1
|
Ding S, Chen X, Yu B, Liu Z. Electrochemical biosensors for clinical detection of bacterial pathogens: advances, applications, and challenges. Chem Commun (Camb) 2024; 60:9513-9525. [PMID: 39120607 DOI: 10.1039/d4cc02272f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/10/2024]
Abstract
Bacterial pathogens are responsible for a variety of human diseases, necessitating their prompt detection for effective diagnosis and treatment of infectious diseases. Over recent years, electrochemical methods have gained significant attention owing to their exceptional sensitivity and rapidity. This review outlines the current landscape of electrochemical biosensors employed in clinical diagnostics for the detection of bacterial pathogens. We categorize these biosensors into four types: amperometry, potentiometry, electrochemical impedance spectroscopy, and conductometry, targeting various bacterial components, including toxins, virulence factors, metabolic activity, and events related to bacterial adhesion and invasion. We discuss the merits and challenges associated with electrochemical methods, underscoring their rapid response, high sensitivity, and specificity, while acknowledging the necessity for skilled operators and potential interference from biological and environmental factors. Furthermore, we examine future prospects and potential applications of electrochemical biosensors in clinical diagnostics. While electrochemical biosensors offer a promising avenue for detecting bacterial pathogens, further research in optimizing the robustness and surmounting the challenges hindering their seamless integration into clinical practice is imperative.
Collapse
Affiliation(s)
- Shengyong Ding
- Research Center of Biomedical Sensing Engineering Technology, School of Basic Medical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, China
- Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250014, People's Republic of China
| | - Xiaodi Chen
- Department of Clinical Laboratory, Jinan Maternity and Child Care Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Bin Yu
- Research Center of Biomedical Sensing Engineering Technology, School of Basic Medical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Zhiyuan Liu
- Research Center of Biomedical Sensing Engineering Technology, School of Basic Medical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, China
- Neural Engineering Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China.
| |
Collapse
|
2
|
Ozoemena OC, Boateng E, Chen A. Ultrasensitive electrochemical immunosensor for the detection of C-reactive protein antigen. Analyst 2024; 149:3773-3782. [PMID: 38845549 DOI: 10.1039/d4an00432a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/09/2024]
Abstract
Cardiovascular disease is one of the leading causes of premature death worldwide, and the determination of C-reactive protein (CRP) from human serum is of vital importance for the diagnosis of the disease. For this study, we have developed an electrochemical immunosensor based on onion-like carbon@polyacrylonitrile (OLC-PAN) for the detection of CRP antigens. This was accomplished by immobilizing CRP antibodies on a modified glassy carbon electrode (GCE). Several electrochemical techniques such as cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS) were employed to evaluate the electrochemical detection of the CRP antigen. This ultrasensitive method for CRP antigen detection exhibited a very good logarithmic plot from -4.52 to -12.05 g mL-1 and a limit of detection (LOD) of 0.9 fg mL-1. The high selectivity, sensitivity, and stability of the developed electrochemical immunosensor would facilitate miniaturization for point-of-care applications and the efficient diagnosis of cardiovascular diseases.
Collapse
Affiliation(s)
- Okoroike C Ozoemena
- Electrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2 W1, Canada.
| | - Emmanuel Boateng
- Electrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2 W1, Canada.
| | - Aicheng Chen
- Electrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2 W1, Canada.
| |
Collapse
|
3
|
Boukherroub R, Szunerits S. The Future of Nanotechnology-Driven Electrochemical and Electrical Point-of-Care Devices and Diagnostic Tests. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2024; 17:173-195. [PMID: 39018353 DOI: 10.1146/annurev-anchem-061622-012029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/19/2024]
Abstract
Point-of-care (POC) devices have become rising stars in the biosensing field, aiming at prognosis and diagnosis of diseases with a positive impact on the patient but also on healthcare and social care systems. Putting the patient at the center of interest requires the implementation of noninvasive technologies for collecting biofluids and the development of wearable platforms with integrated artificial intelligence-based tools for improved analytical accuracy and wireless readout technologies. Many electrical and electrochemical transducer technologies have been proposed for POC-based sensing, but several necessitate further development before being widely deployable. This review focuses on recent innovations in electrochemical and electrical biosensors and their growth opportunities for nanotechnology-driven multidisciplinary approaches. With a focus on analytical aspects to pave the way for future electrical/electrochemical diagnostics tests, current limitations and drawbacks as well as directions for future developments are highlighted.
Collapse
Affiliation(s)
- Rabah Boukherroub
- Université de Lille, CNRS, Université Polytechnique Hauts-de-France, UMR 8520-IEMN, Lille, France;
| | - Sabine Szunerits
- Université de Lille, CNRS, Université Polytechnique Hauts-de-France, UMR 8520-IEMN, Lille, France;
| |
Collapse
|
4
|
Li S, Zhang H, Zhu M, Kuang Z, Li X, Xu F, Miao S, Zhang Z, Lou X, Li H, Xia F. Electrochemical Biosensors for Whole Blood Analysis: Recent Progress, Challenges, and Future Perspectives. Chem Rev 2023. [PMID: 37262362 DOI: 10.1021/acs.chemrev.1c00759] [Citation(s) in RCA: 42] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Whole blood, as one of the most significant biological fluids, provides critical information for health management and disease monitoring. Over the past 10 years, advances in nanotechnology, microfluidics, and biomarker research have spurred the development of powerful miniaturized diagnostic systems for whole blood testing toward the goal of disease monitoring and treatment. Among the techniques employed for whole-blood diagnostics, electrochemical biosensors, as known to be rapid, sensitive, capable of miniaturization, reagentless and washing free, become a class of emerging technology to achieve the target detection specifically and directly in complex media, e.g., whole blood or even in the living body. Here we are aiming to provide a comprehensive review to summarize advances over the past decade in the development of electrochemical sensors for whole blood analysis. Further, we address the remaining challenges and opportunities to integrate electrochemical sensing platforms.
Collapse
Affiliation(s)
- Shaoguang Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hongyuan Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Man Zhu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zhujun Kuang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xun Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Siyuan Miao
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zishuo Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xiaoding Lou
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hui Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xia
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| |
Collapse
|
5
|
Raeisi H, Azimirad M, Asadzadeh Aghdaei H, Yadegar A, Zali MR. Rapid-format recombinant antibody-based methods for the diagnosis of Clostridioides difficile infection: Recent advances and perspectives. Front Microbiol 2022; 13:1043214. [PMID: 36523835 PMCID: PMC9744969 DOI: 10.3389/fmicb.2022.1043214] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 10/13/2022] [Indexed: 08/30/2023] Open
Abstract
Clostridioides difficile, the most common cause of nosocomial diarrhea, has been continuously reported as a worldwide problem in healthcare settings. Additionally, the emergence of hypervirulent strains of C. difficile has always been a critical concern and led to continuous efforts to develop more accurate diagnostic methods for detection of this recalcitrant pathogen. Currently, the diagnosis of C. difficile infection (CDI) is based on clinical manifestations and laboratory tests for detecting the bacterium and/or its toxins, which exhibit varied sensitivity and specificity. In this regard, development of rapid diagnostic techniques based on antibodies has demonstrated promising results in both research and clinical environments. Recently, application of recombinant antibody (rAb) technologies like phage display has provided a faster and more cost-effective approach for antibody production. The application of rAbs for developing ultrasensitive diagnostic tools ranging from immunoassays to immunosensors, has allowed the researchers to introduce new platforms with high sensitivity and specificity. Additionally, DNA encoding antibodies are directly accessible in these approaches, which enables the application of antibody engineering to increase their sensitivity and specificity. Here, we review the latest studies about the antibody-based ultrasensitive diagnostic platforms for detection of C. difficile bacteria, with an emphasis on rAb technologies.
Collapse
Affiliation(s)
- Hamideh Raeisi
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Masoumeh Azimirad
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hamid Asadzadeh Aghdaei
- Basic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Abbas Yadegar
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mohammad Reza Zali
- Gastroenterology and Liver Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Wang L, Wang X, Chen Z, Liu S. Electrochemical DNA Scaffold-Based Sensing Platform for Multiple Modes of Protein Assay and a Keypad Lock System. Anal Chem 2022; 94:8317-8326. [PMID: 35649122 DOI: 10.1021/acs.analchem.2c00800] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Development of a flexible, easy-to-use, and well-controllable DNA-based sensing platform would provide enormous opportunities to boost molecular diagnosis and signal transduction or information processing. Herein, a duplex DNA scaffold containing a bulge was deployed for the fabrication of a simple and general DNA-based electrochemical sensing platform. It could be harnessed for different signal output behaviors (one signal-off and two signal-on modes) toward a single-step analysis of the target protein. The detection limit toward the target protein could reach about 0.1 nM. Also, it could be used as a streamlined electrochemical workflow for the successive monitoring of protein binding. Furthermore, such an electrochemical sensing platform could be explored for the operation of the concatenated AND logic gates as a molecular keypad lock system. The current sensing platform based on only one duplex DNA scaffold presented features such as simple biosensor design and fabrication, flexible operation for different signal outputs, sensitive and selective protein detection, and expandable logic operation. It thus would pave a broad road toward the development of high-performance biosensors or logic devices to be applied for molecular diagnosis or computing.
Collapse
Affiliation(s)
- Li Wang
- College of Chemistry and Chemical Engineering, Yantai University, 30 Qingquan Road, Yantai 264005, China
| | - Xu Wang
- College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China
| | - Zhiqiang Chen
- College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China
| | - Shufeng Liu
- College of Chemistry and Chemical Engineering, Yantai University, 30 Qingquan Road, Yantai 264005, China
| |
Collapse
|
7
|
Wang L, Li H, Su W, Zhang W, Xu Z, Wang J, Chen J. Fabrication of a Free-Standing MWCNT Electrode by Electric Field Force for an Ultra-Sensitive MicroRNA-21 Nano-Genosensor. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2201791. [PMID: 35599383 DOI: 10.1002/smll.202201791] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/28/2022] [Indexed: 05/21/2023]
Abstract
Abnormal expression of microRNA-21 (miR-21) is considered to be closely associated with the pathogenesis of colorectal cancer. However, great challenges do exist for the development of ultra-sensitive biosensors to detect the abnormal expression of miR-21 due to the low concentration in serum (fm level) at the early stage of colorectal cancer. Therefore, electric field force is used to rotate and rearrange random multi-walled carbon nanotubes (MWCNTs) at the microscale to improve the active sites of the electrode in this study. The free-standing MWCNTs are densely and high-orderly embedded into the bare electrode along the direction of the electric field. Compared to the bare electrode, the peak-current response of the free-standing MWCNT electrode improves by 150 times in cyclic voltammetric measurement. A nano-genosensor based on the free-standing MWCNT electrode is developed for measuring miR-21. The nano-genosensor for miR-21 shows an ultra-high sensitivity of 48.24 µA µm-1 , a wide linear range from 0.01 × 10-15 to 100 × 10-12 m, and a low detection limit of 1.2 × 10-18 m. The present nano-genosensor shows superior performance for miR-21 in human serum samples and demonstrates a potential application for the diagnosis of early stage colorectal cancer.
Collapse
Affiliation(s)
- Li Wang
- Advanced Micro and Nano-Instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
- Shandong Institute of Mechanical Design and Research, Jinan, 250353, China
| | - Huimin Li
- Advanced Micro and Nano-Instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
- Shandong Institute of Mechanical Design and Research, Jinan, 250353, China
| | - Weiguang Su
- Advanced Micro and Nano-Instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
- Shandong Institute of Mechanical Design and Research, Jinan, 250353, China
| | - Wenxian Zhang
- Advanced Micro and Nano-Instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
- Shandong Institute of Mechanical Design and Research, Jinan, 250353, China
| | - Zhipeng Xu
- School of Cellular and Molecular Medicine, University of Bristol, Bristol, BS8 1TD, UK
| | - Jinshen Wang
- Department of Gastrointestinal Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, 250021, China
| | - Jun Chen
- Advanced Micro and Nano-Instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
- Shandong Institute of Mechanical Design and Research, Jinan, 250353, China
| |
Collapse
|
8
|
Farokhinejad F, Lane RE, Lobb RJ, Edwardraja S, Wuethrich A, Howard CB, Trau M. Generation of Nanoyeast Single-Chain Variable Fragments as High-Avidity Biomaterials for Dengue Virus Detection. ACS Biomater Sci Eng 2021; 7:5850-5860. [PMID: 34738789 DOI: 10.1021/acsbiomaterials.1c01001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Bioengineered yeast bio-nanomaterials termed nanoyeasts displaying antibody single-chain variable fragments (scFvs) against diagnostic targets are a promising alternative to monoclonal antibodies (mAbs). A potential limitation for translating nanoyeasts into diagnostic tools is batch-to-batch variability. Herein, we demonstrate a systematic approach for cost-efficient production of highly specific nanoyeasts that enabled accurate dengue virus (DENV) detection by immunoassay (2.5% CV). Yeasts bioengineered to surface express DENV-specific scFvs (up to 66% of the total cell population) were fragmented into nanoyeast fractions trialing sonication, bead beating, and high-pressure disruption methods. Nanoyeast fractions from sonication had optimal target binding, uniform particle size (±89 nm), were stable, and retained diagnostic activity for 7 days at 37 °C compared to traditional mAbs that lost activity after 1 day at 37 °C. We engineered a panel of nanoyeast scFvs targeting DENV nonstructural protein 1 (NS1): (i) specific for serotyping DENV 1-4 and (ii) cross-reactive anti-DENV scFvs that are suitable for "yes/no" diagnostic applications. We demonstrate highly specific nanoyeast scFvs for serotyping DENV. We show that nanoyeast scFvs specifically detect NS1 in simulated patient plasma with a limit of detection of 250 ng/mL, the concentration found in infected patients.
Collapse
Affiliation(s)
- Fahimeh Farokhinejad
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia
| | - Rebecca E Lane
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia
| | - Richard J Lobb
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia
| | - Selvakumar Edwardraja
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia
| | - Alain Wuethrich
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia
| | - Christopher B Howard
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia
| | - Matt Trau
- Centre of Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane, QLD 4072, Australia.,School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD 4072, Australia
| |
Collapse
|
9
|
Li J, Wuethrich A, Edwardraja S, Lobb RJ, Puttick S, Rose S, Howard CB, Trau M. Amplification-Free SARS-CoV-2 Detection Using Nanoyeast-scFv and Ultrasensitive Plasmonic Nanobox-Integrated Nanomixing Microassay. Anal Chem 2021; 93:10251-10260. [PMID: 34264067 PMCID: PMC8290924 DOI: 10.1021/acs.analchem.1c01657] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 07/06/2021] [Indexed: 02/06/2023]
Abstract
The implementation of accurate and sensitive molecular detection for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is paramount to effectively control the ongoing coronavirus disease 2019 (COVID-19) pandemic. In this regard, we herein propose the specific and highly sensitive SARS-CoV-2 detection based on nanoyeast single-chain-variable fragment (scFv) and ultrasensitive plasmonic nanobox-integrated nanomixing microassay. Importantly, this designed platform showcases the utility of nanoyeast-scFvs as specific capture reagents targeting the receptor-binding domain (RBD) of the virus and as monoclonal antibody alternatives suitable for cost-effective mass production and frequent testing. By capitalizing on single-particle active nanoboxes as plasmonic nanostructures for surface-enhanced Raman scattering (SERS), the microassay utilizes highly sensitive Raman signals to indicate virus infection. The developed microassay further integrated nanomixing for accelerating molecular collisions. Through the synergistic working of nanoyeast-scFv, plasmonic nanoboxes, and nanomixing, the highly specific and sensitive SARS-CoV-2 detection is achieved as low as 17 virus/μL without any molecular amplification. We successfully demonstrate SARS-CoV-2 detection in saliva samples of simulated patients at clinically relevant viral loads, suggesting the possibility of this platform for accurate and noninvasive patient screening.
Collapse
Affiliation(s)
- Junrong Li
- Centre
for Personalized Nanomedicine, Australian
Institute for Bioengineering and Nanotechnology, The University of
Queensland, Brisbane, QLD 4072, Australia
| | - Alain Wuethrich
- Centre
for Personalized Nanomedicine, Australian
Institute for Bioengineering and Nanotechnology, The University of
Queensland, Brisbane, QLD 4072, Australia
| | - Selvakumar Edwardraja
- Centre
for Personalized Nanomedicine, Australian
Institute for Bioengineering and Nanotechnology, The University of
Queensland, Brisbane, QLD 4072, Australia
| | - Richard J. Lobb
- Centre
for Personalized Nanomedicine, Australian
Institute for Bioengineering and Nanotechnology, The University of
Queensland, Brisbane, QLD 4072, Australia
| | - Simon Puttick
- Probing
Biosystems Future Science Platform, Commonwealth
Scientific and Industrial Research Organization, Brisbane, QLD 4029, Australia
| | - Stephen Rose
- Probing
Biosystems Future Science Platform, Commonwealth
Scientific and Industrial Research Organization, Brisbane, QLD 4029, Australia
| | - Christopher B. Howard
- Centre
for Personalized Nanomedicine, Australian
Institute for Bioengineering and Nanotechnology, The University of
Queensland, Brisbane, QLD 4072, Australia
| | - Matt Trau
- Centre
for Personalized Nanomedicine, Australian
Institute for Bioengineering and Nanotechnology, The University of
Queensland, Brisbane, QLD 4072, Australia
- School
of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD 4072, Australia
| |
Collapse
|
10
|
Aydın EB, Aydın M, Sezgintürk MK. New Impedimetric Sandwich Immunosensor for Ultrasensitive and Highly Specific Detection of Spike Receptor Binding Domain Protein of SARS-CoV-2. ACS Biomater Sci Eng 2021; 7:3874-3885. [PMID: 34292712 DOI: 10.1021/acsbiomaterials.1c00580] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
An impedance sensing platform-combined conducting nanocomposite layer was fabricated to develop an effective and rapid method for detection of coronavirus infection (COVID-19) specific spike receptor binding domain (RBD) protein, a precious antigen marker of COVID-19 disease. Coronavirus infection has spread globally and swiftly with major impacts on health, economy, and quality of life of communities. Fast and reliable detection of COVID-19 is a very significant issue for the effective treatment of this bad illness. For this aim, first, an Epoxy functional group-substituted thiophene monomer was synthesized and electrodeposited on a single-use indium tin oxide (ITO) platform in the presence of acetylene black by employing a cyclic voltammetry technique; thus, a conducting nanocomposite (C-NC) layer with high conductivity was obtained. This composite was electrodeposited for the first time on the ITO surface to generate a facile and cost-effective impedimetric biosensor. In addition, this composite provided proper attachment points for antibody binding and also supported the biosensor construction. The immuno-specific biointeractions between anti-RBD and RBD proteins hampered the electron transfer between the ITO substrate surface and electrolyte, and this reaction caused variations in impedance signals, and these signals were proportional to the immobilized RBD antigen amounts. The as-prepared immunosensor showed a wide linear dynamic range (0.0012-120 pg/mL), an ultra-low detection limit of 0.58 fg/mL with added superiorities of great selectivity, suitable repeatability, multiple reusability, and excellent reproducibility.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Tekirdağ 59030, Turkey
| | - Muhammet Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Tekirdağ 59030, Turkey
| | - Mustafa Kemal Sezgintürk
- Bioengineering Department, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale 17100, Turkey
| |
Collapse
|
11
|
Kalyani T, Nanda A, Jana SK. Detection of a novel glycodelin biomarker using electrochemical immunosensor for endometriosis. Anal Chim Acta 2020; 1146:146-154. [PMID: 33461710 DOI: 10.1016/j.aca.2020.11.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 11/11/2020] [Accepted: 11/14/2020] [Indexed: 02/04/2023]
Abstract
Endometriosis is one of the important issues in women worldwide, which decreases the quality of women's lives in their reproductive age. The diagnosis of endometriosis is carried out by the invasive procedure, which is expensive and painful. In the last few decades, researchers have given more attention to constructing a suitable biomarker-based biosensor for semi/non-invasive diagnosis of endometriosis. As a result, glycodelin (GLY) was found as a promising biomarker because of its selectivity and sensitivity. To the best of our knowledge, it was the first study that reported the detection of GLY biomarker using an electrochemical immunosensor. Briefly, a label-free electrochemical immunosensing platform was constructed through in-situ surface modification of cysteamine layer and immobilisation of antibody (anti-GLY) with help of glutaraldehyde. The interaction between antigen and antibody was measured using square wave voltammetry (SWV). The SWV signal could decrease proportionally with the increasing GLY concentration ranging from 1 to 1000 ng mL-1 (R2 = 0.9981) and a detection limit (LOD) of 0.43 ng mL-1. Moreover, an immunosensor could exhibit high sensitivity, selectivity, long-term stability, reproducibility and regeneration. Accuracy of the immunosensor was compared with enzyme-linked immunosorbent assay (ELISA), and satisfying results were obtained. The detection of GLY biomarker may be a new possibility for endometriosis diagnosis.
Collapse
Affiliation(s)
- Thangapandi Kalyani
- Department of Biotechnology, National Institute of Technology, Papum Pare, 791112, Arunachal Pradesh, India
| | - Amalesh Nanda
- Department of Biotechnology, National Institute of Technology, Papum Pare, 791112, Arunachal Pradesh, India
| | - Saikat Kumar Jana
- Department of Biotechnology, National Institute of Technology, Papum Pare, 791112, Arunachal Pradesh, India.
| |
Collapse
|
12
|
Yang W, Zhou M, Oturan N, Bechelany M, Cretin M, Oturan MA. Highly efficient and stable Fe IIFe III LDH carbon felt cathode for removal of pharmaceutical ofloxacin at neutral pH. JOURNAL OF HAZARDOUS MATERIALS 2020; 393:122513. [PMID: 32208334 DOI: 10.1016/j.jhazmat.2020.122513] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2020] [Revised: 03/02/2020] [Accepted: 03/09/2020] [Indexed: 06/10/2023]
Abstract
The traditional electro-Fenton (EF) has been facing major challenges including narrow suitable range of pH and non-reusability of catalyst. To overcome these drawbacks we synthesized FeIIFeIII-layered double hydroxide modified carbon felt (FeIIFeIII LDH-CF) cathode via in situ solvo-thermal process. Chemical composition and electrochemical characterization of FeIIFeIII LDH-CF were tested and analyzed. The apparent rate constant of decay kinetics of ofloxacin (OFC) with FeIIFeIII LDH-CF (0.18 min-1) at pH 7 was more than 3 times higher than that of homogeneous EF (0.05 min-1) at pH 3 with 0.1 mM Fe2+ under same current density (9.37 mA cm-2). Also, a series of experiments including evolution of solution pH, iron leaching, OFC removal with trapping agent and quantitative detection of hydroxyl radicals (OH) were conducted, demonstrating the dominant role of OH generated by surface catalyst via ≡ FeII/FeIII on LDH cathode for degradation of organics as well contributing to high efficiency and good stability at neutral pH. Besides, formation and evolution of aromatic intermediates, carboxylic acids and inorganic ions (F-, NH4+ and NO3-) were identified by High-Performance Liquid chromatography, Gas Chromatography-Mass Spectrometry and ionic chromatography analyses. These findings allowed proposing a plausible degradation pathway of OFC by OH generated in the heterogeneous EF process.
Collapse
Affiliation(s)
- Weilu Yang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China; Key Laboratory of Pollution Process and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China; Tianjin Key Laboratory of Environmental Technology for Complex Trans-Media Pollution, Nankai University, Tianjin 300350, China; Université Paris-Est, Laboratoire Géomatériaux et Environnement, EA 4508, UPEM, 5 Bd Descartes, 77454 Marne-la-Vallée, Cedex 2, France
| | - Minghua Zhou
- Key Laboratory of Pollution Process and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China; Tianjin Key Laboratory of Environmental Technology for Complex Trans-Media Pollution, Nankai University, Tianjin 300350, China.
| | - Nihal Oturan
- Université Paris-Est, Laboratoire Géomatériaux et Environnement, EA 4508, UPEM, 5 Bd Descartes, 77454 Marne-la-Vallée, Cedex 2, France
| | - Mikhael Bechelany
- IEM (Institut Européen des Membranes), UMR 5635, CNRS, ENSCM, UM, Université de Montpellier, Place E. Bataillon, F-34095 Montpellier Cedex 5, France
| | - Marc Cretin
- IEM (Institut Européen des Membranes), UMR 5635, CNRS, ENSCM, UM, Université de Montpellier, Place E. Bataillon, F-34095 Montpellier Cedex 5, France
| | - Mehmet A Oturan
- Key Laboratory of Pollution Process and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China; Université Paris-Est, Laboratoire Géomatériaux et Environnement, EA 4508, UPEM, 5 Bd Descartes, 77454 Marne-la-Vallée, Cedex 2, France.
| |
Collapse
|
13
|
Roy N, Yasmin S, Jeon S. Effective electrochemical detection of dopamine with highly active molybdenum oxide nanoparticles decorated on 2, 6 diaminopyridine/reduced graphene oxide. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104501] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
14
|
Shahzad F, Iqbal A, Zaidi SA, Hwang SW, Koo CM. Nafion-stabilized two-dimensional transition metal carbide (Ti3C2Tx MXene) as a high-performance electrochemical sensor for neurotransmitter. J IND ENG CHEM 2019. [DOI: 10.1016/j.jiec.2019.03.061] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
15
|
Daemi S, Moalem-Banhangi M, Ghasemi S, Ashkarran AA. An efficient platform for the electrooxidation of formaldehyde based on amorphous NiWO4 nanoparticles modified electrode for fuel cells. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113270] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
16
|
Enhanced activation of hydrogen peroxide using nitrogen doped graphene for effective removal of herbicide 2,4-D from water by iron-free electrochemical advanced oxidation. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2018.11.196] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
17
|
Dai Y, Abbasi K, DePietro M, Butler S, Liu CC. Advanced fabrication of biosensor on detection of Glypican-1 using S-Acetylmercaptosuccinic anhydride (SAMSA) modification of antibody. Sci Rep 2018; 8:13541. [PMID: 30202003 PMCID: PMC6131508 DOI: 10.1038/s41598-018-31994-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Accepted: 08/28/2018] [Indexed: 12/23/2022] Open
Abstract
Glypican-1 (GPC-1) has been recognized as biomarker of pancreatic cancer. Quantification of GPC-1 level is also pivotal to breast cancer and prostate cancer’s patients. We hereby report the first biosensor for GPC-1 detection. Instead of using crosslinking technique and surface immobilization of antibody, we applied a novel method for biosensor fabrication, using S-Acetylmercaptosuccinic anhydride (SAMSA) to modify the Anti-GPC-1 producing a thiol-linked Anti-GPC-1. The thiol-linked Anti-GPC-1 was then directly formed a single-layer antibody layer on the gold biosensor, minimizing the biosensor preparation steps significantly. Time of Flight Secondary Ions Mass Spectroscopy (TOF-SIMS) characterization verified the thiol-linked antibody layer and demonstrated a unique perspective for surface protein characterization. Differential pulse voltammetry (DPV) was applied to quantify GPC-1 antigen in undiluted human serum with a concentration range of 5,000 pg/µL to 100 pg/µL. The performance of this newly designed biosensor was also compared with modified self-assembled monolayer system fabricated biosensor, demonstrating the high-sensitivity and high-reproducibility of the SAMSA modified antibody based biosensor. This simple fabrication method can also expand to detection of other biomolecules. The simplified operation process shows great potential in clinical application development.
Collapse
Affiliation(s)
- Yifan Dai
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA.,Electronics Design Center, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA
| | - Kevin Abbasi
- Swagelok Center for Surface Analysis of Materials (SCSAM), Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA
| | - Michael DePietro
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA
| | - Samantha Butler
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA
| | - Chung Chiun Liu
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA. .,Electronics Design Center, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, 44106, USA.
| |
Collapse
|
18
|
Li J, Wang J, Grewal YS, Howard CB, Raftery LJ, Mahler S, Wang Y, Trau M. Multiplexed SERS Detection of Soluble Cancer Protein Biomarkers with Gold–Silver Alloy Nanoboxes and Nanoyeast Single-Chain Variable Fragments. Anal Chem 2018; 90:10377-10384. [DOI: 10.1021/acs.analchem.8b02216] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Junrong Li
- Centre for Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Jing Wang
- Centre for Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Yadveer S. Grewal
- Centre for Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Christopher B. Howard
- Centre for Advanced Imaging, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Lyndon J. Raftery
- Centre for Advanced Imaging, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Stephen Mahler
- Centre for Advanced Imaging, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Yuling Wang
- Department of Molecular Sciences, ARC Centre of Excellence for Nanoscale BioPhotonics, Faculty of Science and Engineering, Macquarie University, Sydney, New South Wales 2109, Australia
| | - Matt Trau
- Centre for Personalized Nanomedicine, Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, Queensland 4072, Australia
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
| |
Collapse
|
19
|
Slate AJ, Brownson DAC, Abo Dena AS, Smith GC, Whitehead KA, Banks CE. Exploring the electrochemical performance of graphite and graphene paste electrodes composed of varying lateral flake sizes. Phys Chem Chem Phys 2018; 20:20010-20022. [PMID: 30022207 DOI: 10.1039/c8cp02196a] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report the fabrication, characterisation (SEM/EDX, TEM, XRD, XPS and Raman spectroscopy) and electrochemical properties of graphite and graphene paste electrodes with varying lateral flake sizes. The fabricated paste electrodes are electrochemically analysed using both outer-sphere and inner-sphere redox probes, namely; hexaammineruthenium(iii) chloride, N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD), potassium ferrocyanide(ii) and ammonium ferrous(ii) sulphate. Upon comparison of different graphite paste electrodes, a clear correlation between the lateral flake sizes (La), ranging from 1.5 mm-0.5 μm, and electrochemical activity (heterogeneous electron transfer (HET) kinetics) is evident, where an improvement in the HET is observed at smaller lateral flake sizes. We infer that the beneficial response evident when employing laterally smaller flakes is due to an increased number of edge plane like-sites/defects available upon the electrode surface, facilitating electron transfer. Interestingly, given that the overall lateral flake sizes of the graphenes utilised (10.0-1.3 μm) were significantly smaller than those studied previously, an improvement in HET kinetics was also evident with the reduction of lateral flake size; the extent to which is redox-probe dependent. Improvements are observed up to a distinct point, termed the 'lateral size threshold' (ca. ≤2 μm) where the electrochemical reversible limit is approached. Further support is provided from density functional theory (DFT), exploring the electronic structure (i.e. HOMO-LUMO) as a function of flake size, which demonstrates that the coverage of edge plane like-sites/defects comprising the geometric structure of the relatively small graphene flakes is such that effectively the entire flake has become electrochemically active. In this study, the importance of lateral flake size with respect to electrochemical reactivity at carbon-based electrodes has been demonstrated alongside a structural relationship upon HET performance, a phenomenon that has not previously been described in the literature. Such work is both highly important and informative for the field of electrochemistry and electrode performance, with potential implications in a plethora of areas, ranging from novel renewable energy sources to electroanalytical sensing platforms.
Collapse
Affiliation(s)
- Anthony J Slate
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, M1 5GD, UK.
| | | | | | | | | | | |
Collapse
|
20
|
Wang Y, Lin Y. Study on the Performance of Nano-Titanium Nitride-Coated Stainless Steel Electrodes in Electro-Fenton Systems. NANOMATERIALS 2018; 8:nano8070494. [PMID: 29976860 PMCID: PMC6071263 DOI: 10.3390/nano8070494] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Revised: 06/27/2018] [Accepted: 07/01/2018] [Indexed: 01/23/2023]
Abstract
The electro-Fenton (EF) process is a type of electrochemical oxidation process; ·OH radicals are generated on the cathode using electricity and decolorize dye wastewaters. Most studies on EF systems in the past have focused on the operating parameters of this process. In recent years, the influence of electrode performance on the EF process has begun to receive more attention. In this study, direct nitridation was used to prepare titanium nitride powders, which were thereafter coated on an SUS304 stainless steel substrate. The performance of this system in the treatment of rhodamine B dye wastewaters via the EF process was investigated. The experimental methods used in this work include: (1) scanning electron microscopy (SEM); (2) X-ray diffraction (XRD); (3) electrochemical Tafel curves; (4) linear sweep voltammetry (LSV); (5) and cyclic voltammetry (CV). It was shown that high-purity TiN can be formed at nitriding temperatures above 900 °C, and the strength of the (111) crystal plane increases with the increase in nitriding temperature; the TiN coating effectively activates the reactive surface of the electrode owing to its porous structure. In terms of corrosion resistance, the corrosion potential and corrosion current of the TiN 1000 °C/SUS304 electrode were 116.94 mV and 205 nA/cm2, respectively, and the coating had a coating porosity of 0.89 × 10−7. As compared with SUS304 stainless steel, the TiN 1000 °C/SUS304 composite electrode had a significantly greater degree of corrosion resistance and exhibited higher redox activity in LSV tests. This composite electrode could achieve a decolorization rate of 49.86% after 30 min, and 94.46% after 120 min. In summary, the TiN 1000 °C/SUS304 composite electrode is very stable and has excellent decolorization efficacy in the EF process. Our findings will serve as a useful reference for future studies on EF electrodes.
Collapse
Affiliation(s)
- Yita Wang
- Department of Mechanical and Electro-Mechanical Engineering, Ilan University, Yilan City 26047, Taiwan.
| | - Youchen Lin
- Department of Mechanical and Electro-Mechanical Engineering, Ilan University, Yilan City 26047, Taiwan.
| |
Collapse
|
21
|
Umukoro EH, Peleyeju MG, Idris AO, Ngila JC, Mabuba N, Rhyman L, Ramasami P, Arotiba OA. Photoelectrocatalytic application of palladium decorated zinc oxide-expanded graphite electrode for the removal of 4-nitrophenol: experimental and computational studies. RSC Adv 2018; 8:10255-10266. [PMID: 35540454 PMCID: PMC9078825 DOI: 10.1039/c8ra00180d] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2018] [Accepted: 03/08/2018] [Indexed: 12/24/2022] Open
Abstract
A novel Pd-ZnO-expanded graphite (EG) photoelectrode was constructed from a Pd-ZnO-EG nanocomposite synthesised by a hydrothermal method and characterised using various techniques such as X-ray diffractometry (XRD), Raman spectroscopy, UV-Vis diffuse reflectance spectroscopy, nitrogen adsorption-desorption analysis, transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS). Cyclic voltammetry and photocurrent response measurements were also carried out on the electrode. The Pd-ZnO-EG electrode was employed in the photoelectrocatalytic removal of 4-nitrophenol as a target water pollutant at a neutral pH and with a current density of 7 mA cm-2. Optical studies revealed that the Pd-ZnO-EG absorbed strongly in the visible light region. The Pd-ZnO-EG electrode showed improved photoelectrocatalytic activity in relation to ZnO-EG and EG electrodes for the removal of the 4-nitrophenol. The photocurrent responses showed that the Pd-ZnO-EG nanocomposite electrode could be employed as a good photoelectrode for photoelectrocatalytic processes and environmental remediation such as treatment of industrial waste waters. Density functional theory method was used to model the oxidative degradation of 4-nitrophenol by the hydroxyl radical which generates hydroquinone, benzoquinone, 4-nitrocatechol, 4-nitroresorcinol and the opening of the 4-nitrophenol ring. Furthermore, the hydroxyl radical is regenerated and can further oxidise the ring structure and initiate a new degradation process.
Collapse
Affiliation(s)
| | - Moses G Peleyeju
- Department of Applied Chemistry, University of Johannesburg South Africa
| | - Azeez O Idris
- Department of Applied Chemistry, University of Johannesburg South Africa
| | - Jane C Ngila
- Department of Applied Chemistry, University of Johannesburg South Africa
- Centre for Nanomaterials Science Research, University of Johannesburg South Africa
| | - Nonhlangabezo Mabuba
- Department of Applied Chemistry, University of Johannesburg South Africa
- Centre for Nanomaterials Science Research, University of Johannesburg South Africa
| | - Lydia Rhyman
- Department of Applied Chemistry, University of Johannesburg South Africa
- Computational Chemistry Group, Department of Chemistry, Faculty of Science, University of Mauritius Réduit 80837 Mauritius
| | - Ponnadurai Ramasami
- Department of Applied Chemistry, University of Johannesburg South Africa
- Computational Chemistry Group, Department of Chemistry, Faculty of Science, University of Mauritius Réduit 80837 Mauritius
| | - Omotayo A Arotiba
- Department of Applied Chemistry, University of Johannesburg South Africa
- Centre for Nanomaterials Science Research, University of Johannesburg South Africa
| |
Collapse
|
22
|
Abstract
The rapid diagnosis of many diseases and timely initiation of appropriate treatment are critical determinants that promote optimal clinical outcomes and general public health. Biosensors are now being applied for rapid diagnostics due to their capacity for point-of-care use with minimum need for operator input. Antibody-based biosensors or immunosensors have revolutionized diagnostics for the detection of a plethora of analytes such as disease markers, food and environmental contaminants, biological warfare agents and illicit drugs. Antibodies are ideal biorecognition elements that provide sensors with high specificity and sensitivity. This review describes monoclonal and recombinant antibodies and different immobilization approaches crucial for antibody utilization in biosensors. Examples of applications of a variety of antibody-based sensor formats are also described.
Collapse
|
23
|
Zhao D, Zhang L, Siebold D, DeArmond D, Alvarez NT, Shanov VN, Heineman WR. Electrochemical Studies of Three Dimensional Graphene Foam as an Electrode Material. ELECTROANAL 2017. [DOI: 10.1002/elan.201700057] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Daoli Zhao
- Department of Chemistry University of Cincinnati Cincinnati, Ohio 45221-0172 United States
| | - Lu Zhang
- Department of Mechanical and Materials Engineering University of Cincinnati Cincinnati, OH 4521-0072 United States
| | - David Siebold
- Department of Mechanical and Materials Engineering University of Cincinnati Cincinnati, OH 4521-0072 United States
| | - Derek DeArmond
- Department of Biomedical, Chemical and Environmental Engineering University of Cincinnati, Cincinnati, OH 45221-0012 United States
| | - Noe T. Alvarez
- Department of Biomedical, Chemical and Environmental Engineering University of Cincinnati, Cincinnati, OH 45221-0012 United States
| | - Vesselin N. Shanov
- Department of Mechanical and Materials Engineering University of Cincinnati Cincinnati, OH 4521-0072 United States
- Department of Biomedical, Chemical and Environmental Engineering University of Cincinnati, Cincinnati, OH 45221-0012 United States
| | - William R. Heineman
- Department of Chemistry University of Cincinnati Cincinnati, Ohio 45221-0172 United States
| |
Collapse
|
24
|
Islam F, Haque MH, Yadav S, Islam MN, Gopalan V, Nguyen NT, Lam AK, Shiddiky MJA. An electrochemical method for sensitive and rapid detection of FAM134B protein in colon cancer samples. Sci Rep 2017; 7:133. [PMID: 28273937 PMCID: PMC5428029 DOI: 10.1038/s41598-017-00206-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Accepted: 02/14/2017] [Indexed: 12/29/2022] Open
Abstract
Despite the excellent diagnostic applications of the current conventional immunoassay methods such as ELISA, immunostaining and Western blot for FAM134B detection, they are laborious, expensive and required a long turnaround time. Here, we report an electrochemical approach for rapid, sensitive, and specific detection of FAM134B protein in biological (colon cancer cell extracts) and clinical (serum) samples. The approach utilises a differential pulse voltammetry (DPV) in the presence of the [Fe(CN)6]3-/4- redox system to quantify the FAM134B protein in a two-step strategy that involves (i) initial attachment of FAM134B antibody on the surface of extravidin-modified screen-printed carbon electrode, and (ii) subsequent detection of FAM134B protein present in the biological/clinical samples. The assay system was able to detect FAM134B protein at a concentration down to 10 pg μL-1 in phosphate buffered saline (pH 7.4) with a good inter-assay reproducibility (% RSD = <8.64, n = 3). We found excellent sensitivity and specificity for the analysis of FAM134B protein in a panel of colon cancer cell lines and serum samples. Finally, the assay was further validated with ELISA method. We believe that our assay could potentially lead a low-cost alternative to conventional immunological assays for target antigens analysis in point-of-care applications.
Collapse
Affiliation(s)
- Farhadul Islam
- Cancer Molecular Pathology Laboratory in School of Medicine, Menzies Health Institute Queensland, Griffith University, Gold Coast Campus, Australia
| | - Md Hakimul Haque
- Cancer Molecular Pathology Laboratory in School of Medicine, Menzies Health Institute Queensland, Griffith University, Gold Coast Campus, Australia.,School of Natural Sciences, Griffith University, Nathan Campus, QLD 4111, Australia
| | - Sharda Yadav
- School of Natural Sciences, Griffith University, Nathan Campus, QLD 4111, Australia.,Queensland Micro and Nanotechnology Centre, Griffith University, Nathan Campus, QLD 4111, Australia
| | - Md Nazmul Islam
- School of Natural Sciences, Griffith University, Nathan Campus, QLD 4111, Australia.,Queensland Micro and Nanotechnology Centre, Griffith University, Nathan Campus, QLD 4111, Australia
| | - Vinod Gopalan
- Cancer Molecular Pathology Laboratory in School of Medicine, Menzies Health Institute Queensland, Griffith University, Gold Coast Campus, Australia.
| | - Nam-Trung Nguyen
- Queensland Micro and Nanotechnology Centre, Griffith University, Nathan Campus, QLD 4111, Australia
| | - Alfred K Lam
- Cancer Molecular Pathology Laboratory in School of Medicine, Menzies Health Institute Queensland, Griffith University, Gold Coast Campus, Australia.
| | - Muhammad J A Shiddiky
- School of Natural Sciences, Griffith University, Nathan Campus, QLD 4111, Australia. .,Queensland Micro and Nanotechnology Centre, Griffith University, Nathan Campus, QLD 4111, Australia.
| |
Collapse
|
25
|
Kalimuthu P, Belaidi AA, Schwarz G, Bernhardt PV. Mediated Catalytic Voltammetry of Holo and Heme‐Free Human Sulfite Oxidases. ChemElectroChem 2017. [DOI: 10.1002/celc.201600685] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Palraj Kalimuthu
- School of Chemistry and Molecular Biosciences University of Queensland Brisbane 4072 Australia
| | - Abdel A. Belaidi
- The Florey Institute of Neuroscience and Mental Health University of Melbourne Victoria 3052 Australia
- Institute of Biochemistry Department of Chemistry and Center for Molecular Medicine Cologne University Zülicher Str. 47 50674 Köln Germany
| | - Guenter Schwarz
- Institute of Biochemistry Department of Chemistry and Center for Molecular Medicine Cologne University Zülicher Str. 47 50674 Köln Germany
| | - Paul V. Bernhardt
- School of Chemistry and Molecular Biosciences University of Queensland Brisbane 4072 Australia
| |
Collapse
|
26
|
Mousset E, Ko ZT, Syafiq M, Wang Z, Lefebvre O. Electrocatalytic activity enhancement of a graphene ink-coated carbon cloth cathode for oxidative treatment. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.11.151] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
27
|
Grewal Y, Shiddiky MJA, Mahler SM, Cangelosi GA, Trau M. Nanoyeast and Other Cell Envelope Compositions for Protein Studies and Biosensor Applications. ACS APPLIED MATERIALS & INTERFACES 2016; 8:30649-30664. [PMID: 27762541 PMCID: PMC5114700 DOI: 10.1021/acsami.6b09263] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Accepted: 10/20/2016] [Indexed: 05/06/2023]
Abstract
Rapid progress in disease biomarker discovery has increased the need for robust detection technologies. In the past several years, the designs of many immunoaffinity reagents have focused on lowering costs and improving specificity while also promoting stability. Antibody fragments (scFvs) have long been displayed on the surface of yeast and phage libraries for selection; however, the stable production of such fragments presents challenges that hamper their widespread use in diagnostics. Membrane and cell wall proteins similarly suffer from stability problems when solubilized from their native environment. Recently, cell envelope compositions that maintain membrane proteins in native or native-like lipid environment to improve their stability have been developed. This cell envelope composition approach has now been adapted toward stabilizing antibody fragments by retaining their native cell wall environment. A new class of immunoaffinity reagents has been developed that maintains antibody fragment attachment to yeast cell wall. Herein, we review recent strategies that incorporate cell wall fragments with functional scFvs, which are designed for easy production while maintaining specificity and stability when in use with simple detection platforms. These cell wall based antibody fragments are globular in structure, and heterogeneous in size, with fragments ranging from tens to hundreds of nanometers in size. These fragments appear to retain activity once immobilized onto biosensor surfaces for the specific and sensitive detection of pathogen antigens. They can be quickly and economically generated from a yeast display library and stored lyophilized, at room temperature, for up to a year with little effect on stability. This new format of scFvs provides stability, in a simple and low-cost manner toward the use of scFvs in biosensor applications. The production and "panning" of such antibody cell wall composites are also extremely facile, enabling the rapid adoption of stable and inexpensive affinity reagents for emerging infectious threats.
Collapse
Affiliation(s)
- Yadveer
S. Grewal
- Centre
for Personalised Nanomedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), University of
Queensland, Brisbane, Queensland 4072, Australia
| | - Muhammad J. A. Shiddiky
- Centre
for Personalised Nanomedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), University of
Queensland, Brisbane, Queensland 4072, Australia
| | - Stephen M. Mahler
- ARC Training Centre for Biopharmaceutical Innovation, Australian Institute for Bioengineering and Nanotechnology
(AIBN), University of Queensland, Brisbane, Queensland 4072, Australia
- School
of Chemical Engineering, University of Queensland, Brisbane, Queensland 4072, Australia
| | - Gerard A. Cangelosi
- School
of Public Health, University of Washington, Seattle, Washington 98195, United States
| | - Matt Trau
- Centre
for Personalised Nanomedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), University of
Queensland, Brisbane, Queensland 4072, Australia
- School
of Chemistry and Molecular Biosciences, University of Queensland, Brisbane, Queensland 4072, Australia
| |
Collapse
|
28
|
Mousset E, Wang Z, Hammaker J, Lefebvre O. Physico-chemical properties of pristine graphene and its performance as electrode material for electro-Fenton treatment of wastewater. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.08.002] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
29
|
Shan J, Ma Z. Simultaneous detection of five biomarkers of lung cancer by electrochemical immunoassay. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1941-1] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
30
|
Kokkinos C, Economou A, Prodromidis MI. Electrochemical immunosensors: Critical survey of different architectures and transduction strategies. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.11.020] [Citation(s) in RCA: 96] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
31
|
Foster CW, Brownson DAC, Ruas de Souza AP, Bernalte E, Iniesta J, Bertotti M, Banks CE. Pencil it in: pencil drawn electrochemical sensing platforms. Analyst 2016; 141:4055-64. [DOI: 10.1039/c6an00402d] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Inspired by recent reports concerning the utilisation of hand drawn pencil macroelectrodes (PDEs), we report the fabrication, characterisation (physicochemical and electrochemical) and implementation (electrochemical sensing) of various PDEs drawn upon a flexible polyester substrate.
Collapse
Affiliation(s)
- Christopher W. Foster
- Faculty of Science and Engineering
- Manchester Metropolitan University
- Manchester M15 GD
- UK
| | - Dale A. C. Brownson
- Faculty of Science and Engineering
- Manchester Metropolitan University
- Manchester M15 GD
- UK
| | | | - Elena Bernalte
- Faculty of Science and Engineering
- Manchester Metropolitan University
- Manchester M15 GD
- UK
- Departamento de Química Analítica e IACYS
| | - Jesus Iniesta
- Physical Chemistry Department and Institute of Electrochemistry
- University of Alicante
- 03690 San Vicente del Raspeig
- Spain
| | - Mauro Bertotti
- Instituto de Química – Universidade de São Paulo
- São Paulo
- Brazil
| | - Craig E. Banks
- Faculty of Science and Engineering
- Manchester Metropolitan University
- Manchester M15 GD
- UK
| |
Collapse
|
32
|
Yadav S, Carrascosa LG, Sina AAI, Shiddiky MJA, Hill MM, Trau M. Electrochemical detection of protein glycosylation using lectin and protein–gold affinity interactions. Analyst 2016; 141:2356-61. [DOI: 10.1039/c6an00528d] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
New electrochemical method to detect glycosylation of protein using lectin and protein gold interaction.
Collapse
Affiliation(s)
- Sharda Yadav
- Australian Institute for Bioengineering and Nanotechnology (AIBN)
- The University of Queensland
- Brisbane
- Australia
- The University of Queensland Diamantina Institute
| | - Laura G. Carrascosa
- Australian Institute for Bioengineering and Nanotechnology (AIBN)
- The University of Queensland
- Brisbane
- Australia
| | - Abu A. I. Sina
- Australian Institute for Bioengineering and Nanotechnology (AIBN)
- The University of Queensland
- Brisbane
- Australia
| | - Muhammad J. A. Shiddiky
- Australian Institute for Bioengineering and Nanotechnology (AIBN)
- The University of Queensland
- Brisbane
- Australia
| | - Michelle M. Hill
- Australian Institute for Bioengineering and Nanotechnology (AIBN)
- The University of Queensland
- Brisbane
- Australia
- The University of Queensland Diamantina Institute
| | - Matt Trau
- Australian Institute for Bioengineering and Nanotechnology (AIBN)
- The University of Queensland
- Brisbane
- Australia
- School of Chemistry and Molecular Biosciences
| |
Collapse
|
33
|
Vaidyanathan R, Rauf S, Grewal YS, Spadafora LJ, Shiddiky MJA, Cangelosi GA, Trau M. Enhancing Protein Capture Using a Combination of Nanoyeast Single-Chain Fragment Affinity Reagents and Alternating Current Electrohydrodynamic Forces. Anal Chem 2015; 87:11673-81. [DOI: 10.1021/acs.analchem.5b02490] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Ramanathan Vaidyanathan
- Centre
for Personalized NanoMedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Sakandar Rauf
- Centre
for Personalized NanoMedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Yadveer S. Grewal
- Centre
for Personalized NanoMedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Lauren J. Spadafora
- School
of Public Health, University of Washington, Seattle, Washington 98195, United States
| | - Muhammad J. A. Shiddiky
- Centre
for Personalized NanoMedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Gerard A. Cangelosi
- School
of Public Health, University of Washington, Seattle, Washington 98195, United States
| | - Matt Trau
- Centre
for Personalized NanoMedicine, Australian Institute for Bioengineering
and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane, Queensland 4072, Australia
- School
of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
| |
Collapse
|
34
|
Wang L, Feng F, Ma Z. Novel electrochemical redox-active species: one-step synthesis of polyaniline derivative-Au/Pd and its application for multiplexed immunoassay. Sci Rep 2015; 5:16855. [PMID: 26577799 PMCID: PMC4649611 DOI: 10.1038/srep16855] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Accepted: 10/21/2015] [Indexed: 01/08/2023] Open
Abstract
Electrochemical redox-active species play crucial role in electrochemically multiplexed immunoassays. A one-pot method for synthesizing four kinds of new electrochemical redox-active species was reported using HAuCl4 and Na2PdCl4 as dual oxidating agents and aniline derivatives as monomers. The synthesized polyaniline derivative-Au/Pd composites, namely poly(N-methyl-o-benzenediamine)-Au/Pd, poly(N-phenyl-o-phenylenediamine)-Au/Pd, poly(N-phenyl-p-phenylenediamine)-Au/Pd and poly(3,3',5,5'-tetramethylbenzidine)-Au/Pd, exhibited electrochemical redox activity at -0.65 V, -0.3 V, 0.12 V, and 0.5 V, respectively. Meanwhile, these composites showed high H2O2 electrocatalytic activity because of the presence of Au/Pd. The as-prepared composites were used as electrochemical immunoprobes in simultaneous detection of four tumor biomarkers (carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA199), carbohydrate antigen 72-4 (CA724), and alpha fetoprotein (AFP)). This immunoassay shed light on potential applications in simultaneous gastric cancer (related biomarkers: CEA, CA199, CA724) and liver cancer diagnosis (related biomarkers: CEA, CA199, AFP). The present strategy to the synthesize redox species could be easily extended to other polymers such as polypyrrole derivatives and polythiophene derivatives. This would be of great significance in the electrochemical detection of more analytes.
Collapse
Affiliation(s)
- Liyuan Wang
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Feng Feng
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| |
Collapse
|
35
|
Shah AK, Hill MM, Shiddiky MJA, Trau M. Electrochemical detection of glycan and protein epitopes of glycoproteins in serum. Analyst 2015; 139:5970-6. [PMID: 25267970 DOI: 10.1039/c4an00781f] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Aberrant protein glycosylation is associated with a range of pathological conditions including cancer and possesses diagnostic importance. Translation of glycoprotein biomarkers will be facilitated by the development of a rapid and sensitive analytical platform that simultaneously interrogates both the glycan and protein epitopes of glycoproteins in body fluids such as serum or saliva. To this end, we developed an electrochemical biosensor based on the immobilization of a lectin on the gold electrode surface to recognize/capture a target glycan epitope conjugated to glycoproteins, followed by detection of the protein epitope using a target protein-specific antibody. Electrochemical signals are generated by label-free voltammetric or impedimetric interrogation of a ferro/ferricyanide redox couple (e.g. [Fe(CN)6](3-/4-)) on the sensing surface, where the change in voltammetric current or interfacial electron transfer resistance was measured. The detection system was demonstrated using the model glycoprotein chicken ovalbumin with Sambucus nigra agglutinin type I (SNA lectin), and exhibits femtomolar sensitivity in the background of diluted human serum. The results obtained in this proof-of-concept study demonstrate the possibility of using electrochemical detection for developing cheap point-of-care diagnostics with high specificity and sensitivity for blood glycoprotein biomarkers.
Collapse
Affiliation(s)
- Alok K Shah
- The University of Queensland Diamantina Institute, The University of Queensland, Translational Research Institute, QLD 4102, Australia.
| | | | | | | |
Collapse
|
36
|
Nair GV, Variyam EP. Noninvasive intestinal amebiasis: Entamoeba histolytica colonization without invasion. Curr Opin Infect Dis 2015; 27:465-9. [PMID: 25101557 DOI: 10.1097/qco.0000000000000095] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW Entamoeba histolytica infection remains a major cause of morbidity and mortality worldwide. Although research with the organism began in the late nineteenth century, our understanding of the natural history of the infection remains incomplete and is heavily based on expert opinion. Most persons infected with E. histolytica are carriers with the organism colonizing the large intestine. Host defense mechanisms that prevent invasive diseases are poorly understood. A timely review could lead to renewed interest. RECENT FINDINGS We herein review 2012 and 2013 publications related to the epidemiology, diagnosis, management and potential mechanisms that enable noninvasive E. histolytica colonization without invasion. SUMMARY There are several publications that advance our knowledge in the first three categories listed above, but studies of mechanisms for noninvasive E. histolytica colonization are glaringly few.
Collapse
Affiliation(s)
- Gayatri V Nair
- aDivision of Infectious Diseases bGastroenterology, Department of Internal Medicine, University of Texas Medical Branch, Galveston, Texas, USA
| | | |
Collapse
|
37
|
Abstract
Among the Entamoeba species that infect humans, Entamoeba histolytica causes diseases, Entamoeba dispar is a harmless commensal, Entamoeba moshkovskii seems to be a pathogen, and the pathogenicity of Entamoeba bangladeshi remains to be investigated. Species-specific detection needed for treatment decisions and for understanding the epidemiology and pathogenicity of these amebae. Antigen-based detection methods are needed for E dispar, E moshkovskii, and E bangladeshi; and molecular diagnostic test capable of detecting E histolytica, E dispar, E moshkovskii, and E bangladeshi simultaneously in clinical samples. Next-generation sequencing of DNA from stool is needed to identify novel species of Entamoeba.
Collapse
Affiliation(s)
- Ibne Karim M Ali
- Division of Foodborne Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Road Northeast, Mailstop D-66, Atlanta, GA 30329, USA.
| |
Collapse
|
38
|
Venkatesh AG, Sun A, Brickner H, Looney D, Hall DA, Aronoff-Spencer E. Yeast dual-affinity biobricks: Progress towards renewable whole-cell biosensors. Biosens Bioelectron 2015; 70:462-8. [PMID: 25863344 DOI: 10.1016/j.bios.2015.03.044] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2015] [Revised: 03/17/2015] [Accepted: 03/19/2015] [Indexed: 12/13/2022]
Abstract
Point-of-care (POC) diagnostic biosensors offer a promising solution to improve healthcare, not only in developed parts of the world, but also in resource limited areas that lack adequate medical infrastructure and trained technicians. However, in remote and resource limited settings, cost and storage of traditional POC immunoassays often limit actual deployment. Synthetically engineered biological components ("BioBricks") provide an avenue to reduce costs and simplify assay procedures. In this article, the design and development of an ultra-low cost, whole-cell "renewable" capture reagent for use in POC diagnostic applications is described. Yeast cells were genetically modified to display both single chain variable fragment (scFv) antibodies and gold-binding peptide (GBP) on their surfaces for simple one step enrichment and surface functionalization. Electrochemical impedance spectroscopy (EIS) and fluorescent imaging were used to verify and characterize the binding of cells to gold electrodes. A complete electrochemical detection assay was then performed on screen-printed electrodes fixed with yeast displaying scFv directed to Salmonella outer membrane protein D (OmpD). Electrochemical assays were optimized and cross-validated with established fluorescence techniques. Nanomolar detection limits were observed for both formats.
Collapse
Affiliation(s)
- A G Venkatesh
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA
| | - Alexander Sun
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA
| | - Howard Brickner
- School of Medicine, University of California, San Diego, La Jolla, CA 92093, USA
| | - David Looney
- VA San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA 92161, USA; School of Medicine, University of California, San Diego, La Jolla, CA 92093, USA
| | - Drew A Hall
- Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA
| | | |
Collapse
|
39
|
Zhu C, Yang G, Li H, Du D, Lin Y. Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal Chem 2015; 87:230-49. [PMID: 25354297 PMCID: PMC4287168 DOI: 10.1021/ac5039863] [Citation(s) in RCA: 807] [Impact Index Per Article: 89.7] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Chengzhou Zhu
- School
of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Guohai Yang
- School
of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - He Li
- School
of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Dan Du
- School
of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Yuehe Lin
- School
of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
- Pacific
Northwest National Laboratory, Richland, Washington 99352, United States
| |
Collapse
|
40
|
Wang Y, Rauf S, Grewal Y, Spadafora LJ, Shiddiky MJA, Cangelosi GA, Schlücker S, Trau M. Duplex microfluidic SERS detection of pathogen antigens with nanoyeast single-chain variable fragments. Anal Chem 2014; 86:9930-8. [PMID: 25192256 PMCID: PMC4188274 DOI: 10.1021/ac5027012] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Accepted: 09/05/2014] [Indexed: 11/30/2022]
Abstract
Quantitative and accurate detection of multiple biomarkers would allow for the rapid diagnosis and treatment of diseases induced by pathogens. Monoclonal antibodies are standard affinity reagents applied for biomarkers detection; however, their production is expensive and labor-intensive. Herein, we report on newly developed nanoyeast single-chain variable fragments (NYscFv) as an attractive alternative to monoclonal antibodies, which offers the unique advantage of a cost-effective production, stability in solution, and target-specificity. By combination of surface-enhanced Raman scattering (SERS) microspectroscopy using glass-coated, highly purified SERS nanoparticle clusters as labels, with a microfluidic device comprising multiple channels, a robust platform for the sensitive duplex detection of pathogen antigens has been developed. Highly sensitive detection for individual Entamoeba histolytica antigen EHI_115350 (limit of detection = 1 pg/mL, corresponding to 58.8 fM) and EHI_182030 (10 pg/mL, corresponding 453 fM) with high specificity has been achieved, employing the newly developed corresponding NYscFv as probe in combination with SERS microspectroscopy at a single laser excitation wavelength. Our first report on SERS-based immunoassays using the novel NYscFv affinity reagent demonstrates the flexibility of NYscFv fragments as viable alternatives to monoclonal antibodies in a range of bioassay platforms and paves the way for further applications.
Collapse
Affiliation(s)
- Yuling Wang
- Centre for Biomarker
Research and Development, Australian Institute
for Bioengineering and Nanotechnology (AIBN) and School of Chemistry and Molecular
Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
- Faculty
of Chemistry, University of Duisburg-Essen, Essen, D-45141, Germany
| | - Sakandar Rauf
- Centre for Biomarker
Research and Development, Australian Institute
for Bioengineering and Nanotechnology (AIBN) and School of Chemistry and Molecular
Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Yadveer
S. Grewal
- Centre for Biomarker
Research and Development, Australian Institute
for Bioengineering and Nanotechnology (AIBN) and School of Chemistry and Molecular
Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Lauren J. Spadafora
- School
for Public Health, University of Washington, Seattle, Washington 98195, United States
| | - Muhammad J. A. Shiddiky
- Centre for Biomarker
Research and Development, Australian Institute
for Bioengineering and Nanotechnology (AIBN) and School of Chemistry and Molecular
Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Gerard A. Cangelosi
- School
for Public Health, University of Washington, Seattle, Washington 98195, United States
| | | | - Matt Trau
- Centre for Biomarker
Research and Development, Australian Institute
for Bioengineering and Nanotechnology (AIBN) and School of Chemistry and Molecular
Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia
| |
Collapse
|
41
|
Grewal YS, Shiddiky MJ, Spadafora LJ, Cangelosi GA, Trau M. Nano-yeast–scFv probes on screen-printed gold electrodes for detection of Entamoeba histolytica antigens in a biological matrix. Biosens Bioelectron 2014; 55:417-22. [DOI: 10.1016/j.bios.2013.12.043] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Revised: 12/04/2013] [Accepted: 12/18/2013] [Indexed: 11/16/2022]
|
42
|
Shiddiky MJA, Vaidyanathan R, Rauf S, Tay Z, Trau M. Molecular nanoshearing: an innovative approach to shear off molecules with AC-induced nanoscopic fluid flow. Sci Rep 2014; 4:3716. [PMID: 24430114 PMCID: PMC3893656 DOI: 10.1038/srep03716] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2013] [Accepted: 12/19/2013] [Indexed: 11/09/2022] Open
Abstract
Early diagnosis of disease requires highly specific measurement of molecular biomarkers from femto to pico-molar concentrations in complex biological (e.g., serum, blood, etc.) samples to provide clinically useful information. While reaching this detection limit is challenging in itself, these samples contain numerous other non-target molecules, most of which have a tendency to adhere to solid surfaces via nonspecific interactions. Herein, we present an entirely new methodology to physically displace nonspecifically bound molecules from solid surfaces by utilizing a newly discovered “tuneable force”, induced by an applied alternating electric field, which occurs within few nanometers of an electrode surface. This methodology thus offers a unique ability to shear-off loosely bound molecules from the solid/liquid interface. Via this approach, we achieved a 5-fold reduction in nonspecific adsorption of non-target protein molecules and a 1000-fold enhancement for the specific capture of HER2 protein in human serum.
Collapse
Affiliation(s)
- Muhammad J A Shiddiky
- Australian Institute for Bioengineering and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane QLD 4072, Australia
| | - Ramanathan Vaidyanathan
- Australian Institute for Bioengineering and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane QLD 4072, Australia
| | - Sakandar Rauf
- Australian Institute for Bioengineering and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane QLD 4072, Australia
| | - Zhikai Tay
- Australian Institute for Bioengineering and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane QLD 4072, Australia
| | - Matt Trau
- 1] Australian Institute for Bioengineering and Nanotechnology (AIBN), Corner College and Cooper Roads (Bldg 75), The University of Queensland, Brisbane QLD 4072, Australia [2] School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD 4072, Australia
| |
Collapse
|