Xiong J, Tian L, Shen X, Huang C. Comparison of the applicability of electromembrane extraction and liquid-phase microextraction for extraction of non-polar basic drugs from different biological samples: Using clozapine as the model analyte. J Sep Sci 2024; 47:e2300745. [PMID: 38356226 DOI: 10.1002/jssc.202300745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 01/10/2024] [Accepted: 01/24/2024] [Indexed: 02/16/2024]
Abstract
Understanding and comparing the applicability of electromembrane extraction (EME) and liquid-phase microextraction (LPME) is crucial for selecting an appropriate microextraction approach. In this work, EME and LPME based on supported liquid membranes were compared using biological samples, including whole blood, urine, saliva, and liver tissue. After optimization, efficient EME and LPME of clozapine from four biological samples were achieved. EME provided higher recovery and faster mass transfer for blood and liver tissue than LPME. These advantages were attributed to the electric field disrupting clozapine binding to interfering substances. For urine and saliva, EME demonstrated similar recoveries while achieving faster mass transfer rates. Finally, efficient EME and LPME were validated and evaluated combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The coefficient of determination of all methods was greater than 0.999, and all methods showed acceptable reproducibility (≤14%), accuracy (90%-110%), and matrix effect (85%-112%). For liver and blood with high viscosity and complex matrices, EME-LC-MS/MS provided better sensitivity than LPME-LC-MS/MS. The above results indicated that both EME and LPME could be used to isolate non-polar basic drugs from different biological samples, although EME demonstrated higher recovery rates for liver tissue and blood.
Collapse
Affiliation(s)
- Jianhua Xiong
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan, China
| | - Linxin Tian
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan, China
| | - Xiantao Shen
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Huazhong University of Science and Technology, Wuhan, China
| | - Chuixiu Huang
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
2
|
Schüller M, Hansen FA, Pedersen-Bjergaard S. Extraction performance of electromembrane extraction and liquid-phase microextraction in prototype equipment. J Chromatogr A 2023; 1710:464440. [PMID: 37832461 DOI: 10.1016/j.chroma.2023.464440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/05/2023] [Accepted: 10/08/2023] [Indexed: 10/15/2023]
Abstract
In this comparative study, the performance of liquid-phase microextraction and electromembrane extraction in prototype equipment was evaluated for extraction of ninety basic substances from plasma. Using a commercial EME device based on conductive vials enabled a standardized and comprehensive comparison between the two methods. Extractions were performed from a pH-adjusted donor solution, across an organic liquid membrane immobilized in a porous polypropylene membrane, and into an acidic acceptor solution. In LPME, dodecyl acetate was used as the extraction solvent, while 2-nitrophenyl octyl ether was used for EME with an electric field applied across the system. To assess the extraction performance, extraction recovery plots and extraction time curves were constructed and analyzed. These plots provided insights into the efficiency and effectiveness of LPME and EME, allowing users to make better decisions about the most suitable method for a specific bioanalytical application. Both LPME and EME were effective for substances with 2.0 < log P < 4.0, with EME showing faster extraction kinetics. Small (200 µL) and large vials (600 µL) were compared, showing that smaller vials improved kinetics markedly in both techniques. Carrier-mediated extraction showed improved performance for analytes with log P < 2 in EME, however, with some limitations due to system instability. This is, to our knowledge, the first time LPME was performed in the commercial vial-based equipment. An evaluation of vial-based LPME investigating linearity, precision, accuracy, and matrix effects showed promising results. These findings contribute to a general understanding of the performance differences in vial-based LPME and EME.
Collapse
Affiliation(s)
- Maria Schüller
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark.
| |
Collapse
|
3
|
Halevas E, Kokotidou C, Zaimai E, Moschona A, Lialiaris E, Mitraki A, Lialiaris T, Pantazaki A. Evaluation of the Hemocompatibility and Anticancer Potential of Poly( ε-Caprolactone) and Poly(3-Hydroxybutyrate) Microcarriers with Encapsulated Chrysin. Pharmaceutics 2021; 13:109. [PMID: 33467090 PMCID: PMC7831015 DOI: 10.3390/pharmaceutics13010109] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 01/12/2021] [Accepted: 01/14/2021] [Indexed: 01/18/2023] Open
Abstract
In this work, novel chrysin-loaded poly(ε-caprolactone) and poly(3-hydroxybutyrate) microcarriers were synthesized according to a modified oil-in-water single emulsion/solvent evaporation method, utilizing poly(vinyl alcohol) surfactant as stabilizer and dispersing agent for the emulsification, and were evaluated for their physico-chemical and morphological properties, loading capacity and entrapment efficiency and in vitro release of their load. The findings suggest that the novel micro-formulations possess a spherical and relatively wrinkled structure with sizes ranging between 2.4 and 24.7 µm and a highly negative surface charge with z-potential values between (-18.1)-(-14.1) mV. The entrapment efficiency of chrysin in the poly(ε-caprolactone) and poly(3-hydroxybutyrate) microcarriers was estimated to be 58.10% and 43.63%, whereas the loading capacity was found to be 3.79% and 15.85%, respectively. The average release percentage of chrysin was estimated to be 23.10% and 18.01%, respectively. The novel micromaterials were further biologically evaluated for their hemolytic activity through hemocompatibility studies over a range of hematological parameters and cytoxicity against the epithelial human breast cancer cell line MDA-MB 231. The poly(ε-caprolactone) and poly(3-hydroxybutyrate) microcarriers reached an IC50 value with an encapsulated chrysin content of 149.19 µM and 312.18 µM, respectively, and showed sufficient blood compatibility displaying significantly low (up to 2%) hemolytic percentages at concentrations between 5 and 500 µg·mL-1.
Collapse
Affiliation(s)
- Eleftherios Halevas
- Institute of Biosciences & Applications, National Centre for Scientific Research “Demokritos”, 15310 Athens, Greece
- Laboratory of Biochemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| | - Chrysoula Kokotidou
- Department of Materials Science and Technology, University of Crete, Voutes Campus, 70013 Heraklion, Greece; (C.K.); (A.M.)
- Institute for Electronic Structure and Laser FORTH, N. Plastira 100, 70013 Heraklion, Greece
| | - Elda Zaimai
- Laboratory of Biochemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| | - Alexandra Moschona
- Laboratory of Organic Chemistry, Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
- Laboratory of Natural Resources and Renewable Energies, Chemical Process and Energy Resources Institute, Centre for Research and Technology-Hellas (CERTH), 6th km Harilaou-Thermis, 57001 Thermi, Greece
| | - Efstratios Lialiaris
- Laboratory of Genetics, Medical School, Democritus University of Thrace, 68100 Alexandroupolis, Greece; (E.L.); (T.L.)
| | - Anna Mitraki
- Department of Materials Science and Technology, University of Crete, Voutes Campus, 70013 Heraklion, Greece; (C.K.); (A.M.)
- Institute for Electronic Structure and Laser FORTH, N. Plastira 100, 70013 Heraklion, Greece
| | - Theodore Lialiaris
- Laboratory of Genetics, Medical School, Democritus University of Thrace, 68100 Alexandroupolis, Greece; (E.L.); (T.L.)
| | - Anastasia Pantazaki
- Laboratory of Biochemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| |
Collapse
|
4
|
Wu S, Zhu R, Dong Y, Huang C, Shen X. Electromembrane extraction of barbiturates using tributyl phosphate as an efficient supported liquid membrane. Anal Chim Acta 2020; 1129:118-125. [DOI: 10.1016/j.aca.2020.07.040] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 07/11/2020] [Accepted: 07/15/2020] [Indexed: 01/17/2023]
|
5
|
Restan MS, Skjærvø Ø, Martinsen ØG, Pedersen-Bjergaard S. Towards exhaustive electromembrane extraction under stagnant conditions. Anal Chim Acta 2020; 1104:1-9. [PMID: 32106938 DOI: 10.1016/j.aca.2020.01.058] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 01/22/2020] [Accepted: 01/27/2020] [Indexed: 02/06/2023]
Abstract
Electromembrane extraction (EME) in small, stagnant and chip-like devices has the potential for future in-field operation. Literature briefly discuss such systems, but performance suffered from evaporative losses of sample and acceptor. To address this, the current paper reports electromembrane extraction (EME) of five basic drugs (model analytes) from aqueous buffer solutions and whole blood samples under stagnant conditions in a completely closed system. A laboratory-made polyoxymethylene (POM) well plate served as compartment for the sample solution, while a commercially available well filter plate was used to immobilize 2-nitrophenyl octyl ether (NPOE) as supported liquid membrane (SLM) and as closed compartment for the acceptor solution. Major design parameters (sample compartment and electrode geometry) and operational parameters (sample volume, voltage and extraction time) were investigated and optimized. Electrode geometry was not very critical, but extraction efficiency increased with decreasing sample volume. Extraction from 50 μL aqueous buffer solution for 60 min and with a voltage of 75 V was considered exhaustive (sample was depleted), with recoveries ranging between 75% and 87% for loperamide, haloperidol, methadone, nortriptyline, and pethidine (RSD: 2-12%). Extraction from whole blood samples under optimized conditions yielded slightly lower recoveries, ranging between 57 and 96% (RSD: 3-12%). Stagnant EME was evaluated in combination with liquid chromatography-mass spectrometry (LC-MS) as a highly specific instrumental method, and provided evaluation data on methadone from blood samples in accordance with regulatory requirements (LOD: 0.4 ng/mL, LOQ: 1.4 ng/mL, RSD: 6-20%). This work has improved upon the design of stagnant EME, moving it further towards a viable in-field operation device.
Collapse
Affiliation(s)
- Magnus Saed Restan
- Department of Pharmacy, University of Oslo, P.O. Box 1068, Blindern, 0316, Oslo, Norway
| | - Øystein Skjærvø
- Department of Pharmacy, University of Oslo, P.O. Box 1068, Blindern, 0316, Oslo, Norway
| | - Ørjan G Martinsen
- Department of Physics, University of Oslo, P.O. Box 1048, Blindern, 0316, Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068, Blindern, 0316, Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100, Copenhagen, Denmark.
| |
Collapse
|
6
|
Fashi A, Cheraghi M, Badiee H, Zamani A. An analytical strategy based on the combination of ultrasound assisted flat membrane liquid phase microextraction and a smartphone reader for trace determination of malondialdehyde. Talanta 2020; 209:120618. [DOI: 10.1016/j.talanta.2019.120618] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 12/02/2019] [Accepted: 12/03/2019] [Indexed: 12/12/2022]
|
7
|
Badiee H, Zanjanchi MA, Zamani A, Fashi A. Solvent stir bar microextraction technique with three-hollow fiber configuration for trace determination of nitrite in river water samples. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2019; 26:32967-32976. [PMID: 31512131 DOI: 10.1007/s11356-019-06336-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 08/26/2019] [Indexed: 06/10/2023]
Abstract
In this work, trace determination of nitrite in river water samples was studied using solvent stir bar microextraction system with three-hollow fiber configuration (3HF-SSBME) as a preconcentration step prior to UV-Vis spectrophotometry. The obtained results showed that the increase in the number of solvent bars can improve the extraction performance by increasing the contact area between acceptor and sample solutions. The extraction process relies on the well-known oxidation-reduction reaction of nitrite with iodide excess in acidic donor phase to form triiodide, and then its extraction into organic acceptor phase using a cationic surfactant. Various extraction parameters affecting the method were optimized and examined in detail. Detection limit of 1.6 μg L-1 and preconcentration factor of 282 can be attained after an extraction time of 8 min under the optimum conditions of this technique. The proposed method showed a linear response up to 1000 μg L-1 (r2 = 0.996) with relative standard deviation values less than 4.0%. The accuracy of the developed method was assessed using the Griess technique. Finally, the proposed method was successfully employed for quantification of nitrite in river water samples (Ghezelozan, Zanjan, Iran).
Collapse
Affiliation(s)
- Hamid Badiee
- Department of Chemistry, Faculty of Science, University of Guilan, University Campus 2, Rasht, Iran
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Zanjan, 45371-38791, Iran
| | - Mohammad Ali Zanjanchi
- Department of Chemistry, Faculty of Science, University of Guilan, University Campus 2, Rasht, Iran
- Department of Chemistry, Faculty of Science, University of Guilan, Rasht, 41335-1914, Iran
| | - Abbasali Zamani
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Zanjan, 45371-38791, Iran.
| | - Armin Fashi
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Zanjan, 45371-38791, Iran
| |
Collapse
|
8
|
A four-hollow fibers geometry of revolving solvent bar microextraction setup for the enrichment of trace ammonia. Talanta 2019; 199:170-177. [DOI: 10.1016/j.talanta.2019.02.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 02/02/2019] [Accepted: 02/04/2019] [Indexed: 01/04/2023]
|
9
|
Nasrollahi SS, Davarani SSH, Moazami HR. Impedometric investigation of salt effects on electromembrane extraction: Practical hints for pH adjustment. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2018.11.037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
10
|
Pedersen-Bjergaard S, Huang C, Gjelstad A. Electromembrane extraction-Recent trends and where to go. J Pharm Anal 2017; 7:141-147. [PMID: 29404030 PMCID: PMC5790682 DOI: 10.1016/j.jpha.2017.04.002] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Revised: 04/06/2017] [Accepted: 04/10/2017] [Indexed: 11/28/2022] Open
Abstract
Electromembrane extraction (EME) is an analytical microextraction technique, where charged analytes (such as drug substances) are extracted from an aqueous sample (such as a biological fluid), through a supported liquid membrane (SLM) comprising a water immiscible organic solvent, and into an aqueous acceptor solution. The driving force for the extraction is an electrical potential (dc) applied across the SLM. In this paper, EME is reviewed. First, the principle for EME is explained with focus on extraction of cationic and anionic analytes, and typical performance data are presented. Second, papers published in 2016 are reviewed and discussed with focus on (a) new SLMs, (b) new support materials for the SLM, (c) new sample additives improving extraction, (d) new technical configurations, (e) improved theoretical understanding, and (f) pharmaceutical new applications. Finally, important future research objectives and directions are defined for further development of EME, with the aim of establishing EME in the toolbox of future analytical laboratories.
Collapse
Affiliation(s)
- Stig Pedersen-Bjergaard
- School of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway.,Faculty of Health and Medical Sciences, School of Pharmaceutical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Chuixiu Huang
- School of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Astrid Gjelstad
- School of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| |
Collapse
|