1
|
Zhang H, Zhang W, Zuo Z, Yang J. Towards ultra-low-cost smartphone microscopy. Microsc Res Tech 2024; 87:1521-1533. [PMID: 38419399 DOI: 10.1002/jemt.24535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 12/17/2023] [Accepted: 02/14/2024] [Indexed: 03/02/2024]
Abstract
The outbreak of COVID-19 exposed the inadequacy of our technical tools for home health surveillance, and recent studies have shown the potential of smartphones as a universal optical microscopic imaging platform for such applications. However, most of them use laboratory-grade optomechanical components and transmitted illuminations to ensure focus tuning capability and imaging quality, which keeps the cost of the equipment high. Here, we propose an ultra-low-cost solution for smartphone microscopy. To realize focus tunability, we designed a seesaw-like structure capable of converting large displacements on one side into small displacements on the other (reduced to ∼9.1%), which leverages the intrinsic flexibility of 3D printing materials. We achieved a focus-tuning accuracy of ∼5 𝜇m, which is 40 times higher than the machining accuracy of the 3D-printed lens holder itself. For microscopic imaging, we used an off-the-shelf smartphone camera lens as the objective and the built-in flashlight as the illumination. To compensate for the resulting image quality degradation, we developed a learning-based image enhancement method. We used the CycleGAN architecture to establish the mapping from smartphone microscope images to benchtop microscope images without pairing. We verified the imaging performance on different biomedical samples. Except for the smartphone, we kept the full costs of the device under 4 USD. We think these efforts to lower the costs of smartphone microscopes will benefit their applications in various scenarios, such as point-of-care testing, on-site diagnosis, and home health surveillance. RESEARCH HIGHLIGHTS: We propose a solution for ultra-low-cost smartphone microscopy. Utilizing the flexibility of 3D-printed material, we can achieve focusing accuracy of ∼5 𝜇m. Such a low-cost device will benefit point-of-care diagnosis and home health surveillance.
Collapse
Affiliation(s)
- Haoran Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Weiyi Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zirui Zuo
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianlong Yang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Kim K, Lee WG. Portable, Automated and Deep-Learning-Enabled Microscopy for Smartphone-Tethered Optical Platform Towards Remote Homecare Diagnostics: A Review. SMALL METHODS 2023; 7:e2200979. [PMID: 36420919 DOI: 10.1002/smtd.202200979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 10/18/2022] [Indexed: 06/16/2023]
Abstract
Globally new pandemic diseases induce urgent demands for portable diagnostic systems to prevent and control infectious diseases. Smartphone-based portable diagnostic devices are significantly efficient tools to user-friendly connect personalized health conditions and collect valuable optical information for rapid diagnosis and biomedical research through at-home screening. Deep learning algorithms for portable microscopes also help to enhance diagnostic accuracy by reducing the imaging resolution gap between benchtop and portable microscopes. This review highlighted recent progress and continued efforts in a smartphone-tethered optical platform through portable, automated, and deep-learning-enabled microscopy for personalized diagnostics and remote monitoring. In detail, the optical platforms through smartphone-based microscopes and lens-free holographic microscopy are introduced, and deep learning-based portable microscopic imaging is explained to improve the image resolution and accuracy of diagnostics. The challenges and prospects of portable optical systems with microfluidic channels and a compact microscope to screen COVID-19 in the current pandemic are also discussed. It has been believed that this review offers a novel guide for rapid diagnosis, biomedical imaging, and digital healthcare with low cost and portability.
Collapse
Affiliation(s)
- Kisoo Kim
- Intelligent Optical Module Research Center, Korea Photonics Technology Institute (KOPTI), Buk-gu, Gwangju, 61007, Republic of Korea
| | - Won Gu Lee
- Department of Mechanical Engineering, Kyung Hee University, Yongin, 17104, Republic of Korea
| |
Collapse
|
3
|
Parween S, Asthana A, Nahar P. Fundamentals of Image-Based Assay (IBA) System for Affordable Point of Care Diagnostics. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
4
|
Sandmeyer A, Wang L, Hübner W, Müller M, Chen BK, Huser T. Cost-effective high-speed, three-dimensional live-cell imaging of HIV-1 transfer at the T cell virological synapse. iScience 2022; 25:105468. [PMID: 36388970 PMCID: PMC9663902 DOI: 10.1016/j.isci.2022.105468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 05/16/2022] [Accepted: 10/26/2022] [Indexed: 11/12/2022] Open
Abstract
The availability of cost-effective, highly portable, and easy to use high-resolution live-cell imaging systems could present a significant technological break-through in challenging environments, such as high-level biosafety laboratories or sites where new viral outbreaks are suspected. We describe and demonstrate a cost-effective high-speed fluorescence microscope enabling the live tracking of virus particles across virological synapses that form between infected and uninfected T cells. The dynamics of HIV-1 proteins studied at the cellular level and the formation of virological synapses in living T cells reveals mechanisms by which cell-cell interactions facilitate infection between immune cells. Dual-color 3D fluorescence deconvolution microscopy of HIV-1 particles at frames rates of 100 frames per second allows us to follow the transfer of HIV-1 particles across the T cell virological synapse between living T cells. We also confirm the successful transfer of virus by imaging T cell samples fixed at specific time points during cell-cell virus transfer by super-resolution structured illumination microscopy.
Collapse
Affiliation(s)
- Alice Sandmeyer
- Biomolecular Photonics, Faculty of Physics, Bielefeld University, 33615 Bielefeld, Germany
| | - Lili Wang
- Division of Infectious Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York City, NY 10029, USA
| | - Wolfgang Hübner
- Biomolecular Photonics, Faculty of Physics, Bielefeld University, 33615 Bielefeld, Germany
| | - Marcel Müller
- Biomolecular Photonics, Faculty of Physics, Bielefeld University, 33615 Bielefeld, Germany
| | - Benjamin K. Chen
- Division of Infectious Diseases, Department of Medicine, Icahn School of Medicine at Mount Sinai, New York City, NY 10029, USA
| | - Thomas Huser
- Biomolecular Photonics, Faculty of Physics, Bielefeld University, 33615 Bielefeld, Germany
| |
Collapse
|
5
|
Salido J, Bueno G, Ruiz‐Santaquiteria J, Cristobal G. A review on low-cost microscopes for Open Science. Microsc Res Tech 2022; 85:3270-3283. [PMID: 35879870 PMCID: PMC9796433 DOI: 10.1002/jemt.24200] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 06/21/2022] [Accepted: 06/28/2022] [Indexed: 01/01/2023]
Abstract
This article presents a review after an exhaustive search that yielded 23 works carried out in the last decade for the availability of optical microscopes with open hardware as a low-cost alternative to commercial systems. These works were developed with the aim of covering needs within several areas such as: Bio Sciences research in institutions with limited resources, diagnosis of diseases and health screenings in large populations in developing countries, and training in educational contexts with a need for high availability of equipment and low replacement cost. The analysis of the selected works allows us to classify the analyzed solutions into two main categories, for which their essential characteristics are enumerated: portable field microscopes and multipurpose automated microscopes. Moreover, this work includes a discussion on the degree of maturity of the solutions in terms of the adoption of practices aligned with the development of Open Science. RESEARCH HIGHLIGHTS: Concise review on low-cost microscopes for developing Open Science, exposing the role of smartphone-based microscopy. The work classifies microscopes in two main categories: (1) portable field microscopes, and (2) multipurpose automated microscopes.
Collapse
Affiliation(s)
- Jesus Salido
- VISILAB GroupUniversidad de Castilla‐La ManchaCiudad RealSpain
| | - Gloria Bueno
- VISILAB GroupUniversidad de Castilla‐La ManchaCiudad RealSpain
| | | | | |
Collapse
|
6
|
Multi-Mode Compact Microscopy for High-Contrast and High-Resolution Imaging. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We report a multi-mode compact microscope (MCM) for high-contrast and high-resolution imaging. The MCM consists of two LED illuminations, a magnification lens, a lift stage, and a housing with image processing and LED control boards. The MCM allows multi-modal imaging, including reflection, transmission, and higher magnification modes. The dual illuminations also provide high-contrast imaging of various targets such as biological samples and microcircuits. The high dynamic range (HDR) imaging reconstruction of MCM increases the dynamic range of the acquired images by 1.36 times. The microlens array (MLA)-assisted MCM also improves image resolution through the magnified virtual image of MLA. The MLA-assisted MCM successfully provides a clear, magnified image by integrating a pinhole mask to prevent image overlap without additional alignment. The magnification of MLA-assisted MCM was increased by 3.92 times compared with that of MCM, and the higher magnification mode demonstrates the image resolution of 2.46 μm. The compact portable microscope can provide a new platform for defect inspection or disease detection on site.
Collapse
|
7
|
Wincott M, Jefferson A, Dobbie IM, Booth MJ, Davis I, Parton RM. Democratising “Microscopi”: a 3D printed automated XYZT fluorescence imaging system for teaching, outreach and fieldwork. Wellcome Open Res 2022; 6:63. [PMID: 33977151 PMCID: PMC8082569 DOI: 10.12688/wellcomeopenres.16536.2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/18/2022] [Indexed: 11/20/2022] Open
Abstract
Commercial fluorescence microscope stands and fully automated XYZt fluorescence imaging systems are generally beyond the limited budgets available for teaching and outreach. We have addressed this problem by developing “Microscopi”, an accessible, affordable, DIY automated imaging system that is built from 3D printed and commodity off-the-shelf hardware, including electro-mechanical, computer and optical components. Our design features automated sample navigation and image capture with a simple web-based graphical user interface, accessible with a tablet or other mobile device. The light path can easily be switched between different imaging modalities. The open source Python-based control software allows the hardware to be driven as an integrated imaging system. Furthermore, the microscope is fully customisable, which also enhances its value as a learning tool. Here, we describe the basic design and demonstrate imaging performance for a range of easily sourced specimens.
Collapse
Affiliation(s)
- Matthew Wincott
- Department of Engineering Science, University of Oxford, Oxford, OX1 3PJ, UK
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Andrew Jefferson
- Dementia Research Institute, Cardiff University, Cardiff, CF24 4HQ, UK, UK
| | - Ian M. Dobbie
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
- Department of Biology, Johns Hopkins University, 3400 N Charles St, Baltimore, MD 21218, USA
| | - Martin J. Booth
- Department of Engineering Science, University of Oxford, Oxford, OX1 3PJ, UK
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Ilan Davis
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
- Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Richard M. Parton
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
- Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| |
Collapse
|
8
|
Yu Z, Li Y, Geng D, Wu P. A wide-field microscope utilizing two cellphones for health-care applications. JOURNAL OF BIOPHOTONICS 2022; 15:e202100200. [PMID: 34783187 DOI: 10.1002/jbio.202100200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 10/14/2021] [Accepted: 11/09/2021] [Indexed: 06/13/2023]
Abstract
In this report, we report a wide field-of-view (FOV) bright field (BF) microscope with compact and portable optical components, mechanically attached to the existing camera unit of the cellphone. A white screen displayed on a cellphone as the illumination source to pump the sample of interest uniformly for the purpose of the reduction in assembly complexity and alignment. It offers a large FOV of 4.36 × 3.27 mm without digital zoom and a spatial resolution of 1.5 μm. Furthermore, we also have demonstrated the potential application for diseases diagnosis and screening by imaging malaria-infected blood sample and iron deficiency anemia blood sample in resource-constrained settings where mobile phone infrastructure is already ubiquitous but microscope is notoriously scarce.
Collapse
Affiliation(s)
- Zhenfang Yu
- Analysis and Test Center of Sichuan Province, Chengdu, China
- Scientific Equipments Company of Sichuan Province, Chengdu, China
| | - Yunfei Li
- Analysis and Test Center of Sichuan Province, Chengdu, China
- Scientific Equipments Company of Sichuan Province, Chengdu, China
| | - Dongxian Geng
- Analysis and Test Center of Sichuan Province, Chengdu, China
- Scientific Equipments Company of Sichuan Province, Chengdu, China
| | - Pinghui Wu
- College of Physics & Information Engineering, Quanzhou Normal University, Quanzhou, China
| |
Collapse
|
9
|
Automated detection and staging of malaria parasites from cytological smears using convolutional neural networks. BIOLOGICAL IMAGING 2022; 1:e2. [PMID: 35036920 PMCID: PMC8724263 DOI: 10.1017/s2633903x21000015] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 06/24/2021] [Accepted: 07/14/2021] [Indexed: 12/14/2022]
Abstract
Microscopic examination of blood smears remains the gold standard for laboratory inspection and diagnosis of malaria. Smear inspection is, however, time-consuming and dependent on trained microscopists with results varying in accuracy. We sought to develop an automated image analysis method to improve accuracy and standardization of smear inspection that retains capacity for expert confirmation and image archiving. Here, we present a machine learning method that achieves red blood cell (RBC) detection, differentiation between infected/uninfected cells, and parasite life stage categorization from unprocessed, heterogeneous smear images. Based on a pretrained Faster Region-Based Convolutional Neural Networks (R-CNN) model for RBC detection, our model performs accurately, with an average precision of 0.99 at an intersection-over-union threshold of 0.5. Application of a residual neural network-50 model to infected cells also performs accurately, with an area under the receiver operating characteristic curve of 0.98. Finally, combining our method with a regression model successfully recapitulates intraerythrocytic developmental cycle with accurate lifecycle stage categorization. Combined with a mobile-friendly web-based interface, called PlasmoCount, our method permits rapid navigation through and review of results for quality assurance. By standardizing assessment of Giemsa smears, our method markedly improves inspection reproducibility and presents a realistic route to both routine lab and future field-based automated malaria diagnosis.
Collapse
|
10
|
Tadrous PJ. PUMA - An open-source 3D-printed direct vision microscope with augmented reality and spatial light modulator functions. J Microsc 2021; 283:259-280. [PMID: 34151425 DOI: 10.1111/jmi.13043] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/22/2021] [Accepted: 06/17/2021] [Indexed: 11/28/2022]
Abstract
3D-printed microscopes are a topical emerging field in the literature. However most microscopes presented to date are quite novel re-imaginings of the microscope's mechanical design and they are either solely dependent on, or primarily geared towards, camera-based observations rather than ergonomic direct vision screening through an ocular lens. The reliance on camera, computer and monitor for observation introduces a compromise between portability, cost and the quality of an instant wide field of view. In this report, I introduce the Portable Upgradeable Modular and Affordable (PUMA) microscope which is an open-source 3D-printed multimodality microscope that employs a traditional upright design for ease of human direct visual observations and slide screening. PUMA uses standard RMS or C-mount objectives, with a tube length 160 mm, 170 mm or infinity and wide field high eye point ocular lenses. PUMA can use simple mirror-based illumination or can be configured to a full Köhler system with Abbe condenser for high numerical aperture observations including oil immersion. PUMA also has advanced digital/optical imaging features such as a digital spatial light modulator and - unique to any 3D printed microscope to date - an augmented reality heads-up display for interactive calibrated measurements. Digital camera imaging can also be used with PUMA - in fact PUMA can take up to three separate digital cameras simultaneously. PUMA can also function as a direct vision multi-header microscope for teaching or discussion. The illumination system is also modular and includes transillumination, epi-illumination, fluorescence, polarisation, dark ground and also Schlieren-based phase contrast and other Fourier optics filtering modalities. All these advanced features are available through an on-board, battery operated, microprocessor so no mains supply, smartphone, network connection, PC or external monitor are required making PUMA a truly portable system suitable for remote field work.
Collapse
Affiliation(s)
- Paul J Tadrous
- Department of Histopathology, TadPath Diagnostics, London, UK
| |
Collapse
|
11
|
Measurements of the swimming speeds of motile microorganisms using object tracking and their correlation with water pollution and rheology levels. Sci Rep 2021; 11:11821. [PMID: 34083631 PMCID: PMC8175393 DOI: 10.1038/s41598-021-91134-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 05/19/2021] [Indexed: 11/09/2022] Open
Abstract
Self-propelled microscopic organisms are ubiquitous in water. Such organisms' motility depends on hydrodynamic and physical factors related to the rheology of the surrounding media and biological factors depending on the organisms' state and well-being. Here we demonstrate that the swimming speed of Paramecium aurelia, a unicellular protozoan, globally found in fresh, brackish, and salt waters, can be used as a measurable frugal indicator of the presence of pollutants in water. This study establishes a significant and consistent relationship between Paramecia's swimming speed and the presence of five different organic and inorganic contaminants at varying concentrations centered around drinking water thresholds. The large size and ubiquity of the targeted microorganism, the avoidance of reagents or specialized tools for the measurement, and the simple data collection based on an object tracking algorithm enable the automatization of the assessment and real-time results using globally available technology.
Collapse
|
12
|
Gupta S, Mathews BJ, Ghantaa SN, Amerneni KC, Karuna T, Pakhare A, Joshi D, Khadanga S. Foldscope: Diagnostic Accuracy and Feasibility of its Use in National Malaria Control Program. J Microsc Ultrastruct 2021; 10:114-117. [PMID: 36504592 PMCID: PMC9728086 DOI: 10.4103/jmau.jmau_103_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 11/17/2020] [Indexed: 12/15/2022] Open
Abstract
Background Malaria has been an important public health all over the globe. Although conventional light microscopy is the gold standard of diagnosis, light microscopes are heavy, fragile, costly, and electricity dependent. Rapid diagnostic tests (RDTs) have become more popular but perform badly in temperate climate. This is because the RDT kits require maintenance of cold chain for its optimal use. In this regard, there is a recent interest in handheld malaria microscopy at the point of care in the field setting. Foldscopes are cheap, handy, nonfragile, and use mobile camera for illumination. The purpose of the study was to find whether foldscope can be used in the national vector borne disease control program (NVBDCP) in India. Methods Ten laboratory technicians were trained in identifying malaria parasites using foldscope and their mobiles. Later, they were provided with unassembled foldscope to document their test results for the preidentified malaria slides. The blood smears were stained as per the protocol of NVBDCP. The report of the index test (foldscope microscopy) was compared with the reference test (conventional microscopy). Results The sensitivity and specificity of the index test was found to be 13.3% (6.257-26.18), specificity of 97.78% (88.43-99.61), positive predictive value 85.71% (48.69-97.43), and negative predictive value 53.01% (42.38-63.38). The devise failure rate and test failure rate were 20% and 11.7%. The kappa agreement between the index and reference microscopy was only 11% and the McNemar P < 0.01. Conclusion The ×400 foldscope at its present magnification and illumination cannot be utilized in the field under NVBDCP.
Collapse
Affiliation(s)
- Sweta Gupta
- Department of Microbiology, AIIMS, Bhopal, Madhya Pradesh, India
| | | | | | | | - T. Karuna
- Department of Microbiology, AIIMS, Bhopal, Madhya Pradesh, India
| | | | - Deepti Joshi
- Department of Pathology, AIIMS, Bhopal, Madhya Pradesh, India
| | - Sagar Khadanga
- Department of Medicine, AIIMS, Bhopal, Madhya Pradesh, India,Address for correspondence: Dr. Sagar Khadanga, Department of Medicine, AIIMS, Saket Nagar, Bhopal, Madhya Pradesh, India. E-mail:
| |
Collapse
|
13
|
Wincott M, Jefferson A, Dobbie IM, Booth MJ, Davis I, Parton RM. Democratising "Microscopi": a 3D printed automated XYZT fluorescence imaging system for teaching, outreach and fieldwork. Wellcome Open Res 2021; 6:63. [PMID: 33977151 DOI: 10.12688/wellcomeopenres.16536.1] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/10/2021] [Indexed: 12/18/2022] Open
Abstract
Commercial fluorescence microscope stands and fully automated XYZt fluorescence imaging systems are generally beyond the limited budgets available for teaching and outreach. We have addressed this problem by developing "Microscopi", an accessible, affordable, DIY automated imaging system that is built from 3D printed and commodity off-the-shelf hardware, including electro-mechanical, computer and optical components. Our design features automated sample navigation and image capture with a simple web-based graphical user interface, accessible with a tablet or other mobile device. The light path can easily be switched between different imaging modalities. The open source Python-based control software allows the hardware to be driven as an integrated imaging system. Furthermore, the microscope is fully customisable, which also enhances its value as a learning tool. Here, we describe the basic design and demonstrate imaging performance for a range of easily sourced specimens.
Collapse
Affiliation(s)
- Matthew Wincott
- Department of Engineering Science, University of Oxford, Oxford, OX1 3PJ, UK.,Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Andrew Jefferson
- Dementia Research Institute, Cardiff University, Cardiff, CF24 4HQ, UK, UK
| | - Ian M Dobbie
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Martin J Booth
- Department of Engineering Science, University of Oxford, Oxford, OX1 3PJ, UK.,Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Ilan Davis
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK.,Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| | - Richard M Parton
- Micron Advanced Bio-imaging Unit, Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK.,Department of Biochemistry, University of Oxford, Oxford, OX1 3QU, UK
| |
Collapse
|
14
|
La Spina R, António DC, Bombera R, Lettieri T, Lequarré AS, Colpo P, Valsesia A. New Detection Platform for Screening Bacteria in Liquid Samples. BIOSENSORS 2021; 11:142. [PMID: 34062907 PMCID: PMC8147366 DOI: 10.3390/bios11050142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/21/2021] [Accepted: 04/28/2021] [Indexed: 11/26/2022]
Abstract
The development of sensitive methods for the determination of potential bacterial contamination is of upmost importance for environmental monitoring and food safety. In this study, we present a new method combining a fast pre-enrichment step using a microporous cryogel and a detection and identification step using antimicrobial peptides (AMPs) and labelled antibodies, respectively. The experimental method consists of: (i) the capture of large amounts of bacteria from liquid samples by using a highly porous and functionalized cryogel; (ii) the detection and categorisation of Gram-positive and Gram-negative bacteria by determining their affinities toward a small set of AMPs; and (iii) the identification of the bacterial strain by using labelled detection antibodies. As proof of concept, the assessment of the three steps of the analysis was performed by using Escherichia coli and Bacillus sp. as models for Gram-negative and Gram-positive bacteria, respectively. The use of AMPs with broad specificity combined with labelled antibodies enabled the detection and potential categorization of a large spectrum of unknown or unexpected bacteria.
Collapse
Affiliation(s)
- Rita La Spina
- European Commission, Joint Research Centre (JRC), Ispra, Italy; (R.L.S.); (D.C.A.); (R.B.); (T.L.); (P.C.)
| | - Diana C. António
- European Commission, Joint Research Centre (JRC), Ispra, Italy; (R.L.S.); (D.C.A.); (R.B.); (T.L.); (P.C.)
| | - Radoslaw Bombera
- European Commission, Joint Research Centre (JRC), Ispra, Italy; (R.L.S.); (D.C.A.); (R.B.); (T.L.); (P.C.)
| | - Teresa Lettieri
- European Commission, Joint Research Centre (JRC), Ispra, Italy; (R.L.S.); (D.C.A.); (R.B.); (T.L.); (P.C.)
| | | | - Pascal Colpo
- European Commission, Joint Research Centre (JRC), Ispra, Italy; (R.L.S.); (D.C.A.); (R.B.); (T.L.); (P.C.)
| | - Andrea Valsesia
- European Commission, Joint Research Centre (JRC), Ispra, Italy; (R.L.S.); (D.C.A.); (R.B.); (T.L.); (P.C.)
| |
Collapse
|
15
|
Hunt B, Ruiz AJ, Pogue BW. Smartphone-based imaging systems for medical applications: a critical review. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200421VR. [PMID: 33860648 PMCID: PMC8047775 DOI: 10.1117/1.jbo.26.4.040902] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Accepted: 03/29/2021] [Indexed: 05/15/2023]
Abstract
SIGNIFICANCE Smartphones come with an enormous array of functionality and are being more widely utilized with specialized attachments in a range of healthcare applications. A review of key developments and uses, with an assessment of strengths/limitations in various clinical workflows, was completed. AIM Our review studies how smartphone-based imaging (SBI) systems are designed and tested for specialized applications in medicine and healthcare. An evaluation of current research studies is used to provide guidelines for improving the impact of these research advances. APPROACH First, the established and emerging smartphone capabilities that can be leveraged for biomedical imaging are detailed. Then, methods and materials for fabrication of optical, mechanical, and electrical interface components are summarized. Recent systems were categorized into four groups based on their intended application and clinical workflow: ex vivo diagnostic, in vivo diagnostic, monitoring, and treatment guidance. Lastly, strengths and limitations of current SBI systems within these various applications are discussed. RESULTS The native smartphone capabilities for biomedical imaging applications include cameras, touchscreens, networking, computation, 3D sensing, audio, and motion, in addition to commercial wearable peripheral devices. Through user-centered design of custom hardware and software interfaces, these capabilities have the potential to enable portable, easy-to-use, point-of-care biomedical imaging systems. However, due to barriers in programming of custom software and on-board image analysis pipelines, many research prototypes fail to achieve a prospective clinical evaluation as intended. Effective clinical use cases appear to be those in which handheld, noninvasive image guidance is needed and accommodated by the clinical workflow. Handheld systems for in vivo, multispectral, and quantitative fluorescence imaging are a promising development for diagnostic and treatment guidance applications. CONCLUSIONS A holistic assessment of SBI systems must include interpretation of their value for intended clinical settings and how their implementations enable better workflow. A set of six guidelines are proposed to evaluate appropriateness of smartphone utilization in terms of clinical context, completeness, compactness, connectivity, cost, and claims. Ongoing work should prioritize realistic clinical assessments with quantitative and qualitative comparison to non-smartphone systems to clearly demonstrate the value of smartphone-based systems. Improved hardware design to accommodate the rapidly changing smartphone ecosystem, creation of open-source image acquisition and analysis pipelines, and adoption of robust calibration techniques to address phone-to-phone variability are three high priority areas to move SBI research forward.
Collapse
Affiliation(s)
- Brady Hunt
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Address all correspondence to Brady Hunt,
| | - Alberto J. Ruiz
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| |
Collapse
|
16
|
Looking Deeper: Using the Mobile Microscope to Support Young Children’s Scientific Inquiries. SUSTAINABILITY 2021. [DOI: 10.3390/su13073663] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This study adopted a quasi-experimental design with the support of qualitative information to investigate the impact of the mobile microscope on students’ science learning outcomes in a laboratory setting. The duration of the educational experiment was 5 weeks. Research participants comprised 56 third graders from two different classes at a public elementary school in Taiwan. Two classes with an equal number of students formed the experimental and control groups. Students in the experimental group employed mobile microscopes to support their scientific inquiries, whereas students in the control group used only tablet computers to facilitate their science learning. A standardized test was developed to measure students’ basic understanding of botany. Additionally, semi-structured concept mapping was employed as an alternative non-standardized test to evaluate students’ natural science learning. The quantitative findings indicated a significant instructional effect in the students’ concept mapping but not in the standardized test. The qualitative results revealed that mobile microscopes might motivate students to actively engage in knowledge discussion and sharing during plant observation.
Collapse
|
17
|
Liu Y, Rollins AM, Levenson RM, Fereidouni F, Jenkins MW. Pocket MUSE: an affordable, versatile and high-performance fluorescence microscope using a smartphone. Commun Biol 2021; 4:334. [PMID: 33712728 PMCID: PMC7955119 DOI: 10.1038/s42003-021-01860-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 02/02/2021] [Indexed: 12/11/2022] Open
Abstract
Smartphone microscopes can be useful tools for a broad range of imaging applications. This manuscript demonstrates the first practical implementation of Microscopy with Ultraviolet Surface Excitation (MUSE) in a compact smartphone microscope called Pocket MUSE, resulting in a remarkably effective design. Fabricated with parts from consumer electronics that are readily available at low cost, the small optical module attaches directly over the rear lens in a smartphone. It enables high-quality multichannel fluorescence microscopy with submicron resolution over a 10× equivalent field of view. In addition to the novel optical configuration, Pocket MUSE is compatible with a series of simple, portable, and user-friendly sample preparation strategies that can be directly implemented for various microscopy applications for point-of-care diagnostics, at-home health monitoring, plant biology, STEM education, environmental studies, etc.
Collapse
Affiliation(s)
- Yehe Liu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Andrew M Rollins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Richard M Levenson
- Department of Pathology and Laboratory Medicine, University of California Davis Medical Center, Sacramento, CA, USA
| | - Farzad Fereidouni
- Department of Pathology and Laboratory Medicine, University of California Davis Medical Center, Sacramento, CA, USA
| | - Michael W Jenkins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Department of Pediatrics, Case Western Reserve University, Cleveland, OH, USA.
| |
Collapse
|
18
|
Yang N, Peng J, Wu L, Han X, Shaheen N, Zou X. Hand-Held Zoom Micro-Imaging System Based on Microfluidic Chip for Point-of-Care Testing (POCT) of Vaginal Inflammation. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2021; 9:2800109. [PMID: 33552751 PMCID: PMC7861347 DOI: 10.1109/jtehm.2021.3054556] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 12/18/2020] [Accepted: 12/25/2020] [Indexed: 12/23/2022]
Abstract
BACKGROUND Vaginitis is a common and very private disease, and the current diagnosis is a frequent go to the hospital for testing. OBJECTIVE In order to improve the convenience and speed of detection, in this paper, we have developed a hand-held zoom micro-imaging system based on a microfluidic chip for point-of-care testing (POCT) of vaginal inflammation. METHODS This system consists of a microfluidic chip, an optical system and a hand-held zoom system assembled with a mobile phone. In terms of hardware, we designed a self-priming microfluidic chip, which can realize automatic sampling and full mixing of samples. We have also developed an optical system that can be adapted to smartphones, which has a lens group with a 37x magnification function and equipped with a zoom system with a focus range of 4mm to 6mm. In terms of software, we proposed an APP that can accurately identify cocci and can determine the inflammation level. RESULTS Compared with the recognition rate of the observers in the hospital, the detection accuracy of the portable recognition system is 95%, and after testing the clinical samples, the results were completely consistent with the hospital diagnosis results. The detection limit was 500 CFU / ml, which the relative error was (0.9 ± 0.3) %, and recognition time is 7 seconds. CONCLUSION This system is definitely suitable for women's point-of-care testing (POCT).
Collapse
Affiliation(s)
- Ning Yang
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Jingxin Peng
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Liang Wu
- Department of MedicineJiangsu UniversityZhenjiang212013China
| | - Xue Han
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Naila Shaheen
- Department of Electrical and Information EngineeringJiangsu UniversityZhenjiang212013China
| | - Xiaobo Zou
- Department of Food and Biological EngineeringJiangsu UniversityZhenjiang212013China
| |
Collapse
|
19
|
Hutchinson MR. Science convergence applied to psychoneuroimmunology: The future of measurement and imaging. Brain Behav Immun 2020; 88:262-269. [PMID: 32289367 DOI: 10.1016/j.bbi.2020.04.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 03/06/2020] [Accepted: 04/10/2020] [Indexed: 11/29/2022] Open
Abstract
The future of psychoneuroimmunology requires breakthrough technology discoveries. These next generation technologies need to address the unique challenges that are raised by imaging and measuring the activity of the neuroimmune interface in health and disease. The complexity of this challenge is centred around the multidimensionality of the neuroimmune system. These include novel challenges of capturing potent and rare biological signals over long times and vast anatomical distances. Here is a summary of the outcomes of the investments made by the Australian Research Council Centre of Excellence for Nanoscale BioPhotonics which was presented as part of the PNIRSAsia-Pacific symposium at the 2019 International Brain Research Organization.
Collapse
Affiliation(s)
- Mark R Hutchinson
- Adelaide Medical School, Faculty of Health Sciences, University of Adelaide, Adelaide, South Australia 5005, Australia; Australian Research Council Centre of Excellence for Nanoscale BioPhotonics, Adelaide, South Australia 5005, Australia; Institute for Photonics and Advanced Sensing, University of Adelaide, Adelaide, South Australia 5005, Australia; Robinson Research Institute, University of Adelaide, Adelaide, South Australia 5005, Australia
| |
Collapse
|
20
|
Rei Yan SL, Wakasuqui F, Wrenger C. Point-of-care tests for malaria: speeding up the diagnostics at the bedside and challenges in malaria cases detection. Diagn Microbiol Infect Dis 2020; 98:115122. [PMID: 32711185 DOI: 10.1016/j.diagmicrobio.2020.115122] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/21/2020] [Accepted: 06/25/2020] [Indexed: 12/18/2022]
Abstract
Malaria remains as one of the major public health problems worldwide. About 228 million cases occurred in 2018 only, with Africa bearing about 93% of the cases. Asymptomatic population carrying the various forms of the parasite Plasmodium in endemic areas plays an important role in the spread of the disease. To tackle this battle, more sensitive and precise detection kits for malaria are crucial to better control the number of new malaria cases. In this review, we not only discuss some of the available approaches to rapidly detect new malaria cases in endemic areas but also shed light on parallel problems that may affect the detection of individuals infected with the parasite, covering kelch 13 mutation, glucose 6-phosphate dehydrogenase deficiency, and hemoglobin disorders. Available approaches for malaria detection covered in this review are focused on point-of-care tests, including portable polymerase chain reaction and aptamers.
Collapse
Affiliation(s)
- Sun L Rei Yan
- Department of Parasitology, Institute of Biomedical Sciences at the University of São Paulo, São Paulo, Brazil
| | - Felipe Wakasuqui
- Department of Parasitology, Institute of Biomedical Sciences at the University of São Paulo, São Paulo, Brazil
| | - Carsten Wrenger
- Department of Parasitology, Institute of Biomedical Sciences at the University of São Paulo, São Paulo, Brazil.
| |
Collapse
|
21
|
Cesaretti M, Gal J, Bouveyron C, Diaspro A, Fontas E, Antonini A, Anty R, Iannelli A, Patouraux S. Accurate assessment of nonalcoholic fatty liver disease lesions in liver allograft biopsies by a smartphone platform: A proof of concept. Microsc Res Tech 2020; 83:1025-1031. [PMID: 32608555 DOI: 10.1002/jemt.23478] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 02/22/2020] [Accepted: 03/03/2020] [Indexed: 12/16/2022]
Abstract
Macrovesicular steatosis (MS) is a major risk factor for liver graft failure after transplantation and pathological microscopic examination of a frozen tissue section remains the gold standard for its assessment. However, the latter requires an experienced in-house pathologist for correct and rapid diagnosis as well as specific equipment that is not always available. Smartphones, which are must-have tools for everyone, are very suitable for incorporation into promising technology to generate moveable diagnostic tools as for telepathology. The study aims to compare the microscopic assessment of nonalcoholic fatty liver disease (NAFLD) spectrum in liver allograft biopsies by a smartphone microscopy platform (DIPLE device) to standard light microscopy. Forty-two liver graft biopsies were evaluated in transmitted light, using an iPhone X and the microscopy platform. A significant correlation was reported between the two different approaches for graft MS assessment (Spearman's correlation coefficient: r = .93; p < .001) and for steatohepatitis feature (r = .56; p < .001; r = .45; p < .001). Based on these findings, a smartphone integrated with a cheap microscopy platform can achieve adequate accuracy in the assessment of NAFLD in liver graft and could be used as an alternative to standard light microscopy when the latter is unavailable.
Collapse
Affiliation(s)
- Manuela Cesaretti
- Centre Hospitalier Universitaire de Nice - Digestive Surgery and Liver Transplantation Unit, Archet Hospital, Nice, France.,Istituto Italiano di Tecnologia, Genoa, Italy
| | - Jocelyn Gal
- Department of Epidemiology and Biostatistics, Centre Antoine Lacassagne, Nice, France
| | - Charles Bouveyron
- Laboratoire Jean-Alexandre Dieudonné, UMR 7351, Université Nice-Sophia-Antipolis, Nice, France
| | | | - Eric Fontas
- Department of Epidemiology and Biostatistics, Centre Antoine Lacassagne, Nice, France.,Laboratoire Jean-Alexandre Dieudonné, UMR 7351, Université Nice-Sophia-Antipolis, Nice, France
| | - Andrea Antonini
- Istituto Italiano di Tecnologia, Genoa, Italy.,SmartMicroOptics Srl, Genoa, Italy
| | - Rodolphe Anty
- Centre Hospitalier Universitaire de Nice - Digestive Surgery and Liver Transplantation Unit, Archet Hospital, Nice, France.,Université Côte d'Azur, Nice, France.,Inserm, U1065, Team 8 "Hepatic Complications of Obesity and Alcohol", Nice, France
| | - Antonio Iannelli
- Centre Hospitalier Universitaire de Nice - Digestive Surgery and Liver Transplantation Unit, Archet Hospital, Nice, France.,Université Côte d'Azur, Nice, France.,Inserm, U1065, Team 8 "Hepatic Complications of Obesity and Alcohol", Nice, France
| | | |
Collapse
|
22
|
A Cost-Effective In Situ Zooplankton Monitoring System Based on Novel Illumination Optimization. SENSORS 2020; 20:s20123471. [PMID: 32575543 PMCID: PMC7348824 DOI: 10.3390/s20123471] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/04/2020] [Accepted: 06/16/2020] [Indexed: 11/17/2022]
Abstract
A cost-effective and low-power-consumption underwater microscopic imaging system was developed to capture high-resolution zooplankton images in real-time. In this work, dark-field imaging was adopted to reduce backscattering and background noise. To produce an accurate illumination, a novel illumination optimization scheme for the light-emitting diode (LED) array was proposed and applied to design a lighting system for the underwater optical imaging of zooplankton. A multiple objective genetic algorithm was utilized to find the best location of the LED array, which resulted in the specific illumination level and most homogeneous irradiance in the target area. The zooplankton imaging system developed with the optimal configuration of LEDs was tested with Daphnia magna under laboratory conditions. The maximal field of view was 16 mm × 13 mm and the optical resolution was 15 μm. The experimental results showed that the imaging system developed could capture high-resolution and high-definition images of Daphnia. Subsequently, Daphnia individuals were accurately segmented and their geometrical characters were measured by using a classical image processing algorithm. This work provides a cost-effective zooplankton measuring system based on an optimization illumination configuration of an LED array, which has a great potential for minimizing the investment and operating costs associated with long-term in situ monitoring of the physiological state and population conditions of zooplankton.
Collapse
|
23
|
Szydlowski NA, Jing H, Alqashmi M, Hu YS. Cell phone digital microscopy using an oil droplet. BIOMEDICAL OPTICS EXPRESS 2020; 11:2328-2338. [PMID: 32499926 PMCID: PMC7249838 DOI: 10.1364/boe.389345] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 03/19/2020] [Accepted: 03/26/2020] [Indexed: 05/11/2023]
Abstract
We introduce an accessible cell phone imaging method using small droplets of microscope immersion oil and consumer-grade oils. Oil droplets were more resistant to evaporation than water droplets, and they resolved cellular structures that were visible using a 20x/0.75 objective. We optically characterized the droplets using a cell phone screen and resolution target. We further obtained cellular resolution images of an onion epidermis and a zea stem cross-section sample. Our droplet-based method enables stable optical imaging for diagnostic and educational purposes without custom setups, specialized components, or manufacturing processes.
Collapse
Affiliation(s)
- Nicole Anna Szydlowski
- Department of Chemistry, University of Illinois at Chicago, 845 W Taylor St., Chicago, IL 60607, USA
- Currently with the College of Pharmacy, University of Illinois at Chicago, 833 S. Wood St., Chicago, IL 60612, USA
| | - Haoran Jing
- Department of Chemistry, University of Illinois at Chicago, 845 W Taylor St., Chicago, IL 60607, USA
| | - Mohamed Alqashmi
- Department of Chemistry, University of Illinois at Chicago, 845 W Taylor St., Chicago, IL 60607, USA
| | - Ying Samuel Hu
- Department of Chemistry, University of Illinois at Chicago, 845 W Taylor St., Chicago, IL 60607, USA
| |
Collapse
|
24
|
Arumugam S, Colburn DAM, Sia SK. Biosensors for Personal Mobile Health: A System Architecture Perspective. ADVANCED MATERIALS TECHNOLOGIES 2020; 5:1900720. [PMID: 33043127 PMCID: PMC7546526 DOI: 10.1002/admt.201900720] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Indexed: 05/29/2023]
Abstract
Advances in mobile biosensors, integrating developments in materials science and instrumentation, are fueling an expansion in health data being collected and analyzed in decentralized settings. For example, semiconductor-based sensors are enabling measurement of vital signs, and microfluidic-based sensors are enabling measurement of biochemical markers. As biosensors for mobile health are becoming increasingly paired with smart devices, it will become critical for researchers to design biosensors - with appropriate functionalities and specifications - to work seamlessly with accompanying connected hardware and software. This article describes recent research in biosensors, as well as current mobile health devices in use, as classified into four distinct system architectures that take into account the biosensing and data processing functions required in personal mobile health devices. We also discuss the path forward for integrating biosensors into smartphone-based mobile health devices.
Collapse
Affiliation(s)
- Siddarth Arumugam
- Department of Biomedical Engineering, Columbia University, 10027 New York, United States
| | - David A M Colburn
- Department of Biomedical Engineering, Columbia University, 10027 New York, United States
| | - Samuel K Sia
- Department of Biomedical Engineering, Columbia University, 10027 New York, United States
| |
Collapse
|
25
|
Abstract
This article reviews the use of the smartphone in exotic pet medicine. The mobile app is the most instinctive use of the smartphone; however, there are very limited software dedicated to the exotic pet specifically. With an adapter, the smartphone can be attached to a regular endoscope and acts as a small endoscopic unit. Additional devices, such as infrared thermography or ultrasound, can be connected to the smartphone through the micro-USB port. The medical use of the smartphone is still in its infancy in veterinary medicine but can bring several solutions to the exotic pet practitioner and improve point-of-care evaluation.
Collapse
|
26
|
Rabha D, Sarmah A, Nath P. Design of a 3D printed smartphone microscopic system with enhanced imaging ability for biomedical applications. J Microsc 2019; 276:13-20. [PMID: 31498428 DOI: 10.1111/jmi.12829] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 08/31/2019] [Accepted: 09/04/2019] [Indexed: 01/01/2023]
Abstract
Portable, low-cost smartphone platform microscopic systems have emerged as a potential tool for imaging of various micron and submicron scale particles in recent years (Ozcan; Pirnstill and Coté; Breslauer et al.; Zhu et al.). In most of the reported works, it involves either the use of sophisticated optical set-ups along with a high-end computational tool for postprocessing of the captured images, or it requires a high-end configured smartphone to obtain enhanced imaging of the sample. Present work reports the working of a low-cost, field-portable 520× optical microscope using a smartphone. The proposed smartphone microscopic system has been designed by attaching a 3D printed compact optical set-up to the rear camera of a regular smartphone. By using cloud-based services, an image processing algorithm has been developed which can be accessed anytime through a mobile broadband network. Using this facility, the quality of the captured images can be further enhanced, thus obviating the need for dedicated computational tools for postprocessing of the images. With the designed microscopic system, an optical resolution ∼2 µm has been obtained. Upon postprocessing, the resolution of the captured images can be improved further. It is envisioned that with properly designed optical set-up in 3D printer and by developing an image processing application in the cloud, it is possible to obtain a low-cost, user-friendly, field-portable optical microscope on a regular smartphone that performs at par with that of a laboratory-grade microscope. LAY DESCRIPTION: With the ever-improving features both in hardware and software part, smartphone becomes ubiquitous in the modern civilised society with approximately 8.1 billion cell phone users across the world, and ∼40% of them can be considered as smartphones. This technology is undoubtedly the leading technology of the 21st century. Very recently, various researchers across the globe have utilised different sensing components embedded in the smartphone to convert it into a field-portable low-cost and user-friendly tool which can be used for different sensing and imaging purposes. By using simple optical components such as lens, pinhole, diffuser etc. and the camera of the smartphone, various groups have converted the phone into a microscopic imaging system. Again, by removing the camera lenses of the phone, holography images of microscopic particles by directly casting its shadows on the CMOS sensor on the phone has been demonstrated. The holographic images have subsequently been processed using the dedicated computational tool, and the original photos of the samples can be obtained. All the reported smartphone-based microscopic systems either suffer from relatively low field-of-view (FOV), resolution or it needs a high computational platform. Present work, demonstrate an alternative approach by which a reasonably good resolution (<2 µm) along with high optical magnification (520×) and a large FOV (150 µm) has been obtained on a regular smartphone. For postprocessing of the captured images an image processing algorithm has been developed in the cloud and the same can be accessed by the smartphone application, obviating the need of dedicated computational tool and a high-end configured smartphone for the proposed microscope. For the development of the proposed microscopic system, a simple optical set-up has been fabricated in a 3D printer. The set-up houses all the required optical components and the sample specimen with the 3D-printed XY stage, and it can be attached easily to the rear camera of the smartphone. Using the proposed microscopic system, enhanced imaging of USAF target and red blood cells have been successfully demonstrated. With the readily available optical components and a regular smartphone, the net cost involvement is significantly low (less than $250, including the smartphone). We envisioned that the designed system could be utilised for point-of-care diagnosis in resource-poor settings where access to the laboratory facilities is very limited.
Collapse
Affiliation(s)
- D Rabha
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Sonitpur, Assam, India
| | - A Sarmah
- Department of Pathology, Tezpur Medical College and Hospital, Sonitpur, Assam, India
| | - P Nath
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Sonitpur, Assam, India
| |
Collapse
|
27
|
Damodaran K, Crestani M, Jokhun DS, Shivashankar GV. Nuclear morphometrics and chromatin condensation patterns as disease biomarkers using a mobile microscope. PLoS One 2019; 14:e0218757. [PMID: 31314779 PMCID: PMC6636717 DOI: 10.1371/journal.pone.0218757] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 06/08/2019] [Indexed: 12/26/2022] Open
Abstract
Current cancer diagnosis involves the use of nuclear morphology and chromatin condensation signatures for accurate advanced stage classification. While such diagnostic approaches rely on high resolution imaging of the cell nucleus using expensive microscopy systems, developing portable mobile microscopes to visualize nuclear and chromatin condensation patterns is desirable at clinical settings with limited infrastructure. In this study, we develop a portable fluorescent mobile microscope capable of acquiring high resolution images of the nucleus and chromatin. Using this we extracted nuclear morphometric and chromatin texture based features and were able to discriminate between normal and cancer cells with similar accuracy as wide-field fluorescence microscopy. We were also able to detect subtle changes in nuclear and chromatin features in cells subjected to compressive forces, cytoskeletal perturbations and cytokine stimulation, thereby highlighting the sensitivity of the portable microscope. Taken together, we present a versatile platform to exploit nuclear morphometrics and chromatin condensation features as physical biomarkers for point-of-care diagnostic solutions.
Collapse
Affiliation(s)
- Karthik Damodaran
- Mechanobiology Institute and Department of Biological Sciences, National University of Singapore, Singapore, Singapore
| | - Michele Crestani
- Mechanobiology Institute and Department of Biological Sciences, National University of Singapore, Singapore, Singapore
| | - Doorgesh Sharma Jokhun
- Mechanobiology Institute and Department of Biological Sciences, National University of Singapore, Singapore, Singapore
| | - G. V. Shivashankar
- Mechanobiology Institute and Department of Biological Sciences, National University of Singapore, Singapore, Singapore
- Institute of Molecular Oncology, Italian Foundation for Cancer Research, Milan, Italy
- * E-mail:
| |
Collapse
|
28
|
Chen KL, Ven TN, Crane MM, Chen DE, Feng YC, Suzuki N, Russell AE, de Moraes D, Kaeberlein M. An inexpensive microscopy system for microfluidic studies in budding yeast. TRANSLATIONAL MEDICINE OF AGING 2019; 3:52-56. [PMID: 31511839 PMCID: PMC6738973 DOI: 10.1016/j.tma.2019.05.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Recently, microfluidic technologies have been developed to allow higher throughput collection of yeast replicative lifespan data. Adoption of these devices has been limited, in part, due to the high cost of the motorized microscopy instrumentation from mainline manufacturers. Inspired by recent development of open source microscopy hardware and software, we developed minimal-cost hardware attachments to provide long-term focus stabilization for lower-cost microscopes and open source software to manage concurrent time-lapse image acquisition from multiple microscopes. We hope that these tools will help spur the wider adoption of microfluidic technologies for the study of aging in yeast.
Collapse
Affiliation(s)
- Kenneth L. Chen
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
- Department of Genome Sciences, School of Medicine, University of Washington, Seattle, WA, USA
- Medical Scientist Training Program, School of Medicine, University of Washington, Seattle, WA, USA
| | - Toby N. Ven
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Matthew M. Crane
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Dexter E. Chen
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Yen-Chi Feng
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Nozomi Suzuki
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Adam E. Russell
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Diogo de Moraes
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
| | - Matt Kaeberlein
- Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA
- Department of Genome Sciences, School of Medicine, University of Washington, Seattle, WA, USA
- Corresponding author. Department of Pathology, School of Medicine, University of Washington, Seattle, WA, USA. (M. Kaeberlein)
| |
Collapse
|
29
|
Bornhorst J, Nustede EJ, Fudickar S. Mass Surveilance of C. elegans-Smartphone-Based DIY Microscope and Machine-Learning-Based Approach for Worm Detection. SENSORS 2019; 19:s19061468. [PMID: 30917520 PMCID: PMC6471353 DOI: 10.3390/s19061468] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 03/17/2019] [Accepted: 03/20/2019] [Indexed: 11/16/2022]
Abstract
The nematode Caenorhabditis elegans (C. elegans) is often used as an alternative animal model due to several advantages such as morphological changes that can be seen directly under a microscope. Limitations of the model include the usage of expensive and cumbersome microscopes, and restrictions of the comprehensive use of C. elegans for toxicological trials. With the general applicability of the detection of C. elegans from microscope images via machine learning, as well as of smartphone-based microscopes, this article investigates the suitability of smartphone-based microscopy to detect C. elegans in a complete Petri dish. Thereby, the article introduces a smartphone-based microscope (including optics, lighting, and housing) for monitoring C. elegans and the corresponding classification via a trained Histogram of Oriented Gradients (HOG) feature-based Support Vector Machine for the automatic detection of C. elegans. Evaluation showed classification sensitivity of 0.90 and specificity of 0.85, and thereby confirms the general practicability of the chosen approach.
Collapse
Affiliation(s)
- Julia Bornhorst
- Department of Food Chemistry, Institute of Nutritional Science, University of Potsdam, Arthur-Scheunert-Allee 114-116, 14558 Nuthetal, Germany.
- Food Chemistry, Faculty of Mathematics and Natural Sciences, University of Wuppertal, Gaußstraße 20, 42119 Wuppertal, Germany.
| | - Eike Jannik Nustede
- Assistance Systems and Medical Device Technology, Department of Health Services Research, Faculty of Medicine and Health Sciences, Carl von Ossietzky University Oldenburg, Ammerlaender Heerstr. 114-118, 26129 Oldenburg, Germany.
| | - Sebastian Fudickar
- Assistance Systems and Medical Device Technology, Department of Health Services Research, Faculty of Medicine and Health Sciences, Carl von Ossietzky University Oldenburg, Ammerlaender Heerstr. 114-118, 26129 Oldenburg, Germany.
| |
Collapse
|
30
|
Wiecha PR, Lecestre A, Mallet N, Larrieu G. Pushing the limits of optical information storage using deep learning. NATURE NANOTECHNOLOGY 2019; 14:237-244. [PMID: 30664755 DOI: 10.1038/s41565-018-0346-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Accepted: 12/10/2018] [Indexed: 05/10/2023]
Abstract
Diffraction drastically limits the bit density in optical data storage. To increase the storage density, alternative strategies involving supplementary recording dimensions and robust readout schemes must be explored. Here, we propose to encode multiple bits of information in the geometry of subwavelength dielectric nanostructures. A crucial problem in high-density information storage concepts is the robustness of the information readout with respect to fabrication errors and experimental noise. Using a machine-learning-based approach in which the scattering spectra are analysed by an artificial neural network, we achieve quasi-error-free readout of sequences of up to 9 bits, encoded in top-down fabricated silicon nanostructures. We demonstrate that probing few wavelengths instead of the entire spectrum is sufficient for robust information retrieval and that the readout can be further simplified, exploiting the RGB values from microscopy images. Our work paves the way towards high-density optical information storage using planar silicon nanostructures, compatible with mass-production-ready complementary metal-oxide-semiconductor technology.
Collapse
Affiliation(s)
| | | | - Nicolas Mallet
- LAAS, Université de Toulouse, CNRS, INP, Toulouse, France
| | | |
Collapse
|
31
|
Accurate 3D Shape, Displacement and Deformation Measurement Using a Smartphone. SENSORS 2019; 19:s19030719. [PMID: 30744213 PMCID: PMC6387444 DOI: 10.3390/s19030719] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 01/23/2019] [Accepted: 01/24/2019] [Indexed: 12/29/2022]
Abstract
The stereo-digital image correlation technique using two synchronized industrial-grade cameras has been extensively used for full-field 3D shape, displacement and deformation measurements. However, its use in resource-limited institutions and field settings is inhibited by the need for relatively expensive, bulky and complicated experimental set-ups. To mitigate this problem, we established a cost-effective and ultra-portable smartphone-based stereo-digital image correlation system, which only uses a smartphone and an optical attachment. This optical attachment is composed of four planar mirrors and a 3D-printed mirror support, and can split the incoming scene into two sub-images, simulating a stereovision system using two virtual smartphones. Although such a mirror-based system has already been used for stereo-image correlation, this is the first time it has been combined with a commercial smartphone. This publication explores the potential and limitations of such a configuration. We first verified the effectiveness and accuracy of this system in 3D shape and displacement measurement through shape measurement and in-plane and out-of-plane translation tests. Severe thermal-induced virtual strains (up to 15,000 με) were found in the measured results due to the smartphone heating. The mechanism for the generation of the temperature-dependent errors in this system was clearly and reasonably explained. After a simple preheating process, the smartphone-based system was demonstrated to be accurate in measuring the strain on the surface of a loaded composite specimen, with comparable accuracy to a strain gauge. Measurements of 3D deformation are illustrated by tracking the deformation on the surface of a deflating ball. This cost-effective and ultra-portable smartphone-based system not only greatly decreases the hardware investment in the system construction, but also increases convenience and efficiency of 3D deformation measurements, thus demonstrating a large potential in resource-limited and field settings.
Collapse
|
32
|
cellSTORM-Cost-effective super-resolution on a cellphone using dSTORM. PLoS One 2019; 14:e0209827. [PMID: 30625170 PMCID: PMC6326471 DOI: 10.1371/journal.pone.0209827] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 12/12/2018] [Indexed: 01/12/2023] Open
Abstract
High optical resolution in microscopy usually goes along with costly hardware components, such as lenses, mechanical setups and cameras. Several studies proved that Single Molecular Localization Microscopy can be made affordable, relying on off-the-shelf optical components and industry grade CMOS cameras. Recent technological advantages have yielded consumer-grade camera devices with surprisingly good performance. The camera sensors of smartphones have benefited of this development. Combined with computing power smartphones provide a fantastic opportunity for “imaging on a budget”. Here we show that a consumer cellphone is capable of optical super-resolution imaging by (direct) Stochastic Optical Reconstruction Microscopy (dSTORM), achieving optical resolution better than 80 nm. In addition to the use of standard reconstruction algorithms, we used a trained image-to-image generative adversarial network (GAN) to reconstruct video sequences under conditions where traditional algorithms provide sub-optimal localization performance directly on the smartphone. We believe that “cellSTORM” paves the way to make super-resolution microscopy not only affordable but available due to the ubiquity of cellphone cameras.
Collapse
|
33
|
Hernández-Neuta I, Neumann F, Brightmeyer J, Ba Tis T, Madaboosi N, Wei Q, Ozcan A, Nilsson M. Smartphone-based clinical diagnostics: towards democratization of evidence-based health care. J Intern Med 2019; 285:19-39. [PMID: 30079527 PMCID: PMC6334517 DOI: 10.1111/joim.12820] [Citation(s) in RCA: 95] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Recent advancements in bioanalytical techniques have led to the development of novel and robust diagnostic approaches that hold promise for providing optimal patient treatment, guiding prevention programs and widening the scope of personalized medicine. However, these advanced diagnostic techniques are still complex, expensive and limited to centralized healthcare facilities or research laboratories. This significantly hinders the use of evidence-based diagnostics for resource-limited settings and the primary care, thus creating a gap between healthcare providers and patients, leaving these populations without access to precision and quality medicine. Smartphone-based imaging and sensing platforms are emerging as promising alternatives for bridging this gap and decentralizing diagnostic tests offering practical features such as portability, cost-effectiveness and connectivity. Moreover, towards simplifying and automating bioanalytical techniques, biosensors and lab-on-a-chip technologies have become essential to interface and integrate these assays, bringing together the high precision and sensitivity of diagnostic techniques with the connectivity and computational power of smartphones. Here, we provide an overview of the emerging field of clinical smartphone diagnostics and its contributing technologies, as well as their wide range of areas of application, which span from haematology to digital pathology and rapid infectious disease diagnostics.
Collapse
Affiliation(s)
- I Hernández-Neuta
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, SE, Sweden
| | - F Neumann
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, SE, Sweden
| | - J Brightmeyer
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC, USA
| | - T Ba Tis
- Department of Materials Science and Engineering, North Carolina State University, Raleigh, NC, USA
| | - N Madaboosi
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, SE, Sweden
| | - Q Wei
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC, USA
| | - A Ozcan
- Electrical and Computer Engineering Department, University of California Los Angeles, Los Angeles, CA, USA
| | - M Nilsson
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, SE, Sweden
| |
Collapse
|
34
|
Ogasawara Y, Sugimoto R, Maruyama R, Arimoto H, Tamada Y, Watanabe W. Mobile-phone-based Rheinberg microscope with a light-emitting diode array. JOURNAL OF BIOMEDICAL OPTICS 2018; 24:1-6. [PMID: 30246509 PMCID: PMC6975239 DOI: 10.1117/1.jbo.24.3.031007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2018] [Accepted: 08/27/2018] [Indexed: 05/12/2023]
Abstract
Mobile phone technology has led to implementation of portable and inexpensive microscopes. Light-emitting diode (LED) array microscopes support various multicontrast imaging by flexible illumination patterns of the LED array that can be achieved without changing the optical components of the microscope. Here, we demonstrate a mobile-phone-based LED array microscope to realize multimodal imaging with bright-field, dark-field, differential phase-contrast, and Rheinberg illuminations using as few as 37 LED bulbs. Using this microscope, we obtained high-contrast images of living cells. Furthermore, by changing the color combinations of Rheinberg illumination, we were able to obtain images of living chromatic structures with enhanced or diminished contrast. This technique is expected to be a foundation for high-contrast microscopy used in modern field studies.
Collapse
Affiliation(s)
- Yuma Ogasawara
- Ritsumeikan University, College of Science and Engineering, Department of Electrical and Electronic Engineering, Kusatsu, Japan
| | - Ryo Sugimoto
- Ritsumeikan University, College of Science and Engineering, Department of Electrical and Electronic Engineering, Kusatsu, Japan
| | - Ryoji Maruyama
- Ritsumeikan University, College of Science and Engineering, Department of Electrical and Electronic Engineering, Kusatsu, Japan
| | - Hidenobu Arimoto
- National Institute of Advanced Industrial Science and Technology, Electronics and Photonics Research Institute, Tsukuba, Japan
| | - Yosuke Tamada
- National Institute for Basic Biology, Division of Evolutionary Biology, Okazaki, Japan
| | - Wataru Watanabe
- Ritsumeikan University, College of Science and Engineering, Department of Electrical and Electronic Engineering, Kusatsu, Japan
- Address all correspondence to: Wataru Watanabe, E-mail:
| |
Collapse
|