1
|
Sui J, Lin Z, Azizpour S, Chen F, Gaur S, Keene K, Soleimani F, Bhowmick T, Rafique Z, Javanmard M. Clinical evaluation of a fully electronic microfluidic white blood cell analyzer. PLoS One 2024; 19:e0296344. [PMID: 38236796 PMCID: PMC10796056 DOI: 10.1371/journal.pone.0296344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 11/11/2023] [Indexed: 01/22/2024] Open
Abstract
The White Blood Cell (WBC) count is one of the key parameters signaling the health of the immune system. Abnormal WBC counts often signal a systemic insult to the body such as an underlying infection or an adverse side effect to medication. Typically, the blood collected is sent to a central lab for testing, and results come back within hours, which is often inconvenient and may delay time-sensitive diagnosis or treatment. Here, we present the CytoTracker, a fully electronic, microfluidic based instant WBC analyzer with the potential to be used at point-of-care. The CytoTracker is a lightweight, portable, affordable platform capable of quantifying WBCs within minutes using only 50 μl of blood (approximately one drop of blood). In this study, we clinically evaluated the accuracy and performance of CytoTracker in measuring WBC and granulocyte counts. A total of 210 adult patients were recruited in the study. We validated the CytoTracker against a standard benchtop analyzer (Horiba Point of Care Hematology Analyzer, ABX Micros 60). Linear dynamic ranges of 2.5 k/μl- 35 k/μl and 0.6 k/μl- 26 k/μl were achieved for total WBC count and granulocyte count with correlation coefficients of 0.97 and 0.98. In addition, we verified CytoTracker's capability of identifying abnormal blood counts with above 90% sensitivity and specificity. The promising results of this clinical validation study demonstrate the potential for the use of the CytoTracker as a reliable and accurate point-of-care WBC analyzer.
Collapse
Affiliation(s)
- Jianye Sui
- RizLab Health, Inc., Princeton, New Jersey, United States of America
| | - Zhongtian Lin
- RizLab Health, Inc., Princeton, New Jersey, United States of America
| | - Shahriar Azizpour
- RizLab Health, Inc., Princeton, New Jersey, United States of America
| | - Fei Chen
- Department of Pediatrics, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, United States of America
| | - Sunanda Gaur
- Department of Pediatrics, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, United States of America
| | - Kelly Keene
- Department of Emergency Medicine, Baylor College of Medicine, Houston, Texas, United States of America
| | - Farzad Soleimani
- Department of Emergency Medicine, Baylor College of Medicine, Houston, Texas, United States of America
| | - Tanaya Bhowmick
- Department of Medicine, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey, United States of America
| | - Zubaid Rafique
- Department of Emergency Medicine, Baylor College of Medicine, Houston, Texas, United States of America
| | - Mehdi Javanmard
- RizLab Health, Inc., Princeton, New Jersey, United States of America
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, New Jersey, United States of America
| |
Collapse
|
2
|
Oladokun R, Adekanmbi EO, An V, Gangavaram I, Srivastava SK. Dielectrophoretic profiling of erythrocytes to study the impacts of metabolic stress, temperature, and storage duration utilizing a point-and-planar microdevice. Sci Rep 2023; 13:17281. [PMID: 37828082 PMCID: PMC10570315 DOI: 10.1038/s41598-023-44022-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 10/03/2023] [Indexed: 10/14/2023] Open
Abstract
Dielectrophoresis (DEP) is widely utilized for trapping and sorting various types of cells, including live and dead cells and healthy and infected cells. This article focuses on the dielectric characterization of erythrocytes (red blood cells or RBCs) by quantifying DEP crossover frequency using a novel point-and-planar microwell device platform. Numerical simulations using COMSOL Multiphysics software demonstrate that the distribution of the DEP force is influenced by factors such as the shape of the point electrode, spacing between the point and planar electrodes, and the type of bioparticle being investigated. The dependency on electrode spacing is experimentally evaluated by analyzing the DEP crossover response of erythrocytes. Furthermore, the results are validated against the traditional electrical characterization technique called electrorotation, which typically requires laborious fabrication and operation using quadrupole electrodes. Other significant factors, including erythrocyte storage age and the changes in cell properties over time since collection, osmolarity, and temperature, are also assessed to determine the optimal conditions for erythrocyte characterization. The findings indicate a significant difference between fresh and stored erythrocyte samples (up to 4 days), highlighting the importance of maintaining an isotonic medium for cell storage.
Collapse
Affiliation(s)
- Raphael Oladokun
- Department of Chemical and Biomedical Engineering, West Virginia University, 1306 Evansdale Dr., PO Box 6102, Morgantown, WV, 26506-6102, USA
| | | | - Vanessa An
- Summer 2022 High School Intern, Department of Chemical and Biomedical Engineering, West Virginia University, Morgantown, WV, USA
| | - Isha Gangavaram
- Summer 2022 High School Intern, Department of Chemical and Biomedical Engineering, West Virginia University, Morgantown, WV, USA
| | - Soumya K Srivastava
- Department of Chemical and Biomedical Engineering, West Virginia University, 1306 Evansdale Dr., PO Box 6102, Morgantown, WV, 26506-6102, USA.
| |
Collapse
|
3
|
Julian T, Tang T, Hosokawa Y, Yalikun Y. Machine learning implementation strategy in imaging and impedance flow cytometry. BIOMICROFLUIDICS 2023; 17:051506. [PMID: 37900052 PMCID: PMC10613093 DOI: 10.1063/5.0166595] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 10/06/2023] [Indexed: 10/31/2023]
Abstract
Imaging and impedance flow cytometry is a label-free technique that has shown promise as a potential replacement for standard flow cytometry. This is due to its ability to provide rich information and archive high-throughput analysis. Recently, significant efforts have been made to leverage machine learning for processing the abundant data generated by those techniques, enabling rapid and accurate analysis. Harnessing the power of machine learning, imaging and impedance flow cytometry has demonstrated its capability to address various complex phenotyping scenarios. Herein, we present a comprehensive overview of the detailed strategies for implementing machine learning in imaging and impedance flow cytometry. We initiate the discussion by outlining the commonly employed setup to acquire the data (i.e., image or signal) from the cell. Subsequently, we delve into the necessary processes for extracting features from the acquired image or signal data. Finally, we discuss how these features can be utilized for cell phenotyping through the application of machine learning algorithms. Furthermore, we discuss the existing challenges and provide insights for future perspectives of intelligent imaging and impedance flow cytometry.
Collapse
Affiliation(s)
- Trisna Julian
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara 630-0192, Japan
| | - Tao Tang
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara 630-0192, Japan
| | | |
Collapse
|
4
|
Tang T, Julian T, Ma D, Yang Y, Li M, Hosokawa Y, Yalikun Y. A review on intelligent impedance cytometry systems: Development, applications and advances. Anal Chim Acta 2023; 1269:341424. [PMID: 37290859 DOI: 10.1016/j.aca.2023.341424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 05/22/2023] [Accepted: 05/23/2023] [Indexed: 06/10/2023]
Abstract
Impedance cytometry is a well-established technique for counting and analyzing single cells, with several advantages, such as convenience, high throughput, and no labeling required. A typical experiment consists of the following steps: single-cell measurement, signal processing, data calibration, and particle subtype identification. At the beginning of this article, we compared commercial and self-developed options extensively and provided references for developing reliable detection systems, which are necessary for cell measurement. Then, a number of typical impedance metrics and their relationships to biophysical properties of cells were analyzed with respect to the impedance signal analysis. Given the rapid advances of intelligent impedance cytometry in the past decade, this article also discussed the development of representative machine learning-based approaches and systems, and their applications in data calibration and particle identification. Finally, the remaining challenges facing the field were summarized, and potential future directions for each step of impedance detection were discussed.
Collapse
Affiliation(s)
- Tao Tang
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan; Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Trisna Julian
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan
| | - Doudou Ma
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yang Yang
- Institute of Deep-Sea Science and Engineering, Chinese Academy of Sciences, Sanya, Hainan, 572000, PR China
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, 2109, Australia
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan
| | - Yaxiaer Yalikun
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan; Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| |
Collapse
|
5
|
Khaleque MA, Hossain MI, Ali MR, Bacchu MS, Saad Aly MA, Khan MZH. Nanostructured wearable electrochemical and biosensor towards healthcare management: a review. RSC Adv 2023; 13:22973-22997. [PMID: 37529357 PMCID: PMC10387826 DOI: 10.1039/d3ra03440b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 06/29/2023] [Indexed: 08/03/2023] Open
Abstract
In recent years, there has been a rapid increase in demand for wearable sensors, particularly these tracking the surroundings, fitness, and health of people. Thus, selective detection in human body fluid is a demand for a smart lifestyle by quick monitoring of electrolytes, drugs, toxins, metabolites and biomolecules, proteins, and the immune system. In this review, these parameters along with the main features of the latest and mostly cited research work on nanostructured wearable electrochemical and biosensors are surveyed. This study aims to help researchers and engineers choose the most suitable selective and sensitive sensor. Wearable sensors have broad and effective sensing platforms, such as contact lenses, Google Glass, skin-patch, mouth gourds, smartwatches, underwear, wristbands, and others. For increasing sensor reliability, additional advancements in electrochemical and biosensor precision, stability in uncontrolled environments, and reproducible sample conveyance are necessary. In addition, the optimistic future of wearable electrochemical sensors in fields, such as remote and customized healthcare and well-being is discussed. Overall, wearable electrochemical and biosensing technologies hold great promise for improving personal healthcare and monitoring performance with the potential to have a significant impact on daily lives. These technologies enable real-time body sensing and the communication of comprehensive physiological information.
Collapse
Affiliation(s)
- M A Khaleque
- Dept. of Chemical Engineering, Jashore University of Science and Technology Jashore 7408 Bangladesh
- Laboratory of Nano-bio and Advanced Materials Engineering (NAME), Jashore University of Science and technology Jashore 7408 Bangladesh
| | - M I Hossain
- Dept. of Chemical Engineering, Jashore University of Science and Technology Jashore 7408 Bangladesh
- Laboratory of Nano-bio and Advanced Materials Engineering (NAME), Jashore University of Science and technology Jashore 7408 Bangladesh
| | - M R Ali
- Dept. of Chemical Engineering, Jashore University of Science and Technology Jashore 7408 Bangladesh
- Laboratory of Nano-bio and Advanced Materials Engineering (NAME), Jashore University of Science and technology Jashore 7408 Bangladesh
| | - M S Bacchu
- Dept. of Chemical Engineering, Jashore University of Science and Technology Jashore 7408 Bangladesh
- Laboratory of Nano-bio and Advanced Materials Engineering (NAME), Jashore University of Science and technology Jashore 7408 Bangladesh
| | - M Aly Saad Aly
- Department of Electrical and Computer Engineering at Georgia Tech Shenzhen Institute (GTSI), Tianjin University Shenzhen Guangdong 518055 China
| | - M Z H Khan
- Dept. of Chemical Engineering, Jashore University of Science and Technology Jashore 7408 Bangladesh
- Laboratory of Nano-bio and Advanced Materials Engineering (NAME), Jashore University of Science and technology Jashore 7408 Bangladesh
| |
Collapse
|
6
|
Li Y, Liu X, Zhang Y, Wu Z, Ling W, Zhang X, Zhou M, Onses MS, Zhou P, Mao S, Huo W, Fan Z, Yang H, Wang H, Huang X. A flexible wearable device coupled with injectable Fe 3O 4 nanoparticles for capturing circulating tumor cells and triggering their deaths. Biosens Bioelectron 2023; 235:115367. [PMID: 37187061 DOI: 10.1016/j.bios.2023.115367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 04/17/2023] [Accepted: 04/28/2023] [Indexed: 05/17/2023]
Abstract
Elimination of circulating tumor cells (CTCs) in the blood can be an effective therapeutic approach to disrupt metastasis. Here, a strategy is proposed to implement flexible wearable electronics and injectable nanomaterials to disrupt the hematogenous transport of CTCs. A flexible device containing an origami magnetic membrane is used to attract Fe3O4@Au nanoparticles (NPs) that are surface modified with specific aptamers and intravenously injected into blood vessels, forming an invisible hand and fishing line/bait configuration to specifically capture CTCs through bonding with aptamers. Thereafter, thinned flexible AlGaAs LEDs in the device offer an average fluence of 15.75 mW mm-2 at a skin penetration depth of 1.5 mm, causing a rapid rise of temperature to 48 °C in the NPs and triggering CTC death in 10 min. The flexible device has been demonstrated for intravascular isolation and enrichment of CTCs with a capture efficiency of 72.31% after 10 cycles in a simulated blood circulation system based on a prosthetic upper limb. The fusion of nanomaterials and flexible electronics reveals an emerging field that utilizes wearable and flexible stimulators to activate biological effects offered by nanomaterials, leading to improved therapeutical effects and postoperative outcomes of diseases.
Collapse
Affiliation(s)
- Ya Li
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Xinyu Liu
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Yingying Zhang
- School of Medical Imaging, Xuzhou Medical University, 209 Tongshan Road, Xuzhou, 221004, China
| | - Ziyue Wu
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Wei Ling
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Xinyu Zhang
- Department of Life Science, Tianjin University, 92 Weijin Road, Tianjin, 300072, China
| | - Mingxing Zhou
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - M Serdar Onses
- Department of Materials Science and Engineering, Erciyes University, Talas Yolu Melikgazi, Kayseri, 38039, Turkey
| | - Pan Zhou
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Sui Mao
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Wenxing Huo
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China
| | - Zhenzhen Fan
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China
| | - Hong Yang
- The Province and Ministry Co-Sponsored Collaborative Innovation Center for Medical Epigenetics, Department of Pharmacology, School of Basic Medical Sciences, School of Biomedical Engineering, Intensive Care Unit, The Second Hospital, Tianjin Medical University, 22 Qixiangtai Road, Tianjin, 300070, China
| | - Hanjie Wang
- Department of Life Science, Tianjin University, 92 Weijin Road, Tianjin, 300072, China.
| | - Xian Huang
- Department of Biomedical Engineering, Tianjin University, 92 Weijin Road, Tianjin, 300072, China; Center of Flexible Wearable Technology, Institute of Flexible Electronic Technology of Tsinghua, 906 Yatai Road, Jiaxing, 314006, China; Institute of Wearable Technology and Bioelectronics, Qiantang Science and Technology Innovation Center, 1002 23rd Street, Hangzhou, 310018, China.
| |
Collapse
|
7
|
Nguyen TH, Nguyen HA, Tran Thi YV, Hoang Tran D, Cao H, Chu Duc T, Bui TT, Do Quang L. Concepts, electrode configuration, characterization, and data analytics of electric and electrochemical microfluidic platforms: a review. Analyst 2023; 148:1912-1929. [PMID: 36928639 DOI: 10.1039/d2an02027k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
Microfluidic cytometry (MC) and electrical impedance spectroscopy (EIS) are two important techniques in biomedical engineering. Microfluidic cytometry has been utilized in various fields such as stem cell differentiation and cancer metastasis studies, and provides a simple, label-free, real-time method for characterizing and monitoring cellular fates. The impedance microdevice, including impedance flow cytometry (IFC) and electrical impedance spectroscopy (EIS), is integrated into MC systems. IFC measures the impedance of individual cells as they flow through a microfluidic device, while EIS measures impedance changes during binding events on electrode regions. There have been significant efforts to improve and optimize these devices for both basic research and clinical applications, based on the concepts, electrode configurations, and cell fates. This review outlines the theoretical concepts, electrode engineering, and data analytics of these devices, and highlights future directions for development.
Collapse
Affiliation(s)
- Thu Hang Nguyen
- University of Engineering and Technology, Vietnam National University, Hanoi, Vietnam.
| | | | - Y-Van Tran Thi
- University of Science, Vietnam National University, Hanoi, Vietnam.
| | | | - Hung Cao
- University of California, Irvine, USA
| | - Trinh Chu Duc
- University of Engineering and Technology, Vietnam National University, Hanoi, Vietnam.
| | - Tung Thanh Bui
- University of Engineering and Technology, Vietnam National University, Hanoi, Vietnam.
| | - Loc Do Quang
- University of Science, Vietnam National University, Hanoi, Vietnam.
| |
Collapse
|
8
|
Kokabi M, Sui J, Gandotra N, Pournadali Khamseh A, Scharfe C, Javanmard M. Nucleic Acid Quantification by Multi-Frequency Impedance Cytometry and Machine Learning. BIOSENSORS 2023; 13:bios13030316. [PMID: 36979528 PMCID: PMC10046493 DOI: 10.3390/bios13030316] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/15/2023] [Accepted: 02/20/2023] [Indexed: 06/10/2023]
Abstract
Determining nucleic acid concentrations in a sample is an important step prior to proceeding with downstream analysis in molecular diagnostics. Given the need for testing DNA amounts and its purity in many samples, including in samples with very small input DNA, there is utility of novel machine learning approaches for accurate and high-throughput DNA quantification. Here, we demonstrated the ability of a neural network to predict DNA amounts coupled to paramagnetic beads. To this end, a custom-made microfluidic chip is applied to detect DNA molecules bound to beads by measuring the impedance peak response (IPR) at multiple frequencies. We leveraged electrical measurements including the frequency and imaginary and real parts of the peak intensity within a microfluidic channel as the input of deep learning models to predict DNA concentration. Specifically, 10 different deep learning architectures are examined. The results of the proposed regression model indicate that an R_Squared of 97% with a slope of 0.68 is achievable. Consequently, machine learning models can be a suitable, fast, and accurate method to measure nucleic acid concentration in a sample. The results presented in this study demonstrate the ability of the proposed neural network to use the information embedded in raw impedance data to predict the amount of DNA concentration.
Collapse
Affiliation(s)
- Mahtab Kokabi
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA
| | - Jianye Sui
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA
| | - Neeru Gandotra
- Department of Genetics, Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06520, USA
| | | | - Curt Scharfe
- Department of Genetics, Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06520, USA
| | - Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA
| |
Collapse
|
9
|
Recent advances in non-optical microfluidic platforms for bioparticle detection. Biosens Bioelectron 2023; 222:114944. [PMID: 36470061 DOI: 10.1016/j.bios.2022.114944] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/17/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022]
Abstract
The effective analysis of the basic structure and functional information of bioparticles are of great significance for the early diagnosis of diseases. The synergism between microfluidics and particle manipulation/detection technologies offers enhanced system integration capability and test accuracy for the detection of various bioparticles. Most microfluidic detection platforms are based on optical strategies such as fluorescence, absorbance, and image recognition. Although optical microfluidic platforms have proven their capabilities in the practical clinical detection of bioparticles, shortcomings such as expensive components and whole bulky devices have limited their practicality in the development of point-of-care testing (POCT) systems to be used in remote and underdeveloped areas. Therefore, there is an urgent need to develop cost-effective non-optical microfluidic platforms for bioparticle detection that can act as alternatives to optical counterparts. In this review, we first briefly summarise passive and active methods for bioparticle manipulation in microfluidics. Then, we survey the latest progress in non-optical microfluidic strategies based on electrical, magnetic, and acoustic techniques for bioparticle detection. Finally, a perspective is offered, clarifying challenges faced by current non-optical platforms in developing practical POCT devices and clinical applications.
Collapse
|
10
|
Chen YS, Huang CH, Pai PC, Seo J, Lei KF. A Review on Microfluidics-Based Impedance Biosensors. BIOSENSORS 2023; 13:bios13010083. [PMID: 36671918 PMCID: PMC9855525 DOI: 10.3390/bios13010083] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/20/2022] [Accepted: 12/28/2022] [Indexed: 05/30/2023]
Abstract
Electrical impedance biosensors are powerful and continuously being developed for various biological sensing applications. In this line, the sensitivity of impedance biosensors embedded with microfluidic technologies, such as sheath flow focusing, dielectrophoretic focusing, and interdigitated electrode arrays, can still be greatly improved. In particular, reagent consumption reduction and analysis time-shortening features can highly increase the analytical capabilities of such biosensors. Moreover, the reliability and efficiency of analyses are benefited by microfluidics-enabled automation. Through the use of mature microfluidic technology, complicated biological processes can be shrunk and integrated into a single microfluidic system (e.g., lab-on-a-chip or micro-total analysis systems). By incorporating electrical impedance biosensors, hand-held and bench-top microfluidic systems can be easily developed and operated by personnel without professional training. Furthermore, the impedance spectrum provides broad information regarding cell size, membrane capacitance, cytoplasmic conductivity, and cytoplasmic permittivity without the need for fluorescent labeling, magnetic modifications, or other cellular treatments. In this review article, a comprehensive summary of microfluidics-based impedance biosensors is presented. The structure of this article is based on the different substrate material categorizations. Moreover, the development trend of microfluidics-based impedance biosensors is discussed, along with difficulties and challenges that may be encountered in the future.
Collapse
Affiliation(s)
- Yu-Shih Chen
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| | - Chun-Hao Huang
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| | - Ping-Ching Pai
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan
| | - Jungmok Seo
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
- Department of Electrical & Electronic Engineering, Yonsei University, Seoul 120-749, Republic of Korea
| | - Kin Fong Lei
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan
- Department of Electrical & Electronic Engineering, Yonsei University, Seoul 120-749, Republic of Korea
| |
Collapse
|
11
|
Tayyab M, Xie P, Sami MA, Raji H, Lin Z, Meng Z, Mahmoodi SR, Javanmard M. A portable analog front-end system for label-free sensing of proteins using nanowell array impedance sensors. Sci Rep 2022; 12:20119. [PMID: 36418852 PMCID: PMC9684124 DOI: 10.1038/s41598-022-23286-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 10/28/2022] [Indexed: 11/24/2022] Open
Abstract
Proteins are useful biomarkers for a wide range of applications such as cancer detection, discovery of vaccines, and determining exposure to viruses and pathogens. Here, we present a low-noise front-end analog circuit interface towards development of a portable readout system for the label-free sensing of proteins using Nanowell array impedance sensing with a form factor of approximately 35cm2. The electronic interface consists of a low-noise lock-in amplifier enabling reliable detection of changes in impedance as low as 0.1% and thus detection of proteins down to the picoMolar level. The sensitivity of our system is comparable to that of a commercial bench-top impedance spectroscope when using the same sensors. The aim of this work is to demonstrate the potential of using impedance sensing as a portable, low-cost, and reliable method of detecting proteins, thus inching us closer to a Point-of-Care (POC) personalized health monitoring system. We have demonstrated the utility of our system to detect antibodies at various concentrations and protein (45 pM IL-6) in PBS, however, our system has the capability to be used for assaying various biomarkers including proteins, cytokines, virus molecules and antibodies in a portable setting.
Collapse
Affiliation(s)
- Muhammad Tayyab
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Pengfei Xie
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Muhammad Ahsan Sami
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Hassan Raji
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Zhongtian Lin
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Zhuolun Meng
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Seyed Reza Mahmoodi
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA
| | - Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 08901, USA.
| |
Collapse
|
12
|
Yang M, Ye Z, Alsaab N, Farhat M, Chen PY. In-Vitro Demonstration of Ultra-Reliable, Wireless and Batteryless Implanted Intracranial Sensors Operated on Loci of Exceptional Points. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:287-295. [PMID: 35380967 DOI: 10.1109/tbcas.2022.3164697] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Vital signal monitoring, such as pulse, respiration rate, intra-organ and intra-vascular pressure, can provide important information for determination of clinic diagnosis, treatments, and surgical protocols. Nowadays, micromachined bioimplants, equipped with antennas for converting bio-signals to modulated radio transmissions, may allow remote continuous monitoring of patients' vital signs. Yet, current passive biotelemetry techniques usually suffer from poor signal reproducibility and robustness in light of inevitable misalignment between transmitting and receiving antennas. Here, we seek to address this long-existing challenge and to robustly acquire information from a passive wireless intracranial pressure (or brain pressure) sensor by introducing a novel, high-performance biotelemetry system. In spite of variable inductive links, this biotelemetry system may have absolute accuracy by leveraging the uniqueness of loci of exceptional points (EPs) in non-Hermitian radio-frequency (RF) electronic systems with parity-time (PT) symmetry. Our in-vitro experimental demonstration shows that the proposed intracranial (ICP) monitoring system can provide a sub-mmHg resolution in the ICP range of 0-20 mmHg and ultra-robust wireless data acquisition against the misalignment-induced weakening of inductive link. Our results could provide a practical pathway toward reliable, real-time wireless monitoring of ICP, and other vital signals generated by bio-implants and wearables.
Collapse
|
13
|
Nakajima T, Fujio Y, Sugahara T, Tsuchiya T. Flexible Ceramic Film Sensors for Free-Form Devices. SENSORS (BASEL, SWITZERLAND) 2022; 22:1996. [PMID: 35271141 PMCID: PMC8914772 DOI: 10.3390/s22051996] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 03/01/2022] [Accepted: 03/02/2022] [Indexed: 02/06/2023]
Abstract
Recent technological innovations, such as material printing techniques and surface functionalization, have significantly accelerated the development of new free-form sensors for next-generation flexible, wearable, and three-dimensional electronic devices. Ceramic film sensors, in particular, are in high demand for the production of reliable flexible devices. Various ceramic films can now be formed on plastic substrates through the development of low temperature fabrication processes for ceramic films, such as photocrystallization and transferring methods. Among flexible sensors, strain sensors for precise motion detection and photodetectors for biomonitoring have seen the most research development, but other fundamental sensors for temperature and humidity have also begun to grow. Recently, flexible gas and electrochemical sensors have attracted a lot of attention from a new real-time monitoring application that uses human breath and perspiration to accurately diagnose presymptomatic states. The development of a low-temperature fabrication process of ceramic film sensors and related components will complete the chemically stable and reliable free-form sensing devices by satisfying the demands that can only be addressed by flexible metal and organic components.
Collapse
Affiliation(s)
- Tomohiko Nakajima
- Advanced Manufacturing Research Institute, National Institute of Advanced Industrial Science and Technology, Ibaraki 305-8565, Japan;
| | - Yuki Fujio
- Sensing System Research Center, National Institute of Advanced Industrial Science and Technology, Saga 841-0052, Japan;
| | - Tohru Sugahara
- Department of Energy and Environmental Materials, SANKEN, Osaka University, Osaka 567-0047, Japan;
| | - Tetsuo Tsuchiya
- Advanced Manufacturing Research Institute, National Institute of Advanced Industrial Science and Technology, Ibaraki 305-8565, Japan;
| |
Collapse
|
14
|
Jeerapan I, Moonla C, Thavarungkul P, Kanatharana P. Lab on a body for biomedical electrochemical sensing applications: The next generation of microfluidic devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:249-279. [PMID: 35094777 DOI: 10.1016/bs.pmbts.2021.07.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This chapter highlights applications of microfluidic devices toward on-body biosensors. The emerging application of microfluidics to on-body bioanalysis is a new strategy to establish systems for the continuous, real-time, and on-site determination of informative markers present in biofluids, such as sweat, interstitial fluid, blood, saliva, and tear. Electrochemical sensors are attractive to integrate with such microfluidics due to the possibility to be miniaturized. Moreover, on-body microfluidics coupled with bioelectronics enable smart integration with modern information and communication technology. This chapter discusses requirements and several challenges when developing on-body microfluidics such as difficulties in manipulating small sample volumes while maintaining mechanical flexibility, power-consumption efficiency, and simplicity of total automated systems. We describe key components, e.g., microchannels, microvalves, and electrochemical detectors, used in microfluidics. We also introduce representatives of advanced lab-on-a-body microfluidics combined with electrochemical sensors for biomedical applications. The chapter ends with a discussion of the potential trends of research in this field and opportunities. On-body microfluidics as modern total analysis devices will continue to bring several fascinating opportunities to the field of biomedical and translational research applications.
Collapse
Affiliation(s)
- Itthipon Jeerapan
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
| | - Chochanon Moonla
- School of Chemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand
| | - Panote Thavarungkul
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Proespichaya Kanatharana
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| |
Collapse
|
15
|
Yin M, Alexander Kim Z, Xu B. Micro/Nanofluidic‐Enabled Biomedical Devices: Integration of Structural Design and Manufacturing. ADVANCED NANOBIOMED RESEARCH 2021. [DOI: 10.1002/anbr.202100117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Affiliation(s)
- Mengtian Yin
- Department of Mechanical and Aerospace Engineering University of Virginia Charlottesville VA 22904 USA
| | - Zachary Alexander Kim
- Department of Mechanical and Aerospace Engineering University of Virginia Charlottesville VA 22904 USA
| | - Baoxing Xu
- Department of Mechanical and Aerospace Engineering University of Virginia Charlottesville VA 22904 USA
| |
Collapse
|
16
|
Gökçe F, Ravaynia PS, Modena MM, Hierlemann A. What is the future of electrical impedance spectroscopy in flow cytometry? BIOMICROFLUIDICS 2021; 15:061302. [PMID: 34917226 PMCID: PMC8651262 DOI: 10.1063/5.0073457] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 11/23/2021] [Indexed: 05/02/2023]
Abstract
More than 20 years ago, electrical impedance spectroscopy (EIS) was proposed as a potential characterization method for flow cytometry. As the setup is comparably simple and the method is label-free, EIS has attracted considerable interest from the research community as a potential alternative to standard optical methods, such as fluorescence-activated cell sorting (FACS). However, until today, FACS remains by and large the laboratory standard with highly developed capabilities and broad use in research and clinical settings. Nevertheless, can EIS still provide a complement or alternative to FACS in specific applications? In this Perspective, we will give an overview of the current state of the art of EIS in terms of technologies and capabilities. We will then describe recent advances in EIS-based flow cytometry, compare the performance to that of FACS methods, and discuss potential prospects of EIS in flow cytometry.
Collapse
Affiliation(s)
- Furkan Gökçe
- Bioengineering Laboratory, Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, 4058 Basel, Switzerland
| | - Paolo S. Ravaynia
- Bioengineering Laboratory, Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, 4058 Basel, Switzerland
| | - Mario M. Modena
- Bioengineering Laboratory, Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, 4058 Basel, Switzerland
| | - Andreas Hierlemann
- Bioengineering Laboratory, Department of Biosystems Science and Engineering, ETH Zürich, Mattenstrasse 26, 4058 Basel, Switzerland
| |
Collapse
|
17
|
Carminati M, Scandurra G. Impact and trends in embedding field programmable gate arrays and microcontrollers in scientific instrumentation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:091501. [PMID: 34598486 DOI: 10.1063/5.0050999] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Accepted: 08/16/2021] [Indexed: 06/13/2023]
Abstract
Microcontrollers and field-programmable gate arrays have been largely leveraged in scientific instrumentation since decades. Recent advancements in the performance of these programmable digital devices, with hundreds of I/O pins, up to millions of logic cells, >10 Gb/s connectivity, and hundreds of MHz multiple clocks, have been accelerating this trend, extending the range of functions. The diversification of devices from very low-cost 8-bit microcontrollers up to 32-bit ARM-based ones and a system of chip combining programmable logic with processors make them ubiquitous in modern electronic systems, addressing diverse challenges from ultra-low power operation, with sub-µA quiescent current in sleep mode for portable and Internet of Things applications, to high-performance computing, such as in machine vision. In this Review, the main motivations (compactness, re-configurability, parallelization, low latency for sub-ns timing, and real-time control), the possible approaches of the adoption of embedded devices, and the achievable performances are discussed. Relevant examples of applications in opto-electronics, physics experiments, impedance, vibration, and temperature sensing from the recent literature are also reviewed. From this bird-eye view, key paradigms emerge, such as the blurring of boundaries between digital platforms and the pervasiveness of machine learning algorithms, significantly fostered by the possibility to be run in embedded devices for distributing intelligence in the environment.
Collapse
Affiliation(s)
- M Carminati
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano 20133, Italy
| | - G Scandurra
- Dipartimento di Ingegneria, Università degli Studi di Messina, Messina 98166, Italy
| |
Collapse
|
18
|
Dieujuste D, Qiang Y, Du E. A portable impedance microflow cytometer for measuring cellular response to hypoxia. Biotechnol Bioeng 2021; 118:4041-4051. [PMID: 34232511 DOI: 10.1002/bit.27879] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 06/04/2021] [Accepted: 06/24/2021] [Indexed: 01/02/2023]
Abstract
This article presents the development and testing of a low-cost (<$60), portable, electrical impedance-based microflow cytometer for single-cell analysis under a controlled oxygen microenvironment. The system is based on an AD5933 impedance analyzer chip, a microfluidic chip, and an Arduino microcontroller operated by a custom Android application. A representative case study on human red blood cells (RBCs) affected by sickle cell disease is conducted to demonstrate the capability of the cytometry system. Impedance values of sickle blood samples exhibit remarkable deviations from the common reference line obtained from two normal blood samples. Such deviation is quantified by a conformity score, which allows for the measurement of intrapatient and interpatient variations of sickle cell disease. A low conformity score under oxygenated conditions or drastically different conformity scores between oxygenated and deoxygenated conditions can be used to differentiate a sickle blood sample from normal. Furthermore, an equivalent circuit model of a suspended biological cell is used to interpret the electrical impedance of single flowing RBCs. In response to hypoxia treatment, all samples, regardless of disease state, exhibit significant changes in at least one single-cell electrical property, that is, cytoplasmic resistance and membrane capacitance. The overall response to hypoxia is less in normal cells than those affected by sickle cell disease, where the change in membrane capacitance varies from -23% to seven times as compared with -17% in normal cells. The results reported in this article suggest that the developed method of testing demonstrates the potential application for a low-cost screening technique for sickle cell disease and other diseases in the field and low-resource settings. The developed system and methodology can be extended to analyze cellular response to hypoxia in other cell types.
Collapse
Affiliation(s)
- Darryl Dieujuste
- Department of Ocean and Mechanical Engineering, and the Department of Biological Sciences, Florida Atlantic University, Boca Raton, Florida, USA
| | - Yuhao Qiang
- Department of Ocean and Mechanical Engineering, and the Department of Biological Sciences, Florida Atlantic University, Boca Raton, Florida, USA
| | - E Du
- Department of Ocean and Mechanical Engineering, and the Department of Biological Sciences, Florida Atlantic University, Boca Raton, Florida, USA
| |
Collapse
|
19
|
Multi-frequency impedance sensing for detection and sizing of DNA fragments. Sci Rep 2021; 11:6490. [PMID: 33753781 PMCID: PMC7985362 DOI: 10.1038/s41598-021-85755-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 01/11/2021] [Indexed: 01/31/2023] Open
Abstract
Electronic biosensors for DNA detection typically utilize immobilized oligonucleotide probes on a signal transducer, which outputs an electronic signal when target molecules bind to probes. However, limitation in probe selectivity and variable levels of non-target material in complex biological samples can lead to nonspecific binding and reduced sensitivity. Here we introduce the integration of 2.8 μm paramagnetic beads with DNA fragments. We apply a custom-made microfluidic chip to detect DNA molecules bound to beads by measuring Impedance Peak Response (IPR) at multiple frequencies. Technical and analytical performance was evaluated using beads containing purified Polymerase Chain Reaction (PCR) products of different lengths (157, 300, 613 bp) with DNA concentration ranging from 0.039 amol to 7.8 fmol. Multi-frequency IPR correlated positively with DNA amounts and was used to calculate a DNA quantification score. The minimum DNA amount of a 300 bp fragment coupled on beads that could be robustly detected was 0.0039 fmol (1.54 fg or 4750 copies/bead). Additionally, our approach allowed distinguishing beads with similar molar concentration DNA fragments of different lengths. Using this impedance sensor, purified PCR products could be analyzed within ten minutes to determine DNA fragment length and quantity based on comparison to a known DNA standard.
Collapse
|
20
|
Tayyab M, Sami MA, Raji H, Mushnoori S, Javanmard M. Potential Microfluidic Devices for COVID-19 Antibody Detection at Point-of-Care (POC): A Review. IEEE SENSORS JOURNAL 2021; 21:4007-4017. [PMID: 37974932 PMCID: PMC8768978 DOI: 10.1109/jsen.2020.3034892] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 10/20/2020] [Accepted: 10/20/2020] [Indexed: 11/19/2023]
Abstract
COVID-19 has been declared a global pandemic which has brought the world economy and the society to a standstill. The current emphasis of testing is on detection of genetic material of SARS-CoV-2. Such tests are useful for assessing the current state of a subject: Infected or not infected. In addition to such tests, antibody testing is necessary to stratify the population into three groups: never exposed, infected, and immune. Such a stratification is necessary for safely reopening the society and remobilizing the economy. The aim of this review article is to inform the audience of the current diagnostic and surveillance technologies that are being employed for the detection of SARS-CoV-2 antibodies along with their shortcomings, and to highlight microfluidic sensors and devices that show promise of being commercialized for detection and quantification of SARS-CoV-2 antibodies in low-resource and Point-of-Care (POC) settings.
Collapse
Affiliation(s)
- Muhammad Tayyab
- Department of Electrical and Computer EngineeringRutgers UniversityPiscatawayNJ08854USA
| | - Muhammad Ahsan Sami
- Department of Electrical and Computer EngineeringRutgers UniversityPiscatawayNJ08854USA
| | - Hassan Raji
- Department of Electrical and Computer EngineeringRutgers UniversityPiscatawayNJ08854USA
| | - Srinivas Mushnoori
- Department of Chemical and Biochemical EngineeringRutgers UniversityPiscatawayNJ08854USA
| | - Mehdi Javanmard
- Department of Electrical and Computer EngineeringRutgers UniversityPiscatawayNJ08854USA
| |
Collapse
|
21
|
Honrado C, Bisegna P, Swami NS, Caselli F. Single-cell microfluidic impedance cytometry: from raw signals to cell phenotypes using data analytics. LAB ON A CHIP 2021; 21:22-54. [PMID: 33331376 PMCID: PMC7909465 DOI: 10.1039/d0lc00840k] [Citation(s) in RCA: 79] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The biophysical analysis of single-cells by microfluidic impedance cytometry is emerging as a label-free and high-throughput means to stratify the heterogeneity of cellular systems based on their electrophysiology. Emerging applications range from fundamental life-science and drug assessment research to point-of-care diagnostics and precision medicine. Recently, novel chip designs and data analytic strategies are laying the foundation for multiparametric cell characterization and subpopulation distinction, which are essential to understand biological function, follow disease progression and monitor cell behaviour in microsystems. In this tutorial review, we present a comparative survey of the approaches to elucidate cellular and subcellular features from impedance cytometry data, covering the related subjects of device design, data analytics (i.e., signal processing, dielectric modelling, population clustering), and phenotyping applications. We give special emphasis to the exciting recent developments of the technique (timeframe 2017-2020) and provide our perspective on future challenges and directions. Its synergistic application with microfluidic separation, sensor science and machine learning can form an essential toolkit for label-free quantification and isolation of subpopulations to stratify heterogeneous biosystems.
Collapse
Affiliation(s)
- Carlos Honrado
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA.
| | | | | | | |
Collapse
|
22
|
Xie P, Song N, Shen W, Allen M, Javanmard M. A ten-minute, single step, label-free, sample-to-answer assay for qualitative detection of cytokines in serum at femtomolar levels. Biomed Microdevices 2020; 22:73. [PMID: 33037941 DOI: 10.1007/s10544-020-00525-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2020] [Indexed: 10/23/2022]
Abstract
Label-free electronic affinity based immuno-sensing is an attractive candidate as a platform technology for analyzing biomarkers due to the ease of miniaturization and minimal use of reagents. Electronic based sensing approaches, however, have lagged behind their optical counterparts in terms of detection limit, selectivity, and reliability. Also, the matrix dependent nature of electronic sensing modalities makes difficult the analysis of biomarkers in high salt concentration samples such as serum due to charge screening. We present a novel sensing platform, the micro-well sensor, that works by functionalizing nanoscale volume wells with antibodies and monitoring the impedance change inside the wells due binding of target protein. This detection modality is advantageous to many label-free electronic sensors in that signal power scales with increase in salt concentration, thus improving the sensitivity of the platform. We demonstrate rapid label-free qualitative detection of cytokines within ten minutes at femtoMolar concentrations and a dynamic range of 3 orders of magnitude in serum samples. We describe the design, fabrication, and characterization of the micro-well sensor in serum samples using inflammatory protein biomarkers.
Collapse
Affiliation(s)
| | - Naixin Song
- University of Pennsylvania, Philadelphia, PA, USA
| | - Wen Shen
- University of Pennsylvania, Philadelphia, PA, USA
| | - Mark Allen
- University of Pennsylvania, Philadelphia, PA, USA
| | | |
Collapse
|
23
|
Honrado C, McGrath JS, Reale R, Bisegna P, Swami NS, Caselli F. A neural network approach for real-time particle/cell characterization in microfluidic impedance cytometry. Anal Bioanal Chem 2020; 412:3835-3845. [PMID: 32189012 DOI: 10.1007/s00216-020-02497-9] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 01/30/2020] [Accepted: 02/06/2020] [Indexed: 11/26/2022]
Abstract
Microfluidic applications such as active particle sorting or selective enrichment require particle classification techniques that are capable of working in real time. In this paper, we explore the use of neural networks for fast label-free particle characterization during microfluidic impedance cytometry. A recurrent neural network is designed to process data from a novel impedance chip layout for enabling real-time multiparametric analysis of the measured impedance data streams. As demonstrated with both synthetic and experimental datasets, the trained network is able to characterize with good accuracy size, velocity, and cross-sectional position of beads, red blood cells, and yeasts, with a unitary prediction time of 0.4 ms. The proposed approach can be extended to other device designs and cell types for electrical parameter extraction. This combination of microfluidic impedance cytometry and machine learning can serve as a stepping stone to real-time single-cell analysis and sorting. Graphical Abstract.
Collapse
Affiliation(s)
- Carlos Honrado
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA
| | - John S McGrath
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA
| | - Riccardo Reale
- Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, Via del Politecnico 1, 00133, Rome, Italy
| | - Paolo Bisegna
- Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, Via del Politecnico 1, 00133, Rome, Italy
| | - Nathan S Swami
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, 22904, USA.
| | - Frederica Caselli
- Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, Via del Politecnico 1, 00133, Rome, Italy.
| |
Collapse
|
24
|
Zhang S, Li Z, Wei Q. Smartphone-based cytometric biosensors for point-of-care cellular diagnostics. NANOTECHNOLOGY AND PRECISION ENGINEERING 2020. [DOI: 10.1016/j.npe.2019.12.004] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
25
|
Rapid Assessment of Surface Markers on Cancer Cells Using Immuno-Magnetic Separation and Multi-frequency Impedance Cytometry for Targeted Therapy. Sci Rep 2020; 10:3015. [PMID: 32080205 PMCID: PMC7033175 DOI: 10.1038/s41598-020-57540-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 12/06/2019] [Indexed: 12/29/2022] Open
Abstract
The rapid qualitative assessment of surface markers on cancer cells can allow for point-of-care prediction of patient response to various cancer drugs. Preclinical studies targeting cells with an antibody to "activated" matriptase conjugated to a potent toxin show promise as a selective treatment for a variety of solid tumors. In this paper, we implemented a novel technique for electrical detection of proteins on surfaces of cancer cells using multi-frequency microfluidic impedance cytometry. The biosensor, consists of two gold microelectrodes on a glass substrate embedded in a PDMS microfluidic channel, is used in conjugation with immuno-magnetic separation of cancer cells, and is capable of differentiating between bare magnetic beads, cancer cells and bead-cell aggregates based on their various impedance and frequency responses. We demonstrated proof-of-concept based on detection of "activated" matriptase proteins on the surface of cultured Mantle cells.
Collapse
|
26
|
Sui J, Xie P, Lin Z, Javanmard M. Electronic classification of barcoded particles for multiplexed detection using supervised machine learning analysis. Talanta 2020; 215:120791. [PMID: 32312428 DOI: 10.1016/j.talanta.2020.120791] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 01/08/2020] [Accepted: 01/28/2020] [Indexed: 01/29/2023]
Abstract
Wearable biosensors are of great interest in recent years due to their potential in health related applications. Multiplex biomarker analysis is needed in wearable devices to improve the sensitivity and reliability. Electronic barcoding of micro-particles has the possibility to enable multiplexed biomarker analysis. Compared with traditional optical and plasmonic methods for barcoding, electronically barcoded particles can be classified using ultra-compact electronic readout platforms. Nano-electronic barcoding works by depositing a thin layer of oxide on the top half of a micro-particle. The thickness and dielectric property of the oxide layer can be tuned to modulate the frequency dependent impedance signature of the particles. A one to one correspondence between a target biomarker and each barcoded particle can potentially be established using this technique. The barcoded particles could be tested with wearable devices to enable multiplex analysis for portable point-of-care diagnostics and real-time monitoring. In this work, we fabricated nine barcoded particles by forming oxide layers of different thicknesses and different dielectric materials using atomic layer deposition and assessed the ability to accurately classify particle barcodes using multi-frequency impedance cytometry in conjunction with supervised machine learning.
Collapse
Affiliation(s)
- Jianye Sui
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA
| | - Pengfei Xie
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA
| | - Zhongtian Lin
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA
| | - Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.
| |
Collapse
|
27
|
Electrical impedance as an indicator of microalgal cell health. Sci Rep 2020; 10:1251. [PMID: 31988339 PMCID: PMC6985174 DOI: 10.1038/s41598-020-57541-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 12/12/2019] [Indexed: 11/09/2022] Open
Abstract
Separating specific cell phenotypes from a heterotypic mixture is a critical step in many research projects. Traditional methods usually require a large sample volume and a complex preparation process that may alter cell property during the sorting process. Here we present the use of electrical impedance as an indicator of cell health and for identifying specific microalgal phenotypes. We developed a microfluidic platform for measuring electrical impedance at different frequencies using the bacterium-sized green alga Picochlorum SE3. The cells were cultured under different salinity conditions and sampled at four different time points. Our results demonstrate the utility of electrical impedance as an indicator of cell phenotype by providing results that are consistent with known changes in cell size and physiology. Outliers in the cell data distribution are particularly useful because they represent phenotypes that have the ability to maintain size and/or membrane ionic permeability under prolonged salt stress. This suggests that our device can be used to identify and sort desired (e.g., experimentally evolved, mutant) cell phenotypes based on their electrical impedance properties.
Collapse
|
28
|
Qureshi A, Niazi JH. Biosensors for detecting viral and bacterial infections using host biomarkers: a review. Analyst 2020; 145:7825-7848. [DOI: 10.1039/d0an00896f] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A schematic diagram showing multiple modes of biosensing platforms for the diagnosis of bacterial or viral infections.
Collapse
Affiliation(s)
- Anjum Qureshi
- Sabanci University
- SUNUM Nanotechnology Research and Application Center
- Tuzla 34956
- Turkey
| | - Javed H. Niazi
- Sabanci University
- SUNUM Nanotechnology Research and Application Center
- Tuzla 34956
- Turkey
| |
Collapse
|
29
|
Zhang Z, Azizi M, Lee M, Davidowsky P, Lawrence P, Abbaspourrad A. A versatile, cost-effective, and flexible wearable biosensor for in situ and ex situ sweat analysis, and personalized nutrition assessment. LAB ON A CHIP 2019; 19:3448-3460. [PMID: 31498355 DOI: 10.1039/c9lc00734b] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Point-of-care (POC) diagnostics have shown excellent potential in rapid biological analysis and health/disease monitoring. Here, we introduce a versatile, cost-effective, flexible, and wearable POC biomarker patch for effective sweat collection and health monitoring. We design and fabricate channels/patterns on filter paper using wax printing technology, which can direct sweat to collection and biomarker detection zones on the proposed platform. The detection zones are designed to measure the amount of collected sweat, in addition to measuring the sweat pH, and glucose (a potential diabetic biomarker), and lactate concentrations. It is significantly challenging to measure glucose in human sweat by colorimetric methods due to the extremely low glucose levels found in this medium. However, we overcame this issue by effectively engineering our wearable biosensor for optimal intake, storage, and evaporation of sweat. Our design concentrates the colorant (indicator) into a small detection zone and significantly increases the sensitivity for the sweat glucose sensing reactions. The device can thus detect glucose in physiological glucose concentration range of 50-300 μM. This cost-effective and wearable biosensor can provide instant in situ quantitative results for targets of interest, such as glucose, pH, and lactate, when coupled with the imaging and computing functionalities of smartphones. Meanwhile, it is also feasible to extract the air-dried sweat from the storage zone for further ex situ measurements of a broader portfolio of biomarkers, leading to applications of our wearable biosensor in personalized nutrition and medicine.
Collapse
Affiliation(s)
- Zhong Zhang
- Department of Food Science, College of Agriculture and Life Sciences, Cornell University, Ithaca 14853, NY, USA.
| | | | | | | | | | | |
Collapse
|
30
|
Zhang Y, Chen Y, Man T, Huang D, Li X, Zhu H, Li Z. High resolution non-invasive intraocular pressure monitoring by use of graphene woven fabrics on contact lens. MICROSYSTEMS & NANOENGINEERING 2019; 5:39. [PMID: 31636929 PMCID: PMC6799840 DOI: 10.1038/s41378-019-0078-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2018] [Revised: 04/18/2019] [Accepted: 05/28/2019] [Indexed: 05/04/2023]
Abstract
Monitoring intracorporal pressures are important for health care and diagnosis. In this work, a contact lens tonometer employing graphene woven fabrics (GWFs), which indicate great sensibility of resistance to strain, flexibility, stretchability, transparency, and biocompatibility, is proposed for real-time monitoring intraocular pressure (IOP) with high resolution. The mechanical properties of the device during the deformation were analyzed, and the sensitivity of the fabricated device was tested on a mimic human eyeball. In vitro experiments on porcine eyes were executed to test the effectiveness of the device. The change rate of resistance under different IOP was tested. Also, the relationship between the current changes and IOP variation when keeping the voltage constant for different devices was obtained. The contact lens tonometers with GWFs as high-resolution sensing element have shown a promising prospective to realize the low-cost disposable sensing contact lens with lower power.
Collapse
Affiliation(s)
- Yushi Zhang
- 1School of Information Engineering, Minzu University of China, 100081 Beijing, China
- 2National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, 100871 Beijing, China
| | - Yufeng Chen
- 2National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, 100871 Beijing, China
| | - Tianxing Man
- 2National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, 100871 Beijing, China
| | - Dong Huang
- 2National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, 100871 Beijing, China
| | - Xiao Li
- 3Key Laboratory for Advanced Manufacturing by Materials Processing Technology, Department of Mechanical Engineering, Tsinghua University, 100084 Beijing, China
| | - Hongwei Zhu
- 3Key Laboratory for Advanced Manufacturing by Materials Processing Technology, Department of Mechanical Engineering, Tsinghua University, 100084 Beijing, China
- 4Center for Nano and Micro Mechanics (CNMM), Tsinghua University, 100084 Beijing, China
| | - Zhihong Li
- 2National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, 100871 Beijing, China
- 4Center for Nano and Micro Mechanics (CNMM), Tsinghua University, 100084 Beijing, China
| |
Collapse
|
31
|
Reale R, De Ninno A, Businaro L, Bisegna P, Caselli F. High-throughput electrical position detection of single flowing particles/cells with non-spherical shape. LAB ON A CHIP 2019; 19:1818-1827. [PMID: 30997463 DOI: 10.1039/c9lc00071b] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We present an innovative impedance cytometer for the measurement of the cross-sectional position of single particles or cells flowing in a microchannel. As predicted by numerical simulations and experimentally validated, the proposed approach is applicable to particles/cells with either spherical or non-spherical shape. In particular, the optics-free high-throughput position detection of individual flowing red blood cells (RBCs) is demonstrated and applied to monitor RBCs hydrodynamic focusing under different sheath flow conditions. Moreover, the device provides multiparametric information useful for lab-on-a-chip applications, including particle inter-arrival times and velocity profile, as well as RBCs mean corpuscular volume, distribution width and electrical opacity.
Collapse
Affiliation(s)
- Riccardo Reale
- Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, 00133 Rome, Italy.
| | | | | | | | | |
Collapse
|
32
|
Meng L, Turner APF, Mak WC. Soft and flexible material-based affinity sensors. Biotechnol Adv 2019; 39:107398. [PMID: 31071431 DOI: 10.1016/j.biotechadv.2019.05.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Revised: 05/01/2019] [Accepted: 05/04/2019] [Indexed: 01/11/2023]
Abstract
Recent advances in biosensors and point-of-care (PoC) devices are poised to change and expand the delivery of diagnostics from conventional lateral-flow assays and test strips that dominate the market currently, to newly emerging wearable and implantable devices that can provide continuous monitoring. Soft and flexible materials are playing a key role in propelling these trends towards real-time and remote health monitoring. Affinity biosensors have the capability to provide for diagnosis and monitoring of cancerous, cardiovascular, infectious and genetic diseases by the detection of biomarkers using affinity interactions. This review tracks the evolution of affinity sensors from conventional lateral-flow test strips to wearable/implantable devices enabled by soft and flexible materials. Initially, we highlight conventional affinity sensors exploiting membrane and paper materials which have been so successfully applied in point-of-care tests, such as lateral-flow immunoassay strips and emerging microfluidic paper-based devices. We then turn our attention to the multifarious polymer designs that provide both the base materials for sensor designs, such as PDMS, and more advanced functionalised materials that are capable of both recognition and transduction, such as conducting and molecularly imprinted polymers. The subsequent content discusses wearable soft and flexible material-based affinity sensors, classified as flexible and skin-mountable, textile materials-based and contact lens-based affinity sensors. In the final sections, we explore the possibilities for implantable/injectable soft and flexible material-based affinity sensors, including hydrogels, microencapsulated sensors and optical fibers. This area is truly a work in progress and we trust that this review will help pull together the many technological streams that are contributing to the field.
Collapse
Affiliation(s)
- Lingyin Meng
- Biosensors and Bioelectronics Centre, Department of Physics, Chemistry and Biology, Linköping University, SE-581 83 Linköping, Sweden
| | | | - Wing Cheung Mak
- Biosensors and Bioelectronics Centre, Department of Physics, Chemistry and Biology, Linköping University, SE-581 83 Linköping, Sweden.
| |
Collapse
|
33
|
Shaikh SF, Mazo-Mantilla HF, Qaiser N, Khan SM, Nassar JM, Geraldi NR, Duarte CM, Hussain MM. Noninvasive Featherlight Wearable Compliant "Marine Skin": Standalone Multisensory System for Deep-Sea Environmental Monitoring. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1804385. [PMID: 30706612 DOI: 10.1002/smll.201804385] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 12/09/2018] [Indexed: 06/09/2023]
Abstract
Advances in marine research to understand environmental change and its effect on marine ecosystems rely on gathering data on species physiology, their habitat, and their mobility patterns using heavy and invasive biologgers and sensory telemetric networks. In the past, a lightweight (6 g) compliant environmental monitoring system: Marine Skin was demonstrated. In this paper, an enhanced version of that skin with improved functionalities (500-1500% enhanced sensitivity), packaging, and most importantly its endurance at a depth of 2 km in the highly saline Red Sea water for four consecutive weeks is reported. A unique noninvasive approach for attachment of the sensor by designing a wearable, stretchable jacket (bracelet) that can adhere to any species irrespective of their skin type is also illustrated. The wearable featherlight (<0.5 g in air, 3 g with jacket) gadget is deployed on Barramundi, Seabream, and common goldfish to demonstrate the noninvasive and effective attachment strategy on different species of variable sizes which does not hinder the animals' natural movement or behavior.
Collapse
Affiliation(s)
- Sohail F Shaikh
- mmh Labs, Electrical Engineering, Computer Electrical Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Harold F Mazo-Mantilla
- mmh Labs, Electrical Engineering, Computer Electrical Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Nadeem Qaiser
- mmh Labs, Electrical Engineering, Computer Electrical Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Sherjeel M Khan
- mmh Labs, Electrical Engineering, Computer Electrical Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Joanna M Nassar
- California Institute of Technology, Pasadena, CA, 91125, USA
| | - Nathan R Geraldi
- Red Sea Research Center (RSRC), Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Carlos M Duarte
- Red Sea Research Center (RSRC), Division of Biological and Environmental Sciences and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Muhammad M Hussain
- mmh Labs, Electrical Engineering, Computer Electrical Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| |
Collapse
|
34
|
Javanmard M. Lab-on-a-chip technologies for diagnosis and monitoring of airway inflammation. J Allergy Clin Immunol 2018; 143:542-544. [PMID: 30447243 DOI: 10.1016/j.jaci.2018.10.051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Revised: 10/02/2018] [Accepted: 10/11/2018] [Indexed: 02/02/2023]
Affiliation(s)
- Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, NJ.
| |
Collapse
|