1
|
de Moraes NC, Carvalho RM, Ferreira VS, da Silva RAB, de Melo EI, Petroni JM, Lucca BG. Improving the performance and versatility of microfluidic thread electroanalytical devices by automated injection with electronic pipettes: a new and powerful 3D-printed analytical platform. Mikrochim Acta 2023; 190:461. [PMID: 37926729 DOI: 10.1007/s00604-023-06026-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 09/29/2023] [Indexed: 11/07/2023]
Abstract
Microfluidic cotton thread-based electroanalytical devices (μTEDs) are analytical systems with attractive features such as spontaneous passive flow, low cost, minimal waste production, and good sensitivity. Currently, sample injection in µTEDs is performed by hand using manual micropipettes, which have drawbacks such as inconstant speed and position, dependence of skilled analysts, and need of physical effort of operator during prolonged times, leading to poor reproducibility and risk of strain injury. As an alternative to these inconveniences, we propose, for the first time, the use of electronic micropipettes to carry out automated injections in µTEDs. This new approach avoids all disadvantages of manual injections, while also improving the performance, experience, and versatility of µTEDs. The platform developed here is composed by three 3D-printed electrodes (detector) attached to a 3D-printed platform containing an adjustable holder that keeps the electronic pipette in the same x/y/z position. As a proof-of-concept, both injection modes (manual and electronic) were compared using three model analytes (nitrite, paracetamol, and 5-hydroxytryptophan) on µTED with amperometric detection. As result, improved analytical performance (limits of detection between 2.5- and 5-fold lower) was obtained when using electronic injections, as well as better repeatability/reproducibility and higher analytical frequencies. In addition, the determination of paracetamol in urine samples suggested better precision and accuracy for automated injection. Thus, electronic injection is a great advance and changes the state-of-art of µTEDs, mainly considering the use of more modern and versatile electronic pipettes (wider range of pre-programmed modes), which can lead to the development of even more automated systems.
Collapse
Affiliation(s)
- Natália Canhete de Moraes
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | - Rayan Marcel Carvalho
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | - Valdir Souza Ferreira
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | | | - Edmar Isaias de Melo
- Institute of Chemistry, Federal University of Uberlândia, Monte Carmelo, MG, 38500-000, Brazil
| | | | - Bruno Gabriel Lucca
- Institute of Chemistry, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil.
| |
Collapse
|
2
|
Dos Santos VW, Martins G, Gogola JL, Kalinke C, Agustini D, Bergamini MF, Marcolino-Junior LH. Simultaneous detection of dopamine and ascorbic acid by using a thread-based microfluidic device and multiple pulse amperometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4862-4869. [PMID: 37702326 DOI: 10.1039/d3ay00693j] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
This study presents a novel approach for the simultaneous detection of ascorbic acid (AA) and dopamine (DA) using an affordable and user-friendly microfluidic device. Microfluidic devices, when combined with electrochemical detectors like screen-printed electrodes (SPEs), offer numerous advantages such as portability, high sample throughput, and low reagent consumption. In this study, a 3D-printed microfluidic device called a μTED was developed, utilizing textile threads as microfluidic channels and an unmodified SPE as the amperometric detector. The method employed multiple pulse amperometry (MPA) with carefully selected potential values (+0.65 V and -0.10 V). The reduction current signals generated by dopamine o-quinone were used to calculate a correction factor for the oxidation signals of ascorbic acid, enabling simultaneous quantification. The developed microfluidic device ensured a stable flow rate of the carrier solution at 1.19 μL s-1, minimizing the consumption of samples and reagents (injection volume of 2.0 μL). Under the optimized experimental conditions, a linear range from 50 to 900 μmol L-1 was achieved for both DA and AA. The obtained sensitivities were 2.24 μA L mmol-1 for AA and 5.09 μA L mmol-1 for DA, with corresponding limits of detection (LOD) of 2.60 μmol L-1 and 1.54 μmol L-1, respectively. To confirm the effectiveness of the proposed method, it was successfully applied to analyze AA and DA in a commercial blood serum sample spiked at three different concentration levels, with a medium recovery rate of 70%. Furthermore, the MPA technique demonstrated its simplicity by enabling the simultaneous determination of AA and DA without the need for prior separation steps or the use of chemically modified electrodes.
Collapse
Affiliation(s)
- Vanessa W Dos Santos
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Gustavo Martins
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Jeferson L Gogola
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Cristiane Kalinke
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
- Institute of Chemistry, University of Campinas (UNICAMP), CEP 13083-859, Campinas, SP, Brazil
| | - Deonir Agustini
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Márcio F Bergamini
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| | - Luiz H Marcolino-Junior
- Laboratory of Electrochemical Sensors (LabSensE), Chemistry Department, Federal University of Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
| |
Collapse
|
3
|
Iftikhar FJ, Shah A, Wali Q, Kokab T. Advancements in Nanofiber-Based Electrochemical Biosensors for Diagnostic Applications. BIOSENSORS 2023; 13:bios13040416. [PMID: 37185491 PMCID: PMC10136113 DOI: 10.3390/bios13040416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/20/2023] [Accepted: 03/22/2023] [Indexed: 05/17/2023]
Abstract
Biosensors are analytical tools that can be used as simple, real-time, and effective devices in clinical diagnosis, food analysis, and environmental monitoring. Nanoscale functional materials possess unique properties such as a large surface-to-volume ratio, making them useful for biomedical diagnostic purposes. Nanoengineering has resulted in the increased use of nanoscale functional materials in biosensors. Various types of nanostructures i.e., 0D, 1D, 2D, and 3D, have been intensively employed to enhance biosensor selectivity, limit of detection, sensitivity, and speed of response time to display results. In particular, carbon nanotubes and nanofibers have been extensively employed in electrochemical biosensors, which have become an interdisciplinary frontier between material science and viral disease detection. This review provides an overview of the current research activities in nanofiber-based electrochemical biosensors for diagnostic purposes. The clinical applications of these nanobiosensors are also highlighted, along with a discussion of the future directions for these materials in diagnostics. The aim of this review is to stimulate a broader interest in developing nanofiber-based electrochemical biosensors and improving their applications in disease diagnosis. In this review, we summarize some of the most recent advances achieved in point of care (PoC) electrochemical biosensor applications, focusing on new materials and modifiers enabling biorecognition that have led to improved sensitivity, specificity, stability, and response time.
Collapse
Affiliation(s)
- Faiza Jan Iftikhar
- School of Applied Sciences & Humanities, National University of Technology, Islamabad 44000, Pakistan
| | - Afzal Shah
- Department of Chemistry, Quaid-i-Azam University, Islamabad 45320, Pakistan
| | - Qamar Wali
- School of Applied Sciences & Humanities, National University of Technology, Islamabad 44000, Pakistan
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Tayyaba Kokab
- Department of Chemistry, Quaid-i-Azam University, Islamabad 45320, Pakistan
| |
Collapse
|
4
|
Zhao Z, Xiao J, Zhang X, Jiang J, Zhang M, Li Y, Li T, Wang J. A Thread-based Micro Device for Continuous Electrochemical Detection of Saliva Urea. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
|
5
|
Chen L, Ghiasvand A, Paull B. Applications of thread-based microfluidics: Approaches and options for detection. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
|
6
|
Lerin-Morales KM, Olguín LF, Mateo-Martí E, Colín-García M. Prebiotic Chemistry Experiments Using Microfluidic Devices. Life (Basel) 2022; 12:life12101665. [PMID: 36295100 PMCID: PMC9605377 DOI: 10.3390/life12101665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/15/2022] [Accepted: 10/18/2022] [Indexed: 11/16/2022] Open
Abstract
Microfluidic devices are small tools mostly consisting of one or more channels, with dimensions between one and hundreds of microns, where small volumes of fluids are manipulated. They have extensive use in the biomedical and chemical fields; however, in prebiotic chemistry, they only have been employed recently. In prebiotic chemistry, just three types of microfluidic devices have been used: the first ones are Y-form devices with laminar co-flow, used to study the precipitation of minerals in hydrothermal vents systems; the second ones are microdroplet devices that can form small droplets capable of mimic cellular compartmentalization; and the last ones are devices with microchambers that recreate the microenvironment inside rock pores under hydrothermal conditions. In this review, we summarized the experiments in the field of prebiotic chemistry that employed microfluidic devices. The main idea is to incentivize their use and discuss their potential to perform novel experiments that could contribute to unraveling some prebiotic chemistry questions.
Collapse
Affiliation(s)
- Karen Melissa Lerin-Morales
- Posgrado en Ciencias de la Tierra, Universidad Nacional Autónoma de México, Ciudad de Mexico 04510, Mexico
- Correspondence: (K.M.L.-M.); (M.C.-G.); Tel.: +52-(55)-5622-4300 (ext. 164) (M.C.-G.)
| | - Luis F. Olguín
- Laboratorio de Biofisicoquímica, Facultad de Química, Universidad Nacional Autónoma de México, Ciudad de Mexico 04510, Mexico
| | - Eva Mateo-Martí
- Centro de Astrobiología (CAB), CSIC-INTA, Carretera de Ajalvir Km 4, Torrejón de Ardoz, 28850 Madrid, Spain
| | - María Colín-García
- Instituto de Geología, Universidad Nacional Autónoma de México, Ciudad de Mexico 04510, Mexico
- Correspondence: (K.M.L.-M.); (M.C.-G.); Tel.: +52-(55)-5622-4300 (ext. 164) (M.C.-G.)
| |
Collapse
|
7
|
de Oliveira FM, Mendonça MZM, de Moraes NC, Petroni JM, Neves MM, de Melo EI, Lucca BG, Bezerra da Silva RA. Exploring the coating of 3D-printed insulating substrates with conductive composites: a simple, cheap and versatile strategy to prepare customized high-performance electrochemical sensors. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3345-3354. [PMID: 35979860 DOI: 10.1039/d2ay00803c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The development of 3D-printed electrochemical sensors by fused deposition modeling (FDM) has been increasing exponentially in the last five years. In this context, commercial conductive filaments composed of a blend of carbon particles (e.g., graphene or carbon black (CB)) and insulating thermoplastic polymers (e.g., polylactic acid (PLA) or acrylonitrile butadiene styrene (ABS)) have been widely used for electrode fabrication. However, such materials may be expensive and the electrodes when used "as-printed" exhibit poor electrochemical performance as a function of the low content of conductive particles in the composition (∼10 to 20 wt%), which requires one or more post-treatment steps (e.g. polishing, chemical, electrochemical, and photochemical) to reach good electrochemical performance. In this technical note a less used approach to produce "ready-to-use" electrochemical platforms based on 3D printing is explored, which consists of the coating of 3D-printed insulating substrates with homemade conductive composites. To demonstrate the potentiality of this alternative protocol, 3D-printed ABS insulating substrates at two geometries were coated in a highly loaded graphite (55 wt%) homemade composite (G-ABS) and evaluated for the detection of the ferri/ferrocyanide redox probe and model analytes in stationary and hydrodynamic 3D-printed systems (nitrite in micro-flow injection analysis/μFIA and paracetamol in batch injection analysis/BIA, respectively). The analytical parameters acquired with the coated electrodes were comparable to those obtained using conventional electrodes (glassy carbon, boron-doped diamond and carbon screen-printed) and 3D-printed sensors fabricated with commercial filaments. Moreover, the inclusion of carbon black in the fluid conductive composite was demonstrated as a perspective to obtain modified coated 3D-printed surfaces easily for the first time. This alternative "do it yourself" strategy is promising for the large-scale production of very cheap (US$ 0.08) and high-performance electrodes based on FDM 3D printing. Moreover, this approach dispenses the acquisition of commercial conductive filaments and the laborious development of homemade filaments.
Collapse
Affiliation(s)
| | | | | | | | - Matheus Meneguel Neves
- Chemistry Institute, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | - Edmar Isaias de Melo
- Chemistry Institute, Federal University of Uberlândia, Monte Carmelo, MG, 38500-000, Brazil.
| | - Bruno Gabriel Lucca
- Chemistry Institute, Federal University of Mato Grosso Do Sul, Campo Grande, MS, 79074-460, Brazil
| | | |
Collapse
|
8
|
Ongaro AE, Ndlovu Z, Sollier E, Otieno C, Ondoa P, Street A, Kersaudy-Kerhoas M. Engineering a sustainable future for point-of-care diagnostics and single-use microfluidic devices. LAB ON A CHIP 2022; 22:3122-3137. [PMID: 35899603 PMCID: PMC9397368 DOI: 10.1039/d2lc00380e] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 06/20/2022] [Indexed: 06/15/2023]
Abstract
Single-use, disposable, point-of-care diagnostic devices carry great promise for global health, including meeting urgent needs for testing and diagnosis in places with limited laboratory facilities. Unfortunately, the production and disposal of single-use devices, whether in lateral flow assay, cartridges, cassettes, or lab-on-chip microfluidic format, also poses significant challenges for environmental and human health. Point-of-care devices are commonly manufactured from unsustainable polymeric materials derived from fossil sources. Their disposal often necessitates incineration to reduce infection risk, thereby creating additional release of CO2. Many devices also contain toxic chemicals, such as cyanide derivatives, that are damaging to environmental and human health if not disposed of safely. Yet, in the absence of government regulatory frameworks, safe and sustainable waste management for these novel medical devices is often left unaddressed. There is an urgent need to find novel solutions to avert environmental and human harm from these devices, especially in low- and middle-income countries where waste management infrastructure is often weak and where the use of point-of-care tests is projected to rise in coming years. We review here common materials used in the manufacture of single-use point-of-care diagnostic tests, examine the risks they pose to environmental and human health, and investigate replacement materials that can potentially reduce the impact of microfluidic devices on the production of harmful waste. We propose solutions available to point-of-care test developers to start embedding sustainability at an early stage in their design, and to reduce their non-renewable plastic consumption in research and product development.
Collapse
Affiliation(s)
| | - Zibusiso Ndlovu
- Medecins Sans Frontières (MSF), Southern Africa Medical Unit (SAMU), Cape Town, South Africa
| | | | - Collins Otieno
- African Society for Laboratory Medicine (ASLM), Addis Ababa, Ethiopia
| | - Pascale Ondoa
- African Society for Laboratory Medicine (ASLM), Addis Ababa, Ethiopia
| | - Alice Street
- School of Social and Political Sciences, University of Edinburgh, Edinburgh, UK
| | - Maïwenn Kersaudy-Kerhoas
- School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK.
- Infection Medicine, College of Medicine and Veterinary Medicine University of Edinburgh, Edinburgh, UK
| |
Collapse
|
9
|
Oliveira ACM, Araújo DAG, Pradela-Filho LA, Takeuchi RM, Trindade MAG, Dos Santos AL. Threads in tubing: an innovative approach towards improved electrochemical thread-based microfluidic devices. LAB ON A CHIP 2022; 22:3045-3054. [PMID: 35833547 DOI: 10.1039/d2lc00387b] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Thread-based microfluidic analytical devices have received growing attention since threads have some advantages over other materials. Compared to paper, threads are also capable of spontaneously transporting fluid due to capillary action, but they have superior mechanical strength and do not require hydrophobic barriers. Therefore, thread-based microfluidic devices can be inexpensively fabricated with no need for external pumps or sophisticated microfabrication apparatus. Despite these outstanding features, achieving a controlled and continuous flow rate is still a challenging task, mainly due to fluid evaporation. Here, we overcome this challenge by inserting a cotton thread into a polyethylene tube aiming to minimize fluid evaporation. Also, a cotton piece was inserted into the outlet reservoir to improve the wicking ability of the device. This strategy enabled the fabrication of an innovative electrochemical thread in a tubing microfluidic device that was capable to hold a consistent flow rate (0.38 μL s-1) for prolonged periods, allowing up to 100 injections in a single device by simply replacing the cotton piece in the outlet reservoir. The proposed device displayed satisfactory analytical performance for selected model analytes (dopamine, hydrogen peroxide, and tert-butylhydroquinone), in addition to being successfully used for quantification of nitrite in spiked artificial saliva samples. Beyond the flow rate improvement, this "thread-in-tube" strategy ensured the protection of the fluid from external contamination while making it easier to connect the electrode array to the microchannels. Thus, we envision that the thread in a tube strategy could bring interesting improvements to thread-based microfluidic analytical devices.
Collapse
Affiliation(s)
- Ana Clara Maia Oliveira
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Diele Aparecida Gouveia Araújo
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Lauro Antonio Pradela-Filho
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Regina Massako Takeuchi
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| | - Magno Aparecido Gonçalves Trindade
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, 79804-970 Dourados, Mato Grosso do Sul, Brazil
| | - André Luiz Dos Santos
- Instituto de Ciências Exatas e Naturais do Pontal, Universidade Federal de Uberlândia, 38304-402, Ituiutaba, Brazil.
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Brazil
| |
Collapse
|
10
|
3D-printed microfluidic thread device with integrated detector: a green and portable tool for amperometric detection of fungicide benzovindiflupyr in forensic samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Fedalto L, de Oliveira PR, Agustini D, Kalinke C, Banks CE, Bergamini MF, Marcolino-Junior LH. Novel and highly stable strategy for the development of microfluidic enzymatic assays based on the immobilization of horseradish peroxidase (HRP) into cotton threads. Talanta 2022; 252:123889. [DOI: 10.1016/j.talanta.2022.123889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 08/08/2022] [Accepted: 08/24/2022] [Indexed: 10/15/2022]
|
12
|
Selvam G, Dheivasigamani T, Prabhu A, Mani NK. Embellishing 2-D MoS 2 Nanosheets on Lotus Thread Devices for Enhanced Hydrophobicity and Antimicrobial Activity. ACS OMEGA 2022; 7:24606-24613. [PMID: 35874217 PMCID: PMC9301725 DOI: 10.1021/acsomega.2c02337] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Herein, we report cellulose-based threads from Indian sacred Lotus (Nelumbo nucifera) of the Nymphaceae family embellished with MoS2 nanosheets for its enhanced hydrophobic and antimicrobial properties. MoS2 nanosheets synthesized by a coprecipitation method using sodium molybdate dihydrate (Na2MoO4·2H2O) and thioacetamide (CH3CSNH2) were used as a sourse for MoS2 particle growth with cellulose threads extracted from lotus peduncles. The size, crystallinity, and morphology of pure and MoS2-coated fibers were studied using X-ray diffractometry (XRD) and scanning electron microscopy (SEM). the XRD pattern of pure lotus threads showed a semicrystalline nature, and the threads@MoS2 composite showed more crystallinity than the pure threads. SEM depicts that pure lotus threads possess a smooth surface, and the MoS2 nanosheets growth can be easily identified on the threads@MoS2. Further, the presence of MoS2 nanosheets on threads was confirmed with EDX elemental analysis. Antimicrobial studies with Escherichia coli and Candida albicans reveal that threads@MoS2 have better resistance than its counterpart, i.e., pure threads. MoS2 sheets play a predominant role in restricting the wicking capability of the pure threads due to their enhanced hydrophobic property. The water absorbency assay denotes the absorption rate of threads@MoS2 to 80%, and threads@MoS2 shows no penetration for the observed 60 min, thus confirming its wicking restriction. The contact angle for threads@MoS2 is 128°, indicating its improved hydrophobicity.
Collapse
Affiliation(s)
- Govarthini
Seerangan Selvam
- Nano-crystal
Design and Application Lab (n-DAL), Department of Physics, PSG Institute of Technology and Applied Research, Coimbatore-641062, Tamil Nadu India
| | - Thangaraju Dheivasigamani
- Nano-crystal
Design and Application Lab (n-DAL), Department of Physics, PSG Institute of Technology and Applied Research, Coimbatore-641062, Tamil Nadu India
| | - Anusha Prabhu
- Microfluidics,
Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology,
Manipal Institute of Technology, Manipal
Academy of Higher Education, Manipal 576104, Karnataka India
| | - Naresh Kumar Mani
- Microfluidics,
Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology,
Manipal Institute of Technology, Manipal
Academy of Higher Education, Manipal 576104, Karnataka India
| |
Collapse
|
13
|
Chen L, Ghiasvand A, Lam SC, Rodriguez ES, Innis PC, Paull B. Thread-based isotachophoresis coupled with desorption electrospray ionization mass spectrometry for clean-up, preconcentration, and determination of alkaloids in biological fluids. Anal Chim Acta 2022; 1193:338810. [PMID: 35058003 DOI: 10.1016/j.aca.2021.338810] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 06/17/2021] [Accepted: 06/26/2021] [Indexed: 11/01/2022]
Abstract
A thread-based isotachophoresis method coupled with desorption electrospray ionization mass spectrometry (TB-ITP-DESI-MS) was developed and applied for clean-up, preconcentration, and determination of alkaloids in biological fluids. This simple approach enables the focusing and rapid analysis of analytes of interest in complex matrices that are otherwise challenging using direct ambient mass spectrometry. The TB-ITP platform components were rapidly and reproducibly fabricated at low-cost using 3D printing. A single string of nylon 6 thread was used as the electrophoresis substrate and a cotton knot, tied to the nylon thread, was used as the trapping zone of the ITP focused model analytes (coptisine, berberine and palmatine). The trapping efficiency was evaluated upon different commercially available threads with different chemical properties and cotton was selected as the best material due to its highest trapping efficiency and subsequent DESI-MS ionization efficiency. Up to 11.6-fold increase in signal to noise ratio (S/N) was obtained using the proposed method compared to direct DESI-MS detection, due to the reduced matrix interference and focusing. The results demonstrated that the TB-ITP-DESI-MS approach is a viable solution for the analysis of complicated biological fluid samples.
Collapse
Affiliation(s)
- Liang Chen
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Shing Chung Lam
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia
| | - Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia
| | - Peter C Innis
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
14
|
Ho TM, Razzaghi A, Ramachandran A, Mikkonen KS. Emulsion characterization via microfluidic devices: A review on interfacial tension and stability to coalescence. Adv Colloid Interface Sci 2022; 299:102541. [PMID: 34920366 DOI: 10.1016/j.cis.2021.102541] [Citation(s) in RCA: 43] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 09/22/2021] [Accepted: 10/03/2021] [Indexed: 01/29/2023]
Abstract
Emulsions have gained significant importance in many industries including foods, pharmaceuticals, cosmetics, health care formulations, paints, polymer blends and oils. During emulsion generation, collisions can occur between newly-generated droplets, which may lead to coalescence between the droplets. The extent of coalescence is driven by the properties of the dispersed and continuous phases (e.g. density, viscosity, ion strength and pH), and system conditions (e.g. temperature, pressure or any external applied forces). In addition, the diffusion and adsorption behaviors of emulsifiers which govern the dynamic interfacial tension of the forming droplets, the surface potential, and the duration and frequency of the droplet collisions, contribute to the overall rate of coalescence. An understanding of these complex behaviors, particularly those of interfacial tension and droplet coalescence during emulsion generation, is critical for the design of an emulsion with desirable properties, and for the optimization of the processing conditions. However, in many cases, the time scales over which these phenomena occur are extremely short, typically a fraction of a second, which makes their accurate determination by conventional analytical methods extremely challenging. In the past few years, with advances in microfluidic technology, many attempts have demonstrated that microfluidic systems, characterized by micrometer-size channels, can be successfully employed to precisely characterize these properties of emulsions. In this review, current applications of microfluidic devices to determine the equilibrium and dynamic interfacial tension during droplet formation, and to investigate the coalescence stability of dispersed droplets applicable to the processing and storage of emulsions, are discussed.
Collapse
|
15
|
Abstract
Coronaviruses are well known airborne viruses that infect humans, other mammals, and birds. COVID-19 is the disease caused by the last emerging type of corona viruses; SARS-CoV-2 which resulted in the ongoing pandemic. Since its first identification, SARS-CoV-2 has spread globally causing significant morbidity and mortality. Fast and reliable diagnostic methods are crucial to control the virus outbreak. In this chapter, we summarize the traditional methods used to detect corona viruses. Various biosensors used for the detection of the virus antibodies and antigens were briefly discussed. Different biosensing approaches for the detection of corona viruses were presented with special emphasis on the reported biosensors for the detection of SARS-CoV-2. Major advancements in the biosensors area for corona viruses such as the use of cotton, magnetic nanoparticles, graphene, gold nanoparticles, and portable devices are highlighted. The challenges and future perspectives in the biosensors for the detection of corona viruses are discussed.
Collapse
|
16
|
Hasandka A, Singh AR, Prabhu A, Singhal HR, Nandagopal MSG, Mani NK. Paper and thread as media for the frugal detection of urinary tract infections (UTIs). Anal Bioanal Chem 2022; 414:847-865. [PMID: 34668042 PMCID: PMC8724062 DOI: 10.1007/s00216-021-03671-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/02/2021] [Accepted: 09/15/2021] [Indexed: 12/22/2022]
Abstract
Urinary tract infections (UTIs) make up a significant proportion of the global burden of disease in vulnerable groups and tend to substantially impair the quality of life of those affected, making timely detection of UTIs a priority for public health. However, economic and societal barriers drastically reduce accessibility of traditional lab-based testing methods for critical patient groups in low-resource areas, negatively affecting their overall healthcare outcomes. As a result, cellulose-based materials such as paper and thread have garnered significant interest among researchers as substrates for so-called frugal analytical devices which leverage the material's portability and adaptability for facile and reproducible diagnoses of UTIs. Although the field may be only in its infancy, strategies aimed at commercial penetration can appreciably increase access to more healthcare options for at-risk people. In this review, we catalogue recent advances in devices that use cellulose-based materials as the primary housing or medium for UTI detection and chart out trends in the field. We also explore different modalities employed for detection, with particular emphasis on their ability to be ported onto discreet casings such as sanitary products.
Collapse
Affiliation(s)
- Amrutha Hasandka
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Ankita Ramchandran Singh
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Anusha Prabhu
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Hardik Ramesh Singhal
- Department of Chemical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - M S Giri Nandagopal
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, Kharagpur, 721302, India
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
17
|
Eissa S, Al-Kattan K, Zourob M. Combination of Carbon Nanofiber-Based Electrochemical Biosensor and Cotton Fiber: A Device for the Detection of the Middle-East Respiratory Syndrome Coronavirus. ACS OMEGA 2021; 6:32072-32080. [PMID: 34870028 PMCID: PMC8638009 DOI: 10.1021/acsomega.1c04849] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 10/15/2021] [Indexed: 05/28/2023]
Abstract
The miniaturization of biosensors for point-of-care diagnosis is highly important in infection control. Electrochemical biosensors offer several advantages in diagnosis in terms of cost, disposability, portability, and sensitivity. Here, a miniaturized electrochemical immunosensor combined with cotton fiber for the detection of the Middle-East respiratory syndrome coronavirus (MERS-CoV) is described. Taking advantage of the absorption capability of cotton, the nasal and saliva samples can be collected and directly transferred to the immunosensor surface for detection using a single tool. The immunosensor was fabricated on a disposable screen-printed electrode precoated with carbon nanofibers. The electrodes were functionalized with carboxyphenyl groups that were used for the immobilization of the spike protein of the MERS-CoV. A competitive detection scheme was employed using the antibody for the MERS-CoV spike protein, and the square-wave voltammetry technique was used for measurements. The biosensor tested after the cotton coating of the electrode exhibited excellent performance. The biosensor was capable of detecting the MERS-CoV spike protein within a concentration range from 0.1 pg·mL-1 to 1 μg·mL-1 with a limit of detection of 0.07 pg·mL, implying the high sensitivity of the method. The immunosensor did not exhibit any cross-reactivity against proteins from HCoV and Influenza A, indicating the excellent selectivity of this approach. Testing of the biosensor in nasal samples showed very high recovery percentages. This disposable biosensor can be used as a miniaturized device for the collection of samples and detection of the virus using a portable potentiostat connected to a smartphone.
Collapse
Affiliation(s)
- Shimaa Eissa
- Department
of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al
Takhassusi Road, Riyadh 11533, Saudi Arabia
| | - Khaled Al-Kattan
- Department
of Microbiology and Immunology, College of Medicine, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia
| | - Mohammed Zourob
- Department
of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al
Takhassusi Road, Riyadh 11533, Saudi Arabia
| |
Collapse
|
18
|
Melo Henrique J, Rocha Camargo J, Gabriel de Oliveira G, Santos Stefano J, Campos Janegitz B. Disposable electrochemical sensor based on shellac and graphite for sulfamethoxazole detection. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106701] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
19
|
Agustini D, Caetano FR, Quero RF, Fracassi da Silva JA, Bergamini MF, Marcolino-Junior LH, de Jesus DP. Microfluidic devices based on textile threads for analytical applications: state of the art and prospects. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4830-4857. [PMID: 34647544 DOI: 10.1039/d1ay01337h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic devices based on textile threads have interesting advantages when compared to systems made with traditional materials, such as polymers and inorganic substrates (especially silicon and glass). One of these significant advantages is the device fabrication process, made more cheap and simple, with little or no microfabrication apparatus. This review describes the fundamentals, applications, challenges, and prospects of microfluidic devices fabricated with textile threads. A wide range of applications is discussed, integrated with several analysis methods, such as electrochemical, colorimetric, electrophoretic, chromatographic, and fluorescence. Additionally, the integration of these devices with different substrates (e.g., 3D printed components or fabrics), other devices (e.g., smartphones), and microelectronics is described. These combinations have allowed the construction of fully portable devices and consequently the development of point-of-care and wearable analytical systems.
Collapse
Affiliation(s)
- Deonir Agustini
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | - Fábio Roberto Caetano
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | - Reverson Fernandes Quero
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
| | - José Alberto Fracassi da Silva
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), Campinas, SP, Brazil
| | - Márcio Fernando Bergamini
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | | | - Dosil Pereira de Jesus
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), Campinas, SP, Brazil
| |
Collapse
|
20
|
Zhou W, Dou M, Timilsina SS, Xu F, Li X. Recent innovations in cost-effective polymer and paper hybrid microfluidic devices. LAB ON A CHIP 2021; 21:2658-2683. [PMID: 34180494 PMCID: PMC8360634 DOI: 10.1039/d1lc00414j] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Hybrid microfluidic systems that are composed of multiple different types of substrates have been recognized as a versatile and superior platform, which can draw benefits from different substrates while avoiding their limitations. This review article introduces the recent innovations of different types of low-cost hybrid microfluidic devices, particularly focusing on cost-effective polymer- and paper-based hybrid microfluidic devices. In this article, the fabrication of these hybrid microfluidic devices is briefly described and summarized. We then highlight various hybrid microfluidic systems, including polydimethylsiloxane (PDMS)-based, thermoplastic-based, paper/polymer hybrid systems, as well as other emerging hybrid systems (such as thread-based). The special benefits of using these hybrid systems have been summarized accordingly. A broad range of biological and biomedical applications using these hybrid microfluidic devices are discussed in detail, including nucleic acid analysis, protein analysis, cellular analysis, 3D cell culture, organ-on-a-chip, and tissue engineering. The perspective trends of hybrid microfluidic systems involving the improvement of fabrication techniques and broader applications are also discussed at the end of the review.
Collapse
Affiliation(s)
- Wan Zhou
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA.
| | - Maowei Dou
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA.
| | - Sanjay S Timilsina
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA.
| | - Feng Xu
- Bioinspired Engineering and Biomechanics Center (BEBC), The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - XiuJun Li
- Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA. and Border Biomedical Research Center, Biomedical Engineering, University of Texas at El Paso, 500 West University Ave., El Paso, TX 79968, USA and Environmental Science and Engineering, University of Texas at El Paso, 500 West University Ave., El Paso, TX 79968, USA
| |
Collapse
|
21
|
Jiang N, Tansukawat ND, Gonzalez-Macia L, Ates HC, Dincer C, Güder F, Tasoglu S, Yetisen AK. Low-Cost Optical Assays for Point-of-Care Diagnosis in Resource-Limited Settings. ACS Sens 2021; 6:2108-2124. [PMID: 34076428 DOI: 10.1021/acssensors.1c00669] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Readily deployable, low-cost point-of-care medical devices such as lateral flow assays (LFAs), microfluidic paper-based analytical devices (μPADs), and microfluidic thread-based analytical devices (μTADs) are urgently needed in resource-poor settings. Governed by the ASSURED criteria (affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverability) set by the World Health Organization, these reliable platforms can screen a myriad of chemical and biological analytes including viruses, bacteria, proteins, electrolytes, and narcotics. The Ebola epidemic in 2014 and the ongoing pandemic of SARS-CoV-2 have exemplified the ever-increasing importance of timely diagnostics to limit the spread of diseases. This review provides a comprehensive survey of LFAs, μPADs, and μTADs that can be deployed in resource-limited settings. The subsequent commercialization of these technologies will benefit the public health, especially in areas where access to healthcare is limited.
Collapse
Affiliation(s)
- Nan Jiang
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Natha Dean Tansukawat
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Laura Gonzalez-Macia
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - H. Ceren Ates
- Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), University of Freiburg, Freiburg 79110, Germany
- Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, University of Freiburg, Freiburg 79110, Germany
| | - Can Dincer
- Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), University of Freiburg, Freiburg 79110, Germany
- Department of Microsystems Engineering (IMTEK), Laboratory for Sensors, University of Freiburg, Freiburg 79110, Germany
| | - Firat Güder
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Savas Tasoglu
- Department of Mechanical Engineering, Koc University, Sariyer, Istanbul 34450, Turkey
| | - Ali K. Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| |
Collapse
|
22
|
Portable microfluidic devices for in-field detection of pharmaceutical residues in water: Recent outcomes and current technological situation – A short review. CASE STUDIES IN CHEMICAL AND ENVIRONMENTAL ENGINEERING 2021. [DOI: 10.1016/j.cscee.2020.100069] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
23
|
Maximiano EM, Gonçalves DA, Martins CA, Angnes L, Gomes RS, Trindade MAG. Simultaneous separation and electroanalysis in a single polydimethylsiloxane-based platform. Talanta 2021; 233:122514. [PMID: 34215129 DOI: 10.1016/j.talanta.2021.122514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/04/2021] [Accepted: 05/08/2021] [Indexed: 11/15/2022]
Abstract
Channel-based microfluidic devices integrating the separation step and detection system are key factors to expand microanalysis application. However, these devices still depend on macroscale external equipment for pre-treatment of the sample, separation, or detection. The integration of all steps in only one stage is critical to improving feasibility. Herein, we use a low-cost protocol to solve part of the challenge by designing a dual-mode system onto single polydimethylsiloxane (PDMS)-based platform - overall dimensions of 65 mm length × 20 mm width × 14 mm height and the inner diameter of 297±10 μm height × 605±19 μm width - for column-free separation and simultaneous detection. As a proof-of-concept, we used this all-in-one PDMS platform to separate - without the packet-based phase - and determine salicylic acid (SA) and caffeine (CAF) with a detection limit of 0.20 and 0.18 μmol L-1 and quantification limit of 0.70 and 0.60 μmol L-1 for SA and CAF, respectively. We separated the mixture using forced convection into a chemically treated microchannel while detecting the analytes in amperometric mode. Here, we report new insights into how integrating analytes separation and further electroanalysis into a single miniaturized device.
Collapse
Affiliation(s)
- Elizabete M Maximiano
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil
| | - Daniel A Gonçalves
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil
| | - Cauê A Martins
- Institute of Physics, Universidade Federal de Mato Grosso do Sul, CEP 79070-900, Campo Grande, MS, Brazil
| | - Lucio Angnes
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000, São Paulo, SP, Brazil
| | - Roberto S Gomes
- Department of Pharmaceutical Sciences, North Dakota State University, Fargo, ND, USA
| | - Magno A G Trindade
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil; Unesp, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, CEP 14800-900, Araraquara, SP, Brazil.
| |
Collapse
|
24
|
Carvalho RM, Ferreira VS, Lucca BG. A novel all-3D-printed thread-based microfluidic device with an embedded electrochemical detector: first application in environmental analysis of nitrite. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1349-1357. [PMID: 33656036 DOI: 10.1039/d1ay00070e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A microfluidic thread electroanalytical device (μTED) containing an embedded electrochemical detector is presented for the first time in this work. This novel device was entirely produced in an automated way using the fused deposition modeling (FDM) 3D printing technique. The main platform was fabricated with acrylonitrile butadiene styrene (ABS) filament, while the integrated electrochemical detector was produced using a commercial conductive filament composed of carbon black and polylactic acid (CB/PLA). The microfluidic channels consisted of cotton threads, which act as passive pumps, and the μTED was used for microflow injection analysis (μFIA). As a proof of concept, this μFIA system was utilized for the amperometric sensing of nitrite in natural waters. This is the first report on the use of both μTEDs and 3D-printed CB/PLA electrodes to determine this species. This fully 3D-printed μTED was characterized and all experimental and instrumental parameters related to the method were studied and optimized. Using the best conditions, the proposed approach showed a linear response in the concentration range from 8 to 200 μmol L-1 and a limit of detection (LOD) of 2.39 μmol L-1. The LOD obtained here was ca. ten-fold lower than the maximum contaminant level for nitrite in drinking water established by the Brazilian and US legislation. Moreover, the platform presented good repeatability and reproducibility (relative standard deviations (RSDs) were 2.1% and 2.5%, respectively). Lastly, the 3D-printed μTED was applied for the quantification of nitrite in well water samples and the results obtained showed good precision (RSD < 3%) and excellent concordance (relative error was ca.±3%) with those achieved by ion chromatography, used for validation.
Collapse
Affiliation(s)
- Rayan Marcel Carvalho
- Chemistry Institute, Federal University of Mato Grosso do Sul, Campo Grande, MS 79074-460, Brazil.
| | | | | |
Collapse
|
25
|
Ferreira TA, Guevara-Lara A, Paez-Hernandez ME, Mondragon AC, Rodriguez JA. Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels. RSC Adv 2021; 11:35375-35382. [PMID: 35493172 PMCID: PMC9042840 DOI: 10.1039/d1ra06301d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 10/25/2021] [Indexed: 12/03/2022] Open
Abstract
In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (μFIA) with amperometric detection is presented. The method involves the use of henequen modified fibers as microfluidic channels. The μFIA system proposed offers a simple, rapid, and low-cost alternative for the determination. Capillary and gravitational forces across the modified henequen fibers control the flow rate, eliminating the need for external pumps. This technique requires low reagent consumption and allows portability for in situ measurements. The flow system is described, and the operational variables were studied and optimized using a Taguchi parameters design to increase analytical sensitivity. Under optimal conditions a limit of detection of 1.16 μg kg−1 was achieved with adequate repeatability and reproducibility (expressed as %RSD <5.0%, n = 3, n = 9 respectively) in all cases. The effect of interfering species and the accuracy of the method were also investigated. The proposed methodology was validated and applied to determine LMG in tilapia muscle samples. In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (μFIA) with amperometric detection is presented.![]()
Collapse
Affiliation(s)
- T. Alexandra Ferreira
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| | - Alfredo Guevara-Lara
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| | - M. Elena Paez-Hernandez
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| | - Alicia C. Mondragon
- Laboratorio de Higiene, Inspeccion y Control de Alimentos, Departamento de Química Analitica, Nutricion y Bromatologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, 27002, Lugo, Spain
| | - Jose A. Rodriguez
- Area Academica de Quimica, Universidad Autonoma del Estado de Hidalgo, Mineral de la Reforma, Hidalgo, Mexico
| |
Collapse
|
26
|
Sun L, Yang W, Chu H, Yang R, Yu H. Dynamic fabrication of microfluidic systems for particles separation based on optical projection lithography. Biomed Microdevices 2020; 22:80. [PMID: 33170362 DOI: 10.1007/s10544-020-00535-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2020] [Indexed: 11/30/2022]
Abstract
Microfluidic systems are widely used for applications in biology, medicine and chemistry. Particles separation by microfluidics is a scientific subject that requires ongoing research efforts. In this article, we demonstrate a micropillar-based particles separator fabricated using digital micromirror device (DMD)-based optical projection lithography from the perspectives of theory, design, simulation and experiments. Micropillars can be fabricated with customized shapes and sizes which shows high flexible and efficient. The particles separator employs the physical separation of a cylindrical array, a rectangular array, or a triangular array to separate particles. The simulation and experiment results indicate that the device with different micropillars could achieve separation of 20 and 200 μm polystyrene microspheres. Furthermore, the separation efficiency depended on flow rate and the shape of micropillars. All the results can be used to support the redesign of microfluidic structures to address particles separation needs.
Collapse
Affiliation(s)
- Lujing Sun
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Wenguang Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China.
| | - Honghui Chu
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Rendi Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, 264005, China
| | - Haibo Yu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110016, China.,Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, 110016, China
| |
Collapse
|
27
|
Adamo CB, Junger AS, Bressan LP, da Silva JAF, Poppi RJ, de Jesus DP. Fast and straightforward in-situ synthesis of gold nanoparticles on a thread-based microfluidic device for application in surface-enhanced Raman scattering detection. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104985] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
28
|
Hayter EA, Castiaux AD, Martin RS. 3D-Printed Microfluidic Device with In-line Amperometric Detection that Also Enables Multi-Modal Detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:2046-2051. [PMID: 32849919 PMCID: PMC7444025 DOI: 10.1039/d0ay00368a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Microfluidic amperometric detectors often include a reservoir to house auxiliary and reference electrodes, making subsequent detection downstream challenging. Here, we present an in-line microfluidic device with amperometric detection that incorporates a three-electrode set-up, made possible by threading electrodes into a 3D-printed flow cell. The electrodes consist of a commercially available threaded reference electrode and electrodes fabricated in commercially available fittings. This approach centers the working electrode in the fluidic channel enabling the use of a pillar working electrode that is shown to increase sensitivity, as compared to a traditional thin-layer electrode. In addition, the working and auxiliary electrodes can be directly opposed, with this configuration leading to a more uniform potential being applied to the working electrode as well as fewer issues with any iR drop. To demonstrate the ability to incorporate a separate mode of detection downstream from the electrochemical flow cell, the device is modified to include a mixing T for introduction of reagents for chemiluminescent detection of ATP (via the luciferin-luciferase reaction), leading to a single 3D-printed device that can be used to detect norepinephrine and ATP, nearly simultaneously, by amperometry and chemiluminescence, respectively. This approach opens numerous possibilities, where microfluidics with in-line amperometry can be used in continuous circulation studies or in conjunction with other downstream detection events to study complex systems.
Collapse
|
29
|
Pozo G, de la Presa P, Prato R, Morales I, Marin P, Fransaer J, Dominguez-Benetton X. Spin transition nanoparticles made electrochemically. NANOSCALE 2020; 12:5412-5421. [PMID: 32080699 DOI: 10.1039/c9nr09884d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Materials displaying novel magnetic ground states signify the most exciting prospects for nanoscopic devices for nanoelectronics and spintronics. Spin transition materials, e.g., spin liquids and spin glasses, are at the forefront of this pursuit; but the few synthesis routes available do not produce them at the nanoscale. Thus, it remains an open question if and how their spin transition nature persists at such small dimensions. Here we demonstrate a new route to synthesize nanoparticles of spin transition materials, gas-diffusion electrocrystallization (GDEx), wherein the reactive precipitation of soluble metal ions with the products of the oxygen reduction reaction (ORR), i.e., in situ produced H2O2, OH-, drives their formation at the electrochemical interface. Using mixtures of Cu2+ and Zn2+ as the metal precursors, we form spin transition materials of the herbertsmithite family-heralded as the first experimental material known to exhibit the properties of a quantum spin liquid (QSL). Single-crystal nanoparticles of ∼10-16 nm were produced by GDEx, with variable Cu/Zn stoichiometry at the interlayer sites of ZnxCu4-x(OH)6Cl2. For x = 1 (herbertsmithite) the GDEx nanoparticles demonstrated a quasi-QSL behavior, whereas for x = 0.3 (0.3 < x < 1 for paratacamite) and x = 0 (clinoatacamite) a spin-glass behavior was evidenced. Finally, our discovery not only confirms redox reactions as the driving force to produce spin transition nanoparticles, but also proves a simple way to switch between these magnetic ground states within an electrochemical system, paving the way to further explore its reversibility and overarching implications.
Collapse
Affiliation(s)
- Guillermo Pozo
- Separation and Conversion Technologies, VITO, Flemish Institute for Technological Research, Boeretang 200, 2400, Mol, Belgium.
| | | | | | | | | | | | | |
Collapse
|
30
|
Song J, Ouyang Z, Lu W, Cai L. Instrument-free detection of polyphenols with a thread-based analytical device. ROYAL SOCIETY OPEN SCIENCE 2020; 7:192130. [PMID: 32269816 PMCID: PMC7137958 DOI: 10.1098/rsos.192130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 02/11/2020] [Indexed: 06/11/2023]
Abstract
We described an instrument-free method for quantitative analysis of the total content of tea polyphenols by measurement of the length of a coloured band. Polyphenols react with ferrous ions to form a colourless ferrous-polyphenols complex on cotton threads, which could be adsorbed on the threads. The complex was then oxidized to form a blue-black ferric-polyphenols complex, generating a blue-black band on the cotton thread. The length of this blue-black band was then measured to detect the total content of polyphenols. The advantages of this method include low cost, rapid analysis, low consumption, easy fabrication and operation. Furthermore, the digital instrument (scanner or camera) as well as the image processing software are not required. This proposed method was used to detect polyphenols in tea leaf extracts with an analytical result agreeing well with that obtained by a standard method, which demonstrates its potential in monitoring of tea leaf quality, especially in resource-limited regions and settings.
Collapse
Affiliation(s)
| | | | | | - Longfei Cai
- Author for correspondence: Longfei Cai e-mail:
| |
Collapse
|
31
|
Dossi N, Toniolo R, Terzi F, Grazioli C, Svigelj R, Gobbi F, Bontempelli G. A Simple Strategy for Easily Assembling 3D Printed Miniaturized Cells Suitable for Simultaneous Electrochemical and Spectrophotometric Analyses. ELECTROANAL 2020. [DOI: 10.1002/elan.201900461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Nicolò Dossi
- Department of Agrifood, Environmental and Animal ScienceUniversity of Udine via Cotonificio 108 I-33100 Udine Italy
| | - Rosanna Toniolo
- Department of Agrifood, Environmental and Animal ScienceUniversity of Udine via Cotonificio 108 I-33100 Udine Italy
| | - Fabio Terzi
- Department of Chemical and Geological ScienceUniversity of Modena and Reggio Emilia via Campi 183 I-41125 Modena Italy
| | - Cristian Grazioli
- Department of Agrifood, Environmental and Animal ScienceUniversity of Udine via Cotonificio 108 I-33100 Udine Italy
| | - Rossella Svigelj
- Department of Agrifood, Environmental and Animal ScienceUniversity of Udine via Cotonificio 108 I-33100 Udine Italy
| | - Filippo Gobbi
- Department of Agrifood, Environmental and Animal ScienceUniversity of Udine via Cotonificio 108 I-33100 Udine Italy
| | - Gino Bontempelli
- Department of Agrifood, Environmental and Animal ScienceUniversity of Udine via Cotonificio 108 I-33100 Udine Italy
| |
Collapse
|
32
|
Prabhu A, Nandagopal M. S. G, Peralam Yegneswaran P, Prabhu V, Verma U, Mani NK. Thread integrated smart-phone imaging facilitates early turning point colorimetric assay for microbes. RSC Adv 2020; 10:26853-26861. [PMID: 35515782 PMCID: PMC9055509 DOI: 10.1039/d0ra05190j] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 07/13/2020] [Indexed: 12/19/2022] Open
Abstract
A proof-of-concept unifying thread devices and smart-phone imaging for low-cost microbial detection based on simple colour change.
Collapse
Affiliation(s)
- Anusha Prabhu
- Department of Biotechnology
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Giri Nandagopal M. S.
- Department of Mechanical Engineering
- Indian Institute of Technology
- Kharagpur 721302
- India
| | - Prakash Peralam Yegneswaran
- Department of Microbiology
- Kasturba Medical College Manipal
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Vijendra Prabhu
- Department of Biotechnology
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Ujjwal Verma
- Department of Electronics & Communication
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Naresh Kumar Mani
- Department of Biotechnology
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| |
Collapse
|
33
|
Kalinke C, Wosgrau V, Oliveira PR, Oliveira GA, Martins G, Mangrich AS, Bergamini MF, Marcolino-Junior LH. Green method for glucose determination using microfluidic device with a non-enzymatic sensor based on nickel oxyhydroxide supported at activated biochar. Talanta 2019; 200:518-525. [DOI: 10.1016/j.talanta.2019.03.079] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 03/19/2019] [Accepted: 03/20/2019] [Indexed: 01/22/2023]
|
34
|
Weng X, Kang Y, Guo Q, Peng B, Jiang H. Recent advances in thread-based microfluidics for diagnostic applications. Biosens Bioelectron 2019; 132:171-185. [PMID: 30875629 PMCID: PMC7127036 DOI: 10.1016/j.bios.2019.03.009] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/02/2019] [Accepted: 03/07/2019] [Indexed: 02/06/2023]
Abstract
Over the past decades, researchers have been seeking attractive substrate materials to keep microfluidics improving to outbalance the drawbacks and issues. Cellulose substrates, including thread, paper and hydrogels are alternatives due to their distinct structural and mechanical properties for a number of applications. Thread have gained considerable attention and become promising powerful tool due to its advantages over paper-based systems thus finds numerous applications in the development of diagnostic systems, smart bandages and tissue engineering. To the best of our knowledge, no comprehensive review articles on the topic of thread-based microfluidics have been published and it is of significance for many scientific communities working on Microfluidics, Biosensors and Lab-on-Chip. This review gives an overview of the advances of thread-based microfluidic diagnostic devices in a variety of applications. It begins with an overall introduction of the fabrication followed by an in-depth review on the detection techniques in such devices and various applications with respect to effort and performance to date. A few perspective directions of thread-based microfluidics in its development are also discussed. Thread-based microfluidics are still at an early development stage and further improvements in terms of fabrication, analytical strategies, and function to become low-cost, low-volume and easy-to-use point-of-care (POC) diagnostic devices that can be adapted or commercialized for real world applications.
Collapse
Affiliation(s)
- Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Yuejun Kang
- Institute for Clean Energy and Advanced Materials, Faculty of Materials and Energy, Southwest University, Chongqing 400715, China
| | - Qian Guo
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China.
| |
Collapse
|
35
|
Nonenzymatic sensor for determination of glucose in blood plasma based on nickel oxyhydroxide in a microfluidic system of cotton thread. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.03.038] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
36
|
Farajikhah S, Cabot JM, Innis PC, Paull B, Wallace G. Life-Saving Threads: Advances in Textile-Based Analytical Devices. ACS COMBINATORIAL SCIENCE 2019; 21:229-240. [PMID: 30640423 DOI: 10.1021/acscombsci.8b00126] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Novel approaches that incorporate electrofluidic and microfluidic technologies are reviewed to illustrate the translation of traditional enclosed structures into open and accessible textile based platforms. Through the utilization of on-fiber and on-textile microfluidics, it is possible to invert the typical enclosed capillary column or microfluidic "chip" platform, to achieve surface accessible efficient separations and fluid handling, while maintaining a microfluidic environment. The open fiber/textile based fluidics approach immediately provides new possibilities to interrogate, manipulate, redirect, extract, characterize, and quantify solutes and target species at any point in time during such processes as on-fiber electrodriven separations. This approach is revolutionary in its simplicity and provides many potential advantages not otherwise afforded by the more traditional enclosed platforms.
Collapse
Affiliation(s)
- Syamak Farajikhah
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
| | - Joan M. Cabot
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania 7005, Australia
| | - Peter C. Innis
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility − Materials Node, Innovation Campus, University of Wollongong, New South Wales 2522, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania 7005, Australia
| | - Gordon Wallace
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility − Materials Node, Innovation Campus, University of Wollongong, New South Wales 2522, Australia
| |
Collapse
|
37
|
Biswas GC, Rana MM, Kazuhiro T, Suzuki H. A simple micropump based on a freeze-dried superabsorbent polymer for multiplex solution processing in disposable devices. ROYAL SOCIETY OPEN SCIENCE 2019; 6:182213. [PMID: 31032056 PMCID: PMC6458371 DOI: 10.1098/rsos.182213] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 02/27/2019] [Indexed: 06/09/2023]
Abstract
We describe a simple micropump for disposable microfluidic devices. The pump is constructed using a freeze-dried disc of a superabsorbent polymer (SAP). The disc absorbs a solution in a flow channel and swells upward in a pumping chamber. Despite the simple structure of this device, the rate of absorption remains constant and can be adjusted by changing the composition of the SAP, its size, the dimensions of the flow channel and the medium to be absorbed. The pumping action can be initiated by applying an electrical signal using a switchable hydrophobic valve. The integrated approach of the SAP pump and switchable valve could facilitate the automatic processing of many solutions required for bioassay.
Collapse
Affiliation(s)
- Gokul Chandra Biswas
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Md. Mohosin Rana
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Takekoshi Kazuhiro
- Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8675, Japan
| | - Hiroaki Suzuki
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| |
Collapse
|
38
|
Noiphung J, Laiwattanapaisal W. Multifunctional Paper-Based Analytical Device for In Situ Cultivation and Screening of Escherichia coli Infections. Sci Rep 2019; 9:1555. [PMID: 30733495 PMCID: PMC6367442 DOI: 10.1038/s41598-018-38159-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 12/20/2018] [Indexed: 01/09/2023] Open
Abstract
Point-of-care testing (POCT) for uropathogen detection and chemical screening has great benefits for the diagnosis of urinary tract infections (UTIs). The goal of this study was to develop a portable and inexpensive paper-based analytical device (PAD) for cultivating bacteria in situ and rapidly testing for nitrite on the same device. The PAD was fabricated using a wax printing technique to create a pattern on Whatman No. 1 filter paper, which was then combined with a cotton sheet to support bacterial growth. Nitrite detection was based on the principle of the Griess reaction, and a linear detection range of 0-1.6 mg/dL (R2 = 0.989) was obtained. Scanning electron microscopy (SEM) analysis demonstrated that the bacteria were able to grow and formed a cluster on the cellulose fibres within 2 hours. The enzyme β-glucuronidase, which is specifically produced by Escherichia coli, was able to convert the pre-immobilized 5-bromo-4-chloro-3-indolyl-β-D-glucuronide sodium salt (X-GlcA), a colourless substrate, generating a blue colour. Under optimum conditions, the proposed device allowed bacterial concentrations in the range of 104-107 colony forming units (CFU)/mL to be quantified within 6 hours. Moreover, the use of this device enables the identification of E. coli pathogens with selectivity in real urine samples. In conclusion, the PAD developed in this study for UTI screening provides a rapid, cost-effective diagnostic method for use in remote areas.
Collapse
Affiliation(s)
- Julaluk Noiphung
- Graduate Program in Clinical Biochemistry and Molecular Medicine, Faculty of Allied Health Sciences, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand
| | - Wanida Laiwattanapaisal
- Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand. .,Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
39
|
Dossi N, Toniolo R, Terzi F, Sdrigotti N, Tubaro F, Bontempelli G. A cotton thread fluidic device with a wall-jet pencil-drawn paper based dual electrode detector. Anal Chim Acta 2018; 1040:74-80. [DOI: 10.1016/j.aca.2018.06.061] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 06/21/2018] [Accepted: 06/22/2018] [Indexed: 10/28/2022]
|
40
|
Cabot JM, Macdonald NP, Phung SC, Breadmore MC, Paull B. Fibre-based electrofluidics on low cost versatile 3D printed platforms for solute delivery, separations and diagnostics; from small molecules to intact cells. Analyst 2018; 141:6422-6431. [PMID: 27786314 DOI: 10.1039/c6an01515h] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
A novel and effective fibre-based microfluidic methodology was developed to move and isolate charged solutes, biomolecules, and intact bacterial cells, based upon a novel multi-functional 3D printed supporting platform, with potential applications in the fields of microfluidics and biodiagnostics. Various on-fibre electrophoretic techniques are demonstrated to separate, pre-concentrate, move, split, or cut and collect the isolated zones of target solutes, including proteins and live bacterial cells. The use of knotting to link different fibre materials, and the unique ability of this approach to physically concentrate solutes in different locations are shown such that the concentrated solutes can be physically isolated and easily transferred to other fibres. Application of this novel fibre-based technique within a potential diagnostic platform for urinary tract infection is shown, together with the post-electrophoretic incubation of live bacterial cells, demonstrating the cell survival following on-fibre electrophoretic concentration.
Collapse
Affiliation(s)
- Joan M Cabot
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Niall P Macdonald
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Sui C Phung
- Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Michael C Breadmore
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Brett Paull
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| |
Collapse
|
41
|
Gaines M, Gonzalez-Guerrero MJ, Uchida K, Gomez FA. Microfluidic thread-based electrode system to detect glucose and acetylthiocholine. Electrophoresis 2018; 39:3082-3086. [PMID: 30232815 DOI: 10.1002/elps.201800348] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 09/05/2018] [Accepted: 09/11/2018] [Indexed: 11/07/2022]
Abstract
A reusable and simple to fabricate electrochemical sensor for the detection of glucose and acetylthiocholine using thread-based electrodes and nylon thread is described. The fabrication of the device consisted of two steps. First, three nylon-based electrodes (reference, working, and counter) were painted with one layer of conductive inks (silver and carbon ink, or silver/silver chloride ink). The electrodes were taped onto parafilm, and a piece of white nylon thread was wrapped around each electrode connecting the three electrodes. For the glucose system, a PBS solution containing glucose oxidase (GOx) (10 mg/mL), and potassium ferricyanide (K3 [Fe(CN)6 ]) (10 mg/mL) as mediator, was dried onto the thread, and increasing concentrations of glucose (0-15 mM) was added to the thread and measured by cyclic voltammetry (CV). The current output from the glucose oxidation was proportional to the concentration of glucose. For the second system, a solution of acetylcholinesterase (AChE) (0.08 U/mL) in PBS was added to the nylon thread, and increasing concentrations of acetylthiocholine (ATC) (0-9.84 mg/mL) was added and measured by CV. The current output from the oxidation of thiocholine (produced by AChE reacting with ATC) was proportional to the concentrations of ATC added to the thread. From both systems, a graph of current output versus substrate concentration was produced and fitted with a linear regression line that gave R2 values of 0.985 (GOX /glucose) and 0.995 (AChE/ATC).
Collapse
Affiliation(s)
- Michelle Gaines
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| | | | - Kathryn Uchida
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| | - Frank A Gomez
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| |
Collapse
|
42
|
Mousavi MPS, Ainla A, Tan EKW, K Abd El-Rahman M, Yoshida Y, Yuan L, Sigurslid HH, Arkan N, Yip MC, Abrahamsson CK, Homer-Vanniasinkam S, Whitesides GM. Ion sensing with thread-based potentiometric electrodes. LAB ON A CHIP 2018; 18:2279-2290. [PMID: 29987296 DOI: 10.1039/c8lc00352a] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Potentiometric sensing of ions with ion-selective electrodes (ISEs) is a powerful technique for selective and sensitive measurement of ions in complex matrices. The application of ISEs is generally limited to laboratory settings, because most commercially available ISEs and reference electrodes are large, delicate, and expensive, and are not suitable for point-of-use or point-of-care measurements. This work utilizes cotton thread as a substrate for fabrication of robust and miniaturized ISEs that are suitable for point-of-care or point-of-use applications. Thread-based ISEs selective for Cl-, K+, Na+, and Ca2+ were developed. The cation-selective ISEs were fabricated by coating the thread with a surfactant-free conductive ink (made of carbon black) and then coating the tip of the conductive thread with the ion-selective membrane. The Cl- ISE was fabricated by coating the thread with an Ag/AgCl ink. These sensors exhibited slopes (of electrical potential vs. log concentration of target ion), close to the theoretically-expected values, over four orders of magnitude in concentrations of ions. Because thread is mechanically strong, the thread-based electrodes can be used in multiple-use applications as well as single-use applications. Multiple thread-based sensors can be easily bundled together to fabricate a customized sensor for multiplexed ion-sensing. These electrodes require volumes of sample as low as 200 μL. The application of thread-based ISEs is demonstrated in the analysis of ions in soil, food, and dietary supplements (Cl- in soil/water slurry, K+ and Na+ in coconut water, and Ca2+ in a calcium supplement), and in detection of physiological electrolytes (K+ and Na+ in blood serum and urine, with sufficient accuracy for clinical diagnostics).
Collapse
Affiliation(s)
- Maral P S Mousavi
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Gaines M, Gonzalez‐Guerrero MJ, Uchida K, Gomez FA. A microfluidic glucose sensor incorporating a novel thread‐based electrode system. Electrophoresis 2018; 39:2131-2135. [DOI: 10.1002/elps.201800010] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 04/22/2018] [Accepted: 04/23/2018] [Indexed: 11/10/2022]
Affiliation(s)
- Michelle Gaines
- Department of Chemistry and Biochemistry California State University Los Angeles CA USA
| | | | - Kathryn Uchida
- Department of Chemistry and Biochemistry California State University Los Angeles CA USA
| | - Frank A. Gomez
- Department of Chemistry and Biochemistry California State University Los Angeles CA USA
| |
Collapse
|
44
|
Cabot JM, Breadmore MC, Paull B. Thread based electrofluidic platform for direct metabolite analysis in complex samples. Anal Chim Acta 2018; 1000:283-292. [DOI: 10.1016/j.aca.2017.10.029] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 10/19/2017] [Accepted: 10/22/2017] [Indexed: 11/25/2022]
|
45
|
Caetano F, Carneiro E, Agustini D, Figueiredo-Filho L, Banks C, Bergamini M, Marcolino-Junior L. Combination of electrochemical biosensor and textile threads: A microfluidic device for phenol determination in tap water. Biosens Bioelectron 2018; 99:382-388. [DOI: 10.1016/j.bios.2017.07.070] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 07/18/2017] [Accepted: 07/28/2017] [Indexed: 11/26/2022]
|
46
|
Agustini D, Bergamini MF, Marcolino-Junior LH. Tear glucose detection combining microfluidic thread based device, amperometric biosensor and microflow injection analysis. Biosens Bioelectron 2017; 98:161-167. [DOI: 10.1016/j.bios.2017.06.035] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Revised: 06/07/2017] [Accepted: 06/16/2017] [Indexed: 11/16/2022]
|
47
|
Carneiro EA, Agustini D, Figueiredo-Filho LCS, Banks CE, Marcolino-Junior LH, Bergamini MF. 3D-printed Microfluidic Device Based on Cotton Threads for Amperometric Estimation of Antioxidants in Wine Samples. ELECTROANAL 2017. [DOI: 10.1002/elan.201700579] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Emmanuelle A. Carneiro
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| | - Deonir Agustini
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| | | | - Craig E. Banks
- Faculty of Science and Engineering; Manchester Metropolitan University; Chester Street Manchester M1 5GD UK
| | - Luiz Humberto Marcolino-Junior
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| | - Márcio F. Bergamini
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química; Universidade Federal do Paraná (UFPR); CEP 81.531-980 Curitiba-PR Brazil
| |
Collapse
|
48
|
Bipolar electrochemiluminescence on thread: A new class of electroanalytical sensors. Biosens Bioelectron 2017; 94:335-343. [DOI: 10.1016/j.bios.2017.03.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 02/12/2017] [Accepted: 03/06/2017] [Indexed: 11/22/2022]
|
49
|
Agustini D, Bergamini MF, Marcolino-Junior LH. Characterization and optimization of low cost microfluidic thread based electroanalytical device for micro flow injection analysis. Anal Chim Acta 2017; 951:108-115. [DOI: 10.1016/j.aca.2016.11.046] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Accepted: 11/16/2016] [Indexed: 10/20/2022]
|
50
|
|