1
|
Hogarth KA, Shkumat NA, Goman S, Amirabadi A, Bickford S, Muthusami P, Connolly BL, Maynes JT. Biomarkers of mitochondrial stress and DNA damage during pediatric catheter-directed neuroangiography - a prospective single-center study. Pediatr Radiol 2024; 54:1906-1918. [PMID: 39285018 DOI: 10.1007/s00247-024-06048-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 08/21/2024] [Accepted: 08/25/2024] [Indexed: 10/15/2024]
Abstract
BACKGROUND Neuroangiography represents a critical diagnostic and therapeutic imaging modality whose associated radiation may be of concern in children. The availability of in vivo radiation damage markers would represent a key advancement for understanding radiation effects and aid in the development of radioprotective strategies. OBJECTIVE Determine if biomarkers of cellular damage can be detected in the peripheral blood mononuclear cells (PBMC) of children undergoing neuroangiography. MATERIALS AND METHODS Prospective single-site study of 27 children. Blood collected pre and post neuroangiography, from which PBMC were isolated and assayed for biomarkers of mitochondrial stress (mitochondrial membrane potential (MMP), reactive oxygen species (ROS), and mitochondrial DNA (mtDNA)) and DNA damage (γH2AX). Dose response of biomarkers vs. radiation dose was analyzed using linear regressions. The cohort was divided into higher (HD) and lower dose (LD) groups and analyzed using linear mixed models and compared using Welch's t-tests. RESULTS No biomarker exhibited a dose-dependent response following radiation (γH2AX: R2 = 0.0012, P = 0.86; MMP: R2 = 0.016, P = 0.53; mtDNA: R2 = 0.10, P = 0.11; ROS: R2 = 0.0023, P = 0.81). Groupwise comparisons showed no significant differences in γH2AX or ROS after radiation (γH2AX: LD: 0.6 ± 6.0, P = 0.92; HD: -7.5 ± 6.3 AU, P = 0.24; ROS: LD: 1.3 ± 2.8, P = 0.64; HD: -3.6 ± 3.0 AU, P = 0.24). Significant changes were observed to mitochondrial markers MMP (-53.7 ± 14.7 AU, P = 0.0014) and mtDNA (-1.1 ± 0.4 AU, P = 0.0092) for HD, but not the LD group (MMP: 26.1 ± 14.7 AU, P = 0.090; mtDNA: 0.2 ± 0.4, P = 0.65). CONCLUSIONS Biomarkers of mitochondrial stress in PBMC were identified during pediatric neuroangiography and warrant further investigation for radiation biodosimetry. However, isolating radiation-specific effects from those of procedural stress and general anesthesia requires further investigation.
Collapse
Affiliation(s)
- Kaley A Hogarth
- Program in Molecular Medicine, SickKids Research Institute, Toronto, ON, Canada.
- Department of Anesthesia and Pain Medicine, The Hospital for Sick Children, 555 University Ave, Toronto, ON, M5G 1X8, Canada.
| | - Nicholas A Shkumat
- Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Simal Goman
- Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, ON, Canada
| | - Afsaneh Amirabadi
- Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, ON, Canada
| | - Suzanne Bickford
- Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, ON, Canada
- Paediatric Neurovascular Program, The Hospital for Sick Children, Toronto, ON, Canada
| | - Prakash Muthusami
- Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
- Paediatric Neurovascular Program, The Hospital for Sick Children, Toronto, ON, Canada
| | - Bairbre L Connolly
- Department of Diagnostic and Interventional Radiology, The Hospital for Sick Children, Toronto, ON, Canada.
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada.
- Medical Imaging, Hospital for Sick Children, 555 University Ave, Toronto, ON, M5G 1X8, Canada.
| | - Jason T Maynes
- Program in Molecular Medicine, SickKids Research Institute, Toronto, ON, Canada.
- Department of Anesthesia and Pain Medicine, The Hospital for Sick Children, 555 University Ave, Toronto, ON, M5G 1X8, Canada.
- Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto, ON, Canada.
- Department of Biochemistry, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
2
|
Villoria EM, Rocha TG, da Costa ICP, da Cruz TAS, Visconti MA. Letters. J Am Dent Assoc 2024; 155:643-644. [PMID: 38944801 DOI: 10.1016/j.adaj.2024.06.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 06/06/2024] [Indexed: 07/01/2024]
Affiliation(s)
- Eduardo Murad Villoria
- Professor, Professional Master's Program in Dental Clinic, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Thaiza Gonçalves Rocha
- PhD Student, Department of Pathology and Oral Diagnosis, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | | | - Maria Augusta Visconti
- Professor, Department of Pathology and Oral Diagnosis, School of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
3
|
Jadhav TS, Sansare K, Sreenivasan V, Unnikrishnan A, Vahanwala S. A systematic review and meta-analysis of the genotoxic and cytotoxic effects on oral epithelium induced by cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 2024; 138:324-334. [PMID: 38570275 DOI: 10.1016/j.oooo.2024.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 02/13/2024] [Accepted: 03/03/2024] [Indexed: 04/05/2024]
Abstract
OBJECTIVE To evaluate the occurrence of genotoxic and cytotoxic effects in oral epithelium after exposure of patients to cone beam computed tomography (CBCT). METHODS A systematic review (SR) was conducted following the PECO (Population, Exposure, Comparison, Outcome) criteria. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO). A search was performed on the PubMed, Scopus, ScienceDirect, and Google Scholar databases. Effect size and heterogeneity of data were evaluated statistically. The Joanna Briggs Institute questionnaire for observational studies was utilized to assess the risk of bias. The GRADE tool was applied for the assessment of the quality of evidence. Begg's funnel plot was used to evaluate publication bias. RESULTS In total, 10 full-text articles were included in the SR, with 6 of them in the meta-analysis. The SR showed a significant increase in micronuclei after exposure, with a large effect size of 1.03. For genotoxicity, the tau2 for heterogeneity was 0.96, the chi-squared test for heterogeneity P < .00001, the I2 statistics for random effects was 91%, and the overall effect for Z value was 2.46 (P = .01). The risk of bias was low, the quality of evidence was strong, and publication bias was absent. CONCLUSION CBCT can cause genotoxicity in the oral epithelium with a large effect size. The measure of cytotoxicity after CBCT exposure was not possible due to the lack of homogeneity of the included articles.
Collapse
Affiliation(s)
- Tanushree S Jadhav
- Oral Medicine and Maxillofacial Radiology, Nair Hospital Dental College, Mumbai, India.
| | - Kaustubh Sansare
- Oral Medicine and Maxillofacial Radiology, Nair Hospital Dental College, Mumbai, India
| | - Venkatraman Sreenivasan
- Oral Medicine and Maxillofacial Radiology, Bharathi Vidyapeeth Dental College and Hospital, Navi Mumbai, India
| | - Aswathi Unnikrishnan
- Oral Medicine and Maxillofacial Radiology, Nair Hospital Dental College, Mumbai, India
| | - Sonal Vahanwala
- Oral Medicine and Maxillofacial Radiology, Nair Hospital Dental College, Mumbai, India
| |
Collapse
|
4
|
Santos AA, de Freitas Silva BS, Correia FFN, Mezaiko E, de Souza Roriz CF, Silva MAG, Freitas DQ, Yamamoto-Silva FP. Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance. Imaging Sci Dent 2024; 54:159-169. [PMID: 38948188 PMCID: PMC11211023 DOI: 10.5624/isd.20230251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/11/2024] [Accepted: 01/11/2024] [Indexed: 07/02/2024] Open
Abstract
Purpose The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.
Collapse
Affiliation(s)
- Ananda Amaral Santos
- Department of Oral Radiology, University of Anápolis, Anápolis, GO, Brazil
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | - Brunno Santos de Freitas Silva
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
- Science Program in Dentistry, University of Anápolis, Anápolis, GO, Brazil
| | | | - Eleazar Mezaiko
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | | | - Maria Alves Garcia Silva
- Department of Oral Radiology, University of Anápolis, Anápolis, GO, Brazil
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
| | - Deborah Queiroz Freitas
- Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, São Paulo, Brazil
| | - Fernanda Paula Yamamoto-Silva
- Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil
- Science Program in Dentistry, University of Anápolis, Anápolis, GO, Brazil
| |
Collapse
|
5
|
Benavides E, Krecioch JR, Connolly RT, Allareddy T, Buchanan A, Spelic D, O'Brien KK, Keels MA, Mascarenhas AK, Duong ML, Aerne-Bowe MJ, Ziegler KM, Lipman RD. Optimizing radiation safety in dentistry: Clinical recommendations and regulatory considerations. J Am Dent Assoc 2024; 155:280-293.e4. [PMID: 38300176 DOI: 10.1016/j.adaj.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 11/20/2023] [Accepted: 12/12/2023] [Indexed: 02/02/2024]
Abstract
BACKGROUND The value of dental radiographs to oral health care decision making must be balanced with radiation safety to minimize patient exposure and occupational risk of oral health care providers. This review summarizes recommendations and regulatory guidance regarding dental radiography and cone-beam computed tomography. An expert panel presents recommendations on radiation safety, appropriate imaging practices, and reducing radiation exposure. TYPES OF STUDIES REVIEWED A systematic search run in Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews identified relevant topical systematic reviews, organizational guidelines, and regulatory reviews published in the peer-reviewed literature since 2010. A supplemental search of the gray literature (eg, technical reports, standards, and regulations) identified topical nonindexed publications. Inclusion criteria required relevance to primary oral health care (ie, general or pediatric dentistry). RESULTS A total of 95 articles, guidance documents, and regulations met the inclusion criteria. Resources were characterized as applicable to all modalities, operator and occupational protection, dose reduction and optimization, and quality assurance and control. PRACTICAL IMPLICATIONS Understanding factors affecting imaging safety and applying fundamental principles of radiation protection consistent with federal, state, and local requirements are essential for limiting patient ionizing radiation exposure, in conjunction with implementing optimal imaging procedures to support prudent use of dental radiographs and cone-beam computed tomographic imaging. The regulatory guidance and best practice recommendations summarized in this article should be followed by dentists and other oral health care providers.
Collapse
|
6
|
Pálvölgyi L, Kesztyűs A, Shujaat S, Jacobs R, Nagy K. Creation of Dimicleft radiological cleft phantom skulls using reversed virtual planning technique. Dentomaxillofac Radiol 2023; 52:20230121. [PMID: 37395648 PMCID: PMC10552124 DOI: 10.1259/dmfr.20230121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/12/2023] [Accepted: 05/17/2023] [Indexed: 07/04/2023] Open
Abstract
OBJECTIVES The aim of this technical report was to develop customized pediatric phantoms for cone-beam computed tomography (CBCT)-related research in cleft patients. METHODS Six human pediatric skulls (age: 5-10 years) were recruited. A cone-beam computed tomography (CBCT) scan was taken for each skull, followed by virtual modeling through the process of segmentation. An artificial cleft was designed and printed to be applied onto the skull for the creation of an artificial cleft. The skulls were covered with non-radiopaque tape and immersed in melted Mix-D soft tissue equivalent material. The resulting phantoms covered with Mix-D were assessed radiologically by two expert radiologists. These phantoms were referred to as Dimicleft pediatric skull phantoms. RESULTS Dimicleft phantoms were able to appropriately mimic in vivo circumstances. No gaps existed between Mix-D and bony tissue. Virtual planning allowed the optimal designing of an artificial cleft onto the phantom. The artificially created cleft was suitable to determine the size, location, and extent of the cleft. CONCLUSIONS Dimicleft phantoms could act as a viable alternative to other commercially available options for assessing image quality and optimizing CBCT protocols in cleft patients for diagnostics and three-dimensional treatment planning.
Collapse
Affiliation(s)
- Laura Pálvölgyi
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| | - Artúr Kesztyűs
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| | | | | | - Krisztián Nagy
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| |
Collapse
|
7
|
Yeung AWK, Parvanov ED, Horbańczuk JO, Kletecka-Pulker M, Kimberger O, Willschke H, Atanasov AG. Are dental x-rays safe? Content analysis of English and Chinese YouTube videos. Digit Health 2023; 9:20552076231179053. [PMID: 37312949 PMCID: PMC10259113 DOI: 10.1177/20552076231179053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 05/12/2023] [Indexed: 06/15/2023] Open
Abstract
Objective This study provided a content analysis of English and Chinese YouTube videos related to dental radiation safety. Method The search string, entered in English and Chinese respectively, was: (dental x-ray safe). The searches were performed and exported with Apify YouTube scraper. By screening the resultant videos and their related videos (as recommended by YouTube), a total of 89 videos were screened. Finally, 45 videos (36 English and nine Chinese) were included and analyzed. The specific information regarding dental radiation was evaluated. The Patient Education Material Assessment Tool for Audiovisual Materials was used to assess understandability and actionability. Results There was no significant difference between the English and Chinese videos in terms of view count, like count, comment count, and video duration. Half of the videos explicitly reassured the audience that dental x-rays are safe. Two of the English videos specifically stated that dental x-rays do not cause cancers. Numerous analogies were made in regard to radiation dose, such as equivalence to taking a flight or eating some bananas. About 41.7% of the English videos and 33.3% of the Chinese videos mentioned that patients could be further protected from scatter radiation by wearing a lead apron and thyroid collar. Videos had a good understandability score (91.3) but a poor actionability score (0). Conclusions Some of the analogies and the claimed radiation dose were questionable. One Chinese video even wrongly stated that dental x-rays are nonionizing radiation. The videos generally did not mention their information sources or the underlying radiation protection principles.
Collapse
Affiliation(s)
- Andy Wai Kan Yeung
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
- Ludwig Boltzmann Institute for Digital Health and Patient Safety, Medical University of Vienna, Vienna, Austria
| | - Emil D Parvanov
- Ludwig Boltzmann Institute for Digital Health and Patient Safety, Medical University of Vienna, Vienna, Austria
- Department of Translational Stem Cell Biology, Research Institute of the Medical University of Varna, Varna, Bulgaria
| | - Jarosław Olav Horbańczuk
- Institute of Genetics and Animal Biotechnology of the Polish Academy of Sciences, Jastrzebiec, Magdalenka, Poland
| | - Maria Kletecka-Pulker
- Ludwig Boltzmann Institute for Digital Health and Patient Safety, Medical University of Vienna, Vienna, Austria
- Institute for Ethics and Law in Medicine, University of Vienna, Vienna, Austria
| | - Oliver Kimberger
- Ludwig Boltzmann Institute for Digital Health and Patient Safety, Medical University of Vienna, Vienna, Austria
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University Vienna, Vienna, Austria
| | - Harald Willschke
- Ludwig Boltzmann Institute for Digital Health and Patient Safety, Medical University of Vienna, Vienna, Austria
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University Vienna, Vienna, Austria
| | - Atanas G Atanasov
- Ludwig Boltzmann Institute for Digital Health and Patient Safety, Medical University of Vienna, Vienna, Austria
- Institute of Genetics and Animal Biotechnology of the Polish Academy of Sciences, Jastrzebiec, Magdalenka, Poland
| |
Collapse
|
8
|
Hung K, Hui L, Yeung AWK, Jacobs R, Leung YY, Bornstein M. An analysis of patient dose received during cone beam computed tomography in relation to scan settings and imaging indications as seen in a dental institution in order to establish institutional diagnostic reference levels. Dentomaxillofac Radiol 2022; 51:20200529. [PMID: 35230883 PMCID: PMC10043612 DOI: 10.1259/dmfr.20200529] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To investigate the dose-area product (DAP) of cone-beam computed tomography (CBCT) examinations for different scan settings and imaging indications, and to establish institutional diagnostic reference levels (DRLs) for dose optimization. METHODS A retrospective analysis of the DAP values of 3568 CBCT examinations taken from two different devices at the Prince Philip Dental Hospital, Hong Kong between 2016 and 2021 was performed. Patient- (age, gender, and imaging indication) and imaging-related (CBCT device, field-of-view (FOV), and voxel size) were correlated with the DAPs. The indication-oriented third-quartile DAP values were compared with DRLs from the UK, Finland, and Switzerland. The obtained third-quartile DAPs lower than the national DRLs and those for which no national DRLs have been proposed were used to establish institutional DRLs. RESULTS In the investigated CBCTs, the DAP value for large FOV scans was significantly lower than medium/small FOVs. CBCTs with a small voxel size exhibited a significantly higher DAP than those with a medium/large voxel size. CBCTs for endodontic, periodontal, orthodontic, or orthognathic evaluation exhibited a significantly higher DAP than other indications. Twelve indication-oriented institutional DRLs were established and five of them were lower than the national DRLs: third molars (229 mGy×cm2), jaw cysts/tumors (410 mGy×cm2), maxillary sinus pathology (520 mGy×cm2), developing dentition (164 mGy×cm2), and periapical lesions (564 mGy×cm2). CONCLUSIONS CBCT examinations for endodontic, periodontal, orthodontic, or orthognathic evaluation may deliver a higher radiation dose to the patient than other imaging tasks. A periodic review of the patient dose from CBCT imaging and establishment of institutional DRLs for specific clinical settings are needed for monitoring patient dose and to optimize indication-oriented scanning protocols.
Collapse
Affiliation(s)
- Kuofeng Hung
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Liuling Hui
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Andy Wai Kan Yeung
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Reinhilde Jacobs
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven and Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Yiu Yan Leung
- Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Michael Bornstein
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China.,Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| |
Collapse
|
9
|
Inflammatory dentigerous cyst following unresolved endodontic infection of deciduous teeth: A report of three cases with CBCT imaging. PEDIATRIC DENTAL JOURNAL 2022. [DOI: 10.1016/j.pdj.2021.12.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
10
|
Dicu T, Virag P, Brie I, Perde-Schrepler M, Fischer-Fodor E, Victor B, Cucoș A, Burghele BD. A comparative study of genotoxicity endpoints for women exposed to different levels of indoor radon concentrations. Int J Radiat Biol 2021; 98:18-29. [PMID: 34586971 DOI: 10.1080/09553002.2021.1987559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND AND PURPOSE Radon and its radioactive progenies are the most important source of ionizing radiation of natural origin, being classified as a Group 1 carcinogen. The aim of this study is to investigate the genotoxic effects of a wide range of indoor radon concentrations, as well as the kinetics of the process of repairing DNA-induced lesions by a challenging dose of gamma irradiation. MATERIAL AND METHODS Female subjects residing in the Băiţa-Ştei radon priority area were selected as the exposed group. The reference group was comprised of women from the same county (Bihor), but located in an area with an average indoor radon concentration typical of the county from which they were taken. Radon concentration values of 300 Bq/m3 and 148 Bq/m3, respectively, were chosen as a threshold in order to capture the impact of radon exposure between the groups. The alkaline comet assay was used in order to measure the DNA damage, as well as the repair kinetics at 2 and 24 h after 2 Gy challenging doses of gamma irradiation using peripheral blood lymphocytes. From the serum of the subjects, the oxidative damage by 8-hydroxydeoxyguanosine as well as the PARP induction was evaluated. The chromosomal aberrations were evaluated using the Cytokinesis Block MicroNucleus Assay. RESULTS A statistically significant increase was observed in terms of DNA-induced lesions assessed by comet assay for the exposed group compared to the reference group. A positive correlation was obtained between DNA damage and the annual effective dose, respectively with the radon progenies concentrations. A statistically significant difference was also observed for the frequency of the micronuclei between the exposed - reference groups. Significantly faster repair kinetics of DNA-induced lesions was recorded for the first 2 h after gamma irradiation in the reference group compared to the exposed group. Using the threshold of 300 Bq/m3 for radon concentration, faster kinetics of DNA damage repair for people exposed to low radon concentrations, compared to those exposed to higher concentrations for the second phase of DNA repair kinetics was observed. CONCLUSION An increased radiosensitivity of lymphocytes, as well as slower repair kinetics, may be associated with exposure to higher indoor radon concentrations.
Collapse
Affiliation(s)
- Tiberius Dicu
- "Constantin Cosma" Radon Laboratory (LiRaCC), Faculty of Environmental Science and Engineering, "Babeş-Bolyai" University, Cluj-Napoca, Romania
| | - Piroska Virag
- The Oncology Institute Prof. Dr. I. Chiricuţă, Cluj-Napoca, Romania
| | - Ioana Brie
- The Oncology Institute Prof. Dr. I. Chiricuţă, Cluj-Napoca, Romania
| | | | | | - Bogdan Victor
- The Oncology Institute Prof. Dr. I. Chiricuţă, Cluj-Napoca, Romania
| | - Alexandra Cucoș
- "Constantin Cosma" Radon Laboratory (LiRaCC), Faculty of Environmental Science and Engineering, "Babeş-Bolyai" University, Cluj-Napoca, Romania
| | - Bety-Denissa Burghele
- "Constantin Cosma" Radon Laboratory (LiRaCC), Faculty of Environmental Science and Engineering, "Babeş-Bolyai" University, Cluj-Napoca, Romania
| |
Collapse
|
11
|
Belmans N, Oenning AC, Salmon B, Baselet B, Tabury K, Lucas S, Lambrichts I, Moreels M, Jacobs R, Baatout S. Radiobiological risks following dentomaxillofacial imaging: should we be concerned? Dentomaxillofac Radiol 2021; 50:20210153. [PMID: 33989056 PMCID: PMC8404518 DOI: 10.1259/dmfr.20210153] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 04/22/2021] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVES This review aimed to present studies that prospectively investigated biological effects in patients following diagnostic dentomaxillofacial radiology (DMFR). METHODS Literature was systematically searched to retrieve all studies assessing radiobiological effects of using X-ray imaging in the dentomaxillofacial area, with reference to radiobiological outcomes for other imaging modalities and fields. RESULTS There is a lot of variability in the reported radiobiological assessment methods and radiation dose measures, making comparisons of radiobiological studies challenging. Most radiological DMFR studies are focusing on genotoxicity and cytotoxicity, data for 2D dentomaxillofacial radiographs, albeit with some methodological weakness biasing the results. For CBCT, available evidence is limited and few studies include comparative data on both adults and children. CONCLUSIONS In the future, one will have to strive towards patient-specific measures by considering age, gender and other individual radiation sensitivity-related factors. Ultimately, future radioprotection strategies should build further on the concept of personalized medicine, with patient-specific optimization of the imaging protocol, based on radiobiological variables.
Collapse
Affiliation(s)
| | - Anne Caroline Oenning
- Division of Oral Radiology, Faculdade São Leopoldo Mandic, Instituto de Pesquisas São, Leopoldo Mandic, Campinas, Sao Paulo, Brazil
| | | | - Bjorn Baselet
- Belgian Nuclear Research Centre (SCK CEN), Radiobiology Unit, Boeretang 200, Mol, Belgium
| | | | - Stéphane Lucas
- Laboratory of Analysis by Nuclear Reaction (LARN/PMR), Namur Research Institute for Life Sciences, University of Namur, Namur, Belgium
| | - Ivo Lambrichts
- Morphology Group, Biomedical Research Institute, Hasselt University, Agoralaan Building C, Diepenbeek, Belgium
| | - Marjan Moreels
- Belgian Nuclear Research Centre (SCK CEN), Radiobiology Unit, Boeretang 200, Mol, Belgium
| | | | | |
Collapse
|
12
|
Oenning AC, Jacobs R, Salmon B. ALADAIP, beyond ALARA and towards personalized optimization for paediatric cone-beam CT. Int J Paediatr Dent 2021; 31:676-678. [PMID: 33844356 DOI: 10.1111/ipd.12797] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 03/31/2021] [Accepted: 04/03/2021] [Indexed: 12/17/2022]
Affiliation(s)
- Anne Caroline Oenning
- Orofacial Pathologies, Imaging and Biotherapies UR2496 Lab, Faculté de Chirurgie Dentaire, Université de Paris, Montrouge, France.,Division of Oral Radiology, Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, Brazil
| | - Reinhilde Jacobs
- OMFS-IMPATH research group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - Benjamin Salmon
- Orofacial Pathologies, Imaging and Biotherapies UR2496 Lab, Faculté de Chirurgie Dentaire, Université de Paris, Montrouge, France.,Dental Medicine Department, Bretonneau Hospital, AP-HP, Paris, France
| | | |
Collapse
|
13
|
Izaaryene J, Golin M, Daidj N, Piana G, Ferre M. A study of dose indicators during intra-arterial catheter implantation for liver chemotherapy. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:495-511. [PMID: 33827058 DOI: 10.1088/1361-6498/abf570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 04/07/2021] [Indexed: 06/12/2023]
Abstract
The aim of the present study was to describe patient dose indicator levels during intra-arterial catheter (IAC) implantation for liver chemotherapy, and to determine factors affecting the dose indicators. Between January 2017 and January 2019, 61 patients with hepatic metastases from colorectal cancer were retrospectively included. Interventions were carried out in a standardised manner by three experienced radiologists on the same angiographic table without changes in protocol parameters. For each patient, clinical, radiological and dosimetry data were collected, including the air kerma area product (KAP), part of KAP due to the fluoroscopy and fluoroscopy time (FT), total kerma at the reference interventional point and peak skin dose (PSD). Local dose reference levels (RLs) were determined as the third quartile of the patient dose distributions. Univariate and multivariate analysis of factors affecting dose indicators was performed. The mean KAP was 111 Gy cm2, the mean reference point air kerma (Ka,r) was 648 mGy, the mean PSD was 613 mGy, and the mean FT was 3190 s (62% of the KAP). The mean cone beam computed tomography dose was 37.3 ± 11.8 Gy cm2, which accounted for 37% of the KAP. The RL could be proposed taking into account the third quartiles (KAP = 164.6 Gy cm2, Ka,r = 904.5 mGy, FT = 4011 s and standard deviation = 772.7 mGy). The factors affecting dose indicators were related to the patients (sex, cardiovascular risk factors, weight, body mass index), to the vascular anatomies (coeliac trunk angulation) and to the procedures (number of embolised arteries). This study allowed a better understanding of dose indicators and factors affecting these indicators during the implantation of IACs for hepatic chemotherapy, which is a long and difficult procedure. Local dose RLs were determined. Multicentre, multi-equipment studies are necessary.
Collapse
Affiliation(s)
- Jean Izaaryene
- Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France
- Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France
| | - Melissa Golin
- Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France
- Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France
| | - Nassima Daidj
- Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France
- Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France
| | - Gilles Piana
- Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France
- Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France
| | - Marjorie Ferre
- Department of Radiology, Institut Paoli Calmettes, 232 Boulevard Sainte Marguerite, Marseille 13009, France
- Aix Marseille University, Jardin du Pharo, 58 Boulevard Charles Livon, Marseille 13007, France
| |
Collapse
|
14
|
Van Gorp G, Lambrechts M, Jacobs R, Declerck D. Paediatric dentist's ability to detect and diagnose dental trauma using 2D versus 3D imaging. Eur Arch Paediatr Dent 2021; 22:699-705. [PMID: 33713318 DOI: 10.1007/s40368-021-00611-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 02/26/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Visualisation of the third dimension has been reported to increase effectiveness of correctly diagnosing traumatic dental injuries. AIM To assess the ability of paediatric dentists to detect and diagnose Traumatic Dental Injuries (TDI) using two different imaging modalities, intraoral radiographs (2D) and CBCT scans (3D). In addition, observer's confidence regarding the obtained diagnosis, using either technique, was assessed. MATERIAL AND METHODS Both 2D and 3D images of 20 dental trauma cases in children were presented in random order to a panel of thirteen paediatric dentists. Observers received instructions for the screening of the images for radiographic findings related to dental trauma, using structured scoring sheets for 2D and 3D images. Observed data were compared to those recorded by two experienced benchmark observers. A ten-point scale was used for assessing observer's confidence regarding their final diagnosis using 2D versus 3D images. RESULTS Performance of individual observers showed wide variation. Statistical significance was reached for correctly detected and correctly diagnosed findings (p = 0.02), in favor of 3D. Most of the observers reported comparable confidence using 2D and 3D, two observers were more confident using 3D and one observer was more confident using 2D. CONCLUSIONS Paediatric dentist's ability to detect and diagnose findings in patients with TDI was higher on 3D images. Most observers showed a similar confidence score of their diagnostic performance both on 2D and on 3D.
Collapse
Affiliation(s)
- G Van Gorp
- Department of Oral Health Sciences and Department of Dentistry, Unit of Paediatric Dentistry and Special Dental Care, KU Leuven, University Hospitals Leuven, Kapucijnenvoer 7, PO box 7001, B-3000, Leuven, Belgium.
| | - M Lambrechts
- Department of Oral Health Sciences and Department of Dentistry, Unit of Paediatric Dentistry and Special Dental Care, KU Leuven, University Hospitals Leuven, Kapucijnenvoer 7, PO box 7001, B-3000, Leuven, Belgium
| | - R Jacobs
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department Dental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - D Declerck
- Department of Oral Health Sciences and Department of Dentistry, Unit of Paediatric Dentistry and Special Dental Care, KU Leuven, University Hospitals Leuven, Kapucijnenvoer 7, PO box 7001, B-3000, Leuven, Belgium
| |
Collapse
|
15
|
Ciocan-Cartita CA, Jurj A, Zanoaga O, Cojocneanu R, Pop LA, Moldovan A, Moldovan C, Zimta AA, Raduly L, Pop-Bica C, Buse M, Budisan L, Virag P, Irimie A, Diaz SMG, Berindan-Neagoe I, Braicu C. New insights in gene expression alteration as effect of doxorubicin drug resistance in triple negative breast cancer cells. J Exp Clin Cancer Res 2020; 39:241. [PMID: 33187552 PMCID: PMC7664031 DOI: 10.1186/s13046-020-01736-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 10/14/2020] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Triple negative breast cancer (TNBC) is a heterogeneous disease with aggressive behavior and an unfavorable prognosis rate. Due to the lack of surface receptors, TNBC must be intensely investigated in order to establish a suitable treatment for patients with this pathology. Chemoresistance is an important reason for therapeutic failure in TNBC. METHOD The aim of this study was to investigate the effect of doxorubicin in TNBC cell lines and to highlight cellular and molecular alterations after a long exposure to doxorubicin. RESULTS The results revealed that doxorubicin significantly increased the half maximal inhibitory concentration (IC50) values at P12 and P24 compared to parenteral cells P0. Modifications in gene expression were investigated through microarray technique, and for detection of mutational pattern was used Next Generation Sequencing (NGS). 196 upregulated and 115 downregulated genes were observed as effect of multiple dose exposure, and 15 overexpressed genes were found to be involved in drug resistance. Also, the presence of some additional mutations in both cell lines was observed. CONCLUSION The outcomes of this research may provide novel biomarkers for drug resistance in TNBC. Also, this activity can highlight the potential mechanisms associated with drug resistance, as well as the potential therapies to counteract these mechanisms.
Collapse
Affiliation(s)
- Cristina Alexandra Ciocan-Cartita
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Ancuta Jurj
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Oana Zanoaga
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Roxana Cojocneanu
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Laura-Ancuta Pop
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alin Moldovan
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Cristian Moldovan
- MedFuture Research Center for Advanced Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alina Andreea Zimta
- MedFuture Research Center for Advanced Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Lajos Raduly
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Cecilia Pop-Bica
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Mihail Buse
- MedFuture Research Center for Advanced Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Liviuta Budisan
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Piroska Virag
- Laboratory of Radiotherapy, Radiobiology and Tumor Biology, “Prof. Dr. Ion Chiricuta” Oncology Institute, Cluj-Napoca, Romania
| | - Alexandru Irimie
- Department of Surgical Oncology and Gynecological Oncology, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
- Department of Surgery, “Prof. Dr. Ion Chiricuta” Oncology Institute, Cluj-Napoca, Romania
| | - Sandra Martha Gomez Diaz
- Brazilian Biosciences National Laboratory (LNBio), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas, Sao Paulo 13083-970 Brazil
| | - Ioana Berindan-Neagoe
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
- Department of Functional Genomics and Experimental Pathology, “Prof. Dr. Ion Chiricuta” Oncology Institute, Cluj-Napoca, Romania
| | - Cornelia Braicu
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|