1
|
Jahnke HG, te Kamp V, Prönnecke C, Schmidt S, Azendorf R, Klupp B, Robitzki AA, Finke S. Novel Multiparametric Bioelectronic Measurement System for Monitoring Virus-Induced Alterations in Functional Neuronal Networks. BIOSENSORS 2024; 14:295. [PMID: 38920600 PMCID: PMC11202209 DOI: 10.3390/bios14060295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/29/2024] [Accepted: 06/03/2024] [Indexed: 06/27/2024]
Abstract
Development and optimisation of bioelectronic monitoring techniques like microelectrode array-based field potential measurement and impedance spectroscopy for the functional, label-free and non-invasive monitoring of in vitro neuronal networks is widely investigated in the field of biosensors. Thus, these techniques were individually used to demonstrate the capabilities of, e.g., detecting compound-induced toxicity in neuronal culture models. In contrast, extended application for investigating the effects of central nervous system infecting viruses are rarely described. In this context, we wanted to analyse the effect of herpesviruses on functional neuronal networks. Therefore, we developed a unique hybrid bioelectronic monitoring platform that allows for performing field potential monitoring and impedance spectroscopy on the same microelectrode. In the first step, a neuronal culture model based on primary hippocampal cells from neonatal rats was established with reproducible and stable synchronised electrophysiological network activity after 21 days of cultivation on microelectrode arrays. For a proof of concept, the pseudorabies model virus PrV Kaplan-ΔgG-GFP was applied and the effect on the neuronal networks was monitored by impedance spectroscopy and field potential measurement for 72 h in a multiparametric mode. Analysis of several bioelectronic parameters revealed a virus concentration-dependent degeneration of the neuronal network within 24-48 h, with a significant early change in electrophysiological activity, subsequently leading to a loss of activity and network synchronicity. In conclusion, we successfully developed a microelectrode array-based hybrid bioelectronic measurement platform for quantitative monitoring of pathologic effects of a herpesvirus on electrophysiological active neuronal networks.
Collapse
Affiliation(s)
- Heinz-Georg Jahnke
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, 04103 Leipzig, Germany (S.S.)
| | - Verena te Kamp
- Institute of Molecular Virology and Cell Biology, Friedrich-Loeffler-Institut, Südufer 10, 17493 Greifswald, Germany (B.K.)
| | - Christoph Prönnecke
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, 04103 Leipzig, Germany (S.S.)
| | - Sabine Schmidt
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, 04103 Leipzig, Germany (S.S.)
| | - Ronny Azendorf
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, 04103 Leipzig, Germany (S.S.)
| | - Barbara Klupp
- Institute of Molecular Virology and Cell Biology, Friedrich-Loeffler-Institut, Südufer 10, 17493 Greifswald, Germany (B.K.)
| | - Andrea A. Robitzki
- Division Management for Biology, Chemistry and Process Engineering, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Stefan Finke
- Institute of Molecular Virology and Cell Biology, Friedrich-Loeffler-Institut, Südufer 10, 17493 Greifswald, Germany (B.K.)
| |
Collapse
|
2
|
Schmidt S, Li W, Schubert M, Binnewerg B, Prönnecke C, Zitzmann FD, Bulst M, Wegner S, Meier M, Guan K, Jahnke HG. Novel high-dense microelectrode array based multimodal bioelectronic monitoring system for cardiac arrhythmia re-entry analysis. Biosens Bioelectron 2024; 252:116120. [PMID: 38394704 DOI: 10.1016/j.bios.2024.116120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/26/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024]
Abstract
In recent decades, significant progress has been made in the treatment of heart diseases, particularly in the field of personalized medicine. Despite the development of genetic tests, phenotyping and risk stratification are performed based on clinical findings and invasive in vivo techniques, such as stimulation conduction mapping techniques and programmed ventricular pacing. Consequently, label-free non-invasive in vitro functional analysis systems are urgently needed for more accurate and effective in vitro risk stratification, model-based therapy planning, and clinical safety profile evaluation of drugs. To overcome these limitations, a novel multilayer high-density microelectrode array (HD-MEA), with an optimized configuration of 512 sensing and 4 pacing electrodes on a sensor area of 100 mm2, was developed for the bioelectronic detection of re-entry arrhythmia patterns. Together with a co-developed front-end, we monitored label-free and in parallel cardiac electrophysiology based on field potential monitoring and mechanical contraction using impedance spectroscopy at the same microelectrode. In proof of principle experiments, human induced pluripotent stem cell (hiPS)-derived cardiomyocytes were cultured on HD-MEAs and used to demonstrate the sensitive quantification of contraction strength modulation by cardioactive drugs such as blebbistatin (IC50 = 4.2 μM), omecamtiv and levosimendan. Strikingly, arrhythmia-typical rotor patterns (re-entry) can be induced by optimized electrical stimulation sequences and detected with high spatial resolution. Therefore, we provide a novel cardiac re-entry analysis system as a promising reference point for diagnostic approaches based on in vitro assays using patient-specific hiPS-derived cardiomyocytes.
Collapse
Affiliation(s)
- Sabine Schmidt
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany
| | - Wener Li
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Mario Schubert
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Björn Binnewerg
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Christoph Prönnecke
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany
| | - Franziska D Zitzmann
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany
| | - Martin Bulst
- Sciospec Scientific Instruments GmbH, Leipziger Str. 43b, D-04828, Bennewitz, Germany
| | - Sebastian Wegner
- Sciospec Scientific Instruments GmbH, Leipziger Str. 43b, D-04828, Bennewitz, Germany
| | - Matthias Meier
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany; Helmholtz Pioneer Campus, Helmholtz Zentrum Munich, Neuherberg, Germany
| | - Kaomei Guan
- Institute of Pharmacology and Toxicology, Carl Gustav Carus Medical Faculty, Technical University Dresden, Fetscherstraße 74, D-01307, Dresden, Germany
| | - Heinz-Georg Jahnke
- Centre for Biotechnology and Biomedicine, Biochemical Cell Technology, Leipzig University, Deutscher Platz 5, D-04103, Leipzig, Germany.
| |
Collapse
|
3
|
Stoppini L, Heuschkel MO, Loussert-Fonta C, Gomez Baisac L, Roux A. Versatile micro-electrode array to monitor human iPSC derived 3D neural tissues at air-liquid interface. Front Cell Neurosci 2024; 18:1389580. [PMID: 38784710 PMCID: PMC11112036 DOI: 10.3389/fncel.2024.1389580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 04/02/2024] [Indexed: 05/25/2024] Open
Abstract
Engineered 3D neural tissues made of neurons and glial cells derived from human induced pluripotent stem cells (hiPSC) are among the most promising tools in drug discovery and neurotoxicology. They represent a cheaper, faster, and more ethical alternative to in vivo animal testing that will likely close the gap between in vitro animal models and human clinical trials. Micro-Electrode Array (MEA) technology is known to provide an assessment of compound effects on neural 2D cell cultures and acute tissue preparations by real-time, non-invasive, and long-lasting electrophysiological monitoring of spontaneous and evoked neuronal activity. Nevertheless, the use of engineered 3D neural tissues in combination with MEA biochips still involves series of constraints, such as drastically limited diffusion of oxygen and nutrients within tissues mainly due to the lack of vascularization. Therefore, 3D neural tissues are extremely sensitive to experimental conditions and require an adequately designed interface that provides optimal tissue survival conditions. A well-suited technique to overcome this issue is the combination of the Air-Liquid Interface (ALI) tissue culture method with the MEA technology. We have developed a full 3D neural tissue culture process and a data acquisition system composed of high-end electronics and novel MEA biochips based on porous, flexible, thin-film membranes integrating recording electrodes, named as "Strip-MEA," to allow the maintenance of an ALI around the 3D neural tissues. The main motivation of the porous MEA biochips development was the possibility to monitor and to study the electrical activity of 3D neural tissues under different recording configurations, (i) the Strip-MEA can be placed below a tissue, (ii) or by taking advantage of the ALI, be directly placed on top of the tissue, or finally, (iii) it can be embedded into a larger neural tissue generated by the fusion of two (or more) tissues placed on both sides of the Strip-MEA allowing the recording from its inner part. This paper presents the recording and analyses of spontaneous activity from the three positioning configurations of the Strip-MEAs. Obtained results are discussed with the perspective of developing in vitro models of brain diseases and/or impairment of neural network functioning.
Collapse
Affiliation(s)
| | | | | | | | - Adrien Roux
- Tissue Engineering Laboratory, HEPIA HES-SO University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland
| |
Collapse
|
4
|
Ishibashi Y, Nagafuku N, Kinoshita K, Okamura A, Shirakawa T, Suzuki I. Verification of the seizure liability of compounds based on their in vitro functional activity in cultured rat cortical neurons and co-cultured human iPSC-derived neurons with astrocytes and in vivo extrapolation to cerebrospinal fluid concentration. Toxicol Appl Pharmacol 2023; 476:116675. [PMID: 37661062 DOI: 10.1016/j.taap.2023.116675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 08/26/2023] [Accepted: 08/30/2023] [Indexed: 09/05/2023]
Abstract
Methodical screening of safe and efficient drug candidate compounds is crucial for drug development. A high-throughput and accurate compound evaluation method targeting the central nervous system can be developed using in vitro neural networks. In particular, an evaluation system based on a human-derived neural network that can act as an alternative to animal experiments is desirable to avoid interspecific differences. A microelectrode array (MEA) is one such evaluation system, and can measure in vitro neural activity; however, studies on compound evaluation criteria and in vitro to in vivo extrapolation are scarce. In this study, we identified the parameters that can eliminate the effects of solvents from neural activity data obtained using MEA allow for accurate compound evaluation. Additionally, we resolved the issue associated with compound evaluation criteria during MEA using principal component analysis by considering the neuronal activity exceeding standard deviation (SD) of the solvent as indicator of seizurogenic potential. Overall, 10 seizurogenic compounds and three negative controls were assessed using MEA-based co-cultured human-induced pluripotent stem cell-derived neurons and astrocytes, and primary rat cortical neurons. In addition, we determined rat cerebrospinal fluid (CSF) concentrations during tremor and convulsion in response to exposure to test compounds. To characterize the in vitro to in vivo extrapolation and species differences, we compared the concentrations at which neuronal activity exceeding the SD range of the solvent was detectable using the MEA system and rat CSF concentration.
Collapse
Affiliation(s)
- Y Ishibashi
- Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi 982-8577, Japan
| | - N Nagafuku
- Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi 982-8577, Japan
| | - K Kinoshita
- Drug Safety Research Labs, Astellas Pharma Inc., 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - A Okamura
- Drug Safety Research Labs, Astellas Pharma Inc., 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - T Shirakawa
- Drug Safety Research Labs, Astellas Pharma Inc., 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - I Suzuki
- Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi 982-8577, Japan.
| |
Collapse
|
5
|
Kim JW, Choi YY, Park SH, Ha JH, Lee HU, Kang T, Sun W, Chung BG. Microfluidic electrode array chip for electrical stimulation-mediated axonal regeneration. LAB ON A CHIP 2022; 22:2122-2130. [PMID: 35388823 DOI: 10.1039/d1lc01158h] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The precise manipulation of the neural stem cell (NSC)-derived neural differentiation is still challenging, and there is a technological barrier to regulate the axonal regeneration in a controlled manner. Here, we developed a microfluidic chip integrated with a microelectrode array as an axonal guidance platform. The microfluidic electrode array chip consisted of two compartments and a bridge microchannel that could isolate and guide the axons. We demonstrated that the NSCs were largely differentiated into neural cells as the electric field was applied to the microfluidic electrode array chip. We also confirmed the synergistic effects of the electrical stimulation (ES) and neurotrophic factor (NF) on axonal outgrowth. This microfluidic electrode array chip can serve as a central nervous system (CNS) model for axonal injury and regeneration. Therefore, it could be a potentially powerful tool for an in vitro model of the axonal regeneration.
Collapse
Affiliation(s)
- Ji Woon Kim
- Department of Biomedical Engineering, Sogang University, Seoul, Korea
| | - Yoon Young Choi
- Institute of Integrated Biotechnology, Sogang University, Seoul, Korea
| | - Si-Hyung Park
- Department of Anatomy, Korea University College of Medicine, Seoul, Korea.
| | - Jang Ho Ha
- Department of Mechanical Engineering, Sogang University, Seoul, Korea.
| | - Hee Uk Lee
- Department of Mechanical Engineering, Sogang University, Seoul, Korea.
| | - Taewook Kang
- Institute of Integrated Biotechnology, Sogang University, Seoul, Korea
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul, Korea
| | - Woong Sun
- Department of Anatomy, Korea University College of Medicine, Seoul, Korea.
| | - Bong Geun Chung
- Institute of Integrated Biotechnology, Sogang University, Seoul, Korea
- Department of Mechanical Engineering, Sogang University, Seoul, Korea.
| |
Collapse
|
6
|
Schmidt S, Haensch T, Frank R, Jahnke HG, Robitzki AA. Reactive Sputtered Silicon Nitride as an Alternative Passivation Layer for Microelectrode Arrays in Sensitive Bioimpedimetric Cell Monitoring. ACS APPLIED MATERIALS & INTERFACES 2021; 13:59185-59195. [PMID: 34851082 DOI: 10.1021/acsami.1c14981] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Microelectrode arrays (MEAs) are widely used to study the behavior of cells noninvasively and in real time. While the design of MEAs focuses mainly on the electrode material or its application-dependent modification, the passivation layer, which is crucial to define the electrode area and to insulate the conducting paths, remains largely unnoticed. Because often most cells are in direct contact with the passivation layer rather than the electrode material, biocompatible photoresists such as SU-8 are almost exclusively used. However, SU-8 is not without limitations in terms of optical transmission, optimal cell support, or compatibility within polymer-based microfluidic lab on chip systems. Here, we established a silicon nitride (SiN) passivation by physical vapor deposition (PVD), which was optimized and evaluated for impedance spectroscopy-based monitoring of cells. Surface characteristics, biocompatibility, and electrical insulation capability were investigated and compared to SU8 in detail. To investigate the influence of the SiN passivation on the impedimetric analysis of cells, HEK-293 A and MCF-7 were chosen as adherent cell models and measured on microelectrodes of 50-200 μm in diameter. The results clearly revealed an overall suitability of SiN as alternative passivation. While for the smallest electrode size a cell line dependent comparable or slightly decreased cell signal could be observed in comparison with SU-8, a significant higher cell signal was observed for microelectrodes larger than 50 μm in diameter. Furthermore, a high suitability for the bonding of PEGDA and PDMS microfluidic structures on the SiN passivation layer without any leakage could be demonstrated.
Collapse
Affiliation(s)
- Sabine Schmidt
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Tobias Haensch
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Ronny Frank
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Heinz-Georg Jahnke
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Andrea A Robitzki
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| |
Collapse
|
7
|
Pandanaboina SC, RanguMagar AB, Sharma KD, Chhetri BP, Parnell CM, Xie JY, Srivatsan M, Ghosh A. Functionalized Nanocellulose Drives Neural Stem Cells toward Neuronal Differentiation. J Funct Biomater 2021; 12:64. [PMID: 34842752 PMCID: PMC8628960 DOI: 10.3390/jfb12040064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/10/2021] [Accepted: 11/13/2021] [Indexed: 11/23/2022] Open
Abstract
Transplantation of differentiated and fully functional neurons may be a better therapeutic option for the cure of neurodegenerative disorders and brain injuries than direct grafting of neural stem cells (NSCs) that are potentially tumorigenic. However, the differentiation of NSCs into a large population of neurons has been a challenge. Nanomaterials have been widely used as substrates to manipulate cell behavior due to their nano-size, excellent physicochemical properties, ease of synthesis, and versatility in surface functionalization. Nanomaterial-based scaffolds and synthetic polymers have been fabricated with topology resembling the micro-environment of the extracellular matrix. Nanocellulose materials are gaining attention because of their availability, biocompatibility, biodegradability and bioactivity, and affordable cost. We evaluated the role of nanocellulose with different linkage and surface features in promoting neuronal differentiation. Nanocellulose coupled with lysine molecules (CNC-Lys) provided positive charges that helped the cells to attach. Embryonic rat NSCs were differentiated on the CNC-Lys surface for up to three weeks. By the end of the three weeks of in vitro culture, 87% of the cells had attached to the CNC-Lys surface and more than half of the NSCs had differentiated into functional neurons, expressing endogenous glutamate, generating electrical activity and action potentials recorded by the multi-electrode array.
Collapse
Affiliation(s)
- Sahitya Chetan Pandanaboina
- Department of Biological Sciences and Arkansas Biosciences Institute, Arkansas State University, Jonesboro, AR 72401, USA; (S.C.P.); (K.D.S.)
| | - Ambar B. RanguMagar
- Department of Chemistry, University of Arkansas at Little Rock, Little Rock, AR 72204, USA; (A.B.R.); (B.P.C.); (C.M.P.)
| | - Krishna D. Sharma
- Department of Biological Sciences and Arkansas Biosciences Institute, Arkansas State University, Jonesboro, AR 72401, USA; (S.C.P.); (K.D.S.)
| | - Bijay P. Chhetri
- Department of Chemistry, University of Arkansas at Little Rock, Little Rock, AR 72204, USA; (A.B.R.); (B.P.C.); (C.M.P.)
| | - Charlette M. Parnell
- Department of Chemistry, University of Arkansas at Little Rock, Little Rock, AR 72204, USA; (A.B.R.); (B.P.C.); (C.M.P.)
| | - Jennifer Yanhua Xie
- Department of Basic Sciences, New York Institute of Technology College of Osteopathic Medicine, Arkansas State University, Jonesboro, AR 72401, USA
| | - Malathi Srivatsan
- Department of Biological Sciences and Arkansas Biosciences Institute, Arkansas State University, Jonesboro, AR 72401, USA; (S.C.P.); (K.D.S.)
| | - Anindya Ghosh
- Department of Chemistry, University of Arkansas at Little Rock, Little Rock, AR 72204, USA; (A.B.R.); (B.P.C.); (C.M.P.)
| |
Collapse
|
8
|
Ishibashi Y, Odawara A, Kinoshita K, Okamura A, Shirakawa T, Suzuki I. Principal Component Analysis to Distinguish Seizure Liability of Drugs in Human iPS Cell-Derived Neurons. Toxicol Sci 2021; 184:265-275. [PMID: 34570236 DOI: 10.1093/toxsci/kfab116] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Screening for drug discovery targeting the central nervous system requires the establishment of efficient and highly accurate toxicity test methods that can reduce costs and time while maintaining high throughput using the function of an in vitro neural network. In particular, an evaluation system using a human-derived neural network is desirable in terms of species difference. Despite the attention the microelectrode array (MEA) is attracting among the evaluation systems that can measure in vitro neural activity, an effective analysis method for evaluation of toxicity and mechanism of action has not yet been established. Here we established analytical parameters and multivariate analysis method capable of detecting seizure liability of drugs using MEA measurement of human iPS cell-derived neurons. Using the spike time series data of all drugs, we established periodicity as a new analytical parameter. Periodicity has facilitated the detection of responses to seizurogenic drugs, previously difficult to detect with conventional analytical parameters. By constructing a multivariate analytical method that identifies a parameter set that achieves an arbitrary condition, we found that the parameter set comprising total spikes, maximum frequency, inter maximum frequency interval, coefficient of variance of inter maximum frequency interval, and periodicity can uniformly detect the seizure liability of seizurogenic drugs with different mechanisms of action. Seizurogenic drugs were suggested to increase the regularity of the network burst in MEA measurements in human iPS cell-derived neurons.
Collapse
Affiliation(s)
- Y Ishibashi
- Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi, 982-8577, Japan
| | - A Odawara
- Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi, 982-8577, Japan
| | - K Kinoshita
- Drug Safety Research Labs, Astellas Pharma Inc, 21 Miyukigaoka, Tsukuba, Ibaraki, 305-0841, Japan
| | - A Okamura
- Drug Safety Research Labs, Astellas Pharma Inc, 21 Miyukigaoka, Tsukuba, Ibaraki, 305-0841, Japan
| | - T Shirakawa
- Drug Safety Research Labs, Astellas Pharma Inc, 21 Miyukigaoka, Tsukuba, Ibaraki, 305-0841, Japan
| | - I Suzuki
- Department of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama Kasumicho, Taihaku-ku, Sendai, Miyagi, 982-8577, Japan
| |
Collapse
|
9
|
Abstract
Engineered human mini-brains, made possible by knowledge from the convergence of precision microengineering and cell biology, permit systematic studies of complex neurological processes and of pathogenesis beyond what can be done with animal models. By culturing human brain cells with physiological microenvironmental cues, human mini-brain models reconstitute the arrangement of structural tissues and some of the complex biological functions of the human brain. In this Review, we highlight the most significant developments that have led to microphysiological human mini-brain models. We introduce the history of mini-brain development, review methods for creating mini-brain models in static conditions, and discuss relevant state-of-the-art dynamic cell-culture systems. We also review human mini-brain models that reconstruct aspects of major neurological disorders under static or dynamic conditions. Engineered human mini-brains will contribute to advancing the study of the physiology and aetiology of neurological disorders, and to the development of personalized medicines for them.
Collapse
|
10
|
Characterization and application of electrically active neuronal networks established from human induced pluripotent stem cell-derived neural progenitor cells for neurotoxicity evaluation. Stem Cell Res 2020; 45:101761. [PMID: 32244191 DOI: 10.1016/j.scr.2020.101761] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 02/20/2020] [Accepted: 03/05/2020] [Indexed: 12/13/2022] Open
Abstract
Neurotoxicity is mediated by a variety of modes-of-actions leading to disturbance of neuronal function. In order to screen larger numbers of compounds for their neurotoxic potential, in vitro functional neuronal networks (NN) might be helpful tools. We established and characterized human NN (hNN) from hiPSC-derived neural progenitor cells by comparing hNN formation with two different differentiation media: in presence (CINDA) and absence (neural differentiation medium (NDM)) of maturation-supporting factors. As a NN control we included differentiating rat NN (rNN) in the study. Gene/protein expression and electrical activity from in vitro developing NN were assessed at multiple time points. Transcriptomes of 5, 14 and 28 days in vitro CINDA-grown hNN were compared to gene expression profiles of in vivo human developing brains. Molecular expression analyses as well as measures of electrical activity indicate that NN mature into neurons of different subtypes and astrocytes over time. In contrast to rNN, hNN are less electrically active within the same period of differentiation time, yet hNN grown in CINDA medium develop higher firing rates than hNN without supplements. Challenge of NN with neuronal receptor stimulators and inhibitors demonstrate presence of inhibitory, GABAergic neurons, whereas glutamatergic responses are limited. hiPSC-derived GABAergic hNN grown in CINDA medium might be a useful tool as part of an in vitro battery for assessing neurotoxicity.
Collapse
|
11
|
Neural In Vitro Models for Studying Substances Acting on the Central Nervous System. Handb Exp Pharmacol 2020; 265:111-141. [PMID: 32594299 DOI: 10.1007/164_2020_367] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Animal models have been greatly contributing to our understanding of physiology, mechanisms of diseases, and toxicity. Yet, their limitations due to, e.g., interspecies variation are reflected in the high number of drug attrition rates, especially in central nervous system (CNS) diseases. Therefore, human-based neural in vitro models for studying safety and efficacy of substances acting on the CNS are needed. Human iPSC-derived cells offer such a platform with the unique advantage of reproducing the "human context" in vitro by preserving the genetic and molecular phenotype of their donors. Guiding the differentiation of hiPSC into cells of the nervous system and combining them in a 2D or 3D format allows to obtain complex models suitable for investigating neurotoxicity or brain-related diseases with patient-derived cells. This chapter will give an overview over stem cell-based human 2D neuronal and mixed neuronal/astrocyte models, in vitro cultures of microglia, as well as CNS disease models and considers new developments in the field, more specifically the use of brain organoids and 3D bioprinted in vitro models for safety and efficacy evaluation.
Collapse
|
12
|
Miccoli B, Lopez CM, Goikoetxea E, Putzeys J, Sekeri M, Krylychkina O, Chang SW, Firrincieli A, Andrei A, Reumers V, Braeken D. High-Density Electrical Recording and Impedance Imaging With a Multi-Modal CMOS Multi-Electrode Array Chip. Front Neurosci 2019; 13:641. [PMID: 31293372 PMCID: PMC6603149 DOI: 10.3389/fnins.2019.00641] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 06/04/2019] [Indexed: 01/11/2023] Open
Abstract
Multi-electrode arrays, both active or passive, emerged as ideal technologies to unveil intricated electrophysiological dynamics of cells and tissues. Active MEAs, designed using complementary metal oxide semiconductor technology (CMOS), stand over passive devices thanks to the possibility of achieving single-cell resolution, the reduced electrode size, the reduced crosstalk and the higher functionality and portability. Nevertheless, most of the reported CMOS MEA systems mainly rely on a single operational modality, which strongly hampers the applicability range of a single device. This can be a limiting factor considering that most biological and electrophysiological dynamics are often based on the synergy of multiple and complex mechanisms acting from different angles on the same phenomena. Here, we designed a CMOS MEA chip with 16,384 titanium nitride electrodes, 6 independent operational modalities and 1,024 parallel recording channels for neuro-electrophysiological studies. Sixteen independent active areas are patterned on the chip surface forming a 4 × 4 matrix, each one including 1,024 electrodes. Electrodes of four different sizes are present on the chip surface, ranging from 2.5 × 3.5 μm2 up to 11 × 11.0 μm2, with 15 μm pitch. In this paper, we exploited the impedance monitoring and voltage recording modalities not only to monitor the growth and development of primary rat hippocampal neurons, but also to assess their electrophysiological activity over time showing a mean spike amplitude of 144.8 ± 84.6 μV. Fixed frequency (1 kHz) and high sampling rate (30 kHz) impedance measurements were used to evaluate the cellular adhesion and growth on the chip surface. Thanks to the high-density configuration of the electrodes, as well as their dimension and pitch, the chip can appreciate the evolutions of the cell culture morphology starting from the moment of the seeding up to mature culture conditions. The measurements were confirmed by fluorescent staining. The effect of the different electrode sizes on the spike amplitudes and noise were also discussed. The multi-modality of the presented CMOS MEA allows for the simultaneous assessment of different physiological properties of the cultured neurons. Therefore, it can pave the way both to answer complex fundamental neuroscience questions as well as to aid the current drug-development paradigm.
Collapse
|
13
|
Ylä-Outinen L, Tanskanen JMA, Kapucu FE, Hyysalo A, Hyttinen JAK, Narkilahti S. Advances in Human Stem Cell-Derived Neuronal Cell Culturing and Analysis. ADVANCES IN NEUROBIOLOGY 2019; 22:299-329. [DOI: 10.1007/978-3-030-11135-9_13] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
14
|
Grainger AI, King MC, Nagel DA, Parri HR, Coleman MD, Hill EJ. In vitro Models for Seizure-Liability Testing Using Induced Pluripotent Stem Cells. Front Neurosci 2018; 12:590. [PMID: 30233290 PMCID: PMC6127295 DOI: 10.3389/fnins.2018.00590] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 08/06/2018] [Indexed: 12/14/2022] Open
Abstract
The brain is the most complex organ in the body, controlling our highest functions, as well as regulating myriad processes which incorporate the entire physiological system. The effects of prospective therapeutic entities on the brain and central nervous system (CNS) may potentially cause significant injury, hence, CNS toxicity testing forms part of the “core battery” of safety pharmacology studies. Drug-induced seizure is a major reason for compound attrition during drug development. Currently, the rat ex vivo hippocampal slice assay is the standard option for seizure-liability studies, followed by primary rodent cultures. These models can respond to diverse agents and predict seizure outcome, yet controversy over the relevance, efficacy, and cost of these animal-based methods has led to interest in the development of human-derived models. Existing platforms often utilize rodents, and so lack human receptors and other drug targets, which may produce misleading data, with difficulties in inter-species extrapolation. Current electrophysiological approaches are typically used in a low-throughput capacity and network function may be overlooked. Human-derived induced pluripotent stem cells (iPSCs) are a promising avenue for neurotoxicity testing, increasingly utilized in drug screening and disease modeling. Furthermore, the combination of iPSC-derived models with functional techniques such as multi-electrode array (MEA) analysis can provide information on neuronal network function, with increased sensitivity to neurotoxic effects which disrupt different pathways. The use of an in vitro human iPSC-derived neural model for neurotoxicity studies, combined with high-throughput techniques such as MEA recordings, could be a suitable addition to existing pre-clinical seizure-liability testing strategies.
Collapse
Affiliation(s)
| | - Marianne C King
- Life and Health Sciences, Aston University, Birmingham, United Kingdom
| | - David A Nagel
- Life and Health Sciences, Aston University, Birmingham, United Kingdom
| | - H Rheinallt Parri
- Life and Health Sciences, Aston University, Birmingham, United Kingdom
| | - Michael D Coleman
- Life and Health Sciences, Aston University, Birmingham, United Kingdom
| | - Eric J Hill
- Life and Health Sciences, Aston University, Birmingham, United Kingdom
| |
Collapse
|