Zhang Y, Shankar SN, Vass WB, Lednicky JA, Fan ZH, Agdas D, Makuch R, Wu CY. Air Change Rate and SARS-CoV-2 Exposure in Hospitals and Residences: A Meta-Analysis. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2024; 58:217-243. [PMID: 38764553 PMCID: PMC11101186 DOI: 10.1080/02786826.2024.2312178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Accepted: 01/16/2024] [Indexed: 05/21/2024]
Abstract
As SARS-CoV-2 swept across the globe, increased ventilation and implementation of air cleaning were emphasized by the US CDC and WHO as important strategies to reduce the risk of inhalation exposure to the virus. To assess whether higher ventilation and air cleaning rates lead to lower exposure risk to SARS-CoV-2, 1274 manuscripts published between April 2020 and September 2022 were screened using key words "airborne SARS-CoV-2 or "SARS-CoV-2 aerosol". Ninety-three studies involved air sampling at locations with known sources (hospitals and residences) were selected and associated data were compiled. Two metrics were used to assess exposure risk: SARS-CoV-2 concentration and SARS-CoV-2 detection rate in air samples. Locations were categorized by type (hospital or residence) and proximity to the sampling location housing the isolated/quarantined patient (primary or secondary). The results showed that hospital wards had lower airborne virus concentrations than residential isolation rooms. A negative correlation was found between airborne virus concentrations in primary-occupancy areas and air changes per hour (ACH). In hospital settings, sample positivity rates were significantly reduced in secondary-occupancy areas compared to primary-occupancy areas, but they were similar across sampling locations in residential settings. ACH and sample positivity rates were negatively correlated, though the effect was diminished when ACH values exceeded 8. While limitations associated with diverse sampling protocols exist, data considered by this meta-analysis support the notion that higher ACH may reduce exposure risks to the virus in ambient air.
Collapse
Affiliation(s)
- Yuetong Zhang
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Mechanical Engineering, University of British Columbia, Vancouver, British Columnia, Canada
| | - Sripriya Nannu Shankar
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Environmental & Public Health Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - William B. Vass
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - John A. Lednicky
- Department of Environmental and Global Health, University of Florida, Gainesville, Florida, USA
- Emerging Pathogens Institute, University of Florida, Gainesville, Florida, USA
| | - Z. Hugh Fan
- Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida, USA
| | - Duzgun Agdas
- Engineering School of Sustainable Infrastructure & Environment, University of Florida, Gainesville, Florida, USA
| | - Robert Makuch
- Department of Biostatistics, Yale University School of Public Health, New Haven, Connecticut, USA
| | - Chang-Yu Wu
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Chemical, Environmental, and Materials Engineering, University of Miami, Coral Gables, Florida, USA
| |
Collapse
|
2
|
Chen K. Holistic understanding of ventilation rate in occupational health risk control. Ann N Y Acad Sci 2024; 1531:3-11. [PMID: 38050986 DOI: 10.1111/nyas.15087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Throughout the history of occupational health risk control, ventilation has been implemented widely as a tried-and-true method to reduce exposure intensity to airborne contaminants. Proper determination of the ventilation rate merits careful consideration when addressing concerns directed toward occupational health and indoor air quality in commercial buildings, albeit this does not translate well among the current engineering and scientific community. This article aims to facilitate a better understanding and proper determination of ventilation rates as a countermeasure for occupational health risk control. To that end, guidance is provided to select the appropriate ventilation rate for nonpandemic versus pandemic scenarios in terms of pertinent regulatory/professional codes and mathematical modeling tools. Limitations and assumptions of the models are summarized to facilitate proper application. Furthermore, the emerging DNA-based aerosol tracing technology, which helps to verify ventilation efficacy, is discussed.
Collapse
Affiliation(s)
- Kang Chen
- PetroChina Shanghai Advanced Materials Research Institute, Shanghai, China
- Capitol Technology University, Laurel, Maryland, USA
| |
Collapse
|
3
|
Hanna F, Alameddine I, Zaraket H, Alkalamouni H, El-Fadel M. Airborne influenza virus shedding by patients in health care units: Removal mechanisms affecting virus transmission. PLoS One 2023; 18:e0290124. [PMID: 37878553 PMCID: PMC10599543 DOI: 10.1371/journal.pone.0290124] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 08/01/2023] [Indexed: 10/27/2023] Open
Abstract
In this study, we characterize the distribution of airborne viruses (influenza A/B) in hospital rooms of patients with confirmed infections. Concurrently, we monitored fine particulate matter (PM2.5 & PM10) and several physical parameters including the room air exchange rate, temperature, and relative humidity to identify corresponding correlations with virus transport and removal determinants. The results continue to raise concerns about indoor air quality (IAQ) in healthcare facilities and the potential exposure of patients, staff and visitors to aerosolized viruses as well as elevated indoor PM levels caused by outdoor sources and/or re-suspension of settled particles by indoor activities. The influenza A virus was detected in 42% of 33 monitored rooms, with viruses detectible up to 1.5 m away from the infected patient. Active coughing was a statistically significant variable that contributed to a higher positive rate of virus detection in the collected air samples. Viral load across patient rooms ranged between 222 and 5,760 copies/m3, with a mean of 820 copies/m3. Measured PM2.5 and PM10 levels exceeded IAQ daily exposure guidelines in most monitored rooms. Statistical and numerical analyses showed that dispersion was the dominant viral removal pathway followed by settling. Changes in the relative humidity and the room's temperature were had a significant impact on the viral load removal. In closure, we highlight the need for an integrated approach to control determinants of IAQ in patients' rooms.
Collapse
Affiliation(s)
- Francis Hanna
- Department of Civil Infrastructure & Environmental Engineering, College of Engineering, Khalifa University, United Arab Emirates
- Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Lebanon
| | - Ibrahim Alameddine
- Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Lebanon
| | - Hassan Zaraket
- Department of Experimental Pathology, Immunology & Microbiology, Faculty of Medicine, American University of Beirut, Lebanon
| | - Habib Alkalamouni
- Department of Experimental Pathology, Immunology & Microbiology, Faculty of Medicine, American University of Beirut, Lebanon
| | - Mutasem El-Fadel
- Department of Civil Infrastructure & Environmental Engineering, College of Engineering, Khalifa University, United Arab Emirates
- Department of Civil & Environmental Engineering, Faculty of Engineering & Architecture, American University of Beirut, Lebanon
| |
Collapse
|
4
|
van der Feltz S, Schlünssen V, Basinas I, Begtrup LM, Burdorf A, Bonde JPE, Flachs EM, Peters S, Pronk A, Stokholm ZA, van Tongeren M, van Veldhoven K, Oude Hengel KM, Kolstad HA. Associations between an international COVID-19 job exposure matrix and SARS-CoV-2 infection among 2 million workers in Denmark. Scand J Work Environ Health 2023; 49:375-385. [PMID: 37167299 PMCID: PMC10790132 DOI: 10.5271/sjweh.4099] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Indexed: 05/13/2023] Open
Abstract
OBJECTIVES This study investigates the associations between the Danish version of a job exposure matrix for COVID-19 (COVID-19-JEM) and Danish register-based SARS-CoV-2 infection information across three waves of the pandemic. The COVID-19-JEM consists of four dimensions on transmission: two on mitigation measures, and two on precarious work characteristics. METHODS The study comprised 2 021 309 persons from the Danish working population between 26 February 2020 and 15 December 2021. Logistic regression models were applied to assess the associations between the JEM dimensions and overall score and SARS-CoV-2 infection across three infection waves, with peaks in March-April 2020, December-January 2021, and February-March 2022. Sex, age, household income, country of birth, wave, residential region and during wave 3 vaccination status were accounted for. RESULTS Higher risk scores within the transmission and mitigation dimensions and the overall JEM score resulted in higher odds ratios (OR) of a SARS-CoV-2 infection. OR attenuated across the three waves with ranges of 1.08-5.09 in wave 1, 1.06-1.60 in wave 2, and 1.05-1.45 in those not (fully) vaccinated in wave 3. In wave 3, no associations were found for those fully vaccinated. In all waves, the two precarious work dimensions showed weaker or inversed associations. CONCLUSIONS The COVID-19-JEM is a promising tool for assessing occupational exposure to SARS-CoV-2 and other airborne infectious agents that mainly spread between people who are in close contact with each other. However, its usefulness depends on applied restrictions and the vaccination status in the population of interest.
Collapse
Affiliation(s)
- Sophie van der Feltz
- Department of Occupational Medicine, Danish Ramazzini Center, Aarhus University Hospital, Palle Juul-Jensens Boulevard 35, 8200 Aarhus N, Denmark.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Saeedi R, Ahmadi E, Hassanvand MS, Mohasel MA, Yousefzadeh S, Safari M. Implemented indoor airborne transmission mitigation strategies during COVID-19: a systematic review. JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE & ENGINEERING 2023; 21:11-20. [PMID: 37152068 PMCID: PMC9968468 DOI: 10.1007/s40201-023-00847-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 01/02/2023] [Indexed: 05/09/2023]
Abstract
The COVID-19 pandemic has inflicted major economic and health burdens across the world. On the other hand, the potential airborne transmission of SARS-COV-2 via air can deeply undermine the effectiveness of countermeasures against spreading the disease. Therefore, there is an intense focus to look for ways to mitigate the COVID-19 spread within various indoor settings. This work systematically reviewed articles regarding airborne transmission of SARS-COV2 in various indoor settings since the onset of the pandemic. The systematic search was performed in Scopus, Web of Science, and PubMed databases and has returned 19 original articles carefully screened with regard to inclusion and exclusion criteria. The results showed that the facilities, such as dormitories and classrooms, received the most attention followed by office buildings, healthcare facilities, residential buildings, and other potential enclosed spaces such as a metro wagon. Besides, the majority of the studies were conducted experimentally while other studies were done using computer simulations. United States (n = 5), Spain (n = 4) and China (n = 3) were the top three countries based on the number of performed research. Ventilation rate was the most influential parameter in controlling the infection spread. CO2 was the primary reference for viral spread in the buildings. The use of natural ventilation or a combination of mechanical and natural ventilations was found to be highly effective in the studies. The current work helps in furthering research on effective interventions to improve indoor air quality and control the spread of COVID-19 and other respiratory diseases. Supplementary information The online version contains supplementary material available at 10.1007/s40201-023-00847-0.
Collapse
Affiliation(s)
- Reza Saeedi
- Workplace Health Promotion Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Health, Safety and Environment (HSE), School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Ehsan Ahmadi
- Department of Environmental Health Engineering, Faculty of Health, Kashan University of Medical Sciences, Kashan, Iran
| | - Mohammad Sadegh Hassanvand
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
| | - Mehrnoosh Abtahi Mohasel
- Workplace Health Promotion Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Environmental Health Engineering, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Samira Yousefzadeh
- Department of Environmental Health Engineering, Faculty of Health, Kashan University of Medical Sciences, Kashan, Iran
| | - Mohammad Safari
- Workplace Health Promotion Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Parhizkar H, Fretz M, Laguerre A, Stenson J, Corsi RL, Van Den Wymelenberg KG, Gall ET. A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2023; 33:339-346. [PMID: 36424424 PMCID: PMC9686220 DOI: 10.1038/s41370-022-00499-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 11/01/2022] [Accepted: 11/02/2022] [Indexed: 05/24/2023]
Abstract
BACKGROUND Several studies suggest that far-field transmission (>6 ft) explains a significant number of COVID-19 superspreading outbreaks. OBJECTIVE Therefore, quantifying the ratio of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks. METHODS In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 0.76 m (2.5 ft), 1.52 m (5 ft), 2.28 m (7.5 ft) from the participant, as well as in the exhaust plenum of the chamber. RESULTS We observed that 0.76 m (2.5 ft) trials had ~36-44% higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field exposure relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 0.76 m, 1.52 m, and 2.28 m were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively. SIGNIFICANCE This study suggests that for rooms with similar airflow parameters disease transmission risk is dominated by near-field exposures for shorter event durations (e.g., initial 20-25-minutes of event) whereas far-field exposures are critical throughout the entire event and are increasingly more important for longer event durations. IMPACT STATEMENT We offer a novel methodology for studying the fate and transport of airborne bioaerosols in indoor spaces using VOCs as unique proxies for bioaerosols. We provide evidence that real-time measurement of VOCs can be applied in settings with human subjects to estimate the concentration of bioaerosol at different distances from the emitter. We also improve upon the conventional assumption that a well-mixed room exhibits instantaneous and perfect mixing by addressing spatial distances and mixing over time. We quantitatively assessed the exposure levels to breath tracers at alternate distances and provided more insights into the changes on "near-field to far-field" ratios over time. This method can be used in future to estimate the benefits of alternate environmental conditions and occupant behaviors.
Collapse
Affiliation(s)
- Hooman Parhizkar
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, 97209, USA
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, 97403, USA
| | - Mark Fretz
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, 97209, USA
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, 97403, USA
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, 97403, USA
| | - Aurélie Laguerre
- Department of Mechanical and Materials Engineering, Portland State University, Portland, OR, 97201, USA
| | - Jason Stenson
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, 97209, USA
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, 97403, USA
| | - Richard L Corsi
- Department of Civil and Environmental Engineering, University of California, Davis, Davis, CA, 95616, USA
| | - Kevin G Van Den Wymelenberg
- Institute for Health and the Built Environment, University of Oregon, Portland, OR, 97209, USA.
- Energy Studies in Buildings Laboratory, University of Oregon, Eugene, OR, 97403, USA.
- Biology and the Built Environment Center, University of Oregon, Eugene, OR, 97403, USA.
| | - Elliott T Gall
- Department of Mechanical and Materials Engineering, Portland State University, Portland, OR, 97201, USA
| |
Collapse
|
7
|
Johnstone KF, Herzberg MC. Antimicrobial peptides: Defending the mucosal epithelial barrier. FRONTIERS IN ORAL HEALTH 2022; 3:958480. [PMID: 35979535 PMCID: PMC9376388 DOI: 10.3389/froh.2022.958480] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 06/30/2022] [Indexed: 11/13/2022] Open
Abstract
The recent epidemic caused by aerosolized SARS-CoV-2 virus illustrates the importance and vulnerability of the mucosal epithelial barrier against infection. Antimicrobial proteins and peptides (AMPs) are key to the epithelial barrier, providing immunity against microbes. In primitive life forms, AMPs protect the integument and the gut against pathogenic microbes. AMPs have also evolved in humans and other mammals to enhance newer, complex innate and adaptive immunity to favor the persistence of commensals over pathogenic microbes. The canonical AMPs are helictical peptides that form lethal pores in microbial membranes. In higher life forms, this type of AMP is exemplified by the defensin family of AMPs. In epithelial tissues, defensins, and calprotectin (complex of S100A8 and S100A9) have evolved to work cooperatively. The mechanisms of action differ. Unlike defensins, calprotectin sequesters essential trace metals from microbes, which inhibits growth. This review focuses on defensins and calprotectin as AMPs that appear to work cooperatively to fortify the epithelial barrier against infection. The antimicrobial spectrum is broad with overlap between the two AMPs. In mice, experimental models highlight the contribution of both AMPs to candidiasis as a fungal infection and periodontitis resulting from bacterial dysbiosis. These AMPs appear to contribute to innate immunity in humans, protecting the commensal microflora and restricting the emergence of pathobionts and pathogens. A striking example in human innate immunity is that elevated serum calprotectin protects against neonatal sepsis. Calprotectin is also remarkable because of functional differences when localized in epithelial and neutrophil cytoplasm or released into the extracellular environment. In the cytoplasm, calprotectin appears to protect against invasive pathogens. Extracellularly, calprotectin can engage pathogen-recognition receptors to activate innate immune and proinflammatory mechanisms. In inflamed epithelial and other tissue spaces, calprotectin, DNA, and histones are released from degranulated neutrophils to form insoluble antimicrobial barriers termed neutrophil extracellular traps. Hence, calprotectin and other AMPs use several strategies to provide microbial control and stimulate innate immunity.
Collapse
Affiliation(s)
| | - Mark C. Herzberg
- Department of Diagnostic and Biological Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN, United States
| |
Collapse
|