1
|
Niederhoffer T, Vanhoestenberghe A, Lancashire HT. Methods of poly(3,4)-ethylenedioxithiophene (PEDOT) electrodeposition on metal electrodes for neural stimulation and recording. J Neural Eng 2023; 20. [PMID: 36603213 DOI: 10.1088/1741-2552/acb084] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 01/05/2023] [Indexed: 01/06/2023]
Abstract
Conductive polymers are of great interest in the field of neural electrodes because of their potential to improve the interfacial properties of electrodes. In particular, the conductive polymer poly (3,4)-ethylenedioxithiophene (PEDOT) has been widely studied for neural applications.Objective:This review compares methods for electrodeposition of PEDOT on metal neural electrodes, and analyses the effects of deposition methods on morphology and electrochemical performance.Approach:Electrochemical performances were analysed against several deposition method choices, including deposition charge density and co-ion, and correlations were explained to morphological and structural arguments as well as characterisation methods choices.Main results:Coating thickness and charge storage capacity are positively correlated with PEDOT electrodeposition charge density. We also show that PEDOT coated electrode impedance at 1 kHz, the only consistently reported impedance quantity, is strongly dependent upon electrode radius across a wide range of studies, because PEDOT coatings reduces the reactance of the complex impedance, conferring a more resistive behaviour to electrodes (at 1 kHz) dominated by the solution resistance and electrode geometry. This review also summarises how PEDOT co-ion choice affects coating structure and morphology and shows that co-ions notably influence the charge injection limit but have a limited influence on charge storage capacity and impedance. Finally we discuss the possible influence of characterisation methods to assess the robustness of comparisons between published results using different methods of characterisation.Significance:This review aims to serve as a common basis for researchers working with PEDOT by showing the effects of deposition methods on electrochemical performance, and aims to set a standard for accurate and uniform reporting of methods.
Collapse
Affiliation(s)
- Thomas Niederhoffer
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| | - Anne Vanhoestenberghe
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Henry T Lancashire
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| |
Collapse
|
2
|
Sheth M, Esfandiari L. Bioelectric Dysregulation in Cancer Initiation, Promotion, and Progression. Front Oncol 2022; 12:846917. [PMID: 35359398 PMCID: PMC8964134 DOI: 10.3389/fonc.2022.846917] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 02/21/2022] [Indexed: 12/12/2022] Open
Abstract
Cancer is primarily a disease of dysregulation – both at the genetic level and at the tissue organization level. One way that tissue organization is dysregulated is by changes in the bioelectric regulation of cell signaling pathways. At the basis of bioelectricity lies the cellular membrane potential or Vmem, an intrinsic property associated with any cell. The bioelectric state of cancer cells is different from that of healthy cells, causing a disruption in the cellular signaling pathways. This disruption or dysregulation affects all three processes of carcinogenesis – initiation, promotion, and progression. Another mechanism that facilitates the homeostasis of cell signaling pathways is the production of extracellular vesicles (EVs) by cells. EVs also play a role in carcinogenesis by mediating cellular communication within the tumor microenvironment (TME). Furthermore, the production and release of EVs is altered in cancer. To this end, the change in cell electrical state and in EV production are responsible for the bioelectric dysregulation which occurs during cancer. This paper reviews the bioelectric dysregulation associated with carcinogenesis, including the TME and metastasis. We also look at the major ion channels associated with cancer and current technologies and tools used to detect and manipulate bioelectric properties of cells.
Collapse
Affiliation(s)
- Maulee Sheth
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
| | - Leyla Esfandiari
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
- Department of Electrical Engineering and Computer Science, University of Cincinnati, Cincinnati, OH, United States
- Department of Environmental and Public Health Sciences, University of Cincinnati, Cincinnati, OH, United States
- *Correspondence: Leyla Esfandiari,
| |
Collapse
|
3
|
Pitsalidis C, Pappa AM, Boys AJ, Fu Y, Moysidou CM, van Niekerk D, Saez J, Savva A, Iandolo D, Owens RM. Organic Bioelectronics for In Vitro Systems. Chem Rev 2021; 122:4700-4790. [PMID: 34910876 DOI: 10.1021/acs.chemrev.1c00539] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Bioelectronics have made strides in improving clinical diagnostics and precision medicine. The potential of bioelectronics for bidirectional interfacing with biology through continuous, label-free monitoring on one side and precise control of biological activity on the other has extended their application scope to in vitro systems. The advent of microfluidics and the considerable advances in reliability and complexity of in vitro models promise to eventually significantly reduce or replace animal studies, currently the gold standard in drug discovery and toxicology testing. Bioelectronics are anticipated to play a major role in this transition offering a much needed technology to push forward the drug discovery paradigm. Organic electronic materials, notably conjugated polymers, having demonstrated technological maturity in fields such as solar cells and light emitting diodes given their outstanding characteristics and versatility in processing, are the obvious route forward for bioelectronics due to their biomimetic nature, among other merits. This review highlights the advances in conjugated polymers for interfacing with biological tissue in vitro, aiming ultimately to develop next generation in vitro systems. We showcase in vitro interfacing across multiple length scales, involving biological models of varying complexity, from cell components to complex 3D cell cultures. The state of the art, the possibilities, and the challenges of conjugated polymers toward clinical translation of in vitro systems are also discussed throughout.
Collapse
Affiliation(s)
- Charalampos Pitsalidis
- Department of Physics, Khalifa University of Science and Technology, P.O. Box 127788, Abu Dhabi 127788, UAE.,Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Anna-Maria Pappa
- Department of Biomedical Engineering, Khalifa University of Science and Technology, P.O. Box 127788, Abu Dhabi 127788, UAE
| | - Alexander J Boys
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Ying Fu
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K.,Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, Glasgow G1 1RD, U.K
| | - Chrysanthi-Maria Moysidou
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Douglas van Niekerk
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Janire Saez
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K.,Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Avenida Miguel de Unamuno, 3, 01006 Vitoria-Gasteiz, Spain.,Ikerbasque, Basque Foundation for Science, E-48011 Bilbao, Spain
| | - Achilleas Savva
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Donata Iandolo
- INSERM, U1059 Sainbiose, Université Jean Monnet, Mines Saint-Étienne, Université de Lyon, 42023 Saint-Étienne, France
| | - Róisín M Owens
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| |
Collapse
|
4
|
Kandel R, Jang SR, Shrestha S, Lee SY, Shrestha BK, Park CH, Kim CS. Biomimetic Cell-Substrate of Chitosan-Cross-linked Polyaniline Patterning on TiO 2 Nanotubes Enables hBM-MSCs to Differentiate the Osteoblast Cell Type. ACS APPLIED MATERIALS & INTERFACES 2021; 13:47100-47117. [PMID: 34579527 DOI: 10.1021/acsami.1c09778] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Titanium-based substrates are widely used in orthopedic treatments and hard tissue engineering. However, many of these titanium (Ti) substrates fail to interact properly between the cell-to-implant interface, which can lead to loosening and dislocation from the implant site. As a result, scaffold implant-associated complications and the need for multiple surgeries lead to an increased clinical burden. To address these challenges, we engineered osteoconductive and osteoinductive biosubstrates of chitosan (CS)-cross-linked polyaniline (PANI) nanonets coated on titanium nanotubes (TiO2NTs) in an attempt to mimic bone tissue's major extracellular matrix. Inspired by the architectural and tunable mechanical properties of such tissue, the TiO2NTs-PANI@CS-based biofilm conferred strong anticorrosion, the ability to nucleate hydroxyapatite nanoparticles, and excellent biocompatibility with human bone marrow-derived mesenchymal stem cells (hBM-MSCs). An in vitro study showed that the substrate-supported cell activities induced greater cell proliferation and differentiation compared to cell-TiO2NTs alone. Notably, the bone-related genes (collagen-I, OPN, OCN, and RUNX 2) were highly expressed within TiO2NTs-PANI@CS over a period of 14 days, indicating greater bone cell differentiation. These findings demonstrate that the in vitro functionality of the cells on the osteoinductive-like platform of TiO2NTs-PANI@CS improves the efficiency for osteoblastic cell regeneration and that the substrate potentially has utility in bone tissue engineering applications.
Collapse
Affiliation(s)
- Rupesh Kandel
- Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Se Rim Jang
- Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Sita Shrestha
- Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Seo Yeon Lee
- Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Bishnu Kumar Shrestha
- Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
- Regional Leading Research Center for Nanocarbon-Based Energy Materials and Application Technology, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Chan Hee Park
- Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
- Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
- Division of Mechanical Design Engineering, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| | - Cheol Sang Kim
- Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
- Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 561-756, Republic of Korea
- Division of Mechanical Design Engineering, Jeonbuk National University, Jeonju 561-756, Republic of Korea
| |
Collapse
|
5
|
Zozoulenko I, Franco-Gonzalez JF, Gueskine V, Mehandzhiyski A, Modarresi M, Rolland N, Tybrandt K. Electronic, Optical, Morphological, Transport, and Electrochemical Properties of PEDOT: A Theoretical Perspective. Macromolecules 2021. [DOI: 10.1021/acs.macromol.1c00444] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Igor Zozoulenko
- Laboratory of Organic Electronics, ITN, Linköping University, 60174 Norrköping, Sweden
| | | | - Viktor Gueskine
- Laboratory of Organic Electronics, ITN, Linköping University, 60174 Norrköping, Sweden
| | | | - Mohsen Modarresi
- Department of Physics, Ferdowsi University of Mashhad, Mashhad, PO Box 91775-1436, Iran
| | - Nicolas Rolland
- Laboratory of Organic Electronics, ITN, Linköping University, 60174 Norrköping, Sweden
| | - Klas Tybrandt
- Laboratory of Organic Electronics, ITN, Linköping University, 60174 Norrköping, Sweden
| |
Collapse
|
6
|
Gautam B, Ayalew H, Dhawan U, Aerathupalathu Janardhanan J, Yu H. Layer‐by‐layer assembly and electrically controlled disassembly of water‐soluble
Poly(3,4‐ethylenedioxythiophene)
derivatives for bioelectronic interface. J CHIN CHEM SOC-TAIP 2020. [DOI: 10.1002/jccs.202000146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Bhaskarchand Gautam
- Smart Organic Materials Laboratory Institute of Chemistry, Academia Sinica Nankang Taiwan
- Taiwan International Graduate Program (TIGP) Sustainable Chemical Science and Technology (SCST), Academia Sinica Taipei Taiwan
- Department of Applied Chemistry National Chiao Tung University Hsinchu Taiwan
| | - Hailemichael Ayalew
- Smart Organic Materials Laboratory Institute of Chemistry, Academia Sinica Nankang Taiwan
| | - Udesh Dhawan
- Smart Organic Materials Laboratory Institute of Chemistry, Academia Sinica Nankang Taiwan
| | - Jayakrishnan Aerathupalathu Janardhanan
- Smart Organic Materials Laboratory Institute of Chemistry, Academia Sinica Nankang Taiwan
- Taiwan International Graduate Program (TIGP) Sustainable Chemical Science and Technology (SCST), Academia Sinica Taipei Taiwan
- Department of Applied Chemistry National Chiao Tung University Hsinchu Taiwan
| | - Hsiao‐hua Yu
- Smart Organic Materials Laboratory Institute of Chemistry, Academia Sinica Nankang Taiwan
- Taiwan International Graduate Program (TIGP) Sustainable Chemical Science and Technology (SCST), Academia Sinica Taipei Taiwan
| |
Collapse
|
7
|
Li J, Chang X, Li S, Shrestha PK, Tan EK, Chu D. High-Resolution Electrochemical Transistors Defined by Mold-Guided Drying of PEDOT:PSS Liquid Suspension. ACS APPLIED ELECTRONIC MATERIALS 2020; 2:2611-2618. [PMID: 32879912 PMCID: PMC7450888 DOI: 10.1021/acsaelm.0c00491] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 07/31/2020] [Indexed: 06/11/2023]
Abstract
Ion-sensitive transistors with nanoscale or microscale dimensions are promising for high-resolution electrophysiological recording and sensing. Technology that can pattern polymer functional materials directly from a solution can effectively avoid any chemical damage induced by conventional lithography techniques. The application of a mold-guided drying technique to pattern PEDOT:PSS-based transistors with high resolution directly from the water-based suspension is presented in this paper. Gold electrodes with short channels were first defined by creating high-resolution polymer lines with mold-guided drying followed by pattern transfer through a lift-off process. Then, PEDOT:PSS lines were subsequently created through an identical mold-guided drying process on the predefined electrodes. Small-scale transistor devices with both shortened channel length and width exhibited a good high-frequency response because of the weak capacitive effect. This is particularly advantageous for electrochemical transistors since the use of conventional fabrication techniques is extremely challenging in this case. In addition, modified polymer chain alignment of the assembled PEDOT:PSS lines during the drying process was observed by optical and electrical measurement. The mold-guided drying technique has been proven to be a promising method to fabricate small-scale devices, especially for biological applications.
Collapse
Affiliation(s)
- Jin Li
- Centre
for Photonic Devices and Sensors, University
of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K.
| | - Xin Chang
- Centre
for Photonic Devices and Sensors, University
of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K.
| | - Shunpu Li
- Centre
for Photonic Devices and Sensors, University
of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K.
- College
of New Materials and New Energies, Shenzhen
Technology University, Shenzhen, 518118, China
| | - Pawan Kumar Shrestha
- Centre
for Photonic Devices and Sensors, University
of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K.
| | - Edward K.W. Tan
- Department
of Engineering, University of Cambridge, Cambridge, CB3 0FA, U.K.
| | - Daping Chu
- Centre
for Photonic Devices and Sensors, University
of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA, U.K.
| |
Collapse
|
8
|
Eickenscheidt M, Singler E, Stieglitz T. Pulsed electropolymerization of PEDOT enabling controlled branching. Polym J 2019. [DOI: 10.1038/s41428-019-0213-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
9
|
Abstract
Understanding the cellular basis of human health and disease requires the spatial resolution of microscopy and the molecular-level details provided by spectroscopy. This review highlights imaging methods at the intersection of microscopy and spectroscopy with applications in cell biology. Imaging methods are divided into three broad categories: fluorescence microscopy, label-free approaches, and imaging tools that can be applied to multiple imaging modalities. Just as these imaging methods allow researchers to address new biological questions, progress in biological sciences will drive the development of new imaging methods. We highlight four topics in cell biology that illustrate the need for new imaging tools: nanoparticle-cell interactions, intracellular redox chemistry, neuroscience, and the increasing use of spheroids and organoids. Overall, our goal is to provide a brief overview of individual imaging methods and highlight recent advances in the use of microscopy for cell biology.
Collapse
Affiliation(s)
- Joshua D Morris
- School of Science and Technology, Georgia Gwinnett College, Lawrenceville, Georgia 30043, USA
| | - Christine K Payne
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, USA;
| |
Collapse
|
10
|
Advances in materials for cellular applications (Review). Biointerphases 2019; 14:010801. [PMID: 30803241 DOI: 10.1116/1.5083803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The goal of this review is to highlight materials that show exciting promise for either entirely new cellular-level applications or new approaches to long-standing biological challenges. The authors start with two more established materials, graphene and carbon nanotubes, and then progress to conducting polymers, followed by an overview of the microresonators, nanowires, and spasers used as intracellular lasers. These materials provide new approaches to gene and drug delivery, cellular regeneration, mechanical sensing, imaging, and the modulation and recording of cellular activity. Of specific interest is the comparison of these materials with existing technologies, the method of cellular delivery, and the all-encompassing challenge of biocompatibility. Concluding remarks examine the extension of these materials from cellular-level experiments to in vivo applications, including the method of activation: light, electricity, and ultrasound. Overall, these materials and their associated applications illustrate the most recent advances in material-cell interactions.
Collapse
|
11
|
Molina BG, Cianga L, Bendrea AD, Cianga I, del Valle LJ, Estrany F, Alemán C, Armelin E. Amphiphilic polypyrrole-poly(Schiff base) copolymers with poly(ethylene glycol) side chains: synthesis, properties and applications. Polym Chem 2018. [DOI: 10.1039/c8py00762d] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
New amphiphilic poly(ethylene glycol) (PEG)-grafted random intrinsically conducting copolymers which combine three different functionalities have been engineered, prepared and characterized.
Collapse
Affiliation(s)
- Brenda G. Molina
- Departament d'Enginyeria Química
- EEBE
- Universitat Politècnica de Catalunya
- Barcelona
- Spain
| | - Luminita Cianga
- “Petru Poni” Institute of Macromolecular Chemistry
- Iasi
- Romania
| | | | - Ioan Cianga
- “Petru Poni” Institute of Macromolecular Chemistry
- Iasi
- Romania
| | - Luis J. del Valle
- Departament d'Enginyeria Química
- EEBE
- Universitat Politècnica de Catalunya
- Barcelona
- Spain
| | - Francesc Estrany
- Departament d'Enginyeria Química
- EEBE
- Universitat Politècnica de Catalunya
- Barcelona
- Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química
- EEBE
- Universitat Politècnica de Catalunya
- Barcelona
- Spain
| | - Elaine Armelin
- Departament d'Enginyeria Química
- EEBE
- Universitat Politècnica de Catalunya
- Barcelona
- Spain
| |
Collapse
|