1
|
Chen CJ, Williams ER. Variable Mixing with Theta Emitter Mass Spectrometry: Changing Solution Flow Rates with Emitter Position. Anal Chem 2023; 95:14777-14786. [PMID: 37729435 DOI: 10.1021/acs.analchem.3c02980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Two solutions can be rapidly mixed using theta glass emitters, with products measured using electrospray ionization mass spectrometry. The relative flow rates of the two emitter channels can be measured using different calibration compounds in each channel, or the flow rates are often assumed to be the same. The relative flow rates of each channel can be essentially the same when the emitters are positioned directly in front of the capillary entrance of a mass spectrometer, but the relative flow rates can be varied by up to 3 orders of magnitude by moving the position of the emitter tip ±1 cm in a direction that is perpendicular to the inner divider. Results of the emitter position on the different concentrations of reagents in the initially formed electrospray droplets are demonstrated through protein denaturation using a supercharging reagent as well as two different bimolecular reactions. The average charge state of myoglobin changed from +7.8 to +13.8 when 2.5% sulfolane was mixed with a 200 mM ammonium acetate solution containing the protein when the position of the emitter was scanned in front of the mass spectrometer inlet. The conversion ratio of a bimolecular reaction was changed from 0.98 to 0.04 with varying emitter positions. These results show that the relative flow rates must be carefully monitored because the droplet composition depends strongly on the position of the theta glass emitters. This method can be used to measure the dependence of reaction kinetics on different solution concentrations by using a single emitter and only two solutions.
Collapse
Affiliation(s)
- Casey J Chen
- Department of Chemistry, University of California, Berkeley, California 94720, United States
| | - Evan R Williams
- Department of Chemistry, University of California, Berkeley, California 94720, United States
| |
Collapse
|
2
|
Li Y, Mehari TF, Wei Z, Liu Y, Cooks RG. Reaction acceleration at air-solution interfaces: Anisotropic rate constants for Katritzky transamination. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4585. [PMID: 32686310 DOI: 10.1002/jms.4585] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 05/22/2020] [Accepted: 06/04/2020] [Indexed: 06/11/2023]
Abstract
To disentangle the factors controlling the rates of accelerated reactions in droplets, we used mass spectrometry to study the Katritzky transamination in levitated Leidenfrost droplets of different yet constant volumes over a range of concentrations while holding concentration constant by adding back the evaporated solvent. The set of concentration and droplet volume data indicates that the reaction rate in the surface region is much higher than that in the interior. These same effects of concentration and volume were also seen in bulk solutions. Three pyrylium reagents with different surface activity showed differences in transamination reactivity. The conclusion is drawn that reactions with surface-active reactants are subject to greater acceleration, as seen particularly at lower concentrations in systems of higher surface-to-volume ratios. These results highlight the key role that air-solution interfaces play in Katritzky reaction acceleration. They are also consistent with the view that reaction-increased rate constant is at least in part due to limited solvation of reagents at the interface.
Collapse
Affiliation(s)
- Yangjie Li
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Tsdale F Mehari
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Zhenwei Wei
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Yong Liu
- Department of Analytical Sciences, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| |
Collapse
|
3
|
Huang L, Fang M, Cupp-Sutton KA, Wang Z, Smith K, Wu S. Spray-Capillary-Based Capillary Electrophoresis Mass Spectrometry for Metabolite Analysis in Single Cells. Anal Chem 2021; 93:4479-4487. [PMID: 33646748 PMCID: PMC8323477 DOI: 10.1021/acs.analchem.0c04624] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Single-cell capillary electrophoresis mass spectrometry (CE-MS) is a promising platform to analyze cellular contents and probe cell heterogeneity. However, current single-cell CE-MS methods often rely on offline microsampling processes and may demonstrate low sampling precision and accuracy. We have recently developed an electrospray-assisted device, spray-capillary, for low-volume sample extraction. With the spray-capillary, low-volume samples (pL-nL) are drawn into the sampling end of the device, which can be used directly for CE separation and online MS detection. Here, we redesigned the spray-capillary by utilizing a capillary with a <15 μm tapered tip so that it can be directly inserted into single cells for sample collection and on-capillary CE-MS analysis. We evaluated the performance of the modified spray-capillary by performing single-cell microsampling on single onion cells with varying sample injection times and direct MS analysis or online CE-MS analysis. We have demonstrated, for the first time, online sample collection and CE-MS for the analysis of single cells. This application of the modified spray-capillary device facilitates the characterization and relative quantification of hundreds of metabolites in single cells.
Collapse
Affiliation(s)
- Lushuang Huang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Mulin Fang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Kellye A Cupp-Sutton
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Zhe Wang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Kenneth Smith
- Department of Arthritis and Clinical Immunology, Oklahoma Medical Research Foundation, Oklahoma City, Oklahoma 73104, United States
| | - Si Wu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| |
Collapse
|
4
|
Analysis and improvement of positioning reliability and accuracy of theta pipette configuration for scanning ion conductance microscopy. Ultramicroscopy 2021; 224:113240. [PMID: 33689886 DOI: 10.1016/j.ultramic.2021.113240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 02/02/2021] [Accepted: 02/27/2021] [Indexed: 11/21/2022]
Abstract
Scanning ion conductance microscopy (SICM) as an emerging non-contact scanning probe microscopy technique and featuring its strong in-situ detectability for soft and viscous samples, is increasingly used in biomedical and materials related studies. In SICM measurements, employing theta pipette as SICM probe to scan sample is an effective method to extend the applications of SICM for multi-parameter measurement. There are two crucial but still unclear issues that influence the reliability and accuracy of the usage of theta pipette in the SICM measurements, which are the safe feedback threshold and the horizontal measurement offset. In this work, aiming at the theta pipette configuration of SICM, we systematically investigated the two issues of the theta pipette by both finite element method (FEM) simulation and SICM experiments. The FEM analysis results show that the safe feedback threshold of the one side barrel of the theta pipette is above 99.5%, and the horizontal measurement offset is ~0.53 times of the inner radius of the probe tip. Based on this, we proposed an improved scanning method used by the theta pipette to solve the reliability and accuracy problems caused by the feedback threshold too close to the reference current (100%) and the measurement offset error at the tip radius level. Then through testing the polydimethylsiloxane (PDMS) samples with different embossed patterns with the improved method of SICM, we can conclude that the improved method can enhance the scanning reliability by adding the double barrels approaching process and increase the positioning accuracy by compensating an offset distance. The theoretical analysis and the improved scanning method in this work demonstrate more property and usage details of the theta pipette, and further improve the reliability and accuracy of the diversified multifunctional applications of the theta pipette for SICM to meet the increasingly complex and precise research needs.
Collapse
|
5
|
Controllable fabrication of pico/femtoliter pipette sampling probes and visual sample volume determination. Talanta 2020; 218:121096. [DOI: 10.1016/j.talanta.2020.121096] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 04/25/2020] [Accepted: 04/27/2020] [Indexed: 12/11/2022]
|
6
|
Zheng F, Zhang S, Mo J, Yi H, Zhang S, Yu H, Lin K, Sha J, Chen Y. Ion Concentration Effect on Nanoscale Electrospray Modes. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2000397. [PMID: 32485055 DOI: 10.1002/smll.202000397] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 03/31/2020] [Accepted: 03/31/2020] [Indexed: 06/11/2023]
Abstract
The phenomena and mechanism of electrospray modes in nanoscale are investigated from experiments and molecular dynamics simulations. It is found that the ionic concentration plays a crucial role in determining the dripping or the jetting modes in a nanoscale electrospray system. Molecular dynamics simulations uncover that the two modes are caused by the competition between the electric field stress and surface tension, which is similar to the mechanism in a macroscale electrospray system. However, in a nanoscale electrospray system, the two competing forces of the electric field stress and surface tension are more sensitive to the ion distributions than that in a macroscale electrospray system, in which the applied voltage and pressure dominate. With the decrease of the nozzle diameter to nanoscale, the ions not only affect the local electric field stress, but also destroy the hydrogen bonds among water molecules, which lead to that the ion concentration becomes a dominant factor in determining the electrospray modes in nanoscale. The discovery provides a novel method to control nanoscale electrospray modes, which may find potential applications for mass spectrometry, film deposition, and electrohydrodynamic printing.
Collapse
Affiliation(s)
- Fei Zheng
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Shuai Zhang
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Jingwen Mo
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Haojie Yi
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Shizhao Zhang
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Hongyang Yu
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Kabin Lin
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Jingjie Sha
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| | - Yunfei Chen
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, P. R. China
| |
Collapse
|
7
|
Huang L, Wang Z, Cupp-Sutton KA, Smith K, Wu S. Spray-Capillary: An Electrospray-Assisted Device for Quantitative Ultralow-Volume Sample Handling. Anal Chem 2020; 92:640-646. [PMID: 31793760 PMCID: PMC7558432 DOI: 10.1021/acs.analchem.9b04131] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The analysis of low-volume samples provides valuable insight into complex biological systems. However, the proteomic and metabolomic analysis of low-volume samples remains challenging due to the lack of simple, efficient, and reproducible microsampling techniques. We have developed an electrospray-assisted device for quantitative low-volume sample extraction, referred to here as "Spray-Capillary". Stable electrospray was achieved through a chemically etched tip from a long (e.g., 50 cm) capillary with a conductive sheath flow. This electrospray provided the driving force to quantitatively draw low-volume samples into the capillary. We evaluated the precision and accuracy of sample injection volumes using our spray-capillary as the electrospray voltage, capillary ID, and column length were varied. Our results demonstrate that spray-capillary allows for reproducible and quantitative microsampling with low injection flow rates (as low as 15 pL/s). Furthermore, spray-capillary can be directly coupled with capillary zone electrophoresis (CZE) for separation. Overall, spray-capillary is a simple microsampling device that holds great potential for high-throughput quantitative omics analysis of ultralow-volume samples.
Collapse
Affiliation(s)
- Lushuang Huang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Zhe Wang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Kellye A. Cupp-Sutton
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Kenneth Smith
- Department of Arthritis and Clinical Immunology, Oklahoma Medical Research Foundation, Oklahoma City, Oklahoma 73104, United States
| | - Si Wu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| |
Collapse
|
8
|
Saha-Shah A, Esmaeili M, Sidoli S, Hwang H, Yang J, Klein PS, Garcia BA. Single Cell Proteomics by Data-Independent Acquisition To Study Embryonic Asymmetry in Xenopus laevis. Anal Chem 2019; 91:8891-8899. [PMID: 31194517 PMCID: PMC6688503 DOI: 10.1021/acs.analchem.9b00327] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Techniques that allow single cell analysis are gaining widespread attention, and most of these studies utilize genomics-based approaches. While nanofluidic technologies have enabled mass spectrometric analysis of single cells, these measurements have been limited to metabolomics and lipidomic studies. Single cell proteomics has the potential to improve our understanding of intercellular heterogeneity. However, this approach has faced challenges including limited sample availability, as well as a requirement of highly sensitive methods for sample collection, cleanup, and detection. We present a technique to overcome these limitations by combining a micropipette (pulled glass capillary) based sample collection strategy with offline sample preparation and nanoLC-MS/MS to analyze proteins through a bottom-up proteomic strategy. This study explores two types of proteomics data acquisition strategies namely data-dependent (DDA) and data-independent acquisition (DIA). Results from the study indicate DIA to be more sensitive enabling analysis of >1600 proteins from ∼130 μm Xenopus laevis embryonic cells containing <6 nL of cytoplasm. The method was found to be robust in obtaining reproducible protein quantifications from single cells spanning the 1-128-cell stages of development. Furthermore, we used micropipette sampling to study intercellular heterogeneity within cells in a single embryo and investigated embryonic asymmetry along both animal-vegetal and dorsal-ventral axes during early stages of development. Investigation of the animal-vegetal axis led to discovery of various asymmetrically distributed proteins along the animal-vegetal axis. We have further compared the hits found from our proteomic data sets with other studies and validated a few hits using an orthogonal imaging technique. This study forms the first report of vegetal enrichment of the germ plasm associated protein DDX4/VASA in Xenopus embyos. Overall, the method and data presented here holds promise to enable important leads in developmental biology.
Collapse
Affiliation(s)
- Anumita Saha-Shah
- Epigenetics Institute, Department of Biochemistry and Biophysics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Melody Esmaeili
- Cell and Molecular Biology Graduate Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Simone Sidoli
- Epigenetics Institute, Department of Biochemistry and Biophysics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Hyojeong Hwang
- Department of Comparative Biosciences, University of Illinois at Urbana-Champaign, 2001 South Lincoln Avenue, 3411 Veterinary Medicine Basic Sciences Building, Urbana, IL 61802, USA
| | - Jing Yang
- Department of Comparative Biosciences, University of Illinois at Urbana-Champaign, 2001 South Lincoln Avenue, 3411 Veterinary Medicine Basic Sciences Building, Urbana, IL 61802, USA
| | - Peter S. Klein
- Cell and Molecular Biology Graduate Group, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Department of Medicine (Hematology-Oncology), Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Benjamin A. Garcia
- Epigenetics Institute, Department of Biochemistry and Biophysics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA
| |
Collapse
|
9
|
Baker LA, Jagdale GS. On the intersection of electrochemistry and mass spectrometry. CURRENT OPINION IN ELECTROCHEMISTRY 2019; 13:140-146. [PMID: 33981910 PMCID: PMC8112614 DOI: 10.1016/j.coelec.2018.12.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The application of nanopipettes, developed first as a tool for electrochemistry and electrophysiology, as tools for mass spectrometry is considered. Recent examples of advances in electrospray ionization and sampling for mass spectrometry with nanopipettes is discussed. These examples show a scientific intersection that is ripe for further development.
Collapse
Affiliation(s)
- Lane A Baker
- Indiana University, Department of Chemistry, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA
| | - Gargi S Jagdale
- Indiana University, Department of Chemistry, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA
| |
Collapse
|
10
|
Duncan KD, Fyrestam J, Lanekoff I. Advances in mass spectrometry based single-cell metabolomics. Analyst 2019; 144:782-793. [DOI: 10.1039/c8an01581c] [Citation(s) in RCA: 131] [Impact Index Per Article: 26.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Single cell metabolomics using mass spectrometry can contribute to understanding biological activities in health and disease.
Collapse
|
11
|
Yin R, Prabhakaran V, Laskin J. Quantitative Extraction and Mass Spectrometry Analysis at a Single-Cell Level. Anal Chem 2018; 90:7937-7945. [PMID: 29874047 DOI: 10.1021/acs.analchem.8b00551] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Ruichuan Yin
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Venkateshkumar Prabhakaran
- Physical Sciences Division, Pacific Northwest National Laboratory, Richland Washington 99352, United States
| | - Julia Laskin
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
12
|
Chen LC, Yoshimura K, Ninomiya S, Takeda S, Hiraoka K. Towards Practical Endoscopic Mass Spectrometry. ACTA ACUST UNITED AC 2017; 6:S0070. [PMID: 28852605 DOI: 10.5702/massspectrometry.s0070] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 06/01/2017] [Indexed: 12/20/2022]
Abstract
In this paper, we briefly review the remote mass spectrometric techniques that are viable to perform "endoscopic mass spectrometry," i.e., in-situ and in-vivo MS analysis inside the cavity of human or animal body. We also report our experience with a moving string sampling probe for the remote sample collection and the transportation of adhered sample to an ion source near the mass spectrometer. With a miniaturization of the probe, the method described here has the potential to be fit directly into a medical endoscope.
Collapse
Affiliation(s)
- Lee Chuin Chen
- Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi
| | - Kentaro Yoshimura
- Department of Anatomy and Cell Biology, Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi
| | - Satoshi Ninomiya
- Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi
| | - Sen Takeda
- Department of Anatomy and Cell Biology, Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi
| | - Kenzo Hiraoka
- Clean Energy Research Center, University of Yamanashi
| |
Collapse
|
13
|
Chen LC, Naito T, Tsutsui S, Yamada Y, Ninomiya S, Yoshimura K, Takeda S, Hiraoka K. In vivo endoscopic mass spectrometry using a moving string sampling probe. Analyst 2017; 142:2735-2740. [DOI: 10.1039/c7an00650k] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A novel moving string sampling probe and sample transportation system for performing in situ and in vivo endoscopic MS.
Collapse
Affiliation(s)
- Lee Chuin Chen
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Kofu
- 400-8511 Japan
| | - Tsubasa Naito
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Kofu
- 400-8511 Japan
| | - Satoru Tsutsui
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Kofu
- 400-8511 Japan
| | - Yuki Yamada
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Kofu
- 400-8511 Japan
| | - Satoshi Ninomiya
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Kofu
- 400-8511 Japan
| | - Kentaro Yoshimura
- Department of Anatomy and Cell Biology
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Japan
| | - Sen Takeda
- Department of Anatomy and Cell Biology
- Interdisciplinary Graduate School of Medicine and Engineering
- University of Yamanashi
- Japan
| | - Kenzo Hiraoka
- Clean Energy Research Center
- University of Yamanashi
- Kofu
- 400-8511 Japan
| |
Collapse
|