1
|
Wang D, Song J, Gao J, Qi J, Elson DS. Computational Polarization Imaging In Vivo through Surgical Smoke Using Refined Polarization Difference. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2309998. [PMID: 38837687 DOI: 10.1002/advs.202309998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 04/24/2024] [Indexed: 06/07/2024]
Abstract
In surgery, the surgical smoke generated during tissue dissection and hemostasis can degrade the image quality, affecting tissue visibility and interfering with the further image processing. Developing reliable and interpretable computational imaging methods for restoring smoke-affected surgical images is crucial, as typical image restoration methods relying on color-texture information are insufficient. Here a computational polarization imaging method through surgical smoke is demonstrated, including a refined polarization difference estimation based on the discrete electric field direction, and a corresponding prior-based estimation method, for better parameter estimation and image restoration performance. Results and analyses for ex vivo, the first in vivo animal experiments, and human oral cavity tests show that the proposed method achieves visibility restoration and color recovery of higher quality, and exhibits good generalization across diverse imaging scenarios with interpretability. The method is expected to enhance the precision, safety, and efficiency of advanced image-guided and robotic surgery.
Collapse
Affiliation(s)
- Daqian Wang
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou, 311121, China
- School of Computer and Information, Hefei University of Technology, Hefei, 230601, China
| | - Jiawei Song
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou, 311121, China
| | - Jun Gao
- School of Computer and Information, Hefei University of Technology, Hefei, 230601, China
| | - Ji Qi
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou, 311121, China
| | - Daniel S Elson
- Hamlyn Centre for Robotic Surgery, Imperial College London, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, London, SW7 2AZ, UK
| |
Collapse
|
2
|
Pham TTH, Ngoc Quach TN, Vo QHQ. Analysis of polarization features of human breast cancer tissue by Mueller matrix visualization. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:052917. [PMID: 38223746 PMCID: PMC10787228 DOI: 10.1117/1.jbo.29.5.052917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 12/03/2023] [Accepted: 12/20/2023] [Indexed: 01/16/2024]
Abstract
Significance Breast cancer ranks second in the world in terms of the number of women diagnosed. Effective methods for its early-stage detection are critical for facilitating timely intervention and lowering the mortality rate. Aim Polarimetry provides much useful information on the structural properties of breast cancer tissue samples and is a valuable diagnostic tool. The present study classifies human breast tissue samples as healthy or cancerous utilizing a surface-illuminated backscatter polarization imaging technique. Approach The viability of the proposed approach is demonstrated using 95 breast tissue samples, including 35 healthy samples, 20 benign cancer samples, 20 grade-2 malignant samples, and 20 grade-3 malignant samples. Results The observation results reveal that element m 23 in the Mueller matrix of the healthy samples has a deeper color and greater intensity than that in the breast cancer samples. Conversely, element m 32 shows a lighter color and reduced intensity. Finally, element m 44 has a darker color in the healthy samples than in the cancer samples. The analysis of variance test results and frequency distribution histograms confirm that elements m 23 , m 32 , and m 44 provide an effective means of detecting and classifying human breast tissue samples. Conclusions Overall, the results indicate that surface-illuminated backscatter polarization imaging has significant potential as an assistive tool for breast cancer diagnosis and classification.
Collapse
Affiliation(s)
- Thi-Thu-Hien Pham
- International University, School of Biomedical Engineering, Ho Chi Minh City, Vietnam
- Vietnam National University HCMC, Ho Chi Minh City, Vietnam
| | - Thao-Ngan Ngoc Quach
- International University, School of Biomedical Engineering, Ho Chi Minh City, Vietnam
- Vietnam National University HCMC, Ho Chi Minh City, Vietnam
| | - Quoc-Hoang-Quyen Vo
- International University, School of Biomedical Engineering, Ho Chi Minh City, Vietnam
- Vietnam National University HCMC, Ho Chi Minh City, Vietnam
| |
Collapse
|
3
|
Iannucci LE, Gruev V, Lake SP. Influence of signal-to-noise ratio on DoLP and AoP measurements during reflectance-mode division-of-focal plane Stokes polarimetry of biological tissues. BIOMEDICAL OPTICS EXPRESS 2024; 15:2798-2810. [PMID: 38855679 PMCID: PMC11161357 DOI: 10.1364/boe.514539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 03/15/2024] [Accepted: 03/16/2024] [Indexed: 06/11/2024]
Abstract
Stokes polarimeter based endoscopes are emerging as an area of technology where polarization imaging can greatly impact clinical care by improving diagnostic tools without the use of exogenous contrast. Image acquisition in minimally invasive surgical settings is often beset by inherently limited illumination. A comprehensive analysis of how signal-to-noise (SNR) propagates through Stokes polarimetric outcomes such as degree of linear polarization (DoLP) and angle of polarization (AoP) in low light is important for future interpretation of data acquired in low-light conditions. A previously developed theoretical model of quantitative polarized light imaging (QPLI) analysis described SNR as a function of both incident light intensity and DoLP. When polarized light interacts with biological tissues, the resultant DoLP of exiting light is dependent on the underlying tissue microstructure. Therefore, in this study we explore how low light impacts SNR of QPLI outcomes of DoLP and AoP differently in tissue phantoms of varying microstructures. Data are compared to theoretical solutions of SNR of DoLP and AoP. Tissues were additionally loaded to varying magnitudes of strain to investigate how variable SNR affects the ability to discern dynamic realignment in biological tissues. We observed a high degree of congruency between experimental and theoretical data, with SNR depending on both light intensity and DoLP. Additionally, we found that AoP may have a greater resilience to noise overall than DoLP and, as such, may be particularly useful in conditions where light is inherently limited.
Collapse
Affiliation(s)
- Leanne E. Iannucci
- Department of Biomedical Engineering, McKelvey School of Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Viktor Gruev
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Champaign, IL, USA
| | - Spencer P. Lake
- Department of Biomedical Engineering, McKelvey School of Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Department of Mechanical Engineering and Materials Science, McKelvey School of Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Department of Orthopaedic Surgery, School of Medicine, Washington University in St. Louis, St. Louis, MO, USA
| |
Collapse
|
4
|
Bonaventura J, Morara K, Carlson R, Comrie C, Twer A, Hutchinson E, Sawyer TW. Evaluating backscattering polarized light imaging microstructural mapping capabilities through neural tissue and analogous phantom imaging. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:052914. [PMID: 38077501 PMCID: PMC10704260 DOI: 10.1117/1.jbo.29.5.052914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 10/01/2023] [Accepted: 11/06/2023] [Indexed: 12/18/2023]
Abstract
Significance Knowledge of fiber microstructure and orientation in the brain is critical for many applications. Polarized light imaging (PLI) has been shown to have potential for better understanding neural fiber microstructure and directionality due to the anisotropy in myelin sheaths surrounding nerve fibers of the brain. Continuing to advance backscattering based PLI systems could provide a valuable avenue for in vivo neural imaging. Aim To assess the potential of backscattering PLI systems, the ability to resolve crossing fibers, and the sensitivity to fiber inclination and curvature are considered across different imaging wavelengths. Approach Investigation of these areas of relative uncertainty is undergone through imaging potential phantoms alongside analogous regions of interest in fixed ferret brain samples with a five-wavelength backscattering Mueller matrix polarimeter. Results Promising phantoms are discovered for which the retardance, diattenuation and depolarization mappings are derived from the Mueller matrix and studied to assess the sensitivity of this polarimeter configuration to fiber orientations and tissue structures. Conclusions Rich avenues for future study include further classifying this polarimeter's sensitivity to fiber inclination and fiber direction to accurately produce microstructural maps of neural tissue.
Collapse
Affiliation(s)
- Justina Bonaventura
- University of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States
| | - Kellys Morara
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - Rhea Carlson
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - Courtney Comrie
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - AnneLeigh Twer
- University of Arizona, Department of Molecular and Cellular Biology, Tucson, Arizona, United States
| | - Elizabeth Hutchinson
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| | - Travis W. Sawyer
- University of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States
- University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States
| |
Collapse
|
5
|
Chen Y, Chu J, Xin B, Qi J. Mechanical stability of polarization signatures in biological tissue characterization. BIOMEDICAL OPTICS EXPRESS 2024; 15:2652-2665. [PMID: 38633097 PMCID: PMC11019670 DOI: 10.1364/boe.518756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 03/19/2024] [Accepted: 03/19/2024] [Indexed: 04/19/2024]
Abstract
Mueller matrix imaging polarimetry (MMIP) is a promising technique for investigating structural abnormalities in pathological diagnosis. The characterization stability of polarization signatures, described by Mueller matrix parameters (MMPs), correlates with the mechanical state of the biological medium. In this study, we developed an MMIP system capable of applying quantitative forces to samples and measuring the resulting polarization signatures. Mechanical stretching experiments were conducted on a mimicking phantom and a tissue sample at different force scales. We analyzed the textural features and data distribution of MMP images and evaluated the force effect on the characterization of MMPs using the structural similarity index. The results demonstrate that changes in the mechanical microenvironment (CMM) can cause textural fluctuations in MMP images, interfering with the stability of polarization signatures. Specifically, parameters of anisotropic orientation, retardance, and optical rotation are the most sensitive to CMM, inducing a dramatic change in the overall image texture, while other parameters (e.g., polarization, diattenuation, and depolarization) exhibit locality in their response to CMM. For some MMPs, CMM can enhance regional textural contrasts. This study elucidates the mechanical stability of polarization signatures in biological tissue characterization and provides a valuable reference for further research toward minimizing CMM influence.
Collapse
Affiliation(s)
- Yongtai Chen
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou 311100, China
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China
| | - Jinkui Chu
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China
| | - Benda Xin
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, China
| | - Ji Qi
- Research Center for Frontier Fundamental Studies, Zhejiang Lab, Hangzhou 311100, China
| |
Collapse
|
6
|
Kim J, Song S, Kim H, Kim B, Park M, Oh SJ, Kim D, Cense B, Huh YM, Lee JY, Joo C. Ptychographic lens-less birefringence microscopy using a mask-modulated polarization image sensor. Sci Rep 2023; 13:19263. [PMID: 37935759 PMCID: PMC10630341 DOI: 10.1038/s41598-023-46496-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 11/01/2023] [Indexed: 11/09/2023] Open
Abstract
Birefringence, an inherent characteristic of optically anisotropic materials, is widely utilized in various imaging applications ranging from material characterizations to clinical diagnosis. Polarized light microscopy enables high-resolution, high-contrast imaging of optically anisotropic specimens, but it is associated with mechanical rotations of polarizer/analyzer and relatively complex optical designs. Here, we present a form of lens-less polarization-sensitive microscopy capable of complex and birefringence imaging of transparent objects without an optical lens and any moving parts. Our method exploits an optical mask-modulated polarization image sensor and single-input-state LED illumination design to obtain complex and birefringence images of the object via ptychographic phase retrieval. Using a camera with a pixel size of 3.45 μm, the method achieves birefringence imaging with a half-pitch resolution of 2.46 μm over a 59.74 mm2 field-of-view, which corresponds to a space-bandwidth product of 9.9 megapixels. We demonstrate the high-resolution, large-area, phase and birefringence imaging capability of our method by presenting the phase and birefringence images of various anisotropic objects, including a monosodium urate crystal, and excised mouse eye and heart tissues.
Collapse
Affiliation(s)
- Jeongsoo Kim
- Department of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Seungri Song
- Department of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Hongseong Kim
- Department of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Bora Kim
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Mirae Park
- Department of Radiology, College of Medicine, Yonsei University, Seoul, 03722, Republic of Korea
| | - Seung Jae Oh
- Department of Radiology, College of Medicine, Yonsei University, Seoul, 03722, Republic of Korea
- YUHS-KRIBB Medical Convergence Research Institute, Seoul, 03722, Republic of Korea
| | - Daesuk Kim
- Department of Mechanical System Engineering, Jeonbuk National University, Jeonju, 54896, Republic of Korea
| | - Barry Cense
- Department of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea
- Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA, 6009, Australia
| | - Yong-Min Huh
- Department of Radiology, College of Medicine, Yonsei University, Seoul, 03722, Republic of Korea
- YUHS-KRIBB Medical Convergence Research Institute, Seoul, 03722, Republic of Korea
- Department of Biochemistry and Molecular Biology, College of Medicine, Yonsei University, Seoul, 03722, Republic of Korea
| | - Joo Yong Lee
- Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Chulmin Joo
- Department of Mechanical Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
| |
Collapse
|
7
|
Schnelldorfer T, Gnanatheepam E, Trout R, Gado A, Pelletier JE, Dinh LT, Hunter M, Georgakoudi I. Evaluation of a polarization-enhanced laparoscopy prototype for improved intra-operative visualization of peritoneal metastases. Sci Rep 2023; 13:14892. [PMID: 37689765 PMCID: PMC10492843 DOI: 10.1038/s41598-023-41361-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 08/25/2023] [Indexed: 09/11/2023] Open
Abstract
Despite careful staging, the accuracy for preoperative detection of small distant metastases remains poor, creating a clinical need for enhanced operative staging to detect occult peritoneal metastases. This study evaluates a polarization-enhanced laparoscopy (PEL) prototype and assesses its potential for label-free contrast enhancement of peritoneal metastases. This is a first-in-human feasibility study, including 10 adult patients who underwent standard staging laparoscopy (SSL) for gastrointestinal malignancy along with PEL. Image frames of all detectable peritoneal lesions underwent analysis. Using Monte Carlo simulations, contrast enhancement based on the color dependence of PEL (mPEL) was assessed. The prototype performed safely, yet with limitations in illumination, fogging of the distal window, and image co-registration. Sixty-five lesions (56 presumed benign and 9 presumed malignant) from 3 patients represented the study sample. While most lesions were visible under human examination of both SSL and PEL videos, more lesions were apparent using SSL. However, this was likely due to reduced illumination under PEL. When controlling for such effects through direct comparisons of integrated (WLL) vs differential (PEL) polarization laparoscopy images, we found that PEL imaging yielded an over twofold Weber contrast enhancement over WLL. Further, enhancements in the discrimination between malignant and benign lesions were achieved by exploiting the PEL color contrast to enhance sensitivity to tissue scattering, influenced primarily by collagen. In conclusion, PEL appears safe and easy to integrate into the operating room. When controlling for the degree of illumination, image analysis suggested a potential for mPEL to provide improved visualization of metastases.
Collapse
Affiliation(s)
- Thomas Schnelldorfer
- Division of Surgical Oncology, Tufts Medical Center, 800 Washington St, Boston, MA, 02111, USA.
- Department of Translational Research, Lahey Hospital and Medical Center, 31 Mall Road, Burlington, MA, 01805, USA.
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA.
| | - Einstein Gnanatheepam
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA
| | - Robert Trout
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC, 27708, USA
| | - Ahmed Gado
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA
- Google LLC, San Francisco, CA, 94105-1673, USA
| | - Joyce-Ellen Pelletier
- Department of Translational Research, Lahey Hospital and Medical Center, 31 Mall Road, Burlington, MA, 01805, USA
| | - Long T Dinh
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA
| | - Martin Hunter
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA
- Department of Biomedical Engineering, S684 LSL, University of Massachusetts at Amherst, 240 Thatcher Road, Amherst, MA, 01003, USA
| | - Irene Georgakoudi
- Department of Biomedical Engineering, Tufts University, 200 College Avenue, Medford, MA, 02155, USA
- Genetics, Molecular and Cellular Biology Program, Graduate School of Biomedical Sciences, Tufts University, Boston, MA, 02111, USA
| |
Collapse
|
8
|
Qi J, Tatla T, Nissanka-Jayasuriya E, Yuan AY, Stoyanov D, Elson DS. Surgical polarimetric endoscopy for the detection of laryngeal cancer. Nat Biomed Eng 2023; 7:971-985. [PMID: 37012312 PMCID: PMC10427430 DOI: 10.1038/s41551-023-01018-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 02/23/2023] [Indexed: 04/05/2023]
Abstract
The standard-of-care for the detection of laryngeal pathologies involves distinguishing suspicious lesions from surrounding healthy tissue via contrasts in colour and texture captured by white-light endoscopy. However, the technique is insufficiently sensitive and thus leads to unsatisfactory rates of false negatives. Here we show that laryngeal lesions can be better detected in real time by taking advantage of differences in the light-polarization properties of cancer and healthy tissues. By measuring differences in polarized-light retardance and depolarization, the technique, which we named 'surgical polarimetric endoscopy' (SPE), generates about one-order-of-magnitude greater contrast than white-light endoscopy, and hence allows for the better discrimination of cancerous lesions, as we show with patients diagnosed with squamous cell carcinoma. Polarimetric imaging of excised and stained slices of laryngeal tissue indicated that changes in the retardance of polarized light can be largely attributed to architectural features of the tissue. We also assessed SPE to aid routine transoral laser surgery for the removal of a cancerous lesion, indicating that SPE can complement white-light endoscopy for the detection of laryngeal cancer.
Collapse
Affiliation(s)
- Ji Qi
- Research Center for Humanoid Sensing, Zhejiang Lab, Hangzhou, China.
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
- Department of Computer Science, University College London, London, UK.
- Centre For Medical Image Computing, University College London, London, UK.
- Hamlyn Centre for Robotic Surgery, Imperial College London, London, UK.
- Department of Surgery and Cancer, Imperial College London, London, UK.
| | - Taranjit Tatla
- Hamlyn Centre for Robotic Surgery, Imperial College London, London, UK
- Northwick Park Hospital, London North West University Healthcare NHS Trust, London, UK
| | | | - Alan Yilun Yuan
- Department of Electrical and Electronic Engineering, Imperial College London, London, UK
| | - Danail Stoyanov
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
- Department of Computer Science, University College London, London, UK.
- Centre For Medical Image Computing, University College London, London, UK.
| | - Daniel S Elson
- Hamlyn Centre for Robotic Surgery, Imperial College London, London, UK.
- Department of Surgery and Cancer, Imperial College London, London, UK.
| |
Collapse
|
9
|
Chen Y, Dong Y, Si L, Yang W, Du S, Tian X, Li C, Liao Q, Ma H. Dual Polarization Modality Fusion Network for Assisting Pathological Diagnosis. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:304-316. [PMID: 36155433 DOI: 10.1109/tmi.2022.3210113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Polarization imaging is sensitive to sub-wavelength microstructures of various cancer tissues, providing abundant optical characteristics and microstructure information of complex pathological specimens. However, how to reasonably utilize polarization information to strengthen pathological diagnosis ability remains a challenging issue. In order to take full advantage of pathological image information and polarization features of samples, we propose a dual polarization modality fusion network (DPMFNet), which consists of a multi-stream CNN structure and a switched attention fusion module for complementarily aggregating the features from different modality images. Our proposed switched attention mechanism could obtain the joint feature embeddings by switching the attention map of different modality images to improve their semantic relatedness. By including a dual-polarization contrastive training scheme, our method can synthesize and align the interaction and representation of two polarization features. Experimental evaluations on three cancer datasets show the superiority of our method in assisting pathological diagnosis, especially in small datasets and low imaging resolution cases. Grad-CAM visualizes the important regions of the pathological images and the polarization images, indicating that the two modalities play different roles and allow us to give insightful corresponding explanations and analysis on cancer diagnosis conducted by the DPMFNet. This technique has potential to facilitate the performance of pathological aided diagnosis and broaden the current digital pathology boundary based on pathological image features.
Collapse
|
10
|
Lee HR, Lotz C, Kai Groeber Becker F, Dembski S, Novikova T. Digital histology of tissue with Mueller microscopy and FastDBSCAN. APPLIED OPTICS 2022; 61:9616-9624. [PMID: 36606902 DOI: 10.1364/ao.473095] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 10/08/2022] [Indexed: 06/17/2023]
Abstract
We present the results of the automated post-processing of Mueller microscopy images of skin tissue models with a new fast version of the algorithm of density-based spatial clustering of applications with noise (FastDBSCAN) and discuss the advantages of its implementation for digital histology of tissue. We demonstrate that using the FastDBSCAN algorithm, one can produce the diagnostic segmentation of high resolution images of tissue by several orders of magnitude faster and with high accuracy (>97%) compared to the original version of the algorithm.
Collapse
|
11
|
Almanza-Ojeda DL, Rodriguez-Sotelo D, Castro-Sanchez R, Martinez-Celorio R, Ibarra-Manzano MA. Stokes Dynamic Polarimeter for Non-Organic and Organic Samples Characterization. SENSORS 2022; 22:s22062155. [PMID: 35336327 PMCID: PMC8952726 DOI: 10.3390/s22062155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/04/2022] [Accepted: 03/06/2022] [Indexed: 01/27/2023]
Abstract
The light polarization properties provide relevant information about linear–optical media quality and condition. The Stokes–Mueller formalism is commonly used to represent the polarization properties of the incident light over sample tests. Currently, different Stokes Polarimeters are mainly defined by resolution, acquisition rate, and light to carry out accurate and fast measurements. This work presents the implementation of an automatic Stokes dynamic polarimeter to characterize non-biological and biological material samples. The proposed system is configured to work in the He-Ne laser beam’s reflection or transmission mode to calculate the Mueller matrix. The instrumentation stage includes two asynchronous photoelastic modulators, two nano-stepper motors, and an acquisition data card at 2% of accuracy. The Mueller matrix is numerically calculated by software using the 36 measures method without requiring image processing. Experiments show the efficiency of the proposed optical array to calculate the Mueller matrix in reflection and transmission mode for different samples. The mean squared error is calculated for each element of the obtained matrix using referenced values of the air and a mirror. A comparison with similar works in the literature validates the proposed optical array.
Collapse
Affiliation(s)
- Dora-Luz Almanza-Ojeda
- Department of Electronics Engineering, Universidad de Guanajuato, Salamanca 36885, Mexico; (D.-L.A.-O.); (D.R.-S.); (M.-A.I.-M.)
| | - Daniela Rodriguez-Sotelo
- Department of Electronics Engineering, Universidad de Guanajuato, Salamanca 36885, Mexico; (D.-L.A.-O.); (D.R.-S.); (M.-A.I.-M.)
| | - Rogelio Castro-Sanchez
- Department of Electronics Engineering, Universidad de Guanajuato, Salamanca 36885, Mexico; (D.-L.A.-O.); (D.R.-S.); (M.-A.I.-M.)
- Correspondence: ; Tel.: +1-464-647-9940
| | | | - Mario-Alberto Ibarra-Manzano
- Department of Electronics Engineering, Universidad de Guanajuato, Salamanca 36885, Mexico; (D.-L.A.-O.); (D.R.-S.); (M.-A.I.-M.)
| |
Collapse
|
12
|
Probing Dynamic Variation of Layered Microstructure Using Backscattering Polarization Imaging. PHOTONICS 2022. [DOI: 10.3390/photonics9030153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Polarization imaging can quantitatively probe the microscopic structure of biological tissues which can be complex and consist of layered structures. In this paper, we established a fast-backscattering Mueller matrix imaging system to characterize the dynamic variation in the microstructure of single-layer and double-layer tissues as glycerin solution penetrated into the samples. The characteristic response of Mueller matrix elements, as well as polarization parameters with clearer physics meanings, show that polarization imaging can capture the dynamic variation in the layered microstructure. The experimental results are confirmed by Monte Carlo simulations. Further examination on the accuracy of Mueller matrix measurements also shows that much faster speed has to be considered when backscattering Mueller matrix imaging is applied to living samples.
Collapse
|
13
|
Trout RM, Gnanatheepam E, Gado A, Reik C, Ramella-Roman JC, Hunter M, Schnelldorfer T, Georgakoudi I. Polarization enhanced laparoscope for improved visualization of tissue structural changes associated with peritoneal cancer metastasis. BIOMEDICAL OPTICS EXPRESS 2022; 13:571-589. [PMID: 35284190 PMCID: PMC8884200 DOI: 10.1364/boe.443926] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 12/17/2021] [Accepted: 12/20/2021] [Indexed: 06/03/2023]
Abstract
A polarization enhanced laparoscopy (PEL) imaging system was developed to examine the feasibility of utilizing PEL to augment conventional white light laparoscopy (WLL) in the visualization of peritoneal cancer metastases. The system includes a modified tip to illuminate tissue with linearly polarized light and elements in the detection path enabling recording of corresponding images linearly co- and cross-polarized relative to the incident light. WLL and PEL images from optical tissue phantoms with features of distinct scattering cross-section confirm the enhanced sensitivity of PEL to such characteristics. Additional comparisons based on images acquired from collagen gels with different levels of fiber alignment highlight another source of PEL contrast. Finally, PEL and WLL images of ex vivo human tissue illustrate the potential of PEL to improve visualization of cancerous tissue surrounded by healthy peritoneum. Given the simplicity of the approach and its potential for seamless integration with current clinical practice, our results provide motivation for clinical translation.
Collapse
Affiliation(s)
- Robert M. Trout
- Department of Biomedical Engineering, Tufts University, 200 College Ave, Medford, MA 01255, USA
| | - Einstein Gnanatheepam
- Department of Biomedical Engineering, Tufts University, 200 College Ave, Medford, MA 01255, USA
| | - Ahmed Gado
- Department of Biomedical Engineering, Tufts University, 200 College Ave, Medford, MA 01255, USA
| | - Christopher Reik
- Department of Biomedical Engineering, Tufts University, 200 College Ave, Medford, MA 01255, USA
| | | | - Martin Hunter
- Department of Biomedical Engineering, University of Massachusetts at Amherst, Amherst, MA, USA
| | - Thomas Schnelldorfer
- Department of Biomedical Engineering, Tufts University, 200 College Ave, Medford, MA 01255, USA
- Division of Surgical Oncology, Tufts Medical Center, 800 Washington St, Boston, MA 02111, USA
- Contributed equally
| | - Irene Georgakoudi
- Department of Biomedical Engineering, Tufts University, 200 College Ave, Medford, MA 01255, USA
- Contributed equally
| |
Collapse
|
14
|
Louie DC, Tchvialeva L, Kalia S, Lui H, Lee TK. Polarization memory rate as a metric to differentiate benign and malignant tissues. BIOMEDICAL OPTICS EXPRESS 2022; 13:620-632. [PMID: 35284168 PMCID: PMC8884210 DOI: 10.1364/boe.446094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/15/2021] [Accepted: 12/21/2021] [Indexed: 06/14/2023]
Abstract
Non-invasive optical methods for cancer diagnostics, such as microscopy, spectroscopy, and polarimetry, are rapidly advancing. In this respect, finding new and powerful optical metrics is an indispensable task. Here we introduce polarization memory rate (PMR) as a sensitive metric for optical cancer diagnostics. PMR characterizes the preservation of circularly polarized light relative to linearly polarized light as light propagates in a medium. We hypothesize that because of well-known indicators associated with the morphological changes of cancer cells, like an enlarged nucleus size and higher chromatin density, PMR should be greater for cancerous than for the non-cancerous tissues. A thorough literature review reveals how this difference arises from the anomalous depolarization behaviour of many biological tissues. In physical terms, though most biological tissue primarily exhibits Mie scattering, it typically exhibits Rayleigh depolarization. However, in cancerous tissue the Mie depolarization regime becomes more prominent than Rayleigh. Experimental evidence of this metric is found in a preliminary clinical study using a novel Stokes polarimetry probe. We conducted in vivo measurements of 20 benign, 28 malignant and 59 normal skin sites with a 660 nm laser diode. The median PMR values for cancer vs non-cancer are significantly higher for cancer which supports our hypothesis. The reported fundamental differences in depolarization may persist for other types of cancer and create a conceptual basis for further developments in polarimetry applications for cancer detection.
Collapse
Affiliation(s)
- Daniel C. Louie
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, BC V6T 1Z4, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Departments of Cancer Control Research and Integrative Oncology, BC Cancer, Vancouver, BC V5Z 1L3, Canada
| | - Lioudmila Tchvialeva
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, BC V6T 1Z4, Canada
- Departments of Cancer Control Research and Integrative Oncology, BC Cancer, Vancouver, BC V5Z 1L3, Canada
| | - Sunil Kalia
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, BC V6T 1Z4, Canada
- Departments of Cancer Control Research and Integrative Oncology, BC Cancer, Vancouver, BC V5Z 1L3, Canada
| | - Harvey Lui
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, BC V6T 1Z4, Canada
- Departments of Cancer Control Research and Integrative Oncology, BC Cancer, Vancouver, BC V5Z 1L3, Canada
| | - Tim K. Lee
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, BC V6T 1Z4, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
- Departments of Cancer Control Research and Integrative Oncology, BC Cancer, Vancouver, BC V5Z 1L3, Canada
| |
Collapse
|
15
|
Chang S, Handwerker J, Giannico GA, Chang SS, Bowden AK. Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:074711. [PMID: 35064658 PMCID: PMC8781524 DOI: 10.1117/1.jbo.27.7.074711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Accepted: 12/22/2021] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Tissue birefringence is an important parameter to consider when designing realistic, tissue-mimicking phantoms. Options for suitable birefringent materials that can be used to accurately represent tissue scattering are limited. AIM To introduce a method of fabricating birefringent tissue phantoms with a commonly used material-polydimethylsiloxane (PDMS)-for imaging with polarization-sensitive optical coherence tomography (PS-OCT). APPROACH Stretch-induced birefringence was characterized in PDMS phantoms made with varying curing ratios, and the resulting phantom birefringence values were compared with those of biological tissues. RESULTS We showed that, with induced birefringence levels up to 2.1 × 10 - 4, PDMS can be used to resemble the birefringence levels in weakly birefringent tissues. We demonstrated the use of PDMS in the development of phantoms to mimic the normal and diseased bladder wall layers, which can be differentiated by their birefringence levels. CONCLUSIONS PDMS allows accurate control of tissue scattering and thickness, and it exhibits controllable birefringent properties. The use of PDMS as a birefringent phantom material can be extended to other birefringence imaging systems beyond PS-OCT and to mimic other organs.
Collapse
Affiliation(s)
- Shuang Chang
- Vanderbilt University, Vanderbilt Biophotonics Center, Department of Biomedical Engineering, Nashville, Tennessee, United States
| | - Jessica Handwerker
- Vanderbilt University, Vanderbilt Biophotonics Center, Department of Biomedical Engineering, Nashville, Tennessee, United States
| | - Giovanna A. Giannico
- Vanderbilt University Medical Center, Department of Pathology, Microbiology, and Immunology, Nashville, Tennessee, United States
| | - Sam S. Chang
- Vanderbilt University Medical Center, Department of Urology, Nashville, Tennessee, United States
| | - Audrey K. Bowden
- Vanderbilt University, Vanderbilt Biophotonics Center, Department of Biomedical Engineering, Nashville, Tennessee, United States
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| |
Collapse
|
16
|
Dong Y, Wan J, Wang X, Xue JH, Zou J, He H, Li P, Hou A, Ma H. A Polarization-Imaging-Based Machine Learning Framework for Quantitative Pathological Diagnosis of Cervical Precancerous Lesions. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3728-3738. [PMID: 34260351 DOI: 10.1109/tmi.2021.3097200] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Polarization images encode high resolution microstructural information even at low resolution. We propose a framework combining polarization imaging and traditional microscopy imaging, constructing a dual-modality machine learning framework that is not only accurate but also generalizable and interpretable. We demonstrate the viability of our proposed framework using the cervical intraepithelial neoplasia grading task, providing a polarimetry feature parameter to quantitatively characterize microstructural variations with lesion progression in hematoxylin-eosin-stained pathological sections of cervical precancerous tissues. By taking advantages of polarization imaging techniques and machine learning methods, the model enables interpretable and quantitative diagnosis of cervical precancerous lesion cases with improved sensitivity and accuracy in a low-resolution and wide-field system. The proposed framework applies routine image-analysis technology to identify the macro-structure and segment the target region in H&E-stained pathological images, and then employs emerging polarization method to extract the micro-structure information of the target region, which intends to expand the boundary of the current image-heavy digital pathology, bringing new possibilities for quantitative medical diagnosis.
Collapse
|
17
|
Ali Z, Mahmood T, Shahzad A, Iqbal M, Ahmad I. Assessment of tissue pathology using optical polarimetry. Lasers Med Sci 2021; 37:1907-1919. [PMID: 34689277 DOI: 10.1007/s10103-021-03450-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 10/18/2021] [Indexed: 11/28/2022]
Abstract
Optical polarimetry have been extensively used for the non-invasive assessment of biological tissues. However, the knowledge regarding differences in polarimetric signatures of different tissue pathologies is very scattered, confounding the deduction of a global trend of the polarimetric variables for healthy and pathological tissues. The purpose of this study was to bridge this gap. We conducted a rigorous online survey to collect all published studies that report the two most common polarimetric variables (i.e., depolarization and retardance) for any type of tissue pathology. A total of 101 studies describing the polarimetric assessment of tissues were collected, wherein 253 (i.e., nhuman = 149, nanimal = 104) different type of tissues were optically characterized. Most tissue samples (172/253) were investigated in ex vivo settings. The data showed 32 different types of tissues pathologies, where the most common pathology was cancer and its subtypes. The skin tissues were the most frequently explored tissues, followed by tissue samples from breast, colon, liver, and cervix. Although differences in polarimetric signatures of different tissue pathologies were summarized from the included studies, generalization of the results was hindered by the presentation of polarimetric data in a non-uniform format. The analyses presented in this study may provide an important reference for future polarimetric studies that conduct optical assessment of tissues at greater depth, particularly in the context of optical biopsy/digital staining.
Collapse
Affiliation(s)
- Zahra Ali
- DHQ and Teaching Hospital, Sahiwal, Pakistan
| | | | | | - Muaz Iqbal
- Department of Physics, Islamia College Peshawar, Khyber Pakhtunkhwa, Pakistan
| | - Iftikhar Ahmad
- Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar, Pakistan.
| |
Collapse
|
18
|
He C, He H, Chang J, Chen B, Ma H, Booth MJ. Polarisation optics for biomedical and clinical applications: a review. LIGHT, SCIENCE & APPLICATIONS 2021; 10:194. [PMID: 34552045 PMCID: PMC8458371 DOI: 10.1038/s41377-021-00639-x] [Citation(s) in RCA: 104] [Impact Index Per Article: 34.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 05/13/2023]
Abstract
Many polarisation techniques have been harnessed for decades in biological and clinical research, each based upon measurement of the vectorial properties of light or the vectorial transformations imposed on light by objects. Various advanced vector measurement/sensing techniques, physical interpretation methods, and approaches to analyse biomedically relevant information have been developed and harnessed. In this review, we focus mainly on summarising methodologies and applications related to tissue polarimetry, with an emphasis on the adoption of the Stokes-Mueller formalism. Several recent breakthroughs, development trends, and potential multimodal uses in conjunction with other techniques are also presented. The primary goal of the review is to give the reader a general overview in the use of vectorial information that can be obtained by polarisation optics for applications in biomedical and clinical research.
Collapse
Affiliation(s)
- Chao He
- Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK.
| | - Honghui He
- Guangdong Engineering Center of Polarisation Imaging and Sensing Technology, Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China.
- Institute of Biopharmaceutical and Health Engineering, Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China.
| | - Jintao Chang
- Guangdong Engineering Center of Polarisation Imaging and Sensing Technology, Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China
- Department of Physics, Tsinghua University, 100084, Beijing, China
| | - Binguo Chen
- Guangdong Engineering Center of Polarisation Imaging and Sensing Technology, Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China
- Department of Biomedical Engineering, Tsinghua University, 100084, Beijing, China
| | - Hui Ma
- Guangdong Engineering Center of Polarisation Imaging and Sensing Technology, Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China
- Institute of Biopharmaceutical and Health Engineering, Tsinghua Shenzhen International Graduate School, Tsinghua University, 518055, Shenzhen, China
- Department of Physics, Tsinghua University, 100084, Beijing, China
| | - Martin J Booth
- Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK.
| |
Collapse
|
19
|
Meng R, Shao C, Li P, Dong Y, Hou A, Li C, Lin L, He H, Ma H. Transmission Mueller matrix imaging with spatial filtering. OPTICS LETTERS 2021; 46:4009-4012. [PMID: 34388798 DOI: 10.1364/ol.435166] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 07/11/2021] [Indexed: 06/13/2023]
Abstract
In this Letter, we report a study on the effects of spatial filtering for a transmission Mueller matrix imaging system. A spatial filter (SF) is placed on the back Fourier plane of the imaging lens in a dual-rotating-retarders Mueller matrix imaging system to select photons within a certain scattering angle. The system is then applied to three types of human cancerous tissues. When imaging with a small-aperture SF, some polarimetry basis parameters show sharp changes in contrast in the cancerous regions. Monte Carlo simulations using a simple sphere-cylinder scattering model also show that spatial filtering of the scattered photons provides extra information on the size and shape of the scattering particles. The results indicate that spatial filtering enhances the capability of polarization imaging as a powerful tool for biomedical diagnosis.
Collapse
|
20
|
Zhu Y, Dong Y, Yao Y, Si L, Liu Y, He H, Ma H. Probing layered structures by multi-color backscattering polarimetry and machine learning. BIOMEDICAL OPTICS EXPRESS 2021; 12:4324-4339. [PMID: 34457417 PMCID: PMC8367275 DOI: 10.1364/boe.425614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/06/2021] [Accepted: 06/17/2021] [Indexed: 05/10/2023]
Abstract
Polarization imaging can quantitatively probe the characteristic microstructural features of biological tissues non-invasively. In biomedical tissues, layered structures are common. Superposition of two simple layers can result in a complex Mueller matrix, and multi-color backscattering polarimetry can help to probe layered structures. In this work, multi-color backscattering Mueller matrix images are measured for living nude mice skins. Preliminary analysis of anisotropy parameter A and linear polarizance parameter b show signs of a layered structure in the skin. For more detailed examinations on polarization features of layered samples, we generate Mueller matrices by experimenting with two-layered thick tissues and concentrically aligned silk submerged in milk. Then we use supervised machine learning to identify polarization parameters that are sensitive to layered structure and guide the synthesis of more parameters. Monte Carlo simulation is also adopted to explore the relationship between parameters and microstructures of media. We conclude that multi-color backscattering polarimetry combined with supervised machine learning can be applied to probe the characteristic microstructure in layered living tissue samples.
Collapse
Affiliation(s)
- Yuanhuan Zhu
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
| | - Yang Dong
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
| | - Yue Yao
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
| | - Lu Si
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
| | - Yudi Liu
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
| | - Honghui He
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Hui Ma
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
- Department of Physics, Tsinghua University, Beijing 100084, China
| |
Collapse
|
21
|
Ning B, Kim WW, Katz I, Park CH, Sandler AD, Cha J. Improved Nerve Visualization in Head and Neck Surgery Using Mueller Polarimetric Imaging: Preclinical Feasibility Study in a Swine Model. Lasers Surg Med 2021; 53:1427-1434. [PMID: 34036583 DOI: 10.1002/lsm.23422] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 04/02/2021] [Accepted: 05/09/2021] [Indexed: 11/11/2022]
Abstract
BACKGROUND AND OBJECTIVES Meticulous dissection and identification of nerves during head and neck surgery are crucial for preventing nerve damage. At present, nerve identification relies heavily on the surgeon's knowledge of anatomy, optionally combined with intraoperative neuromonitoring. Recently, optical techniques such as Mueller polarimetric imaging (MPI) have shown potential to improve nerve identification. STUDY DESIGN/MATERIALS AND METHODS With institutional approval, seven 25-35 kg Yorkshire pigs underwent cervical incision in the central neck. Intraoperative images were obtained using our in-house MPI system. Birefringence maps from the MPI system were processed to quantify the values between 0 and 255 from different tissue types; an active contour model was applied to further improve nerve visualization on the corresponding color images. RESULTS Among the seven pigs, the vagus nerves and recurrent laryngeal nerves were successfully differentiated with a mean intensity of 130.954 ± 20.611, which was significantly different (P < 0.05) from those of arteries (78.512 ± 27.78) and other surrounding tissues (82.583 ± 35.547). There were no imaging-related complications during the procedure. © 2021 Wiley Periodicals LLC. CONCLUSIONS MPI is a potentially complementary intraoperative tool for nerve identification in adjacent tissues.
Collapse
Affiliation(s)
- Bo Ning
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, 111 Michigan Avenue NW, Washington, District of Columbia, 20010
| | - Wan Wook Kim
- Department of Surgery, Kyungpook National University Chilgok Hospital, 807 Hoguk-ro Buk-gu, Daegu, 41404, South Korea
| | - Itai Katz
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, 111 Michigan Avenue NW, Washington, District of Columbia, 20010
| | - Chung Hyuk Park
- Department of Biomedical Engineering, George Washington University, 800 22nd Street NW, Washington, District of Columbia, 20052
| | - Anthony D Sandler
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, 111 Michigan Avenue NW, Washington, District of Columbia, 20010
| | - Jaepyeong Cha
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, 111 Michigan Avenue NW, Washington, District of Columbia, 20010.,Department of Pediatrics, George Washington University School of Medicine and Health Sciences, 2300 I St NW, Washington, District of Columbia, 20052
| |
Collapse
|
22
|
Sharma M, Narayanan Unni S, Balasubramanian S, Sundaram S, Krishnamurthy P, Hegde A. Histopathological correlations of bulk tissue polarimetric images: Case study. JOURNAL OF BIOPHOTONICS 2021; 14:e202000475. [PMID: 33533565 DOI: 10.1002/jbio.202000475] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 02/02/2021] [Accepted: 02/02/2021] [Indexed: 06/12/2023]
Abstract
Polarimetric imaging and image analysis have gained increased interest in soft tissue analysis at the cellular level. However, polarimetric imaging has widely been tested on thin tissue sections to provide reliable information correlated with histopathological findings. Polarimetric bulk tissue analysis always offered an overall assessment of various tissue optical properties for diagnosis. In this study, the histopathological correlation of bulk tissue polarimetry images for soft tissues is discussed. The first-hand information on the use of bulk tissue Mueller polarimetry and image analysis as an alternative to tissue histopathology is presented for surgically extracted colon and breast tissues.
Collapse
Affiliation(s)
- Mahima Sharma
- Biophotonics Lab, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Sujatha Narayanan Unni
- Biophotonics Lab, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Subalakshmi Balasubramanian
- Department of Pathology, Sri Ramachandra Medical College and Research Institute, SRIHER, Porur, Chennai, India
| | - Sandhya Sundaram
- Department of Pathology, Sri Ramachandra Medical College and Research Institute, SRIHER, Porur, Chennai, India
| | - Priya Krishnamurthy
- Biophotonics Lab, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Anoosha Hegde
- Biophotonics Lab, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| |
Collapse
|
23
|
Dong Y, Wan J, Si L, Meng Y, Dong Y, Liu S, He H, Ma H. Deriving Polarimetry Feature Parameters to Characterize Microstructural Features in Histological Sections of Breast Tissues. IEEE Trans Biomed Eng 2021; 68:881-892. [PMID: 32845834 DOI: 10.1109/tbme.2020.3019755] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Mueller matrix polarimetry technique has been regarded as a powerful tool for probing the microstructural information of tissues. The multiplying of cells and remodeling of collagen fibers in breast carcinoma tissues have been reported to be related to patient survival and prognosis, and they give rise to observable patterns in hematoxylin and eosin (H&E) sections of typical breast tissues (TBTs) that the pathologist can label as three distinctive pathological features (DPFs)-cell nuclei, aligned collagen, and disorganized collagen. The aim of this paper is to propose a pixel-based extraction approach of polarimetry feature parameters (PFPs) using a linear discriminant analysis (LDA) classifier. These parameters provide quantitative characterization of the three DPFs in four types of TBTs. METHODS The LDA-based training method learns to find the most simplified linear combination from polarimetry basis parameters (PBPs) constrained under the accuracy remains constant to characterize the specific microstructural feature quantitatively in TBTs. RESULTS We present results from a cohort of 32 clinical patients with analysis of 224 regions-of-interest. The characterization accuracy for PFPs ranges from 0.82 to 0.91. CONCLUSION This work demonstrates the ability of PFPs to quantitatively characterize the DPFs in the H&E pathological sections of TBTs. SIGNIFICANCE This technique paves the way for automatic and quantitative evaluation of specific microstructural features in histopathological digitalization and computer-aided diagnosis.
Collapse
|
24
|
Meng R, Chen Z, Wang X, Liu Y, He H, Ma H. Comparison of different calibration methods for Mueller matrix microscopy of cells. APPLIED OPTICS 2021; 60:1380-1386. [PMID: 33690582 DOI: 10.1364/ao.411625] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 01/11/2021] [Indexed: 06/12/2023]
Abstract
Mueller matrix (MM) imaging has demonstrated its potential application in much research, especially in probing delicate and complex biomedical specimens. Qualities of MM images are important for further quantitative characterization. In this paper, we compare the performance and imaging qualities of three calibration methods. Air, waveplate and cell specimen are selected as standard samples for comparison. In addition, we also propose two general MM imaging quality indices that can be used as quantitative evaluations for MM imaging systems and calculation processes based on real samples. The numerical calibration method turns out to give the best accuracy and precision, as well as the best image qualities.
Collapse
|
25
|
Shen Y, Huang R, He H, Liu S, Dong Y, Wu J, Ma H. Comparative study of the influence of imaging resolution on linear retardance parameters derived from the Mueller matrix. BIOMEDICAL OPTICS EXPRESS 2021; 12:211-225. [PMID: 33659076 PMCID: PMC7899522 DOI: 10.1364/boe.410989] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 11/13/2020] [Accepted: 12/02/2020] [Indexed: 05/07/2023]
Abstract
Polarization imaging techniques are emerging tools to provide quantitative information of anisotropic structures, such as the density and orientation distribution of fibers in tissue samples. Recently, it is found that when using Mueller matrix polarimetry to obtain the structural features of tissue samples, some information can be revealed by relatively low-resolution polarization parameter images. Thus, to analyze what kinds of anisotropic optical and structural information contained in high-resolution polarization images are preserved in low-resolution ones, here we carry out a comparative study of the influence of imaging resolution on the Mueller matrix derived linear retardance parameters. We measure the microscopic Mueller matrix of human healthy breast duct tissues and ductal carcinoma in situ (DCIS) tissues, which have distinct typical fibrous structures, using objectives with different numerical aperture. Then we quantitatively compare a group of image texture feature parameters of the linear retardance parameters images under high and low imaging resolutions. The results demonstrate that the fibers density information contained in the texture features of linear retardance δ parameter image are preserved well with the decline of imaging resolution. While for the azimuthal orientation parameter θ which closely related to the spatial location, we still need high imaging resolution to obtain quantitative structural information. The study provides an important criterion to decide which information of fibrous structures can be extracted accurately using transmission Mueller matrix microscope with low numerical aperture objectives.
Collapse
Affiliation(s)
- Yuanxing Shen
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong 518055, China
- Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
- These authors contributed equally to this work
| | - Rongrong Huang
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong 518055, China
- Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
- These authors contributed equally to this work
| | - Honghui He
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong 518055, China
| | - Shaoxiong Liu
- Shenzhen Sixth People's Hospital (Nanshan Hospital), Huazhong University of Science and Technology Union Shenzhen Hospital, Shenzhen, Guangdong 518052, China
| | - Yang Dong
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen, Guangdong 518071, China
| | - Jian Wu
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong 518055, China
| | - Hui Ma
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong 518055, China
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen, Guangdong 518071, China
- Department of Physics, Tsinghua University, Beijing 100084, China
| |
Collapse
|
26
|
Buckley C, Fabert M, Kinet D, Kucikas V, Pagnoux D. Design of an endomicroscope including a resonant fiber-based microprobe dedicated to endoscopic polarimetric imaging for medical diagnosis. BIOMEDICAL OPTICS EXPRESS 2020; 11:7032-7052. [PMID: 33408978 PMCID: PMC7747912 DOI: 10.1364/boe.403157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 10/27/2020] [Accepted: 10/27/2020] [Indexed: 05/06/2023]
Abstract
We report on a novel endomicroscope, to the best of our knowledge, designed for achieving full 4×4 Mueller polarimetric images of biological tissues through a fiber endoscope for medical diagnosis. The polarimetric technique is based on a previously published two-wavelength differential method (TWDM). A key component of the endomicroscope is a resonant fiber-based microprobe including a highly-selective fiber Bragg grating (FBG), free of detrimental polarimetric effects, photo written in the core of the fiber, near the output face. By means of the TWDM, and using the specially designed microprobe (diameter 2.9 mm, length 30 mm), full Mueller images of 250×250 pixels were produced at the rate of 1 image/2 s through a 2 m single mode fiber, paving the way to in vivo applications in polarimetric endomicroscopy.
Collapse
Affiliation(s)
- Colman Buckley
- University of Limoges, CNRS, Xlim, UMR 7252, F-87000 Limoges, France
| | - Marc Fabert
- University of Limoges, CNRS, Xlim, UMR 7252, F-87000 Limoges, France
| | - Damien Kinet
- University of Mons, Faculté Polytechnique, Bd Dolez 31, B-7000 Mons, Belgium
| | - Vytautas Kucikas
- University of Limoges, CNRS, Xlim, UMR 7252, F-87000 Limoges, France
- RWTH Aachen University, Institute for Molecular Cardiovascular Research (IMCAR), Aachen, Germany
| | - Dominique Pagnoux
- University of Limoges, CNRS, Xlim, UMR 7252, F-87000 Limoges, France
| |
Collapse
|
27
|
Jiao Y, Kandel ME, Liu X, Lu W, Popescu G. Real-time Jones phase microscopy for studying transparent and birefringent specimens. OPTICS EXPRESS 2020; 28:34190-34200. [PMID: 33182894 PMCID: PMC7679182 DOI: 10.1364/oe.397062] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Tissue birefringence is an intrinsic marker of potential value for cancer diagnosis. Traditionally, birefringence properties have been studied by using intensity-based formalisms, through the Mueller matrix algebra. On the other hand, the Jones matrix description allows for a direct assessment of the sample's anisotropic response. However, because Jones algebra is based on complex fields, requiring measurements of both phase and amplitude, it is less commonly used. Here we propose a real-time imaging method for measuring Jones matrices by quantitative phase imaging. We combine a broadband phase imaging system with a polarization-sensitive detector to obtain Jones matrices at each point in a megapixel scale image, with near video rate capture speeds. To validate the utility of our approach, we measured standard targets, partially birefringent samples, dynamic specimens, and thinly sliced histopathological tissue.
Collapse
Affiliation(s)
- Yuheng Jiao
- Quantitative Light Laboratory, Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, the University of Illinois at Urbana-Champaign, Illinois 61801, USA
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Mikhail E. Kandel
- Quantitative Light Laboratory, Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, the University of Illinois at Urbana-Champaign, Illinois 61801, USA
| | - Xiaojun Liu
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wenlong Lu
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Gabriel Popescu
- Quantitative Light Laboratory, Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, the University of Illinois at Urbana-Champaign, Illinois 61801, USA
| |
Collapse
|
28
|
Gordon GSD, Joseph J, Alcolea MP, Sawyer T, Williams C, Fitzpatrick CRM, Jones PH, di Pietro M, Fitzgerald RC, Wilkinson TD, Bohndiek SE. Quantitative phase and polarization imaging through an optical fiber applied to detection of early esophageal tumorigenesis. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-13. [PMID: 31840442 PMCID: PMC7006047 DOI: 10.1117/1.jbo.24.12.126004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Accepted: 11/18/2019] [Indexed: 05/30/2023]
Abstract
Phase and polarization of coherent light are highly perturbed by interaction with microstructural changes in premalignant tissue, holding promise for label-free detection of early tumors in endoscopically accessible tissues such as the gastrointestinal tract. Flexible optical multicore fiber (MCF) bundles used in conventional diagnostic endoscopy and endomicroscopy scramble phase and polarization, restricting clinicians instead to low-contrast amplitude-only imaging. We apply a transmission matrix characterization approach to produce full-field en-face images of amplitude, quantitative phase, and resolved polarimetric properties through an MCF. We first demonstrate imaging and quantification of biologically relevant amounts of optical scattering and birefringence in tissue-mimicking phantoms. We present an entropy metric that enables imaging of phase heterogeneity, indicative of disordered tissue microstructure associated with early tumors. Finally, we demonstrate that the spatial distribution of phase and polarization information enables label-free visualization of early tumors in esophageal mouse tissues, which are not identifiable using conventional amplitude-only information.
Collapse
Affiliation(s)
- George S. D. Gordon
- University of Cambridge, Department of Engineering, Cambridge, United Kingdom
| | - James Joseph
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| | - Maria P. Alcolea
- University of Cambridge, Wellcome Trust MRC Stem Cell Institute, Cambridge, United Kingdom
| | - Travis Sawyer
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| | - Calum Williams
- University of Cambridge, Department of Engineering, Cambridge, United Kingdom
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom
| | | | - Philip H. Jones
- University of Cambridge, MRC Cancer Unit, Hutchison/MRC Research Centre, Cambridge, United Kingdom
| | - Massimiliano di Pietro
- University of Cambridge, MRC Cancer Unit, Hutchison/MRC Research Centre, Cambridge, United Kingdom
| | - Rebecca C. Fitzgerald
- University of Cambridge, MRC Cancer Unit, Hutchison/MRC Research Centre, Cambridge, United Kingdom
| | | | - Sarah E. Bohndiek
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| |
Collapse
|
29
|
Liu T, Lu M, Chen B, Zhong Q, Li J, He H, Mao H, Ma H. Distinguishing structural features between Crohn's disease and gastrointestinal luminal tuberculosis using Mueller matrix derived parameters. JOURNAL OF BIOPHOTONICS 2019; 12:e201900151. [PMID: 31465142 DOI: 10.1002/jbio.201900151] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 08/26/2019] [Accepted: 08/28/2019] [Indexed: 05/02/2023]
Abstract
Recently, the incidence of inflammatory bowel diseases, especially the Crohn's disease (CD) and gastrointestinal luminal tuberculosis (ITB), has grown rapidly worldwide. Currently there is no general gold standard to distinguish between CD and ITB tissues, which both have tuberculosis and surrounding fibrous structures. Mueller matrix imaging technique is suitable for describing the location, density and distribution behavior of such fibrous structures. In this study, we apply the Mueller matrix microscopic imaging to the CD and ITB tissue samples. The 2D Mueller matrix images of the CD and ITB tissue slices are measured using the Mueller matrix microscope developed in our previous study, then the Mueller matrix polar decomposition and Mueller matrix transformation parameters are calculated. To evaluate the distribution features of the fibrous structures surrounding the tuberculosis areas more quantitatively and precisely, we analyze the retardance related Mueller matrix derived parameters, which show clear different distribution behaviors between the CD and ITB tissues, using the Tamura image processing method. It is demonstrated that the Mueller matrix derived parameters can reveal the structural features of tuberculosis areas and be used as quantitative indicators to distinguish between CD and ITB tissues, which may be useful for the clinical diagnosis.
Collapse
Affiliation(s)
- Teng Liu
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Physics, Tsinghua University, Beijing, China
| | - Min Lu
- Department of Gastroenterology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Binguo Chen
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Qinsong Zhong
- Department of Pathology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Jingyu Li
- Department of Pathology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Honghui He
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
| | - Hua Mao
- Department of Gastroenterology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Hui Ma
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Physics, Tsinghua University, Beijing, China
- Center for Precision Medicine and Healthcare, Tsinghua-Berkeley Shenzhen Institute, Shenzhen, China
| |
Collapse
|
30
|
Gordon GSD, Joseph J, Sawyer T, Macfaden AJ, Williams C, Wilkinson TD, Bohndiek SE. Full-field quantitative phase and polarisation-resolved imaging through an optical fibre bundle. OPTICS EXPRESS 2019; 27:23929-23947. [PMID: 31510290 PMCID: PMC6825613 DOI: 10.1364/oe.27.023929] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 07/11/2019] [Accepted: 07/11/2019] [Indexed: 05/06/2023]
Abstract
Flexible optical fibres, used in conventional medical endoscopy and industrial inspection, scramble phase and polarisation information, restricting users to amplitude-only imaging. Here, we exploit the near-diagonality of the multi-core fibre (MCF) transmission matrix in a parallelised fibre characterisation architecture, enabling accurate imaging of quantitative phase (error <0.3 rad) and polarisation-resolved (errors <10%) properties. We first demonstrate accurate recovery of optical amplitude and phase in two polarisations through the MCF by measuring and inverting the transmission matrix, and then present a robust Bayesian inference approach to resolving 5 polarimetric properties of samples. Our method produces high-resolution (9.0±2.6μm amplitude, phase; 36.0±10.4μm polarimetric) full-field images at working distances up to 1mm over a field-of-view up to 750×750μm 2 using an MCF with potential for flexible operation. We demonstrate the potential of using quantitative phase for computational image focusing and polarisation-resolved properties in imaging birefringence.
Collapse
Affiliation(s)
- George S. D. Gordon
- Now at: Department of Electrical and Electronic Engineering, The University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge, CB3 0FA, UK
| | - James Joseph
- Department of Physics, Cavendish Laboratory, JJ Thomson Avenue, Cambridge, CB3 0HE, UK
- Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Robinson Way, Cambridge, CB2 0RE, UK
| | - Travis Sawyer
- Department of Physics, Cavendish Laboratory, JJ Thomson Avenue, Cambridge, CB3 0HE, UK
| | - Alexander J. Macfaden
- Now at: Department of Electrical and Electronic Engineering, The University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Calum Williams
- Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge, CB3 0FA, UK
- Department of Physics, Cavendish Laboratory, JJ Thomson Avenue, Cambridge, CB3 0HE, UK
| | - Timothy D. Wilkinson
- Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge, CB3 0FA, UK
| | - Sarah E. Bohndiek
- Department of Physics, Cavendish Laboratory, JJ Thomson Avenue, Cambridge, CB3 0HE, UK
- Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Robinson Way, Cambridge, CB2 0RE, UK
| |
Collapse
|
31
|
Gataric M, Gordon GSD, Renna F, Ramos AGCP, Alcolea MP, Bohndiek SE. Reconstruction of Optical Vector-Fields With Applications in Endoscopic Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:955-967. [PMID: 30334753 PMCID: PMC6456146 DOI: 10.1109/tmi.2018.2875875] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 10/09/2018] [Indexed: 05/03/2023]
Abstract
We introduce a framework for the reconstruction of the amplitude, phase, and polarization of an optical vector-field using measurements acquired by an imaging device characterized by an integral transform with an unknown spatially variant kernel. By incorporating effective regularization terms, this new approach is able to recover an optical vector-field with respect to an arbitrary representation system, which may be different from the one used for device calibration. In particular, it enables the recovery of an optical vector-field with respect to a Fourier basis, which is shown to yield indicative features of increased scattering associated with tissue abnormalities. We demonstrate the effectiveness of our approach using synthetic holographic images and biological tissue samples in an experimental setting, where the measurements of an optical vector-field are acquired by a multicore fiber endoscope, and observe that indeed the recovered Fourier coefficients are useful in distinguishing healthy tissues from tumors in early stages of oesophageal cancer.
Collapse
|
32
|
Quantitative Analysis of 4 × 4 Mueller Matrix Transformation Parameters for Biomedical Imaging. PHOTONICS 2019. [DOI: 10.3390/photonics6010034] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Mueller matrix polarimetry is a potentially powerful technique for obtaining microstructural information of biomedical specimens. Thus, it has found increasing application in both backscattering imaging of bulk tissue samples and transmission microscopic imaging of thin tissue slices. Recently, we proposed a technique to transform the 4 × 4 Mueller matrix elements into a group of parameters, which have explicit associations with specific microstructural features of samples. In this paper, we thoroughly analyze the relationships between the Mueller matrix transformation parameters and the characteristic microstructures of tissues by using experimental phantoms and Monte Carlo simulations based on different tissue mimicking models. We also adopt quantitative evaluation indicators to compare the Mueller matrix transformation parameters with the Mueller matrix polar decomposition parameters. The preliminary imaging results of bulk porcine colon tissues and thin human pathological tissue slices demonstrate the potential of Mueller matrix transformation parameters as biomedical diagnostic indicators. Also, this study provides quantitative criteria for parameter selection in biomedical Mueller matrix imaging.
Collapse
|
33
|
K. U. S, Mahato KK, Mazumder N. Polarization-resolved Stokes-Mueller imaging: a review of technology and applications. Lasers Med Sci 2019; 34:1283-1293. [DOI: 10.1007/s10103-019-02752-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 02/12/2019] [Indexed: 12/15/2022]
|
34
|
Chue-Sang J, Gonzalez M, Pierre A, Laughrey M, Saytashev I, Novikova T, Ramella-Roman JC. Optical phantoms for biomedical polarimetry: a review. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-12. [PMID: 30851015 PMCID: PMC6975228 DOI: 10.1117/1.jbo.24.3.030901] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Accepted: 01/29/2019] [Indexed: 05/04/2023]
Abstract
Calibration, quantification, and standardization of the polarimetric instrumentation, as well as interpretation and understanding of the obtained data, require the development and use of well-calibrated phantoms and standards. We reviewed the status of tissue phantoms for a variety of applications in polarimetry; more than 500 papers are considered. We divided the phantoms into five groups according to their origin (biological/nonbiological) and fundamental polarimetric properties of retardation, depolarization, and diattenuation. We found that, while biological media are generally depolarizing, retarding, and diattenuating, only one of all the phantoms reviewed incorporated all these properties, and few considered at least combined retardation and depolarization. Samples derived from biological tissue, such as tendon and muscle, remain extremely popular to quickly ascertain a polarimetric system, but do not provide quantifiable results aside from relative direction of their principal optical axis. Microspheres suspensions are the most utilized phantoms for depolarization, and combined with theoretical models can offer true quantification of depolarization or degree of polarization. There is a real paucity of birefringent phantoms despite the retardance being one of the most interesting parameters measurable with polarization techniques. Therefore, future work should be directed at generating truly reliable and repeatable phantoms for this metric determination. Diattenuating phantoms are rare and application-specific. Given that diattenuation is considered to be low in most biological tissues, the lack of such phantoms is seen as less problematic. The heterogeneity of the phantoms reviewed points to a critical need for standardization in this field. Ultimately, all research groups involved in polarimetric studies and instruments development would benefit from sharing a limited set of standardized polarimetric phantoms, as is done earlier in the round robin investigations in ellipsometry.
Collapse
Affiliation(s)
- Joseph Chue-Sang
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | - Mariacarla Gonzalez
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | - Angie Pierre
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | - Megan Laughrey
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | - Ilyas Saytashev
- Florida International University, Herbert Wertheim College of Medicine, Miami, Florida, United States
| | - Tatiana Novikova
- LPICM Laboratoire de Physique des Interfaces et Couches Minces, CNRS, Ecole Polytechnique, Palaiseau, France
| | - Jessica C. Ramella-Roman
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
- Florida International University, Herbert Wertheim College of Medicine, Miami, Florida, United States
| |
Collapse
|
35
|
Sun T, Liu T, He H, Wu J, Ma H. Distinguishing anisotropy orientations originated from scattering and birefringence of turbid media using Mueller matrix derived parameters. OPTICS LETTERS 2018; 43:4092-4095. [PMID: 30160724 DOI: 10.1364/ol.43.004092] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Accepted: 07/18/2018] [Indexed: 05/27/2023]
Abstract
Anisotropic structures such as myofibrils, collagen, and elastic fibers are prevalent in tissues. The orientations of these anisotropic structures are important indicators in various biomedical studies. Here we analyze the ability of using Mueller matrix polar decomposition (MMPD) and Mueller matrix transformation (MMT) parameters to determine and distinguish the accurate orientations of different anisotropies originated from scattering and birefringence in backscattering measurements. The experimental results of complex phantoms and Monte Carlo simulations suggest that the MMT and MMPD parameters can be used to reveal the orientations of the cylindrical scatterers and birefringence in turbid media, respectively. Moreover, a preliminary application of these Mueller matrix-derived parameters on bovine tendon samples demonstrates the ability of using the parameters to distinguish anisotropic scattering and birefringence orientations of tissues. The anisotropy orientation information can be helpful for biomedical studies or diagnosis.
Collapse
|
36
|
Liu T, Sun T, He H, Liu S, Dong Y, Wu J, Ma H. Comparative study of the imaging contrasts of Mueller matrix derived parameters between transmission and backscattering polarimetry. BIOMEDICAL OPTICS EXPRESS 2018; 9:4413-4428. [PMID: 30615708 PMCID: PMC6157769 DOI: 10.1364/boe.9.004413] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 08/16/2018] [Accepted: 08/17/2018] [Indexed: 05/02/2023]
Abstract
Mueller matrix polarimetry is a potentially powerful tool for biomedical diagnosis. Recently, the transmission Mueller matrix microscope and backscattering Mueller matrix endoscope were developed and applied to various pathological samples. However, a comparative study of imaging contrasts of Mueller matrix derived parameters between transmission and backscattering measurements is still needed to help decide which information obtained from transmission Mueller matrix microscope can be directly applied to in vivo Mueller matrix imaging. Here, to compare the imaging contrasts of Mueller matrix derived parameters between transmission and backscattering polarimetry, we measure porcine liver tissue samples and human breast carcinoma tissue specimens. The experiments and corresponding Monte Carlo stimulation results demonstrate that the backscattering and transmission retardance-related Mueller matrix parameters have very similar contrasts to characterize the anisotropic and isotropic structures of pathological tissues, meaning that the conclusions made from Mueller matrix microscopic imaging based on retardance can also be helpful to guide the in situ backscattering Mueller matrix polarimetric diagnosis. However, the values and contrasts of depolarization-related Mueller matrix parameters have some differences between transmission and backscattering polarimetry.
Collapse
Affiliation(s)
- Teng Liu
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
- Department of Physics, Tsinghua University, Beijing 100084, China
- These authors contributed equally to this work
| | - Tao Sun
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
- Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
- These authors contributed equally to this work
| | - Honghui He
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Shaoxiong Liu
- Shenzhen Sixth People’s Hospital (Nanshan Hospital), Huazhong University of Science and Technology Union Shenzhen Hospital, Shenzhen 518052, China
| | - Yang Dong
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
- Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
| | - Jian Wu
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Hui Ma
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
- Department of Physics, Tsinghua University, Beijing 100084, China
- Center for Precision Medicine and Healthcare, Tsinghua-Berkeley Shenzhen Institute, Shenzhen, China
| |
Collapse
|
37
|
Badieyan S, Dilmaghani-Marand A, Hajipour MJ, Ameri A, Razzaghi MR, Rafii-Tabar H, Mahmoudi M, Sasanpour P. Detection and Discrimination of Bacterial Colonies with Mueller Matrix Imaging. Sci Rep 2018; 8:10815. [PMID: 30018335 PMCID: PMC6050273 DOI: 10.1038/s41598-018-29059-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 07/05/2018] [Indexed: 01/05/2023] Open
Abstract
The polarization imaging technique is a powerful approach to probe microstructural and optical information of biological structures (e.g., tissue samples). Here, we have studied the polarization properties of different bacterial colonies in order to evaluate the possibility of bacterial detection and discrimination. In this regard, we have taken the backscattering Mueller matrix images of four different bacteria colonies (i.e., Escherichia coli, Lactobacillus rhamnosus, Rhodococcus erythropolis, and Staphylococcus aureus). Although the images have the potential to distinguish qualitatively different bacterial colonies, we explored more accurate and quantitative parameters criteria for discrimination of bacterial samples; more specifically, we have exploited the Mueller matrix polar decomposition (MMPD),frequency distribution histogram (FDH), and central moment analysis method. The outcomes demonstrated a superior capacity of Mueller matrix imaging, MMPD, and FDH in bacterial colonies identification and discrimination. This approach might pave the way for a reliable, efficient, and cheap way of identification of infectious diseases.
Collapse
Affiliation(s)
- Saeedesadat Badieyan
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Arezou Dilmaghani-Marand
- Non-Communicable Diseases Research Center, Endocrinology and Metabolism Population Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Javad Hajipour
- Non-Communicable Diseases Research Center, Endocrinology and Metabolism Population Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran. .,Persian Gulf Marine Biotechnology Research Center, The Persian Gulf Biomedical Sciences Research Institute, Bushehr University of Medical Sciences, Bushehr, Iran.
| | - Ali Ameri
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mohammad Reza Razzaghi
- Department of Urology, Shohada-e-Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hashem Rafii-Tabar
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Morteza Mahmoudi
- Department of Anesthesiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, 02115, United States.
| | - Pezhman Sasanpour
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran. .,School of Nanoscience, Institute for Research in Fundamental Sciences (IPM), Tehran, Iran.
| |
Collapse
|
38
|
Waterhouse DJ, Fitzpatrick CRM, di Pietro M, Bohndiek SE. Emerging optical methods for endoscopic surveillance of Barrett's oesophagus. Lancet Gastroenterol Hepatol 2018; 3:349-362. [PMID: 29644977 DOI: 10.1016/s2468-1253(18)30030-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 12/21/2017] [Accepted: 01/22/2018] [Indexed: 12/11/2022]
Abstract
Barrett's oesophagus is an acquired metaplastic condition that predisposes patients to the development of oesophageal adenocarcinoma, prompting the use of surveillance regimes to detect early malignancy for endoscopic therapy with curative intent. The currently accepted surveillance regime uses white light endoscopy together with random biopsies, but has poor sensitivity and discards information from numerous light-tissue interactions that could be exploited to probe structural, functional, and molecular changes in the tissue. Advanced optical methods are now emerging that are highly sensitive to these changes and hold potential to improve surveillance of Barrett's oesophagus if they can be applied endoscopically. The next decade will see some of these exciting new methods applied to surveillance of Barrett's oesophagus in new device architectures for the first time, potentially leading to a long-awaited improvement in the standard of care.
Collapse
Affiliation(s)
- Dale J Waterhouse
- Department of Physics, University of Cambridge, Cambridge, UK; Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK
| | - Catherine R M Fitzpatrick
- Department of Physics, University of Cambridge, Cambridge, UK; Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK; Department of Electrical Engineering, University of Cambridge, Cambridge, UK
| | | | - Sarah E Bohndiek
- Department of Physics, University of Cambridge, Cambridge, UK; Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK.
| |
Collapse
|
39
|
Van Eeckhout A, Lizana A, Garcia-Caurel E, Gil JJ, Sansa A, Rodríguez C, Estévez I, González E, Escalera JC, Moreno I, Campos J. Polarimetric imaging of biological tissues based on the indices of polarimetric purity. JOURNAL OF BIOPHOTONICS 2018; 11:e201700189. [PMID: 28981211 DOI: 10.1002/jbio.201700189] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 10/02/2017] [Accepted: 10/03/2017] [Indexed: 05/02/2023]
Abstract
We highlight the interest of using the indices of polarimetric purity (IPPs) to the inspection of biological tissues. The IPPs were recently proposed in the literature and they result in a further synthetization of the depolarizing properties of samples. Compared with standard polarimetric images of biological samples, IPP-based images lead to larger image contrast of some biological structures and to a further physical interpretation of the depolarizing mechanisms inherent to the samples. In addition, unlike other methods, their calculation do not require advanced algebraic operations (as is the case of polar decompositions), and they result in 3 indicators of easy implementation. We also propose a pseudo-colored encoding of the IPP information that leads to an improved visualization of samples. This last technique opens the possibility of tailored adjustment of tissues contrast by using customized pseudo-colored images. The potential of the IPP approach is experimentally highlighted along the manuscript by studying 3 different ex-vivo samples. A significant image contrast enhancement is obtained by using the IPP-based methods, compared to standard polarimetric images.
Collapse
Affiliation(s)
- Albert Van Eeckhout
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Angel Lizana
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Enric Garcia-Caurel
- LPICM, CNRS, École Polytechnique, Université Paris-Saclay, Palaiseau, France
| | - José J Gil
- Laboratory of Polarimetry, ICE Universidad de Zaragoza, Zaragoza, Spain
| | - Adrià Sansa
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Carla Rodríguez
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Irene Estévez
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Emilio González
- Departamento de Anatomía, Histología y Neurociencia, Universidad Autónoma de Madrid, Madrid, Spain
- Servicio de Anatomía Patológica, Hospital Universitario de Canarias, Santa Cruz de Tenerife, Spain
| | - Juan C Escalera
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Ignacio Moreno
- Departamento de Ciencia de Materiales, Óptica y Tecnología Electrónica, Universidad Miguel Hernández de Elche, Elche, Spain
| | - Juan Campos
- Grup d'Òptica, Physics Department, Universitat Autònoma de Barcelona, Bellaterra, Spain
| |
Collapse
|
40
|
Qi J, He H, Lin J, Dong Y, Chen D, Ma H, Elson DS. Assessment of tissue polarimetric properties using Stokes polarimetric imaging with circularly polarized illumination. JOURNAL OF BIOPHOTONICS 2018; 11:e201700139. [PMID: 29131523 DOI: 10.1002/jbio.201700139] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2017] [Accepted: 11/09/2017] [Indexed: 05/02/2023]
Abstract
Tissue-depolarization and linear-retardance are the main polarization characteristics of interest for bulk tissue characterization, and are normally interpreted from Mueller polarimetry. Stokes polarimetry can be conducted using simpler instrumentation and in a shorter time. Here, we use Stokes polarimetric imaging with circularly polarized illumination to assess the circular-depolarization and linear-retardance properties of tissue. Results obtained were compared with Mueller polarimetry in transmission and reflection geometry, respectively. It is found that circular-depolarization obtained from these 2 methods is very similar in both geometries, and that linear-retardance is highly quantitatively similar for transmission geometry and qualitatively similar for reflection geometry. The majority of tissue circular-depolarization and linear-retardance image information (represented by local image contrast features) obtained from Mueller polarimetry is well preserved from Stokes polarimetry in both geometries. These findings can be referred to for further understanding tissue Stokes polarimetric data, and for further application of Stokes polarimetry under the circumstances where short acquisition time or low optical system complexity is a priority, such as polarimetric endoscopy and microscopy.
Collapse
Affiliation(s)
- Ji Qi
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, London, UK
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Honghui He
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Physics, Tsinghua University, Beijing, China
| | - Jianyu Lin
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, London, UK
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Yang Dong
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Physics, Tsinghua University, Beijing, China
| | - Dongsheng Chen
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Physics, Tsinghua University, Beijing, China
| | - Hui Ma
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, China
- Department of Physics, Tsinghua University, Beijing, China
- Center for Precision Medicine and Healthcare, Tsinghua-Berkeley Shenzhen Institute, Shenzhen, China
| | - Daniel S Elson
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, London, UK
- Department of Surgery and Cancer, Imperial College London, London, UK
| |
Collapse
|
41
|
Cha J, Broch A, Mudge S, Kim K, Namgoong JM, Oh E, Kim P. Real-time, label-free, intraoperative visualization of peripheral nerves and micro-vasculatures using multimodal optical imaging techniques. BIOMEDICAL OPTICS EXPRESS 2018; 9. [PMID: 29541506 PMCID: PMC5846516 DOI: 10.1364/boe.9.001097] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Accurate, real-time identification and display of critical anatomic structures, such as the nerve and vasculature structures, are critical for reducing complications and improving surgical outcomes. Human vision is frequently limited in clearly distinguishing and contrasting these structures. We present a novel imaging system, which enables noninvasive visualization of critical anatomic structures during surgical dissection. Peripheral nerves are visualized by a snapshot polarimetry that calculates the anisotropic optical properties. Vascular structures, both venous and arterial, are identified and monitored in real-time using a near-infrared laser-speckle-contrast imaging. We evaluate the system by performing in vivo animal studies with qualitative comparison by contrast-agent-aided fluorescence imaging.
Collapse
Affiliation(s)
- Jaepyeong Cha
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
- These authors contributed equally to this work
| | - Aline Broch
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
- These authors contributed equally to this work
| | - Scott Mudge
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
| | - Kihoon Kim
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
- Department of Surgery, Inje University Haeundae Paik Hospital, 875 Haeun-daero, Haeundae-gu, Busan 612-896, South Korea
| | - Jung-Man Namgoong
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
- Department of Surgery, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 138-736, South Korea
| | - Eugene Oh
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
- Department of Biomedical Engineering, The Johns Hopkins University, 3400 N. Charles Street, Baltimore, MD 21218, USA
| | - Peter Kim
- Sheikh Zyaed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Avenue NW, Washington, DC 20010, USA
| |
Collapse
|
42
|
Qi J, He C, Elson DS. Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging. BIOMEDICAL OPTICS EXPRESS 2017; 8:4933-4946. [PMID: 29188092 PMCID: PMC5695942 DOI: 10.1364/boe.8.004933] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Revised: 10/03/2017] [Accepted: 10/03/2017] [Indexed: 05/03/2023]
Abstract
Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled.
Collapse
Affiliation(s)
- Ji Qi
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| | - Chao He
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| | - Daniel S. Elson
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London SW7 2AZ, UK
| |
Collapse
|
43
|
Dong Y, He H, Sheng W, Wu J, Ma H. A quantitative and non-contact technique to characterise microstructural variations of skin tissues during photo-damaging process based on Mueller matrix polarimetry. Sci Rep 2017; 7:14702. [PMID: 29089638 PMCID: PMC5666003 DOI: 10.1038/s41598-017-14804-z] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 10/17/2017] [Indexed: 12/11/2022] Open
Abstract
Skin tissue consists of collagen and elastic fibres, which are highly susceptible to damage when exposed to ultraviolet radiation (UVR), leading to skin aging and cancer. However, a lack of non-invasive detection methods makes determining the degree of UVR damage to skin in real time difficult. As one of the fundamental features of light, polarization can be used to develop imaging techniques capable of providing structural information about tissues. In particular, Mueller matrix polarimetry is suitable for detecting changes in collagen and elastic fibres. Here, we demonstrate a novel, quantitative, non-contact and in situ technique based on Mueller matrix polarimetry for monitoring the microstructural changes of skin tissues during UVR-induced photo-damaging. We measured the Mueller matrices of nude mouse skin samples, then analysed the transformed parameters to characterise microstructural changes during the skin photo-damaging and self-repairing processes. Comparisons between samples with and without the application of a sunscreen showed that the Mueller matrix-derived parameters are potential indicators for fibrous microstructure in skin tissues. Histological examination and Monte Carlo simulations confirmed the relationship between the Mueller matrix parameters and changes to fibrous structures. This technique paves the way for non-contact evaluation of skin structure in cosmetics and dermatological health.
Collapse
Affiliation(s)
- Yang Dong
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China.,Department of Biomedical Engineering, Tsinghua University, Beijing, 100084, China
| | - Honghui He
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Wei Sheng
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China.,Department of Biomedical Engineering, Tsinghua University, Beijing, 100084, China
| | - Jian Wu
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Hui Ma
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China. .,Center for Precision Medicine and Healthcare, Tsinghua-Berkeley Shenzhen Institute, Shenzhen, 518071, China. .,Department of Physics, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
44
|
Qi J, He H, Ma H, Elson DS. Extended polar decomposition method of Mueller matrices for turbid media in reflection geometry. OPTICS LETTERS 2017; 42:4048-4051. [PMID: 29028009 DOI: 10.1364/ol.42.004048] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Accepted: 09/03/2017] [Indexed: 05/25/2023]
Abstract
The polar decomposition method for Mueller matrices proposed by Lu-Chipman has been demonstrated and validated for many applications. However, in some situations, e.g., when analyzing the Mueller matrix of birefringent turbid media with Mie-sized scatterers acquired in reflection geometry, the method may suffer from limitations due to the assumptions required by this method. Here we extend the Lu-Chipman method and show that it can provide more reasonable results for these situations. The method has been validated experimentally with turbid phantoms. Thus, this Letter may prove useful in tissue polarimetry.
Collapse
|
45
|
Flexible polarimetric probe for 3 × 3 Mueller matrix measurements of biological tissue. Sci Rep 2017; 7:11958. [PMID: 28931853 PMCID: PMC5607295 DOI: 10.1038/s41598-017-12099-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 09/04/2017] [Indexed: 12/20/2022] Open
Abstract
Polarimetry is a noninvasive method that uses polarised light to assess biophysical characteristics of tissues. A series of incident polarisation states illuminates a biological sample, and analysis of sample-altered polarisation states enables polarimetric tissue assessment. The resultant information can, for example, help quantitatively differentiate healthy from pathologic tissue. However, most bio-polarimetric assessments are performed using free-space optics with bulky optical components. Extension to flexible fibre-based systems is clinically desirable, but is challenging due to polarisation-altering properties of optical fibres. Here, we propose a flexible fibre-based polarimetric solution, and describe its design, fabrication, calibration, and initial feasibility demonstration in ex vivo tissue. The design is based on a flexible fibre bundle of six multimode optical fibres, each terminated with a distal polariser that ensures pre-determined output polarisation states. The resultant probe enables linear 3 × 3 Mueller matrix characterization of distal tissue. Potential in vivo Mueller matrix polarimetric tissue examinations in various directly-inaccessible body cavities are envisioned.
Collapse
|
46
|
Dong Y, Qi J, He H, He C, Liu S, Wu J, Elson DS, Ma H. Quantitatively characterizing the microstructural features of breast ductal carcinoma tissues in different progression stages by Mueller matrix microscope. BIOMEDICAL OPTICS EXPRESS 2017; 8:3643-3655. [PMID: 28856041 PMCID: PMC5560831 DOI: 10.1364/boe.8.003643] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 07/09/2017] [Accepted: 07/10/2017] [Indexed: 05/02/2023]
Abstract
Polarization imaging has been recognized as a potentially powerful technique for probing the microstructural information and optical properties of complex biological specimens. Recently, we have reported a Mueller matrix microscope by adding the polarization state generator and analyzer (PSG and PSA) to a commercial transmission-light microscope, and applied it to differentiate human liver and cervical cancerous tissues with fibrosis. In this paper, we apply the Mueller matrix microscope for quantitative detection of human breast ductal carcinoma samples at different stages. The Mueller matrix polar decomposition and transformation parameters of the breast ductal tissues in different regions and at different stages are calculated and analyzed. For more quantitative comparisons, several widely-used image texture feature parameters are also calculated to characterize the difference in the polarimetric images. The experimental results indicate that the Mueller matrix microscope and the polarization parameters can facilitate the quantitative detection of breast ductal carcinoma tissues at different stages.
Collapse
Affiliation(s)
- Yang Dong
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
- Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China
- These authors contributed equally to this work
| | - Ji Qi
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- These authors contributed equally to this work
| | - Honghui He
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Chao He
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| | - Shaoxiong Liu
- Shenzhen Sixth People's Hospital (Nanshan Hospital) Huazhong University of Science and Technology Union Shenzhen Hospital, Shenzhen 518052, China
| | - Jian Wu
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Daniel S Elson
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| | - Hui Ma
- Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
- Center for Precision Medicine and Healthcare, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518071, China
- Department of Physics, Tsinghua University, Beijing 100084, China
| |
Collapse
|
47
|
Qi J, Elson DS. Mueller polarimetric imaging for surgical and diagnostic applications: a review. JOURNAL OF BIOPHOTONICS 2017; 10:950-982. [PMID: 28464464 DOI: 10.1002/jbio.201600152] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Revised: 01/18/2017] [Accepted: 01/19/2017] [Indexed: 05/02/2023]
Abstract
Polarization is a fundamental property of light and a powerful sensing tool that has been applied to many areas. A Mueller matrix is a complete mathematical description of the polarization characteristics of objects that interact with light, and is known as a transfer function of Stokes vectors which characterise the state of polarization of light. Mueller polarimetric imaging measures Mueller matrices over a field of view and thus allows for visualising the polarization characteristics of the objects. It has emerged as a promising technique in recent years for tissue imaging, improving image contrast and providing a unique perspective to reveal additional information that cannot be resolved by other optical imaging modalities. This review introduces the basis of the Stokes-Mueller formulism, interpretation methods of Mueller matrices into fundamental polarization properties, polarization properties of biological tissues, and considerations in the construction of Mueller polarimetric imaging devices for surgical and diagnostic applications, including primary configurations, optimization procedures, calibration methods as well as the instrument polarization properties of several widely-used biomedical optical devices. The paper also reviews recent progress in Mueller polarimetric endoscopes and fibre Mueller polarimeters, followed by the future outlook in applying the technique to surgery and diagnostics. Tissue polarization properties convey morphological, micro-structural and compositional information of tissue with great potential for label free characterization of tissue pathological changes. Recent progress in tissue polarimetric imaging and polarization resolved endoscopy paved the way for translation of polarimetric imaging to surgery and tissue diagnosis.
Collapse
Affiliation(s)
- Ji Qi
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| | - Daniel S Elson
- Hamlyn Centre for Robotic Surgery, Institute of Global Health Innovation, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
- Department of Surgery and Cancer, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| |
Collapse
|
48
|
In vivo imaging of uterine cervix with a Mueller polarimetric colposcope. Sci Rep 2017; 7:2471. [PMID: 28572602 PMCID: PMC5453972 DOI: 10.1038/s41598-017-02645-9] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Accepted: 04/26/2017] [Indexed: 11/08/2022] Open
Abstract
Mueller polarimetric imaging enables the detection and quantification of modifications of the collagen fibers in the uterine cervix due to the development of a precancerous lesion. This information is not accessible through the use of the classic colposcope, a low magnification microscope used in current practice for cervical cancer screening. However, the in vivo application of Mueller polarimetric imaging poses an instrumental challenge: the device should be sufficiently compact, while still being able to perform fast and accurate acquisition of Mueller matrices in real-world conditions. In this study, the first wide field Mueller Polarimetric Colposcope (MPC) for the in vivo analysis of uterine cervix is presented. The MPC has been fabricated by grafting a miniaturized Mueller polarimetric imager on a classic colposcope. This new imaging tool performs the fast acquisition of Mueller polarimetric images, thus eliminating any blurring effects due to patient movements. It can be easily used by a practitioner with little change to their existing practice. Finally, the MPC was tested in vivo on a number of patients in the field.
Collapse
|
49
|
Novikova T. Optical techniques for cervical neoplasia detection. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2017; 8:1844-1862. [PMID: 29046833 PMCID: PMC5629403 DOI: 10.3762/bjnano.8.186] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Accepted: 08/09/2017] [Indexed: 05/04/2023]
Abstract
This paper provides an overview of the current research in the field of optical techniques for cervical neoplasia detection and covers a wide range of the existing and emerging technologies. Using colposcopy, a visual inspection of the uterine cervix with a colposcope (a binocular microscope with 3- to 15-fold magnification), has proven to be an efficient approach for the detection of invasive cancer. Nevertheless, the development of a reliable and cost-effective technique for the identification of precancerous lesions, confined to the epithelium (cervical intraepithelial neoplasia) still remains a challenging problem. It is known that even at early stages the neoplastic transformations of cervical tissue induce complex changes and modify both structural and biochemical properties of tissues. The different methods, including spectroscopic (diffuse reflectance spectroscopy, induced fluorescence and autofluorescence spectroscopy, Raman spectroscopy) and imaging techniques (confocal microscopy, optical coherence tomography, Mueller matrix imaging polarimetry, photoacoustic imaging), probe different tissue properties that may serve as optical biomarkers for diagnosis. Both the advantages and drawbacks of these techniques for the diagnosis of cervical precancerous lesions are discussed and compared.
Collapse
Affiliation(s)
- Tatiana Novikova
- LPICM, CNRS, Ecole polytechnique, University Paris Saclay, Palaiseau, France
| |
Collapse
|