1
|
Mercer C, Bennett R, Conghaile PÓ, Rusling JF, Leech D. Glucose biosensor based on open-source wireless microfluidic potentiostat. SENSORS AND ACTUATORS. B, CHEMICAL 2019; 290:616-624. [PMID: 32395016 PMCID: PMC7213535 DOI: 10.1016/j.snb.2019.02.031] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Wireless potentiostats capable of cyclic voltammetry and amperometry that connect to the Internet are emerging as key attributes of future point-of-care devices. This work presents an "integrated microfluidic electrochemical detector" (iMED) three-electrode multi-potentiostat designed around operational amplifiers connected to a powerful WiFi-based microcontroller as a promising alternative to more expensive and complex strategies reported in the literature. The iMED is integrated with a microfluidic system developed to be controlled by the same microcontroller. The iMED is programmed wirelessly over a standard WiFi network and all electrochemical data is uploaded to an open-source cloud-based server. A wired desktop computer is not necessary for operation or program uploading. This method of integrated microfluidic automation is simple, uses common and inexpensive materials, and is compatible with commercial sample injectors. An integrated biosensor platform contains four screen-printed carbon arrays inside 4 separate microfluidic detection chambers with Pt counter and pseudo Ag/AgCl reference electrodes in situ. The iMED is benchmarked with K3[Fe(CN)6] against a commercial potentiostat and then as a glucose biosensor using glucose-oxidising films of [Os(2,2'-bipyridine)2(polyvinylimidazole)10Cl] prepared on screen-printed electrodes with multi walled carbon nanotubes, poly(ethylene glycol) diglycidyl ether and flavin adenine dinucleotide-dependent glucose dehydrogenase. Potential application of this cost-effective wireless potentiostat approach to modern bioelectronics and point-of-care diagnosis is demonstrated by production of glucose oxidation currents, under pseudo-physiological conditions, using mediating films with lower redox potentials.
Collapse
Affiliation(s)
- Conan Mercer
- School of Chemistry and Ryan Institute, National University of Ireland Galway, University Road, Galway, Ireland
| | - Richard Bennett
- School of Chemistry and Ryan Institute, National University of Ireland Galway, University Road, Galway, Ireland
| | - Peter Ó. Conghaile
- National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - James F. Rusling
- School of Chemistry and Ryan Institute, National University of Ireland Galway, University Road, Galway, Ireland
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269-3136, United States
- Department of Surgery and Neag Cancer Centre, UConn Health, Farmington, CT 06030, United States
| | - Dónal Leech
- School of Chemistry and Ryan Institute, National University of Ireland Galway, University Road, Galway, Ireland
| |
Collapse
|
2
|
Bist I, Bhakta S, Jiang D, Keyes TE, Martin A, Forster RJ, Rusling JF. Evaluating Metabolite-Related DNA Oxidation and Adduct Damage from Aryl Amines Using a Microfluidic ECL Array. Anal Chem 2017; 89:12441-12449. [PMID: 29083162 PMCID: PMC5777145 DOI: 10.1021/acs.analchem.7b03528] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Damage to DNA from the metabolites of drugs and pollutants constitutes a major human toxicity pathway known as genotoxicity. Metabolites can react with metal ions and NADPH to oxidize DNA or participate in SN2 reactions to form covalently linked adducts with DNA bases. Guanines are the main DNA oxidation sites, and 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) is the initial product. Here we describe a novel electrochemiluminescent (ECL) microwell array that produces metabolites from test compounds and measures relative rates of DNA oxidation and DNA adduct damage. In this new array, films of DNA, metabolic enzymes, and an ECL metallopolymer or complex assembled in microwells on a pyrolytic graphite wafer are housed in dual microfluidic chambers. As reactant solution passes over the wells, metabolites form and can react with DNA in the films to form DNA adducts. These adducts are detected by ECL from a RuPVP polymer that uses DNA as a coreactant. Aryl amines also combine with Cu2+ and NADPH to form reactive oxygen species (ROS) that oxidize DNA. The resulting 8-oxodG was detected selectively by ECL-generating bis(2,2'-bipyridine)-(4-(1,10-phenanthrolin-6-yl)-benzoic acid)Os(II). DNA/enzyme films on magnetic beads were oxidized similarly, and 8-oxodG determined by LC/MS/MS enabled array standardization. The array limit of detection for oxidation was 720 8-oxodG per 106 nucleobases. For a series of aryl amines, metabolite-generated DNA oxidation and adduct formation turnover rates from the array correlated very well with rodent 1/TD50 and Comet assay results.
Collapse
Affiliation(s)
- Itti Bist
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Snehasis Bhakta
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Di Jiang
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Tia E. Keyes
- School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Aaron Martin
- School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Robert J. Forster
- School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
- School of Chemistry, National University of Ireland, Galway, University Road, Galway H91 TK33, Ireland
| |
Collapse
|
3
|
Uliana CV, Peverari CR, Afonso AS, Cominetti MR, Faria RC. Fully disposable microfluidic electrochemical device for detection of estrogen receptor alpha breast cancer biomarker. Biosens Bioelectron 2017; 99:156-162. [PMID: 28755608 DOI: 10.1016/j.bios.2017.07.043] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 07/05/2017] [Accepted: 07/16/2017] [Indexed: 02/08/2023]
Abstract
A novel fully disposable microfluidic electrochemical array device (µFED) was developed and successfully applied for detection of the biomarker estrogen receptor alpha (ERα). The µFED was constructed using low-cost materials and an inexpensive home cutter printer enabled the manufacture of dozens of µFEDs in less than 2h, at a cost of less than US$ 0.20 in material per device. The µFED incorporates counter and reference electrodes and eight carbon-based working electrodes, which were modified with DNA sequences known as estrogen response elements (DNA-ERE), where ERα binds specifically. Paramagnetic particles heavily decorated with anti-ERα antibody and horseradish peroxidase (MP-Ab-HRP) were used to efficiently capture ERα from the sample solution. The ERα-MP-Ab-HRP bioconjugate formed was injected into the µFED and incubated with the DNA-ERE-modified electrodes, followed by amperometric detection with application of -0.2V vs. Ag|AgCl while a mixture of H2O2 and hydroquinone was injected into the microfluidic device. An ultralow limit of detection of 10.0 fg mL-1 was obtained with the proposed method. The performance of the assay, in terms of sensitivity and reproducibility, was studied using undiluted calf serum, and excellent recoveries in the range of 94.7-108% were achieved for the detection of ERα in MCF-7 cell lysate. The µFED system can be easily constructed and applied for multiplex biomarker detection, making the device an excellent cost-effective alternative for cancer diagnosis, especially in developing countries.
Collapse
Affiliation(s)
- Carolina V Uliana
- Department of Chemistry, Federal University of São Carlos, São Carlos 13565-905, SP, Brazil
| | - Camila R Peverari
- Department of Chemistry, Federal University of São Carlos, São Carlos 13565-905, SP, Brazil
| | - André S Afonso
- Institute of Science, Engineering and Technology, UFVJM, Teófilo Otoni 39803-371, MG, Brazil
| | - Marcia R Cominetti
- Department of Gerontology, Federal University of São Carlos, São Carlos 13565-905, SP, Brazil
| | - Ronaldo C Faria
- Department of Chemistry, Federal University of São Carlos, São Carlos 13565-905, SP, Brazil.
| |
Collapse
|
4
|
Hvastkovs EG, Rusling JF. Modern Approaches to Chemical Toxicity Screening. CURRENT OPINION IN ELECTROCHEMISTRY 2017; 3:18-22. [PMID: 29250606 PMCID: PMC5729768 DOI: 10.1016/j.coelec.2017.03.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Chemical toxicity has a serious impact on public health, and toxicity failures of drug candidates drive up drug development costs. Many in vitro bioassays exist for toxicity screening, and newer versions of these tend to be high throughput or high content assays, some of which rely on electrochemical detection. Toxicity very often results from metabolites of the chemicals we are exposed to, so it is important that assays feature metabolic conversion. Combining bioassays, computational predictions, and accurate chemical pathway elucidation presents our best chance for reliable toxicity prediction. Employing electrochemical and electrochemiluminescent approaches, cell-free microfluidic arrays can measure relative rates of formation of DNA-metabolite adduct formation (a measure of genotoxicity) as well as DNA oxidation levels resulting from enzyme-generated metabolites. Enzymes for several organ types can be studied simultaneously. These arrays can be used to identify the most reactive metabolites, and subsequent mechanistic details can then be investigated with high throughput LC-HPLC using enzyme/DNA-coated magnetic beads.
Collapse
Affiliation(s)
- Eli G Hvastkovs
- Department of Chemistry, East Carolina University, Greenville, NC 27858, USA
| | - James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA
- Institute of Material Science, University of Connecticut, Storrs, CT 06269, USA
- Department of Surgery and Neag Cancer Center, University of Connecticut Health Center, Farmington, CT 06032, USA
- School of Chemistry, National University of Ireland at Galway, Ireland
| |
Collapse
|
5
|
Kadimisetty K, Malla S, Rusling JF. Automated 3-D Printed Arrays to Evaluate Genotoxic Chemistry: E-Cigarettes and Water Samples. ACS Sens 2017; 2:670-678. [PMID: 28723166 DOI: 10.1021/acssensors.7b00118] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
A novel, automated, low cost, three-dimensional (3-D) printed microfluidic array was developed to detect DNA damage from metabolites of chemicals in environmental samples. The electrochemiluminescent (ECL) detection platform incorporates layer-by-layer (LbL) assembled films of microsomal enzymes, DNA and an ECL-emitting ruthenium metallopolymer in ∼10 nm deep microwells. Liquid samples are introduced into the array, metabolized by the human enzymes, products react with DNA if possible, and DNA damage is detected by ECL with a camera. Measurements of relative DNA damage by the array assess the genotoxic potential of the samples. The array analyzes three samples simultaneously in 5 min. Measurement of cigarette and e-cigarette smoke extracts and polluted water samples was used to establish proof of concept. Potentially genotoxic reactions from e-cigarette vapor similar to smoke from conventional cigarettes were demonstrated. Untreated wastewater showed a high genotoxic potential compared to negligible values for treated wastewater from a pollution control treatment plant. Reactivity of chemicals known to produce high rates of metabolite-related DNA damage were measured, and array results for environmental samples were expressed in terms of equivalent responses from these standards to assess severity of possible DNA damage. Genotoxic assessment of wastewater samples during processing also highlighted future on-site monitoring applications.
Collapse
Affiliation(s)
- Karteek Kadimisetty
- Department
of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Spundana Malla
- Department
of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - James F. Rusling
- Department
of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Institute of Material Science, Storrs, Connecticut 06269, United States
- Department
of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
- School
of Chemistry, National University of Ireland at Galway, Galaway, Ireland
| |
Collapse
|
6
|
Dashti H, Westler WM, Markley JL, Eghbalnia HR. Unique identifiers for small molecules enable rigorous labeling of their atoms. Sci Data 2017; 4:170073. [PMID: 28534867 PMCID: PMC5441290 DOI: 10.1038/sdata.2017.73] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 04/28/2017] [Indexed: 11/09/2022] Open
Abstract
Rigorous characterization of small organic molecules in terms of their structural and biological properties is vital to biomedical research. The three-dimensional structure of a molecule, its 'photo ID', is inefficient for searching and matching tasks. Instead, identifiers play a key role in accessing compound data. Unique and reproducible molecule and atom identifiers are required to ensure the correct cross-referencing of properties associated with compounds archived in databases. The best approach to this requirement is the International Chemical Identifier (InChI). However, the current implementation of InChI fails to provide a complete standard for atom nomenclature, and incorrect use of the InChI standard has resulted in the proliferation of non-unique identifiers. We propose a methodology and associated software tools, named ALATIS, that overcomes these shortcomings. ALATIS is an adaptation of InChI, which operates fully within the InChI convention to provide unique and reproducible molecule and all atom identifiers. ALATIS includes an InChI extension for unique atom labeling of symmetric molecules. ALATIS forms the basis for improving reproducibility and unifying cross-referencing across databases.
Collapse
Affiliation(s)
- Hesam Dashti
- National Magnetic Resonance Facility at Madison, Department of Biochemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - William M Westler
- National Magnetic Resonance Facility at Madison, Department of Biochemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - John L Markley
- National Magnetic Resonance Facility at Madison, Department of Biochemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - Hamid R Eghbalnia
- National Magnetic Resonance Facility at Madison, Department of Biochemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| |
Collapse
|
7
|
Song B, Shen M, Jiang D, Malla S, Mosa IM, Choudhary D, Rusling JF. Microfluidic array for simultaneous detection of DNA oxidation and DNA-adduct damage. Analyst 2016; 141:5722-5729. [PMID: 27517117 PMCID: PMC5048564 DOI: 10.1039/c6an01237j] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Exposure to chemical pollutants and pharmaceuticals may cause health issues caused by metabolite-related toxicity. This paper reports a new microfluidic electrochemical sensor array with the ability to simultaneously detect common types of DNA damage including oxidation and nucleobase adduct formation. Sensors in the 8-electrode screen-printed carbon array were coated with thin films of metallopolymers osmium or ruthenium bipyridyl-poly(vinylpyridine) chloride (OsPVP, RuPVP) along with DNA and metabolic enzymes by layer-by-layer electrostatic assembly. After a reaction step in which test chemicals and other necessary reagents flow over the array, OsPVP selectively detects oxidized guanines on the DNA strands, and RuPVP detects DNA adduction by metabolites on nucleobases. We demonstrate array performance for test chemicals including 17β-estradiol (E2), its metabolites 4-hydroxyestradiol (4-OHE2), 2-hydroxyestradiol (2-OHE2), catechol, 2-nitrosotoluene (2-NO-T), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), and 2-acetylaminofluorene (2-AAF). Results revealed DNA-adduct and oxidation damage in a single run to provide a metabolic-genotoxic chemistry screen. The array measures damage directly in unhydrolyzed DNA, and is less expensive, faster, and simpler than conventional methods to detect DNA damage. The detection limit for oxidation is 672 8-oxodG per 106 bases. Each sensor requires only 22 ng of DNA, so the mass detection limit is 15 pg (∼10 pmol) 8-oxodG.
Collapse
Affiliation(s)
- Boya Song
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.
| | | | | | | | | | | | | |
Collapse
|
8
|
Bano K, Rusling JF. Electrochemiluminescence Arrays for Studies of Metabolite-related Toxicity. ELECTROANAL 2016; 28:2636-2643. [PMID: 28592918 DOI: 10.1002/elan.201600207] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
This article reviews recent progress from our laboratory in electrochemiluminescence (ECL) arrays designed for screening toxicity-related chemistry of chemical and drug candidates. Cytochrome P450s and metabolic bioconjugation enzymes convert lipophilic chemicals in our bodies by oxidation and bioconjugation that can lead to toxic metabolites. DNA can be used as an easily measurable toxicity-related endpoint, targeting DNA oxidation and addcut formation with metabolites. ECL using guanosines in the DNA strands as co-reactants have been used in high throughput arrays utilizing DNA-enzyme films fabricated layer-by-layer. This review describes approaches developed to provide new high throughput ECL arrays to aid in toxicity assessment for drug and chemical product development.
Collapse
Affiliation(s)
- Kiran Bano
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA
| | - James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.,Department of Surgery and Neag Cancer Center, University of Connecticut Health Center, Farmington, CT 06032, USA.,Institute of Material Science, University of Connecticut, Storrs, CT 06269, USA.,School of Chemistry, NationalUniversity of Ireland at Galway, Ireland
| |
Collapse
|
9
|
Abstract
Routine in vitro bioassays and animal toxicity studies of drug and environmental chemical candidates fail to reveal toxicity in ∼30% of cases. This Feature article addresses research on new approaches to in vitro toxicity testing as well as our own efforts to produce high-throughput genotoxicity arrays and LC-MS/MS approaches to reveal possible chemical pathways of toxicity.
Collapse
Affiliation(s)
- Eli G. Hvastkovs
- Department of Chemistry, East Carolina University Greenville, North Carolina 27858, United States
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Surgery and Neag Cancer Center, University of Connecticut Health Center, Farmington, Connecticut 06032, United States
- Institute of Material Science, University of Connecticut, Storrs, Connecticut 06269, United States
- School of Chemistry, National University of Ireland at Galway, Galway, Ireland
| |
Collapse
|
10
|
Wasalathanthri DP, Malla S, Bist I, Tang CK, Faria RC, Rusling JF. High-throughput metabolic genotoxicity screening with a fluidic microwell chip and electrochemiluminescence. LAB ON A CHIP 2013; 13:4554-62. [PMID: 24113555 PMCID: PMC3901045 DOI: 10.1039/c3lc50698c] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
A high throughput electrochemiluminescent (ECL) chip was fabricated and integrated into a fluidic system for screening toxicity-related chemistry of drug and pollutant metabolites. The chip base is conductive pyrolytic graphite onto which are printed 64 microwells capable of holding one-μL droplets. Films combining DNA, metabolic enzymes and an ECL-generating ruthenium metallopolymer (Ru(II)PVP) are fabricated in these microwells. The system runs metabolic enzyme reactions, and subsequently detects DNA damage caused by reactive metabolites. The performance of the chip was tested by measuring DNA damage caused by metabolites of the well-known procarcinogen benzo[a]pyrene (B[a]P). Liver microsomes and cytochrome P450 (cyt P450) enzymes were used with and without epoxide hydrolase (EH), a conjugative enzyme required for multi-enzyme bioactivation of B[a]P. DNA adduct formation was confirmed by determining specific DNA-metabolite adducts using similar films of DNA/enzyme on magnetic bead biocolloid reactors, hydrolyzing the DNA, and analyzing by capillary liquid chromatography-mass spectrometry (CapLC-MS/MS). The fluidic chip was also used to measure IC50-values of inhibitors of cyt P450s. All results show good correlation with reported enzyme activity and inhibition assays.
Collapse
|
11
|
Song B, Pan S, Tang C, Li D, Rusling JF. Voltammetric microwell array for oxidized guanosine in intact ds-DNA. Anal Chem 2013; 85:11061-7. [PMID: 24164630 PMCID: PMC3856883 DOI: 10.1021/ac402736q] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Oxidative stress in humans causes damage to biomolecules by generating reactive oxygen species (ROS). DNA can be oxidatively damaged by ROS, which may lead to carcinogenesis. Here we report a microfluidic electrochemical array designed to rapidly detect oxidation in intact DNA in replicate measurements. Sensor arrays were fabricated by wet-chemistry patterning of gold compact discs. The eight-sensor array is incorporated into a 60 μL microfluidic channel connected to a pump and sample valve. The array features 7 nm thick osmium bipyridyl poly(vinylpyridine) chloride [Os(bpy)2(PVP)10Cl](+) films assembled layer-by-layer with polyions onto the gold sensors. 8-Hydroxy-7,8-hydro-2'-deoxyguanosine (8-oxodG) is selectively oxidized by [Os(bpy)2(PVP)10Cl](+) in intact ds-DNA to provide catalytic square wave voltammograms (SWV). The device is easy-to-use, fast, inexpensive, reusable, and can detect one 8-oxodG per 6600 nucleobases. The mass detection limit is 150-fold lower than a previously reported dip-and-read voltammetric sensor for oxidized DNA. Fast assays (<1 min) and moderate sample consumption (15 pmol DNA) suggest potential for research and clinical applications. Practical use is illustrated by detecting DNA oxidation from cigarette smoke and ash extracts in dispersions with NADPH and Cu(2+).
Collapse
Affiliation(s)
- Boya Song
- Department of Chemistry, University of Connecticut , Storrs, CT 06269, United States
| | | | | | | | | |
Collapse
|
12
|
Rusling JF. Multiplexed electrochemical protein detection and translation to personalized cancer diagnostics. Anal Chem 2013; 85:5304-10. [PMID: 23635325 PMCID: PMC3674208 DOI: 10.1021/ac401058v] [Citation(s) in RCA: 103] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Measuring diagnostic panels of multiple proteins promises a new, personalized approach to early detection and therapy of diseases like cancer. Levels of biomarker proteins in patient serum can provide a continually updated record of disease status. Research in electrochemical detection of proteins has produced exquisitely sensitive approaches. Most utilize ELISA-like sandwich immunoassays incorporating various aspects of nanotechnology. Several of these ultrasensitive methodologies have been extended to microfluidic multiplexed protein detection, but engineered solutions are needed to measure more proteins in a single device from a small patient sample such as a drop of blood or tissue lysate. To achieve clinical or point-of-care (POC) use, simplicity and low cost are essential. In multiplexed microfluidic immunoassays, required reagent additions and washing steps pose a significant problem calling for creative engineering. A grand challenge is to develop a general cancer screening device to accurately measure 50-100 proteins in a simple, cost-effective fashion. This will require creative solutions to simplified reagent addition and multiplexing.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry (U-3060), University of Connecticut, 55 North Eagleville Road, Storrs, CT 06269, USA.
| |
Collapse
|
13
|
Wasalathanthri DP, Malla S, Faria RC, Rusling JF. Electrochemical Activation of the Natural Catalytic Cycle of Cytochrome P450s in Human Liver Microsomes. ELECTROANAL 2012; 24:2049-2052. [PMID: 23626453 DOI: 10.1002/elan.201200373] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The natural catalytic cycle of cytochrome (cyt) P450 enzymes in human liver microsome (HLM) films was activated electrochemically via the electron transfer sequence electrode→cyt P450 reductase (CPR)→cyt P450. Cyclic voltammograms for HLM films had midpoint potentials of -0.50 V vs. SCE at pH 7.4 characteristic of CPR, not cyt P450s. HLM and CPR microsomes without cyt P450s did not electrocatalytically reduce H2O2, and did not shift midpoint potential when CO was added, also indicating that the peaks do not correspond to iron heme cyt P450 enzymes. Electrochemical activation of the natural cyt P450 cycle for substrate conversion via CPR in HLM films was confirmed by catalytic electrolysis in an electrochemical microfluidic array designed to generate and detect reactive metabolites by measuring their reactivity with DNA.
Collapse
|