1
|
Park JA, Kwon Y, Le XA, Vu TH, Park H, Lee H, Choi HK, Park C, Kim MI, Lee T. Construction of a rapid electrochemical biosensor consisting of a nanozyme/aptamer conjugate for waterborne microcystin detection. Analyst 2023; 148:2536-2543. [PMID: 37144330 DOI: 10.1039/d3an00391d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Microcystin-LR (MC-LR) is a hepatotoxin generated by the excessive proliferation of cyanobacteria, which is a threat to humans and wildlife. Therefore, rapid detection of MC-LR is an important challenge. This study describes a rapid electrochemical biosensor comprising nanozymes and aptamers. Alternating current electrothermal flow (ACEF) significantly reduced the MC-LR detection period to 10 min. We also used MnO2/MC-LR aptamer conjugates to improve the sensitivity to MC-LR detection. Here, MnO2 amplified the electrochemical signal and the aptamer showed high selectivity for MC-LR. Under the optimal conditions, the limit of detection (LOD) and selectivity in freshwater were detected using cyclic voltammetry and differential pulse voltammetry. As a result, an LOD of 3.36 pg mL-1 was observed in the linear concentration range of 10 pg mL-1 to 1 μg mL-1. This study quickly and sensitively detected MC-LR in a situation where it causes serious damage worldwide. In addition, the ACEF technology introduction is the first example of MC-LR detection, suggesting a wide range of possibilities for MC-LR biosensors.
Collapse
Affiliation(s)
- Jeong Ah Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Yein Kwon
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Xuan Ai Le
- Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam, Gyeonggi 13120, Republic of Korea.
| | - Trung Hieu Vu
- Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam, Gyeonggi 13120, Republic of Korea.
| | - Hanbin Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Hoseok Lee
- Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, Republic of Korea
| | - Hye Kyu Choi
- Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 121-742, Republic of Korea
| | - Chulhwan Park
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| | - Moon Il Kim
- Department of BioNano Technology, Gachon University, 1342 Seongnamdae-ro, Sujeong-gu, Seongnam, Gyeonggi 13120, Republic of Korea.
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
| |
Collapse
|
2
|
Zanoni C, Spina S, Magnaghi LR, Guembe-Garcia M, Biesuz R, Alberti G. Potentiometric MIP-Modified Screen-Printed Cell for Phenoxy Herbicides Detection. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:16488. [PMID: 36554364 PMCID: PMC9779394 DOI: 10.3390/ijerph192416488] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 11/30/2022] [Accepted: 12/07/2022] [Indexed: 06/17/2023]
Abstract
In this study, a molecularly imprinted polymer (MIP)-based screen-printed cell is developed for detecting phenoxy herbicides using 2-methyl-4-chlorophenoxyacetic acid (MCPA) as the template. MCPA is a phenoxy herbicide widely used since 1945 to control broadleaf weeds via growth regulation, primarily in pasture and cereal crops. The potentiometric cell consists of a silver/silver chloride pseudo-reference electrode and a graphite working electrode coated with a MIP film. The polymeric layer is thermally formed after drop-coating of a pre-polymeric mixture composed of the reagents at the following molar ratio: 1 MCPA: 15 MAA (methacrylic acid): 7 EGDMA (ethylene glycol dimethacrylate). After template removal, the recognition cavities function as the ionophore of a classical ion selective electrode (ISE) membrane. The detected ion is the deprotonated MCPA specie, negatively charged, so the measurements were performed in phosphate buffer at pH 5.5. A linear decrease of the potential with MCPA concentration, ranging from 4 × 10-8 to 1 × 10-6 mol L-1, was obtained. The detection limit and the limit of quantification were, respectively, 10 nmol L-1 and 40 nmol L-1. A Nernstian slope of about -59 mV/dec was achieved. The method has precision and LOD required for MCPA determination in contaminated environmental samples.
Collapse
Affiliation(s)
- Camilla Zanoni
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
| | - Stefano Spina
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
| | - Lisa Rita Magnaghi
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
- Unità di Ricerca di Pavia, INSTM, Via G. Giusti 9, 50121 Firenze, Italy
| | - Marta Guembe-Garcia
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Raffaela Biesuz
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
- Unità di Ricerca di Pavia, INSTM, Via G. Giusti 9, 50121 Firenze, Italy
| | - Giancarla Alberti
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
| |
Collapse
|
3
|
Mikuła E, Katrlík J, Rodrigues LR. Electrochemical Aptasensors for Parkinson's Disease Biomarkers Detection. Curr Med Chem 2022; 29:5795-5814. [PMID: 35619313 DOI: 10.2174/0929867329666220520123337] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 02/07/2022] [Accepted: 03/10/2022] [Indexed: 11/22/2022]
Abstract
BACKGROUND Biomarkers are characteristic molecules that can be measured as indicators of biological process status or condition, exhibiting special relevance in Parkinson's Disease (PD). This disease is a chronic neurodegenerative disorder very difficult to study given the site of pathology and due to a clinical phenotype that fluctuates over time. Currently there is no definitive diagnostic test, thus clinicians hope that the detection of crucial biomarkers will help to the symptomatic and presymptomatic diagnostics and providing surrogate endpoints to demonstrate the clinical efficacy of new treatments. METHODS Electrochemical aptasensors are excellent analytical tools that are used in the detection of PD biomarkers, as they are portable, easy to use, and perform real-time analysis. RESULTS In this review, we discuss the most important clinical biomarkers for PD, highlighting their physiological role and function in the disease. Herein, we review for the first time innovative aptasensors for the detection of current potential PD biomarkers based on electrochemical techniques and discuss future alternatives, including ideal analytical platforms for point-of-care diagnostics. CONCLUSION These new tools will be critical not only in the discovery of sensitive, specific, and reliable biomarkers of preclinical PD, but also in the development of tests that can assist in the early detection and differential diagnosis of parkinsonian disorders and in monitoring disease progression. Various methods for fixing aptamers onto the sensor surfaces, enabling quantitative and specific PD biomarker detection present in synthetic and clinical samples, will also be discussed.
Collapse
Affiliation(s)
- Edyta Mikuła
- Department of Biosensors, Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland
| | - Jaroslav Katrlík
- Institute of Chemistry, Slovak Academy of Sciences, Dúbravská cesta 9, 84538 Bratislava, Slovakia
| | - Ligia R Rodrigues
- Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057, Braga, Portugal
| |
Collapse
|
4
|
Malecka K, Ferapontova EE. Femtomolar Detection of Thrombin in Serum and Cerebrospinal Fluid via Direct Electrocatalysis of Oxygen Reduction by the Covalent G4-Hemin-Aptamer Complex. ACS APPLIED MATERIALS & INTERFACES 2021; 13:37979-37988. [PMID: 33878266 DOI: 10.1021/acsami.1c03784] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Thrombin, a serine protease playing a central role in the coagulation cascade reactions and a potent neurotoxin produced by injured brain endothelial cells, is a recognized cardiac biomarker and a critical biomarker for Alzheimer's disease development. Both in vivo and in vitro, its low physiological concentrations and nonspecific binding of other components of physiological fluids complicate electroanalysis of thrombin. Here, femtomolar levels of thrombin in serum and an artificial cerebrospinal fluid (CSF) were detected by the indicator-free electrochemical methodology exploiting the O2 reduction reaction directly, with no electron transfer mediators, electrocatalyzed by the covalent G4-hemin DNAzyme complex naturally self-assembling upon thrombin binding to the hemin-modified 29-mer DNA aptamer sequence tethered to gold via an alkanethiol linker. Coadsorbed PEG inhibited nonspecific protein binding and allowed the sought signal resolution. The proposed assay exploiting the "oxidase" activity of G4-hemin DNAzyme does not require any coreactants necessary for the traditional peroxidase activity-based assays with this DNAzyme, such as H2O2 and redox mediators, or solution deaeration and allows fast, overall 30 min analysis of thrombin in aerated buffer, CSF, and 1% human serum solutions. This pioneer approach exploiting the oxidase activity G4-hemin DNAzyme is simple, sensitive, and selective and represents a new tool for ultrasensitive electrocatalytic assays based on simple and efficient O2-dependent DNAzyme labels.
Collapse
Affiliation(s)
- Kamila Malecka
- Interdisciplinary Nanoscience Center (iNANO), Science and Technology, Aarhus University, Gustav Wieds Vej 1590-14, Aarhus C DK-8000, Denmark
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, Olsztyn 10-748, Poland
| | - Elena E Ferapontova
- Interdisciplinary Nanoscience Center (iNANO), Science and Technology, Aarhus University, Gustav Wieds Vej 1590-14, Aarhus C DK-8000, Denmark
| |
Collapse
|
5
|
Malecka K, Mikuła E, Ferapontova EE. Design Strategies for Electrochemical Aptasensors for Cancer Diagnostic Devices. SENSORS 2021; 21:s21030736. [PMID: 33499136 PMCID: PMC7866130 DOI: 10.3390/s21030736] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 01/12/2021] [Accepted: 01/18/2021] [Indexed: 02/07/2023]
Abstract
Improved outcomes for many types of cancer achieved during recent years is due, among other factors, to the earlier detection of tumours and the greater availability of screening tests. With this, non-invasive, fast and accurate diagnostic devices for cancer diagnosis strongly improve the quality of healthcare by delivering screening results in the most cost-effective and safe way. Biosensors for cancer diagnostics exploiting aptamers offer several important advantages over traditional antibodies-based assays, such as the in-vitro aptamer production, their inexpensive and easy chemical synthesis and modification, and excellent thermal stability. On the other hand, electrochemical biosensing approaches allow sensitive, accurate and inexpensive way of sensing, due to the rapid detection with lower costs, smaller equipment size and lower power requirements. This review presents an up-to-date assessment of the recent design strategies and analytical performance of the electrochemical aptamer-based biosensors for cancer diagnosis and their future perspectives in cancer diagnostics.
Collapse
Affiliation(s)
- Kamila Malecka
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Str. 10, 10-748 Olsztyn, Poland; (K.M.); (E.M.)
| | - Edyta Mikuła
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Str. 10, 10-748 Olsztyn, Poland; (K.M.); (E.M.)
| | - Elena E. Ferapontova
- Interdisciplinary Nanoscience Center (iNANO), Faculty of Science and Technology, Aarhus University, Gustav Wieds Vej 14, 8000 Aarhus C, Denmark
- Correspondence: ; Tel.: +45-87156703
| |
Collapse
|
6
|
Bottari F, Daems E, de Vries AM, Van Wielendaele P, Trashin S, Blust R, Sobott F, Madder A, Martins JC, De Wael K. Do Aptamers Always Bind? The Need for a Multifaceted Analytical Approach When Demonstrating Binding Affinity between Aptamer and Low Molecular Weight Compounds. J Am Chem Soc 2020; 142:19622-19630. [DOI: 10.1021/jacs.0c08691] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Fabio Bottari
- AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Antwerp, 2020, Belgium
| | - Elise Daems
- AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Antwerp, 2020, Belgium
- BAMS Research Group, Department of Chemistry, University of Antwerp, Antwerp, 2020, Belgium
| | - Anne-Mare de Vries
- NMR and Structure Analysis Research Group, Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, 9000, Belgium
- Organic and Biomimetic Chemistry Research Group, Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, 9000, Belgium
| | - Pieter Van Wielendaele
- Laboratory of Medical Biochemistry, Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, 2610, Belgium
| | - Stanislav Trashin
- AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Antwerp, 2020, Belgium
| | - Ronny Blust
- Sphere Research Group, Department of Biology, University of Antwerp, Antwerp, 2020, Belgium
| | - Frank Sobott
- BAMS Research Group, Department of Chemistry, University of Antwerp, Antwerp, 2020, Belgium
- Astbury Centre for Structural Molecular Biology, School of Molecular and Cellular Biology, University of Leeds, Leeds LS2 9JT, United Kingdom
| | - Annemieke Madder
- Organic and Biomimetic Chemistry Research Group, Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, 9000, Belgium
| | - José C. Martins
- NMR and Structure Analysis Research Group, Department of Organic and Macromolecular Chemistry, Ghent University, Ghent, 9000, Belgium
| | - Karolien De Wael
- AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Antwerp, 2020, Belgium
| |
Collapse
|
7
|
Affiliation(s)
- Xixia Liu
- Hubei Key Laboratory of Edible Wild Plants Conservation and Utilization Hubei Normal University Huangshi China
- Department of Chemistry and Waterloo Institute for Nanotechnology University of Waterloo Waterloo Canada
| | - Juewen Liu
- Department of Chemistry and Waterloo Institute for Nanotechnology University of Waterloo Waterloo Canada
| |
Collapse
|
8
|
Jarczewska M, Malinowska E. The application of antibody-aptamer hybrid biosensors in clinical diagnostics and environmental analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3183-3199. [PMID: 32930180 DOI: 10.1039/d0ay00678e] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The growing number of various diseases and the increase of environmental contamination are the causes for the development of novel methods for their detection. The possibility of the application of affinity-based biosensors for such purposes seems particularly promising as they provide high selectivity and low detection limits. Recently, the usage of hybrid antibody-aptamer sandwich constructs was shown to be more advantageous in terms of working parameters in comparison to aptamer-based and immune-based biosensors. This review is focused on the usage of hybrid antibody-aptamer receptor layers for the determination of clinically and environmentally important target molecules. In this work, antibodies and aptamer molecules are characterized and the methods of their immobilization as well as analytical signal generation are shown. This is followed by the critical presentation of examples of hybrid sandwich biosensors that have been elaborated in the past 12 years.
Collapse
Affiliation(s)
- Marta Jarczewska
- The Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, Warsaw, 00-664, Poland.
| | - Elżbieta Malinowska
- The Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, Warsaw, 00-664, Poland.
- Centre for Advanced Materials and Technologies CEZAMAT, Poleczki 19, 02-822 Warsaw, Poland
| |
Collapse
|
9
|
Dalirirad S, Steckl AJ. Lateral flow assay using aptamer-based sensing for on-site detection of dopamine in urine. Anal Biochem 2020; 596:113637. [PMID: 32087129 DOI: 10.1016/j.ab.2020.113637] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 02/14/2020] [Accepted: 02/16/2020] [Indexed: 11/16/2022]
Abstract
A lateral flow assay using DNA aptamer-based sensing for the detection of dopamine in urine is reported. Dopamine duplex aptamers (hybridized sensor with capture probe) are conjugated to 40-nm Au nanoparticles (AuNPs) with 20T linkers. The detection method is based on the dissociation of the duplex aptamer in the presence of dopamine, with the sensor part undergoing conformational changes and being released from the capture part. Hybridization between the complementary DNA in the test line and the conjugated AuNP-capture DNA produces a red band, whose intensity is related to the dopamine concentration. The minimum detectable concentration obtained by ImageJ analysis was <10 ng/mL (65.2 nM), while the visual limit of detection is estimated to be ~50 ng/mL (normal range of dopamine in urine of 52-480 ng/mL or 0.3-3.13 μM). No cross reactivity to other stress biomarkers in urine was confirmed. These results indicate that this robust and user-friendly point-of-care biosensor has significant potential for providing a cost-effective alternative for dopamine detection in urine.
Collapse
Affiliation(s)
- Shima Dalirirad
- Nanoelectronics Laboratory, University of Cincinnati, Cincinnati, OH, 45255-0030, USA; Department of Physics, University of Cincinnati, Cincinnati, OH, 45255-0030, USA
| | - Andrew J Steckl
- Nanoelectronics Laboratory, University of Cincinnati, Cincinnati, OH, 45255-0030, USA; Department of Electrical Engineering and Computer Science, University of Cincinnati, Cincinnati, OH, 45255-0030, USA.
| |
Collapse
|
10
|
Santos-Cancel M, Simpson LW, Leach JB, White RJ. Direct, Real-Time Detection of Adenosine Triphosphate Release from Astrocytes in Three-Dimensional Culture Using an Integrated Electrochemical Aptamer-Based Sensor. ACS Chem Neurosci 2019; 10:2070-2079. [PMID: 30754968 PMCID: PMC6469990 DOI: 10.1021/acschemneuro.9b00033] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
In this manuscript, we describe the development and application of electrochemical aptamer-based (E-AB) sensors directly interfaced with astrocytes in three-dimensional (3D) cell culture to monitor stimulated release of adenosine triphosphate (ATP). The aptamer-based sensor couples specific detection of ATP, selective performance directly in cell culture media, and seconds time resolution using squarewave voltammetry for quantitative ATP-release measurements. More specifically, we demonstrate the ability to quantitatively monitor ATP release into the extracellular environment after stimulation by the addition of calcium (Ca2+), ionomycin, and glutamate. The sensor response is confirmed to be specific to ATP and requires the presence of astrocytes in culture. For example, PC12 cells do not elicit a sensor response after stimulation with the same stimulants. In addition, we confirmed cell viability in the collagen matrix for all conditions tested. Our hydrogel-sensor interface offers the potential to study the release of small molecule messengers in 3D environments. Given the generality of electrochemical aptamer-based sensors and the demonstrated successful interfacing of sensors with tissue scaffold material, in the long term, we anticipate our sensors will be able to translate from in vitro to in vivo small molecule recordings.
Collapse
Affiliation(s)
| | - Laura W. Simpson
- Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD, USA
| | - Jennie B. Leach
- Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Baltimore, MD, USA
| | - Ryan J. White
- Department of Chemistry, University of Cincinnati, Cincinnati, OH, USA
- Department of Electrical Engineering and Computer Science, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
11
|
Álvarez-Martos I, Møller A, Ferapontova EE. Dopamine Binding and Analysis in Undiluted Human Serum and Blood by the RNA-Aptamer Electrode. ACS Chem Neurosci 2019; 10:1706-1715. [PMID: 30605601 DOI: 10.1021/acschemneuro.8b00616] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Specific analysis of such neurotransmitters as dopamine by the aptamer electrodes in biological fluids is detrimentally affected by nonspecific adsorption of media, particularly pronounced at positive charges of the electrode surface at which dopamine oxidizes. Here, we show that dopamine analysis at the RNA-aptamer/cysteamine-modified electrodes is strongly inhibited in undiluted human serum and blood due to nonspecific interfacial adsorption of serum and blood components. We demonstrate that nonspecific adsorption of serum proteins (but not of blood components) could be minimized when analysis is performed in a flow and injections of serum samples are followed by washing steps in a phosphate buffer solution (PBS) carrier. Under those conditions, the dopamine-aptamer binding affinity in whole human serum of (1.9 ± 0.3) × 104 M-1 s-1 was comparable to the (3.7 ± 0.3) × 104 M-1 s-1 found in PBS, and the dopamine oxidation signal linearly depended on the dopamine concentration, providing a sensitivity of analysis of 73 ± 3 nA μM-1 cm-2 and a LOD of 114 ± 8 nM. The flow-injection apatmer-electrode system was used for direct analysis of basal levels of dopamine in undiluted human serum samples, without using any physical separators (membranes) or filtration procedures. The results suggest a simple strategy for combatting biosurface fouling, otherwise most pronounced at positive electrode potentials used for dopamine detection, and assist in designing more efficient antifouling strategies for biomedical applications.
Collapse
Affiliation(s)
- Isabel Álvarez-Martos
- Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Gustav Wieds Vej 14, DK-8000 Aarhus C, Denmark
| | - Arne Møller
- PET-Centre, Aarhus University Hospital, Aarhus, Denmark
- Center of Functionally Integrative Neuroscience, Aarhus University, Aarhus, Denmark
| | - Elena E. Ferapontova
- Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Gustav Wieds Vej 14, DK-8000 Aarhus C, Denmark
| |
Collapse
|
12
|
Campos R, Borme J, Guerreiro JR, Machado G, Cerqueira MF, Petrovykh DY, Alpuim P. Attomolar Label-Free Detection of DNA Hybridization with Electrolyte-Gated Graphene Field-Effect Transistors. ACS Sens 2019; 4:286-293. [PMID: 30672282 DOI: 10.1021/acssensors.8b00344] [Citation(s) in RCA: 90] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this work, we develop a field-effect transistor with a two-dimensional channel made of a single graphene layer to achieve label-free detection of DNA hybridization down to attomolar concentration, while being able to discriminate a single nucleotide polymorphism (SNP). The SNP-level target specificity is achieved by immobilization of probe DNA on the graphene surface through a pyrene-derivative heterobifunctional linker. Biorecognition events result in a positive gate voltage shift of the graphene charge neutrality point. The graphene transistor biosensor displays a sensitivity of 24 mV/dec with a detection limit of 25 aM: the lowest target DNA concentration for which the sensor can discriminate between a perfect-match target sequence and SNP-containing one.
Collapse
Affiliation(s)
- Rui Campos
- Department of Quantum and Energy Materials, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
| | - Jérôme Borme
- Department of Quantum and Energy Materials, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
| | - Joana Rafaela Guerreiro
- Department of Life Sciences, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
| | - George Machado
- Department of Quantum and Energy Materials, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
- Center of Physics, University of Minho, 4710-057 Braga, Portugal
| | - Maria Fátima Cerqueira
- Department of Quantum and Energy Materials, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
- Center of Physics, University of Minho, 4710-057 Braga, Portugal
| | - Dmitri Y. Petrovykh
- Department of Life Sciences, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
| | - Pedro Alpuim
- Department of Quantum and Energy Materials, International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
- Center of Physics, University of Minho, 4710-057 Braga, Portugal
| |
Collapse
|
13
|
Transition metal complexes based aptamers as optical diagnostic tools for disease proteins and biomolecules. Coord Chem Rev 2019. [DOI: 10.1016/j.ccr.2018.09.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
14
|
McConnell EM, Ventura K, Dwyer Z, Hunt V, Koudrina A, Holahan MR, DeRosa MC. In Vivo Use of a Multi-DNA Aptamer-Based Payload/Targeting System To Study Dopamine Dysregulation in the Central Nervous System. ACS Chem Neurosci 2019; 10:371-383. [PMID: 30160936 DOI: 10.1021/acschemneuro.8b00292] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
The delivery of therapeutics across the blood-brain barrier remains a considerable challenge in investigating central nervous system related processes. In this work, a liposome vehicle was surface-modified with an aptamer that binds to the transferrin receptor and was loaded with two different dopamine-binding aptamer payloads. This system was effectively used to promote the delivery of the aptamer cargo from the peripheral injection site into the brain. The effect of these delivered aptamers on behavior was investigated in vivo in a locomotor task. The first dopamine binding aptamer assessed was a DNA aptamer, the binding of which had been previously validated through the aptamer-based biosensor development reported by several independent research groups. The second aptamer investigated was the result of a novel in vitro selection experiment described herein. Our data suggest that systemic administration of the modified liposomes led to delivery of the dopamine aptamers into the brain. Fluorescence microscopy revealed differential distribution of fluorescence based on the presence or absence of the transferrin receptor aptamer on the surface of fluorescently modified liposomes. In a behavioral experiment using cocaine administration to induce elevated concentrations of neural dopamine, systemic pretreatment with the dopamine aptamer-loaded liposomes reduced cocaine-induced hyperlocomotion. Multiple controls including a transferrin-negative liposome control and transferrin-positive liposomes loaded with either a nonbinding, base-substituted dopamine aptamer or a random oligonucleotide were investigated. None of these controls altered cocaine-induced hyperlocomotion. Chronic systemic administration of the modified liposomes produced no deleterious neurobehavioral or neural degenerative effects. Importantly, this work is one example of an application for this versatile multiaptamer payload/targeting system. Its general application is limited only by the availability of aptamers for specific neural targets.
Collapse
Affiliation(s)
- Erin M. McConnell
- Department of Chemistry, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Katelyn Ventura
- Department of Neuroscience, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Zach Dwyer
- Department of Neuroscience, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Vernon Hunt
- Department of Chemistry, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Anna Koudrina
- Department of Chemistry, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Matthew R. Holahan
- Department of Neuroscience, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Maria C. DeRosa
- Department of Chemistry, Carleton University, Ottawa, ON K1S 5B6, Canada
| |
Collapse
|
15
|
Development of DNA aptamer-based sensor for electrochemical detection of C-reactive protein. Talanta 2018; 189:45-54. [PMID: 30086945 DOI: 10.1016/j.talanta.2018.06.035] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 06/08/2018] [Accepted: 06/10/2018] [Indexed: 01/24/2023]
Abstract
C-reactive protein (CRP) is a crucial biomarker of cardiovascular diseases and for its detection both optical and electrochemical techniques were applied. This study concerns the application of DNA aptamer as recognition layer for CRP detection. For that purpose aptamer immobilization method on gold surface was selected and the content of receptor layer was optimized to ensure an efficient binding to target protein. The quality of the monolayer was verified by the application of chronocoulometry and atomic force microscopy. Using thiolated aptamers provided the formation of layers of highest density and stability. The square-wave voltammetry experiments performed in the presence of methylene blue redox indicator revealed a linear response of aptasensor towards CRP in the range from 1 to 100 pM. Moreover, a DNA aptamer - based sensor showed good selectivity towards C-reactive protein in comparison to interfering proteins including BSA and IgE. Finally, the analysis of CRP in serum sample was conducted using the developed aptasensor.
Collapse
|
16
|
Bagheri E, Abnous K, Alibolandi M, Ramezani M, Taghdisi SM. Triple-helix molecular switch-based aptasensors and DNA sensors. Biosens Bioelectron 2018; 111:1-9. [PMID: 29627731 DOI: 10.1016/j.bios.2018.03.070] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Revised: 03/28/2018] [Accepted: 03/29/2018] [Indexed: 12/31/2022]
Abstract
Utilization of traditional analytical techniques is limited because they are generally time-consuming and require high consumption of reagents, complicated sample preparation and expensive equipment. Therefore, it is of great interest to achieve sensitive, rapid and simple detection methods. It is believed that nucleic acids assays, especially aptamers, are very important in modern life sciences for target detection and biological analysis. Aptamers and DNA-based sensors have been widely used for the design of various sensors owing to their unique features. In recent years, triple-helix molecular switch (THMS)-based aptasensors and DNA sensors have been broadly utilized for the detection and analysis of different targets. The THMS relies on the formation of DNA triplex via Watson-Crick and Hoogsteen base pairings under optimal conditions. This review focuses on recent progresses in the development and applications of electrochemical, colorimetric, fluorescence and SERS aptasensors and DNA sensors, which are based on THMS. Also, the advantages and drawbacks of these methods are discussed.
Collapse
Affiliation(s)
- Elnaz Bagheri
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mona Alibolandi
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ramezani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran; Nanotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
17
|
Álvarez-Martos I, Shahdost-fard F, Ferapontova EE. Wiring of heme enzymes by methylene-blue labeled dendrimers. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.07.161] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
18
|
Ferapontova EE. Electrochemical Analysis of Dopamine: Perspectives of Specific In Vivo Detection. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.05.183] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Kurzątkowska K, Sayin S, Yilmaz M, Radecka H, Radecki J. Gold Electrodes Modified with Calix[4]arene for Electrochemical Determination of Dopamine in the Presence of Selected Neurotransmitters. SENSORS 2017; 17:s17061368. [PMID: 28608815 PMCID: PMC5492125 DOI: 10.3390/s17061368] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 06/01/2017] [Accepted: 06/07/2017] [Indexed: 11/16/2022]
Abstract
Here, we present an electrochemical sensor based on gold electrodes modified with calix[4]arene functionalized with carboxypiperidino groups at the upper rim. It has been demonstrated that these groups are involved in a complex formation with dopamine (DA) on the surface of gold electrodes. The supramolecular complex calix[4]arene–DA created on the gold electrode surface has been characterized electrochemically and the measuring conditions have been optimized. The presented sensor displayed a detection limit in the pM range. The DA determination was performed successfully in the presence of ascorbic acid, uric acid and selected neurotransmitters.
Collapse
Affiliation(s)
- Katarzyna Kurzątkowska
- Department of Biosensors, Institute of Animal Reproduction and Food Research Polish Academy of Science, Tuwima 10 Street, Olsztyn 10-748, Poland.
| | - Serkan Sayin
- Department of Environmental Engineering, Faculty of Engineering, Giresun University, Giresun-28200, Turkey.
| | - Mustafa Yilmaz
- Department of Chemistry, Selcuk University, Konya 42100, Turkey.
| | - Hanna Radecka
- Department of Biosensors, Institute of Animal Reproduction and Food Research Polish Academy of Science, Tuwima 10 Street, Olsztyn 10-748, Poland.
| | - Jerzy Radecki
- Department of Biosensors, Institute of Animal Reproduction and Food Research Polish Academy of Science, Tuwima 10 Street, Olsztyn 10-748, Poland.
| |
Collapse
|
20
|
Álvarez-Martos I, Ferapontova EE. A DNA sequence obtained by replacement of the dopamine RNA aptamer bases is not an aptamer. Biochem Biophys Res Commun 2017; 489:381-385. [PMID: 28576492 DOI: 10.1016/j.bbrc.2017.05.134] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Revised: 05/18/2017] [Accepted: 05/23/2017] [Indexed: 10/19/2022]
Abstract
A unique specificity of the aptamer-ligand biorecognition and binding facilitates bioanalysis and biosensor development, contributing to discrimination of structurally related molecules, such as dopamine and other catecholamine neurotransmitters. The aptamer sequence capable of specific binding of dopamine is a 57 nucleotides long RNA sequence reported in 1997 (Biochemistry, 1997, 36, 9726). Later, it was suggested that the DNA homologue of the RNA aptamer retains the specificity of dopamine binding (Biochem. Biophys. Res. Commun., 2009, 388, 732). Here, we show that the DNA sequence obtained by the replacement of the RNA aptamer bases for their DNA analogues is not able of specific biorecognition of dopamine, in contrast to the original RNA aptamer sequence. This DNA sequence binds dopamine and structurally related catecholamine neurotransmitters non-specifically, as any DNA sequence, and, thus, is not an aptamer and cannot be used neither for in vivo nor in situ analysis of dopamine in the presence of structurally related neurotransmitters.
Collapse
Affiliation(s)
- Isabel Álvarez-Martos
- Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Gustav Wieds Vej 14, DK-8000 Aarhus C, Denmark
| | - Elena E Ferapontova
- Interdisciplinary Nanoscience Center (iNANO), Aarhus University, Gustav Wieds Vej 14, DK-8000 Aarhus C, Denmark.
| |
Collapse
|
21
|
D'Souza OJ, Mascarenhas RJ, Satpati AK, Mane V, Mekhalif Z. Application of a Nanosensor Based on MWCNT-Sodium Dodecyl Sulphate Modified Electrode for the Analysis of a Novel Drug, Alpha-Hydrazinonitroalkene in Human Blood Serum. ELECTROANAL 2017. [DOI: 10.1002/elan.201700114] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Ozma J D'Souza
- Research and Development Centre; Bharathiar University; Coimbatore - 641 014, Tamil Nadu India
| | - Ronald J Mascarenhas
- Research and Development Centre; Bharathiar University; Coimbatore - 641 014, Tamil Nadu India
- Electrochemistry Research Group, Department of Chemistry; St. Joseph's College; Lalbagh Road Bangalore - 560 027 Karnataka India
| | - Ashis K Satpati
- Analytical Chemistry Division, Bhabha Atomic Research Centre; Anushakthi Nagar, Trombay; Mumbai - 400 094, Maharashtra India
| | - Vaijinath Mane
- Department of Chemistry; Indian Institute of Technology; Bombay, Mumbai - 400 076 India
| | - Zineb Mekhalif
- Laboratoire de Chimie et d'Electrochimie des Surface; University of Namur; 61 Rue de Bruxelles B-5000 Namur Belgium
| |
Collapse
|
22
|
|
23
|
Salimian R, Kékedy-Nagy L, Ferapontova EE. Specific Picomolar Detection of a Breast Cancer Biomarker HER-2/neu
Protein in Serum: Electrocatalytically Amplified Electroanalysis by the Aptamer/PEG-Modified Electrode. ChemElectroChem 2017. [DOI: 10.1002/celc.201700025] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Razieh Salimian
- Interdisciplinary Nanoscience Center (iNANO), Faculty of Science and Technology; Aarhus University; Gustav Wieds Vej 14 8000 Aarhus C Denmark
- Center for DNA Nanotechnology (CDNA) at iNANO
- Sharif University of Technology; Teheran Iran
| | - László Kékedy-Nagy
- Interdisciplinary Nanoscience Center (iNANO), Faculty of Science and Technology; Aarhus University; Gustav Wieds Vej 14 8000 Aarhus C Denmark
- Center for DNA Nanotechnology (CDNA) at iNANO
| | - Elena E. Ferapontova
- Interdisciplinary Nanoscience Center (iNANO), Faculty of Science and Technology; Aarhus University; Gustav Wieds Vej 14 8000 Aarhus C Denmark
- Center for DNA Nanotechnology (CDNA) at iNANO
| |
Collapse
|
24
|
Hasanzadeh M, Shadjou N, Guardia MDL. Current advancement in electrochemical analysis of neurotransmitters in biological fluids. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.11.001] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
25
|
Li H, Shen J, Cui R, Sun C, Zhao Y, Wu X, Li N, Tang B. A highly selective and sensitive fluorescent nanosensor for dopamine based on formate bridged Tb(iii) complex and silver nanoparticles. Analyst 2017; 142:4240-4246. [DOI: 10.1039/c7an00961e] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The proposed fluorescent nanosensor can distinguish DA from EP.
Collapse
Affiliation(s)
- Huihui Li
- School of Chemistry and Chemical Engineering
- Shandong University
- Key Laboratory of Colloid and Interface Chemistry (Shandong University)
- Ministry of Education
- Jinan 250100
| | - Jin Shen
- School of Chemistry and Chemical Engineering
- Shandong University
- Key Laboratory of Colloid and Interface Chemistry (Shandong University)
- Ministry of Education
- Jinan 250100
| | - Rongwei Cui
- School of Chemistry and Chemical Engineering
- Shandong University
- Key Laboratory of Colloid and Interface Chemistry (Shandong University)
- Ministry of Education
- Jinan 250100
| | - Chongmei Sun
- School of Chemistry and Chemical Engineering
- Shandong University
- Key Laboratory of Colloid and Interface Chemistry (Shandong University)
- Ministry of Education
- Jinan 250100
| | - Yanyan Zhao
- School of Chemistry and Chemical Engineering
- Shandong University
- Key Laboratory of Colloid and Interface Chemistry (Shandong University)
- Ministry of Education
- Jinan 250100
| | - Xia Wu
- School of Chemistry and Chemical Engineering
- Shandong University
- Key Laboratory of Colloid and Interface Chemistry (Shandong University)
- Ministry of Education
- Jinan 250100
| | - Na Li
- College of Chemistry
- Chemical Engineering and Materials Science
- Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong
- Shandong Normal University
- Jinan 250014
| | - Bo Tang
- College of Chemistry
- Chemical Engineering and Materials Science
- Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong
- Shandong Normal University
- Jinan 250014
| |
Collapse
|
26
|
Electrochemical DNA probe for Hg2+ detection based on a triple-helix DNA and Multistage Signal Amplification Strategy. Biosens Bioelectron 2016; 86:907-912. [DOI: 10.1016/j.bios.2016.07.098] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Revised: 07/14/2016] [Accepted: 07/27/2016] [Indexed: 11/23/2022]
|
27
|
Álvarez-Martos I, Kartashov A, Ferapontova EE. Electron Transfer in Methylene-Blue-Labeled G3 Dendrimers Tethered to Gold. ChemElectroChem 2016. [DOI: 10.1002/celc.201600417] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Isabel Álvarez-Martos
- Interdisciplinary Nanoscience Center (iNANO); Aarhus University; Gustav Wieds Vej 14 DK-8000 Aarhus C Denmark
| | - Andrey Kartashov
- Interdisciplinary Nanoscience Center (iNANO); Aarhus University; Gustav Wieds Vej 14 DK-8000 Aarhus C Denmark
| | - Elena E. Ferapontova
- Interdisciplinary Nanoscience Center (iNANO); Aarhus University; Gustav Wieds Vej 14 DK-8000 Aarhus C Denmark
| |
Collapse
|
28
|
Liu L, Xia N, Meng JJ, Zhou BB, Li SJ. An electrochemical aptasensor for sensitive and selective detection of dopamine based on signal amplification of electrochemical-chemical redox cycling. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.05.028] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
29
|
Kékedy-Nagy L, Shipovskov S, Ferapontova EE. Effect of a Dual Charge on the DNA-Conjugated Redox Probe on DNA Sensing by Short Hairpin Beacons Tethered to Gold Electrodes. Anal Chem 2016; 88:7984-90. [DOI: 10.1021/acs.analchem.6b01020] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- László Kékedy-Nagy
- Interdisciplinary
Nanoscience Center, and ‡Center for DNA Nanotechnology at
iNANO, Science and Technology, Aarhus University, Gustav Wieds Vej 1590-14, DK-8000 Aarhus C, Denmark
| | - Stepan Shipovskov
- Interdisciplinary
Nanoscience Center, and ‡Center for DNA Nanotechnology at
iNANO, Science and Technology, Aarhus University, Gustav Wieds Vej 1590-14, DK-8000 Aarhus C, Denmark
| | - Elena E. Ferapontova
- Interdisciplinary
Nanoscience Center, and ‡Center for DNA Nanotechnology at
iNANO, Science and Technology, Aarhus University, Gustav Wieds Vej 1590-14, DK-8000 Aarhus C, Denmark
| |
Collapse
|
30
|
Labib M, Sargent EH, Kelley SO. Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules. Chem Rev 2016; 116:9001-90. [DOI: 10.1021/acs.chemrev.6b00220] [Citation(s) in RCA: 555] [Impact Index Per Article: 69.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Mahmoud Labib
- Department
of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario M5S 3M2, Canada
| | | | - Shana O. Kelley
- Department
of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario M5S 3M2, Canada
- Institute
of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G4, Canada
| |
Collapse
|
31
|
Castaing V, Álvarez-Martos I, Ferapontova EE. Wiring of Glucose Oxidizing Flavin Adenine Dinucleotide-Dependent Enzymes by Methylene Blue-Modified Third Generation Poly(amidoamine) Dendrimers Attached to Spectroscopic Graphite Electrodes. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.01.217] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
32
|
Álvarez-Martos I, Ferapontova EE. Electrochemical Label-Free Aptasensor for Specific Analysis of Dopamine in Serum in the Presence of Structurally Related Neurotransmitters. Anal Chem 2016; 88:3608-16. [PMID: 26916821 DOI: 10.1021/acs.analchem.5b04207] [Citation(s) in RCA: 74] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Cellular and brain metabolism of dopamine can be correlated with a number of neurodegenerative disorders, and as such, in vivo analysis of dopamine in the presence of structurally related neurotransmitters (NT) represents a holy grail of neuroscience. Interference from those NTs generally does not allow selective electroanalysis of dopamine, which redox transformation overlaps with those of other catecholamines. In our previous work, we reported an electrochemical RNA-aptamer-based biosensor for specific analysis of dopamine (Analytical Chemistry, 2013; Vol. 85, p 121). However, the overall design of the biosensor restricted its stability and impeded its operation in serum. Here, we show that specific biorecognition and electroanalysis of dopamine in serum can be performed by the RNA aptamer tethered to cysteamine-modified gold electrodes via the alkanethiol linker. The stabilized dopamine aptasensor allowed continuous 20 h amperometric analysis of dopamine in 10% serum within the physiologically important 0.1-1 μM range and in the presence of catechol and such dopamine precursors and metabolites as norepinephrine and l-DOPA. In a flow-injection mode, the aptasensor response to dopamine was ∼1 s, the sensitivity of analysis, optimized by adjusting the aptamer surface coverage, was 67 ± 1 nA μM(-1) cm(-2), and the dopamine LOD was 62 nM. The proposed design of the aptasensor, exploiting both the aptamer alkanethiol tethering to the electrode and screening of the catecholamine-aptamer electrostatic interactions, allows direct monitoring of dopamine levels in biological fluids in the presence of competitive NT and thus may be further applicable in biomedical research.
Collapse
Affiliation(s)
- Isabel Álvarez-Martos
- Interdisciplinary Nanoscience Center (iNANO) and ‡Danish National Research Foundation: Center for DNA Nanotechnology (CDNA), Aarhus University , Gustav Wieds Vej 1590-14, DK-8000 Aarhus C, Denmark
| | - Elena E Ferapontova
- Interdisciplinary Nanoscience Center (iNANO) and ‡Danish National Research Foundation: Center for DNA Nanotechnology (CDNA), Aarhus University , Gustav Wieds Vej 1590-14, DK-8000 Aarhus C, Denmark
| |
Collapse
|
33
|
Álvarez-Martos I, Alonso-Bartolomé R, Mulas Hernández V, Anillo A, Costa-García A, García Alonso FJ, Fernández-Abedul MT. Poly(glycidyl methacrylate) as a tunable platform of modifiers for microfluidic devices. REACT FUNCT POLYM 2016. [DOI: 10.1016/j.reactfunctpolym.2016.01.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|