1
|
Shu G, Zhao L, Li F, Jiang Y, Zhang X, Yu C, Pan J, Sun SK. Metallic artifacts-free spectral computed tomography angiography based on renal clearable bismuth chelate. Biomaterials 2024; 305:122422. [PMID: 38128318 DOI: 10.1016/j.biomaterials.2023.122422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/28/2023] [Accepted: 12/07/2023] [Indexed: 12/23/2023]
Abstract
Computed tomography angiography (CTA) is one of the most important diagnosis techniques for various vascular diseases in clinic. However, metallic artifacts caused by metal implants and calcified plaques in more and more patients severely hinder its wide applications. Herein, we propose an improved metallic artifacts-free spectral CTA technique based on renal clearable bismuth chelate (Bi-DTPA dimeglumine) for the first time. Bi-DTPA dimeglumine owns the merits of ultra-simple synthetic process, approximately 100% of yield, large-scale production capability, good biocompatibility, and favorable renal clearable ability. More importantly, Bi-DTPA dimeglumine shows superior contrast-enhanced effect in CTA compared with clinical iohexol at a wide range of X-ray energies especially in higher X-ray energy. In rabbits' model with metallic transplants, Bi-DTPA dimeglumine assisted-spectral CTA can not only effectively mitigate metallic artifacts by reducing beam hardening effect under high X-ray energy, but also enables accurate delineation of vascular structure. Our proposed strategy opens a revolutionary way to solve the bottleneck problem of metallic artifacts in CTA examinations.
Collapse
Affiliation(s)
- Gang Shu
- School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China; Department of Radiology, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China
| | - Lu Zhao
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Fengtan Li
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Yingjian Jiang
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Xuening Zhang
- Department of Radiology, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China
| | - Chunshui Yu
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Jinbin Pan
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China.
| | - Shao-Kai Sun
- School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China.
| |
Collapse
|
2
|
Cuau L, Akl P, Gautheron A, Houmeau A, Chaput F, Yaromina A, Dubois L, Lambin P, Karpati S, Parola S, Rezaeifar B, Langlois JB, Si-Mohamed SA, Montcel B, Douek P, Lerouge F. Surface modification effect on contrast agent efficiency for X-ray based spectral photon-counting scanner/luminescence imaging: from fundamental study to in vivo proof of concept. NANOSCALE 2024; 16:2931-2944. [PMID: 38230699 DOI: 10.1039/d3nr03710j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2024]
Abstract
X-Ray imaging techniques are among the most widely used modalities in medical imaging and their constant evolution has led to the emergence of new technologies. The new generation of computed tomography (CT) systems - spectral photonic counting CT (SPCCT) and X-ray luminescence optical imaging - are examples of such powerful techniques. With these new technologies the rising demand for new contrast agents has led to extensive research in the field of nanoparticles and the possibility to merge the modalities appears to be highly attractive. In this work, we propose the design of lanthanide-based nanocrystals as a multimodal contrast agent with the two aforementioned technologies, allowing SPCCT and optical imaging at the same time. We present a systematic study on the effect of the Tb3+ doping level and surface modification on the generation of contrast with SPCCT and the luminescence properties of GdF3:Tb3+ nanocrystals (NCs), comparing different surface grafting with organic ligands and coatings with silica to make these NCs bio-compatible. A comparison of the luminescence properties of these NCs with UV revealed that the best results were obtained for the Gd0.9Tb0.1F3 composition. This property was confirmed under X-ray excitation in microCT and with SPCCT. Moreover, we could demonstrate that the intensity of the luminescence and the excited state lifetime are strongly affected by the surface modification. Furthermore, whatever the chemical nature of the ligand, the contrast with SPCCT did not change. Finally, the successful proof of concept of multimodal imaging was performed in vivo with nude mice in the SPCCT taking advantage of the so-called color K-edge imaging method.
Collapse
Affiliation(s)
- Loic Cuau
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Claude Bernard Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Pia Akl
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69621, Lyon, France
- Department of Radiology, Hospices Civils de Lyon, 69500 Bron, France
| | - A Gautheron
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69621, Lyon, France
- Université Jean Monnet Saint-Etienne, CNRS, Institut d'Optique Graduate School, Laboratoire Hubert Curien UMR 5516, F-42023, Saint-Etienne, France
| | - Angèle Houmeau
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69621, Lyon, France
| | - Frédéric Chaput
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Claude Bernard Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Ala Yaromina
- Department of Precision Medicine, The M-Lab, GROW - School of Oncology, Maastricht University, Maastricht, 6200, MD, The Netherlands
| | - Ludwig Dubois
- Department of Precision Medicine, The M-Lab, GROW - School of Oncology, Maastricht University, Maastricht, 6200, MD, The Netherlands
| | - Philippe Lambin
- Department of Precision Medicine, The M-Lab, GROW - School of Oncology, Maastricht University, Maastricht, 6200, MD, The Netherlands
| | - Szilvia Karpati
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Claude Bernard Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Stephane Parola
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Claude Bernard Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - B Rezaeifar
- Department of Precision Medicine, The M-Lab, GROW - School of Oncology, Maastricht University, Maastricht, 6200, MD, The Netherlands
- Research group NuTeC, Centre for Environmental Sciences, Hasselt University, Diepenbeek, Belgium
| | | | - Salim A Si-Mohamed
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69621, Lyon, France
- Department of Radiology, Hospices Civils de Lyon, 69500 Bron, France
| | - Bruno Montcel
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69621, Lyon, France
| | - Philippe Douek
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69621, Lyon, France
- Department of Radiology, Hospices Civils de Lyon, 69500 Bron, France
| | - Frederic Lerouge
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Claude Bernard Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| |
Collapse
|
3
|
Douek PC, Boccalini S, Oei EHG, Cormode DP, Pourmorteza A, Boussel L, Si-Mohamed SA, Budde RPJ. Clinical Applications of Photon-counting CT: A Review of Pioneer Studies and a Glimpse into the Future. Radiology 2023; 309:e222432. [PMID: 37787672 PMCID: PMC10623209 DOI: 10.1148/radiol.222432] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 03/24/2023] [Accepted: 04/11/2023] [Indexed: 10/04/2023]
Abstract
CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.
Collapse
Affiliation(s)
| | | | - Edwin H. G. Oei
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - David P. Cormode
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Amir Pourmorteza
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Loic Boussel
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Salim A. Si-Mohamed
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Ricardo P. J. Budde
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| |
Collapse
|
4
|
Boccalini S, Dessouky R, Rodesch PA, Lacombe H, Yagil Y, Lahoud E, Erhard K, Brendel B, Coulon P, Langlois JB, Chaput F, Parola S, Boussel L, Lerouge F, Si-Mohamed S, Douek PC. Gadolinium K-edge angiography with a spectral photon counting CT in atherosclerotic rabbits. Diagn Interv Imaging 2023; 104:490-499. [PMID: 37248095 DOI: 10.1016/j.diii.2023.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/29/2023] [Accepted: 05/05/2023] [Indexed: 05/31/2023]
Abstract
PURPOSE The purpose of this study was to investigate the feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) as obtained with spectral photon counting CT (SPCCT) in atherosclerotic rabbits. MATERIALS AND METHODS Seven atherosclerotic rabbits underwent angio-SPCCT acquisitions with two GBCAs, with similar intravenous injection protocol. Conventional and angio-Gd-K-edge images were reconstructed with the same parameters. Regions of interest were traced in different locations of the aorta and its branches. Hounsfield unit values, Gd concentrations, signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated and compared. The maximum diameter and the diameter of the aorta in regard to atherosclerotic plaques were measured by two observers. Images were subjectively evaluated regarding vessels' enhancement, artefacts, border sharpness and overall image quality. RESULTS In the analyzable six rabbits, Gd-K-edge allowed visualization of target vessels and no other structures. HU values and Gd concentrations were greatest in the largest artery (descending aorta, 5.6 ± 0.8 [SD] mm), and lowest in the smallest (renal arteries, 2.1 ± 0.3 mm). While greater for conventional images, CNR and SNR were satisfactory for both images (all P < 0.001). For one observer there were no statistically significant differences in either maximum or plaque-diameters (P = 0.45 and all P > 0.05 in post-hoc analysis, respectively). For the second observer, there were no significant differences for images reconstructed with the same parameters (all P < 0.05). All subjective criteria scored higher for conventional images compared to K-edge (all P < 0.01), with the highest scores for enhancement (4.3-4.4 vs. 3.1-3.4). CONCLUSION With SPCCT, angio-Gd-K-edge after injection of GBCAs in atherosclerotic rabbits is feasible and allows for angiography-like visualization of small arteries and for the reliable measurement of their diameters.
Collapse
Affiliation(s)
- Sara Boccalini
- Lyon University, Université Claude Bernard Lyon 1, 69100 Villeurbanne, France; Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France.
| | - Riham Dessouky
- Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France; Department of Radiology, Faculty of Medicine, Zagazig University, 44519, Zagazig, Egypt
| | - Pierre-Antoine Rodesch
- Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France
| | - Hugo Lacombe
- Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France
| | - Yoad Yagil
- Philips Medical Systems, 31004 Haifa, Israel
| | | | | | | | | | | | - Frederic Chaput
- Laboratoire de Chimie, Université de Lyon, École Normale Supérieure de Lyon, Université Claude Bernard Lyon 1, CNRS UMR 5182, 69364 Lyon, France
| | - Stephane Parola
- Laboratoire de Chimie, Université de Lyon, École Normale Supérieure de Lyon, Université Claude Bernard Lyon 1, CNRS UMR 5182, 69364 Lyon, France
| | - Loic Boussel
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France
| | - Frederic Lerouge
- Laboratoire de Chimie, Université de Lyon, École Normale Supérieure de Lyon, Université Claude Bernard Lyon 1, CNRS UMR 5182, 69364 Lyon, France
| | - Salim Si-Mohamed
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France
| | - Philippe C Douek
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France
| |
Collapse
|
5
|
Si-Mohamed SA, Boccalini S, Villien M, Yagil Y, Erhard K, Boussel L, Douek PC. First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype. Invest Radiol 2023; 58:459-471. [PMID: 36822663 PMCID: PMC10259214 DOI: 10.1097/rli.0000000000000965] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/20/2023] [Indexed: 02/25/2023]
Abstract
ABSTRACT Spectral photon-counting computed tomography (SPCCT) technology holds great promise for becoming the next generation of computed tomography (CT) systems. Its technical characteristics have many advantages over conventional CT imaging. For example, SPCCT provides better spatial resolution, greater dose efficiency for ultra-low-dose and low-dose protocols, and tissue contrast superior to that of conventional CT. In addition, SPCCT takes advantage of several known approaches in the field of spectral CT imaging, such as virtual monochromatic imaging and material decomposition imaging. In addition, SPCCT takes advantage of a new approach in this field, known as K-edge imaging, which allows specific and quantitative imaging of a heavy atom-based contrast agent. Hence, the high potential of SPCCT systems supports their ongoing investigation in clinical research settings. In this review, we propose an overview of our clinical research experience of a whole-body SPCCT clinical prototype, to give an insight into the potential benefits for clinical human imaging on image quality, diagnostic confidence, and new approaches in spectral CT imaging.
Collapse
Affiliation(s)
- Salim A. Si-Mohamed
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Sara Boccalini
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | | | | | | | - Loic Boussel
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Philippe C. Douek
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| |
Collapse
|
6
|
Lerouge F, Ong E, Rositi H, Mpambani F, Berner LP, Bolbos R, Olivier C, Peyrin F, Apputukan VK, Monnereau C, Andraud C, Chaput F, Berthezène Y, Braun B, Jucker M, Åslund AK, Nyström S, Hammarström P, R Nilsson KP, Lindgren M, Wiart M, Chauveau F, Parola S. In vivo targeting and multimodal imaging of cerebral amyloid-β aggregates using hybrid GdF 3 nanoparticles. Nanomedicine (Lond) 2023; 17:2173-2187. [PMID: 36927004 DOI: 10.2217/nnm-2022-0252] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023] Open
Abstract
Aim: To propose a new multimodal imaging agent targeting amyloid-β (Aβ) plaques in Alzheimer's disease. Materials & methods: A new generation of hybrid contrast agents, based on gadolinium fluoride nanoparticles grafted with a pentameric luminescent-conjugated polythiophene, was designed, extensively characterized and evaluated in animal models of Alzheimer's disease through MRI, two-photon microscopy and synchrotron x-ray phase-contrast imaging. Results & conclusion: Two different grafting densities of luminescent-conjugated polythiophene were achieved while preserving colloidal stability and fluorescent properties, and without affecting biodistribution. In vivo brain uptake was dependent on the blood-brain barrier status. Nevertheless, multimodal imaging showed successful Aβ targeting in both transgenic mice and Aβ fibril-injected rats.
Collapse
Affiliation(s)
- Frédéric Lerouge
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| | - Elodie Ong
- University of Lyon, Lyon Neuroscience Research Center, CNRS UMR, 5292, INSERM U1028, University of Lyon 1, Lyon, France
| | - Hugo Rositi
- University of Clermont Auvergne, Clermont Auvergne INP, Institut Pascal, CNRS UMR, 6602, Clermont-Ferrand, France
| | - Francis Mpambani
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| | - Lise-Prune Berner
- University of Lyon, CREATIS, INSA-Lyon, University of Lyon 1, CNRS UMR, 5220, INSERM U1206, Villeurbanne, France
| | | | - Cécile Olivier
- University of Lyon, CREATIS, INSA-Lyon, University of Lyon 1, CNRS UMR, 5220, INSERM U1206, Villeurbanne, France
| | - Françoise Peyrin
- University of Lyon, CREATIS, INSA-Lyon, University of Lyon 1, CNRS UMR, 5220, INSERM U1206, Villeurbanne, France
| | - Vinu K Apputukan
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| | - Cyrille Monnereau
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| | - Chantal Andraud
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| | - Frederic Chaput
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| | - Yves Berthezène
- University of Lyon, CREATIS, INSA-Lyon, University of Lyon 1, CNRS UMR, 5220, INSERM U1206, Villeurbanne, France
| | - Bettina Braun
- Department of Cellular Neurology, Hertie Institute for Clinical Brain Research, University Tübingen, Tübingen, Germany
| | - Mathias Jucker
- Department of Cellular Neurology, Hertie Institute for Clinical Brain Research, University Tübingen, Tübingen, Germany
| | - Andreas Ko Åslund
- Department of Physics, Chemistry, & Biology, Linköping University, Linköping, Sweden
| | - Sofie Nyström
- Department of Physics, Chemistry, & Biology, Linköping University, Linköping, Sweden
| | - Per Hammarström
- Department of Physics, Chemistry, & Biology, Linköping University, Linköping, Sweden
| | - K Peter R Nilsson
- Department of Physics, Chemistry, & Biology, Linköping University, Linköping, Sweden
| | - Mikael Lindgren
- Department of Physics, Norwegian University of Science & Technology, Trondheim, Norway
| | - Marlène Wiart
- University of Lyon, CarMeN laboratory, INSERM U1060, INRA, U1397, University of Lyon 1, INSA-Lyon, Oullins, France.,CNRS, Villeurbanne, France
| | - Fabien Chauveau
- University of Lyon, Lyon Neuroscience Research Center, CNRS UMR, 5292, INSERM U1028, University of Lyon 1, Lyon, France
| | - Stephane Parola
- University of Lyon, École Normale Supérieure de Lyon, Laboratoire de Chimie, University of Lyon 1, CNRS UMR, 5182, Lyon, France
| |
Collapse
|
7
|
Boccalini S, Si-Mohamed S. Spectral photon counting CT: Not just a pimped-up new version of dual-energy CT. Diagn Interv Imaging 2023; 104:51-52. [PMID: 36428159 DOI: 10.1016/j.diii.2022.10.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 10/18/2022] [Indexed: 11/23/2022]
Affiliation(s)
- Sara Boccalini
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Université Claude Bernard Lyon 1, 69100 Villeurbanne, France.
| | - Salim Si-Mohamed
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Université Lyon, INSA-Lyon, UJM-Saint Etienne, CREATIS, CNRS UMR 5220, Inserm U1206, 69100 Villeurbanne, France
| |
Collapse
|
8
|
Dong YC, Kumar A, Rosario-Berríos DN, Si-Mohamed S, Hsu JC, Nieves LM, Douek P, Noël PB, Cormode DP. Ytterbium Nanoparticle Contrast Agents for Conventional and Spectral Photon-Counting CT and Their Applications for Hydrogel Imaging. ACS APPLIED MATERIALS & INTERFACES 2022; 14:39274-39284. [PMID: 35975982 PMCID: PMC9513702 DOI: 10.1021/acsami.2c12354] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Significant work has been done to develop nanoparticle contrast agents for computed tomography (CT), with a focus on identifying safer and more effective formulations. Contrast agents for spectral photon-counting computed tomography (SPCCT), a fast-growing imaging modality derived from conventional CT, have also recently gained considerable attention. In this study, we explored the synthesis of ultrasmall ytterbium nanoparticles (YbNP) and demonstrated that, potentially, they can be used as conventional CT and SPCCT contrast agents. These nanoparticles were tested in vitro for their cytotoxicity and contrast-generating properties with a variety of imaging systems. When scanned with conventional CT and SPCCT at clinically relevant energies, YbNP are significantly more attenuating than gold nanoparticles (AuNP), the contrast agents that have been most well studied. Furthermore, YbNP were studied for their potential application for labeling and monitoring hydrogels. The presence of the YbNP payload in hydrogels allowed for hydrogel localization and tracking in vivo. Additionally, the in vivo imaging results revealed that YbNP generate higher contrast when compared to AuNP used as a label. In summary, this is the first research study to examine ultrasmall YbNP as conventional CT and SPCCT contrast agents, as well as using them in a hydrogel system to make it radiopaque. These findings underscore YbNP's utility as CT and SPCCT contrast agents, as well as their potential for tracking hydrogels in vivo.
Collapse
Affiliation(s)
- Yuxi C Dong
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Ananyaa Kumar
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Derick N Rosario-Berríos
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Biochemistry and Molecular Biophysics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Salim Si-Mohamed
- CREATIS, CNRS UMR 5220, INSERM U1206, INSA, University Claude Bernard Lyon 1, F69621 Lyon, France
| | - Jessica C Hsu
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Lenitza M Nieves
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Biochemistry and Molecular Biophysics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Philippe Douek
- CREATIS, CNRS UMR 5220, INSERM U1206, INSA, University Claude Bernard Lyon 1, F69621 Lyon, France
| | - Peter B Noël
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - David P Cormode
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
9
|
Polozhentsev OE, Pankin IA, Khodakova DV, Medvedev PV, Goncharova AS, Maksimov AY, Kit OI, Soldatov AV. Synthesis, Characterization and Biodistribution of GdF 3:Tb 3+@RB Nanocomposites. MATERIALS 2022; 15:ma15020569. [PMID: 35057287 PMCID: PMC8779613 DOI: 10.3390/ma15020569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 12/28/2021] [Accepted: 12/31/2021] [Indexed: 01/04/2023]
Abstract
Herein we report the development of a nanocomposite for X-ray-induced photodynamic therapy (X-PDT) and computed tomography (CT) based on PEG-capped GdF3:Tb3+ scintillating nanoparticles conjugated with Rose Bengal photosensitizer via electrostatic interactions. Scintillating GdF3:Tb3+ nanoparticles were synthesized by a facile and cost-effective wet chemical precipitation method. All synthesized nanoparticles had an elongated "spindle-like" clustered morphology with an orthorhombic structure. The structure, particle size, and morphology were determined by transmission electron microscopy (TEM), X-ray diffraction (XRD), and dynamic light scattering (DLS) analysis. The presence of a polyethylene glycol (PEG) coating and Rose Bengal conjugates was proved by Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TG), and ultraviolet-visible (UV-vis) analysis. Upon X-ray irradiation of the colloidal PEG-capped GdF3:Tb3+-Rose Bengal nanocomposite solution, an efficient fluorescent resonant energy transfer between scintillating nanoparticles and Rose Bengal was detected. The biodistribution of the synthesized nanoparticles in mice after intravenous administration was studied by in vivo CT imaging.
Collapse
Affiliation(s)
- Oleg E. Polozhentsev
- The Smart Materials Research Institute, Southern Federal University, 344090 Rostov-on-Don, Russia; (I.A.P.); (P.V.M.); (A.V.S.)
- Correspondence:
| | - Ilia A. Pankin
- The Smart Materials Research Institute, Southern Federal University, 344090 Rostov-on-Don, Russia; (I.A.P.); (P.V.M.); (A.V.S.)
| | - Darya V. Khodakova
- National Medical Research Centre for Oncology of the Ministry of Health of Russia, 344037 Rostov-on-Don, Russia; (D.V.K.); (A.S.G.); (A.Y.M.); (O.I.K.)
| | - Pavel V. Medvedev
- The Smart Materials Research Institute, Southern Federal University, 344090 Rostov-on-Don, Russia; (I.A.P.); (P.V.M.); (A.V.S.)
| | - Anna S. Goncharova
- National Medical Research Centre for Oncology of the Ministry of Health of Russia, 344037 Rostov-on-Don, Russia; (D.V.K.); (A.S.G.); (A.Y.M.); (O.I.K.)
| | - Aleksey Yu. Maksimov
- National Medical Research Centre for Oncology of the Ministry of Health of Russia, 344037 Rostov-on-Don, Russia; (D.V.K.); (A.S.G.); (A.Y.M.); (O.I.K.)
| | - Oleg I. Kit
- National Medical Research Centre for Oncology of the Ministry of Health of Russia, 344037 Rostov-on-Don, Russia; (D.V.K.); (A.S.G.); (A.Y.M.); (O.I.K.)
| | - Alexander V. Soldatov
- The Smart Materials Research Institute, Southern Federal University, 344090 Rostov-on-Don, Russia; (I.A.P.); (P.V.M.); (A.V.S.)
| |
Collapse
|
10
|
Spectral Photon-Counting CT Technology in Chest Imaging. J Clin Med 2021; 10:jcm10245757. [PMID: 34945053 PMCID: PMC8704215 DOI: 10.3390/jcm10245757] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/30/2021] [Accepted: 12/02/2021] [Indexed: 12/17/2022] Open
Abstract
The X-ray imaging field is currently undergoing a period of rapid technological innovation in diagnostic imaging equipment. An important recent development is the advent of new X-ray detectors, i.e., photon-counting detectors (PCD), which have been introduced in recent clinical prototype systems, called PCD computed tomography (PCD-CT) or photon-counting CT (PCCT) or spectral photon-counting CT (SPCCT) systems. PCD allows a pixel up to 200 microns pixels at iso-center, which is much smaller than that can be obtained with conventional energy integrating detectors (EID). PCDs have also a higher dose efficiency than EID mainly because of electronic noise suppression. In addition, the energy-resolving capabilities of these detectors allow generating spectral basis imaging, such as the mono-energetic images or the water/iodine material images as well as the K-edge imaging of a contrast agent based on atoms of high atomic number. In recent years, studies have therefore been conducted to determine the potential of PCD-CT as an alternative to conventional CT for chest imaging.
Collapse
|
11
|
Shapoval O, Sulimenko V, Klebanovych A, Rabyk M, Shapoval P, Kaman O, Rydvalová E, Filipová M, Dráberová E, Dráber P, Horák D. Multimodal fluorescently labeled polymer-coated GdF 3 nanoparticles inhibit degranulation in mast cells. NANOSCALE 2021; 13:19023-19037. [PMID: 34755752 DOI: 10.1039/d1nr06127e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Multimodal gadolinium fluoride nanoparticles belong to potential contrast agents useful for bimodal optical fluorescence and magnetic resonance imaging. However, the metallic nature of the nanoparticles, similarly to some paramagnetic iron oxides, might induce allergic and anaphylactic reactions in patients after administration. A reduction of these adverse side effects is a priority for the safe application of the nanoparticles. Herein, we prepared paramagnetic poly(4-styrenesulfonic acid-co-maleic acid) (PSSMA)-stabilized GdF3 nanoparticles with surface modified by Atto 488-labeled poly(styrene-grad-2-dimethylaminoethyl acrylate)-block-poly(2-dimethylaminoethyl acrylate) (PSDA-A488) with reactive amino groups for introduction of an additional imaging (luminescence) modality and possible targeting of anticancer drugs. The saturation magnetization of GdF3@PSSMA particles according to SQUID magnetometry reached 157 Am2 kg-1 at 2 K and magnetic field of 7 T. GdF3@PSSMA-PSDA-A488 nanoparticles were well tolerated by human cervical adenocarcinoma (HeLa), mouse bone marrow-derived mast cells (BMMC), and rat basophilic mast cells (RBL-2H3); the particles also affected cell morphology and protein tyrosine phosphorylation in mast cells. Moreover, the nanoparticles interfered with the activation of mast cells by multivalent antigens and inhibited calcium mobilization and cell degranulation. These findings show that the new multimodal GdF3-based nanoparticles possess properties useful for various imaging methods and might minimize mast cell degranulation incurred after future nanoparticle diagnostic administration.
Collapse
Affiliation(s)
- Oleksandr Shapoval
- Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| | - Vadym Sulimenko
- Laboratory of Biology of Cytoskeleton, Institute of Molecular Genetics of the Czech Academy of Sciences, Vídeňská 1083, 142 20 Prague 4, Czech Republic
| | - Anastasiya Klebanovych
- Laboratory of Biology of Cytoskeleton, Institute of Molecular Genetics of the Czech Academy of Sciences, Vídeňská 1083, 142 20 Prague 4, Czech Republic
| | - Mariia Rabyk
- Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| | - Pavlo Shapoval
- Department of Physical, Analytical and General Chemistry, Lviv Polytechnic National University, Sv. Yura Sq. 9, 79013 Lviv, Ukraine
| | - Ondřej Kaman
- Institute of Physics of the Czech Academy of Sciences, Cukrovarnická 112/10, 162 00 Prague 6, Czech Republic
| | - Eliška Rydvalová
- Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| | - Marcela Filipová
- Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| | - Eduarda Dráberová
- Laboratory of Biology of Cytoskeleton, Institute of Molecular Genetics of the Czech Academy of Sciences, Vídeňská 1083, 142 20 Prague 4, Czech Republic
| | - Pavel Dráber
- Laboratory of Biology of Cytoskeleton, Institute of Molecular Genetics of the Czech Academy of Sciences, Vídeňská 1083, 142 20 Prague 4, Czech Republic
| | - Daniel Horák
- Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského nám. 2, 162 06 Prague 6, Czech Republic
| |
Collapse
|
12
|
Hubert V, Hristovska I, Karpati S, Benkeder S, Dey A, Dumot C, Amaz C, Chounlamountri N, Watrin C, Comte J, Chauveau F, Brun E, Marche P, Lerouge F, Parola S, Berthezène Y, Vorup‐Jensen T, Pascual O, Wiart M. Multimodal Imaging with NanoGd Reveals Spatiotemporal Features of Neuroinflammation after Experimental Stroke. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2101433. [PMID: 34197055 PMCID: PMC8425862 DOI: 10.1002/advs.202101433] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/12/2021] [Indexed: 05/09/2023]
Abstract
The purpose of this study is to propose and validate a preclinical in vivo magnetic resonance imaging (MRI) tool to monitor neuroinflammation following ischemic stroke, based on injection of a novel multimodal nanoprobe, NanoGd, specifically designed for internalization by phagocytic cells. First, it is verified that NanoGd is efficiently internalized by microglia in vitro. In vivo MRI coupled with intravenous injection of NanoGd in a permanent middle cerebral artery occlusion mouse model results in hypointense signals in the ischemic lesion. In these mice, longitudinal two-photon intravital microscopy shows NanoGd internalization by activated CX3CR1-GFP/+ cells. Ex vivo analysis, including phase contrast imaging with synchrotron X-ray, histochemistry, and transmission electron microscopy corroborate NanoGd accumulation within the ischemic lesion and uptake by immune phagocytic cells. Taken together, these results confirm the potential of NanoGd-enhanced MRI as an imaging biomarker of neuroinflammation at the subacute stage of ischemic stroke. As far as it is known, this work is the first to decipher the working mechanism of MR signals induced by a nanoparticle passively targeted at phagocytic cells by performing intravital microscopy back-to-back with MRI. Furthermore, using a gadolinium-based rather than an iron-based contrast agent raises future perspectives for the development of molecular imaging with emerging computed tomography technologies.
Collapse
Affiliation(s)
- Violaine Hubert
- Univ‐LyonIRIS TeamCarMeN LaboratoryInserm U1060INRA U1397INSA LyonUniversité Claude Bernard Lyon 1Groupement Hospitalier Est59 bd. PinelBron69500France
| | - Ines Hristovska
- SYNATAC TeamInstitut NeuroMyoGèneUniversité Claude Bernard Lyon 1CNRS UMR 5310, INSERM U1217Faculté de Médecine et de Pharmacie8 avenue RockefellerLyon69008France
| | - Szilvia Karpati
- Université de LyonÉcole Normale Supérieure de LyonCNRS UMR 5182Université Claude Bernard Lyon 1Laboratoire de ChimieLyonF69342France
| | - Sarah Benkeder
- SYNATAC TeamInstitut NeuroMyoGèneUniversité Claude Bernard Lyon 1CNRS UMR 5310, INSERM U1217Faculté de Médecine et de Pharmacie8 avenue RockefellerLyon69008France
| | - Arindam Dey
- Institut pour l'Avancée des BiosciencesCentre de Recherche UGA / Inserm U 1209 / CNRS UMR 5309Site Santé ‐ Allée des AlpesLa Tronche38700France
| | - Chloé Dumot
- Univ‐LyonIRIS TeamCarMeN LaboratoryInserm U1060INRA U1397INSA LyonUniversité Claude Bernard Lyon 1Groupement Hospitalier Est59 bd. PinelBron69500France
| | - Camille Amaz
- Clinical Investigation CenterHospices Civils de LyonLouis Pradel Hospital28 avenue Doyen LépineBron69500France
| | - Naura Chounlamountri
- SYNATAC TeamInstitut NeuroMyoGèneUniversité Claude Bernard Lyon 1CNRS UMR 5310, INSERM U1217Faculté de Médecine et de Pharmacie8 avenue RockefellerLyon69008France
| | - Chantal Watrin
- SYNATAC TeamInstitut NeuroMyoGèneUniversité Claude Bernard Lyon 1CNRS UMR 5310, INSERM U1217Faculté de Médecine et de Pharmacie8 avenue RockefellerLyon69008France
| | - Jean‐Christophe Comte
- FORGETTING TeamLyon Neuroscience Research Center (CRNL)CNRS UMR5292INSERM U1028Université Claude Bernard Lyon 1Centre Hospitalier Le Vinatier ‐ Bâtiment 462 ‐ Neurocampus Michel Jouvet95 boulevard PinelBron69675France
| | - Fabien Chauveau
- Université de LyonLyon Neuroscience Research Center (CRNL)CNRS UMR5292INSERM U1028Université Claude Bernard Lyon 1Groupement Hospitalier Est ‐ CERMEP59 bd PinelBron Cedex69677France
| | - Emmanuel Brun
- Synchrotron Radiation for Biomedical Research (STROBE)UA7 INSERMUniversité Grenoble AlpesMedical Beamline at the European Synchrotron Radiation Facility71 Avenue des MartyrsGrenoble Cedex 938043France
| | - Patrice Marche
- Institut pour l'Avancée des BiosciencesCentre de Recherche UGA / Inserm U 1209 / CNRS UMR 5309Site Santé ‐ Allée des AlpesLa Tronche38700France
| | - Fréderic Lerouge
- Université de LyonÉcole Normale Supérieure de LyonCNRS UMR 5182Université Claude Bernard Lyon 1Laboratoire de ChimieLyonF69342France
| | - Stéphane Parola
- Université de LyonÉcole Normale Supérieure de LyonCNRS UMR 5182Université Claude Bernard Lyon 1Laboratoire de ChimieLyonF69342France
| | - Yves Berthezène
- Univ‐LyonCreatis LaboratoryCNRS UMR5220Inserm U1044INSA LyonVilleurbanne Cedex69621France
| | - Thomas Vorup‐Jensen
- Department of BiomedicineBiophysical Immunology LaboratoryAarhus UniversityAarhus CDK‐8000Denmark
| | - Olivier Pascual
- SYNATAC TeamInstitut NeuroMyoGèneUniversité Claude Bernard Lyon 1CNRS UMR 5310, INSERM U1217Faculté de Médecine et de Pharmacie8 avenue RockefellerLyon69008France
| | - Marlène Wiart
- Univ‐LyonIRIS TeamCarMeN LaboratoryInserm U1060INRA U1397INSA LyonUniversité Claude Bernard Lyon 1Groupement Hospitalier Est59 bd. PinelBron69500France
| |
Collapse
|
13
|
van der Werf NR, Si-Mohamed S, Rodesch PA, van Hamersvelt RW, Greuter MJW, Boccalini S, Greffier J, Leiner T, Boussel L, Willemink MJ, Douek P. Coronary calcium scoring potential of large field-of-view spectral photon-counting CT: a phantom study. Eur Radiol 2021; 32:152-162. [PMID: 34255159 PMCID: PMC8660747 DOI: 10.1007/s00330-021-08152-w] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/05/2021] [Accepted: 06/14/2021] [Indexed: 12/22/2022]
Abstract
OBJECTIVE The aim of the current study was, first, to assess the coronary artery calcium (CAC) scoring potential of spectral photon-counting CT (SPCCT) in comparison with computed tomography (CT) for routine clinical protocols. Second, improved CAC detection and quantification at reduced slice thickness were assessed. METHODS Raw data was acquired and reconstructed with several combinations of reduced slice thickness and increasing strengths of iterative reconstruction (IR) for both CT systems with routine clinical CAC protocols for CT. Two CAC-containing cylindrical inserts, consisting of CAC of different densities and sizes, were placed in an anthropomorphic phantom. A specific CAC was detectable when 3 or more connected voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). For all reconstructions, total CAC detectability was compared between both CT systems. Significant differences in CAC quantification (Agatston and volume scores) were assessed with Mann-Whitney U tests. Furthermore, volume scores were compared with the known CAC physical. RESULTS CAC scores for routine clinical protocols were comparable between SPCCT and CT. SPCCT showed 34% and 4% higher detectability of CAC for the small and large phantom, respectively. At reduced slice thickness, CAC detection increased by 142% and 169% for CT and SPCCT, respectively. In comparison with CT, volume scores from SPCCT were more comparable with the physical volume of the CAC. CONCLUSION CAC scores using routine clinical protocols are comparable between conventional CT and SPCCT. The increased spatial resolution of SPCCT allows for increased detectability and more accurate CAC volume estimation. KEY POINTS • Coronary artery calcium scores using routine clinical protocols are comparable between conventional CT and spectral photon-counting CT. • In comparison with conventional CT, increased coronary artery calcium detectability was shown for spectral photon-counting CT due to increased spatial resolution. • Volumes scores were more accurately determined with spectral photon-counting CT.
Collapse
Affiliation(s)
- Niels R van der Werf
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands. .,Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
| | - S Si-Mohamed
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - P A Rodesch
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - R W van Hamersvelt
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - M J W Greuter
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - S Boccalini
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - J Greffier
- Department of medical imaging, Medical Imaging Group, Univ Montpellier, CHU Nimes, 2415, Nimes, EA, France
| | - T Leiner
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - L Boussel
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - M J Willemink
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - P Douek
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
14
|
Si-Mohamed SA, Sigovan M, Hsu JC, Tatard-Leitman V, Chalabreysse L, Naha PC, Garrivier T, Dessouky R, Carnaru M, Boussel L, Cormode DP, Douek PC. In Vivo Molecular K-Edge Imaging of Atherosclerotic Plaque Using Photon-counting CT. Radiology 2021; 300:98-107. [PMID: 33944628 PMCID: PMC8217298 DOI: 10.1148/radiol.2021203968] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.
Collapse
Affiliation(s)
- Salim A Si-Mohamed
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Monica Sigovan
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Jessica C Hsu
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Valérie Tatard-Leitman
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Lara Chalabreysse
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Pratap C Naha
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Thibaut Garrivier
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Riham Dessouky
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Miruna Carnaru
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Loic Boussel
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - David P Cormode
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Philippe C Douek
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| |
Collapse
|
15
|
A New Outlook on the Ability to Accumulate an Iodine Contrast Agent in Solid Lung Tumors Based on Virtual Monochromatic Images in Dual Energy Computed Tomography (DECT): Analysis in Two Phases of Contrast Enhancement. J Clin Med 2021; 10:jcm10091870. [PMID: 33925945 PMCID: PMC8123482 DOI: 10.3390/jcm10091870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/16/2021] [Accepted: 04/19/2021] [Indexed: 11/25/2022] Open
Abstract
For some time, dual energy computed tomography (DECT) has been an established method used in a vast array of clinical applications, including lung nodule assessment. The aim of this study was to analyze (using monochromatic DECT images) how the X-ray absorption of solitary pulmonary nodules (SPNs) depends on the iodine contrast agent and when X-ray absorption is no longer dependent on the accumulated contrast agent. Sixty-six patients with diagnosed solid lung tumors underwent DECT scans in the late arterial phase (AP) and venous phase (VP) between January 2017 and June 2018. Statistically significant correlations (p ≤ 0.001) of the iodine contrast concentration were found in the energy range of 40–90 keV in the AP phase and in the range of 40–80 keV in the VP phase. The strongest correlation was found between the concentrations of the contrast agent and the scanning energy of 40 keV. At the higher scanning energy, no significant correlations were found. We concluded that it is most useful to evaluate lung lesions in DECT virtual monochromatic images (VMIs) in the energy range of 40–80 keV. We recommend assessing SPNs in only one phase of contrast enhancement to reduce the absorbed radiation dose.
Collapse
|
16
|
Karpati S, Hubert V, Hristovska I, Lerouge F, Chaput F, Bretonnière Y, Andraud C, Banyasz A, Micouin G, Monteil M, Lecouvey M, Mercey-Ressejac M, Dey AK, Marche PN, Lindgren M, Pascual O, Wiart M, Parola S. Hybrid multimodal contrast agent for multiscale in vivo investigation of neuroinflammation. NANOSCALE 2021; 13:3767-3781. [PMID: 33555278 DOI: 10.1039/d0nr07026b] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Neuroinflammation is a process common to several brain pathologies. Despites its medical relevance, it still remains poorly understood; there is therefore a need to develop new in vivo preclinical imaging strategies to monitor inflammatory processes longitudinally. We here present the development of a hybrid imaging nanoprobe named NP3, that was specifically designed to get internalized by phagocytic cells and imaged in vivo with MRI and bi-photon microscopy. NP3 is composed of a 16 nm core of gadolinium fluoride (GdF3), coated with bisphosphonate polyethylene glycol (PEG) and functionalized with a Lemke-type fluorophore. It has a hydrodynamic diameter of 28 ± 8 nm and a zeta potential of -42 ± 6 mV. The MR relaxivity ratio at 7 T is r1/r2 = 20; therefore, NP3 is well suited as a T2/T2* contrast agent. In vitro cytotoxicity assessments performed on four human cell lines revealed no toxic effects of NP3. In addition, NP3 is internalized by macrophages in vitro without inducing inflammation or cytotoxicity. In vivo, uptake of NP3 has been observed in the spleen and the liver. NP3 has a prolonged vascular remanence, which is an advantage for macrophage uptake in vivo. The proof-of-concept that NP3 may be used as a contrast agent targeting phagocytic cells is provided in an animal model of ischemic stroke in transgenic CX3CR1-GFP/+ mice using three complementary imaging modalities: MRI, intravital two-photon microscopy and phase contrast imaging with synchrotron X-rays. In summary, NP3 is a promising preclinical tool for the multiscale and multimodal investigation of neuroinflammation.
Collapse
Affiliation(s)
- Szilvia Karpati
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Violaine Hubert
- Univ-Lyon, CarMeN laboratory, Inserm U1060, INRA U1397, INSA Lyon, Université Claude Bernard Lyon 1, F-69600, Oullins, France
| | - Inès Hristovska
- Institut NeuroMyoGène, Université Claude Bernard Lyon 1, CNRS UMR 5310, INSERM U1217, Université Lyon, Villeurbanne 69100, France
| | - Frédéric Lerouge
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Frédéric Chaput
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Yann Bretonnière
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Chantal Andraud
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Akos Banyasz
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Guillaume Micouin
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| | - Maëlle Monteil
- Université Sorbonne Paris Nord, Laboratoire CSPBAT, CNRS UMR 7244, F-93017 Bobigny Cedex, France
| | - Marc Lecouvey
- Université Sorbonne Paris Nord, Laboratoire CSPBAT, CNRS UMR 7244, F-93017 Bobigny Cedex, France
| | - Marion Mercey-Ressejac
- Institute for Advanced Biosciences, Université Grenoble-Alpes, INSERM U1209, CNRS UMR5309, La Tronche, France
| | - Arindam K Dey
- Institute for Advanced Biosciences, Université Grenoble-Alpes, INSERM U1209, CNRS UMR5309, La Tronche, France
| | - Patrice N Marche
- Institute for Advanced Biosciences, Université Grenoble-Alpes, INSERM U1209, CNRS UMR5309, La Tronche, France
| | - Mikael Lindgren
- Norwegian University of Science and Technology - Department of Physics, Høgskoleringen 5, Realfagbygget, 7491 Trondheim, Norway
| | - Olivier Pascual
- Institut NeuroMyoGène, Université Claude Bernard Lyon 1, CNRS UMR 5310, INSERM U1217, Université Lyon, Villeurbanne 69100, France
| | - Marlène Wiart
- Univ-Lyon, CarMeN laboratory, Inserm U1060, INRA U1397, INSA Lyon, Université Claude Bernard Lyon 1, F-69600, Oullins, France
| | - Stephane Parola
- Université de Lyon, Ecole Normale Supérieure de Lyon, CNRS UMR 5182, Université Lyon 1, Laboratoire de Chimie, 46 allée d'Italie, F69364 Lyon, France.
| |
Collapse
|
17
|
Spectral photon-counting CT imaging of colorectal peritoneal metastases: initial experience in rats. Sci Rep 2020; 10:13394. [PMID: 32770125 PMCID: PMC7414131 DOI: 10.1038/s41598-020-70282-w] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 07/23/2020] [Indexed: 12/16/2022] Open
Abstract
Computed tomography imaging plays a major role in the preoperative assessment of tumor burden by providing an accurate mapping of the distribution of peritoneal metastases (PM). Spectral Photon Counting Computed Tomography (SPCCT) is an innovative imaging modality that could overcome the current limitations of conventional CT, offering not only better spatial resolution but also better contrast resolution by allowing the discrimination of multiple contrast agents. Based on this capability, we tested the feasibility of SPCCT in the detection of PM at different time of tumor growth in 16 rats inoculated with CC531 cells using dual-contrast injection protocols in two compartments (i.e. intravenous iodine and intraperitoneal gadolinium or the reverse protocol), compared to surgery. For all peritoneal regions and for both protocols, sensitivity was 69%, specificity was 100% and accuracy was 80%, and the correlation with surgical exploration was strong (p = 0.97; p = 0.0001). No significant difference was found in terms of diagnostic performance, quality of peritoneal opacification or diagnostic quality between the 2 injection protocols. We also showed poor vascularization of peritoneal metastases by measuring low concentrations of contrast agent in the largest lesions using SPCCT, which was confirmed by immunohistochemical analyses. In conclusion, SPCCT using dual-contrast agent injection protocols in 2 compartments is a promising imaging modality to assess the extent of PM in a rat model.
Collapse
|
18
|
Cuccione E, Chhour P, Si-Mohamed S, Dumot C, Kim J, Hubert V, Da Silva CC, Vandamme M, Chereul E, Balegamire J, Chevalier Y, Berthezène Y, Boussel L, Douek P, Cormode DP, Wiart M. Multicolor spectral photon counting CT monitors and quantifies therapeutic cells and their encapsulating scaffold in a model of brain damage. Nanotheranostics 2020; 4:129-141. [PMID: 32483519 PMCID: PMC7256015 DOI: 10.7150/ntno.45354] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 04/04/2020] [Indexed: 12/13/2022] Open
Abstract
Rationale & aim: Various types of cell therapies are currently under investigation for the treatment of ischemic stroke patients. To bridge the gap between cell administration and therapeutic outcome, there is a need for non-invasive monitoring of these innovative therapeutic approaches. Spectral photon counting computed tomography (SPCCT) is a new imaging modality that may be suitable for cell tracking. SPCCT is the next generation of clinical CT that allows the selective visualization and quantification of multiple contrast agents. The aims of this study are: (i) to demonstrate the feasibility of using SPCCT to longitudinally monitor and quantify therapeutic cells, i.e. bone marrow-derived M2-polarized macrophages transplanted in rats with brain damage; and (ii) to evaluate the potential of this approach to discriminate M2-polarized macrophages from their encapsulating scaffold. Methods: Twenty one rats received an intralesional transplantation of bone marrow-derived M2-polarized macrophages. In the first set of experiments, cells were labeled with gold nanoparticles and tracked for up to two weeks post-injection in a monocolor study via gold K-edge imaging. In the second set of experiments, the same protocol was repeated for a bicolor study, in which the labeled cells are embedded in iodine nanoparticle-labeled scaffold. The amount of gold in the brain was longitudinally quantified using gold K-edge images reconstructed from SPCCT acquisition. Animals were sacrificed at different time points post-injection, and ICP-OES was used to validate the accuracy of gold quantification from SPCCT imaging. Results: The feasibility of therapeutic cell tracking was successfully demonstrated in brain-damaged rats with SPCCT imaging. The imaging modality enabled cell monitoring for up to 2 weeks post-injection, in a specific and quantitative manner. Differentiation of labeled cells and their embedding scaffold was also feasible with SPCCT imaging, with a detection limit as low as 5,000 cells in a voxel of 250 × 250 × 250 µm in dimension in vivo. Conclusion: Multicolor SPCCT is an innovative translational imaging tool that allows monitoring and quantification of therapeutic cells and their encapsulating scaffold transplanted in the damaged rat brain.
Collapse
Affiliation(s)
- Elisa Cuccione
- CarMeN Laboratory, Institut National de la Santé et de la Recherche Médicale U1060, INRA U1397, Université Lyon 1, INSA Lyon, F-69600 Oullins, France
- VOXCAN, 1 avenue Bourgelat, 69280 Marcy l'Etoile, France
| | - Peter Chhour
- Department of Radiology, University of Pennsylvania, Pennsylvania, United States
| | - Salim Si-Mohamed
- CREATIS, CNRS UMR 5220 - INSERM U1206 - University of Lyon 1 - INSA Lyon, Lyon, France
- Hospices Civils de Lyon, Radiology Department, Lyon, France
| | - Chloé Dumot
- CarMeN Laboratory, Institut National de la Santé et de la Recherche Médicale U1060, INRA U1397, Université Lyon 1, INSA Lyon, F-69600 Oullins, France
| | - Johoon Kim
- Department of Radiology, University of Pennsylvania, Pennsylvania, United States
| | - Violaine Hubert
- CarMeN Laboratory, Institut National de la Santé et de la Recherche Médicale U1060, INRA U1397, Université Lyon 1, INSA Lyon, F-69600 Oullins, France
| | - Claire Crola Da Silva
- CarMeN Laboratory, Institut National de la Santé et de la Recherche Médicale U1060, INRA U1397, Université Lyon 1, INSA Lyon, F-69600 Oullins, France
| | - Marc Vandamme
- VOXCAN, 1 avenue Bourgelat, 69280 Marcy l'Etoile, France
| | | | - Joëlle Balegamire
- LAGEPP, University of Lyon 1, CNRS UMR 5007, 43 bd 11 Novembre, 69622 Villeurbanne, France
| | - Yves Chevalier
- LAGEPP, University of Lyon 1, CNRS UMR 5007, 43 bd 11 Novembre, 69622 Villeurbanne, France
| | - Yves Berthezène
- CREATIS, CNRS UMR 5220 - INSERM U1206 - University of Lyon 1 - INSA Lyon, Lyon, France
- Hospices Civils de Lyon, Radiology Department, Lyon, France
| | - Loïc Boussel
- CREATIS, CNRS UMR 5220 - INSERM U1206 - University of Lyon 1 - INSA Lyon, Lyon, France
- Hospices Civils de Lyon, Radiology Department, Lyon, France
| | - Philippe Douek
- CREATIS, CNRS UMR 5220 - INSERM U1206 - University of Lyon 1 - INSA Lyon, Lyon, France
- Hospices Civils de Lyon, Radiology Department, Lyon, France
| | - David P. Cormode
- Department of Radiology, University of Pennsylvania, Pennsylvania, United States
| | - Marlène Wiart
- CarMeN Laboratory, Institut National de la Santé et de la Recherche Médicale U1060, INRA U1397, Université Lyon 1, INSA Lyon, F-69600 Oullins, France
| |
Collapse
|
19
|
Feasibility of improving vascular imaging in the presence of metallic stents using spectral photon counting CT and K-edge imaging. Sci Rep 2019; 9:19850. [PMID: 31882698 PMCID: PMC6934567 DOI: 10.1038/s41598-019-56427-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 11/15/2019] [Indexed: 12/15/2022] Open
Abstract
Correct visualization of the vascular lumen is impaired in standard computed tomography (CT) because of blooming artifacts, increase of apparent size, induced by metallic stents and vascular calcifications. Recently, due to the introduction of photon-counting detectors in the X-ray imaging field, a new prototype spectral photon-counting CT (SPCCT) based on a modified clinical CT system has been tested in a feasibility study for improving vascular lumen delineation and visualization of coronary stent architecture. Coronary stents of different metal composition were deployed inside plastic tubes containing hydroxyapatite spheres to simulate vascular calcifications and in the abdominal aorta of one New Zealand White (NZW) rabbit. Imaging was performed with an SPCCT prototype, a dual-energy CT system, and a conventional 64-channel CT system (B64). We found the apparent widths of the stents significantly smaller on SPCCT than on the other two systems in vitro (p < 0.01), thus closer to the true size. Consequently, the intra-stent lumen was significantly larger on SPCCT (p < 0.01). In conclusion, owing to the increased spatial resolution of SPCCT, improved lumen visualization and delineation of stent metallic mesh is possible compared to dual-energy and conventional CT.
Collapse
|