1
|
Shao X, Huang Y, Wang G. Microfluidic devices for protein analysis using intact and top‐down mass spectrometry. VIEW 2022. [DOI: 10.1002/viw.20220032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Affiliation(s)
- Xinyang Shao
- Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
- Biomedical Pioneering Innovation Center Peking University Beijing China
- Peking‐Tsinghua Center for Life Sciences Peking University Beijing China
| | - Yanyi Huang
- Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
- Biomedical Pioneering Innovation Center Peking University Beijing China
- Peking‐Tsinghua Center for Life Sciences Peking University Beijing China
- College of Chemistry and Molecular Engineering and Beijing National Laboratory for Molecular Sciences Peking University Beijing China
| | - Guanbo Wang
- Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
- Biomedical Pioneering Innovation Center Peking University Beijing China
| |
Collapse
|
2
|
Li W, Chaihu L, Jiang J, Wu B, Zheng X, Dai R, Tian Y, Huang Y, Wang G, Men Y. Microfluidic Platform for Time-Resolved Characterization of Protein Higher-Order Structures and Dynamics Using Top-Down Mass Spectrometry. Anal Chem 2022; 94:7520-7527. [PMID: 35584038 DOI: 10.1021/acs.analchem.2c00077] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Characterization of protein higher-order structures and dynamics is essential for understanding the biological functions of proteins and revealing the underlying mechanisms. Top-down mass spectrometry (MS) accesses structural information at both the intact protein level and the peptide fragment level. Native top-down MS allows analysis of a protein complex's architecture and subunits' identity and modifications. Top-down hydrogen/deuterium exchange (HDX) MS offers high spatial resolution for conformational or binding interface analysis and enables conformer-specific characterization. A microfluidic chip can provide superior performance for front-end reactions useful for these MS workflows, such as flexibility in manipulating multiple reactant flows, integrating various functional modules, and automation. However, most microchip-MS devices are designed for bottom-up approaches or top-down proteomics. Here, we demonstrate a strategy for designing a microchip for top-down MS analysis of protein higher-order structures and dynamics. It is suitable for time-resolved native MS and HDX MS, with designs aiming for efficient ionization of intact protein complexes, flexible manipulation of multiple reactant flows, and precise control of reaction times over a broad range of flow rates on the submicroliter per minute scale. The performance of the prototype device is demonstrated by measurements of systems including monoclonal antibodies, antibody-antigen complexes, and coexisting protein conformers. This strategy may benefit elaborate structural analysis of biomacromolecules and inspire method development using the microchip-MS approach.
Collapse
Affiliation(s)
- Wen Li
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Lingxiao Chaihu
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China.,Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Jialu Jiang
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Bizhu Wu
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Xuan Zheng
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Rongrong Dai
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Ye Tian
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Yanyi Huang
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China.,Biomedical Pioneering Innovation Centre, Peking University, Beijing 100871, China
| | - Guanbo Wang
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China.,Biomedical Pioneering Innovation Centre, Peking University, Beijing 100871, China
| | - Yongfan Men
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
3
|
McCullagh M, Douce D, Van Hoeck E, Goscinny S. Exploring the Complexity of Steviol Glycosides Analysis Using Ion Mobility Mass Spectrometry. Anal Chem 2018. [DOI: 10.1021/acs.analchem.7b05002] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Michael McCullagh
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow, SK9 4AX, U.K
| | - David Douce
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow, SK9 4AX, U.K
| | - Els Van Hoeck
- Scientific Institute of Public Health, Rue Juliette Wytsmans 14, 1050 Brussels, Belgium
| | - Severine Goscinny
- Scientific Institute of Public Health, Rue Juliette Wytsmans 14, 1050 Brussels, Belgium
| |
Collapse
|
4
|
|
5
|
Chen X, Shen J, Hu Z, Huo X. Manufacturing methods and applications of membranes in microfluidics. Biomed Microdevices 2016; 18:104. [DOI: 10.1007/s10544-016-0130-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
6
|
Lotter C, Heiland JJ, Thurmann S, Mauritz L, Belder D. HPLC-MS with Glass Chips Featuring Monolithically Integrated Electrospray Emitters of Different Geometries. Anal Chem 2016; 88:2856-63. [DOI: 10.1021/acs.analchem.5b04583] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Carsten Lotter
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Josef J. Heiland
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Sebastian Thurmann
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Laura Mauritz
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| | - Detlev Belder
- Institute
of Analytical Chemistry, University of Leipzig, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
7
|
Gómez-Ríos GA, Reyes-Garcés N, Bojko B, Pawliszyn J. Biocompatible Solid-Phase Microextraction Nanoelectrospray Ionization: An Unexploited Tool in Bioanalysis. Anal Chem 2015; 88:1259-65. [DOI: 10.1021/acs.analchem.5b03668] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
| | - Nathaly Reyes-Garcés
- Department
of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Barbara Bojko
- Department
of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department
of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
8
|
Three-Dimensional Electro-Sonic Flow Focusing Ionization Microfluidic Chip for Mass Spectrometry. MICROMACHINES 2015. [DOI: 10.3390/mi6121463] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Dietze C, Scholl T, Ohla S, Appun J, Schneider C, Belder D. Rapid prototyping of microfluidic chips for dead-volume-free MS coupling. Anal Bioanal Chem 2015; 407:8735-43. [DOI: 10.1007/s00216-015-9027-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2015] [Revised: 08/20/2015] [Accepted: 09/03/2015] [Indexed: 11/30/2022]
|
10
|
Feng X, Liu BF, Li J, Liu X. Advances in coupling microfluidic chips to mass spectrometry. MASS SPECTROMETRY REVIEWS 2015; 34:535-57. [PMID: 24399782 DOI: 10.1002/mas.21417] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 11/07/2013] [Accepted: 11/07/2013] [Indexed: 05/26/2023]
Abstract
Microfluidic technology has shown advantages of low sample consumption, reduced analysis time, high throughput, and potential for integration and automation. Coupling microfluidic chips to mass spectrometry (Chip-MS) can greatly improve the overall analytical performance of MS-based approaches and expand their potential applications. In this article, we review the advances of Chip-MS in the past decade, covering innovations in microchip fabrication, microchips coupled to electrospray ionization (ESI)-MS and matrix-assisted laser desorption/ionization (MALDI)-MS. Development of integrated microfluidic systems for automated MS analysis will be further documented, as well as recent applications of Chip-MS in proteomics, metabolomics, cell analysis, and clinical diagnosis.
Collapse
MESH Headings
- Animals
- Chromatography, Liquid/instrumentation
- Chromatography, Liquid/methods
- Electrophoresis, Microchip/instrumentation
- Electrophoresis, Microchip/methods
- Equipment Design
- Humans
- Lab-On-A-Chip Devices
- Lipids/analysis
- Metabolomics/instrumentation
- Metabolomics/methods
- Polysaccharides/analysis
- Proteins/analysis
- Proteomics/instrumentation
- Proteomics/methods
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
Collapse
Affiliation(s)
- Xiaojun Feng
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Jianjun Li
- Human Health Therapeutics, National Research Council Canada, Ottawa, Ontario, Canada K1A 0R6
| | - Xin Liu
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
11
|
Gallagher R, Dillon L, Grimsley A, Murphy J, Samuelsson K, Douce D. The application of a new microfluidic device for the simultaneous identification and quantitation of midazolam metabolites obtained from a single micro-litre of chimeric mice blood. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:1293-1302. [PMID: 24760570 DOI: 10.1002/rcm.6902] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Revised: 03/12/2014] [Accepted: 03/21/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE Improvements in the design of low-flow highly sensitive chromatographic ion source interfaces allow the detection and characterisation of drugs and metabolites from smaller sample volumes. This in turn improves the ethical treatment of animals by reducing both the number of animals needed and the blood sampling volumes required. METHODS A new microfluidic device combining an ultra-high pressure liquid chromatography (UHPLC) analytical column with a nano-flow electrospray source is described. All microfluidic, gas and electrical connections are automatically engaged when the ceramic microfluidic device is inserted into the source enclosure. The system was used in conjunction with a hybrid quadrupole-time-of-flight mass spectrometer. RESULTS The improved sensitivity of the system is highlighted in its application in the quantification and qualification of midazolam and its metabolites detected in whole blood from chimeric and wild-type mice. Metabolite identification and full pharmacokinetic profiles were obtained from a single micro-litre of whole blood at each sampling time and significant pharmacokinetic differences were observed between the two types of mice. CONCLUSIONS Improvements in the enhanced ionisation efficiency from the microfluidic device in conjunction with nanoUHPLC/MS was sufficiently sensitive for the identification and quantification of midazolam metabolites from a single micro-litre of whole blood. Detection of metabolites not previously recorded from the chimeric mouse in vivo model was made.
Collapse
Affiliation(s)
- Richard Gallagher
- Oncology iMed DMPK, AstraZeneca UK Ltd., Alderley Park, Macclesfield, Cheshire, SK10 4TG, UK
| | | | | | | | | | | |
Collapse
|
12
|
He X, Chen Q, Zhang Y, Lin JM. Recent advances in microchip-mass spectrometry for biological analysis. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2013.09.013] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
13
|
Lin SL, Bai HY, Lin TY, Fuh MR. Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications. Electrophoresis 2012; 33:635-43. [PMID: 22451056 DOI: 10.1002/elps.201100380] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The development and integration of microfabricated liquid chromatography (LC) microchips have increased dramatically in the last decade due to the needs of enhanced sensitivity and rapid analysis as well as the rising concern on reducing environmental impacts of chemicals used in various types of chemical and biochemical analyses. Recent development of microfluidic chip-based LC mass spectrometry (chip-based LC-MS) has played an important role in proteomic research for high throughput analysis. To date, the use of chip-based LC-MS for determination of small molecules, such as biomarkers, active pharmaceutical ingredients (APIs), and drugs of abuse and their metabolites, in clinical and pharmaceutical applications has not been thoroughly investigated. This mini-review summarizes the utilization of commercial chip-based LC-MS systems for determination of small molecules in bioanalytical applications, including drug metabolites and disease/tumor-associated biomarkers in clinical samples as well as adsorption, distribution, metabolism, and excretion studies of APIs in drug discovery and development. The different types of commercial chip-based interfaces for LC-MS analysis are discussed first and followed by applications of chip-based LC-MS on biological samples as well as the comparison with other LC-MS techniques.
Collapse
Affiliation(s)
- Shu-Ling Lin
- Department of Chemistry, Soochow University, Taipei, Taiwan
| | | | | | | |
Collapse
|
14
|
Ohla S, Belder D. Chip-based separation devices coupled to mass spectrometry. Curr Opin Chem Biol 2012; 16:453-9. [PMID: 22673066 DOI: 10.1016/j.cbpa.2012.05.180] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Revised: 04/27/2012] [Accepted: 05/03/2012] [Indexed: 10/28/2022]
Abstract
The hyphenation of miniaturized separation techniques like chip electrophoresis or chip chromatography to mass spectrometry (MS) is a highly active research area in modern separation science. Such methods are particularly attractive for comprehensive analysis of complex biological samples. They can handle extremely low sample amounts, with low solvent consumption. Furthermore they provide unsurpassed analysis speed together with the prospect of integrating several functional elements on a single multifunctional platform. In this article we review the latest developments in this emerging field of technology and summarize recent trends to face current and future challenges in chip-based biochemical analysis.
Collapse
Affiliation(s)
- Stefan Ohla
- Institut für Analytische Chemie, Universität Leipzig, Linnéstr. 3, D-04103 Leipzig, Germany
| | | |
Collapse
|
15
|
Mao X, Reschke BR, Timperman AT. Analyte transport past a nanofluidic intermediate electrode junction in a microfluidic device. Electrophoresis 2010; 31:2686-94. [DOI: 10.1002/elps.201000068] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
16
|
Abstract
We review microfluidic devices designed for multidimensional sample analysis, with a primer on relevant theory, an emphasis on protein analysis, and an eye towards future improvements and challenges to the field. Image shows results of an on-chip IEF-CE separation of a protein mixture; unpublished surface plot data from A. E. Herr.
Collapse
Affiliation(s)
- Samuel Tia
- Department of Bioengineering, University of California, Berkeley, 308B Stanley Hall, MC # 1762 Berkeley, CA 94720-1762, USA
| | | |
Collapse
|
17
|
Hoffmann P, Eschner M, Fritzsche S, Belder D. Spray Performance of Microfluidic Glass Devices with Integrated Pulled Nanoelectrospray Emitters. Anal Chem 2009; 81:7256-61. [DOI: 10.1021/ac9015038] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Peter Hoffmann
- University of Leipzig, Institute of Analytical Chemistry, Johannisallee 29, 04103 Leipzig, Germany
| | - Markus Eschner
- University of Leipzig, Institute of Analytical Chemistry, Johannisallee 29, 04103 Leipzig, Germany
| | - Stefanie Fritzsche
- University of Leipzig, Institute of Analytical Chemistry, Johannisallee 29, 04103 Leipzig, Germany
| | - Detlev Belder
- University of Leipzig, Institute of Analytical Chemistry, Johannisallee 29, 04103 Leipzig, Germany
| |
Collapse
|
18
|
Feng X, Liu X, Luo Q, Liu BF. Mass spectrometry in systems biology: an overview. MASS SPECTROMETRY REVIEWS 2008; 27:635-660. [PMID: 18636545 DOI: 10.1002/mas.20182] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
As an emerging field, systems biology is currently the talk of the town, which challenges our philosophy in comprehending biology. Instead of the reduction approach advocated in molecular biology, systems biology aims at systems-level understanding of correlations among molecular components. Such comprehensive investigation requires massive information from the "omics" cascade demanding high-throughput screening techniques. Being one of the most versatile analytical methods, mass spectrometry has already been playing a significant role at this early stage of systems biology. In this review, we documented the advances in modern mass spectrometry technologies as well as nascent inventions. Recent applications of mass spectrometry-based techniques and methodologies in genomics, proteomics, transcriptomics and metabolomics will be further elaborated individually. Undoubtedly, more applications of mass spectrometry in systems biology can be expected in the near future.
Collapse
Affiliation(s)
- Xiaojun Feng
- The Key Laboratory of Biomedical Photonics of MOE, Department of Systems Biology, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, China
| | | | | | | |
Collapse
|
19
|
Kelly RT, Tang K, Irimia D, Toner M, Smith RD. Elastomeric microchip electrospray emitter for stable cone-jet mode operation in the nanoflow regime. Anal Chem 2008; 80:3824-31. [PMID: 18419138 PMCID: PMC2692495 DOI: 10.1021/ac8000786] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Despite widespread interest in combining laboratory-on-a-chip technologies with mass spectrometry (MS)-based analyses, the coupling of microfluidics to electrospray ionization (ESI)-MS remains challenging. We report a robust, integrated poly(dimethylsiloxane) microchip interface for ESI-MS using simple and widely accessible microfabrication procedures. The interface uses an auxiliary channel to provide electrical contact for the stable cone-jet electrospray without sample loss or dilution. The electric field at the channel terminus is enhanced by two vertical cuts that cause the interface to taper to a line rather than to a point, and the formation of a small Taylor cone at the channel exit ensures subnanoliter postcolumn dead volumes. Cone-jet mode electrospray was demonstrated for up to 90% aqueous solutions and for extended durations. Comparable ESI-MS sensitivities were achieved using both microchip and conventional fused silica capillary emitters, but stable cone-jet mode electrosprays could be established over a far broader range of flow rates (from 50-1000 nL/min) and applied potentials using the microchip emitters. This attribute of the microchip emitter should simplify electrospray optimization and make the stable electrospray more resistant to external perturbations.
Collapse
Affiliation(s)
- Ryan T Kelly
- Biological Sciences Division, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352, USA
| | | | | | | | | |
Collapse
|
20
|
Schilling M, Janasek D, Franzke J. Electrospray-ionization driven by dielectric polarization. Anal Bioanal Chem 2008; 391:555-61. [DOI: 10.1007/s00216-008-2027-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2007] [Revised: 01/31/2008] [Accepted: 02/25/2008] [Indexed: 12/01/2022]
|
21
|
Koster S, Verpoorte E. A decade of microfluidic analysis coupled with electrospray mass spectrometry: an overview. LAB ON A CHIP 2007; 7:1394-1412. [PMID: 17960264 DOI: 10.1039/b709706a] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This review presents a thorough overview covering the period 1997-2006 of microfluidic chips coupled to mass spectrometry through an electrospray interface. The different types of fabrication processes and materials used to fabricate these chips throughout this period are discussed. Three 'eras' of interfaces are clearly distinguished. The earliest approach involves spraying from the edge of a chip, while later devices either incorporate a standard fused-silica emitter inserted into the device or fully integrated emitters formed during chip fabrication. A summary of microfluidic-electrospray devices for performing separations and sample pretreatment steps before sample introduction into the mass spectrometer is also presented.
Collapse
Affiliation(s)
- Sander Koster
- Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713AV Groningen, The Netherlands.
| | | |
Collapse
|
22
|
Hoffmann P, Häusig U, Schulze P, Belder D. Microfluidic glass chips with an integrated nanospray emitter for coupling to a mass spectrometer. Angew Chem Int Ed Engl 2007; 46:4913-6. [PMID: 17516595 DOI: 10.1002/anie.200605152] [Citation(s) in RCA: 94] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Peter Hoffmann
- Institut für Analytische Chemie, Chemo- und Biosensorik, Universität Regensburg, 93040 Regensburg, Germany
| | | | | | | |
Collapse
|
23
|
Haselberg R, de Jong GJ, Somsen GW. Capillary electrophoresis–mass spectrometry for the analysis of intact proteins. J Chromatogr A 2007; 1159:81-109. [PMID: 17560583 DOI: 10.1016/j.chroma.2007.05.048] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2007] [Revised: 05/01/2007] [Accepted: 05/15/2007] [Indexed: 10/23/2022]
Abstract
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.
Collapse
Affiliation(s)
- Rob Haselberg
- Department of Biomedical Analysis, Utrecht University, 3508 TB Utrecht, The Netherlands.
| | | | | |
Collapse
|
24
|
Yue GE, Roper MG, Balchunas C, Pulsipher A, Coon JJ, Shabanowitz J, Hunt DF, Landers JP, Ferrance JP. Protein digestion and phosphopeptide enrichment on a glass microchip. Anal Chim Acta 2006; 564:116-22. [PMID: 17723369 PMCID: PMC4631396 DOI: 10.1016/j.aca.2005.11.003] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Revised: 10/24/2005] [Accepted: 11/02/2005] [Indexed: 01/14/2023]
Abstract
This work describes an integrated glass microdevice for proteomics, which directly couples proteolysis with affinity selection. Initial results with standard phosphopeptide fragments from beta-casein in peptide mixtures showed selective capture of the phosphorylated fragments using immobilized metal affinity chromatography (IMAC) beads packed into a microchannel. Complete selectivity was seen with angiotensin, with capture of only the phosphorylated form. On-chip proteolysis, using immobilized trypsin beads packed into a separate channel, was directly coupled to the phosphopeptide capture and the integrated devices evaluated using beta-casein. Captured and eluted fragments were analyzed using both capillary electrophoresis (CE) and capillary liquid chromatography/mass spectrometry (cLC/MS). The results show selective capture of only phosphopeptide fragments, but incomplete digestion of the protein was apparent from multiple peaks in the CE separations. The MS analysis indicated a capture bias on the IMAC column for the tetraphosphorylated peptide fragment over the monophosphorylated fragment. Application to digestion and capture of a serum fraction showed capture of material; however, non-specific binding was evident. Additional work will be required to fully optimize this system, but this work represents a novel sample preparation method, incorporating protein digestion on-line with affinity capture for proteomic applications.
Collapse
Affiliation(s)
- Guihua Eileen Yue
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - Michael G. Roper
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - Catherine Balchunas
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - Abigail Pulsipher
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - Joshua J. Coon
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - Jeffery Shabanowitz
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - Donald F. Hunt
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| | - James P. Landers
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
- Department of Pathology, University of Virginia Health Science Center, Charlottesville, VA 22908, United States
| | - Jerome P. Ferrance
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, United States
| |
Collapse
|
25
|
Abstract
This review article with 304 references describes recent developments in CE of proteins, and covers the two years since the previous review (Hutterer, K., Dolník, V., Electrophoresis 2003, 24, 3998-4012) through Spring 2005. It covers topics related to CE of proteins, including modeling of the electrophoretic migration of proteins, sample pretreatment, wall coatings, improving separation, various forms of detection, special electrophoretic techniques such as affinity CE, CIEF, and applications of CE to the analysis of proteins in real-world samples including human body fluids, food and agricultural samples, protein pharmaceuticals, and recombinant protein preparations.
Collapse
|
26
|
Iannacone JM, Jakubowski JA, Bohn PW, Sweedler JV. A multilayer poly(dimethylsiloxane) electrospray ionization emitter for sample injection and online mass spectrometric detection. Electrophoresis 2005; 26:4684-90. [PMID: 16278909 DOI: 10.1002/elps.200500498] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
An ESI emitter made of poly(dimethylsiloxane) interfaces on-chip sample preparation with MS detection. The unique multilayer design allows both the analyte and the spray solutions to reside on the device simultaneously in discrete microfluidic environments that are spatially separated by a polycarbonate track-etched, nanocapillary array membrane (NCAM). In direct spray mode, voltage is applied to the microchannel containing a spray solution delivered via a syringe pump. For injection, the spray potential is lowered and a voltage is applied that forward biases the membrane and permits the analyte to enter the spray channel. Once the injection is complete, the bias potential is switched off, and the spray voltage is increased to generate the ESI of the injected analyte plug. Consecutive injections of a 10 microM bovine insulin solution are reproducible and produce sample plugs with limited band broadening and high quality mass spectra. Peptide signals are observed following transport through the NCAM, even when the peptide is dissolved in solutions containing up to 20% seawater. The multilayer emitter shows great potential for performing multidimensional chemical manipulations on-chip, followed by direct ESI with negligible dead volume for online MS analysis.
Collapse
Affiliation(s)
- Jamie M Iannacone
- Department of Chemistry and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | | | | | | |
Collapse
|