1
|
Li J, Chu H, Chen Z, Yiu CK, Qu Q, Li Z, Yu X. Recent Advances in Materials, Devices and Algorithms Toward Wearable Continuous Blood Pressure Monitoring. ACS NANO 2024; 18:17407-17438. [PMID: 38923501 DOI: 10.1021/acsnano.4c04291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Continuous blood pressure (BP) tracking provides valuable insights into the health condition and functionality of the heart, arteries, and overall circulatory system of humans. The rapid development in flexible and wearable electronics has significantly accelerated the advancement of wearable BP monitoring technologies. However, several persistent challenges, including limited sensing capabilities and stability of flexible sensors, poor interfacial stability between sensors and skin, and low accuracy in BP estimation, have hindered the progress in wearable BP monitoring. To address these challenges, comprehensive innovations in materials design, device development, system optimization, and modeling have been pursued to improve the overall performance of wearable BP monitoring systems. In this review, we highlight the latest advancements in flexible and wearable systems toward continuous noninvasive BP tracking with a primary focus on materials development, device design, system integration, and theoretical algorithms. Existing challenges, potential solutions, and further research directions are also discussed to provide theoretical and technical guidance for the development of future wearable systems in continuous ambulatory BP measurement with enhanced sensing capability, robustness, and long-term accuracy.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Hongwei Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China
| | - Zhenlin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qing'ao Qu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zhiyuan Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
- Hong Kong Institute for Clean Energy, City University of Hong Kong, Kowloon, Hong Kong, China
| |
Collapse
|
2
|
Huang S, Jafari R, Mortazavi BJ. Pulse2AI: An Adaptive Framework to Standardize and Process Pulsatile Wearable Sensor Data for Clinical Applications. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2024; 5:330-338. [PMID: 38899025 PMCID: PMC11186651 DOI: 10.1109/ojemb.2024.3398444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/09/2024] [Accepted: 04/19/2024] [Indexed: 06/21/2024] Open
Abstract
Goal: To establish Pulse2AI as a reproducible data preprocessing framework for pulsatile signals that generate high-quality machine-learning-ready datasets from raw wearable recordings. Methods: We proposed an end-to-end data preprocessing framework that adapts multiple pulsatile signal modalities and generates machine-learning-ready datasets agnostic to downstream medical tasks. Results: a dataset preprocessed by Pulse2AI improved systolic blood pressure estimation by 29.58%, from 11.41 to 8.03 mmHg in root-mean-square-error (RMSE) and its diastolic counterpart by 26.01%, from 7.93 to 5.87 mmHg in RMSE. For respiration rate (RR) estimation, Pulse2AI boosted performance by 19.69%, from 1.47 to 1.18 breaths per minute (BrPM) in mean-absolute-error (MAE). Conclusion: Pulse2AI turns pulsatile signals into machine learning (ML) ready datasets for arbitrary remote health monitoring tasks. We tested Pulse2AI on multiple pulsatile modalities and demonstrated its efficacy in two medical applications. This work bridges valuable assets in remote sensing and internet of medical things to ML-ready datasets for medical modeling.
Collapse
Affiliation(s)
- Sicong Huang
- Department of Computer Science and EngineeringTexas A&M UniversityCollege StationTX77840USA
| | - Roozbeh Jafari
- Lincoln LaboratoryMassachusetts Institute of TechnologyLexingtonMA02139USA
- Laboratory for Information and Decision Systems (LIDS)Massachusetts Institute of TechnologyCambridgeMA02139USA
- Department of Electrical and Computer EngineeringTexas A&M UniversityCollege StationTX77843USA
- School of Engineering MedicineTexas A&M UniversityHoustonTX77843USA
| | - Bobak J. Mortazavi
- Department of Computer Science and EngineeringTexas A&M UniversityCollege StationTX77840USA
| |
Collapse
|
3
|
Matthews J, Soltis I, Villegas‐Downs M, Peters TA, Fink AM, Kim J, Zhou L, Romero L, McFarlin BL, Yeo W. Cloud-Integrated Smart Nanomembrane Wearables for Remote Wireless Continuous Health Monitoring of Postpartum Women. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307609. [PMID: 38279514 PMCID: PMC10987106 DOI: 10.1002/advs.202307609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 12/15/2023] [Indexed: 01/28/2024]
Abstract
Noncommunicable diseases (NCD), such as obesity, diabetes, and cardiovascular disease, are defining healthcare challenges of the 21st century. Medical infrastructure, which for decades sought to reduce the incidence and severity of communicable diseases, has proven insufficient in meeting the intensive, long-term monitoring needs of many NCD disease patient groups. In addition, existing portable devices with rigid electronics are still limited in clinical use due to unreliable data, limited functionality, and lack of continuous measurement ability. Here, a wearable system for at-home cardiovascular monitoring of postpartum women-a group with urgently unmet NCD needs in the United States-using a cloud-integrated soft sternal device with conformal nanomembrane sensors is introduced. A supporting mobile application provides device data to a custom cloud architecture for real-time waveform analytics, including medical device-grade blood pressure prediction via deep learning, and shares the results with both patient and clinician to complete a robust and highly scalable remote monitoring ecosystem. Validated in a month-long clinical study with 20 postpartum Black women, the system demonstrates its ability to remotely monitor existing disease progression, stratify patient risk, and augment clinical decision-making by informing interventions for groups whose healthcare needs otherwise remain unmet in standard clinical practice.
Collapse
Affiliation(s)
- Jared Matthews
- IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and NanotechnologyGeorgia Institute of TechnologyAtlantaGA30332USA
- George W. Woodruff School of Mechanical EngineeringGeorgia Institute of TechnologyAtlantaGA30332USA
| | - Ira Soltis
- IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and NanotechnologyGeorgia Institute of TechnologyAtlantaGA30332USA
- George W. Woodruff School of Mechanical EngineeringGeorgia Institute of TechnologyAtlantaGA30332USA
| | - Michelle Villegas‐Downs
- Department of Human Development Nursing ScienceCollege of NursingUniversity of Illinois Chicago845 S. Damen Ave., MC 802ChicagoIL60612USA
| | - Tara A. Peters
- Department of Human Development Nursing ScienceCollege of NursingUniversity of Illinois Chicago845 S. Damen Ave., MC 802ChicagoIL60612USA
| | - Anne M. Fink
- Department of Biobehavioral Nursing ScienceCollege of NursingUniversity of Illinois Chicago845 S. Damen Ave., MC 802ChicagoIL60612USA
| | - Jihoon Kim
- IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and NanotechnologyGeorgia Institute of TechnologyAtlantaGA30332USA
- George W. Woodruff School of Mechanical EngineeringGeorgia Institute of TechnologyAtlantaGA30332USA
| | - Lauren Zhou
- IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and NanotechnologyGeorgia Institute of TechnologyAtlantaGA30332USA
- George W. Woodruff School of Mechanical EngineeringGeorgia Institute of TechnologyAtlantaGA30332USA
| | - Lissette Romero
- IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and NanotechnologyGeorgia Institute of TechnologyAtlantaGA30332USA
- George W. Woodruff School of Mechanical EngineeringGeorgia Institute of TechnologyAtlantaGA30332USA
| | - Barbara L. McFarlin
- Department of Human Development Nursing ScienceCollege of NursingUniversity of Illinois Chicago845 S. Damen Ave., MC 802ChicagoIL60612USA
| | - Woon‐Hong Yeo
- IEN Center for Wearable Intelligent Systems and Healthcare at the Institute for Electronics and NanotechnologyGeorgia Institute of TechnologyAtlantaGA30332USA
- George W. Woodruff School of Mechanical EngineeringGeorgia Institute of TechnologyAtlantaGA30332USA
- Wallace H. Coulter Department of Biomedical EngineeringGeorgia Tech and Emory University School of MedicineAtlantaGA30332USA
- Parker H. Petit Institute for Bioengineering and BiosciencesInstitute for MaterialsInstitute for Robotics and Intelligent MachinesGeorgia Institute of TechnologyAtlantaGA30332USA
| |
Collapse
|
4
|
Li H, Tan P, Rao Y, Bhattacharya S, Wang Z, Kim S, Gangopadhyay S, Shi H, Jankovic M, Huh H, Li Z, Maharjan P, Wells J, Jeong H, Jia Y, Lu N. E-Tattoos: Toward Functional but Imperceptible Interfacing with Human Skin. Chem Rev 2024; 124:3220-3283. [PMID: 38465831 DOI: 10.1021/acs.chemrev.3c00626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
The human body continuously emits physiological and psychological information from head to toe. Wearable electronics capable of noninvasively and accurately digitizing this information without compromising user comfort or mobility have the potential to revolutionize telemedicine, mobile health, and both human-machine or human-metaverse interactions. However, state-of-the-art wearable electronics face limitations regarding wearability and functionality due to the mechanical incompatibility between conventional rigid, planar electronics and soft, curvy human skin surfaces. E-Tattoos, a unique type of wearable electronics, are defined by their ultrathin and skin-soft characteristics, which enable noninvasive and comfortable lamination on human skin surfaces without causing obstruction or even mechanical perception. This review article offers an exhaustive exploration of e-tattoos, accounting for their materials, structures, manufacturing processes, properties, functionalities, applications, and remaining challenges. We begin by summarizing the properties of human skin and their effects on signal transmission across the e-tattoo-skin interface. Following this is a discussion of the materials, structural designs, manufacturing, and skin attachment processes of e-tattoos. We classify e-tattoo functionalities into electrical, mechanical, optical, thermal, and chemical sensing, as well as wound healing and other treatments. After discussing energy harvesting and storage capabilities, we outline strategies for the system integration of wireless e-tattoos. In the end, we offer personal perspectives on the remaining challenges and future opportunities in the field.
Collapse
Affiliation(s)
- Hongbian Li
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Philip Tan
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Yifan Rao
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Sarnab Bhattacharya
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Zheliang Wang
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Sangjun Kim
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Susmita Gangopadhyay
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Hongyang Shi
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Matija Jankovic
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Heeyong Huh
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Zhengjie Li
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Pukar Maharjan
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Jonathan Wells
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Hyoyoung Jeong
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, United States
| | - Yaoyao Jia
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Nanshu Lu
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
- Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
5
|
Lee H, Park S, Kwon H, Cho B, Park JH, Lee HY. Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device. Korean Circ J 2024; 54:93-104. [PMID: 38196118 PMCID: PMC10864248 DOI: 10.4070/kcj.2023.0303] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/03/2023] [Accepted: 12/12/2023] [Indexed: 01/11/2024] Open
Abstract
BACKGROUNDS AND OBJECTIVES This study aimed to evaluate the applicability and precision of a ring-type cuffless blood pressure (BP) measurement device, CART-I Plus, compared to conventional 24-hour ambulatory BP monitoring (ABPM). METHODS Forty patients were recruited, and 33 participants were included in the final analysis. Each participant wore both CART-I Plus and ABPM devices on the same arm for approximately 24 hours. BP estimation from CART-I Plus, derived from photoplethysmography (PPG) signals, were compared with the corresponding ABPM measurements. RESULTS The CART-I Plus recorded systolic blood pressure (SBP)/diastolic blood pressure (DBP) values of 131.4±14.1/81.1±12.0, 132.7±13.9/81.9±11.9, and 128.7±14.6/79.3±12.2 mmHg for 24-hour, daytime, and nighttime periods respectively, compared to ABPM values of 129.7±11.7/84.4±11.2, 131.9±11.6/86.3±11.1, and 124.5±13.6/80.0±12.2 mmHg. Mean differences in SBP/DBP between the two devices were 1.74±6.69/-3.24±6.51 mmHg, 0.75±7.44/-4.41±7.42 mmHg, and 4.15±6.15/-0.67±5.23 mmHg for 24-hour, daytime, and nighttime periods respectively. Strong correlations were also observed between the devices, with r=0.725 and r=0.750 for transitions in SBP and DBP from daytime to nighttime, respectively (both p<0.001). CONCLUSIONS The CART-I Plus device, with its unique ring-type design, shows promising accuracy in BP estimation and offers a potential avenue for continuous BP monitoring in clinical practice. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT06084065.
Collapse
Affiliation(s)
- Huijin Lee
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Sungjoon Park
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Hyuktae Kwon
- Department of Family Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Belong Cho
- Department of Family Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Jin Ho Park
- Department of Family Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Hae-Young Lee
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
| |
Collapse
|
6
|
Avoke D, Elshafeey A, Weinstein R, Kim CH, Martin SS. Digital Health in Diabetes and Cardiovascular Disease. Endocr Res 2024; 49:124-136. [PMID: 38605594 DOI: 10.1080/07435800.2024.2341146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 04/04/2024] [Indexed: 04/13/2024]
Abstract
BACKGROUND Digital health technologies are rapidly evolving and transforming the care of diabetes and cardiovascular disease (CVD). PURPOSE OF THE REVIEW In this review, we discuss emerging approaches incorporating digital health technologies to improve patient outcomes through a more continuous, accessible, proactive, and patient-centered approach. We discuss various mechanisms of potential benefit ranging from early detection to enhanced physiologic monitoring over time to helping shape important management decisions and engaging patients in their care. Furthermore, we discuss the potential for better individualization of management, which is particularly important in diseases with heterogeneous and complex manifestations, such as diabetes and cardiovascular disease. This narrative review explores ways to leverage digital health technology to better extend the reach of clinicians beyond the physical hospital and clinic spaces to address disparities in the diagnosis, treatment, and prevention of diabetes and cardiovascular disease. CONCLUSION We are at the early stages of the shift to digital medicine, which holds substantial promise not only to improve patient outcomes but also to lower the costs of care. The review concludes by recognizing the challenges and limitations that need to be addressed for optimal implementation and impact. We present recommendations on how to navigate these challenges as well as goals and opportunities in utilizing digital health technology in the management of diabetes and prevention of adverse cardiovascular outcomes.
Collapse
Affiliation(s)
- Dorothy Avoke
- Department of Medicine, Johns Hopkins Hospital, Baltimore, MD, USA
| | | | - Robert Weinstein
- Department of Medicine, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Chang H Kim
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Seth S Martin
- Department of Medicine, Johns Hopkins Hospital, Baltimore, MD, USA
- Department of Medicine, Johns Hopkins School of Medicine, Baltimore, MD, USA
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
7
|
Hou J, Nesaragi N, Tronstad C. Electrical bioimpedance in the era of artificial intelligence. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2024; 15:1-3. [PMID: 38304720 PMCID: PMC10830329 DOI: 10.2478/joeb-2024-0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Indexed: 02/03/2024]
Affiliation(s)
- Jie Hou
- Department of Physics, University of Oslo, 0316Oslo, Norway
| | | | - Christian Tronstad
- Department of Clinical and Biomedical Engineering, Oslo University Hospital, 0372Oslo, Norway
| |
Collapse
|
8
|
Baker S, Yogavijayan T, Kandasamy Y. Towards Non-Invasive and Continuous Blood Pressure Monitoring in Neonatal Intensive Care Using Artificial Intelligence: A Narrative Review. Healthcare (Basel) 2023; 11:3107. [PMID: 38131997 PMCID: PMC10743031 DOI: 10.3390/healthcare11243107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 11/29/2023] [Accepted: 12/04/2023] [Indexed: 12/23/2023] Open
Abstract
Preterm birth is a live birth that occurs before 37 completed weeks of pregnancy. Approximately 11% of babies are born preterm annually worldwide. Blood pressure (BP) monitoring is essential for managing the haemodynamic stability of preterm infants and impacts outcomes. However, current methods have many limitations associated, including invasive measurement, inaccuracies, and infection risk. In this narrative review, we find that artificial intelligence (AI) is a promising tool for the continuous measurement of BP in a neonatal cohort, based on data obtained from non-invasive sensors. Our findings highlight key sensing technologies, AI techniques, and model assessment metrics for BP sensing in the neonatal cohort. Moreover, our findings show that non-invasive BP monitoring leveraging AI has shown promise in adult cohorts but has not been broadly explored for neonatal cohorts. We conclude that there is a significant research opportunity in developing an innovative approach to provide a non-invasive alternative to existing continuous BP monitoring methods, which has the potential to improve outcomes for premature babies.
Collapse
Affiliation(s)
- Stephanie Baker
- College of Science and Engineering, James Cook University, Cairns, QLD 4878, Australia
| | - Thiviya Yogavijayan
- College of Medicine and Dentistry, James Cook University, Townsville, QLD 4811, Australia;
| | - Yogavijayan Kandasamy
- Department of Neonatology, Townsville University Hospital, Townsville, QLD 4811, Australia;
| |
Collapse
|
9
|
Yu Y, Lowe A, Anand G, Kalra A, Zhang H. The Investigation of Bio-impedance Analysis at a Wrist Phantom with Two Pulsatile Arteries. Cardiovasc Eng Technol 2023; 14:810-826. [PMID: 37848736 DOI: 10.1007/s13239-023-00689-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 09/26/2023] [Indexed: 10/19/2023]
Abstract
PURPOSE Bio-impedance analysis (BIA) has been widely investigated for hemodynamic monitoring. However, previous works rarely modelled two synchronously pulsatile arteries (representing the radial and ulnar arteries) in the wrist/forearm model. This work aims to clarify and quantify the influences of two pulsatile arteries on BIA. METHODS First, two blood-filled arteries were structured in a 3D wrist segment using the finite element method (FEM). Afterwards, an easy-to-produce two-arteries artificial wrist was fabricated with two components: gelatine-based surrounding tissue phantom and saline blood phantom. A syringe driver was utilised to constrict the arteries, and the impedance signals were measured using a Multi-frequency Impedance Analyser (MFIA). RESULTS Both simulation and experimental results demonstrated the non-negligible influences of the ulnar artery on the overall BIA, inducing unwanted resistance changes to the acquired signals from the radial artery. The phantom experiments revealed the summation of the individual resistance changes caused by a single pulsatile artery was approximately equal to the measured resistance change caused by two synchronously pulsatile arteries, confirming the measured impedance signal at the wrist contains the pulsatile information from both arteries. CONCLUSION This work is the first simulation and phantom investigation into two synchronously pulsatile arteries under BIA in the distal forearm, providing a better insight and understanding in the morphology of measured impedance signals. Future research can accordingly select either a small spacing 4-spot electrode configuration for a single artery sensing or a band electrode configuration for overall pulsatile arteries sensing. A more accurate estimation of blood volume change and pulse wave analysis (PWA) could help to develop cuffless blood pressure measurement (BPM).
Collapse
Affiliation(s)
- Yang Yu
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, 1010, New Zealand.
| | - Andrew Lowe
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, 1010, New Zealand
| | - Gautam Anand
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, 1010, New Zealand
| | - Anubha Kalra
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, 1010, New Zealand
| | - Huiyang Zhang
- Institute of Biomedical Technologies, Auckland University of Technology, Auckland, 1010, New Zealand
| |
Collapse
|
10
|
Mohammed H, Chen HB, Li Y, Sabor N, Wang JG, Wang G. Meta-Analysis of Pulse Transition Features in Non-Invasive Blood Pressure Estimation Systems: Bridging Physiology and Engineering Perspectives. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:1257-1281. [PMID: 38015673 DOI: 10.1109/tbcas.2023.3334960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
The pulse transition features (PTFs), including pulse arrival time (PAT) and pulse transition time (PTT), hold significant importance in estimating non-invasive blood pressure (NIBP). However, the literature showcases considerable variations in terms of PTFs' correlation with blood pressure (BP), accuracy in NIBP estimation, and the comprehension of the relationship between PTFs and BP. This inconsistency is exemplified by the wide-ranging correlations reported across studies investigating the same feature. Furthermore, investigations comparing PAT and PTT have yielded conflicting outcomes. Additionally, PTFs have been derived from various bio-signals, capturing distinct characteristic points like the pulse's foot and peak. To address these inconsistencies, this study meticulously reviews a selection of such research endeavors while aligning them with the biological intricacies of blood pressure and the human cardiovascular system (CVS). Each study underwent evaluation, considering the specific signal acquisition locale and the corresponding recording procedure. Moreover, a comprehensive meta-analysis was conducted, yielding multiple conclusions that could significantly enhance the design and accuracy of NIBP systems. Grounded in these dual aspects, the study systematically examines PTFs in correlation with the specific study conditions and the underlying factors influencing the CVS. This approach serves as a valuable resource for researchers aiming to optimize the design of BP recording experiments, bio-signal acquisition systems, and the fine-tuning of feature engineering methodologies, ultimately advancing PTF-based NIBP estimation.
Collapse
|
11
|
Chowdhury AH, Jafarizadeh B, Baboukani AR, Pala N, Wang C. Monitoring and analysis of cardiovascular pulse waveforms using flexible capacitive and piezoresistive pressure sensors and machine learning perspective. Biosens Bioelectron 2023; 237:115449. [PMID: 37356409 DOI: 10.1016/j.bios.2023.115449] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 05/07/2023] [Accepted: 06/03/2023] [Indexed: 06/27/2023]
Abstract
The growing interest in flexible electronics for physiological monitoring, particularly using flexible pressure sensors for cardiovascular pulse waveforms monitoring, has potential applications in cuffless blood pressure measurement and early diagnosis of cardiovascular disease. High sensitivity, fast response time, good pressure resolution and a high signal-to-noise ratio are essential for effective pulse waveform detection. This review focuses on flexible capacitive and piezoresistive pressure sensors, which have seen significant enhancements due to their simple operation, superior performance, wide range of materials, and easy fabrication. The comparison of sensing methods for acquiring pulse waveforms from the wrist artery, device integration configurations, high-quality pulse waveforms collection, and performance analysis of capacitive and piezoresistive sensors are discussed. The review also covers the use of machine learning for analyzing pulse waveforms for cardiovascular disease diagnosis and cuff-less blood pressure monitoring. Lastly, it provides perspectives on current challenges and further advancements in the field.
Collapse
Affiliation(s)
- Azmal Huda Chowdhury
- Department of Mechanical and Materials Engineering, Florida International University, Miami, FL, 33174, USA
| | - Borzooye Jafarizadeh
- Department of Mechanical and Materials Engineering, Florida International University, Miami, FL, 33174, USA
| | - Amin Rabiei Baboukani
- Department of Mechanical and Materials Engineering, Florida International University, Miami, FL, 33174, USA
| | - Nezih Pala
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL, 33174, USA
| | - Chunlei Wang
- Department of Mechanical and Materials Engineering, Florida International University, Miami, FL, 33174, USA.
| |
Collapse
|
12
|
Nowroozilarki Z, Mortazavi BJ, Jafari R. Variational Autoencoders for Biomedical Signal Morphology Clustering and Noise Detection. IEEE J Biomed Health Inform 2023; PP:10.1109/JBHI.2023.3320585. [PMID: 37768790 PMCID: PMC10984704 DOI: 10.1109/jbhi.2023.3320585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/30/2023]
Abstract
Accurate estimation of physiological biomarkers using raw waveform data from non-invasive wearable devices requires extensive data preprocessing. An automatic noise detection method in time-series data would offer significant utility for various domains. As data labeling is onerous, having a minimally supervised abnormality detection method for input data, as well as an estimation of the severity of the signal corruptness, is essential. We propose a model-free, time-series biomedical waveform noise detection framework using a Variational Autoencoder coupled with Gaussian Mixture Models, which can detect a range of waveform abnormalities without annotation, providing a confidence metric for each segment. Our technique operates on biomedical signals that exhibit periodicity of heart activities. This framework can be applied to any machine learning or deep learning model as an initial signal validator component. Moreover, the confidence score generated by the proposed framework can be incorporated into different models' optimization to construct confidence-aware modeling. We conduct experiments using dynamic time warping (DTW) distance of segments to validated cardiac cycle morphology. The result confirms that our approach removes noisy cardiac cycles and the remaining signals, classified as clean, exhibit a 59.92% reduction in the standard deviation of DTW distances. Using a dataset of bio-impedance data of 97885 cardiac cycles, we further demonstrate a significant improvement in the downstream task of cuffless blood pressure estimation, with an average reduction of 2.67 mmHg root mean square error (RMSE) of Diastolic Blood pressure and 2.13 mmHg RMSE of systolic blood pressure, with increases of average Pearson correlation of 0.28 and 0.08, with a statistically significant improvement of signal-to-noise ratio respectively in the presence of different synthetic noise sources. This enables burden-free validation of wearable sensor data for downstream biomedical applications.
Collapse
|
13
|
Yoon YH, Kim J, Lee KJ, Cho D, Oh JK, Kim M, Roh JH, Park HW, Lee JH. Blood Pressure Measurement Based on the Camera and Inertial Measurement Unit of a Smartphone: Instrument Validation Study. JMIR Mhealth Uhealth 2023; 11:e44147. [PMID: 37694382 PMCID: PMC10503482 DOI: 10.2196/44147] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 04/13/2023] [Accepted: 07/21/2023] [Indexed: 09/12/2023] Open
Abstract
Background Even though several mobile apps that can measure blood pressure have been developed, the data about the accuracy of these apps are limited. Objective We assessed the accuracy of AlwaysBP (test) in blood pressure measurement compared with the standard, cuff-based, manual method of brachial blood pressure measurement (reference). Methods AlwaysBP is a smartphone software that estimates systolic blood pressure (SBP) and diastolic blood pressure (DBP) based on pulse transit time (PTT). PTT was calculated with a finger photoplethysmogram and seismocardiogram using, respectively, the camera and inertial measurement unit sensor of a commercially available smartphone. After calculating PTT, SBP and DBP were estimated via the Bramwell-Hill and Moens-Korteweg equations. A calibration process was carried out 3 times for each participant to determine the input parameters of the equations. This study was conducted from March to August 2021 at Chungnam National University Sejong Hospital with 87 participants aged between 19 and 70 years who met specific conditions. The primary analysis aimed to evaluate the accuracy of the test method compared with the reference method for the entire study population. The secondary analysis was performed to confirm the stability of the test method for up to 4 weeks in 15 participants. At enrollment, gender, arm circumference, and blood pressure distribution were considered according to current guidelines. Results Among the 87 study participants, 45 (52%) individuals were male, and the average age was 35.6 (SD 10.4) years. Hypertension was diagnosed in 14 (16%) participants before this study. The mean test and reference SBPs were 120.0 (SD 18.8) and 118.7 (SD 20.2) mm Hg, respectively (difference: mean 1.2, SD 7.1 mm Hg). The absolute differences between the test and reference SBPs were <5, <10, and <15 mm Hg in 57.5% (150/261), 84.3% (220/261 ), and 94.6% (247/261) of measurements. The mean test and reference DBPs were 80.1 (SD 12.6) and 81.1 (SD 14.4) mm Hg, respectively (difference: mean -1.0, SD 6.0 mm Hg). The absolute differences between the test and reference DBPs were <5, <10, and <15 mm Hg in 75.5% (197/261), 93.9% (245/261), and 97.3% (254/261) of measurements, respectively. The secondary analysis showed that after 4 weeks, the differences between SBP and DBP were 0.1 (SD 8.8) and -2.4 (SD 7.6) mm Hg, respectively. Conclusions AlwaysBP exhibited acceptable accuracy in SBP and DBP measurement compared with the standard measurement method, according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization protocol criteria. However, further validation studies with a specific validation protocol designed for cuffless blood pressure measuring devices are required to assess clinical accuracy. This technology can be easily applied in everyday life and may improve the general population's awareness of hypertension, thus helping to control it.
Collapse
Affiliation(s)
- Yong-Hoon Yoon
- Chungnam National University Sejong Hospital, Sejong-Si, Republic of Korea
| | - Jongin Kim
- Deepmedi Research Institute of Technology, Seoul, Republic of Korea
| | - Kwang Jin Lee
- Deepmedi Research Institute of Technology, Seoul, Republic of Korea
| | - Dongrae Cho
- Deepmedi Research Institute of Technology, Seoul, Republic of Korea
| | - Jin Kyung Oh
- Chungnam National University Sejong Hospital, Sejong-Si, Republic of Korea
| | - Minsu Kim
- Chungnam National University Sejong Hospital, Sejong-Si, Republic of Korea
| | - Jae-Hyung Roh
- Chungnam National University Sejong Hospital, Sejong-Si, Republic of Korea
| | - Hyun Woong Park
- Chungnam National University Sejong Hospital, Sejong-Si, Republic of Korea
| | - Jae-Hwan Lee
- Chungnam National University Sejong Hospital, Sejong-Si, Republic of Korea
| |
Collapse
|
14
|
Li J, Jia H, Zhou J, Huang X, Xu L, Jia S, Gao Z, Yao K, Li D, Zhang B, Liu Y, Huang Y, Hu Y, Zhao G, Xu Z, Li J, Yiu CK, Gao Y, Wu M, Jiao Y, Zhang Q, Tai X, Chan RH, Zhang Y, Ma X, Yu X. Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure. Nat Commun 2023; 14:5009. [PMID: 37591881 PMCID: PMC10435523 DOI: 10.1038/s41467-023-40763-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 08/07/2023] [Indexed: 08/19/2023] Open
Abstract
Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial for preventing and diagnosing hypertension related diseases. However, current continuous BP monitoring instruments suffer from either bulky systems or poor user-device interfacial performance, hampering their applications in continuous BP monitoring. Here, we report a thin, soft, miniaturized system (TSMS) that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method, to allow real wearable, continuous wireless monitoring of ambulatory artery BP. By optimizing the materials selection, control/sampling strategy, and system integration, the TSMS exhibits improved interfacial performance while maintaining Grade A level measurement accuracy. Initial trials on 87 volunteers and clinical tracking of two hypertension individuals prove the capability of the TSMS as a reliable BP measurement product, and its feasibility and practical usability in precise BP control and personalized diagnosis schemes development.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Huiling Jia
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Jingkun Zhou
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Xingcan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Long Xu
- School of Mechanical and Aerospace Engineering, Jilin University, 130012, Changchun, China
| | - Shengxin Jia
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Zhan Gao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Kuanming Yao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Dengfeng Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Binbin Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yiming Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Ya Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yue Hu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Guangyao Zhao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zitong Xu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Jiyu Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuyu Gao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Mengge Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), 610054, Chengdu, China
| | - Yanli Jiao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qiang Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xuecheng Tai
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- Department of Mathematics, Hong Kong Baptist University, Hong Kong, China
| | - Raymond H Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuanting Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Xiaohui Ma
- Department of vascular and endovascular surgery, The first medical center of Chinese PLA General Hospital, 100853, Beijing, China.
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.
- City University of Hong Kong Shenzhen Research Institute, 518057, Shenzhen, China.
| |
Collapse
|
15
|
Metshein M, Abdullayev A, Gautier A, Larras B, Frappe A, Cardiff B, Annus P, Land R, Märtens O. Sensor-Location-Specific Joint Acquisition of Peripheral Artery Bioimpedance and Photoplethysmogram for Wearable Applications. SENSORS (BASEL, SWITZERLAND) 2023; 23:7111. [PMID: 37631647 PMCID: PMC10457752 DOI: 10.3390/s23167111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 08/05/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023]
Abstract
BACKGROUND Cardiovascular diseases (CVDs), being the culprit for one-third of deaths globally, constitute a challenge for biomedical instrumentation development, especially for early disease detection. Pulsating arterial blood flow, providing access to cardiac-related parameters, involves the whole body. Unobtrusive and continuous acquisition of electrical bioimpedance (EBI) and photoplethysmography (PPG) constitute important techniques for monitoring the peripheral arteries, requiring novel approaches and clever means. METHODS In this work, five peripheral arteries were selected for EBI and PPG signal acquisition. The acquisition sites were evaluated based on the signal morphological parameters. A small-data-based deep learning model, which increases the data by dividing them into cardiac periods, was proposed to evaluate the continuity of the signals. RESULTS The highest sensitivity of EBI was gained for the carotid artery (0.86%), three times higher than that for the next best, the posterior tibial artery (0.27%). The excitation signal parameters affect the measured EBI, confirming the suitability of classical 100 kHz frequency (average probability of 52.35%). The continuity evaluation of the EBI signals confirmed the advantage of the carotid artery (59.4%), while the posterior tibial artery (49.26%) surpasses the radial artery (48.17%). The PPG signal, conversely, commends the location of the posterior tibial artery (97.87%). CONCLUSIONS The peripheral arteries are highly suitable for non-invasive EBI and PPG signal acquisition. The posterior tibial artery constitutes a candidate for the joint acquisition of EBI and PPG signals in sensor-fusion-based wearable devices-an important finding of this research.
Collapse
Affiliation(s)
- Margus Metshein
- Thomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, Estonia
| | - Anar Abdullayev
- Thomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, Estonia
| | - Antoine Gautier
- University Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France
| | - Benoit Larras
- University Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France
| | - Antoine Frappe
- University Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France
| | - Barry Cardiff
- School of Electrical and Electronic Engineering, University College Dublin, D04V1W8 Dublin, Ireland
| | - Paul Annus
- Thomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, Estonia
| | - Raul Land
- Thomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, Estonia
| | - Olev Märtens
- Thomas Johann Seebeck Department of Electronics, Tallinn University of Technology, Ehitajate Tee 5, 19086 Tallinn, Estonia
| |
Collapse
|
16
|
Manga S, Muthavarapu N, Redij R, Baraskar B, Kaur A, Gaddam S, Gopalakrishnan K, Shinde R, Rajagopal A, Samaddar P, Damani DN, Shivaram S, Dey S, Mitra D, Roy S, Kulkarni K, Arunachalam SP. Estimation of Physiologic Pressures: Invasive and Non-Invasive Techniques, AI Models, and Future Perspectives. SENSORS (BASEL, SWITZERLAND) 2023; 23:5744. [PMID: 37420919 DOI: 10.3390/s23125744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 05/25/2023] [Accepted: 06/12/2023] [Indexed: 07/09/2023]
Abstract
The measurement of physiologic pressure helps diagnose and prevent associated health complications. From typical conventional methods to more complicated modalities, such as the estimation of intracranial pressures, numerous invasive and noninvasive tools that provide us with insight into daily physiology and aid in understanding pathology are within our grasp. Currently, our standards for estimating vital pressures, including continuous BP measurements, pulmonary capillary wedge pressures, and hepatic portal gradients, involve the use of invasive modalities. As an emerging field in medical technology, artificial intelligence (AI) has been incorporated into analyzing and predicting patterns of physiologic pressures. AI has been used to construct models that have clinical applicability both in hospital settings and at-home settings for ease of use for patients. Studies applying AI to each of these compartmental pressures were searched and shortlisted for thorough assessment and review. There are several AI-based innovations in noninvasive blood pressure estimation based on imaging, auscultation, oscillometry and wearable technology employing biosignals. The purpose of this review is to provide an in-depth assessment of the involved physiologies, prevailing methodologies and emerging technologies incorporating AI in clinical practice for each type of compartmental pressure measurement. We also bring to the forefront AI-based noninvasive estimation techniques for physiologic pressure based on microwave systems that have promising potential for clinical practice.
Collapse
Affiliation(s)
- Sharanya Manga
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Neha Muthavarapu
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Renisha Redij
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Avneet Kaur
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Sunil Gaddam
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Keerthy Gopalakrishnan
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Rutuja Shinde
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Poulami Samaddar
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Devanshi N Damani
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Internal Medicine, Texas Tech University Health Science Center, El Paso, TX 79995, USA
| | - Suganti Shivaram
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA
| | - Shuvashis Dey
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58105, USA
| | - Dipankar Mitra
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Computer Science, University of Wisconsin-La Crosse, La Crosse, WI 54601, USA
| | - Sayan Roy
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Electrical Engineering and Computer Science, South Dakota Mines, Rapid City, SD 57701, USA
| | - Kanchan Kulkarni
- Centre de Recherche Cardio-Thoracique de Bordeaux, University of Bordeaux, INSERM, U1045, 33000 Bordeaux, France
- IHU Liryc, Heart Rhythm Disease Institute, Fondation Bordeaux Université, Bordeaux, 33600 Pessac, France
| | - Shivaram P Arunachalam
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
17
|
Nan X, Xu Z, Cao X, Hao J, Wang X, Duan Q, Wu G, Hu L, Zhao Y, Yang Z, Gao L. A Review of Epidermal Flexible Pressure Sensing Arrays. BIOSENSORS 2023; 13:656. [PMID: 37367021 DOI: 10.3390/bios13060656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/11/2023] [Accepted: 06/14/2023] [Indexed: 06/28/2023]
Abstract
In recent years, flexible pressure sensing arrays applied in medical monitoring, human-machine interaction, and the Internet of Things have received a lot of attention for their excellent performance. Epidermal sensing arrays can enable the sensing of physiological information, pressure, and other information such as haptics, providing new avenues for the development of wearable devices. This paper reviews the recent research progress on epidermal flexible pressure sensing arrays. Firstly, the fantastic performance materials currently used to prepare flexible pressure sensing arrays are outlined in terms of substrate layer, electrode layer, and sensitive layer. In addition, the general fabrication processes of the materials are summarized, including three-dimensional (3D) printing, screen printing, and laser engraving. Subsequently, the electrode layer structures and sensitive layer microstructures used to further improve the performance design of sensing arrays are discussed based on the limitations of the materials. Furthermore, we present recent advances in the application of fantastic-performance epidermal flexible pressure sensing arrays and their integration with back-end circuits. Finally, the potential challenges and development prospects of flexible pressure sensing arrays are discussed in a comprehensive manner.
Collapse
Affiliation(s)
- Xueli Nan
- School of Automation and Software Engineering, Shanxi University, Taiyuan 030006, China
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Zhikuan Xu
- School of Automation and Software Engineering, Shanxi University, Taiyuan 030006, China
| | - Xinxin Cao
- School of Automation and Software Engineering, Shanxi University, Taiyuan 030006, China
| | - Jinjin Hao
- School of Automation and Software Engineering, Shanxi University, Taiyuan 030006, China
| | - Xin Wang
- School of Automation and Software Engineering, Shanxi University, Taiyuan 030006, China
| | - Qikai Duan
- School of Automation and Software Engineering, Shanxi University, Taiyuan 030006, China
| | - Guirong Wu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Liangwei Hu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
| | - Yunlong Zhao
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
- Discipline of Intelligent Instrument and Equipment, Xiamen University, Xiamen 361102, China
| | - Zekun Yang
- Key Laboratory of Instrumentation Science and Dynamic Measurement Ministry of Education, North University of China, Taiyuan 030051, China
| | - Libo Gao
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361102, China
- Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen 361005, China
| |
Collapse
|
18
|
Sel K, Mohammadi A, Pettigrew RI, Jafari R. Physics-informed neural networks for modeling physiological time series for cuffless blood pressure estimation. NPJ Digit Med 2023; 6:110. [PMID: 37296218 DOI: 10.1038/s41746-023-00853-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 05/24/2023] [Indexed: 06/12/2023] Open
Abstract
The bold vision of AI-driven pervasive physiological monitoring, through the proliferation of off-the-shelf wearables that began a decade ago, has created immense opportunities to extract actionable information for precision medicine. These AI algorithms model input-output relationships of a system that, in many cases, exhibits complex nature and personalization requirements. A particular example is cuffless blood pressure estimation using wearable bioimpedance. However, these algorithms need training over significant amount of ground truth data. In the context of biomedical applications, collecting ground truth data, particularly at the personalized level is challenging, burdensome, and in some cases infeasible. Our objective is to establish physics-informed neural network (PINN) models for physiological time series data that would use minimal ground truth information to extract complex cardiovascular information. We achieve this by building Taylor's approximation for gradually changing known cardiovascular relationships between input and output (e.g., sensor measurements to blood pressure) and incorporating this approximation into our proposed neural network training. The effectiveness of the framework is demonstrated through a case study: continuous cuffless BP estimation from time series bioimpedance data. We show that by using PINNs over the state-of-the-art time series models tested on the same datasets, we retain high correlations (systolic: 0.90, diastolic: 0.89) and low error (systolic: 1.3 ± 7.6 mmHg, diastolic: 0.6 ± 6.4 mmHg) while reducing the amount of ground truth training data on average by a factor of 15. This could be helpful in developing future AI algorithms to help interpret pervasive physiologic data using minimal amount of training data.
Collapse
Affiliation(s)
- Kaan Sel
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
| | - Amirmohammad Mohammadi
- Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA
| | | | - Roozbeh Jafari
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
- Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA.
- School of Engineering Medicine, Texas A&M University, Houston, TX, USA.
| |
Collapse
|
19
|
Joung J, Jung CW, Lee HC, Chae MJ, Kim HS, Park J, Shin WY, Kim C, Lee M, Choi C. Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations. Sci Rep 2023; 13:8605. [PMID: 37244974 DOI: 10.1038/s41598-023-35492-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 05/18/2023] [Indexed: 05/29/2023] Open
Abstract
Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text], [Formula: see text], and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel 'standard deviation of subject-calibration centring (SDS)' metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services.
Collapse
Affiliation(s)
- Jingon Joung
- Department of Electrical and Electronics Engineering, Chung-Ang University, Seoul, 06974, South Korea.
| | - Chul-Woo Jung
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, 03080, South Korea
| | - Hyung-Chul Lee
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, 03080, South Korea
| | - Moon-Jung Chae
- Department of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea
| | - Hae-Sung Kim
- Department of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea
| | - Jonghun Park
- Department of Industrial Engineering, Seoul National University, Seoul, 08826, South Korea
| | - Won-Yong Shin
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, 03722, South Korea
- Pohang University of Science and Technology (POSTECH) (Artificial Intelligence), Pohang, 37673, South Korea
| | | | | | | |
Collapse
|
20
|
Liu T, Gou GY, Gao F, Yao P, Wu H, Guo Y, Yin M, Yang J, Wen T, Zhao M, Li T, Chen G, Sun J, Ma T, Cheng J, Qi Z, Chen J, Wang J, Han M, Fang Z, Gao Y, Liu C, Xue N. Multichannel Flexible Pulse Perception Array for Intelligent Disease Diagnosis System. ACS NANO 2023; 17:5673-5685. [PMID: 36716225 PMCID: PMC10062340 DOI: 10.1021/acsnano.2c11897] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Accepted: 01/23/2023] [Indexed: 05/25/2023]
Abstract
Pressure sensors with high sensitivity, a wide linear range, and a quick response time are critical for building an intelligent disease diagnosis system that directly detects and recognizes pulse signals for medical and health applications. However, conventional pressure sensors have limited sensitivity and nonideal response ranges. We proposed a multichannel flexible pulse perception array based on polyimide/multiwalled carbon nanotube-polydimethylsiloxane nanocomposite/polyimide (PI/MPN/PI) sandwich-structure pressure sensor that can be applied for remote disease diagnosis. Furthermore, we established a mechanical model at the molecular level and guided the preparation of MPN. At the structural level, we achieved high sensitivity (35.02 kPa-1) and a broad response range (0-18 kPa) based on a pyramid-like bilayer microstructure with different upper and lower surfaces. A 27-channel (3 × 9) high-density sensor array was integrated at the device level, which can extract the spatial and temporal distribution information on a pulse. Furthermore, two intelligent algorithms were developed for extracting six-dimensional pulse information and automatic pulse recognition (the recognition rate reaches 97.8%). The results indicate that intelligent disease diagnosis systems have great potential applications in wearable healthcare devices.
Collapse
Affiliation(s)
- Tiezhu Liu
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Guang-yang Gou
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Fupeng Gao
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Pan Yao
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Haoyu Wu
- State
Key Laboratory of Organic−Inorganic Composites, Beijing University of Chemical Technology, Beijing10029, China
| | - Yusen Guo
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Minghui Yin
- Department
of Materials and Manufacturing, Beijing
University of Technology, Beijing100124, China
| | - Jie Yang
- TCM
Data Center & Institute of Information on Traditional Chinese
Medicine, China Academy of Chinese Medical
Sciences (CAMS), Beijing100700, China
| | - Tiancai Wen
- TCM
Data Center & Institute of Information on Traditional Chinese
Medicine, China Academy of Chinese Medical
Sciences (CAMS), Beijing100700, China
| | - Ming Zhao
- Department
of Neurosurgery, the First Medical Center, Chinese PLA General Hospital, Beijing100853, China
| | - Tong Li
- School
of Modern Post (School of Automation), Beijing
University of Posts and Telecommunications, Beijing100876, China
| | - Gang Chen
- School
of Modern Post (School of Automation), Beijing
University of Posts and Telecommunications, Beijing100876, China
| | - Jianhai Sun
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Tianjun Ma
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Jianqun Cheng
- School
of Integrated Circuit, Quanzhou University
of Information Engineering, Quanzhou, Fujian362000, China
| | - Zhimei Qi
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Jiamin Chen
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Junbo Wang
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
| | - Mengdi Han
- Department
of Biomedical Engineering, College of Future Technology, Peking University, Beijing100091, China
| | - Zhen Fang
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
- Personalized
Management of Chronic Respiratory Disease, Chinese Academy of Medical Sciences, Beijing100190, China
| | - Yangyang Gao
- State
Key Laboratory of Organic−Inorganic Composites, Beijing University of Chemical Technology, Beijing10029, China
| | - Chunxiu Liu
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
- Personalized
Management of Chronic Respiratory Disease, Chinese Academy of Medical Sciences, Beijing100190, China
| | - Ning Xue
- School
of Electronic, Electrical, and Communication Engineering, University of Chinese Academy of Sciences (UCAS), Beijing100049, China
- State
Key Laboratory of Transducer Technology, Aerospace Information Research
Institute (AIR), Chinese Academy of Sciences, Beijing100190, China
- Personalized
Management of Chronic Respiratory Disease, Chinese Academy of Medical Sciences, Beijing100190, China
| |
Collapse
|
21
|
Nour M, Polat K, Şentürk Ü, Arıcan M. A Novel Cuffless Blood Pressure Prediction: Uncovering New Features and New Hybrid ML Models. Diagnostics (Basel) 2023; 13:diagnostics13071278. [PMID: 37046499 PMCID: PMC10093721 DOI: 10.3390/diagnostics13071278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/15/2023] [Accepted: 03/23/2023] [Indexed: 03/31/2023] Open
Abstract
This paper investigates new feature extraction and regression methods for predicting cuffless blood pressure from PPG signals. Cuffless blood pressure is a technology that measures blood pressure without needing a cuff. This technology can be used in various medical applications, including home health monitoring, clinical uses, and portable devices. The new feature extraction method involves extracting meaningful features (time and chaotic features) from the PPG signals in the prediction of systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. These extracted features are then used as inputs to regression models, which are used to predict cuffless blood pressure. The regression model performances were evaluated using root mean squared error (RMSE), R2, mean square error (MSE), and the mean absolute error (MAE). The obtained RMSE was 4.277 for systolic blood pressure (SBP) values using the Matérn 5/2 Gaussian process regression model. The obtained RMSE was 2.303 for diastolic blood pressure (DBP) values using the rational quadratic Gaussian process regression model. The results of this study have shown that the proposed feature extraction and regression models can predict cuffless blood pressure with reasonable accuracy. This study provides a novel approach for predicting cuffless blood pressure and can be used to develop more accurate models in the future.
Collapse
Affiliation(s)
- Majid Nour
- Department of Electrical and Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Kemal Polat
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Bolu Abant Izzet Baysal University, 14280 Bolu, Turkey
- Correspondence:
| | - Ümit Şentürk
- Department of Computer Engineering, Faculty of Engineering, Bolu Abant Izzet Baysal University, 14280 Bolu, Turkey
| | - Murat Arıcan
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Bolu Abant Izzet Baysal University, 14280 Bolu, Turkey
| |
Collapse
|
22
|
Wang CF, Wang TY, Kuo PH, Wang HL, Li SZ, Lin CM, Chan SC, Liu TY, Lo YC, Lin SH, Chen YY. Upper-Arm Photoplethysmographic Sensor with One-Time Calibration for Long-Term Blood Pressure Monitoring. BIOSENSORS 2023; 13:321. [PMID: 36979533 PMCID: PMC10046397 DOI: 10.3390/bios13030321] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/16/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
Wearable cuffless photoplethysmographic blood pressure monitors have garnered widespread attention in recent years; however, the long-term performance values of these devices are questionable. Most cuffless blood pressure monitors require initial baseline calibration and regular recalibrations with a cuffed blood pressure monitor to ensure accurate blood pressure estimation, and their estimation accuracy may vary over time if left uncalibrated. Therefore, this study assessed the accuracy and long-term performance of an upper-arm, cuffless photoplethysmographic blood pressure monitor according to the ISO 81060-2 standard. This device was based on a nonlinear machine-learning model architecture with a fine-tuning optimized method. The blood pressure measurement protocol followed a validation procedure according to the standard, with an additional four weekly blood pressure measurements over a 1-month period, to assess the long-term performance values of the upper-arm, cuffless photoplethysmographic blood pressure monitor. The results showed that the photoplethysmographic signals obtained from the upper arm had better qualities when compared with those measured from the wrist. When compared with the cuffed blood pressure monitor, the means ± standard deviations of the difference in BP at week 1 (baseline) were -1.36 ± 7.24 and -2.11 ± 5.71 mmHg for systolic and diastolic blood pressure, respectively, which met the first criterion of ≤5 ± ≤8.0 mmHg and met the second criterion of a systolic blood pressure ≤ 6.89 mmHg and a diastolic blood pressure ≤ 6.84 mmHg. The differences in the uncalibrated blood pressure values between the test and reference blood pressure monitors measured from week 2 to week 5 remained stable and met both criteria 1 and 2 of the ISO 81060-2 standard. The upper-arm, cuffless photoplethysmographic blood pressure monitor in this study generated high-quality photoplethysmographic signals with satisfactory accuracy at both initial calibration and 1-month follow-ups. This device could be a convenient and practical tool to continuously measure blood pressure over long periods of time.
Collapse
Affiliation(s)
- Ching-Fu Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- Biomedical Engineering Research and Development Center, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
| | - Ting-Yun Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- Material and Chemical Research Laboratories, Industrial Technology Research Institute, No. 195, Sec. 4, Chunghsing Rd., Hsinchu 310401, Taiwan
| | - Pei-Hsin Kuo
- Department of Neurology, Hualien Tzu Chi Hospital, Buddhist Tzu chi Medical Foundation, No. 707, Sec. 3, Zhongyang Rd., Hualien 970473, Taiwan
- Department of Neurology, School of Medicine, Tzu Chi University, Hualien 97004, Taiwan
| | - Han-Lin Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
| | - Shih-Zhang Li
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
| | - Chia-Ming Lin
- Microlife Corporation, 9F, No. 431, Ruiguang Rd., Taipei 114063, Taiwan
| | - Shih-Chieh Chan
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- Microlife Corporation, 9F, No. 431, Ruiguang Rd., Taipei 114063, Taiwan
| | - Tzu-Yu Liu
- Material and Chemical Research Laboratories, Industrial Technology Research Institute, No. 195, Sec. 4, Chunghsing Rd., Hsinchu 310401, Taiwan
| | - Yu-Chun Lo
- The Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, No. 250, Wu-Xing St., Taipei 11031, Taiwan
| | - Sheng-Huang Lin
- Department of Neurology, Hualien Tzu Chi Hospital, Buddhist Tzu chi Medical Foundation, No. 707, Sec. 3, Zhongyang Rd., Hualien 970473, Taiwan
- Department of Neurology, School of Medicine, Tzu Chi University, Hualien 97004, Taiwan
| | - You-Yin Chen
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- The Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, No. 250, Wu-Xing St., Taipei 11031, Taiwan
- Medical Device Innovation and Translation Center, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
| |
Collapse
|
23
|
Sel K, Mohammadi A, Pettigrew RI, Jafari R. Physics-Informed Neural Networks for Modeling Physiological Time Series: A Case Study with Continuous Blood Pressure. RESEARCH SQUARE 2023:rs.3.rs-2423200. [PMID: 36711741 PMCID: PMC9882661 DOI: 10.21203/rs.3.rs-2423200/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The bold vision of AI-driven pervasive physiological monitoring, through the proliferation of off-the-shelf wearables that began a decade ago, has created immense opportunities to extract actionable information for precision medicine. These AI algorithms model the input-output relationships of a system that, in many cases, exhibits complex nature and personalization requirements. A particular example is cuffless blood pressure estimation using wearable bioimpedance. However, these algorithms need to be trained with a significant amount of ground truth data. In the context of biomedical applications, collecting ground truth data, particularly at the personalized level is challenging, burdensome, and in some cases infeasible. Our objective is to establish physics-informed neural network (PINN) models for physiological time series data that would reduce reliance on ground truth information. We achieve this by building Taylor's approximation for the gradually changing known cardiovascular relationships between input and output (e.g., sensor measurements to blood pressure) and incorporating this approximation into our proposed neural network training. The effectiveness of the framework is demonstrated through a case study: continuous cuffless BP estimation from time series bioimpedance data. We show that by using PINNs over the state-of-the-art time series regression models tested on the same datasets, we retain a high correlation (systolic: 0.90, diastolic: 0.89) and low error (systolic: 1.3 ± 7.6 mmHg, diastolic: 0.6 ± 6.4 mmHg) while reducing the amount of ground truth training data on average by a factor of 15. This could be helpful in developing future AI algorithms to help interpret pervasive physiologic data using minimal amount of training data.
Collapse
Affiliation(s)
- Kaan Sel
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
| | - Amirmohammad Mohammadi
- Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA
| | | | - Roozbeh Jafari
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA,Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA,School of Engineering Medicine, Texas A&M University, Houston, TX, USA,Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA,corresponding author:
| |
Collapse
|
24
|
Showkat I, Khanday FA, Beigh MR. A review of bio-impedance devices. Med Biol Eng Comput 2023; 61:927-950. [PMID: 36637716 DOI: 10.1007/s11517-022-02763-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Accepted: 12/27/2022] [Indexed: 01/14/2023]
Abstract
Bio-impedance measurement analysis primarily refers to a safe and a non-invasive technique to analyze the electrical changes in living tissues on the application of low-value alternating current. It finds applications both in the biomedical and the agricultural fields. This paper concisely reviews the origin and measurement approaches for concepts and fundamentals of bio-impedance followed by a critical review on bio-impedance portable devices with main emphasis on the embedded system approach which is in demand due to its miniature size and present lifestyle preference of monitoring health in real time. The paper also provides a comprehensive review of various bio-impedance circuits with emphasis on the measurement and calibration techniques.
Collapse
Affiliation(s)
- Insha Showkat
- Department of Electronics and Instrumentation Technology, University of Kashmir, Hazratbal, Srinagar, Jammu and Kashmir, India
| | - Farooq A Khanday
- Department of Electronics and Instrumentation Technology, University of Kashmir, Hazratbal, Srinagar, Jammu and Kashmir, India.
| | - M Rafiq Beigh
- Department of Electronics, Govt. Degree College Sumbal, Sumbal, J&K, India
| |
Collapse
|
25
|
Fuadah YN, Lim KM. Classification of Blood Pressure Levels Based on Photoplethysmogram and Electrocardiogram Signals with a Concatenated Convolutional Neural Network. Diagnostics (Basel) 2022; 12:diagnostics12112886. [PMID: 36428946 PMCID: PMC9689744 DOI: 10.3390/diagnostics12112886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/04/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
Hypertension is a severe public health issue worldwide that significantly increases the risk of cardiac vascular disease, stroke, brain hemorrhage, and renal dysfunction. Early screening of blood pressure (BP) levels is essential to prevent the dangerous complication associated with hypertension as the leading cause of death. Recent studies have focused on employing photoplethysmograms (PPG) with machine learning to classify BP levels. However, several studies claimed that electrocardiograms (ECG) also strongly correlate with blood pressure. Therefore, we proposed a concatenated convolutional neural network which integrated the features extracted from PPG and ECG signals. This study used the MIMIC III dataset, which provided PPG, ECG, and arterial blood pressure (ABP) signals. A total of 14,298 signal segments were obtained from 221 patients, which were divided into 9150 signals of train data, 2288 signals of validation data, and 2860 signals of test data. In the training process, five-fold cross-validation was applied to select the best model with the highest classification performance. The proposed concatenated CNN architecture using PPG and ECG obtained the highest test accuracy of 94.56-95.15% with a 95% confidence interval in classifying BP levels into hypotension, normotension, prehypertension, hypertension stage 1, and hypertension stage 2. The result shows that the proposed method is a promising solution to categorize BP levels effectively, assisting medical personnel in making a clinical diagnosis.
Collapse
Affiliation(s)
- Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Correspondence:
| |
Collapse
|
26
|
Guo CY, Chang HC, Wang KJ, Hsieh TL. An Arterial Compliance Sensor for Cuffless Blood Pressure Estimation Based on Piezoelectric and Optical Signals. MICROMACHINES 2022; 13:1327. [PMID: 36014249 PMCID: PMC9413124 DOI: 10.3390/mi13081327] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/07/2022] [Accepted: 08/12/2022] [Indexed: 06/15/2023]
Abstract
OBJECTIVE Blood pressure (BP) data can influence therapeutic decisions for some patients, while non-invasive devices that continuously monitor BP can provide patients with a more comprehensive BP assessment. Therefore, this study proposes a multi-sensor-based small cuffless BP monitoring device that integrates a piezoelectric sensor array and an optical sensor, which can monitor the patient's physiological signals from the radial artery. METHOD Based on the Moens-Korteweg (MK) equation of the hemodynamic model, pulse wave velocity (PWV) can be correlated with arterial compliance and BP can be estimated. Therefore, the novel method proposed in this study involves using a piezoelectric sensor array to measure the PWV and an optical sensor to measure the photoplethysmography (PPG) intensity ratio (PIR) signal to estimate the participant's arterial parameters. The parameters measured by multiple sensors were combined to estimate BP based on the P-β model derived from the MK equation. RESULT We recruited 20 participants for the BP monitoring experiment to compare the performance of the BP estimation method with the regression model and the P-β model method with arterial compliance. We then compared the estimated BP with a reference device for validation. The results are presented as the error mean ± standard deviation (SD). Based on the regression model method, systolic blood pressure (SBP) was 0.32 ± 5.94, diastolic blood pressure (DBP) was 2.17 ± 6.22, and mean arterial pressure (MAP) was 1.55 ± 5.83. The results of the P-β model method were as follows: SBP was 0.75 ± 3.9, DBP was 1.1 ± 3.12, and MAP was 0.49 ± 2.82. CONCLUSION According to the results of our proposed small cuffless BP monitoring device, both methods of estimating BP conform to ANSI/AAMI/ISO 81060-2:20181_5.2.4.1.2 criterion 1 and 2, and using arterial parameters to calibrate the MK equation model can improve BP estimate accuracy. In the future, our proposed device can provide patients with a convenient and comfortable BP monitoring solution. Since the device is small, it can be used in a public place without attracting other people's attention, thereby effectively improving the patient's right to privacy, and increasing their willingness to use it.
Collapse
Affiliation(s)
- Cheng-Yan Guo
- Accurate Meditech Inc., New Taipei City 241406, Taiwan
| | | | - Kuan-Jen Wang
- Accurate Meditech Inc., New Taipei City 241406, Taiwan
| | - Tung-Li Hsieh
- Department of Electronic Engineering, National Kaohsiung University of Science and Technology, No. 415, Jiangong Rd., Sanmin Dist., Kaohsiung City 807618, Taiwan
| |
Collapse
|
27
|
Falter M, Scherrenberg M, Driesen K, Pieters Z, Kaihara T, Xu L, Caiani EG, Castiglioni P, Faini A, Parati G, Dendale P. Smartwatch-Based Blood Pressure Measurement Demonstrates Insufficient Accuracy. Front Cardiovasc Med 2022; 9:958212. [PMID: 35898281 PMCID: PMC9309348 DOI: 10.3389/fcvm.2022.958212] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 06/23/2022] [Indexed: 11/13/2022] Open
Abstract
Background Novel smartwatch-based cuffless blood pressure (BP) measuring devices are coming to market and receive FDA and CE labels. These devices are often insufficiently validated for clinical use. This study aims to investigate a recently CE-cleared smartwatch using cuffless BP measurement in a population with normotensive and hypertensive individuals scheduled for 24-h BP measurement. Methods Patients that were scheduled for 24-h ambulatory blood pressure monitoring (ABPM) were recruited and received an additional Samsung Galaxy Watch Active 2 smartwatch for simultaneous BP measurement on their opposite arm. After calibration, patients were asked to measure as much as possible in a 24-h period. Manual activation of the smartwatch is necessary to measure the BP. Accuracy was calculated using sensitivity, specificity, positive and negative predictive values and ROC curves. Bland-Altman method and Taffé methods were used for bias and precision assessment. BP variability was calculated using average real variability, standard deviation and coefficient of variation. Results Forty patients were included. Bland-Altman and Taffé methods demonstrated a proportional bias, in which low systolic BPs are overestimated, and high BPs are underestimated. Diastolic BPs were all overestimated, with increasing bias toward lower BPs. Sensitivity and specificity for detecting systolic and/or diastolic hypertension were 83 and 41%, respectively. ROC curves demonstrate an area under the curve (AUC) of 0.78 for systolic hypertension and of 0.93 for diastolic hypertension. BP variability was systematically higher in the ABPM measurements compared to the smartwatch measurements. Conclusion This study demonstrates that the BP measurements by the Samsung Galaxy Watch Active 2 show a systematic bias toward a calibration point, overestimating low BPs and underestimating high BPs, when investigated in both normotensive and hypertensive patients. Standards for traditional non-invasive sphygmomanometers are not met, but these standards are not fully applicable to cuffless devices, emphasizing the urgent need for new standards for cuffless devices. The smartwatch-based BP measurement is not yet ready for clinical usage. Future studies are needed to further validate wearable devices, and also to demonstrate new possibilities of non-invasive, high-frequency BP monitoring.
Collapse
Affiliation(s)
- Maarten Falter
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
- Heart Centre Hasselt, Jessa Hospital, Hasselt, Belgium
- Department of Cardiology, Faculty of Medicine, KU Leuven, Leuven, Belgium
| | - Martijn Scherrenberg
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
- Heart Centre Hasselt, Jessa Hospital, Hasselt, Belgium
- Faculty of Medicine and Health Sciences, Antwerp University, Antwerp, Belgium
| | - Karen Driesen
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
| | - Zoë Pieters
- Data Science Institute, Hasselt University, Hasselt, Belgium
| | - Toshiki Kaihara
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
- Heart Centre Hasselt, Jessa Hospital, Hasselt, Belgium
- Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan
| | - Linqi Xu
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
- Heart Centre Hasselt, Jessa Hospital, Hasselt, Belgium
- School of Nursing, Jilin University, Changchun, China
| | - Enrico Gianluca Caiani
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- Institute of Electronics, Computer and Telecommunication Engineering, Consiglio Nazionale delle Ricerche, Milan, Italy
| | | | - Andrea Faini
- Department of Cardiovascular Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, S. Luca Hospital, Milan, Italy
| | - Gianfranco Parati
- Department of Cardiovascular Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, S. Luca Hospital, Milan, Italy
- Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy
| | - Paul Dendale
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
- Heart Centre Hasselt, Jessa Hospital, Hasselt, Belgium
| |
Collapse
|
28
|
Yu Y, Anand G, Lowe A, Zhang H, Kalra A. Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis. SENSORS (BASEL, SWITZERLAND) 2022; 22:4736. [PMID: 35808233 PMCID: PMC9268936 DOI: 10.3390/s22134736] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 06/13/2022] [Accepted: 06/21/2022] [Indexed: 06/15/2023]
Abstract
This paper improves the accuracy of quantification in the arterial diameter-dependent impedance variance by altering the electrode configuration. The finite element analysis was implemented with a 3D human wrist fragment using ANSYS Electronics Desktop, containing fat, muscle, and a blood-filled radial artery. Then, the skin layer and bones were stepwise added, helping to understand the dielectric response of multi-tissues and blood flow from 1 kHz to 1 MHz, the current distribution throughout the wrist, and the optimisation of electrode configurations for arterial pulse sensing. Moreover, a low-cost wrist phantom was fabricated, containing two components: the surrounding tissue simulant (20 wt % gelatine power and 0.017 M sodium chloride (NaCl) solution) and the blood simulant (0.08 M NaCl solution). The blood-filled artery was constricted using a desktop injection pump, and the impedance change was measured by the Multi-frequency Impedance Analyser (MFIA). The simulation revealed the promising capabilities of band electrodes to generate a more uniform current distribution than the traditional spot electrodes. Both simulation and phantom experimental results indicated that a longer spacing between current-carrying (CC) electrodes with shorter spacing between pick-up (PU) electrodes in the middle could sense a more uniform electric field, engendering a more accurate arterial diameter estimation. This work provided an improved electrode configuration for more accurate arterial diameter estimation from the numerical simulation and tissue phantom perspectives.
Collapse
|
29
|
Phan DT, Nguyen CH, Nguyen TDP, Tran LH, Park S, Choi J, Lee BI, Oh J. A Flexible, Wearable, and Wireless Biosensor Patch with Internet of Medical Things Applications. BIOSENSORS 2022; 12:bios12030139. [PMID: 35323409 PMCID: PMC8945966 DOI: 10.3390/bios12030139] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 02/19/2022] [Accepted: 02/20/2022] [Indexed: 05/05/2023]
Abstract
Monitoring the vital signs and physiological responses of the human body in daily activities is particularly useful for the early diagnosis and prevention of cardiovascular diseases. Here, we proposed a wireless and flexible biosensor patch for continuous and longitudinal monitoring of different physiological signals, including body temperature, blood pressure (BP), and electrocardiography. Moreover, these modalities for tracking body movement and GPS locations for emergency rescue have been included in biosensor devices. We optimized the flexible patch design with high mechanical stretchability and compatibility that can provide reliable and long-term attachment to the curved skin surface. Regarding smart healthcare applications, this research presents an Internet of Things-connected healthcare platform consisting of a smartphone application, website service, database server, and mobile gateway. The IoT platform has the potential to reduce the demand for medical resources and enhance the quality of healthcare services. To further address the advances in non-invasive continuous BP monitoring, an optimized deep learning architecture with one-channel electrocardiogram signals is introduced. The performance of the BP estimation model was verified using an independent dataset; this experimental result satisfied the Association for the Advancement of Medical Instrumentation, and the British Hypertension Society standards for BP monitoring devices. The experimental results demonstrated the practical application of the wireless and flexible biosensor patch for continuous physiological signal monitoring with Internet of Medical Things-connected healthcare applications.
Collapse
Affiliation(s)
- Duc Tri Phan
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Cong Hoan Nguyen
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Thuy Dung Pham Nguyen
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Le Hai Tran
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Sumin Park
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Jaeyeop Choi
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Byeong-il Lee
- Department of Smart Healthcare, Pukyong National University, Busan 48513, Korea
- Correspondence: (B.-i.L.); (J.O.)
| | - Junghwan Oh
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
- Biomedical Engineering, Pukyong National University, Busan 48513, Korea
- Ohlabs Corporation, Busan 48513, Korea
- Correspondence: (B.-i.L.); (J.O.)
| |
Collapse
|