, Latifi M, Najar SS, Tehran MA, Kong L. Three-dimensional pore structure analysis of Nano/Microfibrous scaffolds using confocal laser scanning microscopy. J Biomed Mater Res A 2012; 101:765-74. [DOI: 10.1002/jbm.a.34379] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2012] [Revised: 06/16/2012] [Accepted: 07/02/2012] [Indexed: 12/24/2022]
|
46
|
Enhancement of bone regeneration through facile surface functionalization of solid freeform fabrication-based three-dimensional scaffolds using mussel adhesive proteins. Acta Biomater 2012; 8:2578-86. [PMID: 22480947 DOI: 10.1016/j.actbio.2012.03.041] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Revised: 03/03/2012] [Accepted: 03/27/2012] [Indexed: 01/14/2023]
Abstract
Solid freeform fabrication (SFF) is recognized as a promising tool for creating tissue engineering scaffolds due to advantages such as superior interconnectivity and highly porous structure. Despite structural support for SFF-based three-dimensional (3-D) scaffolds that can lead to tissue regeneration, lack of cell recognition motifs and/or biochemical factors has been considered a limitation. Previously, recombinant mussel adhesive proteins (MAPs) were successfully demonstrated to be functional cell adhesion materials on various surfaces due to their peculiar adhesive properties. Herein, MAPs were applied as surface functionalization materials to SFF-based 3-D polycaprolactone/poly(lactic-co-glycolic acid) scaffolds. We successfully coated MAPs onto scaffold surfaces by simply dipping the scaffolds into the MAP solution, which was confirmed through X-ray photoelectron spectroscopy and scanning electron microscopy analyses. Through in vitro study using human adipose tissue-derived stem cells (hADSCs), significant enhancement of cellular activities such as attachment, proliferation, and osteogenic differentiation was observed on MAP-coated 3-D scaffolds, especially on which fused arginine-glycine-aspartic acid peptides were efficiently exposed. In addition, we found that in vivo hADSC implantation with MAP-coated scaffolds enhanced bone regeneration in a rat calvarial defect model. These results collectively demonstrate that facile surface functionalization of 3-D scaffolds using MAP would be a promising strategy for successful tissue engineering applications.
Collapse
|
47
|
Saito E, Liu Y, Migneco F, Hollister SJ. Strut size and surface area effects on long-term in vivo degradation in computer designed poly(L-lactic acid) three-dimensional porous scaffolds. Acta Biomater 2012; 8:2568-77. [PMID: 22446030 DOI: 10.1016/j.actbio.2012.03.028] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 02/29/2012] [Accepted: 03/14/2012] [Indexed: 01/06/2023]
Abstract
Current developments in computer-aided design (CAD) and solid free-form fabrication (SFF) techniques enable fabrication of scaffolds with precisely designed architectures and mechanical properties. The present study demonstrates the effect of precisely designed three-dimensional scaffold architectures on in vivo degradation. Specifically, three types of porous poly(L-lactic acid) (PLLA) scaffolds with variable pore sizes, strut sizes, porosities, and surface areas fabricated by indirect SFF. In addition, one experimental group of PLLA solid cylinders was fabricated. The scaffolds and cylinders were subcutaneously implanted into mice for 6, 12 and 21 weeks. The solid cylinders exhibited a faster percentage mass loss than all porous scaffolds. Among the porous scaffolds the group with the largest strut size lost percentage mass faster than the other two groups. Strong correlations between surface area and percentage mass loss were found at 12 (R(2)=0.681) and 21 (R(2)=0.671) weeks. Scaffold porosity, however, was not significantly correlated with degradation rate. Changes in molecular weight and crystallinity also resulted in changes in the chemical structures due to degradation, and the solid cylinders had faster crystallization due to more advanced degradation than the porous scaffolds. Scaffold compressive moduli decreased with degradation, but the resulting modulus was still within the lower range of human trabecular bone even after 21 weeks. The loss in compressive moduli, however, was a complex function of both degradation and the initial scaffold architecture. This study suggests that CAD and fabrication, within a given material, can significantly influence scaffold degradation profiles.
Collapse
|
48
|
Integrated 3D-printed reactionware for chemical synthesis and analysis. Nat Chem 2012; 4:349-54. [DOI: 10.1038/nchem.1313] [Citation(s) in RCA: 493] [Impact Index Per Article: 41.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2011] [Accepted: 02/23/2012] [Indexed: 11/08/2022]
|
49
|
Ciocca L, Donati D, Fantini M, Landi E, Piattelli A, Iezzi G, Tampieri A, Spadari A, Romagnoli N, Scotti R. CAD-CAM-generated hydroxyapatite scaffold to replace the mandibular condyle in sheep: preliminary results. J Biomater Appl 2012; 28:207-18. [PMID: 22492196 DOI: 10.1177/0885328212443296] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, rapid CAD-CAM prototyping of pure hydroxyapatite to replace temporomandibular joint condyles was tested in sheep. Three adult animals were implanted with CAD-CAM-designed porous hydroxyapatite scaffolds as condyle substitutes. The desired scaffold shape was achieved by subtractive automated milling machining (block reduction). Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Using the same technique, fixation plates were created and applied to the scaffold pre-operatively to firmly secure the condyles to the bone and to assure primary stability of the hydroxyapatite scaffolds during masticatory function. Four months post-surgery, the sheep were sacrificed. The hydroxyapatite scaffolds were explanted, and histological specimens were prepared. Different histological tissues penetrating the scaffold macropores, the sequence of bone remodeling, new apposition of bone and/or cartilage as a consequence of the different functional anatomic role, and osseointegration at the interface between the scaffold and bone were documented. This animal model was found to be appropriate for testing CAD-CAM customization and the biomechanical properties of porous, pure hydroxyapatite scaffolds used as joint prostheses.
Collapse
Affiliation(s)
- Leonardo Ciocca
- Department of Oral Science, Alma Mater Studiorum University of Bologna, Bologna, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Lee JTY, Chow KL. SEM sample preparation for cells on 3D scaffolds by freeze-drying and HMDS. SCANNING 2012; 34:12-25. [PMID: 22532079 DOI: 10.1002/sca.20271] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2011] [Accepted: 07/06/2011] [Indexed: 05/06/2023]
Abstract
Common dehydration methods of cells on biomaterials for scanning electron microscopy (SEM) include air drying, hexamethyldisilazane (HMDS) or tetramethysilane (TMS) treatment and critical point drying (CPD). On the other side, freeze-drying has been widely employed in dehydrating biological samples and also in preparing porous biomaterial scaffolds but not in preparing cells on three-dimensional (3D) biomaterials for SEM examination. In this study, we compare cells on porous hydroxyapatite (HA) prepared by air drying, HMDS and freeze-drying. The effects of fixation and using phosphate buffered saline (PBS) in the fixation were also assessed on three porous calcium phosphate (CaP) materials, namely, HA, α-tricalcium phosphate (α-TCP) and β-tricalcium phosphate (β-TCP) samples. There is no significant difference in samples prepared by HMDS treatment and freeze-drying viewed at low magnification. Besides, it is better not to use phosphate buffer in the fixation step for CaP materials to avoid undesirable spontaneous precipitation of CaPs. On the other hand, fewer exchanges of liquids are required for freeze-drying and hence chemical fixation may not be absolutely required for samples prepared by freeze-drying. Other technical details of the preparation were also investigated and discussed. This study suggests both HMDS and freeze-drying can be employed to dehydrate cells on 3D scaffolds for SEM examination.
Collapse
Affiliation(s)
- Juliana Tsz Yan Lee
- Bioengineering Graduate Program, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
| | | |
Collapse
|